Timeout The Crosspoint Status Request message has a timeout, which means that you need to wait 1 second in between request messages.
|
|
- Ambrose Powell
- 7 years ago
- Views:
Transcription
1 Network Control Protocol Important notes Binary Code The strings shown on the next pages are in binary coded format. Please be aware that any terminal program you may use to control a Network unit from a PC must be able to generate hexadecimal characters. ASCII characters will not be accepted. Acknowledge / Echo A matrix will reply on a crosspoint set command with an ECHO. In the case where a crosspoint is already set, no ECHO will be sent. If the matrix is part of a Network Control Bus system two types of reply will be sent. Immediately after receiving the crosspoint set command the ECHO will be sent. The matrix will then wait for the command to pass the Network Control Bus system. After receiving the command from the Network Control Bus system the matrix will send the command as an ACKNOWLEDGE. Network Control Protocol Important notes Binary Code The strings shown on the next pages are in binary coded format. Please be aware that any terminal program you may use to control a Network unit from a PC must be able to generate hexadecimal characters. ASCII characters will not be accepted. Acknowledge / Echo A matrix will reply on a crosspoint set command with an ECHO. In the case where a crosspoint is already set, no ECHO will be sent. If the matrix is part of a Network Control Bus system two types of reply will be sent. Immediately after receiving the crosspoint set command the ECHO will be sent. The matrix will then wait for the command to pass the Network Control Bus system. After receiving the command from the Network Control Bus system the matrix will send the command as an ACKNOWLEDGE. Timeout The Crosspoint Status Request message has a timeout, which means that you need to wait 1 second in between request messages. Audio crosspoint set Only for use with Audio Routers. Command for setting of crosspoints: 1001nnnn 0kkk kkkk 0vvv vvvv nnnn is the matrix address from 0 up to 15. kkk kkkk is the output which shall be controlled. o kkk kkkk = output number o 0 = output 1 o 127 = output 128 vvv vvvv is the input which shall be connected to the chosen output. o vvv vvvv = input number Crosspoint status request This command is used for status request on Audio and Video Routers. 1100nnnn 0xxxxxxx nnnn is the matrix address from 0 up to 15. xxxxxxx - do not carry any information The requested Router (Audio or Video) will send its crosspoint status on MIDI OUT and RS232. The same
2 command format as for crosspoint set is used. Video crosspoint set Only for use with Video Routers. Command for setting of crosspoints: 1010nnnn 0kkkkkkk 0vvvvvvv nnnn is the matrix address from 0 up to 15. kkk kkkk is the output which shall be controlled. o kkk kkkk = output number o 0 = output 1 o 127 = output 128 vvv vvvv is the input which shall be connected to the chosen output. vvv vvvv = input number Interface protocol RS232 The RS-232 port is used for external control of VikinX units. The RS-232 port allows the customer to control the equipment via Network s PC Software THOR or self-defined customised solutions. Connector for the RS-232 port is a DS9 female. Pin 2 - Tx. Pin 3 - Rx Pin 5 - GND A standard DCE (Data Communication Equipment) cable can be used for connection between PC and Network equipment. The connection between the connectors is made one-to-one. Data-rate is baud. 8 data-bit, 1 stop-bit, no parity.
3 Appendix N Jupiter ASCII Communications Protocol Revision E 1/11/2000 Hardware connections for an external computer are shown on page Set up in the Jupiter Control System File Server includes defining one or more port pairs as being ASCII in the Serial Protocol Table (page 5 26). The control computer is identified on the MPK Devices table (page 5 130). You will need to define each port as being type Serial, and give each port a CP Level, Input, and Output Set. These sets will determine which levels, inputs, and outputs are available to each ASCII port to control and status. The ASCII Computer Interface is assigned to a SC 3000, SI 3000, or VM 3000 serial port pair and uses a simple ASCII data format defined below. The serial protocol defaults to 9600 Baud, 8 Data Bits, No Parity, and 1 Stop Bit. Baud rates of 2400, 4800, 19.2K and 38.4K are also user configurable from the Jupiter Control System File Server. The control port uses XON (0x11) and XOFF (0x13) to control command pacing if necessary. All commands are in upper case ASCII. Space (0x20) characters are optional and will be ignored. Each command is followed by a carriage return (0x0D). If a line feed (0x0A) is included it must follow the carriage return. The controlling computer must take care to wait for a ZY or ZN response after each command before attempting to send a subsequent command. Failure to do so will result in a ZN response, and possibly an XOFF condition. If switcher status is received, wait for all levels to be statused before sending another command. Here is a key to help you understand the following command descriptions: OOO > Router Switcher OUTPUT. This corresponds with the Selection number defined in this AS- CII port s CP Output Set. The range is from 000 to 999. (Previous releases had a range from 000 to 249.) III > Router Switcher INPUT. This corresponds with the Selection number defined in this ASCII port s CP Input Set. (Previous releases had a range from 000 to 249.) N 1
4 ASCII Protocol LLLLLLL > Router Switcher LEVELS. This corresponds with a logical position in this ASCII port s CP Level Set. The range is from 1 to 7. For example, 1 refers to the first entry in the CP Level Set, and 5 refers to the fifth entry in that same set. If no levels are specified, then the take is assumed to apply to all levels defined in that set. Level number entries are NOT position dependent. ASCII General Purpose Commands ZA Acknowledge This command is used to see if the ASCII interface exists and is running. A response of ZA is returned whenever a ZA is received. ZZ Reset This command forces the ASCII controller to reset. This causes the interface to cancel all previous ZP, ZV, and ZW commands. A ZX response is returned to the external computer upon command completion. This ZX is also returned whenever the interface is manually reset. ZY Command Accepted This response is returned after the serial port has (ACK) successfully parsed the command and in the case of a switch command has successfully issued the TAKE to the system and received a switch response back from the system. This does NOT mean that the command was successfully executed. The remote computer should not issue a new command until receiving a ZY or ZN from the current command. The amount of time for the response will vary depending on system complexity and current system activity. Also the number of switches involved in the command will affect the amount of time it takes to receive the ZY response. Multiple switches sent in one command may result in ZR response(s) being returned before the ZY response. ZN Command Rejected A ZN will be issued when a condition occurs where (NAK) the current command cannot be executed. A ZN response can be issued for several reasons such as an invalid com- N 2
5 ASCII Protocol mand, an invalid command format, or an invalid input, output or level. Invalid inputs, outputs and levels are logged to the system logger. Also if the system is busy a ZN will be issued followed by XOFF. When it is again ready for the next command a XON will be issued. Note that after the XON, response(s) from the prior command may be issued (e.g. ZR response(s)). Router Switcher Control and Status Commands ZSOOOIIILLLLLLL Switch Request This command causes the interface to issue a TAKE Switch Request to the routing switcher control system and affects a single routing switcher output. If no levels are specified, then ALL defined levels are assumed. Note: Passwords are not honored by automation protocol handling. A remote computer can send a command with multiple Switch Requests (older releases do not have this capability). A single command can be up to 180 characters long which allows switching of from outputs (depending on the specified levels). An example of a multiple Switch Request follows: ZS ZS ZS <CR> This example command would switch outputs 0, 1, and 2 on levels 1 and 2. ZROOO Status Request This command requests current switcher status for a single output. The response is in the format: ZROOOIIILLLLLLL. If the status for the output is split, multiple responses will be returned. ZWOOO Watch Output This command causes the interface to watch the specified output for any changes and report such changes. A request to watch output 999 is a request to watch all defined N 3
6 ASCII Protocol outputs in that port s serial output set. All responses are in the ZR format described above. When issued, this command also may result in an immediate ZR response for the requested output(s). No ZR response(s) will be returned if the requested output(s) do not have any inputs assigned to them. ZPOOO Lock Output This command LOCKS the specified output from being changed by any system control device. ZVOOO Protect Output This command PROTECTS the specified output from being changed by any other system control device. ZUOOO Unlock Output This command removes the LOCK or PROTECT from the specified system output. If another system control device or interface locked or protected this output, this command will fail. ZJOOO Report Lock Status This command will return a code based on which kind of system control device or interface LOCKED or PRO- TECTED the specified output. If the output is not locked or protected, no response will be sent. The response codes are as follows: ZJ000 ZJ ZJ999 Jupiter Control Panel Party Line Control Panel THIS ASCII INTERFACE Note: Lock status returned for the first level only in the CP Level Set for this ASCII port. N 4
CONCEPT1 RS232 COMMUNICATION
Concept 1 RS-232 Communication Communication with Concept 1 via RS-232 is done with simple ASCII Commands and Replies. The port settings are 19200Baud, 8bits, no parity and 1 stop bit. The physical connection
More informationRouter Connection Details
Router Connection Details Television Systems Limited. Vanwall Road, Maidenhead, Berkshire, SL6 4UB Telephone +44 (0)1628 676200, FAX +44 (0)1628 676299 1 Routers Contents 1 GVG Encore / Prelude / Jupiter
More informationPM1122 INT DIGITAL INTERFACE REMOTE
PM1122 INT DIGITAL INTERFACE REMOTE PM1122 INT front panel description: 1. Clear wireless remotes knob: push this button for more than 2 seconds to clear the list of all assigned wireless remote settings
More informationUsing HyperTerminal with Agilent General Purpose Instruments
Using HyperTerminal with Agilent General Purpose Instruments Windows HyperTerminal can be used to program most General Purpose Instruments (not the 531xx series counters) using the RS-232 Serial Bus. Instrument
More informationSUDT AccessPort TM Advanced Terminal / Monitor / Debugger Version 1.37 User Manual
SUDT AccessPort TM Advanced Terminal / Monitor / Debugger Version 1.37 User Manual Version 1.0 - January 20, 2015 CHANGE HISTORY Version Date Description of Changes 1.0 January 20, 2015 Initial Publication
More informationBIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter
BIT COMMANDER Serial RS232 / RS485 to Ethernet Converter (Part US2000A) Copyrights U.S. Converters 1 Contents Overview and Features... 3 Functions..5 TCP Server Mode... 5 Httpd Client Mode.5 TCP Auto mode....6
More informationApplication Bulletin
INTELLIGENT CONTROLS INC PO BOX 638 34 SPRING HILL RD SACO, ME 04072 U S A Application Bulletin 000-2045 REV. B Retrieving Tap Change Indication Data from an INCON1250B via an SEL 2020 or 2030 Communications
More informationLTM-1338B. Plus Communications Manual
LTM-1338B Plus Communications Manual 2000. Best Power, Necedah, Wisconsin All rights reserved. Best Power The System Setup option from the Main Menu on the front panel is passwordprotected. The default
More informationMCB3101 (Class I) WiRobot Serial Bluetooth Wireless Module User Manual
MCB3101 (Class I) WiRobot Serial Bluetooth Wireless Module User Manual Version: 1.0.1 Dec. 2005 Table of Contents I. Introduction 2 II. Operations 2 II.1. Theory of Operation 2 II.2. Configuration (PC-PC
More informationLS-101 LAN to Serial Device server. User s Manual
LS-101 LAN to Serial Device server User s Manual Revision History Revision No Date Author Remarks 0.1 August 29, 2001 IDC Initial document INTRODUCTION Overview Almost all instruments and most industrial
More informationTo perform Ethernet setup and communication verification, first perform RS232 setup and communication verification:
PURPOSE Verify that communication is established for the following products programming option (488.2 compliant, SCPI only): DCS - M9C & DCS M130, DLM M9E & DLM-M9G & DLM M130, DHP - M9D, P series, SG,
More informationPRT3 Printer Module: ASCII Protocol Programming Instructions
PRT3 Printer Module: ASCII Protocol Programming Instructions We hope this product performs to your complete satisfaction. Should you have any questions or comments, please visit www.paradox.com and send
More informationVirtual Integrated Design Getting started with RS232 Hex Com Tool v6.0
Virtual Integrated Design Getting started with RS232 Hex Com Tool v6.0 Copyright, 1999-2007 Virtual Integrated Design, All rights reserved. 1 Contents: 1. The Main Window. 2. The Port Setup Window. 3.
More informationWhen we look at the connector pinout of the RS232 port, we see two pins which are certainly used
1 Null modem - an introduction Serial communications with RS232 1. One of the oldest and most widely spread communication methods in computer world. The way this type of communication can be performed
More informationModbus Communications for PanelView Terminals
User Guide Modbus Communications for PanelView Terminals Introduction This document describes how to connect and configure communications for the Modbus versions of the PanelView terminals. This document
More informationisco Connecting Routers Back to Back Through the AUX P
isco Connecting Routers Back to Back Through the AUX P Table of Contents Connecting Routers Back to Back Through the AUX Ports...1 Introduction...1 Before You Begin...1 Conventions...1 Prerequisites...1
More informationCENTRONICS interface and Parallel Printer Port LPT
Course on BASCOM 8051 - (37) Theoretic/Practical course on BASCOM 8051 Programming. Author: DAMINO Salvatore. CENTRONICS interface and Parallel Printer Port LPT The Parallel Port, well known as LPT from
More informationSingle channel data transceiver module WIZ2-434
Single channel data transceiver module WIZ2-434 Available models: WIZ2-434-RS: data input by RS232 (±12V) logic, 9-15V supply WIZ2-434-RSB: same as above, but in a plastic shell. The WIZ2-434-x modules
More informationESPA 4.4.4 Nov 1984 PROPOSAL FOR SERIAL DATA INTERFACE FOR PAGING EQUIPMENT CONTENTS 1. INTRODUCTION 2. CHARACTER DESCRIPTION
PROPOSAL FOR SERIAL DATA INTERFACE FOR PAGING EQUIPMENT CONTENTS 1. INTRODUCTION 2. CHARACTER DESCRIPTION 2.1 CHARACTER STRUCTURE 2.2 THE CHARACTER SET 2.3 CONTROL CHARACTERS 2.3.1 Transmission control
More informationSYMETRIX SOLUTIONS: TECH TIP August 2015
String Output Modules The purpose of this document is to provide an understanding of operation and configuration of the two different String Output modules available within SymNet Composer. The two different
More informationRS232C < - > RS485 CONVERTER S MANUAL. Model: LD15U. Phone: 91-79-4002 4896 / 97 / 98 (M) 0-98253-50221 www.interfaceproducts.info
RS232C < - > RS485 CONVERTER S MANUAL Model: LD15U INTRODUCTION Milestone s model LD-15U is a RS232 to RS 485 converter is designed for highspeed data transmission between computer system and or peripherals
More informationTAP Interface Specifications
TAP Interface Specifications This Document is for those who want to develop their own paging control software or add an interface for the WaveWare v9 Series Paging Encoder to their existing software applications.
More informationHow to setup a serial Bluetooth adapter Master Guide
How to setup a serial Bluetooth adapter Master Guide Nordfield.com Our serial Bluetooth adapters part UCBT232B and UCBT232EXA can be setup and paired using a Bluetooth management software called BlueSoleil
More informationProgramming and Using the Courier V.Everything Modem for Remote Operation of DDF6000
Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000 1.0 Introduction A Technical Application Note from Doppler System July 5, 1999 Version 3.x of the DDF6000, running version
More informationIntroduction: Implementation of the MVI56-MCM module for modbus communications:
Introduction: Implementation of the MVI56-MCM module for modbus communications: Initial configuration of the module should be done using the sample ladder file for the mvi56mcm module. This can be obtained
More informationSoftware Manual RS232 Laser Merge Module. Document # SU-256521-09 Rev A
Laser Merge Module Document # SU-256521-09 Rev A The information presented in this document is proprietary to Spectral Applied Research Inc. and cannot be used for any purpose other than that for which
More informationTCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL
TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL w w w. c d v g r o u p. c o m CA-ETHR-A: TCP/IP Module Installation Manual Page Table of Contents Introduction...5 Hardware Components... 6 Technical Specifications...
More informationKnowledge Base Article. Integrating ISONAS Access Control System with TagMaster LR-series RFID Readers
Knowledge Base Article Integrating ISONAS Access Control System with TagMaster LR-series RFID Readers Copyright 2009-2012, ISONAS Security Systems All rights reserved Table of Contents 1: INTRODUCTION...
More informationINTRODUCTION FEATURES OF THE ICM
INTRODUCTION The ICM, Internet Control Module, is a remote controller device accessible via the Internet that allows operational access to the IPS (and other base units available). Through the ICM you
More informationSenseLink TM. End-Point Controller. Addendum
SenseLink TM End-Point Controller Addendum MKS Instruments, Inc. Control & Information Technology Products Group 3350 Scott Blvd Bldg 4 Santa Clara, CA 95054 Main: 408.235.7620 Fax: 408.235.7625 SenseLink
More informationTable 1 below is a complete list of MPTH commands with descriptions. Table 1 : MPTH Commands. Command Name Code Setting Value Description
MPTH: Commands Table 1 below is a complete list of MPTH commands with descriptions. Note: Commands are three bytes long, Command Start Byte (default is 128), Command Code, Setting value. Table 1 : MPTH
More informationASCII CONTROL COMMANDS FOR MATRIX SWITCHING SYSTEMS AN_0001
APPLICATION NOTE ASCII CONTROL COMMANDS FOR MATRIX SWITCHING SYSTEMS AN_0001 TABLE OF CONTENTS Section GENERAL DESCRIPTION 1.0 CAMERA TO MONITOR CALL-UP 2.0 TOUR/SEQUENCE CONTROL 3.0 PAN/TILT/LENS CONTROL
More informationSmarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier INTRODUCTION
Smarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier INTRODUCTION The Smarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier is a multi-functional compact device. It
More informationModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.
IntesisBox ModBus Server - KNX Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems. Integrate KNX based lighting control into your SCADA, BMS, PLC "talking" Modbus. Master
More informationControlling the projector using a personal computer
AUDIO OUT AUDIO IN-1 AUDIO IN-2 AUDIO IN-3L AUDIO IN-3R S-VIDEO VIDEO SERIAL MONITOR OUT COMPUTER / COMPONENT VIDEO IN-1 IN-2 USB-B USB-A TM DLP Projector MODEL XD550U/XD560U/WD570U/XD360U-EST/WD380U-EST
More informationInternet-bridge XPort
Ing. Z.Královský Ing. Petr Štol Perk 457 Okrajová 1356 675 22 STA 674 01 T EBÍ Development & production of control equipment Tel.: 568 870982 Tel.: 568 848179 Visualization, measurement and regulation
More informationUSER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: 2900-300321 Rev 6
KRAMER ELECTRONICS LTD. USER GUIDE Ethernet Configuration Guide (Lantronix) P/N: 2900-300321 Rev 6 Contents 1 Connecting to the Kramer Device via the Ethernet Port 1 1.1 Connecting the Ethernet Port Directly
More informationFINS Gateway For OMRON PLCs
1 Purpose This Technical Note describes how to set up a remote collaboration. A remote collaboration consists in configuring, programming or monitoring a PLC from a remote location, without the need of
More informationThe Answer to the 14 Most Frequently Asked Modbus Questions
Modbus Frequently Asked Questions WP-34-REV0-0609-1/7 The Answer to the 14 Most Frequently Asked Modbus Questions Exactly what is Modbus? Modbus is an open serial communications protocol widely used in
More informationUser Manual. AS-Interface Programmer
AS-Interface Programmer Notice: RESTRICTIONS THE ZMD AS-INTERFACE PROGRAMMER HARDWARE AND ZMD AS-INTERFACE PROGRAMMER SOFTWARE IS DESIGNED FOR IC EVALUATION, LABORATORY SETUP AND MODULE DEVELOPMENT ONLY.
More informationBluetooth HC-06 with serial port module Easy guide
1 Bluetooth HC-06 with serial port module Easy guide This manual consists of 3 parts: PART 1. Overview of Bluetooth HC-06 module with serial port. PART 2. Installing Bluetooth HC-06 module with Bolt 18F2550
More informationUsing Bluetooth-Enabled PosiTector 6000 with Statistical Process Control Software
Using Bluetooth-Enabled PosiTector 6000 with Statistical Process Control Software SPC programs are available from third party vendors that enhance the measurement capabilities of the PosiTector 6000. With
More information1.1 Connection. 1.1.1 Direct COM port connection. 1. Half duplex RS232 spy cable without handshaking
POS function Marchen POS-DVR surveillance system is a professional surveillance integrated with POS system. By bringing video and POS transaction data together, the POS-DVR surveillance system provides
More informationSetup Manual and Programming Reference. RGA Ethernet Adapter. Stanford Research Systems. Revision 1.05 (11/2010)
Setup Manual and Programming Reference Stanford Research Systems Revision 1.05 (11/2010) Certification Stanford Research Systems certifies that this product met its published specifications at the time
More informationIntesisBox ASCII Server - LON
IntesisBox ASCII Server - LON Gateway for integration of LON devices into ASCII enabled control systems. Integrate Air Conditioning from the main manufacturers (DAIKIN, Mitsubishi Electric, Mitsubishi
More informationAPR-PRT3 Printer Module: C-Bus Programming Instructions
APR-PRT3 Printer Module: C-Bus Programming Instructions We hope this product performs to your complete satisfaction. Should you have any questions or comments, please visit www.paradox.com and send us
More informationAllen-Bradley. Bar Code. 2-D Hand-Held. Programming Guide. Bar Code. Scanners. (Cat. No. 2755-HTG-4)
Allen-Bradley 2-D Hand-Held Bar Code Scanners Bar Code Programming Guide (Cat. No. 2755-HTG-4) Important User Information The illustrations, charts, sample programs and layout examples shown in this guide
More informationProgramming Flash Microcontrollers through the Controller Area Network (CAN) Interface
Programming Flash Microcontrollers through the Controller Area Network (CAN) Interface Application te Programming Flash Microcontrollers through the Controller Area Network (CAN) Interface Abstract This
More informationRFID MODULE Mifare Reader / Writer SL025B User Manual Version 1.4 Nov 2012 StrongLink
RFID MODULE Mifare Reader / Writer User Manual Version 1.4 Nov 2012 StrongLink CONTENT 1. MAIN FEATURES... 3 2. PINNING INFORMATION... 4 3. BAUD RATE SETTING... 5 4. COMMUNICATION PROTOCOL... 5 4-1. COMMUNICATION
More informationSoftware User Guide UG-461
Software User Guide UG-461 One Technology Way P.O. Box 9106 Norwood, MA 02062-9106, U.S.A. Tel: 781.329.4700 Fax: 781.461.3113 www.analog.com ezlinx icoupler Isolated Interface Development Environment
More informationOFF-LINE COMMUNICATIONS WITH CINCINNATI EQUIPMENT Pg. 1 of 5
Pg. 1 of MACHINE TYPE BACKGROUND CAPABILITIES SOFTWARE NEEDED* C. I. SOFTWARE AVAILABLE Autoform - VMEI NO Kermit - Off-Line Programming - -D Programming Autoform - VMEII YES Kermit - Same as above - D
More informationQuickScan i. QD2100 Barcode Imager. Product Reference Guide
QuickScan i QD2100 Barcode Imager Product Reference Guide Configuring the Interface KEYBOARD FEATURES AT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 95 w/standard Key Encoding Select KBD-AT Keyboard
More informationModbus and ION Technology
70072-0104-14 TECHNICAL 06/2009 Modbus and ION Technology Modicon Modbus is a communications protocol widely used in process control industries such as manufacturing. PowerLogic ION meters are compatible
More informationSTIM202 Evaluation Kit
Table of contents: 1 FEATURES... 2 2 GENERAL DESCRIPTIONS AND SYSTEM CONTENTS... 2 3 SYSTEM REQUIREMENTS... 2 4 GETTING STARTED... 3 4.1 INSTALLATION OF NI-SERIAL CABLE ASSEMBLY DRIVER... 3 4.2 INSTALLATION
More informationHow to setup the UCW232C Serial WiFi adapter
How to setup the UCW232C Serial WiFi adapter (based on Windows 7, 32/64-bit) This step-by-step guide explains how to get started using the Serial RS232 WiFi Adapter part UCW232C and Serial RS485 / RS422
More informationRS232 Board datasheet
RS232 Board datasheet Contents 1. About this document 2. General information 3. Board Layout 4. Getting Started 5. Circuit Description Appendix 1 Circuit Diagram Copyright 2004 Matrix Multimedia Limited
More informationF2103 GPRS DTU USER MANUAL
F2103 GPRS DTU USER MANUAL Add:J1-J2,3rd Floor,No.44,GuanRi Road,SoftWare Park,XiaMen,China 1 Zip Code:361008 Contents Chapter 1 Brief Introduction of Product... 3 1.1 General... 3 1.2 Product Features...
More informationHow To Connect A Directsofl To A Powerpoint With An Acd With An Ctel With An Dm-Tel Modem On A Pc Or Ipad Or Ipa (Powerpoint) With A Powerline 2 (Powerline
Application Note Last reviewed: 03/17/2008 AN-KEP-003.doc Page 1 of 23 Introduction... 1 Recommended s and ports to use... 1 Cable Wiring... 2 MDM-TEL Configuration ( Wizard)... 3 Direct Logic Communications
More informationToshiba Serial Driver Help. 2012 Kepware Technologies
2012 Kepware Technologies 2 Table of Contents Table of Contents 2 3 Overview 3 Device Setup 4 Modem Setup 4 Cable Diagram - EX100/200 PLCs 4 Cable Diagram - T1 PLCs 5 Cable Diagram - T2/T3 PLCs 5 Cable
More informationTHE SAS 16000 AUDIO ROUTING SWITCHER
S A S 1 6 0 0 0 Audio Routing System 32 x 32 in a compact 2 RU package Multi-point RS-485 & RS-232 interfaces Stereo/mono easily integrated within system Many off-the-shelf interconnect options Superb
More informationDial-Up / Leased-Line Modem. User Manual. AGM Electronics, Inc Dial-Up / Leased-Line Modem, Series ( ) 5019-1 Manual Rev A + - DLM CTS RTS DTR DSR
AGM Electronics, Inc Dial-Up / Leased-Line Modem, Series ( ) 5019-1 Manual Rev A User Manual + - CD CTS RTS DTR. DSR RI RX TX PHONE LINE DLM Dial-Up / Leased-Line Modem Dial-Up / Leased-Line Modem CONTENTS
More informationArduino Wifi shield And reciever. 5V adapter. Connecting wifi module on shield: Make sure the wifi unit is connected the following way on the shield:
the following parts are needed to test the unit: Arduino UNO R3 Arduino Wifi shield And reciever 5V adapter Connecting wifi module on shield: Make sure the wifi unit is connected the following way on the
More informationConfiguring the Switch with the CLI Setup Program
APPENDIXC Configuring the Switch with the CLI Setup Program This appendix provides a command-line interface (CLI) setup procedure for a standalone switch. To set up the switch by using Express Setup, see
More informationETHERNET WEATHER STATION CONNECTIONS Application Note 33
ETHERNET WEATHER STATION CONNECTIONS Application Note 33 With WeatherLink and a Device Server INTRODUCTION It is possible to substitute an Ethernet connection for the direct USB or serial connection that
More informationRev 06 1211. GSM base station. Installation instructions
Rev 06 1211 GSM base station Installation instructions Output string format Baud rate 115200 bps Parity none Data bits 8 Stop bits 1 Flow control none The output string is a modified version of the Sureguard
More informationThe Secrets of Flow Control in Serial Communication
in Serial Communication Casper Yang, Senior Product Manager support@moxa.com Although RS-232/422/485 serial communication is no longer considered to be high speed, flow control is still an important function
More informationDebugging Network Communications. 1 Check the Network Cabling
Debugging Network Communications Situation: you have a computer and your NetBurner device on a network, but you cannot communicate between the two. This application note provides a set of debugging steps
More informationCommunications Instructions for DOOSAN, FANUC Controls
Communications Instructions for DOOSAN, FANUC Controls Ethernet & RS-232 for; 18i, 21i, 0ib and c 30i Series & 0id - 1 - Table of Contents Section 1... 3 Ethernet Set-up for the PC... 3 Description...
More informationCisco Configuring Commonly Used IP ACLs
Table of Contents Configuring Commonly Used IP ACLs...1 Introduction...1 Prerequisites...2 Hardware and Software Versions...3 Configuration Examples...3 Allow a Select Host to Access the Network...3 Allow
More informationControlling LifeSize Video Systems from the CLI
Controlling LifeSize Video Systems from the CLI Use the LifeSize command line interface (CLI) to automate access and control of LifeSize video communications systems and LifeSize Phone with software release
More informationPart Number Description Packages available
Features 3 digital I/O Serial Data output Connects directly to RF Modules Easy Enc / Dec Pairing Function Minimal External Components Required Performs all encoding/decoding of data for Reliable Operation.
More informationUser manual Compact Web PLC WP240 series IEC-line
User manual Compact Web PLC WP240 series IEC-line update: 09-01-2014 IEC-line by OVERDIGIT overdigit.com 1. General description The WP240 device is a PLC, programmable in IEC61131-3 language using CoDeSys
More informationConsult protocol, Nissan Technical egroup, Issue 6
Consult protocol, Nissan Technical egroup, Issue 6 1. Electrical and Signaling protocol 1.1. Consult terminal or PC communications is via three wire bus. TX, RX and Async Clock. 1.2. TX data to ECU level
More informationLAN / WAN Connection Of Instruments with Serial Interface By Using a Terminal Server
Products: EFA with EFA Scan, DVRM and DVMD with Realtime Monitor or Stream Explorer DVMD-B1 LAN / WAN Connection Of Instruments with Serial Interface By Using a Terminal Server Remote control of test and
More informationUsing a Laptop Computer with a USB or Serial Port Adapter to Communicate With the Eagle System
Using a Laptop Computer with a USB or Serial Port Adapter to Communicate With the Eagle System ECU DB9 USB 20-060_A.DOC Page 1 of 18 9/15/2009 2009 Precision Airmotive LLC This publication may not be copied
More informationData sheet Wireless UART firmware version 4.02
Data sheet Wireless UART firmware version 4.02 BLUETOOTH is a trademark owned by Bluetooth SIG, Inc., U.S.A. and licensed to Free2move Rev: 22 December 2008 Table of contents 1 GENERAL INFORMATION...4
More informationUsing IDENT M System T with Modbus/TCP
Using IDENT M System T with Modbus/TCP Introduction The Pepperl+Fuchs IDENT M System T consists of two models MTT3000-F180-B12- V45-MON, which is a read only unit and the MTT6000-F120-B12-V45 which is
More informationIP Link Device Interface Communication Sheet
This document provides additional assistance with wiring your Extron IP Link enabled product to your device. Different components may require a different wiring scheme than those listed below. For complete
More informationEthernet. Customer Provided Equipment Configuring the Ethernet port.
Installing the RDSP-3000A-NIST Master Clock. Ethernet Connect the RJ-45 connector to a TCP/IP network. Equipment The following equipment comes with the clock system: RDSP-3000A-NIST Master Clock Module.
More informationDSA-1000 / PRT-1000 Device Server / Thermal Printer
LevelOne DSA-1000 / PRT-1000 Device Server / Thermal Printer User Manual V2.0 TABLE OF CONTENTS 1. INTRODUCTION...- 3-2. DEVICE OVERVIEW...- 7-3. HARDWARE SETUP...- 10-4. SYSTEM CONFIGURATION...- 12 -,
More informationHOST Embedded System. SLAVE EasyMDB interface. Reference Manual EasyMDB RS232-TTL. 1 Introduction
Reference Manual EasyMDB RS232-TTL 1 Introduction This document explains how to use the interface EasyMDB RS232-TTL and describe the connections and the necessary commands for communicating with Cash System
More informationSMS Alarm Messenger. Setup Software Guide. SMSPro_Setup. Revision 090210 [Version 2.2]
SMS Alarm Messenger SMSPro_Setup Revision 090210 [Version 2.2] ~ 1 ~ Contents 1. How to setup SMS Alarm Messenger?... 3 2. Install the SMSPro_Setup software... 5 3. Connection Type... 6 4. Connection Port
More informationTRP-C31M MODBUS TCP to RTU/ASCII Gateway
TRP-C31M MODBUS TCP to RTU/ASCII Gateway User s Manual Printed Feb. 2007 Rev 1.0 Trycom Technology Co., Ltd 1F, No.2-11, Sihu street, Yingge Township, Taipei, Taiwan ROC Tel: 886-2-86781191, Fax: 886-2-86781172
More information4511 MODBUS RTU. Configuration Manual. HART transparent driver. No. 9107MCM100(1328)
4511 MODBUS RTU Configuration Manual HART transparent driver No. 9107MCM100(1328) 9107 CONTENTS Introduction... 3 Modbus basics... 3 Modbus RTU... 3 Supported Function Codes... 3 Modbus Parameters and
More informationBLUETOOTH SERIAL PORT PROFILE. iwrap APPLICATION NOTE
BLUETOOTH SERIAL PORT PROFILE iwrap APPLICATION NOTE Thursday, 19 April 2012 Version 1.2 Copyright 2000-2012 Bluegiga Technologies All rights reserved. Bluegiga Technologies assumes no responsibility for
More informationCNC File Transfer Box. Connecting the CNC File Transfer. CNC Transfer Program
CNC File Transfer Box The CNC File Transfer connects a serial CNC device to the network so files can be easily transferred from a computer to the CNC equipment. Any computer on the network can transfer
More informationRS-232 Communications Using BobCAD-CAM. RS-232 Introduction
RS-232 Introduction Rs-232 is a method used for transferring programs to and from the CNC machine controller using a serial cable. BobCAD-CAM includes software for both sending and receiving and running
More informationInstalling PowerLink on Windows 7 64-bit
Instruction Manual Version 1.0, Code No. 20 751 806 1 Introduction... 3 2 Installing Virtual PC... 3 3 Configuring Windows XP Mode... 5 4 Installing Powerlink to Virtual XP... 8 5 Run PowerLink software
More informationConfiguring Health Monitoring
CHAPTER 6 This chapter describes how to configure the health monitoring on the CSM and contains these sections: Configuring Probes for Health Monitoring, page 6-1 Configuring Route Health Injection, page
More informationENET-710. ENET-710 - Ethernet Module ENET-710 JAN / 06 FOUNDATION
ENET-710 ENET-710 - Ethernet Module JAN / 06 ENET-710 FOUNDATION E N E T 7 1 0 ME smar www.smar.com Specifications and information are subject to change without notice. Up-to-date address information is
More informationVM0808H HDMI Matrix Switch RS-232 Control Tool V1.0.064 User Manual
VM0808H HDMI Matrix Switch RS-232 Control Tool V1.0.064 User Manual www.aten.com FCC Information This is an FCC Class A product. In a domestic environment this product may cause radio interference in which
More informationTASCAM SS-CDR200/SS-R200 CONTROL I/O Terminals RS-232C Protocol Specifications
TASCAM CONTROL I/O Terminals RS-232C Protocol Specifications TEAC Corporation - 1 - ATTENTION TEAC Corporation ("TEAC") licenses you the protocol specified in this document, assuming that you agree to
More informationIntesisBox KNX Modbus TCP master
IntesisBox KNX TCP master Gateway for integration of TCP slave devices into KNX control systems. Integrate any TCP slave device into KNX. KNX TCP slave EIB Bus IntesisBox Ethernet slave LinkBoxEIB Configuration
More informationPROLOGIX GPIB-USB CONTROLLER USER MANUAL VERSION 6.107. May 14, 2013 PROLOGIX.BIZ
PROLOGIX GPIB-USB CONTROLLER USER MANUAL VERSION 6.107 May 14, 2013 PROLOGIX.BIZ Table of Contents 1. Introduction... 4 2. Installation... 4 3. Firmware Upgrade... 4 4. Host Software... 4 5. Configuration...
More informationDigiLinX Application Note
Using RTI and other Universal Remotes to Control DigiLinX In DigiLinX Dealer Setup 2.3, NetStreams has introduced a new method of controlling DigiLinX from a 3 rd party control system called Serial2Command
More informationAdvantech WebAccess Device Driver Guide. BwSNMP Advantech WebAccess to SNMP Agent (Simple Network Management Protocol) Device Driver Guide
BwSNMP Advantech WebAccess to SNMP Agent (Simple Network Management Protocol) Device Driver Guide Version 5.0 rev 1 Advantech Corp., Ltd. Table of Contents BwSNMP Advantech WebAccess to SNMP Agent (Simple
More informationHow to setup a serial Bluetooth adapter
2U www. How to setup a serial Bluetooth adapter Master Setup Guide For part numbers UCBT232B and UCBT232EXA UPairing the serial Bluetooth adapter with your computer UPairing with Windows 10.. 2U UPairing
More informationBroadband Router ESG-103. User s Guide
Broadband Router ESG-103 User s Guide FCC Warning This equipment has been tested and found to comply with the limits for Class A & Class B digital device, pursuant to Part 15 of the FCC rules. These limits
More informationData Bulletin. Communications Wiring for POWERLINK G3 Systems Class 1210 ABOUT THIS BULLETIN APPLICATION INTRODUCTION.
Data Bulletin 1210DB0002R3/05 03/2005 LaVergne, TN, USA Communications Wiring for POWERLINK G3 Systems Class 1210 Retain for future use. ABOUT THIS BULLETIN This data bulletin describes the proper wiring
More informationIP SERIAL DEVICE SERVER
IP SERIAL DEVICE SERVER ( 1 / 2 / 4 serial port ) Installation guide And User manual Version 1.0 1Introduction... 5 1.1Direct IP mode...5 1.2Virtual COM mode...5 1.3Paired mode...6 1.4Heart beat... 6
More information