1 residential concrete detailing and specification guide

2 residential concrete detailing and specification guide

3 preface This technical manual is published by the Cement & Concrete Association of New Zealand with funding assistance from the New Zealand Concrete Masonry Association. The construction details contained within this manual have been developed based on extensive research both locally and internationally. They are designed to give examples representative of good practice, rather than a complete range of possible alternatives. The manual is written by Morten Gjerde, Lecturer and CCANZ Fellow at Victoria University of Wellington, School of Architecture. Heartfelt thanks to the following people, without whose assistance this would not have been possible: Research assistance: Rachel Chan Peter Lough Oliver Markham Nancy Bakker Grant Taylor Peer review: Daniel Bagust Philip Blair Ross Cato John Gibbons Derek Lawley Nigel Marshall Andy Wilton Typing: Tricia Hawkins Editing: Grant Thomas Dene Cook Waterproof with us Resene X-200 Acrylic Waterproofing Membrane occupies pride of place in the Resene range of waterproofing products. With Resene X-200, most surfaces can be waterproofed and weatherproofed with a two-coat system*. Application costs are therefore similar to any two coats of conventional paint, combined with the benefits of multi coat high build systems. Resene X-200 uniquely combines low viscosity with high build ensuring excellent penetration into cracks and pores, resulting in superb adhesion. Resene X-200 high build properties allow the development of a tough, durable and continuous membrane, while nonasbestos fibre reinforcement increases tensile strength. Resene also manufactures and sells a full range of textured coatings and specialist finishes to give you and your client the finish you desire. From high builds to aggregate textured coatings, we have the range to suit every taste. To find out more and obtain copies of the X-200 Data Sheet (D62) or textured coatings and specialist finishes specifications (21e/i), call 0800 RESENE ( ), see your nearest Resene ColorShop, or visit the Resene website at * An additional coat of X-200 may be required on concrete block due to regional variations in standards. 3

4 contents General Information Concrete Masonry Insulating Concrete Formwork Precast Concrete Concrete Cast In-Situ References ISBN TM36 Cement & Concrete Association of New Zealand Level 6, 142 Featherston St, Wellington. P O Box 448, Wellington. Tel: (04) , Fax: (04) [email protected] Cement & Concrete Association of New Zealand 2000 Except where the Copyright Act allows, no part of this publication may be reproduced, stored in any retrieval system in any form, or transmitted by any means, without the prior permission in writing of the Cement & Concrete Association of New Zealand. The information provided in this manual has been prepared with all due care; however the Cement & Concrete Association of New Zealand accepts no liability arising from its use. 5

5 residential concrete detailing and specification guide Mann House in Auckland by Ian Juriss. 6

6 General Information General Information introduction Concrete is well known to many New Zealanders as a building material. Being a country of doers has meant that not only are we familiar with concrete but also many have had personal experience with it. Footpaths, garden walls, garages and sculptures stand as testament to this hands-on experience. In the construction industry, concrete is the most widely used material both here and overseas. Commercial structures from single to multi-storey continue to be built in concrete. Most residential construction is based on the concrete ground floor slab and our infrastructure, from underground pipes to bridges, is largely constructed of the material. The building industry in New Zealand is well resourced to construct in concrete. Raw materials are readily available throughout the country. The techniques for constructing formwork, placing concrete, erecting precast elements and building in masonry are to a very high standard internationally. The design of concrete structures by local engineers lead the world in many areas. The existence of several quality suppliers of precast structural systems and other proprietary elements in the marketplace allow designers and builders competitive pricing, extensive system choice and excellent technical support. For all that, New Zealanders continue to favour timber framing for the construction of their houses. It is not unusual to see a design modelled on the massive homes of the Mediterranean, built using spaced timber studs with a thin cladding of stucco or acrylic plaster on rigid board. Many designers and homeowners in this country prefer to continue to use systems and techniques with which they are familiar. Concrete construction has been widely used for housing throughout Europe and to a lesser extent in the United States. It would be difficult to think of the work by Le Corbusier, Adolf Loos and more recently Herzog and demuron without conjuring up images of concrete. Market research has been carried out in an effort to identify why concrete is not used more readily in the residential construction sector in New Zealand. These results indicates that there is inadequate information for those wanting to design and build concrete houses. There is also a lack of builders who are comfortable building concrete walls and suspended floors in the domestic context. The processes involved in building in concrete are different to those employed in timber framing and cladding. Builders comfortable with concrete have tended to become established in commercial construction. While the research pointed to an enthusiasm for concrete homes, designers and builders tend to stay with familiar materials and processes. This publication seeks to bridge the knowledge gap for designers and builders of concrete homes. It does not however claim to fulfil all their information needs. It has been structured to give an overview of the principles and highlight the critical issues facing designers and builders. The construction industry has been widely consulted and research has been carried out both locally and internationally. The details have been prepared to present a broad range of construction scenarios. The designer or the builder using this manual may find the need to change relationships or sizes shown to suit their own purposes. The intention has been to present a starting point from which specific details can be developed. The details shown here have been checked for suitability for New Zealand conditions. Provided the detailing principles are adhered to, others should perform equally well. The raw materials for concrete are readily available. 7

7 residential concrete detailing and specification guide Recessed timber door & sill Butyl rubber sill flashing Non structural conc. veneer Insulation Paving level Structural conc. panel SILL DETAIL Floor coverings Reinforced conc. slab scope This document has been prepared as a general guide to the design and construction of the single family house and projects of similar scale in New Zealand. Although this manual does not specifically address fire resistance and sound transmission ratings, the adjacent table demonstrates the values that can be achieved with appropriate detailing. It presents materials and systems that are commonly available in New Zealand. Some, such as timber joinery and concrete itself, have been in use for several generations. Others have recently come into the local market and industry experience with some of these may be limited. On the other hand, building products not available in New Zealand have not been incorporated. To do so would inaccurately present the range of materials available here. The construction, specification and detailing issues are presented in the New Zealand context. We have specific and often unique ways of doing things. The New Zealand environmental conditions are also unique. This book is principally concerned with design and construction issues. While it does touch upon topics such as thermal performance and structural engineering, it is not meant to serve as a guide in these areas. Structural design is still best left to the professionals except in those areas where non-specific design standards are available. Concrete masonry is one such format with NZS 4229 having been revised in The Cement & Concrete Association of New Zealand produces a range of other publications that may be of interest to the designers and builders of concrete homes. Further information is available at Panel Thickness Fire Rating Sound Transmission Class (STC) rating 100 mm 90 minutes mm 120 minutes mm 180 minutes mm >240 minutes 58 Typical fire and sound transmission ratings that can be achieved with concrete systems when appropriately detailed. 8

8 detailing considerations Objectives Successful architectural detailing requires attention to many factors. As with most aspects of building, it is often necessary to think laterally to achieve results that are both poetic and satisfy pragmatic goals. First off, it is important to be able to clearly identify the detailing objectives. These may come under headings such as: cost appearance and aesthetics buildability materials usage routine maintenance All successful design and detailing efforts will consider these factors. The designer may make value judgments through the process, placing the importance of one aspect above another. The critical thing is to be aware of these considerations and to understand the consequences of favouring any one over the other. Environment It is also important to consider the specific environment that the details are to exist in. It is critical to acknowledge and design for: prevailing winds and wind patterns created by the landscape or other buildings rain and other weather that can be expected UV exposure dust and pollutants that may be in the air and settle on the building corrosive elements in the air such as salt spray moisture, either rising from the ground, or as general humidity Specific environments can vary from site to site and even on different faces of the same building. While exposed concrete masonry may be appropriate on the sunny north face of a house, its use on the south side of a damp site could quickly see mould and other organic growth develop, even with regular cleaning. If inappropriate materials are used or poor detailing choices are made, the building appearance can deteriorate quickly. Material properties Concrete has a number of special and unique qualities that make it an ideal construction medium, particularly in domestic applications. These include: high durability thermal mass benefits when used appropriately ability to form and shape enclosure of space and structure in one material ability to form integral surface finishes and colour relatively inert and compatible with most other buildings materials excellent acoustic and fire resistant properties Along with these qualities are some inherent limitations that the designer should bear in mind: Grigg House by Miles Warren. Frank Lloyd Wright was an innovator with concrete. 9

9 residential concrete detailing and specification guide once cast it is difficult to change not sufficiently waterproof on its own sharp corners or edges can be vulnerable to mechanical damage Once the decision to use a concrete structure in residential projects is made, the designer and the builder must find ways of optimising the positive attributes while minimising the negative aspects of concrete. The best way of ensuring this is through adequate and considered planning. This Guide is one resource to help with this planning. Maintenance Planning for routine maintenance of the building, and in particular of the details, must be borne in mind. All materials and details perform better when they are maintained. Such maintenance may include washing, replacement of seals and sealants and re-application of waterproofing coatings. Sargent House in Auckland by Ron Sang Decisions made by the builder or designer may place high demands on the homeowner to maintain certain details. Often the homeowner is not consulted or considered at the time, a point that is particularly true of homes built speculatively. Homeowners, where appropriate, should be consulted with over maintenance issues. In all cases, they should be made aware of routine maintenance requirements. The lifetime success of the project will benefit. An example of exposed aggregate finish. 10

10 General Information moisture control Concrete, although used in the construction of water tanks, is not generally considered to be sufficiently waterproof for housing without supplementary waterproofing systems. Not only is concrete water permeable, it also contains excess water from the construction process that must be allowed to escape. This moisture can, if not dealt with, continue to plague the homeowner. As a rule of thumb concrete requires one month per 25 mm of thickness to dry (from each exposed face) assuming dry conditions. This means that under ideal conditions a 100 mm thick concrete wall will require two months drying time if both faces are left exposed for that period. Finishes that are applied to exterior surfaces of concrete which have not dried adequately, may be affected by the tendency of water to escape to the warm side. This could lead to bubbling of the surface finish. The external moisture clauses of the New Zealand Building Code are increasingly being complied with through the use of painted membrane systems. These systems are continuing to develop and there are a number that have proven records in New Zealand conditions. Their use has increased the options for designers but at the same time designers must ensure that sound detailing and building principles are not ignored. If a strategy of reliance on painted membrane systems has been adopted, it is advisable to thoroughly investigate the systems under consideration. Speak to those who have applied the products and have experience of their performance. Also obtain test results and manufacturer s guarantees of performance. This house will be left unpainted until all construction moisture has escaped. Internal moisture control is often not considered by designers but is critical to the comfort and enjoyment of the home. The best method of assuring that the concrete home performs well in this regard is to insulate well and to specify appropriate finishes in those rooms where high moisture levels can be anticipated. The enjoyment of a well designed concrete home will be enhanced by the designer considering the environment, material properties and sound detailing principles. thermal performance and insultation Thermal mass within the building envelope can provide significant benefits in terms of both energy efficiency and comfort. Maximising the thermal mass benefits of concrete requires consideration of a number of issues including: site and building location and orientation, insulation placement, glazing placement and orientation, and usage patterns, to mention a few. This manual does not attempt to cover issues which need to be considered in maximising the benefits of thermal mass. Designers wishing to check thermal properties of concrete homes for code compliance should refer to two New Zealand standards: NZS 4214 provides the means of calculating the thermal resistance of building elements, and NZS 4218 defines minimum requirements for the various elements of a house (ie walls, roof, floor). A contemporary concrete house. 11

11 Concrete Masonry Concrete Masonry General Design Issues Specification Construction Details

12 Concrete Masonry Concrete masonry or blockwork has a long association with residential construction in New Zealand. As well as offering all the positive attributes of the other forms of concrete it is an easy format to use. The use of concrete masonry has been well supported by the block manufacturers throughout the country. Special profiles are available to suit all the detailing conditions that can be anticipated. The range of products continues to be expanded as blocks with special surface finishes, sizes and thermal characteristics are put to the market. In effect concrete masonry is a type of permanent formwork for concrete. The grout fill working in conjunction with the reinforcing steel provides the structural strength. New research carried out by New Zealand universities has lead to a reduction in the amount of horizontal reinforcing steel and grout fill required. 140 mm wide (15 Series) concrete masonry has also been shown to be structurally appropriate for most residential projects. These changes have been incorporated into the recently released update of NZS 4229:1999, the Standard for non-specific concrete masonry design. Advantages of concrete masonry economy particularly when the construction module is fully exploited does not require special or costly equipment to install modular units are relatively easy to handle and can be delivered to most buildings sites stop and start of construction is easy to incorporate structurally and architecturally range of profiles allowing for most detailing requirements interesting architectural scale and surface textures The qualities and advantages of concrete masonry certainly make it an appealing material to consider for residential construction. Until the nineteen -seventies New Zealand houses built of blockwork used cavity wall construction techniques. Concrete masonry is more porous than most other forms of concrete. The blocks themselves are permeable, particularly when they are manufactured using the lightweight pumice aggregate typical of the upper half of the North Island. It is however the mortar joints which are the real culprit. As the mortar dries and shrinks, cracks develop against adjoining blocks. Traditional cavity wall construction assumes moisture will be able to penetrate the outer skin, but then drop to the bottom of the cavity and out through weep holes without affecting the inner skin. The outer skin of the wall also serves to conceal the waterproofing membrane on the outer surface of the inner skin. Time pressures and increases in the cost of construction have meant that this effective traditional method of construction has generally been replaced by the single skin masonry wall. As has been discussed earlier in this guide the change has been justified through the development of new materials which effectively seal the external surfaces while also serving as paint or plaster finishes. This is often in conjunction with rigid insulation. NZS 4229: 1999 has adopted the use of acrylic membranes as appropriate waterproofing solutions. Broderick House by Warren & Mahoney 15

13 residential concrete detailing and specification guide design issues Modular setout Common mortar joint profiles raked flush While other forms of concrete construction allow freedom of shape and size, the modular nature of blockwork directs many design considerations. For reasons of economy and ease of construction, the modular height of units typically 100 mm or 200 mm should be adhered to. This applies to overall heights of walls as well as openings within walls. Sticking to a running module of 200 mm will provide economy, however, the length of units can be easily cut. If the module is seen, the designer may wish to specify the position of the cut units. Joints struck weathered The mortar joint between blocks has a number of functions. Its primary function is to bond adjoining blocks together. This is a permanent requirement for those blocks that are not to have filled cores. The grout fill will otherwise take over as the bonding mechanism. Another function of the joint is to take up construction or manufacturing tolerances as slight variations in block sizes may occur. Finally the joint contributes significantly to the appearance of the concrete masonry wall. The industry norm of a 10 mm joint is generally considered to be a good proportion when compared to the individual masonry unit. This width can be varied by the designer to suit particular requirements. When blockwork is designed to be left exposed, the colour of the joint is a consideration. It is, however, the profile which offers the designer the greatest number of variations to suit aesthetic or weathering requirements. vee concave Profiles of typical joints that can be specified are shown in the illustration to the left. Combining joint profiles, such as alternating flush with struck to suggest a different module, or raked horizontals and flush vertical joints can be effective. Bonding patterns The way in which the concrete blocks are laid presents another opportunity to affect the overall appearance of a wall. The traditional bonding pattern for concrete masonry is the ashlar or running bond. Another option is the stacked bond. Beyond these Running bond Stacked bond 16

14 Concrete Masonry it is over to the designer s imagination to consider the surface patterns and textures that can be achieved. Mario Botta, a Swiss architect, is renowned for combining blocks of various colour, texture, height and laying position to create wonderful patterns that become an integral part of his architecture. Note that the bracing values for partial filled concrete masonry in NZS 4229 are based on the running bond. Partially filling a stacked bond wall at 800 mm centres will leave every second block unbound which then becomes vulnerable under earthquake loading. It is therefore recommended to fill cells at 400 mm centres or closer when using stack bonded concrete masonry. Non-structural applications Concrete masonry is generally used in a structural capacity, for which it is ideally suited. It can also be used as an external veneer cladding in conjunction with other structural systems. The most common is timber framing but combining structural and veneer masonry with a cavity between will allow the designer to take full advantage of the external appearance, durability and thermal mass benefits. Method of insulation Appearance requirements and thermal mass objectives must be considered at the same time as the insulation strategies. concrete masonry veneer 15 series structural concrete masonry veneer tie insulation in cavity water proofing membrane The most common method of insulating a concrete masonry wall is to strap and line the internal face, fitting insulation between the strapping. An alternative approach is to fix insulation externally either in the form of rigid polystyrene sheet fixed in place with an external coating or by strapping and cladding with insulation between. weep hole 10 series concrete masonry veneer over 15 series structural wall. Cavity should be insulated. Proprietary self-insulating concrete block systems are available in New Zealand. Such systems allow both faces of the concrete masonry. This is achieved through the use of a biscuit of polystyrene fixed in a cavity near the exterior surface of the block. Concrete masonry built using the cavity method allows for effective use of insulation, thermal mass and the blockwork aesthetic. Insulation was often not included in the traditional cavity blockwork which gave these houses the reputation of being cold. While cavity construction allows insulation to be installed in the cavity, the detailing should ensure that the cavity will allow free drainage and that the type of insulation specified is capable of withstanding moisture. 17

15 residential concrete detailing and specification guide Waterproofing The considerations for choice of waterproofing system are set out in the General Section. It is most important to consider appropriate and effective waterproofing strategies for concrete masonry due to its porosity. Cracks that develop between the mortar and blocks are also areas of vulnerability that the waterproofing system must be capable of bridging. horizontal reinforcing steel vertical reinforcing steel sealant both faces Plan view of bond beam at control joint shrinkage central joint debonded bar vertical reinforcing Shrinkage control joint bond beam full height shrinkage control joint Unpainted and unsealed blockwork is an option in some circumstances such as when using veneer construction or in garages and uninhabited basements. It is important nevertheless to bear in mind the affect water can have on the masonry. Water can bring salts to the surface in the form of efflorescence, leaving an unsightly and unpredictable white pattern on the surface. 18

16 Concrete Masonry Shrinkage control joints Shrinkage control joints are necessary to ensure that shrinkage cracking occurs in a controlled manner and allows movement due to thermal changes. NZS 4229 specifies requirements for control joints. These should occur at approximately six metre centres and will affect the appearance of the project when the masonry is to be left exposed or painted. Applied finishes such as stucco plaster should also acknowledge the control joint to avoid consequential cracking. The designer should take charge of the control joint setout and carry out detailing as illustrated on the previous page to avoid any surprises on site. specification There are several New Zealand Standards that may be relevant to the written specification. These include the following: NZS 4229:1999 Concrete masonry buildings not requiring specific engineering design NZS 4230:1990 Code of practice for the design of masonry structures NZS 4210:1989 Code of practice for masonry construction: materials and workmanship AS/NZS 4548 Guide to long-life coatings for concrete and masonry NZS 4251:1974 Code of practice for solid plastering NZS 3604:1999 Non specific design Light timber frame buildings Materials All materials should be procured from a dependable source. Where appropriate, ensure that quality records are obtained and kept for easy retrieval, should they be required. Concrete blocks should be dry and remain so until they are used. Manufacture must comply with AS/NZS 4455 Excess moisture in any of the materials can reduce structural quality and require the blocks to have to dry longer before surface finishes can be applied. Steel reinforcing should be maintained free of dirt and organic material. Mortar mixing ratio (cement/sand/lime/water) to comply with NZS 4210 To provide a compressive strength of not less than 12.5 MPa. Concrete blocks stacked on pallets. 19

17 residential concrete detailing and specification guide 20 series Grout mixing ratio to comply with NZS To provide a compressive strength of not less that 17.5 MPa. Spread value mm Sand chloride levels should not exceed 0.04% by dry weight of sand Water one of the most important yet overlooked components of high quality concrete. Water must be clean and free from excess alkali, salt, silt and organic matter. Workmanship Concrete masonry work should ideally be carried out by qualified tradesmen. As a minimum, tradesmen should have experience in the required areas of construction. In some instances, such as detailed structural work, it is desirable to employ a Registered Mason. 15 series All concrete masonry work should be carried out under adequate supervision. Grout all cells that 1. contain reinforcing 2. are required to be filled as part of the design requirements Grouting should follow the procedures set out in NZS Form construction joints in accordance with NZS 4210 between grout pours and between the blockwork and any hardened concrete. The block layer must coordinate his work with the work of other trades. Coordination should take place well in advance of the work being done. The block layer must build in all elements including fixings, bolts, ties and any service requirements as called for, and/or necessary for the completion of the job. Once concrete masonry work is complete all block work must be cleaned. 10 series A selection of concrete masonry profiles that are available. Consult with manufacturers to determine the full range. 20

18 Concrete Masonry construction Planning the job One of the most important activities when building in concrete masonry is planning the project. The economy of concrete masonry block work can only be maximised with proper planning. Consider the module. Try to minimise the number of cut units and to maximise the sizes of any units to be cut. Doing so will also serve to keep costs to a minimum. Check with the designer who may have specified the placement of any cut units. Plan the sequence of activities carefully. This is especially important with respect to services that will occur in masonry walls. Setting out Reinforcing steel must be set out at foundation levels to fall within the planned location of cells. Normally the concrete masonry requires a vertical steel setout of 800 mm centre to centre spacing. Note that foundation stirrups typically occur at 600 mm centres meaning that only one in every four stirrups can be extended as vertical steel. Setting out of foundations to suit the specific requirements of the design is also critical. These include allowing for any specified overhangs of concrete block or veneer allowing for set downs or insets at door openings. Builders should take extra care when setting out services that will be concealed in masonry walls. This requires full coordination between trades such as plumbers or electricians and the reinforcing steel trade. Weather conditions Wet weather can cause build up of water in the blocks, as they are relatively porous. Excess water can reduce the strength of grout. This is particularly of concern where water is retained at the bottom of, or between lifts of, grouted cells. Rain onto fresh mortar can erode its surface, affecting the appearance and possibly the structural strength of the mortar joints. Cold conditions will not allow the mortar or grout to set properly. Concrete masonry and grout should not be placed in temperatures less than 4 C. Hot weather conditions are generally not a problem for concrete masonry in New Zealand. However, prolonged dry conditions may warrant attention when laying or grouting the masonry. Overly dry blocks will draw moisture out of the grout or mortar too quickly thereby affecting the bond with the blocks. It is therefore recommended that the blocks be wet lightly on those surfaces which will be against the mortar or grout. It is necessary to coordinate reinforcing placement with block setout. Provided the blocks are not too dry the curing of the mortar and grout does not require special care. If strong hot winds or direct sunlight in the middle of the summer are anticipated it would be prudent to ensure the mortar and block surfaces are kept moist for the first three to four days after being placed. Protection Builders should take care to protect finished concrete masonry from damage which could arise through the building process. This is particularly important with blockwork and veneer that has been designed to be left exposed. While in most cases it will be impractical to erect full protection for the masonry it should be possible to anticipate work that will create risks to the completed walls. Plywood sheets serve as an excellent form of protection. Kew House by Melling Morse Architects 21

19 residential concrete detailing and specification guide Roofing on building paper on wire netting Fascia Continuous timber plate on DPC Cast in bolt fixings External waterproofing system WALL TO ROOF External waterproofing system acrylic plaster & paint acrylic paint system sand/cement plaster system & paint sealer Bond beam at floor level INTERMEDIATE FLOOR Timber trusses Ceiling lining on battens Bond beam in accordance with NZS series conc. masonry Insulation MDF skirting Particle board flooring Bolt connection to bond beam per NZS 4229 Joist hanger Continuous boundary joist on DPC Internal linings on timber strapping Internally insulated wall section This wall section presents: single wythe 15 series concrete masonry building paper on the inside face of the masonry acting as a second line of defence against moisture penetration strapping and lining on the interior insulation between strapping concrete masonry foundation wall acting as permanent formwork for concrete slab on grade. These details separate the thermal mass of the concrete masonry from the interior space. It also allows the concrete masonry to be expressed as an architectural finish externally. 15 series conc. masonry vertical & horizontal reinforcing per NZS 4229 Waterproofing system extend min 50 below floor level Internal lining Insulation Building paper continuous Timber strapping 100 x 50 on DPC Reinforced concrete slab 150 MIN 100 MIN Paved G.L. Unpaved G.L. 15 series conc. masonry foundation wall. Starter bars at required spacing. DPC over 25mm sand blinding Compacted granular hardfill Reinforced concrete footing WALL TO FLOOR 22

20 Concrete Masonry Details Externally insulated wall section This wall section presents single wythe 15 series concrete masonry exterior insulation and waterproofing system concrete roof system concrete intermediate floor system reinforced concrete slab with thickened edge perimeter foundation. External insulation system Acrylic plaster waterproofing system Bond beam FALL Extend insulation and waterproofing over butyl with sealant bead Butyl as upstand dressed & sealed into chase in mortar joint Butyl on plywood on insulation on DPC Concete floor system This construction allows full advantage to be taken of the thermal mass in the house. The texture/finish of concrete masonry can be expressed internally. WALL TO ROOF Suspended ceiling system for services & lighting Proprietary external insulation system Acrylic plaster system Proprietary concrete floor system Bond beam INTERMEDIATE FLOOR Suspended ceiling system for services & lighting Proprietary external insulation system Acrylic plaster system Internal finishes paint system plaster system none Fix skirting & other elements by plug & screw on DPC Reinforced conc. slab 150 MIN 100 MIN Paved G.L. 50 MIN Unpaved G.L. Reinforced concrete perimeter edge beam Sand blinding on compacted hardfill DPC WALL TO FLOOR 23

21 residential concrete detailing and specification guide Roofing on building paper on wire netting Concrete masonry veneer Fascia Continuous 10mm gap for ventilation Masonry ties. Material to suit environment Ventilated cavity series conc. block veneer Timber trusses Ceiling lining on battens Concrete masonry veneer has been widely used in New Zealand house construction. The principle of a ventilated cavity can give a greater source of security to the homeowner and designer alike. As with all masonry, it is important to consider the modular height in setting out openings and heights of walls. This example shows the veneer stopping short of the soffit lining as a way of expressing the nature of the masonry on a veneer. This also stops the lining from meeting the masonry off the height module. WALL TO ROOF 75 max 40 min Ventilated cavity 10 series conc. block veneer Masonry ties in accordance with NZS 4229 Waterproofing on sloped plaster 75mm high weep 800 centres Building paper continuous 100mm insulation Internal lining Bottom plate bolted to foundation Skirting Reinforced conc. slab Note the requirements in NZS 4229 and NZS 3604 for the base material and protection for masonry ties in certain exposures. 150 MIN 100 MIN Paved G.L. 50 MIN Unpaved G.L. Sand blinding on compacted hardfill DPC WALL TO FLOOR 24

22 Concrete Masonry Details Externally insulated wall This system is designed to allow a traditional external appearance. Almost any external cladding can be chosen. Timber weatherboards are illustrated here. The internal finish should be applied directly to concrete masonry to allow the full advantage of thermal mass. Insulation External cladding fixed over building paper Timber strapping fixed to solid filled cells over DPC 150 MIN 100 MIN Paved G.L. 50 MIN Unpaved G.L. 15 series conc. masonry Cement/sand plaster or acrylic plaster internal finish Fix skirting & other elements by plug & screw on DPC Reinforced conc. slab Perimeter edge beam Sand blinding on compacted hardfill DPC WALL TO FLOOR Foundation crawl space This construction detail is ideally suited to a sloping site. The use of concrete masonry as a foundation footing can be both economical and time saving, particularly on sloping sites or those with limited access. External waterproofing and insulation system Bond beam Timber stringer on DPC 15 series conc. masonry Internal finish Timber skirting Particle board flooring M16 bolt to comply with NZS 4229 Sisalation or under floor insulation Openings in wall for ventilation to comply with NZS series reinforced conc. masonry footing on concrete bed RAISED GROUND FLOOR 25

23 residential concrete detailing and specification guide External waterproofing system 15 series lintel block Sealant over backing rod Timber frame on packing. Plug and screw to masonry Interior lining Insulation Building paper Timber strapping Architrave Timber reveal Glazing in timber window frame Timber window details Timber joinery is still the preference for many homeowners. Modern timber windows are well made and draft free. It is important to build these windows units in to ensure weathertightness. The details illustrated here indicate an appropriate method for doing so. HEAD DETAIL TImber reveal Galvanised metal flashing Architrave Extend waterproofing over plaster screed to falls and under sill generally External waterproofing system 15 series conc. masonry Interior lining Insulation Timber strapping Building paper SILL DETAIL 26

24 Concrete Masonry Details Aluminium window details Aluminium is the most common material for exterior door and window frames in residential construction. 20 series rebated lintel block Interior lining Building paper These details demonstrate the use of aluminium window frames in 20 series blockwork using rebated blocks. The rebated block allows a positive step for the frame to fit against. Insulation Timber strapping A When using an exterior membrane system be sure to extend it under the window frames prior to their installation. DPC should lap onto membrane and over building paper. DPC over waterproofing membrane and over building paper Build up waterproofing membrane and form drip Continuous sealant bead HEAD DETAIL Note the requirement by some window manufacturers to fit an angle (note A) in high wind areas to relieve the pressures on the sealant joint. Timber reveal Timber strapping A Continuous sealant bead Waterproofing system Interior lining Building paper Insulation 20 series rebated block. Reinforce per NZS 4229 JAMB DETAIL Timber reveal Position frame to allow drainage from within It is quite common to remove the projecting profile from the sill block to achieve a more flush appearance. Note that this may cause staining under windows as dirt that has settled on the sill gets washed down by rain. Timber strapping DPC over waterproofing membrane and over building paper Run waterproofing up under reveal Waterproofing system Remove projecting sill Interior lining Building paper Insulation 20 series rebated sill block. SILL DETAIL 27

25 residential concrete detailing and specification guide Acrylic interior plaster system. Neatly finish to timber frame DPC Timber packing Timber door head and bead External Insulating Finishing System (EIFS) 15 series lintel block Sealant Continuous head flashing Glazed timber door Timber door details The external ridgid insulation system allows the concrete masonry to be left exposed, or receive a thin finish as illustrated here. There may be thermal benefits to the home owner in adopting this strategy. The timber frame is supported on timber packing which is continuous and plastered over. The plaster system should be reinforced across this piece. Sealant is applied between the timber frame and the insulation system as a weather seal. HEAD DETAIL Acrylic interior plaster system. Neatly finished to timber frame DPC External Insulating Finishing System (EIFS) 15 series lintel block on end Timber packing Timber door jamb Timber bead Sealant Glazed timber door JAMB DETAIL Timber door sill Timber angle fillet EIFS beyond Glazed timber door Rebate slab for timber sill DPC Conc. slab Fairface concrete foundation beyond Form recess at openings SILL DETAIL 28

26 Concrete Masonry Details Aluminium door details These details show the aluminium door frame set in 15 series blockwork not using the rebated profile. This presents greater flexibility for the designer to position frame in depth of block. It may be preferable to use rebated block profiles in openings as this gives maximum weathering protection. Details show that the thermal mass is fully available to the interior space as the insulation is placed externally. Sand/cement plaster system Express control joint DPC Glazed hinged door in aluminium frame External Insulating Finishing System (EIFS) 15 series lintel block Sealant bead. Leave 50mm high gap at bottoms of jambs for water to escape HEAD DETAIL Sand/cement plaster system Express control joint External Insulating Finishing System (EIFS) 15 series block DPC Sealant bead. Leave 50mm high gap at bottoms of jambs for water to escape Glazed hinged door in aluminium frame The detail shows that the upstand leg from the sill frame across the threshold has been removed. This prevents it being damaged by being walked over. JAMB DETAIL Shaped timber threshold EIFS Aluminium door frame with weather strip on botttom edge Aluminium door sill frame Bring DPC over leading edge of slab Concrete slab Form recess at openings SILL DETAIL Fairface conc. foundation beyond Paving level 29

27 residential concrete detailing and specification guide Masonry ties in accordance with NZS 4229 Interior lining Insulation Masonry ties in accordance with NZS 4229 Interior lining Insulation Lap building paper over M.S. angle lintel Weep holes 125 x 125 x 8mm Hot dipped galvanised M.S. angle lintel fixed back to framing Sealant Timber Lintel per NZS 3604 Lap building paper over M.S. angle lintel Weep holes Galvanised metal head flashing. Timber Lintel per NZS 3604 Architrave Timber window frame Aluminium frame with timber reveal Veneer window details HEAD DETAIL HEAD DETAIL The position of window frames in a veneered wall is critical to ensure adequate closure of the gap while ensuring adequate fixing for the frame. Most aluminium window frames for residential use are delivered to the site with reveals fixed in the factory. Fixing through the reveal, as shown, will allow the frame to bridge the cavity. Timber window frames, on the other hand, may require framing support in the cavity, as shown. Units fabricated in the factory, before timber and aluminium may be able to span across the sill without fixings. Sealant between aluminium window frame and sill tile Sill tiles on plaster Galvanised metal sill flashing. Lap over sill tile Timber window sill Timber window frame Architrave Building paper Masonry ties in accordance with NZS 4229 Timber framing with insulation between Interior lining Sill tiles on plaster Masonry ties in accordance with NZS 4229 Continuous support for timber sill. Fix over building paper Interior lining 10 series masonry veneer 10 series masonry veneer Insulation SILL DETAIL SILL DETAIL 30

28 Concrete Masonry Details Roof details The use of sand/cement plaster allows a smooth uniform texture finish using a material similar in nature to concrete masonry. Care must be taken to: ensure adequate bond of sand/ cement plaster to concrete masonry follow control joints in masonry through sand/cement plaster A suitable paint finish will provide weatherproofing. Metal flashing Soffit Casement bead Bond beam Sand/cement plaster system (19mm textured surface) Timber purlins/rafters (cantilevered verge) Metal roofing on building paper Solid blocking Ceiling lining on battens Internal linings over 50mm timber strapping Insulation Building paper ROOF VERGE FALL Bond beam Proprietary external insulation system Acrylic plaster system Metal flashing dressed & sealed into chase in mortar joint Metal roofing to falls Furring to falls Bond beam Internal linings on ceiling joists/rafters PARAPET / METAL ROOF The use of an internal gutter suits many of the contemporary expressions of architectural design. Dimensions of such a gutter should be to suit the expected rainwater flow, but in no case should it be less than 600 mm for ease of cleaning. Provide secondary overflow capacity to ensure rainwater does not back up inside house. Bond beam Proprietary external insulation system Acrylic plaster system Gutter overflow. Opening size to match downpipe. Position below gutter freeboard height. FALL Butyl as upstand dressed & sealed into chase in mortar joint Butyl on plywood on 75x40 furring to falls Metal roofing to falls Furring to falls Bond beam 15 series conc. masonry Insulation Internal linings on ceiling joists/rafters PARAPET / METAL ROOF 31

29 residential concrete detailing and specification guide Suspended floor details 10 series concrete block veneer External waterproofing system acrylic plaster & paint acrylic paint system sand/cement plaster system & paint sealer 25 series bond beam 20 series concrete block Insulation Blocking Flooring Timber floor joist Ceiling on timber strapping Timber plate bolted to bond beam on DPC Internal linings on timber strapping on building paper A hybrid form of construction with concrete masonry ground floor structure and a lightweight structure above. The durability aspects and appearance of concrete masonry is continued with 10 series veneer over the timber framing. Suspended deck details are critical to get right particularly if they sit above interior spaces. When the concrete block module is seen from outside, it is critical to ensure the full module carries through floor level and that the detailing reflects this. BLOCK WALL / VENEER JUNCTION Services details As with most forms of concrete construction, it is critical to plan for appropriate services reticulation when detailing in concrete masonry. When using masonry veneer construction it is tempting to reticulate services in the cavity but this is specifically prohibited in NZS When using partial fill concrete masonry, dropping services from ceiling level in an empty cell can make the job much easier, particularly as a retrofit. It is advisable to cast sleeves into the bond beam to allow these services to be reticulated easily. Casting in additional sleeves to anticipate future alterations is also recommended. 32

30 Concrete Masonry Details 33

31 Insulating Concrete Formwork Insulating Concrete Formwork General Design Issues Specification Construction Details

32 Insulating Concrete Formwork Insulating concrete formwork (ICF) is a proprietary formwork system for concrete that is left in place to become part of the building. ICF systems have been available in New Zealand for the last 10 years and during that time have been increasingly used for both commercial and residential construction. ICF construction has been used for some 30 years in Europe, where concrete residential construction is quite common. A contemporary house built using insulated concrete formwork. Block systems are widely available in New Zealand. Plank and panel systems are available internationally but not currently in New Zealand. The forms are typically made of expanded polystyrene, a closed cell polymer. The reinforced concrete core provides all the structural capacity of the wall. The main advantages of these systems are: excellent insulation properties low levels of air infiltration blocks are easy to lay and fill relatively easy to run services concealed in polystyrene layer. This is true of both new construction and refitting work. long life expectancy 37

33 residential concrete detailing and specification guide design issues Although the principle of ICF construction is similar to that of concrete masonry, there are some important differences for the designer to consider. Module The modular height of systems available in New Zealand is typically 300 mm. As with concrete masonry, it will be more economical to work to the modular height for openings and wall heights. Most systems mechanically lock together along top and bottom edges. ICF systems are available in widths of 200, 250 and 300 mm. Unit widths correspond to different concrete thicknesses. The wider blocks offer increased structural capacity, little if any insulating increase and potentially reduce the interior floor space. The greater thickness will give greater reveal depth at openings which is often sought after by designers. ICF blocks are relatively long, in the order of 1000 to 1500 mm with many bridges between the faces. This allows the blocks to be easily cut to length without compromising the structural qualities. With block sizes like these, it is easy to see how these systems can be laid so quickly. Proprietary systems This part of the guide has been prepared with information obtained from the suppliers of ICF blocks in New Zealand. As much as possible, it has been the intention of the writers to present this information in a generic manner, thereby not favouring any one supplier. Typical ICF block format. Confirm the dimensions with the selected supplier. As soon as a particular system is adopted it is advisable that the designer confirm all details with the particular supplier. Applied finishes ICF systems comply with NZBC durability requirements, provided the blocks are appropriately finished or clad for protection from the effects of UV radiation and weather. Most ICF suppliers require that claddings or finishes are approved for use with their system. Modified acrylic plaster and paint systems, timber strapping with weatherboards, concrete masonry and stone veneers are examples of external claddings that ICF suppliers have recommended for use. Modified acrylic plasters, plasterboard or fibre cement sheet are typically used as internal linings. ICF suppliers will give guidance to the methods of fixing linings using adhesives and screws. 38

34 Insulating Concrete Formwork Detailing fixings One of the most important detailing considerations with ICF systems is that of fixings. This includes fixings for both structural and architectural elements. The formwork units, as they are made of polystyrene, offer limited fixing capacity. To make allowances for timber skirtings to be secured, the fixing of windows into openings and joinery fittings to be positioned, it is necessary to cast in timber fixing blocks. These are typically 150 mm long and are secured into the concrete core by pairs of nails that protrude off the back face. This apparently low technology detail is very effective, provided the necessary planning has allowed them to be in the right places. Structural elements such as concrete flooring systems can be accommodated and are installed after the concrete has been cast to the soffit level. The seating depth can vary between 50 and 75 mm. The method for fixing timber floor framing to ICF walls is to secure a stringer on fixings cast into the concrete core. specification It should be the objective of the specification writer to structure the documents in such a way as to encourage competitive pricing. Fortunately there are several suppliers of the forms in most parts of New Zealand. Once a system has been selected it is advisable to confirm all details and other design issues with the selected manufacturer. This includes wall thicknesses, building in details, steel reinforcing requirements and construction requirements. It is desirable to structure the ICF sub-contract on the basis of engineering design and supply. It may also be possible to include the erection of the system in that subcontract. Timber inserts facilitate fixing of door frames, skirtings and other joinery items. A Producer Statement: Design, or some other evidence of structural capacity should be required by the specification. This will assist the Territorial Authority in approving its use. Manufacturer s literature and guarantees should also be required by the specification. Standards referred to: NZS 3101: 1995 The design of concrete structures NZS 3104: 1991 Specification for concrete production high grade and special grade NZS 3109: 1997 Concrete construction NZS 3402: 1989 Steel bars for the reinforcement of concrete Materials There is at present no New Zealand Standard for the manufacture of ICF units. Accordingly the designer should reserve the right to approve the supplier. 39

35 residential concrete detailing and specification guide ICF Blocks should be made of fire retardant materials. In situations where fire resistance ratings are required. These must be specified as not all ICF blocks provide adequate fire resistance. Concrete infill to achieve a minimum compressive strength of 20 MPa. Maximum aggregate size to be 14 mm. Concrete slump should comply with the ICF manufacturer s requirements. A 100 mm slump is typical. Expansive additives must not be used in any circumstances as these can blow out the forms. Steel reinforcing to comply with NZS Workmanship Erection and filling of the system should be carried out either by the ICF supplier or by a firm approved by them. The installation should be carried out by persons with experience in this type of work. All necessary and appropriate equipment and construction techniques to be employed. Concrete floor systems can be easily accommodated in ICF construction. Diagram showing ICF components. The blocks are fitted together and propped in place before filling with concrete. Temporary wire ties may be necessary to prevent the blocks floating on the concrete fill. These should be installed every four courses. Allow to build in all fixings and services as detailed and required by various trades. Typically, such fixings are supplied by the relevant trade or by the builder, to ensure they are correct. The ICF trade must coordinate with all other trades. Allow to locate and form construction joints in accordance with NZS Before placing concrete, ensure all cells are clean and reinforcing is secured in place. Consolidate concrete with a max 25 mm diameter poker vibrator or by rodding. Vibration should ensure that all cells are filled with well compacted concrete. Extent and height of lifts to be in accordance with ICF manufacturer s recommendations. Significant construction tolerances for ICF are to be expected given the nature of the material. It is prudent to limit tolerances and to ensure subcontractors are aware of them so they can make appropriate allowances. Recommended limits are as follows: Deviation from plan location Deviation from vertical within a storey Relative displacement between load bearing walls in adjacent stories intended to be in vertical alignment Deviation from line to plan Any length up to 10 metres Any length over 10 metres Deviation from horizontal Any length up to 10 metres Any length over 10 metres 20 mm 10 mm per 3 m 5 mm 5 mm 10 mm 5 mm 10 mm 40

36 Insulating Concrete Formwork construction Planning the job Due to the speed with which ICF systems can be erected, it is important to plan well ahead. Follow the manufacturer s recommendations for the height of each lift. ICF blocks are easy to cut, allowing opportunities to deviate from the block module. It is important to consider, from a construction viewpoint, that the ICF walls have no structural capacity until the concrete core is cast. Therefore it is important to provide adequate propping and support for these elements until the concrete has achieved the appropriate structural strength. Setting out As with other systems covered in this guide, it is important to set out reinforcing to suit the ICF block width. This must be confirmed prior to casting of foundations. The ICF forms can be used for internal and external walls. 41

37 residential concrete detailing and specification guide Weather conditions Due to its insulating qualities, in theory concrete can be placed in colder conditions than it can into other types of formwork. However, this is rarely a factor in New Zealand conditions. The forms themselves can be placed in most weather conditions, although the unfilled forms are susceptible to displacement in high winds. Concrete can be placed in the forms when it is raining provided measures are taken to remove water in the bottom of the forms, which if left will mix with the concrete thereby reducing its strength. Curing and drying ICF systems enhance concrete curing by slowing water evaporation. This effect can increase concrete strengths. Obtain, and comply with the ICF and coating manufacturer s recommendations for drying times prior to the application of surface finishes. Protection ICF is vulnerable to mechanical damage particularly before claddings are applied. Protection, such as plywood sheeting, should be considered in areas of high risk during construction. It is important to prop ICF units appropriately until concrete has set. At exposed corners and edges PVC protection is recommended as part of the cladding system. Prolonged exposure to sunlight can cause surface deterioration of the polystyrene. If the surface becomes scaly after a period of exposure, this scaliness must be removed prior to the application of surface finishes. The minor deterioration that may occur will have no effect on the structure of the wall. Some reduction of the insulation properties may occur, depending on the depth of deterioration. Stone and other veneers can be used to give the house a traditional appearance. 42

38 Insulating Concrete Formwork Details Wall section These details indicate how the ICF construction system can be combined with various concrete floor systems. The roof details indicate a concrete floor slab system with topping formed to falls. With all parapet conditions it is important to make allowance for overflow in case primary drain becomes blocked. Reinforce corners of plaster systems External plaster finish Reinforcing mesh Construction joint FALL Fix Butyl into chase cut into wall. fix 90 PVC angle cap to Butyl edge and seal in place. Plaster down onto PVC angle Butyl on Plywood base Insulation over DPM Concrete topping to falls Insulation is shown on top of roof slab to allow thermal mass to help moderate indoor temperatures and to prevent condensation that may develop in certain conditions. Suspended floor detail indicates precast beam and infill system. ICF block system Reinforcing CONCRETE ROOF Concrete slab. Prop in place until conc. is cured Metal frame suspended ceiling A suspended ceiling can be included to conceal services and the soffit of the flooring system. With appropriate planning and good workmanship, it is possible to leave these surfaces exposed, thereby saving the cost of the ceiling, enjoying greater floor/ceiling heights and the thermal mass benefits of the concrete. ICF can be used as permanent formwork for foundations. External plaster finish Reinforcing mesh Rough broomed surface to ensure good key Construction joint ICF block system Internal finish Skirting fixed to intermittent timber block cast into conc. Reinforced conc. topping TImber formwork Conc. beam & timber infill floor system Cut hole in block at each conc. beam Reinforcing Metal frame suspended ceiling Internal finish CONCRETE FLOOR External finish ICF block system Internal finish Reinforced conc. slab PVC starter strip, forming a drip edge Paved G.L. Unpaved G.L. Reinforced concrete footing WALL / SLAB DPC Sand blinding Compacted granular hardfill 43

39 residential concrete detailing and specification guide Roofing Building paper & timber purlin Timber truss Connection plate between top plate and truss Top plate 750max ctrs with cast in bolts Wall section The details on this page indicate a traditional sloping roof with overhang. Planning is required to cast in appropriate fixings for structural and architectural elements, as ICF will not support or transfer any loads. Gutter Fascia board Soffit lining Timber stringer, 750max ctrs. with cast in bolt ROOF OVERHANG External finish Malthoid strip between timber and concrete or use H3 treated timber ICF block system TIMBER FLOOR Ceiling battens Insulation DPC Internal lining ICF block wall Skirting fixed to intermittent timber block cast into conc. Flooring Timber joists Joist hanger Continuous slot cut in block wall for stringer ICF block system The suspended timber floor must be securely anchored to the wall to transfer vertical and lateral loads. This should also coincide with a horizontal bond beam. As the intermediate floor acts as a diaphragm in this case, only one horizontal bar is required in the bond beam. The timber frame floor/ceiling assembly allows electrical services to be easily reticulated, but acoustic performance is somewhat compromised in comparison with a concrete system. The concrete slab on grade forms a perfect base for the insulated concrete formwork system. It is important to coordinate reinforcing steel starter bars and fixings for skirtings and the like. External plaster finish. Extend to ground level PVC channel Internal finish Skirting Reinforced concrete slab Paved G.L. Unpaved G.L. DPC Extend insulation down to bottom of foundation Compacted sand blinding Granular hardfill WALL / SLAB 44

40 Insulating Concrete Formwork Details Aluminium window details The key to fitting doors and windows into openings in ICF partitions is to plan for, and cast in, appropriate fixings. These fixings must be H3 treated or higher, as they are generally in full contact with concrete. These fixings are intermittent, about 150 mm long at 450 mm centre spacings. The nails on back help anchor the timber to the concrete. These details also make use of aluminium flashings and sealant to ensure a weathertight opening. The flashings must be compatible with the exterior finishing systems and fixed in a manner that will not cause the acrylic plaster system to break down. ICF block system External plaster finish. Corner strip Form drip edge PVC flashing Sealant bead HEAD DETAIL Aluminium window section Intermittent H3 timber blocks. Fix galv. nails skew nailed to timber & cast in concrete infill. Internal finish Timber reveals Aluminium window section Timber reveals PVC flashing Sealant Corner strip Internal finish External plaster finish. ICF block system Timber packer Intermittent H3 timber blocks. Fix galv. nails skew nailed to timber & cast in concrete infill. JAMB DETAIL Timber reveals Aluminium flashing External plaster finish Timber plate Corner reinforcing ICF block system Internal finish Intermittent H3 timber blocks. Fix galv. nails skew nailed to timber & cast in concrete infill. SILL DETAIL 45

41 residential concrete detailing and specification guide ICF block system Corner strip Form drip edge Sealant & backing rod PVC flashing Modified acrylic plaster. Return at reveal Corner protection Sealant Timber window frame Timber window details These details, like those on the facing page, rely on the fixing capacity of cast in timber blocks. The interior finishes here are shown to return in to the window frame as a reveal. This is effective in creating a massive look to the walls. External corners of ICF are vulnerable and must be protected with PVC corners integrated with the plaster system. HEAD DETAIL Sealant & backing rod Modified acrylic plaster finish Corner strip ICF block system JAMB DETAIL Timber window frame Sealant Corner protection Intermittent timber blocks. Fix galv. nails skew nailed to timber & cast in concrete infill. Internal finish. Return to reveal Timber sill Fit timber sill over flashing & timber packing Sill flashing External finish. Carry under flashing. Timber plate Continuous H3 timber, shaped to fall ICF block system Internal finish SILL DETAIL 46

42 Insulating Concrete Formwork Details Aluminium door details It is good practice to step back the concrete slab edge at door openings to avoid an awkward and vulnerable sill outside the door. This requires particular coordination between the concrete placer, ICF contractor and metal door and window supplier. It is also advisable to allow for a threshold that is robust and easy to pass over, this may require the aluminium frame profiles to be modified. ICF block system Corner strip Form drip edge Front sealant after planter Back sealant before planter Lining Intermittent H3 timber blocks. Fix galv. nails skew nailed to timber & cast in concrete infill. Aluminium door frame with timber reveals HEAD DETAIL Aluminium subframe Front sealant after planter Back sealant before planter Corner strip ICF block system External plaster finish Intermittent H3 timber blocks. Fix galv. nails skew nailed to timber & cast in concrete. JAMB DETAIL Aluminium door frame with timber reveals Aluminium door frame over sill flashing Step back concrete slab edge to suit reveal Paving level Shaped Timber on DPC Reinforced conc. slab SILL DETAIL 47

43 residential concrete detailing and specification guide Exterior plaster finished Corner strip Slope to form drip edge Sealant & backing rod PVC flashing. Plug & screw into conc. ICF block system Interior finish. Return to reveal Intermittent timber blocking. Fix galv. nails skew nailed to timber and cast in concrete infill. Sealant Timber door & frame Timber door details The timber frame is set in the centre of the massive ICF wall. This massiveness is accentuated by returning the interior and exterior wall finishes into the reveal. Careful coordination of the rebate for the door sill will allow a near seamless transition from inside to out. All timber must be separated from concrete by DPC. HEAD DETAIL Sealant & backing rod Aluminium flashing Timber door & frame Sealant Interior finish. Return to reveal Corner strip Exterior finished plaster ICF block system Intermittent timber blocking. Fix galv. nails skew nailed to timber and cast in concrete infill. JAMB DETAIL Timber door & sill. Recess sill into slab. Butyl rubber sill flashing Flooring Reinforced conc. slab ICF block system. EPS stripped. Plaster smooth Paving level SILL DETAIL 48

44 Insulating Concrete Formwork Details Hybrid construction detail It may be desirable to combine structural systems as this detail indicates. Interior lining Timber framing The important coordination exercise here is to ensure that the timber framing is set out to allow the exterior finishes to continue flush from the ICF to the Exterior Insulation Finishing System. Note that the acoustic separation provided by this timber framed floor is minimal. Refer to the manufacturer s literature for guidance on details that can improve acoustic performance. Exterior insulation system Continuous top plate 750max ctrs with cast in bolts Exterior finish system ICF block system DPC Internal plaster finish HYBRID CONSTRUCTION DETAIL High thermal mass detail To overcome the thermal mass being separated from the internal space, it is possible to remove the inner skin of ICF to reveal the concrete cores which can then be plastered smooth to a finish that is tough and durable. Exterior finish system Extend plaster finish to footing ICF block system. Interior EPS removed Internal plaster finish Reinforced conc. slab Paved G.L. Unpaved G.L. DPC Reinforced concrete footing Sand blinding Granular hardfill HIGH THERMAL MASS DETAIL 49

45 residential concrete detailing and specification guide Cavity Concrete masonry veneer Concrete masonry veneer Waterproofing membrane Veneer ties extending to vertical reinforcing Weep 800 crs Paved G.L. Unpaved G.L. Strip outer face of ICF ICF block system Internal finish Skirting & lining on intermittent fixing blocks Reinforced conc. slab DPC Sand blinding Granular hardfill It is possible to combine the excellent durability and appearance of concrete masonry with the insulating qualities of ICF. Waterproofing of the ICF outer face (in the cavity) is usually by a painted on system such as bituminous paint. The veneer (10 series) must be secured to the structure by way of ties that are embedded in the concrete cores. This will require special attention to coordination of ties with anticipated joints. FOUNDATION Cavity Concrete masonry veneer Veneer ties 2 coats waterproofing membrane ICF Block system Lining Timber blocks. Fix galv. nails skew nailed to timber & cast in concrete infill. MS angle Fibre cement sheet Aluminium flashing Aluminium Window section with Timber Reveals HEAD Aluminium window joinery Tile sloping sill on 9mm fibre cement board on shaped timber 2 coats waterproofing membrane Concrete masonry veneer Veneer ties extending to vertical reinforcing Timber reveals Timber plate Timber block ICF block system Internal fininsh SILL 50

46 Insulating Concrete Formwork Details Roof details Providing adequate and appropriate fixings for additional structural or architectural elements is critical. All three of these details show typical fixings that must be allowed for. Flashing Fascia Soffit DPC ICF block system Roofing Building paper Timber rafter Insulation Ceiling batten Top plate embedded in ICF block. 12mm Galv. bolt cast in Conc. Internal finish OVERHANGING VERGE Slope top of blocks in towards gutter. External finish Apply sealant in chase then insert flashing. Flashing Roofing on purlins ICF block system Steel reinforcing PARAPET Ceiling batten Rafter fixed to block with galv. bolt. DPC Slope top of blocks in towards gutter. Ensure adequate provision is made for overflow should the primary system block up. Internal gutters should be wide to allow ease of service and deep enough to accommodate the expected runoff. External finish Fix Butynol into chase in block, fix 90 PVC angle cap to Butynol edge and seal in place. Finish Plaster down onto PVC angle Fix Butynol on Plywood base to form gutter as shown Purlins on edge Joist hanger ICF block system Reinforcing Plywood base fixed to timber framing PARAPET Stringer fixed to block with galv. bolt. 51

47 residential concrete detailing and specification guide FALL Terrace details External finish Fix waterproofing membrane into chase cut into wall. Fix 90 PVC angle cap to Membrane edge and seal in place. Plaster down onto PVC angle Timber decking Waterproofing membrane on Conc. roof Raised terraces over living space are now very popular. Detailing of terraces presents a number of challenges in allowing ease of transition inside vs. outside preventing water ingress at door openings preventing water ingress at walls, especially at construction joint between slab and upstand Construction joint Construction joint ICF block system Reinforcing Precast concrete slab Insulating plasterboard lining Linings Timber Decking Waterproofing Membrane carried up under door joinery. Aluminium Door section Reinforced Conc. topping A step in raised concrete floor levels requires a special coordination effort to ensure continuity of structure and support of the concrete flooring systems. ICF block system Reinforcing Precast concrete slab Insulation Linings 52

48 Insulating Concrete Formwork Details Services ICF present the easiest way of reticulating services of any concrete structural system. Services up to 40 mm, depending on the thickness of the polystyrene face, can be accommodated by cutting away a chase. Generally these services must be securely fixed to the concrete core by way of lamps and tappets. The chases must then be covered over by the finishing process. Plasterboard is generally able to span across the gaps but care must be taken to not place a sheet joint on the chase. Plaster systems will require a bandage. The supplier should be contacted for details. Services can also pass through the walls but positions and sizes must be approved by the manufacturer. 53

49 Precast Concrete Precast Concrete General Design Specification Construction Details

50 Precast Concrete The development of concrete precasting techniques in this country has allowed reinforced concrete to compete favourably with other forms of construction. Curiously it has not made a serious entry into the residential construction market until the past 10 years. This later period has coincided with the development of proprietary self insulating precast systems. Details of such systems are presented in this section but there is also plenty of scope for applied insulation systems. Concrete precast methods were pioneered in the US early in the 20th century. The New Zealand industry is well developed and generally acknowledged as a world leader. There are good supplies of the raw materials and technology in most parts of the country. Precasting, whether done in factory conditions or on site, offers the opportunity to control the quality to a high standard. Advantages of precast concrete construction systems include the following: quality control the quality is better able to be controlled by casting multiple units in the same mould, by casting walls flat rather than standing upright and through the ability to better control environmental conditions. lower costs for the reasons noted above. finishing options inherent in solid concrete construction interesting shape and texture possibilities speed of construction with off site production the panels and other precast elements can be made while the site is being prepared. It is possible to set up a house in two days with an experienced crew. The Pascal House in Auckland by Cook, Hitchcock & Sargisson. 57

51 residential concrete detailing and specification guide Precast flooring systems are ideal for use in a concrete home. A number of different flooring systems are currently available in New Zealand. These proprietary systems have been developed for commercial buildings, but are also suitable for the span and loading demands that can be anticipated in residential construction. Suppliers generally offer design services which can be incorporated into the overall structural design philosophy. These flooring systems can be categorised as follows: flat slab hollow core slab rib and infill steel tray permanent formwork The systems all offer excellent stiffness, durability, acoustic and thermal performance, they can be planned to include penetrations and openings and are cost competitive with timber flooring systems. They are also not prone to annoying squeaks that can occur with timber floor systems. Precast concrete systems include floor units in addition to walls. design As with in-situ concrete (refer to In-situ section), there are choices to be made with respect to the following: Surface Texture There are many opportunities with precast concrete to create interesting surface textures. Finishing techniques for the formed (underside) face are described in the surface finishes section. The screeded face (topface) generally becomes the second side or back. Texture options include: exposed aggregate acid etched ground and polished board formed Colour Concrete used in precast work can be coloured. This can be achieved with colour throughout the mix, or alternatively, it is possible to place coloured concrete on the exposed face with standard concrete behind. Combining surface finishes can help break down the scale of a building. Panel or unit format The size and layout of individual panels is essentially limitless. However, there are some practical limitations. Typical parameters that may dictate panel size are: the area available for casting (when casting on site). This may be an area of a floor slab or a separate temporary casting slab. efficient repetitive use of special moulds site access capacity of lifting equipment or transport the positioning of panel joints relative to openings. 58

52 Precast Concrete there are also aesthetic considerations to be made. Panel size will dictate joint set out and affect scale, texture and surface articulation of the house design. The designer must also take into account panel thickness. There are structural aspects to consider for both transport and permanent positions. The designer may be particularly interested in panel thickness when considering opening reveal depths and thermal mass benefits. Commonly panel thickness varies between 100 mm and 150 mm. Sandwich construction allows concrete panel to be left exposed inside and out. Jointing Details The width and depth of joints between panels, as well as the profile of the panel edges, must be considered by the designer. Examples of weatherproofing details are shown to the left, the most commonly used detail in the face-sealed joint. Other considerations include how connections are made between panels, to the floor, and to any other structural or non-structural elements. These deliberations will most certainly include the structural designer for the project. Options include expressing plates and bolts, countersinking and plastering over welded plates or to conceal entirely by using pressure grouted tubes. Typical panel jointing details. Edge details Individual panel edges, especially when exposed to view, are a design opportunity. These considerations are best made in the context of the joint design but should also look at corners, openings, top edges and junctions to other materials. Panel edges are vulnerable, especially during placement of panels. It is very difficult to successfully cast a crisp 90 corner on any concrete panel, it is therefore advisable to chamfer the corners. 59

53 residential concrete detailing and specification guide Insulation and weatherproofing Although more waterproof than other forms of concrete, such as masonry, precast concrete is still permeable to water and requires waterproofing. Waterproofing can be achieved by application of acrylic paint systems, which can be applied direct or as part of a plaster finish system. Veneer cladding systems can also provide the required waterproofing. Insulation can be placed on the exterior, interior or between skins of concrete. This latter strategy has given rise to a number of specialist panel systems which allow all the positive aspects of concrete to be realised without compromise. These systems make use of a polystyrene sheet, between an outer skin or veneer of concrete, and an inner skin which typically acts as the structure. The two faces are held together by thermally non-conductive ties which are cast into each wythe. specification Designers have a choice to make between proprietary sandwich construction and the traditional forms of precast. If the choice is to use a proprietary system, the specification should be generic to allow a range of proprietory systems to be evaluated. A proprietary system supplier may be required to provide Producer Statements, guarantees and construction recommendations. It may be prudent to require the contractor or precaster to produce sample panels for evaluation of such aspects as surface finishes. Work should not be allowed to proceed without the designer s approval of these samples. The Standards which apply to precast concrete construction are as follows: NZS 3101:1995 Concrete Structures Standard The design of concrete structures NZS 3104:1991 Specification for concrete production High grade and special grade NZS 3109:1997 Concrete construction NZS 3112 Methods of test for concrete NZS 3113:1979 Specification for chemical admixtures for concrete NZS 3114:1987 Specification for concrete surface finishes NZS 3402:1989 Steel bars for the reinforcement of concrete NZS 3121:1986 Specifications for water and aggregate for concrete NZS 3421:1975 Specification for hard drawn mild steel wire for concrete reinforcement Sandwich construction detail. Joining plate can be left exposed as a design feature. 60

54 Precast Concrete NZS 3422:1975 Specification for welded fabric of drawn steel wire for concrete reinforcement Comprehensive lifting systems are available. Materials All materials should be procured from a dependable source. Where appropriate, the builder must ensure that quality records are kept for all precast concrete work. These records must be easily retrievable should they be required. Formwork Formwork requirements are detailed in NZS Reinforcing steel To comply with NZS 3402, NZS Concrete Readymix concrete to the specified compressive strength and to the requirements of NZS Special aggregates For special finishes specify the aggregate type, colour, size, range and depth of exposure. All aggregate to comply with NZS Lifting inserts Proprietary lifting devices are preferable. It is important to match the lifting inserts with the apparatus that will be used for lifting and the processes that will be adopted for casting and lifting. Steel connection plates It is recommended to galvanise any mild steel fixings that will be exposed to weather. Workmanship Construct formwork in the configuration necessary to produce the required set out and detail of panels. Pay particular care to edge details. The construction and casting of panels should be carried out by tradesmen experienced in precast concrete construction. Place and cure concrete to produce the specified finishes and tolerances. Curing should be carried out for at least 7 days. Surface finishes shall be as specified by the designer and as defined in NZS Allow to cast in all items required for fixings or services. This requires coordination between the trades before the panels are designed and cast. The installation should be carried out by contractors experienced in precast construction. All necessary components such as gaskets, sealants and flashings should be supplied and fitted. Rigging and lifting must be done using the lifting points specified. Take care not to knock or drag panels along the ground. Panels must be secured in place before any temporary supports are removed. At all times during the construction process, but especially the lifting of panels, the health and safety of all workers and the public must be ensured. Tolerances for precast panels (measured as defined in NZS 3109) shall be: Panel dimension (metres) Up to Over 6 Width (mm) +0, -5 +0, , -12 Height (mm) ±5 ±10 ±10 Planeness (mm) ±5 ±5 ±5 Squareness (mm) ±5 ±15 ±15 Edge straightness (mm) ±5 ±7 ±10 Thickness (mm) ±10 ±10 ±10 Ensure existing surfaces all comply with the tolerance requirements. Panel erection underway. 61

55 residential concrete detailing and specification guide Concrete panel will be set over the reinforcing steel. construction Planning the sequence of activities, especially if the panels are to be cast on site, can save substantial time and frustration. Good planning will allow the panels to be cast earlier and will allow work to carry on around the panels once they are cast. With on-site casting planning the site is critical. The location to be used for casting must be of appropriate size and in a location that can continue to be accessed as the panels are erected. Access must be available for materials and for the crane. The sequence of casting panels must be logical if they are to be cast one on top of the other, last on is first off. Normally panels are erected sequentially from one corner. Setting out If the panels are to sit on the ground floor slab, it is critical to confirm constructed dimensions of the slab, prior to constructing the panels. It is also critical to coordinate and check positions of starter bars and grout tubes. Weather conditions The wall panels must not be cast in rain or cold conditions below 4 C. Particularly in hot, windy weather it is important to prevent excessive surface evaporation which can lead to plastic cracking. A common method of providing protection is to use anti-evaporative spray. Precast panels are particularly prone to this potential problem, due to their large surface area. Once the panels are cast and ready for erection, the construction process need not be affected by the weather. Panel erection & finishing Preparation for the second concrete skin in sandwich type wall panel. After factory produced panels are cast and adequately cured, they must be transported to site. Suppliers of these panels have delivery and erection systems in place which should be of benefit to the builder. The tilt-up panel erection process begins with the separation of panels. The performance of the bond breaker during this operation is critical. The bond breaker must: permit clean complete separation of panels not discolour the panel surface minimise suction at time of separation be compatible with the curing components that may be used. Note that release agents used to facilitate the stripping of formwork in in-situ construction are not suitable as bond breakers. The crane is critical to the erection process. It must be rated to achieve the panel lift at the maximum anticipated working radius. The lifting capacity of a crane reduces considerably with larger working radii. The crane must be able to access the site 62

56 Precast Concrete and be adequately supported in each position it will be set. The rigging, lifting point and support design for movement of panels is critical. The strategies must be discussed and agreed between the appropriate parties. The builders concern will be access for fixing operations and ease of panel handling, the engineer will be concerned that the support points are structurally appropriate and the designer will want to make sure the lifting inserts can be hidden from view after the panels are in place. One of three strategies can be adopted: Top edge lifted panels will hang vertical but this is not economical for units over 3-4 metres in height. Face supported panels will hang slightly off vertical, however, they can easily be plumbed with adjustable props once in position. Face lift points may require plastering or alternatively they can be deliberately featured. The use of lifting points on the face and top edge is sometimes used but requires a crane with two separate ropes. The crane must move the panels smoothly into position, avoiding shock loading which can induce cracking in the unit. Panels must be supported entirely by the crane until they have been secured into final position and propped. It is important to select propping positions that will not interfere with other construction activities. Planning for crane access is important. Surface finishes While the design and specification of surface finishes falls within the scope of the designer, it is the builder or precaster who must ensure the specified finish is achieved. The surface finish treatment must be coordinated with the lifting and casting strategy. The most common face to treat with an integral finish is the face cast down. As lifting points will be on the back face, this allows the bottom face to be completely monolithic. The table indicates common methods for achieving surface textures. 63

57 residential concrete detailing and specification guide The exposed aggregate finish warrants special consideration. Chemical retarders are often used to allow the surface to be etched. The cement matrix can then be removed with a water blaster once the panel has been lifted. The use of chemically impregnated paper can simplify this process but also gives the designer additional scope for achieving patterns in the surface. Architects Herzog and de Muron have experimented with retarder impregnated paper to achieve stunning concrete effects. Sandblasting is also an option but has largely fallen out of favour with the introduction of the processes described earlier. Cutaway of door opening in a precast sandwich type wall. Types of Finish Rebates, grooves and patterns Plain, smooth surfaces Exposed Aggregate Fine Textures Coarse Textures Face-up (single casting) Hammer form into top surface (Position and depth difficult to control) Finish panel with bull float and trowel (Common paving technique) Water washed (Special aggregates and patterns difficult to control) Broomed, Combed, Imprinted, Rolled Face-down (single or stack casting) Fix form to base slab (Position and depth easy to maintain) Finish off floor or casting pad (Reproduces all imperfections of that surface) Sand embedment (Special aggregates and patterns easy to achieve, independent of concrete mix) Timberforms, Formliners Timber forms, Profiled steel sheeting, Polythene over stones, Formliners A three level project planned using off site precast concrete panels. 64

58 Precast Concrete Details External insulation on tilt panel Roofing on building paper on wire netting 100mm insulation The details illustrated here are of the exterior envelope consisting of a concrete slab on grade, site precast wall panels and timber framed intermediate floor and roof. External weatherproofing and insulation is provided by one of many rigid polystyrene systems with acrylic plaster/paint. In this case the panels, designed to be seen from the inside should be cast with this face down. Lifting inserts will be covered by rigid insulation. If skirting is required, allowance should be made to cast-in fixing blocks. Vertical panel joints will be seen internally and should be detailed accordingly. The panel to slab connection is made after the panels are erected. This is very efficient structurally and economically but requires special consideration if the floor slab is to be exposed. Rigid insulation panels External waterproofing system WALL TO ROOF External waterproofing system Rigid insulation panels INTERMEDIATE FLOOR Plywood ceiling panels Roof 1200 cts Timber plate on DPC with cast-in anchor Structural conc. panel Skirting on cast-in fixings Flooring Bolt connection Joist hanger Continuous stringer on DPC Seal concrete. Exposed finish Rigid insulation panels Waterproofing system extend min. 50mm below floor level Reinforced conc. slab Insitu concrete between slab & wall panels 150 MIN 100 MIN PAVED 50 MIN UNPAVED Site precast panel. (Tilt slab) Reinforced concrete footing Sand blinding on compacted hardfill WALL TO FLOOR Extend DPC under footing 65

59 residential concrete detailing and specification guide Continuous aluminium angle screw fixed over butyl & sealant Non structural conc. veneer Insulation WALL TO ROOF Non structural conc. veneer 18mm construction ply screw & adhesive fixed on DPC Butyl roofing membrane extend up & over parapet Timber plate on DPC secured by bolt 18mm Plywood Insulation between framing Joist hanger Ceiling lining Structural conc. panel Structural conc. panel Preformed duct structural joint Skirting fixed to cast-in timber fixing blocks Sandwich panel construction These details indicate the use of polystyrene insulation between concrete panels in wall section. Also shown is a horizontal joint detail, which must be carefully considered in the elevation design. Concrete flooring system can be designed to lock into supporting walls, as shown, or supported on a surface mounted steel angle, as shown on the following page. Grouted duct connections allow shorter panels than the detail shown previously, and for the floor slab to be cast in one operation. This makes it easier to achieve a uniform finish, which can be an advantage if it is intended to leave the slab exposed. Sealant joint with weep 900 ctrs Insitu conc. topping 50 MIN Insulation 75 seating Concrete flooring units Structural conc. panel INTERMEDIATE FLOOR Insulation Sealant joint with weep 900 ctrs Structural conc. panel Preformed duct filled with expansive grout Skirting fixed to cast-in timber fixing blocks 150 MIN 100 MIN Paved G.L. Unpaved G.L. Sand blinding Compacted hardfill Reinforced conc. slab on grade WALL TO FLOOR 66

60 Precast Concrete Details Sandwich panel construction This wall section indicates precast panels (site or factory) which extend from floor slab to parapet in one section. This eliminates the need for a horizontal joint between panels which is often not architecturally desirable. Veneer panel is shown to thicken near the top, at the expense of the structural panel thickness. This allows veneer to cantilever as parapet. Insulation thickness is maintained. Concrete parapet Rigid insulation External waterproofing system Rigid insulation Non structural conc. veneer Structural concrete panel WALL TO ROOF Continuous aluminium flat screw fixed over butyl Butyl membrane on 18mm construction ply Vapour barrier Concrete flooring units Suspended plasterboard ceiling system Internal finishes options plasterboard paint system only acrylic plaster system unfinished Non structural conc. veneer Structural concrete panel Skirting fixed to spaced timber blocks Steel reinforcing connector cast-in Rigid insulation Concrete flooring units INTERMEDIATE FLOOR Non structural conc. veneer Rigid insulation Panels set on packing. Apply sealant with 900 crs Structural conc. panel Skirting adhesive fixed Mortar Reinforced concrete slab Floor covering 150 MIN UNPAVED LEVEL DPC WALL TO FLOOR 67

61 residential concrete detailing and specification guide Jointing details Fibre composite/ non metalic connector Rigid insulation 10mm - 20mm joint 6mm arris all edges Backing rod & sealant Weep 900 crs Hole to expel grout (when cavity full) Grouted duct Hole to feed grout Backing rod & sealant Donut seal Structural panel Threaded connector Steel reinforcing The architectural expression of joints between panels requires consideration. Design decisions include; how the edges are shaped, the width of joints, integration with other details, and proportions that result from their set out. The structural fixings can be expressed as steel plates or hidden from view. Flexible silicon based sealants are typically used to weatherproof the joints. It is important that these sealants are checked and maintained periodically. HORIZONTAL JOINT Non structural conc. veneer Rigid insulation 10mm - 20mm joint 6mm arris all edges Backing rod & sealant Weep 900 crs Non structural conc. veneer Rigid insulation Structural conc. panel Bolted plate connection countersunk to maintain flush surface. Oversize hole in plate to allow for potential movement. CORNER JOINT Structural conc. panel Structural conc. panel 10mm - 20mm joint 6mm arris all edges Backing rod & sealant Weep 900 crs Bolted plate connection countersunk to maintain flush surface. Oversize hole in plate to allow for potential movement. Non structural conc. veneer Structural conc. panel VERTICAL JOINT 68

62 Precast Concrete Details Miscellaneous details It is important to limit heat conduction through cold bridges by insulating adequately. This detail shows rigid insulation fixed to the back face of the concrete parapet to limit this transfer. Plywood is fixed over this as a substrate for the butyl rubber roofing membrane. An aluminium extrusion is used to secure the end of the butyl and provide a crisp edge to the parapet. Continuous aluminium angle screw fix over butyl membrane 18mm construction ply capping to falls screw fix to parapet Butyl roofing membrane on 18mm construction ply on rigid insulation Conc. topping to falls Precast conc. flooring units WALL TO ROOF Continuous steel angle support bracket Structural conc. panel The open web steel framing members allow a spacious ceiling, reminiscent of warehouse structures. This can add architectural interest and allow long spans, but sound transmission can be a problem. Rigid insulation Timber flooring Open web floor framing members Structural conc. panel Continuous steel angle support bracket INTERMEDIATE FLOOR 69

63 residential concrete detailing and specification guide Steel joinery details Rigid insulation fixed on site over conc. panel Acrylic plaster system PVC head flashing screw fixed to concrete panel HEAD DETAIL Mild steel fixing plate cast into concrete reveal Mild steel fixing blocks welded to plates Mild steel window frame Steel door and window sections are regaining popularity with designers in many circumstances. Steel frames are narrower than aluminium or timber therefore presenting a finer line in the elevation design. These details indicate the window frame screw fixed to steel fixing blocks which have been welded to steel plates cast into the opening reveal. Inside, the window reveal is left as natural concrete, placing high requirements on the standard of finish in this area. PVC angle flashing screw fixed to concrete panel Rigid insulation fixed on site over conc. panel Acrylic plaster system Mild steel window frame Mild steel fixing blocks welded to plates Mild steel fixing plate cast into concrete reveal JAMB DETAIL Folded GMS flashing painted to match frame Mild steel window frame Mild steel fixing blocks welded to plates Sloping sill tile adhesive fixed. Cut around frame fixings Mild steel fixing plate cast into concrete reveal Rigid insulation fixed on site over conc. panel Acrylic plaster & waterproofing system SILL DETAIL 70

64 Precast Concrete Details Timber window details Timber joinery can be an attractive design option in an exposed concrete wall. The colour, texture and substance of exposed timber is a positive choice in this detail. It is critical to plan for adequate fixings for the frame, and to separate the timber frame from the concrete by DPC. Rigid insulation fixed on site over conc. panel Acrylic plaster system Backing rod & sealant PVC head flashing Precast conc. panel 10mm arris Timber architrave. Scribe cut. Timber sash & sill Counter sunk & plugged fixing HEAD DETAIL Counter sunk & plugged fixing Sealant Timber frame on packing Flashing Rigid insulation fixed on site over conc. panel Acrylic plaster system Precast conc. panel JAMB DETAIL Counter sunk & plugged fixing Timber sash & sill Sealant Sloping sill Timber architrave Flashing under sill SILL DETAIL 71

65 residential concrete detailing and specification guide Aluminium window details External waterproofing system Reinforced concrete wall Form drip PVC angle cast-in as flashing raglet. Fill with sealant over flashing HEAD DETAIL Insulation Interior lining Building paper Timber strapping Timber reveal A step in the concrete reveal is formed and maintained by the casting in of a PVC angle. The window frame is fitted against the angle with a space allowed for sealant. The exterior face of the concrete is shown to be sealed. The sealer should be applied to the concrete around the window opening before installation of the frames. A second line of defence is the building paper. Timber reveals give a more traditional appearance inside. The insulation in this example separates the thermal mass from the internal space. Timber reveal PVC angle cast-in as flashing raglet. Fill with sealant over flashing External waterproofing JAMB DETAIL Timber strapping Interior lining Building paper Insulation Position framing to allow drainage from within Flashing Tiled sill Timber strapping External waterproofing system Interior lining Insulation Building paper SILL DETAIL 72

66 Precast Concrete Details Aluminium door details These details demonstrate the use of intermittent cast-in fixing blocks around the entire opening, a practice quite common in ICF detailing. Blocks are about 150 mm long and placed at approximately 450 mm centres. The step for the door frame, allows a more positive weathering detail. It is achieved by stopping the external installation short of the concrete edge. Internally the concrete can be left exposed and the edges are shown to be arrised. Sealant here is used architecturally to conceal the packing space between the concrete and the timber reveal. This detail requires close tolerances which can be achieved with precast concrete. Rigid insulation fixed on site over conc. panel Acrylic plaster & waterproofing system PVC head flashing HEAD DETAIL Structural conc. panel Sealant over packing space Timber reveal PVC flashing Rigid insulation fixed on site over conc. panel Acrylic plaster & waterproofing system JAMB DETAIL Sealant over packing space Intermittent timber blocks. Fix galv. nails skew nailed to timber & cast in concrete infill. Structural conc. panel Aluminium door frame over sill flashing Aluminium door frame with timber reveals Shaped timber on DPC Reinforced conc. slab Reinforced Acrylic plaster system over slab edge Paving level SILL DETAIL 73

67 residential concrete detailing and specification guide Non structural conc. veneer Insulation Head flashing Intermittent timber fixing block 6mm arris to all exposed edges Timber door details These timber door frames are shown to mask the exposed edge of polystyrene sheeting. Fixing for the frame is by plug and screw into the concrete. Architrave profile has been scribe cut to follow concrete. HEAD DETAIL Timber frame Counter sunk & plugged fixing Sealant Flashing Timber architrave Non structural conc. veneer Insulation Structural conc. panel JAMB DETAIL Intermittent timber fixing block Recessed timber door & sill Butyl rubber sill flashing Floor coverings Reinforced conc. slab Non structural conc. veneer Insulation Paving level Structural conc. panel SILL DETAIL 74

68 Precast Concrete Details Services installation Electrical and other cable services can be easily accommodated by all precast concrete systems with adequate planning. These details indicated conduits cast into the concrete panels from ceiling to skirting level. In this example, the actual service point is located in a deep skirting. Internal gutter WALL TO ROOF Window section Services flush box cast into wall PVC or metal conduit cast into wall Services flush box cast into wall Skirting Externally insulated concrete wall Services face plate mounted to skirting Reinforced concrete slab WALL TO FLOOR 75

69 Concrete Cast In-Situ Concrete Cast In-Situ General Design Issues Specification Construction Details

70 Concrete Cast In-Situ In-situ concrete is the traditional form of concrete construction. Until the early part of the 20th century it was the main method used. While in-situ concrete above ground level is used less in New Zealand with the advent of precast systems, it still widely used in many other countries. Systems are being developed and used in both Europe and the U.S. to allow cast in place concrete to be cost and time efficient. In developing parts of the world, in-situ concrete, which relies on higher labour input than other forms of concrete construction, is still dominant. In New Zealand it is often not cost effective to design traditional load bearing cast-in-situ concrete structures in the face of competition from precast and modular systems. There are however some situations where in-situ is the ideal structural material, such as building sites that have difficult access. Cast in-situ concrete has become a material that designers exploit for its structural qualities above all else. The chance to cast monolithic building elements walls, columns, beams, suspended floors and roofs which are beautifully detailed appeals to many designers both in New Zealand and offshore. The work of Le Corbusier, Louis Kahn, Carlo Scarpa and more recently Tadao Ando in Japan is familiar to many. The perception of their work is very closely linked to their ability to exploit the qualities of in-situ concrete. Briefly, they are: limitless flexibility of size and shape with no modular restrictions. Current developments in the U.S. are toward entire buildings being poured monolithically. a wide variety of surface textures and colours can be achieved. it can be cast as a sandwich incorporating an integral polystyrene sheet insulation. a robust material which does not require much maintenance it is a universally available material. A house designed by the renowed architect Enrique Norten in Mexico City. 79

71 residential concrete detailing and specification guide design issues Most of the design issues begin and end with the formwork possibilities. The major cost of any cast concrete is that of the formwork. The relative cost of this element is reduced significantly when the formwork is able to be re-used. However repetitive uses on the same project suggests the need for construction joints. Construction joints occur between different placements of concrete. The detail and set out of these joints should be practical and coordinated with the overall design of the project. These joints can be unsightly if not properly planned and constructed. The colour of the concrete can vary slightly from one batch to the next. In large wall or soffit areas it may be desirable to introduce many joints in a pattern, some as construction, others as dummy joints to mask the impact. In addition to construction joints, it may be necessary to provide control joints to allow for shrinkage and thermal movements in walls. These joints should be shown on the drawings. As a general rule, for domestic construction, control joints should be placed at 6 metre centres. Work closely with the builder to understand his strategies for use of formwork on the particular job; and with the structural engineer, who can advise specific requirements for shrinkage control joints. The effective construction of formwork is the key to in-situ concrete walls The desire for a particular surface finish or look may have drawn the designer to cast in-situ concrete. There are many textures and combinations thereof that have been explored to date. No doubt there are an equal number that have not. Some possibilities are: board formed surfaces, achieved by constructing the formwork of roughsawn timber planks. The boards can be arranged in a pattern which will be mirrored in the final product. exposed aggregate this is more difficult with in-situ concrete than with precast, but it can be done by washing the surface with acid. The use of a retarding agent combined with waterblasting is an effective method of achieving an exposed aggregate finish. fairface surface finish with a pattern of holes created by the removal of formwork ties. This finish has been made popular recently by Japanese architects and is achieved through careful consideration of the formwork and casting processes. coloured concrete. Oxides and pigments can be used to tint the concrete to a wide variety of colours. In-situ concrete is only as good as the formwork, which must cope with dynamic loading during the placement and consolidation phases of work. Shuttering can bulge, settle and lean, all of which have the potential to induce small variations in the structure. In addition, the concrete will shrink as it dries. Detailing must therefore consider these and allow adequate tolerances. 80

72 Concrete Cast In-Situ Edge details should take into account the difficulty of filling all corners of the formwork with concrete. Concrete may not find its way into corners, leaving them vulnerable to being damaged during removal of the formwork. It is recommended practice to soften these edges with a chamfer or bullnose or, at minimum, a bead of sealant in the corner of the form smoothed out with a finger. As discussed earlier, load bearing walls are not the only form insitu concrete may take. The designer can consider a column and beam structure with infill or hung curtain wall or claddings. Such systems can also be used in combination with walls. Such a concrete structure would have the advantages of allowing large internal and perimeter spans which will give opportunities for expansive open walls spaces and access to sun and views. The use of cast in-situ floor and roof planes can give the benefits of concrete systems such as acoustic and thermal performance. The concrete can be left exposed from below due to its monolithic form. Formwork for a suspended concrete floor. specification The written specification for in-situ can follow the form of specifications for commercial work with a greater emphasis placed on workmanship issues. Standards NZS 3104 Concrete production high grade and special grade NZS 3109 Concrete construction NZS 3114 Concrete surface finishes NZS 3402 Steel bars for the reinforcement of concrete NZS 3422 Welded fabric of drawn steel wire for concrete reinforcement NZS 3604 Light timber frame buildings not requiring specific design NZS 3101 Concrete structures standard NZS 3610 Formwork for concrete Board formed concrete texture. 81

73 residential concrete detailing and specification guide Formwork construction to achieve a board formed texture. Insulation and waterproofing As with all concrete wall systems, in-situ concrete must be waterproofed and insulated to meet NZBC requirements. Most often waterproofing is achieved by the use of acrylic paint and/or plaster systems. Insulation may be placed on either interior or exterior faces or may be cast within the wall. One strategy for the formation of a construction joint. Materials Reinforcing Bars Bars are to be to the requirements of NZS 3402 Spacers and Chairs Precast concrete or purpose made moulded PVC to approval. Concrete spacer blocks to only be used where the concrete surface is not exposed in the finished work. Ready Mixed Concrete High or Special grade to NZS3104. Maximum aggregate size 19 mm. Concrete strength as specified by the engineer. 82

74 Concrete Cast In-Situ Construction joint and rebates set out to a pattern. Note the use of plastic waterstop. Concrete shall not be allowed to free fall more than 2 metres in any oneplacement operation. This is an important consideration where the construction details call for the height of the wall to be cast in one operation. Curing of concrete to occur for the first seven days after placement. This is generally done by keeping exposed surfaces moist during that time. If any curing compounds are to be used they must first be approved by the designer and checked that they will not adversely affect the application of finishes. construction The exposed soffit of an in-situ concrete floor above. Workmanship Require that all formwork and reinforcing be inspected and approved prior to the concrete being placed. Allow to build in all bolts and fixings as required by other trades and as shown in the drawings. This is an important consideration particularly for the main contractor who is responsible for facilitating the coordination between trades. Minimum concrete cover shall comply with table 5.5 of NZS3101 but shall in no circumstances be less than 40 mm. Where concrete is cast against ground the minimum cover shall be 75 mm, or 50 mm if using a damp proof membrane between the ground and the concrete. Pumping and placement of concrete is to be in accordance with NZS Coordinate with the supplier of the concrete to ensure appropriate specification of the concrete mix. Formwork Planning the efficient and effective use of formwork is critical to the success of in-situ concrete. The nature of the formwork will depend on the designer s objectives. It is important to consult with the designer regularly throughout the process to ensure the formwork is appropriate. Equally, the designer must consider, at an early stage, the way in which the formwork will be made. Poor communication between the designer and builder can result in diminished quality or cost escalation. The formwork must be constructed to accommodate the plastic of concrete which has a mass of approximately 2400 kg/m 3. The general requirements are set out in NZS Setting out While it is critical to get things right with in-situ concrete, it is not a construction method of high technology. It is important to coordinate all services, rebates, penetrations and surface finish requirements before concrete is placed in the forms. 83

75 residential concrete detailing and specification guide Weather conditions Concrete should not be cast in wet or cold conditions. NZS 3109 provides guidance on precautions that should be taken for hot or cold weather concreting. Interestingly, in places like Canada and Scandinavia, concrete is placed in cold conditions throughout the winter. This often requires extensive heating of formwork which is not justifiable in our relatively mild climate. Moisture Only a small proportion of the water in concrete is required for adequate hydration of the cement to occur. The excess water must not be allowed to escape too quickly as it is required for the curing process. This is especially important in the first 7 days. An early house built in Wellington combining in-situ walls with precast concrete roof elements. Conversely, after casting is completed it is desirable for water to escape quickly to allow timely application of finishes. Concrete dries at a rate of about 25 mm per exposed surface per month, depending on the time of year. This implies that a 100 mm concrete wall will take around 2 months before moisture sensitive finishes can be applied. Construction programmes must allow for adequate natural drying to occur. Forced drying, through heating, is not recommended due to the unevenness in drying. Often it is just the surface which is dry. Contractors are advised to check moisture levels with appropriate measuring equipment and to coordinate with the manufacturers of applied finishes. 84

76 Concrete Cast In-Situ Details Sandwich construction details These details of the external envelope indicate how proprietary polymer ties and polystyrene insulation board can be used in an in-situ application. This form of construction is best known in its precast context. The formwork must be set up to allow the insulation to remain in place while the concrete is placed in both faces. This is best done by balancing the pour to both faces up the height of the wall. At suspended floor level the wall is cast full height eliminating the need for a construction joint. In this case the chosen concrete floor system is supported on a steel angle bolted to the finished wall. At ground floor level the in-situ wall is connected to the slab and foundation by starter bars. The outside veneer face has weep holes formed to allow any water that enters above to trickle down the face of the insulation and escape without affecting the internal space. Butyl into chase cast in concrete wall Reinforced outer wythe Proprietry Insulation system cast into concrete Composite Connector WALL TO ROOF Proprietry Insulation system cast into concrete Composite Connector Butyl on plywood Insulation laid to a fall Hollow precast unit landed on structural wall Reinforced Concrete wall Hollow core flooring units & conc. topping Reinforced Concrete wall INTERMEDIATE FLOOR Proprietry suspended ceiling Proprietry Insulation system cast into concrete Composite Connector Weep hole formed at base of wall Wall keyed into slab Reinforced Concrete slab 150 MIN 100 MIN Paved G.L. Unpaved G.L. Concrete footing starter bars at required spacing Sand blinding on compacted hardfill DPC WALL TO FLOOR 85

77 residential concrete detailing and specification guide Dress butyl roofing into groove & seal Form drip Commercial glazing section 80mm. Bed on sealant WALL TO ROOF Frame on sill section. Bed on sealant Construction joint Upstand beam Butyl on plywood on insulation laid to falls Concrete column Cast in-situ floor. Exposed soffit In-situ floor and roof plane detail One of the great advantages of in-situ concrete is the ability to create soffits that can be left exposed for reasons of aesthetics, cost and thermal mass. These details indicate at upper level how such a roof can be supported on cast in-situ or precast concrete columns. This will allow expansive areas of glass to be used. At the lower level the in-situ wall is left exposed externally and insulated inside. Corbels and wall thickenings transfer the structural loads from above. The external walls are cast before the ground floor slab, enabling a controlled environment which may suit some finishes. Clear sealer on in-situ formedwall columns Plasterboard lining on strapping & building paper & insulation between. INTERMEDIATE FLOOR Clear sealer on in-situ formed wall Starter bars at required spacing Plasterboard lining on strapping & building paper with insulation between. Ground & polished concrete floor slab on DPC Sand blinding on compacted hardfill Reinforced concrete footing WALL TO FLOOR 86

78 Concrete Cast In-Situ Details External wall details Flashing In-situ comcrete allows the designer to incorporate profiles and features which may not be possible with other forms of constrcution. An integral gutter, or any other profile, is able to provide architectural relief while serving a practical purpose. At suspended floor level there may be a need to incorporate construction joints as part of the overall wall pattern. It is important to specify the appropriate joint profile and make allowances for barriers to water ingress. At foundation level, openings may be necessary for a variety of reasons, in this case to ventilate the crawl space. Waterproofing membrane on cast in-situ gutter Cast Insitu Concrete Wall. Exposed. Waterproofing WALL TO ROOF Cast Insitu Concrete Wall. Exposed. Joint detailed to express rather than hide the joint Construction joint Timber rafters Insulation above suspended ceiling Stringer bolted to conc. wall. Countersink bolt head Internal Linings. Insulation. Internal Linings. Building Paper. Continuous. Timber strapping on DPC. Reinforced concrete slab Construction joint PVC waterstop cast into lower part Precast flooring unit INTERMEDIATE FLOOR Reinforcing as required Stringer bolted to wall Vent openings Insulation. Internal Linings. Building Paper. Continuous. Timber floor on floor joists Conc. dish channel Insulation foil faced Cast in-situ concrete wall Starter bars at required spacing. Reinforced concrete footing WALL TO FLOOR 87

79 residential concrete detailing and specification guide Cast in-situ reinforced concrete upstand wall Overflow pipe FALL Spaced timber decking Butyl rubber membrane on plywood on furring to falls Rigid insulation between furring strips Roof parapet details This roof is used as a trafficable deck with top laid insulation. The concrete soffit is left exposed internally, supported on columns rather than walls. The veneer wall in this example is internal, stopping short of the roof structure to avoid being loaded structurally. Drip edge Commercial glazing section 75mm Cast in-situ conc. slab Conc. column GLASS WALL TO ROOF FALL Butyl rubber membrane on 18mm ply on furring to falls Dress butyl into raglet and seal Rigid insulation Conc. topping Hollow core conc. slab Structural concrete wall MS angle to support roof slab Detail joint edges in sympathy with other edge details Composite connector WALL TO ROOF Suspended ceiling and insulation Cast in-situ wall sandwich construction Detail joint edges in sympathy with other edge details Conc. veneer panel Construction joint EXTERIOR 10mm gap. Backing rod & sealant Composite connector INTERIOR Concrete structural panel This plan view of the vertical joint in a sandwich type wall suggests the edges are formed in sympathy with other joint details. Weathersealing is by sealant over backing rod, a minimum 10 mm gap is necessary. CONSTRUCTION JOINT 88

80 Concrete Cast In-Situ Details Aluminium door details These walls are insulated and lined internally, giving a more traditional appearance. At the head, a rebate is cast in by a removable insert in the formwork. This delicate operation allows the head flashing to be seated securely. At sill level, the concrete slab edge should be set back to allow the threshold to overhang. Reinforced conc. cast in-situ Head flashing HEAD DETAIL Internal lining Intermittent H3 timber blocks. Fix galv. nails skew nailed to timber & cast-in concrete infill. Timber reveal Aluminium door frame with timber reveals Aluminium subframe 2 beads of sealant Timber reveal Continuous timber packer Timber strapping JAMB DETAIL Aluminium door frame with timber reveals Aluminium door frame over sill flashing Shaped timber sill on DPC Reinforced conc. slab Step back concrete slab edge to suit reveal SILL DETAIL 89

81 residential concrete detailing and specification guide External insulation fixed to concrete External waterproofing system Flashing Timber window frame and sash Reinforced concrete cast in-situ exposed finish Timber H3 fixing block cast-in Timber architrave Timber door details These externally insulated walls have a pronounced chamfer on the internal reveal edge. The frame, positioned in the centre of the finished wall, is fixed to cast in fixing blocks at head and jambs. Note the architrave, which is scribe cut to the reveal. Weatherseal at the jambs is sealant, which will require periodic maintenance. HEAD DETAIL Sealant & backing rod Timber architrave Corner protection External insulation fixed to concrete External waterproofing system Timber H3 fixing block cast-in JAMB DETAIL Timber door & sill. Recess sill into slab. Butyl rubber sill flashing Flooring Reinforced conc. slab External insulation fixed to concrete Paving level SILL DETAIL 90

82 Concrete Cast In-Situ Details Aluminium window details This set of details indicate the use of domestic joinery profiles in a concrete wall which is strapped and lined internally. The insulation is placed between the strapping. The window frame is shown fitting flush to the outside. While sealants provide adequate weathering at the jambs, at the head a flashing is shown fitted into a formed rebate. Note that it is advisable to have the window supplier measure the opening after the formwork has been stripped. This detail has not incorporated timber fixing blocks for the frame. Therefore, it will be necessary to install the frame by screw fixing into plastic plugs fitted into drilled holes in the concrete. It is important to wait until the concrete has gained adequate strength before drilling. External waterproofing Reinforced concrete wall cast in-situ Form drip PVC angle cast-in as flashing raglet. Fill with sealant over flashing Glazing in aluminium window frame HEAD DETAIL Glazing in aluminium window frame Insulation Interior lining Building paper Timber strapping Timber reveal Timber reveal PVC angle cast-in as flashing raglet. Fill with sealant over flashing Timber strapping Interior lining External waterproofing Building paper Insulation JAMB DETAIL Position framing to allow drainage from within Flashing Timber reveal External waterproofing/ plaster/tiled Timber strapping Reinforced concrete cast in-situ Interior lining Insulation Building paper SILL DETAIL 91

83 residential concrete detailing and specification guide External insulation fixed to concrete External waterproofing system Cast-in H3 timber fixing block Flashing Timber window frame and sash HEAD DETAIL Reinforced concrete cast in-situ exposed finish Sealant & backing rod Timber window details The timber window frame is fitted into a wall with external rigid insulation and applied acrylic plaster as the weatherproofing. Flashing details are incorporated using the proprietary flashings that can be ordered with most External Insulating Finishing Systems. Note the use of fixing blocks cast into the opening allows the frame to be installed in a manner using standard nail fixings. The frame is set to the depth of the wall and is held away from the concrete visually by a 5 10 mm negative joint. The joint lacks the crispness that may be possible with lightweight linings, but it is important to respect the nature of the concrete materials and allow the chamfer as shown here. Sealant & backing rod Corner protection Cast-in H3 timber fixing block Sealant & backing rod Reinforced concrete cast in-situ exposed finish JAMB DETAIL Timber internal sill Timber sill and sash Galvanized metal sill flashing Timber packer External insulation fixed to concrete External waterproofing system Reinforced concrete cast in-situ exposed finish SILL DETAIL 92

84 Concrete Cast In-Situ Details Steel door and window details External waterproofing Rigid insulation Steel windows are regaining popularity in the residential construction market. Fixing of the window frames to the structure is by way of lugs welded onto the frame before delivery to the site. These lugs are screw fixed to intermittent timber fixing blocks, the positions of which must be coordinated with lug positions. Frames are fitted against a PVC angle held in the formwork by the fixing blocks. The angle will stabilise the concrete edge and provide suitable backing for sealant. Reinforced concrete wall cast in-situ Form drip Continuous sealant bead in PVC angle Glazed hinged door in steel frame HEAD DETAIL Cast-in H3 timber fixing blocks Continuous timber fixing block Timber reveal Glazed hinged door in steel frame Timber reveal Sealant in cast-in PVC angle Continuous timber fixing block Cast-in H3 timber fixing blocks Rigid insulation JAMB DETAIL Steel door frame sill & Timber threshold Flooring Silicon sealant Sloped paving Reinforced concrete slab SILL DETAIL 93

85 residential concrete detailing and specification guide Internal gutter WALL TO ROOF Window section Services flush box cast into wall PVC or metal conduit cast into wall Services flush box cast into wall Skirting Services It is possible to cast-in allowance for services in concrete walls. It is important to coordinate this provision with the structural engineer and the relevant subtrades. Electrical services generally drop from the ceiling in the space to be served which demands a long conduit drop. An alternative would be to extend the service from the level below. Be sure to allow sweeps in the conduit both at the top and bottom to allow the cables to be drawn easier. It may be prudent to allow spare capacity or spare dropper points for future alterations. Externally insulated cast in-situ concrete wall Services face plate mounted to skirting Reinforced concrete slab WALL TO FLOOR 94

86 General Information References Websites ConcreteNetwork.com (1999). ConcreteNetwork.com [Online]. Available: [2000, June 30] Gates & Sons, Inc. (1997). Concrete gates forming systems: concrete forms [Online].Available: [2000, July 7] Insulating Concrete Form Association. Insulating Concrete Form Association [Online]. Available: [2000, July 7] Portland Cement Association. Insulating concrete forms: a better way to build a better home [Online]. Available: [2000, July 7] Precise Forms, Inc. Precise forms [Online]. Available: [2000, July 7] Formasera AB. Formasera AB [Online]. Available: [2000, July 7]. Books Ambrose, J. (1997). Simplified design of concrete structures ( 7th ed.). New York: John Wiley & Sons Inc. Brand, R. (1990). Architectural details for insulated buildings. USA: Van Nostrad Reinhold. BRANZ house insulation guide. (1995). Wellington, [N.Z.]: BRANZ Publications. Bulleyment, A. (1998). Good concrete floors and basements practice. Wellington: BRANZ Publications. Burry, M., & Preston, J. (Eds.). (1999). Construction primer: student edition Wellington: Victoria University of Wellington. Cement mason s guide. (1987). (PA122.04H). Skokie, [Ill]: Portland Cement Association. Childe, H. L. (1969). Everyman s guide to concrete work. London: George Godwin Ltd. Chisholm, D. (1996). Tilt-up technical manual. Wellington: Cement and Concrete Association of New Zealand. Concrete 93 : New Zealand Concrete Society, technical conference and AGM, Waipuna Lodge, Mt Wellington, Auckland, Friday 8 to Sunday 10, October (1993). Wellington: The Concrete Society. Concrete detail design. (1986). London: The Architectural Press. Concrete in housing. (1983). Wexam Springs, [U.K.]: Cement and Concrete Association. Concrete masonry in housing seminar. (1974). Wellington: Concrete Publications Ltd. Concrete: the natural alternative for home building. (1993). Skokie, [Ill]: Portland Cement Association. Dore E. (1983). Suspended concrete ground floors for houses. Wexam Springs, [U.K.]: Cement and Concrete Association. Full brick/block house construction. (1980). Australia: Cement and Concrete Association of Australia. Futagawa, Y. (Ed.). (1991). Tadao Ando: details. Tokyo: A.D.A Edita Tokyo Co. Ltd. Gage, M. (1970). Guide to exposed concrete finishes. London: The Architectural Press. Gjerde, M., & Ingham, J. (1999). Masonry buildings not requiring specific engineering design: part 4.2. Wellington: Cement and Concrete Association of New Zealand. Guide to suspended concrete floors for houses. (1991, May). (T40). North Sydney: Cement and Concrete Association Australia. Kosmatka, S.H. (1991). Finishing concrete slabs with color and texture. Skokie, [Ill]: Portland Cement Association. Masonry villas: detail guide. (3rd ed.). Newmarket: Firth Industries. Panarese, W.C., Kosmatka, S.H., & Randall Jr, F.A. (1991). Concrete masonry handbook: for Architects, Engineers, Builders. Skokie, [Ill]: Portland Cement Association. Prescriptive method for insulating concrete forms in residential construction. (1998). Skokie, [Ill]: Portland Cement Association. Pringle, T. (1998). Good exterior coating practice. Wellington: BRANZ Publications. Reinforced concrete slab floors for houses a selection guide. (1990). Australia: Cement and Concrete Association of Australia; Steel Reinforcement Institute of Australia. Residential concrete. (2nd ed.). (1994). Washington: Home Builders Press. Roller, J.J. (1996). Design criteria for insulating concrete form wall systems. Skokie, [Ill]: Portland Cement Association. Roper, P. (1987). A practical guide to: blockwork. London: International Thompson Publishing. Thermal insulation roofs. (1983, April). (IB023). Porirua: New Zealand Concrete Research Association. Thermal insulation for: insitu/precast concrete walls. (1983, April). (IB022). Porirua: New Zealand Concrete Research Association. Thermal insulation: avoiding risks a guide to good building construction. (1989). Watford, [U.K.]: Building Research Establishment. 95

87 residential concrete detailing and specification guide Thornton, G. (1996). Cast in concrete: concrete construction in New Zealand Hong Kong: South China Printing Company Ltd. Tilt-up housing construction in Victoria. (1990). Melbourne: Cement and Concrete Association of Australia ; Steel Reinforcement Institute of Australia. Tovey, A.K., & Roberts, J.J. (1990). Efficient masonry housebuilding: detailing approach. Wexham Springs: British Cement Association. Tovey, A.K., & Roberts, J.J. (1990). Efficient masonry housebuilding: detailing approach. (48.054). Wexham Springs, Slough: B.C.A. Unifloor: composite steel/concrete floors for dwellings on sloping sites. (1995). Australia: Cement and Concrete Association of Australia. Vanderwerf, P. (et al.). (1997). Insulating concrete forms for residential design and construction. New York: McGraw-Hill. Vanderwerf, P.A., & Munsell, W.K. (1996). Insulating concrete forms: construction manual: successful methods and techniques. U.S.A.: Portland Cement Association. Waddell, J. (1974). Precast concrete: handling and erection. Detroit [U.S.A.]: American Concrete Institute. Waddell, J., & Dobrowolski, J. (3rd ed.) (1993). Concrete construction handbook.. U.S.A.: McGraw-Hill Inc. Wynn, A.E., & Manning, G.P. (1974). Design and construction of formwork for concrete structures. London: Cement and Concrete Association. Articles A concrete opportunity. (1992, June/July). New Zealand Concrete Construction, pp Adrienne R. (1996, December/January). Solid solutions. New Zealand Home and Building, 1: Ardres, R.P., & Fisher, T. (1995, August). How to build concrete homes using foam forms. Aberdeen s Concrete Construction, 40 (8): Barnard, D., & Chisholm, D. (1992, July/August). Swing to concrete housing, cladding. Architecture New Zealand, pp ,74. Burry, M. (1995, September). New technologies. Architecture New Zealand, pp Chisholm, D. (1993, August/September). Residential concrete gets competitive. New Zealand Concrete Construction, pp.5-6, Concrete blocks making them work. (1991, December). Build, pp.7-8. Examples of the use of concrete in residential design. (1991, May). New Zealand Concrete Construction, 35: Insulated precast housing. (1998, August/September). New Zealand Concrete Construction, 42 (4): Lewis, W.R. (1998, August/September). Concrete for New Zealand housing. New Zealand Concrete Construction, 42 (4): 6-9. Mills, M. (1991, March/April). External wall insulation: cladding for refurbishment. The International Journal of Construction Maintenance and Repair, 5 (2): Munsell, W.K. (1995, January). Stay-in-place wall forms revolutionize home construction. Aberdeen s Concrete Construction, 40 (1): Pratley, J. (1993, May). Tilt-up techniques: tilt-up takes on the housing market. Australian Concrete Construction, 6 (2): Priest, J. (1998, August/September). Masonry homes. New Zealand Concrete Construction, 42 (4): Real houses for real people. (1999, December). New Zealand Concrete Construction, 43 (4): Residence in the desert. (1994, February/March). New Zealand Concrete Construction, 38 (1): Sharman, W. (1993, October/November). Good practice the key to durability. Build, pp.33, 34. The Congreve house. (1995, August/September). New Zealand Concrete Construction, 39 (4): Tovey, A. (1998, Spring). Visionary aims and traditional construction. Concrete Quarterly, pp Vanderwerf, P.A. (1996, December). Tips for placing concrete into insulating wall forms. Aberdeen s Concrete Construction, 41 (12): Vanderwerf, P.A., & White, J.G.A. (1998, October). Choosing an insulating concrete form system. Aberdeen s Concrete Construction, 43 (10):

88

NRG 75 CRF NRG GREENBOARD WALL SYSTEM

NRG 75 CRF NRG GREENBOARD WALL SYSTEM NRG GREENBOARD WALL SYSTEM NRG Energy Efficient Building Systems is pleased to announce a revolution in lightweight cladding systems. NRG Building Systems is the first and only company to achieve CodeMark

More information

LAYING BLOCK AND BRICK

LAYING BLOCK AND BRICK LAYING BLOCK AND BRICK Products highlighted in this section: SAKRETE Type N Mortar Mix SAKRETE Type S Mortar Mix Brick And Block Laying Basics The first step in building a brick or block wall is to construct

More information

Linea Weatherboard DIRECT FIX CONCRETE SLAB AND SOFFIT FIGURE 1

Linea Weatherboard DIRECT FIX CONCRETE SLAB AND SOFFIT FIGURE 1 Top plate Stud Soffit lining 45mm min nog Fix scotia bead Building underlay/james Hardie rigid air barrier Soffit Detail Building underlay/james Hardie rigid air barrier Bottom plate 25mm wide cant strip.

More information

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003) NCMA TEK National Concrete Masonry Association an information series from the national authority on concrete masonry technology CONCRETE MASONRY FOUNDATION WALL DETAILS TEK 5-3A Details (2003) Keywords:

More information

EXTERNAL WATERPROOFING MEMBRANES BEST PRACTICE GUIDELINES

EXTERNAL WATERPROOFING MEMBRANES BEST PRACTICE GUIDELINES Building and Construction Industry A joint industry initiative produced by BSA Supershow logo.indd 1 30/01/2008 9:43:29 AM EXTERNAL WATERPROOFING MEMBRANES BEST PRACTICE GUIDELINES FAILING WATERPROOFING

More information

The WANZ Guide to Window Installation

The WANZ Guide to Window Installation The WANZ Guide to Window Installation as described in E2/AS1 Amendment 5 Ver. 1.1 Page 2 of 74 Contents Overview Page 5 Objective Page 5 Scope Page 5 Opening Preparation Page 7 Step P1 Preliminary Check

More information

Chapter 2 Basis of design and materials

Chapter 2 Basis of design and materials Chapter 2 Basis of design and materials 2.1 Structural action It is necessary to start a design by deciding on the type and layout of structure to be used. Tentative sizes must be allocated to each structural

More information

0331 Brick and block construction

0331 Brick and block construction 0331 BRICK AND BLOCK CONSTRUCTION This worksection has been written for Class 1 and 10a buildings that fully conform to the scope of AS 4773.1. If the works include isolated structures, (totally separate

More information

Superform Products Ltd.

Superform Products Ltd. TYPICAL CORNER REINFORCING NOTE : SEE ENGINEERED REBAR SCHEDULES SUPPLIED BY THE MANUFACTURER STEEL REINFORCEMENT WALL CORNER 90 Copyright 2012 Sept. 2012 5.1.1 Rebar Spacing 6" 12" Max. Load LB./FT. 2000

More information

Residential Inspection Guidelines

Residential Inspection Guidelines Residential Inspection Guidelines 201 Pre-Pour Foundation Dimensions Building Location Certificate - if required in the building consent Construction and Advice Notes Check the building dimensions against

More information

DESIGNERS GUIDE TO DOMESTIC CONSERVATORIES

DESIGNERS GUIDE TO DOMESTIC CONSERVATORIES WBCA 403 DESIGNERS GUIDE TO DOMESTIC CONSERVATORIES A guide to assist those intending to install or who are involved in installing conservatories. Includes information about: conservatory and component

More information

Rockwool Flexi Insulation Application Guide

Rockwool Flexi Insulation Application Guide Pitched roof Rafters InterMediate floors INTERNAL partitions external Framed walls separating floors Separating Walls Rockwool Flexi Insulation Application Guide Ground floor The perfect fit for any framed

More information

EAST LYME HIGH SCHOOL

EAST LYME HIGH SCHOOL Overview: 1971 N 1966 GYM 1966 CLASSROOM WING 1966 AUD. 1971 GYM 1998 1998 POOL EAST LYME HIGH SCHOOL Original 1966 Building: The original East Lyme High School was constructed in 1966 and was composed

More information

Document type: Practice Note Title: External and internal membranes Document number: AC2234 Version: 5. 1. Purpose

Document type: Practice Note Title: External and internal membranes Document number: AC2234 Version: 5. 1. Purpose Document type: Practice Note Title: External and internal membranes Document number: AC2234 Version: 5 1. Purpose The purpose of this practice note is to address the incidence of deck and roof membrane

More information

!!!!!! !!! Decra Plus DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 DPSW016 DPSW020 DPSW021 DPSW024 DPSW030 DPSW031 DPSW035 DPSW030 DPSW031 DPSW035

!!!!!! !!! Decra Plus DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 DPSW016 DPSW020 DPSW021 DPSW024 DPSW030 DPSW031 DPSW035 DPSW030 DPSW031 DPSW035 Decra Plus Drawing no DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 Description Shown In Decra Brochure Most Commonly Used Detail t~êã=oççñ=b~îéë=aéí~áä=b~îéë=lîéêü~åö=táíü=fåëìä~íéç=c~ëåá~=~åç=pçññáí

More information

7. Installation. installation 7.1.1. CAST-IN WINDOW SYSTEM 7.1. INSTALLATION OF WINDOW MAIN FRAME

7. Installation. installation 7.1.1. CAST-IN WINDOW SYSTEM 7.1. INSTALLATION OF WINDOW MAIN FRAME 7. Installation Window involves the fixing of window frame at an earlier construction stage and subsequent of the window sashes. This is a highly workmanship dependent process. Only trained and approved

More information

Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit

Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit R-H-DI1 INSULATION BATT NR-E-IB1 Avoid Using Batt Insulation With Metal Framing Batt insulation should not be used with metal framing systems. Although it is common to see fiberglass batt insulation installed

More information

Section 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01.

Section 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01. Section 5.0 Basements Wall insulated externally Product: Polyfoam ECO Ba01 Wall insulated internally Product: Polyfoam ECO Ba02 Basements Basements Basement design Waterproofing BS 8102: 2009 Code of practice

More information

Hanson Building Products. precast basement solutions

Hanson Building Products. precast basement solutions Hanson Building Products precast basement solutions Hanson Building Products Basement Systems Add an extra dimension and combine the inherent flexible, structural and waterproof properties of concrete

More information

Timber Decks. Technical Note. March 2007

Timber Decks. Technical Note. March 2007 Timber Decks Technical Note. March 2007 This Technical Note contains general information for residential timber decks and floor frame structures for veranda s, patios etc which are exposed to the weather.

More information

The WANZ Guide to Window Installation

The WANZ Guide to Window Installation The WANZ Guide to Window Installation as described in E2/AS1 Amendment 5 2 of 60 Contents Overview 5 Objective 5 Scope 5 Opening Preparation 7 Step P1 Preliminary Check 8 Step P2 Cut the Underlay 9 Step

More information

FLASHMAN WINDOW AND DOOR FLASHING SYSTEM. Product. Scope. Appraisal No. 573 [2013]

FLASHMAN WINDOW AND DOOR FLASHING SYSTEM. Product. Scope. Appraisal No. 573 [2013] FLASHMAN WINDOW AND DOOR FLASHING SYSTEM This Appraisal replaces BRANZ Appraisal No. 573 (2007). Amended 05 February 2016. BRANZ Appraisals Technical Assessments of products for building and construction.

More information

If stepping is required, step at 180mm as seen in this picture.

If stepping is required, step at 180mm as seen in this picture. Cast Foundations to standard building regulations requirements. Foundations must be cast completely level, 600mm wide by 230mm deep for single storey, double storey is not allowed by NHBRC. If stepping

More information

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM Chapter 9 STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM 9.1 BACKGROUND Steel is widely used in the construction of multi-storey buildings. However, steel construction is seldom used and is traditionally

More information

The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs

The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs The better way to build TM Installation Manual FOUNDATION SIPs & FROST WALLS SIPs February 2016 PWF FOUNDATION & FROST WALL SIPs Installation Manual Table of Contents Topics General Requirements...................................

More information

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in REV 1-12.12.11/TB002 Technical Bulletin Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in conjunction with TRADA Technology and is intended to provide the reader with introductory

More information

INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS. Multi-Layer Technology provides increased strength.

INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS. Multi-Layer Technology provides increased strength. INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS Multi-Layer Technology provides increased strength. Specifically designed for interior applications. Compatible with most internal

More information

Leaky Homes Financial Assistance Package (FAP) Repair plan example

Leaky Homes Financial Assistance Package (FAP) Repair plan example LEAKY HOMES FINANCIAL ASSISTANCE PACKAGE FACT SHEET Repair Plan Example - June 2014 Page 1 Leaky Homes Financial Assistance Package (FAP) Repair plan example Introduction This repair plan example is intended

More information

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011 CERTIFICATE NAME OF PRODUCT No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011 H-CONTROL REFLEX+ reflective insulating vapour control layer for roof and wall applications MANUFACTURER ACTIS

More information

PART 1 GENERAL 1.1 SECTION INCLUDES

PART 1 GENERAL 1.1 SECTION INCLUDES J-1 Section 09110 Long Form Specification INTERIOR METAL STUD FRAMING This section includes lightweight, usually 0.036 inch (0.9 mm) thick or lighter, non-axial load bearing metal stud framing including

More information

Contents. APA Construction Details. Full fill cavity walls 2-13. Partial fill cavity walls 14-25. Solid externally insulated walls 26-37

Contents. APA Construction Details. Full fill cavity walls 2-13. Partial fill cavity walls 14-25. Solid externally insulated walls 26-37 Contents Pages Full fill cavity walls 2-13 Partial fill cavity walls 14-25 Solid externally insulated walls 26-37 Appendix (BRE confirmation of Ψ and y-values) 38-40 Page 1 of 40 APA Construction Details

More information

Issue of the Guidelines on Prevention of Water Seepage in New Buildings

Issue of the Guidelines on Prevention of Water Seepage in New Buildings graphic: Buildings Department Your REF 來 函 檔 號 :. OUR REF 本 處 檔 號 :.BD GR/1-55/173 FAX 圖 文 傳 真 :..28400451 TEL 電 話 :..2626 1717 www.info.gov.hk/bd To : All Authorized Persons 7 March 2005 Registered Structural

More information

DIY GUIDE 10 EASY STEPS FOR TREATMENT OF RISING DAMP

DIY GUIDE 10 EASY STEPS FOR TREATMENT OF RISING DAMP DIY GUIDE 10 EASY STEPS FOR TREATMENT OF RISING DAMP CONTENTS WHAT IS RISING DAMP STEP 1 SURVEY STEP 2 METER READINGS STEP 3 CONCLUSION STEP 4 PREPARATION FOR TREATMENT STEP 5 TYPE OF TREATMENT STEP 6

More information

Dubai Municipality Standard DMS 1: Part 5: 2004

Dubai Municipality Standard DMS 1: Part 5: 2004 Specification for precast concrete blocks Part 5: Normal-weight concrete-polystyrene sandwich masonry blocks Issue Date Revision Revision Description Prepared by Approved by Authorized by 19/12/2004 Issue

More information

STEP-BY-STEP. construction guide. Delivering better priced Conservatories, Sun Lounges and Garden Rooms via the Internet.

STEP-BY-STEP. construction guide. Delivering better priced Conservatories, Sun Lounges and Garden Rooms via the Internet. STEP-BY-STEP construction guide Delivering better priced Conservatories, Sun Lounges and Garden Rooms via the Internet. Welcome to our CONSERVATORY AND SUNROOM CONSTRUCTION GUIDE What is the specification

More information

Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.

Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high. CI/SfB Tn6 L6813 September 2013 RIW CAVITY DRAIN R20 R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high. Other systems are available for specific uses,

More information

After reading this lesson you will be able to: 12.3 IMPORTANCE OF ROOF 12.4 TYPES OF ROOF IN A HOUSE

After reading this lesson you will be able to: 12.3 IMPORTANCE OF ROOF 12.4 TYPES OF ROOF IN A HOUSE 86 :: Certificate in Construction Supervision (CIVIL) 12 ROOF 12.1 INTRODUCTION The structure provided to cover the house surface (floor) is known as roof. For different situation and requirement, it is

More information

March 14, 2007. Installation of Bay, Bow and Garden Windows

March 14, 2007. Installation of Bay, Bow and Garden Windows March 14, 2007 Re: Installation of Bay, Bow and Garden Windows Attached are the Atrium Companies, Inc recommendation for the installation of bay, bow and garden windows. These instructions were developed

More information

WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12

WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12 WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12 87 88 GOOD INDUSTRY PRACTICES 12 WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12.1 BACKGROUND Most roofs in Singapore are constructed using reinforced

More information

Improving the flood resistance of your home. Advice sheet 4: Flood-resilient walls.

Improving the flood resistance of your home. Advice sheet 4: Flood-resilient walls. Improving the flood resistance of your home Advice sheet 4: Flood-resilient walls. This sheet provides guidance on identifying different types of wall, and reducing the flow of floodwater through them

More information

3 Masonry and Manufactured Stone (Interior and Exterior)

3 Masonry and Manufactured Stone (Interior and Exterior) 3 Masonry and Manufactured Stone (Interior and Exterior) 3.1 Efflorescence (a whitish crystalline powder) is present on masonry surfaces. Efflorescence commonly occurs on masonry surfaces. This is not

More information

PANELIZED HOME INSTALLATION GUIDELINE

PANELIZED HOME INSTALLATION GUIDELINE PANELIZED HOME INSTALLATION GUIDELINE A typical home package will be constructed of Snap-N-Lock Insulated Panels clad with steel skins. 4" panels will be used for the walls, and 6" panels for the roof.

More information

Manual lifting and handling

Manual lifting and handling Manual lifting and handling When installing British Gypsum products and systems care should be taken to ensure that appropriate methods of handling and lifting are adopted. The following guidance details

More information

SG Series 65mm Frame Windows (Fixed Lite Window Illustrated)

SG Series 65mm Frame Windows (Fixed Lite Window Illustrated) (Fixed Lite Window Illustrated) SINGLE LEAF CLADDING / CORRUGATED STEEL (Awning Window Illustrated) SINGLE LEAF CLADDING / FOAM BOARD (Casement Window Illustrated) BRICK VENEER CONSTRUCTION (Horizontal

More information

The compliance of a roof to part of a new house at 28D Rata Street, Oxford, Waimakariri

The compliance of a roof to part of a new house at 28D Rata Street, Oxford, Waimakariri Determination 2009/103 The compliance of a roof to part of a new house at 28D Rata Street, Oxford, Waimakariri 1. The matters to be determined 1.1 This is a determination under Part 3 Subpart 1 of the

More information

Connex. Mortarless Masonry Block System

Connex. Mortarless Masonry Block System Connex Mortarless Masonry Block System Connex Mortarless block wall system from Boral The Boral Connex mortarless system comprises three modular components which key together eliminating the need for mortared

More information

Asphalt Shingle Application Requirements

Asphalt Shingle Application Requirements Alberta Allied Roofing Association Asphalt Shingle Application Requirements Section 1 Roof Decks 1.1 General Asphalt Shingles are not permitted to be installed directly over rigid insulation. When Asphalt

More information

How-To-build guide timber windows

How-To-build guide timber windows How-To-build guide timber windows What you can build using this guide This guide shows you how to install a factory-made timber casement window into a house with a weatherboard cladding. Casement windows

More information

FIRE RATED GLAZING System Guide

FIRE RATED GLAZING System Guide SYSTEM GUIDE Issue date: 05-05-2015 Expiry date: 31-12-2016 System Guide Introduction Pyropanel Developments are specialists in fire rated glazing solutions, and our systems are designed for easy installation

More information

Installation Window Building In Details

Installation Window Building In Details Installation Window Building In Details INSTALLATION Photo courtesy of Rowe Aluminium DATE: NOVEMBER 2009 REPLACES: AUGUST 2003 INSTALLATION Installation Replaces: Scale: NOT TO SCALE Vantage snap-on couplers

More information

How To Repair A Boat Landing Deck With A Boat Bed

How To Repair A Boat Landing Deck With A Boat Bed RESIDENTIAL INSULATED SHEATHING INSTALLATION GUIDE Residential Insulated Sheathing Installation Guide ROXUL COMFORTBOARD IS Table of Contents Slab-on-grade-to Above Grade Wall...1 Foundation Wall at Footing

More information

What you need to know about concrete block basement construction.

What you need to know about concrete block basement construction. Designing and planning your new residence is a vitally important process, which will have a great influence on the future enjoyment of your home. A successful process will ensure all areas of the home

More information

Chapter. Restoration of Damaged Structures

Chapter. Restoration of Damaged Structures 5 Chapter Restoration of Damaged Structures Bringing back a damaged structure to its pre-earthquake state and original strength is called restoration. This is the first step of building rehabilitation.

More information

RESIDENTIAL MASONRY A BEST PRACTICES GUIDE

RESIDENTIAL MASONRY A BEST PRACTICES GUIDE RESIDENTIAL MASONRY A BEST PRACTICES GUIDE Build With Brick Build With Boral CONTENTS BRICK :01 MASONRY CEMENT :03 MASONRY SAND :04 WALL TIES :05 STEEL LINTELS :07 DRAINAGE WALL SYSTEM :09 FLASHING :11

More information

Window Installation Instructions

Window Installation Instructions Caution The correct installation methods of windows in full frame or insert applications is critical towards achieving the tested performance of the window and longterm enjoyment and energy savings for

More information

Post and Beam Construction

Post and Beam Construction Post and Beam Construction A Presentation By the Canadian Wood Council Canadian Conseil Wood canadien Council du bois Early settlers introduced the concept of post and beam construction in North America

More information

Installation Details. D1 General D2 Walls D3 Ceilings D4 Reference. D Installation Details

Installation Details. D1 General D2 Walls D3 Ceilings D4 Reference. D Installation Details D Installation Details D1 General D2 Walls D3 Ceilings D4 Reference D Installation Details D Contents D1 General Installation and Fastening Sequence for Steel Studs D1.1 Fastener Selection D1.3 D2 Walls

More information

Built to Last. Built for Beauty. Good. Solid. Logix. TM

Built to Last. Built for Beauty. Good. Solid. Logix. TM Built to Last. Built for Beauty. Good. Solid. Logix. TM Quality, Value and Service Introducing LOGIX Insulated Concrete Forms. Based on the simple concept of interlocking blocks, LOGIX ICF gives you a

More information

SOUND INSULATION FOR EXTERIOR WALLS AND FACADE SYSTEMS

SOUND INSULATION FOR EXTERIOR WALLS AND FACADE SYSTEMS NOISE TECHNICAL FACT SHEET FACT SHEET 5 SOUND INSULATION FOR EXTERIOR WALLS AND FACADE SYSTEMS The sound insulation of exterior walls and roof-ceiling systems refers to their ability to reduce external

More information

BEST PRACTICE GUIDE. Fibrelime Premixed Universal Plaster and Render

BEST PRACTICE GUIDE. Fibrelime Premixed Universal Plaster and Render BEST PRACTICE GUIDE Fibrelime Premixed Universal Plaster and Render Contents: Fibrelime description Fibrelime suitability Preparation before application Application Aftercare Painting General Recommended

More information

Tested to BS 6375: Part 1: 1989 and achieved a weathertightness classification of 2000 Pa (Special)

Tested to BS 6375: Part 1: 1989 and achieved a weathertightness classification of 2000 Pa (Special) THE B6 GLAZING SYSTEM GLAZING SYSTEMS FOR SEPTEMBER 2013 THE B6 HEEL BEAD SEAL SECURITY GLAZING SYSTEM Page 1 DESCRIPTION The B6 Heel Bead Seal Security Glazing System is suitable for installing all types

More information

PB301 July 2009. Lightweight Building Solutions. Bushfire Protection. www.boral.com.au/bushfireprotection

PB301 July 2009. Lightweight Building Solutions. Bushfire Protection. www.boral.com.au/bushfireprotection PB301 July 2009 Lightweight Building Solutions Bushfire Protection www.boral.com.au/bushfireprotection Attached or adjacent within 6m roofed structures such as garages, carports, verandas and the like,

More information

Ubiflex. Non-lead flashing system

Ubiflex. Non-lead flashing system Ubiflex Non-lead flashing system Ubiflex non-lead flashing Ubiflex is a non-lead waterproof flashing material which can be used in most applications where lead is traditionally used to provide a weatherproof

More information

Common Problems with Walls

Common Problems with Walls Common Problems with Walls Common Problems with Walls There are problems and concerns that are shared by all walls and siding installations. In this article, we will learn about the following commonly

More information

Foundation Experts, LLC Specializes in Foundation Repair and Waterproofing

Foundation Experts, LLC Specializes in Foundation Repair and Waterproofing 1 Most basements show some signs of leaking and cracking. Through the years, problems with water, poor soils, grading, drainage and possible settling affect the integrity of a basement. Being able to recognize

More information

Comment Form on Proposed Gut Rehabilitation Alternatives

Comment Form on Proposed Gut Rehabilitation Alternatives Comment Form on Gut Rehabilitation Alternatives Name: Organization: Email: Instructions Submission: Please submit this form to [email protected] by October 10 th, 2012 with the subject line

More information

PROJECT TITLE : 2-STOREY RESIDENCE LOCATION : ALONG DAANG HARI,MOLINO.BACOOR,CAVITE OWNER : CUEVASVILLE REALTY

PROJECT TITLE : 2-STOREY RESIDENCE LOCATION : ALONG DAANG HARI,MOLINO.BACOOR,CAVITE OWNER : CUEVASVILLE REALTY PROJECT TITLE : 2-STOREY RESIDENCE LOCATION : ALONG DAANG HARI,MOLINO.BACOOR,CAVITE OWNER : CUEVASVILLE REALTY GENERAL SPECIFICATIONS These specifications are intended to cover the construction of the

More information

GYPSUM BOARD, GYPSUM PANEL PRODUCTS AND PLASTER

GYPSUM BOARD, GYPSUM PANEL PRODUCTS AND PLASTER CHAPTER 25 GYPSUM BOARD, GYPSUM PANEL PRODUCTS AND PLASTER User note: Code change proposals to this chapter will be considered by the IBC Structural Code Development Committee during the 2016 (Group B)

More information

BUILDING CONTROL GUIDANCE SHEET USE OF BREATHABLE ROOFING FELTS.

BUILDING CONTROL GUIDANCE SHEET USE OF BREATHABLE ROOFING FELTS. Building Control Charnwood Borough Council Southfield Road Loughborough LE11 2TN BUILDING CONTROL GUIDANCE SHEET USE OF BREATHABLE ROOFING FELTS. Last updated 16/11/2010 Page 1 of 6 PURPOSE: This Guidance

More information

How to build a Pizza Oven in 4 days

How to build a Pizza Oven in 4 days How to build a Pizza Oven in 4 days Preparation day (slab) 1. Foundation 1500 deep x 1300 wide x 75mm deep Required 20 bags cement pre mix. If you already have a concrete base, you save this prep day DAY

More information

cement Masonry Cement Engineered for quality and reliability, Lafarge cements for masonry deliver consistent performance. page 2 Lafarge Cement

cement Masonry Cement Engineered for quality and reliability, Lafarge cements for masonry deliver consistent performance. page 2 Lafarge Cement cement Masonry Cement Engineered for quality and reliability, Lafarge cements for masonry deliver consistent performance. page 2 Lafarge Cement Lafarge in North America The Lafarge Group is the world leader

More information

Good Craftsmanship Guide. Carpentry and Joinery- Carcassing

Good Craftsmanship Guide. Carpentry and Joinery- Carcassing Good Craftsmanship Guide Carpentry and Joinery- Carcassing Introduction This Good Craftsmanship Guide highlights key problems with the major elements of Carpentry and Joinery - Carcassing, and gives guidance

More information

Knauf Aquapanel Interior. Tile Backing. Cement board for wet areas. Will not deteriorate in water. Easy to score and snap

Knauf Aquapanel Interior. Tile Backing. Cement board for wet areas. Will not deteriorate in water. Easy to score and snap Tile Backing Will not deteriorate in water Easy to score and snap Resistant to mould and mildew Knauf Aquapanel Interior Cement board for wet areas Knauf Aquapanel Interior Cement Board Drywall for Wet

More information

DELTA Premium Moisture Management Systems for Foundations.

DELTA Premium Moisture Management Systems for Foundations. DELTA protects property. Saves energy. Creates comfort. DELTA Premium Moisture Management Systems for Foundations. DELTA Premium Moisture Management Systems provide the best protection for foundations.

More information

Module 3.7. Thermal bridging

Module 3.7. Thermal bridging Module 3.7 Thermal bridging Learning Outcomes On successful completion of this module learners will be able to - Describe construction details which influence thermal bridging. 2 Introduction to thermal

More information

Chapter 3 Pre-Installation, Foundations and Piers

Chapter 3 Pre-Installation, Foundations and Piers Chapter 3 Pre-Installation, Foundations and Piers 3-1 Pre-Installation Establishes the minimum requirements for the siting, design, materials, access, and installation of manufactured dwellings, accessory

More information

When considering Roof drainage design the following should be taken into account:

When considering Roof drainage design the following should be taken into account: Roof Drainage Design The primary objective of a gutter or spouting system is to remove water from the roof catchment area and channel that water to the ground drainage. Water ingress can have detrimental

More information

Storage Store the siding in a dry and ventilated area. Do not place it directly on the ground. Always cover the siding after a day s work.

Storage Store the siding in a dry and ventilated area. Do not place it directly on the ground. Always cover the siding after a day s work. Installation Guide Before you begin, take the time to read this entire guide to clearly understand the requirements and steps to follow for proper installation. Warning Do not install defective material.

More information

NRDCA 400 GUIDELINE FOR FIELD APPLICATION of LIGHTWEIGHT INSULATING CONCRETE REROOFING/RECOVER SYSTEMS

NRDCA 400 GUIDELINE FOR FIELD APPLICATION of LIGHTWEIGHT INSULATING CONCRETE REROOFING/RECOVER SYSTEMS NRDCA 400 GUIDELINE FOR FIELD APPLICATION of LIGHTWEIGHT INSULATING CONCRETE REROOFING/RECOVER SYSTEMS The (NRDCA) has prepared this document to provide customers and installers information that the industry

More information

The right solutions. However, it is inevitable that with the introduction of any new construction system the question arises How does it compare?

The right solutions. However, it is inevitable that with the introduction of any new construction system the question arises How does it compare? Value assessment. The right solutions. We Believe We believe that Porotherm offers both short and long term value to all involved in the building process - from bricklayer to client and everyone in between.

More information

Monocouche Best Practice Guide. New-Build Housing Managing movement to avoid cracking

Monocouche Best Practice Guide. New-Build Housing Managing movement to avoid cracking Monocouche Best Practice Guide New-Build Housing Managing movement to avoid cracking Avoiding Cracking For The Designer Visible cracks in render are unsightly and although not hazardous to the construction

More information

December 2013. J-Ply Roofing, Flooring and Decking

December 2013. J-Ply Roofing, Flooring and Decking December 2013 J-Ply Roofing, Flooring and Decking Introduction J-Ply plywood is manufactured in New Zealand by Juken New Zealand Limited (JNL) and marketed by New Zealand Wood Products Limited. The J-Ply

More information

IRISH BUILDING CONTROL INSTITUTE HOTEL COURT HOTEL BALLYCONNELL CO CAVAN. 26 th MARCH 2009 TIMBER FRAME CONSTRUCTION

IRISH BUILDING CONTROL INSTITUTE HOTEL COURT HOTEL BALLYCONNELL CO CAVAN. 26 th MARCH 2009 TIMBER FRAME CONSTRUCTION IRISH BUILDING CONTROL INSTITUTE HOTEL COURT HOTEL BALLYCONNELL CO CAVAN 26 th MARCH 2009 TIMBER FRAME CONSTRUCTION Bill Robinson BSc. C. Eng. M. I. Struct. E. Timber Design Services 1 IS440 Timber frame

More information

PRESENTATION ON REPAIR AND REHABILITATION OF BUILDINGS DAMAGED IN EARTHQUAKE. By H P Gupta & D K Gupta

PRESENTATION ON REPAIR AND REHABILITATION OF BUILDINGS DAMAGED IN EARTHQUAKE. By H P Gupta & D K Gupta PRESENTATION ON REPAIR AND REHABILITATION OF BUILDINGS DAMAGED IN EARTHQUAKE By H P Gupta & D K Gupta DIFFERENT TYPES OF DAMAGES 1.Minor cracks 0.5 to 5 mm wide in load or non-load bearing walls 2.Major

More information

CONCRETE FLOOR SLAB & CASTING BED CONSTRUCTION

CONCRETE FLOOR SLAB & CASTING BED CONSTRUCTION CONCRETE FLOOR SLAB & CASTING BED CONSTRUCTION General 7 www.meadowburke.com 877-518-7665 MB1109 CONCRETE FLOOR SLAB AND CASTING BED CONSTRUCTION Quality Construction Begins at Ground Level Everything

More information

COMMONLY USED RESIDENTIAL BUILDING CODES

COMMONLY USED RESIDENTIAL BUILDING CODES COMMONLY USED RESIDENTIAL BUILDING CODES INTERNATIONAL RESIDENTIAL CODE (2009) form revised 5/10 FOUNDATION 1. DESIGN OF FORMWORK. Section 1906.1 IBC 2009, Section R404.1.2.3.6 IRC 2009, ACI 318 Section

More information

first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel

first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel What is GigaCrete GigaCrete is a family of products based on low carbon footprint Green ceramic binders

More information

necessary for years of satisfactory service. SmartBlock insulating form concrete walls share the

necessary for years of satisfactory service. SmartBlock insulating form concrete walls share the Chapter 7 PLUMBING AND ELECTRICAL 7.1 Introduction to Plumbing and Electrical Consideration of support services such as plumbing and electrical systems from the preliminary schematics phase through final

More information

TFL CUSTOM FIREPLACES WITH MASONRY BRICK LININGS. standard INSTALLATION SPECIFICATION INTO TIMBER FRAMING

TFL CUSTOM FIREPLACES WITH MASONRY BRICK LININGS. standard INSTALLATION SPECIFICATION INTO TIMBER FRAMING 6.CW.1A TFL CUSTOM FIREPLACES WITH MASONRY BRICK LININGS wood or gas standard INSTALLATION SPECIFICATION INTO TIMBER FRAMING The Fireplace Ltd is able to design and fabricate custom brick open masonry

More information

Interior Walls below and above ground OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM

Interior Walls below and above ground OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM P r o d u c t a p p l i c a t i o n s a n d t e c h n i c a l i n f o r m a t i o n 2 below and above ground V OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM V The flexible, fast and cost-effective answer

More information

Additions and Alterations

Additions and Alterations Additions and Alterations Addition and alteration construction is a miscellaneous grouping of home improvement and renovation projects that are generally geared toward the enhancement of an existing principal

More information

Foundation. Foundation

Foundation. Foundation Moisture Aside from structural concerns, the most important consideration for foundation design is moisture. No client wants a wet basement. No client wants a damp basement. No client wants mold in their

More information

Building Control Guidance Note

Building Control Guidance Note Issued 01/01/13 Rev Page 1 of 5 If you intend to convert an existing loft space into additional rooms you will need to apply for Building Regulation Approval. You may also need Planning Permission if you

More information

K2 STONE NATURAL VENEER

K2 STONE NATURAL VENEER INTRODUCTION WHAT IS K2 NATURAL THINSTONE VENEER? Natural K2 Stone veneer is real stone, cut 1 inch thick, making it light enough to be installed as a veneer. Sometimes referred to as thin veneer, thin

More information

Avoiding Air Barrier Pitfalls

Avoiding Air Barrier Pitfalls Avoiding Air Barrier Pitfalls Design & Durability November 2013 Air barriers, when correctly installed, help buildings achieve high levels of energy efficiency by decreasing heat loss. For example, great

More information

The formation of roof waterproofing details calls for

The formation of roof waterproofing details calls for 3.5 BUILT-UP ROOFING DETAIL DESIGN INTRODUCTION The formation of roof details calls for a combination of the skills of the designer and the roofer. There are many different approaches to detail design

More information

The Difference Between Cast Stone and Adhered Manufactured Stone Masonry Veneer

The Difference Between Cast Stone and Adhered Manufactured Stone Masonry Veneer Submitted 9/16/08 For publication - Feb 2009 Masonry Construction Magazine by Bill Russell Chairman, Cast Stone Institute Committee on Educational Standards On many construction documents today, there

More information

Sun Windows General Information Sun New Construction Window Installation Instructions

Sun Windows General Information Sun New Construction Window Installation Instructions Sun Windows General Information Section 1 G F H H H A. Apply Weather Resistive Barrier B. Apply Sill Flashing Tape C. Place Waterproof Sill Shims D. Caulk Back of Nail Fin Sides & Top, Set Window, Fasten

More information

Saint Gobain Gyproc India Ltd. (Formerly India Gypsum Ltd.)

Saint Gobain Gyproc India Ltd. (Formerly India Gypsum Ltd.) Saint Gobain Gyproc India Ltd. (Formerly India Gypsum Ltd.) Gyproc Plasters The cracks in cement sand plaster are an inherent feature which cannot be completely prevented but can only be controlled and

More information

INSTALLATION INSPECTION GUIDE FOR 3RD PARTY INSPECTORS FOR PAREX USA EXTERIOR INSULATION AND FINISH SYSTEMS

INSTALLATION INSPECTION GUIDE FOR 3RD PARTY INSPECTORS FOR PAREX USA EXTERIOR INSULATION AND FINISH SYSTEMS INSTALLATION INSPECTION GUIDE FOR 3RD PARTY INSPECTORS FOR PAREX USA EXTERIOR INSULATION AND FINISH SYSTEMS Introduction This inspection guide is organized to follow the EIF System's Installation Guide.

More information