R. GIACHINO, M. ALBERT LHC MACHINE CHECKOUT 2015
|
|
- Moses Owen
- 8 years ago
- Views:
Transcription
1 R. GIACHINO, M. ALBERT LHC MACHINE CHECKOUT 2015
2 QUENCH 2
3 SATURDAY PNO.b3 in RQD.A45 and RQF.A45 Tripped a few minutes after flattop 3
4 SATURDAY RQF.A12 tripped at while at nominal. Earth fault still present RQ9.L2 : QPS not OK Quench heaters discharged Piquet intervention OK RB/RQD/RQF in 45 reached the flat top. 4
5 SATURDAY RB.A78 tripped while going to standby. PC trip at 17: signal I_EARTH_PCNT = -109% disappeared after. 5
6 SATURDAY - COLLIMATORS Test of collimator sequences TCDQ B1 / B2 PROFILE_OUT_OF_ENERGY ERROR position is within limits but error cannot be reset PRSStatus FAULTY - unable to reset it Energy limit: 45mm Collimator position: 15mm Ramp & SQUEEZE of collimators movement + sequences OK 6
7 SATURDAY - COLLIMATORS Collimator MP tests of limit functions successful all collimators ARMED with RAMP functions (except TCDQ) TCDQ has interlock due to wrong energy value PRS moves but MDC not all OK MDC moves with functions and PRS is not started: collimators correctly stopped all OK 7
8 SATURDAY pre-cycle S23, 56, 67, 81 RAMP/SQUEEZE/RAMPDOWN of S23, S56, S67, S81 RSD2.A67B1 tripped at end of ramp down. Looks like quench due to zero voltage crossing. RSD1.A67B1 and RSF2.A67B1 subsequently trip 8
9 SUNDAY PGC1.1 on ARC45 RCO.A45B1/2 RCD.A45B1/2 RCS.A45B1 FT 9
10 POWERING GROUPS OF CIRCUITS 10
11 SUNDAY REMAINING HWC TESTS PGC1.1 on ARC45 done but trips of: RCO.A45B1/2, RCD.A45B1/2, FT 11
12 SATURDAY PC s issues: RQF.A12. ELQA done nothing found. Trip at nominal no quench Earth fault >> EPC Piquet Intervention Nothing found on the converter side. RQT13.R1B1 tripped S12 (not powered since) RQD.A45 and RQF.A45 Tripped a few minutes after flattop >> Reset OK RSD2.A67B1 RSD1.A67B1 RSF2.A67B1 tripped at end of ramp down RB.A78 tripped while going to standby from FT Earth Fault disappeared after 15 mins. RCO/RCD.A78B1 trip at the end of the ramp!!! 5 th time Three quenches in a shift... 12
13 WEDNESDAY PC s issues: RQF.A12. ELQA done nothing found. Trip at nominal no quench Earth fault >> EPC Piquet Intervention Nothing found on the converter side. Standard procedure in case of an earth fault is to perform HV qualification by ELQA. From the voltage feelers it seems that the earth fault is in the warm part so I would suggest that ELQA goes in on monday. Also better to first perform some simulations (Emmanuele, Monday) before we power the circuit again. Arjan 13
14 WEDNESDAY PC s issues: RB.A78 tripped while going to standby from FT Earth Fault disappeared after 15 mins. 14
15 RB.A78 I_MEAS and I_EARTH_PCNT Ground fault, fuse gone (1A or 100mA?) ~17:57 No fault anymore? Or next fuse? 15
16 RB.A78 nqps DS: U_DIODE signals 16
17 RB.A78 nqps: Voltage feelers (1) 17
18 RB.A78 nqps: Voltage feelers (2) 18
19 RB.A78 nqps: Voltage feelers (3) 19
20 SATURDAY Ramp of RCO.A78B1 to 105A and RCD.A78.B1 to -560A => Tripped after 55min Later both circuits tripped again after almost 1 h at high current 20
21 INVESTIGATION ON RB.A34 FAULT TO GROUND Investigation continued Precise fault localization through electrical measurements performed in the tunnel by ElQA team (including reflectometry) X-ray imaging to localize precisely the short Many Lab tests to simulate the behaviour of the short in a configuration as close as possible to the one of the tunnel Several possible solutions investigated and risk analysis assessed Cryogenic investigation to try a local displacement Local heating of the diode via injection of small current Local (global) warm-up. Injection appropriate current through the fault to try moving/eliminating it A19L C19L4 21
22 INVESTIGATION ON RB.A34 FAULT TO GROUND Investigation continued Summary: the power part of the system to burn the debris is working correctly, the DAQ electronics is working correctly, but only at low range the capacitor bank charging voltages, for high charging voltages the recorded signals are unphysical and not easy to interpret. Rescheduled not before Monday A19L C19L4 22
23 ACCESS REQUESTS WHO WHERE WHEN WHAT Duration RF UX45 RF setting-up BIS IR3 & 4 Back to nominal 3 hrs. BIS Ua63& 67 28/3 Bis team 3 hrs EN/MME Point 4 Xray Material 2 hrs. Alice 28/3 8 hrs. ELQA Point 4 Earth fault intervention 23
24 WEEK-END PLAN Preparation for RB.A34 earth fault test >> Monday Priority to PGC s RB.A45 and all the remaining circuits. Full Operational machine cycle tests BIS interlock tests Nominal sequence tests Precycle, ramp and squeeze in all possible sectors RF tests Collimator tests LHC and experiments mostly closed during week end 24
25 OPERATIONAL CYLE Nominal sequence : signature missing for CHECK MKD MCS SETTINGS SET BETS READTABLES TRUE failed: ABT is working on it HW/database mismatch for ABORTGAP CLEAN parameters BPM calibration failed : host not reachable >>BI informed BCT OFFSET correction failed because system B not OK DC BCT calibration finished. Overall result: SUCCESS BLM MCS checks failing for2 card only BLM sanity check and MCS ok now Issue when loading the TCDQ B2 Injection Protection collimators: machine protection tests on-going 25
26 BEAM INSTRUMENTATION BLM system operational BLM BIS user permit should be enabled BLM MCS and SANITY CHECKS finished BLM team need more tests. New thresholds and monitor factor uploaded tests ongoing Wirescanners Operational BI/OP tests RBAC problem for BCT, BLM Tasks updating with the 2 new crates (Laurette), BPM calibration failed device not accessible RING DC-BCT calibration task not working >> Done 26
27 THURSDAY NIGHT Collimators B1 and B2 Collimators have been sent to parking B1&B2 colls at injection settings Collimators ARMED RAMP functions except TCDQ More tests continue TCDQ B1 / B2 PROFILE_OUT_OF_ENERGY ERROR TCDQ B1 / B2 PROFILE_OUT_OF_ENERGY ERROR TCDQA.A4R6.B1 failed in inj. Settings The position is within limits reset does not work! 27
28 WEDNESDAY Cryogenic status: OK S34 at 3.2 K 28
29 A19L C19L4 29
30 SATURDAY Continuation of HWC tests on main circuits in S45 (PNO.a6) RAMP & SQUEEZE of sectors 23, 56, 67, 78, 81 Trip of RQ9.L2 (QPS problem, fixed after P2) RB.A78 17:39 while going to STANDBY. Earth Fault disappeared after 20 min. RB, RQD, RQF in 45 to IPNO + 100A for 2h after PNO.a6 30
31 SATURDAY - COLLIMATORS Test of collimator sequences TCDQ B1 / B2 PROFILE_OUT_OF_ENERGY ERROR position is within limits but error cannot be reset PRSStatus FAULTY - unable to reset it Energy limit: 45mm Collimator position: 15mm Ramp & SQUEEZE of collimators movement + sequences OK 31
32 SATURDAY - COLLIMATORS Collimator MP tests of limit functions successful all collimators ARMED with RAMP functions (except TCDQ) TCDQ has interlock due to wrong energy value PRS moves but MDC not all OK MDC moves with functions and PRS is not started: collimators correctly stopped all OK 32
33 S 12 QF.A12 trip (Wednesday) 33
34 WEDNESDAY S 12 QF.A12 trip (Saturday) 34
35 REMAINING ISSUES Vacuum valve MSI-TI2 (VVGS.29528) interlock SPS EXT1 master BIC to be tested extraction conditions established >> Markus - BIC LHC probe beam re-phasing issues, stability issues => often BQM interlocks Threshold increased, to be checked with beam BTVDD image orientation > on hold until LBDS experts decide on preference BI-ABT decision to be made >> Jan -BI Controls: CMW/RDA issue affecting several clients new libraries released CIBDS problem while arming LBDS > Bruno, ongoing LBDS-XPOC: Missing BI data: (BCTFR, BSRA, etc..) >> Nicolas M- BI 35
36 TEST TO BE DONE BIS LOOP CLOSED Vacuum valves test with BIS loop closed LBDS BETS with 45 finished Circulate and Dump 36
37 FRIDAY Access in the morning Deployment & restart of LHC-SIS (new MKI FESA classes) Trimming of the RF voltage OK RCO.A78B1 to +105 A RCD.A78B1 to -560 A -> quenched at about -545 A RCO.A78B1 RCD.A78B1 37
38 FRIDAY Collimator MPS tests IP7: software & hardware reboot on TCSG.A4L7.B2 OK IP3: software & hardware reboot on TCSG.4R3.B1 - OK Test LOCAL MODE all OK ADT-FGC configuration updated => loading settings for injection OK FPA in RB.A78 at 2 ka LHC SEQ: BLM MCS and SANITY CHECKS OK PGCs on XR5 and XL1 Manual ramps on RQT12, RQT13, RQTL11 Again trip of RCO/RCD.A78B1 during the ramp 38
39 POWERING GROUPS OF CIRCUITS GPM OK RCD+RCO PGC1.1 PGC1.2 PGC1.3 PGC1.4 PGC1.5 PGC1.6 COMPLETED ARC12 Yes 17/02-19:25 20/02-20:41 13/03-00:45 13/03-17:12 LR1 Yes 24/02-13:09 04/03-23:01 ML2 Yes 03/03-17:57 04/03-23:58 IT.R1 Yes 23/03-23:42 16/03-21:06 IT.L2 Yes 17/03-00:01 17/03-06:11 ARC23 Yes 10/03-22:19 13/03-18:00 14/03-13:19 16/03-22:30 MR2 Yes 03/03-18:08 10/03-16:39 IT.R2 Yes 23/03-21:55 16/03-21:43 ARC34 ML4 Yes 22/03-12:03 22/03-23:52 ARC45 MR4 Yes 15/03-01:44 15/03-19:37 LL5 Yes 14/03-00:02 15/03-18:54 IT.L5 Yes 23/03-23:43 17/03-00:28 ARC56 Yes 14/03-04:19 14/03-14:46 16/03-01:33 17/03-01:32 LR5 Yes 14/03-00:17 15/03-19:14 ML6 Yes 03/03-18:38 06/03-00:16 IT.R5 Yes 23/03-23:45 24/03-03:09 ARC67 Yes 14/02-08:40 11/03-00:31 12/03-14:17 13/03-18:30 MR6 Yes 20/02-21:01 05/03-02:33 ARC78 Yes 21/03-14:10 21/03-17:33 22/03-19:43 23/03-20:00 ML8 Yes 03/03-18:15 11/03-02:38 IT.L8 Yes 23/03-19:18 24/03-00:27 ARC81 Yes 13/03-17:52 14/03-13:10 17/03-03:26 17/03-05:40 MR8 Yes 03/03-18:28 11/03-01:58 LL1 Yes 13/03-21:14 15/03-19:20 IT.R8 Yes 14/03-12:45 16/03-20:59 IT.L1 Yes 24/03-15:54 21/03-02:38 Cryo tuning to be improved 39
40 JPhT Credits to EN-MME Big thanks to A Piguiet,JM Dalin, G Arnau, A Porret For flexibility, reactivity, quality of the work RADIOS FROM TOP C19L4 BEFORE
41 41
42 Resolution : < 0.5 mm 42
43 43
44 44
45 FROM A CLOSED INTERCONNECTION, BEST ANGLES TO RADIOGRAPHY THE HALF MOON OF THE DIODES Axe2 Axe1 45
46 46
47 47
48 48
49 49
LHC MACHINE PROTECTION
LHC MACHINE PROTECTION Rossano Giachino, CERN, Geneva, Switzerland Abstract The energy stored in LHC magnets presents a considerable challenge for commissioning even before any beam is injected. Furthermore,
More informationMachine Interlocks Systems
rlocks Status for locks s Hardware readiness and plans State of the supervision Bruno Puccio Pierre Dahlen Benjamin Todd Markus Zerlauth 1 Outline locks = 5 systems managed by AB/CO Hardware readiness
More informationThe commissioning of the LHC: first the technical systems, then the commissioning with beam
The commissioning of the LHC: first the technical systems, then the commissioning with beam Roberto Saban 4. Ulusal Parçacık Hızlandırıcıları ve Uygulamaları Kongresi 30 Ağustos 1 Eylül 2010, Bodrum -
More informationStatus of the Diamond Storage Ring RF Systems. Morten Jensen on behalf of Diamond Storage Ring RF Group
Status of the Diamond Storage Ring RF Systems Morten Jensen on behalf of Diamond Storage Ring RF Group Content 1. General Operational Status 2. Main issues and causes of trips 3. 200 ma + operation Qext
More informationRunning in 2011 - Luminosity. Mike Lamont Verena Kain
Running in 2011 - Luminosity Mike Lamont Verena Kain Presentations Many thanks to all the speakers! Experiments expectations Massi Ferro-Luzzi Pushing the limits: beam Elias Métral Pushing the limits:
More informationTE-MPE on-call service for the LHC
TE-MPE on-call service for the LHC Team members On call members Experts Mandate Giorgio D Angelo on behalf of TE-MPE On call team, with inputs from R. Denz Description of the TE-MPE on-call Service Organization
More informationController Automation, Model II+
Controller Automation Page 2 of 2 Automation with the RADAK II+ power controller II+ I/O Points: Inputs 5 Programmable Digital inputs 2 Dedicated digital inputs (Channel select and External SCR control
More informationconventional system operation
conventional system operation detection line operation Conventional detection systems normally operate on a 24VDC line. In the standby condition, the detectors will draw a low current, typically less than
More informationOutline. MCSA: Server Virtualization
MCSA: Server Virtualization Description Get hands-on instruction and practice implementing Microsoft Server Virtualization with Windows Server 2012 R2 Hyper-V and System Center 2012 R2 Virtual Machine
More informationON-GUARD. Guard Management System. Table of contents : Introduction Page 2. Programming Guide Page 5. Frequently asked questions Page 25 - 1 -
ON-GUARD Guard Management System Table of contents : Introduction Page 2 Programming Guide Page 5 Frequently asked questions Page 25-1 - Introduction On Guard tm is designed to exceed all the requirements
More informationZero Degree Extraction using an Electrostatic Separator
Zero Degree Extraction using an Electrostatic Separator L. Keller Aug. 2005 Take another look at using an electrostatic separator and a weak dipole to allow a zero degree crossing angle a la the TESLA
More informationTECHNICAL SERVICE DEPARTMENT Technical Service Bulletin 1-800-432-8373. Tankless Electric (RTE) Troubleshooting
Sequence of Operations 1 Power supply and field wiring block 2 Energy Cut Off (ECO) 3 Water flow plunger and cold inlet 4 Magnetic flow switch 5 Water temperature thermistor 6 Control panel and circuit
More informationFCC 1309180800 JGU WBS_v0034.xlsm
1 Accelerators 1.1 Hadron injectors 1.1.1 Overall design parameters 1.1.1.1 Performance and gap of existing injector chain 1.1.1.2 Performance and gap of existing injector chain 1.1.1.3 Baseline parameters
More informationMATCHDAY 1 7-9 September 2014
MATCHDAY 1 7-9 September 2014 7 September Sunday 18:00 Group D 7 September Sunday 20:45 Group D 7 September Sunday 20:45 Group D 7 September Sunday 18:00 Group F 7 September Sunday 20:45 Group F 7 September
More informationTabella delle variabili in supervisione UAMZ 1.1 28/10/09
TYPE ADDRESS READ/WRITE DESCRIPTION D 90 R EXTERNAL FLUSSOSTAT SIGNAL D 91 R STATUS DIGITAL OUTPUT 1 ELETRIC VALVE SPAY 1 D 92 R STATUS DIGITAL OUTPUT 4 ELETRIC VALVE SPAY 2 D 93 R STATUS DIGITAL OUTPUT
More informationEvent recording (or logging) with a Fluke 287/289 Digital Multimeter
Event recording (or logging) with a Fluke 287/289 Digital Multimeter Our thanks to Fluke Corp for allowing us to reprint the following article. One of the major features of the Fluke 280 Series digital
More informationAcademic Calendar for Faculty
Summer 2013 Term June 3, 2013 (Monday) June 3-4, 2013 (Monday Tuesday) June 5, 2013 (Wednesday) June 5-6, 2013 (Wednesday Thursday) June 6, 2013 (Thursday) July 3, 2013 (Wednesday) July 4, 2013 (Thursday)
More informationAutomation System TROVIS 6400 TROVIS 6493 Compact Controller
Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general
More informationTest & Data Management Software
Test & Data Management Software TDMS protective relays energy meters transducers power quality CT-VT-PT transformers ground grid circuit breakers batteries surge arresters The Integrated Testing Solution
More informationDyeing Programmer DP - 01
Dyeing Programmer DP - 01 Display and Controls. 1) Display: 16/2 alphanumeric display 2) Temperature range: 0 to 150 degree. 3) Resolution: 1 degree. 4) Accuracy: +/- 1 degree. 5) Temperature control setting:
More informationMinimum requirements for the 13 ka splices for 7 TeV operation
Minimum requirements for the 13 ka splices for 7 TeV operation - type of defects - FRESCA tests and validation of the code QP3 - a few words on the RRR - I safe vs R addit plots - conclusion Arjan Verweij
More informationHIGH CURRENT OPERATION OF THE ACSI TR30 CYCLOTRON
HIGH CURRENT OPERATION OF THE ACSI TR30 CYCLOTRON 18 th International Conference on Cyclotrons and their Applications, Sicily, 2007 Vasile Sabaiduc, Project Manager, RF Senior Engineer Advanced Cyclotron
More informationtalento dialog Switching programs compiling editing transferring WA-Ekf 3893/06.99/S:MMS/D:Kohl/80.10.0938.7
talento dialog Switching programs compiling editing transferring WA-Ekf 3893/06.99/S:MMS/D:Kohl/80.10.0938.7 Contents I Before starting..................................... 2 Installation/Deinstallation......................
More informationEvent recording (or logging) with a Fluke 287/289 Digital Multimeter
Event recording (or logging) with a Fluke 287/289 Digital Multimeter Application Note One of the major features of the Fluke 280 Series digital multimeters (DMM) with TrendCapture is their ability to record
More information4 Alarm and info. Alarm. Yes Warning. No Information No Reset alarms > No Current list > Alarm log list > Delete alarm log > No
6. 6.1 and info (Menu 4) NB are shown in the event of unit faults or irregular operation Check the Current list (Menu 4) for alarm messages and refer to the list of alarms given at the end of these instructions.
More informationWireless Data Logger Monitoring Systems
Wireless Data Logger Monitoring Systems Table of Contents About MadgeTech, Inc. Wireless Systems & Components Wireless Data Loggers 2000A Wireless Data Logger Models MadgeTech Cloud Services MadgeTech
More informationRF Etch Monitor. Introduction
RF Etch Monitor Introduction A newly designed RF Matching Controller & RF Etch Monitor replaces the old OEM design of the RF Matching Controller and the RF Etch Monitor. OEM RF Matching Controller: - Analog
More informationTDMS Test & Data Management Software
Test & Data Management Software TDMS protective relays energy meters transducers power quality CT-VT-PT transformers ground grid circuit breakers batteries surge arresters The Integrated Testing Solution
More informationDC LOAD TESTING Gian Trento June 18 th, 2004
DC LOAD TESTING Gian Trento June 18 th, 2004 THIS TECHNICAL NOTE DESCRIBES THE PROCESS OF CONNECTING THE UNIVERSAL VOLTRONICS CORPORATION (UVC) POWER SYSTEM TO THE DC LOAD AS WELL AS OPERATING THE UVC
More informationTune and Chromaticity Tracking in the Tevatron. C.Y. Tan 09 May 2006
Tune and Chromaticity Tracking in the Tevatron C.Y. Tan 09 May 2006 Overview What is the Tevatron tune tracker? Selected results from some stores. (There are many stores with TT running). Planned chromaticity
More informationTechnical Specification for the Cryogenic Testing of HTS Current Leads
Group Ref.: AT-MEL-CF EDMS No.: 44036 The Large Hadron Collider Project IT-3303/AT/LHC Technical Specification for the Cryogenic Testing of HTS Current Leads Abstract This specification concerns the testing
More informationLarge Systems Commissioning
Large Systems Commissioning, DESY CAS Vacuum in Accelerators Platja D`Aro, May 21, 2006 Special thanks to O. Gröbner 1 Outline Introduction Pump Down and Leak Check Components Check Bake Out Interlocks/Safety
More informationModel PBX 416 Plus System Administration Guide
Model PBX 416 Plus System Administration Guide Introduction 4 Installation Hints 4 System Programming 5 - System Password 5 - Changing Password 5 - Entering password in Direct 5 Dial Mode Exchange Line
More informationModel PBX 416+ Programming & User Guide
Model PBX 416+ Programming & User Guide 1 Introduction... 5 Installation hints... 5 Wall mounting... 5 System programming... 6 System password... 6 Changing the password... 6 Exchange line set up... 6
More informationHERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
More informationStandby Services or Reliance on Experts for Accelerator control?
Standby Services or Reliance on Experts for Accelerator control? Claude-Henri Sicard AB/CO ATC/ABOC Days 27 Plan: PS Complex Controls Standby service: case study Organisation Domain of intervention Statistics
More informationModel PBX816ex. Programming & User Guide
Model PBX816ex Programming & User Guide 1 Introduction... 5 Installation hints... 5 Expanding Your System 5 System programming... 6 System password... 6 Changing the password... 6 Exchange line set up...
More informationLG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units
Multi Split Units If there is a fault on any LG Multi unit, an Error mark is indicated on the display window of the indoor unit, wired-remote controller, and LED s of outdoor unit control board. A two
More informationSystem Administration Guide. Model KS 832. Expandable up to 1664
System Administration Guide Model KS 832 Expandable up to 1664 Introduction 4 Installation Hints 4 System Programming 5 - System Password 5 - Changing Password 5 Exchange Line Set up 6 - Caller Display
More informationSERVICE & SETUP MANUAL WATER HEATER ELECTRONIC CONTROLLER. PVI Industries, LLC 3209 Galvez Dr Fort Worth, Texas 76111 800-784-8326
SERVICE & SETUP MANUAL WATER HEATER ELECTRONIC CONTROLLER PVI Industries, LLC 3209 Galvez Dr Fort Worth, Texas 76111 800-784-8326 Page 1/ 24 PV500-41 10/2013 INDEX 1. TECHNICAL DATA 3 2. WIRING DIAGRAMS
More informationOrdering Part Numbers: Universal Signal Converter: USC-CVB225-01 Universal Signal Converter with a 4-20mA input and +/- 10V output: USC-CVB225-B10V
Description: The universal signal converter offers threeway isolation and translates one input control signal into one to three simultaneous outputs. Switches allow the user to select the desired input
More informationHow to use the OMEGALOG software with the OM-SQ2010/SQ2020/SQ2040 Data Loggers.
How to use the OMEGALOG software with the OM-SQ2010/SQ2020/SQ2040 Data Loggers. OMEGALOG Help Page 2 Connecting Your Data Logger Page 2 Logger Set-up Page 3 Download Data Page 8 Export Data Page 11 Downloading
More informationModel PBX 308 Plus System Administration Guide
Model PBX 308 Plus System Administration Guide Introduction 4 Installation Hints 4 System Programming 5 - System Password 5 - Changing Password 5 Exchange Line Set up 6 - Caller Display 6 - Setting Date
More informationOVERVIEW SALES END OF DAY TIMECLOCK LOGIN PRACTICE. QuickBooks Point Of Sale User Manual
OVERVIEW SALES END OF DAY TIMECLOCK LOGIN PRACTICE QuickBooks Point Of Sale User Manual Overview QuickBooks Point of Sale (POS) is used to ring up sales, manage customers, provide inventory control, and
More informationInternational University of Monaco 11/06/2012 09:27 - Page 1. Monday 30/04 Tuesday 01/05 Wednesday 02/05 Thursday 03/05 Friday 04/05 Saturday 05/05
International University of Monaco 11/06/2012 09:27 - Page 1 Master in Finance - Hedge Funds and Private Equity - from 30 avril to 05 mai 2012 Monday 30/04 Tuesday 01/05 Wednesday 02/05 Thursday 03/05
More informationProcidia Control Solutions Dedicated Backup in a Single Variable Control Loop
APPLICATION DATA AD353-109 Rev 3 April 2012 Procidia Control Solutions Dedicated Backup in a Single Variable Control Loop In critical control applications, a dedicated backup controller can provide increased
More informationDielectric Withstand and Ground Bond Testers For Production Line Safety Agency Compliance Testing
Dielectric Withstand and Ground Bond Testers For Production Line Safety Agency Compliance Testing U.S. patent#: 5,548,501, 6,054,865. Other patents pending. Safety agency listed. ENHANCED GRAPHIC LCD The
More informationMAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss heating
MAKING MORN LIVING POSSIBLE Danfoss heating living connect Installation and User Guide Contents 1.0 System overview... 3 2.0 Overview of display and control buttons... 3 3.0 Installation - step by step...
More informationFire Alarm Control Panel. Family. Operating Manual
Fire Alarm Control Panel Family Operating Manual CONTENTS System Description AH-03312 System Characteristics... Fire Signal Receiving Board Description-4L... Fire Signal Receiving Board Description-8L...
More informationSolar Tracking Controller
Solar Tracking Controller User Guide The solar tracking controller is an autonomous unit which, once configured, requires minimal interaction. The final tracking precision is largely dependent upon the
More informationHEAT SIPHON ANSWERBOOK
ERROR CODES -Displayed on Player Board There are three different types of error codes displayed by the Digital Player Controller" 1 WARNING CODE - The Warning Code is displayed for the duration the error
More informationLS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL
EPSOLAR LS1024B / LS2024B/ LS3024B Solar Charge Controller USER MANUAL Thank you very much for selecting our product! This manual offers important information and suggestions with respect to installation,
More informationAutomation System TROVIS 5100 Ventilation Controller TROVIS 5177
Automation System TROVIS 5100 Ventilation Controller TROVIS 5177 ounting and Operating Instructions EB 5177 EN Electronics from SASON Firmware version 1.05 Edition September 2000 Contents 1 Scope of the
More informationVOLTAGE REGULATOR AND PARALLEL OPERATION
VOLTAGE REGULATOR AND PARALLEL OPERATION Generator sets are operated in parallel to improve fuel economy and reliability of the power supply. Economy is improved with multiple paralleled generators by
More informationFL ballasts Electronic dimming. PCA T5 BASIC lp Y II, 14 80 W BASIC T5
T5 TC-L PCA T5 BASIC lp Y II, 1 80 W BASIC T5 Product description Processor-controlled ballast with y II inside Highest possible energy class CELMA EEI = A1 BAT 1 Noise-free precise control via DSI signal,
More information500r+ Installation and User Guide
500r+ Installation and User Guide Compatible Equipment 502rUK-50 Watch/Pendant PA. 509rUK-50 Smoke Detector 515rUK-00 10 metre passive infra red movement detector. 525rUK-00 Remote Set/Unset (Full and
More informationABB i-bus EIB / KNX Analogue Input AE/S 4.2
Product Manual ABB i-bus EIB / KNX Analogue Input AE/S 4.2 Intelligent Installation Systems This manual describes the functionality of Analogue Input AE/S 4.2. Subject to changes and errors excepted. Exclusion
More informationWA Manager Alarming System Management Software Windows 98, NT, XP, 2000 User Guide
WA Manager Alarming System Management Software Windows 98, NT, XP, 2000 User Guide Version 2.1, 4/2010 Disclaimer While every effort has been made to ensure that the information in this guide is accurate
More informationFlexPak 3000 Digital DC Drive Software Reference Manual Version 4.3
FlexPak 3000 Digital DC Drive Software Reference Manual Version 4.3 Instruction Manual D2-3405-2 The information in this manual is subject to change without notice. Throughout this manual, the following
More informationArc Flash Mitigation. Remote Racking and Switching for Arc Flash danger mitigation in distribution class switchgear.
Arc Flash Mitigation Remote Racking and Switching for Arc Flash danger mitigation in distribution class switchgear. Distance is Safety We will discuss through examples of actual occurrences and possible
More informationSection 6 Fire Detection and Alarm Systems Russell Porteous Chief Executive Officer Firewize Services
Section 6 Fire Detection and Alarm Systems Russell Porteous Chief Executive Officer Firewize Services General Information Section 6 of AS1851-2012 covers: Fire Detection and Alarms Systems Electrical Detection
More informationDigital vs. Analogue Control Systems
Digital vs. Analogue Control Systems Presented at the 2011 Annual Meeting of the American College of Medical Physics, Chattanooga, TN, May 1, 2011 Ivan A. Brezovich, PhD, Dept. of Rad Onc, Univ of Alabama
More information3D SCANNERTM. 3D Scanning Comes Full Circle. s u n. Your Most Valuable QA and Dosimetry Tools A / B / C. The 3D SCANNER Advantage
3D SCANNERTM 3D Scanning Comes Full Circle Relative 3D Dosimetry offering the easiest setup, most objectivity, and best consistency available The 3D SCANNER Advantage Advanced Design Ring and diameter
More informationLLRF. Digital RF Stabilization System
LLRF Digital RF Stabilization System Many instruments. Many people. Working together. Stability means knowing your machine has innovative solutions. For users, stability means a machine achieving its full
More informationHow To Set The Sensor On A Powerpoint 3.5 (Powerpoint) On A Blackberry 2.5A (Powerplant) On An Iphone Or Ipad (Powerplant) On The Blackberry 3.2 (
VMBGPOD Touch panel with Oled display for VELBUS system 1 Binairy format: bits Description
More information3FBD DC Motor Drive User Manual
3FBD DC Motor Drive User Manual Via I. Alpi 6 - zona industriale - Lonato (BS) Tel. +39 30 9913491 r.a. Fax. +39 30 9913504 http://www.re-elettronica.it info@re-elettronica.it Pag. 1 Index Index... pag.1
More informationAPPLICATION FOR EMPLOYMENT
PERSONAL INFORMATION APPLICATION FOR EMPLOYMENT Date Last First Middle Maiden Present address Number Street City State Zip How long Telephone ( ) If under 18, please list age E-mail EMPLOYMENT DESIRED
More informationTwinCAT NC Configuration
TwinCAT NC Configuration NC Tasks The NC-System (Numeric Control) has 2 tasks 1 is the SVB task and the SAF task. The SVB task is the setpoint generator and generates the velocity and position control
More informationDigital Controllers ACTUATOR COMPATABILITY
Product Specification 36502B DESCRIPTION APECS DPG-21XX-00X Digital Controllers The DPG-21XX-00X digital controller is used primarily to govern diesel or gas fueled engines of generator sets. This microprocessor-based,
More informationInwall Room Temperature Unit
Inwall Room Temperature Unit TM11B01KNX TM11B11KNX TM11B21KNX Product Handbook Product: Inwall Room Temperature Unit Order Code: TM11B01KNX TM11B11KNX TM11B21KNX Application Program ETS: TM11B_1KNX Inwall
More informationS I E R R A PRODUCT INFORMATION GUIDE FOR HOME SECURITY. SIERRA Page 1
S I E R R A PRODUCT INFORMATION GUIDE FOR HOME SECURITY SIERRA Page 1 C O N T E N T S USING YOUR SIERRA SYSTEM: Turning On/Off Home Arming Instant Home Arming Quick Exit Mode Chime Mode SPECIAL FUNCTIONS:
More informationSi10-417_C. Pocket Manual. Service Diagnosis SPLIT & MULTI
Pocket Manual Service Diagnosis SPLIT & MULTI Service Diagnosis SPLIT & MULTI 1. Troubleshooting with LED...5 1.1 Indoor Unit... 5 1.2 Outdoor Unit... 10 2. Troubleshooting by Symptoms...11 2.1 Air conditioner
More informationSupply Module for AC Drives. Indramat. mannesmann Rexroth. Error Messages, Diagnostics and Fault Clearance DOK-POWER*-GENEREL****-WAR1-EN-P
engineering mannesmann Rexroth Supply Module for C Drives Error Messages, Diagnostics and Fault Clearance DOK-POWER*-GENEREL****-WR1-EN-P 271430 Indramat bout this documentation Title Type of documentation
More informationAnalog Electronics I. Laboratory
Analog Electronics I Laboratory Exercise 1 DC Power Supply Circuits Aim of the exercise The aim of this laboratory exercise is to become familiar with rectifying circuits and voltage stabilization techniques
More informationUnified requirements for systems with voltages above 1 kv up to 15 kv
(1991) (Rev.1 May 2001) (Rev.2 July 2003) (Rev.3 Feb 2015) Unified requirements for systems with voltages above 1 kv up to 15 kv 1. General 1.1 Field of application The following requirements apply to
More informationFossil fuel heating equipment
Fossil fuel heating equipment principles and troubleshooting techniques Application Note This application note was written to provide you with an understanding of the basic principles of fossil fuel heating
More informationAutoflame PC Software Guide
Autoflame PC Software Guide Autoflame PC Software Guide Issued by: AUTOFLAME ENGINEERING LTD Unit 1-2, Concorde Business Centre Airport Industrial Estate, Wireless Road Biggin Hill, Kent TN16 3YN Tel:
More informationCharacterised control valve (CCV) with adjustable flow rate and sensoroperated flow control, and power and energy-monitoring function
Belimo Energy Valve TM web server manual P6..W..EV-BAC Characterised control valve (CCV) with adjustable flow rate and sensoroperated flow control, and power and energy-monitoring function Contents General
More informationInstaller guide. Release 2.2
Installer guide Release 2.2 Important safety notice h r j n l s The following safety regulations must be observed at all times. Failure to observe precautions could result in severe injury or death. jj
More informationBy Authority Of THE UNITED STATES OF AMERICA Legally Binding Document
By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document By the Authority Vested By Part 5 of the United States Code 552(a) and Part 1 of the Code of Regulations 51 the attached document has
More informationGTEC transfer switch open transition
GTEC transfer switch open transition 40-1250 Amp Description The GTEC automatic transfer switch combines reliability and flexibility in a small, economical package for transferring loads between a utility
More informationHow To Install Galaxy Desktop On A 64 Bit Computer (For A 64Bit) On A 32 Bit Computer Or Ipad Or Ipa (For An Ipa) On An Ipad (For Pc) Or Ipac (For Mac) On
Galileo Desktop 2.5.0.3T Automated Installer Use the Galileo Desktop 2.5 Installer to automate the Galileo Desktop 2.5 installation, please take note that some of the images found here may reflect differently
More informationConventional Fire Detection and Extinguishant Control System Specification
Conventional Fire Detection and Extinguishant Control System Specification Page 1 of 9 Scope Furnish a complete 24VDC Conventional, electrically supervised, combined fire detection and extinguishant release
More information7 Using the Alarm Ready Schedule
7 Using the Alarm Ready Schedule Feature 7.1 Definition An Alarm Ready Schedule is defined as an interval of time during which the Verbatim autodialer is ARMED and Ready to respond to alarm conditions.
More informationTHERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES
TSI and TSI logo are registered trademarks of TSI Incorporated. SmartTune is a trademark of TSI Incorporated. THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES IFA 300 Constant Temperature Anemometry
More informationTS590. Intruder Alarm Control Panel. SYSTEM OPEN 17:30 01 Jan ENT 0 ESC
TS590 Intruder Alarm Control Panel 7:0 0 Jan _ ~ A B 5 6 C 7 8 9 D 0 ESC Setting the System Enter your passcode XXXX then leave the protected area. Unsetting the System Go directly to the keypad and en
More informationInternational University of Monaco 27/04/2012 14:55 - Page 1. Monday 30/04 Tuesday 01/05 Wednesday 02/05 Thursday 03/05 Friday 04/05 Saturday 05/05
International University of Monaco 27/04/12 14:55 - Page 1 Master in International Business and Global Affairs - from 30 avril to 05 mai 12 Monday 30/04 Tuesday 01/05 Wednesday 02/05 Thursday 03/05 Friday
More informationSMART SENSOR COLLECTION
TEMPERATURE SENSOR This sensor measures temperature in degrees Celsius or Fahrenheit. It works with all SensorHawk base units (SensorHawk-2, SensorHawk-8 and SensorHawk8/20) as well as the SecurityHawk-8
More informationInternational University of Monaco 21/05/2012 16:01 - Page 1. Monday 30/04 Tuesday 01/05 Wednesday 02/05 Thursday 03/05 Friday 04/05 Saturday 05/05
International University of Monaco 21/05/12 16:01 - Page 1 Master in International Sport Business and Management - from 30 avril to 05 mai 12 Monday 30/04 Tuesday 01/05 Wednesday 02/05 Thursday 03/05 Friday
More informationNX Series Inverters. HVAC Pocket Programming Guide
NX Series Inverters HVAC Pocket Programming Guide HVAC Pocket Programming Guide HVAC Pocket Programming Guide / Contents This guide provides a single reference document for the user of NXL HVAC (product
More informationB/S/H/ Error codes and service programmes PH
1 ERROR CODES AND APPLIANCE MESSAGES... 3 1.1 Complete overview of all error codes (in order)... 3 Automatic switch-off... 3 Display is dark and any individual LEDs are lit... 3 E 005... 3 E 011... 3 E
More informationManagement Systems 10 Electrical Safety Audit 14 PPE 20 Arc Mitigation 22 Hazard Assessment 26
Management Systems 10 Electrical Safety Audit 14 PPE 20 Arc Mitigation 22 Hazard Assessment 26 Assessing The Hazards Of High and Low Voltage Single-Phase Arc-Flash By Albert Marroquin One common question
More informationFTDI VCP DRIVER (free) (WIN/MAC/LINUX) http://www.ftdichip.com/drivers/vcp.htm
002 - CONNECTING THE PRINTER Now that you have an idea what 3D printing entails, we can continue and connect the printer to your computer. First make sure you have a computer with a decent amount of RAM
More informationAlpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions
Alpha Climatic Programmable Modulating Boiler Energy Manager Part No 3.022144 (Hard Wired) Part No 3.022143 (Radio Frequency) Installation and User Instructions 1. Description The Alpha Climatic energy
More informationFlexible Counter Series in DIN size 24 x 48 mm
Flexible Counter Series in DIN size 24 x 48 mm high contrast 8-digit LCD display or brilliant 6-digit LED display 2 different supply voltages available: independent of mains supply with lithium battery
More informationMulti-Range Programmable DC Power Supplies 9115 Series
Data Sheet 1200 W Multi-Range DC Power Supplies Features & Benefits Any 9115 series model can replace several supplies on your bench or in your rack. Unlike conventional supplies with fixed output ratings,
More informationCoupling- / Decoupling Network. 150 khz 300 MHz. 150 khz 230 MHz. 10 khz 230 MHz. IEC 61000-4 - 6 and CISPR 15 / CISPR 22 IEC 61000-4 - 6
Coupling- / Decoupling Network 150 khz 300 MHz IEC 61000-4 - 6 and CISPR 15 / CISPR 22 150 khz 230 MHz IEC 61000-4 - 6 10 khz 230 MHz IEC 61000-4 - 6 and IEC 61326-3 - 2 and NAMUR Coupling and decoupling
More informationThe APS Machine Protection System (MPS) *
The submitted manuscript has been authored by a contractor of the U. S. Government under contract No. W-31-109-ENG-38 Accordingly, the U. S. Government retains a nonexclusive, royalty-free license to publish
More informationBrake module AX5021. Documentation. Please read this document carefully before installing and commissioning the brake module!
Documentation Brake module AX5021 Please read this document carefully before installing and commissioning the brake module! Version : 1.2 : 2012.03.05 Date Article-no. : TDmlAX-5021-0000-0200 Page 2/8
More informationMV, HV AND EHV SWITCHGEAR TESTING & COMMISSIONING
Training Title MV, HV AND EHV SWITCHGEAR TESTING & COMMISSIONING Training Duration 5 days Training Date MV, HV and EHV Switchgear Testing & Commissioning 5 20 24 Apr $3,750 Dubai, UAE In any of the 5 star
More information