Electrical Design Standard Symbols

Size: px
Start display at page:

Download "Electrical Design Standard Symbols"

Transcription

1 Electrical Design Standard Symbols 1 1 of 40

2 DOCUMENT NUMBERS INDEX SYMBOLS KEY DIAGRAMS, M. V. AND L. V. ONE LINE DIAGRAMS PAGE CONTROL AND WIRING DIAGRAMS COMMUNICATION SYSTEMS POWER LAY-OUTS LIGHTING LAY-OUTS EARTHING LAY-OUTS CATHODIC PROTECTION 30-3 LOGIC SYMBOLS of 40

3 NOTES 1. SYMBOLS HAVE BEEN DERIVED FROM IEC PUBLICATION 617, NEN 5152 AND COMPANY STANDARDS. EXAMPLE ON SYMBOLS. PUBLICATION EXAMPLE IEC 617 : A 123 IEC COMPANY SEQUENCE INDEX NEN 5152 : NEN-K-13 NON STANDARD (NORM) : NS ALL SYMBOLS MAY BE DRAWN IN ANY POSITION, THE INSCRIPTIONS SHALL REMAIN, HOWEVER IN THE UPRIGHT POSITION. EXCEPTION ARE: A. RELAYS, CONTACTS AND SWITCHES SHALL BE SHOWN SUCH THAT THE MODE OF OPERATION IS FROM LEFT TO RIGHT OR FROM BOTTOM TO TOP. B. INSCRIPTION ON CIRCUIT AND CABLES SHALL BE WRITTEN ALONG THE SYMBOLS AND SHALL BE READ FROM LEFT TO RIGHT OR FROM BOTTOM TO TOP. 3. CONTACTS OF ELECTRICAL OPERATED DEVICES SHALL BE SHOWN IN THE DE- ENERGIZED POSITION. SWITCHES SHALL BE DRAWN IN THE OFF-POSITION OR NOT-ACTIVATED (NO PRESSURE, FLOW, ETC.) 1 3 of 40

4 CONTACTOR CIRCUIT BRACHER DISCONNECTOR (ISOLATOR) OFF LOAD SWITCH-DISCONNECTOR ON LOAD FUSE-DISCONNECTOE OFF LOAD FUSE SWITCH-DISCONNECTOR ON LOAD VOLTAGE INDICATOR CAPACITIVE SYMBOL FOR KEY DIAGRAM, M.V. AND L.V. ONE LINE DIAGRAMS COMPANY DOCUMENT NS of 40

5 NEN-B-45A SINGLE-POLE SWITCH NEN-B-45B TWO-POLE SWITCH NEN-B-45C THREE-POLE SWITCH NEN-B-45D TWO-POLE SWITCH WITH SWITCHED NEUTRAL CONDUCTOR NEN-B-45F FOUR-POLE SWITCH WITH SWITCHED NEUTRAL CONDUCTOR SYMBOL FOR KEY DIAGRAM, M.V. AND L.V. ONE LINE DIAGRAMS COMPANY DOCUMENT NS of 40

6 DELAYED ACTION IN DIRECTION OF MOVEMENT FROM THE ARC TOWARDS ITS CENTRE (DELAYED CLOSING) DELAYED ACTION IN DIRECTION OF MOVEMENT FROM THE ARC TOWARDS ITS CENTRE (DELAYED OPENING) MECHANICAL COUPLING DISENGAGED MECHANICAL COUPLING ENGAGED B OPERATED BY BRAKE MANUAL OPERATED CONTROL, GENERAL CASE EMERGENCY SWITCH (MUSHROOM-TYPE) OPERATED BY HANDWHEEL OPERATED BY LEVER OPERATED BY REMOVABLE HANDLE OPERATED BY KEY OPERATED BY CRANK NOTE: ONLY ACTION IS DESCRIPTED AND A SWITCH IS SHOWN FOR CLARIFICATION. SYMBOL CAN ALSO BE USED FOR CIRCUIT BREACKERS, ISOLATORS A.S.O. SYMBOL FOR KEY DIAGRAM, M.V. AND L.V. ONE LINE DIAGRAMS COMPANY DOCUMENT NS of 40

7 OPERATED BY ROLLER OPERATED BY CAM OPERATED BY SPRING W OPERATED BY PNEUMATIC OR HYDRAULIC CONTROL, SINGLE ACTING OPERATED BY PNEUMATIC OR HYDRAULIC CONTROL, DOUBLE ACTING OPERATED BY ELECTROMAGNETIC ACTUATOR OPERATED BY ELECTRIC MOTOR M OPERATED BY ELECTRIC CLOCK CONTROL BY FLUID LEVEL CONTROL BY FLOW NEN-J-92 OPERATED BY PEDAL NOTE: ONLY ACTION IS DESCRIPTED AND A SWITCH IS SHOWN FOR CLARIFICATION. SYMBOL CAN ALSO BE USED FOR CIRCUIT BREACKERS, ISOLATORS A.S.O. SYMBOL FOR KEY DIAGRAM, M.V. AND L.V. ONE LINE DIAGRAMS COMPANY DOCUMENT NS of 40

8 NEN-J-9 OPERATED BY CENTRIFUGAL FORCE NEN-J-102 OPERATED BY BIMETAL NS-01 HAND RESET B TEMPERATURE SENSITIVE SWITCH NEN-J-61 MAGNETIC OVERCURRENT PROTECTION NEN-J-62 THERMAL OVERCURRENT PROTECTION NEN-J THERMAL AND MAGNETIC OVERCURRENT PROTECTION NEN-J-74 GROUNDFAULT PROTECTION NEN-J-76 UNDER VOLTAGE PROTECTION AUTOMATIC RETURN (THE TRIANGLE IS POINTED IN THE RETURN DIRECTION) MECHANICAL INTERLOCK BETWEEN TWO DEVICES LATCHING DEVICE NOTE: ONLY ACTION IS DESCRIPTED AND A SWITCH IS SHOWN FOR CLARIFICATION. SYMBOL CAN ALSO BE USED FOR CIRCUIT BREACKERS, ISOLATORS A.S.O. SYMBOL FOR KEY DIAGRAM, M.V. AND L.V. ONE LINE DIAGRAMS COMPANY DOCUMENT NS of 40

9 A B MEASURING RELAY OR RELATED DEVICE C INDEPENDENT TIME-LAG INVERSE TIME-LAG CHARACTERISTIC (IDMT) RESIDUAL VOLTAGE U rsd UNDERVOLTAGE U < REVERSE CURRENT I DIFFERENTIAL CURRENT I d PERCENTAGE DIFFERENTIAL CURRENT I d I d /I EARTH FAULT CURRENT I CURRENT IN THE NEUTRAL CONDUCTOR I N SYMBOL FOR KEY DIAGRAM, M.V. AND L.V. ONE LINE DIAGRAMS COMPANY DOCUMENT NS of 40

10 B INSTANTANEOUS OVERCURRENT I >> OVERCURRENT I > UNDERPOWER IP< NEN-K-13 REVERSE POWER P NEN-K-21 MINIMUM IMPEDANCE Z< LOCKED ROTOR n O NEN-K-17 TIME t TEMPERATURE SYMBOL FOR KEY DIAGRAM, M.V. AND L.V. ONE LINE DIAGRAMS COMPANY DOCUMENT NS of 40

11 TRANSFORMER WITH TWO WINDINGS VARIABLE VOLTAGE TRANSFORMER AUTO-TRANSFORMER CHOKE / REACTOR B VOLTAGE TRANSFORMER CURRENT TRANSFORMER CURRENT TRANSFORMER WITH TWO SECONDARY WINDINGS ON THE CORE NS-41 CORE BALANCE CURRENT TRANSFORMER OPEN VEE WINDING, V (60) THREE-PHASE WINDING, DELTA THREE-PHASE WINDING, STAR THREE-PHASE WINDING, STAR, WITH NEUTRAL BROUGHT OUT SYMBOL FOR KEY DIAGRAM, M.V. AND L.V. ONE LINE DIAGRAMS COMPANY DOCUMENT NS of 40

12 THREE-PHASE WINDING, ZIGZAG OR INTERCONNECTED STAR B THREE-PHASE WINDING, ZIGZAG OR INTERCONNECTED STAR, WITH NEUTRAL BROUGHT OUT KILO WATT-HOUR METER kwh KILO VAR-HOUR METER kvarh RECORDING WATTMETER W VOLTMETER V AMMETER A VARMETER var NEN-N- WATTMETER W POWER-FACTOR METER cos FREQUENCY METER Hz NEN-N-6A VOLTMETER WITH 6 POSITIONS SWITCH (NO OFF POSITION) V 6 SYMBOL FOR KEY DIAGRAM, M.V. AND L.V. ONE LINE DIAGRAMS COMPANY DOCUMENT NS of 40

13 SYNCHRONOSCOPE TEMPERATURE CLOCK PULSE METER, COUNTING DEVICE NEN-D-12 TERMINAL PLUG AND SOCKET (MALE AND FEMALE) CONNECTING LINK, CLOSED CONNECTING LINK, CLOSED DIRECT CURRENT ALTERNATING CURRENT NEN-C-1 BUSDUCT NEN-D-36A CABLE CONNECTION NEN-D-39 CABLE GLAND SYMBOL FOR KEY DIAGRAM, M.V. AND L.V. ONE LINE DIAGRAMS COMPANY DOCUMENT NS of 40

14 NS-03 TURBINE T NS-04 DIESEL D A GENERATOR G B MOTOR M C MOTOR WITH WINDING TEMPERATURE DETECTOR M CHARGER / CONVERTER RECTIFIER INVERTER RECTIFIER IN FULL WAVE (BRIDGE) CONNECTION A BATTERY OF ACCUMULATORS OR PRIMARY CELLS A CAPACITOR SYMBOL FOR KEY DIAGRAM, M.V. AND L.V. ONE LINE DIAGRAMS COMPANY DOCUMENT NS of 40

15 A ONE-CONDUCTOR B NEUTRAL CONDUCTOR C PROTECTIVE CONDUCTOR D TWO-CONDUCTORS E ONE-CONDUCTOR WITH NEUTRAL CONDUCTOR G THREE-CONDUCTORS H ONE-CONDUCTOR WITH NEUTRAL CONDUCTOR AND PROTECTIVE CONDUCTOR I TWO-CONDUCTORS WITH NEUTRAL CONDUCTOR J TWO-CONDUCTORS WITH PROTECTIVE CONDUCTOR K TWO-CONDUCTORS WITH NEUTRAL CONDUCTOR AND PROTECTIVE CONDUCTOR L THREE-CONDUCTORS WITH NEUTRAL CONDUCTOR M THREE-CONDUCTORS WITH PROTECTIVE CONDUCTOR N THREE-CONDUCTORS WITH NEUTRAL CONDUCTOR AND PROTECTIVE CONDUCTOR NOTE: WIRE IS ONLY SHOWN FOR CLARIFICATIONS. SYMBOLS CAN ALSO BE USED FOR POWER LAY-OUTS. SYMBOL FOR KEY DIAGRAM, M.V. AND L.V. ONE LINE DIAGRAMS BADGER DOCUMENT NS of 40

16 NS-09 ONE FUSE NS-10 TWO FUSES NS-11 THREE FUSES NS-12 ONE VOLTMETER V NS-13 TWO VOLTMETERS V NS-14 THREE VOLTMETERS V NOTE: SYMBOLS ONLY SHOWN FOR CLARIFICATION SYMBOL FOR KEY DIAGRAM, M.V. AND L.V. ONE LINE DIAGRAMS COMPANY DOCUMENT NS of 40

17 MAKE CONTACT / SWITCH CONTACTOR (CONTACT OPEN IN THE DEENERGIZED POSITION) CIRCUIT BREAKER DISCONNECTOR (ISOLATOR) OFF LOAD SWITCH-DISCONNECTOR ON LOAD FUSE-DISCONNECTOR FUSE SWITCH-DISCONNECTOR (ON-LOAD ISOLATING FUSE-SWITCH) BREAK CONTACT TWO-WAY CONTACT WITH CENTRE-OFF POSITION CHANGE-OVER CONTACT SYMBOL FOR CONTROL AND WIRING DIAGRAMS COMPANY DOCUMENT NS of 40

18 DELAYED ACTION IN DIRECTION OF MOVEMENT FROM THE ARC TOWARDS ITS CENTRE (DELAYED CLOSING) DELAYED ACTION IN DIRECTION OF MOVEMENT FROM THE ARC TOWARDS ITS CENTRE (DELAYED OPENING) MECHANICAL COUPLING, DISENGAGED MECHANICAL COUPLING, ENGAGED B OPERATED BY BRAKE MANUALLY OPERATED CONTROL, GENERAL CASE EMERGENCY SWITCH (MUSHROOM-TYPE) OPERATED BY HANDWHEEL OPERATED BY LEVER OPERATED BY REMOVABLE HANDLE OPERATED BY KEY OPERATED BY CRANK NOTE: ONLY ACTION IS DESCRIPTED AND A SWITCH IS SHOWN FOR CLARIFICATION. SYMBOL CAN ALSO BE USED FOR CIRCUIT BREACKERS, ISOLATORS A.S.O. SYMBOL FOR CONTROL AND WIRING DIAGRAMS COMPANY DOCUMENT NS of 40

19 OPERATED BY ROLLER OPERATED BY CAM OPERATED BY SPRING W OPERATED BY PNEUMATIC OR HYDRAULIC CONTROL, SINGLE ACTING OPERATED BY PNEUMATIC OR HYDRAULIC CONTROL, DOUBLE ACTING OPERATED BY ELECTROMAGNETIC ACTUATOR OPERATED BY ELECTRICAL MOTOR M OPERATED BY ELECTRICAL CLOCK CONTROL BY FLUID LEVEL CONTROL BY FLOW NEN-J-92 OPERATED BY PEDAL NOTE: ONLY ACTION IS DESCRIPTED AND A SWITCH IS SHOWN FOR CLARIFICATION. SYMBOL CAN ALSO BE USED FOR CIRCUIT BREACKERS, ISOLATORS A.S.O. SYMBOL FOR CONTROL AND WIRING DIAGRAMS COMPANY DOCUMENT NS of 40

20 NEN-J-9 OPERATED BY CENTRIFUGAL FORCE NEN-J-102 OPERATED BY BIMETAL NS-01 LOCKING DEVICE, HAND RESET B TEMPERATURE SENSITIVE SWITCH NEN-J-61 MAGNETIC OVERCURRENT PROTECTION NEN-J-62 THERMAL OVERCURRENT PROTECTION NEN-J THERMAL AND MAGNETIC OVERCURRENT PROTECTION NEN-J-74 GROUNDFAULT PROTECTION NEN-J-76 UNDER VOLTAGE PROTECTION AUTOMATIC RETURN (THE TRIANGLE IS POINTED IN THE RETURN DIRECTION) MECHANICAL INTERLOCK BETWEEN TWO DEVICES LATCHING DEVICE NOTE: ONLY ACTION IS DESCRIPTED AND A SWITCH IS SHOWN FOR CLARIFICATION. SYMBOL CAN ALSO BE USED FOR CIRCUIT BREACKERS, ISOLATORS A.S.O. SYMBOL FOR CONTROL AND WIRING DIAGRAMS COMPANY DOCUMENT NS of 40

21 OFF AUTO START CAD NAME DESCRIPTION SYMBOL NS-20 ROTARY SWITCH CONTACT POSITION LEFT NS-21 ROTARY SWITCH CONTACT POSITION LEFT AND CENTER NS-22 ROTARY SWITCH CONTACT POSITION LEFT AND RIGHT NS-23 ROTARY SWITCH CONTACT POSITION CENTER AND RIGHT NS-24 ROTARY SWITCH CONTACT POSITION CENTER NS-25 ROTARY SWITCH CONTACT POSITION RIGHT NS-26 ROTARY SWITCH CONTACT POSITION LEFT AND RIGHT NS-27 ROTARY SWITCH CONTACT NS-2 ROTARY SWITCH RIGHT SLIDING CONTACT NS-29 ROTARY SWITCH LEFT SLIDING CONTACT ROTARY SWITCH SPRING RETURN FROM START PADLOCKABLE IN OFF POSITION SYMBOL FOR CONTROL AND WIRING DIAGRAMS COMPANY DOCUMENT NS of 40

22 NS-30 PADLOCKABLE IN LEFT POSITION NS-31 PADLOCKABLE IN CENTER POSITION NS-32 PADLOCKABLE IN RIGHT POSITION NS-34 ROTARY SWITCH NS-35 ROTARY SWITCH LEFT SPRING RETURN NS-36 ROTARY SWITCH RIGHT SPRING RETURN NS-37 ROTARY SWITCH LEFT & RIGHT SPRING RETURN NS-43 SELECTOR SWITCH SYMBOL FOR CONTROL AND WIRING DIAGRAMS COMPANY DOCUMENT NS of 40

23 A B MEASURING RELAY OR RELATED DEVICE C INDEPENDENT TIME-LAG INVERSE TIME-LAG CHARACTERISTIC (IDMT) RESIDUAL VOLTAGE U rsd UNDERVOLTAGE U < REVERSE CURRENT I DIFFERENTIAL CURRENT I d PERCENTAGE DIFFERENTIAL CURRENT I d I d /I EARTH FAULT CURRENT I CURRENT IN THE NEUTRAL CONDUCTOR I N SYMBOL FOR CONTROL AND WIRING DIAGRAMS COMPANY DOCUMENT NS of 40

24 B INSTANTANEOUS OVERCURRENT I << OVERCURRENT I < UNDERPOWER P< NEN-K-13 REVERSE POWER P NEN-K-21 MINIMUM IMPEDANCE Z< LOCKED ROTOR n 0 ~ NEN-K-17 TIME t TEMPERATURE OPERATING DEVICE, GENERAL SYMBOL (RELAY COIL) OPERATING DEVICE / RELAY COIL WITH TWO SEPARATE WINDINGS RELAY COIL OF A TIME DELAYED RELAY ON DEENERGIZING RELAY COIL OF A TIME DELAYED RELAY ON ENERGIZING NEN-K-3 FLAG-RELAY SYMBOL FOR CONTROL AND WIRING DIAGRAMS COMPANY DOCUMENT NS of 40

25 TRANSFORMER WITH TWO WINDINGS B ISOLATION TRANSFORMER VARIABLE VOLTAGE TRANSFORMER AUTO-TRANSFORMER INDUCTOR/COIL/CHOKE/WINDING CURRENT TRANSFORMER / PULSE TRANSFORMER CURRENT TRANSFORMER WITH TWO SECONDARY WINDINGS ON ONE CORE NS-40 SHORT CIRCUIT DEVICE INDUCTOR WITH MAGNETIC CORE SERIES WINDING SYMBOL FOR CONTROL AND WIRING DIAGRAMS COMPANY DOCUMENT NS of 40

26 KILO WATT-HOUR METER kwh KILO VAR-HOUR METER kvarh RECORDING WATTMETER W VOLTMETER V AMPMETER A VARMETER var POWER-FACTOR METER FREQUENCY METER Hz NEN-N-6A VOLTMETER WITH 6 POSITIONS SWITCH V SYNCRONOSCOPE THERMOMETER (PYROMETER) CLOCK PULSE METER, COUNTING DEVICE SYMBOL FOR CONTROL AND WIRING DIAGRAMS COMPANY DOCUMENT NS of 40

27 NEN-D-12 TERMINAL PLUG AND SOCKET (MALE AND FEMALE) CONNECTING LINK, CLOSED CONNECTING LINK, OPEN DIRECT CURRENT ALTERVATING CURRENT SYMBOL FOR CONTROL AND WIRING DIAGRAMS COMPANY DOCUMENT NS of 40

28 RESISTOR, GENERAL SYMBOL CAPACITOR RESISTOR, VARIABLE, LINEAIR RESISTOR, VARIABLE, NON-LINEAIR RESISTOR PRE-SET ADJUSTMENT HEATING ELEMENT SEMICONDUCTOR DIODE, GENERAL SYMBOL LIGHT EMITTING DIODE, GENERAL SYMBOL TRIODE THYRISTOR TYPE UNSPECIFIED FUSE HRC FUSE SCREW TYPE DIAZED (INCANDESCENT) SIGNAL LAMP PHOTO CELL VOLTAGE INDICATOR CAPACITIVE SYMBOL FOR CONTROL AND WIRING DIAGRAMS COMPANY DOCUMENT NS of 40

29 HORN BELL SIREN TELEPHONE SET, LOUDSPEAKER, TELEPHONE SET WITH LOUDSPEAKER ANTENNA, GENERAL SYMBOL AMPLIFIER LINE POWER UNIT (AC-TYPE) SHOWN SYMBOL FOR COMMUNICATION SYSTEMS COMPANY DOCUMENT NS of 40

30 NEN-C-5-04 CABLE FLAG FOR MAXIMUM OF 4 CHARACTERS NEN-C-5-05 CABLE FLAG FOR MAXIMUM OF 5 CHARACTERS NEN-C-5-06 CABLE FLAG FOR MAXIMUM OF 6 CHARACTERS NEN-C-5-07 CABLE FLAG FOR MAXIMUM OF 7 CHARACTERS NEN-C-5-0 CABLE FLAG FOR MAXIMUM OF CHARACTERS NEN-C-5-09 CABLE FLAG FOR MAXIMUM OF 9 CHARACTERS NEN-C-5-10 CABLE FLAG FOR MAXIMUM OF 10 CHARACTERS NEN-C-5-11 CABLE FLAG FOR MAXIMUM OF 11 CHARACTERS NEN-C-5-12 CABLE FLAG FOR MAXIMUM OF 12 CHARACTERS NEN-C-5-1 FLAG INDICATION NEN-C-5-2 FLAG INDICATION BUNDLE INDICATION SYMBOL FOR LAY-OUTS COMPANY DOCUMENT NS of 40

31 NS-05 PACKAGE UNIT PU NS-06 WELDING UNIT W NS-15 MOTOR OPERATED VALVE (MOV) M NS-16 ELECTRICAL DISTRIBUTION PANEL NS-17 INSTRUMENT PANEL OR BOX NS-1 JUNCTION BOX JB STRAIGHT THROUGH JUNCTION BOX JUNCTION BOX FOR 3 OR 4 CABLES REMOTE CONTROL STATION NS-57 SAFETY SWITCH NS-5 PRIMARY SAFETY SWITCH NS-5 EMERGENCY PUSH BUTTON B MOTOR M SYMBOL FOR LAY-OUTS COMPANY DOCUMENT NS of 40

32 CABLE OR CONDUIT GOING UPWARDS CABLE OR CONDUIT GOING DOWNWARDS NEN-C-46 CABLE OR CONDUIT COMING FROM DOWNWARDS NEN-C-47 CABLE OR CONDUIT COMING FROM UPWARDS NEN-C-50 CABLE OR CONDUIT PASSING THROUGH VERTICALLY UPWARDS NEN-C-51 CABLE OR CONDUIT PASSING THROUGH VERTICALLY DOWNWARDS NS-59 ARROW FOR STAIR INDICATION CONNECTION OF CONDUCTORS NS-44 ARROW HEAD SYMBOL FOR LAY-OUTS COMPANY DOCUMENT NS of 40

33 NEN-J-170 SWITCH, SINGLE POLE SWITCH, TWO POLE MULTI-POSITION SWITCH, SINGLE POLE (TWO CIRCUIT SWITCH) TWO-WAY SWITCH, SINGLE POLE INTERMEDIATE SWITCH DIMMER SWITCH, SINGLE POLE PULL-CORD SWITCH, SINGLE POLE SOCKET OUTLET (POWER) SOCKET OUTLET (POWER) WITH PROTECTIVE CONTACT NS-49 SOCKET OUTLET CONNECTED TO A SAFETY TRANSFORMER SYMBOL FOR LAY-OUTS COMPANY DOCUMENT NS of 40

34 NEN-M-24H FLUORESCENT LIGHTING FIXTURE, 2X20W NEN-M-24I FLUORESCENT LIGHTING FIXTURE, 2X40W NEN-M-24J NEN-M-24K NEN-M-24L NEN-M-24M FLUORESCENT LIGHTING FIXTURE, 2X65W FLUORESCENT LIGHTING FIXTURE, 2X20W (MOUNTED UNDER PLATFORM) FLUORESCENT LIGHTING FIXTURE, 2X40W (MOUNTED UNDER PLATFORM) FLUORESCENT LIGHTING FIXTURE, 2X65W (MOUNTED UNDER PLATFORM) NS-79 FLUORESCENT LIGHTING FIXTURE, WITH EMERGENCY SUPPLY PHOTO CELL NOTE: SYMBOLS TO BE SHOWN ON LAYOUTS PROVIDED WITH A CODE FOR IDENTIFICATION EXAMPLE LIGHTING FIXTURE CODING: A L2 CONNECTED TO PHASE L2 CONNECTED TO CIRCUIT No. 3 FIXTURE MOUNTING IDENTIFICATION SYMBOL FOR LAY-OUTS COMPANY DOCUMENT NS of 40

35 INCANDESCENT OR MERCURY VAPOR LIGHTING FIXTURE, CEILING MOUNTED FLOODLIGHT NS-4 STREET/FENCE LIGHTING FIXTURE, POLE MOUNTED NS-50 ELECTRICAL DISTRIBUTION PANEL NS-51 EMERGENCY HANDLAMP WITH OWN SOURCE NS-52 EMERGENCY EXIT (RIGHT) EXIT NS-53 EMERGENCY EXIT (LEFT) EXIT NS-54 EMERGENCY EXIT (ABOVE DOOR) EXIT NS-55 ILLUMINATED LEVELGAUGE SYMBOL FOR LAY-OUTS COMPANY DOCUMENT NS of 40

36 EARTH/GROUND CLEAN EARTH/GROUND EARTH ELECTRODE IN PIT NEN-D-3 EARTH ELECTRODE NEN-D-2-3 CLEAN EARTH ELECTRODE NEN-D-4 PILE EARTHING FRAME/CHASSIS EQUIPOTENTIAL LIGHTING ARRESTOR NS-45 LIGHTING ROD NS-46 DIVIDING POINT NS-47 CRIMPIT CONNECTION NS-69 SPARK GAP CHOKE SYMBOL FOR LAY-OUTS COMPANY DOCUMENT NS of 40

37 NS-16 DISTRIBUTION BOX NS-60 RECTIFIER, HAND CONTROLLED H NS-61 RECTIFIER, AUTO CONTROLLED A EARTHING NS-62 CADWELD CONNECTION AT PIPELINE NS-63 REFERENCE ELECTRODE E NS-64 REFERENCE ELECTRODE IN PIT E NS-65 MEASURING STATION ON POLE NS-66 MEASURING STATION IN PIT NS-67 NS-6 ANODE FOR IMPRESSED CURRENT (CHEMICAL SYMBOL INDICATES THE MATERIAL SACRIFICIAL ANODE (CHEMICAL SYMBOL INDICATES THE MATERIAL A Mg A Mg SYMBOL FOR LAY-OUTS COMPANY DOCUMENT NS of 40

38 NS-69 SPARK GAP NS-70 ISOLATION (GENERAL) NS-71 ISOLATION FLANGE NS-72 ISOLATION COUPLING NS-73 SCREENING PLATE NS-74 SCREENING CONDUIT NS-75 VALVE WITH ISOLATION FLANGE SYMBOL FOR LAY-OUTS COMPANY DOCUMENT NS of 40

39 OR GATE > AND GATE & NOR GATE > NAND GATE & NEGATOR SCHMITT TRIGGER MONOSTABLE ELEMENT, SINGLE SHOT 1 t DELAY ELEMENT WITH SPECIFIED DELAY TIMES DELAY ELEMENT B VARIABLE DELAY ELEMENT LOGIC SYMBOL 39 of 40

40 AMPLIFIER/REPEATER NEGATION INDICATOR (INPUT) NEGATION INDICATOR (OUTPUT) POLARITY INDICATOR (INPUT) POLARITY INDICATOR (OUTPUT) A INPUT WHICH DOES NOT CARRY LOGIC INFORMATION B OUTPUT WHICH DOES NOT CARRY LOGIC INFORMATION NS-76 CONVERSION FROM DEVICE TO LOGIC LEVEL NS-77 INTERMEDIATE RELAY R LOGIC SYMBOL 40 of 40

Wires & Connections Component Circuit Symbol Function of Component. Power Supplies Component Circuit Symbol Function of Component

Wires & Connections Component Circuit Symbol Function of Component. Power Supplies Component Circuit Symbol Function of Component Lista Dei Simboli Dei Circuiti Per i Componenti Elettronici Wires & Connections Wire Wires joined Wires not joined To pass current very easily from one part of a circuit to another. A 'blob' should be

More information

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000 Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000 Description Firetrol FTA1000 Full Voltage Fire Pump Controllers are intended for use with electric motor driven fi re pumps

More information

Product Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500

Product Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500 Product Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500 Description Firetrol FTA1500 Primary Resistance Fire Pump Controllers use resistors in the line to reduce line voltage

More information

SECTION 20. ELECTRICAL AND ELECTRONIC SYMBOLS

SECTION 20. ELECTRICAL AND ELECTRONIC SYMBOLS 9/8/98 AC 43.13-1B SECTION 20. ELECTRICAL AND ELECTRONIC SYMBOLS 11-271. GENERAL. The electrical and electronic symbols shown here are those that are likely to be encountered by the aviation maintenance

More information

EET272 Worksheet Week 8

EET272 Worksheet Week 8 EET272 Worksheet Week 8 answer questions 1-5 in preparation for discussion for the quiz on Monday. Finish the rest of the questions for discussion in class on Wednesday. Question 1 Questions We will now

More information

NATIONAL CERTIFICATE (VOCATIONAL)

NATIONAL CERTIFICATE (VOCATIONAL) NATIONAL CERTIFICATE (VOCATIONAL) SUBJECT GUIDELINES ELECTRICAL PRINCIPLES AND PRACTICE NQF Level 4 September 2007 ELECTRICAL PRINCIPLES AND PRACTICE LEVEL 4 CONTENTS INTRODUCTION 1 DURATION AND TUITION

More information

BSNL TTA Question Paper-Instruments and Measurement Specialization 2007

BSNL TTA Question Paper-Instruments and Measurement Specialization 2007 BSNL TTA Question Paper-Instruments and Measurement Specialization 2007 (1) Instrument is a device for determining (a) the magnitude of a quantity (b) the physics of a variable (c) either of the above

More information

Cam switches. Page. Overview 4-2. ON-OFF switches, main switches, maintenance switches 4-3. Changeover switches, reversing switches 4-5

Cam switches. Page. Overview 4-2. ON-OFF switches, main switches, maintenance switches 4-3. Changeover switches, reversing switches 4-5 Eaton Wiring Manual / Page Overview - ON-OFF switches, main switches, maintenance switches - Changeover switches, reversing switches - (Reversing) star-delta switches - Multi-Speed Switches - Interlock

More information

Properties of electrical signals

Properties of electrical signals DC Voltage Component (Average voltage) Properties of electrical signals v(t) = V DC + v ac (t) V DC is the voltage value displayed on a DC voltmeter Triangular waveform DC component Half-wave rectifier

More information

Product Description Digital Solid State Starting Electric Fire Pump Controllers FTA1930

Product Description Digital Solid State Starting Electric Fire Pump Controllers FTA1930 Product Description Digital Solid State Starting Electric Fire Pump Controllers FTA1930 Description Firetrol FTA1930 Digital Solid State Starting Fire Pump Controllers feature soft start, soft stop and

More information

Type SA-1 Generator Differential Relay

Type SA-1 Generator Differential Relay ABB Automation Inc. Substation Automation and Protection Division Coral Springs, FL 33065 Instruction Leaflet 41-348.11C Effective: November 1999 Supersedes I.L. 41-348.11B, Dated August 1986 ( ) Denotes

More information

E&I MAINTENANCE ENTRY TEST ENABLING OBJECTIVES. DESCRIBE hazards and precautions taken to avoid injury in the workplace.

E&I MAINTENANCE ENTRY TEST ENABLING OBJECTIVES. DESCRIBE hazards and precautions taken to avoid injury in the workplace. SAFETY Industrial DESCRIBE hazards and precautions taken to avoid injury in the workplace. Example #1: All of the following are common PPE used to perform maintenance activities EXCEPT: a. Safety Glasses

More information

VCE Physics and VCE Systems Engineering: Table of electronic symbols

VCE Physics and VCE Systems Engineering: Table of electronic symbols VCE Physics and VCE Systems Engineering: Table of electronic symbols In response to requests from teachers the VCAA has produced a table of commonly used electronic symbols. Practicing teachers have provided

More information

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS UNIT OBJECTIVES After studying this unit, the reader should be able to Describe the different types of open single-phase motors used to drive

More information

How To Understand The Electrical Power Supply Of A Power Supply System

How To Understand The Electrical Power Supply Of A Power Supply System 17 Circuit diagram symbols E 18 CIRCUIT DIAGRAM SYMBOLS electrical network elements three-phase line or cable single-phase line or cable short circuit earth electrode outgoing feeder supply incoming feeder

More information

Specifying a Variable Frequency Drive s

Specifying a Variable Frequency Drive s Specifying a Variable Frequency Drive s Put on by Bruce Reeves and Jeremy Gonzales Dykman Electrical Covering the Western US For all of your VFD and Soft Start and Motor Needs How To Specify a Variable

More information

Industrial Automation Commonly-Used Terms

Industrial Automation Commonly-Used Terms Engineering Smarter Systems Industrial Automation Commonly-Used Terms A Glossary of Industrial Automation and Control Terms LECINC.COM 1 A Accelerating Time: Across the Line Starter: Action Device: Actuator:

More information

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original A motor starter is a combination of devices to allow an induction motor to start, run and stop according

More information

Chapter 5. Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams

Chapter 5. Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams Chapter 5 Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams Objectives Upon completion of this course, you will be able to: Explain what electrical loads are and their general purpose

More information

Relays High Capacity 50 Amp Mini Relays Standard Mini Relays Micro Relays Power Relays Connector Modules

Relays High Capacity 50 Amp Mini Relays Standard Mini Relays Micro Relays Power Relays Connector Modules CHIEF EN TERPRISES INC. M a s t e r I n t e r n a t i o n a l D i s t r i b u t o r Relays High Capacity 50 Amp Mini Relays Standard Mini Relays Micro Relays Power Relays Connector Modules M AS TER IN

More information

UNIT 3 AUTOMOBILE ELECTRICAL SYSTEMS

UNIT 3 AUTOMOBILE ELECTRICAL SYSTEMS UNIT 3 AUTOMOBILE ELECTRICAL SYSTEMS Automobile Electrical Structure 3.1 Introduction Objectives 3.2 Ignition System 3.3 Requirement of an Ignition System 3.4 Types of Ignition 3.4.1 Battery or Coil Ignition

More information

Power Generation. Power Control PCL System Generator Set Control

Power Generation. Power Control PCL System Generator Set Control Power Generation Power Control PCL System Generator Set Control Solid State Control The Power Control PCL system uses the latest solid state control technology. Designed for the budget-conscious installation

More information

I. R. D. T INSTITUTE OF RESEARCH DEVELOPMENT AND TRAINING

I. R. D. T INSTITUTE OF RESEARCH DEVELOPMENT AND TRAINING I. R. D. T INSTITUTE OF RESEARCH DEVELOPMENT AND TRAINING SYLLABUS SIX MONTHS FULL TIME Repair and Maintenance of Electrical gadgets EFFECTIVE FROM:- UNDER DEVELOPMENT Prepared By: Curriculum Development

More information

Relationship between large subject matter areas

Relationship between large subject matter areas H02M APPARATUS FOR CONVERSION BETWEEN AC AND AC, BETWEEN AC AND DC, OR BETWEEN DC AND DC, AND FOR USE WITH MAINS OR SIMILAR POWER SUPPLY SYSTEMS; CONVERSION OF DC OR AC INPUT POWER INTO SURGE OUTPUT POWER;

More information

TYXIA. *2702178_Rev.1* Installation and User Guide. Wireless receiver. TYXIA RF 642-1 channel

TYXIA. *2702178_Rev.1* Installation and User Guide. Wireless receiver. TYXIA RF 642-1 channel Installation and User Guide TYXIA Wireless receiver TYXIA RF 642-1 channel DELTA DORE Bonnemain - 35270 COMBOURG - France E-mail : deltadore@deltadore.com Unit compliant with the requirements of directives:

More information

Recognizing and understanding schematic symbols will enable you to comprehend a circuit s function.

Recognizing and understanding schematic symbols will enable you to comprehend a circuit s function. Schematic symbols are used to identify and graphically depict the function of fluid power components. Recognizing and understanding schematic symbols will enable you to comprehend a circuit s function.

More information

Thyristor-controlled power supplies and battery chargers

Thyristor-controlled power supplies and battery chargers Thyristor-controlled power supplies and battery chargers Input voltage: 115 / 230 VAC, single phase, 50 / 60 Hz or 208 / 400 / 480 VAC, three phases, 50 / 60 Hz Output voltage: 12 / 24 / 48 / 60 / 72 /

More information

CATHODIC PROTECTION TRANSFORMER RECTIFIER (CPTR)

CATHODIC PROTECTION TRANSFORMER RECTIFIER (CPTR) CATHODIC PROTECTION TRANSFORMER RECTIFIER (CPTR) Fig1. CPTR SMART CONTROL PRECISION CUSTOMIZED MANUAL OR AUTO SCR OR DIODE DRY TYPE SWITCH MODE DRY TYPE SCR OR DIODE OIL TYPE 1 INDEX PAGE 1. Cover 2. Index

More information

PRE COMMISSIONING TESTS ON EQUIPMENT AT 33/11 KV SUB STATIONS

PRE COMMISSIONING TESTS ON EQUIPMENT AT 33/11 KV SUB STATIONS PRE COMMISSIONING TESTS ON EQUIPMENT AT 33/11 KV SUB STATIONS TESTS ON TRANSFORMERS 1. IR Values a) For 33/11 KV Power Transformer 2500 V megger is to be need. b) Power Transformer neutral Earthing is

More information

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw 4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and

More information

Products and solutions for pumping, irrigation and piping

Products and solutions for pumping, irrigation and piping Products and solutions for pumping, irrigation and piping 100% electricity www.lovatoelectric.com Tra dition and Innovation LOVATO Electric S.p.A. - Bergamo - Italy Since 1922 The first LOVATO Electric

More information

Product Guide. Low voltage grounding system. Answers for industry.

Product Guide. Low voltage grounding system. Answers for industry. Product Guide Low voltage grounding system Answers for industry. Advanced switchgear solutions for process industries In today s high-tech manufacturing world, profitability can be greatly impacted by

More information

Introduction to Process Control Actuators

Introduction to Process Control Actuators 1 Introduction to Process Control Actuators Actuators are the final elements in a control system. They receive a low power command signal and energy input to amplify the command signal as appropriate to

More information

TOYOTA ELECTRONIC CONTROL TRANSMISSION

TOYOTA ELECTRONIC CONTROL TRANSMISSION Electronic Control Transmission (ECT) The Electronic Control Transmission is an automatic transmission which uses modern electronic control technologies to control the transmission. The transmission itself,

More information

12 SOLAR PHOTOVOLTAIC POWER SUPPLY SYSTEMS by John Ware. PV modules are current-limiting

12 SOLAR PHOTOVOLTAIC POWER SUPPLY SYSTEMS by John Ware. PV modules are current-limiting 12 SOLAR PHOTOVOLTAIC POWER by John Ware IT IS PLANNED for BS 7671:2008 to include a new Section 712 providing additional requirements for safety applicable to solar photovoltaic (pv) power supply systems.

More information

46120-F0 Solar Energy Training System

46120-F0 Solar Energy Training System 46120-F0 Solar Energy Training System LabVolt Series Datasheet Festo Didactic en 120 V - 60 Hz 06/2016 Table of Contents General Description 2 List of Equipment 2 List of Manuals 3 Table of Contents of

More information

WE-350 Series ¼ Turn Electric Actuator

WE-350 Series ¼ Turn Electric Actuator WE-350 Series ¼ Turn Electric Actuator Operation and Installation Manual Pg 1 (Rev. 020113) Table of Contents 1.0 General 1.1 Pre-Installation Inspection 1.2 Storage 1.3 Features & General Information

More information

Test Code: 8094 / Version 1

Test Code: 8094 / Version 1 Blueprint Electromechanical Engineering Technology PA Test Code: 8094 / Version 1 Copyright 2014. All Rights Reserved. General Assessment Information Electromechanical Engineering Technology PA Blueprint

More information

INSTALLATION MANUAL 3RP / 5RP 4-BUTTON SERIES VEHICLE SECURITY SYSTEMS

INSTALLATION MANUAL 3RP / 5RP 4-BUTTON SERIES VEHICLE SECURITY SYSTEMS 3RP / 5RP 4-BUTTON SERIES VEHICLE SECURITY SYSTEMS INSTALLATION MANUAL Before you begin the installation Read the INSTRUCTIONS! Always use a multi-meter when verifying vehicle wiring. Before mounting the

More information

Electrical Symbols and Line Diagrams

Electrical Symbols and Line Diagrams Electrical Symbols and Line Diagrams Chapter 3 Material taken from Chapter 3 of One-Line Diagrams One-line diagram a diagram that uses single lines and graphic symbols to indicate the path and components

More information

CENTERLINE Motor Control Centers Bulletin 2100 Smoke Detector Unit

CENTERLINE Motor Control Centers Bulletin 2100 Smoke Detector Unit Instructions CENTERLINE Motor Control Centers Bulletin 2100 Smoke Detector Unit Catalog Number 2100-SD1 Description The Bulletin 2100 smoke detector unit is a 0.5 space factor unit for use in Bulletin

More information

1R / 4-BUTTON SERIES

1R / 4-BUTTON SERIES Button 1 1R / 4-BUTTON SERIES VEHICLE SECURITY SYSTEM Standard Features: Two 4-Button Remote Transmitters Status indicator (LED) Valet / override switch Multi-tone siren Dual stage impact detector Remote

More information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC

More information

Circuit Breakers. NRC Series. NRC Series. 900 www.idec.com

Circuit Breakers. NRC Series. NRC Series. 900 www.idec.com Switches & Pilot Lights Display Lights NRC series circuit breakers offer circuit protection which is far superior to using fuses in applications containing relay circuits, motor circuits, heater circuits,

More information

GenTech Practice Questions

GenTech Practice Questions GenTech Practice Questions Basic Electronics Test: This test will assess your knowledge of and ability to apply the principles of Basic Electronics. This test is comprised of 90 questions in the following

More information

ASSEMBLED SOCKET-COMBINATIONS

ASSEMBLED SOCKET-COMBINATIONS ASSEMBLED SOCKETCOMBINATIONS Enclosure extra strong, schockresistant easily open, it provides a comfortable mount it can be connected across a cable gland it consists of a 35 mm mounting rail Window 6

More information

Wiring diagrams 14 1. Component key for wiring diagrams 1 to 29 Note: Not all the items listed will be fitted to all models

Wiring diagrams 14 1. Component key for wiring diagrams 1 to 29 Note: Not all the items listed will be fitted to all models Wiring diagrams 14 1 Component key for wiring diagrams 1 to 29 Note: Not all the items listed will be fitted to all models No Description 00200 Alternator with built-in regulator 00500 Battery 01001 Starter

More information

SHIFT INTERLOCK SYSTEM SHIFT INTERLOCK SYSTEM

SHIFT INTERLOCK SYSTEM SHIFT INTERLOCK SYSTEM SHIFT INTERLOCK SYSTEM The shift lock system is designed to ensure the proper operation of the automatic transmission. The driver must depress the brake pedal in order to move the gear selector from Park

More information

CHAPTER 11: Flip Flops

CHAPTER 11: Flip Flops CHAPTER 11: Flip Flops In this chapter, you will be building the part of the circuit that controls the command sequencing. The required circuit must operate the counter and the memory chip. When the teach

More information

Comparison of NEMA and IEC schematic diagrams

Comparison of NEMA and IEC schematic diagrams Cross-Reference MZ081001EN Comparison of NEMA and IEC schematic diagrams General With the increasing emphasis on globalization, many industries are now looking to all parts of the world to produce, market,

More information

EET272 Worksheet Week 9

EET272 Worksheet Week 9 EET272 Worksheet Week 9 answer questions 1-5 in preparation for discussion for the quiz on Monday. Finish the rest of the questions for discussion in class on Wednesday. Question 1 Questions AC s are becoming

More information

Generator Stator Protection, under/over voltage, under /over frequency and unbalanced loading. Ramandeep Kaur Aujla S.NO 250447392

Generator Stator Protection, under/over voltage, under /over frequency and unbalanced loading. Ramandeep Kaur Aujla S.NO 250447392 1 Generator Stator Protection, under/over voltage, under /over frequency and unbalanced loading By Ramandeep Kaur Aujla S.NO 250447392 ES 586b: Theory and applications of protective relays Department of

More information

UNDERSTANDING AND CONTROLLING COMMON-MODE EMISSIONS IN HIGH-POWER ELECTRONICS

UNDERSTANDING AND CONTROLLING COMMON-MODE EMISSIONS IN HIGH-POWER ELECTRONICS Page 1 UNDERSTANDING AND CONTROLLING COMMON-MODE EMISSIONS IN HIGH-POWER ELECTRONICS By Henry Ott Consultants Livingston, NJ 07039 (973) 992-1793 www.hottconsultants.com hott@ieee.org Page 2 THE BASIC

More information

26 3213.13 Diesel Engine Driven Generators Page 1 of 6

26 3213.13 Diesel Engine Driven Generators Page 1 of 6 Last Update: December 8, 2014 A. Description of System Consultant s Handbook Page 1 of 6 1. Provide a diesel engine driven electric generating unit, factory assembled, tested and certified to operate at

More information

GROUND DETECTION CIRCUITS FOR STATIONARY APPLICATIONS (IN PLAIN DOWN TO EARTH LANGUAGE)

GROUND DETECTION CIRCUITS FOR STATIONARY APPLICATIONS (IN PLAIN DOWN TO EARTH LANGUAGE) GROUND DETECTION CIRCUITS FOR STATIONARY APPLICATIONS (IN PLAIN DOWN TO EARTH LANGUAGE) Matthew Theriault Designer Hindle Power Inc. Easton, PA SCOPE AND PURPOSE OF THE PAPER Why do we bother to monitor

More information

7. Reactive energy compensation

7. Reactive energy compensation 593 7. Reactive energy compensation 594 7. REACTIVE ENERGY COMPENSATION Reactive energy compensation is an important element for reducing the electricity bill and improving the quality of the electrical

More information

The Basics of Digital Multimeters

The Basics of Digital Multimeters IDEAL INDUSTRIES INC. The Basics of Digital Multimeters A guide to help you understand the basic Features and Functions of a Digital Multimeter. Author: Patrick C Elliott Field Sales Engineer IDEAL Industries,

More information

Security and Remote Start Installation Guide for models: CA 6150 CA 6550

Security and Remote Start Installation Guide for models: CA 6150 CA 6550 PROFESSIONAL SERIES Security and Remote Start Installation Guide for models: CA 6150 CA 6550 2009 Audiovox Electronics Corporation. All rights reserved. 1 Table of Contents Before You Begin... 4 Wire Connection

More information

OVERCURRENT & EARTH FAULT RELAYS. To study the protection of equipment and system by relays in conjunction with switchgear.

OVERCURRENT & EARTH FAULT RELAYS. To study the protection of equipment and system by relays in conjunction with switchgear. OVERCURRENT & EARTH FAULT RELAYS Objective: To study the protection of equipment and system by relays in conjunction with switchgear. Theory: The function of a relay is to detect abnormal conditions in

More information

1. The diagram below represents magnetic lines of force within a region of space.

1. The diagram below represents magnetic lines of force within a region of space. 1. The diagram below represents magnetic lines of force within a region of space. 4. In which diagram below is the magnetic flux density at point P greatest? (1) (3) (2) (4) The magnetic field is strongest

More information

Oil and Coolant Circulating Heating System. Model - OCSM

Oil and Coolant Circulating Heating System. Model - OCSM Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine

More information

ELECTRICAL WIRING (R.H. DRIVE VEHICLES)

ELECTRICAL WIRING (R.H. DRIVE VEHICLES) C-1 ELECTRICAL WIRING (R.H. DRIVE VEHICLES) CONTENTS GENERAL.......................... 3 WIRING HARNESS CONFIGURATION DIAGRAMS......................... 4 ENGINE COMPARTMENT................ 4 DASH PANEL...........................

More information

understanding medium frequency induction melting furnace and its components

understanding medium frequency induction melting furnace and its components understanding medium frequency induction melting furnace and its components 9 Spruce Street, Jersey City, NJ 07306 USA sales@electroheatinduction.com INDUCTION MELTING FURNACE AND ITS COMPONENTS The purpose

More information

Fundamentals of Power

Fundamentals of Power Fundamentals of Power Fundamentals of Power 2008 American Power Conversion Corporation. All rights reserved. All trademarks provided are the property of their respective owners. Learning Objectives At

More information

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A AUTOMATIC TRANSFER SWITCH Changeover Type from 250A to 2500A Table of Contents Preamble 1.1 Theoretical base 1.2 Selection the size of automatic transfer switch 1.3 Automatic transfer switch components

More information

15 Series - Electronic step relay and dimmer. Features 15.91 15.51 15.81 SERIE

15 Series - Electronic step relay and dimmer. Features 15.91 15.51 15.81 SERIE Series - Electronic step relay and dimmer SERIE Features.91.51.81 Electronic step relay and dimmer for control of lighting levels Suitable for incandescent and halogen lighting loads (with or without transformer

More information

6.0 Electrical Installations

6.0 Electrical Installations 6.0 An electrical installation is a combination of electrical equipment installed to fulfill a specific purpose and having coordinated characteristics. In dealing with the electrical installation, it is

More information

The full wave rectifier consists of two diodes and a resister as shown in Figure

The full wave rectifier consists of two diodes and a resister as shown in Figure The Full-Wave Rectifier The full wave rectifier consists of two diodes and a resister as shown in Figure The transformer has a centre-tapped secondary winding. This secondary winding has a lead attached

More information

What Is Regeneration?

What Is Regeneration? What Is Regeneration? Braking / Regeneration Manual Regeneration Overview Revision 1.0 When the rotor of an induction motor turns slower than the speed set by the applied frequency, the motor is transforming

More information

ELECTRICIAN TRADE REGULATION

ELECTRICIAN TRADE REGULATION Province of Alberta APPRENTICESHIP AND INDUSTRY TRAINING ACT ELECTRICIAN TRADE REGULATION Alberta Regulation 274/2000 With amendments up to and including Alberta Regulation 122/2014 Office Consolidation

More information

REPORT ON CANDIDATES WORK IN THE CARIBBEAN ADVANCED PROFICIENCY EXAMINATION MAY/JUNE 2008 ELECTRICAL AND ELECTRONIC TECHNOLOGY (TRINIDAD AND TOBAGO)

REPORT ON CANDIDATES WORK IN THE CARIBBEAN ADVANCED PROFICIENCY EXAMINATION MAY/JUNE 2008 ELECTRICAL AND ELECTRONIC TECHNOLOGY (TRINIDAD AND TOBAGO) CARIBBEAN EXAMINATIONS COUNCIL REPORT ON CANDIDATES WORK IN THE CARIBBEAN ADVANCED PROFICIENCY EXAMINATION MAY/JUNE 2008 ELECTRICAL AND ELECTRONIC TECHNOLOGY (TRINIDAD AND TOBAGO) Copyright 2008 Caribbean

More information

Trade of Electrician. Three-phase Distribution Boards And Socket Circuits

Trade of Electrician. Three-phase Distribution Boards And Socket Circuits Trade of Electrician Standards Based Apprenticeship Three-phase Distribution Boards And Socket Circuits Phase 2 Module No. 2.3 Unit No. 2.3.2 COURSE NOTES Created by Charlie Walsh - Athlone TC Revision

More information

ABB ! CAUTION. Type COQ Negative Sequence Generator Relay. (50/60 Hertz) 41-161J. Instruction Leaflet

ABB ! CAUTION. Type COQ Negative Sequence Generator Relay. (50/60 Hertz) 41-161J. Instruction Leaflet ABB Instruction Leaflet 41-161J Effective: May 1997 Supersedes I.L. 41-161H Dated July 1984 ( ) Denotes Change Since Previous Issue Type COQ Negative Sequence Generator Relay (50/60 Hertz)! CAUTION Before

More information

GLOLAB Two Wire Stepper Motor Positioner

GLOLAB Two Wire Stepper Motor Positioner Introduction A simple and inexpensive way to remotely rotate a display or object is with a positioner that uses a stepper motor to rotate it. The motor is driven by a circuit mounted near the motor and

More information

Occupational Profile: Electrical & Electronics Engineering Technician

Occupational Profile: Electrical & Electronics Engineering Technician Occupational Profile: Electrical & Electronics Engineering Technician A competent Electrical & Electronics Engineering Technician should be able to demonstrate the following skills and competences: 1.

More information

FEDERAL ELECTRICITY & WATER AUTHORITY

FEDERAL ELECTRICITY & WATER AUTHORITY UNITED ARAB EMIRATES FEDERAL ELECTRICITY & WATER AUTHORITY SPECIFICATION FOR 433 VOLTS SWITCHGEARS (LVAC BOARD) LVAC SWITCHBOARDS I N D E X CLAUSE TITLE 1. GENERAL 2. TEMPERATURE RISE 3. BUSBARS 4. CONSTRUCTION

More information

Comprehensive Range of Industrial Products and Solutions

Comprehensive Range of Industrial Products and Solutions Comprehensive Range of Industrial Products and Solutions SAFETY AUTOMATION Micro Controllers Small Controllers Mid Range Controllers Large Automation Controllers Safety Programmable Controller Motion Controller

More information

Certification Awarded to ABB LTDA. AV. DOS AUTONOMISTAS, 1496, VILA CAMPESINA, 06020-902 - OSASCO/SP BRAZIL

Certification Awarded to ABB LTDA. AV. DOS AUTONOMISTAS, 1496, VILA CAMPESINA, 06020-902 - OSASCO/SP BRAZIL Certification Bureau Veritas Certification certifies that the Management System of the above organization has been assessed and found to be in accordance with the requirements of the standard detailed

More information

INSTALLATION & SERVICE MANUAL. Display Panel

INSTALLATION & SERVICE MANUAL. Display Panel INSTALLATION & SERVICE MANUAL Display Panel The PowerLine EMS TM is a specialized power distribution and energy management system intended to be used in recreational vehicles. The Control Module is housed

More information

GUIDE TO THE AM2 EXAM

GUIDE TO THE AM2 EXAM AM2 GUIDE TO THE AM2 EXAM What is AM2? AM2 or the Achievement Measurement 2 is a practical performance skill test administered by the National Electrotechnical Training (NET). You must take the AM2 test

More information

Power measurement in balanced 3 phase circuits and power factor improvement. 1 Power in Single Phase Circuits. Experiment no 1

Power measurement in balanced 3 phase circuits and power factor improvement. 1 Power in Single Phase Circuits. Experiment no 1 Experiment no 1 Power measurement in balanced 3 phase circuits and power factor improvement 1 Power in Single Phase Circuits Let v = m cos(ωt) = cos(ωt) is the voltage applied to a R-L circuit and i =

More information

TROUBLESHOOTING PRELIMINARY

TROUBLESHOOTING PRELIMINARY TROUBLESHOOTING PRELIMINARY To troubleshoot, one must first have a working knowledge of the individual parts and their relation to one another. Must have adequate hand tools Must have basic instrumentation:

More information

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw ,1'8675,$/#*(16(7 6HULHV#'9#448 32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw Generator set consisting of engine and alternator mounted

More information

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches PART 1 GENERAL 1.01 Scope Optional Standby Power Generator Systems A. Furnish and install automatic transfer switches

More information

Short Range Wireless Switch System Handheld 8 Installation and Operations Guide

Short Range Wireless Switch System Handheld 8 Installation and Operations Guide Phone: (866) 701-1146 Fax: (425) 216-7558 www.remotecontroltech.com Short Range Wireless Switch System Handheld 8 Installation and Operations Guide Introduction... 2 Before Installation... 2 Receiver Installation...

More information

CONTINUOUSLY VARIABLE TRANSMISSION (CVT)

CONTINUOUSLY VARIABLE TRANSMISSION (CVT) GROUP 23 CONTINUOUSLY VARIABLE TRANSMISSION (CVT) CONTENTS CVT........................... 23-2 GENERAL INFORMATION............. 23-2 ELECTRONIC CONTROL SYSTEM...... 23-3 EEPROM...........................

More information

Power Supplies. 1.0 Power Supply Basics. www.learnabout-electronics.org. Module

Power Supplies. 1.0 Power Supply Basics. www.learnabout-electronics.org. Module Module 1 www.learnabout-electronics.org Power Supplies 1.0 Power Supply Basics What you ll learn in Module 1 Section 1.0 Power Supply Basics. Basic functions of a power supply. Safety aspects of working

More information

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE DESCRIPTION MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE DESCRIPTION The SST Model 5010 Two Channel Smoke/Fire Detection Module provides two independent detection input channels for the NOVA-5000

More information

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual

More information

Line Reactors and AC Drives

Line Reactors and AC Drives Line Reactors and AC Drives Rockwell Automation Mequon Wisconsin Quite often, line and load reactors are installed on AC drives without a solid understanding of why or what the positive and negative consequences

More information

Eaton s E-Series protective relay family

Eaton s E-Series protective relay family E-Series protective relays Feeder distribution relays Motor relays Transformer relays Generator relays Eaton s E-Series protective relay family Microprocessor-based design Eaton s E-Series relay family

More information

Diode Applications. by Kenneth A. Kuhn Sept. 1, 2008. This note illustrates some common applications of diodes.

Diode Applications. by Kenneth A. Kuhn Sept. 1, 2008. This note illustrates some common applications of diodes. by Kenneth A. Kuhn Sept. 1, 2008 This note illustrates some common applications of diodes. Power supply applications A common application for diodes is converting AC to DC. Although half-wave rectification

More information

What are the basic electrical safety issues and remedies in solar photovoltaic installations?

What are the basic electrical safety issues and remedies in solar photovoltaic installations? What are the basic electrical safety issues and remedies in solar photovoltaic installations? Presented by: Behzad Eghtesady City of Los Angeles Department of Building and Safety Topics Covered Photovoltaic

More information

Essential Electrical Concepts

Essential Electrical Concepts Essential Electrical Concepts Introduction Modern vehicles incorporate many electrical and electronic components and systems: Audio Lights Navigation Engine control Transmission control Braking and traction

More information

Drayton Digistat +2RF/+3RF

Drayton Digistat +2RF/+3RF /+3RF Programmable Room Thermostat Wireless Model: RF700/22090 Model: RF701/22092 Power Supply: Battery - Thermostat Mains - Digistat SCR Invensys Controls Europe Customer Service Tel: 0845 130 5522 Customer

More information

User Guide. Model 380260 Insulation Tester / Megohmmeter

User Guide. Model 380260 Insulation Tester / Megohmmeter User Guide Model 380260 Insulation Tester / Megohmmeter Introduction Congratulations on your purchase of Extech s Insulation Tester/Megohmmeter. The Model 380260 provides three test ranges plus continuity

More information

Unified requirements for systems with voltages above 1 kv up to 15 kv

Unified requirements for systems with voltages above 1 kv up to 15 kv (1991) (Rev.1 May 2001) (Rev.2 July 2003) (Rev.3 Feb 2015) Unified requirements for systems with voltages above 1 kv up to 15 kv 1. General 1.1 Field of application The following requirements apply to

More information

GENERATOR START CONTROL MODULE - MINI (2 Wire to 3 Wire)

GENERATOR START CONTROL MODULE - MINI (2 Wire to 3 Wire) FEATURES & APPLICATIONS Inexpensive 2 wire to 3 wire start controller for electric start high speed gas generators. Optimized for use with Outback Invertors. Supports three types of 3 wire generator control

More information

BREEAM CRITERIA WATER LEAK DETECTION SYSTEM Type WG2 - CONTROL PANEL CONNECTIONS

BREEAM CRITERIA WATER LEAK DETECTION SYSTEM Type WG2 - CONTROL PANEL CONNECTIONS BREEAM CRITERIA WATER LEAK DETECTION SYSTEM Type WG2 - CONTROL PANEL CONNECTIONS WG2 Dimensions: LxHXW: 26 x 14.5 x 29.5 cm INTERNAL Alarm Terminals EXTERNAL Alarm Terminals WG2 Control Unit WaterGuard

More information

Electrical Grounding. Appendix C

Electrical Grounding. Appendix C Appendix C Electrical Grounding Low-Voltage Equipment Grounding The most frequently cited Office of Safety and Health Administration (OSHA) electrical violation is improper occupational grounding of equipment

More information