Technical Data Manual Model Nos. and pricing: see Price List

Size: px
Start display at page:

Download "Technical Data Manual Model Nos. and pricing: see Price List"

Transcription

1 Tehnial Data Manual Model Nos. and priing: see Prie List Vitoell 100-V CVAA and CVA Series Indiret-fired domesti hot water storage tank 42 USG to 119 USG (160 L to 450 L) apaity Indiret-fired domesti hot water storage tank steel onstrution, with Ceraprotet enamel oating. Produt may not be exatly as shown CAUTION This tank version is not suitable for steam heating appliations. 12/2015

2 Produt Information Benefits Vitoell 100-V, CVA/CVAA Series Tehnial Data The vertial tank solution for ost-effiient domesti hot water supply. The Vitoell 100-V DHW tank offers storage apaities of up to 119 USG (450 L). Benefits at a glane: Corrosion-proteted steel tank shell with Ceraprotet enamel oating. Magnesium anode provides additional athodi tank protetion. Heat exhanger oil extends to the bottom of the tank, thereby heating the entire water ontent. Extremely onvenient domesti hot water supply assured by fast, uniform heating via generously sized heat exhanger surfaes. Certified to CSA Low Lead Content Certifiation Program; inluding US Safe Drinking Water At, NSF/ANSI 372 as well as other appliable US State requirements. Universally suitable - for appliations requiring larger quantities of hot water, multiple Vitoell 100-V tanks may be onneted to a header to form a tank battery. Inreased energy savings thanks to highly effetive, foamed-in-plae HCFC-free insulation keeping standby losses at a minimum. The vitoell-v USG (450 L) apaity tank is supplied with removable soft PET insulation for easier handling. 2

3 Vitoell 100-V, CVA/CVAA Series Tehnial Data Cross Setion Produt Information 3

4 Tehnial Data Tehnial Data Vitoell 100-V, CVA/CVAA Series Tehnial Data For domesti hot water heating appliations in onjuntion with hot water heating boilers Suitable for heating systems with: max. working pressure on the heat exhanger side of up to 150 psig (10 bar) max. working pressure on DHW side of up to 150 psig (10 bar) max. supply temperature on the heat exhanger side of up to 230 F (110 C) max. DHW supply temperature of up to 150 F (65.6 C) Tank series CVA CVA CVAA CVA Storage apaity USG (L) 42 (160) 53 (200) 79 (300) 119 (450) Reovery rates*1 MBH (kw) 136 (40) 136 (40) 180 (53) 238 (70) 194ºF (90ºC) with a DHW temperature GPH (L/h) 258 (982) 258 (982) 342 (1302) 456 (1720) inrease from 50 to 113ºF MBH (kw) 109 (32) 109 (32) 150 (44) 198 (58) 176ºF (80ºC) (10 to 45ºC) and a supply water GPH (L/h) 210 (786) 210 (786) 288 (1081) 378 (1425) temperature of... MBH (kw) 85 (25) 85 (25) 113 (33) 153 (45) 158ºF (70ºC) GPH (L/h) 162 (614) 162 (614) 216 (811) 294 (1106) MBH (kw) 58 (17) 58 (17) 78 (23) 109 (32) 140ºF (60ºC) GPH (L/h) 108 (417) 108 (417) 149 (565) 210 (786) MBH (kw) 31 (9) 31 (9) 61 (18) 82 (24) 122ºF (50ºC) GPH (L/h) 60 (221) 60 (221) 114 (442) 156 (589) Reovery rates*1 MBH (kw) 123 (36) 123 (36) 153 (45) 181 (53) 194ºF (90ºC) with a DHW temperature GPH (L/h) 164 (619) 164 (619) 204 (774) 240 (911) inrease from 50 to 140ºF MBH (kw) 95 (28) 95 (28) 116 (34) 150 (44) 176ºF (80ºC) (10 to 60ºC) and a supply water GPH (L/h) 120 (482) 120 (482) 156 (584) 198 (756) temperature of... MBH (kw) 65 (19) 65 (19) 78 (23) 113 (33) 158ºF (70ºC) GPH (L/h) 84 (327) 84 (327) 102 (395) 150 (567) Supply flow rate for the reovery rates stated GPM (m 3/ h) 13.2 (3.0) 13.2 (3.0) 13.2 (3.0) 13.2 (3.0) Insulation PUR Foam PUR Foam PUR Foam Soft PET Standby losses*2 MBH/24 h *1 When planning for the reovery rate as stated or alulated, allow for the orresponding irulation pump. The stated reovery rate is only ahieved when the rated output of the boiler is equal to or greater than that stated under Reovery rate. Please also refer to the orresponding sizing hart at the end of this manual. *2 Measured values are based on a room temp. of 68 F (20ºC) and a domesti hot water temp. of 149 F (65ºC) and an vary by 5%. *3 For other dimensions, see illustration and table on page 5. *4 Adjustable feet an be adjusted up to 2 in. (50 mm). For information regarding other Viessmann System Tehnology omponentry, please referene the doumentation of the respetive produt. 4 Dimensions *3 Tank length without insulation Overall length with insulation Tank width without insulation Overall width with insulation Tank height without insulation Overall height with insulation*4 Tilt height without insulation Tilt height with insulation 23 (581) 24 (605) 47 (1189) 50 (1260) 23 (581) 24 (605) 55b (1409) 57b (1460) 26a (667) 29a (744) 68a (1734) 72 (1825) 34 (859) 33 (837) 36a (923) 76 (1948) 72b (1844) 73a (1860) Weight Tank with insulation lbs (kg) 190 (86) 214 (97) 333 (151) 399 (181) Heat exhanger oil liquid ontent USG (L) 1.45 (5.5) 1.45 (5.5) 2.6 (10) 3.3 (12.5) Heat exhanger surfae area ft. 2 (m 2 ) 10.8 (1) 10.8 (1) 16.1 (1.5) 20.5 (1.9) Connetions Heating water supply/return Domesti old/hot water T&P valve Reirulation in. (male NPT thread) in. (male NPT thread) in. (female NPT thread) in. (male NPT thread) a 1

5 Vitoell 100-V, CVA/CVAA Series Tehnial Data CVA 42 and 53 USG (160 and 200 L) Tank Dimensions Tehnial Data Dimensions Storage apaity b d e f h USG (L) 42 (160) 53 (200) 2 (72) 9 (249) 25 (634) 35 (884) 41 (1050) 12b (317) 2 (72) 9 (249) 25 (634) 35 (884) 41 (1050) 12b (317) Legend IO Inspetion and lean-out opening D Drain BWR Boiler water return (upper oil) BWS Boiler water supply (upper oil) DCW Domesti old water AQ Aquastat well (at the same height as the boiler water supply onnetion) DHW Domesti hot water RT Reirulation tapping TPV Temperature and pressure relief valve MA Protetive magnesium anode 5

6 Tehnial Data CVAA 79 USG (300 L) Tank Dimensions Vitoell 100-V, CVA/CVAA Series Tehnial Data Dimensions Storage apaity USG (L) 79 (300) a b d e f g h j 13 (333) 3 (76) 10 (260) 34b (875) 44 (1115) 63 (1600) 26 (660) 14a (361) 4 (100) Legend IO Inspetion and lean-out opening D Drain BWR Boiler water return (upper oil) BWS Boiler water supply (upper oil) DCW Domesti old water AQ Aquastat well (at the same height as the boiler water supply onnetion) DHW Domesti hot water RT Reirulation tapping TPV Temperature and pressure relief valve MA Protetive magnesium anode 6

7 Vitoell 100-V, CVA/CVAA Series Tehnial Data CVA 119 USG (450 L) Tank Dimensions Tehnial Data Dimensions Storage apaity USG (L) 119 (450) a b d e f g h j 16b (422) 4 (100) 13 (349) 36a (924) 48b (1230) 70a (1784) 33 (837) 18 (455) 4 (100) Legend IO Inspetion and lean-out opening D Drain BWR Boiler water return (upper oil) BWS Boiler water supply (upper oil) DCW Domesti old water AQ Aquastat well (at the same height as the boiler water supply onnetion) DHW Domesti hot water RT Reirulation tapping TPV Temperature and pressure relief valve MA Protetive magnesium anode 7

8 Tehnial Data Water Flow Vitoell 100-V, CVA/CVAA Series Tehnial Data Domesti hot water draw rate Storage tank ontents heated to 140ºF (60ºC), boiler not reheating Storage apaity USG (L) 42 (160) 53 (200) 79 (300) 119 (450) Domesti draw rate GPM (L/min) 2.6 (10) 2.6 (10) 4.0 (15) 4.0 (15) Domesti hot water draw Water with t = 140ºF (60ºC) (onstant) USG (L) 32 (120) 38 (145) 63 (240) 111 (420) Perentage tank volume % Heat-up time The stated heating times are ahieved when the maximum reovery rate of the domesti hot water tank is made available at the respetive supply temperature and with a domesti hot water rise from 50 to 140 F (10 to 60 C). Storage apaity USG (L) 42 (160) 53 (200) 79 (300) 119 (450) Heating water supply temperature 194 F (90 C) 176 F (80 C) 158 F (70 C) Heat-up time (minutes) Pressure drop on heating water side (primary iruit) Pressure drop on domesti hot water side (seondary iruit) Legend A 42 USG (160 L) and 53 USG (200 L) storage apaities B 79 USG (300 L) storage apaity C 119 USG (450 L) storage apaity 8

9 Vitoell 100-V, CVA/CVAA Series Tehnial Data Multiple Tank Installation Produt Installation Tehnial Data The 79 and 119 USG (300 and 450 L) tank sizes may be ombined into a battery onsisting of between 2 and 3 tanks. Tank batteries onsisting of more than 3 tanks an be installed by reating up to 4 batteries, eah onsisting of 3 tanks. The heating ontrator is responsible to ensure proper piping on both the primary and seondary iruits. Tank series CVAA CVA Storage apaity USG (L) 79 (300) 119 (450) Total apaity of tank battery USG (L) 159 (600) 238 (900) 357 (1350) Number of storage tanks Reovery rates*1 with a DHW temperature inrease from 50 to 113ºF (10 to 45ºC) and a supply water temperature of... Reovery rates*1 with a DHW temperature inrease from 50 to 140ºF (10 to 60ºC) and a supply water temperature of... MBH (kw) 194ºF (90ºC) GPH (L/h) MBH (kw) 176ºF (80ºC) GPH (L/h) MBH (kw) 158ºF (70ºC) GPH (L/h) MBH (kw) 140ºF (60ºC) GPH (L/h) MBH (kw) 122ºF (50ºC) GPH (L/h) MBH (kw) 194ºF (90ºC) GPH (L/h) MBH (kw) 176ºF (80ºC) GPH (L/h) MBH (kw) 158ºF (70ºC) GPH (L/h) 361 (106) 690 (2604) 300 (88) 570 (2162) 225 (66) 426 (1622) 157 (46) 300 (1130) 123 (36) 234 (884) 307 (90) 408 (1548) 232 (68) 306 (1168) 157 (46) 210 (790) 477 (140) 906 (3440) 396 (116) 750 (2850) 307 (90) 582 (2212) 218 (64) 414 (1572) 164 (48) 312 (1178) 361 (106) 480 (1822) 300 (88) 402 (1512) 225 (66) 300 (1134) 716 (210) 1362 (5160) 593 (174) 1128 (4275) 460 (135) 876 (3318) 327 (96) 624 (2358) 246 (72) 468 (1767) 542 (159) 720 (2733) 450 (132) 600 (2268) 338 (99) 450 (1701) Supply flow rate for the reovery rates stated GPM (m 3/h ) 26.4 (6) 26.4 (6) 39.6 (9) Standby losses*2 MBH/24 h Dimensions Tank length without insulation Overall length with insulation Tank width without insulation Overall width with insulation Tank height without insulation Overall height with insulation Weight 57b (1495) 43b (1148) 69 (1734) 72b (1838) 48 (1218) 77 (1955) 111a (2826) 48 (1218) 77 (1955) Tank with insulation lbs (kg) 736a (334) 932 (423) 1409 (639) Heating water ontent USG (L) 6b (25) 8b (32) 13 (50) (heat exhanger pipe oil) Heat exhanger surfae area ft. 2 (m 2 ) 32a (3.0) 42 (3.9) 62b (5.8) *1 When planning for the reovery rate as stated or alulated, allow for the orresponding irulation pump. The stated reovery rate is only ahieved when the rated output of the boiler is equal to or greater than that stated under Reovery rate. Please also refer to the orresponding sizing hart at the end of this manual. *2 Measured values are based on a room temperature of 68 F (20ºC) and a domesti hot water temperature of 149 F (65ºC) and an vary by 5%. 9

10 Produt Installation Multiple Tank Installation (ontinued) Vitoell 100-V, CVA/CVAA Series Tehnial Data For domesti hot water appliations whih utilize modulating and low temperature hot water heating boilers or remote heating plants. 3 tanks 2 tanks Legend IO Inspetion and lean-out opening D Drain A Air vent BWR Boiler water return BWS Boiler water supply DCW Domesti old water DHW Domesti hot water RT Reirulation tapping TPV T&P valve top view Dimensions Tank series CVAA CVA Storage apaity 79 (300) 119 (450) Total apaity of battery USG (L) 159 (600) 238 (900) 357 (1350) Number of storage tanks USG (L) a b d e f 3 (76) 10a (260) 34b (875) 68a (1734) 14a (361) 8 (206) 4a (107) 13 (349) 36a (924) 70a (1948) 18 (455) 12b (320) 4a (107) 13 (349) 36a (924) 70a (1948) 18 (455) 12b (320) 10

11 Vitoell 100-V, CVA/CVAA Series Tehnial Data Multiple Tank Installation (ontinued) Produt Installation Domesti hot water draw rate Storage tank ontents heated to 140ºF (60ºC) Tank series CVAA CVA Storage apaity USG (L) 79 (300) 119 (450) Battery storage apaity USG (L) 159 (600) 238 (900) 357 (1350) Number of storage tanks Domesti draw rate GPM (L/min) 7.9 (30) 7.9 (30) 7.9 (30) Domesti hot water draw Water with t = 140ºF (60ºC) (onstant) USG (L) 127 (480) 222 (840) 333 (1260) Perentage tank volume % Quik reovery (over 10-minute period) Domesti hot water rise from 50 to 113 F (10 to 45 C) Tank series CVAA CVA Storage apaity USG (L) 79 (300) 119 (450) Battery storage apaity USG (L) 159 (600) 238 (900) 357 (1350) Number of storage tanks Heating water supply temperature 194 F (90 C) 176 F (80 C) 158 F (70 C) USG/10 min (L/10 min) USG/10 min (L/10 min) USG/10 min (L/10 min) Quik DHW reovery (over 10-minute period) 201 (759) 197 (745) 192 (728) 304 (1150) 287 (1088) 268 (1016) 425 (1610) 401 (1520) 370 (1400) Max. domesti hot water draw rate (over 10-minute period) Domesti hot water rise from 50 to 113 F (10 to 45 C) Tank series CVAA CVA Storage apaity USG (L) 79 (300) 119 (450) Battery storage apaity USG (L) 159 (600) 238 (900) 357 (1350) Number of storage tanks Heating water supply temperature 194 F (90 C) 176 F (80 C) 158 F (70 C) GPM (L/min) GPM (L/min) GPM (L/min) Max. DHW draw rate (over 10-minute period) 20.1 (76) 20 (74) 19.3 (73) 30 (115) 29 (109) 27 (102) 43 (161) 40 (152) 37 (140) 11

12 Produt Installation Standard Equipment Vitoell 100-V, CVA/CVAA Series Tehnial Data This is a simplified oneptual drawing only! Piping and neessary omponentry must be field verified. Proper installation and funtionality in the field is the responsibility of the heating ontrator. Legend A Domesti hot water supply B DHW reirulation line C DHW reirulation pump D Spring-loaded flow hek valve E Disharge pipe F Temperature and pressure relief valve (TPV) G Shut-off valve H Drain K Domesti old water supply lines L Bakflow preventer M Domesti old water inlet N Preharged expansion tank (required where bakflow preventer is installed; hek loal plumbing odes and requirements) O Thermostati mixing valve/anti-sald valve for solar appliations (field supplied) Vitoell 100-V 42 to 79 USG (160 to 300 L) apaity Domesti hot water storage tank of high-grade steel with PUR Foam insulation (HCFC-free) and Ceraprotet enamel oating with: thermometer adjustable leveling feet built-in aquastat well Magnesium anode The following is paked separately and attahed to the rate: installation fittings pakage: with the neessary hardware temperature and pressure relief valve. Eletrostatially powder-oated sheet metal enlosure panel in a Vitosilver finish. Vitoell 100-V 119 USG (450 L) apaity Domesti hot water storage tank of high-grade steel with wrap-around soft PET insulation (HCFC-free) and Ceraprotet enamel oating with: thermometer adjustable leveling feet built-in aquastat well Magnesium anode The following is paked separately and attahed to the rate: installation fittings pakage: with the neessary hardware temperature and pressure relief valve. Syntheti wrap-around enlosure panel in a Vitosilver finish. 12

13 Vitoell 100-V, CVA/CVAA Series Tehnial Data Standard Equipment (ontinued) Produt Installation Bakflow preventers Where bakflow preventers are required, a domesti water expansion tank installation is reommended in the old water inlet piping before the old water enters the Vitoell. For the bakflow devie, observe loal plumbing odes and regulations. Temperature and pressure relief valve A temperature and pressure relief valve (T&P relief valve) is supplied with the tank. The heating ontrator must install the valve on eah tank in a method meeting ode requirements. If loal odes require a different relief valve, substitute the manufaturer s supplied valve. The tank is approved for 150 psig. Maximum operating pressure is 150 psig. The T&P relief valve supplied with the tank is tested under ANSI Z21.22 Code for Relief Valves and Automati Gas Shut-off Devies for Hot Water Supply Systems. IMPORTANT Sine the heat exhanger oil allows for high MBH input (see Vitoell flow harts), onfirmation that the appropriate and orret size pressure and temperature relief valve is used and installed, is neessary. T&P Valve ASME pressure steam rating CSA temperature steam rating Relief temperature Inlet thread Outlet thread 100 psig 150 psig (where CRN is required) see ratings marked on T&P valve 205 MBH 210 F (99 C) male female Warranty Our warranty for domesti hot water tanks states that the water heated must be of drinking (potable) water quality and that any water treatment equipment in use must funtion orretly. Viessmann aepts no responsibility for damage howsoever aused and reserves the right to withdraw the produt warranty if the produt has been improperly installed or misapplied by the installer, ontrator or final user. In order to qualify for produt warranty, strit adherene to the installation and servie manuals must be assured. In the event that Viessmann nonapproved omponents are utilized, Viessmann reserves the right to withdraw all expressed or implied warranties without written notie. The water to be heated with the Vitoell must be drinking (potable) water quality. If the tank is used to heat other media, the warranty will be null and void. Damage resulting from exessive pressure or temperature is learly not the responsibility of Viessmann. The amount of hloride and sulfate aeptable to the tank is limited. In areas where high onentrations of hloride and sulfate are present in drinking water, please onsult Viessmann for diretions. Sensor Well Vitoell 100-V, 42 to 119 USG (160 to 450 L) apaity The sensor well is welded into the domesti hot water storage tank. 13

14 Sizing Continuous Flow Capaity Chart Vitoell 100-V, CVA/CVAA Series Tehnial Data CVA, 42 and 53 USG (160 and 200 L) apaities Curve A Domesti hot water 40 to 113 F (4 to 45 C) Curve B Domesti hot water 40 to 140 F (4 to 60 C) 14

15 Vitoell 100-V, CVA/CVAA Series Tehnial Data Continuous Flow Capaity Chart (ontinued) Sizing CVAA, 79 USG (300 L) apaity Curve A Domesti hot water 40 to 113 F (4 to 45 C) Curve B Domesti hot water 40 to 140 F (4 to 60 C) 15

16 Sizing Continuous Flow Capaity Chart (ontinued) Vitoell 100-V, CVA/CVAA Series Tehnial Data CVA, 119 USG (450 L) apaity Curve A Domesti hot water 40 to 113 F (4 to 45 C) Curve B Domesti hot water 40 to 140 F (4 to 60 C) 16

17 Vitoell 100-V, CVA/CVAA Series Tehnial Data Continuous Flow Capaity Chart (ontinued) Sizing Example: CVA, 119 USG (450 L) apaity Assume the boiler output to the tank is 170 MBH. Enter hart at left and draw horizontal line aross to reovery rate of 203 GPH or 3.4 GPM for 140 F (60 C) domesti hot water under olumn B. Where the horizontal line intersets the 194 F (90 C) urve is the point of intersetion for the diagonal line used to size the pump. The diagonal line begins at the origin and goes through the point of intersetion extending up to the top of the hart. Read between the referene diagonal lines to get a pump speifiation of 11.9 GPM at 5 ft. To summarize: For a Vitoell-V 100 with 119 USG (450 L) apaity and 170 MBH input, the boiler water temperature is 194 F (90 C), differene between boiler return and supply water temperature is 31 F (17 C), reovery rate is 3.4 GPM of 140 F (60 C) DHW, and the pump required is 11.9 GPM, 5 ft. plus pressure drop in piping and boiler. 17

18 Vitoell 100-V, CVA/CVAA Series Tehnial Data 18

19 Vitoell 100-V, CVA/CVAA Series Tehnial Data 19

20 Vitoell 100-V, CVA/CVAA Series Tehnial Data Tehnial information subjet to hange without notie. Printed on environmentally friendly (reyled and reylable) paper.

Technical Data Manual Model Nos. and pricing: see Price List

Technical Data Manual Model Nos. and pricing: see Price List VITOCELL-V 00 Indirect-fired domestic hot water storage tank 4 to 0 / 60 to Technical Data Manual Model Nos. and pricing: see Price List Vitocell-V 00 4 to / 60 to Vitocell-V 00 0 / Vitocell-V 00 CVA Series

More information

WATER CLOSET SUPPORTS TECHNICAL DATA

WATER CLOSET SUPPORTS TECHNICAL DATA WATER CLOSET SUPPORTS TECHNICAL DATA Smith engineers have developed an unusually omplete line of fixture supports for mounting all types of "off the floor" fixtures. Supports have been designed for water

More information

Computational Analysis of Two Arrangements of a Central Ground-Source Heat Pump System for Residential Buildings

Computational Analysis of Two Arrangements of a Central Ground-Source Heat Pump System for Residential Buildings Computational Analysis of Two Arrangements of a Central Ground-Soure Heat Pump System for Residential Buildings Abstrat Ehab Foda, Ala Hasan, Kai Sirén Helsinki University of Tehnology, HVAC Tehnology,

More information

Light Duty Commercial Electric Water Heater

Light Duty Commercial Electric Water Heater Features Heavy Duty Construction Hydrastone cement lining provides longer tank life Copper-silicon tappings cannot rust or corrode High impact composite jacket eliminates damage during installation and

More information

PRO-CLEAN. Technical Description. Specifications. Space-saving design with minimum heat loss (melamine resin insulation)

PRO-CLEAN. Technical Description. Specifications. Space-saving design with minimum heat loss (melamine resin insulation) PRO-CLEAN Product description Specifications Technical Description Max. backup operating pressure Max. service water operating pressure 3 bar 6 bar Hot water connection " female thread* V4A (no..4) Cold

More information

Commercial Gas Water Heaters

Commercial Gas Water Heaters CYCLONE Mxi MODULATING MODULATING BURNER ADVANCES THE CYCLONE TO HIGHER LEVELS OF EFFICIENCY The full line of A. O. Smith Cyclone Mxi condensing water heaters has been designed to provide years of dependable

More information

State of Maryland Participation Agreement for Pre-Tax and Roth Retirement Savings Accounts

State of Maryland Participation Agreement for Pre-Tax and Roth Retirement Savings Accounts State of Maryland Partiipation Agreement for Pre-Tax and Roth Retirement Savings Aounts DC-4531 (08/2015) For help, please all 1-800-966-6355 www.marylandd.om 1 Things to Remember Complete all of the setions

More information

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS Contents Page Ratings and Specifications..................... 2 Installation Requirements......................

More information

Series GM. Peerless Boilers. Residential/Commercial Gas Boilers

Series GM. Peerless Boilers. Residential/Commercial Gas Boilers Peerless Boilers Series GM Residential/Commercial Gas Boilers The Series GM cast iron, hot water boiler is ideal for use in large residences or commercial applications. This gas-fired, atmospheric boiler

More information

BENEFICIARY CHANGE REQUEST

BENEFICIARY CHANGE REQUEST Poliy/Certifiate Number(s) BENEFICIARY CHANGE REQUEST *L2402* *L2402* Setion 1: Insured First Name Middle Name Last Name Permanent Address: City, State, Zip Code Please hek if you would like the address

More information

G234X-55 Conventional Gas Boiler

G234X-55 Conventional Gas Boiler Engineering Submittal Sheet Boiler Overview C US Engineering Specifications There shall be provided and installed a quantity of Buderus G234X-55 fl oor standing hot water boiler(s), suitable with natural

More information

ASME Packaged Indirect Fired Water Heater

ASME Packaged Indirect Fired Water Heater Utilizes Or HTHW To Heat Domestic Water, Semi-Instantaneous or Storage Type Model BW Features Reliable Only high grade materials used in construction to ensure long operating life Hydrastone cement lining

More information

HOW TO CALCULATE PRESSURE ANYWHERE IN A PUMP SYSTEM? Jacques Chaurette p. eng. www.lightmypump.com April 2003

HOW TO CALCULATE PRESSURE ANYWHERE IN A PUMP SYSTEM? Jacques Chaurette p. eng. www.lightmypump.com April 2003 HOW TO CALCULATE PRESSURE ANYWHERE IN A PUMP SYSTEM? Jaques Chaurette p. en. www.lihtmypump.om April 003 Synopsis Calulatin the total head of the pump is not the only task of the pump system desiner. Often

More information

Technical Data Manual

Technical Data Manual Technical Data Manual Model Nos. and pricing: see Price List Vitodens 100-W WB1B Series Wall-Mounted, gas-fired condensing boiler with optional on demand hot water CombiPLUS Kit Heating input: 37 to 118

More information

INSTALLATION AND SERVICE MANUAL EPJ SERIES INDIRECT WATER HEATERS

INSTALLATION AND SERVICE MANUAL EPJ SERIES INDIRECT WATER HEATERS INSTALLATION AND SERVICE MANUAL EPJ SERIES INDIRECT WATER HEATERS FOR MODELS EPJ-40 AND EPJ-56 SEE REAR COVER FOR INDEX Read this instruction manual before installation, operation, or service. Failure

More information

ECOplus Solar Cylinder

ECOplus Solar Cylinder TECHNICAL INFORMATION Solar Cylinder Wagner& Co Connection Options for CONVECTROL II The Effective Convection Brake Technically and fluidically optimized barriers separate the water cooled in the pipes

More information

Performance Rating of Unitary Air-Conditioning & Air-Source Heat Pump Equipment

Performance Rating of Unitary Air-Conditioning & Air-Source Heat Pump Equipment ANSI/AHRI Standard 210/240 with Addenda 1 and 2 (formerly ARI Standard 210/240) 2008 Standard for Performane Rating of Unitary Air-Conditioning & Air-Soure Heat Pump Equipment Approved by ANSI in Deember

More information

F220 Series. Installation Instructions. Photoelectric Smoke/Heat Detectors

F220 Series. Installation Instructions. Photoelectric Smoke/Heat Detectors F0 Series EN Installation Instrutions Photoeletri Smoke/Heat Detetors F0 Series Installation Instrutions.0 General Information EN.0 General Information. F0-B6 Series Bases Use with the F0 Series Heat and

More information

RECON WATER HEATER INSTALLATION FORM

RECON WATER HEATER INSTALLATION FORM RECON WATER HEATER INSTALLATION FORM Please complete ONE (1) form for each SITE and return to AERCO for warranty validation within 30 days of start-up. After completion, e-mail this form to: STARTUP@AERCO.COM.

More information

Electric Flow Boiler

Electric Flow Boiler Electric Flow Boiler EHC offer the most comprehensive range of electric boilers in the market and with our wealth of knowledge and technical expertise we have designed the Slim Jim Electric Flow Boiler

More information

Steam System Best Practices Condensate System Piping

Steam System Best Practices Condensate System Piping Steam System Best Practices Condensate System Piping Summary The best method for improving steam system energy efficiency, reducing chemical costs, and reducing make-up water costs is to return the maximum

More information

TS150 Visible (exposed) fixing with screws on a timber sub-frame

TS150 Visible (exposed) fixing with screws on a timber sub-frame TS150 Visile (exposed) fixing with srews on a timer su-frame This system offers a ost effetive solution for installing Trespa Meteon panels in a large variety of panel dimensions. Trespa Meteon panels

More information

Commercial Electric Water Heater

Commercial Electric Water Heater MODEL SE Commercial Electric Water Heater 6-120 Gallon Capacity, up to 58 KW in all Three Phase Voltages, Over 6 KW in all Single Phase Voltages Features Heavy Duty Construction Hydrastone cement lining

More information

Better Boilers. www.ibcboiler.com

Better Boilers. www.ibcboiler.com Better Boilers FEATURING OUR IBC SUPREME SUPER COIL 316TI STAINLESS STEEL HEAT EXCHANGER. From the factory in Vancouver, our uniquely designed and engineered Super Coil VFC Heat Exchanger is the best Heat

More information

OpenScape 4000 CSTA V7 Connectivity Adapter - CSTA III, Part 2, Version 4.1. Developer s Guide A31003-G9310-I200-1-76D1

OpenScape 4000 CSTA V7 Connectivity Adapter - CSTA III, Part 2, Version 4.1. Developer s Guide A31003-G9310-I200-1-76D1 OpenSape 4000 CSTA V7 Connetivity Adapter - CSTA III, Part 2, Version 4.1 Developer s Guide A31003-G9310-I200-1-76 Our Quality and Environmental Management Systems are implemented aording to the requirements

More information

Mega-Stor INSTALLATION AND OPERATING INSTRUCTIONS ENGINEERING MANUAL MAINTENANCE PARTS

Mega-Stor INSTALLATION AND OPERATING INSTRUCTIONS ENGINEERING MANUAL MAINTENANCE PARTS D E S I G N E D T O L E A D Mega-Stor TM Stainless Steel, Indirect Water Heaters INSTALLATION AND OPERATING INSTRUCTIONS ENGINEERING MANUAL MAINTENANCE PARTS CAUTION 1. having a toxicity rating or Class

More information

HEAT EXCHANGERS-2. Associate Professor. IIT Delhi E-mail: prabal@mech.iitd.ac.in. P.Talukdar/ Mech-IITD

HEAT EXCHANGERS-2. Associate Professor. IIT Delhi E-mail: prabal@mech.iitd.ac.in. P.Talukdar/ Mech-IITD HEA EXHANGERS-2 Prabal alukdar Assoiate Professor Department of Mehanial Engineering II Delhi E-mail: prabal@meh.iitd.a.in Multipass and rossflow he subsripts 1 and 2 represent the inlet and outlet, respetively..

More information

Installation and Operation Instructions Domestic hot water modules: FriwaMidi DN 20 FriwaMaxi DN 25

Installation and Operation Instructions Domestic hot water modules: FriwaMidi DN 20 FriwaMaxi DN 25 PAW GmbH & Co. KG Böcklerstr. 11, D-31789 Hameln, Germany Phone: +49-5151-9856-0, Fax: +49-5151-9856-98 E-mail: info@paw.eu, Web: www.paw.eu Installation and Operation Instructions Domestic hot water modules:

More information

Commercial Semi-Instantaneous Water Heaters

Commercial Semi-Instantaneous Water Heaters FEATURES HWI Models A. O. Smith s HWI models are available for operation with steam or boiler water as the energy source. They are factory assembled with components sized, piped and checked at the factory

More information

Tempra / DHC-E. Simply the Best 800.582.8423. The Finest Tankless Electric Water Heater Available! Featuring Advanced Microprocessor Control

Tempra / DHC-E. Simply the Best 800.582.8423. The Finest Tankless Electric Water Heater Available! Featuring Advanced Microprocessor Control ENGINEERING EXCELLENCE Simply the Best The Finest Tankless Electric Water Heater Available! Tempra / DHC-E Featuring Advanced Microprocessor Control Outperforms Bulky Hot Water Tanks Reduces Hot Water

More information

Range Tribune HE Solar Unvented Direct and Indirect Cylinders

Range Tribune HE Solar Unvented Direct and Indirect Cylinders Range Tribune HE Solar Unvented Direct and Indirect Cylinders Range Tribune HE Solar cylinders have been designed specifically with Solar applications in mind and are based on the highly successful Range

More information

THERM Tankless Water Heaters. Applications Manual

THERM Tankless Water Heaters. Applications Manual THERM Tankless Water Heaters Applications Manual 2 THERM Tankless Water Heater Applications Manual THERM Tankless Water Heater Applications Manual 3 Table of Contents 1 Introduction 4 2 Bosch THERM Model

More information

Thermostatic valve Type AVTA

Thermostatic valve Type AVTA MAKING MODERN LIVING POSSIBLE Data sheet Thermostatic valve Type AVTA Thermostatic valves are used for proportional regulation of flow quantity, depending on the setting and the sensor temperature. The

More information

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Technical Information sheet 0001/07/Rev01 ENG FUNCTION Series S001 and S002 circulation units are applied to the primary circuit of solar

More information

HL Series - Commercial Heaters Tankless Water Heating Solutions

HL Series - Commercial Heaters Tankless Water Heating Solutions HL Series - Commercial Heaters 5-18 kw (17,000-61,400 BTUs) Low flow activation options at.15 and.25 GPM (0.6 and 0.9 L-Min) Certified Lead-Free Design Variable Temp Heat Exchanger Pressure Drop Advantage

More information

THE PERFORMANCE OF TRANSIT TIME FLOWMETERS IN HEATED GAS MIXTURES

THE PERFORMANCE OF TRANSIT TIME FLOWMETERS IN HEATED GAS MIXTURES Proeedings of FEDSM 98 998 ASME Fluids Engineering Division Summer Meeting June 2-25, 998 Washington DC FEDSM98-529 THE PERFORMANCE OF TRANSIT TIME FLOWMETERS IN HEATED GAS MIXTURES John D. Wright Proess

More information

Installation & Operation Manual Models: STU150-940

Installation & Operation Manual Models: STU150-940 STU-I-O Rev B Installation & Operation Manual Models: STU150-940 IMG00044 LOW LEAD CONTENT WARNING This manual must only be used by a qualified heating installer / service technician. Read all instructions

More information

Findings and Recommendations

Findings and Recommendations Contrating Methods and Administration Findings and Reommendations Finding 9-1 ESD did not utilize a formal written pre-qualifiations proess for seleting experiened design onsultants. ESD hose onsultants

More information

In order to be able to design beams, we need both moments and shears. 1. Moment a) From direct design method or equivalent frame method

In order to be able to design beams, we need both moments and shears. 1. Moment a) From direct design method or equivalent frame method BEAM DESIGN In order to be able to design beams, we need both moments and shears. 1. Moment a) From diret design method or equivalent frame method b) From loads applied diretly to beams inluding beam weight

More information

FLASH TANK ECONOMIZER PRODUCT GUIDE

FLASH TANK ECONOMIZER PRODUCT GUIDE FLASH TANK ECONOMIZER PRODUCT GUIDE Overview A flash tank is used to recover blowdown energy in the form of flash steam and blowdown. This can only be used with a deaerator or some other pressurized device.

More information

Applications manual. For tankless and point-of-use water heaters

Applications manual. For tankless and point-of-use water heaters Applications manual For tankless and point-of-use water heaters 2 Bosch applications manual Bosch applications manual 3 Table of Contents 1 Introduction 4 2 Bosch Water Heating Model Certifications 4 3

More information

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS Electronic thermostatically controlled Low power consumption Compact space saving size Short heat-up times Dehumidification of the cabin Quiet when running Combustion

More information

Air Eliminators and Combination Air Eliminators Strainers

Air Eliminators and Combination Air Eliminators Strainers Description Air Eliminators and Combination Air Eliminator Strainers are designed to provide separation, elimination and prevention of air in piping systems for a variety of installations and conditions.

More information

Installation and maintenance instructions

Installation and maintenance instructions Installation and maintenance instructions Indirect fired domestic hot water tank Logalux ST50/ ST300/ For heating contractors Please read carefully prior to installation and maintenance. 7 747 00 883 09/006

More information

Trin & Stor Model Numbers: S, S-SR, SL Series Version Date: 2014-08-06

Trin & Stor Model Numbers: S, S-SR, SL Series Version Date: 2014-08-06 Trin & Stor Model Numbers: S, S-SR, SL Series Version Date: 2014-08-06 NEW PRODUCT LINE Stainless Steel Stainless Steel Solar Stone Lined INDIRECT WATER HEATERS INSTALLATION AND OPERATION INSTRUCTIONS

More information

REGULATORS 175/153 Series

REGULATORS 175/153 Series 175/153 Series 175 HEATING 153 COOLING Watson McDaniel reserves the right to change the designs and/or materials of its products without notice. 2002 Watson McDaniel Company Revised 7/2002 175 / 153 Screwed

More information

Modulex. Gas Fired Boiler Systems PIPING GUIDE GF-115-P. Modular, Condensing, Hot Water Boilers Models: 303, 454, 606, 757, 909, 1060. Instruction No.

Modulex. Gas Fired Boiler Systems PIPING GUIDE GF-115-P. Modular, Condensing, Hot Water Boilers Models: 303, 454, 606, 757, 909, 1060. Instruction No. Instruction No. AERCO INTERNATIONAL, Inc., Northvale, New Jersey, 07647 USA PIPING GUIDE GF-115-P Modulex Gas Fired Boiler Systems Modular, Condensing, Hot Water Boilers Models: 303, 454, 606, 757, 909,

More information

Cooking at the Speed of light!

Cooking at the Speed of light! Cooking at the Infrared Cooking & Colouring Infrabaker is a modular infrared continuous cooking system developed by Infrabaker International. The machine is designed to cook and/or put colour on a wide

More information

VITOSOL r 200-T SP2A. VITOSOL 200-T Type SP2A

VITOSOL r 200-T SP2A. VITOSOL 200-T Type SP2A Technical Data Manual Model Nos. and pricing: see Price List Vacuum tube collector based on the heat pipe principle For the utilisation of solar energy VITOSOL r 200-T SP2A Product may not be exactly as

More information

Therm-Omega-Tech, Inc. Therm-Omega-Tech, Inc. MODEL EMV. A Heavy Duty, Reliable Source For Tepid Water Delivery. Model EMV

Therm-Omega-Tech, Inc. Therm-Omega-Tech, Inc. MODEL EMV. A Heavy Duty, Reliable Source For Tepid Water Delivery. Model EMV MODEL EMV Emergency Safety Shower Water Heater Tepid Water For Emergency Safety Shower/Eyewash Stations Features Heavy Duty Construction Hydrastone cement lining provides tank longevity Copper-silicon

More information

USER MANUAL INSTALLATION INSTRUCTION WARRANTY REGISTER. Free Hot Water Solar Storage Tank (SST) with Single/Double coil heat exchanger

USER MANUAL INSTALLATION INSTRUCTION WARRANTY REGISTER. Free Hot Water Solar Storage Tank (SST) with Single/Double coil heat exchanger Installer / Service Provider details USER MANUAL INSTALLATION INSTRUCTION WARRANTY REGISTER Free Hot Water Solar Storage Tank (SST) with Single/Double coil heat exchanger Customer / User Congratulations

More information

The NEW Greenstar i. intuitive. innovative. improved performance. installation ease

The NEW Greenstar i. intuitive. innovative. improved performance. installation ease The NEW Greenstar i innovative intuitive improved performance installation ease A NEW look, NEW features and a NEW NAME for the UK s best selling boiler, the Greenstar i Junior 1 Introducing the new Greenstar

More information

Electrician'sMathand BasicElectricalFormulas

Electrician'sMathand BasicElectricalFormulas Eletriian'sMathand BasiEletrialFormulas MikeHoltEnterprises,In. 1.888.NEC.CODE www.mikeholt.om Introdution Introdution This PDF is a free resoure from Mike Holt Enterprises, In. It s Unit 1 from the Eletrial

More information

Annual Return/Report of Employee Benefit Plan

Annual Return/Report of Employee Benefit Plan Form 5500 Department of the Treasury Internal Revenue Servie Department of Labor Employee Benefits Seurity Administration Pension Benefit Guaranty Corporation Annual Return/Report of Employee Benefit Plan

More information

Data Sheet VITOSOL 100. Flat collectors for the utilisation of solar energy. Vitosol 100. Part nos. and prices: see price list

Data Sheet VITOSOL 100. Flat collectors for the utilisation of solar energy. Vitosol 100. Part nos. and prices: see price list VITOSOL 100 Flat collectors for the utilisation of solar energy Data Sheet Part nos. and prices: see price list File in: Vitotec 1 Manual, Index 16 Vitosol 100 Type s 1.7 Vitosol 100 Type s 2.5 Vitosol

More information

Vitodens 200, B2HA / B2HB - Product Introduction

Vitodens 200, B2HA / B2HB - Product Introduction - Product Introduction Foil 2, 10/2015 Viessmann Manufacturing Wall Mounted, Gas-Fired Condensing Boiler Foil 3, 10/2015 Viessmann Manufacturing A member of the Viessmann family of heating products Condensing

More information

Modern Gas Heating. The Vitodens 200 gas-fired condensing boiler is prepared for the use of conditioned biogas.

Modern Gas Heating. The Vitodens 200 gas-fired condensing boiler is prepared for the use of conditioned biogas. Heating with Gas Modern Gas Heating With fluctuating energy prices and a growing concern for the environment, it pays to modernize your outdated gas-fired boiler. You will save money, and the environment

More information

i e SD No. 2016/0058 HARBOUR DUES (MERCHANT VESSELS) REGULATIONS 2016

i e SD No. 2016/0058 HARBOUR DUES (MERCHANT VESSELS) REGULATIONS 2016 i e SD No. 2016/0058 HARBOUR DUES (MERCHANT VESSELS) REGULATIONS 2016 Harbour Dues (Merhant Vessels) Regulations 2016 Index HARBOUR DUES (MERCHANT VESSELS) REGULATIONS 2016 Index Regulation Page 1 Title...

More information

Chapter 1 Microeconomics of Consumer Theory

Chapter 1 Microeconomics of Consumer Theory Chapter 1 Miroeonomis of Consumer Theory The two broad ategories of deision-makers in an eonomy are onsumers and firms. Eah individual in eah of these groups makes its deisions in order to ahieve some

More information

Measurement of Powder Flow Properties that relate to Gravity Flow Behaviour through Industrial Processing Lines

Measurement of Powder Flow Properties that relate to Gravity Flow Behaviour through Industrial Processing Lines Measurement of Powder Flow Properties that relate to Gravity Flow ehaviour through Industrial Proessing Lines A typial industrial powder proessing line will inlude several storage vessels (e.g. bins, bunkers,

More information

HYDROSTATIC TEST PUMPS

HYDROSTATIC TEST PUMPS HYDROSTATIC TEST PUMPS MANUAL HYDROSTATIC TEST PUMPS Ideal for testing residential water lines. Also for pressure testing small pressure tanks, sprinkler, boiler and solar systems. Lightweight and easy

More information

Supply chain coordination; A Game Theory approach

Supply chain coordination; A Game Theory approach aepted for publiation in the journal "Engineering Appliations of Artifiial Intelligene" 2008 upply hain oordination; A Game Theory approah Jean-Claude Hennet x and Yasemin Arda xx x LI CNR-UMR 668 Université

More information

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling Water Fired Chiller/Chiller-Heater WFC-S Series: 1, 2 and 3 RT Cooling W E A R E F R I E N D L Y T O T H E E A R T H Water Fired SINGLE-EFFECT Chiller or Chiller-Heater Absorption Principle Cooling Cycle

More information

Technical Data Manual Model Nos. and pricing: see Price List. VITODENS r 222-F

Technical Data Manual Model Nos. and pricing: see Price List. VITODENS r 222-F Technical Data Manual Model Nos. and pricing: see Price List For Natural Gas and Liquid Propane Gas Gas-fired floor-mounted condensing DHW combi-boiler 12 to 125 MBH (3.5 to 37 kw) VITODENS r 222-F Product

More information

STATIONARY WATER HEATERS

STATIONARY WATER HEATERS OPERATING AND INSTALLATION MANUAL STATIONARY WATER HEATERS OKCE 100 NTR / 2,2 kw OKCE 125 NTR / 2,2 kw OKCE 160 NTR / 2,2 kw OKCE 200 NTR / 2,2 kw OKCE 250 NTR / 2,2 kw OKCE 300 NTR / 2,2 kw OKCE 300 NTR

More information

model 1900 FEATURES & BENEFITS SPECIFICATIONS APPLICATIONS OPTIONS Bottle Filler

model 1900 FEATURES & BENEFITS SPECIFICATIONS APPLICATIONS OPTIONS Bottle Filler model Bottle Filler FEATUES & BENEFITS UNIVESAL MOUNTING This unit is perfect as a stand-alone bottle filling station, or easily located over virtually any wall mounted drinking fountain or water cooler

More information

Technical Data Manual Model Nos. and pricing: see Price List. VITODENS r 222-F

Technical Data Manual Model Nos. and pricing: see Price List. VITODENS r 222-F Technical Data Manual Model Nos. and pricing: see Price List For Natural Gas and Liquid Propane Gas Gas-fired floor-mounted condensing DHW combi-boiler 12 to 125 MBH (3.5 to 37 kw) VITODENS r 222-F Product

More information

Customer Reporting for SaaS Applications. Domain Basics. Managing my Domain

Customer Reporting for SaaS Applications. Domain Basics. Managing my Domain Produtivity Marketpla e Software as a Servie Invoiing Ordering Domains Customer Reporting for SaaS Appliations Domain Basis Managing my Domain Managing Domains Helpful Resoures Managing my Domain If you

More information

Natural geothermal energy.

Natural geothermal energy. ROTEX ground source heat pump Natural geothermal energy. ROTEX HPU ground the ground source heat pump that heats with free geothermal energy. Compact, environmentally responsible and uniquely efficient.

More information

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters FEATURES ULTRA-LOW NOx CONDENSING TECHNOLOGY PROVIDES UNPRECEDENTED 0.95 ENERGY FACTOR DURABLE HEAT EXCHANGER Primary Heat Exchanger

More information

Income Protection CLAIM FORM

Income Protection CLAIM FORM Inome Protetion CLAIM FORM PLEASE COMPLETE THIS APPLICATION IN BLACK PEN ONLY USING BLOCK LETTERS 1 PERSONAL DETAILS Poliy numer Important notes: a This form must e ompleted in full and returned to PO

More information

MAKING MODERN LIVING POSSIBLE. Thermostatic valve AVTA. Technical brochure

MAKING MODERN LIVING POSSIBLE. Thermostatic valve AVTA. Technical brochure MAKING MODERN LIVING POSSIBLE Thermostatic valve AVTA Technical brochure 2 IC.PD.500.A3.02-520B3728 Danfoss A/S 07-2009/ RA-MC/mr Contents Page Features............................................................................................4

More information

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS Replacement parts DO NOT SERVICE THE BOILER WITHOUT A WM97+ MAINTENANCE KIT AVAILABLE Failure to adhere to these guidelines can result in severe personal injury, death or substantial property damage. The

More information

Commercial Gas Water Heaters

Commercial Gas Water Heaters UP TO 96% THERMAL EFFICIENCY, DIRECT-VENT FEATURES TM BTH-120 through BTH-500 The A. O. Smith Cyclone Xi family of products represents the industry s most technologically advanced commercial water heaters.

More information

ITE. Indirect calorifier ITE - 400/500/600/750/1000. Installation, User and Service Manual. Innovation has a name.

ITE. Indirect calorifier ITE - 400/500/600/750/1000. Installation, User and Service Manual. Innovation has a name. ITE Indirect calorifier ITE - 400/500/600/750/1000 0310 117 Installation, User and Service Manual Innovation has a name. Read this manual carefully Warning Read this manual carefully before starting the

More information

Section 43. Lead Paint Risk Factor NONE WATER HEATER STORAGE ELECTRIC

Section 43. Lead Paint Risk Factor NONE WATER HEATER STORAGE ELECTRIC WATER HEATER STORAGE ELECTRIC Lead Paint Risk Factor NONE TABLE OF CONTENTS PART 1: INSTALLATION REQUIREMENTS FOR CONVENTIONAL HOMES... 1 WATER HEATER REPAIRS... 1 1. APPLIANCE REPAIR... 1 WATER HEATER

More information

Commercial Storage Tanks

Commercial Storage Tanks Commercial Storage Tanks ALL THE STORAGE CHOICES YOU NEED FOR A TOTAL HOT WATER SUPPLY SYSTEM. INNOVATION AT A GLANCE A. O. SMITH IS THE BEST CHOICE FOR COMPLETE COMMERCIAL WATER HEATING AND STORAGE SYSTEMS

More information

VIESMANN. Datasheet Part numbers and prices: see pricelist VITOSOL 200-F. Flat-plate collector for the utilisation of solar energy

VIESMANN. Datasheet Part numbers and prices: see pricelist VITOSOL 200-F. Flat-plate collector for the utilisation of solar energy VIESMANN VITOSOL 200-F Flat-plate collector for the utilisation of solar energy Datasheet Part numbers and prices: see pricelist File in: Vitotec folder, register 13 VITOSOL 200-F Type SV2 and SH2 Flat-plate

More information

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing) CHRONOMITE INSTANT-FLOW MICRO WATER HEATER INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) TABLE 1 Model No.

More information

SOLAR HEATING SYSTEMS. www.orkli.com

SOLAR HEATING SYSTEMS. www.orkli.com SOLAR HEATING SYSTEMS www.orkli.com // 2 Orkli is one of the main European manufacturers of components for household appliances and innovative solutions for the comfort sector. Its corporate activity is

More information

Technical Data Manual Model Nos. and pricing: see Price List. VITODENS r 200-W

Technical Data Manual Model Nos. and pricing: see Price List. VITODENS r 200-W Technical Data Manual Model Nos. and pricing: see Price List Gas-fired wall-mounted condensing boiler 71 to 530 MBH (21 to 155 kw) Multi-boiler installation 71 to 4240 MBH (21 to 1240 kw) For Natural Gas

More information

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS Electronic thermostatically controlled Low power consumption Compact space saving size Short heat-up times Dehumidification of the cabin Quiet when running Combustion

More information

Technical Data Manual Model Nos. and pricing: see Price List. VITODENS r 222-F

Technical Data Manual Model Nos. and pricing: see Price List. VITODENS r 222-F Technical Data Manual Model Nos. and pricing: see Price List For Natural Gas and Liquid Propane Gas Gas-fired floor-mounted condensing DHW combi-boiler 12 to 125 MBH (3.5 to 37 kw) VITODENS r 222-F Product

More information

Commercial Electric Water Heater

Commercial Electric Water Heater Commercial Electric Water Heater Provides Tepid Water For Emergency Fixtures Features Heavy Duty Construction Hydrastone cement lining provides tank longevity Copper-silicon alloy tappings cannot rust

More information

Trin & Stor Model Numbers: ST Series Version Date: 2012-04-19

Trin & Stor Model Numbers: ST Series Version Date: 2012-04-19 Trin & Stor Model Numbers: ST Series Version Date: 2012-04-19 NEW PRODUCT LINE Storage Tanks Stainless Steel Tank TPI Thermostat STORAGE TANK INSTALLATION AND OPERATION INSTRUCTIONS Storage companion to

More information

Equivalents & Conversion Factors 406 Capacity Formulas for Steam Loads 407 Formulas for Control Valve Sizing 408-409

Equivalents & Conversion Factors 406 Capacity Formulas for Steam Loads 407 Formulas for Control Valve Sizing 408-409 Engineering Data Table of Contents Page No. I II Formulas, Conversions & Guidelines Equivalents & Conversion Factors 406 Capacity Formulas for Steam Loads 407 Formulas for Control Sizing 408-409 Steam

More information

Solar SOLARMAX ELECTRIC BOOSTED SPECIFICATIONS ALL AUSSIE GAS & ELECTRIC BOOSTED SOLAR WATER HEATERS

Solar SOLARMAX ELECTRIC BOOSTED SPECIFICATIONS ALL AUSSIE GAS & ELECTRIC BOOSTED SOLAR WATER HEATERS Solar MAX ELECTRIC BOOSTED SPECIFICATIONS Proudly Australian ALL AUSSIE GAS & ELECTRIC BOOSTED WATER S Harness the power of the Sun. 1 Energy efficiency that s out of this world AquaMAX high efficiency

More information

' R ATIONAL. :::~i:. :'.:::::: RETENTION ':: Compliance with the way you work PRODUCT BRIEF

' R ATIONAL. :::~i:. :'.:::::: RETENTION ':: Compliance with the way you work PRODUCT BRIEF ' R :::i:. ATIONAL :'.:::::: RETENTION ':: Compliane with the way you work, PRODUCT BRIEF In-plae Management of Unstrutured Data The explosion of unstrutured data ombined with new laws and regulations

More information

Daikin Altherma hybrid heat pump. The natural combination

Daikin Altherma hybrid heat pump. The natural combination Daikin Altherma hybrid heat pump The natural combination Daikin Altherma hybrid heat pump, the natural combination Why choose Daikin Altherma hybrid heat pump? What the customer wants: more energy efficient

More information

In-Line Air Separators

In-Line Air Separators Air Elimination & Control In-Line Air Separators The AC models of air separators deliver all the quality and performance you expect from Taco products. They are built to last with shell, heads and ANSI

More information

Installation & Operation Manual Models: SIT030 - SIT119

Installation & Operation Manual Models: SIT030 - SIT119 SIT-I-O Rev K Installation & Operation Manual Models: SIT030 - SIT119 CAUTION: The heat transfer medium must be water or other nontoxic fluid having a toxicity rating or class of 1, as listed in Clinical

More information

INCOME TAX WITHHOLDING GUIDE FOR EMPLOYERS

INCOME TAX WITHHOLDING GUIDE FOR EMPLOYERS Virginia Department of Taxation INCOME TAX WITHHOLDING GUIDE FOR EMPLOYERS www.tax.virginia.gov 2614086 Rev. 01/16 Table of Contents Introdution... 1 Important... 1 Where to Get Assistane... 1 Online File

More information

) ( )( ) ( ) ( )( ) ( ) ( ) (1)

) ( )( ) ( ) ( )( ) ( ) ( ) (1) OPEN CHANNEL FLOW Open hannel flow is haraterized by a surfae in ontat with a gas phase, allowing the fluid to take on shapes and undergo behavior that is impossible in a pipe or other filled onduit. Examples

More information

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A Bulletin 20-20.2 / July 2012 M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A ➀ ➁ ➂ Model Number Key M 2430 C L 1 - A - ➀ Unit Type M=Modular Nominal Capacity 2430=24000 to 30000

More information

Advanced Heating & Hot Water Systems. Ultra High Efficiency Energy Star Listed Condensing Boiler

Advanced Heating & Hot Water Systems. Ultra High Efficiency Energy Star Listed Condensing Boiler Advanced Heating & Hot Water Systems A Trailblazing Energy Star Listed Boiler that Installs like a Mid-Efficiency Boiler with the Performance of a High-Efficiency Product Ultra High Efficiency Energy Star

More information

Intelligent Measurement Processes in 3D Optical Metrology: Producing More Accurate Point Clouds

Intelligent Measurement Processes in 3D Optical Metrology: Producing More Accurate Point Clouds Intelligent Measurement Proesses in 3D Optial Metrology: Produing More Aurate Point Clouds Charles Mony, Ph.D. 1 President Creaform in. mony@reaform3d.om Daniel Brown, Eng. 1 Produt Manager Creaform in.

More information

LAKE COUNTY ANIMAL SERVICES EXPANSION SECTION 15459

LAKE COUNTY ANIMAL SERVICES EXPANSION SECTION 15459 SECTION 15459 PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division-1 Specification sections, apply to work

More information

BUILDING CODE SUMMARY GENERAL NOTES DESIGN BUILD ELECTRICAL DESIGN BUILD MECHANICAL & PLUMBING GENERAL NOTES GENERAL NOTES G101

BUILDING CODE SUMMARY GENERAL NOTES DESIGN BUILD ELECTRICAL DESIGN BUILD MECHANICAL & PLUMBING GENERAL NOTES GENERAL NOTES G101 D D BUILDING CODE SUMMARY GENERAL NOTES PROJECT DESCRIPTION: THIS PROJECT IS THE MINOR RENOVATION OF AN EXISTING OUTPATIENT CLINIC. SCOPE CONSISTS OF PAINT, CARPET, TILE, AND UPGRADE TO DIGITAL X-RAY BUILDING

More information

INCOME TAX WITHHOLDING GUIDE FOR EMPLOYERS

INCOME TAX WITHHOLDING GUIDE FOR EMPLOYERS Virginia Department of Taxation INCOME TAX WITHHOLDING GUIDE FOR EMPLOYERS www.tax.virginia.gov 2614086 Rev. 07/14 * Table of Contents Introdution... 1 Important... 1 Where to Get Assistane... 1 Online

More information

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL EEMAX ELECTRIC TANKLESS WATER HEATERS IMPORTANT SAFETY INFORMATION

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL EEMAX ELECTRIC TANKLESS WATER HEATERS IMPORTANT SAFETY INFORMATION INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL EEMAX ELECTRIC TANKLESS WATER HEATERS IMPORTANT SAFETY INFORMATION When installing or using any high voltage electrical appliance, basic safety precautions

More information