Technical Data Manual Model Nos. and pricing: see Price List
|
|
- Egbert Miller
- 7 years ago
- Views:
Transcription
1 Tehnial Data Manual Model Nos. and priing: see Prie List Vitoell 100-V CVAA and CVA Series Indiret-fired domesti hot water storage tank 42 USG to 119 USG (160 L to 450 L) apaity Indiret-fired domesti hot water storage tank steel onstrution, with Ceraprotet enamel oating. Produt may not be exatly as shown CAUTION This tank version is not suitable for steam heating appliations. 12/2015
2 Produt Information Benefits Vitoell 100-V, CVA/CVAA Series Tehnial Data The vertial tank solution for ost-effiient domesti hot water supply. The Vitoell 100-V DHW tank offers storage apaities of up to 119 USG (450 L). Benefits at a glane: Corrosion-proteted steel tank shell with Ceraprotet enamel oating. Magnesium anode provides additional athodi tank protetion. Heat exhanger oil extends to the bottom of the tank, thereby heating the entire water ontent. Extremely onvenient domesti hot water supply assured by fast, uniform heating via generously sized heat exhanger surfaes. Certified to CSA Low Lead Content Certifiation Program; inluding US Safe Drinking Water At, NSF/ANSI 372 as well as other appliable US State requirements. Universally suitable - for appliations requiring larger quantities of hot water, multiple Vitoell 100-V tanks may be onneted to a header to form a tank battery. Inreased energy savings thanks to highly effetive, foamed-in-plae HCFC-free insulation keeping standby losses at a minimum. The vitoell-v USG (450 L) apaity tank is supplied with removable soft PET insulation for easier handling. 2
3 Vitoell 100-V, CVA/CVAA Series Tehnial Data Cross Setion Produt Information 3
4 Tehnial Data Tehnial Data Vitoell 100-V, CVA/CVAA Series Tehnial Data For domesti hot water heating appliations in onjuntion with hot water heating boilers Suitable for heating systems with: max. working pressure on the heat exhanger side of up to 150 psig (10 bar) max. working pressure on DHW side of up to 150 psig (10 bar) max. supply temperature on the heat exhanger side of up to 230 F (110 C) max. DHW supply temperature of up to 150 F (65.6 C) Tank series CVA CVA CVAA CVA Storage apaity USG (L) 42 (160) 53 (200) 79 (300) 119 (450) Reovery rates*1 MBH (kw) 136 (40) 136 (40) 180 (53) 238 (70) 194ºF (90ºC) with a DHW temperature GPH (L/h) 258 (982) 258 (982) 342 (1302) 456 (1720) inrease from 50 to 113ºF MBH (kw) 109 (32) 109 (32) 150 (44) 198 (58) 176ºF (80ºC) (10 to 45ºC) and a supply water GPH (L/h) 210 (786) 210 (786) 288 (1081) 378 (1425) temperature of... MBH (kw) 85 (25) 85 (25) 113 (33) 153 (45) 158ºF (70ºC) GPH (L/h) 162 (614) 162 (614) 216 (811) 294 (1106) MBH (kw) 58 (17) 58 (17) 78 (23) 109 (32) 140ºF (60ºC) GPH (L/h) 108 (417) 108 (417) 149 (565) 210 (786) MBH (kw) 31 (9) 31 (9) 61 (18) 82 (24) 122ºF (50ºC) GPH (L/h) 60 (221) 60 (221) 114 (442) 156 (589) Reovery rates*1 MBH (kw) 123 (36) 123 (36) 153 (45) 181 (53) 194ºF (90ºC) with a DHW temperature GPH (L/h) 164 (619) 164 (619) 204 (774) 240 (911) inrease from 50 to 140ºF MBH (kw) 95 (28) 95 (28) 116 (34) 150 (44) 176ºF (80ºC) (10 to 60ºC) and a supply water GPH (L/h) 120 (482) 120 (482) 156 (584) 198 (756) temperature of... MBH (kw) 65 (19) 65 (19) 78 (23) 113 (33) 158ºF (70ºC) GPH (L/h) 84 (327) 84 (327) 102 (395) 150 (567) Supply flow rate for the reovery rates stated GPM (m 3/ h) 13.2 (3.0) 13.2 (3.0) 13.2 (3.0) 13.2 (3.0) Insulation PUR Foam PUR Foam PUR Foam Soft PET Standby losses*2 MBH/24 h *1 When planning for the reovery rate as stated or alulated, allow for the orresponding irulation pump. The stated reovery rate is only ahieved when the rated output of the boiler is equal to or greater than that stated under Reovery rate. Please also refer to the orresponding sizing hart at the end of this manual. *2 Measured values are based on a room temp. of 68 F (20ºC) and a domesti hot water temp. of 149 F (65ºC) and an vary by 5%. *3 For other dimensions, see illustration and table on page 5. *4 Adjustable feet an be adjusted up to 2 in. (50 mm). For information regarding other Viessmann System Tehnology omponentry, please referene the doumentation of the respetive produt. 4 Dimensions *3 Tank length without insulation Overall length with insulation Tank width without insulation Overall width with insulation Tank height without insulation Overall height with insulation*4 Tilt height without insulation Tilt height with insulation 23 (581) 24 (605) 47 (1189) 50 (1260) 23 (581) 24 (605) 55b (1409) 57b (1460) 26a (667) 29a (744) 68a (1734) 72 (1825) 34 (859) 33 (837) 36a (923) 76 (1948) 72b (1844) 73a (1860) Weight Tank with insulation lbs (kg) 190 (86) 214 (97) 333 (151) 399 (181) Heat exhanger oil liquid ontent USG (L) 1.45 (5.5) 1.45 (5.5) 2.6 (10) 3.3 (12.5) Heat exhanger surfae area ft. 2 (m 2 ) 10.8 (1) 10.8 (1) 16.1 (1.5) 20.5 (1.9) Connetions Heating water supply/return Domesti old/hot water T&P valve Reirulation in. (male NPT thread) in. (male NPT thread) in. (female NPT thread) in. (male NPT thread) a 1
5 Vitoell 100-V, CVA/CVAA Series Tehnial Data CVA 42 and 53 USG (160 and 200 L) Tank Dimensions Tehnial Data Dimensions Storage apaity b d e f h USG (L) 42 (160) 53 (200) 2 (72) 9 (249) 25 (634) 35 (884) 41 (1050) 12b (317) 2 (72) 9 (249) 25 (634) 35 (884) 41 (1050) 12b (317) Legend IO Inspetion and lean-out opening D Drain BWR Boiler water return (upper oil) BWS Boiler water supply (upper oil) DCW Domesti old water AQ Aquastat well (at the same height as the boiler water supply onnetion) DHW Domesti hot water RT Reirulation tapping TPV Temperature and pressure relief valve MA Protetive magnesium anode 5
6 Tehnial Data CVAA 79 USG (300 L) Tank Dimensions Vitoell 100-V, CVA/CVAA Series Tehnial Data Dimensions Storage apaity USG (L) 79 (300) a b d e f g h j 13 (333) 3 (76) 10 (260) 34b (875) 44 (1115) 63 (1600) 26 (660) 14a (361) 4 (100) Legend IO Inspetion and lean-out opening D Drain BWR Boiler water return (upper oil) BWS Boiler water supply (upper oil) DCW Domesti old water AQ Aquastat well (at the same height as the boiler water supply onnetion) DHW Domesti hot water RT Reirulation tapping TPV Temperature and pressure relief valve MA Protetive magnesium anode 6
7 Vitoell 100-V, CVA/CVAA Series Tehnial Data CVA 119 USG (450 L) Tank Dimensions Tehnial Data Dimensions Storage apaity USG (L) 119 (450) a b d e f g h j 16b (422) 4 (100) 13 (349) 36a (924) 48b (1230) 70a (1784) 33 (837) 18 (455) 4 (100) Legend IO Inspetion and lean-out opening D Drain BWR Boiler water return (upper oil) BWS Boiler water supply (upper oil) DCW Domesti old water AQ Aquastat well (at the same height as the boiler water supply onnetion) DHW Domesti hot water RT Reirulation tapping TPV Temperature and pressure relief valve MA Protetive magnesium anode 7
8 Tehnial Data Water Flow Vitoell 100-V, CVA/CVAA Series Tehnial Data Domesti hot water draw rate Storage tank ontents heated to 140ºF (60ºC), boiler not reheating Storage apaity USG (L) 42 (160) 53 (200) 79 (300) 119 (450) Domesti draw rate GPM (L/min) 2.6 (10) 2.6 (10) 4.0 (15) 4.0 (15) Domesti hot water draw Water with t = 140ºF (60ºC) (onstant) USG (L) 32 (120) 38 (145) 63 (240) 111 (420) Perentage tank volume % Heat-up time The stated heating times are ahieved when the maximum reovery rate of the domesti hot water tank is made available at the respetive supply temperature and with a domesti hot water rise from 50 to 140 F (10 to 60 C). Storage apaity USG (L) 42 (160) 53 (200) 79 (300) 119 (450) Heating water supply temperature 194 F (90 C) 176 F (80 C) 158 F (70 C) Heat-up time (minutes) Pressure drop on heating water side (primary iruit) Pressure drop on domesti hot water side (seondary iruit) Legend A 42 USG (160 L) and 53 USG (200 L) storage apaities B 79 USG (300 L) storage apaity C 119 USG (450 L) storage apaity 8
9 Vitoell 100-V, CVA/CVAA Series Tehnial Data Multiple Tank Installation Produt Installation Tehnial Data The 79 and 119 USG (300 and 450 L) tank sizes may be ombined into a battery onsisting of between 2 and 3 tanks. Tank batteries onsisting of more than 3 tanks an be installed by reating up to 4 batteries, eah onsisting of 3 tanks. The heating ontrator is responsible to ensure proper piping on both the primary and seondary iruits. Tank series CVAA CVA Storage apaity USG (L) 79 (300) 119 (450) Total apaity of tank battery USG (L) 159 (600) 238 (900) 357 (1350) Number of storage tanks Reovery rates*1 with a DHW temperature inrease from 50 to 113ºF (10 to 45ºC) and a supply water temperature of... Reovery rates*1 with a DHW temperature inrease from 50 to 140ºF (10 to 60ºC) and a supply water temperature of... MBH (kw) 194ºF (90ºC) GPH (L/h) MBH (kw) 176ºF (80ºC) GPH (L/h) MBH (kw) 158ºF (70ºC) GPH (L/h) MBH (kw) 140ºF (60ºC) GPH (L/h) MBH (kw) 122ºF (50ºC) GPH (L/h) MBH (kw) 194ºF (90ºC) GPH (L/h) MBH (kw) 176ºF (80ºC) GPH (L/h) MBH (kw) 158ºF (70ºC) GPH (L/h) 361 (106) 690 (2604) 300 (88) 570 (2162) 225 (66) 426 (1622) 157 (46) 300 (1130) 123 (36) 234 (884) 307 (90) 408 (1548) 232 (68) 306 (1168) 157 (46) 210 (790) 477 (140) 906 (3440) 396 (116) 750 (2850) 307 (90) 582 (2212) 218 (64) 414 (1572) 164 (48) 312 (1178) 361 (106) 480 (1822) 300 (88) 402 (1512) 225 (66) 300 (1134) 716 (210) 1362 (5160) 593 (174) 1128 (4275) 460 (135) 876 (3318) 327 (96) 624 (2358) 246 (72) 468 (1767) 542 (159) 720 (2733) 450 (132) 600 (2268) 338 (99) 450 (1701) Supply flow rate for the reovery rates stated GPM (m 3/h ) 26.4 (6) 26.4 (6) 39.6 (9) Standby losses*2 MBH/24 h Dimensions Tank length without insulation Overall length with insulation Tank width without insulation Overall width with insulation Tank height without insulation Overall height with insulation Weight 57b (1495) 43b (1148) 69 (1734) 72b (1838) 48 (1218) 77 (1955) 111a (2826) 48 (1218) 77 (1955) Tank with insulation lbs (kg) 736a (334) 932 (423) 1409 (639) Heating water ontent USG (L) 6b (25) 8b (32) 13 (50) (heat exhanger pipe oil) Heat exhanger surfae area ft. 2 (m 2 ) 32a (3.0) 42 (3.9) 62b (5.8) *1 When planning for the reovery rate as stated or alulated, allow for the orresponding irulation pump. The stated reovery rate is only ahieved when the rated output of the boiler is equal to or greater than that stated under Reovery rate. Please also refer to the orresponding sizing hart at the end of this manual. *2 Measured values are based on a room temperature of 68 F (20ºC) and a domesti hot water temperature of 149 F (65ºC) and an vary by 5%. 9
10 Produt Installation Multiple Tank Installation (ontinued) Vitoell 100-V, CVA/CVAA Series Tehnial Data For domesti hot water appliations whih utilize modulating and low temperature hot water heating boilers or remote heating plants. 3 tanks 2 tanks Legend IO Inspetion and lean-out opening D Drain A Air vent BWR Boiler water return BWS Boiler water supply DCW Domesti old water DHW Domesti hot water RT Reirulation tapping TPV T&P valve top view Dimensions Tank series CVAA CVA Storage apaity 79 (300) 119 (450) Total apaity of battery USG (L) 159 (600) 238 (900) 357 (1350) Number of storage tanks USG (L) a b d e f 3 (76) 10a (260) 34b (875) 68a (1734) 14a (361) 8 (206) 4a (107) 13 (349) 36a (924) 70a (1948) 18 (455) 12b (320) 4a (107) 13 (349) 36a (924) 70a (1948) 18 (455) 12b (320) 10
11 Vitoell 100-V, CVA/CVAA Series Tehnial Data Multiple Tank Installation (ontinued) Produt Installation Domesti hot water draw rate Storage tank ontents heated to 140ºF (60ºC) Tank series CVAA CVA Storage apaity USG (L) 79 (300) 119 (450) Battery storage apaity USG (L) 159 (600) 238 (900) 357 (1350) Number of storage tanks Domesti draw rate GPM (L/min) 7.9 (30) 7.9 (30) 7.9 (30) Domesti hot water draw Water with t = 140ºF (60ºC) (onstant) USG (L) 127 (480) 222 (840) 333 (1260) Perentage tank volume % Quik reovery (over 10-minute period) Domesti hot water rise from 50 to 113 F (10 to 45 C) Tank series CVAA CVA Storage apaity USG (L) 79 (300) 119 (450) Battery storage apaity USG (L) 159 (600) 238 (900) 357 (1350) Number of storage tanks Heating water supply temperature 194 F (90 C) 176 F (80 C) 158 F (70 C) USG/10 min (L/10 min) USG/10 min (L/10 min) USG/10 min (L/10 min) Quik DHW reovery (over 10-minute period) 201 (759) 197 (745) 192 (728) 304 (1150) 287 (1088) 268 (1016) 425 (1610) 401 (1520) 370 (1400) Max. domesti hot water draw rate (over 10-minute period) Domesti hot water rise from 50 to 113 F (10 to 45 C) Tank series CVAA CVA Storage apaity USG (L) 79 (300) 119 (450) Battery storage apaity USG (L) 159 (600) 238 (900) 357 (1350) Number of storage tanks Heating water supply temperature 194 F (90 C) 176 F (80 C) 158 F (70 C) GPM (L/min) GPM (L/min) GPM (L/min) Max. DHW draw rate (over 10-minute period) 20.1 (76) 20 (74) 19.3 (73) 30 (115) 29 (109) 27 (102) 43 (161) 40 (152) 37 (140) 11
12 Produt Installation Standard Equipment Vitoell 100-V, CVA/CVAA Series Tehnial Data This is a simplified oneptual drawing only! Piping and neessary omponentry must be field verified. Proper installation and funtionality in the field is the responsibility of the heating ontrator. Legend A Domesti hot water supply B DHW reirulation line C DHW reirulation pump D Spring-loaded flow hek valve E Disharge pipe F Temperature and pressure relief valve (TPV) G Shut-off valve H Drain K Domesti old water supply lines L Bakflow preventer M Domesti old water inlet N Preharged expansion tank (required where bakflow preventer is installed; hek loal plumbing odes and requirements) O Thermostati mixing valve/anti-sald valve for solar appliations (field supplied) Vitoell 100-V 42 to 79 USG (160 to 300 L) apaity Domesti hot water storage tank of high-grade steel with PUR Foam insulation (HCFC-free) and Ceraprotet enamel oating with: thermometer adjustable leveling feet built-in aquastat well Magnesium anode The following is paked separately and attahed to the rate: installation fittings pakage: with the neessary hardware temperature and pressure relief valve. Eletrostatially powder-oated sheet metal enlosure panel in a Vitosilver finish. Vitoell 100-V 119 USG (450 L) apaity Domesti hot water storage tank of high-grade steel with wrap-around soft PET insulation (HCFC-free) and Ceraprotet enamel oating with: thermometer adjustable leveling feet built-in aquastat well Magnesium anode The following is paked separately and attahed to the rate: installation fittings pakage: with the neessary hardware temperature and pressure relief valve. Syntheti wrap-around enlosure panel in a Vitosilver finish. 12
13 Vitoell 100-V, CVA/CVAA Series Tehnial Data Standard Equipment (ontinued) Produt Installation Bakflow preventers Where bakflow preventers are required, a domesti water expansion tank installation is reommended in the old water inlet piping before the old water enters the Vitoell. For the bakflow devie, observe loal plumbing odes and regulations. Temperature and pressure relief valve A temperature and pressure relief valve (T&P relief valve) is supplied with the tank. The heating ontrator must install the valve on eah tank in a method meeting ode requirements. If loal odes require a different relief valve, substitute the manufaturer s supplied valve. The tank is approved for 150 psig. Maximum operating pressure is 150 psig. The T&P relief valve supplied with the tank is tested under ANSI Z21.22 Code for Relief Valves and Automati Gas Shut-off Devies for Hot Water Supply Systems. IMPORTANT Sine the heat exhanger oil allows for high MBH input (see Vitoell flow harts), onfirmation that the appropriate and orret size pressure and temperature relief valve is used and installed, is neessary. T&P Valve ASME pressure steam rating CSA temperature steam rating Relief temperature Inlet thread Outlet thread 100 psig 150 psig (where CRN is required) see ratings marked on T&P valve 205 MBH 210 F (99 C) male female Warranty Our warranty for domesti hot water tanks states that the water heated must be of drinking (potable) water quality and that any water treatment equipment in use must funtion orretly. Viessmann aepts no responsibility for damage howsoever aused and reserves the right to withdraw the produt warranty if the produt has been improperly installed or misapplied by the installer, ontrator or final user. In order to qualify for produt warranty, strit adherene to the installation and servie manuals must be assured. In the event that Viessmann nonapproved omponents are utilized, Viessmann reserves the right to withdraw all expressed or implied warranties without written notie. The water to be heated with the Vitoell must be drinking (potable) water quality. If the tank is used to heat other media, the warranty will be null and void. Damage resulting from exessive pressure or temperature is learly not the responsibility of Viessmann. The amount of hloride and sulfate aeptable to the tank is limited. In areas where high onentrations of hloride and sulfate are present in drinking water, please onsult Viessmann for diretions. Sensor Well Vitoell 100-V, 42 to 119 USG (160 to 450 L) apaity The sensor well is welded into the domesti hot water storage tank. 13
14 Sizing Continuous Flow Capaity Chart Vitoell 100-V, CVA/CVAA Series Tehnial Data CVA, 42 and 53 USG (160 and 200 L) apaities Curve A Domesti hot water 40 to 113 F (4 to 45 C) Curve B Domesti hot water 40 to 140 F (4 to 60 C) 14
15 Vitoell 100-V, CVA/CVAA Series Tehnial Data Continuous Flow Capaity Chart (ontinued) Sizing CVAA, 79 USG (300 L) apaity Curve A Domesti hot water 40 to 113 F (4 to 45 C) Curve B Domesti hot water 40 to 140 F (4 to 60 C) 15
16 Sizing Continuous Flow Capaity Chart (ontinued) Vitoell 100-V, CVA/CVAA Series Tehnial Data CVA, 119 USG (450 L) apaity Curve A Domesti hot water 40 to 113 F (4 to 45 C) Curve B Domesti hot water 40 to 140 F (4 to 60 C) 16
17 Vitoell 100-V, CVA/CVAA Series Tehnial Data Continuous Flow Capaity Chart (ontinued) Sizing Example: CVA, 119 USG (450 L) apaity Assume the boiler output to the tank is 170 MBH. Enter hart at left and draw horizontal line aross to reovery rate of 203 GPH or 3.4 GPM for 140 F (60 C) domesti hot water under olumn B. Where the horizontal line intersets the 194 F (90 C) urve is the point of intersetion for the diagonal line used to size the pump. The diagonal line begins at the origin and goes through the point of intersetion extending up to the top of the hart. Read between the referene diagonal lines to get a pump speifiation of 11.9 GPM at 5 ft. To summarize: For a Vitoell-V 100 with 119 USG (450 L) apaity and 170 MBH input, the boiler water temperature is 194 F (90 C), differene between boiler return and supply water temperature is 31 F (17 C), reovery rate is 3.4 GPM of 140 F (60 C) DHW, and the pump required is 11.9 GPM, 5 ft. plus pressure drop in piping and boiler. 17
18 Vitoell 100-V, CVA/CVAA Series Tehnial Data 18
19 Vitoell 100-V, CVA/CVAA Series Tehnial Data 19
20 Vitoell 100-V, CVA/CVAA Series Tehnial Data Tehnial information subjet to hange without notie. Printed on environmentally friendly (reyled and reylable) paper.
Technical Data Manual Model Nos. and pricing: see Price List
VITOCELL-V 00 Indirect-fired domestic hot water storage tank 4 to 0 / 60 to Technical Data Manual Model Nos. and pricing: see Price List Vitocell-V 00 4 to / 60 to Vitocell-V 00 0 / Vitocell-V 00 CVA Series
More informationWATER CLOSET SUPPORTS TECHNICAL DATA
WATER CLOSET SUPPORTS TECHNICAL DATA Smith engineers have developed an unusually omplete line of fixture supports for mounting all types of "off the floor" fixtures. Supports have been designed for water
More informationComputational Analysis of Two Arrangements of a Central Ground-Source Heat Pump System for Residential Buildings
Computational Analysis of Two Arrangements of a Central Ground-Soure Heat Pump System for Residential Buildings Abstrat Ehab Foda, Ala Hasan, Kai Sirén Helsinki University of Tehnology, HVAC Tehnology,
More informationLight Duty Commercial Electric Water Heater
Features Heavy Duty Construction Hydrastone cement lining provides longer tank life Copper-silicon tappings cannot rust or corrode High impact composite jacket eliminates damage during installation and
More informationPRO-CLEAN. Technical Description. Specifications. Space-saving design with minimum heat loss (melamine resin insulation)
PRO-CLEAN Product description Specifications Technical Description Max. backup operating pressure Max. service water operating pressure 3 bar 6 bar Hot water connection " female thread* V4A (no..4) Cold
More informationCommercial Gas Water Heaters
CYCLONE Mxi MODULATING MODULATING BURNER ADVANCES THE CYCLONE TO HIGHER LEVELS OF EFFICIENCY The full line of A. O. Smith Cyclone Mxi condensing water heaters has been designed to provide years of dependable
More informationState of Maryland Participation Agreement for Pre-Tax and Roth Retirement Savings Accounts
State of Maryland Partiipation Agreement for Pre-Tax and Roth Retirement Savings Aounts DC-4531 (08/2015) For help, please all 1-800-966-6355 www.marylandd.om 1 Things to Remember Complete all of the setions
More informationIndirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS
Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS Contents Page Ratings and Specifications..................... 2 Installation Requirements......................
More informationSeries GM. Peerless Boilers. Residential/Commercial Gas Boilers
Peerless Boilers Series GM Residential/Commercial Gas Boilers The Series GM cast iron, hot water boiler is ideal for use in large residences or commercial applications. This gas-fired, atmospheric boiler
More informationBENEFICIARY CHANGE REQUEST
Poliy/Certifiate Number(s) BENEFICIARY CHANGE REQUEST *L2402* *L2402* Setion 1: Insured First Name Middle Name Last Name Permanent Address: City, State, Zip Code Please hek if you would like the address
More informationG234X-55 Conventional Gas Boiler
Engineering Submittal Sheet Boiler Overview C US Engineering Specifications There shall be provided and installed a quantity of Buderus G234X-55 fl oor standing hot water boiler(s), suitable with natural
More informationASME Packaged Indirect Fired Water Heater
Utilizes Or HTHW To Heat Domestic Water, Semi-Instantaneous or Storage Type Model BW Features Reliable Only high grade materials used in construction to ensure long operating life Hydrastone cement lining
More informationHOW TO CALCULATE PRESSURE ANYWHERE IN A PUMP SYSTEM? Jacques Chaurette p. eng. www.lightmypump.com April 2003
HOW TO CALCULATE PRESSURE ANYWHERE IN A PUMP SYSTEM? Jaques Chaurette p. en. www.lihtmypump.om April 003 Synopsis Calulatin the total head of the pump is not the only task of the pump system desiner. Often
More informationTechnical Data Manual
Technical Data Manual Model Nos. and pricing: see Price List Vitodens 100-W WB1B Series Wall-Mounted, gas-fired condensing boiler with optional on demand hot water CombiPLUS Kit Heating input: 37 to 118
More informationINSTALLATION AND SERVICE MANUAL EPJ SERIES INDIRECT WATER HEATERS
INSTALLATION AND SERVICE MANUAL EPJ SERIES INDIRECT WATER HEATERS FOR MODELS EPJ-40 AND EPJ-56 SEE REAR COVER FOR INDEX Read this instruction manual before installation, operation, or service. Failure
More informationECOplus Solar Cylinder
TECHNICAL INFORMATION Solar Cylinder Wagner& Co Connection Options for CONVECTROL II The Effective Convection Brake Technically and fluidically optimized barriers separate the water cooled in the pipes
More informationPerformance Rating of Unitary Air-Conditioning & Air-Source Heat Pump Equipment
ANSI/AHRI Standard 210/240 with Addenda 1 and 2 (formerly ARI Standard 210/240) 2008 Standard for Performane Rating of Unitary Air-Conditioning & Air-Soure Heat Pump Equipment Approved by ANSI in Deember
More informationF220 Series. Installation Instructions. Photoelectric Smoke/Heat Detectors
F0 Series EN Installation Instrutions Photoeletri Smoke/Heat Detetors F0 Series Installation Instrutions.0 General Information EN.0 General Information. F0-B6 Series Bases Use with the F0 Series Heat and
More informationRECON WATER HEATER INSTALLATION FORM
RECON WATER HEATER INSTALLATION FORM Please complete ONE (1) form for each SITE and return to AERCO for warranty validation within 30 days of start-up. After completion, e-mail this form to: STARTUP@AERCO.COM.
More informationElectric Flow Boiler
Electric Flow Boiler EHC offer the most comprehensive range of electric boilers in the market and with our wealth of knowledge and technical expertise we have designed the Slim Jim Electric Flow Boiler
More informationSteam System Best Practices Condensate System Piping
Steam System Best Practices Condensate System Piping Summary The best method for improving steam system energy efficiency, reducing chemical costs, and reducing make-up water costs is to return the maximum
More informationTS150 Visible (exposed) fixing with screws on a timber sub-frame
TS150 Visile (exposed) fixing with srews on a timer su-frame This system offers a ost effetive solution for installing Trespa Meteon panels in a large variety of panel dimensions. Trespa Meteon panels
More informationCommercial Electric Water Heater
MODEL SE Commercial Electric Water Heater 6-120 Gallon Capacity, up to 58 KW in all Three Phase Voltages, Over 6 KW in all Single Phase Voltages Features Heavy Duty Construction Hydrastone cement lining
More informationBetter Boilers. www.ibcboiler.com
Better Boilers FEATURING OUR IBC SUPREME SUPER COIL 316TI STAINLESS STEEL HEAT EXCHANGER. From the factory in Vancouver, our uniquely designed and engineered Super Coil VFC Heat Exchanger is the best Heat
More informationOpenScape 4000 CSTA V7 Connectivity Adapter - CSTA III, Part 2, Version 4.1. Developer s Guide A31003-G9310-I200-1-76D1
OpenSape 4000 CSTA V7 Connetivity Adapter - CSTA III, Part 2, Version 4.1 Developer s Guide A31003-G9310-I200-1-76 Our Quality and Environmental Management Systems are implemented aording to the requirements
More informationMega-Stor INSTALLATION AND OPERATING INSTRUCTIONS ENGINEERING MANUAL MAINTENANCE PARTS
D E S I G N E D T O L E A D Mega-Stor TM Stainless Steel, Indirect Water Heaters INSTALLATION AND OPERATING INSTRUCTIONS ENGINEERING MANUAL MAINTENANCE PARTS CAUTION 1. having a toxicity rating or Class
More informationHEAT EXCHANGERS-2. Associate Professor. IIT Delhi E-mail: prabal@mech.iitd.ac.in. P.Talukdar/ Mech-IITD
HEA EXHANGERS-2 Prabal alukdar Assoiate Professor Department of Mehanial Engineering II Delhi E-mail: prabal@meh.iitd.a.in Multipass and rossflow he subsripts 1 and 2 represent the inlet and outlet, respetively..
More informationInstallation and Operation Instructions Domestic hot water modules: FriwaMidi DN 20 FriwaMaxi DN 25
PAW GmbH & Co. KG Böcklerstr. 11, D-31789 Hameln, Germany Phone: +49-5151-9856-0, Fax: +49-5151-9856-98 E-mail: info@paw.eu, Web: www.paw.eu Installation and Operation Instructions Domestic hot water modules:
More informationCommercial Semi-Instantaneous Water Heaters
FEATURES HWI Models A. O. Smith s HWI models are available for operation with steam or boiler water as the energy source. They are factory assembled with components sized, piped and checked at the factory
More informationTempra / DHC-E. Simply the Best 800.582.8423. The Finest Tankless Electric Water Heater Available! Featuring Advanced Microprocessor Control
ENGINEERING EXCELLENCE Simply the Best The Finest Tankless Electric Water Heater Available! Tempra / DHC-E Featuring Advanced Microprocessor Control Outperforms Bulky Hot Water Tanks Reduces Hot Water
More informationRange Tribune HE Solar Unvented Direct and Indirect Cylinders
Range Tribune HE Solar Unvented Direct and Indirect Cylinders Range Tribune HE Solar cylinders have been designed specifically with Solar applications in mind and are based on the highly successful Range
More informationTHERM Tankless Water Heaters. Applications Manual
THERM Tankless Water Heaters Applications Manual 2 THERM Tankless Water Heater Applications Manual THERM Tankless Water Heater Applications Manual 3 Table of Contents 1 Introduction 4 2 Bosch THERM Model
More informationThermostatic valve Type AVTA
MAKING MODERN LIVING POSSIBLE Data sheet Thermostatic valve Type AVTA Thermostatic valves are used for proportional regulation of flow quantity, depending on the setting and the sensor temperature. The
More informationArt.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS
Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Technical Information sheet 0001/07/Rev01 ENG FUNCTION Series S001 and S002 circulation units are applied to the primary circuit of solar
More informationHL Series - Commercial Heaters Tankless Water Heating Solutions
HL Series - Commercial Heaters 5-18 kw (17,000-61,400 BTUs) Low flow activation options at.15 and.25 GPM (0.6 and 0.9 L-Min) Certified Lead-Free Design Variable Temp Heat Exchanger Pressure Drop Advantage
More informationTHE PERFORMANCE OF TRANSIT TIME FLOWMETERS IN HEATED GAS MIXTURES
Proeedings of FEDSM 98 998 ASME Fluids Engineering Division Summer Meeting June 2-25, 998 Washington DC FEDSM98-529 THE PERFORMANCE OF TRANSIT TIME FLOWMETERS IN HEATED GAS MIXTURES John D. Wright Proess
More informationInstallation & Operation Manual Models: STU150-940
STU-I-O Rev B Installation & Operation Manual Models: STU150-940 IMG00044 LOW LEAD CONTENT WARNING This manual must only be used by a qualified heating installer / service technician. Read all instructions
More informationFindings and Recommendations
Contrating Methods and Administration Findings and Reommendations Finding 9-1 ESD did not utilize a formal written pre-qualifiations proess for seleting experiened design onsultants. ESD hose onsultants
More informationIn order to be able to design beams, we need both moments and shears. 1. Moment a) From direct design method or equivalent frame method
BEAM DESIGN In order to be able to design beams, we need both moments and shears. 1. Moment a) From diret design method or equivalent frame method b) From loads applied diretly to beams inluding beam weight
More informationFLASH TANK ECONOMIZER PRODUCT GUIDE
FLASH TANK ECONOMIZER PRODUCT GUIDE Overview A flash tank is used to recover blowdown energy in the form of flash steam and blowdown. This can only be used with a deaerator or some other pressurized device.
More informationApplications manual. For tankless and point-of-use water heaters
Applications manual For tankless and point-of-use water heaters 2 Bosch applications manual Bosch applications manual 3 Table of Contents 1 Introduction 4 2 Bosch Water Heating Model Certifications 4 3
More informationDIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS
DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS Electronic thermostatically controlled Low power consumption Compact space saving size Short heat-up times Dehumidification of the cabin Quiet when running Combustion
More informationAir Eliminators and Combination Air Eliminators Strainers
Description Air Eliminators and Combination Air Eliminator Strainers are designed to provide separation, elimination and prevention of air in piping systems for a variety of installations and conditions.
More informationInstallation and maintenance instructions
Installation and maintenance instructions Indirect fired domestic hot water tank Logalux ST50/ ST300/ For heating contractors Please read carefully prior to installation and maintenance. 7 747 00 883 09/006
More informationTrin & Stor Model Numbers: S, S-SR, SL Series Version Date: 2014-08-06
Trin & Stor Model Numbers: S, S-SR, SL Series Version Date: 2014-08-06 NEW PRODUCT LINE Stainless Steel Stainless Steel Solar Stone Lined INDIRECT WATER HEATERS INSTALLATION AND OPERATION INSTRUCTIONS
More informationREGULATORS 175/153 Series
175/153 Series 175 HEATING 153 COOLING Watson McDaniel reserves the right to change the designs and/or materials of its products without notice. 2002 Watson McDaniel Company Revised 7/2002 175 / 153 Screwed
More informationModulex. Gas Fired Boiler Systems PIPING GUIDE GF-115-P. Modular, Condensing, Hot Water Boilers Models: 303, 454, 606, 757, 909, 1060. Instruction No.
Instruction No. AERCO INTERNATIONAL, Inc., Northvale, New Jersey, 07647 USA PIPING GUIDE GF-115-P Modulex Gas Fired Boiler Systems Modular, Condensing, Hot Water Boilers Models: 303, 454, 606, 757, 909,
More informationCooking at the Speed of light!
Cooking at the Infrared Cooking & Colouring Infrabaker is a modular infrared continuous cooking system developed by Infrabaker International. The machine is designed to cook and/or put colour on a wide
More informationVITOSOL r 200-T SP2A. VITOSOL 200-T Type SP2A
Technical Data Manual Model Nos. and pricing: see Price List Vacuum tube collector based on the heat pipe principle For the utilisation of solar energy VITOSOL r 200-T SP2A Product may not be exactly as
More informationTherm-Omega-Tech, Inc. Therm-Omega-Tech, Inc. MODEL EMV. A Heavy Duty, Reliable Source For Tepid Water Delivery. Model EMV
MODEL EMV Emergency Safety Shower Water Heater Tepid Water For Emergency Safety Shower/Eyewash Stations Features Heavy Duty Construction Hydrastone cement lining provides tank longevity Copper-silicon
More informationUSER MANUAL INSTALLATION INSTRUCTION WARRANTY REGISTER. Free Hot Water Solar Storage Tank (SST) with Single/Double coil heat exchanger
Installer / Service Provider details USER MANUAL INSTALLATION INSTRUCTION WARRANTY REGISTER Free Hot Water Solar Storage Tank (SST) with Single/Double coil heat exchanger Customer / User Congratulations
More informationThe NEW Greenstar i. intuitive. innovative. improved performance. installation ease
The NEW Greenstar i innovative intuitive improved performance installation ease A NEW look, NEW features and a NEW NAME for the UK s best selling boiler, the Greenstar i Junior 1 Introducing the new Greenstar
More informationElectrician'sMathand BasicElectricalFormulas
Eletriian'sMathand BasiEletrialFormulas MikeHoltEnterprises,In. 1.888.NEC.CODE www.mikeholt.om Introdution Introdution This PDF is a free resoure from Mike Holt Enterprises, In. It s Unit 1 from the Eletrial
More informationAnnual Return/Report of Employee Benefit Plan
Form 5500 Department of the Treasury Internal Revenue Servie Department of Labor Employee Benefits Seurity Administration Pension Benefit Guaranty Corporation Annual Return/Report of Employee Benefit Plan
More informationData Sheet VITOSOL 100. Flat collectors for the utilisation of solar energy. Vitosol 100. Part nos. and prices: see price list
VITOSOL 100 Flat collectors for the utilisation of solar energy Data Sheet Part nos. and prices: see price list File in: Vitotec 1 Manual, Index 16 Vitosol 100 Type s 1.7 Vitosol 100 Type s 2.5 Vitosol
More informationVitodens 200, B2HA / B2HB - Product Introduction
- Product Introduction Foil 2, 10/2015 Viessmann Manufacturing Wall Mounted, Gas-Fired Condensing Boiler Foil 3, 10/2015 Viessmann Manufacturing A member of the Viessmann family of heating products Condensing
More informationModern Gas Heating. The Vitodens 200 gas-fired condensing boiler is prepared for the use of conditioned biogas.
Heating with Gas Modern Gas Heating With fluctuating energy prices and a growing concern for the environment, it pays to modernize your outdated gas-fired boiler. You will save money, and the environment
More informationi e SD No. 2016/0058 HARBOUR DUES (MERCHANT VESSELS) REGULATIONS 2016
i e SD No. 2016/0058 HARBOUR DUES (MERCHANT VESSELS) REGULATIONS 2016 Harbour Dues (Merhant Vessels) Regulations 2016 Index HARBOUR DUES (MERCHANT VESSELS) REGULATIONS 2016 Index Regulation Page 1 Title...
More informationChapter 1 Microeconomics of Consumer Theory
Chapter 1 Miroeonomis of Consumer Theory The two broad ategories of deision-makers in an eonomy are onsumers and firms. Eah individual in eah of these groups makes its deisions in order to ahieve some
More informationMeasurement of Powder Flow Properties that relate to Gravity Flow Behaviour through Industrial Processing Lines
Measurement of Powder Flow Properties that relate to Gravity Flow ehaviour through Industrial Proessing Lines A typial industrial powder proessing line will inlude several storage vessels (e.g. bins, bunkers,
More informationHYDROSTATIC TEST PUMPS
HYDROSTATIC TEST PUMPS MANUAL HYDROSTATIC TEST PUMPS Ideal for testing residential water lines. Also for pressure testing small pressure tanks, sprinkler, boiler and solar systems. Lightweight and easy
More informationSupply chain coordination; A Game Theory approach
aepted for publiation in the journal "Engineering Appliations of Artifiial Intelligene" 2008 upply hain oordination; A Game Theory approah Jean-Claude Hennet x and Yasemin Arda xx x LI CNR-UMR 668 Université
More informationWater Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling
Water Fired Chiller/Chiller-Heater WFC-S Series: 1, 2 and 3 RT Cooling W E A R E F R I E N D L Y T O T H E E A R T H Water Fired SINGLE-EFFECT Chiller or Chiller-Heater Absorption Principle Cooling Cycle
More informationTechnical Data Manual Model Nos. and pricing: see Price List. VITODENS r 222-F
Technical Data Manual Model Nos. and pricing: see Price List For Natural Gas and Liquid Propane Gas Gas-fired floor-mounted condensing DHW combi-boiler 12 to 125 MBH (3.5 to 37 kw) VITODENS r 222-F Product
More informationSTATIONARY WATER HEATERS
OPERATING AND INSTALLATION MANUAL STATIONARY WATER HEATERS OKCE 100 NTR / 2,2 kw OKCE 125 NTR / 2,2 kw OKCE 160 NTR / 2,2 kw OKCE 200 NTR / 2,2 kw OKCE 250 NTR / 2,2 kw OKCE 300 NTR / 2,2 kw OKCE 300 NTR
More informationmodel 1900 FEATURES & BENEFITS SPECIFICATIONS APPLICATIONS OPTIONS Bottle Filler
model Bottle Filler FEATUES & BENEFITS UNIVESAL MOUNTING This unit is perfect as a stand-alone bottle filling station, or easily located over virtually any wall mounted drinking fountain or water cooler
More informationTechnical Data Manual Model Nos. and pricing: see Price List. VITODENS r 222-F
Technical Data Manual Model Nos. and pricing: see Price List For Natural Gas and Liquid Propane Gas Gas-fired floor-mounted condensing DHW combi-boiler 12 to 125 MBH (3.5 to 37 kw) VITODENS r 222-F Product
More informationCustomer Reporting for SaaS Applications. Domain Basics. Managing my Domain
Produtivity Marketpla e Software as a Servie Invoiing Ordering Domains Customer Reporting for SaaS Appliations Domain Basis Managing my Domain Managing Domains Helpful Resoures Managing my Domain If you
More informationNatural geothermal energy.
ROTEX ground source heat pump Natural geothermal energy. ROTEX HPU ground the ground source heat pump that heats with free geothermal energy. Compact, environmentally responsible and uniquely efficient.
More informationResidential/Commercial Gas Condensing High Efficiency Tankless Water Heaters
Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters FEATURES ULTRA-LOW NOx CONDENSING TECHNOLOGY PROVIDES UNPRECEDENTED 0.95 ENERGY FACTOR DURABLE HEAT EXCHANGER Primary Heat Exchanger
More informationIncome Protection CLAIM FORM
Inome Protetion CLAIM FORM PLEASE COMPLETE THIS APPLICATION IN BLACK PEN ONLY USING BLOCK LETTERS 1 PERSONAL DETAILS Poliy numer Important notes: a This form must e ompleted in full and returned to PO
More informationMAKING MODERN LIVING POSSIBLE. Thermostatic valve AVTA. Technical brochure
MAKING MODERN LIVING POSSIBLE Thermostatic valve AVTA Technical brochure 2 IC.PD.500.A3.02-520B3728 Danfoss A/S 07-2009/ RA-MC/mr Contents Page Features............................................................................................4
More informationReplacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS
Replacement parts DO NOT SERVICE THE BOILER WITHOUT A WM97+ MAINTENANCE KIT AVAILABLE Failure to adhere to these guidelines can result in severe personal injury, death or substantial property damage. The
More informationCommercial Gas Water Heaters
UP TO 96% THERMAL EFFICIENCY, DIRECT-VENT FEATURES TM BTH-120 through BTH-500 The A. O. Smith Cyclone Xi family of products represents the industry s most technologically advanced commercial water heaters.
More informationITE. Indirect calorifier ITE - 400/500/600/750/1000. Installation, User and Service Manual. Innovation has a name.
ITE Indirect calorifier ITE - 400/500/600/750/1000 0310 117 Installation, User and Service Manual Innovation has a name. Read this manual carefully Warning Read this manual carefully before starting the
More informationSection 43. Lead Paint Risk Factor NONE WATER HEATER STORAGE ELECTRIC
WATER HEATER STORAGE ELECTRIC Lead Paint Risk Factor NONE TABLE OF CONTENTS PART 1: INSTALLATION REQUIREMENTS FOR CONVENTIONAL HOMES... 1 WATER HEATER REPAIRS... 1 1. APPLIANCE REPAIR... 1 WATER HEATER
More informationCommercial Storage Tanks
Commercial Storage Tanks ALL THE STORAGE CHOICES YOU NEED FOR A TOTAL HOT WATER SUPPLY SYSTEM. INNOVATION AT A GLANCE A. O. SMITH IS THE BEST CHOICE FOR COMPLETE COMMERCIAL WATER HEATING AND STORAGE SYSTEMS
More informationVIESMANN. Datasheet Part numbers and prices: see pricelist VITOSOL 200-F. Flat-plate collector for the utilisation of solar energy
VIESMANN VITOSOL 200-F Flat-plate collector for the utilisation of solar energy Datasheet Part numbers and prices: see pricelist File in: Vitotec folder, register 13 VITOSOL 200-F Type SV2 and SH2 Flat-plate
More informationTABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)
CHRONOMITE INSTANT-FLOW MICRO WATER HEATER INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) TABLE 1 Model No.
More informationSOLAR HEATING SYSTEMS. www.orkli.com
SOLAR HEATING SYSTEMS www.orkli.com // 2 Orkli is one of the main European manufacturers of components for household appliances and innovative solutions for the comfort sector. Its corporate activity is
More informationTechnical Data Manual Model Nos. and pricing: see Price List. VITODENS r 200-W
Technical Data Manual Model Nos. and pricing: see Price List Gas-fired wall-mounted condensing boiler 71 to 530 MBH (21 to 155 kw) Multi-boiler installation 71 to 4240 MBH (21 to 1240 kw) For Natural Gas
More informationDIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS
DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS Electronic thermostatically controlled Low power consumption Compact space saving size Short heat-up times Dehumidification of the cabin Quiet when running Combustion
More informationTechnical Data Manual Model Nos. and pricing: see Price List. VITODENS r 222-F
Technical Data Manual Model Nos. and pricing: see Price List For Natural Gas and Liquid Propane Gas Gas-fired floor-mounted condensing DHW combi-boiler 12 to 125 MBH (3.5 to 37 kw) VITODENS r 222-F Product
More informationCommercial Electric Water Heater
Commercial Electric Water Heater Provides Tepid Water For Emergency Fixtures Features Heavy Duty Construction Hydrastone cement lining provides tank longevity Copper-silicon alloy tappings cannot rust
More informationTrin & Stor Model Numbers: ST Series Version Date: 2012-04-19
Trin & Stor Model Numbers: ST Series Version Date: 2012-04-19 NEW PRODUCT LINE Storage Tanks Stainless Steel Tank TPI Thermostat STORAGE TANK INSTALLATION AND OPERATION INSTRUCTIONS Storage companion to
More informationEquivalents & Conversion Factors 406 Capacity Formulas for Steam Loads 407 Formulas for Control Valve Sizing 408-409
Engineering Data Table of Contents Page No. I II Formulas, Conversions & Guidelines Equivalents & Conversion Factors 406 Capacity Formulas for Steam Loads 407 Formulas for Control Sizing 408-409 Steam
More informationSolar SOLARMAX ELECTRIC BOOSTED SPECIFICATIONS ALL AUSSIE GAS & ELECTRIC BOOSTED SOLAR WATER HEATERS
Solar MAX ELECTRIC BOOSTED SPECIFICATIONS Proudly Australian ALL AUSSIE GAS & ELECTRIC BOOSTED WATER S Harness the power of the Sun. 1 Energy efficiency that s out of this world AquaMAX high efficiency
More information' R ATIONAL. :::~i:. :'.:::::: RETENTION ':: Compliance with the way you work PRODUCT BRIEF
' R :::i:. ATIONAL :'.:::::: RETENTION ':: Compliane with the way you work, PRODUCT BRIEF In-plae Management of Unstrutured Data The explosion of unstrutured data ombined with new laws and regulations
More informationDaikin Altherma hybrid heat pump. The natural combination
Daikin Altherma hybrid heat pump The natural combination Daikin Altherma hybrid heat pump, the natural combination Why choose Daikin Altherma hybrid heat pump? What the customer wants: more energy efficient
More informationIn-Line Air Separators
Air Elimination & Control In-Line Air Separators The AC models of air separators deliver all the quality and performance you expect from Taco products. They are built to last with shell, heads and ANSI
More informationInstallation & Operation Manual Models: SIT030 - SIT119
SIT-I-O Rev K Installation & Operation Manual Models: SIT030 - SIT119 CAUTION: The heat transfer medium must be water or other nontoxic fluid having a toxicity rating or class of 1, as listed in Clinical
More informationINCOME TAX WITHHOLDING GUIDE FOR EMPLOYERS
Virginia Department of Taxation INCOME TAX WITHHOLDING GUIDE FOR EMPLOYERS www.tax.virginia.gov 2614086 Rev. 01/16 Table of Contents Introdution... 1 Important... 1 Where to Get Assistane... 1 Online File
More information) ( )( ) ( ) ( )( ) ( ) ( ) (1)
OPEN CHANNEL FLOW Open hannel flow is haraterized by a surfae in ontat with a gas phase, allowing the fluid to take on shapes and undergo behavior that is impossible in a pipe or other filled onduit. Examples
More informationM SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A
Bulletin 20-20.2 / July 2012 M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A ➀ ➁ ➂ Model Number Key M 2430 C L 1 - A - ➀ Unit Type M=Modular Nominal Capacity 2430=24000 to 30000
More informationAdvanced Heating & Hot Water Systems. Ultra High Efficiency Energy Star Listed Condensing Boiler
Advanced Heating & Hot Water Systems A Trailblazing Energy Star Listed Boiler that Installs like a Mid-Efficiency Boiler with the Performance of a High-Efficiency Product Ultra High Efficiency Energy Star
More informationIntelligent Measurement Processes in 3D Optical Metrology: Producing More Accurate Point Clouds
Intelligent Measurement Proesses in 3D Optial Metrology: Produing More Aurate Point Clouds Charles Mony, Ph.D. 1 President Creaform in. mony@reaform3d.om Daniel Brown, Eng. 1 Produt Manager Creaform in.
More informationLAKE COUNTY ANIMAL SERVICES EXPANSION SECTION 15459
SECTION 15459 PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division-1 Specification sections, apply to work
More informationBUILDING CODE SUMMARY GENERAL NOTES DESIGN BUILD ELECTRICAL DESIGN BUILD MECHANICAL & PLUMBING GENERAL NOTES GENERAL NOTES G101
D D BUILDING CODE SUMMARY GENERAL NOTES PROJECT DESCRIPTION: THIS PROJECT IS THE MINOR RENOVATION OF AN EXISTING OUTPATIENT CLINIC. SCOPE CONSISTS OF PAINT, CARPET, TILE, AND UPGRADE TO DIGITAL X-RAY BUILDING
More informationINCOME TAX WITHHOLDING GUIDE FOR EMPLOYERS
Virginia Department of Taxation INCOME TAX WITHHOLDING GUIDE FOR EMPLOYERS www.tax.virginia.gov 2614086 Rev. 07/14 * Table of Contents Introdution... 1 Important... 1 Where to Get Assistane... 1 Online
More informationINSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL EEMAX ELECTRIC TANKLESS WATER HEATERS IMPORTANT SAFETY INFORMATION
INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL EEMAX ELECTRIC TANKLESS WATER HEATERS IMPORTANT SAFETY INFORMATION When installing or using any high voltage electrical appliance, basic safety precautions
More information