Timeout The Crosspoint Status Request message has a timeout, which means that you need to wait 1 second in between request messages.

Size: px
Start display at page:

Download "Timeout The Crosspoint Status Request message has a timeout, which means that you need to wait 1 second in between request messages."

Transcription

1 Network Control Protocol Important notes Binary Code The strings shown on the next pages are in binary coded format. Please be aware that any terminal program you may use to control a Network unit from a PC must be able to generate hexadecimal characters. ASCII characters will not be accepted. Acknowledge / Echo A matrix will reply on a crosspoint set command with an ECHO. In the case where a crosspoint is already set, no ECHO will be sent. If the matrix is part of a Network Control Bus system two types of reply will be sent. Immediately after receiving the crosspoint set command the ECHO will be sent. The matrix will then wait for the command to pass the Network Control Bus system. After receiving the command from the Network Control Bus system the matrix will send the command as an ACKNOWLEDGE. Network Control Protocol Important notes Binary Code The strings shown on the next pages are in binary coded format. Please be aware that any terminal program you may use to control a Network unit from a PC must be able to generate hexadecimal characters. ASCII characters will not be accepted. Acknowledge / Echo A matrix will reply on a crosspoint set command with an ECHO. In the case where a crosspoint is already set, no ECHO will be sent. If the matrix is part of a Network Control Bus system two types of reply will be sent. Immediately after receiving the crosspoint set command the ECHO will be sent. The matrix will then wait for the command to pass the Network Control Bus system. After receiving the command from the Network Control Bus system the matrix will send the command as an ACKNOWLEDGE. Timeout The Crosspoint Status Request message has a timeout, which means that you need to wait 1 second in between request messages. Audio crosspoint set Only for use with Audio Routers. Command for setting of crosspoints: 1001nnnn 0kkk kkkk 0vvv vvvv nnnn is the matrix address from 0 up to 15. kkk kkkk is the output which shall be controlled. o kkk kkkk = output number o 0 = output 1 o 127 = output 128 vvv vvvv is the input which shall be connected to the chosen output. o vvv vvvv = input number Crosspoint status request This command is used for status request on Audio and Video Routers. 1100nnnn 0xxxxxxx nnnn is the matrix address from 0 up to 15. xxxxxxx - do not carry any information The requested Router (Audio or Video) will send its crosspoint status on MIDI OUT and RS232. The same

2 command format as for crosspoint set is used. Video crosspoint set Only for use with Video Routers. Command for setting of crosspoints: 1010nnnn 0kkkkkkk 0vvvvvvv nnnn is the matrix address from 0 up to 15. kkk kkkk is the output which shall be controlled. o kkk kkkk = output number o 0 = output 1 o 127 = output 128 vvv vvvv is the input which shall be connected to the chosen output. vvv vvvv = input number Interface protocol RS232 The RS-232 port is used for external control of VikinX units. The RS-232 port allows the customer to control the equipment via Network s PC Software THOR or self-defined customised solutions. Connector for the RS-232 port is a DS9 female. Pin 2 - Tx. Pin 3 - Rx Pin 5 - GND A standard DCE (Data Communication Equipment) cable can be used for connection between PC and Network equipment. The connection between the connectors is made one-to-one. Data-rate is baud. 8 data-bit, 1 stop-bit, no parity.

3 Appendix N Jupiter ASCII Communications Protocol Revision E 1/11/2000 Hardware connections for an external computer are shown on page Set up in the Jupiter Control System File Server includes defining one or more port pairs as being ASCII in the Serial Protocol Table (page 5 26). The control computer is identified on the MPK Devices table (page 5 130). You will need to define each port as being type Serial, and give each port a CP Level, Input, and Output Set. These sets will determine which levels, inputs, and outputs are available to each ASCII port to control and status. The ASCII Computer Interface is assigned to a SC 3000, SI 3000, or VM 3000 serial port pair and uses a simple ASCII data format defined below. The serial protocol defaults to 9600 Baud, 8 Data Bits, No Parity, and 1 Stop Bit. Baud rates of 2400, 4800, 19.2K and 38.4K are also user configurable from the Jupiter Control System File Server. The control port uses XON (0x11) and XOFF (0x13) to control command pacing if necessary. All commands are in upper case ASCII. Space (0x20) characters are optional and will be ignored. Each command is followed by a carriage return (0x0D). If a line feed (0x0A) is included it must follow the carriage return. The controlling computer must take care to wait for a ZY or ZN response after each command before attempting to send a subsequent command. Failure to do so will result in a ZN response, and possibly an XOFF condition. If switcher status is received, wait for all levels to be statused before sending another command. Here is a key to help you understand the following command descriptions: OOO > Router Switcher OUTPUT. This corresponds with the Selection number defined in this AS- CII port s CP Output Set. The range is from 000 to 999. (Previous releases had a range from 000 to 249.) III > Router Switcher INPUT. This corresponds with the Selection number defined in this ASCII port s CP Input Set. (Previous releases had a range from 000 to 249.) N 1

4 ASCII Protocol LLLLLLL > Router Switcher LEVELS. This corresponds with a logical position in this ASCII port s CP Level Set. The range is from 1 to 7. For example, 1 refers to the first entry in the CP Level Set, and 5 refers to the fifth entry in that same set. If no levels are specified, then the take is assumed to apply to all levels defined in that set. Level number entries are NOT position dependent. ASCII General Purpose Commands ZA Acknowledge This command is used to see if the ASCII interface exists and is running. A response of ZA is returned whenever a ZA is received. ZZ Reset This command forces the ASCII controller to reset. This causes the interface to cancel all previous ZP, ZV, and ZW commands. A ZX response is returned to the external computer upon command completion. This ZX is also returned whenever the interface is manually reset. ZY Command Accepted This response is returned after the serial port has (ACK) successfully parsed the command and in the case of a switch command has successfully issued the TAKE to the system and received a switch response back from the system. This does NOT mean that the command was successfully executed. The remote computer should not issue a new command until receiving a ZY or ZN from the current command. The amount of time for the response will vary depending on system complexity and current system activity. Also the number of switches involved in the command will affect the amount of time it takes to receive the ZY response. Multiple switches sent in one command may result in ZR response(s) being returned before the ZY response. ZN Command Rejected A ZN will be issued when a condition occurs where (NAK) the current command cannot be executed. A ZN response can be issued for several reasons such as an invalid com- N 2

5 ASCII Protocol mand, an invalid command format, or an invalid input, output or level. Invalid inputs, outputs and levels are logged to the system logger. Also if the system is busy a ZN will be issued followed by XOFF. When it is again ready for the next command a XON will be issued. Note that after the XON, response(s) from the prior command may be issued (e.g. ZR response(s)). Router Switcher Control and Status Commands ZSOOOIIILLLLLLL Switch Request This command causes the interface to issue a TAKE Switch Request to the routing switcher control system and affects a single routing switcher output. If no levels are specified, then ALL defined levels are assumed. Note: Passwords are not honored by automation protocol handling. A remote computer can send a command with multiple Switch Requests (older releases do not have this capability). A single command can be up to 180 characters long which allows switching of from outputs (depending on the specified levels). An example of a multiple Switch Request follows: ZS ZS ZS <CR> This example command would switch outputs 0, 1, and 2 on levels 1 and 2. ZROOO Status Request This command requests current switcher status for a single output. The response is in the format: ZROOOIIILLLLLLL. If the status for the output is split, multiple responses will be returned. ZWOOO Watch Output This command causes the interface to watch the specified output for any changes and report such changes. A request to watch output 999 is a request to watch all defined N 3

6 ASCII Protocol outputs in that port s serial output set. All responses are in the ZR format described above. When issued, this command also may result in an immediate ZR response for the requested output(s). No ZR response(s) will be returned if the requested output(s) do not have any inputs assigned to them. ZPOOO Lock Output This command LOCKS the specified output from being changed by any system control device. ZVOOO Protect Output This command PROTECTS the specified output from being changed by any other system control device. ZUOOO Unlock Output This command removes the LOCK or PROTECT from the specified system output. If another system control device or interface locked or protected this output, this command will fail. ZJOOO Report Lock Status This command will return a code based on which kind of system control device or interface LOCKED or PRO- TECTED the specified output. If the output is not locked or protected, no response will be sent. The response codes are as follows: ZJ000 ZJ ZJ999 Jupiter Control Panel Party Line Control Panel THIS ASCII INTERFACE Note: Lock status returned for the first level only in the CP Level Set for this ASCII port. N 4

CONCEPT1 RS232 COMMUNICATION

CONCEPT1 RS232 COMMUNICATION Concept 1 RS-232 Communication Communication with Concept 1 via RS-232 is done with simple ASCII Commands and Replies. The port settings are 19200Baud, 8bits, no parity and 1 stop bit. The physical connection

More information

Router Connection Details

Router Connection Details Router Connection Details Television Systems Limited. Vanwall Road, Maidenhead, Berkshire, SL6 4UB Telephone +44 (0)1628 676200, FAX +44 (0)1628 676299 1 Routers Contents 1 GVG Encore / Prelude / Jupiter

More information

PM1122 INT DIGITAL INTERFACE REMOTE

PM1122 INT DIGITAL INTERFACE REMOTE PM1122 INT DIGITAL INTERFACE REMOTE PM1122 INT front panel description: 1. Clear wireless remotes knob: push this button for more than 2 seconds to clear the list of all assigned wireless remote settings

More information

Using HyperTerminal with Agilent General Purpose Instruments

Using HyperTerminal with Agilent General Purpose Instruments Using HyperTerminal with Agilent General Purpose Instruments Windows HyperTerminal can be used to program most General Purpose Instruments (not the 531xx series counters) using the RS-232 Serial Bus. Instrument

More information

SUDT AccessPort TM Advanced Terminal / Monitor / Debugger Version 1.37 User Manual

SUDT AccessPort TM Advanced Terminal / Monitor / Debugger Version 1.37 User Manual SUDT AccessPort TM Advanced Terminal / Monitor / Debugger Version 1.37 User Manual Version 1.0 - January 20, 2015 CHANGE HISTORY Version Date Description of Changes 1.0 January 20, 2015 Initial Publication

More information

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter BIT COMMANDER Serial RS232 / RS485 to Ethernet Converter (Part US2000A) Copyrights U.S. Converters 1 Contents Overview and Features... 3 Functions..5 TCP Server Mode... 5 Httpd Client Mode.5 TCP Auto mode....6

More information

Application Bulletin

Application Bulletin INTELLIGENT CONTROLS INC PO BOX 638 34 SPRING HILL RD SACO, ME 04072 U S A Application Bulletin 000-2045 REV. B Retrieving Tap Change Indication Data from an INCON1250B via an SEL 2020 or 2030 Communications

More information

LTM-1338B. Plus Communications Manual

LTM-1338B. Plus Communications Manual LTM-1338B Plus Communications Manual 2000. Best Power, Necedah, Wisconsin All rights reserved. Best Power The System Setup option from the Main Menu on the front panel is passwordprotected. The default

More information

MCB3101 (Class I) WiRobot Serial Bluetooth Wireless Module User Manual

MCB3101 (Class I) WiRobot Serial Bluetooth Wireless Module User Manual MCB3101 (Class I) WiRobot Serial Bluetooth Wireless Module User Manual Version: 1.0.1 Dec. 2005 Table of Contents I. Introduction 2 II. Operations 2 II.1. Theory of Operation 2 II.2. Configuration (PC-PC

More information

LS-101 LAN to Serial Device server. User s Manual

LS-101 LAN to Serial Device server. User s Manual LS-101 LAN to Serial Device server User s Manual Revision History Revision No Date Author Remarks 0.1 August 29, 2001 IDC Initial document INTRODUCTION Overview Almost all instruments and most industrial

More information

To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification:

To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification: PURPOSE Verify that communication is established for the following products programming option (488.2 compliant, SCPI only): DCS - M9C & DCS M130, DLM M9E & DLM-M9G & DLM M130, DHP - M9D, P series, SG,

More information

PRT3 Printer Module: ASCII Protocol Programming Instructions

PRT3 Printer Module: ASCII Protocol Programming Instructions PRT3 Printer Module: ASCII Protocol Programming Instructions We hope this product performs to your complete satisfaction. Should you have any questions or comments, please visit www.paradox.com and send

More information

Virtual Integrated Design Getting started with RS232 Hex Com Tool v6.0

Virtual Integrated Design Getting started with RS232 Hex Com Tool v6.0 Virtual Integrated Design Getting started with RS232 Hex Com Tool v6.0 Copyright, 1999-2007 Virtual Integrated Design, All rights reserved. 1 Contents: 1. The Main Window. 2. The Port Setup Window. 3.

More information

When we look at the connector pinout of the RS232 port, we see two pins which are certainly used

When we look at the connector pinout of the RS232 port, we see two pins which are certainly used 1 Null modem - an introduction Serial communications with RS232 1. One of the oldest and most widely spread communication methods in computer world. The way this type of communication can be performed

More information

Modbus Communications for PanelView Terminals

Modbus Communications for PanelView Terminals User Guide Modbus Communications for PanelView Terminals Introduction This document describes how to connect and configure communications for the Modbus versions of the PanelView terminals. This document

More information

isco Connecting Routers Back to Back Through the AUX P

isco Connecting Routers Back to Back Through the AUX P isco Connecting Routers Back to Back Through the AUX P Table of Contents Connecting Routers Back to Back Through the AUX Ports...1 Introduction...1 Before You Begin...1 Conventions...1 Prerequisites...1

More information

CENTRONICS interface and Parallel Printer Port LPT

CENTRONICS interface and Parallel Printer Port LPT Course on BASCOM 8051 - (37) Theoretic/Practical course on BASCOM 8051 Programming. Author: DAMINO Salvatore. CENTRONICS interface and Parallel Printer Port LPT The Parallel Port, well known as LPT from

More information

Single channel data transceiver module WIZ2-434

Single channel data transceiver module WIZ2-434 Single channel data transceiver module WIZ2-434 Available models: WIZ2-434-RS: data input by RS232 (±12V) logic, 9-15V supply WIZ2-434-RSB: same as above, but in a plastic shell. The WIZ2-434-x modules

More information

ESPA 4.4.4 Nov 1984 PROPOSAL FOR SERIAL DATA INTERFACE FOR PAGING EQUIPMENT CONTENTS 1. INTRODUCTION 2. CHARACTER DESCRIPTION

ESPA 4.4.4 Nov 1984 PROPOSAL FOR SERIAL DATA INTERFACE FOR PAGING EQUIPMENT CONTENTS 1. INTRODUCTION 2. CHARACTER DESCRIPTION PROPOSAL FOR SERIAL DATA INTERFACE FOR PAGING EQUIPMENT CONTENTS 1. INTRODUCTION 2. CHARACTER DESCRIPTION 2.1 CHARACTER STRUCTURE 2.2 THE CHARACTER SET 2.3 CONTROL CHARACTERS 2.3.1 Transmission control

More information

SYMETRIX SOLUTIONS: TECH TIP August 2015

SYMETRIX SOLUTIONS: TECH TIP August 2015 String Output Modules The purpose of this document is to provide an understanding of operation and configuration of the two different String Output modules available within SymNet Composer. The two different

More information

RS232C < - > RS485 CONVERTER S MANUAL. Model: LD15U. Phone: 91-79-4002 4896 / 97 / 98 (M) 0-98253-50221 www.interfaceproducts.info

RS232C < - > RS485 CONVERTER S MANUAL. Model: LD15U. Phone: 91-79-4002 4896 / 97 / 98 (M) 0-98253-50221 www.interfaceproducts.info RS232C < - > RS485 CONVERTER S MANUAL Model: LD15U INTRODUCTION Milestone s model LD-15U is a RS232 to RS 485 converter is designed for highspeed data transmission between computer system and or peripherals

More information

TAP Interface Specifications

TAP Interface Specifications TAP Interface Specifications This Document is for those who want to develop their own paging control software or add an interface for the WaveWare v9 Series Paging Encoder to their existing software applications.

More information

How to setup a serial Bluetooth adapter Master Guide

How to setup a serial Bluetooth adapter Master Guide How to setup a serial Bluetooth adapter Master Guide Nordfield.com Our serial Bluetooth adapters part UCBT232B and UCBT232EXA can be setup and paired using a Bluetooth management software called BlueSoleil

More information

Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000

Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000 Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000 1.0 Introduction A Technical Application Note from Doppler System July 5, 1999 Version 3.x of the DDF6000, running version

More information

Introduction: Implementation of the MVI56-MCM module for modbus communications:

Introduction: Implementation of the MVI56-MCM module for modbus communications: Introduction: Implementation of the MVI56-MCM module for modbus communications: Initial configuration of the module should be done using the sample ladder file for the mvi56mcm module. This can be obtained

More information

Software Manual RS232 Laser Merge Module. Document # SU-256521-09 Rev A

Software Manual RS232 Laser Merge Module. Document # SU-256521-09 Rev A Laser Merge Module Document # SU-256521-09 Rev A The information presented in this document is proprietary to Spectral Applied Research Inc. and cannot be used for any purpose other than that for which

More information

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL w w w. c d v g r o u p. c o m CA-ETHR-A: TCP/IP Module Installation Manual Page Table of Contents Introduction...5 Hardware Components... 6 Technical Specifications...

More information

Knowledge Base Article. Integrating ISONAS Access Control System with TagMaster LR-series RFID Readers

Knowledge Base Article. Integrating ISONAS Access Control System with TagMaster LR-series RFID Readers Knowledge Base Article Integrating ISONAS Access Control System with TagMaster LR-series RFID Readers Copyright 2009-2012, ISONAS Security Systems All rights reserved Table of Contents 1: INTRODUCTION...

More information

INTRODUCTION FEATURES OF THE ICM

INTRODUCTION FEATURES OF THE ICM INTRODUCTION The ICM, Internet Control Module, is a remote controller device accessible via the Internet that allows operational access to the IPS (and other base units available). Through the ICM you

More information

SenseLink TM. End-Point Controller. Addendum

SenseLink TM. End-Point Controller. Addendum SenseLink TM End-Point Controller Addendum MKS Instruments, Inc. Control & Information Technology Products Group 3350 Scott Blvd Bldg 4 Santa Clara, CA 95054 Main: 408.235.7620 Fax: 408.235.7625 SenseLink

More information

Table 1 below is a complete list of MPTH commands with descriptions. Table 1 : MPTH Commands. Command Name Code Setting Value Description

Table 1 below is a complete list of MPTH commands with descriptions. Table 1 : MPTH Commands. Command Name Code Setting Value Description MPTH: Commands Table 1 below is a complete list of MPTH commands with descriptions. Note: Commands are three bytes long, Command Start Byte (default is 128), Command Code, Setting value. Table 1 : MPTH

More information

ASCII CONTROL COMMANDS FOR MATRIX SWITCHING SYSTEMS AN_0001

ASCII CONTROL COMMANDS FOR MATRIX SWITCHING SYSTEMS AN_0001 APPLICATION NOTE ASCII CONTROL COMMANDS FOR MATRIX SWITCHING SYSTEMS AN_0001 TABLE OF CONTENTS Section GENERAL DESCRIPTION 1.0 CAMERA TO MONITOR CALL-UP 2.0 TOUR/SEQUENCE CONTROL 3.0 PAN/TILT/LENS CONTROL

More information

Smarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier INTRODUCTION

Smarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier INTRODUCTION Smarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier INTRODUCTION The Smarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier is a multi-functional compact device. It

More information

ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.

ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems. IntesisBox ModBus Server - KNX Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems. Integrate KNX based lighting control into your SCADA, BMS, PLC "talking" Modbus. Master

More information

Controlling the projector using a personal computer

Controlling the projector using a personal computer AUDIO OUT AUDIO IN-1 AUDIO IN-2 AUDIO IN-3L AUDIO IN-3R S-VIDEO VIDEO SERIAL MONITOR OUT COMPUTER / COMPONENT VIDEO IN-1 IN-2 USB-B USB-A TM DLP Projector MODEL XD550U/XD560U/WD570U/XD360U-EST/WD380U-EST

More information

Internet-bridge XPort

Internet-bridge XPort Ing. Z.Královský Ing. Petr Štol Perk 457 Okrajová 1356 675 22 STA 674 01 T EBÍ Development & production of control equipment Tel.: 568 870982 Tel.: 568 848179 Visualization, measurement and regulation

More information

USER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: 2900-300321 Rev 6

USER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: 2900-300321 Rev 6 KRAMER ELECTRONICS LTD. USER GUIDE Ethernet Configuration Guide (Lantronix) P/N: 2900-300321 Rev 6 Contents 1 Connecting to the Kramer Device via the Ethernet Port 1 1.1 Connecting the Ethernet Port Directly

More information

FINS Gateway For OMRON PLCs

FINS Gateway For OMRON PLCs 1 Purpose This Technical Note describes how to set up a remote collaboration. A remote collaboration consists in configuring, programming or monitoring a PLC from a remote location, without the need of

More information

The Answer to the 14 Most Frequently Asked Modbus Questions

The Answer to the 14 Most Frequently Asked Modbus Questions Modbus Frequently Asked Questions WP-34-REV0-0609-1/7 The Answer to the 14 Most Frequently Asked Modbus Questions Exactly what is Modbus? Modbus is an open serial communications protocol widely used in

More information

User Manual. AS-Interface Programmer

User Manual. AS-Interface Programmer AS-Interface Programmer Notice: RESTRICTIONS THE ZMD AS-INTERFACE PROGRAMMER HARDWARE AND ZMD AS-INTERFACE PROGRAMMER SOFTWARE IS DESIGNED FOR IC EVALUATION, LABORATORY SETUP AND MODULE DEVELOPMENT ONLY.

More information

Bluetooth HC-06 with serial port module Easy guide

Bluetooth HC-06 with serial port module Easy guide 1 Bluetooth HC-06 with serial port module Easy guide This manual consists of 3 parts: PART 1. Overview of Bluetooth HC-06 module with serial port. PART 2. Installing Bluetooth HC-06 module with Bolt 18F2550

More information

Using Bluetooth-Enabled PosiTector 6000 with Statistical Process Control Software

Using Bluetooth-Enabled PosiTector 6000 with Statistical Process Control Software Using Bluetooth-Enabled PosiTector 6000 with Statistical Process Control Software SPC programs are available from third party vendors that enhance the measurement capabilities of the PosiTector 6000. With

More information

1.1 Connection. 1.1.1 Direct COM port connection. 1. Half duplex RS232 spy cable without handshaking

1.1 Connection. 1.1.1 Direct COM port connection. 1. Half duplex RS232 spy cable without handshaking POS function Marchen POS-DVR surveillance system is a professional surveillance integrated with POS system. By bringing video and POS transaction data together, the POS-DVR surveillance system provides

More information

Setup Manual and Programming Reference. RGA Ethernet Adapter. Stanford Research Systems. Revision 1.05 (11/2010)

Setup Manual and Programming Reference. RGA Ethernet Adapter. Stanford Research Systems. Revision 1.05 (11/2010) Setup Manual and Programming Reference Stanford Research Systems Revision 1.05 (11/2010) Certification Stanford Research Systems certifies that this product met its published specifications at the time

More information

IntesisBox ASCII Server - LON

IntesisBox ASCII Server - LON IntesisBox ASCII Server - LON Gateway for integration of LON devices into ASCII enabled control systems. Integrate Air Conditioning from the main manufacturers (DAIKIN, Mitsubishi Electric, Mitsubishi

More information

APR-PRT3 Printer Module: C-Bus Programming Instructions

APR-PRT3 Printer Module: C-Bus Programming Instructions APR-PRT3 Printer Module: C-Bus Programming Instructions We hope this product performs to your complete satisfaction. Should you have any questions or comments, please visit www.paradox.com and send us

More information

Allen-Bradley. Bar Code. 2-D Hand-Held. Programming Guide. Bar Code. Scanners. (Cat. No. 2755-HTG-4)

Allen-Bradley. Bar Code. 2-D Hand-Held. Programming Guide. Bar Code. Scanners. (Cat. No. 2755-HTG-4) Allen-Bradley 2-D Hand-Held Bar Code Scanners Bar Code Programming Guide (Cat. No. 2755-HTG-4) Important User Information The illustrations, charts, sample programs and layout examples shown in this guide

More information

Programming Flash Microcontrollers through the Controller Area Network (CAN) Interface

Programming Flash Microcontrollers through the Controller Area Network (CAN) Interface Programming Flash Microcontrollers through the Controller Area Network (CAN) Interface Application te Programming Flash Microcontrollers through the Controller Area Network (CAN) Interface Abstract This

More information

RFID MODULE Mifare Reader / Writer SL025B User Manual Version 1.4 Nov 2012 StrongLink

RFID MODULE Mifare Reader / Writer SL025B User Manual Version 1.4 Nov 2012 StrongLink RFID MODULE Mifare Reader / Writer User Manual Version 1.4 Nov 2012 StrongLink CONTENT 1. MAIN FEATURES... 3 2. PINNING INFORMATION... 4 3. BAUD RATE SETTING... 5 4. COMMUNICATION PROTOCOL... 5 4-1. COMMUNICATION

More information

Software User Guide UG-461

Software User Guide UG-461 Software User Guide UG-461 One Technology Way P.O. Box 9106 Norwood, MA 02062-9106, U.S.A. Tel: 781.329.4700 Fax: 781.461.3113 www.analog.com ezlinx icoupler Isolated Interface Development Environment

More information

OFF-LINE COMMUNICATIONS WITH CINCINNATI EQUIPMENT Pg. 1 of 5

OFF-LINE COMMUNICATIONS WITH CINCINNATI EQUIPMENT Pg. 1 of 5 Pg. 1 of MACHINE TYPE BACKGROUND CAPABILITIES SOFTWARE NEEDED* C. I. SOFTWARE AVAILABLE Autoform - VMEI NO Kermit - Off-Line Programming - -D Programming Autoform - VMEII YES Kermit - Same as above - D

More information

QuickScan i. QD2100 Barcode Imager. Product Reference Guide

QuickScan i. QD2100 Barcode Imager. Product Reference Guide QuickScan i QD2100 Barcode Imager Product Reference Guide Configuring the Interface KEYBOARD FEATURES AT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 95 w/standard Key Encoding Select KBD-AT Keyboard

More information

Modbus and ION Technology

Modbus and ION Technology 70072-0104-14 TECHNICAL 06/2009 Modbus and ION Technology Modicon Modbus is a communications protocol widely used in process control industries such as manufacturing. PowerLogic ION meters are compatible

More information

STIM202 Evaluation Kit

STIM202 Evaluation Kit Table of contents: 1 FEATURES... 2 2 GENERAL DESCRIPTIONS AND SYSTEM CONTENTS... 2 3 SYSTEM REQUIREMENTS... 2 4 GETTING STARTED... 3 4.1 INSTALLATION OF NI-SERIAL CABLE ASSEMBLY DRIVER... 3 4.2 INSTALLATION

More information

How to setup the UCW232C Serial WiFi adapter

How to setup the UCW232C Serial WiFi adapter How to setup the UCW232C Serial WiFi adapter (based on Windows 7, 32/64-bit) This step-by-step guide explains how to get started using the Serial RS232 WiFi Adapter part UCW232C and Serial RS485 / RS422

More information

RS232 Board datasheet

RS232 Board datasheet RS232 Board datasheet Contents 1. About this document 2. General information 3. Board Layout 4. Getting Started 5. Circuit Description Appendix 1 Circuit Diagram Copyright 2004 Matrix Multimedia Limited

More information

F2103 GPRS DTU USER MANUAL

F2103 GPRS DTU USER MANUAL F2103 GPRS DTU USER MANUAL Add:J1-J2,3rd Floor,No.44,GuanRi Road,SoftWare Park,XiaMen,China 1 Zip Code:361008 Contents Chapter 1 Brief Introduction of Product... 3 1.1 General... 3 1.2 Product Features...

More information

How To Connect A Directsofl To A Powerpoint With An Acd With An Ctel With An Dm-Tel Modem On A Pc Or Ipad Or Ipa (Powerpoint) With A Powerline 2 (Powerline

How To Connect A Directsofl To A Powerpoint With An Acd With An Ctel With An Dm-Tel Modem On A Pc Or Ipad Or Ipa (Powerpoint) With A Powerline 2 (Powerline Application Note Last reviewed: 03/17/2008 AN-KEP-003.doc Page 1 of 23 Introduction... 1 Recommended s and ports to use... 1 Cable Wiring... 2 MDM-TEL Configuration ( Wizard)... 3 Direct Logic Communications

More information

Toshiba Serial Driver Help. 2012 Kepware Technologies

Toshiba Serial Driver Help. 2012 Kepware Technologies 2012 Kepware Technologies 2 Table of Contents Table of Contents 2 3 Overview 3 Device Setup 4 Modem Setup 4 Cable Diagram - EX100/200 PLCs 4 Cable Diagram - T1 PLCs 5 Cable Diagram - T2/T3 PLCs 5 Cable

More information

THE SAS 16000 AUDIO ROUTING SWITCHER

THE SAS 16000 AUDIO ROUTING SWITCHER S A S 1 6 0 0 0 Audio Routing System 32 x 32 in a compact 2 RU package Multi-point RS-485 & RS-232 interfaces Stereo/mono easily integrated within system Many off-the-shelf interconnect options Superb

More information

Dial-Up / Leased-Line Modem. User Manual. AGM Electronics, Inc Dial-Up / Leased-Line Modem, Series ( ) 5019-1 Manual Rev A + - DLM CTS RTS DTR DSR

Dial-Up / Leased-Line Modem. User Manual. AGM Electronics, Inc Dial-Up / Leased-Line Modem, Series ( ) 5019-1 Manual Rev A + - DLM CTS RTS DTR DSR AGM Electronics, Inc Dial-Up / Leased-Line Modem, Series ( ) 5019-1 Manual Rev A User Manual + - CD CTS RTS DTR. DSR RI RX TX PHONE LINE DLM Dial-Up / Leased-Line Modem Dial-Up / Leased-Line Modem CONTENTS

More information

Arduino Wifi shield And reciever. 5V adapter. Connecting wifi module on shield: Make sure the wifi unit is connected the following way on the shield:

Arduino Wifi shield And reciever. 5V adapter. Connecting wifi module on shield: Make sure the wifi unit is connected the following way on the shield: the following parts are needed to test the unit: Arduino UNO R3 Arduino Wifi shield And reciever 5V adapter Connecting wifi module on shield: Make sure the wifi unit is connected the following way on the

More information

Configuring the Switch with the CLI Setup Program

Configuring the Switch with the CLI Setup Program APPENDIXC Configuring the Switch with the CLI Setup Program This appendix provides a command-line interface (CLI) setup procedure for a standalone switch. To set up the switch by using Express Setup, see

More information

ETHERNET WEATHER STATION CONNECTIONS Application Note 33

ETHERNET WEATHER STATION CONNECTIONS Application Note 33 ETHERNET WEATHER STATION CONNECTIONS Application Note 33 With WeatherLink and a Device Server INTRODUCTION It is possible to substitute an Ethernet connection for the direct USB or serial connection that

More information

Rev 06 1211. GSM base station. Installation instructions

Rev 06 1211. GSM base station. Installation instructions Rev 06 1211 GSM base station Installation instructions Output string format Baud rate 115200 bps Parity none Data bits 8 Stop bits 1 Flow control none The output string is a modified version of the Sureguard

More information

The Secrets of Flow Control in Serial Communication

The Secrets of Flow Control in Serial Communication in Serial Communication Casper Yang, Senior Product Manager support@moxa.com Although RS-232/422/485 serial communication is no longer considered to be high speed, flow control is still an important function

More information

Debugging Network Communications. 1 Check the Network Cabling

Debugging Network Communications. 1 Check the Network Cabling Debugging Network Communications Situation: you have a computer and your NetBurner device on a network, but you cannot communicate between the two. This application note provides a set of debugging steps

More information

Communications Instructions for DOOSAN, FANUC Controls

Communications Instructions for DOOSAN, FANUC Controls Communications Instructions for DOOSAN, FANUC Controls Ethernet & RS-232 for; 18i, 21i, 0ib and c 30i Series & 0id - 1 - Table of Contents Section 1... 3 Ethernet Set-up for the PC... 3 Description...

More information

Cisco Configuring Commonly Used IP ACLs

Cisco Configuring Commonly Used IP ACLs Table of Contents Configuring Commonly Used IP ACLs...1 Introduction...1 Prerequisites...2 Hardware and Software Versions...3 Configuration Examples...3 Allow a Select Host to Access the Network...3 Allow

More information

Controlling LifeSize Video Systems from the CLI

Controlling LifeSize Video Systems from the CLI Controlling LifeSize Video Systems from the CLI Use the LifeSize command line interface (CLI) to automate access and control of LifeSize video communications systems and LifeSize Phone with software release

More information

Part Number Description Packages available

Part Number Description Packages available Features 3 digital I/O Serial Data output Connects directly to RF Modules Easy Enc / Dec Pairing Function Minimal External Components Required Performs all encoding/decoding of data for Reliable Operation.

More information

User manual Compact Web PLC WP240 series IEC-line

User manual Compact Web PLC WP240 series IEC-line User manual Compact Web PLC WP240 series IEC-line update: 09-01-2014 IEC-line by OVERDIGIT overdigit.com 1. General description The WP240 device is a PLC, programmable in IEC61131-3 language using CoDeSys

More information

Consult protocol, Nissan Technical egroup, Issue 6

Consult protocol, Nissan Technical egroup, Issue 6 Consult protocol, Nissan Technical egroup, Issue 6 1. Electrical and Signaling protocol 1.1. Consult terminal or PC communications is via three wire bus. TX, RX and Async Clock. 1.2. TX data to ECU level

More information

LAN / WAN Connection Of Instruments with Serial Interface By Using a Terminal Server

LAN / WAN Connection Of Instruments with Serial Interface By Using a Terminal Server Products: EFA with EFA Scan, DVRM and DVMD with Realtime Monitor or Stream Explorer DVMD-B1 LAN / WAN Connection Of Instruments with Serial Interface By Using a Terminal Server Remote control of test and

More information

Using a Laptop Computer with a USB or Serial Port Adapter to Communicate With the Eagle System

Using a Laptop Computer with a USB or Serial Port Adapter to Communicate With the Eagle System Using a Laptop Computer with a USB or Serial Port Adapter to Communicate With the Eagle System ECU DB9 USB 20-060_A.DOC Page 1 of 18 9/15/2009 2009 Precision Airmotive LLC This publication may not be copied

More information

Data sheet Wireless UART firmware version 4.02

Data sheet Wireless UART firmware version 4.02 Data sheet Wireless UART firmware version 4.02 BLUETOOTH is a trademark owned by Bluetooth SIG, Inc., U.S.A. and licensed to Free2move Rev: 22 December 2008 Table of contents 1 GENERAL INFORMATION...4

More information

Using IDENT M System T with Modbus/TCP

Using IDENT M System T with Modbus/TCP Using IDENT M System T with Modbus/TCP Introduction The Pepperl+Fuchs IDENT M System T consists of two models MTT3000-F180-B12- V45-MON, which is a read only unit and the MTT6000-F120-B12-V45 which is

More information

IP Link Device Interface Communication Sheet

IP Link Device Interface Communication Sheet This document provides additional assistance with wiring your Extron IP Link enabled product to your device. Different components may require a different wiring scheme than those listed below. For complete

More information

Ethernet. Customer Provided Equipment Configuring the Ethernet port.

Ethernet. Customer Provided Equipment Configuring the Ethernet port. Installing the RDSP-3000A-NIST Master Clock. Ethernet Connect the RJ-45 connector to a TCP/IP network. Equipment The following equipment comes with the clock system: RDSP-3000A-NIST Master Clock Module.

More information

DSA-1000 / PRT-1000 Device Server / Thermal Printer

DSA-1000 / PRT-1000 Device Server / Thermal Printer LevelOne DSA-1000 / PRT-1000 Device Server / Thermal Printer User Manual V2.0 TABLE OF CONTENTS 1. INTRODUCTION...- 3-2. DEVICE OVERVIEW...- 7-3. HARDWARE SETUP...- 10-4. SYSTEM CONFIGURATION...- 12 -,

More information

HOST Embedded System. SLAVE EasyMDB interface. Reference Manual EasyMDB RS232-TTL. 1 Introduction

HOST Embedded System. SLAVE EasyMDB interface. Reference Manual EasyMDB RS232-TTL. 1 Introduction Reference Manual EasyMDB RS232-TTL 1 Introduction This document explains how to use the interface EasyMDB RS232-TTL and describe the connections and the necessary commands for communicating with Cash System

More information

SMS Alarm Messenger. Setup Software Guide. SMSPro_Setup. Revision 090210 [Version 2.2]

SMS Alarm Messenger. Setup Software Guide. SMSPro_Setup. Revision 090210 [Version 2.2] SMS Alarm Messenger SMSPro_Setup Revision 090210 [Version 2.2] ~ 1 ~ Contents 1. How to setup SMS Alarm Messenger?... 3 2. Install the SMSPro_Setup software... 5 3. Connection Type... 6 4. Connection Port

More information

TRP-C31M MODBUS TCP to RTU/ASCII Gateway

TRP-C31M MODBUS TCP to RTU/ASCII Gateway TRP-C31M MODBUS TCP to RTU/ASCII Gateway User s Manual Printed Feb. 2007 Rev 1.0 Trycom Technology Co., Ltd 1F, No.2-11, Sihu street, Yingge Township, Taipei, Taiwan ROC Tel: 886-2-86781191, Fax: 886-2-86781172

More information

4511 MODBUS RTU. Configuration Manual. HART transparent driver. No. 9107MCM100(1328)

4511 MODBUS RTU. Configuration Manual. HART transparent driver. No. 9107MCM100(1328) 4511 MODBUS RTU Configuration Manual HART transparent driver No. 9107MCM100(1328) 9107 CONTENTS Introduction... 3 Modbus basics... 3 Modbus RTU... 3 Supported Function Codes... 3 Modbus Parameters and

More information

BLUETOOTH SERIAL PORT PROFILE. iwrap APPLICATION NOTE

BLUETOOTH SERIAL PORT PROFILE. iwrap APPLICATION NOTE BLUETOOTH SERIAL PORT PROFILE iwrap APPLICATION NOTE Thursday, 19 April 2012 Version 1.2 Copyright 2000-2012 Bluegiga Technologies All rights reserved. Bluegiga Technologies assumes no responsibility for

More information

CNC File Transfer Box. Connecting the CNC File Transfer. CNC Transfer Program

CNC File Transfer Box. Connecting the CNC File Transfer. CNC Transfer Program CNC File Transfer Box The CNC File Transfer connects a serial CNC device to the network so files can be easily transferred from a computer to the CNC equipment. Any computer on the network can transfer

More information

RS-232 Communications Using BobCAD-CAM. RS-232 Introduction

RS-232 Communications Using BobCAD-CAM. RS-232 Introduction RS-232 Introduction Rs-232 is a method used for transferring programs to and from the CNC machine controller using a serial cable. BobCAD-CAM includes software for both sending and receiving and running

More information

Installing PowerLink on Windows 7 64-bit

Installing PowerLink on Windows 7 64-bit Instruction Manual Version 1.0, Code No. 20 751 806 1 Introduction... 3 2 Installing Virtual PC... 3 3 Configuring Windows XP Mode... 5 4 Installing Powerlink to Virtual XP... 8 5 Run PowerLink software

More information

Configuring Health Monitoring

Configuring Health Monitoring CHAPTER 6 This chapter describes how to configure the health monitoring on the CSM and contains these sections: Configuring Probes for Health Monitoring, page 6-1 Configuring Route Health Injection, page

More information

ENET-710. ENET-710 - Ethernet Module ENET-710 JAN / 06 FOUNDATION

ENET-710. ENET-710 - Ethernet Module ENET-710 JAN / 06 FOUNDATION ENET-710 ENET-710 - Ethernet Module JAN / 06 ENET-710 FOUNDATION E N E T 7 1 0 ME smar www.smar.com Specifications and information are subject to change without notice. Up-to-date address information is

More information

VM0808H HDMI Matrix Switch RS-232 Control Tool V1.0.064 User Manual

VM0808H HDMI Matrix Switch RS-232 Control Tool V1.0.064 User Manual VM0808H HDMI Matrix Switch RS-232 Control Tool V1.0.064 User Manual www.aten.com FCC Information This is an FCC Class A product. In a domestic environment this product may cause radio interference in which

More information

TASCAM SS-CDR200/SS-R200 CONTROL I/O Terminals RS-232C Protocol Specifications

TASCAM SS-CDR200/SS-R200 CONTROL I/O Terminals RS-232C Protocol Specifications TASCAM CONTROL I/O Terminals RS-232C Protocol Specifications TEAC Corporation - 1 - ATTENTION TEAC Corporation ("TEAC") licenses you the protocol specified in this document, assuming that you agree to

More information

IntesisBox KNX Modbus TCP master

IntesisBox KNX Modbus TCP master IntesisBox KNX TCP master Gateway for integration of TCP slave devices into KNX control systems. Integrate any TCP slave device into KNX. KNX TCP slave EIB Bus IntesisBox Ethernet slave LinkBoxEIB Configuration

More information

PROLOGIX GPIB-USB CONTROLLER USER MANUAL VERSION 6.107. May 14, 2013 PROLOGIX.BIZ

PROLOGIX GPIB-USB CONTROLLER USER MANUAL VERSION 6.107. May 14, 2013 PROLOGIX.BIZ PROLOGIX GPIB-USB CONTROLLER USER MANUAL VERSION 6.107 May 14, 2013 PROLOGIX.BIZ Table of Contents 1. Introduction... 4 2. Installation... 4 3. Firmware Upgrade... 4 4. Host Software... 4 5. Configuration...

More information

DigiLinX Application Note

DigiLinX Application Note Using RTI and other Universal Remotes to Control DigiLinX In DigiLinX Dealer Setup 2.3, NetStreams has introduced a new method of controlling DigiLinX from a 3 rd party control system called Serial2Command

More information

Advantech WebAccess Device Driver Guide. BwSNMP Advantech WebAccess to SNMP Agent (Simple Network Management Protocol) Device Driver Guide

Advantech WebAccess Device Driver Guide. BwSNMP Advantech WebAccess to SNMP Agent (Simple Network Management Protocol) Device Driver Guide BwSNMP Advantech WebAccess to SNMP Agent (Simple Network Management Protocol) Device Driver Guide Version 5.0 rev 1 Advantech Corp., Ltd. Table of Contents BwSNMP Advantech WebAccess to SNMP Agent (Simple

More information

How to setup a serial Bluetooth adapter

How to setup a serial Bluetooth adapter 2U www. How to setup a serial Bluetooth adapter Master Setup Guide For part numbers UCBT232B and UCBT232EXA UPairing the serial Bluetooth adapter with your computer UPairing with Windows 10.. 2U UPairing

More information

Broadband Router ESG-103. User s Guide

Broadband Router ESG-103. User s Guide Broadband Router ESG-103 User s Guide FCC Warning This equipment has been tested and found to comply with the limits for Class A & Class B digital device, pursuant to Part 15 of the FCC rules. These limits

More information

Data Bulletin. Communications Wiring for POWERLINK G3 Systems Class 1210 ABOUT THIS BULLETIN APPLICATION INTRODUCTION.

Data Bulletin. Communications Wiring for POWERLINK G3 Systems Class 1210 ABOUT THIS BULLETIN APPLICATION INTRODUCTION. Data Bulletin 1210DB0002R3/05 03/2005 LaVergne, TN, USA Communications Wiring for POWERLINK G3 Systems Class 1210 Retain for future use. ABOUT THIS BULLETIN This data bulletin describes the proper wiring

More information

IP SERIAL DEVICE SERVER

IP SERIAL DEVICE SERVER IP SERIAL DEVICE SERVER ( 1 / 2 / 4 serial port ) Installation guide And User manual Version 1.0 1Introduction... 5 1.1Direct IP mode...5 1.2Virtual COM mode...5 1.3Paired mode...6 1.4Heart beat... 6

More information