1 PC CTROL COMMAND REFERENCE FOR THE TS-80HX/ SAT TRANSCEIVER 00//

2 PC CTROL COMMAND ABOUT THIS REFERENCE All descriptions in this PC CTROL COMMAND reference are for the users convenience only. KENWOOD will not support or warrantee this documentation in any way. HARDWARE DESCRIPTI The TS-80 transceiver uses a full-duplex, asynchronous, serial interface for communicating through the male 9-pin D-sub connector. Each data is constructed with start bit, 8 data bits, and stop bit (800 bps must be configured as stop bits). No parity is used. The pinout and the pin functions of the COM connector on the transceiver are shown below: COM COM Pin Name Pin No. (Ref.: Computer) NC RXD TXD NC 5 GND 6 NC 7 RTS 8 CTS 9 NC Front view COM 9 Function (Ref.: Transceiver) Transmit data Receive data Signal ground Receive enable Transmit enable I/O Output Input Input Output RXD: Transmit data is serial data transferred from the transceiver to the computer. TXD: Receive data is serial data transferred from the computer to the transceiver. GND: Signal ground pin RTS: This signal is applied to the transceiver. It is used to inhibit transmit data from the transceiver when the computer is not ready to receive data. Transmit data is inhibited when the level is low. CTS: This signal is applied from the transceiver. It is used to inhibit transmit data from the computer when the transceiver is not ready to receive data. Transmit data is stopped when the level is low. CTROL OPERATI Most computers handle data in the form of bits and bytes. A bit is the smallest piece of information that a computer can handle. A byte is composed of eight bits. This is the most convenient form for most computer data. This data may be sent in the form of either serial or parallel data strings. The parallel method is faster but more complicated, while the serial method is slower and requires less complicated equipment. The serial form is, therefore, a less expensive alternative. Serial data transmission uses time-division methods over a single line. Using a single line also offers the advantage of reducing the number of errors due to line noise. Only lines are required theoretically for control of the transceiver via the computer: Transmit data Receive data Ground From a practical standpoint, it is also necessary to incorporate some means of controlling when this data transfer will occur. The computer and transceiver cannot be allowed to send data at the same time! The required control is achieved by using the RTS and CTS lines. To interface between the TS-80 transceiver and a PC, use a commercially available cable with a DB-9 female connector at each end. Each connector pin must be connected to the same pin number at the other end (a straight cable). To control the transceiver from a PC, utilize the general purpose terminal program to send commands to the tranceiver. The transceiver responds the command accordingly. For example, the transceiver is placed into the transmit mode whenever the character string TX is sent from the computer. The character string TX is called a PC control command. You can further develop or create a script of the commands using a macro function of the terminal program. Kenwood also provides the remote control program, ARCP-80 at our Web site. You can download the program for free and try it out on your PC. Access amateur.html and follow the instructions.

3 PC CTROL COMMAND COMPUTER CTROL COMMANDS A computer control command is composed of an alphabetical command, various parameters, and the terminator that signals the end of the control command. EXAMPLE: Command to set VFO A to 7 MHz FA Terminator Parameters Alphabetical command Commands can be classified as shown below: Computer control commands Input command (Input to the transceiver) Output command (From the transceiver) command (s a particular condition) command (s an answer) command (Transmits a condition) For example, note the following in the case of the FA command (Frequency of VFO A): To set the frequency to 7 MHz, the following command is sent from the computer to the transceiver: FA ( command) To read the frequency of VFO A, the following command is sent from the computer to the transceiver: FA ( command) When the command above has been sent, the following command is returned to the computer: FA ( command) Note: Do not use the control characters 00 to Fh since they are either ignored or cause a? answer. Program execution may be delayed while turning the Tuning control rapidly. Alphabetical Commands A command consists of alphabetical characters. You may use either lower or upper case characters. The commands available for this transceiver are listed in the PC Control Command Tables from page. Parameters Parameters are used to specify information necessary to implement the desired command. The parameters to be used for each command are predetermined. The number of digits assigned to each parameter is also predetermined. Refer to the Computer Control Commands and the PC Control Command Tables to configure the appropriate parameters. When configuring parameters, be careful not to make the following mistakes. (correct parameter: IS+00 ) IS00 Not enough parameters specified (No direction given for the IF shift) IS+0 Not enough digits (Only three frequency digits given) IS + 00 Unnecessary characters between parameters IS+000 Too many digits (Five frequency digits given) Note: If a particular parameter is not applicable to this transceiver, the parameter digits should be filled using any character except the ASCII control codes (00 to Fh) and the terminator (). Terminator To signal the end of a command, it is necessary to use a semicolon (). The digit where this special character must appear differs depending on the command used. Error Messages In addition to the command, the transceiver can send the following error messages. Error Message? E O Reason for Error Command syntax was incorrect. Command was not executed due to the current status of the transceiver (even though the command syntax was correct). Note: Occasionally this message may not appear due to microprocessor transients in the transceiver. A communication error occurred such as an overrun or framing error during a serial data transmission. Receive data was sent but processing was not completed.

4 PC CTROL COMMAND TABLES PC CTROL COMMAND S ets or reads the internal antenna tuner status. AC 0: RX-AT THRU : RX-AT IN A C P 0: TX-AT THRU : TX-AT IN A C 0: Stop tuning ()/ Tuning is stopped () : Start tuning ()/ Tuning is active () AG A C P S ets or reads the AF gain. 0: A G P 000 A G A G P Always 0 for the TS-80. (min.) ~ 55 (max.) S ets or reads the Auto Information (AI) function /. AI 0: AI : Only old AI format is A I : Only extended AI format is : Both formats are When the extended AI format is selected, the transceiver A I automatically sends the parameters. When the old AI is and the IF parameters change, the transceiver sends the IF command every.5 seconds. When the transceiver is turned, the AI parameter A I becomes 0. AN S elects the antenna connector ANT/ ANT. : Selects ANT : Selects ANT A N A N A N S ets or reads the Auto Mode function parameters. AS 0: Always 0 for the TS-80. A S Frequency in Hz (-digit). P 0: Reserved : LSB : USB A S P : CW : FM 5: AM A S 6: FSK 7: CWR (CW Reverse) : Reserved P 9: FSR (FSK Reverse) ~ : HF ~ 50 MHz band ( points) Unused digit(s) must be 0.

5 PC CTROL COMMAND BC S ets or reads the Beat Canceller function status. 0: Beat Canceller : Beat Canceller (BC) : Beat Canceller (BC) B C B C B C BD M oves down the frequency band. None B D BU M oves up the frequency band. None B U BY CA R eads the busy signal status. Transceiver status 0: Not busy : Busy B Y Sub-receiver status (Not applicable for the TS-80) 0: Always 0 for TS-80. B Y P S ets and reads the CW Auto Zero-beat function status. 0: Cancels CW Auto Zero-beat function/ Not active : Activates CW Auto Zero-beat function/ Active C A C A C A

6 CH Move the control. current VFO frenquency step up, using the MULTI C H 0: Move the MULTI control step up : Move the MULTI control step down In VFO mode, CH command overrides mode of the TS-80 transceiver. PC CTROL COMMAND the MHz Up/ Down CN CT DL DN S ets and reads the CTCSS tone number. 00 ~ C N C N C N Refer to page of the TS-80 instruction CTCSS tone numbers and frequencies. S ets and reads the CTCSS function status. 0: CTCSS function : CTCSS function C T C T C T S ets and reads the Digital Noise Limiter (DNL) function status. D L 5 P : DNL function : DNL function D L : DNL Level 0: DNL Level 0: DNL Level D L P E mulates the microphone DWN key. 00 ~ 99 D N manual for the If no parameter is specified, the command is interpreted as step down. In Memory mode and Quick Memory mode, the command without a parameter is treated as a Memory channel down command. With parameters, it is treated as the frequency down command. 5

7 PC CTROL COMMAND EX S ets or reads the Extension Menu. 000 ~ 060: Menu No. E X P5 0 00: Always 00 for the TS-80 0: Always 0 for the TS-80 P 5 0: Always 0 for the TS-80 E X P 9 P5 A string of characters (Variable length) Normally -digit for the TS-80. Menu No., 5 and 8 ~ 5 use -digit parameters. E X P P 5 Command example: Display brightness EX (Display illumination ). EX (Display brightness level ). 6

8 PC CTROL COMMAND Menu No. Function 000 Display brightness 00 Key illumination 00 Auto Mode operation EX command parameter P5 0 Over 00 Tuning control adjustment rate (Hz) Tuning with Tuning control in FM mode Rounds off VFO frequencies changed by using the MULTI control 9 khz frequency step size for the MULTI control in AM mode on the AM broadcast band Tunable () or fixed () memory channel frequencies 008 Program scan partially slowed 009 Slow down frequency Program scan 0 Program scan hold 0 Scan resume method 0 Beep output level 0 TX sidetone volume range for the 0 VGS- message playback volume 05 VGS- announcement volume 06 VGS- announcement speed 07 Use CW IF filter for SSB reception 08 DSP RX equalizer 09 DSP TX equalizer 00 DSP TX filter bandwidth for SSB or AM 0 Fine transmission power tuning 0 Time-out timer 0 Transverter frequency display 0 05 Output power Transverter TX hold tuning when adjustment for AT completes the 06 In-line AT while receiving (Hz) to co Hb Hb Hb Hb.0. FP bb bb c U FP bb bb c U (minutes) 07 Control method for the external AT At At Linear amplifier control delay for HF band Linear amplifier control delay for 50 MHz band 00 Constant recording 0 Repeat the playback 0 Interval time playback for repeating the 0 Keying priority over playback 0 0 CW RX pitch/ TX sidetone frequency CW keying dot, dash weight ratio 06 Reverse CW keying auto weight ratio 07 Bug key function AUTO ~ 60 (in steps of s) ~ 00 (in steps of 50) ~.0 (in steps of 0.) 7

9 PC CTROL COMMAND Menu No. Function 08 Swap dot and dash paddle position 09 Auto CW TX in SSB mode 00 Frequency correction SSB to CW for changing EX command parameter P5 0 Over 0 FSK shift (Hz) 0 FSK keying polarity 0 FSK tone frequency 75 5 (Hz) 0 Mic gain for FM Filter bandwidth for Data communications AF input level for Data communications AF output level for Data communications 08 Remote Control panel PF key 09 Microphone PF key 050 Microphone PF key 05 Microphone PF key 05 Microphone PF key Split frequency transfer in master/ slave operation Permit to write the transferred Split frequencies to the target VFOs 055 TX inhibit ~ 99 (-digit) Refer to page 6 of the TS-80 instruction manual for the numbers and functions. 056 COM port communication speed (bps) 057 DTS polarity 058 Busy lockout (TX) 059 APO (Auto Power Off) function 060 Transmit with the DATA terminal audio input on the (minutes) 8

10 PC CTROL COMMAND FA R eads and sets the VFO A frequency. Specify the frequency in Hz (-digit). For example, for.95 MHz. F A must be The blank digits F A F A FB R eads and sets the VFO B frequency. Specify the frequency in Hz (-digit). For example, for.95 MHz. F B must be The blank digits F B F B FR FS S elects or reads the VFO or M.CH mode of the receiver. F R P : VFO A : VFO B : M.CH F R F R When =, the FT command becomes invalid. S elects or reads the Fine Tuning function status. 0: Fine Tuning function : Fine Tuning function F S F S F S 9

11 PC CTROL COMMAND FT S elects or reads the VFO or M.CH mode of the transmitter. 0: VFO A : VFO B : M.CH F T F T F T When = is selected for the command becomes invalid. FR command, the FT S elects or reads the DSP filtering bandwidth. FW 0000 ~ 9999 (in Hz) CW: 0050, 0080, 00, 050, 000, 000, 000, 0500, 0600, F W 00, 000 FSK: 050, 0500, 00, 500 SSB/FM/AM: 0000=Normal, 000=NAR, 000=NAR F W Use the SL or SH command to change the slope tune filter frequencies. F W GT S elects or reads the AGC constant status. G T 5 P : 00: Fast 00: Slow G T G T The GT command cannot be used in FM mode. The transceiver responds with spaces when the GT command is used in FM mode. ID R eads the transceiver ID number. 00: TS-80 I D I D

12 IF R etrieves the transceiver status. Specify the frequency in Hz (-digit). The blank digits must be 0. 5 spaces for the TS-80. R IT/ XIT frequency ± 9990 in Hz 0: RIT, : RIT P5 I F 0: XIT, : XIT P6: Always P7: I F Memory channel number (00 ~ 99). P8 0: RX, : TX P9 Operating mode. 0 See FR and FT commands Scan status. Refer to the SC command. P5 P6 P7 P7 P8 P9 0: Simplex operation, : Split operation :, : TE, : CTCSS Tone number (00 ~ ). 0 P 5 5 A space character for the TS-80. IS KS S ets and reads the IF SHIFT function status. I S P or (a space): Plus shift : Minus shift 0000 ~ 0 I S I S P S ets and reads the CW electric keyer s keying speed. 0 (min.) ~ 060 (max.) [in WPM] K S K S K S PC CTROL COMMAND 0 for the TS-80 (Memory channel bank number). Refer to the MD commands for details. Refer to the TN and CN command.

13 PC CTROL COMMAND KY LK C onverts the characters into Morse code. 0: Character buffer is available : Character buffer is not available K Y ( command only. A space must command.) Enter characters and numbers. Available characters are: ABCDEFGHIJKLMNOPQRSTUVWXYZ " ' ( ) * +,. / : =? P Special characters: The following ASCII special CW codes. BT=[, AR=_, AS=<, K Y K Y be used for the (space) characters can be used in place of the HH=#, SK=>, KN=], BK=\, SN=% The fixed -byte length is used for the parameter. (space) character must be used for the unused characters. These space characters will not be converted. If all parameter characters are spaces, the transceiver stops sending the message. S ets and reads the key lock function status. L K P : Frequency lock function : Frequency lock function 0: Tuning control lock function : Tuning control lock function L K L K P S ets and reads the VGS- or electric keyer recording status. LM ~ : CH (Recording Channel) number L M P 0: Stop recording ( command only) 0: Recording function is inactive : y for recording : Start recording (Busy L M 000 ~ 060: Remaining recording (Voice mode) 000 ~ 0: Recorded message L M P (CW) MC R ecalls or reads the Memory channel. 0: M C P 00 M C M C P status while recording) time in seconds capacity as a percentage Always 0 for the TS-80 (Memory bank number). ~ 99: Channel number R ecalls or reads the operating mode status. MD 0: No mode (Not used for the TS-80) : LSB M D : USB : CW : FM 5: AM M D 6: FSK 7: CWR (CW Reverse) 8: Tune (Not used for the TS-80) M D 9: FSR (FSK Reverse)

14 PC CTROL COMMAND MF MG ML S ets or reads Menu A or B. 0: Menu A : Menu B M F M F M F S ets or reads the Microphone gain status. 000 (min.) ~ 0 (max.) M G M G M G S ets or reads the TX Monitor function output level. 000: TX Monitor function 00 (min.) ~ 009 (max.) M L M L M L MR R eads the Memory channel data. 0: RX frequency, : TX frequency Always 0 for the TS ~ 99: Memory channel number Frequency in Hz (-digit). P5 Mode. M R P P6 Refer to the MD command. Lockout status. 0: Lockout, : Lockout. P7 0:, : TE, : CTCSS M R P8 Tone Number. Refer to page P5 9 P6 0 P7 P9 CTCSS tone number. Refer to the CN command. 0 Always 000 for the TS Always 0 for the TS-80. Always 0 for the TS-80. P8 P8 P9 P Always for the TS-80. Step size. Refer to the ST command. 5 Always 0 for the TS Memory name. A maximum of 8 characters P 6 Memory channel 90 ~ 99: =0 (start frequency), = (end frequency)

15 PC CTROL COMMAND MW S tore the data to the Memory channel. 0: RX frequency, : TX frequency Always 0 for the TS-80. M W 00 ~ 99: Memory channel number Frequency in Hz (-digit). P5 P6 P7 P5 Mode. Refer to the MD command. P6 Lockout status. 0: Lockout, : Lockout P7 0:, : TE, : CTCSS P8 P8 P9 P P8 Tone Number. Refero to the TN command P9 CTCSS tone number. Refer to the CN command. 0 Always 000 for the TS Always 0 for the TS P 6 Always 0 for the TS-80. Always for the TS-80. Step size. Refer to the ST command. 5 Always 0 for the TS Memory name. A maximum of 8 characters. Memory channel 90 ~ 99: =0 (start frequency), = (end frequency) NB NL NR S et or reads the Noise Blanker (NB) function status. 0: Noise Blanker (NB) function : Noise Blanker (NB) function N B N B N B S et or reads the NB (Noise Blanker) level. 00 (min.) ~ 0 (max.) N L N L N L 000 is treated as ~ 999 are treated as 0. S ets or reads the Noise Reduction (NR) function status. 0: Noise Reduction (NR) : Noise Reduction (NR) : Noise Reduction (NR) N R N R N R

16 R eads the IF filter availability. OP 0: YF-7SN (.8 khz) is not installed. : YK-7SN (.8 khz) is installed. 0: YF-7C (500 Hz) is not installed. : YF-7C (500 Hz) is installed. O P 0: YF-7CN (70 Hz) is not installed. : YF-7CN (70 Hz) is installed. PA O P P S ets or reads the pre-amplifier function status. P A P : Pre-amplifier : Pre-amplifier ( only) 0: Always 0 for the TS-80 P A P A P S ets or reads the VGS- or electric keyer playback status. PB 0: Stop playing back : Playback CH P B : Playback CH : Playback CH ~ Playback queing P B 0: Inactive : Playback CH : Playback CH P B P : Playback CH PC PL a message. buffer status. S ets or reads the output power. TS-80HX 005 ~ 00 (in steps of ) for SSB/ CW/ P C 005 ~ 050 (in steps of ) for AM mode TS-80SAT 005 ~ 0 (in steps of ) for SSB/ CW/ P C 005 ~ 05 (in steps of ) for AM mode P C S ets and reads the Speech Processor input/ output level. P L P 9 Input level: 000 (min.) ~ 0 (max.) Output level: 000 (min.) ~ 0 (max.) P L P L P PC CTROL COMMAND FM/ FSK mode FM/ FSK mode 5

17 PC CTROL COMMAND PR PS S ets or reads the Speech Processor function /. 0: Speech Processor : Speech Processor P R P R P R S ets or reads the Power / status. 0: Power (The : Power P S 9: Power (The P S P S transceiver s CPU is in active mode.) transceiver s CPU is in sleep mode.) When the transceiver is turned and =9, a dummy data must be sent to the TS-80 to wake up the CPU. For example, send a string of PS to turn the transceiver. If you use a hyper terminal program that comes with Windows to control the transceiver, disable the flow control in the program. QI S tore the settings in the Quick Memory. None Q I QR RA S ets or reads the Quick Memory channel data. Q R P : Quick Memory : Quick Memory 0 ~ 9: Quick Memory channel number Q R Q R P S ets or reads the Attenuator function status. R A P : ATT 0: ATT 00: Always 00 for the TS-80. R A R A P 6

18 PC CTROL COMMAND RC C lears the RIT offset frequency. None R C RD Moves the RIT offset frequency down. Speeds up the scan speed in Scan mode. R D R D R D P ~ (the offset frequency in Hz) ~ 9: Scan speed When Scan is : If no parameter is specified, the frequency goes down step. When Scan is : RD to read the current scan speed. RDnnnnn (nnnnn = Any number) to increase the scan speed by step. RG RL S ets or read the RF gain status. 000 (min.) ~ 0 (max.) R G R G R G S ets or reads the Noise Reduction level. When the NR is : 00 = AUTO, 0 ~ 09 When the NR is : 00 ( ms) ~ 09 (0 ms) ms R L R L R L S ets or reads the Meter function. RM Selects the meter scale 0: Unselected (Not available for the TS-80) R M : SWR : COMP : ALC R M Meter value in dots: 0000 ~ 00 R M P in steps of 7

19 PC CTROL COMMAND RS RT R eads the transceiver status. 0: Normal : The transceiver is busy configuring the various settings, such as M.SCR mode, Menu mode, or direct frequency entry mode. R S R S S ets or reads the RIT function status. 0: RIT function : RIT function R T R T R T RU Moves the RIT offset frequency up. Slows down the scan speed in Scan mode. R U R U R U P ~ (the offset frequency in Hz) ~ 9: Scan speed When Scan is : If no parameter is specified, the frequency increases by step up. When Scan is : RU to read the current scan speed. RUnnnnn (nnnnn = Any number) to decrease the scan speed by step. RX S ets the receiver function status. 0: Always 0 for the TS-80 R X R X S ets or reads the SCAN function status. SC / 0: Scan : Scan : Tone Scan S C 5: CTCSS Scan 0: Normal Scan : Program Scan (Slow down) S C When = parameter is sent, the transceiver performs either Program Scan or VFO Scan depending on the VFO mode. In Memory Recall mode, it performs either Group S C P Scan or All-Channel Scan depending on the transceiver status. 8

20 SD SH SL SM SQ S ets or reads the CW Break-in time delay ~ 00 ms (in steps of 0000 is FBK (Full Break-in) S D S D S D 50 ms) PC CTROL COMMAND S ets or reads the DSP filter settings. 00 ~ SSB/ FM (Hz) S H 00: 00, 0: 00, 0: 00, 0: 600, 0: 800, 05: 000, 06: 00, 07: 00, 08: 600, 09: 800, : 000, : 00 S H : 000, : 5000 AM (Hz) 00: 500, 0: 000, 0: 000, 0: 5000 S H When Menu the filter. 00: 00 No. 5 is, specify the center frequency for Hz, 0: 500 Hz, 0: Hz S ets or reads the DSP filter settings. S L P ~ SSB/ FM (Hz) 00: 0, 0: 50, 0: 0, 0: 00, 0: 00, 05: 00, 06: 500 S L : 600, 08: 700, 09: 800, : 900, : 00 AM (Hz) 00: 0, 0: 0, 0: 00, 0: 500 S L When Menu No. 5 is, specify the filter bandwidth. 00: 50, 0: 0, 0: 50, 0: 500, 0: 00, 05: 500, 06: 00 (Hz) R eads the S-meter status. 0: Always 0 for the TS-80. Meter readings 0000 ~ 000 S M S M P S ets and reads the squelch level. S Q 5 6 P : Always 0 for the TS-80. Squelch level 000 ~ 55 S Q S Q P 9

21 PC CTROL COMMAND SR R esets the transceiver. : VFO reset : Full reset S R SS S ets or reads the Program Scan pause frequency. 0 ~ 9: Memory Channel number for the Program Scan (0: Memory Channel 90 ~ 9: Memory channel 99) S S 5 P ~ : Slow down frequency (5 locations) Slow down frequency (-digit) S S P S S P If the specified Memory channel is empty, the command becomes invalid. The parameter must be specified sequencially from 0. If the previous parameter is not specified, the parameter cannot be accepted. The slow down frequency parameter must be within the frequency range of each Memory channel. ST S ets or reads the MULTI control frequency steps. S T P SSB/ CW/ FSK mode: 00 ~ 0 00: 0.5 khz, 0: khz, 0:.5 khz, 0: 5 khz, 0: khz AM/ FM mode: 00 ~ 09 S T : 5 khz, 0: 6.5 khz, 0: khz, 0:.5 khz, 0: 5 khz, 05: 0 khz, 06: 5 khz, 07: 0 khz, 08: 50 khz, 09: 0 khz S T SU s or reads the Program Scan (MGROUP) selection status. (VGROUP)/ Memory Group S U P5 P6 P7 P P9 0 P S U S U P5 P6 P7 P P9 0 P 0: Program Scan Group (VGROUP) : Memory Group (MGROUP) Group 0. 0: Unselected, ~ 9: Selected Group. 0: Unselected, ~ 9: Selected Group. 0: Unselected, ~ 9: Selected P5 Group. 0: Unselected, ~ 9: Selected P6 Group. 0: Unselected, ~ 9: Selected P7 Group 5. 0: Unselected, ~ 9: Selected P8 Group 6. 0: Unselected, ~ 9: Selected P9 Group 7. 0: Unselected, ~ 9: Selected 0 Group 8. 0: Unselected, ~ 9: Selected Group 9. 0: Unselected, ~ 9: Selected 0

22 PC CTROL COMMAND SV E xecute the Memory Transfer function. No parameter S V TN TO TS TX S ets or reads the Tone frequency number. 00 ~ T N T N T N Refer to page of the TS-80 instruction Tone numbers and frequencies. S ets or reads the Tone function /. 0: Tone function : Tone function T O T O T O S ets or reads the TF-SET function status. 0: TF-SET function : TF-SET function T S T S T S S ets the transceiver in TX mode. T X P : Normal (SEND) transmission using MIC input : DTS transmission using ANI input : TX Tune transmission If no parameter is specified, =0 is used. T X P Always 0 for the TS-80. manual for the

23 PC CTROL COMMAND TY S ets or reads the microprocessor fimware type. Reserved 0: TS-80HX (00 T Y T Y P W) : TS-80SAT (0 W + AT) : Japanese 50 W type : Japanese 0 W type UL D etects the PLL unlock status. 0: Lock : Unlock U L UP E mulates the microphone UP key. 00 ~ 99 U P If no parameter is specified, the command is interpreted as step up. In Memory mode and Quick Memory mode, commands without parameters are treated as Memory channel up commands. With parameters, they are treated as frequency up commands. VD VG S ets or reads the VOX delay time ~ 000 ms (in steps of 50) V D V D V D S ets or reads the VOX GAIN. 000 ~ 009 V G V G V G

24 VR E mulates the VOICE or VOICE key. V R P : Normal : VOICE : VOICE : Disable the Voice Guide function PC CTROL COMMAND After = is sent to the transceiver, = and cannot be used. To use the = and parameters, first send =0 to reset the status. When the transceiver is turned, it resets to =0. VV E qualizes VFO A and VFO B settings. None V V VX S ets or reads the VOX function status. 0: VOX function : VOX function V X V X V X XI s the transmission frequency step size. frequency, mode and MULTI control X T X T The frequency in for.95 MHz. Transmission mode. MULTI control frequency command parameters. Hz (-digit). For example, Refer to the MD command parameters. step size. Refer to the ST P

25 PC CTROL COMMAND XO s and reads the transverter mode. offset direction and frequency for the X O P X O X O P Offset direction. 0: Plus diretion : Minus direction Offset frequency (-digit). For example, for MHz. The blank digits must be 0. XT S ets or reads the XIT function status. 0: XIT function : XIT function X T X T X T

26

TS-590S TS-590SG. PC CONTROL COMMAND Reference Guide. B5A-0316-20 (July/28/2015)

TS-590S TS-590SG. PC CONTROL COMMAND Reference Guide. B5A-0316-20 (July/28/2015) TS-590S TS-590SG PC CONTROL COMMAND Reference Guide B5A-0316-20 (July/28/2015) PC CONTROL COMMAND REFERENCE GUIDE ABOUT THIS REFERENCE GUIDE All descriptions in this reference guide are for the user s

More information

TS-480HX/TS-480SAT. HF/50MHz All-Mode Transceiver KENWOOD. NETWORK COMMAND SYSTEM with Voice over Internet Protocol capability

TS-480HX/TS-480SAT. HF/50MHz All-Mode Transceiver KENWOOD. NETWORK COMMAND SYSTEM with Voice over Internet Protocol capability TS-480HX/TS-480SAT HF/50MHz All-Mode Transceiver KENWOOD NETWORK COMMAND SYSTEM with Voice over Internet Protocol capability DX Distinction Creative Concept, Elegant Engineering 200W output (50MHz: 100W)

More information

FT-991 YAESU MUSEN CO., LTD.

FT-991 YAESU MUSEN CO., LTD. FT-99 CAT Operation Reference Book YAESU MUSEN CO., LTD. Overview The CAT (Computer Aided Transceiver) System in the FT-99 transceiver provides control of frequency, VFO, memory, and other settings such

More information

Kenwood introduces. new HF/50MHz All-Mode Transceiver

Kenwood introduces. new HF/50MHz All-Mode Transceiver New Product Release Information Oct 2014 TS-590SG HF/ 50MHz All-Mode TRANSCEIVER_ Kenwood introduces Updated to new G version new HF/50MHz All-Mode Transceiver Four years ago we launched our best-selling

More information

MAINTENANCE & ADJUSTMENT

MAINTENANCE & ADJUSTMENT MAINTENANCE & ADJUSTMENT Circuit Theory The concept of PLL system frequency synthesization is not of recent development, however, it has not been a long age since the digital theory has been couplet with

More information

INSTRUCTION MANUAL. Version: 1.05. 144/440 MHz FM DUAL BANDER TH-D72A. 144/430 MHz FM DUAL BANDER TH-D72E

INSTRUCTION MANUAL. Version: 1.05. 144/440 MHz FM DUAL BANDER TH-D72A. 144/430 MHz FM DUAL BANDER TH-D72E INSTRUCTION MANUAL 144/440 MHz FM DUAL BANDER TH-D72A 144/430 MHz FM DUAL BANDER TH-D72E Version: 1.05 CONTENTS Operation File name (TH-D72_) OPERATING THROUGH REPEATERS... REPEATER REPEATER ACCESS...

More information

Youkits TJ2B 2016 SSB CW HF TRANSCEIVER OPERATION GUIDE

Youkits TJ2B 2016 SSB CW HF TRANSCEIVER OPERATION GUIDE Youkits TJ2B 2016 SSB CW HF TRANSCEIVER OPERATION GUIDE TJ2B is a high-performance QRP portable multi-band SSB/CW transceiver, used with DDS as LO, offering wide frequency coverage and fine tuning rate.

More information

RS232C < - > RS485 CONVERTER S MANUAL. Model: LD15U. Phone: 91-79-4002 4896 / 97 / 98 (M) 0-98253-50221 www.interfaceproducts.info

RS232C < - > RS485 CONVERTER S MANUAL. Model: LD15U. Phone: 91-79-4002 4896 / 97 / 98 (M) 0-98253-50221 www.interfaceproducts.info RS232C < - > RS485 CONVERTER S MANUAL Model: LD15U INTRODUCTION Milestone s model LD-15U is a RS232 to RS 485 converter is designed for highspeed data transmission between computer system and or peripherals

More information

TH-F6A TH-F7E INSTRUCTION MANUAL MULTI-BAND PORTABLE TRANSCEIVER DUAL-BAND PORTABLE TRANSCEIVER

TH-F6A TH-F7E INSTRUCTION MANUAL MULTI-BAND PORTABLE TRANSCEIVER DUAL-BAND PORTABLE TRANSCEIVER INSTRUCTION MANUAL MULTI-BAND PORTABLE TRANSCEIVER TH-F6A DUAL-BAND PORTABLE TRANSCEIVER TH-F7E KENWOOD CORPORATION B62-1441-00 (K) 09 08 07 06 05 04 03 02 01 00 MODELS COVERED BY THIS MANUAL The models

More information

Compact Rugged Design. 300 Memory Channels. Single Head Remote Option. 6 Programmable Function Keys. Enhanced Kenwood Audio. 100W Transmit Power*

Compact Rugged Design. 300 Memory Channels. Single Head Remote Option. 6 Programmable Function Keys. Enhanced Kenwood Audio. 100W Transmit Power* HF TRANSCEIVER Compact Rugged Design 300 Memory Channels Single Head Remote Option 6 Programmable Function Keys Enhanced Kenwood Audio 100W Transmit Power* High-stability TCXO Enhanced Security Features

More information

Dealer s Manual VHF FM MOBILE TRANSCEIVER

Dealer s Manual VHF FM MOBILE TRANSCEIVER VHF FM MOBILE TRANSCEIVER Dealer s Manual Alinco s DR-135 transceivers support the Channel Indication mode (User s mode), which protects dealer-defined parameter settings from being changed by the user.

More information

LDG Electronics External Meter Serial Communications Protocol Specification

LDG Electronics External Meter Serial Communications Protocol Specification M1000 METER PROTOCOL SPECIFICATION MANUAL REV A LDG Electronics External Meter Serial Communications Protocol Specification LDG Electronics 1445 Parran Road St. Leonard MD 20685-2903 USA Phone: 410-586-2177

More information

Test Report: Yaesu FTDX-1200, S/N 3F02051 (loaned by Bill Trippett W7VP)

Test Report: Yaesu FTDX-1200, S/N 3F02051 (loaned by Bill Trippett W7VP) Test Report: Yaesu FTDX-1200, S/N 3F02051 (loaned by Bill Trippett W7VP) Adam M. Farson VA7OJ/AB4OJ, 19-21 July 2013 1. Introduction and Scope: The following tests were conducted on the FTDX-1200: A. Receiver

More information

SB-2000 USB Radio Interface Operating Manual CG Antenna Co. Ltd.

SB-2000 USB Radio Interface Operating Manual CG Antenna Co. Ltd. CG Antenna SB-2000 USB Radio Interface Operating Manual CG Antenna Co. Ltd. Shanghai, China FEATURES Connect your computer with USB port. No need serial or parallel port. Most of Radio programs are built

More information

DX 2517. AM FM SSB CW PA Amateur Base Station Transceiver OWNER S MANUAL RX / TX 2 4 POWER NF CHANNEL MODE RF POWER OFF CAL OFF OFF CALIBRATE

DX 2517. AM FM SSB CW PA Amateur Base Station Transceiver OWNER S MANUAL RX / TX 2 4 POWER NF CHANNEL MODE RF POWER OFF CAL OFF OFF CALIBRATE 1 2 3 6 4050 ULA 6070 TI 80 90 100 9 DX 2517 2517 RX / TX 0 2 4 SWR WATTS SET 81012 22 1 010 3 2030 5 MOD 7 ON dbover 9 SIGNAL +20 +40+60 PA FM AM USB LSB CW POWER ON SWR NB / ANL R.BEEP +10KHz NF CHANNEL

More information

TS-2000/2000X. All-Mode Multibander TS-B2000

TS-2000/2000X. All-Mode Multibander TS-B2000 TS-2000/2000X All-Mode Multibander TS-B2000 Distinctive by Design, Packed for Performance All-mode multibander: HF/50/144/440/1200MHz* in one compact rig offering wide-band receive (500kHz to 1300MHz,

More information

PM1122 INT DIGITAL INTERFACE REMOTE

PM1122 INT DIGITAL INTERFACE REMOTE PM1122 INT DIGITAL INTERFACE REMOTE PM1122 INT front panel description: 1. Clear wireless remotes knob: push this button for more than 2 seconds to clear the list of all assigned wireless remote settings

More information

ELAD FDM-SW1 USER MANUAL. Ver. 1.0

ELAD FDM-SW1 USER MANUAL. Ver. 1.0 ELAD FDM-SW1 USER MANUAL Ver. 1.0 Index 1 FDM-SW1 Overview... 4 2 Graphical User Interface (GUI)... 5 2.1 Display Window... 6 2.1.1 Filter Spectrum... 6 2.1.2 Click Options... 7 2.1.3 Graphics Settings...

More information

Alpha 10 SERVICE MANUAL. Downloaded from www.cbradio.nl. MAX 10 Meter Amateur Transceiver AM/FM/CW/SSB 6 BAND PROGRAMMABLE MODEL AM-1000.

Alpha 10 SERVICE MANUAL. Downloaded from www.cbradio.nl. MAX 10 Meter Amateur Transceiver AM/FM/CW/SSB 6 BAND PROGRAMMABLE MODEL AM-1000. Alpha 10 MAX 10 Meter Amateur Transceiver MODEL AM-1000 AM/FM/CW/SSB 6 BAND PROGRAMMABLE SERVICE MANUAL Downloaded from www.cbradio.nl Cover Page LOUDER TALKBACK MOD Alpha 10 Max - Model AM-1000 4.7K Resistor

More information

Smarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier INTRODUCTION

Smarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier INTRODUCTION Smarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier INTRODUCTION The Smarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier is a multi-functional compact device. It

More information

TASCAM SS-CDR200/SS-R200 CONTROL I/O Terminals RS-232C Protocol Specifications

TASCAM SS-CDR200/SS-R200 CONTROL I/O Terminals RS-232C Protocol Specifications TASCAM CONTROL I/O Terminals RS-232C Protocol Specifications TEAC Corporation - 1 - ATTENTION TEAC Corporation ("TEAC") licenses you the protocol specified in this document, assuming that you agree to

More information

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter BIT COMMANDER Serial RS232 / RS485 to Ethernet Converter (Part US2000A) Copyrights U.S. Converters 1 Contents Overview and Features... 3 Functions..5 TCP Server Mode... 5 Httpd Client Mode.5 TCP Auto mode....6

More information

Control projector by using a personal computer

Control projector by using a personal computer LCD Projector X500U / X490U / S490U Control by using a personal computer This can be controlled by connecting a personal computer with RS-232C terminal. Functions can be controlled by a personal computer:

More information

Radio Interface Setup

Radio Interface Setup For getting started with Ham Radio Sound Card digital modes. Jeffrey Kopcak K8JTK Table of Contents Introduction... 3 Program versions... 3 Resources... 3 SignaLink... 3 Rigblaster... 3 Configuration...

More information

VMR6512 Hi-Fi Audio FM Transmitter Module

VMR6512 Hi-Fi Audio FM Transmitter Module General Description VMR6512 is a highly integrated FM audio signal transmitter module. It integrates advanced digital signal processor (DSP), frequency synthesizer RF power amplifier and matching network.

More information

RS-232 Communications Using BobCAD-CAM. RS-232 Introduction

RS-232 Communications Using BobCAD-CAM. RS-232 Introduction RS-232 Introduction Rs-232 is a method used for transferring programs to and from the CNC machine controller using a serial cable. BobCAD-CAM includes software for both sending and receiving and running

More information

RCForb Server Setup. Overview

RCForb Server Setup. Overview RCForb Server Setup Overview The RcForb Server allows you to setup your own remote station on Remote Hams. Three connections to your transceiver are required, and an Internet connection. The first required

More information

CAT (COMPUTER AIDED TRANSCEIVER) OPERATION FT-450 CAT OPERATION FT-450 CAT OPERATION REFERENCE BOOK

CAT (COMPUTER AIDED TRANSCEIVER) OPERATION FT-450 CAT OPERATION FT-450 CAT OPERATION REFERENCE BOOK CAT (CMPUTER AIDED TRANSCEIVER) PERATIN FT-450 CAT PERATIN REFERENCE BK FT-450 CAT PERATIN REFERENCE BK CAT (CMPUTER AIDED TRANSCEIVER) PERATIN VERVIEW The CAT (Computer Aided Transceiver) System in the

More information

DVB-T2 DIGITAL TV BOX

DVB-T2 DIGITAL TV BOX DVB-T2 DIGITAL TV BOX QUALITY OF DIGITAL TELEVISION MT4159 User Manual EN 2 Index Index...2 Introduction...3 Front panel...3 Rear panel...3 Remote control...4 Hardware configuration...5 Connecting tuner

More information

K2 CW Filter Alignment Procedures Using Spectrogram 1 ver. 5 01/17/2002

K2 CW Filter Alignment Procedures Using Spectrogram 1 ver. 5 01/17/2002 K2 CW Filter Alignment Procedures Using Spectrogram 1 ver. 5 01/17/2002 It will be assumed that you have already performed the RX alignment procedures in the K2 manual, that you have already selected the

More information

TS-480HX TS-480SAT CONTENTS. Preface

TS-480HX TS-480SAT CONTENTS. Preface Preface This in-depth manual for the TS-480 was written by the engineers who actually planned and designed the product. It is our hope that this guide will serve to convey the joys of HF and all the benefits

More information

VHF COMMUNICATION TRANSCEIVER

VHF COMMUNICATION TRANSCEIVER ATR-500 VHF COMMUNICATION TRANSCEIVER ON OFF OPERATION MANUAL Manual Number 01.125.010.08 REVISION 1.3, Jan 20. 2005 from S/N 00301 04 Contents 1 SECTION 1 GENERAL INFORMATION...3 1.1 INTRODUCTION...3

More information

User s Manual. version 2.2.1. Edition 20130624-0 2013 - PCR AnyWhere. PCR AnyWhere 2.2.1 User s Manual 1

User s Manual. version 2.2.1. Edition 20130624-0 2013 - PCR AnyWhere. PCR AnyWhere 2.2.1 User s Manual 1 User s Manual version 2.2.1 PCR AnyWhere 2.2.1 User s Manual 1 Edition 20130624-0 2013 - PCR AnyWhere PCR AnyWhere 2.2.1 User s Manual 2 Contents Contents 3 1 About PCR AnyWhere 5 2 Requirements 6 2.1

More information

How To Use A Sound Card With A Subsonic Sound Card

How To Use A Sound Card With A Subsonic Sound Card !"## $#!%!"# &"#' ( "#' )*! #+ #,# "##!$ -+./0 1" 1! 2"# # -&1!"#" (2345-&1 #$6.7 -&89$## ' 6! #* #!"#" +" 1##6$ "#+# #-& :1# # $ #$#;1)+#1#+

More information

DECT Module UM-9802 Datasheet

DECT Module UM-9802 Datasheet UWIN TECHNOLOGIES CO., LTD. DECT Module UM-9802 Datasheet V2.1 1 UWIN TECHNOLOGIES CO., LTD. Contents 1. Introduction... 3 2. Features... 3 3. DECT Module Application... 3 4. DECT Module function block...

More information

F2103 GPRS DTU USER MANUAL

F2103 GPRS DTU USER MANUAL F2103 GPRS DTU USER MANUAL Add:J1-J2,3rd Floor,No.44,GuanRi Road,SoftWare Park,XiaMen,China 1 Zip Code:361008 Contents Chapter 1 Brief Introduction of Product... 3 1.1 General... 3 1.2 Product Features...

More information

NC-12 Modbus Application

NC-12 Modbus Application NC-12 Modbus Application NC-12 1 Table of Contents 1 Table of Contents... 2 2 Glossary... 3 SCADA...3 3 NC-12 Modbus in general... 3 4 Entire system... 4 4.1 PFC to PC connection alternatives...4 4.1.1

More information

Peerless Performance TS-590S. HF / 50 MHz ALL MODE TRANSCEIVER

Peerless Performance TS-590S. HF / 50 MHz ALL MODE TRANSCEIVER Peerless Performance HF / 50 MHz ALL MODE TRANSCEIVER Discovering the Hidden The marks a bold new chapter in Kenwood s proud history of high-performance HF transceivers. Featuring a narrow-band Roofing

More information

Plena Voice Alarm System. Software Manual Configuration Software

Plena Voice Alarm System. Software Manual Configuration Software Plena Voice Alarm System en Software Manual Configuration Software Plena Voice Alarm System Software Manual Table of Contents en 3 Table of Contents Table of Contents...3 1. Introduction...7 1.1 Purpose...7

More information

A CW QRP Transceiver for 20 m band. How it works I'll describe individually the three boards and the relative tuning devices.

A CW QRP Transceiver for 20 m band. How it works I'll describe individually the three boards and the relative tuning devices. A CW QRP Transceiver for 20 m band The little QRP presented in this article may be built in a gradual manner, in fact it is divided in two main modules (plus VFO), you may also complete only a single part

More information

INTRODUCTION TO COMMUNICATION SYSTEMS AND TRANSMISSION MEDIA

INTRODUCTION TO COMMUNICATION SYSTEMS AND TRANSMISSION MEDIA COMM.ENG INTRODUCTION TO COMMUNICATION SYSTEMS AND TRANSMISSION MEDIA 9/6/2014 LECTURES 1 Objectives To give a background on Communication system components and channels (media) A distinction between analogue

More information

Single channel data transceiver module WIZ2-434

Single channel data transceiver module WIZ2-434 Single channel data transceiver module WIZ2-434 Available models: WIZ2-434-RS: data input by RS232 (±12V) logic, 9-15V supply WIZ2-434-RSB: same as above, but in a plastic shell. The WIZ2-434-x modules

More information

RS - SPM. Serial parallel translator module

RS - SPM. Serial parallel translator module ReSatron GmbH Boisheimer Str. 162 D-41751 Viersen Telefon (+49) 02162-45 06 80 Telefax (+49) 02162-45 03 04 email: info@resatron.de RS - SPM Serial parallel translator module RSSPM000215SPM-021 - Subject

More information

ELECRAFT KX3 EXTENDED VFO TEMPERATURE COMPENSATION PROCEDURE Copyright 2012 Elecraft LLC Rev. A8, October 27, 2012

ELECRAFT KX3 EXTENDED VFO TEMPERATURE COMPENSATION PROCEDURE Copyright 2012 Elecraft LLC Rev. A8, October 27, 2012 ELECRAFT KX3 EXTENDED VFO TEMPERATURE COMPENSATION PROCEDURE Copyright 2012 Elecraft LLC Rev. A8, October 27, 2012 Introduction The KX3 standard VFO temperature compensation is entirely adequate for most

More information

SR2000 FREQUENCY MONITOR

SR2000 FREQUENCY MONITOR SR2000 FREQUENCY MONITOR THE FFT SEARCH FUNCTION IN DETAILS FFT Search is a signal search using FFT (Fast Fourier Transform) technology. The FFT search function first appeared with the SR2000 Frequency

More information

Elo Interactive Digital Signage (IDS): Remote Management

Elo Interactive Digital Signage (IDS): Remote Management APPLICATION NOTES Elo Interactive Digital Signage (IDS): Remote Management Large signage installations require a way to manage the devices from a central location. Elo IDS displays are designed with this

More information

Content. Maintenance. Features ENGLISH. 1 transceiver 1 antenna 1 battery pack 1 belt clip 1 fast desktop charger User manual

Content. Maintenance. Features ENGLISH. 1 transceiver 1 antenna 1 battery pack 1 belt clip 1 fast desktop charger User manual Contents Maintenance... 2 Features... 2 Main indicators/controls... 3 LCD display... 5 Basic operations... 6 Advanced operations... 15 Menu operations Self-Programming mode... 17 Self-programming chart...

More information

Product Information S N O. Portable VIP protection CCTV & Alarm System 2

Product Information S N O. Portable VIP protection CCTV & Alarm System 2 Product Information S N O Portable VIP protection CCTV & Alarm System 2 G O V E R N M E N T A L S E C U R I T Y S O L U T I VIP KIT Rapid Deployment VIP Protection Kit The VIP KIT has been designed to

More information

ipcr1000 INSTRUCTION MANUAL COMMUNICATIONS RECEIVER FOR COMPUTER

ipcr1000 INSTRUCTION MANUAL COMMUNICATIONS RECEIVER FOR COMPUTER INSTRUCTION MANUAL COMMUNICATIONS RECEIVER FOR COMPUTER ipcr1000 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause

More information

TS-990SE HF/50MHz All-Mode Transceiver

TS-990SE HF/50MHz All-Mode Transceiver New Product Release Information TS-990SE HF/50MHz All-Mode Transceiver January 2013 We are pleased to inform you of our new HF/ 50MHz all mode Transceiver for Amateur Radio. 1. SCHEDULE Launch: End of

More information

- 35mA Standby, 60-100mA Speaking. - 30 pre-defined phrases with up to 1925 total characters.

- 35mA Standby, 60-100mA Speaking. - 30 pre-defined phrases with up to 1925 total characters. Contents: 1) SPE030 speech synthesizer module 2) Programming adapter kit (pcb, 2 connectors, battery clip) Also required (for programming) : 4.5V battery pack AXE026 PICAXE download cable Specification:

More information

Quick Installation. A Series of Intelligent Bar Code Reader with NeuroFuzzy Decoding. Quick Installation

Quick Installation. A Series of Intelligent Bar Code Reader with NeuroFuzzy Decoding. Quick Installation Quick Installation A Series of Intelligent Bar Code Reader with NeuroFuzzy Decoding This chapter intends to get your new FuzzyScan scanner working with your existing system within minutes. General instructions

More information

LTM-1338B. Plus Communications Manual

LTM-1338B. Plus Communications Manual LTM-1338B Plus Communications Manual 2000. Best Power, Necedah, Wisconsin All rights reserved. Best Power The System Setup option from the Main Menu on the front panel is passwordprotected. The default

More information

Audio processing and ALC in the FT-897D

Audio processing and ALC in the FT-897D Audio processing and ALC in the FT-897D I recently bought an FT-897D, and after a period of operation noticed problems with what I perceived to be a low average level of output power and reports of muffled

More information

TDP-136 TRANSCEIVER DATA PROGRAMMER

TDP-136 TRANSCEIVER DATA PROGRAMMER TDP-136 TRANSCEIVER DATA PROGRAMMER PC SOFTWARE INSTALLATION & OPERATING INSTRUCTIONS Til Document No. 00RE277 Rev. A (Software V1.1x) NOV 2000 Technisonic Industries Limited 250 Watline Avenue, Mississauga,

More information

DAB1001. Wireless Digital Radio Interface. Installation & User Guide

DAB1001. Wireless Digital Radio Interface. Installation & User Guide DAB1001 Wireless Digital Radio Interface Installation & User Guide Contents Contents... 2 Introduction... 3 Contents of Package... 4 Installation... 5 Product Overview... 5 Installation Procedure... 5

More information

How to setup a serial Bluetooth adapter Master Guide

How to setup a serial Bluetooth adapter Master Guide How to setup a serial Bluetooth adapter Master Guide Nordfield.com Our serial Bluetooth adapters part UCBT232B and UCBT232EXA can be setup and paired using a Bluetooth management software called BlueSoleil

More information

1. Make sure that no client accounts are open. 2. Click on Setup, then click Modem. The Modem Setup window will appear.

1. Make sure that no client accounts are open. 2. Click on Setup, then click Modem. The Modem Setup window will appear. SECURITY SYSTEM MANAGEMENT SOFTWARE FOR WINDOWS WINLOAD MODEM SETUP The modem setup is a very important step in the connection process. If the modem setup is not properly completed communication between

More information

CLOUD DCM1. Serial Control Protocol

CLOUD DCM1. Serial Control Protocol DCM-1 Serial Control Protocol Page 1 of 21 CLOUD DCM1 Serial Control Protocol CLOUD ELECTRONICS LIMITED Cloud Electronics Limited 140 Staniforth Road, Sheffield S9 3HF, England Phone +44 (0)114 244 7051.

More information

This guide describes the details that are necessary for making a HMI (PC RT or panel) for an S5 PLC.

This guide describes the details that are necessary for making a HMI (PC RT or panel) for an S5 PLC. Page 1 of 8 HOWTO_setup_and_connect_panel_to_S5.doc date: 20-01-11. - JMP / 6011 This guide describes the details that are necessary for making a HMI (PC RT or panel) for an S5 PLC. A typical application

More information

CENTRONICS interface and Parallel Printer Port LPT

CENTRONICS interface and Parallel Printer Port LPT Course on BASCOM 8051 - (37) Theoretic/Practical course on BASCOM 8051 Programming. Author: DAMINO Salvatore. CENTRONICS interface and Parallel Printer Port LPT The Parallel Port, well known as LPT from

More information

MANUAL PC1000R INFO@APART-AUDIO.COM

MANUAL PC1000R INFO@APART-AUDIO.COM MANUAL PC1000R INFO@APART-AUDIO.COM Features The APart PC1000R is a professional multisource CD/USB/SD card music player, equipped with balanced and unbalanced analog outputs, coaxial and optical digital

More information

Contents. How to Program Radios...3. Keypad Programming...3

Contents. How to Program Radios...3. Keypad Programming...3 Contents How to Program Radios...3 Keypad Programming...3 General Settings (Channel 0)...4 Group Password...5 Automatic Numeric Identifi cation (ANI)...6 Transmitter Time-Out Timer...6 Scan Delay Time...7

More information

DVB-T 730. User s Manual

DVB-T 730. User s Manual EPG Program Reservation There are 10 program timers to bring up reminder for a reserved program. 20 seconds before the start of the reserved program, a pop-up window will remind viewer. If no further instruction,

More information

Controls. LCD Display. Tuning Up Time Set and Station Scan

Controls. LCD Display. Tuning Up Time Set and Station Scan PR-D8 GB Revision 3 1 1 2 4 5 7 9 10 12 14 16 18 20 22 24 25 26 27 29 31 33 35 36 37 38 Controls Stereo Built-in Microphone (Left Channel) LCD Display Stereo Built-in Microphone (Right channel) Power/Auto

More information

Controlling the projector using a personal computer

Controlling the projector using a personal computer AUDIO OUT AUDIO IN-1 AUDIO IN-2 AUDIO IN-3L AUDIO IN-3R S-VIDEO VIDEO SERIAL MONITOR OUT COMPUTER / COMPONENT VIDEO IN-1 IN-2 USB-B USB-A TM DLP Projector MODEL XD550U/XD560U/WD570U/XD360U-EST/WD380U-EST

More information

IC-756 Pro III vs. Pro II

IC-756 Pro III vs. Pro II IC-756 Pro III vs. Pro II Improvements in the Pro III vs. the Pro II Adam Farson VA7OJ IC-756Pro3 Information & Links Copyright 2006 North Shore Amateur Radio Club NSARC HF Operators 756Pro3 vs. Pro2 1

More information

ZLPLL Local Oscillator

ZLPLL Local Oscillator ZLPLL Local Oscillator Wayne Knowles, ZL2BKC w.knowles@xtra.co.nz Contents 1 Introduction... 3 2 Specifications... 3 3 Performance... 4 3.1 Phase Noise... 4 3.2 Output Level... 4 3.3 Harmonic Level...

More information

PCMCIA 1 Port RS232 2.1 EDITION OCTOBER 1999

PCMCIA 1 Port RS232 2.1 EDITION OCTOBER 1999 232 232232 PCMCIA 1 Port RS232 2.1 EDITION OCTOBER 1999 Guarantee. FULL 36 MONTHS GUARANTEE. We guarantee your interface card for a full 36 months from purchase, parts and labour, provided it has been

More information

Digital Communications How to Get Started Guide

Digital Communications How to Get Started Guide Digital Communications How to get started guide Table of Contents Introduction page 2 Modes page 2 Software page 2 Hardware page 3 Setup page 4 Tuning page 6 Operating page 7 Digital Nets page 7 Operating

More information

January 2009. i7600. HF/50MHz TRANSCEIVER

January 2009. i7600. HF/50MHz TRANSCEIVER January 2009 HF/50MHz TRANSCEIVER i7600 Icom proudly announces debut of the HF/50MHz transceiver IC-7600. Since the first release in 1996, four generations of the IC-756 series have earned a formidable

More information

Using a Laptop Computer with a USB or Serial Port Adapter to Communicate With the Eagle System

Using a Laptop Computer with a USB or Serial Port Adapter to Communicate With the Eagle System Using a Laptop Computer with a USB or Serial Port Adapter to Communicate With the Eagle System ECU DB9 USB 20-060_A.DOC Page 1 of 18 9/15/2009 2009 Precision Airmotive LLC This publication may not be copied

More information

DRM compatible RF Tuner Unit DRT1

DRM compatible RF Tuner Unit DRT1 FEATURES DRM compatible RF Tuner Unit DRT1 High- Performance RF Tuner Frequency Range: 10 KHz to 30 MHz Input ICP3: +13,5dBm, typ. Noise Figure @ full gain: 14dB, typ. Receiver Factor: -0,5dB, typ. Input

More information

A RF18 Remote control receiver MODULE

A RF18 Remote control receiver MODULE A RF18 Remote control receiver MODULE User Guide No part of this document may be reproduced or transmitted (in electronic or paper version, photocopy) without Adeunis RF consent. This document is subject

More information

Objectives. Basics of Serial Communication. Simplex vs Duplex. CMPE328 Microprocessors (Spring 2007-08) Serial Interfacing. By Dr.

Objectives. Basics of Serial Communication. Simplex vs Duplex. CMPE328 Microprocessors (Spring 2007-08) Serial Interfacing. By Dr. CMPE328 Microprocessors (Spring 27-8) Serial Interfacing By Dr. Mehmet Bodur Objectives Upon completion of this chapter, you will be able to: List the advantages of serial communication over parallel communication

More information

CONCEPT1 RS232 COMMUNICATION

CONCEPT1 RS232 COMMUNICATION Concept 1 RS-232 Communication Communication with Concept 1 via RS-232 is done with simple ASCII Commands and Replies. The port settings are 19200Baud, 8bits, no parity and 1 stop bit. The physical connection

More information

SR450 RECEIVER OPERATING INSTRUCTIONS 1892 1128

SR450 RECEIVER OPERATING INSTRUCTIONS 1892 1128 SR450 RECEIVER OPERATING INSTRUCTIONS 1892 1128 These operating instructions are intended to provide the user with sufficient information to install and operate the module correctly. The Wood & Douglas

More information

PRT3 Printer Module: ASCII Protocol Programming Instructions

PRT3 Printer Module: ASCII Protocol Programming Instructions PRT3 Printer Module: ASCII Protocol Programming Instructions We hope this product performs to your complete satisfaction. Should you have any questions or comments, please visit www.paradox.com and send

More information

1. SAFETY INFORMATION

1. SAFETY INFORMATION RS-232 Sound Level Meter 72-860A INSTRUCTION MANUAL www.tenma.com 1. SAFETY INFORMATION Read the following safety information carefully before attempting to operate or service the meter. Use the meter

More information

MANUAL FOR RX700 LR and NR

MANUAL FOR RX700 LR and NR MANUAL FOR RX700 LR and NR 2013, November 11 Revision/ updates Date, updates, and person Revision 1.2 03-12-2013, By Patrick M Affected pages, ETC ALL Content Revision/ updates... 1 Preface... 2 Technical

More information

OPTIMA MK2 OWNERS MANUAL & USER GUIDE. Downloaded from www.cbradio.nl. 24.500 29.999 Mhz 50W All Mode HF Mobile Transceiver

OPTIMA MK2 OWNERS MANUAL & USER GUIDE. Downloaded from www.cbradio.nl. 24.500 29.999 Mhz 50W All Mode HF Mobile Transceiver OPTIMA MK2 OWNERS MANUAL & USER GUIDE Downloaded from www.cbradio.nl 24.500 29.999 Mhz 50W All Mode HF Mobile Transceiver (February 2012 production) REV 1.61 Copyright January 2012 by YeticomNZ. All rights

More information

USART and Asynchronous Communication

USART and Asynchronous Communication The USART is used for synchronous and asynchronous serial communication. USART = Universal Synchronous/Asynchronous Receiver Transmitter Our focus will be on asynchronous serial communication. Asynchronous

More information

There are three different ways to program Bendix/King radios:

There are three different ways to program Bendix/King radios: HOW TO PROGRAM RADIOS There are three different ways to program Bendix/King radios: * By Keyboard A radio with a keyboard and LCD display can be programmed by using its keyboard and a programming plug

More information

Modbus Communications for PanelView Terminals

Modbus Communications for PanelView Terminals User Guide Modbus Communications for PanelView Terminals Introduction This document describes how to connect and configure communications for the Modbus versions of the PanelView terminals. This document

More information

AR5001D. Digital Processing Communications Receiver. Operating manual AOR, LTD.

AR5001D. Digital Processing Communications Receiver. Operating manual AOR, LTD. AR5001D Digital Processing Communications Receiver Operating manual AOR, LTD. Table of Contents 0 1 INTRODUCTION... 5 1-1 INTRODUCTION... 5 1-2 TAKE CARE OF YOUR RECEIVER... 7 1-3 INCLUDED IN THIS PACKAGE...

More information

Software User Guide. ExpertSDR2

Software User Guide. ExpertSDR2 Software User Guide ExpertSDR2 Introduction The program, ExpertSDR2, is designed to support SDR hardware modules designed and built by the Expert Electronics Company. The program controls the SunSDR and

More information

Rev 06 1211. GSM base station. Installation instructions

Rev 06 1211. GSM base station. Installation instructions Rev 06 1211 GSM base station Installation instructions Output string format Baud rate 115200 bps Parity none Data bits 8 Stop bits 1 Flow control none The output string is a modified version of the Sureguard

More information

Elettronica dei Sistemi Digitali Costantino Giaconia SERIAL I/O COMMON PROTOCOLS

Elettronica dei Sistemi Digitali Costantino Giaconia SERIAL I/O COMMON PROTOCOLS SERIAL I/O COMMON PROTOCOLS RS-232 Fundamentals What is RS-232 RS-232 is a popular communications interface for connecting modems and data acquisition devices (i.e. GPS receivers, electronic balances,

More information

FTB8800 Software. Programming the FT 8800R with FTB8800. A Companion to Yaesu FT 8800R Operating Manual: The W5JCK Expanded Version

FTB8800 Software. Programming the FT 8800R with FTB8800. A Companion to Yaesu FT 8800R Operating Manual: The W5JCK Expanded Version FTB8800 Software Programming the FT 8800R with FTB8800 A Companion to Yaesu FT 8800R Operating Manual: The W5JCK Expanded Version This manual is courtesy of W5JCK November 2006 Copyright 2006 by Ceburn

More information

Software Manual RS232 Laser Merge Module. Document # SU-256521-09 Rev A

Software Manual RS232 Laser Merge Module. Document # SU-256521-09 Rev A Laser Merge Module Document # SU-256521-09 Rev A The information presented in this document is proprietary to Spectral Applied Research Inc. and cannot be used for any purpose other than that for which

More information

CAT (COMPUTER AIDED TRANSCEIVER) OPERATION FT-950 CAT OPERATION FT-950 CAT OPERATION REFERENCE BOOK

CAT (COMPUTER AIDED TRANSCEIVER) OPERATION FT-950 CAT OPERATION FT-950 CAT OPERATION REFERENCE BOOK CAT (CMPUTER AIDED TRANSCEIVER) PERATIN FT-950 CAT PERATIN REFERENCE BK FT-950 CAT PERATIN REFERENCE BK CAT (CMPUTER AIDED TRANSCEIVER) PERATIN VERVIEW The CAT (Computer Aided Transceiver) System in the

More information

T3 Mux M13 Multiplexer

T3 Mux M13 Multiplexer T3 Mux M13 Multiplexer User Manual [Type the abstract of the document here. The abstract is typically a short summary of the contents of the document. Type the abstract of the document here. The abstract

More information

a8251 Features General Description Programmable Communications Interface

a8251 Features General Description Programmable Communications Interface a8251 Programmable Communications Interface June 1997, ver. 2 Data Sheet Features a8251 MegaCore function that provides an interface between a microprocessor and a serial communication channel Optimized

More information

LINDY ELECTRONICS LIMITED & LINDY-ELEKTRONIK GMBH - SECOND EDITION

LINDY ELECTRONICS LIMITED & LINDY-ELEKTRONIK GMBH - SECOND EDITION RS-422/485 PCI Card User Manual English No. 51200 (2 Port) No. 51202 (4 Port) No. 51204 (8 Port) www.lindy.com LINDY ELECTRONICS LIMITED & LINDY-ELEKTRONIK GMBH - SECOND EDITION (Nov 2005) 1.0 Introduction

More information

Interfacing the Yaesu DR 1X

Interfacing the Yaesu DR 1X Interfacing the Yaesu DR 1X With The S Com 7330 Repeater Controller For a Feature Rich Digital and Analog Experience! A Technical Writing by Justin Reed, NV8Q Version 2 Updated May 26, 2015 Introduction

More information

Repeater Mil-Std-1553B Datasheet

Repeater Mil-Std-1553B Datasheet Repeater Mil-Std-1553B Datasheet 1 Summary 1. Environment specification...3 2. Electronic diagram...5 3. Output...6 4. Electrical specifications...7 3. Test...8 3.1. Bus Monitor...8 3.2 Bus Controller...11

More information

The FT-1000MP, MK V and Field: Filter Selection and Modification Guide

The FT-1000MP, MK V and Field: Filter Selection and Modification Guide The FT-1000MP, MK V and Field: Filter Selection and Modification Guide www.inrad.net Copyright International Radio Corporation, Revised Jan 30, 2008 1 The FT-1000MP receiver is triple conversion, with

More information

RS-232 COMMUNICATIONS

RS-232 COMMUNICATIONS Technical Note D64 0815 RS-232 COMMUNICATIONS RS-232 is an Electronics Industries Association (EIA) standard designed to aid in connecting equipment together for serial communications. The standard specifies

More information

INSTRUCTION MANUAL COMMUNICATIONS RECEIVER. ir1500

INSTRUCTION MANUAL COMMUNICATIONS RECEIVER. ir1500 INSTRUCTION MANUAL COMMUNICATIONS RECEIVER ir1500 i FOREWORD Thank you for purchasing this Icom product. The IC-R1500 COMMUNICATIONS RECEIVER is designed and built with Icom s state of the art technology

More information

Timeout The Crosspoint Status Request message has a timeout, which means that you need to wait 1 second in between request messages.

Timeout The Crosspoint Status Request message has a timeout, which means that you need to wait 1 second in between request messages. Network Control Protocol Important notes Binary Code The strings shown on the next pages are in binary coded format. Please be aware that any terminal program you may use to control a Network unit from

More information