Variable Preset Counter signo 723.1
|
|
|
- Toby Kelley
- 9 years ago
- Views:
Transcription
1 Variable Preset Counter signo Large, 6-digit, 14 mm high LED display Up/down counter with prescaler 2 presets, one programmable as trailing preset Easy direct selection by 2 function keys 2 relay outputs with change-over contacts Keypad can be secured against unauthorized access npn/pnp-programming of inputs RS 232 / RS 485 interface optional DISPLAY 6-digit LED display with 14 mm high figures, easy to read, decimal point can be programmed. B P1 P2 Set PSC signo 723 A PROGRAMMING Section A Section B: Shows the actual counting position when in counting mode, and the changeable parameters when in programming mode. LED indicators showing the active output signal, and in programming mode indicating the changeable parameter. Direct access with functionkeys F1 and F2 Operation level 1 Operation level 2 Operation level 3 P 1: Preselection 1 P 2: Preselection 2 SET: setvalue PSC: Prescaler system parameters -,-,-,- Decimalpoint Programming of signo is divided into 3 operation levels and direct access. Direct access: Preselection 1 and 2 can be directly selected by the function keys F1 and F2 Operation level 1: Includes the set value Operation level 2: Includes machine parameters and application specific parameters. Operation level 3: Includes system parameters like operation modes and count modes, which mormally are programmed during start-up procedure. Unauthorized programming of the signo is prevented by a control input, which can lock the operation levels as well as the operation keys. 143
2 signo Technical data TECHNICAL DATA Display LED, 6 digits, suppression of leading zeros, programmable decimal point, minus sign Digit Height 14 mm Power Supply Voltage V op VDC or 115/230 VAC depending on version Current Consumption VDC < 250 ma, 115/230 VAC < 60 ma Sensor Supply AC-operation: VDC, DC-operation: V op - 2 V, Imax. = 60 ma Data Retention non-volatile memory > 10 years Operating Temperature 0 50 C Storage Temperature C Electrical Connection plug-in terminals Mounting with clamping frame Protection Class (IEC 144) front side IP 54, terminals IP 20 Noise Immunity EMC severity 3 according to IEC 801, part 2 + part 4 Vibrostability 10 m/s 2 ( Hz) according to IEC 68-part 2-6 Shock Stability 100 m/s 2 (18 ms) according to IEC 68-part 2-27 General Rating according to VDE 0411, DIN 57411, protection class II Inputs: Switching Level Active Edge Pulse Shape Input Resistance <2 V and >8 V, max. 40 VDC positive when pnp or negative when npn, can be switched over any (square 1:1 at max. frequency) approx. 5 kω (static) Count Input with prescaler programmable as phase discriminator input with single, double or quadruple evaluation as differential input as up/down input Pulse Duration 12.5 µs (40 khz), 17 ms (30 Hz) Count Frequency max. 40 khz or 30 Hz Control Input: Reset Gate Hold Keylock manual by reset key external by reset input, static or dynamic, programmable pulse duration min. 3 ms (attenuated min. 17 ms) automatic when reaching preset 2 static, pulse duration > 12 µs / >17 ms static, pulse duration > 3 ms static, pulse duration >3 ms Outputs: Relay Out 1 and 0ut 2 Contact Type changeover relay Switching Voltage max. 250 VAC / 30 VDC, min. 5 VAC/DC Switching Current max. 1A, min. 10 ma Transistor Out 1 and Out 2, PNP, 10 ma 144
3 Technical data signo DIMENSIONS 723 plug-in terminals clamping frame dimensions in mm CONNECTION DIAGRAM ORDER INFORMATION Version Supply Voltage Ordering code without interface VDC /230 VAC This counter is available with several interfaces. See next pages. 145
4 signo 723 signo 727 Variable Preset Counter and Position indicator with Interface RS 485 / RS 232 Large 6 digit LED display, 14 mm Up-/down counter, 6 digits, with different count modes and prescaler 2 preset values or 2 limit values Transistor outputs (PNP) and relay outputs (changeover contacts) Compact DIN 48 x 96 mm Easy manual operation with function keys Interface: RS 485 or RS 232 TECHNICAL DATA Power Supply Voltage Sensor Supply VDC or 115/230 VAC AC-operation: VDC, DC-operation: Vop-2V, Imax. = 60 ma Inputs: Switching Level < 2 V and > 8 V, max. 40 VDC Active Edge positive PNP or negative NPN programmable Count Input with prescaler programmable 0, , as phase discriminator input with single, double or quadruple evaluation - as differential input - as up/down input Count Frequency max. 40 khz or 30 Hz Control Inputs Reset, Gate, Hold and Keylock RS 232 Outputs: Relay Transistor maximum length Input R x D typical input resistance max input voltage Input T x D output voltage output current max. Out 1 and Out 2 with changeover contact, 1 A, 250 VAC/30 VDC Out 1 and Out 2 with PNP-Output, 10 ma 15 m 5 kohm 30 V 8 V 20 ma RS 485 Protocol Terminals A and B typical input resistance max input voltage output level output current max. maximum bus length data transfer rate data format 12 kohm V High: 3.5 V, Low: 1.3 V 60 ma 2000 m 1200, 2400, 4800 Baud 7 bits, even parity 8 bits, no parity stop bits 1 protocol Hengstler TP3 or ASCII (depending on version) For further technical information please refer to the pages describing signo and signo
5 Technical data signo 723 signo 727 DIMENSIONS socket connectors Clamping frame panel cutout: 45 x 92 dimensions in mm 108 CONNECTION DIAGRAM PRINTER PROTOCOL FOR Protocol Baudrate Data format Standard ASCII 1200, 2400, 4800 Baud 7 Bits, even Parity, 1 Stop bit 8 Bits, no Parity, 1 Stop bit Line and Form Feeds programmable before and after printout Cutter Control programmable PRINT MASKS The counter allows for the programming of 5 different print masks Mask 0 only Count Value Mask 1 Counters: <value> Mask 2 Counter: <value> Mask 3 Counter: <value> Preset1: <value> Preset2: <value> Set: <value> Prescaler: <value> Mask 5 Length: <value> m 147
6 signo 723 signo 727 Technical data ORDER INFORMATION Counter Counter with time counter PC-driversoftware for TP3 Protocol RTC Converter RS 485 / RS 232 Version with interface VDC 115/230 VAC signo 723 Printersoftware RS M M1 signo 723 TP3 Protocol RS M M3 RS M M3 signo 727 TP3 Protocol RS M M3 RS M M3 signo 723 TP3 Protocol RS Windows 3.X Windows 95 / NT DOS (ab 3.2) vt3com.exe TP3.com RTC Plug-in power supply for RTC Connection cable RTC-PC (RS 232), 5 m RTC Remote Terminal Converter The RTC is needed if more than one counter is to be connected to the PC or if the distance between the machine and the PC is longer than 15 m. up to 31 counters can be connected to the RTC via RS 485 bus Connection RTC - PC is a standard RS 232 optimally tuned for operation with the Hengstler Software HTS (Hengstler Terminal Server) Power supply VDC or VAC, max. 2 VA (plug-in power supply available as accessory) DIMENSIONS width 115 mm / height 38 mm / depth 165 mm CONNECTION DIAGRAMS Connector ST 1 pin signal 1 AC/DC 2 Earth 3 AC/DC Connector ST 3 pin signal 1.3 RS 485 A RS 485 B - 5 Earth Connector ST 2 pin signal description 1 DCD Carrier Detect 2 RXD Receive Data 3 TXD Transmit Data 4 DTR Data Terminal Ready 5 GND Signal Ground 6 DSR Data Set Ready 7 RTS Request To Send 8 CTS Clear To Send 9 RI Ring Indicator 148
7 Windows Software HTS for Counters signo 723 signo 727 Guided Setup A program group and start icon are created automatically Setup registers the OLE attributes of HTS in the Windows registry DDE- and OLE Server EXAMPLE Logical counter adress Const CounterAddress = 25 registers of a counter Const CounterValue = 0 Const Preset1 = 1 Const Preset2 = 2 Const Chain = 3 Reading and writing a counter from within MS Excel: read counter and insert result in table 1 Sub Read_Counter() Set Hts = GetObject(Class:= Hengstler.TerminalServer.10 ) Result = Hts.ReadRegister(CounterAddress; CounterValue) Sheets( Table1 ).Cells(6; 2).Value= Result Ende Sub Sub Write_Counter() Data = Sheets( Table1 ).Cells(2; 2).Value Set Hts = HoleObject(Class:= Hengstler.TerminalServer.10 ) Result = Hts.WriteRegister(CounterAddress; CounterValue; Data) Ende Sub Connection to DOS Hengstler Terminal Driver vt3com.exe The driver can be called in several ways: Command line (DOS prompt) within a batch file from within an application, e.g. via system() function call Automatic handling of several counter registers by means of a job file. EXAMPLE Example of a driver call (uploading preset value 2): literal value: vt3com.exe 25 dw I002 #89462 value out of a file:vt3com.exe 25 dw I002 value.dat 149
8 signo GLZ Variable Preset Counter with PTB-Approval Versions with Programmable Prescaler large, 6-digit, 14mm high LED display up/down counter with programmable resolution (dm, cm or mm) 2 preselections of which one is programmable as trailing signal easy direct selection by 2 lockable function keys two relay outputs with change-over contacts keypad can be secured against unauthorized access also available with printer interface For measuring belt systems versions with programmable prescaler COMPONENTS FOR THIS LENGTH MEASURING SYSTEM see also under PTB approved measuring systems Measuring wheel Circumference 20 cm Counter Type signo GLZ Ordering code with printer interface Printer Type Primo Measuring wheel Circumference 50 cm Shaft encoder Type RI 58-O Counter signo GLZ Ordering code without printer interface Type signo Ordering code TECHNICAL DATA Count input Phase discriminator with single evaluation, impulse resolution in mm, cm, dm (Standard) Prescaler (only-p version) Length Resolution Pulse Duration min µs Count Frequency max. 40 khz programmable in dm, cm or mm by adjusting the decimal point (Standard version) or programmable with prescaler Control Inputs: Reset Gate Display Hold Keylock manual by reset key external, static or dynamic, programmable pulse duration: >3 ms or >17 ms static, pulse duration >12 µs >17 ms static, pulse duration >3 ms static, pulse duration >3 ms All other data are according to signo ORDER INFORMATION Type Standard Supply Voltage Ordering Code signo GLZ 115/230 V AC signo GLZ with RS 232 interface V AC Type with Prescaler Supply Voltage Ordering Code signo GLZ-P 115/230 V AC signo GLZ-P with RS /230 V AC
9 Flexible Counter Series, Dual tico 735 Colour Display in DIN size 48 x 96 mm COUNTING - MEASURING - INDICATING - MONITORING - TRANSMITTING Because of the unlimited number of measurements it can handle, the tico 735 device family is equally well suited to applications in the world of impulse and time counting as to those in the processing area. If you are looking for display clarity and high levels of accuracy, then the tico 735 is the right choice for you. The dual-colour display is unique, highlighting an alarm situation or an excess value at a single glance. You can programs your own choice of display colour to indicate normal or alarm conditions. FEATURES Brilliant 18.5 mm high dual-colour red/green LED display with programmable colour settings As standard, all models have limit or preset values Scaling available as standard Universal Power Supply V AC or V AC/DC Simple structured operation with switchable help function External Program Lockout DIN housing 48 x 96 mm, mounting depth < 100 mm Conveniently sized Screw Terminals Large keys offer safety and ease of operation NPN and Relay Outputs Option: RS 485 ASCII protocol serial interface for all versions. Remote Display version receives process values over RS 485 PRESET COUNTER (1 Preset, 2 Presets) BATCH COUNTER Input Modes, Features Value Range A+B, A-B, Direction, Quad or 2 Presets (P 1 as absolute Preset or Prewarn) Up/down with or without auto reset mode 0 -> P 2, P 2 -> 0 Out 1 and Out 2 separetely programmable latch or Sec A+B, A-B, Direction, Quad Up/down with or without auto reset mode 0 -> P 1, P 1 -> 0 Preset, Batch Preset, Totalizer Out 1 and Out 2 separately programmable latch or Sec 137
10 tico 735 Technical data DIMENSIONS tico PGM RST Dimensions in mm DISPLAY AND KEYBOARD PHYSICAL Primary Display Secondary Display Output Indicators Keyboard Front Dimensions Mounting Panel Cutout Construction Terminals Red/Green, 7 segment LED, 5 digits, height 18.5 mm single digit 7 segment LED, height 7 mm, red/green 2 red LEDs for OUT 1 and OUT 2 status 4 rubber keys for programming and manual reset DIN 48 mm x 96 mm, 110 mm total depth Front panel mounting (mounting bracket supplied) 45 mm x 92 mm, panel thickness max 12 mm Front carrier with PCBs can be pulled out Screw Type (combination head) OPERATING CONDITIONS APPROVALS Power Supply V AC 50/60 Hz (electrically separated from all inputs and outputs) or V AC / V DC Temperature Operation: 0 C to +55 C (32 F to 131 F) Storage: -20 C to +60 C (-4 F to 176 F) Relative Humidity 0 to 90 %, non-condensing Protection Frontpanel IP 66 CE EN /92-95; EN /92, -2/94 Safety DIN EN part 1; protection according to class II General UL, CUL, Overvoltage cat. II, Contamination level 2 OPTION: RS 485 Type Parameters RS 485, serial asynchronous, Open ASCII, Master-Slave, up to 99 zones Bd, 1 start, 7 data, 1 stop, even parity 138
11 Technical data tico 735 TERMINALS VDC/AC or VAC ~ ~ NC RS 485 B A + 0V Relay OUT Linear NC Output Relay OUT OUT2 NPN 0V OUT1 NPN CTRL 2 CTRL 1 Aux. Power 0V Input A Input B COUNT INPUTS Active Edge NPN or PNP programmable; capable of TTL; 30 V DC max with PNP High 3.0 V, Low < 2.0 V or open; 10 kohm to 0 V with NPN High 3.0 V or open, Low < 2.0 V; 4.7 kohm to V+ Frequency 20 Hz, 200 Hz or 10 khz programmable CONTROL INPUTS OUTPUTS SPECIAL FEATURES CTRL1 NPN; High 3.0 V or open, Low < 2.0 V; 4,7 kohm to V+ (Reset or hold) edge sensitive; 25 ms min., max 30 V DC CTRL 2 NPN; High 3.0 V or open, Low < 2.0 V; 4,7 kohm to V+ (Progr. security)) level sensitive; 25 ms min.; max 30 V DC OUT 1 NPN NPN, open collector; 30 V DC max; 100 ma max OUT 2 NPN response time < 75 µs Relay 1, Changeover (Form C); 240 V AC / 3A or 110 V AC / 5 A; pull-in Relays 2 (opt.) time 8 ms Auxiliary (unregulated V DC), 125 ma max; residual ripple < 0.5 V Power Supply Display colour programmable Count Calibrator to as standard Preset Lockout and Reset Disable programmable Program Security via CTRL 2 ORDERING DATA Type 0735 P Output Relay 2 0 none 1 with Relay 2 not for function 1, 6, 7 Interfaces 0 none 5 with RS P Function 1 Totalizer 2 Position Indicator 4 Tacho/Rate Meter 5 Rate + Totalizer 6 Time Counter 7 1 Preset Counter 8 2 Preset Counter 9 Batch Counter Linear Output 0 none 3 with 4-20 ma (only with function 2, 4, 5) Option module Ordering code Relay RS 485 interface Power Supply V AC V AC or V DC 139
Preset Counter signo 721
Most simple handling Impressive, clearly readable display in 48x48 mm Input frequency up to 60 khz Easy installation due to pluggable terminals TECHNICAL DATA GENERAL Display Height of digits Supply voltage
Flexible Counter Series in DIN size 24 x 48 mm
Flexible Counter Series in DIN size 24 x 48 mm high contrast 8-digit LCD display or brilliant 6-digit LED display 2 different supply voltages available: independent of mains supply with lithium battery
Multifunction devices
devices devices devices, electronic Type Page LED multifunction displays pulse, frequency, time (DC) Codix 524 240 pulse, frequency, time (AC+DC) Codix 544 243 LCD multifunction preset counters 1 or 2
Quick Connect. quick - simple - efficient. www.g-mw.de
Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power
RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:
Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog
Industrial Counting and Control Components
Industrial Counting and Control Hengstler Products Encoders Absolute Encoders ACURO drive and ACURO industry, Incremental Encoders, Ex-proof and stainless steel versions, Bus Encoders Industrial Counting
Automation System TROVIS 6400 TROVIS 6493 Compact Controller
Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general
Short information Parameters are programmed via front-side membrane keypad
Digital remote display for Flow Meter DM /DE Universal meter UZ Indication of the quantity consumed in m³ Features LED-Display 14.2mm red Indicating range -99999... 999999 0... 3 Decimal points programmable
Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5
Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service program ULTRA 000 programmable switch outputs Hysteresis
RS - SPM. Serial parallel translator module
ReSatron GmbH Boisheimer Str. 162 D-41751 Viersen Telefon (+49) 02162-45 06 80 Telefax (+49) 02162-45 03 04 email: [email protected] RS - SPM Serial parallel translator module RSSPM000215SPM-021 - Subject
Panel Meters and Controllers Modular Panel Meter Type EDM 35
Panel Meters and Controllers Modular Panel Meter Type EDM 35 Modular digital panel meter, 3 1/2-digit Indicating or controlling current, voltage, resistance, temperature, tacho or frequency. Easy programming
ERMA-Electronic GmbH - Max-Eyth-Str.8-78194 Immendingen - Tel: +49(0)7462/2000-0 - Fax: +49(0)7462/2000-29. Technische Änderungen vorbehalten
Panel mounting instruments / DIN cabinets mounting different standard housing sizes different supply voltages all usual measured variables Measuring instruments programmable industrialfair execution customized
Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in
Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in Single or Dual loop detector Automatically adjustment of detection level Manual sensitivity for compensations of variations Easy installation
JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
HERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
HSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: [email protected] NTG-3000.
NTG-3000 Transducer Data Sheet Document Version 2.8 Page 1 of 10 Versions / Revisions: Document Creation Author Description version date 2.0 2012-07-25 P. Compensis First official version 2.1 2012-08-24
How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)
transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control
Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D
7000/7000C/7020 Multi-instrument 4921210109D Features Measurements All 3-phase AC measurements True RMS Replaces analogue meters Demand on each phase current Accuracy U, I and F class 0.5 Other values
Housing diameter Shaft diameter 1. Flange (Mounting of housing) Protection class shaft input (EN 60529) Protection class housing (EN 60529)
Direct mounting without coupling Flexible hollow shaft design up to diameter 4 mm Through hollow shaft or as end shaft (blind shaft) Easy installation by means of clamping shaft or blind shaft Short overall
SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications
Fiber Optic Sensors - S7 Advanced fiber optic amplifiers for high speed and low contrast applications DIN rail mountable models with dual digital displays speed models: 2 μs...5 ms Super high speed models:
Digital input modules
8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a
RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER
Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.
Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc
Ultrasonic sensors for high precision detection of clear and transparent objects Clear object detection, inspection on transparent or highly reflective film and liquid level measurement Standard M18 tubular
Temp-485-Pt100. A temperature sensor (Pt100 or Pt1000) communicating over the RS-485 bus with a simple communication protocol
Temp-485-Pt100 A temperature sensor (Pt100 or Pt1000) communicating over the RS-485 bus with a simple communication protocol Temp-485-Pt100 Box version [600 113] Temp-485-Pt100 Cable version [600 114]
16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide
16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide 1. Introduction Thank you for purchasing this 16-Port RS232 to USB2.0 High Speed Multi Serial Adapter. It is an
HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply
1. INTRODUCTION HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply User Manual This family of efficient, upgraded SMPS with small form factor, auto cross over CV CC,
PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description
Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.
E-STOP relays, safety gate monitors
Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided
INSTALLATION/PROGRAMMING INSTRUCTIONS E4KP ENTRYCHECK
Security Door Controls 3580 Willow Lane, Westlake Village, CA 91361-4921 (805) 494-0622 Fax: (805) 494-8861 www.sdcsecurity.com E-mail: [email protected] INSTALLATION/PROGRAMMING INSTRUCTIONS E4KP
Application/Connection Examples
This Quick Start Guide is designed to familiarize the user with the connection and configuration of the DTS-305 DIN rail mounted single / 3 phase power & energy meter with RS-485 or TCP communications.
RY2 miniature industrial relays
6 RY2 Relays of general application For plug-in sockets, 35 mm rail mount acc. to PN-EN 60715 or on panel mounting Flat insert connectors - faston x 0,5 mm Recognitions, certifications, directives: RoHS,
Duct Humidity Transmitter
SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers
How To Use An Od Max Sensor System For Distance Measurement
OD Max: Highly precise distance measurement thickness or the evenness can be achieved. This is due to the in the system integrated arithmetical functions. D T SHEET Displacement TThe OD Max is an highly
Option field bus: without bus with profibus DP. Design-Index (Subject to change)
Amplifier / controller cards ED1 Digital amplifier / controller card ED1 for 1 or 2 proportional solenoids 4 analogue inputs, of which 2 for differential inputs 8 digital inputs Card setting via PC, multi-function
Input signal Maximum Range Accuracy. Thermocouple E -50 to 700 C (-58 to 1832 F) ±1 C
F4 Process Controller Installation and Operation Guide SAFETY ALERTS The symbols below are used on the equipment and throughout this document to draw the user s attention to important operational and safety
DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters
The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual
Absolute Rotary Encoder E6CP
Absolute Rotary Encoder Absolute Rotary Encoders with Gray Code Output Gray code output decreases output errors Lightweight plastic housing Used with Omron s H8PS Cam Positioner, this encoder detects the
User Manual V1.0 2014 SDM220MODBUS. Single-Phase Two Module DIN rail Meters
SDM220MODBUS Single-Phase Two Module DIN rail Meters Measures kwh, Kvarh, KW, Kvar, KVA, PF, Hz, dmd, V, A, etc. Di-directional measurement IMP & EXP Two pulse outputs RS485 Modbus Din rail mounting 36mm
TECHNICAL DATASHEET Incremental Encoder RI 58-H
Through hollow shaft High accuracy by means of integrated flexible coupling Safe shaft mounting Applications: textile machines, motors, drives, copiers NUMBER OF PULSES 1 / 2 / 3 / 4 / 5 / 10 / 15 / 20
is then retained absolutely without interruption.
Page 1 of 11 DC UPS uninterruptible power supplies - DC UPS module 15 A Compact design, only 50 mm wide Absolutely interruption-free buffering of power failures through immediate electronic connection
MPC 4. Machinery Protection Card Type MPC 4 FEATURES. Continuous on-line Machinery Protection Card
Machinery Protection Card Type FEATURES Continuous on-line Machinery Protection Card Real-time measurement and monitoring using state-of-the-art DSP techniques Fully VME-compatible slave interface Fully
I STAR COMPUTER CO., LTD
I STAR COMPUTER CO., LTD Mini Redundant Power Supply 300W+300W for IPC-Computer Model No. TC-300R8 Table of content 1. Introduction...1 2. Specification 2.1 Input Voltage...1 2.2 DC Output...1 2.3 PS-ON
CPU systron S 200 - S 250 - S 250c. systron S 200 - S 250 - S 250c. CPUs to the process modules. Stand-alone PLC
E031019 000823 systron S 200 - S 250 - S 250c CPU systron S 200 - S 250 - S 250c 45 mm width Flexible and expandable Easy to use software for bus connection (S 250/ S 250c) CPUs to the process modules
Auto-tune PID. Temperature Controller BRAINCHILD FEATURES
Auto-tune PID Temperature Controller FEATURES Easy-to-use Fuzzy modified PID heat & cool control Fast A-D sampling rate (5 times/s) Universal input (PT100, thermocouple) with high accuracy 18-bit A-D Analog
NC-12 Modbus Application
NC-12 Modbus Application NC-12 1 Table of Contents 1 Table of Contents... 2 2 Glossary... 3 SCADA...3 3 NC-12 Modbus in general... 3 4 Entire system... 4 4.1 PFC to PC connection alternatives...4 4.1.1
WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK
WEA-Base User manual for load cell transmitters 1 Contents 1. Technical data... 3 2. Assembly... 4 2.1 Power supply... 4 2.2 Load cells... 4 2.3 RS-485... 4 2.4 Relays... 5 2.5 Digital input... 5 2.6 Analogue
Electronic Control Devices The European Product Catalogue 2007
FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,
A project to optimise quality and energy efficiency must include metering
EMDX 3 : Energy Metering A project to optimise quality and energy efficiency must include metering Metering upstream identifies the critical points and ensures optimum targeting of the actions to be taken,
Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001
Analogue Input, -fold, MDRC, GH Q605 005 R0001 The analogue input is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via the bus connecting terminal supplied.
2-Port RS232/422/485 Combo Serial to USB2.0 Adapter (w/ Metal Case and Screw Lock Mechanism) Installation Guide
2-Port RS232/422/485 Combo Serial to USB2.0 Adapter (w/ Metal Case and Screw Lock Mechanism) Installation Guide 1. Introduction Thank you for purchasing this 2-Port RS232/422/485 Combo Serial to USB Adapter.
Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs
E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation
AC-115 Compact Networked Single Door Controller. Installation and User Manual
AC-115 Compact Networked Single Controller Installation and User Manual December 2007 Table of Contents Table of Contents 1. Introduction...5 1.1 Key Features... 6 1.2 Technical Specifications... 7 2.
Digital Pressure Measuring Instrument MDR480
Description The digital panel instrument MDR480 is designed to measure, display, and monitor pressures in industrial applications. The instrument is panel mounted with a front frame dimension of 96 mm
TECHNICAL DATASHEET Incremental Encoder RI 58-D / RI 58TD
Direct mounting without coupling Flexible hollow shaft design up to diameter 4 mm Through hollow shaft or as end shaft (blind shaft) Easy installation by means of clamping shaft or blind shaft Short overall
Voltage Regulator SPAU 341 C. Product Guide
Issued: July 1998 Status: Updated Version: D/25.04.2006 Data subject to change without notice Features Comprehensive voltage regulation for power transformers with on-load tapchangers in distribution substations
Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface
Release date: 06-0- 09: Date of issue: 06-0- 009_eng.xml Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service
Energy Management Energy Meter Type EM23 DIN
Energy Management Energy Meter Type EM23 DIN Class 1 (kwh) according to EN62053-21 Class B (kwh) according to EN50470-3 Class 2 (kvarh) according to EN62053-23 Accuracy ±0.5 RDG (current/voltage) Energy
Safety technique. Emergency stop module BO 5988 safemaster
Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1
Throughbeam photoelectric sensors. Dimensioned drawing. Electrical connection
Specifications and description Leuze electronic LS 78 Throughbeam photoelectric sensors Dimensioned drawing 180m 10-30 V DC! Voltage range from 12 30VDC with NPN, PNP and/or relay outputs! Light/dark switching!
CONFIGURABLE SAFETY RELAYS
MSI-s/R, MSI-sx/Rx Configurable MSI provide important functions for the efficient flow of automated production processes Special features Combined guarding types by connecting up to 4 AOPDs Additional
ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.
IntesisBox ModBus Server - KNX Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems. Integrate KNX based lighting control into your SCADA, BMS, PLC "talking" Modbus. Master
Smart DeviceNet Remote I/O Terminals
Smart DeviceNet Remote I/O Terminals ather and Use Information for Effective Preventive Maintenance et more useful data for preventive maintenance when you build cost-effective parallel information systems
SKR - industry relay
SKR - industry relay the universal relay SKR the time module STM the socket The strengths of the SKR industry relay lie in the mature and thoughtout construction. Over-average contact safety and life time,
Electrical connection
(I)GSU 14B Ultrasonic Label Fork Dimensioned drawing Part No. 501 09234 4mm 12-30 V DC 4 m/s Ultrasonic forked sensor for universal application Large mouth width, hence also suitable for booklets or fan-fold
Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.
Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description
0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N
55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils
Energy Management Power Analyzer Type WM14-96 Basic Version
Energy Management Power Analyzer Type WM-96 Basic Version Optional dual pulse output Alarms (visual only) V, An Optional galvanically insulated measuring inputs Product Description 3-phase power analyzer
Applications. diris_826_a_1_gb_cat
Measurement units NEW diris_824_a_1_cat Energy monitoring and management of low voltage/ high voltage electrical installations Function are measurement units which can provide all the functions offered
DC Electronic Loads 8500 series
Data Sheet DC Electronic Loads 8500 series 2400W 600 W - 1200 W 300 W Versatile & Economical DC Electronic Loads The 8500 series Programmable DC Electronic Loads can be used for testing and evaluating
PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS
PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS FRANCE Head office USA 4 Rue du Bois Chêne le loup Parc d Activité de Brabois 54 500 VANDOEUVRE LES NANCY (33) 0383442413, Fax (33) 0383443797
Fiessler Programmable Safety Center. Flexible Hard- and Software concept. Available with a safe bus system or/and two counter inputs
E L E K T R O N I K Appliance Description Programmable safety center FPSC Fiessler Programmable Safety Center Flexible Hard- and Software concept Available with a safe bus system or/and two counter inputs
Vibration Monitoring System Adash 3600
" User's guide Application: Vibration Monitoring System Adash 3600! Vibration diagnostics, monitoring and protective on-line system! On-line vibration monitoring system of engines, fans, pumps, gearboxes,
g9sp Programmable Safety controllers compact Stand-Alone Programmable controller NEW! example of System configuration G9SP
Programmable Safety controllers g9sp G9SP compact Stand-Alone Programmable controller Stand-alone safety controller for small and mid-sized machinery Easy programming for complex safety control Three types
TECHNICAL DATASHEET Incremental Encoder RI 80-E
Incremental 30-45 hollow shaft Rugged mechanical design Unbreakable disc Integrated diagnostic system Wide voltage range DC 5-30 V Isolated shaft NUMBER OF PULSES 1024 / 2048 / 2500 / 4096 / 5000 / 10000
CONFIGURABLE SAFETY RELAYS
MSI-m/R, MSI-mx/Rx Configurable MSI Safety Relay with function for efficient material flow in a packaging application Special features Sequential or Parallel with automatic mode detection MSI-mx for separate
/ Our accessories complement all PV systems, simplify installation and ensure that the system meets the required safety standards.
56 / Accessories for inverters Accessories for inverters / Our accessories complement all PV systems, simplify installation and ensure that the system meets the required safety standards. FRONIUS STRING
Durant PGM. For Sales and Support, Contact Walker EMD Toll-free: (800) 876-4444 Tel: (203) 426-7700 Fax: (203) 426-7800 www.walkeremd.
Eclipse Series Digital Panel Meters Installation and Operation Manual Number 57700-900-05 Models: 5770X-40X - DC Volts 5770X-4X - AC Volts 5770X-42X - DC Amps 5770X-43X - AC Amps 5770X-44X - 5A AC 5770X-45X
2/8.10.01. These vacuum switches are used in measuring ranges between -1 and 0 bar.
CATALOGUE > Release 8.5 > Electronic vacuum switches Series SWM Electronic miniature vacuum switches Series SWM These vacuum switches are used in measuring ranges between -1 and 0 bar. Small dimension
How To Run An Nport I5000A Device Server
NPort IA5000A Series 1, 2, and 4-port serial device servers for industrial automation Enhanced surge protection for serial, LAN, and power 2 KV isolation for serial signals Rugged screw-type terminal blocks
Control Devices Catalogue. Control Devices. Preferred and Standard Products
Control Devices Catalogue Control Devices Preferred and Standard Products KOP.J Timer Electronic 22.5 mm Characteristics Mounting KOP.J 22.5 mm mono or multifunction high immunity to interference surface
Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S 4.230.1, GH Q631 0076 R0111. ABB i-bus EIB
, GH Q631 0076 R0111 2CDC 071 240 F0003 The Shutter Actuator Standard is used to control a maximum of four independent 230 VAC drives for positioning shutters, blinds, awnings and other hangings as well
IP40 or IP64 (EN 60529) Protection class housing. IP50 (IP65 optional) (EN 60529) Minimum length of mountig
Through hollow shaft Ø 5 bis 4 mm Outside diameter only 76 mm Easy installation by means of clamping ring front or rear Operating temperature up to 00 C Applications: motors, printing machines, lifts NUMBER
Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description
Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display
ACR120 Technical Specifications version 2.9 November 2005
Version 2.9 11-2005, Email: [email protected] Website: www.acs.com.hk ACR120 Contactless Reader/Writer 1.0 Introduction The ACR120 is a compact and cost-effective contactless reader and writer. It is developed
TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR
TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR TECHNICAL DATA CARATTERISTICHE MECCANICHE Housing Self-extinguishing plastic, UL 94 V0 Dimensions 48x48 mm DIN depth 98 mm Weight 225 g approx.
SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors. 40-300 mm background suppression
Advanced line of miniature Asian style of photoelectric sensors 4-3 background suppression.7 m proximity, 15 with narrow beam 4 m polarized retroreflective 3 m LASER through beam Standard 3-wire output
DS 600. A contact free flux gate based current measurement sensor 600A rms
DS 600 A contact free flux gate based current measurement sensor 600A rms DS 600 is member of the small housing sensor family. The family includes a 200A and a 600A version. 600A rms - 900A peak Maximum
1.44 kw Programmable DC Power Supplies XLN Series
Data sheet 1.44 kw Programmable DC Power Supplies XLN Series New Family of High Density System Power Supplies The B&K Precision XLN series are compact, programmable, single-output DC power supplies, suitable
LwLVision-USB 2.0. Installation Guide
LwLVision-USB 2.0 Installation Guide About this manual This manual has been carefully compiled and examined to the state-of-the-art. G&D neither explicitly nor implicitly takes guarantee or responsibility
PNOZsigma - Base units
PNOZsigma - Base units Register Login Sensors Control and Communication Electronic monitoring relays Safety Relays PNOZ X PNOZsigma PNOZelog PNOZmulti PNOZpower Configurable control systems Programmable
ABB i-bus EIB / KNX Analogue Input AE/S 4.2
Product Manual ABB i-bus EIB / KNX Analogue Input AE/S 4.2 Intelligent Installation Systems This manual describes the functionality of Analogue Input AE/S 4.2. Subject to changes and errors excepted. Exclusion
Speed Control Relays SX2
SX2 File 850 CONENS Description.....................................................Page General Information................................................ 2-3 SX2DV General Information...........................................
Manual Serial PCI Cards
Manual Serial PCI Cards W&T Models 13011, 13410 13411, 13610 13611, 13812 Version 1.4 Subject to error and alteration 37 01/2005 by Wiesemann & Theis GmbH Subject to errors and changes: Since we can make
Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800
Power-monitoring unit PowerLogic System Technical data sheet 2003 Power Meter Series 800 Function and characteristics PB100313 The PowerLogic Power Meter Series 800 offers all the high-performance measurement
Incremental Rotary Encoder E6B2
Incremental Rotary Encoder General-Purpose Rotary Encoder Withstands arge Shaft oads Wide variety of supply voltages and output forms Easy-to-adjust zero index (phase Z) with origin indicating function
Inductive Proximity Sensors
M12 Inductive Proximity Sensors Standard Length Mini's Extended Sensing 3 Wire DC 2 Wire DC 2 Wire AC (Wiring Schematic) 3 Wire DC PNP Normally Open (1) IMM32122C IMM35124C IMN32122C IMN35124C IMN32122M12
TECHNICAL DATASHEET Incremental Encoder RI 58-O / RI 58-T
Universal industry standard encoder Up to 40 000 steps with 0 000 pulses High signal accuracy Protection class up to IP67 Flexible due to many flange and configuration variants Suitable for high shock
MCB3101 (Class I) WiRobot Serial Bluetooth Wireless Module User Manual
MCB3101 (Class I) WiRobot Serial Bluetooth Wireless Module User Manual Version: 1.0.1 Dec. 2005 Table of Contents I. Introduction 2 II. Operations 2 II.1. Theory of Operation 2 II.2. Configuration (PC-PC
ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL
ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL INTRODUCTION... 2.. TECHNICAL DATA... 3 ACCESSORIES... 5. INSTALLATION... 7 OPERATION... 12. TECHNICAL INFORMATION... 13 MAINTENANCE... 14. CONFIGURATIONS...