1 45'-0". ll dimensions as noted.. ll wall studs are X4 unless otherwise noted. 3. racing Method: S-WSP (ontinuous Sheathing-Wood Structural Panel) 4. " rigid insulation shall be used as water-resistive barrier per ES-4 Sect ll seams and joints to be taped with 7 8" construction tape. 5. Face of exterior walls to align with face of masonry below. 6. ll window locations to be determined on site unless otherwise dimensioned. 7. ll windows and doors to be covered by porches and flashed. 8. ll windows and doors shall have an overall U-Factor of.35 or less, and a SHG of.30 or less. 9. Water resistant flooring shall be used in kitchen, bathroom(s), and laundry areas ND w/in 3 feet of all exterior doors. 0. lothes dryer shall be exhausted directly to outdoors.. HV eturn is shown for crawl location ONLY. ttic return is above hall ceiling.. Trusses shall be '-0" O.., in-line with framing below, shall bear on exterior walls ONLY (unless otherwise noted), have a raised heel, and " overhangs. 3. Light gray -O- light brown shingles to be used on roof. 4. ny building face within 0' of property line requires protection behind aluminum & vinyl soffits per N 0 Section TEMITE TETMENT: OTE treatment of all framing within 3' of foundation. 6. Insulation shall be installed per manf'rs specs with no substantial gaps, voids, compressions, or wind intrusion. Insulation and air barrier shall be in physical contact with each other. 7. Provide min. of 0' X 0' concrete driveway ND sidewalk to front door. 8. Seal external cracks, joints, etc. around windows and doors with caulking and install pest proof screens. 9. Water heater to be located in designated closet as shown; drain and drain pan shall be installed; drain shall lead directly to outdoors. 0. Drain and drain pan -O- single throw supply valve shall be installed for clothes washer. () x8 SYP POH EMS (TYP) 4X4 TETED POST POPOSED ELETIL PNEL LOTION 3'-0" 0' " * -" 9'- 4 " K DYE 5'-6" EXT X4 WLL H WSH '-4" '-9" F E '-8" H.W. ET. I; SEE NOTE " F 0' " H 9'-6" UPPE INET -7" 5'- 4 " 3'-" '-" 0'-0 " H POPOSED 3" PV TEE 45'-6" 50' 3' -0" 5'-0 4 " 3'-4" '-" VINYL 3'-4" FUT D.W. '-6 4 " LE 0'-5 " -4 " 3'-9" 3'-3" -6" 0'-" 6X6 TETED POST W/ POST SE, TYP () x0 EM E.S. OF POH. '-8"X-4". '-8" X 3'0" Meets all egress and glazing requirements per 0 N ES LDG ode D 36" Exterior Metal Entry Door 3" Exterior Metal Entry Door Windows Exterior Doors 4" Interior Door 3" Interior Door Windows/Doors () E 8" Interior Door F 30" Interior Door G 8" Interior Door H 36" Interior Door I 36" i-hung Interior Door J 48" i-hung Interior Door K 60" i-hung Interior Door () X4 () X4 Per Table 50.5() of the 0 N ES LDG ode Exterior Walls - 4" O.. Interior Walls - 4" O.. * No interior load bearing walls -O- point loads. ll trusses bear on exterior walls. Heated: 865 SF Unheated: 9 SF (covered porches) HITT FO HUMNITY HLOTTE ONTT: IE MSTO cmasto@habitatcharlotte.org FLOO PLN: WLLE IGHT DWG DTE: FE, 04 SHEET TITLE: FLOO PLN PLOT DTE: Mar., 4 0' harlotte

2 IDGE VENT VINYL SHKES NOTE: ULK OUND X6 T OLUMN 3 4 " J-HNNEL LUM. P O S GLE TUSS O S P PLTE LOKS 6 4" 6" O.. 3 /" X6 O S OLUMN P 6X6 POST X6 DED WOOD X0 3/4" " SOFFIT OL P TTHED TO 6X6 POST W/ (4) 3" SEWS 3 8" 6X6 OL. TTHED TO EM THU OL. P W/ () 3" SEWS E.S. OF POST 5 Y. FIEGLSS SINGLE LSS ETINTEED INSTLLED OVE 7 6" OS, 5# FELT (INSTLL PE MNUFTUES WITTEN INSTUTIONS) 8'- " SEE DETIL 3, THIS PGE (TYP) WPPED POH EM & PINTED TPEED OLUMN, UILT IN FIELD 6X6 IK OLUMN: SEE FOUNDTION PLNS FO DETILS 5 FONT ELEVTION MIN FIN. FLOO VINYL SHKES INSTLLED OVE 7 6 " OS, HOUSE WP VINYL LP SIDING W/ TIM (TYP) INSTLLED OVE WLL SHETHING (INSTLL PE MNUFTUES WITTEN INSTUTIONS) 8'- " VINYL PEFOTED EVES NOTE: WOODEN HNDIL/GUD IL S EQUIED, MUST MEET ODE. SEE DETIL THIS PGE 3 OLUMN P DETIL TETED X6 GUDIL W/ X4 P X TETED HNDIL TETED PIKETS 5" O.., TYP 8'- " 8'- " 4X4 TETED POST NH. TO IK STEP W/ " Ø EMED. NHO OLT 4 HNDIL/GUD IL DETIL SIDE ELEVTION 0'. Shall comply with N 0 Edition Section(s) 3 & 3. "Historic " Foundation ONLY: rick foundation on front of house/porch ONLY (See foundation plan for details) HITT FO HUMNITY HLOTTE ONTT: IE MSTO cmasto@habitatcharlotte.org FLOO PLN: WLLE IGHT DWG DTE: FE, 04 SHEET TITLE: ELEVTIONS- of PLOT DTE: Mar., 4 harlotte

3 IDGE VENT 5 Y. FIEGLSS SINGLE LSS ETINTEED INSTLLED OVE 7 6" OS, 5# FELT (INSTLL PE MNUFTUES WITTEN INSTUTIONS) 5 8'- " 8'- " VINYL PEFOTED EVES VINYL LP SIDING W/ TIM (TYP) INSTLLED OVE WLL SHETHING (INSTLL PE MNUFTUES WITTEN INSTUTIONS) MIN FIN. FLOO E ELEVTION 8'- " 8'- " SIDE ELEVTION 0' HITT FO HUMNITY HLOTTE ONTT: IE MSTO cmasto@habitatcharlotte.org FLOO PLN: WLLE IGHT DWG DTE: FE, 04 SHEET TITLE: ELEVTIONS- of PLOT DTE: Mar., 4 harlotte 3

4 50'. Keep foundation walls at least " tall to keep wood members off the ground.. Dig continuous footing under all foundation walls; 8" minimum thickness. 3. ll walls, including porches, must be inside set back lines. 4. No interior load bearing walls or point loads. ll trusses bear on exterior walls. ( OWLOK ON POH EDGES 8" LOK WLL ELOW GDE; 4X8X6 MU & EMENT IK EHIND FE IK 45'-0" -0" ) 5. Top of rowlock on porch to be approx. 4" lower than top of house slab. 6. 4" of 3,000 PSI fiber reinforced concrete, 0 mil. vapor barrier with min. 4" washed stone or equiv recycled concrete over compacted fill, -5 rigid insulation-see Details. 7. Locate within " of each corner, both sides of exterior doors, and every -0" O.. See "ut Sheet" for splice locations. Locate anchors within " each side of splice. 8. Termite Treatment: Structure to be termite treated with OTE when framing is complete. 3'-0" 9'-0" IK STEPS TO GDE, WIDE, OLTS PE SUPEVISO (NOT SHOWN) 0' " 9'- 4 " -" 7'- 4 " /L OF 40" OWLOK FO 36" DOO '-" /L OF 40" OWLOK FO 36" DOO FE IK, TOP OUSE EMENT IK ON TOP OF LOK FOMS LEDGE FO SL 55'-4 6 " FONT POH '-4" 8" -0 " TO /L OFSTEPS 0'-" 3'-9" OWLOK ON POH EDGES IK STEPS TO GDE, WIDE, OLTS PE SUPEVISO (NOT SHOWN) -" 4" LIP FO POH 8" LOK WLL EHIND FE IK " LOK WLL POVIDES 4" LEDGE FO POH EM. IK FE IK 4" LOK 8" LOK HOUSE LENGTH TOP OF SL FE IK EM. IK OMPTED FILL TO SL POH DEPTH POH: " SLOPE OMPTED FILL TO SL FTG. " LOK FTG. FTG. OWLOK FE IK GDE 8" LOK " LOK '-7" 6" SQUE IK OLUMNS E 6 IK OUSES FOM OTTOM OF POH OWLOK. OVE OWLOK=38 " TO TOP OF P=43" ENTE J-OLT, POJET 7" OVE TOP OUSE OF IK 0' HITT FO HUMNITY HLOTTE ONTT: IE MSTO cmasto@habitatcharlotte.org NOT TO SLE; FINL GDE DETEMINES FOUNDTION ND POH HEIGHTS FLOO PLN: WLLE IGHT DWG DTE: FE, 04 harlotte 4 SHEET TITLE: SL-HISTOI PLOT DTE: Mar., 4

5 50'. Keep foundation walls at least " tall to keep wood members off the ground.. Dig continuous footing under all foundation walls; 8" minimum thickness. 3. ll walls, including porches, must be inside set back lines. 4. No interior load bearing walls or point loads. ll trusses bear on exterior walls. ( OWLOK ON POH EDGES 8" LOK WLL ELOW GDE; HOLLOW HEDE LOK, TOP OUSE, TYP 45'-0" -0" ) 5. Top of rowlock on porch to be approx. 4" lower than top of house slab. 6. 4" of 3,000 PSI fiber reinforced concrete, 0 mil. vapor barrier with min. 4" washed stone or equiv recycled concrete over compacted fill, -5 rigid insulation-see Details. 7. Locate within " of each corner, both sides of exterior doors, and a min. of every 3". See "ut Sheet" for splice locations. Locate straps within " each side of splice. Must Meet ode. 8. Front wall ONLY: Face brick w/ ladder type joint reinforcement; " Ø threaded rod anchors, " from corners; -0" O..; 5" min. embedment. 9. Termite Treatment: Structure to be termite treated with OTE when framing is complete. 3'-0" 9'-0" IK STEPS TO GDE, WIDE, OLTS PE SUPEVISO (NOT SHOWN) 0' " 9'- 4 " -" 7'- 4 " /L OF 40" OWLOK FO 36" DOO '-" /L OF 40" OWLOK FO 36" DOO 55'-4 6 " FONT POH '-4" 8" -0 " TO /L OFSTEPS 0'-" 3'-9" OWLOK ON POH EDGES IK STEPS TO GDE, WIDE, OLTS PE SUPEVISO (NOT SHOWN) -" 4" LIP FO POH 8" LOK WLL EHIND FE IK " LOK WLL POVIDES 4" LEDGE FO POH HEDE LOK 8" LOK HOUSE LENGTH TOP OF SL FE IK EM. IK OMPTED FILL TO SL POH DEPTH POH: " SLOPE OMPTED FILL TO SL FTG. " LOK FTG. FTG. OWLOK FE IK GDE 8" LOK " LOK '-7" 6" SQUE IK OLUMNS E 6 IK OUSES FOM OTTOM OF POH OWLOK. OVE OWLOK=38 " TO TOP OF P=43" ENTE J-OLT, POJET 7" OVE TOP OUSE OF IK 0' NOT TO SLE; FINL GDE DETEMINES FOUNDTION ND POH HEIGHTS HITT FO HUMNITY HLOTTE ONTT: IE MSTO cmasto@habitatcharlotte.org FLOO PLN: WLLE IGHT DWG DTE: FE, 04 SHEET TITLE: SL-HISTOI PLOT DTE: Mar., 4 harlotte 5

6 . Dig continuous footing under all foundation walls; 8" minimum thickness, with () #4 rebars, continuous, on -0" O.. max.. ll walls, including porches, must be inside set back lines. 3. See plan for thickened slab/load bearing interior wall locations (if applicable): 0" deep x 8" wide minimum footing with () #4 continuous rebar. 4. Top of rowlock on porch to be approx. 4" lower than top of house slab. 5. 4" of 3,000 PSI fiber reinforced concrete, 0 mil. vapor barrier with min. 4" washed stone or equiv recycled concrete over compacted fill, -5 rigid insulation. 6. Locate within " of each corner, both sides of exterior doors, and a minimum of every 3". See plans for splice locations. Locate straps within " each side of splice. 7. Termite Treatment: Structure to be termite treated with OTE when framing is complete. 9'-0" 0' " 8'-" -0" 7'- 4 " /L OF 40" THESHOLD POJETION FO 36" DOO '-4" 50' 55'-4 6 " 45'-0" '-" /L OF 40" THESHOLD POJETION FO 36" DOO 0'-6" 3'-9" 0'-" 3'-0" '-7" -" 6" SQUE IK OLUMNS OVE POH SL=38 " TO TOP OF P=43" ENTE J-OLT, POJET 7" OVE TOP OUSE OF IK TOP OF SHED SL HOUSE LENGTH TOP OF MONO SL IK/STONE VENEE (OPT) POH DEPTH POH: " SLOPE GDE 6"X6" IK OLUMN 4" TOP OF MONO SL 0" OMPTED FILL TO SL D NOT TO SLE; FINL GDE DETEMINES FOUNDTION ND POH HEIGHTS E E OMPT FILL HITT FO HUMNITY HLOTTE ONTT: IE MSTO cmasto@habitatcharlotte.org FLOO PLN: WLLE IGHT DWG DTE: FE, 04 SHEET TITLE: SL-MONOLITHI PLOT DTE: Mar., 4 0' harlotte 6

7 50'. Maintain minimum floor joist clearance of 8" to grade and minimum dropped girder clearance of " to grade.. Dig continuous footing under all foundation walls; 8" minimum thickness. 3. ll walls, including porches, must be inside set back lines. 4. No interior load bearing walls or point loads. ll trusses bear on exterior walls. ( OWLOK ON POH EDGES 8" LOK WLL (TYP) 45'-0" -0" ). 5. Poured porches-porch floor foundation will be two () brick courses plus a rowlock higher than house foundation. 6. Sill anchors/anchor bolt installation--0" O.. & within " of corners, then doubled every '. 7. Front wall ONLY: Face brick w/ 8" MU filled solid; " Ø rod anchors, " from corners; -0" O..; 5" min. embedment. 8. Foundation vents within 3' of corners. 9. rawl space door-see Site Prep Supervisor for location. 0. Termite Treatment: Structure to be termite treated with OTE when framing is complete ( ). 3'-0" 9'-0" IK STEPS TO GDE, WIDE, OLTS PE SUPEVISO (NOT SHOWN) 0' " 9'- 4 " -" 8" '-4" LUG -0" 9'-7" 0'-3" ' ' 8X6 PIE (TYP), DOPPED ", ON 'X'X8" FTG -0" **NOTE: PIE FOOTINGS N E DUG S SINGLE 0" TENH D -0" 5'-5 " 55'-4 6 " " MU FILLED SOLID, THIS SETION ONLY FONT POH -0 " TO /L OFSTEPS 0'-" 3'-9" OWLOK ON POH EDGES IK STEPS TO GDE, WIDE, OLTS PE SUPEVISO (NOT SHOWN) WTE POOFING GVEL 8" PIE FILLED SOLID 'X' NOT TO SLE FTG. 8" LOK HOUSE LENGTH ENTE EM EM. IK 4" SOLID LOK POH DEPTH POH: " SLOPE OMPTED FILL TO SL JUMO IK " LOK FTG. FTG. FTG. OWLOK FE IK GDE 8" LOK " LOK FTG. 8" LOK PIE FILLED SOLID -" 4" LIP FO POH '-7" 8" LOK WLL EHIND FE IK " LOK WLL POVIDES 4" LEDGE FO POH 6" SQUE IK OLUMNS E 6 IK OUSES FOM OTTOM OF POH OWLOK. OVE OWLOK=38 " TO TOP OF P=43" ENTE J-OLT, POJET 7" OVE TOP OUSE OF IK 0' NOT TO SLE; FINL GDE DETEMINES FOUNDTION ND POH HEIGHTS D HITT FO HUMNITY HLOTTE ONTT: IE MSTO cmasto@habitatcharlotte.org FLOO PLN: WLLE IGHT DWG DTE: FE, 04 SHEET TITLE: WL-HISTOI PLOT DTE: Mar., 4 harlotte 7

8 . Long walls that run parallel with joists need a joist or blocking underneath. Place X0 3'-0" O..; consider plumbing when running extra joists. Dimensions are to outside face or block & center of joist unless otherwise noted 3. Use pressure treated lumber adjacent to all foundation brick and block material ENTELINES SHOWN OUTSIDE FE OF ND; "Historic " X0 floor joists--top edges flush with girders & band joists; ; double X girders; X0 band joists DYE WSH H.W. 3' DOULE X0 HEDES '-8" LE DOULE DOULE 3' O.. 8'-4" 9'-7" 0' " '-4" -3" 9'-7" 0'-" " EXT JOIST " EXT JOIST 0' HITT FO HUMNITY HLOTTE ONTT: IE MSTO cmasto@habitatcharlotte.org FLOO PLN: WLLE IGHT DWG DTE: FE, 04 SHEET TITLE: JOIST PLOT DTE: Mar., 4 harlotte 8

9 (Measurements are left to right & back to front, looking at the house). -0">'-0">5'-9" L. 8'-0">'-0">-" L. '-6". 0'-0 3 4". 8'-9 3 4" F. 9'-5" P. 3'-5 " P. - " HL. 5'-7 ">'-7" H. - " (x4)>3'-0" short (x6)-corner in ". 5'-5 3 4" 3. 5'-5 3 4" - x6 4. '-8" 5. 3'-0 " 6. 5'-6" 7. 0'-0 3 4" 8. 0'-0 3 4" 9. '-" 0. '-" K DYE 6 WSH 5 HL 0 H.W. 4 3 H P F P L FIELD UILT LDDE. See additional framing documents for pre-fabricated component building & other framing information. Use "Wall Plate ut List" (above) when preparing house for framing 3. ll stud spacing shall be '-0" O.. unless otherwise noted. Exterior stud spacing shall be in line with truss layout above L D E F Window omponet Window omponet 36" Door omponet 3" Door omponet 4" Ladder Stud orner X4 studs: X4 studs: G Int. Hollow orner H Partition Tie I Partition Tie J Partition Tie K Historic eam Pocket L Standard eam Pocket X4 stud count in pre-fab. components: X6 stud count in pre-fab. components: X4 studs: X6 studs: TOTL X4 studs ordered: TOTL X6 studs ordered: HITT FO HUMNITY HLOTTE ONTT: IE MSTO cmasto@habitatcharlotte.org FLOO PLN: WLLE IGHT DWG DTE: FE, 04 SHEET TITLE: FMING PLN PLOT DTE: Mar., 4 0' harlotte S-

10 . ll dimensions as noted.. ll wall studs are X4 unless otherwise noted. 3. racing Method: S-WSP (ontinuous Sheathing-Wood Structural Panel) 4. " rigid insulation shall be used as water-resistive barrier per ES-4 Sect ll seams and joints to be taped with 7 8" construction tape. 5. Face of exterior walls to align with face of masonry below. 6. ll window locations to be determined on site unless otherwise dimensioned. 7. ll windows and doors to be covered by porches and flashed. 8. ll windows and doors shall have an overall U-Factor of.35 or less, and a SHG of.30 or less. 9. Water resistant flooring shall be used in kitchen, bathroom(s), and laundry areas ND w/in 3 feet of all exterior doors. 0. lothes dryer shall be exhausted directly to outdoors.. HV eturn is shown for crawl location ONLY. ttic return is above hall ceiling.. Trusses shall be '-0" O.., in-line with framing below, shall bear on exterior walls ONLY (unless otherwise noted), have a raised heel, and " overhangs. 3. Light gray -O- light brown shingles to be used on roof. 4. ny building face within 0' of property line requires protection behind aluminum & vinyl soffits per N 0 Section TEMITE TETMENT: OTE treatment of all framing within 3' of foundation. 6. Insulation shall be installed per manf'rs specs with no substantial gaps, voids, compressions, or wind intrusion. Insulation and air barrier shall be in physical contact with each other. 7. Provide min. of 0' X 0' concrete driveway ND sidewalk to front door. POPOSED ELETIL PNEL LOTION 3'-0" 0' " 4X4 TETED POST * -" 9'- 4 " 3'-" '-" 0'-0 " K H EXT X4 WLL 5'-6" '-4" F " E ET. I; SEE NOTE '-9" F '-8" 0' " H H 45'-6" POPOSED 3" PV TEE 5'- 4 " 50' 3' 5'-0 4 " 3'-4" -7" UPPE INET 9'-6" '-" VINYL 3'-4" '-6 4 " LE FUT D.W. 0'-5 " 3'-9" () x0 EM E.S. OF POH 6X6 TETED POST W/ POST SE, TYP -6" 3'-3" -4 " 0'-" 8. Seal external cracks, joints, etc. around windows and doors with caulking and install pest proof screens. 9. Water heater to be located in designated closet as shown; drain and drain pan shall be installed; drain shall lead directly to outdoors. 0. Drain and drain pan -O- single throw supply valve shall be installed for clothes washer. () x8 SYP POH EMS (TYP) 45'-0" -0". '-8"X-4". '-8" X 3'0" Meets all egress and glazing requirements per 0 N ES LDG ode D 36" Exterior Metal Entry Door 3" Exterior Metal Entry Door Windows Exterior Doors 4" Interior Door 3" Interior Door Windows/Doors () E 8" Interior Door F 30" Interior Door G 8" Interior Door H 36" Interior Door I 36" i-hung Interior Door J 48" i-hung Interior Door K 60" i-hung Interior Door () X4 () X4 Per Table 50.5() of the 0 N ES LDG ode Exterior Walls - 4" O.. Interior Walls - 4" O.. * No interior load bearing walls -O- point loads. ll trusses bear on exterior walls. Heated: 865 SF Unheated: 9 SF (covered porches) HITT FO HUMNITY HLOTTE ONTT: IE MSTO cmasto@habitatcharlotte.org FLOO PLN: WLLE LEFT DWG DTE: FE, 04 harlotte 9 SHEET TITLE: FLOO PLN PLOT DTE: Mar., 4 0'

11 IDGE VENT VINYL SHKES NOTE: ULK OUND X6 T OLUMN 3 4 " J-HNNEL LUM. P O S GLE TUSS O S P PLTE LOKS 6 4" 6" O.. 3 /" X6 O S OLUMN P 6X6 POST X6 DED WOOD X0 3/4" " SOFFIT OL P TTHED TO 6X6 POST W/ (4) 3" SEWS 3 8" 6X6 OL. TTHED TO EM THU OL. P W/ () 3" SEWS E.S. OF POST VINYL SHKES INSTLLED OVE 7 6" OS, HOUSE WP VINYL LP SIDING W/ TIM (TYP) INSTLLED OVE WLL SHETHING (INSTLL PE MNUFTUES WITTEN INSTUTIONS) 8'- " VINYL PEFOTED EVES MIN FIN. FLOO NOTE: WOODEN HNDIL/GUD IL S EQUIED, MUST MEET ODE. SEE DETIL THIS PGE FONT ELEVTION 5 5 Y. FIEGLSS SINGLE LSS ETINTEED INSTLLED OVE 7 6" OS, 5# FELT (INSTLL PE MNUFTUES WITTEN INSTUTIONS) 8'- " SEE DETIL 3, THIS PGE (TYP) WPPED POH EM & PINTED TPEED OLUMN, UILT IN FIELD 6X6 IK OLUMN: SEE FOUNDTION PLNS FO DETILS 3 OLUMN P DETIL TETED X6 GUDIL W/ X4 P X TETED HNDIL TETED PIKETS 5" O.., TYP 8'- " 8'- " 4X4 TETED POST NH. TO IK STEP W/ " Ø EMED. NHO OLT 4 HNDIL/GUD IL DETIL SIDE ELEVTION 0'. Shall comply with N 0 Edition Section(s) 3 & 3. "Historic " Foundation ONLY: rick foundation on front of house/porch ONLY (See foundation plan for details) HITT FO HUMNITY HLOTTE ONTT: IE MSTO cmasto@habitatcharlotte.org FLOO PLN: WLLE LEFT DWG DTE: FE, 04 SHEET TITLE: ELEVTIONS- of PLOT DTE: Mar., 4 harlotte 0

12 IDGE VENT 5 Y. FIEGLSS SINGLE LSS ETINTEED INSTLLED OVE 7 6 " OS, 5# FELT (INSTLL PE MNUFTUES WITTEN INSTUTIONS) 5 8'- " 8'- " VINYL LP SIDING W/ TIM (TYP) INSTLLED OVE WLL SHETHING (INSTLL PE MNUFTUES WITTEN INSTUTIONS) VINYL PEFOTED EVES MIN FIN. FLOO E ELEVTION 8'- " 8'- " SIDE ELEVTION 0' HITT FO HUMNITY HLOTTE ONTT: IE MSTO cmasto@habitatcharlotte.org FLOO PLN: WLLE LEFT DWG DTE: FE, 04 SHEET TITLE: ELEVTIONS- of PLOT DTE: Mar., 4 harlotte

13 . Keep foundation walls at least " tall to keep wood members off the ground.. Dig continuous footing under all foundation walls; 8" minimum thickness. 3. ll walls, including porches, must be inside set back lines. 4. No interior load bearing walls or point loads. ll trusses bear on exterior walls. ( '-7" 6" SQUE IK OLUMNS E 6 IK OUSES FOM OTTOM OF POH OWLOK. OVE OWLOK=38 " TO TOP OF P=43" ENTE J-OLT, POJET 7" OVE TOP OUSE OF IK " LOK WLL POVIDES 4" LEDGE FO POH ) 5. Top of rowlock on porch to be approx. 4" lower than top of house slab. 6. 4" of 3,000 PSI fiber reinforced concrete, 0 mil. vapor barrier with min. 4" washed stone or equiv recycled concrete over compacted fill, -5 rigid insulation-see Details. 7. Locate within " of each corner, both sides of exterior doors, and every -0" O.. See "ut Sheet" for splice locations. Locate anchors within " each side of splice. 8. Termite Treatment: Structure to be termite treated with OTE when framing is complete. 3'-0" 9'-0" 0' " -" 4" LIP FO POH EMENT IK ON TOP OF LOK FOMS LEDGE FO SL FE IK, TOP OUSE FONT POH -0 " TO /L OFSTEPS 3'-9" 8" LOK WLL EHIND FE IK IK STEPS TO GDE, WIDE, OLTS PE SUPEVISO (NOT SHOWN) OWLOK ON POH EDGES IK STEPS TO GDE, WIDE, OLTS PE SUPEVISO (NOT SHOWN) -" 9'- 4 " 7'- 4 " /L OF 40" OWLOK FO 36" DOO '-" /L OF 40" OWLOK FO 36" DOO 55'-4 6 " '-4" 8" 0'-" OWLOK ON POH EDGES 8" LOK WLL ELOW GDE; 4X8X6 MU & EMENT IK EHIND FE IK -0" 45'-0" 50' EM. IK FE IK 4" LOK 8" LOK HOUSE LENGTH TOP OF SL FE IK EM. IK OMPTED FILL TO SL POH DEPTH POH: " SLOPE OMPTED FILL TO SL FTG. " LOK FTG. FTG. OWLOK FE IK GDE 8" LOK " LOK 0' HITT FO HUMNITY HLOTTE ONTT: IE MSTO cmasto@habitatcharlotte.org NOT TO SLE; FINL GDE DETEMINES FOUNDTION ND POH HEIGHTS FLOO PLN: WLLE LEFT DWG DTE: FE, 04 harlotte SHEET TITLE: SL-HISTOI PLOT DTE: Mar., 4

14 . Keep foundation walls at least " tall to keep wood members off the ground.. Dig continuous footing under all foundation walls; 8" minimum thickness. 3. ll walls, including porches, must be inside set back lines. 4. No interior load bearing walls or point loads. ll trusses bear on exterior walls. ( '-7" 6" SQUE IK OLUMNS E 6 IK OUSES FOM OTTOM OF POH OWLOK. OVE OWLOK=38 " TO TOP OF P=43" ENTE J-OLT, POJET 7" OVE TOP OUSE OF IK " LOK WLL POVIDES 4" LEDGE FO POH ) 5. Top of rowlock on porch to be approx. 4" lower than top of house slab. 6. 4" of 3,000 PSI fiber reinforced concrete, 0 mil. vapor barrier with min. 4" washed stone or equiv recycled concrete over compacted fill, -5 rigid insulation-see Details. 7. Locate within " of each corner, both sides of exterior doors, and a min. of every 3". See "ut Sheet" for splice locations. Locate straps within " each side of splice. Must Meet ode. 8. Front wall ONLY: Face brick w/ ladder type joint reinforcement; " Ø threaded rod anchors, " from corners; -0" O..; 5" min. embedment. 9. Termite Treatment: Structure to be termite treated with OTE when framing is complete. 3'-0" 9'-0" 0' " IK STEPS TO GDE, WIDE, OLTS PE SUPEVISO (NOT SHOWN) -" 9'- 4 " -" 7'- 4 " /L OF 40" OWLOK FO 36" DOO 4" LIP FO POH '-" /L OF 40" OWLOK FO 36" DOO 55'-4 6 " FONT POH -0 " TO /L OFSTEPS '-4" 8" 3'-9" 0'-" 8" LOK WLL EHIND FE IK IK STEPS TO GDE, WIDE, OLTS PE SUPEVISO (NOT SHOWN) OWLOK ON POH EDGES OWLOK ON POH EDGES 8" LOK WLL ELOW GDE; HOLLOW HEDE LOK, TOP OUSE, TYP -0" 45'-0" 50' HEDE LOK 8" LOK HOUSE LENGTH TOP OF SL FE IK EM. IK OMPTED FILL TO SL POH DEPTH POH: " SLOPE OMPTED FILL TO SL FTG. " LOK FTG. FTG. OWLOK FE IK GDE 8" LOK " LOK 0' NOT TO SLE; FINL GDE DETEMINES FOUNDTION ND POH HEIGHTS HITT FO HUMNITY HLOTTE ONTT: IE MSTO cmasto@habitatcharlotte.org FLOO PLN: WLLE LEFT DWG DTE: FE, 04 SHEET TITLE: SL-HISTOI PLOT DTE: Mar., 4 harlotte 3

15 . Dig continuous footing under all foundation walls; 8" minimum thickness, with () #4 rebars, continuous, on -0" O.. max.. ll walls, including porches, must be inside set back lines. 3. See plan for thickened slab/load bearing interior wall locations (if applicable): 0" deep x 8" wide minimum footing with () #4 continuous rebar. 4. Top of rowlock on porch to be approx. 4" lower than top of house slab. 5. 4" of 3,000 PSI fiber reinforced concrete, 0 mil. vapor barrier with min. 4" washed stone or equiv recycled concrete over compacted fill, -5 rigid insulation. 6. Locate within " of each corner, both sides of exterior doors, and a minimum of every 3". See plans for splice locations. Locate straps within " each side of splice. 7. Termite Treatment: Structure to be termite treated with OTE when framing is complete. 9'-0" 0' " 7'- 4 " /L OF 40" THESHOLD POJETION FO 36" DOO -" 55'-4 6 " '-7" '-" /L OF 40" THESHOLD POJETION FO 36" DOO 0'-6" 3'-9" 6" SQUE IK OLUMNS OVE POH SL=38 " TO TOP OF P=43" ENTE J-OLT, POJET 7" OVE TOP OUSE OF IK 3'-0" 8'-" '-4" 0'-" -0" 45'-0" 50' TOP OF SHED SL HOUSE LENGTH TOP OF MONO SL IK/STONE VENEE (OPT) POH DEPTH POH: " SLOPE GDE 6"X6" IK OLUMN 4" TOP OF MONO SL 0" OMPTED FILL TO SL D NOT TO SLE; FINL GDE DETEMINES FOUNDTION ND POH HEIGHTS E E OMPT FILL HITT FO HUMNITY HLOTTE ONTT: IE MSTO cmasto@habitatcharlotte.org FLOO PLN: WLLE LEFT DWG DTE: FE, 04 SHEET TITLE: SL-MONOLITHI PLOT DTE: Mar., 4 0' harlotte 4

16 . Maintain minimum floor joist clearance of 8" to grade and minimum dropped girder clearance of " to grade.. Dig continuous footing under all foundation walls; 8" minimum thickness. 3. ll walls, including porches, must be inside set back lines. 4. No interior load bearing walls or point loads. ll trusses bear on exterior walls. ( ). 5. Poured porches-porch floor foundation will be two () brick courses plus a rowlock higher than house foundation. 6. Sill anchors/anchor bolt installation--0" O.. & within " of corners, then doubled every '. 7. Front wall ONLY: Face brick w/ 8" MU filled solid; " Ø rod anchors, " from corners; -0" O..; 5" min. embedment. 8. Foundation vents within 3' of corners. 9. rawl space door-see Site Prep Supervisor for location. 0. Termite Treatment: Structure to be termite treated with OTE when framing is complete ( ). 3'-0" 9'-0" 0' " IK STEPS TO GDE, WIDE, OLTS PE SUPEVISO (NOT SHOWN) '-4" 8" -" 9'- 4 " LUG -" 0'-3" **NOTE: PIE FOOTINGS N E DUG S SINGLE 0" TENH -0" 9'-7" ' ' D -0" 8X6 PIE (TYP), DOPPED ", ON 'X'X8" FTG '-7" 4" LIP FO POH -0" 5'-5 " 55'-4 6 " FONT POH " MU FILLED SOLID, THIS SETION ONLY -0 " TO /L OFSTEPS 6" SQUE IK OLUMNS E 6 IK OUSES FOM OTTOM OF POH OWLOK. OVE OWLOK=38 " TO TOP OF P=43" ENTE J-OLT, POJET 7" OVE TOP OUSE OF IK 3'-9" 0'-" " LOK WLL POVIDES 4" LEDGE FO POH 8" LOK WLL EHIND FE IK IK STEPS TO GDE, WIDE, OLTS PE SUPEVISO (NOT SHOWN) OWLOK ON POH EDGES WTE POOFING 8" LOK GVEL 'X' FTG. OWLOK ON POH EDGES 8" LOK WLL (TYP) -0" NOT TO SLE 50' 45'-0" 8" PIE FILLED SOLID HOUSE LENGTH ENTE EM EM. IK 4" SOLID LOK POH DEPTH POH: " SLOPE OMPTED FILL TO SL JUMO IK " LOK FTG. FTG. FTG. OWLOK FE IK GDE 8" LOK " LOK FTG. 8" LOK PIE FILLED SOLID 0' NOT TO SLE; FINL GDE DETEMINES FOUNDTION ND POH HEIGHTS D HITT FO HUMNITY HLOTTE ONTT: IE MSTO cmasto@habitatcharlotte.org FLOO PLN: WLLE LEFT DWG DTE: FE, 04 SHEET TITLE: WL-HISTOI PLOT DTE: Mar., 4 harlotte 5

17 . Long walls that run parallel with joists need a joist or blocking underneath. Place X0 3'-0" O..; consider plumbing when running extra joists. Dimensions are to outside face or block & center of joist unless otherwise noted 3. Use pressure treated lumber adjacent to all foundation brick and block material " EXT JOIST " EXT JOIST "Historic " X0 floor joists--top edges flush with girders & band joists; ; double X girders; X0 band joists 0' " 8'-4" DOULE DOULE '-4" -3" DOULE X0 HEDES 3' 9'-7" 3' O.. 9'-7" 0'-" '-8" LE ENTELINES SHOWN OUTSIDE FE OF ND; 0' HITT FO HUMNITY HLOTTE ONTT: IE MSTO cmasto@habitatcharlotte.org FLOO PLN: WLLE LEFT DWG DTE: FE, 04 SHEET TITLE: JOIST PLOT DTE: Mar., 4 harlotte 6

18 (Measurements are left to right & back to front, looking at the house) L. -0">'-0">5'-9". 8'-0">'-0">-". '-6". 0'-0 3 4". 8'-9 3 4" F. 9'-5" P. 3'-5 " P. - ". 5'-7 ">'-7" H. - " (x4)>3'-0" short (x6)-corner in FIELD UILT LDDE L L ". 5'-5 3 4" 3. 5'-5 3 4" - x6 4. '-8" 5. 3'-0 " 6. 5'-6" 7. 0'-0 3 4" 8. 0'-0 3 4" 9. '-" 0. '-" P P H HL K 4 F See additional framing documents for pre-fabricated component building & other framing information. Use "Wall Plate ut List" (above) when preparing house for framing 3. ll stud spacing shall be '-0" O.. unless otherwise noted. Exterior stud spacing shall be in line with truss layout above D E F Window omponet Window omponet 36" Door omponet 3" Door omponet 4" Ladder Stud orner X4 studs: X4 studs: G Int. Hollow orner H Partition Tie I Partition Tie J Partition Tie K Historic eam Pocket L Standard eam Pocket X4 stud count in pre-fab. components: X6 stud count in pre-fab. components: X4 studs: X6 studs: TOTL X4 studs ordered: TOTL X6 studs ordered: HITT FO HUMNITY HLOTTE ONTT: IE MSTO cmasto@habitatcharlotte.org FLOO PLN: WLLE LEFT DWG DTE: FE, 04 SHEET TITLE: FMING PLN PLOT DTE: Mar., 4 0' harlotte S-

(2) 2x8 SYP PORCH BEAMS (TYP) 4X4 TREATED POST 24' 5'-8" 3'-3 7 8 " 3'-37 8 " 5'-0 1 4 " 5'-11 1 2 " DRYER WASH RET. AIR; SEE NOTE 11 4'-10 1 4 "

(2) 2x8 SYP PORCH BEAMS (TYP) 4X4 TREATED POST 24' 5'-8 3'-3 7 8  3'-37 8  5'-0 1 4  5'-11 1 2  DRYER WASH RET. AIR; SEE NOTE 11 4'-10 1 4 . ll dimensions as noted.. ll wall studs are X4 unless otherwise noted.. racing Method: S-WSP (ontinuous Sheathing-Wood Structural Panel) 4. " rigid insulation shall be used as water-resistive barrier

More information

Custom 30 x 20-8 Garage Plan Plan #g233 By SDS-CAD Specialized Design Systems

Custom 30 x 20-8 Garage Plan Plan #g233 By SDS-CAD Specialized Design Systems P O Box 34 Mendon, Utah Custom 30 x 20-8 Garage Plan Plan #g233 By Page 1 Title Page Page 2 Main Floor Plan Page 3 Foundation Plan Page 4 Elevation Views Page 5 Framing and Details Page 6 Typical Section

More information

Additions and Alterations

Additions and Alterations Additions and Alterations Addition and alteration construction is a miscellaneous grouping of home improvement and renovation projects that are generally geared toward the enhancement of an existing principal

More information

Fig. 2 WALL-TO-WALL PANEL CONNECTIONS CORNER WALL CONNECTION

Fig. 2 WALL-TO-WALL PANEL CONNECTIONS CORNER WALL CONNECTION SIPS SCREWS WITH MINIMUM 1" PENETRATION IN WOOD MEMBER IN SIP WALL PANEL CONNECTED TO @ 24" O.C. MAXIMUM OUTSIDE SKIN EACH SIDE OF FRAMING TYP. AS RECOMMENDED BY FOAM CORE AS EACH SIDE OF FRAMING TYP.

More information

Superform Products Ltd.

Superform Products Ltd. TYPICAL CORNER REINFORCING NOTE : SEE ENGINEERED REBAR SCHEDULES SUPPLIED BY THE MANUFACTURER STEEL REINFORCEMENT WALL CORNER 90 Copyright 2012 Sept. 2012 5.1.1 Rebar Spacing 6" 12" Max. Load LB./FT. 2000

More information

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003) NCMA TEK National Concrete Masonry Association an information series from the national authority on concrete masonry technology CONCRETE MASONRY FOUNDATION WALL DETAILS TEK 5-3A Details (2003) Keywords:

More information

4. ANCHOR BOLTS AND STRAPS a. ½" anchor bolts shall be embedded 7" into concrete a maximum of 6' on center and 12" from corners and ends of plates.

4. ANCHOR BOLTS AND STRAPS a. ½ anchor bolts shall be embedded 7 into concrete a maximum of 6' on center and 12 from corners and ends of plates. GENERAL CODE REQUIREMENTS (BASEMENTS) 1. FOOTINGS a. Footings shall be below frost line depth (42"). b. For an 8" foundation wall, footings shall be no less than 8" deep and 16" wide. c. Steel reinforcement

More information

PDmB, Inc. Definitions

PDmB, Inc. Definitions Page 1 of 11 Definitions S Satisfactory Meets industry standards for proper material and installation NP Not Present Condition or item was not present at time of inspection NI Not Inspected Condition or

More information

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances. Basement Finishing Guide Community Development Department Building Inspections Division 5200 85 th Avenue North / Brooklyn Park, MN 55443 Phone: (763) 488-6379 / Fax: (763) 493-8171 6/15 www.brooklynpark.org

More information

Residential Foundations and Basements

Residential Foundations and Basements Residential Foundations and Basements Disclaimer All of the following information is based on the 2006 International Residential Code with Kentucky Amendments. As some information is paraphrased, article

More information

1/2" CDX PLY W/ 8d @ 6"/ 6"/ 12" 2x ROOF RAFTERS @ 16"OC W/ R-30 BATT. INSUL. (COMMON NAILS)

1/2 CDX PLY W/ 8d @ 6/ 6/ 12 2x ROOF RAFTERS @ 16OC W/ R-30 BATT. INSUL. (COMMON NAILS) TYPE V CONSTRUCTION IS A CLASSIFICATION OF BUILDINGS BY CONSTRUCTION MATERIALS AND METHODS. IT IS THE LEAST RESTRICTIVE PERMITTED BY THE UNIFORM BUILDING CODE AND INCLUDES LIGHT, WOOD-FRAME CONSTRUCTION.

More information

Pre-Drywall Inspection Report

Pre-Drywall Inspection Report SM MEDALLION INSPECTIONS helping people make informed decisions Pre-Drywall Inspection Report 5657 Garden Valley Place Milton, Georgia 30024 Prepared for Betsy and Paul Dougherty January12, 2015 Medallion

More information

Basic Requirements for Residential Plan Review _

Basic Requirements for Residential Plan Review _ Basic Requirements for Residential Plan Review _ Below you will find the basic requirements for your plan submittal. General: Drawn to scale Plan Size minimum: 9 x 12 Designer, Engineer, or Architect name,

More information

March 14, 2007. Installation of Bay, Bow and Garden Windows

March 14, 2007. Installation of Bay, Bow and Garden Windows March 14, 2007 Re: Installation of Bay, Bow and Garden Windows Attached are the Atrium Companies, Inc recommendation for the installation of bay, bow and garden windows. These instructions were developed

More information

Mark Cramer Inspection Services, Inc.

Mark Cramer Inspection Services, Inc. Mark Cramer Inspection Services, Inc. 492 Twentieth Avenue, Indian Rocks Beach, FL 34635-2970 (727) 595-4211 Fax (727) 596-7583 Certified Member #12085 American Society of Home Inspectors Construction

More information

POST AND FRAME STRUCTURES (Pole Barns)

POST AND FRAME STRUCTURES (Pole Barns) POST AND FRAME STRUCTURES (Pole Barns) Post and frame structures. The following requirements serve as minimum standards for post and frame structures within all of the following structural limitations:

More information

Engineered Wood Foundations

Engineered Wood Foundations Engineered Wood Foundations Emeraldfoundations.com 1 EWF Planning and Installation manual This manual will serve as a guide to planning and installing an Emerald Foundation system. This system is comprised

More information

HfHMD uses LP SmartSide siding and trim.

HfHMD uses LP SmartSide siding and trim. HfHMD uses LP SmartSide siding and trim. These products are: More durable than cement fiber board. Much more volunteer-friendly to install. When installed correctly, have a 5/50- year pro-rated warranty.

More information

Uniform Construction Code (UCC) Building Permit Application Package

Uniform Construction Code (UCC) Building Permit Application Package Uniform Construction Code (UCC) Residential Building Permit Application Package Per the Uniform Construction Code (UCC) all structures must be built per the standards of the most currently adopted International

More information

Residential Building Inspection Policies

Residential Building Inspection Policies CONCRETE 1. A footing inspection has been called in, but a monolithic slab shows on the plans. Cancel the footing and create a slab inspection, as long as there is a Passed Plumbing Rough (05). 2. A stemwall

More information

STANDARD OPEN PATIO COVER

STANDARD OPEN PATIO COVER STANDARD OPEN PATIO COVER BUILDING & SAFETY DIVISION 201 E. LA HABRA BLVD. LA HABRA, CA 90631 62-90-9710 Call Before You Dig 1-800-227-2600 PLEASE NOTE: This information Bulletin is made available to assist

More information

Estimating Database Checklist

Estimating Database Checklist Estimating Database Checklist If you are creating a new estimating database for projects, the following list offers a thorough listing of Main and Sub Categories. You can also use it as a checklist to

More information

Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit

Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit R-H-DI1 INSULATION BATT NR-E-IB1 Avoid Using Batt Insulation With Metal Framing Batt insulation should not be used with metal framing systems. Although it is common to see fiberglass batt insulation installed

More information

HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES

HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES 101 Retrofits Required. Pursuant to Section 553.844 553.884, Florida Statutes, strengthening of existing site-built,

More information

Residential Inspection Guidelines

Residential Inspection Guidelines Residential Inspection Guidelines 201 Pre-Pour Foundation Dimensions Building Location Certificate - if required in the building consent Construction and Advice Notes Check the building dimensions against

More information

RESIDENTIAL MASONRY A BEST PRACTICES GUIDE

RESIDENTIAL MASONRY A BEST PRACTICES GUIDE RESIDENTIAL MASONRY A BEST PRACTICES GUIDE Build With Brick Build With Boral CONTENTS BRICK :01 MASONRY CEMENT :03 MASONRY SAND :04 WALL TIES :05 STEEL LINTELS :07 DRAINAGE WALL SYSTEM :09 FLASHING :11

More information

Chapter 3 Pre-Installation, Foundations and Piers

Chapter 3 Pre-Installation, Foundations and Piers Chapter 3 Pre-Installation, Foundations and Piers 3-1 Pre-Installation Establishes the minimum requirements for the siting, design, materials, access, and installation of manufactured dwellings, accessory

More information

Georgia Association of Home Inspectors

Georgia Association of Home Inspectors Georgia Association of Home Inspectors Standards of Practice for Framing Inspections OVERVIEW The purpose of the GAHI (Georgia Association of Home Inspectors) Standards of Practice for Framing Inspections

More information

October 30, 2014. Mr. & Mrs. Daniel Vick 101 Southwind Cove Benton, AR. Report of Findings, Structural Investigation, Benton, Arkansas, Dear Mr.

October 30, 2014. Mr. & Mrs. Daniel Vick 101 Southwind Cove Benton, AR. Report of Findings, Structural Investigation, Benton, Arkansas, Dear Mr. 117 S. Market St. Benton, AR 72015 * 501-315-2626 * Fax 501-315-0024 October 30, 2014 Mr. & Mrs. Daniel Vick 101 Southwind Cove Benton, AR Re: Report of Findings,, Benton, Arkansas, Dear Mr. Vick: This

More information

Vision Home Inspection

Vision Home Inspection Vision Home Inspection 324 Rams Run Shepherdsville KY 40165-7877 Inspector: James McFadden Property Inspection Report Client(s): Property address: Inspection date: View report summary This report is the

More information

8/18/14. Introduction to. Framing. Terminology and Concepts

8/18/14. Introduction to. Framing. Terminology and Concepts 8/18/14 Introduction to Framing Terminology and Concepts Terminology: Framing Level Two points on exactly the same horizontal plane. Square Intersecting lines or faces that form an exact 90 angle. Plumb

More information

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM Chapter 9 STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM 9.1 BACKGROUND Steel is widely used in the construction of multi-storey buildings. However, steel construction is seldom used and is traditionally

More information

Page & Turnbull imagining change in historic environments through design, research, and technology

Page & Turnbull imagining change in historic environments through design, research, and technology DCI+SDE STRUCTURAL EVALUATIONS OFFICE BUILDING, TOOL SHED & WATER TANK, AND BLACKSMITH & MACHINE SHOP BUILDINGS SAN FRANCISCO, CALIFORNIA [14290] PRIMARY PROJECT CONTACT: H. Ruth Todd, FAIA, AICP, LEED

More information

Foundation. Foundation

Foundation. Foundation Moisture Aside from structural concerns, the most important consideration for foundation design is moisture. No client wants a wet basement. No client wants a damp basement. No client wants mold in their

More information

Asphalt Shingle Application Requirements

Asphalt Shingle Application Requirements Alberta Allied Roofing Association Asphalt Shingle Application Requirements Section 1 Roof Decks 1.1 General Asphalt Shingles are not permitted to be installed directly over rigid insulation. When Asphalt

More information

The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs

The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs The better way to build TM Installation Manual FOUNDATION SIPs & FROST WALLS SIPs February 2016 PWF FOUNDATION & FROST WALL SIPs Installation Manual Table of Contents Topics General Requirements...................................

More information

2014 FLORIDA BUILDING CODE

2014 FLORIDA BUILDING CODE MINIMUM REQUIREMENTS FOR NEW 1 & 2 FAMILY RESIDENTIAL STRUCTURES (ALL PLANS MUST BE 22 X 36 ) WIND BORNE DEBRIS AREA Is the proposed structure located in the wind borne debris area? If yes, one of the

More information

Footing and Temporary Power Inspection

Footing and Temporary Power Inspection Footing and Temporary Power Inspection Address: Date: Permit #: Inspector: # General Code Sec. OK C* Number, Location and Remarks 1 Permit posted on site Local 2 Port-o-let Local 3 Setbacks - front, sides,

More information

INSTALLATION OF A BAY WINDOW

INSTALLATION OF A BAY WINDOW INSTALLATION OF A BAY WINDOW Installation of a Bay Window These instructions relate to the replacement of an existing bay window or replacement of a straight window with a new bay window, in an opening

More information

Foundation Experts, LLC Specializes in Foundation Repair and Waterproofing

Foundation Experts, LLC Specializes in Foundation Repair and Waterproofing 1 Most basements show some signs of leaking and cracking. Through the years, problems with water, poor soils, grading, drainage and possible settling affect the integrity of a basement. Being able to recognize

More information

6 RETROFITTING POST & PIER HOUSES

6 RETROFITTING POST & PIER HOUSES Retrofitting Post & Pier Houses 71 6 RETROFITTING POST & PIER HOUSES by James E. Russell, P.E. 72 Retrofitting Post & Pier Houses Retrofitting Post & Pier Houses 73 RETROFITTING POST AND PIER HOUSES This

More information

Chapter 6 ROOF-CEILING SYSTEMS

Chapter 6 ROOF-CEILING SYSTEMS Chapter 6 ROOF-CEILING SYSTEMS Woodframe roof-ceiling systems are the focus of this chapter. Cold-formed steel framing for a roof-ceiling system also is permitted by the IRC but will not be discussed;

More information

SUPER SHED. Indoor shelter for your outdoor tools.

SUPER SHED. Indoor shelter for your outdoor tools. SUPER SHED Indoor shelter for your outdoor tools. Not everyone needs a garden shed. But, if you've no more space on your garage wall for that new leaf rake, if you can't find your potting trowel because

More information

Self-Home Inspection Checklist

Self-Home Inspection Checklist To be used as a first home visit for note taking. Visit www.homeinspectiondirect.com for more tips and information about buying a home and hiring a home inspector. This form in no way replaces a professional

More information

Chapter 36 - STRAW BALE CONSTRUCTION SECTION 3601 - PURPOSE. SECTION 3602 - SCOPE. SECTION 3603 - DEFINITIONS.

Chapter 36 - STRAW BALE CONSTRUCTION SECTION 3601 - PURPOSE. SECTION 3602 - SCOPE. SECTION 3603 - DEFINITIONS. Austin City Code - Volume II TITLE 25 LAND DEVELOPMENT\CHAPTER 25-12 TECHNICAL CODES\ARTICLE 1: UNIFORM BUILDING CODE\25-12-3 LOCAL AMENDMENTS TO THE BUILDING CODE Chapter 36 - STRAW BALE CONSTRUCTION

More information

COMMONLY USED RESIDENTIAL BUILDING CODES

COMMONLY USED RESIDENTIAL BUILDING CODES COMMONLY USED RESIDENTIAL BUILDING CODES INTERNATIONAL RESIDENTIAL CODE (2009) form revised 5/10 FOUNDATION 1. DESIGN OF FORMWORK. Section 1906.1 IBC 2009, Section R404.1.2.3.6 IRC 2009, ACI 318 Section

More information

www.citiesinspection.com October 5, 2015 Dear Client,

www.citiesinspection.com October 5, 2015 Dear Client, www.citiesinspection.com October 5, 2015 Dear Client, On 9/14/2015, Cities Inspection Service, Inc. completed a building inspection of the property located at 123 Oak Street, Someplace, Minnesota for you.

More information

CONSTRUCTION DETAILS & LOAD DESIGN CHARTS

CONSTRUCTION DETAILS & LOAD DESIGN CHARTS Office and Production 126 New Pace Rd., PO Box 279 Newcomerstown, OH 43832 1-800-446-2188, Fax: 740-498-4184 www.buildwithsips.com CONSTRUCTION DETAILS & LOAD DESIGN CHARTS Table of Contents Description

More information

AMERICAN GOTHIC PLAYHOUSE

AMERICAN GOTHIC PLAYHOUSE AMERICAN GOTHIC PLAYHOUSE Project Plan #856 Sheet 1 of 5 Pick a spot and get started with the beautiful that your kids will love. The design of the playhouse includes 35 square feet of interior space plus

More information

Does Wall Township require an inspection by the building department on resale of a home?

Does Wall Township require an inspection by the building department on resale of a home? Selling your home Does Wall Township require an inspection by the building department on resale of a home? No. We do not require a Certificate of Continued Occupancy on the resale of home. A Smoke Detector,

More information

City of Tucson and Pima County Arizona Building Code Appendix Chapter 72 Straw-Bale Structures

City of Tucson and Pima County Arizona Building Code Appendix Chapter 72 Straw-Bale Structures City of Tucson and Pima County Arizona Building Code Appendix Chapter 72 Straw-Bale Structures SECTION 7201 - PURPOSE The purpose of this appendix chapter is to establish minimum prescriptive standards

More information

Free 12 x 8 Shed Plan With Illustrations, Blueprints & Step By Step Details

Free 12 x 8 Shed Plan With Illustrations, Blueprints & Step By Step Details Free 12 x 8 Shed Plan With Illustrations, Blueprints & Step By Step Details Brought To You By: MyShedPlans Click Here To Download 12,000 Shed Plans >> 12 x 8 Basic Shed This 8 12-ft. shed features a simple

More information

REQUIREMENTS FOR SUBMITTING PLANS FOR NEW CONSTRUCTION

REQUIREMENTS FOR SUBMITTING PLANS FOR NEW CONSTRUCTION RESIDENTIAL: REQUIREMENTS FOR SUBMITTING PLANS FOR NEW CONSTRUCTION 2 COMPLETE SETS OF PRINTS WITH ENGINEERS STAMP ON FOUNDATION PLAN INCLUDING ELECTRICAL, PLUMBING, ETC. SITE PLAN SHOWING HOUSE LOCATION

More information

RESIDENTIAL FOUNDATION GUIDELINE Johnson County, KS

RESIDENTIAL FOUNDATION GUIDELINE Johnson County, KS RESIDENTIAL FOUNDATION GUIDELINE Johnson County, KS Johnson County Building Officials Association January 2008 Residential Foundation Guideline Foundation designs for one-and two-family dwellings may use

More information

Sample Drawing Package for One and Two Family Dwelling Applications

Sample Drawing Package for One and Two Family Dwelling Applications Sample Drawing Package for One and Two Family Dwelling Applications For a full list of submission requirements, refer to the relevant checklist for your application found on our website: http://vancouver.ca/home-property-development/application-forms-and-checklists.aspx

More information

Installation Instructions Double-Hung, Single-Hung, Casement, Awning, Sliding, Picture & Shapes Non-Impact & Impact Resistant Nailing Fin Windows

Installation Instructions Double-Hung, Single-Hung, Casement, Awning, Sliding, Picture & Shapes Non-Impact & Impact Resistant Nailing Fin Windows Installation Instructions Double-Hung, Single-Hung, Casement, Awning, Sliding, Picture & Shapes Non-Impact & Impact Resistant Nailing Fin Windows americancraftsmanwindows.com Project Requirements: Read

More information

CITY OF FAIRFAX CODE ADMINISTRATION 703-385-7830 / FAX 703-385-9265 www.fairfaxva.gov

CITY OF FAIRFAX CODE ADMINISTRATION 703-385-7830 / FAX 703-385-9265 www.fairfaxva.gov CITY OF FAIRFAX CODE ADMINISTRATION 703-385-7830 / FAX 703-385-9265 www.fairfaxva.gov Finishing a basement to make additional living space in a house is a popular construction project for many homeowners.

More information

CITY OF SELMA, TEXAS Inspection Checklist: Commercial

CITY OF SELMA, TEXAS Inspection Checklist: Commercial Rev Y71004 The Permits and Inspections Department welcomes you to the City of Selma. The following information is provided to you as guidance through the inspection process. The City of Selma provides

More information

ROOF CONSTRUCTION Roof Styles Gable Roof Hip Roof Gambrel Roof

ROOF CONSTRUCTION Roof Styles Gable Roof Hip Roof Gambrel Roof ROOF CONSTRUCTION The overall appearance of a building is greatly affected by the roof lines and the roofing materials. The designer has many standard designs to choose from and should be able to find

More information

Best Barns USA Assembly Book

Best Barns USA Assembly Book Best Barns USA Assembly Book Revised November 27, 2013 the Easton - R 12'x 20' Manufactured by Reynolds Building Systems, Inc. 205 Arlington Drive Greenville, PA 16125 724-646-3775 This manual is copyrighted.

More information

BUILDING PERMIT SPECIFICATIONS

BUILDING PERMIT SPECIFICATIONS BUILDING PERMIT SPECIFICATIONS The below noted requirements are based upon La Plata County Building Code. These specifications are not intended as a complete set of requirements, but are intended to provide

More information

BUILDING SAFETY UNIT

BUILDING SAFETY UNIT POLICY Page 1 of 5 SUBMITTAL REQUIREMENTS FOR ONE AND TWO FAMILY DWELLINGS, ADDITIONS AND RENOVATIONS All submittals shall be site specific and designed to the provisions of the 2012 International Residential

More information

Window Installation Instructions

Window Installation Instructions Caution The correct installation methods of windows in full frame or insert applications is critical towards achieving the tested performance of the window and longterm enjoyment and energy savings for

More information

The Closed Crawl Space: Making the Transition Climate Zones 3A & 4A

The Closed Crawl Space: Making the Transition Climate Zones 3A & 4A TechSpecs A builder s blueprint for construction technologies January 2013 The Closed Crawl Space: Making the Transition Climate Zones 3A & 4A C B A E D H G F A. Wood Floor Framing - p. 2 B. Foundation

More information

Sun Windows General Information Sun New Construction Window Installation Instructions

Sun Windows General Information Sun New Construction Window Installation Instructions Sun Windows General Information Section 1 G F H H H A. Apply Weather Resistive Barrier B. Apply Sill Flashing Tape C. Place Waterproof Sill Shims D. Caulk Back of Nail Fin Sides & Top, Set Window, Fasten

More information

We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden window unit.

We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden window unit. Important Information for New Construction Installations Attention Installer! We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden

More information

Proposed Minimum Subterranean Termite Treatment Standards

Proposed Minimum Subterranean Termite Treatment Standards Proposed Minimum Subterranean Termite Treatment Standards Introduction This document is intended to serve as a model for states considering the adoption of standards for soil application of termiticides.

More information

Holz Choices & Specifications

Holz Choices & Specifications March 21, 2011 0. SALES AND DESIGN 1. UTILITIES AND PERMITS Holz Choices & Specifications 2. EXCAVATION AND LOT PREPARATION Job Beginning date of Monday May 2 nd, 2011 ALTERNATE: Garage walls as drawn

More information

TORO STEEL BUILDINGS. BOLTS: o - 0.635" diam. x - 0.75 " diam. x - 1.00 " diam. C.J. - Control Joints to minimize cracking.(0.

TORO STEEL BUILDINGS. BOLTS: o - 0.635 diam. x - 0.75  diam. x - 1.00  diam. C.J. - Control Joints to minimize cracking.(0. 100 ' 0 " out to out of steel C 1 ' 3.25 " B Keep This Distance 37 ' 5.5 " ll sections and bolts have been blown up for clarification of placement. They are to be centered as much as possible on pier.

More information

TYPICAL PATIO COVERS 111

TYPICAL PATIO COVERS 111 City of Laguna Niguel Building Division 30111 Crown Valley Pkwy Laguna Niguel, CA 92677 (949) 362-4360 FAX 362-4369 www.cityoflagunaniguel.org TYPICAL PATIO COVERS 111 PLEASE NOTE: This information Bulletin

More information

Total Home Inspection Checklist

Total Home Inspection Checklist Total Home Inspection Checklist Use a checklist like this to make sure that you are looking at all parts of the house. Check off those items that are in good condition and make notes about those that are

More information

2014 British Columbia Building Code Changes

2014 British Columbia Building Code Changes District of Houston 250-845-2238 2014 British Columbia Building Code Changes A District of Houston interpretation of the 2014 Building Code Changes for 9.36 & 9.32 The following changes reflect the most

More information

Common Problems with Walls

Common Problems with Walls Common Problems with Walls Common Problems with Walls There are problems and concerns that are shared by all walls and siding installations. In this article, we will learn about the following commonly

More information

CLIENT. Inspection Report. 271 Front St. Alert Bay, B.C. Island Building Inspections V ANCOUVER I SLAND B. C.

CLIENT. Inspection Report. 271 Front St. Alert Bay, B.C. Island Building Inspections V ANCOUVER I SLAND B. C. CLIENT Inspection Report 271 Front St. Alert Bay, B.C. Island Building Inspections 2013 V ANCOUVER I SLAND B. C. Elevation Photos For the Property at 271 Front Street Alert Bay, BC ELEVATION PICTURES Front

More information

The Lambton County Homeowner's BUILDING PERMIT INFORMATION GUIDE

The Lambton County Homeowner's BUILDING PERMIT INFORMATION GUIDE The Lambton County Homeowner's BUILDING PERMIT INFORMATION GUIDE BUILDING SERVICES DEPARTMENT 789 Broadway Street, Box 3000 Wyoming, ON N0N 1T0 Telephone: 519 845-0801 Toll-free: 1-866-324-6912 Fax: 519

More information

Building Condition Assessment Report

Building Condition Assessment Report C2 - Nurses Resident (aka Administration) Building Condition Assessment Report Asset Address Address Construction Year Size (Gross Floor Area) Asset Type Floors Above Ground Inspection Date C2 - Nurses

More information

How To Repair A Boat Landing Deck With A Boat Bed

How To Repair A Boat Landing Deck With A Boat Bed RESIDENTIAL INSULATED SHEATHING INSTALLATION GUIDE Residential Insulated Sheathing Installation Guide ROXUL COMFORTBOARD IS Table of Contents Slab-on-grade-to Above Grade Wall...1 Foundation Wall at Footing

More information

Home Inspection Report

Home Inspection Report Report# 21009 Page 1 of 24 Home Inspection Report Property Address: 123 Maple Lane, St. Augustine, FL 32092 Prepared For: Mr. Smith Prepared By: EDGE Inspections www.edgeinspections.com PO Box 601055 Jacksonville,

More information

PART 1 GENERAL 1.1 SECTION INCLUDES

PART 1 GENERAL 1.1 SECTION INCLUDES J-1 Section 09110 Long Form Specification INTERIOR METAL STUD FRAMING This section includes lightweight, usually 0.036 inch (0.9 mm) thick or lighter, non-axial load bearing metal stud framing including

More information

INFORMATION BULLETIN NO.

INFORMATION BULLETIN NO. Requirements for Plans Review Submittal, One- and Two-Family Dwellings INFORMATION BULLETIN NO. 100 (June 26, 1998, Revised March 26, 2009) City Planning & Development - Development Services City of Kansas

More information

EAST LYME HIGH SCHOOL

EAST LYME HIGH SCHOOL Overview: 1971 N 1966 GYM 1966 CLASSROOM WING 1966 AUD. 1971 GYM 1998 1998 POOL EAST LYME HIGH SCHOOL Original 1966 Building: The original East Lyme High School was constructed in 1966 and was composed

More information

Residential Deck Safety, Construction, and Repair

Residential Deck Safety, Construction, and Repair Juneau Permit Center, 4 th Floor Marine View Center, (907)586-0770 This handout is designed to help you build your deck to comply with the 2006 International Residential Building code as modified by the

More information

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 SECTION R905 REQUIREMENTS FOR ROOF COVERINGS R905.1 Roof covering application. Roof coverings

More information

ENERGY STAR Qualified New Homes Thermal Enclosure Checklist. Water Management Checklist. Eli Caudill

ENERGY STAR Qualified New Homes Thermal Enclosure Checklist. Water Management Checklist. Eli Caudill ENERGY STAR Qualified New Homes Thermal Enclosure Checklist & Water Management Checklist Eli Caudill ENERGY STAR Version 3 Tighter Standards Whole Home Approach Better, More Sustainable Construction Surpasses

More information

HomeSpec REPORT SUMMARY

HomeSpec REPORT SUMMARY HomeSpec 04/25/2007 Ms. Rachel Trujeque Re: 13038 West Plum Road Lot #1225 - Peoria, AZ. 85383 - Pre Drywall Inspection Dear Ms. Trujeque, At your request, a visual pre drywall inspection of the above

More information

Patio Covers / Carports

Patio Covers / Carports Patio Covers / Carports Building Guides for Homeowners Why Do I need a Permit? D I D Y O U K N O W? As owner-builder you are the responsible party of record on such a permit. If your work is being performed

More information

How To Repair A House

How To Repair A House Assessing Structural Damages Please note-this presentation is only intended to be used as a basic educational tool and is by no means all encompassing. Each property should be treated on a case by case

More information

State of Connecticut Department of Public Health RADON PROGRAM

State of Connecticut Department of Public Health RADON PROGRAM State of Connecticut Department of Public Health RADON PROGRAM Scope The Connecticut Department of Public Health (DPH) Radon Program is providing this information for contractors who decide to build radon

More information

ADDENDUM # 1 To: 1112-909-62-3698 RFP for: Various Construction Maintenance & Repair Services

ADDENDUM # 1 To: 1112-909-62-3698 RFP for: Various Construction Maintenance & Repair Services 818 S. FLORES ST. SAN ANTONIO, TEXAS 78204 www.saha.org Procurement Department ADDENDUM # 1 To: 1112-909-62-3698 RFP for: Various Construction Maintenance & Repair Services Remove and replace in their

More information

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016. Underground branch circuit feeding a detached garage:

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016. Underground branch circuit feeding a detached garage: Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016 * Garage construction requires permits (electrical, building) * Permits must be applied for at the time. * Dial

More information

When is a Permit Required? What Types of Permits are Required? The most common types of projects that require permits are:

When is a Permit Required? What Types of Permits are Required? The most common types of projects that require permits are: When is a Permit Required? The most common types of projects that require permits are: -New Houses or buildings -Room Additions or Expansions -Structural repairs, remodeling and alterations -Accessory

More information

ONE-STOP S PERMIT INFORMATION PACKAGE FOR RESIDENTIAL PROJECTS

ONE-STOP S PERMIT INFORMATION PACKAGE FOR RESIDENTIAL PROJECTS ONE-STOP S PERMIT INFORMATION PACKAGE FOR RESIDENTIAL PROJECTS This package was prepared by the Meet & Greet Office 1002 Washington Avenue 1 st Floor Houston, TX 77002 Phone: 832-394-9000 TABLE OF CONTENTS

More information

How To Build A Basement House

How To Build A Basement House Single Family Basement Finish Purpose of Guide The purpose of this guide is to assist you in the permit process for your project. This handout is intended as a basic plan submittal under the 2009 International

More information

Uncovered Decks & Porches

Uncovered Decks & Porches Uncovered Decks & Porches Building Guides for Homeowners Why Do I need a Permit? D I D Y O U K N O W? As owner-builder you are the responsible party of record on such a permit. If your work is being performed

More information

BUILDING IN ALASKA HCM-00952

BUILDING IN ALASKA HCM-00952 BUILDING IN ALASKA HCM-00952 Building Challenges in Alaska INTRODUCTION Special considerations for building in Alaska are recommended that are normally not included in structures designed for milder climates

More information

Guidelines for Earthquake Bracing of Residential Water Heaters

Guidelines for Earthquake Bracing of Residential Water Heaters Guidelines for Earthquake Bracing of Residential Water Heaters Department of General Services Division of the State Architect 1102 Q Street, Suite 5100 Sacramento, CA 95814 Phone: (916) 324-7099 Fax: (916)

More information

WOODLAND HOMES BUILDING PROCESS A STEP BY STEP CONSTRUCTION GUIDE TO YOUR NEW HOME

WOODLAND HOMES BUILDING PROCESS A STEP BY STEP CONSTRUCTION GUIDE TO YOUR NEW HOME WOODLAND HOMES BUILDING PROCESS A STEP BY STEP CONSTRUCTION GUIDE TO YOUR NEW HOME 1 THE BUILDING PROCESS The focus of Woodland Homes building department is Quality, Service and Predictability. Through

More information

Estimated Cost of Repair

Estimated Cost of Repair 1 Applicant: Property: Home: Business: Assessor: Applicant Number: Type of Loss: Hurricane Date Contacted: 1/18/2014 Date of Loss: 10/29/2012 Date Received: 1/14/2014 Date Inspected: 2/4/2014 Date Entered:

More information

Introduction...COMB-2 Design Considerations and Examples...COMB-3

Introduction...COMB-2 Design Considerations and Examples...COMB-3 SECTION DIRECTORY General Information Introduction...COMB-2 Design Considerations and Examples...COMB-3 Combination Assembly Recommendations and Limitations Composite Configurations...COMB-4 Typical Sealant

More information

A0 SHEET 1 OF 5 400 LOCUST STREET FRANKFORT, KANSAS 66427 FRANKFORT, KANSAS 66427 ROOF REPAIR OF THE 400 LOCUST STREET

A0 SHEET 1 OF 5 400 LOCUST STREET FRANKFORT, KANSAS 66427 FRANKFORT, KANSAS 66427 ROOF REPAIR OF THE 400 LOCUST STREET POYNTZ AVENUE, STE 9 MANHATTAN, KS 0..0..9 FAX WEST th STREET JUNCTION CITY, KS.... FAX 0, Bruce McMillan AIA, Architects, P.A. HERITAGE TRUST FUND GRANT PROJECT NO. 0-0 ROOF REPAIR OF THE 00 LOCUST STREET

More information