Regulator Flow Curves For Bulk Gas Systems, Cylinder Gas Cabinets and Gas Distribution Systems Report # Rev 4

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "Regulator Flow Curves For Bulk Gas Systems, Cylinder Gas Cabinets and Gas Distribution Systems Report # 30008300 Rev 4"

Transcription

1 Regulator Flow Curves For Bulk Gas Systems, Cylinder Gas Cabinets and Gas Distribution Systems Report # 383 Rev 4 June 5, 213 Scope: This document is a reference guide to help customers determine an appropriate AP Tech pressure regulator model based on system flow requirements. It is an array of regulator flow curves for the most popular AP Tech pressure regulators used in bulk gas systems, cylinder gas cabinets and gas distribution systems. For information and specifications related to the specific model regulator, please refer to the catalog data sheet. Advanced Pressure Technology 687 Technology Way Napa, CA Telephone:

2 General Recommendations Regulator Series AP11 (AZ11, AK11) AP11 HF (AZ11 HF, AK11 HF) AP111 (AP111, AZ111) AP111 HF (AP111 HF) AP121 (AZ121, AK121) AP121 HF (AZ121 HF, AK121 HF) AP121 FC (AZ121 FC, AK121 FC) AP142 TA (AZ142 TA) AP141T (AK141T) AP151 (AK151) Maximum Source Pressure (psig) Maximum Outlet Pressure (psig) Flow Coefficient, Cv Recommended Maximum Flow (slm nitrogen) 3, , , , , , , , AP191 HF 3, Page 2 of 8

3 General Recommendations AP91 1, , AP93 1, , AP , Page 3 of 8

4 General Notes 1. AZ and AK series regulators have the same flow performance as their AP counterpart (e.g. for an AK11 regulator refer to the AP11 flow curves and for an AZ121 regulator refer to the AP121 flow curves). 2. The recommended maximum flow might not be achievable depending on the inlet pressure. Please refer to specific flow curve conditions. 3. For applications where the inlet pressure is above 6 psig, use the 6 psig inlet pressure flow curve as the change in flow performance due to higher inlet pressure will not significantly change the shape of the flow curve. 4. Most regulator series are available with higher outlet pressure ranges although the source pressure may be lowered for certain models. Refer to the data sheet for the specific regulator or consult the factory to determine availability and specifications. 5. Some regulators have options that can affect the maximum source pressure, maximum outlet pressure, and recommended maximum flow rate. 6. In general, it is recommended that the regulator that meets the flow conditions and has the smallest flow coefficient be selected. Typically, this regulator would have better performance in other characteristics and cost less. Page 4 of 8

5 AP11 Flow Curve Index Series Inlet Pressure (psig) Outlet Pressures (psig) Connection Size Flow Curve Number 6 9, 5, 3 1/4 inch AP , 5, 3 1/4 inch AP11-2 AP11 AZ11 AK , 5, 3 1/4 inch AP , 5, 3 1/4 inch AP /4 inch AP11-5 Page 5 of 8

6 1 AP11S 2PW FV4 FV4 Flow Curve at 6 psig Inlet Pressure Page 6 of 8

7 1 AP11S 2PW FV4 FV4 Flow Curve at 3 psig Inlet Pressure Page 7 of 8

8 1 AP11S 2PW FV4 FV4 Flow Curve at 15 psig Inlet Pressure Page 8 of 8

9 8 AP11S 2PW FV4 FV4 Flow Curve at 1 psig Inlet Pressure Page 9 of 8

10 4 AP11S 2PW FV4 FV4 Flow Curve at 5 psig Inlet Pressure Page 1 of 8

11 AP11 HF Flow Curve Index Series Inlet Pressure (psig) Outlet Pressures (psig) Connection Size Flow Curve Number 6 9, 5, 3 1/4 inch AP11HF-1 3 9, 5, 3 1/4 inch AP11HF-2 AP11 HF AZ11 HF AK11 HF 15 9, 5, 3 1/4 inch AP11HF , 5, 3 1/4 inch AP11HF /4 inch AP11HF-5 Page 11 of 8

12 1 AP11S 2PW FV4 FV4 HF Flow Curve at 6 psig Inlet Pressure Page 12 of 8

13 1 AP11S 2PW FV4 FV4 HF Flow Curve at 3 psig Inlet Pressure Page 13 of 8

14 1 AP11S 2PW FV4 FV4 HF Flow Curve at 15 psig Inlet Pressure Page 14 of 8

15 8 AP11S 2PW FV4 FV4 HF Flow Curve at 1 psig Inlet Pressure Page 15 of 8

16 35 AP11S 2PW FV4 FV4 HF Flow Curve at 5 psig Inlet Pressure Page 16 of 8

17 AP111 Flow Curve Index Series Inlet Pressure (psig) Outlet Pressures (in Hg) Connection Size Flow Curve Number AP111 AZ , 15, 21 1/4 inch AP111_c AP111 HF 2 ¼ inch AP111HF_a Page 17 of 8

18 AP 111S FV4 FV4 Inlet Pressure = 1.45 psig (.1 Mpa) OUTLET PRESSURE (in.hg Vacuum) OUTLET PRESSURE (mm Hg Absolute) Flow Rate - SLPM Page 18 of 8

19 AP 111S HF FV4 FV4 Inlet Pressure 2 psig (.1 Mpa) OUTLET PRESSURE (in.hg Vacuum) OUTLET PRESSURE (mm Hg Absolute) Flow Rate - SLPM Page 19 of 8

20 AP121 Flow Curve Index Series Inlet Pressure (psig) Outlet Pressures (psig) Connection Size Flow Curve Number AP121 AZ121 AK , 5, 3 3 9, 5, , 5, , 5, /2 inch AP /4 inch AP /2 inch AP /4 inch AP /2 inch AP /4 inch AP /2 inch AP /4 inch AP /2 inch AP /4 inch AP121-1 Page 2 of 8

21 1 AP121S 2PW FV8 FV8 Flow Curve at 6 psig Inlet Pressure Page 21 of 8

22 1 AP121S 2PW FV12 FV12 Flow Curve at 6 psig Inlet Pressure Page 22 of 8

23 1 AP121S 2PW FV8 FV8 Flow Curve at 3 psig Inlet Pressure Page 23 of 8

24 1 AP121S 2PW FV12 FV12 Flow Curve at 3 psig Inlet Pressure Page 24 of 8

25 1 AP121S 2PW FV8 FV8 Flow Curve at 15 psig Inlet Pressure Page 25 of 8

26 1 AP121S 2PW FV12 FV12 Flow Curve at 15 psig Inlet Pressure Page 26 of 8

27 8 AP121S 2PW FV8 FV8 Flow Curve at 1 psig Inlet Pressure Page 27 of 8

28 8 AP121S 2PW FV12 FV12 Flow Curve at 1 psig Inlet Pressure Page 28 of 8

29 4 AP121S 2PW FV8 FV8 Flow Curve at 5 psig Inlet Pressure Page 29 of 8

30 4 AP121S 2PW FV12 FV12 Flow Curve at 5 psig Inlet Pressure Page 3 of 8

31 AP121 HF Flow Curve Index Series Inlet Pressure (psig) Outlet Pressures (psig) Connection Size Flow Curve Number AP121 HF AZ121 HF AK121 HF 6 9, 5, 3 3 9, 5, , 5, , 5, /2 inch AP121HF-1 3/4 inch AP121HF-2 1/2 inch AP121HF-3 3/4 inch AP121HF-4 1/2 inch AP121HF-5 3/4 inch AP121HF-6 1/2 inch AP121HF-7 3/4 inch AP121HF-8 1/2 inch AP121HF-9 3/4 inch AP121HF-1 Page 31 of 8

32 1 AP121S 2PW FV8 FV8 HF Flow Curve at 6 psig Inlet Pressure Page 32 of 8

33 1 AP121S 2PW FV12 FV12 HF Flow Curve at 6 psig Inlet Pressure Page 33 of 8

34 1 AP121S 2PW FV8 FV8 HF Flow Curve at 3 psig Inlet Pressure Page 34 of 8

35 1 AP121S 2PW FV12 FV12 HF Flow Curve at 3 psig Inlet Pressure Page 35 of 8

36 1 AP121S 2PW FV8 FV8 HF Flow Curve at 15 psig Inlet Pressure Page 36 of 8

37 1 AP121S 2PW FV12 FV12 HF Flow Curve at 15 psig Inlet Pressure Page 37 of 8

38 8 AP121S 2PW FV8 FV8 HF Flow Curve at 1 psig Inlet Pressure Page 38 of 8

39 8 AP121S 2PW FV12 FV12 HF Flow Curve at 1 psig Inlet Pressure Page 39 of 8

40 4 AP121S 2PW FV8 FV8 HF Flow Curve at 5 psig Inlet Pressure Page 4 of 8

41 4 AP121S 2PW FV12 FV12 HF Flow Curve at 5 psig Inlet Pressure Page 41 of 8

42 AP121 FC Flow Curve Index Series Inlet Pressure (psig) Outlet Pressures (psig) Connection Size Flow Curve Number AP121 FC AZ121 FC AK121 FC 15 75, 5, , 5, /2 inch AP121FC-1 3/4 inch AP121FC-2 1/2 inch AP121FC-3 3/4 inch AP121FC-4 1/2 inch AP121FC-5 3/4 inch AP121FC-6 Page 42 of 8

43 8 AP121S 2PW FV8 FV8 FC Flow Curve at 15 psig Inlet Pressure Page 43 of 8

44 8 AP121S 2PW FV12 FV12 FC Flow Curve at 15 psig Inlet Pressure Page 44 of 8

45 8 AP121S 2PW FV8 FV8 FC Flow Curve at 1 psig Inlet Pressure Page 45 of 8

46 8 AP121S 2PW FV12 FV12 FC Flow Curve at 1 psig Inlet Pressure Page 46 of 8

47 4 AP121S 2PW FV8 FV8 FC Flow Curve at 5 psig Inlet Pressure Page 47 of 8

48 4 AP121S 2PW FV12 FV12 FC Flow Curve at 5 psig Inlet Pressure Page 48 of 8

49 AP142TA Flow Curve Index Series Inlet Pressure (psig) Outlet Pressures Connection Size Flow Curve Number, 1, 18 in Hg (vac) 1/4 inch AP142TA AP142TA AK142TA in Hg (vac) 1/4 inch AP142TA_a 1 in Hg (vac) 1/4 inch AP142TA_e 3 1 psig 1/4 inch AP142TA_c Page 49 of 8

50 AP 142 TSA 2PW FV4 FV4 Inlet Pressure = psig (76 mm Hg) Outlet Pressure (in. Hg Vacuum) Outlet Pressure (mm Hg Absolute) Flow Rate (slpm Nitrogen) Page 5 of 8

51 AP 142 TSA 2PW FV4 FV4 Inlet Pressure - 2psig (76) 5 (66) (56) OUTLET PRESSURE (in.hg of Vacuum) (46) (36) (26) OUTLET PRESSURE (mm Hg Absolute) 25 (16) (6) Flow Rate in SLPM of Nitrogen Page 51 of 8

52 AP 142 TSA 2PW FV4 FV4 Inlet Pressure - 1 psig (76) 5 (66) (56) 1 OUTLET PRESSURE (in.hg of Vacuum) 15 2 (46) (36) (26) OUTLET PRESSURE (mm Hg Absolute) 25 (16) (6) Flow Rate in SLPM of Nitrogen Page 52 of 8

53 2 AP 142 TSA 2PW FV4 FV4 Inlet Pressure - 3 psig (.2 MPa) Outlet Pressure, MPa Flow Rate, slpm nitrogen. Page 53 of 8

54 AP141T Flow Curve Index Series Inlet Pressure (psig) Outlet Pressures (psig) Connection Size Flow Curve Number AP141T AK141T 6 9, 5, 3 3 9, 5, , 5, /4 inch AP141T-1 1/2 inch AP141T-2 1/4 inch AP141T-3 1/2 inch AP141T-4 1/4 inch AP141T-5 1/2 inch AP141T-6 1/4 inch AP141T-7 1/2 inch AP141T-8 Page 54 of 8

55 1 AP141TS 2PW FV4 FV4 Flow Curve at 6 psig Inlet Pressure Page 55 of 8

56 1 AP141TS 2PW FV8 FV8 Flow Curve at 6 psig Inlet Pressure Page 56 of 8

57 1 AP141TS 2PW FV4 FV4 Flow Curve at 3 psig Inlet Pressure Page 57 of 8

58 1 AP141TS 2PW FV8 FV8 Flow Curve at 3 psig Inlet Pressure Page 58 of 8

59 8 AP141TS 2PW FV4 FV4 Flow Curve at 1 psig Inlet Pressure Page 59 of 8

60 8 AP141TS 2PW FV8 FV8 Flow Curve at 1 psig Inlet Pressure Page 6 of 8

61 4 AP141TS 2PW FV4 FV4 Flow Curve at 5 psig Inlet Pressure Page 61 of 8

62 4 AP141TS 2PW FV8 FV8 Flow Curve at 5 psig Inlet Pressure Page 62 of 8

63 AP151 Flow Curve Index Series Inlet Pressure (psig) Outlet Pressures (psig) Connection Size Flow Curve Number 6 9, 5, 3 1/4 inch AP , 5, 3 1/4 inch AP151-2 AP151 AK , 5, 3 1/4 inch AP , 5, 3 1/4 inch AP /4 inch AP151-5 Page 63 of 8

64 1 AP151S 2PW FV4 FV4 Flow Curve at 6 psig Inlet Pressure Page 64 of 8

65 1 AP151S 2PW FV4 FV4 Flow Curve at 3 psig Inlet Pressure Page 65 of 8

66 1 AP151S 2PW FV4 FV4 Flow Curve at 15 psig Inlet Pressure Page 66 of 8

67 8 AP151S 2PW FV4 FV4 Flow Curve at 1 psig Inlet Pressure Page 67 of 8

68 4 AP151S 2PW FV4 FV4 Flow Curve at 5 psig Inlet Pressure Page 68 of 8

69 AP191 HF Flow Curve Index Series Inlet Pressure (psig) Outlet Pressures (psig) Connection Size Flow Curve Number AP191 HF 6 9, 5, 3 3 9, 5, , 5, 3 1/4 inch AP191HF-1 1/2 inch AP191HF-2 1/4 inch AP191HF-3 1/2 inch AP191HF-4 1/4 inch AP191HF-5 1/2 inch AP191HF-6 Page 69 of 8

70 1 AP191S 2PW FV4 FV4 HF Flow Curve at 6 psig Inlet Pressure Page 7 of 8

71 1 AP191S 2PW FV8 FV8 HF Flow Curve at 6 psig Inlet Pressure Page 71 of 8

72 1 AP191S 2PW FV4 FV4 HF Flow Curve at 3 psig Inlet Pressure Page 72 of 8

73 1 AP191S 2PW FV8 FV8 HF Flow Curve at 3 psig Inlet Pressure Page 73 of 8

74 8 AP191S 2PW FV4 FV4 HF Flow Curve at 1 psig Inlet Pressure Page 74 of 8

75 8 AP191S 2PW FV8 FV8 HF Flow Curve at 1 psig Inlet Pressure Page 75 of 8

76 AP9 Flow Curve Index Series Inlet Pressure (psig) Outlet Pressures (psig) Connection Size Flow Curve Number AP91 6 9, 5, 3 3 9, 5, , 5, 3 3/4 inch AP inch AP91-2 3/4 inch AP inch AP91-4 3/4 inch AP inch AP91-6 AP , 5, 3 3/4 inch AP inch AP93-2 3/4 inch AP inch AP911-2 AP , 5, , 5, 3 3/4 inch AP inch AP /4 inch AP inch AP911-6 Page 76 of 8

77 1 AP91S 2PW FV12 FV12 Flow Curve at 6 psig Inlet Pressure Page 77 of 8

78 1 AP91S 2PW FV16 FV16 Flow Curve at 6 psig Inlet Pressure Page 78 of 8

79 1 AP91S 2PW FV12 FV12 Flow Curve at 3 psig Inlet Pressure Page 79 of 8

80 1 AP91S 2PW FV16 FV16 Flow Curve at 3 psig Inlet Pressure Page 8 of 8

81 8 AP91S 2PW FV12 FV12 Flow Curve at 1 psig Inlet Pressure Page 81 of 8

82 8 AP91S 2PW FV16 FV16 Flow Curve at 1 psig Inlet Pressure Page 82 of 8

83 3 AP93S 2PW FV12 FV12 Flow Curve at 6 psig Inlet Pressure Page 83 of 8

84 3 AP93S 2PW FV16 FV16 Flow Curve at 6 psig Inlet Pressure Page 84 of 8

85 1 AP911S 2PW FV12 FV12 Flow Curve at 3 psig Inlet Pressure Page 85 of 8

86 1 AP911S 2PW FV16 FV16 Flow Curve at 3 psig Inlet Pressure Page 86 of 8

87 1 AP911S 2PW FV12 FV12 Flow Curve at 15 psig Inlet Pressure Page 87 of 8

88 1 AP911S 2PW FV16 FV16 Flow Curve at 15 psig Inlet Pressure Page 88 of 8

89 8 AP911S 2PW FV12 FV12 Flow Curve at 1 psig Inlet Pressure Page 89 of 8

90 8 AP911S 2PW FV16 FV16 Flow Curve at 1 psig Inlet Pressure Page 9 of 8

PRESSURE REGULATOR AND VALVE SELECTION GUIDE

PRESSURE REGULATOR AND VALVE SELECTION GUIDE PRESSURE REGULATOR AND VALVE SELECTION GUIDE Technical Bulletin #8F Scope: This document is a reference guide to help customers determine an appropriate AP Tech valve and regulator to be used in process

More information

Check Valve. Series AP64. How to Order. Specifications. Wetted Parts Material

Check Valve. Series AP64. How to Order. Specifications. Wetted Parts Material Check Valve Series AP4 Simple design with free of springs and poppets Reseals with minimal back pressure Low cracking pressure AP4 S How to Order (Inlet) (Outlet) Material Code Body material S L SS secondary

More information

Regulator Performance Definitions

Regulator Performance Definitions Technical data regulator technical data Regulator Performance Definitions What information can be determined from a flow curve? The following sketch explains how to interpret the flow curves presented

More information

ball valves Flomite 71 Series 2-way Integral Panel Mount Ball Valves

ball valves Flomite 71 Series 2-way Integral Panel Mount Ball Valves 2-way Integral Panel Mount Ball Valves Used for quick on-off service with a visual indication of flow, HOKE s 2-way ball valves offer orifice sizes up to 0.25 (6.4mm). Flomite valves feature a floating

More information

Test Report # Rev 2. Nitrous Oxide Compatibility Test

Test Report # Rev 2. Nitrous Oxide Compatibility Test Test Report # 30016497 Rev 2 Nitrous Oxide Compatibility Test Scope: This test report contains chemical compatibility test data of nitrous oxide with PCTFE (Daikin Neoflon M-400H), polyimide (Dupont Vespel

More information

Recharge Procedure for Telemark TVP-2000 and TVP-3500

Recharge Procedure for Telemark TVP-2000 and TVP-3500 Recharge Procedure for Telemark TVP-2000 and TVP-3500 Required items: 1.) Refrigeration service manifold. 2.) Charge recovery system. 3.) Dry nitrogen gas. If a high pressure cylinder is used, a pressure

More information

G234X-55 Conventional Gas Boiler

G234X-55 Conventional Gas Boiler Engineering Submittal Sheet Boiler Overview C US Engineering Specifications There shall be provided and installed a quantity of Buderus G234X-55 fl oor standing hot water boiler(s), suitable with natural

More information

A practical guide to restrictive flow orifices

A practical guide to restrictive flow orifices Safetygram 46 A practical guide to restrictive flow orifices Restrictive flow orifices (RFOs) installed in cylinder valve outlets provide a significant safety benefit for users of hazardous gases, especially

More information

Element D Services Plumbing

Element D Services Plumbing Laboratory Vacuum and Gas PART 1 - GENERAL 1.01 OVERVIEW A. This section addresses laboratory vacuum, compressed air, gaseous nitrogen, and carbon dioxide systems within and to five feet beyond building

More information

CITY OF LOS ANGELES CALIFORNIA

CITY OF LOS ANGELES CALIFORNIA BOARD OF BUILDING AND SAFETY COMMISSIONERS MARSHA L. BROWN PRESIDENT PEDRO BIRBA VICE-PRESIDENT VAN AMBATIELOS HELENA JUBANY ELENORE A. WILLIAMS November 14, 2007 CITY OF LOS ANGELES CALIFORNIA ANTONIO

More information

Engineering Information For PDC Butterfly Valves

Engineering Information For PDC Butterfly Valves Engineering Information For PDC Butterfly Valves Valve Sizing: Cv sizing is the most widely used method for valve sizing, today. By using the Cv method, the proper valve size can be accurately determined

More information

Flow Curves and Calculations Technical Information

Flow Curves and Calculations Technical Information Flow Curves and Calculations Technical Information debul2007x012 Flow Curves Tescom flow charts are the graphic representation of test results which show the change in outlet pressure (P 2 ) with a varying

More information

AUTOMATIC CHANGEOVER MANIFOLD Series 915

AUTOMATIC CHANGEOVER MANIFOLD Series 915 AUTOMATIC CHANGEOVER MANIFOLD Series 915 FEATURES Fully automatic, simple, hassle-free operation No variance in delivery pressure Designed for ultra high purity gas service Built-in audio and visual alarm

More information

Extending Orifice Flow Data

Extending Orifice Flow Data 46 Extending Flow Data EXTRAPOLATION 1. Specific Gravity Other Gases To convert air flow from chart to another gas flow. Flow (gas) = Flow (air) / S.G. (gas) To obtain flow rate for helium when air flow

More information

Model 111 Mass Flow Instruments

Model 111 Mass Flow Instruments 111 Mass Instruments Porter Mass products reflect over four decades of experience in the design and manufacture of precision instruments for the measurement and control of gas flow. They incorporate design

More information

OPERATION AND MAINTENANCE MANUAL

OPERATION AND MAINTENANCE MANUAL ZERO-AIR GENERATOR OPERATION AND MAINTENANCE MANUAL P.O. Box 2105, 8 Executive Drive, Toms River, N.J. 08754 Phone: (732) 244-0010 / (800) 337-3762 Fax: (732) 244-8140 Form #240 Rev 11/98 Table of Contents

More information

Element D Services Plumbing

Element D Services Plumbing Medical Vacuum and Gas PART 1 - GENERAL 1.01 OVERVIEW A. This section addresses medical vacuum, waste anesthetic gas disposal, compressed air, oxygen, nitrous oxide, nitrogen and carbon dioxide systems.

More information

Vacuum Control. Vacuum Applications. Vacuum Regulators. Vacuum Breakers (Relief Valves) Vacuum Control Devices. Vacuum Terminology

Vacuum Control. Vacuum Applications. Vacuum Regulators. Vacuum Breakers (Relief Valves) Vacuum Control Devices. Vacuum Terminology Vacuum Applications Vacuum regulators and breakers are widely used in process plants. Conventional regulators and relief valves might be suitable for service if applied correctly. This section provides

More information

Laminar Flow Elements

Laminar Flow Elements Laminar Flow Elements Meriam Laminar Flow Elements (LFEs) are excellent for measuring low gas flow rates from 0.2 SCCM up to 2250 SCFM. They are inherently accurate and repeatable and are calibrated traceable

More information

Regulator Performance Data

Regulator Performance Data Regulator Performance Data The regulator flow data is provided to assist in determining the proper regulator for the required application. The data is given for reference purpose only. If additional information

More information

KNC Model 3666 Automatic Pressure Calibration System

KNC Model 3666 Automatic Pressure Calibration System KNC Model 3666 Automatic Pressure Calibration System Product Description The Model 3666 Automatic Pressure Calibration (APC) System by King Nutronics Corporation is a portable secondary standards laboratory

More information

Porter Pressure Regulators

Porter Pressure Regulators Porter Pressure Regulators Porter Precision Pressure Regulators Engineered to Excel in Critical Applications The Porter Instrument Division of Parker Hannifin Corporation is a leading manufacturer of specialized

More information

Meriam Instrument LFE Data Sheet

Meriam Instrument LFE Data Sheet 1. AIR FLOW IN SCFM AT STANDARD CONDITIONS OF 29.92 AND 70 F. SCFM = Standard cubic feet per minute. ACFM = Actual cubic feet per minute CFM = Cubic feet per minute. When the flowing gas is air and the

More information

THE UNITED KINGDOM VEHICLE APPROVAL AUTHORITY

THE UNITED KINGDOM VEHICLE APPROVAL AUTHORITY THE UNITED KINGDOM VEHICLE APPROVAL AUTHORITY COMMUNICATION CONCERNING THE APPROVAL EXTENDED OF A TYPE OF CNG COMPONENT, PURSUANT TO REGULATION NO 110 E11 Approval No: 110R-000004 Extension No: 04 1. CNG

More information

OEM-EP Pressure Controllers

OEM-EP Pressure Controllers Pressure Controllers Typical Applications Carrier Gas Pressure Control Air over Liquid Control Mass Spectrometer Process Gas Supply Pressure Control Miniature ler The Miniature ler converts a variable

More information

Compact, High-Flow Gas Regulators

Compact, High-Flow Gas Regulators www.swagelok.com Compact, High-Flow Gas Regulators HF Series Precise pressure control Tamper-free design High-purity design Preset and adjustable dome-loaded models 2 Compact, High-Flow Gas Regulators

More information

ENDURANCE Conductivity Sensors

ENDURANCE Conductivity Sensors Instruction Manual 400 and 400VP LIQ_MAN_ABR_400_400VP December 2013 ENDURANCE Conductivity Sensors For additional information, please refer visit our website at www.rosemountanalytical.com. CAUTION Sensor/Process

More information

SPECIFICATION SHEET : WH5-120-L

SPECIFICATION SHEET : WH5-120-L SPECIFICATION SHEET : WH5120L *F3 2 T8 3 1 0 6 0.9 3 1.2 6 1.1 9 *F3 2 T8 4 1 2 7 1.1 3 1.1 1 0.8 7 F5 4 T5 H O 2 1 0 8 0.9 6 1.0 7 0.9 9 *F5 8 T8 2 1 1 0 0.9 7 1.0 8 0.9 8 *F4 0 T1 0 2 1 0 1 0.9 0 1.3

More information

EVR Series Precision Vacuum Regulating Valves

EVR Series Precision Vacuum Regulating Valves EVR Series Precision Vacuum Regulating Valves Electronic Control Automated Vacuum Control 1 EVR-GSD8A vacuum regulator with electronic set-point regulator Manual Control Manual Vacuum Control 1/2 EVR-GSD4P

More information

excess flow control XVH Series Excess Flow Valve

excess flow control XVH Series Excess Flow Valve Excess Flow Valve Circle Seal Controls 2301 Wardlow Circle Corona, CA 92880 Phone (951) 270-6200 Fax (951) 270-6201 www.circlesealcontrols.com excess flow control Excess Flow Valves XVH Series Excess Flow

More information

Side-Trak 830/840. Process Gas Mass Flow Meters and Controllers. www.sierrainstruments.com

Side-Trak 830/840. Process Gas Mass Flow Meters and Controllers. www.sierrainstruments.com Process Gas Mass Flow Meters and Controllers Features n Direct monitoring of mass flow eliminates need for ancillary pressure and temperature sensing n Patented straight sensor tube with access ports permits

More information

1. A belt pulley is 3 ft. in diameter and rotates at 250 rpm. The belt which is 5 ins. wide makes an angle of contact of 190 over the pulley.

1. A belt pulley is 3 ft. in diameter and rotates at 250 rpm. The belt which is 5 ins. wide makes an angle of contact of 190 over the pulley. Sample Questions REVISED FIRST CLASS PARTS A1, A2, AND A3 (NOTE: these questions are intended as representations of the style of questions that may appear on examinations. They are not intended as study

More information

RUSKA PRODUCTS - PRICE LIST

RUSKA PRODUCTS - PRICE LIST RUSKA PRODUCTS - PRICE LIST Effective Date: This price list is effective January 1, 2010 and supersedes all previous price lists for the items contained herein. NVLAP An optional ISO 17025 accredited calibration

More information

3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223

3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223 3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223 HERION S HIGH PERFORMANCE POPPET VALVES For those applications requiring high Cv, fast response times, large

More information

Nitrogen Generators for LCMS

Nitrogen Generators for LCMS Specification manual Nitrogen Generators for LCMS Model N2-MISTRAL-0-60L schmidlin-dbs AG CH-6345 Neuheim Tel. +41 (0)41 757 61 61 Fax +41 (0)41 757 61 69 NOTICE: This manual is intended to provide technical

More information

PORTER MASS FLOW MEASUREMENT AND CONTROL SYSTEMS

PORTER MASS FLOW MEASUREMENT AND CONTROL SYSTEMS PORTER MASS MEASUREMENT AND CONTROL SYSTEMS PORTER: THE STANDARD OF EXCELLENCE IN MASS Porter Mass Flow products reflect nearly three decades of experience in the design and manufacture of precision instruments

More information

Regulator Options and Accessories

Regulator Options and Accessories Regulator Options and Accessories Regulator accessories are available separately or mounted on Swagelok regulators. Some accessories limit regulator pressure or temperature ratings. Additional materials,

More information

Tubing and Accessories

Tubing and Accessories Section 7 Tubing and Accessories Inch Industrial Tubing................................FIT-7-2 Metric Industrial Tubing...............................FIT-7-3 Inch D.O.T. Tubing...................................FIT-7-3

More information

NOTE: If the HF body is stamped HFK, then the cage is replaceable. HF N E S C B 2 H C 5 FT 3/8 x 1/2 ODF S/T Valve Series

NOTE: If the HF body is stamped HFK, then the cage is replaceable. HF N E S C B 2 H C 5 FT 3/8 x 1/2 ODF S/T Valve Series The HF series is a balanced ported valve designed for refrigeration, air conditioning and heat pump applications. Features Stainless steel replaceable power element eliminates corrosion and prevents valve

More information

Centro-Matic Automatic Lubrication Systems System Controls

Centro-Matic Automatic Lubrication Systems System Controls Selecting the right controls for your automated lubrication system is one of the last steps in the design process. Several different models may be chosen to control power-operated pumps, depending on the

More information

Nitrogen Gas Booster Users Guide

Nitrogen Gas Booster Users Guide Nitrogen Booster Users Guide Strömsholmen AB Box 216, 573 23 Tranås, Sweden Tel +46 140 571 00, Telefax +46-140-571 99 www.kaller.com 8200-1263-01 Index of contents 1. Introduction... 4 2. Operating Procedures...

More information

REAL CHAMBERS CORPORATION SQL PRE-INSTALLATION/ SITE PREPARATION MANUAL

REAL CHAMBERS CORPORATION SQL PRE-INSTALLATION/ SITE PREPARATION MANUAL REAL CHAMBERS CORPORATION SQL PRE-INSTALLATION/ SITE PREPARATION MANUAL Real Chambers Corporation 10392 E. 48 th Avenue Denver, CO 80238 USA 23001048 Rev. E 1 of 7 TABLE OF CONTENTS OVERVIEW... 3 SAFETY...

More information

Veriflo Pressure Regulators

Veriflo Pressure Regulators Hydraulik - Pneumatik Steffen Haupt Moritzer Straße 35 01589 Riesa Telefon: 03525 6801-0 Telefax: 03525 680120 info@haupt-hydraulik.de Veriflo Pressure Regulators 4511 November 2003 KATALOG Vertrieb: Frau

More information

needle valves Needle Valves Index At a Glance 1

needle valves Needle Valves Index At a Glance 1 Needle Valves Index At a Glance 1 1700 Series 5 Forged Body, Integral Bonnet Needle Valves 2100 Series 8 Bar Stock, Screwed Bonnet Needle Valves 2200 Series 12 Bar Stock, Screwed Bonnet Needle Valves 2219

More information

MASS FLOW CONTROLLER MF5111B. Block Diagram MF5143B MF5141B 5 SCCM ~ 20 SLM 30 ~ 200 SLM. Mass Flow Controller (N/C) 400 SLM FROM SET POINT

MASS FLOW CONTROLLER MF5111B. Block Diagram MF5143B MF5141B 5 SCCM ~ 20 SLM 30 ~ 200 SLM. Mass Flow Controller (N/C) 400 SLM FROM SET POINT Specifications Sheet No.SPEC-2112E (2nd Edition) MF5100B MASS FLOW CONTROLLER OUTLINE THE MODEL MF5100B MASS FLOW CONTROLLER FEATURES EXTENDED CAPABILITY OF RANGES UP TO 400 SLM, HIGHER TERMPERATURE STABILITY

More information

CONNECTIONS FOR PORTABLE LIQUID CYLINDERS

CONNECTIONS FOR PORTABLE LIQUID CYLINDERS CONNECTIONS FOR PORTABLE LIQUID CYLINDERS AIGA 019/05 Asia Industrial Gases Association 3 HarbourFront Place, #09-04 HarbourFront Tower 2, Singapore 099254 Tel : +65 6276 0160 Fax : +65 6274 9379 Internet

More information

Turbo Tech 103 (Expert)

Turbo Tech 103 (Expert) Turbo Tech 103 (Expert) This article is a bit more involved and will describe parts of the compressor map, how to estimate pressure ratio and mass flow rate for your engine, and how to plot the points

More information

Plumbing Engineering & Design Handbook of Tables

Plumbing Engineering & Design Handbook of Tables American Society of Plumbing Engineers Plumbing Engineering & Design Handbook of Tables American Society of Plumbing Engineers 8614 W. Catalpa Avenue, Suite 1007 Chicago, IL 60656-1116 Chapter 1 Manning

More information

1805 Series Relief Valves

1805 Series Relief Valves October 2011 1805 Series Relief Valves P1026 1805G Type 1805-2 Type 1805-4 Figure 1. Typical 1805 Relief Valves Introduction The 1805 Series relief valves are designed for use in farm tap applications

More information

Series PVP Variable Volume Piston Pumps

Series PVP Variable Volume Piston Pumps Series PVP Variable Volume Piston Pumps Catalog HY28-2662-CD/US Revised June, 212 hpm12-1.p65, lw, jk 1 Notes Series PVP hpm12-1.p65, lw, jk 2 Introduction Series PVP Series Sizes 6-14 Phased Out For Reference

More information

HOW TO SIZE A PRESSURE REGULATOR

HOW TO SIZE A PRESSURE REGULATOR CHOOSING THE CORRECT REGULATOR HOW TO SIZE A PRESSURE REGULATOR In order to choose the correct regulator the following information is needed: - Function: Pressure reducing or backpressure control? - Pressure:

More information

BASIC UNDERSTANDING OF FLOW CALCULATIONS AND ESTIMATES MAKES SIZING VALVES SIMPLER

BASIC UNDERSTANDING OF FLOW CALCULATIONS AND ESTIMATES MAKES SIZING VALVES SIMPLER BASIC UNDERSTANDING OF FLOW CALCULATIONS AND ESTIMATES MAKES SIZING VALVES SIMPLER Valve size often is described by the nominal size of the end connections but a more important measure is the flow that

More information

4 Posiflow Proportional Solenoid Valves

4 Posiflow Proportional Solenoid Valves 4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/4" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Flow rate can also be regulated by a range of electrical inputs (sensors,

More information

In-Line Electronic Flow Switches

In-Line Electronic Flow Switches In-Line Electronic Flow Switches Industries Petrochemical Refining Oil Production Water Treatment Pharmaceutical Food and Beverage Pulp and Paper Power Production Gas Processing Mining Biotechnology Semiconductor

More information

An Introduction to Liquid Pipeline Surge Relief. Technical Guide July 2015

An Introduction to Liquid Pipeline Surge Relief. Technical Guide July 2015 An Introduction to Liquid Pipeline Surge Relief Technical Guide July 2015 Technical Guide The Importance of Surge Relief In many applications, such as pipelines, storage terminals and marine loading and

More information

ball valves General Purpose Ball Valves Index At a Glance 2 Flomite 71 Series 4 2-Way valves

ball valves General Purpose Ball Valves Index At a Glance 2 Flomite 71 Series 4 2-Way valves General Purpose Ball Valves Index At a Glance 2 Flomite 71 Series 4 2-Way valves Rotoball 72 Series 9 2-Way valves Ultramite 70 Series 12 2- & 3-Way valves Selectomite 71 & 76 Series 19 3-Way Ball Valves

More information

GTM PORTABLE GAS TRANSPORT. a breakthrough in high pressure gas transports, holding twice as much a comparable steel transports at 40% of the weight

GTM PORTABLE GAS TRANSPORT. a breakthrough in high pressure gas transports, holding twice as much a comparable steel transports at 40% of the weight GTM PORTABLE GAS TRANSPORT a breakthrough in high pressure gas transports, holding twice as much a comparable steel transports at 40% of the weight Transporting high pressure gases with current applications

More information

DESCRIPTION. Refer to Figure 2 below. 1. The low pressure compressor stage (A) compresses the air to about 43.5 psi (3 Bar[g]).

DESCRIPTION. Refer to Figure 2 below. 1. The low pressure compressor stage (A) compresses the air to about 43.5 psi (3 Bar[g]). DESCRIPTION The N 2 Nitrogen Generator is designed for use on tap changers, breakers, main tanks or any other electrical device requiring a gas blanketed enclosure. The unit produces nitrogen by separating

More information

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES 2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES DIRECT ACTING Brochure N-289 SPECIFICATIONS Port Size: 1/8 and1/4 Solenoid Valve for air, oil, water and other fluids Flow Direction:

More information

TEST REPORT for the ARID TECHNOLOGIES VAPOR RECOVERY UNIT installed in LANTANA, FL

TEST REPORT for the ARID TECHNOLOGIES VAPOR RECOVERY UNIT installed in LANTANA, FL Project No. 148 TEST REPORT for the ARID TECHNOLOGIES VAPOR RECOVERY UNIT installed in LANTANA, FL Prepared for: Mr. Ted Tiberi Arid Technologies, Inc. 130 North LaGrange Rd. LaGrange, IL 60525 Prepared

More information

U.L. Listed Beverage Regulators Cylinder Gas Pressure (CO 2 ) Regulators for Soft Drink and Beer dispensing systems.

U.L. Listed Beverage Regulators Cylinder Gas Pressure (CO 2 ) Regulators for Soft Drink and Beer dispensing systems. Section 12 U.L. Listed Beverage Regulators Cylinder Gas Pressure (CO 2 ) Regulators for Soft Drink and Beer dispensing systems. R84 Regulator and C84 Regulator Configurations for Soft Drink Carbonator

More information

MODULUS ELASTICITY REPORT

MODULUS ELASTICITY REPORT MODULUS OF ELASTICITY REPORT September 24 th, 2003 Report Prepared By: Sean Mulligan Testing Performed By: Bob Thompson Chuck Cook Donita Weatherspoon Modulus of Elasticity Report PURPOSE The purpose of

More information

Model 143-6 Residential Service Regulators. R-1303 Rev. 4

Model 143-6 Residential Service Regulators. R-1303 Rev. 4 Model 4-6 Residential Service Regulators R-0 Rev. 4 Model 4-6 Service Regulators equal outstanding performance, utility, and dependability with value. Best Buy, By Far The 4-6 Service Regulator The 4-6

More information

Governor Gas Regulator

Governor Gas Regulator Governor Gas Regulator ANSI Z21.80a CSA 6.22a-2005 Inlet Pressures 25" W.C. to 5 PSIG Pressures To 2 PSIG Governor Introduction Pietro Fiorentini s Governor line of gas regulators are designed to comply

More information

RESPONSE TIME INDEX OF SPRINKLERS

RESPONSE TIME INDEX OF SPRINKLERS , Number l, p.1-6, 29 RESPONSE TIME INDEX OF SPRINKLERS C.K. Sze Department of Building Services Engineering, The Hong Kong Polytechnic University, Hong Kong, China ABSTRACT The Plunge test would be carried

More information

Series Regulators - Pressure Reducing

Series Regulators - Pressure Reducing 26-1000 Series Regulators - Pressure Reducing D26100538X012 Specifications For other materials or modifications, please consult TESCOM. OPERATING PARAMETERS Pressure rating per criteria of ANSI/ASME B31.3

More information

Unit 2 Gas Regulating Devices

Unit 2 Gas Regulating Devices 2-1 Unit 2 Gas Regulating Devices GOAL On completion of this unit, the student should have an understanding of the principles of operation, correct techniques of use and safety systems of pressure regulators

More information

Lecture 8 Gasification: Material and Heat Balance

Lecture 8 Gasification: Material and Heat Balance Lecture 8 Gasification: Material and Heat Balance The following diagram shows the input of materials like coal, air and steam in a gasifier and the outputs are producer gas, ashes, tar and soot. Coal Air

More information

MG-101 User s Manual

MG-101 User s Manual GE Measurement & Control Moisture MG-101 User s Manual 910-115 Rev. E March 2012 GE Measurement & Control MG-101 Field Moisture Calibration System User s Manual 910-115 Rev. E March 2012 www.ge-mcs.com

More information

FLUID MECHANICS. TUTORIAL No.7 FLUID FORCES. When you have completed this tutorial you should be able to. Solve forces due to pressure difference.

FLUID MECHANICS. TUTORIAL No.7 FLUID FORCES. When you have completed this tutorial you should be able to. Solve forces due to pressure difference. FLUID MECHANICS TUTORIAL No.7 FLUID FORCES When you have completed this tutorial you should be able to Solve forces due to pressure difference. Solve problems due to momentum changes. Solve problems involving

More information

needle valves Needle Valves Index At a Glance Series 5

needle valves Needle Valves Index At a Glance Series 5 Needle Valves Index At a Glance 1 1700 Series 5 Forged Body, Integral Bonnet Needle Valves 2100 Series 8 Bar Stock, Screwed Bonnet Needle Valves 2200 Series 12 Bar Stock, Screwed Bonnet Needle Valves 2219

More information

LiquidLens UPW Polishing System. Superior cleanliness, TOC reduction, thermal stability and process performance for all UPW applications

LiquidLens UPW Polishing System. Superior cleanliness, TOC reduction, thermal stability and process performance for all UPW applications Contamination CONTROL SOLUTIONS LiquidLens UPW Polishing System Superior cleanliness, TOC reduction, thermal stability and process performance for all UPW applications superior cleanliness, process stability,

More information

B34 Commercial & Industrial Regulator. Advanced Metering and Regulation Technology at Work.

B34 Commercial & Industrial Regulator. Advanced Metering and Regulation Technology at Work. IMAC Systems, Inc. 90 Main Street, PO Box 1605 Tullytown, PA 19007 Tel. 1-800-955-4GAS (215) 946-2200 Fax:(215) 943-2984 www.imacsystems.com B34 Commercial & Industrial Regulator Advanced Metering and

More information

Ball Valves Subsea Series

Ball Valves Subsea Series Ball Valves Subsea Series Internal Pressures to 20,000 psi (1379 bar) Water Depths to 12,500 ft (3810 meters) Parker Autoclave Engineers subsea ball valves have been designed to fulfill the ever growing

More information

THE ADVANCED DENTAL DRY VAC DENTAL SYSTEMS

THE ADVANCED DENTAL DRY VAC DENTAL SYSTEMS TM THE ADVANCED DENTAL DRY VAC 100% Oil & Water Free Suction Systems Compact & Expandable Suction Systems Custom Engineered Large Scale Systems Portable Surgical Suction Systems The creation of vacuum

More information

Pressure-Reducing Regulator Flow Curves

Pressure-Reducing Regulator Flow Curves www.swagelok.com Pressure-educing egulator low Curves Technical Bulletin Scope Selecting a regulator for an application first requires review of its performance capabilities and their alignment with the

More information

GENERAL & HIGH PRESSURE CHECK VALVES. VC Series. Kor-Lok USA

GENERAL & HIGH PRESSURE CHECK VALVES. VC Series.  Kor-Lok USA GENERAL & HIGH PRESSURE CHECK VALVES VC Series www.korlokusa.com Kor-Lok USA Features Valve Series Cracking Maximum Working VC3 General Purpose Fixed 3000 psig 207 bar VC6 High Fixed 6000 psig 413 bar

More information

pumping liquids JET PUMP TECHNICAL DATA

pumping liquids JET PUMP TECHNICAL DATA Section 000 Bulletin 00 Issued 5/87 Replaces /8 JET PUMP TECHNICAL DATA pumping liquids This technical bulletin includes general information about Penberthy Jet Pumps plus specific details for selecting

More information

Turn to the NEW PRODUCT. Pros HARRIS HVAC EQUIPMENT. THE HARRIS PRODUCTS GROUP Orders:

Turn to the NEW PRODUCT. Pros HARRIS HVAC EQUIPMENT. THE HARRIS PRODUCTS GROUP  Orders: NEW PRODUCT Orders: 1.800.733.4533 Turn to the Pros HARRIS HVAC EQUIPMENT 1 HVAC EQUIPMENT INTRODUCING A NEW SERIES OF BRAZING PRODUCTS FEATURING THE MOST POPULAR INDUSTRY STANDARD CONNECTIONS. PROFESSIONALS

More information

CONDENSED CATALOG CC

CONDENSED CATALOG CC CONDENSED CATALOG CC-2011 www.versa-valves.com e-mail: sales@versa-valves.com THE COMMITMENT CONTINUES Fluid Power is our business. It is our only business, so we have to be good at it. Since its beginning

More information

WHAT ARE THE SPECIFICATIONS FOR THE NITROGEN GAS USED IN JOULE THOMSON REFRIGERATORS?

WHAT ARE THE SPECIFICATIONS FOR THE NITROGEN GAS USED IN JOULE THOMSON REFRIGERATORS? MMR Technologies, Inc. WHAT ARE THE SPECIFICATIONS FOR THE NITROGEN GAS USED IN JOULE THOMSON REFRIGERATORS? Joule Thomson refrigerators operate using high pressure gas to cool a sample stage with high

More information

High Pressure Solenoid Valves

High Pressure Solenoid Valves High Pressure Solenoid Valves Available for Quick Delivery Controls the flow of Gases & Liquids up to 15,000 PSIG Natural Gas, Hydrogen & other High Pressure Gases High Pressure Cryogenics Flammable Liquids

More information

Installation and Operating Manual Model F1000C Model F1000PG Model F1020C Model F1020PG

Installation and Operating Manual Model F1000C Model F1000PG Model F1020C Model F1020PG Installation and Operating Manual Model F1000C Model F1000PG Model F1020C Model F1020PG www.ipsystemsusa.com Contents Safety Warnings...2 Items supplied...3 Description...3 Installation...4 Operation...4

More information

Aerospace & Defense. Pressure control solutions for your industry.

Aerospace & Defense. Pressure control solutions for your industry. Aerospace & Defense Pressure control solutions for your industry. Years of experience innovative solutions TESCOM is an experienced provider of high quality regulators, valves, manifolds, custom assemblies

More information

CHAPTER 25 IDEAL GAS LAWS

CHAPTER 25 IDEAL GAS LAWS EXERCISE 139, Page 303 CHAPTER 5 IDEAL GAS LAWS 1. The pressure of a mass of gas is increased from 150 kpa to 750 kpa at constant temperature. Determine the final volume of the gas, if its initial volume

More information

Outdoor Cooking. Gas pressure Regulators & Accessories 2012 EDITION LPG & NATURAL GAS REGULATORS RE-02 DIVISION

Outdoor Cooking. Gas pressure Regulators & Accessories 2012 EDITION LPG & NATURAL GAS REGULATORS RE-02 DIVISION Outdoor Cooking Gas pressure Regulators & Accessories 2012 EDITION RE-02 Outdoor cooking Product index 1 - Introduction P.4 1.1 Gas pressure regulators P.4 1.2 Low pressure installations P.4 1.3 High pressure

More information

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version Electronic pressure measurement Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version WIKA data sheet PE 81.66 Applications Machine building

More information

k is change in kinetic energy and E

k is change in kinetic energy and E Energy Balances on Closed Systems A system is closed if mass does not cross the system boundary during the period of time covered by energy balance. Energy balance for a closed system written between two

More information

STC 2P Series Solenoid Valves

STC 2P Series Solenoid Valves STC 2P160-250 Series Solenoid Valves 2P160-250 Series Solenoid Valve Specifications Valve Model 2P160-1/2 2P200-3/4 2P250-1 Valve Type Action 2 Way, Normally Closed (NC) Direct Lift Diaphragm, Uni-Directional

More information

Equivalents & Conversion Factors 406 Capacity Formulas for Steam Loads 407 Formulas for Control Valve Sizing 408-409

Equivalents & Conversion Factors 406 Capacity Formulas for Steam Loads 407 Formulas for Control Valve Sizing 408-409 Engineering Data Table of Contents Page No. I II Formulas, Conversions & Guidelines Equivalents & Conversion Factors 406 Capacity Formulas for Steam Loads 407 Formulas for Control Sizing 408-409 Steam

More information

UNDERSTANDING REFRIGERANT TABLES

UNDERSTANDING REFRIGERANT TABLES Refrigeration Service Engineers Society 1666 Rand Road Des Plaines, Illinois 60016 UNDERSTANDING REFRIGERANT TABLES INTRODUCTION A Mollier diagram is a graphical representation of the properties of a refrigerant,

More information

Nitrogen Gas Generators MAXIGAS Pure & Simple

Nitrogen Gas Generators MAXIGAS Pure & Simple gas generators Nitrogen Gas Generators MAXIGAS Pure & Simple nitrogen generators from domnick hunter - the safe and reliable alternative to cylinder and liquid gas at a fraction of the cost How important

More information

P3000 Series. Pneumatic Deadweight Testers Model P3000. Technical Data. Features

P3000 Series. Pneumatic Deadweight Testers Model P3000. Technical Data. Features P3000 Series Pneumatic Deadweight Testers P3000 Technical Data Features Pressure ranges from Vacuum through 2 000 psi (140 bar) Accuracy better than 0.015 % of reading. (Increased accuracy option of 0.008

More information

Fuel Injection Pump (Up to 97 MY) Remove And Install ( )

Fuel Injection Pump (Up to 97 MY) Remove And Install ( ) Fuel Injection Pump (Up to 97 MY) Remove And Install (23 414 0) Special Tools 23018 23044 23-018 Dial gauge holding fixture, injection pump timing 23-044 Remover, injection pump sprocket Proprietary Tools

More information

TABLE OF CONTENTS. Tank Repair and Remanufacturing Emergency Oxygen Inlet Boxes...11 Check Valves with Brazed Copper Extensions...

TABLE OF CONTENTS. Tank Repair and Remanufacturing Emergency Oxygen Inlet Boxes...11 Check Valves with Brazed Copper Extensions... TABLE OF CONTENTS Acme Complete Medical Gas Delivery Systems...1 Medical Source Equipment Hospital Pressure Control Manifolds...2 Reserve Manifolds...3 Vaporizer Switchover Manifold...3 Local Signal Panel...4

More information

batimet Systemdetails

batimet Systemdetails batimet TA35 DSP DSE System elements type catalog 5921001 007 : 0 5921001 elements type catalog 5921002 008 : 0 5921002 elements type catalog 5921003 009 : 0 5921003 elements type catalog 5921501 010 :

More information