European Technical Approval No. ETA-06/0006 (English language translation, the original version is in French language) Version of 28 st July 2011

Size: px
Start display at page:

Download "European Technical Approval No. ETA-06/0006 (English language translation, the original version is in French language) Version of 28 st July 2011"

Transcription

1 Service d'études sur les transports, les routes et leurs aménagements 46 avenue Aristide Briand BP BAGNEUX CEDEX Tel : + 33 (0) Fax : + 33 (0) MEMBRE DE L'EOTA MEMBER OF EOTA European Technical Approval No. ETA-06/0006 (English language translation, the original version is in French language) Version of 28 st July 2011 Nom commercial Trade name Détenteur de l'ate Holder of approval Type générique et utilisation prévue du produit de construction Generic type and use of construction product Valid from: to: Producteur du procédé Kit manufacturer Procédé de précontrainte VSL VSL Post-Tensioning System VSL INTERNATIONAL Ltd. Saegestrasse, 76 CH-3098 KOENIZ Procédés de précontrainte des structures par posttension (Communément appelés procédés de précontrainte) Post-tensioning Kits for prestressing of Structures (Commonly called Post-Tensioning Systems) 31/03/ /03/2016 CTT-Stronghold, SA Ribera del Congost, s/n SP Les Franqueses del Vallès (Barcelona) Cet Agrément Technique Européen est un renouvellement de validité de This European Technical Approval extends ETA-06/0006 valide du 31/07/2006 au 30/07/2011 ETA-06/0006 with validity from 31/07/2006 to 30/07/2011 Le présent agrément technique européen contient This European Technical Approval contains 8+( ) pages incluant 3 annexes (0, 1, 2) faisant partie intégrante du document. 8+( ) pages including 3 annexes ( 0, 1, 2) which form an integral part of the document. Organisation pour l'agrément Technique Européen European Organisation for Technical Approvals

2 European Technical Approval No. ETA-06/ I - LEGAL BASIS AND GENERAL CONDITIONS 1- This European Technical Approval is issued by SETRA in accordance with: - Council Directive 89/106/EEC of 21 December 1988 on the approximation of laws, regulations and administrative provisions of Member States relating to construction products 1, modified by Council Directive 93/68/EEC 2 and Regulation (EC) N o 1882/2003 of the European Parliament and of the Council 3 ; - Décret n du 8 juillet concernant l'aptitude à l'usage des produits de construction - Common Procedural Rules for Requesting, Preparing and the Granting of European Technical Approvals set out in the Annex to Commission Decision 94/23/EC 5 ; - ETAG 013, Edition June 2002, Post-Tensioning Kits for Prestressing of Structures. 2 - SETRA is authorized to check whether the provisions of this European Technical Approval are met. Checking may take place in the manufacturing plant(s). Nevertheless, the responsibility for the conformity of the products to the European Technical Approval and for their fitness for the intended use remains with the holder of the European Technical Approval. 3 - This European Technical Approval is not to be transferred to manufacturers or agents of manufacturers other than those indicated on page 0, or manufacturing plants other than those indicated on page 0 of this European Technical Approval. 4 - This European Technical Approval may be withdrawn by SETRA, in particular pursuant to information by the Commission according to Article 5 1 of Council Directive 89/106/EEC. 5 - Reproduction of this European Technical Approval including transmission by electronic means shall be in full. However, partial reproduction can be made with the written consent of SETRA. In this case partial reproduction has to be designated as such. Texts and drawings of advertising brochures shall not contradict or misuse the European Technical Approval. 6 - The European Technical Approval is issued by the approval body in its official language(s). This (These) version(s) corresponds (correspond) fully to the version circulated in EOTA. Translations into other languages have to be designated as such. 1 Official Journal of the European Communities N o L 40, , p Official Journal of the European Communities N o L 220, , p. 1 3 Official Journal of the European Union N o L 284, , p. 1 4 JORF du 14 juillet Official Journal of the European Communities N o L 17, , p. 34

3 European Technical Approval No. ETA-06/ II - SPECIFIC CONDITIONS CONCERNING THE EUROPEAN TECHNICAL APPROVAL 1 - Product definition and intended use Product definition The VSL Post-Tensioning System consists, for convenience purposes, of two systems that rely upon a set of common basic components: the VSL Multistrand System and the VSL Slab System. According to this System, cables are considered to be primarily composed of ducts, tendons (using the 0.6" 'normal' or 'super' strand, i.e. Ø 15.2 or Ø 15.7, those defined in the White Draft pr EN : "Prestressing steels - Strands" or individually greased and sheathed monostrand complying with ETAG 013 Annex C.1), anchorages and/or couplers and other components such as protective products necessary for ensuring either a permanent level of prestressing (during the entire reference life cycle) or a temporary one (over a limited period) for civil engineering structural elements, buildings or any other type of construction. As long as EN does not exist 7-wire strands in accordance with national provisions shall be used. The VSL Multistrand System (from 1 to 55 strand cables), defined in Annex 1 and intended more for massive civil engineering parts, is used along with the strands specified above and the following components: - ducts: - metallic: corrugated steel strip sheaths, steel tubes, - made of plastic, the VSL PT-PLUS ducting, polyethylene or polypropylene sheaths or tubes, - anchorages: - active or passive type E (1 to 55 strands), type CS (7 to 37 strands), type GC (3 to 37 strands),, type NC (55 strands) and NC-U (55 strands), - using bond type H (1 to 37 strands), - fixed couplers type K (3 to 37 strands) and movable couplers type V (3 to 37 strands); - injection products: - for rigid injection: with a cement base, in accordance with EN for flexible injection: with a grease base, with a wax base. Filling materials covered by an ETA may also be employed. The VSL Slab System (1 to 4 strands), defined in Annex 2 and primarily intended for thin construction elements for building or bridge decks, is used along with the strands specified above and either bare strands for the system with injection or individually greased and sheathed for the system without injection: - ducts for the system with injection: the circular or flat corrugated steel strip sheaths, the circular or flat VSL PT-PLUS duct, - anchorages: - active or passive type S 6-1 (1 strand), S 6-1 PLUS (1 strand) and type S 6-4 (4 strands), - embedded dead end type SF 6-1 (1 strand) and SF 6-1 PLUS (1strand), - using bond: type H for the system with injection applied to internal bonded tendons only. - injection products for the system with injection: with a cement base, in accordance with EN 447. Filling materials covered by an ETA may also be employed Intended use The VSL Post-Tensioning System has been designed to ensure the equilibrium of structures or of sections of structures submitted to the gravity effects, live load effects, climatic effects or any other type of action as well as to the imposed set of deformations. The VSL Post-Tensioning System may be used for: - new structural works, - the repair and strengthening of existing structures.

4 European Technical Approval No. ETA-06/ The VSL Post-Tensioning System may also be employed in structures made of other materials than concrete; this could entail structures made of concrete, masonry, steel, cast iron, wood or combinations of several materials. The tendons assembled as part of the VSL Post-Tensioning System may have the following basic use categories: - internal bonded tendon for concrete and composite structures, - internal unbonded tendon for concrete and composite structures, - external tendon for concrete structures with a tendon path situated outside the cross section of the structure or member but inside its envelope. (Cables for ground and rock anchors, external cables with a layout positioned beyond the structural envelope or the structural component, and stay cables are not covered by the present ETA). completed with the following optional use categories: - restressable tendon (internal or external), - exchangeable tendon (internal or external), - cryogenic applications, - internal bonded tendon with plastic duct, - encapsulated tendon, - electrically isolated tendon, - tendon for use in structural steel or composite construction as external tendon, - tendon for use in structural masonry construction as internal and/or external tendon, - tendon for use in structural timber as internal and/or external tendon. The tables presented in Chapters 1.4 and 3.4 of Annexes 1 and 2 establish the categories possible for each of the approved anchorages. 1.3 Working life The provisions, test and assessment methods in the ETAG 013 have been written based upon the assumption that the estimated design working life (nominal design value of the intended life of a structure) of the PT System is the same as the one specified in the Eurocodes relevant for the structure in which it is intended to be used provided that the PT System is subject to appropriate use and maintenance (see Chapter 7 of ETAG 013). Eurocode 1 specifies 100 years design working life for bridges and other engineering structures. These provisions are based upon the current state of the art and the available knowledge and experience. The indication given on the design working life of a product cannot be interpreted as a guarantee given by the producer (or the Approvals Body) but is regarded only as a means for choosing appropriate components and materials in relation to the expected economically reasonable design working life of structures for the works. The relevant Eurocodes would be the following: ENV 1990 "Eurocode 0": Basis of structural design ENV 1991 "Eurocode 1": Actions on structures ENV 1992 "Eurocode 2": Design of concrete structures ENV 1993 "Eurocode 3": Design of steel structures ENV 1994 "Eurocode 4": Design of composite steel and concrete structures ENV 1995 "Eurocode 5": Design of timber structures ENV 1996 "Eurocode 6": Design of masonry structures 2 - Product characteristics and verification methods Product characteristics The components of the VSL Post-Tensioning System comply with the drawings and conditions described in Annexes 1 and 2 of this European Technical Approval. More detailed information related to confidential specifications (e.g.: materials, processing, surface, dimensions, tolerances, manufacturing methods and control procedures) are included in the Technical Evaluation dossier concerning this European Technical Approval, which has been deposited at the

5 European Technical Approval No. ETA-06/ Approval Body. This set of information is also to be sent, whenever necessary, to the Certification Body responsible for Attestation of Conformity. Essential requirements 1 (mechanical resistance and stability) and 3 (hygiene, health and the environment) from Appendix I of the Construction Products Directive have been fulfilled. For the PT System, the other requirements need not to be complied with. Only product characteristics in relation to essential requirements 1 and 3 are to be verified. It should be pointed out that, depending on their specific nature, some prestressed structures or parts of prestressed structures may need to satisfy other requirements in respect to fire safety Verification methods Assessment of the fitness for use of the PT System with essential requirement 1 related to "mechanical resistance and stability" was carried out, as stipulated in the European Technical Approval Guide focusing on post-tensioning kits for prestressing of structures (ETAG 013). The performances assessed in accordance with ETAG 013 allow to fulfill all relevant essential requirements. Such performances deal for the most part with: resistance to static loads, effective load transfer to the structure, and resistance to fatigue. A set of specific tests were carried out as stated in ETAG 013 for the following optional use categories : electrical insulation and cryogenic applications. The methods for verifying, evaluating and assessing suitability and test procedures comply with those detailed in ETAG 013. According to the kit manufacturer s declaration, the post-tensioning kit does not contain any dangerous substances. In addition to the specific clauses relating to dangerous substances contained in this European Technical Approval, there may be other requirements applicable to the products falling within its scope (e.g. transposed European legislation and national laws, regulations and administrative provisions). In order to meet the provisions of the EU Construction Products Directive, these requirements need also to be complied with, when and where they apply. This statement has been highlighted in Chapter 5 entitled "Injection and sealing" of both Annexes 1 and Evaluation, Attestation of Conformity and CE marking The attestation of conformity system The system of attestation of conformity specified by the European Commission in mandate 98/456/EC 6 is the system 1+, with audit testing of samples, described in Council Directive (89/106/EEC) Annex III and is detailed as follow: Tasks for the Kit Manufacturer (see Section 3.2.1): 1) Factory production control, 2) Further testing of samples taken at the factory by the manufacturer in accordance with a prescribed test plan (see Annex 0); Tasks for the Certification Body (see Section 3.2.2): 1) Initial type testing of the product, 2) Initial inspection of factory and of factory production control (FPC), 3) Continuous surveillance, assessment and approval of factory production control (FPC) 4) Audit testing of samples Responsibilities Tasks for the Kit Manufacturer General responsibilities of the Kit Manufacturer The Kit Manufacturer shall keep available an updated list of all components manufacturers. 6 Official Journal of the European communities L201/112 of 3 July 1998

6 European Technical Approval No. ETA-06/ This list is to be provided to the Certification Body. Another copy may also be made available to the Approval Body. The Kit Manufacturer is responsible for the production and quality of components manufactured or ordered. At least once a year, each components manufacturer has to be audited by the kit manufacturer. Each audit report shall be made available to the Certification Body. These audit reports include: - Identification of the components manufacturer - Date of audit of components manufacturer - Summary of the results and records of the FPC since last audit - Summary of the complaint records - Evaluation of the components manufacturer concerning FPC - Specific remarks as relevant - Clear and unique statement whether the requirement of the ETA are met - Name and position of signatory - Date of signature - Signature. At least once a year specimens are taken by the kit manufacturer from at least one job site. One series of single tensile element tests are performed according to Annex 0 (annex E3 of the ETAG 013) by the kit manufacturer with these specimens. One series of single tensile element tests are performed with components from only one site. The results of these test series are made available to the Certification Body. These reports include: - Identification of the job site where the components have been taken - Date of sampling - Identification of the components (e.g. anchor head, wedges, strand, ) - Place and date of testing - Summary of the results including a test report according to Annex E.3 of ETAG Specific remarks as relevant - Name and position of signatory - Date of signature - Signature. The kit manufacturer makes available for at least 10 years all records of relevant results concerning the ETA and the audit reports concerning the components manufacturers Factory Production Control (FPC) General The kit manufacturer exercises permanent internal control of the production. All the elements, requirements and provisions adopted by the kit manufacturer are documented in a systematic manner in the form of written policies and procedures. This control system ensures that the PT System is in conformity with the European Technical Approval. The Factory Production Control is in accordance with the control plan of VSL named QM relating to the European Technical Approval 06/0006 issued on which is part of the technical documentation of this european technical approval. The control plan is laid down in the context of the factory production control system operated by the manufacturer and deposited at SETRA. The basic elements of the control plan comply with ETAG 013 annex E1. The results of the factory production control shall be recorded and evaluated in accordance with the provisions of the control plan. FPC and the prescribed test plan are according to Annex 0, which address the following aspects: - manufacturing - distribution and delivery to job site. FPC system complying with EN ISO 9001 : 2000 and which addresses the requirements of the ETA is recognized as satisfying the FPC requirements of the Directive. Parts of the FPC may be transferred to an independent test laboratory. Nevertheless, the kit manufacturer has the full responsibility for all results of the FPC.

7 European Technical Approval No. ETA-06/ Control of the PT System components and materials The characteristics of incoming materials which comply with a harmonized European technical specification, having met the corresponding Attestation of Conformity procedure, are considered satisfactory and need, except in case of justified doubt, no further checking. All materials are to be in accordance with the requirements of the ETA and the corresponding specifications of the kit manufacturer. Where harmonized technical specifications are not available, materials according to specifications valid in the place of use may be used provided that their use is compatible with the results of approval tests. Otherwise, the specifications are given in the ETA Inspection and testing The validity of the type and frequency of checks / testing conducted during production and on the final product has to be considered as a function of the production process. This includes verification conducted during production, on properties that cannot be inspected at a later stage and verification on the final product. These include: - Definition of the number of samples taken by the kit manufacturer - Material properties e.g. tensile strength, hardness, surface finish, chemical composition, - Determination of the dimensions of components - Check correct assembly - Documentation of tests and test results. All tests are performed according to written procedures with suitable calibrated measuring devices. All test results are recorded in a consequent and systematic way. The prescribed test plan relative to the PT System (see Annex 0) complies with stipulations in Annex E.1 of ETAG 013, including the minimum test frequencies to perform Control of non-conforming products Products which are considered as not conforming with the ETA are immediately marked and separated from such products which comply. The prescribed test plan addresses control of non-conforming products Complaints ETA Technical File includes provisions to keep records of all complaints about the PT System Tasks of the Certification Body (CB) The CB may act with its own resources or subcontract inspection tasks and testing tasks to inspection bodies and testing laboratories Initial type-testing The results from tests performed during the approval procedure and then evaluated by the Approval Body may be used by the Certification Body as initial type testing as required in the ETAG Initial assessment of factory and factory production control The Certification Body assesses both the factory capacities and the factory production control performed by the kit manufacturer in order to ensure that, in compliance with the prescribed test plan, the manufacturing resources and FPC are able to guarantee continuous and consistent manufacturing of PT System components in accordance with ETA specifications Continuous surveillance The Certification Body shall perform surveillance inspections, Components Manufacturers inspections and sample extractions either in the factories or on the job sites for the purpose of conducting independent tests under its responsibility. Continuous surveillance and FPC evaluation are to proceed in accordance with the prescribed test plan and in compliance with conditions laid out under the "Continuous surveillance" heading found in the ETAG 013 guide and in Figure 8.1 in particular. The kit manufacturer shall be inspected at least once a year. Its FCP will be checked and according to Annex E.2, samples are taken for independent testing.

8 European Technical Approval No. ETA-06/ Each component manufacturer shall be inspected at least once during the period of validity of the ETA that is at least once in five years. The Certification Body shall provide SETRA, upon request, the results of certification and continuous surveillance. In cases of serious non conformities, related to important aspects of the performances of the posttensioning system, which can not be corrected within the deadlines, the certification body shall withdraw the certification of conformity and inform the SETRA without delay. 3.3 CE-Marking CE-marking is in accordance with the Construction Products Directive and the Guidance Paper "D" named "CE marking under the construction products directive" (EC/OEAT 04/645 Document). The delivery note, associated with the components of the PT System, shall contain the CE conformity marking which consist of the CE-symbol and: 1. The name or identifying mark of the kit manufacturer 2. The last two digits of the year in which the marking was affixed 3. The number of the Certificate of Conformity 4. The ETA number 5 See information on ETA No 06/ The use category(ies) 7. The number of the Certification Body. All other information is clearly separated from the CE-marking and the accompanying information. 4 - Assumptions under which the fitness for use of VSL PT System is favorably assessed Production This European Technical Approval document has been issued for the VSL PT System on the basis of Manufacturer Technical Dossier (MTD) submitted and verified by SETRA Any anticipated changes to the process or in the production of components that may change the MTD must be notified to SETRA, which would then decide whether change affects the ETA and, consequently, the validity of the CE-marking and whether an additional assessment with modification of this ETA would be necessary. Under all circumstances, SETRA consent is required prior to enacting the planned modifications Installation The quality of a post-tensioned structure lies not only in its effective design, but also in the quality of its execution. As regards post-tensioning, it goes without saying that the appropriate use of the PT System, component quality and system installation quality serve to influence both suitability for the intended use and the design working life. Basic information has been provided in Annexes 1 and 2 of ETA document. Although such information proves essential for purposes of comprehending PT System application, it alone remains insufficient for proceeding with the installation step. For this reason, the Post-Tensioning System has been set up for installation to be performed by a PT Specialist Company. Even though this field is submitted to the national regulatory conditions of EU Member States, it should be recalled herein that the qualification of PT Specialist Companies encompasses their aptitude (specialized equipment resources and certified staff) first to design the prestressed parts of structures and then to prepare the corresponding set of components and work tasks, install the PT System (including cable tensioning using appropriate devices) and performing the injection of protective filling material. These last two tasks are to be carried out with equipment capable of meeting the requirements associated with attaining precise measurements of certain physical magnitudes. The tasks of design and installation may be extended, under some circumstances, by means of monitoring and adjustment (whenever necessary) of the installed PT System.

9 European Technical Approval No. ETA-06/ Indications Packaging, transportation and storage Temporary protections, packaging, along with transportation and storage conditions for components of the VSL PT System have been designed to ensure availability for worksite installation without any alteration of their suitability for the particular intended use. The detailed conditions to be adopted relative to the ducts, reinforcements, anchorages and protective filling material have been set forth both in Chapter 7 of ETAG 013 and in the VSL Technical Documentation (associated with the European Technical Approval) Installation The entire set of equipment used for installing the PT System is submitted to periodic maintenance and repair operations, whenever necessary. Tensioning equipment measurement systems (pressure or force, displacement and/or movement) that get included in the verification of magnitudes for the actions applied to structures undergo calibration in compliance with: Chapter 7 of ETAG 013, the national provisions, and the set of practices prescribed in the VSL Technical Documentation (associated with the European Technical Approval).

10 Annex 0 of the European Technical Approval No. ETA-06/ Annex 0 ETA APPLICATION 1 - Commitments assumed by the ETA Holder Once installed, the VSL Post-Tensioning System makes a vital contribution both to the permanent equilibrium of structures and to their durability. In light of the terms inherent in this European Technical Approval (ETA), which serve to certify the fitness for use of the PT System, its service capabilities and its working life as well as to prescribe the resources utilized by the companies involved (see Appendix D of ETAG 013), it is essential for each of the prerequisite measures to be applied during the fabrication and installation steps that accompany the design step in promoting proper use of the PT System. In this aim, the ETA Holder agrees to apply and ensure application of this approval by the Kit Manufacturer, the Component Manufacturers and the PT Specialist Companies such that the installed PT System proves capable of satisfying the designated set of basic requirements (in compliance with Construction Products Directive, Chapter 1, Article 2.1). 2 - Responsibility of both the ETA Holder and Kit Manufacturer The components of the VSL Post-Tensioning System are produced in accordance with the conditions of the present European Technical Approval by the Kit Manufacturer and selected Component Manufacturers, using the production resources indicated and identified during inspections and on site audits performed by both the Approval and Certification Bodies. The Kit Manufacturer guarantees that all components of the PT System and relative individual components for which the ETA has been issued comply with the specifications given in the ETA. For the most important components, the following table summarizes the minimum procedures which have to be performed.

11 Annex 0 of the European Technical Approval No. ETA-06/ "Prescribed test plan" Component Item Test / Check Traceability 4 Minimum frequency Documentation Anchorage zone components Anchor plate Material 7 Check bulk 6 100% 9 "2.2" 1,6 Anchor head, Coupler Wedges, Compression fitting Test 3% 9 Detailed Yes dimensions 5 = 2 elements Visual inspection 3 Check 100% 9 No Material 7 Check full 100% 9 "3.1" 2 Detailed Test 5% 9 dimensions 5 2 elements Visual inspection 3 Check 100% 9 No Material 7 Check full 100% 9 "3.1" 2 Treatment, Test 0.5% 9 Yes hardness = 2 elements Detailed dimensions 5 Test 5% 9 = 2 elements Yes Visual inspection 3 Check 100% 9 No Current zone components Duct Material 7 Check "CE" 2 100% "CE" 2 Visual inspection 3 Check 100% No Strand Material 7 Check National 100 % "CE" 2 Diameter Test Certification Each coil No Visual inspection 3 till "CE" 2 Check Each coil No Constituents Cement 7 Check full 100% "CE" 2 of filling Admixtures, Check bulk 100% "CE" 2 material as additions,... 7 per EN 447 Monostrand Material 7 Check National 100% "CE" 8 Certification till "CE" 2 Plastic pipes Material 7 Check full 100% "CE" 2 Plastic ducts Material 7 Check full 100% "CE" 8 All samples are to be extracted at random and clearly identified. Details on sampling procedures including methods of recording as well as test methods have been agreed between the Approval Body and the Kit Manufacturer as part of the prescribed test plan. Preferably standardized sampling and test methods are used. Generally all results are reported in the test reports in such a way to enable direct comparison with the specification s data in the ETA or subsidiary documentation. Yes 1 "2.2": Test report type "2.2" according to EN (this applies to simple steel anchor plates only). 2 "3.1": Inspection certificate type "3.1" according to EN If the basis of "CE"-marking is not available, the prescribed test plan has to include appropriate measures, only for the time until the harmonized technical specification is available.

12 Annex 0 of the European Technical Approval No. ETA-06/ Visual inspections means e.g.: main dimensions, gauge testing, correct marking or labelling, appropriate performance acceptability, surface fins, kinks, smoothness, corrosion, coating, etc., as given in the prescribed test plan. 4 5 full: Full traceability of each component to its raw material. bulk: Traceability of each delivery of components to a defined point. Detailed dimensions mean measuring of all dimensions and angles according to the specifications as given in the prescribed test plan. 6 Only if the force transfer unit is a "simple plate". Otherwise appropriate procedures have to be introduced. 7 Material checks are included for information only as these are not part of the prescribed test plan. 8 If the basis of "CE"-marking is not available, the prescribed test plan has to include appropriate measures. The certificate shall be based on specific testing on the fabrication lot from which the supply has been produced, to confirm specified properties, and shall be prepared by a department of the supplier which is independent of the production department. 9 Procedure according to VSL Final Control Specifications. Note: Generally speaking, all tests, inspections, etc. are aimed at verifying that the information contained in manufacturing drawings as well as in the ultimate set of associated specifications has actually been applied to the components. During surveillance inspections, the Certification Body has to take samples of components of the PT System or the relative individual components for which the ETA has been granted for independent testing. For the most important components, the table given below summarises the minimum procedures which are performed by the Certification Body. "Audit testing" Component Item Test / Check Sampling Number of components per visit Anchor head, Coupler Material according to specification Check, test 1 Wedges, Compression fitting Single tensile element test Inclined Tube test Detailed dimensions Test Visual inspection 10 Check Material according to specification Check, test 2 Treatment Test 2 Detailed dimensions Test 1 Main dimensions, surface hardness Test 5 Visual inspection 10 Check 5 Single tensile element test Test 1 series according to Annex E.3 Inclined Tube test as per Clause Test 1 test C All samples are to be randomly selected and clearly identified. Details on sampling procedures including methods of recording as well as test methods have been agreed between the Approval Body and the Kit Manufacturer as part of the prescribed test plan. Preferably standardized sampling and test methods are used. Generally all results are reported in the test reports in such a way to enable direct comparison with the specification s data in the ETA or subsidiary documentation.

13 Annex 0 of the European Technical Approval No. ETA-06/ Visual inspections means e.g. : main dimensions, gauge testing, correct marking or labelling, appropriate performance, surface, fins, kinks, smoothness, corrosion, coating, etc. 11 Applied to special grout specified within the ETAG 013 in C.4.3 and this ETA. 3 - Responsibility assigned the ETA Holder and PT Specialist Companies The respective tasks and responsibilities of the ETA Holder and PT Specialist Companies are expressed in Appendix D of ETAG 013. Installation of the VSL Post-Tensioning System is carried out in full compliance with the present European Technical Approval, all related European level documents, and all pertinent National application documents at the Country level.

14 Annex 1 TECHNICAL DATA OF THE VSL MULTISTRAND SYSTEM

15 Annex 1 of the European Technical Approval No ETA-06/ TABLE OF CONTENTS Title Page 1. DEFINITION OF THE SYSTEM 1.1 PRINCIPLE OF THE VSL MULTISTRAND SYSTEM CHARACTERISTICS OF SYSTEM UNITS ANCHORAGES PRESENTATION OF THE ANCHORAGES LIST OF APPROVED ANCHORAGES 1.4 CATEGORIES OF USE, POSSIBILITIES AND OPTIONS USES AND OPTIONS OF THE VSL MULTISTRAND SYSTEM POSSIBILITIES OF THE VSL MULTISTRAND SYSTEM 2. STRANDS AND DUCTS 2.1 STRANDS USED DUCTING TYPES AND DIMENSIONS OF USABLE DUCTS METAL DUCTS PLASTIC DUCTS ACCESSORIES FOR INLETS, BLEED VENTS AND OUTLETS CONNECTION WITH TRUMPETS 2.3 CABLE LAYOUT STRAIGHT LENGTHS BEHIND THE ANCHORAGES RADIUS OF CURVATURE SPACING OF SUPPORTS AND TOLERANCES STRAND CUT LENGTH 2.4 INSTALLATION OF DUCTS AND STRANDS PROVISIONAL PROTECTION AND LUBRICATION CALCULATION ELEMENTS FRICTION LOSSES BASIS FOR EVALUATING ELONGATIONS SETTING OF ANCHORAGE WEDGES 3. ANCHORAGES 3.1 DESCRIPTION OF ANCHORAGE COMPONENTS LIVE END / DEAD END ANCHORAGES COUPLERS PRESENTATION AND PACKING OF ANCHORAGES 3.2 ORGANIZATION OF SUPPLY QUALITY INSTALLATION OF VARIOUS ANCHORAGES TYPE "E", "CS", "GC", "NC" and "NC-U" ACTIVE END ANCHORAGES TYPE "E", "CS", "GC",, "NC" and "NC-U" PASSIVE END ANCHORAGES TYPE "H" BOND ANCHORAGES TYPE "K" FIXED COUPLERS TYPE "V" MOVABLE COUPLERS 3.4 ANCHORAGE ARRANGEMENTS GEOMETRICAL AND MECHANICAL USE CONDITIONS CLEARANCE BEHIND STRESSING ANCHORAGES CONCRETE COVER AND ANCHORAGE SPACING 3.6 LOCAL ANCHORAGE ZONE REINFORCEMENT STRESSING 4.1 STRESSING EQUIPMENT STRESSING JACKS HYDRAULIC PUMPS MEASUREMENT INSTRUMENTS AND SYSTEMS 4.2 PROCESSES OF STRESSING AND CONTROL PROCEDURE 22

16 Annex 1 of the European Technical Approval No ETA-06/ FORCE MEASUREMENTS ELONGATION MEASUREMENTS 5. INJECTION AND SEALING 5.1 GENERAL INFORMATION INJECTION PRODUCTS PRODUCT FOR BONDED CABLES PRODUCT FOR UNBONDED CABLES 5.3 INJECTION EQUIPMENT INJECTION AND CONTROL PROCEDURE SEALING SCHEMATIC DRAWINGS 27

17 Annex 1 of the European Technical Approval No ETA-06/ CHAPTER 1 DEFINITION OF THE SYSTEM 1.1 PRINCIPLE OF THE VSL MULTISTRAND SYSTEM The cable or unit of the VSL Multistrand System is composed of a bundle of strands made of high-strength steel called a "tendon", along with the associated set of anchorages. The tendon has to be encased within a duct such as a sheath or tube, etc. The void thereby produced can potentially be filled with an injected material for the purpose of bonding with the structure and/or inhibiting corrosion. The constituting strands are those defined in the European Standard White Draft pr EN : "Prestressing steels - Strand". They refer to 7-wire strands with nominal diameters of 15.2 and 15.7 mm (f pk = N/mm 2 or f pk = N/mm 2 ). As long as EN does not exist, 7-wire strands in accordance with national provisions shall be used. The VSL Multistrand system is able to accommodate bare strands and individually sheathed and greased (protected) monostrands. By varying both the strand diameter and number (and, if applicable, their specified characteristic value of maximum force), it would be possible to obtain a value for the characteristic tensile strength per cable or unit that varies between 260 and kn. All strands of a cable are simultaneously stressed, yet each one is individually locked within a conical anchoring hole by means of wedges. The anchorage function is performed by clamping during strand moving back at the time of pressure release in the jack. The choice of post-tensioning units, as dictated by force requirements, leads for a given strand diameter and characteristic strength to a specific number of strands to be placed. In conjunction with this design element, the choice of type of anchorage associated with the cable depends on the intended function and application of the particular unit. The designation of post-tensioning units is expressed with reference to both the type and number of component strands. The VSL commercial labeling is explained below: The labeling of units or 6S-1 6S-55 signifies: the first digit indicates strand diameter, 6 = 6 1/10" = T mm 6S = 6 1/10" S = T mm (S stands for super). the subsequent digits indicate the number of strands composing the unit. To provide greater detail, the designation of units begins with the names of the anchorages placed at the ends. The following designation serves as an example: Cable VSL E-E 6S-12 L = (1) The functions and names of the anchorages will be defined hereafter. The cable features a length of m and has been stressed at one (1) end. To cover the entire range from 1 to 55 strands, an array of basic anchorages has been developed, i.e.: , thus enabling the creation of any intermediate unit, considering that the number of strands placed may be less than the number of conical holes of the anchorage. In incompletely filled anchor heads, the present strands have to be arranged to centre the applied load to the anchor head.

18 Annex 1 of the European Technical Approval No ETA-06/ CHARACTERISTICS OF SYSTEM UNITS On the basis of the strand characteristics defined in draft Standard "pr EN : Prestressing steels - Part 3: Strand", the values of tendon cross-sections A p, maximum forces under anchorage upon tensioning recommended by EN : P max = min {k 1.A p.f pk ; k 2.A p.f p0.1k }, with k 1 = 0.8, k 2 = 0.9, f pk = N/mm 2, f p0.1k = 0.88 f pk, of VSL post-tensioning units are as follows : Number of strands in the prestressing unit A p STRAND T15.2 or 6 f pk = N/mm 2 F pk = 260 kn F p0.1k = 229 kn A p.f pk 0.8 A p.f pk A p.f p0.1k 0.9 A p.f p0.1k A p STRAND T15.7 or 6S f pk = N/mm 2 F pk = 279 kn F p0.1k = 246 kn A p.f pk 0.8 A p.f pk A p.f p0.1k 0.9 A p.f p0.1k mm² kn kn kn kn mm² kn kn kn kn Note : prestressing force applied to structure must be in accordance with national regulations.

19 Annex 1 of the European Technical Approval No ETA-06/ Temporary overstressing is permitted in accordance with the requirements of EN to a maximum force of k 3.A p.f p0.1k, with k 3 = The system can obviously be used with strands displaying a specific characteristic tensile strength of less than that proposed in the table as strands with f pk = N/mm 2. The provisions for tendons with strands with a characteristic tensile strength f pk = N/mm 2 also apply to tendons with strands with f pk < N/mm 2. The draft Standard pr EN sets the following criteria for the other useful characteristics of prestressing strands composing the VSL units: - Elongation at maximal force: 3.5% - Relaxation at 0.70 f pk after 1,000 hours: 2.5% - Relaxation at 0.80 f pk after 1,000 hours: 4.5% - Fatigue behavior (0.70 f pk ; 190 N/mm 2 ): 2x10 6 cycles - Maximum D value of deflected tensile test: 28% - Modulus of elasticity E p : N/mm 2 Even though the modulus of elasticity of both the tendon or bundle of strands and the (single) strand are somewhat different, VSL still recommends adopting, for the cable calculations, the measured strand value that had been transmitted upon delivery of the supply of strands. Individually greased and sheathed monostrands have the same mechanical properties as listed above for bare strands. 1.3 ANCHORAGES PRESENTATION OF THE ANCHORAGES The VSL Multistrand System anchorages may, depending on their function and commercial labeling, be classified as one of the following: Type "E", "CS", "GC", "NC" and "NC-U" active end anchorages These active anchorages are designed to anchor the tendons at the end through which stressing of the entire set of bundled strands will be carried out. They are composed of an anchor head (cylindrical for the "E" anchor head or a cylindrical / hexagonal-base prism for the "CS" anchor head) drilled with the same number of conically-shaped holes as strands to be anchored; the anchoring step is performed at each strand using wedges inside the conical holes to provide a strong grip. The anchor head is supported by the concrete via an "E", "CS", "GC", "NC" or "NC-U" type anchor plate connected to an "E", "CS", "GC" type trumpet housing deviating the strands to the current duct. The "NC" and "NC-U" anchor plate comprises its own deviating trumpet (ditto for smallest "GC" anchor plates). Type "E", "CS", "GC", "NC" and "NC-U" passive end anchorages These passive anchorages serve to block the tendons at the end on which no stressing force is to be exerted. The "E", "CS", "GC", "NC" and "NC-U" category only includes those anchorages that remain accessible at the time of stressing. These anchorages, which feature pre-clamped wedges and which may be controlled during stressing, are used for this purpose. Type "H" bonded anchorages These dead end anchorages rely, at least in part, on bond in order to maintain the tendon extremity fastened with respect to the concrete. In type "H" anchorages, the clean strands exhibit wires, over a given bond length, folded at their extremities to form an onion. Type "K" fixed couplers These anchorages ensure the continuity of two tendons placed in tension one after the other when two distinct phases of the construction job overlap and the first phase cable is stressed before stressing the second phase cable. Within "K" type fixed couplers, the first-phase cable is anchored on the coupler side with a type "E", "CS" or "GC" anchor (transfer) plate whose head labeled "K" contains the housing units for the coupling elements around its periphery. The second phase cable, on the coupler side, is anchored by means of compression fittings on the strands placed into the aforementioned housings. The two coupled tendons must be units of the same number of strands and the force in the second phase cable shall not be larger than the force in the first phase cable.

20 Annex 1 of the European Technical Approval No ETA-06/ The coupling is then insulated from the concrete by means of a sleeve. Type "V" movable couplers These anchorages ensure the continuity of two lengths of a tendon which are stressed simultaneously. Within "V" type mobile couplers the "movable" head labeled "K" described here before coupling the two lengths is mobile in its sleeve. The coupling head where the opposite strands are locked with compression fittings is equipped with retaining plates. The two coupled lengths must be units of the same number of strands. The coupling is insulated from the concrete by means of the sleeve LIST OF APPROVED ANCHORAGES The set of approved anchorages that allow creating all sorts of intermediate prestressing units have been categorized in the following table: ANCHORAGE Function Active end Passive end Bond Coupler CABLE Unit Label E CS GC NC NC-U E CS GC NC NC-U H K V 1T15.2 / 1T /6S The stressing of tendons at PT system anchorages is only conducted by VSL stressing jacks, which are presented in Chapter CATEGORIES OF USE, POSSIBILITIES AND OPTIONS USES AND OPTIONS OF THE VSL MULTISTRAND SYSTEM VSL Multistrand System units may be: - internal or external (to the concrete or to one another material), - with or without a bonded or unbonded permanent injection, and - applied in structures composed indiscriminately of various construction materials. These units may entail: - an adjustable force, and/or - the potential for replacement provided the absence of bonding with the structure. They can also be conceived for applications that are: - cryogenic, - encapsulated (leak-tight, waterproof), and - electrically isolated (electrical isolation implies a strong waterproofing). Uses Anchorages E CS GC NC NC-U H K V internal* bonded cable with metallic duct internal* bonded cable with plastic duct internal* unbonded E CS GC NC NC-U H K V external* bonded cable external* unbonded cable tendon for use in various material as external cable restressable tendon

21 Annex 1 of the European Technical Approval No ETA-06/ exchangeable tendon cryogenic applications encapsulated tendon (leak tight) electrically isolated tendon (*) of concrete As noted before, - absence of bonding with the structure for exchangeable cable means soft injection or double pipe at anchorage and deviator in case of rigid injection. The clearance between outside diameter of tendon duct and inside diameter of formwork pipe in structure has to be 10 mm minimum. - the VSL Multistrand System may be introduced without grouting, which for example is the case when tendons are left without protection due to their provisional use, or their location within a neutral environment. It goes without saying that all these potential uses and options presume the availability of adequate choices and combinations of all cable components as indicated in this ETA: - for strands see Chapter 2.1 "Strands used", - for ducts see Chapter 2.2 "Ducting", - for anchorages see Chapter 3.4 "Anchorage arrangements", - for injection see Chapter 5.2 "Injection products" POSSIBILITIES OF THE VSL MULTISTRAND SYSTEM The VSL Multistrand System is able to take advantage of the following unique set of possibilities: - Partial stressing or stressing in stages: When prestressing needs to be applied gradually, the stressing may be performed in stages. As the first partial stressing step gets carried out, at the beginning of the second stage, the wedges are unclamped by action of the jack on the cable. Once the targeted force has been reached, pressure in the jack is relaxed and the wedges are once again clamped inside the anchor head. This procedure consists of the same steps as for tensioning of a long cable whose elongation necessitates several successive jack strokes. - Overstressing with shimming: Upon loading of the anchorage during releasing the jack pressure, due to wedges draw in, a simultaneous setting of the strands takes place causing a reduction of elongation and a drop in tension at the cable end. It is still possible however to adjust tension to the desired value by use of a jack chair ring that enables pressing the jack no longer upon the anchor head but rather via jack chair upon the bearing plate. In this case, since the stressing had been conducted under typical conditions and the wedges locked definitively, tensioning is resumed by bringing the head back to the target displacement (the wedge draw in or other value), and then shimming between the anchor head and the anchor plate with split shim (see chapter 2.6.3). - Destressing procedure: The destressing of an anchored cable by a type "E" or "CS" anchor head is possible using a special tooling assembly mounted on the tensioning jack provided that (1) the required strand overlengths have been conserved, (2) that the tendon remains unbonded to the structure. The required strand overlength exceeds the values provided in Chapter 6. From the aforementioned, two zones would appear to stand out, the free length and the anchorage zone; they will be presented in greater detail within the following chapters entitled "Strands and ducts" and "Anchorages".

22 Annex 1 of the European Technical Approval No ETA-06/ CHAPTER 2 STRANDS AND DUCTS 2.1 STRANDS USED The high-strength prestressing steel (strands) composing the tendons are labeled "Y1860S7 No " and are defined in the draft Standard "pr EN : Prestressing steels Part 3: Strand". Alternatively, the strands labeled "Y1770S7 No " may also be employed. The primary characteristics have been recalled in Section 1.2. Monostrands (individually greased and sheathed) can be used for unbonded tendons, either internal or external to concrete or other materials. They are compliant with Annex C.1 of the ETAG 013, which specifies the requirements, verification methods and acceptance criteria of both the grease and the sheathing. 2.2 DUCTING The VSL Multistrand System can use several types of duct as provided in this section. Duct type selection depends on the specific project, the final use designed for the structure and the options selected for the posttensioning units TYPES AND DIMENSIONS OF THE USABLE DUCTS Depending on the specific application, various types of ducts may be employed. From a general standpoint, the ducts used must be mechanically resistant, display continuity in shape, ensure continuity of the seal and, ultimately, continuity in electrical insulation over their entire length, as well as comply with the project's bond requirements while not causing any chemical attack to the prestressing steel. Without claiming to be exhaustive, the following table of frequently-used ducts can be cited as having demonstrated their capacities in the uses and applications associated with the given options: Applications Internal with Cable, bonded in the injection concrete Ducts Corrugated metal duct Metal Ducts Smooth metal duct VSL PT-PLUS Duct Plastic Ducts Smooth plastic duct polyethylene, polypropylene standard NR NR cryogenic NR NR encapsulated NA NR º NR electricallyisolated NA NA º NR with standard + encapsulated NA NR unbonded injection ² electricallyisolated NA NA NR restressable and/or NA NR replaceable External with standard + encapsulated NA ¹ NR Cable, bonded out of injection electricallyisolated NA NA NR the standard + concrete with encapsulated NA ¹ NR (or other unbonded electricallyisolated NA NR³ NR material) injection ² restressable and/or NA ¹ NR replaceable For the other materials such as masonry, wood, etc., refer to conditions relative to concrete and take into account the installation constraints, which may be of various types. Notes: º) This set-up features a fully-bonded cable. ¹) Smooth ducts in polyethylene or polypropylene are the most common. ²) Strands defined in chap. 2.1, i.e. bare strands with total unbonded injection of duct or (individually greased and sheathed) monostrands in rigid filling of duct. ³) Using monostrands. : Advised ~: Possible NR: not recommended NA: not allowed

23 Annex 1 of the European Technical Approval No ETA-06/ The VSL Multistrand System's post-tensioning tendon ducts, for the most part with a circular cross-section, must display an internal diameter large enough to provide for easy strands installation and adequate filling during injection of the protective filling product. With this objective, VSL recommends an internal duct diameter Ø int 1.8 p, where Ap is the nominal crosssection of the strands composing the unit. This relation is suitable for the case of threading the tendons by means of pushing through strand by strand into the ducts installed prior to concreting. In the case of prefabricated cables, it is authorized to adopt a duct with a smaller diameter. Moreover, during the calculations, it is necessary to consider the distance (called eccentricity) existing between the center of the duct and the center of gravity of the strand bundle cross-section. The recommended duct dimensions, along with the corresponding eccentricity values, are given in Chapter 6. The ducts, depending on their type and capacities, may be provided on coil or in straight segments METAL DUCTS The tendons are most often (as per the "STANDARD" solution) isolated from the concrete by means of corrugated steel strip sheaths. According to Standard EN 523, they are either normal (Category 1), i.e. "normal sheaths", or (Category 2), i.e. "rigid sheaths" but bendable by hand, with their characteristics being stipulated in the standard. Connections between coils or straight segments are performed by means of screwing a connector (coupler) onto the two extremities to be connected. The sealing at the joints is done by either an adhesive ribbon or thermo-retractable sleeves. In certain applications (e.g. nuclear, offshore), the tendons are encased in smooth steel ducts. The most frequently-employed tubes, whether welded or not, are thin (in compliance with the EN standards) and machinebendable. The connections between segments are commonly performed by flaring one end and clamping the other; the seal is generated by welding, thermo-retractable sleeves or adhesive ribbon PLASTIC DUCTS S In the case of stringent requirements as regards both corrosion protection and fatigue resistance of cables, it is recommended to use the corrugated plastic duct VSL PT-PLUS. This duct may only be used inside the concrete with a grouting and generates perfect bond between the tendons and the structure. It is recommended for applications submitted to a particularly-aggressive environment or strong fatigue loads. The VSL PT-PLUS duct complies with ETAG 013. The fitting between duct segments is introduced by means of mirror welding or by connectors that provide for both the waterproofing seal and electrical isolation. This duct can be used with all anchorage types E, CS, GC, NC, NC-U, H, K and V. When used with CS-type anchorages, it allows to provide fully-encapsulated units labeled CS "PLUS" as well as electrically isolated units labeled CS "SUPER". Such applications necessitate the presence of rigid half-shells between the duct and its supports at all of the high points along cable path in order to avoid any risk of perforation during stressing of the tendon. Regarding the selection of connection options for VSL PT-PLUS duct, the prescripts in the following table have to be strictly applied. Duct Sizes (1) Radius of curvature (2) Prescribed Connection Type Ø int / Ø ext [m] 23/25 to 100/106 3 Fpk W R (3) Mirror Welding or Connector 115/121 to 150/157 3 Fpk W R << X (3) Mirror Welding 115/121 to 150/157 R > Mirror Welding or Connector Note (1) see Schematic Drawing "Ducting" Note (2) R min see chap Note (3) F pk expressed in MN For design considerations in accordance with EN-1992 where the relative bond properties between reinforcing steel and post-tensioning tendons are relevant it may be assumed that tendons in PT-PLUS plastic ducts have a 50% longer bond length than tendons in corrugated metal ducts. S More common ducts (sleeves or tubes) made of polyethylene or polypropylene can also be used. The connections and seals between the segments are introduced by either mirror welding or electro-weldable couplers, or other means. Plastic pipe in accordance with ETAG 013 / EN-compliant ducts are in fact required.

24 Annex 1 of the European Technical Approval No ETA-06/ With an appropriate set of fittings, they may be used for applications involving encapsulated / waterproof and electrically-isolated tendons ACCESSORIES FOR INLETS, BLEED VENTS AND OUTLETS In internal (concrete) post-tensioning applications for structures composed of prefabricated elements, duct continuity, regardless of duct type, is performed in alignment with the joints by means of a coupler fitting that encompasses a set of rings inserted at the contact element duct end. These plastic accessories serve to complete the seal. Providing permanent protection by means of grout injection presupposes the possibility of intervening anywhere along the cable path in order to adjust the filling and bleed any air, water, etc. that may be within the ducts. In this aim, accessories for re-circulation, venting and bleeding are installed on the ducts. These basically comprise shells or collars fastened onto holes in the ducts and connected to pipes with plugs opening onto an accessible face of the structure. The following options are available: Duct Duct connection accessory Inlet, venting, bleeding or outlet accessory Corrugated steel strip sheath Sealed plastic shell Plastic pipe Smooth steel tube Welded pipes Steel tube or plastic pipe VSL PT-PLUS duct Special "clipped" collar / coupler Plastic pipe Plastic duct Electro-weldable collar or welded pipes Plastic pipe Distributions of inlet, venting, bleeding and outlet points along the cable profile are selected based on a functionspecific study of both the injection pattern and procedure CONNECTION WITH TRUMPETS The strands, located within the ducts, must slightly dilate in the vicinity of the anchorages in order to pass through the corresponding holes in the anchor head. This conical deviation is done in a transition zone called a trumpet and is considered part of the anchorage element. The trumpets of a specific anchor plate are of adequate diameters, with enough length and opening at the end that allows for connection and alignment to the duct of the free length. The seal between the duct and trumpet is carried out using an adhesive strip, a thermo-retractable sleeve or a connector designed as a duct accessory (e.g. a VSL PT-PLUS coupler). 2.3 CABLE LAYOUT The cable layout patterns are not inherent to the VSL Multistrand System, but instead depend on the particular project STRAIGHT LENGTHS BEHIND THE ANCHORAGES In order for the strands not to display excessive deviation with respect to the anchor head support surface, it is recommended to lay out a rectilinear segment in the back of the anchorage. This straight length in axial alignment varies with the size of the prestressing units. The following has been specified as straight length L min which includes both the anchor plate and the trumpet: for F pk < 2 MN L min = 0.8 m for 2 MN W F pk W 7 MN L min = 1.0 m for F pk > 7 MN L min = 1.5 m In the particular case of external PT, refer to chap RADIUS OF CURVATURE In order for the ducts and tendons to be easily installed and handled, for the friction loss values to be respected and for the actions upon deviations to be acceptable, it is recommended to limit the radius of cable curvature.

25 Annex 1 of the European Technical Approval No ETA-06/ For internal (concrete) post-tensioning, in the cases of common deviations, VSL recommends verifying that: R Z 100 Ø int, where R is the radius of curvature and Ø int = internal diameter of the duct. This rule is appropriate for corrugated steel strip sheaths of Category 2 (see Section 2.2.2). When using corrugated steel strip sheaths of Category 1 (Section 2.2.2), the VSL PT-PLUS duct (Section 2.2.3) and smooth steel tube, R Z 3 Fpk, where R is expressed in meters and F pk expressed in MN. In more unique cases involving the use of smooth steel tubes, the radius of curvature may be significantly reduced: R Z 20 Ø int. Under such specific conditions, local concrete strength as well as stresses in strands must be verified. If existing, national provisions may supersede previous recommendations. Tendon sections curved in a U-shape at a tight radius to form an inaccessible end of the tendon named loop anchorage (not considered to be an anchorage in the intent of ETAG 013) respect the following details: - duct in loop is either smooth or corrugated, diameter one size larger than in free length for ease of connection (one fitting into other), - radius of curvature in loop R Z max { 0.6 Fpk ; 0.6 m }, where R is expressed in meters and F pk expressed in MN, - tendon is stressed simultaneously from both ends, - tendon is subject to primarily static load (no significant fatigue load). For external (concrete) post-tensioning, in cases where a high-quality polyethylene tube and thickness adequate for external cable use as defined in Appendix C.2 of the ETAG 013, the following values should be respected. Tendon Unit Minimum Radius in deviation zone between straight lengths Minimum Radius adjacent to the trumpet in anchorage zone [-] [m] [m] While corrugated metal strip sheath can be bent by hand to almost any shape in space, machine-bent smooth steel pipe can only be bent to a constant radius in one plane. The designer should take this into account when specifying the tendon profile SPACING OF THE SUPPORTS AND TOLERANCES The support heights underneath the duct are listed on the cable diagrams approximately every meter for a large radius of curvature and every fifty centimeters for a small radius of curvature, in order to allow for duct placement with the required level of precision. Depending on the type of duct and its dimensions, the fastening fittings are sufficiently robust and close enough such that the ducts and tendons will not exhibit displacements or deformations in excess of the allowed tolerances. Recommended spacing of tendon supports is 10 to 12 time duct diameter. The tolerances on cable positions in the concrete elements must respect the prescriptions stipulated in the draft standard "pr ENV ". Moreover, under all circumstances and in every direction, whenever a cable displays or potentially displays deviation in the vicinity of an edge of concrete which could lead to spalling of concrete cover, an offset with respect to the cable diagram in this direction is only tolerated provided that equilibrium reinforcing bars have been provided over this zone.

26 Annex 1 of the European Technical Approval No ETA-06/ STRAND CUT LENGTH Since the anchorage has been fastened with respect to the structure undergoing post-tensioning, its space consumption is limited to its specific volume. Strand length is strictly the length of the prestressed element between the anchorages increased by the over length crossing the stressing jack(s). These over length have been defined in the drawing for block out dimensions and clearance requirements in Chapter INSTALLATION OF DUCTS AND STRANDS Depending on the size and layout of the worksite, the available space on site and the schedule of works, one of the following solutions is to be adopted (for practical purposes and in order to list all installation possibilities, only the case of an internal post-tensioning of a new concrete structure has been highlighted herein): - Cables (both strands and ducts) fabricated in the plant and then delivered as needed at the worksite for installation into the passive reinforcement; - Strand bundles fabricated in a mobile workshop located adjacent to the worksite and then drawn either before or after concreting into the ducts installed in the passive reinforcement; - Tendons composed by pushing through strand by strand before or after concreting into the ducts installed in the passive reinforcement. 2.5 PROVISIONAL PROTECTION AND LUBRICATION The oiling or greasing of strands, exclusively by means of non-dangerous substances, is performed: - in the aim of providing provisional protection against corrosion from the time of leaving the plant until permanent protection has been achieved (grouting of the cable); - in the aim of lubrication since the friction loss of oiled strands in the ducts during stressing is lower. With this same objective, other products serving to reduce friction loss may be used, as long as they are recognized as non-dangerous, can be easily applied and remain inert in the presence of permanent protection (and the eventual bond to the structure),. It is necessary to point out that: "In addition to the specific clauses relating to dangerous substances contained in this European Technical Approval, there may be other requirements applicable to the products falling within its scope (e.g. transposed European legislation and national laws, regulations and administrative provisions). In order to meet the provisions of the EU Construction Products Directive, these requirements need also to be complied with, when and where they apply." 2.6 CACULATION ELEMENTS FRICTION LOSSES The friction of strands in their ducts, which hinders tendon displacement during stressing, causes a tension loss by friction all along the cable path beginning at the considered live end anchorage. In examining the friction loss formula: f po (x) = f po (0). e - µ ( + k x ), which expresses the tension in a cable at the abscissa x as a function of the tension at the considered active anchorage (positioned at x = 0), where µ is the friction coefficient (over the curve) between the strands and the duct, the sum of the angular deviations of the cable over the distance x, and k the unintentional deviation (per unit length) affecting the cable path, it is recommended to adopt the numerical values of µ and k according to EN They can be summarized as follows: Application µ (rad -1 ) (1) k (rad/m) (2) Internal (concrete) cable with corrugated steel strip sheath Internal (concrete) cable with smooth steel tube Internal (concrete) cable with VSL PT-PLUS duct External (concrete) cable with smooth steel tube

27 Annex 1 of the European Technical Approval No ETA-06/ External (concrete) cable with plastic duct Internal (concrete) cable with individually greased and sheathed strands External (concrete) cable with individually greased and sheathed strands (1) The interval limit values encompass both lubricated and non-lubricated strands. (2) The values of k are zero for cables outside the concrete BASIS FOR EVALUATING ELONGATIONS The calculation of elongations for stressing purposes presumes that the tension curve within the strands along the cable just before locking of the anchorage is known, i.e. f po (x). The measurable elongation upon stressing at the back of the jack for the live end anchorage under consideration, where x = 0, may be written as follows: Elongation of tendon in the stressing jack where, in the second member, - for the 1 st term: L j : length of the strands in the stressing jack. f po (x) ~ (1 + k a ). f po,o = constant Elongation of tendon in the prestressed element Concrete shortening of the prestressed element where f po,o : stress in the strands upon stressing at x = 0, k a : friction loss in the anchorage, which may be neglected for this purpose; Eventual displacement of the dead end of the tendon - for the 2 nd term: La: length of the concerned tendon = length from the live end anchorage to the MIN (f po (x)), i.e. the abscissa of the strands cross-section not moving; - for the 3 rd term: negligible in the majority of cases (except if stresses in the concrete resulting from prestressing are high); - for the 4 th term: in the case where the cable is terminated by a fixed external anchorage whose wedges were manually pre-set (common case), a draw-in g of these so-called wedges on the order of 3 mm must be incorporated. In simplifying and defining: f po,m, the average stress over the concerned strands length, the following is obtained: On the worksite during stressing, elongation due to tendon slack should be eliminated from the reported value with appropriate procedures (e.g. taking into account elongations only once the tendon has been stiffened inside its duct). Note: k a : friction losses in the anchorages are expressed in Section SETTING OF ANCHORAGE WEDGES A 6-mm draw-in of the wedges is considered; this value remains constant for all units and is applicable to all anchorages and all types of wedges. When an adjustment must be conducted, the insertion of a suitable split shim between the anchor head and its anchor plate makes it possible to compensate for the wedge draw-in up to the shim thickness. In this case, the re-tensioning force must not exceed P max, which is the maximum force authorized during unit stressing. If upon initial tensioning P o,o < P max, compensation for the wedge draw-in may thus be complete. If however upon initial tensioning P o,o = P max, an uncompensated wedge draw-in of 1 to 2 mm must be incorporated. The split shim is made of same material as anchor plate E and that diameter of hole is the same as specified in E or CS plate (depending of which anchor is used). Note: compression fittings are without significant setting.

28 Annex 1 of the European Technical Approval No ETA-06/ CHAPTER 3 ANCHORAGES 3.1 DESCRIPTION OF ANCHORAGE COMPONENTS VSL Multistrand System anchorages make use of a set of standard elements, to be categorized as follows: LIVE END / DEAD END ANCHORAGES Live end (active) and dead end (passive) anchorages comprise: - Anchor plates and trumpets: Common anchorage plates and duct-transition trumpets exist in accordance with several models: - the "E" model composed of a simple plate made of steel according to Standard EN The E trumpet is made of steel sheet; - the "CS" model composed of a spheroidal graphite cast iron matrix according to Standard EN 1563, made composite with a very high-strength mortar. The CS trumpet is made of plastic and can be ended by an appropriate ancillary attachment for connection to the VSL PT-PLUS duct. The CS trumpet can also be associated with E anchor plate model. - the "GC" model composed of a lamellar graphite cast iron plate according to Standard EN For small units (3 to 12) the trumpet is comprised in the casting. For greater units, trumpet is made of plastic. - the NC model composed of a spheroidal graphite cast iron body - plate plus trumpet - according to Standard EN The NC-U (1) used with monostrands includes a slightly increased diameter of the transition cone compared to the one of NC used for bare strands. (1) u for unbonded. - Anchor heads: The basic anchor heads may be found in two models: - the "E" model, associated with plate E, GC, NC or NC-U, formed from a steel rod according to Standard EN the "CS" model, associated with plate CS, formed from a steel rod, with quenching and tempering according to Standard EN and then machined or forged to achieve variable thickness. The conical holes are machined on transfer equipment and exhaustively controlled. - Wedges: The wedges are trimmed in alloyed steel for cementation according to Standard EN 10084, then cleaved into parts and finally treated. These elements are available as: the "W6N" or "W6S" model, with two independent parts. The wedges are specified according to two types, adapted to strand diameters, along with the 6N wedges for the 0.6" or T15.2 strands and the 6S wedges for the 0.6"S or T15.7 strands. The S (or super) wedges are differentiated from the N (normal) wedges by the presence on the plane face, which remains apparent, of a grooved trim. These wedges are all submitted to rigorous controls. Both the VSL Multistrand System and VSL Slab System (see Annex 2) wedges are identical. - Protective caps: In order to enable injecting permanent protection and ultimately contributing to protecting the anchorage, three cap models to be used with the plate are available: - the provisional cap designed to contain the injection product for the permanent protection of the zone. Following the curing period, this cap is recycled for reuse; the injection product must be a rigid grout and then the anchorage block-out must be filled with concrete; - the permanent steel cap, containing the anchor head and the protection product, which is left in place after injection; - the permanent plastic cap, containing the anchor head and protection product, which is also to be left in place after injection. This cap has been designed in particular for sealed and electrically isolated cables. Permanent caps are obviously required in all cases calling for the injection of a flexible protection product.

29 Annex 1 of the European Technical Approval No ETA-06/ Provided a few precautions have been taken against corrosion of the metallic parts, the permanent caps may be left apparent; moreover, permanent caps can also be used as temporary caps COUPLERS The couplers rely, for the second phase cable (fixed coupler) or both cable (movable coupler), upon reliable anchorage components that are supported on the installed anchor head including connection grooves. This setup consists of compression fittings, composed of a hard steel wire coil wound in a spiral and a fitting sleeve. The coil is assembled on the strand, and then the fitting sleeve is swaged on the assembled unit PRESENTATION AND PACKING OF ANCHORAGES Given that strand placement only takes place in a rather generalized manner following concreting, the delivery of anchorages on the worksite entails: (only the most common case of internal (concrete) post-tensioning of a new structure will be highlighted herein) 1. Delivery of the anchor plates along with the ducts for placement within the passive reinforcement, and fastening of the plates to the formwork. These anchorage parts are delivered tagged for identification either on pallets or in bulk. Following concreting and curing: 2. Delivery of the anchor heads and wedges along with the strands to be threaded, installation of the anchor heads, stressing and grouting of the permanent cable protection. These anchorage components are delivered tagged for identification, packaged and protected (the same applies for the strands). 3.2 ORGANIZATION OF SUPPLY QUALITY The fabrication of anchorage components of post-tensioning system and especially those designed for the VSL Multistrand System is conducted in compliance with the specifications, production and control procedures laid out in the present ETA and associated documents. The control procedures in effect for anchorage Component Manufacturers, to the same extent as those adopted by the PT Specialist Company, serve to ensure the traceability of the components all the way through to their delivery on site. It is to be recalled that the basis for evaluating these procedures and the supervision of their application have been defined in Chapter 8 and its Annex E of the ETAG 013. It should also be recalled that prior to installation, the compliance of all delivered components, by means of both identification and visual inspection of their state, must be performed by the PT Supervisor. 3.3 INSTALLATION OF VARIOUS ANCHORAGES The installation of VSL units must be assigned to a competent staff member and involve technical management personnel within the PT Specialist Company or a PT Supervisor certified by this company. Anchorage placement in accordance with model prescriptions is handled as follows (for practical purposes, only the most common case of internal (concrete) post-tensioning of a new structure has been highlighted herein): TYPE "E", "CS", "GC", "NC" AND "NC-U" ACTIVE END ANCHORAGES The anchor plates and trumpets are fixed to the formwork and connected to the ducts which have been placed at the time of installation of the passive reinforcement; they are thus incorporated into the structure or structural element upon concreting. It should be noted that for the "E" plates, the possibility exists to install them on a previously-completed concrete facing by means of inserting a flexible and durable joint between the plate and concrete or installing them on a metallic surface. On the other hand, the "CS", "GC", "NC" and "NC-U" plates may only be installed into a concrete block cast around the plates.

30 Annex 1 of the European Technical Approval No ETA-06/ The arrangement of injection holes vary according to the anchorage models and structures and can either open onto the front face or may use pipes in order to open onto other faces of the structure. The anchor heads and wedges are positioned immediately before stressing, a step which serves to avoid polluting the parts. Anchorages used with monostrands (individually greased and sheathed) include sealing between anchor head and monostrands to seal the free grouted tendon length at the anchor plate surface and to confine greased protection in the anchorage zone (e.g. with neoprene disk or plastic sleeve). Initially the monostrands are slightly tensioned to remove slack. Then the free length is filled using cementitions grout to fill the interstices between individual strands and between strands and duct. To achieve this, the duct is sealed on both ends at the anchor plates using temporary formworks which maintain the correct strand pattern and provide a leak tight seal. Once the grout has attained sufficient strength (f cm (t) 20/25 N/mm 2 ), the monostrands are stressed to final force. Anchorages used with both isolating plates (to be inserted between the head and plate) and isolating plastic caps, enable constituting electrically isolated tendons, such as the CS "SUPER" type units. The "E" anchorages can also be used for electrically isolated tendons when using the CS plastic trumpet and isolating plate. As for force losses in the anchorages during stressing, see Section 4.2.1: "Force Measurements" TYPE "E", "CS", "GC", "NC" AND "NC-U" PASSIVE END ANCHORAGES The placement of these anchorages is performed as indicated in Section Once the anchor head has been installed, before stressing at the other end, the wedges are pre-locked using a wedge tool. The anchorage then remains accessible throughout the stressing phase for observation. These anchorages also enable generating electrically isolated tendons TYPE "H" BOND ANCHORAGE The load transfer to the structure is based primarily on the bond of dilated strands within the concrete over a straight segment length and the anchorage by an onion (curvature of wires) at the strand end. Upon exiting the duct, the strands are gradually deviated towards two positioning and maintenance grids. The duct end is reinforced with a ring. The entire anchorage assembly is solidly fastened to the passive reinforcement. Following assembly of the injection tube, the sealing between duct end and strands is ensured by means of resin packing at the level of the ring. The proper working of the anchorage necessitates degreasing the strands on the bond length, along with careful concreting over this length using a concrete whose aggregate diameter does not exceed 30 mm TYPE "K" FIXED COUPLER When a structure must be built in several phases, especially when setting up the scaffolding and formwork over the entire length of the structure proves impossible, it may be wise to stress and anchor certain cables over a fraction of their length and then extend them through the use of a coupler. Once the structure has been completed, the coupler may or may not be inside the concrete. Installation of the coupler proceeds for the active part as defined in Section for the "E", "CS" or "GC" type of live end anchorage, with the installed anchor head being the "K" head fitted with grooves for peripheral coupling. For the passive part of the coupling, the installation takes place prior to concreting of the zone; the strands exiting the duct are deviated through a ring towards the "K" head; they are fitted with compression fittings and placed into the designated grooves. A strapping serves to maintain them in position and a trumpet/sleeve (made of either sheet metal or plastic) isolates the coupler from the concrete, thereby making it possible to transmit the prestressing force through the joint. A vent at the apex of the trumpet/sleeve allows for accurate filling during grouting. For the use in electrically isolated tendon, in addition to specific arrangements of Section 3.3.1, the K coupler requires a load distribution plate to be installed between coupling head and isolating plate.

31 Annex 1 of the European Technical Approval No ETA-06/ TYPE "V" MOVABLE COUPLER When a cable must be composed of several lengths, the "K" head defined in Section is used as movable coupler (of two lengths) in the sleeve. The size of the sleeve is defined to allow free movement of the coupler head during stressing. A vent at the apex of the sleeve allows for accurate filling during grouting. 3.4 ANCHORAGE ARRANGEMENTS According to categories of use, referring to Section 1.4.1, arrangements of anchorage components are described in the following table: Uses Anchorages Components internal bonded cable with metal duct internal bonded cable with plastic duct internal unbonded external bonded cable external unbonded cable tendon for various material (ext. cable) restressable tendon Cryogenic applications exchangeable tendon encapsulated tendon (leak tight) electrically isolated tendon E Plate E E E E E E E E E E Head E E E E E E E E E CS Trumpet E E E E E E E E E CS(1) Cap T(2) T(2) PM(3) PM(3) PM(3) PM(3) PM(4) PM(4) PM(3) PP CS Plate CS CS CS CS CS CS CS CS CS Head CS CS CS CS CS CS CS CS CS Trumpet CS CS CS CS CS CS CS CS CS(1) Cap T(2) T(2) PP(3) PP(3) PP(3) PP(4) PP(4) PP PP GC Plate GC GC GC GC GC GC GC GC GC Head E E E E E E E E E Trumpet GC GC GC GC GC GC GC GC GC Cap T(2) T(2) PM(3) PM(3) PM(3) PM(4) PM(4) PM(4) PM(3) NC Plate NC NC NC NC NC NC NC NC Head E E E E E E E E Cap T(2) T(2) PM(3) PM(3) PM(3) PM(4) PM(4) PM(3) / Anchorages Components internal bonded cable with metal duct internal bonded cable with plastic duct internal unbonded external bonded cable external unbonded cable tendon for various material (ext. cable) restressable tendon exchangeable tendon encapsulated tendon (leak tight) electrically isolated tendon H H H H K Plate (5) (5) (5) (5) (5) (5) (5) (5) Coupler Head K K K K K K K K Trumpet (5) (5) (5) (5) (5) (5) (5) (5) Trumpet sleeve M(6) M(6) M(6) M(6) M(6) M(6) M(6) P(7) V Coupler Head V V V V V V V Trumpet sleeve M(6) M(6) M(6) M(6) M(6) M(6) M(6) Notes: 1: plus isolating shim in between head or coupler and plate, 2: T (as temporary) Provisional cap, Permanent (P) cap can be used, 3: Permanent Metallic (PM) or Permanent Plastic (PP) cap, 4: Permanent Metallic (PM) or Permanent Plastic (PP) cap, special cap housing to preserve strand over-lengths should be used, 5: See E, CS or GC anchor plate and trumpet of first-phase cable, 6: Metallic (M) sleeve (cap), Plastic (P) sleeve can be used, 7: Plastic (P) sleeve (cap)

32 Annex 1 of the European Technical Approval No ETA-06/ GEOMETRICAL AND MECHANICAL USE CONDITIONS For the seating and installation of anchorages, certain construction-related conditions must be verified CLEARANCE BEHIND STRESSING ANCHORAGES In order to facilitate jack placement and simplify the stressing procedure, a free space must be allocated behind the anchorage. These dimensions are given in the drawing "Block out dimensions for anchorages, Clearance requirements" in Chapter 6. For the use of destressing equipment or overstressing equipment these dimensions must be increased CONCRETE STRENGTH, COVER AND ANCHORAGE SPACING Introducing post-tensioning forces into the structures takes the form, within the anchorage zones, of concentrated forces applied onto the plates. The high stress values encountered underneath the anchor plates necessitate certain construction-related measures. For the concrete structures: - The anchorages must be laid out at a sufficient distance from the nearest edge of the concrete (cover) and respect a spacing between anchorages (centre to centre) that will be specified below. - A local anchorage zone reinforcement must be set up in front of the plates; this local (surrounding anchorage body) zone will be defined in Section The concrete in the vicinity of the plates must be especially homogeneous and display, at the time of stressing, an adequate level of strength. - A general zone (surrounding local zone) must be defined by the project designer and laid out in front of the anchorage plates within the structure, thereby reducing the concentrated forces and distributing them over the concrete cross-section, in compliance with the design rules. As stated above and in considering a maximum prestressing force P (t,x) at the time of stressing (t = 0) (1) at the anchorage, thus called P (0,0) P max, for the normal anchor plates and P (0,0) max = P max, the following are defined: (1) Force in the cable, at the anchorage on the concrete side, before load transfer to anchorage b 0 b 0 and b 0 are the distances between the anchorage axis and the edge of the block tested. The local anchorage zone reinforcement required to prevent bursting and spalling in anchorage zones is determined in relation to a rectangular prism of concrete, known as the primary regularisation prism, located behind each anchorage. The cross section of the prism associated with each anchorage is known as the impact rectangle. The impact rectangle has the same centre and the same axes of symmetry as the anchor plate (which should have two axes of symmetry). The impact rectangle with dimensions X x X has the same area as the block tested A = 4 x b 0 b 0 and the same aspect ratio. X min, rect = 0.85 x 2 b 0 ; X min, rect = 0.85 x 2 b 0 X min and X min taking into account dimensions of local anchorage zone reinforcement are given in the tables in Chapter 6, then ) X X min or X X min [1] and X x X = A = 4 x b 0 b 0 [2] ) It should be noted that application of X min may require adaptation of the local anchorage zone reinforcement in accordance with the applicable Eurocodes and national regulations, see Chapter 3.6. b 0

33 Annex 1 of the European Technical Approval No ETA-06/ Rules for centre distance and edge distances of anchorages: Impact rectangles associated with anchorages located in the same cross section should not overlap. In addition, they should remain inside the concrete. Taking into account the concrete cover, we obtain the distance to edge in the two directions : and Note: 10 mm is the concrete cover in the tested block (except for H anchorage block using 25 mm). For anchorage spacing, refer to equations [1] and [2] Following table gives an overview of the different anchorages and minimum concrete strengths at time of stressing for which anchorage spacing and local anchorage zone reinforcement is detailed in this ETA, Chapter 6. Type f cm(t) [N/mm 2 ] at time of stressing E 23/28 28/35 32/40 36/45 43/53 CS 28/35 GC 25/30 28/35 32/40 36/45 40/50 NC / NC-U 53/64 H 28/35 Anchorage spacing and local anchorage zone reinforcement are given in Chapter 6 (data sheets) f cm (t) given in above table is the minimum concrete strength required at the time of stressing the tendon to the maximum possible stressing force 0.8 x A p x f pk. On site, the mean strength of concrete prisms / cubes tested shall be equal or more than the specified f cm (t) at the time when stressing is performed. It remains possible however to partially stress the tendon. In the case of tensioning to 50% of the maximum value at the anchorage for example, the strength of concrete f cm (t) may be reduced to approximately 2/3 of the values indicated above for total stressing. From a general standpoint for unique cases (e.g. when using materials other than concrete), the project designer will apply the pertinent Eurocodes with P design 1.1 F pk to design anchorage and deviation zones (contact may be made with the VSL organization, which will provide the proper advice as regards experimental work and developments). 3.6 LOCAL ANCHORAGE ZONE REINFORCEMENT As mentioned previously, a local anchorage zone reinforcement must be laid out as specified in chapter 6. In accordance with ETAG013 this assumes the presence of additional general reinforcement of 50 kg/m 3 in the structure. For the "E", "CS", "GC", "NC" and "NC-U" type anchorages, this reinforcement is split between a spiral and orthogonal reinforcement (stirrups). The spiral reinforcement defined on the drawings in Chapter 6 displays a large enough pitch of the thread to allow for adequate concreting of the zone. It is recommended to proceed with this layout as stipulated in the approval whenever both the cover and strength conditions have been minimized. As foreseen by this ETA, the local anchorage zone reinforcement specified in this ETA and confirmed in the load transfer tests, may be modified for a specific project design if required in accordance with national regulations and relevant approval of the local authority and of the ETA holder to provide equivalent performance. In the case of grouped anchorages, it is permitted to combine the reinforcement of the individual anchorages. The chosen combination must conserve the dedicated steel cross-sections in all directions. In the case of a unique arrangement in the vicinity of the plates, it is also possible to replace the spiral with a combination of bars that contain equivalent cross-sections in all directions and that are configured at the same depth with respect to the plate.

34 Annex 1 of the European Technical Approval No ETA-06/ In all cases, the local anchorage zone reinforcement must be complemented by a reinforcement in the general anchorage zone for equilibrium designed by the project designer in accordance with typical design rules. Similarly, in all cases, the contractor responsible for concreting must ensure that the density and layout of reinforcement within the anchorage zone allow for adequate and homogeneous concreting of the entire zone. Similar to every other type of anchorage, VSL type H anchorage requires a local anchorage zone reinforcement split between a spiral and orthogonal reinforcement (stirrups). This reinforcement is defined on the drawing in Chapter 6.

35 Annex 1 of the European Technical Approval No ETA-06/ CHAPTER 4 STRESSING 4.1 STRESSING EQUIPMENT The VSL equipment used for cable stressing is composed primarily of stressing jacks, hydraulic power packs (commonly called pumps) and the associated set of measurement instruments or acquisition system STRESSING JACKS Tendons are stressed by means of VSL stressing jacks. This equipment consists of double acting jacks with a central hole that enables stressing the cable in one or several stages and then, if need be, to de-stress the cable. Their primary characteristics will be defined below. In sequence starting from the anchorage, these jacks are composed of: - 1 nose (chair ring) at the front resting upon the anchor head, - 1 body or cylinder, including a piston with a central hole, resting upon the chair ring, - 1 battery composed of metallic tubes fastened to the inside of the hole that guide strands behind the jack, and - 1 pulling anchor head behind the piston, with a gripper plate for facilitating the procedure of stressing by stages. The ungripping of the jack anchorage is performed automatically. The drawing in Chapter 6 lists the VSL jacks and indicates the clearances to be introduced around the anchorages and at the ends of the post-tensioned structures in order to facilitate installation. For the purpose of implementing all the particularities and options, the VSL stressing equipment comprises a series of modular and compatible accessories; as such, a broad range of tools for these jacks is available by VSL. Included herein would be the jack chair ring, the over-stress chair ring, the de-stress chair ring, etc HYDRAULIC PUMPS The VSL pumps comprise the assembly of hydraulic components including: pumps, distributors, nozzles and safety valves. The pumps are typically driven by electric motors. The pumps themselves have been dimensioned for normal stressing speeds and contain safety measurement devices that depend on the specific application MEASUREMENT INSTRUMENTS AND SYSTEMS The VSL force and elongation measurement instruments or systems serve to control with precision the stressing operation and display the set of results obtained. 4.2 PROCESSES OF STRESSING AND CONTROL PROCEDURE Before proceeding with cable stressing, a certain number of preconditions must be met, in particular: - all pertinent safety rules and recommendations must be fully known; - the force targets along with the corresponding values of elongation; moreover, tolerances must be known by the PT Supervisor, who will have applied any eventual necessary adjustments to these values in order to account for parameters specific to the equipment and anchorages; - the procedure to be adopted in the event of a value beyond the tolerance threshold or any other unanticipated incident must be known; - the order in which the post-tensioning cables are to be stressed must be specified;

36 Annex 1 of the European Technical Approval No ETA-06/ the stressing equipment (including measurement instruments) must comply with guidelines furnished in the present ETA; - the required strength of concrete (or other component material) of both the structure and anchorage zone undergoing stressing must be verified; - the loading and support states of the structure associated with the stressing phase must also be verified; - the over lengths of the strands for stressing must remain perfectly clean. The point should be recalled that during the stressing process, it is strictly forbidden to be positioned behind the jack or within its immediate vicinity. The same precautions must be taken for the area in the back of the deadend external anchorages. One of the VSL system's key characteristics lies in its wedge-locking process. Given that the wedges remain in constant contact with the strands during stressing, the locking operation does not require any accessory device FORCE MEASUREMENTS The measurement of force in the cable, as transformed into pressure measurement in the jack, is generally the assigned objective herein. The pressure existing in the jack chamber is indicated by the manometer installed on the pump, with the eventual possibility of exercising controls on the jack. The manometers used (Accuracy 1%), regularly recalibrated using a scale, feature a guaranteed precision of 1% of their maximum pressure, which tends to lie at 600 bars; these instruments thereby provide a precision of 6 bars over the entire manometer scale. In order to obtain the effective force onto the structure, the force resulting from the manometer reading is corrected for losses inside the jack as well as for losses due to friction of the strands in the anchorage. Losses inside the jacks are identified from intrinsic hardware data. Although they contain an independent pressure term and another closely-proportional term, submitted to the maximum pressure reached upon completion of the stressing operation, the losses inside jacks are solely expressed in proportional terms and vary from 1% to 3%. The losses in active anchorages E, CS, NC, NC-U or K, named k a, are due to friction of the strands deviated on the components and, depending on the specific anchorage, vary between 1% and 2%. For the active anchorages type GC they vary from 2 to 3% ELONGATION MEASUREMENTS The measurement of cable elongation is generally a control measurement that provides information on cable behavior during stressing. As for elongation measurements, an index is installed on the tendons. During stressing, elongations are then deduced from measurements of the displacement of this index. Since the onset of displacements combines the seating of tendons in their ducts with their actual elongation, the elongation during initial displacements is obtained by means of extrapolating the pure elongations occurring subsequently. The various pressure-elongation relations noted during the cable stressing phases are recorded on the stressing data sheets, which are to remain available. Section provides a recap of the elongation evaluation basis used during the stressing operation.

37 Annex 1 of the European Technical Approval No ETA-06/ CHAPTER 5 INJECTION AND SEALING 5.1 GENERAL INFORMATION The nature and composition of injection products for the permanent protection of tendons and anchorages and for their eventual bonding to the structure are not inherent to the prestressing process; instead, they depend on the project and the structure's assigned purpose. The products involved must not be a threat to the hygiene, health and the environment. In addition to the specific clauses relating to dangerous substances contained in this European Technical Approval, there may be other requirements applicable to the products falling within its scope (e.g. transposed European legislation and national laws, regulations and administrative provisions). In order to meet the provisions of the EU Construction Products Directive, these requirements need also to be complied with, when and where they apply. 5.2 INJECTION PRODUCTS The products used for the permanent protection of post-tensioning tendons and anchorages implemented by means of injection may be categorized as follows: PRODUCTS FOR BONDED CABLES When it is sought to bond the tendon to the structure, the products or grouts for bonded injection are with a hydraulic cement base: These products may pertain to common grouts defined in the standard EN 447 or special grouts that make use of performance-enhancing admixtures. In some regions of the EU, unfavorable climatic conditions or other conditions impose the application of special grouts according to ETAG 013. Completion of the tendon envelope at the end of the anchorages may be provided by means of either temporary or permanent grouting caps. The concreting of block out is only strictly necessary when using temporary grouting cap (whether recycled or not). Should the permanent grouting cap be left apparent, the metallic parts must be protected against corrosion, see Section PRODUCTS FOR UNBONDED CABLES When it is not sought to bond the tendon to the structure in order, for example, to be able to maintain the tendon accessible, the unbonded injection products are as follows: - with a grease base, as defined in Annex C.4.1 of the ETAG 013, - with a wax base, as defined in Annex C.4.2 of the ETAG 013. In this case, plugging the tendon envelope at the anchorages is still provided by permanent waterproof injection cap. The concreting of the block-out is not strictly necessary here, see above and Section Those products for bonded or unbonded injection covered by a European Technical Approval may also be employed in accordance with the prescribed set of uses.

38 Annex 1 of the European Technical Approval No ETA-06/ INJECTION EQUIPMENT The injection equipment has been adapted to the specific products to be injected. For the cement-based grouting, the VSL injection equipment is composed for the most part of mixers and pumps integrated into a single device that enables preparing the grout and performing the injection. This equipment makes it possible to allocate with precision the grout components and to obtain a perfectlyhomogeneous mix. The pump installed in the injection equipment has been designed for continuous injection at a grout progression speed of the same order of magnitude regardless of the units used. For current grouted cable, provisional caps seal the anchorages till setting of grouting. For some applications, vacuum pumps that allow for depressurization inside the ducts have been included, thereby facilitating progression of the grouting. For the unbonded products such as grease or petroleum wax, the VSL injection equipment is composed of melting devices or heaters, stirrers and pumps. Depending on the application, these components are either integrated or separated on the worksite in accordance with implementation specifications. 5.4 INJECTION AND CONTROL PROCEDURE Before proceeding with the injection of permanent cable protection, a certain number of conditions must be fulfilled and in particular: - The injection product must comply with the terms of the present ETA and the ETAG 013; - The injection equipment must comply with indications laid out in the present ETA, - The waterproof sealing of the tendon and anchorage envelopes (ducts, fittings, rods and caps) must be verified, - The climatic conditions and temperature of the structure must satisfy use conditions of the injection product. The primary controls conducted during injection consist of verifying the adequate filling of the duct by means of rods, bleed vents and outlets laid out all along the cable path and verifying that the product discharged by the vents or outlets displays the required properties. Grouting procedures and grouting surveillance shall be carried out according to EN 446. As an initial approach, the injection product quantities per unit cable length will be derived from: [(internal duct section area - tendon section area) (unit length)] (1 + ), where is such that: in order to consider worksite losses, the shape of the duct and eventual corrugations. The various phases and parameters associated with cable injection are to be recorded on the injection data sheets, which are to remain available. 5.5 SEALING The continuity of protection against all types of aggressions must be ensured all along the cable up to and including the anchorages. The protection measures introduced for this unique zone, which is often located at the extremity of the structure and submitted to external aggressions determined during the design phase, must be effective. Refer to the section entitled "Protective Caps" in Section "Active end / Passive end anchorages" and to the corresponding drawings in Chapter 6. The concreting of block-out in the anchorage zone with surface treatment and eventual reinforcing bars represents the most widespread solution. Moreover, it may be advantageously complemented by a waterproof lining that prevents against all risks of infiltration of fluids that may runoff on the face of the block-out. The permanent metallic caps (if protected by means of galvanization, paint, etc.) or plastic caps may be left apparent.

39 Annex 1 of the European Technical Approval No ETA-06/ CHAPTER 6 SCHEMATIC DRAWINGS (dimensions expressed in mm) Title Page STANDARD ANCHORAGE PARTS : Wedges, Compression fitting 27 Anchor heads Type "E" 28 Anchor heads Type "CS" 29 Protective caps for anchorages 30 ANCHORAGES TYPE "E" Categories of use arrangements 31 43/ /45 & 32/ /28 & 28/35 34 Local anchorage zone 43/53 35 Local anchorage zone 36/45 36 Local anchorage zone 32/40 37 Local anchorage zone 28/35 38 Local anchorage zone 23/28 39 ANCHORAGES TYPE "CS" Categories of use arrangements 40 Sizes 41 Local anchorage zone 28/35 42 ANCHORAGES TYPE "GC" Categories of use arrangements 43 Sizes 44 Local anchorage zone 40/50 45 Local anchorage zone 36/45 46 Local anchorage zone 32/40 47 Local anchorage zone 28/35 48 Local anchorage zone 25/30 49 ANCHORAGES TYPE "NC and NC-U" Categories of use arrangements 50 Sizes 51 Local anchorage zone 53/64 52 ANCHORAGES TYPE 28/35 Sizes and local anchorage zone reinforcement 53 Arrangement and minimum dimensions of concrete sections 54 COUPLERS TYPE "K" Categories of use arrangements 55 Sizes 56 COUPLERS TYPE "V" Categories of use arrangements - Sizes 57 BLOCK OUT DIMENSIONS - CLEARANCE REQUIREMENTS 58 DUCTING 59

40 Annex 1 of the European Technical Approval No ETA-06/ STANDARD ANCHORAGE PARTS WEDGES Wedge W6N Wedge W6S COMPRESSION FITTINGS Fitting Insert CF6 Insert CF6N Assembly

41 Annex 1 of the European Technical Approval No ETA-06/ STANDARD ANCHORAGE PARTS ANCHOR HEADS TYPE E Hole detail Hole spacing E 6-1 E 6-2 E 6-3 E 6-4 E 6-7 E 6-12 E 6-15 E 6-19 E 6-22 E 6-27 E 6-31 E 6-37 E 6-43 E 6-55 Cross section E 6-1 to E 6-55 For sizes ØD and E see ANCHORAGES TYPE E SIZES

42 Annex 1 of the European Technical Approval No ETA-06/ STANDARD ANCHORAGE PARTS ANCHOR HEADS TYPE CS Hole detail Hole spacing STANDARD, PLUS, SUPER & EXTERNAL Optional for STANDARD, PLUS & EXTERNAL 6-7 to 6-37 STANDARD, PLUS & EXTERNAL SUPER For sizes ØD and E see ANCHORAGES TYPE CS SIZES

43 Annex 1 of the European Technical Approval No ETA-06/ STANDARD ANCHORAGE PARTS PROTECTIVE CAPS FOR ANCHORAGES Permanent steel caps for anchorage type GC, E, NC, NC-U Permanent plastic caps for anchorage type CS Unit D Unit D

44 Annex 1 of the European Technical Approval No ETA-06/ ANCHORAGES TYPE E CATEGORIES OF USE ARRANGEMENTS Anchorage cast in concrete structure Anchorage placed against concrete structure Anchorage inserted in masonry structure Anchorage placed against steel structure Anchorage placed against wood structure

45 Annex 1 of the European Technical Approval No ETA-06/ ANCHORAGES TYPE 43/53 MPa SIZES Unit A ØC ØD E F G ØH ØI J (1) K /25 78 Ø / Ø / M / M / M / M / M / M / M / M / M / M / M / M20 All dimensions in [mm] (1) J spacing of holes for fixation to formwork

46 Annex 1 of the European Technical Approval No ETA-06/ ANCHORAGES TYPE 36/45 AND 32/40MPa SIZES Unit A ØC ØD E F G ØH ØI J (1) K /25 79 Ø / Ø / M / M / M / M / M / M / M / M / M / M / M / M20 All dimensions in [mm] (1) J spacing of holes for fixation to formwork

47 Annex 1 of the European Technical Approval No ETA-06/ ANCHORAGES TYPE 28/35 AND 23/28MPa SIZES Unit A ØC ØD E F G ØH ØI J (1) K /25 86 Ø / Ø / M / M / M / M / M / M / M / M / M / M / M / M20 All dimensions in [mm] (1) J spacing of holes for fixation to formwork

48 Annex 1 of the European Technical Approval No ETA-06/ ANCHORAGES TYPE 43/53 MPa LOCAL ANCHORAGE ZONE REINFORCEMENT Reinforcement for concrete with fcm (t) < 43/53 N/mm 2 at time of stressing SPIRAL REINFORCEMENT ORTHOGONAL REINF. Unit ØN n (1) P ØQ L ØR r (2) S T X All dimensions- in [mm] Reinforcement steel f yk < 500 N/mm² (1) n Number of turns incl. first and last turn required for anchorage of spiral (2) r Number of reinforcement layers

49 Annex 1 of the European Technical Approval No ETA-06/ ANCHORAGES TYPE 36/45 MPa LOCAL ANCHORAGE ZONE REINFORCEMENT Reinforcement for concrete with fcm (t) < 36/45 N/mm 2 at time of stressing SPIRAL REINFORCEMENT ORTHOGONAL REINF. Unit ØN n (1) P ØQ L ØR r (2) S T X All dimensions- in [mm] Reinforcement steel f yk < 500 N/mm² (1) n Number of turns incl. first and last turn required for anchorage of spiral (2) r Number of reinforcement layers

50 Annex 1 of the European Technical Approval No ETA-06/ ANCHORAGES TYPE 32/40 MPa LOCAL ANCHORAGE ZONE REINFORCEMENT Reinforcement for concrete with fcm (t) < 32/40 N/mm 2 at time of stressing SPIRAL REINFORCEMENT ORTHOGONAL REINF. Unit ØN n (1) P ØQ L ØR r (2) S T X All dimensions- in [mm] Reinforcement steel f yk < 500 N/mm² (1) n Number of turns incl. first and last turn required for anchorage of spiral (2) r Number of reinforcement layers

51 Annex 1 of the European Technical Approval No ETA-06/ ANCHORAGES TYPE 28/35 MPa LOCAL ANCHORAGE ZONE REINFORCEMENT Reinforcement for concrete with fcm (t) < 28/35 N/mm 2 at time of stressing SPIRAL REINFORCEMENT ORTHOGONAL REINF. Unit ØN n (1) P ØQ L ØR r (2) S T X All dimensions in [mm] Reinforcement steel f yk < 500 N/mm² (1) n Number of turns incl. first and last turn required for anchorage of spiral (2) r Number of reinforcement layers

52 Annex 1 of the European Technical Approval No ETA-06/ ANCHORAGES TYPE 23/28 MPa LOCAL ANCHORAGE ZONE REINFORCEMENT Reinforcement for concrete with fcm (t) < 23/28 N/mm 2 at time of stressing All dimensions in [mm] SPIRAL REINFORCEMENT ORTHOGONAL REINF. Unit ØN n (1) P ØQ L ØR r (2) S T Reinforcement steel f yk < 500 N/mm² (1) n Number of turns incl. first and last turn required for anchorage of spiral (2) r Number of reinforcement layers X

53 Annex 1 of the European Technical Approval No ETA-06/ ANCHORAGES TYPE CS CATEGORIES OF USE ARRANGEMENTS Anchorage cast in concrete structure - STANDARD Unit - PLUS Unit (encapsulated) - SUPER Unit (Electrically Isolated Tendon) - External tendon

54 Annex 1 of the European Technical Approval No ETA-06/ ANCHORAGES TYPE CS SIZES Unit ØA B C ØD E F1 (1) F2 (2) G H1 (1) H2 (2) ØJ (3) K M M M M M M M16 All dimensions in [mm] (1) for STANDARD (2) for PLUS or SUPER (3) J spacing of holes for fixation to formwork

55 Annex 1 of the European Technical Approval No ETA-06/ ANCHORAGES TYPE 28/35 MPa LOCAL ANCHORAGE ZONE REINFORCEMENT Reinforcement for concrete with fcm (t) < 28/35 N/mm² when stressing SPIRAL REINFORCEMENT ORTHOGONAL REINF. Unit ØN n (1) P ØQ L ØR r (2) S T X All dimensions in [mm] Reinforcement steel f yk < 500 N/mm². (1) n Number of turns incl. first and last turn required for anchorage of spiral (2) r Number of reinforcement layers

56 Annex 1 of the European Technical Approval No ETA-06/ ANCHORAGES TYPE GC CATEGORIES OF USE ARRANGEMENTS Anchorage cast in concrete structure - STANDARD Unit - PLUS Unit - External Tendon

57 Annex 1 of the European Technical Approval No ETA-06/ ANCHORAGES TYPE GC SIZES Unit A B ØC ØD E F ØH J (1) K (2) M (2) M (2) M (2) M (2) M M M M M M16 (1) J spacing of holes for fixation to formwork (2) These units do not have a trumpet

58 Annex 1 of the European Technical Approval No ETA-06/ ANCHORAGES TYPE 40/50 MPa LOCAL ANCHORAGE ZONE REINFORCEMENT Reinforcement for concrete with fcm (t) < 40/50 N/mm 2 at time of stressing SPIRAL REINFORCEMENT ORTHOGONAL REINF. Unit ØN n (1) P ØQ L ØR r (2) S T X All dimensions- in [mm] Reinforcement steel f yk < 500 N/mm². (1) n Number of turns incl. first and last turn required for anchorage of spiral (2) r Number of reinforcement layers

59 Annex 1 of the European Technical Approval No ETA-06/ ANCHORAGES TYPE 36/45 MPa LOCAL ANCHORAGE ZONE REINFORCEMENT Reinforcement for concrete with fcm (t) < 36/45 N/mm 2 at time of stressing SPIRAL REINFORCEMENT ORTHOGONAL REINF. Unit ØN n (1) P ØQ L ØR r (2) S T X All dimensions in [mm] Reinforcement steel f yk < 500 N/mm². (1) n Number of turns incl. first and last turn required for anchorage of spiral (2) r Number of reinforcement layers

60 Annex 1 of the European Technical Approval No ETA-06/ ANCHORAGES TYPE 32/40 MPa LOCAL ANCHORAGE ZONE REINFORCEMENT Reinforcement for concrete with fcm (t) < 32/40 N/mm 2 at time of stressing SPIRAL REINFORCEMENT ORTHOGONAL REINF. Unit ØN n (1) P ØQ L ØR r (2) S T X All dimensions in [mm] Reinforcement steel f yk < 500 N/mm². (1) n Number of turns incl. first and last turn required for anchorage of spiral (2) r Number of reinforcement layers

61 Annex 1 of the European Technical Approval No ETA-06/ ANCHORAGES TYPE 28/35 MPa LOCAL ANCHORAGE ZONE REINFORCEMENT Reinforcement for concrete with fcm (t) < 28/35 N/mm 2 at time of stressing SPIRAL REINFORCEMENT ORTHOGONAL REINF. Unit ØN n (1) P ØQ L ØR r (2) S T X All dimensions in [mm] Reinforcement steel f yk < 500 N/mm². (1) n Number of turns incl. first and last turn required for anchorage of spiral (2) r Number of reinforcement layers

62 Annex 1 of the European Technical Approval No ETA-06/ ANCHORAGES TYPE 25/30 MPa LOCAL ANCHORAGE ZONE REINFORCEMENT Reinforcement for concrete with fcm (t) < 25/30 N/mm 2 at time of stressing SPIRAL REINFORCEMENT ORTHOGONAL REINF. Unit ØN n (1) P ØQ L ØR r (2) S T X All dimensions in [mm] Reinforcement steel f yk < 500 N/mm². (1) n Number of turns incl. first and last turn required for anchorage of spiral (2) r Number of reinforcement layers

63 Annex 1 of the European Technical Approval No ETA-06/ ANCHORAGES TYPE NC and NC-U CATEGORIES OF USE ARRANGEMENTS Anchorage cast in concrete structure - NC STANDARD Unit (bonded) - NC PLUS Unit (bonded) - NC-U STANDARD Unit (unbonded)

64 Annex 1 of the European Technical Approval No ETA-06/ ANCHORAGES TYPE NC and NC-U SIZES Type Unit A B G ØD E ØH J (1) K NC M16 NC-U M16 All dimensions in [mm] (1) J spacing of holes for fixation to formwork

65 Annex 1 of the European Technical Approval No ETA-06/ ANCHORAGES TYPE NC and 53/64 MPa LOCAL ANCHORAGE ZONE REINFORCEMENT Reinforcement for concrete with fcm (t) < 53/64 N/mm 2 at time of stressing SPIRAL REINFORCEMENT ORTHOGONAL REINF. Unit ØN n (1) P ØQ L ØR r (2) X S T All dimensions in [mm] Reinforcement steel f yk < 500 N/mm². (1) n Number of turns incl. first and last turn required for anchorage of spiral (2) r Number of reinforcement layers

66 Annex 1 of the European Technical Approval No ETA-06/ ANCHORAGES TYPE 28/35 MPa SIZES AND LOCAL ANCHORAGE ZONE REINFORCEMENT Reinforcement for concrete with f cm(t) < 28/35 N/mm² when stressing Unit A B (1) Arrangement 1 Arrangement 2 A B (1) C D D1 ØE ØF ØG ØH / / / / / / / / / / /32 Reinforcement steel f yk < 500 N/mm². (1) Number of strands with length D1

67 Annex 1 of the European Technical Approval No ETA-06/ ANCHORAGES TYPE H ARRANGEMENT AND MINIMUM DIMENSIONS OF CONCRETE SECTIONS

68 Annex 1 of the European Technical Approval No ETA-06/ COUPLERS TYPE K CATEGORIES OF USE ARRANGEMENTS Coupler type K with anchorage type E Coupler type K with anchorage type CS Coupler type K with anchorage type GC

69 Annex 1 of the European Technical Approval No ETA-06/ COUPLERS TYPE K SIZES Unit ØC ØD B F G ØH E All dimensions in [mm]

70 Annex 1 of the European Technical Approval No ETA-06/ COUPLERS TYPE V CATEGORIES OF USE ARRANGEMENTS SIZES Unit C D B F1 F2 G1 G2 H E All dimensions in [mm] s = coupler movement due to stressing

71 Annex 1 of the European Technical Approval No ETA-06/ BLOCK OUT DIMENSIONS CLEARANCE REQUIREMENTS Notes: Unit Jack ZPE A B ØC D E ØF G Weight kg 6-1 ZPE-23FJ ZPE ZPE ZPE ZPE-7A ZPE-12St ZPE ZPE ZPE ZPE-460/ ZPE ZPE-460/ ZPE ZPE-500K ZPE ZPE ZPE ZPE ZPE ZPE ZPE ZPE ZPE ZPE ZPE ZPE ZPE ZPE (2) (2) (2) (1) If a deeper recess > B is required, minimum lateral clearance E applies instead of block out dimension A (2) Dimensions D, G and the weight of stressing jack type ZPE 1350 depend on jack configuration.

72 Annex 1 of the European Technical Approval No ETA-06/ DUCTING Strand No Unit Corrugated Steel Strip Sheath (1) Duct VSL PT-PLUS (2) Smooth Steel Duct (3) Plastic Duct for Bare Strand (4) Plastic Duct for Sheathed Strand (4) Øint / Øext e Øint / Øext e Øext x t Øext x t min Øext x t min / / x x x / x2.0/2.5/ x / x2.0/2.5/ x x / x2.0/2.5/ x x / / / / x2.0/2.5/ x x / / / / / / / / x2.0/ x x / / / / / / / / x3.0/4.0/ x x / / / / / / / / x3.0/4.0/ x / / x / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / x3.0/4.0/ x3.0/4.0/ x3.0/4.0/ x x x x x x3.0/ x x x3.0/4.0/ x x x3.0/ x x 10.8 (1) Exterior Ø of corrugations. Use next larger duct for strong deviation and long cables. The corrugated steel strip sheaths of diameters larger than 130mm follow the design of EN 523 with the same thickness. (2) Exterior Ø of duct. (3) According to standard EN 10255, EN , EN , EN and EN Recommended values. Dimensions might vary depending on project requirements. (4) According to standard EN 12201, material PE 80. Recommended values. Dimensions might vary depending on project requirements.

73 Annex 2 TECHNICAL DATA OF THE VSL SLAB SYSTEM

74 Annex 2 of the European Technical Approval No ETA-06/ TABLE OF CONTENTS Title Page 1. DEFINITION OF THE SYSTEM 1.1 PRINCIPLE OF THE VSL SLAB SYSTEM CHARACTERISTICS OF SYSTEM UNITS ANCHORAGES PRESENTATION OF THE ANCHORAGES LIST OF APPROVED ANCHORAGES 1.4 CATEGORIES OF USE, OPTIONS AND POSSIBILITIES USES AND OPTIONS OF VSL SLAB SYSTEM UNITS POSSIBILITIES OF THE VSL SLAB SYSTEM 2. STRANDS AND DUCTS 2.1 STRANDS USED REQUIREMENTS OF THE UNBONDED SYSTEM DUCTS USED FOR THE BONDED SYSTEM TYPES AND DIMENSIONS OF USABLE DUCTS METAL DUCTS PLASTIC DUCTS ACCESSORIES FOR INLETS, BLEED VENTS AND OUTLETS CONNECTION WITH SLEEVES 2.4 CABLE LAYOUT STRAIGHT LENGTHS BEHIND THE ANCHORAGES RADIUS OF CURVATURE SPACING OF THE SUPPORTS AND TOLERANCES STRAND CUT LENGTH 2.5 INSTALLATION OF DUCTS AND TENDONS PROVISIONAL PROTECTION AND LUBRICATION CALCULATION ELEMENTS FRICTION LOSSES BASIS FOR EVALUATING ELONGATIONS ACTIVE ANCHORAGE SETTINGS 3. ANCHORAGES 3.1 DESCRIPTION OF ANCHORAGE COMPONENTS LIVE-END / DEAD-END ANCHORAGES PRESENTATION AND PACKING OF ANCHORAGES 3.2 ORGANIZATION OF SUPPLY QUALITY INSTALLATION OF VARIOUS ANCHORAGES TYPE "S 6-1", "S 6-1 PLUS" AND "S 6-4" ACTIVE END ANCHORAGES TYPE "S 6-1", "S 6-1 PLUS" AND "S 6-4" PASSIVE END ANCHORAGES TYPE "SF 6-1" AND "SF 6-1 PLUS" EMBEDDED DEAD END ANCHORAGES TYPE "H 6-(1 through 4)" BONDED ANCHORAGES 3.4 ANCHORAGE ARRANGEMENTS GEOMETRICAL AND MECHANICAL USE CONDITIONS CLEARENCE BEHIND ANCHORAGES CONCRETE COVER AND ANCHORAGE SPACING 3.6 LOCAL ANCHORAGE ZONE REINFORCEMENT STRESSING 4.1 STRESSING EQUIPMENT STRESSING JACKS HYDRAULIC PUMPS INSTRUMENTS AND MEASURING SYSTEMS

75 Annex 2 of the European Technical Approval No ETA-06/ PROCESSES OF STRESSING AND CONTROL PROCEDURE FORCE MEASUREMENTS ELONGATION MEASUREMENTS 5. INJECTION AND SEALING 5.1 INJECTION UNBONDED SYSTEM BONDED SYSTEM 5.2 SEALING SCHEMATIC DRAWINGS 22

76 Annex 2 of the European Technical Approval No ETA-06/ CHAPTER 1 1. SYSTEM DEFINITION DEFINITION OF THE SYSTEM 1.1 PRINCIPLE OF THE VSL SLAB SYSTEM The cable or unit of the VSL Slab System is composed of one or several strands made of high-strength steel called a "tendon", along with the associated set of anchorages. In this system, the cable may be not only the unit itself, but also the assembly of several closely spaced parallel units (in general of just one strand). This System has considered two subsystems (to be called systems in the following discussion for the sake of simplicity), i.e.: - "unbonded", using individually greased and plastic sheathed monostrands placed directly in the concrete. The unbonded protection of the tendons serves to make them independent of the structure. Only greased sheathed monostrands will be considered in the ensuing discussion, see Section 2.1; - "bonded", a grouting type of PT that uses bare strands. In this case, the strands are located within a duct that constitutes a cylindrical or flat conduit. The void thus created is then filled with grout according to EN 447 or Annex C4 of ETAG 013 for the purpose of bonding with the structure and inhibiting corrosion. The constituting strands are those defined in the European Standard White Draft pr EN : "Prestressing steels - Strand". They refer to 7-wire strands with nominal diameters of 15.2 and 15.7 mm (f pk = N/mm 2 or f pk = N/mm 2 ), which are identical to those used with the VSL Multistrand system. As long as EN does not exist, 7-wire strands in accordance with national provisions shall be used. By varying both the strand diameter and number (and, if applicable, their specified characteristic value of maximum force), it would be possible to obtain a value for the characteristic tensile strength per cable or per unit that varies between 260 and kn. Each strand, of a cable or unit, is individually stressed and becomes locked within a conical anchoring hole by means of wedges. The anchorage function is performed by clamping during strand moving back at the time of pressure release in the jack. The choice of post-tensioning units, as dictated by force requirements, leads for a given strand diameter and characteristic strength to a specific number of strands to be laid out in accordance with a recommended spacing plan. In conjunction with this design element, the choice of type of anchorage associated with the cable depends on the intended function and application of the particular unit. The system is limited to units of 1 and 4 strands since these units prove appropriate for common slabs and plates. The designation of post-tensioning units is expressed with reference to both the type and number of component strands. The VSL commercial labeling is explained below: The labeling of units or 6S-1 6S-4 signifies: the first digit indicates strand diameter, 6 = 6 1/10" = T mm 6S = 6 1/10" S = T mm (S stands for super). the subsequent digits indicate the number of strands composing the unit. To provide greater detail, the designation of units begins with the names of the anchorages placed at the ends. The following designation serves as an example: Cable VSL S-S 6S-4 L = (2) Cable VSL 4(S-S 6S-1) L = (2) [cable composed of 4 individual but parallel and closely spaced monostrand units] The functions and names of the anchorages will be defined hereafter. The cables feature a length of m and have been stressed at both (2) ends. The VSL Slab System contains 1 and 4 strand units. The intermediately-dimensioned cables of 2 and 3 strands are composed preferentially by means of parallel arrangement of several monostrand units. The prestressing force applied may naturally be fine-tuned to meet the required prestressing force level by adjusting the appropriate spacing between units.

77 Annex 2 of the European Technical Approval No ETA-06/ CHARACTERISTICS OF SYSTEM UNITS On the basis of the strand characteristics defined in draft Standard "pr EN : Prestressing steels - Part 3: Strand", the values of tendon cross-sections A p, maximum forces under anchorage upon tensioning recommended by EC2 : P max = min {k 1.A p.f pk ; k 2.A p.f p0.1k }, with k 1 = 0.8, k 2 = 0.9, f pk = N/mm 2, f p0.1k = 0.88 f pk, of VSL post-tensioning units are as follows : Number of strands in the prestressing unit A p STRAND T15.2 or 6 f pk = N/mm 2 F pk = 260 kn F p0.1k = 229 kn A p.f pk 0.8 A p.f pk A p.f p0.1k 0.9 A p.f p0.1k A p A p.f pk STRAND T15.7 or 6S f pk = N/mm 2 F pk = 279 kn F p0.1k = 246 kn 0.8 A p.f pk A p.f p0.1k 0.9 A p.f p0.1k mm² kn kn kn kn mm² kn kn kn kn Note : prestressing force applied to structure must be in accordance with national regulations The system can obviously be used with strands displaying a specific characteristic tensile strength of less than that proposed in the table as strands with f pk = N/mm 2. The provisions for tendons with strands with a characteristic tensile strength f pk = N/mm 2 also apply to tendons with strands with f pk < N/mm 2. The draft Standard pr EN sets the following criteria for the other useful characteristics of prestressing strands composing the VSL units: - Elongation at maximal force: 3.5% - Relaxation at 0.70 f pk after 1,000 hours: 2.5% - Relaxation at 0.80 f pk after 1,000 hours: 4.5% - Fatigue behaviour (0.70 f pk ; 190 N/mm 2 ): 2x10 6 cycles - Maximum D value of deflected tensile test: 28% - Modulus of elasticity E p : N/mm 2 The strands are stressed individually, the modulus of elasticity of the strand measured and communicated at the time of its supply is to be taken into account for the cable elongation calculations. Individually greased and sheathed monostrands have the same mechanical properties as listed above for bare strands PRESENTATION OF THE ANCHORAGES 1.3 ANCHORAGES The VSL Slab System anchorages are all (with the exception of the type "H" bonded anchorages) available for the two systems of unbonded or bonded tendons. Depending on their function and commercial labeling, the anchorages may be classified as follows: Type "S 6-1", "S 6-1 PLUS" and "S 6-4" active end anchorages These active anchorages have been designed to anchor tendons at the end at which the stressing will be performed strand by strand. They are composed of a single-block anchorage casing drilled with conically-shaped holes (1 or 4) in which the strands are anchored by means of locking through the use of wedges. These anchorages exist in both the unbonded and bonded systems. The continuity of protection and the waterproof sealing between the duct and the anchorage casing are provided by means of a plastic sleeve. In the case of S 6-1 PLUS, a plastic coat covers the external faces of the anchorage casing in continuity of the plastic sleeve. In the unbonded case, a cap is required to close the housing of the wedges after filling with a protective product (identical or compatible with that of the greased and sheathed single strands) by injection. The "S 6-1" and the "S 6-1 PLUS" anchorages can be used as an intermediate anchorage at a construction joint with the strand being continuous through the anchorage and over the entire tendon length to the end anchorage. The tendon is first stressed at the intermediate anchorage at the construction joint. When the entire

78 Annex 2 of the European Technical Approval No ETA-06/ slab is built, the tendon is stressed at the end anchorage and the intermediate anchorage becomes obsolete but remains in place. The remaining wedge bites on the free length are acceptable. Overlapping wedge bites on the strand and angular deviation of the strand before or behind the intermediate anchorage shall however be avoided. Type "S 6-1", "S 6-1 PLUS" and "S 6-4" passive end anchorages These passive anchorages ensure the locking of tendons at the end on which no stressing force is being exerted by means of the jack. These anchorages apply to both the unbonded and bonded systems. This category only includes those anchorages that remain accessible at the time of stressing. The type "S 6-1" or "S 6-1 PLUS" anchorages, whose wedges have been pre-locked and which may be controlled during stressing are used for the given function. The protection of these dead end anchorages is identical to that of the live end anchorages. Type "SF 6-1" and "SF 6-1 PLUS" embedded dead end anchorages These fixed anchorages are incorporated into the concrete of the structure. Only considered as embedded anchorages are those that make use of a direct transfer on the concrete in order to lock the tendon ends. In both the unbonded and bonded systems, the type SF 6-1 or SF 6-1 PLUS anchorages, which have been assembled onto the tendons prior to their installation, are used for the given function. Their wedges are locked into the anchorage bodies S 6-1 or S 6-1 PLUS and maintained using a series of washers and springs supported on the caps screwed at the end, a set-up that provides mechanical protection against any slipping movement. The SF 6-1 and SF 6-1 PLUS anchorages receive the same protection as the live end anchorages. Type "H 6- (1 through 4)" bonded anchorages These fixed anchorages rely, at least in part, on bonding in order to maintain the tendon end fastened with respect to the concrete. They are strictly the same as those of the VSL Multistrand System, which has been detailed in Annex 1. These anchorages may only be used for the bonded system LIST OF APPROVED ANCHORAGES The set of approved anchorages that allow creating all of the intermediate prestressing units have been categorized in the following table: System ANCHORAGE Function CABLE Active end Passive end Embedded dead end Bonded Unit label S S PLUS S S PLUS S S PLUS unbonded 1T15.2 / 1T / 6S-1 4T15.2 / 4T / 6S-4 Unit label Si Si PLUS Si Si PLUS Si Si PLUS H bonded 1T15.2 / 1T / 6S-1 4T15.2 / 4T / 6S-4 The stressing of tendons anchorages is only conducted by VSL stressing jacks, which are presented in Chap CATEGORIES OF USE, OPTIONS AND POSSIBILITIES USES AND OPTIONS OF VSL SLAB SYSTEM UNITS The VSL Slab System units are entirely internal to the concrete; they may be: - either unbonded, i.e. with individually greased and sheathed monostrands, unbonded to the structure, - or bonded, i.e. with "bare" strands placed inside a duct and with permanent grouting, providing bonding to the structure. These units may also be: - replaceable provided the absence of bonding with the structure, - designed to be encapsulated and perfectly waterproof, - designed to be electrically-isolated.

79 Annex 2 of the European Technical Approval No ETA-06/ Uses Anchorages S 6-1 S 6-1 PLUS SF 6-1 SF 6-1 PLUS Si 6-1 Si 6-1 PLUS SFi 6-1 SFi 6-1 PLUS S 6-4 Si 6-4 H 6-1 & 6-4 internal* bonded cable with metallic duct internal* bonded cable with plastic duct internal* unbonded external* bonded cable external* unbonded cable tendon for use in various material as external cable (1) restressable tendon exchangeable tendon (2) encapsulated tendon (leak tight) electrically isolated tendon (*) of concrete (1) the anchorage must be embedded in concrete block. (2) the designer must check feasibility regarding geometrical tendon layout. It goes without saying that the solutions and options implemented presume the availability of adequate choices and combinations of all unit or cable components, as indicated in this ETA: - for strands see Chapter 2.1 "Strands used", - for ducts see Chapters 2.2 "Requirements of the unbonded system" and 2.3 "Ducts used for bonded system", - for anchorages see Chapter 3.4 "Anchorage arrangements", - for injection see Chapter 5.1 "Injection" POSSIBILITIES OF THE VSL SLAB SYSTEM The VSL Slab System is able to take advantage of the following unique set of possibilities: - Partial stressing or stressing in stages: When prestressing needs to be applied gradually, the stressing may be performed in stages. With the first partial stressing step being carried out at the beginning of the second stage, the wedges are unclamped by action of the jack on the strand. Once the targeted force has been reached, pressure in the jack is relaxed and the wedges are once again locked inside the anchorage. This procedure consists of the same steps as for stressing a long cable strand whose elongation necessitates several successive jack strokes. Since the strands have been stressed individually, the procedure may also entail the total stressing of a fraction of the strands. - Destressing procedure: The destressing of a strand(s) anchored by a type "S 6-1", "S 6-1 PLUS" or "S 6-4" anchorage is possible using a special tooling assembly mounted on the stressing jack provided that the required strand over lengths have been conserved and that the strands remain independent of the structure (unbonded). From the aforementioned, two zones appear to stand out, the free length and the anchorage zone; they will be presented in greater detail in the following chapters entitled "Strands and ducts" and "Anchorages".

80 Annex 2 of the European Technical Approval No ETA-06/ CHAPTER 2 STRANDS AND DUCTS 2. TENDONS AND DUCTS 2.1 STRANDS USED The high-strength prestressing steel (strands) composing the tendons are labeled "Y1860S7 No " and are defined in the draft Standard "pr EN : Prestressing steels Part 3: Strand". On an occasional basis, the strands labeled "Y1770S7 No " may also be employed. The primary characteristics have been recalled in Section 1.2. As regards monostrands (individually greased and sheathed) that are used in the unbonded system, they are compliant with Annex C.1 of the ETAG 013, which specifies the requirements, verification methods and acceptance criteria of both the grease and the sheathing. 2.2 REQUIREMENTS OF THE UNBONDED SYSTEM While it is obvious that the individually greased and sheathed monostrand do not necessitate any duct, the cables composed by several parallel monostrands however require assembly by means of regularly-spaced spacers ensuring their respective positions / linear lay out within the group. The connection of the monostrand sheathing with the anchorage is conducted by means of inserting the strands in a sleeve with one inlet for the "S 6-1" and "S 6-1 PLUS" anchorage or a sleeve with 4 inlets for the "S 6-4" anchorage. These connections are made of plastic and provide for a watertight seal with the sheathing. 2.3 DUCTS USED FOR THE BONDED SYSTEM The VSL Slab System can use several types of duct as provided in this section. Duct type selection depends on the specific project, the final use designed for the structure and the options selected for the post-tensioning units. Although the VSL Slab System authorizes the use of cylindrical ducts, the applications targeted with the slabs and plates increasingly rely upon the flat ducts presented below. For cylindrical ducts, for S6-1 / S6-1 Plus the interested reader is advised to consult Annex 1 of this ETA TYPES AND DIMENSIONS OF USABLE DUCTS Depending on the specific application, various types of ducts may be employed. From a general standpoint, the ducts used must be mechanically resistant, display continuity in shape, ensure continuity of the seal over their entire length and comply with the project's bond requirements, while not causing any chemical attack. Without claiming to be exhaustive, the frequently-used ducts of the following table have demonstrated their capacities in the uses and applications cited: Ducts Metal duct Plastic duct Applications Corrugated steel strip flat sheath VSL PT-PLUS Cable inside the concrete with bonded injection standard ~ encapsulated NA ª electrically isolated NA ª Note: ª) This set-up features a fully-bonded cable. : Advised ~ : Possible NA: not allowed

81 Annex 2 of the European Technical Approval No ETA-06/ The VSL Slab System's prestressing tendon ducts, with either a cylindrical cross-section or oblong, must display internal dimensions large enough to provide for easy tendon installation and adequate filling during grouting of the protective product. The small internal dimension of the oblong section is considerably less than two strand diameters in order to ensure that they remain juxtaposed side by side, in the same position all along the tendon. The most common duct sizes are listed on drawing "Ducting" of Chapter METAL DUCTS Tendons are most often isolated from the concrete by means of corrugated steel strip cylindrical or flat sheaths. Although not covered in Standard EN 523, these flat sheaths due to their shapes and dimensions may be qualified as normal (Category 1). Their characteristics are nearly the same as those of the cylindrical sleeve stipulated in the standard. Connections between coils or straight segments are performed by means of a coupler on the two extremities to be connected. The waterproof sealing at the joints is provided by either an adhesive ribbon or thermoretractable sleeves PLASTIC DUCTS In the case of stringent requirements as regards to both corrosion protection and fatigue resistance of cables, it is recommended to use the corrugated plastic VSL PT-PLUS flat or cylindrical duct; this material generates perfect bonding between the tendons and the structure (6-1 round / 6-4 flat see chapter 6). It is the preferred choice for tendons submitted to a particularly-aggressive environment or strong fatigue loads. The fittings between ducts segments are introduced by means of connectors that serve to generate a waterproof sealing. The VSL PT-PLUS duct complies with ETAG 013. The VSL PT-PLUS duct with its set of appropriate fittings is also employed in the case of fully-encapsulated (waterproof) and or electrically isolated cables. This application necessitates the presence of rigid half-shells between the duct and its supports at all the high points along the cable path in order to avoid any risk of perforation during stressing of the tendon. For design considerations in accordance with EN-1992 where the relative bond properties between reinforcing steel and post-tensioning tendons are relevant it may be assumed that tendons in PT-PLUS plastic ducts have a 50% longer bond length than tendons in corrugated metal ducts ACCESSORIES FOR INLETS, BLEED VENTS AND OUTLET Providing permanent protection by means of grout injection presupposes the possibility of intervening anywhere along the cable path in order to adjust the filling and bleed any air, water, etc. that may be within the ducts. In this aim, accessories for inlets, venting and outlets are installed on the ducts. These basically comprise shells or collars fastened onto holes in the ducts and then connected to pipes with plugs opening onto the slab surface or subsurface. Duct Duct connection accessory Inlet, venting, bleeding or outlet accessory Corrugated steel strip sheath Sealed plastic shell Plastic pipe VSL PT-PLUS duct Special "clipped" collar Plastic pipe The distributions of inlet, venting, bleeding and outlet points along the cable profile are selected based on a function-specific study of the cable path CONNECTION WITH SLEEVES The strands, placed within their ducts, must slightly dilate in the vicinity of the "S 6-4" anchorages in order to pass through the corresponding holes in the anchorage body. This "variable oblong"-shaped duct expansion is called a trumpet and is considered part of the anchorage element. The trumpets are fastened to the formwork of appropriate dimensions, with enough length and opening at the end to allow for connection and alignment of the duct of the current zone.

82 Annex 2 of the European Technical Approval No ETA-06/ The sealing between the ends of duct and trumpet is carried out using an adhesive strip, a thermo-retractable sleeve, or a connector designed as a duct accessory (e.g. a VSL PT-PLUS coupler). 2.4 CABLE LAYOUT The cable layout patterns are not inherent to the VSL Slab System, but instead depend on the particular project STRAIGHT LENGTHS BEHIND THE ANCHORAGES In order for the strands not to display excessive deviation with respect to the anchorage support surface, it is recommended to lay out a rectilinear segment in the back of the anchorage. In both systems (unbonded and bonded), whether the systems include an individual sleeve and a shared sleeve, their trumpet length is sufficient as straight length needed behind the anchorage RADIUS OF CURVATURE - unbonded system: The individually greased and sheathed monostrands typically laid out either isolated or flat juxtaposed must satisfy the minimum radius of curvature r min : deviation : r min S 2.50 m, loop anchorage: r min S 0.60 m, the term loop anchorage indicates a zone with strong curvature over which the total deviation is nearly T radians and which is located at approximately mid-length of the cable, with simultaneous stressing at both ends. In the case of an anchorage with several strands, the strands are to be laid out such that the radial force due to deviation of one strand does not harm the adjacent strand. - bonded system: The corrugated steel strip flat sheath is bent by respecting a minimum radius of curvature r min. With the sheath laid out flat (see drawing "Ducting" of Chapter 6), the following dimensions are respected: plane: r min S 6.00 m, tendon curvature in one direction only elevation: r min S 2.50 m. The VSL PT-PLUS flat duct is bent by respecting a minimum radius of curvature r min. With the duct laid out flat, the following dimensions are respected: plane: r min S 6.00 m, tendon curvature in one direction only elevation: r min S 2.50 m. VSL PT-PLUS round duct 22/25 r min S 2.50 m SPACING OF THE SUPPORTS AND TOLERANCES The support heights underneath the cables or ducts are listed on the cable diagrams approximately every meter for a large radius of curvature and every fifty centimeters for a small radius of curvature, in order to allow for cable (or duct) placement with the required level of precision. The cable (or duct) supports are laid out as stipulated in the design that also establishes the order in which the cables (or ducts) are to be installed to ensure installation without "intertwining" in the case of slabs with tendons in both directions. The fastening fittings are sufficiently robust and close enough such that the cables (or ducts) will not exhibit displacements or deformations in excess of the allowed tolerances. The tolerances on cable positions in the concrete elements must respect the prescriptions stipulated in standard "ENV ". Moreover, in every direction, whenever a cable displays or potentially displays deviation in the vicinity of an edge of concrete which could lead to spalling of the concrete cover, an offset with respect to the cable diagram in this direction is only tolerated provided that equilibrium reinforcing bars are provided over this zone. Special attention must be paid to outward pressure due to structural singularities, such as floor openings. The VSL Slab System authorizes the cable installation technique according to the so-called "free path" or "Freie Spanngliedlage" method defined here after. - In slabs with a thickness of not more than 450 mm the tendons can be placed with the method of Freie Spanngliedlage.

83 Annex 2 of the European Technical Approval No ETA-06/ Tendons placed with the method of Freie Spanngliedlage need only a limited number of tendon supports, in general at the low and high points of the tendon profile, however, with limitations on the spacing as stated below. - The maximum spacing of tendon supports is: m between the tendon fixation to the top layers of reinforcement and an adjacent anchorage, m between the tendon fixation to the bottom layers of reinforcement and an adjacent anchorage or the tendon fixation to the top layer of reinforcement. - At the low points and high points of the tendon profile, the tendons have to be fixed to the top and bottom layers of reinforcement, respectively, on least two locations which have a distance of between 0.3 to 1.0 m. The fixation shall ensure a tight fit without damaging the tendon sheathing. The reinforcement layers have to be fixed in accordance with the relevant standards STRAND CUT LENGTH Since the anchorage has been fastened with respect to the part undergoing post-tensioning, its space consumption is limited to its specific volume. Strand length is strictly the length of the prestressed element between the anchorages increased by the over length crossing the stressing jack(s). These over length have been defined in the drawing "Clearance requirements" of Chapter INSTALLATION OF DUCTS AND STRANDS Depending on the size and layout of the worksite, the available space on site and the schedule of works, one of the following solutions is to be adopted: - unbonded system: - cables fabricated in the plant and then delivered as needed to the worksite for installation into the passive reinforcement; - cables fabricated in a mobile workshop on the worksite, all ready to be installed in the passive reinforcement. - bonded system: - cables (both tendons and ducts) fabricated in the plant and then delivered as needed on the worksite for installation into the passive reinforcement; - strand bundle fabricated in a mobile workshop located adjacent to the worksite and then drawn before concreting into the ducts installed in the passive reinforcement; - tendons composed by threading strand by strand before concreting into the ducts installed in the passive reinforcement. 2.6 PROVISIONAL PROTECTION AND LUBRIFICATION In the bonded system, the oiling or greasing of tendons, exclusively by means of non-dangerous substances, is performed: - in the aim of providing provisional protection against corrosion from the time of leaving the plant until permanent protection has been achieved (grouting of the cable); - in the aim of lubrication since the friction loss of oiled strands in the metal ducts during stressing is lower. With this same objective, other products serving to reduce friction may be used, as long as they are recognized as non-dangerous, can be easily applied and remain inert in the presence of permanent protection (and the eventual rigid bond to the structure).. It is necessary to point out that: "In addition to the specific clauses relating to dangerous substances contained in this European Technical Approval, there may be other requirements applicable to the products falling within its scope (e.g. transposed European legislation and national laws, regulations and administrative provisions). In order to meet the provisions of the EU Construction Products Directive, these requirements need also to be complied with, when and where they apply."

84 Annex 2 of the European Technical Approval No ETA-06/ FRICTION LOSSES 2.7 CALCULATION ELEMENTS The friction of strands in their ducts, which hinders tendon displacement during stressing, causes a tensile loss by friction all along the cable path beginning at the considered live-end anchorage. In examining the friction loss formula: f po (x) = f po (0). e - µ ( + k x ), which expresses the tension in a cable at the abscissa x as a function of the tension at the considered live end anchorage (positioned at x = 0), where µ is the coefficient of friction (over the curve) between the strands and the duct, the sum of the angular deviations of the cable over the distance x, and k the unintentional angular deviation (per unit length) affecting the cable path, it is recommended to adopt the numerical values of µ and k prescribed in Eurocode 2 which can be summarized as follows: Application µ (rad -1 ) (1) k (rad/m) Individually greased and sheathed monostrand Cable with corrugated steel strip sheath Cable with VSL PT-PLUS duct (1) The interval limit values encompass both lubricated and non-lubricated strands BASIS FOR EVALUATING ELONGATIONS See Section of Annex 1. Due to the limited clearance inside the duct, effect of strand slack may be neglected. Note : friction losses at anchorages are expressed in Chapter ACTIVE ANCHORAGE SETTINGS The following wedge draw-in values will be applied herein: - 6 mm, which remains constant for all units and is applicable to all types of anchorage using the "6N" or "6S" wedges implemented without activation of the seating ram of the stressing jack (see Section 4.1.1). - 5 mm, which remains constant for all units and applicable to all types of anchorage using the "6N" or "6S" wedges implemented with activation of the seating ram of the stressing jack (see Section 4.1.1). The VSL Slab System anchorages do not allow for any adjustment with shim.

85 Annex 2 of the European Technical Approval No ETA-06/ CHAPTER 3 ANCHORAGES 3.1 DESCRIPTION OF ANCHORAGE COMPONENTS VSL Slab System anchorages make use of a set of standard elements that can be categorized as follows: LIVE END / DEAD END ANCHORAGES For these active/passive anchorages, the anchor head and plate are combined to form a single part, commonly called the anchorage body. The wedges used for both the VSL Slab System and VSL Multistrand System are identical (see Annex 1). These anchorages comprise: - S 6-1 anchorage The anchorage body is molded and cast in spheroidal graphite cast iron in accordance with Standard EN The conically-shaped hole is subject of a rigorous control. The plastic sleeve is screwed onto the anchorage body. In the unbonded case, the end cap is made of plastic or metal material. In the bonded case, a temporary or permanent cap provides for the waterproof seal of the envelope at the anchorage end in order to perform the grouting. - S 6-1 PLUS anchorage The anchorage body is molded and cast in spheroidal graphite cast iron in accordance with Standard EN The conically-shaped hole is subject of a rigorous control. The external plastic coating to isolate metallic anchorage body from concrete is made of polyethylene. The plastic sleeve is securely fastened to the exit of the anchorage body. In the unbonded case, the end cap is made of plastic material. In the bonded case, a temporary or permanent cap provides for the waterproof seal of the envelope at the anchorage end in order to perform the grouting. - S 6-4 anchorage The anchorage body is molded and cast in spheroidal graphite cast iron in accordance with Standard EN 1563; the four conically-shaped holes are rigorously controlled individually. The plastic sleeve of this anchorage is inserted into the concrete and accommodates in an appropriate form the simply-supported anchorage body. In the unbonded case, a permanent cap filled with grease protects the end anchorage. In the bonded case, a provisional or permanent cap provides a waterproof sealing of the envelope at the anchorage end in order to perform the grouting PRESENTATION AND PACKING OF ANCHORAGES The unbonded system: Since the installation of the monostrands and anchorage body for the S 6-1 anchorage or the trumpet for the S 6-4 anchorage is done prior to concreting, the delivery of anchorages to the worksite entails: 1. Delivery of the S 6-1, S 6-1 PLUS anchorages or the S 6-4 trumpets, along with the monostrand coils and the installation accessories for both cable manufacturing and placement in the passive reinforcement. These anchorage components are fixed to the formwork. The anchorage components are delivered already tagged, packaged and protected. After concreting and cure of the concrete, 2. Delivery of the wedges, eventually along with installation of the S 6-4 anchorage units, the stressing operation, cutting of the strand over lengths and permanent protection of the anchorages. These anchorage components are delivered identified, packaged and protected. The bonded system: Given that strand placement takes place before concreting, the delivery of anchorages on the worksite entails:

86 Annex 2 of the European Technical Approval No ETA-06/ (only the most common case of internal (concrete) post-tensioning of a new structure will be highlighted herein) 1. Delivery of the S 6-1, S 6-1 PLUS anchorages or the S 6-4 trumpets, the ducts, the accessories for placement within the passive reinforcement, along with the strands to be threaded. These anchorage parts are fastened to the formwork. The anchorage units come delivered tagged, packaged and protected. Following concreting and curing of the concrete, 2. Delivery of the wedges (eventually the S 6-4 anchorage body), the stressing operation, cutting of the excess lengths and grouting for the permanent protection of both cables and anchorages. These anchorage components are delivered identified, packaged and protected. 3.2 ORGANIZATION OF SUPPLY QUALITY The fabrication of anchorage components of the post-tensioning system and especially those designed for the VSL Slab System is conducted in compliance with the specifications, production and control procedures laid out in the present ETA document and all associated documents. The control procedures in effect for anchorage Component Manufacturers, to the same extent as those adopted by the PT Specialist Company, serve to ensure the traceability of the components all the way through to their delivery on site. It is to be recalled that the basis for evaluating these procedures and the supervision of their application have been defined in Chapter 8 and its Appendix E of the ETAG 013. It should also be recalled that prior to installation, the compliance of all delivered components, by means of both identification and visual inspection of their state, must be performed by the PT Supervisor. 3.3 INSTALLATION OF VARIOUS ANCHORAGES The implementation of VSL units must be assigned to a competent staff member and involve technical management personnel within the PT Specialist Company or a PT Supervisor certified by this company TYPE "S 6-1", "S 6-1 PLUS" AND "S 6-4" ACTIVE END ANCHORAGES The S 6-1 or S 6-1 PLUS anchorage bodies and the S 6-4 trumpets are fixed to the formwork and connected to the monostrands or ducts aligned at the time of their installation, in general during placing of the passive reinforcement, then incorporated therefore to the structure or structural element during concreting. Depending on the type of system (bonded or unbonded), sleeves or trumpets are appropriate. For detail of connections of anchorages with current ducts refer to Chapter 2.2: Requirements of the unbonded system and 2.3: Duct used for the bonded system. The S 6-4 anchorage unit is installed into the trumpet which was placed before concrete pouring. The wedges are placed immediately prior to stressing, which ensures that they are clean for use. For force losses in the anchorages during stressing, see Section 4.2.1: "Force measurements" TYPE "S 6-1", "S 6-1 PLUS" AND "S 6-4" PASSIVE END ANCHORAGES The placement of these passive anchorages is performed as indicated in Section Once the anchorage has been installed, before stressing at the other end, the wedges are pre-locked using a wedge tool. The anchorage then remains accessible throughout the stressing phase for observation TYPE "SF 6-1" AND "SF 6-1 PLUS" EMBEDDED DEAD END ANCHORAGES In both the bonded and unbonded systems, the fixed SF 6-1, SF 6-1 PLUS anchorages are assembled on the strands, then the wedges are pre-locked and verified and, lastly, the ducts and sleeves are connected. The anchorages assembled in this manner are then positioned and inserted into the passive reinforcement.

87 Annex 2 of the European Technical Approval No ETA-06/ TYPE "H 6- (1 through 4)" BONDED ANCHORAGES These fixed anchorages reserved for the bonded system are strictly identical to those of the multistrand system described in Annex ANCHORAGE ARRANGEMENTS According to categories of use, referring to Section 1.4.1, arrangements of anchorage components are described in the following table: Use Anchorage Component internal bonded cable with metal duct internal bonded cable with plastic duct internal unbonded exchangeable tendon encapsulated tendon (leak tight) electrically isolated tendon S & Si 6-1 Body S S S S S S & Si 6-1 PLUS Body S PLUS S PLUS S PLUS S PLUS S PLUS SF & SFi 6-1 Body S S S S SF & SFi 6-1 PLUS Body S PLUS S PLUS S PLUS S PLUS S PLUS S & Si 6-4 Body S S S S S S (1) Sleeve Si Si S S S Si S Si Cap S S S S S SP (2) H 6-1 & H 6-4 H H Note (1): Electrical isolation provided by plastic trumpet (anchor body), 3.5 GEOMETRICAL AND MECHANICAL USE CONDITIONS For the seating and installation of anchorages, certain construction-related conditions must be verified CLEARANCES BEHIND ANCHORAGES In order to facilitate jack placement and simplify the stressing procedure, a free space must be allocated behind the anchorage. These dimensions are given in the drawing "Clearance requirements" in Chapter CONCRETE STRENGTH, COVER AND ANCHORAGE SPACING Introducing post-tensioning forces into the structures takes the form, within the anchorage zones, of concentrated forces applied onto the anchorage bodies. The high stress values encountered underneath the anchorages necessitate certain construction-related measures, i.e.: - The anchorages must be laid out at a sufficient distance from the nearest edge of the concrete (cover) and respect a spacing between anchorages (centre to centre) that will be specified below. - The concrete in the vicinity of the anchorages must be especially homogeneous and display, at the time of stressing, an adequate level of strength. - A general diffusion zone must be designed and prepared in front of the anchorages within the structure, thereby reducing the concentrated forces and distributing them over the concrete cross-section, in compliance with the design rules.

88 Annex 2 of the European Technical Approval No ETA-06/ As stated above and in considering a maximum prestressing force P (t,x) at the time of stressing (t = 0) (0) at the anchorage (x = 0), thus called P (0,0) P max, for the normal anchor plates and P (0,0) max = P max, the following are defined: (0) Force in the cable, at the anchorage on the concrete side, before load transfer to anchorage. b 0 b 0 and b 0 are the distances between the anchorage axis and the edge of the block tested. These values are given in the tables here after. The local anchorage zone reinforcement required to prevent bursting and spalling in anchorage zones is determined in relation to a rectangular prism of concrete, known as the primary regularisation prism, located behind each anchorage. The cross section of the prism associated with each anchorage is known as the impact rectangle. The impact rectangle has the same centre and the same axes of symmetry as the anchor plate (which should have two axes of symmetry). The impact rectangle with dimensions X x X has the same area as the block tested A = 4 x b 0 b 0 and the same aspect ratio. X min, rect = 0.85 x 2 b 0 ; X min, rect = 0.85 x 2 b 0 X min and X min taking into account dimensions of bursting reinforcement are given in the tables here after, then X X min or X X min [1] and X x X = A = 4 x b 0 b 0 [2] It should be noted that application of X min may require adaptation of the local anchorage zone reinforcement in accordance with the applicable Eurocodes and national regulations, see Chapter 3.6. Rules for center distance and edge distances of anchorages: Impact rectangles associated with anchorages located in the same cross section should not overlap. In addition, they should remain inside the concrete. Taking into account the concrete cover, we obtain the distance to edge in the two directions : ' X X + cover-10 mm and +cover 10 mm 2 2 Note: 10 mm is the concrete cover in the tested block. For anchorage spacing, refer to equations [1] and [2] For f cm (t) 16/20 N/mm 2 16/20 N/mm 2 16/20 N/mm 2 Anchorage S 6-1 S 6-1 PLUS S 6-4 u u mm (3) b 0 2b 0 mm (4) X min X min mm (3) Sizes of anchor plate / anchorage body (4) Sizes of test block During cable stressing, the concrete in front of the anchorages must have reached an adequate strength level, i.e. a 100% stressing of P (o,o) max = P max is not permitted if f cm (t) < 16/20 N/mm 2, regardless of the anchorage layout within the concrete element. It remains possible however to partially tension the tendon. b 0

89 Annex 2 of the European Technical Approval No ETA-06/ (0) Force in the cable, at the anchorage on the concrete side, before load transfer to anchorage. In the case of stressing to 50% of the maximum value at the anchorage for example, the characteristic strengths f cm (t) may be reduced to approximately 2/3 of the values indicated above for total stressing. It is to be recalled that for those anchorages relying upon bonding alone, i.e. for type "H" anchorages, concrete strength within the anchorage zone during stressing must be: f cm (t) 28/35 N/mm LOCAL ANCHORAGE ZONE REINFORCEMENT A local anchorage zone reinforcement is required due to application of the concentrated post-tensioning force. In all cases, the general anchorage zone must contain a reinforcement for equilibrium designed by the project designer in accordance with typical design rules (see examples presented in the drawings Page 29 and 30 "Reinforcement of anchorage zones" in Chapter 6). As foreseen by this ETA, the local anchorage zone reinforcement specified in this ETA and confirmed in the load transfer tests, may be modified for a specific project design if required in accordance with national regulations and relevant approval of the local authority and of the ETA holder to provide equivalent performance. The contractor responsible for concreting must ensure that the density and configuration of reinforcement within the diffusion zone allow for adequate and homogeneous concreting of the entire zone.

90 Annex 2 of the European Technical Approval No ETA-06/ CHAPTER 4 STRESSING 4.1 STRESSING EQUIPMENT The VSL equipment used for stressing is primarily composed of stressing jacks, hydraulic power packs (commonly called pumps) and the associated set of measurement instruments or systems STRESSING JACKS The strands are individually stressed by means of VSL stressing jacks, which are available according to two types: - a double acting front-gripping hollow piston jack, - a twin ram double acting jack, with solid pistons laid out on both sides of the strand. This configuration allows for stressing the intermediate anchorages. This equipment enables stressing the strand in one or several stages and then, if need be, to de-stress the strand. Their primary characteristics will be defined below. In sequence starting from the anchorage, these jacks are composed of: - 1 nose (chair ring) at the front resting upon the anchorage body, ultimately associated with a seating ram; - 1 body or cylinder, composed of one or two jacks and resting upon the chair ring, - 1 auxiliary anchorage driven by the piston(s) and laid out as close as possible to the anchorage installed in place in order to limit the over length of the strands. The ungripping of the jack anchorage is performed automatically. List of VSL jacks: Designation DKP 6 ZPE 23 FJ Type 2 // pistons 1 hollow piston Cross section mm x Length mm Weight kg Stroke mm Ram area mm² Maximum pressure bar Maximum force kn Presence of seating ram? No Yes The drawing in Chapter 6 indicates the clearances to be introduced around the anchorages at the ends of the post-tensioned structures in order to facilitate installation HYDRAULIC PUMPS The VSL pumps comprise the assembly of hydraulic components including: pumps, distributors, nozzles and safety valves. The pumps are typically driven by electric motors. The stations themselves have been dimensioned for normal stressing speeds and contain safety measurement devices that depend on the specific application INSTRUMENTS AND MEASURING SYSTEMS The VSL force and elongation measurement instruments or systems serve to control with precision the stressing operation and display the results obtained.

91 Annex 2 of the European Technical Approval No ETA-06/ PROCESSES OF STRESSING AND CONTROL PROCEDURE Before proceeding with cable stressing, a certain number of preconditions must be met, in particular: - all pertinent safety rules and recommendations must be fully known; - the force targets along with the corresponding values of elongation; moreover, tolerances must be known by the PT Supervisor, who will have applied any eventual necessary adjustments to these values in order to account for parameters specific to the equipment; - the order in which the prestressing cables are to be stressed must be specified, and the order in which the strands in the cables are to be stressed with S 6-4 anchorages must be known; - the stressing equipment (including measurement instruments) must comply with guidelines furnished in the present ETA; - the required strength of the concrete of both the structure and anchorage zone undergoing stressing must be verified; - the loading and support states of the structure associated with the stressing phase must also be verified; - the over lengths of the strands to be stressed must remain perfectly clean. It should nonetheless be recalled that during the stressing process, it is strictly forbidden to be positioned behind the jack or within its immediate vicinity. The same precautions must be taken for the area in the back of the accessible dead-end anchorages. Even though the VSL system does not require any locking accessory device, with some jacks, the wedges may be set in order to reduce the setting of anchorage wedges and its influence on the force = f (x) in the strands FORCE MEASUREMENTS The measurement of force in the cable, as transformed into pressure measurement in the jack, is generally the assigned objective herein. The pressure existing in the jack chamber is indicated by the manometer installed on the pump, with eventual control of the jack. The manometers used (Accuracy 1%), regularly recalibrated using a scale, feature a guaranteed precision of 1% of their maximum pressure, which tends to lie at 490 bars; these instruments thereby provide a precision of 5 bars over the entire manometer scale. In order to obtain the effective force on the structure, the force resulting from the manometer reading is to be corrected for losses inside the jack as well as for losses due to friction of the strands in the anchorage. Losses inside the jacks are identified from intrinsic hardware data. Although they contain an independent pressure term and another closely-proportional term, submitted to the maximum pressure reached upon completion of the stressing operation, the losses inside jacks are solely expressed in proportional terms and exhibit the following values: - DKP 6 jack: 3.5% - ZPE 23 FJ jack: 1.5% The losses in active anchorages, named k a, are due to friction of the strands deviated on the component parts and, depending on the specific anchorage, exhibit the following values: - S 6-1 and S 6-1 PLUS anchorages: 0% to 1% - S 6-4 anchorage: 0% to 1% for the two central strands, 2% for the two outside strands ELONGATION MEASUREMENTS The measurement of cable elongation is generally a control measurement that provides information on cable behavior during stressing. As for elongation measurements, an index is installed on the strands. During the stressing operation, elongations are then deduced from measurements of the displacement of this index. Since the onset of displacements combines the seating of tendons in their ducts with their actual elongation, the elongation during initial displacements is obtained by means of extrapolating the linear elastic elongations occurring subsequently. For single strand round ducts and flat ducts this effect may usually be neglected. The various pressure-elongation relations noted during cable stressing are recorded in the stressing data sheets, which are to remain available. Section provides a recap of the elongation evaluation basis used during the stressing operation.

92 Annex 2 of the European Technical Approval No ETA-06/ CHAPTER INJECTION INJECTION AND SEALING 5.1 INJECTION UNBONDED SYSTEM The monostrand (individually greased and sheathed), protected from the factory by grease, obviously does not necessitate any special additional protection. The "S 6-1", "S 6-1 PLUS" and "S 6-4" anchorage units, after stressing and cut-off of the strands, are filled with grease (identical or compatible with that of the monostrand in compliance with the ETAG 013) by means of injection using a pump. Following filling, a cap serves to enclose the strand ends and the wedge housings BONDED SYSTEM - General information: The nature and composition of injection products for the permanent protection of tendons and anchorages and for their bonding to the structure are not inherent to the prestressing process; instead, they depend on the project and the structure's assigned purpose. The products involved must not be a threat to the hygiene, health and the environment. In addition to the specific clauses relating to dangerous substances contained in this European Technical Approval, there may be other requirements applicable to the products falling within its scope (e.g. transposed European legislation and national laws, regulations and administrative provisions) In order to meet the provisions of the EU Construction Products Directive, these requirements need also to be complied with, when and where they apply. The products used for the permanent protection of post-tensioning tendons and anchorages implemented by means of injection may be categorized as follows: Hydraulic cement-based injection grouts are the most commonly employed. These products may pertain to common grouts defined in the standard EN 447 or special grouts that make use of performance-enhancing admixtures. In some regions of the EU, unfavorable climatic conditions impose the application of special grouts according to ETAG 013. Those injection products that have already received a European Technical Approval may also be used in respect of the prescribed set of uses. Completion of the tendon envelope in the anchorage zone is provided during the time of injection by means of either temporary waterproof caps or definitively by permanent caps. - Injection equipment: The set of injection equipment has been adapted to the specific products to be injected. For the cement-based grout, the VSL injection equipment is composed for the most part of mixers and pumps integrated into a single device that enables preparing the grout and performing the injection. This equipment makes it possible to allocate with precision the grout components and to obtain a perfectly-homogeneous mix. The pump with which the equipment is fitted has been designed for continuous injection at an adapted grout progression speed. - Injection procedures: Before proceeding with the injection of a permanent cable protection, a certain number of conditions must be fulfilled and in particular: - The injection product must comply with the terms of the present ETA and the ETAG 013; - The injection equipment must comply with indications laid out in the present ETA,

93 Annex 2 of the European Technical Approval No ETA-06/ The waterproof sealing of the tendon and anchorage envelopes (ducts, fittings, pipes and caps) must be verified, - The climatic conditions and temperature of the structure must satisfy the use conditions of the injection product. The primary controls conducted during injection consist of verifying the adequate filling of the duct by means of inlets, bleed vents and outlets laid out all along the cable path and verifying that the product discharged by the vents or outlets displays the required properties. Grouting procedures and grouting surveillance shall be carried out according to EN 446. As an initial approach, the injection product quantities per unit cable length will be derived from: [(internal duct section area - tendon section area) (unit length)] (1 + ), where is such that: in order to incorporate worksite losses, the shape of the duct and eventual corrugations. The various phases and parameters associated with cable injection are to be recorded on the injection data sheets, which are to remain available. 5.2 SEALING The continuity of protection against all types of aggressions must be ensured all along the cable up to and including the anchorages. The protection measures introduced for this unique zone, which is located at the end of the slab and frequently protected from external aggressions is most often limited in this case to the filling of the block-out with mortar or concrete. In the case of end zones exposed to aggressive environment additional protection measures may be necessary (permanent cap or waterproof lining).

94 Annex 2 of the European Technical Approval No ETA-06/ CHAPTER 6 SCHEMATIC DRAWINGS (dimensions expressed in mm) Title Page STANDARD ANCHORAGE ELEMENTS Wedges see Annex 1 ANCHORAGES Type S 6-1 and Si 6-1 anchorages Principles of both the "unbonded" and "bonded" systems 23 Sizes 24 Type S 6-1 PLUS and Si 6-1 PLUS anchorages Principles of both the "unbonded" and "bonded" systems 25 Sizes 26 Type S 6-4 and Si 6-4 anchorages Principles of both the "unbonded" and "bonded" systems 27 Sizes 28 Type H 6- (1 through 4) anchorages see Annex 1 REINFORCEMENT OF ANCHORAGE ZONES Anchorage S 6-1 and S 6-1 PLUS 29 Anchorage S CLEARANCE REQUIREMENTS 31 DUCTING 32

95 Annex 2 of the European Technical Approval No ETA-06/ PRINCIPLE OF UNBONDED SYSTEM ANCHORAGE S 6-1 Note: the same anchorage body is used for SF 6-1 PRINCIPLE OF BONDED SYSTEM ANCHORAGE Si 6-1 Note: the same anchorage body is used for SFi 6-1

96 Annex 2 of the European Technical Approval No ETA-06/ ANCHORAGES TYPE S 6-1 / Si 6-1 Anchorage body and sleeve Note: anchorage S 6-1 can be used as intermediate, dead end or embedded anchorage (SF 6-1) Placing devices

97 Annex 2 of the European Technical Approval No ETA-06/ PRINCIPLE OF UNBONDED SYSTEM ANCHORAGE S 6-1 PLUS Note: the same anchorage body is used for SF 6-1 PLUS PRINCIPLE OF BONDED SYSTEM ANCHORAGE Si 6-1 PLUS Note: the same anchorage body is used for SFi 6-1 PLUS

98 Annex 2 of the European Technical Approval No ETA-06/ ANCHORAGES TYPE S 6-1 PLUS / Si 6-1 PLUS Anchorage body and sleeve Note: anchorage S 6-1 PLUS can be used as intermediate, dead end or embedded anchorage (SF 6-1 PLUS) Placing devices

99 Annex 2 of the European Technical Approval No ETA-06/ PRINCIPLE OF UNBONDED SYSTEM ANCHORAGE S 6-4 PRINCIPLE OF BONDED SYSTEM ANCHORAGE Si 6-4

100 Annex 2 of the European Technical Approval No ETA-06/ ANCHORAGES TYPE S 6-4 / Si 6-4 Anchorage body and sleeve Placing devices

101 Annex 2 of the European Technical Approval No ETA-06/ REINFORCEMENT OF ANCHORAGE ZONES ANCHORAGE S 6-1 Example of additional reinforcement to combine with main one ANCHORAGE S 6-1 PLUS Example of additional reinforcement to combine with main one Reinforcement steel f yk 500 N/mm 2

102 Annex 2 of the European Technical Approval No ETA-06/ ANCHORAGE S 6-4 Example of additional reinforcement to combine with main one

103 Annex 2 of the European Technical Approval No ETA-06/ CLEARANCE REQUIREMENTS Stressing jack DKP-6 Stressing jack ZPE-23FJ

104 Annex 2 of the European Technical Approval No ETA-06/ DUCTING Bonded Bonded Unbonded Corrugated steel strip sheath VSL PT-PLUS Duct VSL PT-PLUS Duct ext. duct Min / Max a int a int / 20 a ext a ext. 25 A A 31 b int b ext B 21 35

(English language translation, the original version is in French language) SPIT HIT M. Société SPIT Route de Lyon F-26501 BOURG-LES-VALENCE France

(English language translation, the original version is in French language) SPIT HIT M. Société SPIT Route de Lyon F-26501 BOURG-LES-VALENCE France Centre Scientifique et Technique du Bâtiment 84 avenue Jean Jaurès CHAMPS-SUR-MARNE F-77447 Marne-la-Vallée Cedex 2 Tel. : (33) 01 64 68 82 82 Fax : (33) 01 60 05 70 37 Autorisé et notifié conformément

More information

European Technical Approval ETA-09/0169

European Technical Approval ETA-09/0169 UK CARES Pembroke House, 21 Pembroke Road, Sevenoaks, Kent, TN13 1XR, United Kingdom www.ukcares.com MEMBER OF EOTA European Technical Approval ETA-09/0169 Original version in English Trade name: Holder

More information

European Technical Approval ETA-07/0046

European Technical Approval ETA-07/0046 UK CARES Pembroke House, 21 Pembroke Road, Sevenoaks, Kent, TN13 1XR, United Kingdom www.ukcares.com MEMBER OF EOTA European Technical Approval ETA-07/0046 Original version in English Trade name: Macalloy

More information

(English language translation, the original version is in French language) Powers Throughbolt PTB-XL-ETA7-PRO 01/02/2013 31/01/2018.

(English language translation, the original version is in French language) Powers Throughbolt PTB-XL-ETA7-PRO 01/02/2013 31/01/2018. Centre Scientifique et Technique du Bâtiment 84 avenue Jean Jaurès CHAMPS-SUR-MARNE F-77447 Marne-la-Vallée Cedex 2 Tél. : (33) 01 64 68 82 82 Fax : (33) 01 60 05 70 37 Autorisé et notifié conformément

More information

European Technical Approval ETA-12/0500

European Technical Approval ETA-12/0500 ETA-Danmark A/S Kollegievej 6 DK-2920 Charlottenlund Tel. +45 72 24 59 00 Fax +45 72 24 59 04 Internet www.etadanmark.dk Authorised and notified according to Article 10 of the Council Directive 89/106/EEC

More information

Europeiskt Tekniskt Godkännande European Technical Approval

Europeiskt Tekniskt Godkännande European Technical Approval SITAC Box 553 SE 371 23 Karlskrona SWEDEN MEMBER OF EOTA Tfn.: +46-(0)10-516 63 00 Fax: +46-(0)455-206 88 E-mail: info@sitac.se Europeiskt Tekniskt Godkännande European Technical Approval ETA-12/0257 Handelsnamn

More information

European Technical Approval ETA-06/0259

European Technical Approval ETA-06/0259 European Technical Approval ETA-06/0259 - Original version in German language Handelsbezeichnung Trade name Zulassungsinhaber Holder of approval Zulassungsgegenstand und Verwendungszweck Generic type and

More information

European Technical Approval ETA-10/0153

European Technical Approval ETA-10/0153 ETA-Danmark A/S Kollegievej 6 DK-2920 Charlottenlund Tel. +45 72 24 59 00 Fax +45 72 24 59 04 Internet www.etadanmark.dk Authorised and notified according to Article 10 of the Council Directive 89/106/EEC

More information

Page 1 of European Technical Approval ETA-12/0495

Page 1 of European Technical Approval ETA-12/0495 Page 1 of European Technical Approval ETA-12/0495 VTT Expert Services Oy PL 1001 02044 VTT Puh. +358 20 722 4911 Telekopio +358 20 722 7003 Rakennustuotedirektiivin (89/106/EEC) artiklan 10, neuvoston

More information

European Technical Approval ETA-08/0121

European Technical Approval ETA-08/0121 European Technical Approval - Original version in German language Handelsbezeichnung Trade name Zulassungsinhaber Holder of approval Zulassungsgegenstand und Verwendungszweck Generic type and use of construction

More information

(English language translation, the original version is in French language) Hilti HSL-3

(English language translation, the original version is in French language) Hilti HSL-3 Centre Scientifique et Technique du Bâtiment 84 avenue Jean Jaurès Champs sur Marne F-77447 Marne-la-Vallée Cedex 2 Tél. : (33) 01 64 68 82 82 Fax : (33) 01 60 05 70 37 Autorisé et notifié conformément

More information

Europeiskt Tekniskt Godkännande European Technical Approval

Europeiskt Tekniskt Godkännande European Technical Approval SITAC Box 553 SE 371 23 Karlskrona SWEDEN MEMBER OF EOTA Tfn.: +46-(0)10-516 63 00 Fax: +46-(0)455-206 88 E-mail: info@sitac.se Europeiskt Tekniskt Godkännande European Technical Approval Handelsnamn Trade

More information

Technical Application Document. Hilti HIT-RE 500-SD

Technical Application Document. Hilti HIT-RE 500-SD Technical Application Document Technical Evaluation Report 3/10-649 Injection system for rebar connections Hilti HIT-RE 500-SD Subject to European Technical Approval ATE-09/0295 Holder of approval: HILTI

More information

(English language translation, the original version is in French language) RAWL R-HPT

(English language translation, the original version is in French language) RAWL R-HPT Centre Scientifique et Technique du Bâtiment 84 avenue Jean Jaurès CHAMPS-SUR-MARNE F-77447 Marne-la-Vallée Cedex 2 Tél. : (33) 01 64 68 82 82 Fax : (33) 01 60 05 70 37 Autorisé et notifié conformément

More information

European technical approval

European technical approval Authorised and notified according to Article 10 of the Council Directive 89/ 106/EEC of 21 December 1988 on the approximation of laws, regulations and administrative provisions of Member States relating

More information

European Technical Assessment ETA-10/0153 of 10/06/2015

European Technical Assessment ETA-10/0153 of 10/06/2015 ETA-Danmark A/S Göteborg Plads 1 DK-2150 Nordhavn Tel. +45 72 24 59 00 Fax +45 72 24 59 04 Internet ww.etadanmark.dk Authorised and notified according to Article 29 of the Regulation (EU) No 305/2011 of

More information

European Technical Approval ETA- 13/0056

European Technical Approval ETA- 13/0056 Centre Scientifique et Technique du Bâtiment 84 avenue Jean Jaurès CHAMPS-SUR-MARNE F-77447 Marne-la-Vallée Cedex 2 Tél. : (33) 01 64 68 82 82 Fax : (33) 01 60 05 70 37 Autorisé et notifié conformément

More information

European Technical Approval ETA 13/0526

European Technical Approval ETA 13/0526 European Technical Approval ETA 13/0526 Trade Name Holder of the approval Website Generic type and use of construction product DOLCEA i3 PCIM S.A. Rue du Péquet 54 5590 Achene (Ciney) Belgium www.isoproc.eu

More information

European technical approval

European technical approval Authorised and notified according to Article 10 of the Council Directive 89/ 106/EEC of 21 December 1988 on the approximation of laws, regulations and administrative provisions of Member States relating

More information

European Organisation for Technical Approvals

European Organisation for Technical Approvals Warrington Certification Limited, Holmesfield Road, Warrington, WA1 2DS Tel. +44 (0) 1925-646777 Fax +44 (0) 1925-646667 Member of EOTA Authorised and notified according to Article 10 of the Council Directive

More information

Sealfire W1000 Compound. (2 references for the same product) Fire Stopping and Sealing Product: Penetration Seals

Sealfire W1000 Compound. (2 references for the same product) Fire Stopping and Sealing Product: Penetration Seals UL INTERNATIONAL (UK) LTD Wonersh House, Building C, The Guildway, Old Portsmouth Road, Guildford. GU3 1LR. United Kingdom. Phone : +44 1483 302130 Fax : +44 1483 302230 Email : Inform.NB@uk.ul.com Website

More information

(English language translation, the original version is in French language) 01/02/2013 31/01/2018. Plan 1 & 2

(English language translation, the original version is in French language) 01/02/2013 31/01/2018. Plan 1 & 2 Centre Scientifique et Technique du Bâtiment 84 avenue Jean Jaurès CHAMPS-SUR-MARNE F-77447 Marne-la-Vallée Cedex 2 Tél. : (33) 01 64 68 82 82 Fax : (33) 01 60 05 70 37 Autorisé et notifié conformément

More information

Quality Regulations for Profiles

Quality Regulations for Profiles Quality Regulations for Profiles September 2010 Quality Regulations for Profiles Page 2/42 Contents Preface... 4 1. Terms and Definitions... 5 1.1 Third parties... 5 1.2 Independent laboratories... 5 1.3

More information

Page 1 of European Technical Approval ETA-10/0246 Issued on 21.04.2011

Page 1 of European Technical Approval ETA-10/0246 Issued on 21.04.2011 Page 1 of European Technical Approval ETA-10/0246 Issued on 21.04.2011 VTT EXPERT SERVICES Ltd PL 1001 02044 VTT Puh. +358 20 722 4911 Telekopio +358 20 722 6251 Rakennustuotedirektiivin (89/106/EEC) artiklan

More information

European Technical Approval ETA-10/0124

European Technical Approval ETA-10/0124 ETA-Danmark A/S Kollegievej 6 DK-2920 Charlottenlund Tel. +45 72 24 59 00 Fax +45 72 24 59 04 Internet www.etadanmark.dk Authorised and notified according to Article 10 of the Council Directive 89/106/EEC

More information

SPECIAL INSPECTION AND TESTING AGREEMENT INTERNATIONAL BUILDING CODE

SPECIAL INSPECTION AND TESTING AGREEMENT INTERNATIONAL BUILDING CODE Community Development Permit Services SPECIAL INSPECTION AND TESTING AGREEMENT INTERNATIONAL BUILDING CODE PROJECT NAME PROJECT ADDRESS PERMIT NUMBER CITY RECEIVED STAMP AND INITIALS Instructions: BEFORE

More information

PRCP CE. Version 5.0 of 16 June 2013. Date of entry into force: 1 July 2013

PRCP CE. Version 5.0 of 16 June 2013. Date of entry into force: 1 July 2013 npo Founded by SECO and BBRI PARTICULAR RULES FOR THE CERTIFICATION OF PRODUCTS AND PRODUCTION CONTROL SYSTEMS WITHIN DE FRAMEWORK OF THE EUROPEAN CONSTRUCTION PRODUCTS REGULATION N 305/2011 PRCP CE Version

More information

European Technical Approval ETA-04/0013

European Technical Approval ETA-04/0013 ETA-Danmark A/S Kollegievej 6 DK-2920 Charlottenlund Tel. +45 72 24 59 00 Fax +45 72 24 59 04 Internet www.etadanmark.dk Authorised and notified according to Article 10 of the Council Directive 89/106/EEC

More information

FUTURE SLAB. PENETRATIONS and. DEMOLITION of POST-TENSIONED FLOORS

FUTURE SLAB. PENETRATIONS and. DEMOLITION of POST-TENSIONED FLOORS FUTURE SLAB PENETRATIONS and DEMOLITION of POST-TENSIONED FLOORS 1.0 INTRODUCTION Post-tensioned floor slabs in Australia and South East Asia are now universally regarded as the most cost effective form

More information

1.2 Advantages and Types of Prestressing

1.2 Advantages and Types of Prestressing 1.2 Advantages and Types of Prestressing This section covers the following topics. Definitions Advantages of Prestressing Limitations of Prestressing Types of Prestressing 1.2.1 Definitions The terms commonly

More information

(English language translation, the original version is in Czech language) DEWALT PTB-PRO. DeWalt Black-&-Decker Str. 40 65510 Idstein Germany

(English language translation, the original version is in Czech language) DEWALT PTB-PRO. DeWalt Black-&-Decker Str. 40 65510 Idstein Germany TECHNICKÝ A ZKUŠEBNÍ ÚSTAV STAVEBNÍ PRAHA, s.p. Prosecká 811/76a CZ-190 00 Praha 9 Tel.: +420 286 019 458 Internet: www.tzus.cz Authorised and notified according to Article 10 of the Council Directive

More information

PUBLICATIONS. Introduction

PUBLICATIONS. Introduction Page: 1 of 10 Introduction 1. The requirements of this document supplement the Factory Production Control requirements given in Table 1 of PN111 by giving the specific requirements for Factory Production

More information

European Technical Approval ETA 13/0384

European Technical Approval ETA 13/0384 European Technical Approval ETA 13/0384 Trade Name Holder of the approval Website Generic type and use of construction product Isobriq EU, Isobriq LE, Isobriq PA & Isobriq ZE Isobriq sa 49 Rue Slar 4801

More information

Rakennustuotedirektiivin (89/106/EEC) artiklan 10, neuvoston direktiivi 21. joulukuuta 1988, mukaisesti notifioitu tuotehyväksyntälaitos EOTAN JÄSEN

Rakennustuotedirektiivin (89/106/EEC) artiklan 10, neuvoston direktiivi 21. joulukuuta 1988, mukaisesti notifioitu tuotehyväksyntälaitos EOTAN JÄSEN VTT Expert Services Oy PL 1001 02044 VTT Puh. +358 20 722 4911 Telekopio +358 20 722 7003 Rakennustuotedirektiivin (89/106/EEC) artiklan 10, neuvoston direktiivi 21. joulukuuta 1988, mukaisesti notifioitu

More information

European Technical Approval ETA-07/0211

European Technical Approval ETA-07/0211 European Technical Approval ETA-07/0211 - Original version in German language Handelsbezeichnung Trade name Zulassungsinhaber Holder of approval Zulassungsgegenstand und Verwendungszweck Generic type and

More information

Concrete structures for nuclear facilities

Concrete structures for nuclear facilities 22 May 1992 Concrete structures for nuclear facilities 1 General 3 2 Safety analysis report, classification document and quality assurance programmes 3 3 Design documents for concrete structures 4 3.1

More information

Authorised and notified according to Article 10 of the Council Directive 89/106/EEC of 21 December 1988 on the

Authorised and notified according to Article 10 of the Council Directive 89/106/EEC of 21 December 1988 on the ÖSTERREICHISCHES I N S T I T U T F Ü R B A U T E C H N I K A-1010 Vienna, Schenkenstrasse 4 Tel.: + 4 3 ( 0 ) 1-5 3 3 6 5 5 0 Fax: + 4 3 ( 0 ) 1-5 3 3 6 4 2 3 relating to construction products E - m a

More information

Draft Table of Contents. Building Code Requirements for Structural Concrete and Commentary ACI 318-14

Draft Table of Contents. Building Code Requirements for Structural Concrete and Commentary ACI 318-14 Draft Table of Contents Building Code Requirements for Structural Concrete and Commentary ACI 318-14 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE (ACI 318 14) Chapter 1 General 1.1 Scope of ACI 318

More information

Assessment Report Construction Product Regulation* * CPR - REGULATION (EU) No 305/2011

Assessment Report Construction Product Regulation* * CPR - REGULATION (EU) No 305/2011 1. plan 1) Goal: Assessment and verification of the constancy of performance of the products as described by the manufacturer in his Declaration of Performance through: initial inspection of the manufacturing

More information

European technical approval ETA-10/0460

European technical approval ETA-10/0460 - Original version in German language Handelsbezeichnung Trade name fischer termoz LO 8 Zulassungsinhaber Holder of approval Zulassungsgegenstand und Verwendungszweck Generic type and use of construction

More information

European Technical Approval ETA-09/0040

European Technical Approval ETA-09/0040 European Technical Approval ETA-09/0040 - Original version in German language Handelsbezeichnung Trade name Zulassungsinhaber Holder of approval Zulassungsgegenstand und Verwendungszweck Generic type and

More information

SERIES NG 1800 STRUCTURAL STEELWORK

SERIES NG 1800 STRUCTURAL STEELWORK MANUAL OF CONTRACT DOCUMENTS FOR HIGHWAY WORKS VOLUME 2 NOTES FOR GUIDANCE ON THE SPECIFICATION FOR HIGHWAY WORKS SERIES NG 1800 STRUCTURAL STEELWORK Contents Clause Title Page NG 1800 (08/14) General

More information

DOW CORNING SENEFFE (Belgium) DOW CORNING GmbH WIESBADEN (Germany) This version replaces ETA 03/0003 valid from 2008-04-10 until 2013-04-09

DOW CORNING SENEFFE (Belgium) DOW CORNING GmbH WIESBADEN (Germany) This version replaces ETA 03/0003 valid from 2008-04-10 until 2013-04-09 European Technical Approval ETA-03/0003 Trade name: Holder of the approval: Website: Generic type and use of construction product(s): DOW CORNING 3362 AND 3362 HD BLACK GREY WHITE DOW CORNING Parc Industriel

More information

European Technical Approval ETA-01/0013

European Technical Approval ETA-01/0013 European Technical Approval ETA-01/0013 - Original version in German language Handelsbezeichnung Trade name Zulassungsinhaber Holder of approval Zulassungsgegenstand und Verwendungszweck Generic type and

More information

European Technical Assessment ETA-15/0028 of 23/02/2015

European Technical Assessment ETA-15/0028 of 23/02/2015 ETA-Danmark A/S Göteborg Plads 1 DK-2150 Nordhavn Tel. +45 72 24 59 00 Fax +45 72 24 59 04 Internet ww.etadanmark.dk Authorised and notified according to Article 29 of the Regulation (EU) No 305/2011 of

More information

SAFETY FENCES, SAFETY BARRIERS AND PEDESTRIAN GUARDRAILS

SAFETY FENCES, SAFETY BARRIERS AND PEDESTRIAN GUARDRAILS SERIES NG 400 SAFETY FENCES, SAFETY BARRIERS AND PEDESTRIAN GUARDRAILS Contents Clause Title Page NG 401 Performance Criteria for Safety Fences and Safety Barriers 2 NG 402 Components for Safety Fences

More information

REHABILITATION OF THE FIGUEIRA DA FOZ BRIDGE

REHABILITATION OF THE FIGUEIRA DA FOZ BRIDGE REHABILITATION OF THE FIGUEIRA DA FOZ BRIDGE A.Rito Proponte, Lda, Lisbon, Portugal J. Appleton A2P Consult, Lda, Lisbon, Portugal ABSTRACT: The Figueira da Foz Bridge includes a 405 m long cable stayed

More information

METHOD OF STATEMENT FOR STATIC LOADING TEST

METHOD OF STATEMENT FOR STATIC LOADING TEST Compression Test, METHOD OF STATEMENT FOR STATIC LOADING TEST Tension Test and Lateral Test According to the American Standards ASTM D1143 07, ASTM D3689 07, ASTM D3966 07 and Euro Codes EC7 Table of Contents

More information

Installation guide for the SafeLine type anchorage device. Tested in compliance with EN 795: 1996. No.: SE-...

Installation guide for the SafeLine type anchorage device. Tested in compliance with EN 795: 1996. No.: SE-... Installation guide for the SafeLine type anchorage device Tested in compliance with EN 795: 1996 No.: SE-... Version: 09.10.2008 SE 67 Subject to technical alterations! Contents 1. General information

More information

University of Missouri Hospitals and Clinics. Structural Repair and Protection of Post-tensioned Parking Garage

University of Missouri Hospitals and Clinics. Structural Repair and Protection of Post-tensioned Parking Garage University of Missouri Hospitals and Clinics Structural Repair and Protection of Post-tensioned Parking Garage 1 University of Missouri Project The University of Missouri Health Care Patient and Visitor

More information

Eurooppalainen tekninen hyväksyntä ETA-12/0045 European Technical Approval

Eurooppalainen tekninen hyväksyntä ETA-12/0045 European Technical Approval VTT EXPERT SERVICES OY PL 1001 02044 VTT Tel. + 358 20 722 111 www.vttexpertservices.fi Rakennusalan tuotteita koskevan jäsenvaltioiden lainsäädännön lähentämisestä 21 päivänä joulukuuta 1988 annetun neuvoston

More information

DOCUMENT CAESAS/1: SCHEME DESCRIPTION AND BENEFITS

DOCUMENT CAESAS/1: SCHEME DESCRIPTION AND BENEFITS CONFORMITY ASSESSMENT FOR THE EXECUTION OF STEEL & ALUMINIUM STRUCTURES DOCUMENT CAESAS/1: SCHEME DESCRIPTION AND BENEFITS 2nd Edition July 2012 Issued under the authority of the Governing Board for Certification

More information

Eurooppalainen tekninen hyväksyntä ETA 01/0003. Sormat Oy Harjutie 5 FIN 21290 Rusko. Sormat Oy Harjutie 5

Eurooppalainen tekninen hyväksyntä ETA 01/0003. Sormat Oy Harjutie 5 FIN 21290 Rusko. Sormat Oy Harjutie 5 VTT VALTION TEKNILLINEN TUTKIMUSKESKUS PL 1000 (Lämpömiehenkuja 2) 02044 VTT, FINLAND Puh. +358 20 722 4911 Faksi +358 20 722 6251 Rakennustuotedirektiivin (89/106/EEC) artiklan 10, neuvoston direktiivi

More information

European Technical Approval ETA-10/0200

European Technical Approval ETA-10/0200 Deutsches Institut für Bautechnik Anstalt des öffentlichen Rechts Kolonnenstr. 30 B 10829 Berlin Germany Tel.: +49(0)30 787 30 0 Fax: +49(0)30 787 30 320 E-mail: dibt@dibt.de Internet: www.dibt.de Mitglied

More information

Fire Stopping and Sealing Product: Penetration Seals

Fire Stopping and Sealing Product: Penetration Seals UL INTERNATIONAL (UK) LTD Wonersh House, Building C, The Guildway, Old Portsmouth Road, Guildford. GU3 1LR. United Kingdom. Phone : +44 1483 302130 Fax : +44 1483 302230 Email : Inform.NB@uk.ul.com Website

More information

European Technical Approval ETA-09/0296

European Technical Approval ETA-09/0296 Deutsches Institut für Bautechnik Anstalt des öffentlichen Rechts Kolonnenstr. 30 L 10829 Berlin Germany Tel.: +49(0)30 787 30 0 Fax: +49(0)30 787 30 320 E-mail: dibt@dibt.de Internet: www.dibt.de Mitglied

More information

Guidance on the In Vitro Diagnostic Medical Devices Directive 98/79/EC

Guidance on the In Vitro Diagnostic Medical Devices Directive 98/79/EC Guidance on the In Vitro Diagnostic Medical Devices Directive 98/79/EC August 2013 Contents 1 Introduction...3 2 Scope of the directive...3 2.1 What is an in vitro diagnostic medical device?... 3 2.2 Specimen

More information

Scheme rules for thermal insulation products for building equipment and industrial installations - VDI certification scheme

Scheme rules for thermal insulation products for building equipment and industrial installations - VDI certification scheme Scheme rules for thermal insulation products for building equipment and industrial installations - certification scheme April 6, 2011 1. Introduction This document presents the rules of the product certification

More information

European technical approval

European technical approval Authorised and notified according to Article 10 of the Council Directive 89/ 106/EEC of 21 December 1988 on the approximation of laws, regulations and administrative provisions of Member States relating

More information

Page 1 of European Technical Approval ETA-08/0018

Page 1 of European Technical Approval ETA-08/0018 Page 1 of European Technical Approval ETA-08/0018 VTT Expert Services Oy PL 1001 02044 VTT Puh. +358 20 722 4911 Telekopio +358 20 722 7003 Rakennustuotedirektiivin (89/106/EEC) artiklan 10, neuvoston

More information

Eurooppalainen tekninen hyväksyntä ETA 08/0173 European Technical Approval. Sormat S KA kiila ankkurit Sormat through bolt S KA

Eurooppalainen tekninen hyväksyntä ETA 08/0173 European Technical Approval. Sormat S KA kiila ankkurit Sormat through bolt S KA VTT VALTION TEKNILINEN TUTKIMUSKESKUS PL 1000 (Kemistintie 3) 02044 VTT Puh. + 358 20 722 4911 Telekopio +358 20 722 6251 Rakennustuotedirektiivin (89/106/EEC) artiklan 10, neuvoston direktiivi 21. joulukuuta

More information

PRESTRESSED CONCRETE. Introduction REINFORCED CONCRETE CHAPTER SPRING 2004. Reinforced Concrete Design. Fifth Edition. By Dr. Ibrahim.

PRESTRESSED CONCRETE. Introduction REINFORCED CONCRETE CHAPTER SPRING 2004. Reinforced Concrete Design. Fifth Edition. By Dr. Ibrahim. CHAPTER REINFORCED CONCRETE Reinforced Concrete Design A Fundamental Approach - Fifth Edition Fifth Edition PRESTRESSED CONCRETE A. J. Clark School of Engineering Department of Civil and Environmental

More information

Page 1 of European Technical Approval ETA-09/0129, Issued on September 26, 2011, valid until June 3, 2014

Page 1 of European Technical Approval ETA-09/0129, Issued on September 26, 2011, valid until June 3, 2014 Page 1 of European Technical Approval ETA-09/0129, Issued on September 26, 2011, valid until June 3, 2014 VTT Expert Services Ltd PL 1001 02044 VTT Puh. +358 20 722 4911 Telekopio +358 20 722 7003 Rakennustuotedirektiivin

More information

Österreichisches Institut für Bautechnik Schenkenstrasse 4 1010 Vienna Austria T +43 1 533 65 50 F +43 1 533 64 23 mail@oib.or.at www.oib.or.

Österreichisches Institut für Bautechnik Schenkenstrasse 4 1010 Vienna Austria T +43 1 533 65 50 F +43 1 533 64 23 mail@oib.or.at www.oib.or. Authorised and notified according to Article 10 of the Council Directive 89/ 106/EEC of 21 December 1988 on the approximation of laws, regulations and administrative provisions of Member States relating

More information

European Technical Approval ETA 12/0419

European Technical Approval ETA 12/0419 FM Approvals Limited 1 Windsor Dials Windsor Berkshire SL4 1RS United Kingdom Tel.: +44 (0)1753 750000 Fax: +44 (0)1753 868700 E-mail: cpd@fmapprovals.com Internet: www.fmapprovals.com Member of EOTA European

More information

Europeiskt Tekniskt Godkännande European Technical Approval

Europeiskt Tekniskt Godkännande European Technical Approval SITAC Box 553 SE 371 23 Karlskrona SWEDEN MEMBER OF EOTA Tfn.: +46-(0)10-516 63 00 Fax: +46-(0)455-206 88 E-mail: info@sitac.se Europeiskt Tekniskt Godkännande European Technical Approval ETA-11/0380 Handelsnamn

More information

European Technical Approval ETA-11/0374

European Technical Approval ETA-11/0374 European Technical Approval ETA-11/0374 - Original version in German language Handelsbezeichnung Trade name Zulassungsinhaber Holder of approval Zulassungsgegenstand und Verwendungszweck Generic type and

More information

Policy Briefing. Frequently Asked Questions on the Construction Products Regulation and CE marking. December 2012. Background

Policy Briefing. Frequently Asked Questions on the Construction Products Regulation and CE marking. December 2012. Background Frequently Asked Questions on the Construction Products Regulation and CE marking December 2012 Background The following list of frequently asked questions has been produced by an MPA Working Group and

More information

Mandate M/111 CIRCULATION FIXTURES

Mandate M/111 CIRCULATION FIXTURES Mandate M/111 Page 1 sur 13 Mandate M/111 MANDATE TO CEN/CENELEC CONCERNING THE EXECUTION OF STANDARDISATION WORK FOR HARMONIZED STANDARDS ON CIRCULATION FIXTURES RELATED TO THE FOLLOWING END USES 30/33:

More information

Guidance from the Group of Notified Bodies for the Construction Products Directive 89/106/EEC. GNB-CPD position paper from SG17 - EN 1090-1:2009

Guidance from the Group of Notified Bodies for the Construction Products Directive 89/106/EEC. GNB-CPD position paper from SG17 - EN 1090-1:2009 GNB-CPD SG17 Guidance from the Group of Notified Bodies for the Construction Products Directive 89/106/EEC NB-CPD/SG17/09/069 Issued: 7 September 2009 APPROVED GUIDANCE GNB-CPD position paper from SG17

More information

Eurooppalainen tekninen hyväksyntä ETA - 13/0613 European Technical Approval

Eurooppalainen tekninen hyväksyntä ETA - 13/0613 European Technical Approval VTT Expert Services Ltd PL 1001 02044 VTT Puh. +358 20 722 4911 Telekopio +358 20 722 7003 Rakennustuotedirektiivin (89/106/EEC) artiklan 10, neuvoston direktiivi 21. joulukuuta 1988, mukaisesti notifioitu

More information

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011 CERTIFICATE NAME OF PRODUCT No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011 H-CONTROL REFLEX+ reflective insulating vapour control layer for roof and wall applications MANUFACTURER ACTIS

More information

European Technical Approval ETA-98/0001

European Technical Approval ETA-98/0001 European Technical Approval ETA-98/0001 - Original version in German language Handelsbezeichnung Trade name Zulassungsinhaber Holder of approval Zulassungsgegenstand und Verwendungszweck Generic type and

More information

Understanding BS EN 771-3: Aggregate concrete masonry units

Understanding BS EN 771-3: Aggregate concrete masonry units 60 Charles Street, Leicester LE1 1FB Tel: 0116 253 6161 Fax: 0116 251 4568 Email: enquiries@cba-blocks.org.uk Website: www.cba-blocks.org.uk February 2006 Understanding BS EN 771-3: Aggregate concrete

More information

(English language translation, the original version is in French language) Injection system Hilti HIT-HY 150 MAX

(English language translation, the original version is in French language) Injection system Hilti HIT-HY 150 MAX Centre Scientifique et Technique du Bâtiment 84 avenue Jean Jaurès CHAMPS-SUR-MARNE F-77447 Marne-la-Vallée Cedex 2 Tél. : (33) 01 64 68 82 82 Fax : (33) 01 60 05 70 37 Autorisé et notifié conformément

More information

Rakennustuotedirektiivin (89/106/EEC) artiklan 10, neuvoston direktiivi 21. joulukuuta 1988, mukaisesti notifioitu tuotehyväksyntälaitos EOTAN JÄSEN

Rakennustuotedirektiivin (89/106/EEC) artiklan 10, neuvoston direktiivi 21. joulukuuta 1988, mukaisesti notifioitu tuotehyväksyntälaitos EOTAN JÄSEN Page 1 of European Technical Approval ETA-09/0129 VTT Valtion Teknillinen Tutkimuskeskus PL 1000 02044 VTT Puh. +358 20 722 4911 Telekopio +358 20 722 7003 Rakennustuotedirektiivin (89/106/EEC) artiklan

More information

(English language translation, the original version is in French language) Chemical anchoring system WIT-200

(English language translation, the original version is in French language) Chemical anchoring system WIT-200 Centre Scientifique et Technique du Bâtiment 84 avenue Jean Jaurès CHAMPS-SUR-MARNE F-77447 Marne-la-Vallée Cedex 2 Tél. : (33) 01 64 68 82 82 Fax : (33) 01 60 05 70 37 Autorisé et notifié conformément

More information

European Technical Assessment. ETA-02/0020 of 22 September 2015. English translation prepared by DIBt - Original version in German language

European Technical Assessment. ETA-02/0020 of 22 September 2015. English translation prepared by DIBt - Original version in German language European Technical Assessment ETA-02/0020 of 22 September 2015 - Original version in German language General Part Technical Assessment Body issuing the European Technical Assessment: Trade name of the

More information

PRESENTATION ON REPAIR AND REHABILITATION OF BUILDINGS DAMAGED IN EARTHQUAKE. By H P Gupta & D K Gupta

PRESENTATION ON REPAIR AND REHABILITATION OF BUILDINGS DAMAGED IN EARTHQUAKE. By H P Gupta & D K Gupta PRESENTATION ON REPAIR AND REHABILITATION OF BUILDINGS DAMAGED IN EARTHQUAKE By H P Gupta & D K Gupta DIFFERENT TYPES OF DAMAGES 1.Minor cracks 0.5 to 5 mm wide in load or non-load bearing walls 2.Major

More information

IMQ RULES. Contents. IMQ Rules - Product certification

IMQ RULES. Contents. IMQ Rules - Product certification IMQ RULES PRODUCT CERTIFICATION "ELECTRIC ENERGY METERS AND METER UNITS" PRODUCT OF NEW MANUFACTURING Contents IMQ Rules - Product certification Particular Rules for the Electric energy meters and meter

More information

How To Write A European Technical Assessment

How To Write A European Technical Assessment European Technical Assessment Regulation Date of UBAtc Board of directors acceptance: 16 September 2013 Date of entry into force: 16 September 2013 This version does not supersede any previous version

More information

Section 8.1 Volume I QUALITY ASSURANCE PROGRAM OF PRECAST PRESTRESSED CONCRETE PRODUCTS

Section 8.1 Volume I QUALITY ASSURANCE PROGRAM OF PRECAST PRESTRESSED CONCRETE PRODUCTS Section 8.1 Volume I QUALITY ASSURANCE PROGRAM OF PRECAST PRESTRESSED CONCRETE PRODUCTS 8.1.1 PURPOSE This procedure provides guidelines related to the implementation of quality control and quality assurance

More information

AVERTISSEMENT Vous trouverez ci-dessous la version française de ce Guidance Paper suivie de la version anglaise

AVERTISSEMENT Vous trouverez ci-dessous la version française de ce Guidance Paper suivie de la version anglaise AVERTISSEMENT Vous trouverez ci-dessous la version française de ce Guidance Paper suivie de la version anglaise !!"#$%$ %$ &'# %%%( $ # $ %$ # %%") %$ #% $!* $(%$ ($%% +$ (,& #$- * ($%%* $ $ % + $%%$ %!%%

More information

Strengthening of Large Storage Tank Foundation Walls in an Aggressive Environment by External Post-tensioning. May 7th 2013: Dominique Deschamps

Strengthening of Large Storage Tank Foundation Walls in an Aggressive Environment by External Post-tensioning. May 7th 2013: Dominique Deschamps Strengthening of Large Storage Tank Foundation Walls in an Aggressive Environment by External Post-tensioning May 7th 2013: Dominique Deschamps Scope of the paper Presentation of the project Cause of cracks

More information

COMPETENCY ANALYSIS PROFILE. Rodworker 452A. (All unshaded skill sets must be demonstrated/ completed) Lift equipment and materials

COMPETENCY ANALYSIS PROFILE. Rodworker 452A. (All unshaded skill sets must be demonstrated/ completed) Lift equipment and materials COMPETENCY ANALYSIS PROFILE Rodworker 452A (All unshaded skill sets must be demonstrated/ completed) PROTECT SELF AND OTHERS Wear personal protective (PPE) Lift and Apply housekeeping rules Interpret warning

More information

This European technical approval

This European technical approval Authorised and notified according to Article 10 of the Council Directive 89/ 106/EEC of 21 December 1988 on the approximation of laws, regulations and administrative provisions of Member States relating

More information

The certification of European construction products

The certification of European construction products The certification of European construction products Every year, SCOR Global P&C s Inherent Defects team organises a morning seminar for its clients (Matinée Décennale), during which a technical subject

More information

Force measurement. Forces VECTORIAL ISSUES ACTION ET RÉACTION ISOSTATISM

Force measurement. Forces VECTORIAL ISSUES ACTION ET RÉACTION ISOSTATISM Force measurement Forces VECTORIAL ISSUES In classical mechanics, a force is defined as "an action capable of modifying the quantity of movement of a material point". Therefore, a force has the attributes

More information

Quality Product Certification Scheme for Mechanical Couplers (QS/MC)

Quality Product Certification Scheme for Mechanical Couplers (QS/MC) Quality Product Certification Scheme for Mechanical Couplers (QS/MC) Kenneth Kau Castco Certification Services Limited 13 November 2015 Quality Assurance Manager & Product Certification Auditor Summary

More information

VdS 2100-09en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS 2100-09en : 2011-05 (01)

VdS 2100-09en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS 2100-09en : 2011-05 (01) VdS Guidelines for water extinguishing systems VdS 2100-09en Requirements and test methods VdS 2100-09en : 2011-05 (01) Publishing house: VdS Schadenverhütung GmbH Amsterdamer Str. 172-174 50735 Köln,

More information

HUS-V Screw anchor. HUS-V Screw anchor. Basic loading data (for a single anchor) Mean ultimate resistance

HUS-V Screw anchor. HUS-V Screw anchor. Basic loading data (for a single anchor) Mean ultimate resistance HUS-V Screw anchor Anchor version HUS-V 8 / 10 Carbon steel concrete screw with hexagonal head Benefits - High productivity less drilling and fewer operations than with conventional anchors - Technical

More information

Specification for Rotary Drill Stem Elements

Specification for Rotary Drill Stem Elements Addendum 1 March 2007 Effective Date: September 1, 2007 Specification for Rotary Drill Stem Elements ANSI/API SPECIFICATION 7-1 FIRST EDITION, MARCH 2006 EFFECTIVE DATE: SEPTEMBER 2006 ISO 10424-1:2004

More information

SECTION 03400 PRECAST CONCRETE STRUCTURES

SECTION 03400 PRECAST CONCRETE STRUCTURES SECTION 03400 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes specifications for precast concrete structures, including fabrication and erection. 1.02 REFERENCE STANDARDS A. American Society for

More information

TECHNICAL SPECIFICATION SERIES 8000 PRECAST CONCRETE

TECHNICAL SPECIFICATION SERIES 8000 PRECAST CONCRETE TECHNICAL SPECIFICATION SERIES 8000 PRECAST CONCRETE TECHNICAL SPECIFICATION PART 8000 - PRECAST CONCRETE TABLE OF CONTENTS Item Number Page 8100 PRECAST CONCRETE CONSTRUCTION - GENERAL 8-3 8101 General

More information

FAMI-QS Certification Rules for Operators. Rules for Operators

FAMI-QS Certification Rules for Operators. Rules for Operators Rules for Operators TABLE OF CONTENTS 1. Application for certification and FAMI QS associate membership...2 2. Assessment of operators...3 2.1. Audit planning...3 2.2. Frequency of audits and re certification...5

More information

CE mark now! Mandatory CE marking of construction products 1 July 2013

CE mark now! Mandatory CE marking of construction products 1 July 2013 CE mark now! Mandatory CE marking of construction products 1 July 2013 Mandatory CE marking of construction products 1 July 2013 From 1 July 2013, construction products covered by a harmonised standard

More information

ISO/IEC 17025 QUALITY MANUAL

ISO/IEC 17025 QUALITY MANUAL 1800 NW 169 th Pl, Beaverton, OR 97006 Revision F Date: 9/18/06 PAGE 1 OF 18 TABLE OF CONTENTS Quality Manual Section Applicable ISO/IEC 17025:2005 clause(s) Page Quality Policy 4.2.2 3 Introduction 4

More information

EUROPEAN COMMISSION ENTERPRISE AND INDUSTRY DIRECTORATE-GENERAL. EudraLex The Rules Governing Medicinal Products in the European Union.

EUROPEAN COMMISSION ENTERPRISE AND INDUSTRY DIRECTORATE-GENERAL. EudraLex The Rules Governing Medicinal Products in the European Union. EUROPEAN COMMISSION ENTERPRISE AND INDUSTRY DIRECTORATE-GENERAL Consumer goods Pharmaceuticals Brussels, 03 February 2010 ENTR/F/2/AM/an D(2010) 3374 EudraLex The Rules Governing Medicinal Products in

More information

TECHNICAL NOTE Culvert Sliplining and Lining of Casings with HPPipe

TECHNICAL NOTE Culvert Sliplining and Lining of Casings with HPPipe TECHNICAL NOTE Culvert Sliplining and Lining of Casings with HPPipe TN 5.14 February 2010 Introduction It may be at times necessary, in an aging infrastructure, to rehabilitate drainage and sanitary lines

More information

Introduction. Eurocodes. Specification. Cost

Introduction. Eurocodes. Specification. Cost Introduction Eurocodes Specification Cost Structural Eurocodes BS EN 1990 (EC0): BS EN 1991 (EC1): Basis of structural design Actions on Structures BS EN 1992 (EC2): BS EN 1993 (EC3): BS EN 1994 (EC4):

More information