WELLHEAD FLOWLINE PRESSURE PROTECTION USING HIGH INTEGRITY PROTECTIVE SYSTEMS (HIPS)
|
|
|
- Cora Lyons
- 9 years ago
- Views:
Transcription
1 WELLHEAD FLOWLINE PRESSURE PROTECTION USING HIGH INTEGRITY PROTECTIVE SYSTEMS (HIPS) Angela E. Summers, Ph.D., P.E., President, SIS-Tech Solutions, LP Bryan A. Zachary, Director, Product & Application Engineering, SIS-TECH Solutions, LP Abstract For many years, owner/operator pipe specification practices have required that wellhead downstream piping be adequate to sustain a full wellhead shut-in. This inherently safer design practice ensured that flowline pipe was specified with a maximum allowable working pressure (MAWP) equal to or greater than the maximum pressure expected to be produced by the well. This practice has been proven to provide adequate protection in thousands of wellhead installations throughout the world. Inherently safer practice has been challenged recently with the introduction of electric submersible pumps (ESPs) in new and existing wells. The maximum discharge pressure under block-in conditions is greater than the MAWP of existing flowline pipe. A safe alternative to replacing the pipe is the use of a high integrity protective system (HIPS) designed and managed as a safety instrumented system (SIS). While the HIPS protects the flowline, the implementation of the HIPS introduces a new cause for blocked ESP discharge, which can result in significant ESP damage and production losses. This new hazard scenario must be addressed in the overall risk reduction strategy for the ESP and pipeline. This presentation explains how HIPS can be applied as a layer of protection against flowline overpressure in single and multiple wellhead installations. It also discusses how HIPS implementation affects the necessary ESP protection. Introduction An enhanced oil recovery solution, especially in ultra deep (4,000 ft.) subsea applications, is to utilize electric submersible pumps (ESP) to boost well pressure. Reasons given for installing an ESP include: Older, sometimes abandoned, wells still contain valuable oil reserves but insufficient pressure for efficient recovery, Connecting wells with different production pressures to common manifolds, Desire to increase production rates, and Existing production wells are being connected to more distant processing facilities. A major challenge in developing these deepwater enhanced oil recovery solutions is the maximum allowable working pressure (MAWP) limitation of the downstream flowline pipe. Conventional wellhead piping practice requires that downstream piping be adequate to sustain a full wellhead shut-in. This practice has proven to be safe and effective in thousands of wellhead installations throughout the world. However, Featherwood Drive Suite 120 Tel: (281) Fax: (281)
2 Page 2 of 7 the introduction of high pressure ESPs in many off-shore fields has increased the maximum shut-in pressure beyond the MAWP of the downstream flowline pipe. A safe and reliable alternative to replacing the existing wellhead flowlines relies on the use of a High Integrity Protective Systems (HIPS) to detect unacceptable operating pressure and initiate closure of block valves upstream of the flowline specification break, protecting the lower rated piping downstream. This solution is gaining acceptance with the latest release of API 521 providing guidance on its implementation and the Minerals Management Service (MMS) approving HIPS as a new technology application for off-shore installations in the Gulf of Mexico. A HIPS (Figure 1) is a special class of safety instrumented system (SIS), which should be designed and managed according to ISA /IEC The term high integrity is a reference to the amount of risk reduction typically required from the SIS in these applications. HIPS are generally assigned a target safety integrity level (SIL) of SIL 2 or SIL 3. HIPS are used when there are no other practical means to address pressure events through mechanical design. Figure 1. High Integrity Protective System High Integrity Protective Systems are Safety Instrumented Systems (SIS) designed and managed to achieve high integrity (e.g., SIL 2 or SIL 3) The major elements of these systems are: Sensor(s): Detect abnormal operating conditions (over/under pressure, temperature, flow, etc.). Logic solver: Electrical/Electronic/Programmable Electronic System that process input conditions and change outputs to initiate final element action. Final element(s): Take the process to the safe state. Figure 1. High Integrity Protective System The HIPS can be designed to protect against pressure challenges from single wells or multiple wells attached to a single flowline. When the HIPS takes action, it protects the flowline by initiating wellhead shut-in, which in the event of a high pressure situation is a sound and appropriate action to take. If the HIPS acts without cause, or spuriously operates, the HIPS action results in significant economic losses from lost production. Consequently, the HIPS should be designed to be highly reliable in addition to providing high integrity for operation on demand. Redundant user-approved equipment and frequent maintenance are generally necessary to achieve these requirements. HIPS design should consider the fast system response time necessary to act within the available process safety time. On wellhead shut-in, the ESP typically produces pressure sufficient to challenge the mechanical integrity of the flowline very quickly. The pressure rise is related to the compressibility of the material, but the pressure rise is generally rapid, resulting in a very short process safety time. For example, in liquid service, the time may be less than 5 seconds. For wellhead protection, the greatest challenge to successful HIPS implementation is the long-term inspection, preventive maintenance, and proof testing required to maintain the equipment in the as good as new condition. With numerous locations scattered across large areas, owner/operators require that the
3 Page 3 of 7 equipment be maintainable by the local workforce and be environmentally robust. These requirements, in combination with the low number of inputs and outputs, favor an electrical system, using relays or trip amplifiers. Finally, the HIPS design requires careful consideration for common cause, common mode, and systematic failures. This increases when networks of flowlines with multiple HIPS are involved and fast response times are required. When multiple HIPS functions are placed in the same logic solver, the logic solver becomes a single point of failure for the spurious shutdown of multiple wells and for dangerous failure resulting in overpressure of the flowline downstream of the pipe specification break. The probability of failure on demand (PFD) can be calculated for the HIPS using the data for the operating environment. Example data is provided in Figure 2. Figure 2. Assumptions used in calculations Equipment (MTTFD): Pressure transmitter (150 years) Trip amplifier (715 years) Solenoid operated valve (60 years) Block valve (60 years) Diagnostics: Detected faults for transmitters result in the transmitter failing to the safe state, causing the channel to vote to trip. For 2oo3 voting, the process remains on-line, because two votes to trip are required for shutdown to occur. The vote to trip initiates an alarm on the operator interface, so that maintenance is initiated in a timely fashion. The operator responds to the alarm according to a written procedure. Common cause: 2% for pressure transmitters and trip amplifiers 0.2% for the solenoid operated valve and block valve Test interval: 1 year Single well protection The production from a single well can be improved through the installation of an ESP. The production increase comes with a new hazard; the potential overpressure of the flowline on ESP shut-in. The hazard is present any time there is a flowline blockage downstream of the pipe specification break, such as closure of the boarding valve. A HIPS can be implemented to prevent this higher pressure from propagating to the lower MAWP specification flowline by isolating the pressure source upstream of the pipe specification break. The HIPS illustrated in Figure 3 uses two out of the three (2oo3) pressure transmitters to detect high pressure in the flowline. The logic solver outputs initiate shutdown of the block valves located upstream of the pipe specification break. The final element action prevents overpressure and possible rupture of the flowline.
4 Page 4 of 7 The same sensors can be used to detect flowline rupture or significant flowline leakage, and the same final element action can be taken with the block valves to isolate the flowline stopping the release. While closing the block valves protects the flowline against upstream pressure, it causes a cascade event - the ESP shut-in. The piping between the ESP and the block valves is fully rated and presents little possibility for loss of containment. However, blocking the ESP discharge can damage the ESP. The pump discharge can become blocked by various errors and failures, such as the boarding valve closing, the HIPS taking action on process demand, or either block valve failing closed spuriously. The losses associated with ESP replacement normally justify the expense of an automated ESP shutdown using an instrumented system classified as an asset protection system. The ESP protection can be accomplished by: Measuring the discharge pressure upstream of the block valves and shutting off the ESP protects pump against all causes of block-in downstream of the pressure transmitter whether identified or not Monitoring the valve position with limit switches and shutting off the ESP when either valve closes this protect against closure of the block valves but no other sources of block-in downstream can be a spurious trip problem; limit switches are notorious Initiating ESP shutdown when HIPS takes action often distance between HIPS and ESP is too great protects ESP (economic), so it can be sent back via communications (SCADA); not as reliable first option above Figure 3. Single well installation as: The overall risk reduction strategy for the single well installation shown in Figure 3 can be defined Prevent flow line rupture: Close block valves on 2oo3 high pressure to isolate the pressure source. PFD=4.472E-04, which meets SIL 3 Detect flowline rupture: Close block valves on 2oo3 low pressure to isolate wellhead. PFD=4.472E-04, which meets SIL 3
5 Page 5 of 7 Prevent pump damage: Shutdown the pump on high discharge pressure. PFD=4.769E-03, which meets APL 2. On further consideration, the need to protect the pump has now resulted in a new protection layer for high pressure. Preventing flowline rupture starts at the pressure source -- the ESP. The ESP protection could be reclassified as an SIS and implemented as part of the flowline protection strategy. The ESP protection detects high pressure on the ESP discharge and takes action to stop the ESP. The pressure propagates down the pipeline if the ESP shutdown does not work. The presence of high flowline pressure initiates closure of the block valves. If the two systems are implemented in separate SISs, the HIPS predicted performance greatly exceeds the required risk reduction. If any components are shared by both SISs, these components must be designed and managed to support the overall required risk reduction, Multiple well protection Many fields contain multiple wells that should be assessed as part of a network. When multiple wells are involved, the analysis and design become more complex. In the illustration (Figure 4), there are four ESPs that can overpressure the flowline when the boarding valve closes. Wellhead networks can easily exceed four interconnected wellheads. Figure 4. Four networked wells protected by individual HIPS As more wells become networked, the risk to the flowline becomes increasingly larger. It also becomes harder to achieve the required risk reduction for the flowline protection. The PFD of the network can be approximated as 4 x 4.472E-04 = 1.789E-03, if separate and independent non-pe logic solvers are used. Even with separate SISs, the network PFD still does not meet SIL 3. As the network grows in size, the protection provided to the flowline by the HIPS declines further. Since the individual HIPS block the discharge of their respective ESP, the asset risk is similar to a single wellhead. When the ESP protection is reclassified as an SIS, the flowline protection can be provided by two independent SISs. The overall risk reduction provided by the two independent SISs exceeds the requirements. Again, if any components are shared by both SISs, these components must be designed and managed to support the overall required risk reduction,
6 Page 6 of 7 An alternative process design (Figure 5) moves the flowline specification break to the header. This increases the amount of piping that must be rated for maximum ESP discharge pressure. The HIPS consists of a single SIS isolating the header on high pressure. The PFD meets 4.472E-04, which is the same the single well case. When the single HIPS acts, it blocks the discharge of multiple ESPs, resulting in multiple ESPs being damaged and for multiple wellheads to cease production. As with the single well case, the implementation of individual ESP protection systems prevents flowline rupture, since each isolates the pressure source. The ESP trips also reduce the potential ESP damage and business losses from the multiple wellhead isolation, because the SIS on the flowline would only act if the ESP trip did not operate properly. If the ESP trip malfunctions, the only choice is to protect the flowline, block the ESP s discharge, and accept ESP damage. When the ESP trip is considered part of the HIPS, the predicted performance of the HIPS exceeds risk reduction requirements. Figure 5 Four networked wells protected by single HIPS Conclusions An effective risk reduction strategy can only be developed based on an understanding of the overall risk to the process equipment. The overall risk includes the risk associated with the initiating cause propagating to the final consequence and the risk associated with secondary events initiated by the chosen risk reduction strategy. A single well can be protected using a dedicated HIPS, consisting of 2oo3 pressure transmitters, 2oo3 trip amplifiers, and 1oo2 block valves. With annual testing, the PFD meets SIL 3 requirements. As more wells are networked, the flowline risk is increased and the HIPS design becomes more complicated. When multiple, individual wellheads must be protected, it can become difficult to meet the high integrity requirements expected of HIPS. When the pipe specification break is moved to a main flowline, the network of wellheads can be protected by a single HIPS, which meets desired risk reduction.
7 Page 7 of 7 When a trip is added to protect the ESP from damage due to blocked discharge, a new solution to meeting the risk reduction requirements is identified. The ESP protection can be classified as an SIS and implemented as part of the HIPS strategy. The use of two independent SIS makes it possible to achieve the high risk reduction requirements. Reference IEC 61511, Functional Safety: Safety Instrumented Systems for the Process Industry Sector, International Electrotechnical Commission, Geneva, Switzerland (2003). ANSI/ISA (IEC modified), Functional Safety: Safety Instrumented Systems for the Process Industry Sector, Instrumentation, Systems, and Automation Society, Research Triangle Park, NC (2004). ANSI/API 521, Petroleum and Natural Gas Industries Pressure-relieving and depressing systems, American Petroleum Institute, API Publishing Services, Washington, DC (2007). Minerals Management Services, Approval of Implementation of New Technology for High Integrity Pressure Protection Systems (HIPPS), MS 5220, Letter to Ms Susan Wilson, BP Exploration & Production Inc, from Donald C. Howard, Minerals Management Services (June ).
USING INSTRUMENTED SYSTEMS FOR OVERPRESSURE PROTECTION. Dr. Angela E. Summers, PE. SIS-TECH Solutions, LLC Houston, TX
USING INSTRUMENTED SYSTEMS FOR OVERPRESSURE PROTECTION By Dr. Angela E. Summers, PE SIS-TECH Solutions, LLC Houston, TX Prepared for Presentation at the 34 th Annual Loss Prevention Symposium, March 6-8,
Viewpoint on ISA TR84.0.02 Simplified Methods and Fault Tree Analysis Angela E. Summers, Ph.D., P.E., President
Viewpoint on ISA TR84.0.0 Simplified Methods and Fault Tree Analysis Angela E. Summers, Ph.D., P.E., President Presented at Interkama, Dusseldorf, Germany, October 1999, Published in ISA Transactions,
Safety controls, alarms, and interlocks as IPLs
Safety controls, alarms, and interlocks as IPLs Angela E. Summers, Ph.D., P.E. SIS-TECH Solutions 12621 Featherwood Dr. Suite 120, Houston, TX 77034 Keywords: safety controls, alarms, interlocks, SIS,
SOFTWARE-IMPLEMENTED SAFETY LOGIC Angela E. Summers, Ph.D., P.E., President, SIS-TECH Solutions, LP
SOFTWARE-IMPLEMENTED SAFETY LOGIC Angela E. Summers, Ph.D., P.E., President, SIS-TECH Solutions, LP Software-Implemented Safety Logic, Loss Prevention Symposium, American Institute of Chemical Engineers,
HIPPS Application in the Gulf of Mexico. Christopher Lindsey-Curran BP Senior Subsea Engineer
HIPPS Application in the Gulf of Mexico Christopher Lindsey-Curran BP Senior Subsea Engineer Agenda Introduction and background HIPPS overview Codes and standards System design Regulatory issues Conclusions
A PROCESS ENGINEERING VIEW OF SAFE AUTOMATION
A PROCESS ENGINEERING VIEW OF SAFE AUTOMATION Published in Chemical Engineering Progress, December 2008. Angela E. Summers, SIS-TECH Solutions, LP This step-by-step procedure applies instrumented safety
Understanding Safety Integrity Levels (SIL) and its Effects for Field Instruments
Understanding Safety Integrity Levels (SIL) and its Effects for Field Instruments Introduction The Industrial process industry is experiencing a dynamic growth in Functional Process Safety applications.
Basic Fundamentals Of Safety Instrumented Systems
September 2005 DVC6000 SIS Training Course 1 Basic Fundamentals Of Safety Instrumented Systems Overview Definitions of basic terms Basics of safety and layers of protection Basics of Safety Instrumented
Safety Requirements Specification Guideline
Safety Requirements Specification Comments on this report are gratefully received by Johan Hedberg at SP Swedish National Testing and Research Institute mailto:[email protected] -1- Summary Safety Requirement
Final Element Architecture Comparison
Final Element Architecture Comparison 2oo2 with diagnostics: Lower False Trip Rate and High Safety Project: Safety Cycling Systems Architecture Review Customer: Safety Cycling Systems, L.L.C. 1018 Laurel
Setting a Global Standard. www.dril-quip.com. HIPPS: High Integrity Pressure Protection System
Setting a Global Standard www.dril-quip.com HIPPS: High Integrity Pressure Protection System HIPPS: High Integrity Pressure Protection System As deeper reservoirs are drilled and discovered offshore, production
SAFETY LIFE-CYCLE HOW TO IMPLEMENT A
AS SEEN IN THE SUMMER 2007 ISSUE OF... HOW TO IMPLEMENT A SAFETY LIFE-CYCLE A SAFER PLANT, DECREASED ENGINEERING, OPERATION AND MAINTENANCE COSTS, AND INCREASED PROCESS UP-TIME ARE ALL ACHIEVABLE WITH
Selecting Sensors for Safety Instrumented Systems per IEC 61511 (ISA 84.00.01 2004)
Selecting Sensors for Safety Instrumented Systems per IEC 61511 (ISA 84.00.01 2004) Dale Perry Worldwide Pressure Marketing Manager Emerson Process Management Rosemount Division Chanhassen, MN 55317 USA
Logic solver application software and operator interface
Logic solver application software and operator interface By RJ Perry, Control Systems Consultant Correctly implemented and structured functional logic, together with operator interface displays, can improve
Hardware safety integrity Guideline
Hardware safety integrity Comments on this report are gratefully received by Johan Hedberg at SP Swedish National Testing and Research Institute mailto:[email protected] Quoting of this report is allowed
Version: 1.0 Latest Edition: 2006-08-24. Guideline
Management of Comments on this report are gratefully received by Johan Hedberg at SP Swedish National Testing and Research Institute mailto:[email protected] Quoting of this report is allowed but please
ESTIMATION AND EVALUATION OF COMMON CAUSE FAILURES IN SIS
ESTIMATION AND EVALUATION OF COMMON CAUSE FAILURES IN SIS Angela E. Summers, Ph.D., Director Kimberly A. Ford, Senior Risk Analyst, and Glenn Raney, Technical Specialist Premier Consulting + Engineering,
A methodology For the achievement of Target SIL
A methodology For the achievement of Target SIL Contents 1.0 Methodology... 3 1.1 SIL Achievement - A Definition... 4 1.2 Responsibilities... 6 1.3 Identification of Hazards and SIL Determination... 8
Fisher FIELDVUE Instrumentation Improving Safety Instrumented System Reliability
Fisher FIELDVUE Instrumentation Improving Safety Instrumented System Reliability 2 Improving Safety Instrumented System Reliability Improving Safety Instrumented System Reliability 3 Safety Instrumented
FMEDA and Proven-in-use Assessment. Pepperl+Fuchs GmbH Mannheim Germany
FMEDA and Proven-in-use Assessment Project: Inductive NAMUR sensors Customer: Pepperl+Fuchs GmbH Mannheim Germany Contract No.: P+F 03/11-10 Report No.: P+F 03/11-10 R015 Version V1, Revision R1.1, July
SAFETY LIFECYCLE WORKBOOK FOR THE PROCESS INDUSTRY SECTOR
SAFETY LIFECYCLE WORKBOOK FOR THE PROCESS INDUSTRY SECTOR SAFETY LIFECYCLE WORKBOOK FOR THE PROCESS INDUSTRY SECTOR The information and any recommendations that may be provided herein are not intended
Safety Integrity Level (SIL) Assessment as key element within the plant design
Safety Integrity Level (SIL) Assessment as key element within the plant design Tobias WALK ILF Consulting Engineers GmbH Germany Abstract Special attention has to be provide to safety instrumented functions
Master Class. Electrical and Instrumentation (E &I) Engineering for Oil and Gas Facilities
Master Class Electrical and Instrumentation (E &I) Engineering for Oil and Gas Facilities What you will learn: Skills and competencies in E&I oil and gas engineering Knowledge of the latest technologies
Michael A. Mitchell, Cameron Flow Control, DYNATORQUE Product Manager
SIL Made Simple Michael A. Mitchell, Cameron Flow Control, DYNATORQUE Product Manager KEY WORDS: Safety Integrity Level (SIL) Safety Instrumented Systems (SIS) ISA 84.01, IEC 61511 Partial Stroke Test
Is Cost Effective Compliance with the IEC61511 Safety Lifecycle Sustainable?
Is Cost Effective Compliance with the IEC61511 Safety Lifecycle Sustainable? Michael Scott, PE, CFSE Exec VP - Global Process Safety Technology aesolutions Carolyn Presgraves, CFSP Senior Director of Software
Value Paper Author: Edgar C. Ramirez. Diverse redundancy used in SIS technology to achieve higher safety integrity
Value Paper Author: Edgar C. Ramirez Diverse redundancy used in SIS technology to achieve higher safety integrity Diverse redundancy used in SIS technology to achieve higher safety integrity Abstract SIS
Effective Compliance. Selecting Solenoid Valves for Safety Systems. A White Paper From ASCO Valve, Inc. by David Park and George Wahlers
Effective Compliance with IEC 61508 When Selecting Solenoid Valves for Safety Systems by David Park and George Wahlers A White Paper From ASCO Valve, Inc. Introduction Regulatory modifications in 2010
Safety Integrated. SIMATIC Safety Matrix. The Management Tool for all Phases of the Safety Lifecycle. Brochure September 2010. Answers for industry.
SIMATIC Safety Matrix The Management Tool for all Phases of the Safety Lifecycle Brochure September 2010 Safety Integrated Answers for industry. Functional safety and Safety Lifecycle Management Hazard
DeltaV SIS for Burner Management Systems
January 2011 Page 1 DeltaV SIS for Burner Management Systems RESULTS Inhibit startup when unsafe conditions exist Protect against unsafe operating conditions, including improper fuel quantities Provide
Overview of IEC 61508 - Design of electrical / electronic / programmable electronic safety-related systems
Overview of IEC 61508 - Design of electrical / electronic / programmable electronic safety-related systems Simon Brown The author is with the Health & Safety Executive, Magdalen House, Bootle, Merseyside,
Reduce Risk with a State-of-the-Art Safety Instrumented System. Executive Overview... 3. Risk Reduction Is the Highest Priority...
ARC WHITE PAPER By ARC Advisory Group SEPTEMBER 2004 Reduce Risk with a State-of-the-Art Safety Instrumented System Executive Overview... 3 Risk Reduction Is the Highest Priority... 4 Safety Standards
Select the Right Relief Valve - Part 1 Saeid Rahimi
Select the Right Relief Valve - Part 1 Saeid Rahimi 8-Apr-01 Introduction Selecting a proper type of relief valve is an essential part of an overpressure protection system design. The selection process
Functional safety. Essential to overall safety
Functional safety Essential to overall safety What is Functional safety? In public spaces, factories, offi ces or homes; we are surrounded by an increasing number of electric and electronic devices and
SIL in de praktijk (Functional Safety) 23.04.2015 - Antwerpen. 61508 Compliance of Actuators and Life Cycle Considerations. SAMSON AG Dr.
SIL in de praktijk (Functional Safety) 23.04.2015 - Antwerpen SAMSON AG Dr. Thomas Karte 61508 Compliance of Actuators and Life Cycle Considerations 2015-04-23 SAMSON AG Dr. Karte - 61508 Compliance of
Hydraulic Pipeline Application Modules PSI s Tools to Support Pipeline Operation
Hydraulic Pipeline Application Modules PSI s Tools to Support Pipeline Operation Inhalt 1 Leak Detection and Location Modules... 3 1.1 Dynamic Balance Leak Detection... 3 1.2 Transient Model Leak Detection...
Version: 1.0 Last Edited: 2005-10-27. Guideline
Process hazard and risk Comments on this report are gratefully received by Johan Hedberg at SP Swedish National Testing and Research Institute mailto:[email protected] -1- Summary This report will try
Failure Modes, Effects and Diagnostic Analysis
Failure Modes, Effects and Diagnostic Analysis Project: Plant-STOP 9475 Company: R. STAHL Schaltgeräte GmbH Waldenburg Germany Contract No.: STAHL 13/04-027 Report No.: STAHL 13/04-027 R024 Version V1,
SIS 401 - Smart SIS 15 minutes
2005 Emerson Process Management. All rights reserved. View this and other courses online at www.plantwebuniversity.com. SIS 401 - Smart SIS 15 minutes In this course: 1 Overview 2 Why It Matters 3 What
Fig. 2 Option 1 Integrated Design using Physical Separation. Fig. 1 Standard Modular Process Skid Design Concept
Modular Integration of Process Equipment Packages for Oil and Gas Facilities Copyright Material PCIC Europe Paper No. PCIC Europe XXXX Allan Bozek EngWorks, Inc. 1620 49 th Avenue, SW Calgary, AB T2T 2T7
Take a modern approach to increase safety integrity while improving process availability. DeltaV SIS Process Safety System
Take a modern approach to increase safety integrity while improving process availability. DeltaV SIS Process Safety System Whether standalone or integrated, choose a smart, modern safety system designed
Why SIL3? Josse Brys TUV Engineer [email protected]
Why SIL3? Josse Brys TUV Engineer [email protected] Agenda Functional Safety Good planning if specifications are not right? What is the difference between a normal safety and SIL3 loop? How do systems achieve
THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.
THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS. NOT ALL CODES ARE POSSIBLE ON ANY INDIVIDUAL UNIT. IF THE ALARM APPLIES
SAFETY MANUAL SIL SMART Transmitter Power Supply
PROCESS AUTOMATION SAFETY MANUAL SIL SMART Transmitter Power Supply KFD2-STC4-(Ex)*, KFD2-STV4-(Ex)*, KFD2-CR4-(Ex)* ISO9001 2 3 With regard to the supply of products, the current issue of the following
Mary Ann Lundteigen. Doctoral theses at NTNU, 2009:9 Mary Ann Lundteigen. Doctoral theses at NTNU, 2009:9
Mary Ann Lundteigen Doctoral theses at NTNU, 2009:9 Mary Ann Lundteigen Safety instrumented systems in the oil and gas industry: Concepts and methods for safety and reliability assessments in design and
By Steven C. Severini, P.E., Member ASHRAE
The following article was published in ASHRAE Journal, July 2004. Copyright 2004 American Society of Heating, Refrigerating and Air- Conditioning Engineers, Inc. It is presented for educational purposes
IEC 61508 Functional Safety Assessment. ASCO Numatics Scherpenzeel, The Netherlands
IEC 61508 Functional Safety Assessment Project: Series 327 Solenoid Valves Customer: ASCO Numatics Scherpenzeel, The Netherlands Contract No.: Q09/04-59 Report No.: ASC 09-04-59 R003 V1 R3 61508 Assessment
MAINTENANCE INSTRUCTIONS. Thermia Robust heat pump
MAINTENANCE INSTRUCTIONS Thermia Robust heat pump 9 6 8 0-5 4 7 4 5 0 0 1 R e v. 3 Table of contents 1 Important information.................. 2 1.1 Product description....................... 2 1.2 General................................
Safety Integrity Level (SIL) Studies Germanischer Lloyd Service/Product Description
Safety & Risk Management Services Safety Integrity Level (SIL) Studies Germanischer Lloyd Service/Product Description Germanischer Lloyd Service/Product Description Safety Integrity Level (SIL) Studies
www.klmtechgroup.com TABLE OF CONTENT
Page : 1 of 13 Project Engineering Standard www.klmtechgroup.com KLM Technology #03-12 Block Aronia, Jalan Sri Perkasa 2 Taman Tampoi Utama 81200 Johor Bahru Malaysia TABLE OF CONTENT SCOPE 2 REFERENCES
RecipCOM. Expertise, reciprocating compressor monitoring and protection tailored to your needs
RecipCOM Expertise, reciprocating compressor monitoring and protection tailored to your needs Do your reciprocating compressors have sufficient protection? Due to the increasing demands on availability
Competitive Edge through System Engineering
Competitive Edge through System Engineering KBD Forum 6-7 March 2013 Tore Halvorsen FMC Technologies 0 Floating Production Partial Subsea Processing Subsea Systems today: the enabler for deepwater developments
A practical guide to restrictive flow orifices
Safetygram 46 A practical guide to restrictive flow orifices Restrictive flow orifices (RFOs) installed in cylinder valve outlets provide a significant safety benefit for users of hazardous gases, especially
B r u ne n r e Ma M n a a n g a e g m e e m n e t A S t S rai a gh g t h for o wa w r a d A p p r p oa o c a h c h Us U i s ng n g De D l e tav a
Burner Management A Straightforward Approach Using DeltaV SIS for Typical Systems David Sheppard, CFSE Presentation: SIS, BMS, Why Implement BMS in a SIS State Transition Approach to BMS Design Review
Fiscal Measurement Natural Gas
White Paper FSG-WP-0012 February 2014 Fiscal Measurement Natural Gas Fiscal Measurement How much? Fiscal Measurement must not be confused with Custody Transfer; in fact, fiscal measurement is a more general
MXa SIL Guidance and Certification
MXa SIL Guidance and Certification SIL 3 capable for critical applications Experience In Motion Functional Safety in Plants Safety and instrumentation engineers demand that a functional safety system s
SAFETY MANUAL SIL SWITCH AMPLIFIER
PROCESS AUTOMATION SAFETY MANUAL SIL SWITCH AMPLIFIER KF**-SR2-(Ex)*(.LB), KFD2-SR2-(Ex)2.2S ISO9001 2 With regard to the supply of products, the current issue of the following document is applicable:
SAFETY MANUAL SIL Switch Amplifier
PROCESS AUTOMATION SAFETY MANUAL SIL Switch Amplifier KCD2-SR-(Ex)*(.LB)(.SP), HiC282* ISO9001 2 With regard to the supply of products, the current issue of the following document is applicable: The General
Electric heat tracing
PIPELINE DESIGN Figure 1. Shorter, more complex piping at a process plant. Electric heat tracing Neil Malone, Heat Trace, UK, discusses electric heat tracing of long pipelines. In considering electric
Digital Wellsite Prognostic Health Monitoring
Digital Wellsite Prognostic Health Monitoring Digital Wellsite Prognostic Health Monitoring It has been suggested that asset digitization could cut operational costs by 10 15% and potentially boost production
Fault codes DM1. Industrial engines DC09, DC13, DC16. Marine engines DI09, DI13, DI16 INSTALLATION MANUAL. 03:10 Issue 5.0 en-gb 1
Fault codes DM1 Industrial engines DC09, DC13, DC16 Marine engines DI09, DI13, DI16 03:10 Issue 5.0 en-gb 1 DM1...3 Abbreviations...3 Fault type identifier...3...4 03:10 Issue 5.0 en-gb 2 DM1 DM1 Fault
V-MAC III Fault Assignments
V-MAC III Fault Assignments ELECTRICAL FAULTS Stp Circuit Failure Blink Sequence 4 Engine Oil Pressure Low Voltage / Open 1 1 P 100 4 128/143 4 Engine Oil Pressure High Voltage 1 1 P 100 3 128/143 9 Barometric
Gerry Kaelin, FilterSense, USA, describes the ways in which optimising toward compliance with environmental regulations can reduce baghouse
Gerry Kaelin, FilterSense, USA, describes the ways in which optimising toward compliance with environmental regulations can reduce baghouse maintenance and operational expenses. Making Sense Introduction
Vetting Smart Instruments for the Nuclear Industry
TS Lockhart, Director of Engineering Moore Industries-International, Inc. Vetting Smart Instruments for the Nuclear Industry Moore Industries-International, Inc. is a world leader in the design and manufacture
Safety manual for Fisherr ED,ES,ET,EZ, HP, or HPA Valves with 657 / 667 Actuator
Instruction Manual Supplement ED, ES, ET, EZ, HP, HPA Valves with 657/667 Actuator Safety manual for Fisherr ED,ES,ET,EZ, HP, or HPA Valves with 657 / 667 Actuator Purpose This safety manual provides information
SAFETY MANUAL SIL RELAY MODULE
PROCESS AUTOMATION SAFETY MANUAL SIL RELAY MODULE KFD0-RSH-1.4S.PS2 ISO9001 3 With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery
S a f e t y & s e c u r i t y a l i g n m e n t b e n e f i t s f o r h i g h e r o p e r a t i o n a l i n t e g r i t y R A H U L G U P TA
Unraveling the Jargon Between Functional Safety & Cyber Security Related to Industrial Control Systems ( ICS) S a f e t y & s e c u r i t y a l i g n m e n t b e n e f i t s f o r h i g h e r o p e r a
New Generation of Deepwater BOP Stacks. Dominique Allegre CAMERON Paris, October 23rd 2013
New Generation of Deepwater BOP Stacks Dominique Allegre CAMERON Paris, October 23rd 2013 Agenda: Evolution of Standards API Standard 53 RP 17W New Equipment & Technology Developments: Shearing Technology
MOBILE DC POWER SYSTEMS FOR SUBSTATION APPLICATIONS
MOBILE DC POWER SYSTEMS FOR SUBSTATION APPLICATIONS Gary P. Guagliardi Director Sales & Marketing HindlePower, Inc. Easton, PA Introduction This paper explores the use of mobile DC power systems for three
SELECTION, APPLICATION AND MAINTENANCE
DIESEL PROTECTION SYSTEMS Automatic Diesel Engine Shut Down System for Safe Area Applications SELECTION, APPLICATION AND MAINTENANCE Series 300 Series 310 SYSTEM DESCRIPTION Suitable for attended engine
IEC 61508 Functional Safety Assessment. Project: K-TEK Corporation AT100, AT100S, AT200 Magnetostrictive Level Transmitter.
61508 SIL 3 CAPABLE IEC 61508 Functional Safety Assessment Project: K-TEK Corporation AT100, AT100S, AT200 Magnetostrictive Level Transmitter Customer: K-TEK Corporation Prairieville, LA USA Contract No.:
Practical Implementation of Safety Management Systems at Unregulated Upstream Oil & Gas Facilities
Practical Implementation of Safety Management Systems at Unregulated Upstream Oil & Gas Facilities Kristin D. Norton, PE CFSE Risk Management Professionals, Inc. 300 Goddard, Suite 200 Irvine, California
Operations and Maintenance Procedures for Natural Gas Systems
Operations and Maintenance Procedures for Natural Gas Systems Contact Information John West Transportation Specialist U.S. Department of Transportation PHMSA Office of Training and Qualifications Office
The New Technology Frontier: Moving Oil and Gas Production to the Seabed. By: Allen Rentcome and Rick McLin, Rockwell Automation
The New Technology Frontier: Moving Oil and Gas Production to the Seabed By: Allen Rentcome and Rick McLin, Rockwell Automation The New Technology Frontier: Moving Oil and Gas Production to the Seabed
Integrated Fire and Gas Solution - Improves Plant Safety and Business Performance
Integrated Fire and Gas Solution - Improves Plant Safety and Business Performance Integrated Fire and Gas Solution - Improves Plant Safety and Business Performance 1 Table of Contents Table of Figures...1
Natural Gas Well Automation using Kingfisher RTU Products
Natural Gas Well Automation using Kingfisher RTU Products Introduction Semaphore s Kingfisher RTU products have been applied to well site installations throughout the world. The product family includes
Design Options for Overfill Prevention for Aboveground Storage Tanks
INFRASTRUCTURE MINING & METALS NUCLEAR, SECURITY & ENVIRONMENTAL OIL, GAS & CHEMICALS Design Options for Overfill Prevention for Aboveground Storage Tanks About Bechtel Bechtel is among the most respected
Implementing a Reliable Furnace Monitoring System
Category: Manufacturing Implementing a Reliable Furnace Monitoring System Products Used: RT Series PXI (PXI 1002 And PXI 8156B) LabVIEW Real-Time by V. Arunachalam Sr. Project Engineer Anand Chinnaswamy
THE GAS UTILITIES S AND THE JAPAN GAS ASSOCIATION S EFFORTS TO IMPROVE SAFETY
THE GAS UTILITIES S AND THE JAPAN GAS ASSOCIATION S EFFORTS TO IMPROVE SAFETY Kunihiro Hara Assistant Manager of Safety Technology Sec.,Gas Technology Dept., The Japan Gas Association 1. City Gas Safety
FEDERAL GOVERNMENT OVERSIGHT OF PIPELINE SAFETY
Operational Safety INTRODUCTION The Millennium Pipeline Company (Millennium) is proud of the key role it plays in New York s energy infrastructure. The Millennium Pipeline is a vital link in a system that
Rigorous Qualification and Development Program
FMC Subsea High Capacity 20K Wellhead System Overview 03/20/2013 UWD HC-20 Subsea Wellhead System Rigorous Qualification and Development Program 2 1 Qualification program Qualification testing is performed
TÜV Rheinland Functional Safety Program Functional Safety Engineer Certification
TÜV Rheinland Functional Safety Program Functional Safety Engineer Certification The TÜV Rheinland Functional Safety Program is a unique opportunity to provide certified evidence of competency in functional
Production Measurement & Allocation CPMA 20.1. Robbie Lansangan, Ph.D. Measurement Eng. Technical Authority BP Upstream Global Projects
Production easurement & Allocation CPA 20.1 Robbie Lansangan, Ph.D. easurement Eng. Technical Authority BP Upstream Global Projects Presentation Outline What is CPA and where does it fit in the API COP?
Mitigating safety risk and maintaining operational reliability
Mitigating safety risk and maintaining operational reliability Date 03/29/2010 Assessment and cost-effective reduction of process risks are critical to protecting the safety of employees and the public,
Regulations and Recommended Practices. Introduction. American Petroleum Institute Recommended Practices 2350
Meeting Spill Prevention Regulations using RF Admittance and Ultrasonic Level Measurement Technologies Martin Bahner Marketing Manager Drexelbrook Engineering Co. 205 Keith Valley Rd. Horsham, PA 19044
Is your current safety system compliant to today's safety standard?
Is your current safety system compliant to today's safety standard? Abstract It is estimated that about 66% of the Programmable Electronic Systems (PES) running in the process industry were installed before
Training for Operations and Maintenance
Oil and Gas Training and Competency Development Training for Operations and Maintenance Developing technical skills and building practical experience for E&P teams and professionals Training that meets
Introduction to Subsea Production System
Introduction to Subsea Production System 04 Xmas Tree Systems Bjørn Søgård Xmas Tree Systems This module will cover: Main codes for XT equipment XT Principles and functions Typical schematic Main types
,g) rrrs {fd fi. f il'ltdä. Failure Modes, Effects and Diagnostic Analysis. ABB Automation Products GmbH Alzenau Germany
' I rrrs {fd fi 1;;,g) -.- f il'ltdä Failure Modes, Effects and Diagnostic Analysis Project: Temperature transmitters TSP***, TT*200-*H and TT*3*0-*H with 4..20 ma output Customer: ABB Automation Products
Model: 400E-2M. Bermad Electrically Controlled Deluge Valve with Easy Lock Manual Reset. Installation Operation Maintenance. Application Engineering
Model: 400E-2M Bermad Electrically Controlled Deluge Valve with Easy Lock Manual Reset Installation Operation Maintenance Application Engineering BERMAD 1. Safety First BERMAD believes that the safety
White Paper. Chemical dosing and blending - the role of precision actuators
White Paper Chemical dosing and blending - the role of precision actuators Chemical dosing and blending - the role of precision actuators White Paper 16 th August 2014 Chemical dosing and blending - the
DECEMBER 21, 2012. Sincerely, Jeffrey D. Wiese Associate Administrator for Pipeline Safety
DECEMBER 21, 2012 Mr. Rolf A. Gafvert President Texas Gas Transmission, LLC 3800 Frederica Street Owensboro, KY 42301 Re: CPF No. 4-2012-1015 Dear Mr. Gafvert: Enclosed please find the Final Order issued
Subsea School The training program
Subsea School The training program Table of Contents Welcome to the FMC Subsea School... 3 Training Schedules and Participation... 4 SS Subsea Technology Introduction... 5 MPS - Subsea Structures... 6
JOURNAL OF INFORMATION, KNOWLEDGE AND RESEARCH IN MECHANICAL ENGINEERING
Automated Spares and Inventory Management System For Upstream Oil and Gas Producing Facilities Using RFID Based Item Tracking Integrated With Enterprise Resource Planning Through Centralized Onshore Sourcing
ABB PSPS Erich Steinmann; Generator control-2013
ABB PSPS Erich Steinmann; Generator control-2013 GENERATOR CONTROL THE MODULAR SOLUTION FOR GENERATORS To make sure that power is efficiently converted into electric energy, it is necessary to supervise
PLC Based Liquid Filling and Mixing
PLC Based Liquid Filling and Mixing 1 Mihir Panchal, 2 Aashish Panaskar. 3 Prof. Lalit Kumar KJ College of Engineering and Management Research, Pune, India Abstract: The objective of this paper is to design,
SELECTION, APPLICATION & MAINTENANCE
DIESEL PROTECTION SYSTEMS TPZ Engine Air Intake Shut Down Valves (Combined Automatic Overspeed and Air Pressure Operated Shut Down Bendix Types) SELECTION, APPLICATION & MAINTENANCE Valve Numbers TPZ-101
RECOMMENDED GUIDELINES FOR THE APPLICATION OF IEC 61508 AND IEC 61511 IN THE PETROLEUM ACTIVITIES ON THE NORWEGIAN CONTINENTAL SHELF
RECOMMENDED GUIDELINES FOR THE APPLICATION OF IEC 61508 AND IEC 61511 IN THE PETROLEUM ACTIVITIES ON THE NORWEGIAN CONTINENTAL SHELF No.: 070 Date effective: 1.02.2001 Revision no.: 01 Date revised: NA