GB Software handbook SOFTWARE

Size: px
Start display at page:

Download "GB Software handbook SOFTWARE"

Transcription

1 GB Software handbook SOFTWARE

2 Table of Contents CHAPTER 1 CHAPTER 2 LANDIRENZO OMEGAS SOFTWARE MAIN SCREEN 2.1 Main screen Main menu Function buttons Multilanguage panel Status bar 6 CHAPTER 3 LANDIRENZO OMEGAS SOFTWARE CONFIGURATION 3.1 Vehicle configuration Change gas Lambda (optional) Gas level Emissions Pressure Temperature Enter K Injectors Display Diagnosis Automatic calibration Change calibration Save current configuration Load new configuration Programming the control unit Update map sheets End program 23 2 LANDI RENZO S.p.A.

3 CHAPTER 4 CHAPTER 5 INSTALLATION SHEETS C SOFTWARE INSTALLATION 5.1 With Windows XP Professional and Windows 2000 Professional operating systems 25 CHAPTER 6 BASE SETTINGS 6.1 Programming for the first time 28 LANDI RENZO S.p.A. 3

4 CHAPTER 1 SOFTWARE LANDIRENZO OMEGAS The LANDIRENZO OMEGAS program enables technicians at LANDIRENZO retailers to work on the LANDIRENZO OMEGAS injection control units. Specifically, it is possible to program the gas control units with the vehicle archive data, and display and change some of the parameters on which the control unit acts. The program can be used with no in-depth knowledge of how a PC operates, apart from a basic knowledge of the Windows interface. The LANDIRENZO OMEGAS program requires one of the following operating systems: Windows 98 SE, Windows ME, Windows 2000 or Windows XP. At least version 5.5 of Internet Explorer must also be installed. The later version, Internet Explorer 6.0, is recommended. If a new version of the software is being installed, the old versions should be disinstalled completely and the new software installed from the new CD-ROMs. The new CDs also include a folder entitled EncPak IE containing a file entitled Install.htm. This file contains the correct links to other files on the CD that enable the Internet Explorer files needed for the control unit programming procedure to be installed on the various computers. The minimum PC specifications are: 486 processor, 8Mb RAM, SVGA 640X colour graphics card, CD ROM reader (or Internet connection), at least 10 Mb free on the hard disk (this last figure depends on the number of vehicles and information files present in the archive, since about 600 Kb are required for each vehicle information file). For optimal functionality, a system with a Pentium 133 or higher, 16 Mb of RAM and an SVGA 800X600 graphics card is recommended. To install the the LANDIRENZO OMEGAS Program: - execute setup.exe - or use autorun to install the program automatically. The installation program starts automatically press next (three times as requested), install and finish. The progress of the totally automatic installation is shown. The only information requested is the folder in which the program is to be installed. If no folder is specified the program will be installed in a folder entitled <PROGRAMMI\Landi Renzo\Landi Renzo Omegas. After completing the installation, double click on the LANDI RENZO OMEGAS icon on the desktop, or press Start\Programs\Landi Renzo\Landi Renzo Omegas. Before using LANDIRENZO OMEGAS check that Acrobat Reader 4.0 or a later version is installed on the PC: this program is needed to consult the vehicle information files. However, the Landi Renzo CD contains a copy of this program. 4 LANDI RENZO S.p.A.

5 CHAPTER 2 1 MAIN SCREENCHAPTER 2.1 MAIN SCREEN 2 3 The main screen shown in Fig. 1 appears every time the program is started. Its essential component elements are: 1. Main menu 2. Function buttons 3. Multilingual panel 4. Status bar 4 FIG MAIN MENU FIG. 2 The main menu contains all the program settings and commands. Specifically: 1 - FILE (fig. 2): contains the commands: OPEN CONFIGURATION.: opens files not present in the LPG or METHANE folder in the LR OMEGAS directory ; SAVE CONFIGURATION : saves files, including to folders other than the LPG or METHANE folder in the LR OMEGAS directory; PRINT CONFIGURATION: prints the pages in the F1 Vehicle Configuration menu ; PRINT CORRECTION prints the page of the F5 Change Configuration menu; ; PRINT DIAGNOSIS prints the page of the F3 Diagnosis menu; FITTING INSTRUCTIONS detailed explanation given in chapter 5; EXIT: closes the LANDIRENZO OMEGAS software; 2 - CONNECTION (fig. 3): includes the CONNECT and DISCONNECT commands to respectively connect and disconnect from the control unit; 3 - HELP (fig. 4): contains ABOUT..., a window showing the program identification data and copyright information. FIG. 3 LANDI RENZO S.p.A. 5

6 2.3 FUNCTION BUTTONS (FIG. 1 REF. 2) FIG. 4 The buttons in the centre of the screen enable program functions to be executed. They can be clicked on with the mouse, or the corresponding function key can be pressed. The functions are. F1 VEHICLE CONFIGURATION: this displays a page that can be used to set the correct input signals from the vehicle and the characteristic parameters of the gas system fitted to the vehicle. F2 DISPLAY: this displays a page showing all the fundamental parameters for the gas system to function correctly; F3 DIAGNOSIS: displays a page showing error messages. F4 AUTOMATIC CALIBRATION: accessing this menu activates an automatic procedure for vehicle calibration. F5 CHANGE CALIBRATION: menu used to optimise the calibration on a file created/present in the control unit. F6 SAVE CURRENT CONFIGURATION: menu used to save the current configuration present on the vehicle. F7 LOAD NEW CONFIGURATION: menu used to load files stored in the archive. F8 PROGRAM CONTROL UNIT: menu used to update the control unit software version. F9 UPDATE SHEETS AND MAPS: can be used to update the information sheets and maps present in the software. F10 EXIT: ends the program. 2.4 MULTILINGUAL PANEL (FIG. 1 REF. 3) The panel appears on the right of the window, and allows the user to select the language for all the written parts and messages of the program. This parameter is simple to use just press the button for the language desired and the whole program is INSTANTLY configured in the selected language. The operation can also be performed by right clicking anywhere on the window to display a quick menu containing the languages shown on the buttons in the multilanguage panel. 2.5 STATUS BAR (FIG. 1 REF. 4) The bar in the lower part of the window contains program status information. The bar is divided into 3 fields, showing, from left to right: 1 Whether or not the control unit is connected. 2 If the control unit is connected, the name of the file it contains. 3 The control unit software version. The status bar cannot be modified directly. 6 LANDI RENZO S.p.A.

7 CHAPTER 3 LANDIRENZO OMEGAS SOFTWARE CONFIGURATION The first time the LANDIRENZO OMEGAS program is used some parameters needed for the program to function correctly must be configured. They are: - Internet connection to be used (ONLY if an INTERNET connection is available). The first setting is performed directly inside the LANDIRENZO OMEGAS program. To select the Internet connection proceed as follows: 1) Select SETTINGS CONTROL PANEL INTERNET OPTIONS in the Windows Start menu. 2) Select CONNECTIONS Enable the option CONNECT TO THE INTERNET WHEN NECESSARY. A checkmark will appear next to the option. In the USE REMOTE ACCESS CONNECTION box, choose the connection you normally use to connect to your ISP. Confirm with OK. NOTE: if these settings have already been enabled you do not need to do anything. These settings, and the window sizes, are saved permanently in the memory even after the computer has been switched off. Every time the program is started the data saved previously will be reloaded. They are: - Language - Position and dimensions of main window. The program automatically searches for the serial port to which the serial cable used to program the LANDIRENZO OMEGAS control unit is connected VEHICLE CONFIGURATION Change gas FUEL TYPE: Used to set the fuel type: - METHANE - LPG 2 INJECTOR TYPE: Window showing the type of injector fitted on the vehicle. The wiring informs the control unit what type of injector is fitted, so if another model injector should be fitted and the file loaded presented piloting that is not compatible with the injector, the software would not allow the change to gas. It then provides an opportunity to change the piloting to make it compatible with the injector fitted. 18 FIG. 5 LANDI RENZO S.p.A. 7

8 3 ENGINE TYPE: Indicates the type of engine in the vehicle can be set to turbo engine or aspirated engine. 4 INJECTOR SIZE: This identifies the dimensions of the MED injector fitted. These days only medium size injectors are available, so this button is disabled. 5 ENGINE SIZE: Can be used to set the engine size of the motor vehicle, from a minimum of 900 cc to a maximum of 8000 cc. 6 REV SIGNAL TYPE: Used to set weak or standard signals. A WEAK signal must be selected if the input revs are from the ignition coil transistor piloting signal. The STANDARD option is used when the connection to the coil negative is used. If connection is to the rev counter than either option may be used although WEAK SIGNAL is preferable. 7 NUMBER OF CYLINDERS: The number of cylinders present in the transformed car must be set. The software accepts 3, 4 5, 6 or 8 cylinders. The window displays the possibility of setting 5, 6 or 8 cylinders only if an 8 cylinder control unit is connected. 8 IGNITION TYPE: The software allows the following parameters to be set: A Single coil B Dual coil C Rev counter This information is used by the control unit to correctly calculate the engine regime from the period read on the rev input. Select SINGLE COIL if the vehicle has a coil for each cylinder an the signal is taken from the o negative of the coil transistor pilot. Select DUAL COIL if the vehicle has a coil that pilots two cylinders and takes the o negative from the coil transistor pilot. Use the REV COUNTER option in all other cases. 9 TYPE OF CHANGE: Used to set the type of change to make: It can be set as: - in acceleration - in deceleration - start with gas 10 REV THRESHOLD FOR THE CHANGE: This is the minimum threshold that must be exceeded to permit the change from petrol to gas; it is set to a default value of 1600 rpm. It may be set to values from 0 to 3000 rpm. 11 WATER TEMPERATURE FOR THE CHANGE (if optional water temperature sensor installed): With the rev threshold for the change, this is the other parameter that must be fulfilled for the change from petrol to gas. It may be set to values between 40 C and 120 C. 8 LANDI RENZO S.p.A.

9 12 GAS TEMPERATURE FOR THE CHANGE: If set in page F5, this, with the rev threshold for the change and the water temperature for the change, is another parameter that must be fulfilled for the change from petrol to gas. It may be set to values between 30 C and 90 C. 13 DELAY IN CHANGE FROM PETROL TO GAS: (if optional water temperature sensor installed) When the multifunction relay is connected, the gas ECU reads the water temperature and sets the delay indicated. 14 DELAY IN CHANGE FROM PETROL TO GAS WITH GAS TEMPERATURE (if no temperature sensor installed): When the multifunction relay is connected, the gas ECU reads the water temperature and sets the delay indicated. 15 OVERLAP TIME: This is the time in which the petrol and gas fuel supplies overlap. It is set by default to 0 seconds, but can be increased up to 2 seconds. 16 ZERO CONTROL UNIT AND RETURN TO BASE PARAMETERS: When key 9 is pressed previously entered data (from 1 to 8) are changed and restored to the default values. Parameters 1, 4, 5 and 6 must be modified as indicated in line 10, with the multifunction relay disconnected and the switch off. If modifications are made without respecting the switch off condition, they will only be displayed, and will be lost the next time the control unit is connected/disconnected. 17 WARNING! ONLY CHANGE THE PARAMETERS IN RED WITH THE MULTIFUNCTION RELAY OFF AND THE SWITCH OFF 18 STATUS BAR: The following are indicated in the status bar, from left to right: A type of fuel being used; B number of engine revs; C gas injection time, petrol injection time; D engine water temperature, gas temperature and gas pressure; E Lamda voltage and rich (red) or lean (green) vehicle carburation during operation (if the sensor is connected). LANDI RENZO S.p.A. 9

10 3.1.2 Lambda (optional) TYPE OF LAMBDA SENSOR This is used to set the type of lambda sensor fitted on the vehicle for correct signal interpretation. The following values can be set: A Volt; B Volt; C Volt; D Volt. FIG. 6 2 NUMBER OF LAMBDA SENSORS Used to set when two lambda sensors are present, and to display their signals. Used to set when two lambda sensors are present, and to display their signals Gas level FIG GAS LEVEL SENSOR TYPE Used to enter the type of gas level sensor that has been installed. The following level indicators can be set: A - A.E.B.; B ohm; C - Landi Renzo; D - Not standard; E Inverted non standard. The standard predefined setting is the Landi Renzo sensor. Selecting the option NOT STANDARD or INVERTED NOT STANDARD the settings for the type of gas level sensor used can be customised by setting suitable thresholds. 2 AUTOMATIC RETURN TO PETROL (fig. 7 ref. 2) If the control has been activated two conditions are possible: Respectively - MAP sensor not present A - MAP sensor present and set B FIG. 8 A: if the MAP sensor is not present the switch back is controlled by the absolute pressure based on the references listed in the table shown in figure 6. In this case the injection time/absolute gas pressure string appears in the GAS LEVEL pages. When the absolute pressure rises for a precise injection time (fig. 7 ref. 4) below the absolute pressure reference entered (fig. 7 ref. 5) set for the time (fig. 7 ref. 3), the switch back to petrol is triggered automatically. WARNING: For METHANE turbo vehicles NEVER proceed to MAP connection and sensor parameter entry. 10 LANDI RENZO S.p.A.

11 B: if the MAP sensor is present, the change back is controlled by the differential pressure; in this case, however, the original vehicle signal must be parameterised chapter Emissions 1 2 This function may be useful for the emissions produced in case of abundant HCs injected when returning from cut-off (see Megane Scenic, which has a return to minimum from cut-off of around 1000 rpm, and thus a 140% enrichment entered for 40 injections prevents switching off) or if the engine exits from cutoff to a very low rev regime. FIG. 9 Setting: - % (fig. 9 ref. 1) > 100 enriches the number of injections set exiting from cut off (fig. 9 ref. 2). - % (fig. 9 ref. 1) < 100 makes lean the first the number of injections set exiting from cut off (fig. 9 ref. 2) Pressure 1 If the MAP sensor is not present select the parameter not present from the pull down menu. However, if the sensor is present the wire should be connected and present selected from the pull down menu (fig. 10 ref. 1). FIG. 10 LANDI RENZO S.p.A. 11

12 Key 3 is used to start a guided procedure to enter the parameters of the sensor: The first step is the possibility of proceeding taking into account the fact that all the data present previously have been lost. If the MAP sensor is not present select the parameter not present from the pull down menu. However, if the sensor is present the wire should be connected and present selected from the pull down menu (fig. 10 ref. 1). Once the first value has been acquired, the program requests that the engine revs are increased to 3000 rpm. FIG LANDI RENZO S.p.A.

13 Leave the engine at minimum. The software processes the acquired data and parameterises the sensor. FIG Temperature 1 - GAS TEMPERATURE SENSOR TYPE Identifies the type of gas sensor used. The 2K2 sensor is set by default. 2 - ENABLE CHANGE WITH GAS TEMPERATURE This change is set as enabled by default. FIG ENABLE CHANGE WITH WATER TEMPERATURE The control is enabled by default and cannot be disabled; the change is only possible if the condition of T water greater than temperature set in page F1 gas change (Fig. 5 point 11) has been met. If no water sensor is fitted this control is ignored by the software. LANDI RENZO S.p.A. 13

14 4 USE VEHICLE ENGINE TEMPERATURE SENSOR To use the original engine temperature sensor of the car, the signal can be parameterised using a hand tester and constructing the Temperature/Voltage characteristics of the sensor by points. FIG ENTER K This is the main carburation map. The three main variables are: - RPM on the abscissa - Tinj petrol on the ordinate - K coefficient in the cells 1 2 The chain of calculation of the Tinj gas values is: Tinj_gas = (Tinj_petrol - Tdead_petrol) * K1(Tinj_petrol, revs) * K2(Pressure) *K3(Temp_water) * K4(Temp_gas) + Tdead_gas FIG. 15 where: Tinj_petrol: petrol injection time. Tdead_benz: petrol injector dead time. K1(Tinj_petrol, revs): map K coefficient. K2(Pressure):pressure compensation.k3(temp_water): water temperature compensation. K4(Temp_gas): gas temperature compensation. Tdead_gas: gas injector dead time. The gas injector dead time and the petrol dead time are two characteristic parameters of the corresponding injectors and are used to compensation the transitory openings and closings of the injectors. As can be seen in Fig. 12, they differ depending on whether they concern main injections (point 1), or to extra injections (point 2). FIG. 16 By changing the K COEFFICIENT MAP CELL CENTRES the following cell centres may be modified: - RPM (from 0 tp 8000)- RPM (from 0 to 8000) - Tinj petrol (from 0 tp 40 ms. 14 LANDI RENZO S.p.A.

15 FIG CALIBRATION PROCEDURE The objective is to ensure that the petrol does not change the related Tinj in the change from petrol to gas, and the phases to follow to obtain good carburation are: 3 - click on start/finish calibration 1 (so that the switch control occurs automatically when button 2 is pressed); - go to a precise vehicle functioning point characterised 2 by a specific cell of the map above (E.g RPM, Tinj petrol 4.5 ms); - allow the petrol injection time to stabilise then click button 2; the vehicle will change to gas; - evaluate the percentage variation in the petrol injection time during gas functioning compared to the petrol injection time during petrol functioning by observing bar 3; - if the space bar assumes high percentage values this means that the petrol control unit increases the injection times during operation on gas, i.e. the vehicle is lean while operating on gas and therefore the K coefficient of the cell in which we are located must be increased; if the space bar assumes low percentage values this means that the petrol control unit decreases the injection times while operating on gas, i.e. that the vehicle is rich and therefore the K coefficient of the cell in which we are located must be decreased. Variations of 2% in the petrol/gas change are considered acceptable. N.B.: while operating on petrol or on gas, the percentage bar (point 3) loses all significance. If you try to exit the calibration before it has been completed, the system will warn that you need to close the procedure to be able to continue. FIG. 18 LANDI RENZO S.p.A. 15

16 3.1.8 Injectors Some special characteristics of the injector and its piloting are shown in this page MAX 12 V CURRENT TIME (Tmax) This is the time for which 12V is supplied to the injector. 2 MAINTENANCE CURRENT (Cm) This is the current supplied to the injector in the maintenance phase. 3 INJECTOR IMPEDANCE This is the resistance of the injector. FIG. 19 Current Tmax 4 MINIMUM GAS INJECTOR OPENING TIME If the calculation of the Tinj gas supplies a value lower than this minimum time, the system uses the set value as minimum time. 5 MINIMUM EXTRA GAS INJECTIONS OPENING TIME As point 4, applied to the extra injections. Cm Tj Time DISPLAY This command allows all the significant signals the gas control unit works with to be displayed on one screen. A brief description of the information displayed is given below: 1 STATUS DISPLAY This shows, from left to right: A Multifunction relay; B Cut-off; C - Gas; D - Petrol. Active status is indicated by the red LED, and inactive status by green. FIG PRESSURE Displays the pressure assumed by the gas in bars. 3 INJECTION TIME A - Gas Injection time used by the gas injectors. B - Petrol. Petrol injection time read by the LANDIRENZO OMEGAS control unit through the injector cut-off wiring. 16 LANDI RENZO S.p.A.

17 4 - WATER TEMPERATURE, GAS TEMPERATURE GAS, VOLTAGE FOR GAS INJECTORS A Water temperature Provides information about the water temperature read by the sensor applied to the T inserted in the engine cooling water circuit at the entrance to the reduction unit. B Gas temperature Provides information about the gas temperature read by the sensor applied to the injector rail. C Voltage for gas injectors Indicates the gas injector supply voltage. 5 - LAMBDA SENSOR This is the value in volts supplied by the Lambda sensor (if connected). 6 - EXIT To exit from the page displayed. 3.3 DIAGNOSIS The functioning diagnosis page displays any malfunctioning of the components or the system that might occur while operating on gas. If an error message is displayed, it can be zeroed after the problem has been resolved by pressing button 1. The failures that can be detected are: DIAGNOSIS: GAS INJECTORS DIAGNOSIS When operating on gas an error is reported on an injector when open-load or shorts occur on the coil of an injector for a certain number of injections (10). FIG. 21 DIAGNOSIS: LOW PRESSURE When operating on gas an error is reported if the pressure reading stays at a level that is: - less than 0.4 bars for aspirated engines and 1 bar for turbo engines, on LPG - less than 1.54 bars for aspirated engines and 2.6 bar for turbo engines, on Methane for a certain period of time (low pressure time for return, set in Tools on the Gas Level page) while at the same time the gas level is not reserve. DIAGNOSIS: HIGH PRESSURE When operating on gas an error is reported if the pressure reading stays at a level that is: - greater than 1.4 bars for aspirated engines and 2.85 bar for turbo engines, on LPG - greater than 2.5 bars for aspirated engines and 4.1 bar for turbo engines, on Methane for a certain period of time (5 seconds). DIAGNOSIS: SAFETY RELAY CONTROL UNIT SELF DIAGNOSIS An error is reported if a voltage over 6V is detected downstream the relay for longer than 150 seconds in the absence of the multifunction relay (and therefore with the relay disconnected). This situation corresponds to a jammed relay. A diagnostic error is also reported if a voltage of less than 6V is read for 5 seconds downstream of the relay in the presence of revs. LANDI RENZO S.p.A. 17

18 DIAGNOSIS: SYSTEM SOLENOID VALVES Shorts or opens on the coils of the gas solenoid valves can be diagnosed when operating on gas. Bearing in mind that the two solenoid valves are connected in parallel on the same contact, the only control inherent to the piloting output (reduction unit solenoid valve control) must be enabled. The fault is reported when the measured current absorption is not within work range for 5 seconds. DIAGNOSIS: PETROL INJECTORS (or, rather, DISCONNECT INJECTORS STAGE) When operating on gas an error is reported when no petrol injectors are reported on any channel of the injector disconnection unit for a certain period of time (8 seconds). Obviously the vehicle must not be in cut-off and this check must only be performed if the revs are between 650 and 1000 (minimum zone, where the petrol control unit may be presumed not to operate its injectors with particularly strange strategies), to avoid strange conditions of partialised petrol injections. DIAGNOSIS: GAS TEMPERATURE Can only be activated if enable change with gas temperature has been checked in the Temperature page from the Tool menu. Possibility of detection when operating on gas: - sensor disconnected: if an analog reading of a reference corresponding to absence of the temperature sensor occurs continuously for 10 seconds. temperature too low: temperature lower than a value set on the diagnosis page is read for 10 seconds. - temperature too high: a temperature higher than a value set on the diagnosis page is read for 10 seconds. DIAGNOSIS: WATER TEMPERATURE Can only be activated if enable change with water temperature has been checked in the Temperature page from the Tool menu. Possibility of detection when operating on gas: - sensor disconnected: if an analog reading of a reference corresponding to absence of the temperature sensor occurs continuously for 10 seconds. - temperature too low: a temperature lower than a value set on the diagnosis page is read for 10 seconds. - temperature too high: a temperature higher than a value set on the diagnosis page is read for 10 seconds. Counters showing the number of hours of operation of the vehicle on petrol and on gas are also displayed on this page; these can be zeroed by pressing button 2. DIAGNOSIS: PETROL INJECTORS The control unit checks that the injector disconnection unit is correctly connected. In practice, depending on the number of cylinders, the control unit must wait for activation of some inputs. This control is only enabled at low revs (between 650 and 1000, where no complete or partialised cut-off strategies should intervene): if no type of transition is observed for 8 seconds (a period that is perhaps too long, but which is maintained deliberately high to avoid contra-indications) on a reading channel, an error is diagnosed on the corresponding cylinder. 18 LANDI RENZO S.p.A.

19 3.4 AUTOMATIC CALIBRATION 1 This procedure allows the operator to calibrate the vehicle mapping very quickly, thus obtained good vehicle handling. To proceed to automapping a water temperature threshold set at 50 C must be exceeded. If the procedure is attempted when this condition has not been met message 1 will appear, as shown in the figure. Fig. 22 If the temperature is higher than 50 C, autocalibration starts when enter is pressed. The program requires the revs to be stabilised at 3000 rpm. Fig. 23 The software automatically runs petrol-gas changes to scale the two injectors and thus obtain a correct carburation map. During these continual petrol gas changes it is important to keep the accelerator pedal steady to ensure that the system does not become unstable, increasing the time taken for auto mapping. Fig. 24 LANDI RENZO S.p.A. 19

20 Once correct mapping has been obtained the software performs a series of validation tests. Fig If the outcome of these tests is positive the message Autocalibrationterminated correctly appears. 1 WARNING: Exit the program using the EXIT key (1); this will ensure that the calibration performed will be correctly downloaded into the control unit. Always use the guide keys to exit screens, and NEVER use key 2 unless in extreme cases, such as program locked. Always use the guide keys to exit screens. Fig LANDI RENZO S.p.A.

21 3.5 CHANGE CALIBRATION 7 Additional functionality that allows the created/downloaded map present in the control unit to be refined. While operating on gas the box corresponding to the current work zone will light up in red. A timely correction can be made in each of the sixteen cells corresponding to the sixteen possible operating zones of the vehicle. The increase zone (PgUp) (4) or decrease zone (PgDn) (5) keys are used to increase or decrease the percentage correction. To perform a complete diagnosis of the vehicle it may be useful to use: Fig scantool cod connection of the lambda sensor. The page also shows: 1 Fuel being used 2 Petrol injection times 3 Lambda sensor voltage 4 - PgUp 5 - PgDn 6 - Exit. WARNING: Close the program using the EXIT key (6); this will ensure that the calibration performed will be correctly downloaded into the control unit. Always use the guide keys to exit screens, and NEVER use key 7 unless in extreme cases, such as program not responding. 3.6 SAVE CURRENT CONFIGURATION Fig. 28 Accessing SAVE CURRENT CONFIGURATION provides a possibility of saving the 3,4 cylinder or 5,6 or 8 cylinder file in the folder corresponding to the type of fuel being used. The program recognises the type of control unit connected and automatically saves the corresponding file in the 3,4 cylinder folder or the 5, 6 or 8 cylinder folder. The type of fuel chosen in the CHANGE GAS page (paragraph ) will determine that the METHANE file is saved in the corresponding METHANE folder or that the LPG file is saved in the corresponding LPG folder. The METHANE and LPG folders are structured with an archive on the left of the screen and are organised hierarchically in a three level tree. This means that to find a vehicle model the user must move through the tree selecting in sequence the right branch from those available. The first level corresponds to the type of fuel being used, and is automatically managed by the software once the type of fuel has been set in the F1 CHANGE GAS page in F1 VEHICLE CONFIGURATION. The second level corresponds to the vehicle manufacturers, listed alphabetically, and the branch corresponding to the manufacturer in question must be expanded (RIGHT ARROW or ENTER key). LANDI RENZO S.p.A. 21

22 Fig. 29 The third and last level corresponds to the vehicle models. In this case the branch cannot be expanded any more, the user has only to select the model using the UP/DOWN ARROWS or the mouse. If the wrong branch has been expanded, it can be compressed by pressing the ENTER or LEFT ARROW key, clicking the - sign, or by double clicking on the branch. 3.7 LOAD NEW CONFIGURATION Accessing LOAD CURRENT CONFIGURATION allows the user to load the 3,4 cylinder or 5,6 or 8 cylinder file in the gas control unit depending on the type of fuel being used. The program recognises the type of control unit connected and automatically selects the corresponding file in the 3,4 cylinder folder or the 5, 6 or 8 cylinder folder. The type of fuel chosen in the CHANGE GAS page (paragraph ) will determine that the METHANE file is loaded from the corresponding METHANE folder or that the LPG file is loaded from the corresponding LPG folder. The METHANE and LPG folders are structured with an archive on the left of the screen and are organised hierarchically in a three level tree. This means that to find vehicle model the user must move through the tree selecting in sequence the right branch from those available. The first level corresponds to the type of fuel being used, and is automatically managed by the software once the type of fuel has been set in the F1 CHANGE GAS page in F1 VEHICLE CONFIGURATION. The second level corresponds to the vehicle manufacturers, listed alphabetically, and the branch corresponding to the manufacturer in question must be expanded (RIGHT ARROW or ENTER key). The third and last level corresponds to the vehicle models. In this case the branch cannot be expanded any more, the user has only to select the model using the UP/DOWN ARROWS or the mouse. If the wrong branch has been expanded, it can be compressed by pressing the ENTER or LEFT ARROW key, clicking the - sign, or by double clicking on the branch. 22 LANDI RENZO S.p.A.

23 3.8 PROGRAMMING THE CONTROL UNIT Accessing the CONTROL UNIT PROGRAMMING menu allows the user to update the control unit software. Pressing F8 accesses the screen shown above and the version of the firmware to download to the control unit version can be selected from those present. The 3-4 cylinder or cylinder control unit version can also be selected (1). Fig. 30 During the updating phase, the software loads the data present in the control unit, updates them and downloads them to the control unit. 3.9 UPDATE MAP CARDS This function allows files and cards in the archive in the software to be updated. Fig. 31 The update can be performed: - from a floppy disk - from a CD- ROM - by specifying a pathway Fig END PROGRAM To end the program press the EXC key in the main screen. If the control unit is connected, it is automatically disconnected. LANDI RENZO S.p.A. 23

24 CHAPTER 4 INSTALLATION SHEETSCHAPTER The installation sheets present in the software associated with the calibration files can be displayed by accessing fitting instructions from the file menu. Fig LANDI RENZO S.p.A.

25 CHAPTER 5 C SOFTWARE INSTALLATION 5.1 WITH WINDOWS XP PROFESSIONAL AND WINDOWS 2000 PROFESSIONAL OPERATING SYSTEMS On Windows XP with a user that is not the administrator the drivers of the hardware keys are not installed and thus when booted the program starts at installer level (fig. 34) (it cannot find the hardware key, even if it is present). Fig. 34 To be able to use the program completely the user must: open the program and open Help About two new subpages will be displayed, one with the activation code (fig. 36), to send to Landi, and another with an empty space to enter the return code (fig. 35). Fig. 35 Fig. 36 LANDI RENZO S.p.A. 25

26 To activate the product, enter the code and press the Register product button (figs ), then close down and restart the program, which this time will start properly (fig. 39). Fig. 37 Fig. 38 Returning to the About menu, only the product code and additional information about the customer that has been inserted into the code generated by Landi will now be visible (figs ). Fig LANDI RENZO S.p.A.

27 Fig. 40 LANDI RENZO S.p.A. 27

28 CHAPTER 6 BASE SETTINGS CHAPTER 6.1 PROGRAMMING FOR THE FIRST TIME Programming the LANDIRENZO OMEGAS control unit for the first time must start, once the PC is connected to the control unit, with the entry of a series of data used to recognise certain characteristic parameters of the vehicle to calibrate. The parameters are: - type of fuel (enter with multifunction relay off). - engine size - type of rev signal (enter with multifunction relay off). - number of cylinders (enter with multifunction relay off). - type of ignition (enter with multifunction relay off). - rev threshold for the change - water temperature for the change When the program is opened all these parameters will be set to the default values, but must be customised according to the vehicle to be calibrated. After entering this data, proceed to AUTOMATIC CALIBRATION (paragraph 3.4). If connection to the control unit is difficult, this might be because it contains no control unit software. This program can be downloaded following the procedure described in paragraph 3.8 PROGRAMMING THE CONTROL UNIT. 28 LANDI RENZO S.p.A.

29 /0 lpg and ngv system via Nobel, Corte Tegge Cavriago (RE) Italia Tel Fax info@landi.it LANDI RENZO S.p.A. 29

PC SERIAL INTERFACE FOR LAMBDA GAS CONTROL LGC-700

PC SERIAL INTERFACE FOR LAMBDA GAS CONTROL LGC-700 PC SERIAL INTERFACE FOR LAMBDA GAS CONTROL LGC-700 INDEX 1- Introduction 2- AGI-PRO Program Set-up 3- AGI-PRO Program Use 3.1- Interface Link 3.2- How Start AGI-PRO program 3.2-1. Page MONITOR 3.2-2. Page

More information

CashFlow Programming Module CPM

CashFlow Programming Module CPM CashFlow Programming Module CPM Installation & User Guide GB REV G4 08/08/2006 Table of Content Table of Content... 2 CashFlow Programming Module (CPM)... 4 What is a CPM?... 4 CPM Identification... 4

More information

Transmitter Interface Program

Transmitter Interface Program Transmitter Interface Program Operational Manual Version 3.0.4 1 Overview The transmitter interface software allows you to adjust configuration settings of your Max solid state transmitters. The following

More information

Via Raffaello,33/A - 42100 Reggio Emilia Italia Tel +39 0522.514.461 Fax +39 0522 514469 - E-mail: aftersales@landi-gas.

Via Raffaello,33/A - 42100 Reggio Emilia Italia Tel +39 0522.514.461 Fax +39 0522 514469 - E-mail: aftersales@landi-gas. Trouble Shooting Solving problems with LSI-NSI software Update to version 2.1.0 1/14 Rev.0 2/14 Rev.0 CONTENTS 1.1. Switching from petrol to gas PAGE 4 1.2. Drop at medium-high speeds PAGE 5 1.3. Functioning

More information

LT1 Tune Kit Quick Start Guide

LT1 Tune Kit Quick Start Guide LT1 Tune Kit Quick Start Guide Revision D Page 1 Table of Contents Introduction... 3 Minimum PC Requirements... 3 Program Installation... 3 Registering the Program... 4 Installing the USB/ALDL Interface

More information

SA-9600 Surface Area Software Manual

SA-9600 Surface Area Software Manual SA-9600 Surface Area Software Manual Version 4.0 Introduction The operation and data Presentation of the SA-9600 Surface Area analyzer is performed using a Microsoft Windows based software package. The

More information

InfplusWin OPERATING MANUAL

InfplusWin OPERATING MANUAL InfplusWin OPERATING MANUAL Edition: October 2010. Vers. 1.70 ASSEMBLAD - Technical office - Automotive Division Inf-Win170ManGB GB 1 Index 1 INFPLUS-WIN SOFTWARE...3 1.1 INSTALLATION...3 2 INFPLUS-WIN

More information

Quick Start Guide RIVA/Athena Sea-Doo ECU

Quick Start Guide RIVA/Athena Sea-Doo ECU Quick Start Guide RIVA/Athena Sea-Doo ECU PART# - RS11891-ECU-DC APPLICATION(S): Sea-Doo 260/255/215hp icontrol Models RIVA/Athena ECU Manager Web Site: www.rivaathena.com NOTE: YOU MUST PERFORM PHYSICAL

More information

F453. TiF453. User guide 10/11-01 PC

F453. TiF453. User guide 10/11-01 PC F453 TiF453 User guide 10/11-01 PC 2 TiF453 User guide Contents 1. Hardware and Software requirements 4 2. Installation 4 1.1 Minimum Hardware requirements 4 1.2 Minimum Software requirements 4 3. Fundamental

More information

SOFTWARE INSTALLATION INSTRUCTIONS

SOFTWARE INSTALLATION INSTRUCTIONS AUDITGARD LGA Electronic Combination Lock SOFTWARE INSTALLATION INSTRUCTIONS Implementation Package The AuditGard Software implementation package includes: 707013 AuditGard Software Install CD 42145 Programming/Audit

More information

HANDBOOK on SEQUENT 24

HANDBOOK on SEQUENT 24 HANDBOOK on SEQUENT 24 INDEX 0 - Introduction 0.1 - What is SEQUENT 24? 0.2 - Main differences with the previous SEQUENT systems 1 - Understanding the SEQUENT 24 system 1.1 - SEQUENT 24 ECU 1.2 - Changeover

More information

COMBOGARDPRO. 39E Electronic Combination Lock SOFTWARE INSTALLATION INSTRUCTIONS

COMBOGARDPRO. 39E Electronic Combination Lock SOFTWARE INSTALLATION INSTRUCTIONS COMBOGARDPRO 39E Electronic Combination Lock SOFTWARE INSTALLATION INSTRUCTIONS IMPLEMENTATION PACKAGE The ComboGard Pro Software implementation package includes: 707012 ComboGard Pro Software Install

More information

Parts List. Navigation

Parts List. Navigation Parts List quantity description 1 LCD-200 Display 1 LCD-200 Display cable 1 CD-ROM 2 dual lock or velcro 1 1GB SD card (optional) 1 CAN termination plug Navigation Main Menu Begin Log/Stop Log page 4 Log

More information

Electronic Power Control

Electronic Power Control Service. Self-Study Programme 210 Electronic Power Control Design and Function With the Electronic Power Control system, the throttle valve is actuated only by an electric motor. This eliminates the need

More information

ROM ACCESS CONTROL USER S MANUAL

ROM ACCESS CONTROL USER S MANUAL ROM ACCESS CONTROL USER S MANUAL Manual Software Pro-Access Page: 1 PRO-ACCESS SOFTWARE GUIDE PRO-ACCESS SOFTWARE GUIDE 1 0. INTRODUCTION 3 1. INSTALLIG THE SOFTWARE 4 2. SOFTWARE OPERATORS AND COMPETENCIES.

More information

File Management Utility. T u t o r i a l

File Management Utility. T u t o r i a l File Management Utility T u t o r i a l Contents System Requirements... 2 Preparing Files for Transfer to GlobalMark... 2 Application Launch... 2 Printer Setup... 2 Communication Status... 4 Communication

More information

DeviceNet Bus Software Help for Programming an Allen Bradley Control System

DeviceNet Bus Software Help for Programming an Allen Bradley Control System FBP FieldBusPlug V7 DeviceNet Bus Software Help for Programming an Allen Bradley Control System DeviceNet Software Help for Programming an Allen Bradley Control System Contents Page General Purpose...

More information

Back Office Recorder Dig04 Installation Guide

Back Office Recorder Dig04 Installation Guide Back Office Recorder Dig04 Installation Guide Comvurgent Limited Date & Issue: Issue 3 Dec 2005 Comvurgent www.comvurgent.com Downloads Available at www.usbcallrecord.com UK Office +44 (0) 7950 916362

More information

1.0. User s Guide & Manual USB 2.0 FLASH DRIVE

1.0. User s Guide & Manual USB 2.0 FLASH DRIVE 1.0 USB 2.0 FLASH DRIVE User s Guide & Manual Index Introduction 1 CHAPTER1 Features & Specifications 2 CHAPTER2 System Requirements 4 CHAPTER3 Getting Started Installation of the Windows 98SE Driver 5

More information

TX3 Series TELEPHONE ACCESS SYSTEMS. Configurator Quick Start. Version 2.2 Mircom Copyright 2014 LT-973

TX3 Series TELEPHONE ACCESS SYSTEMS. Configurator Quick Start. Version 2.2 Mircom Copyright 2014 LT-973 TX3 Series TELEPHONE ACCESS SYSTEMS Configurator Quick Start Version 2.2 Mircom Copyright 2014 LT-973 Copyright 2014 Mircom Inc. All rights reserved. Mircom Configurator Software Guide v.2.2 for Windows

More information

RGK60 RGK50 RGAM10 RGAM20 RGAM4 Generator set control units

RGK60 RGK50 RGAM10 RGAM20 RGAM4 Generator set control units I123 GB 1207 RGK60 RGK50 RGAM10 RGAM20 RGAM4 Generator set control units CUSTOMIZATION SOFTWARE MANUAL List of contents Introduction... 2 Main window... 3 Device model selection... 3 Transmission of data

More information

Technical Manual Calibration Software for the Alisei Injection System (Installer Version ZAV009)

Technical Manual Calibration Software for the Alisei Injection System (Installer Version ZAV009) Injection System del 06/10/09 Document Technical ID: MT_IS_SWI-003-I Rev. Date Review n. Issued by Reviewed/Approval 0 19/12/2006 First Issue 1 26/03/2007 Second Issue 2 11/10/2007 Third Issue 3 16/02/2009

More information

Page 1 S5.5 Monitoring Software Manual Rev 1.2 for Software Ver 1.0

Page 1 S5.5 Monitoring Software Manual Rev 1.2 for Software Ver 1.0 Trantec S5.5 Monitoring Software Manual Initial Setup Minimum PC Requirements 1.6 GHz CPU, 256 MB Memory, 1 available USB port, Windows XP Recommended PC >2.0 GHz CPU, 512 MB (XP) 1 GB (Vista) memory,

More information

SOFTWARE GUIDE PM1405 DATA PROCESSING SOFTWARE

SOFTWARE GUIDE PM1405 DATA PROCESSING SOFTWARE SOFTWARE GUIDE PM1405 DATA PROCESSING SOFTWARE Equipment Software Manufacturer Survey meter РМ1405 "РМ1405 Software" Polimaster Copyright Polimaster 2015. All rights reserved. According Copyright protection

More information

Connection and Programming Manual for

Connection and Programming Manual for Connection and Programming Manual for controller (also available in the diagnostic software and at www.ac.com.pl) ver. 2.8.9 2013-07-09 Manufacturer: AC Spółka Akcyjna. 15-181 Białystok, ul. 42 Pułku Piechoty

More information

Installing the Microsoft Network Driver Interface

Installing the Microsoft Network Driver Interface Installing the Microsoft Network Driver Interface Overview This guide explains how to install the PictureTel Live200 Microsoft Network Driver Interface (NDIS) software you have downloaded from PictureTel's

More information

CMS Central Monitoring System

CMS Central Monitoring System General In This Section CMS for Windows CMS Hardware CMS Functional Spec Relational Database Monitoring Interface Communication Network CMS Central Monitoring System General CMS Central Monitoring System

More information

Installing the Gerber P2C Plotter USB Driver

Installing the Gerber P2C Plotter USB Driver Installing the Gerber P2C Plotter USB Driver 1 You can install a Gerber P2C plotter using a USB connection and communicate with it using compatible design software. The following procedures describe installing

More information

PLUS TV ANALOG USB STICK Installation Manual

PLUS TV ANALOG USB STICK Installation Manual PLUS TV ANALOG USB STICK Installation Manual Contents V1.2 Chapter 1 : PLUS TV ANALOG USB STICK Hardware Installation...2 1.1 Package Contents...2 1.2 System Requirements...2 1.3 Hardware Installation...2

More information

WA Manager Alarming System Management Software Windows 98, NT, XP, 2000 User Guide

WA Manager Alarming System Management Software Windows 98, NT, XP, 2000 User Guide WA Manager Alarming System Management Software Windows 98, NT, XP, 2000 User Guide Version 2.1, 4/2010 Disclaimer While every effort has been made to ensure that the information in this guide is accurate

More information

Productivity Software Features

Productivity Software Features O P E R A T I O N S A N D P R O C E D U R E S F O R T H E P R O D U C T I V I T Y S O F T W A R E Productivity Software Features Remote CS-230 calibration and set-up on a personal computer. CS-230 calibration

More information

well as pulses from a magnetic driveshaft sensor or a magnetic speedometer cable sensor.

well as pulses from a magnetic driveshaft sensor or a magnetic speedometer cable sensor. 1. Overview The Maximizer 4 progressive nitrous controller operates one or two separate stages of nitrous based on either time, RPM, MPH, throttle percentage or boost pressure. Whether your engine is naturally

More information

AXIS Camera Station Quick Installation Guide

AXIS Camera Station Quick Installation Guide AXIS Camera Station Quick Installation Guide Copyright Axis Communications AB April 2005 Rev. 3.5 Part Number 23997 1 Table of Contents Regulatory Information.................................. 3 AXIS Camera

More information

QUICK START GUIDE 199R10546

QUICK START GUIDE 199R10546 QUICK START GUIDE 199R10546 1.0 Overview This contains detailed information on how to use Holley EFI software and perform tuning that is included within the software itself. Once you load the software,

More information

DataLINE Data Retrieval

DataLINE Data Retrieval Container Refrigeration INSTALLATION GUIDE for DataLINE Data Retrieval 62 10628 Rev B INSTALLATION GUIDE CONTAINER REFRIGERATION UNIT DataLINE Data Retrieval CONTENTS Paragraph Number Page 1. Introduction...

More information

Quick Start Using DASYLab with your Measurement Computing USB device

Quick Start Using DASYLab with your Measurement Computing USB device Quick Start Using DASYLab with your Measurement Computing USB device Thank you for purchasing a USB data acquisition device from Measurement Computing Corporation (MCC). This Quick Start document contains

More information

345020-345021. TiIrydeTouchPhone. User guide 10/11-01 PC

345020-345021. TiIrydeTouchPhone. User guide 10/11-01 PC 345020-345021 TiIrydeTouchPhone User guide 10/11-01 PC 2 TiIrydeTouchPhone User guide Contents 1. Hardware and Software requirements 4 1.1 Minimum Hardware requirements 4 1.2 Minimum Software requirements

More information

Software Installation Procedure (MS Windows)

Software Installation Procedure (MS Windows) Software Installation Procedure (MS Windows) E9970-96005 Rev. A 02/2004 (3070 05.30p 0603 WN) In this guide... Introduction, 1 Agilent 3070 Tech Support Web Site, 2 Time for Installation, 2 PC Specifications

More information

QUICK START GUIDE. SG2 Client - Programming Software SG2 Series Programmable Logic Relay

QUICK START GUIDE. SG2 Client - Programming Software SG2 Series Programmable Logic Relay QUICK START GUIDE SG2 Client - Programming Software SG2 Series Programmable Logic Relay SG2 Client Programming Software T he SG2 Client software is the program editor for the SG2 Series Programmable Logic

More information

The following pages will help you to solve issues linked to the installation and first use of the Wintech Manager software and Wintech USB computer.

The following pages will help you to solve issues linked to the installation and first use of the Wintech Manager software and Wintech USB computer. WINTECH MANAGER FAQ The purpose of this document is not to replace the complete user guide delivered on the Wintech Manager s CD. Most of the common question you may have about the use of the Wintech Manager

More information

Automation and Systems Technology. LABCONTROL TFM/TPM User Manual TroxMConnect Operating Software. 1. Introduction 1. 2. Software Installation 2

Automation and Systems Technology. LABCONTROL TFM/TPM User Manual TroxMConnect Operating Software. 1. Introduction 1. 2. Software Installation 2 1. Introduction 1 2. Software Installation 2 2.1 System Requirements 2 2.2 TroxMConnect Installation 2 2.3 Connection to the PC 3 3. TroxMConnect Description 4 3.1 Starting the Software 4 3.2 Layout 4

More information

StrikeRisk v6.0 IEC/EN 62305-2 Risk Management Software Getting Started

StrikeRisk v6.0 IEC/EN 62305-2 Risk Management Software Getting Started StrikeRisk v6.0 IEC/EN 62305-2 Risk Management Software Getting Started Contents StrikeRisk v6.0 Introduction 1/1 1 Installing StrikeRisk System requirements Installing StrikeRisk Installation troubleshooting

More information

USER MANUAL OPERATION AND USE OF CAR WITH. Diego G3 / NEVO SEQUENTIAL GAS INJECTION SYSTEM

USER MANUAL OPERATION AND USE OF CAR WITH. Diego G3 / NEVO SEQUENTIAL GAS INJECTION SYSTEM USER MANUAL OPERATION AND USE OF CAR WITH Diego G3 / NEVO SEQUENTIAL GAS INJECTION SYSTEM Page 2 z 7 Table of contents 1. STARTING THE ENGINE... 3 2. CONTROL PANEL... 3 2.1 Indication of the current level

More information

DESCRIPTION. DTC P0351 Ignition Coil "A" Primary / Secondary Circuit. DTC P0352 Ignition Coil "B" Primary / Secondary Circuit

DESCRIPTION. DTC P0351 Ignition Coil A Primary / Secondary Circuit. DTC P0352 Ignition Coil B Primary / Secondary Circuit 1 of 10 6/4/2012 10:38 PM Last Modified: 3-27-2012 6.4 C From: 201203 Model Year: 2013 Model: FR-S Doc ID: RM000000XH40PUX Title: FA20 ENGINE CONTROL: SFI SYSTEM: P0351-P0354: Ignition Coil "A" Primary

More information

ASTROW HR. Installation & Operation & Programming MANUAL

ASTROW HR. Installation & Operation & Programming MANUAL ASTROW HR Installation & Operation & Programming MANUAL 2007 A.S.E. R&D EUROPE. Printed in Belgium. All rights reserved. NOTICE Information in this document is subject to change without notice and does

More information

DVB-T PI610 Installation Manual

DVB-T PI610 Installation Manual DVB-T PI610 Installation Manual Contents V1.0 Chapter 1 : DVB-T PI610 Card Hardware Installation...2 1.1 Package Contents...2 1.2 System Requirements...2 1.3 Hardware Installation...2 Chapter 2 : DVB-T

More information

Basic Operation and Function of the MSD Pro Data Plus. Best viewed in printed form. Click on File>Print.

Basic Operation and Function of the MSD Pro Data Plus. Best viewed in printed form. Click on File>Print. Basic Operation and Function of the MSD Pro Data Plus Best viewed in printed form. Click on File>Print. Begin by double clicking the left mouse button on the MSD GraphView on your desktop. When Graph View

More information

Motorola Phone Tools. Quick Start

Motorola Phone Tools. Quick Start Motorola Phone Tools Quick Start Contents Minimum Requirements...2 Before Installing Motorola Phone Tools...3 Installing Motorola Phone Tools...4 Mobile Device Installation and Configuration...5 Online

More information

TANDBERG MANAGEMENT SUITE 10.0

TANDBERG MANAGEMENT SUITE 10.0 TANDBERG MANAGEMENT SUITE 10.0 Installation Manual Getting Started D12786 Rev.16 This document is not to be reproduced in whole or in part without permission in writing from: Contents INTRODUCTION 3 REQUIREMENTS

More information

BASLER ACE QUICK INSTALLATION GUIDE

BASLER ACE QUICK INSTALLATION GUIDE BASLER ACE QUICK INSTALLATION GUIDE Rev. 01 Quick installation Guide V1 1 Introduction The installation procedures in this guide assume that you want to get your camera operational and begin capturing

More information

USB FLASH DRIVE. User s Manual 1. INTRODUCTION...1 1.1. FEATURES...1 1.2. SPECIFICATIONS...2 1.3. PACKAGE CONTENTS...2 1.4. SYSTEM REQUIREMENTS...

USB FLASH DRIVE. User s Manual 1. INTRODUCTION...1 1.1. FEATURES...1 1.2. SPECIFICATIONS...2 1.3. PACKAGE CONTENTS...2 1.4. SYSTEM REQUIREMENTS... Table of Contents 1. INTRODUCTION...1 1.1. FEATURES...1 1.2. SPECIFICATIONS...2 1.3. PACKAGE CONTENTS...2 1.4. SYSTEM REQUIREMENTS...2 2. INSTALLATION PROCEDURE...3 2.1. INSTALL USB FLASH DRIVE ON WINDOWS

More information

Ultra Thin Client TC-401 TC-402. Users s Guide

Ultra Thin Client TC-401 TC-402. Users s Guide Ultra Thin Client TC-401 TC-402 Users s Guide CONTENT 1. OVERVIEW... 3 1.1 HARDWARE SPECIFICATION... 3 1.2 SOFTWARE OVERVIEW... 4 1.3 HARDWARE OVERVIEW...5 1.4 NETWORK CONNECTION... 7 2. INSTALLING THE

More information

PEAK DVB-T DIGITAL PCI CARD Installation Manual

PEAK DVB-T DIGITAL PCI CARD Installation Manual PEAK DVB-T DIGITAL PCI CARD Installation Manual Contents V1.0 Chapter 1 : PEAK DVB-T DIGITAL PCI CARD Hardware Installation...2 1.1 Package Contents...2 1.2 System Requirements...2 1.3 Hardware Installation...2

More information

Installing, upgrading and troubleshooting your CLIO system under the Windows environment.

Installing, upgrading and troubleshooting your CLIO system under the Windows environment. Installing, upgrading and troubleshooting your CLIO system under the Windows environment. Audiomatica Srl Rev. 1.1. June 2001. Contents 1 What does this document cover?... 1 2 Windows compatibility...

More information

DELLORTO. Instructions Manual. Deuss Service Tool For ECS System ECU. Dell Orto Deuss Service Tool instruction manual Page 1 of 11.

DELLORTO. Instructions Manual. Deuss Service Tool For ECS System ECU. Dell Orto Deuss Service Tool instruction manual Page 1 of 11. DELLORTO Deuss Service Tool For ECS System ECU Instructions Manual Dell Orto Deuss Service Tool instruction manual Page 1 of 11 Revision History Level Date Author Change Description and section(s) affected

More information

testo EasyClimate Software Instruction manual

testo EasyClimate Software Instruction manual testo EasyClimate Software Instruction manual 2 1 Contents 1 Contents 1 Contents... 3 1.1. About this document... 5 2 Specifications... 5 2.1. Use... 5 2.2. System requirements... 6 3 First steps... 6

More information

Guide to Installing BBL Crystal MIND on Windows 7

Guide to Installing BBL Crystal MIND on Windows 7 Guide to Installing BBL Crystal MIND on Windows 7 Introduction The BBL Crystal MIND software can not be directly installed on the Microsoft Windows 7 platform, however it can be installed and run via XP

More information

Table of Contents. 1. Overview... 3. 1.1 Materials Required. 3 1.2 System Requirements. 3 1.3 User Mode 3. 2. Installation Instructions..

Table of Contents. 1. Overview... 3. 1.1 Materials Required. 3 1.2 System Requirements. 3 1.3 User Mode 3. 2. Installation Instructions.. Table of Contents 1. Overview..... 3 1.1 Materials Required. 3 1.2 System Requirements. 3 1.3 User Mode 3 2. Installation Instructions.. 4 2.1 Installing the On Call Diabetes Management Software. 4 2.2

More information

Back Office Recorder 4iP Installation Guide Intelligent Recording Limited

Back Office Recorder 4iP Installation Guide Intelligent Recording Limited Back Office Recorder 4iP Installation Guide Intelligent Recording Limited Downloads Available at www.usbcallrecord.com UK Office +44 (0) 1909 512148 US Office +1 949.587.1226 Copyright Intelligent Recording

More information

Animated Lighting Software Overview

Animated Lighting Software Overview Animated Lighting Software Revision 1.0 August 29, 2003 Table of Contents SOFTWARE OVERVIEW 1) Dasher Pro and Animation Director overviews 2) Installing the software 3) Help 4) Configuring the software

More information

oxigen system Slot.it oxigen timing RMS installation Dongle driver installation 1/ 11 Race Management Software

oxigen system Slot.it oxigen timing RMS installation Dongle driver installation 1/ 11 Race Management Software 1/ 11 Slot.it oxigen timing RMS installation To install the Slot.it oxigen timing-rms software, follow these steps: 1. download the O2_chrono_installer.zip file from Slot.it ftp site; 2. unzip the downloaded

More information

DASHBOARD SOFTWARE Ver 1.2.2

DASHBOARD SOFTWARE Ver 1.2.2 POCKET USER GUIDE DASHBOARD SOFTWARE Ver 1.2.2 1 Thank you for purchasing the ASK Controls GPRS Quad Switch, it represents the very latest in remote switching technology to allow control of multiple circuits,

More information

Installing S500 Power Monitor Software and LabVIEW Run-time Engine

Installing S500 Power Monitor Software and LabVIEW Run-time Engine EigenLight S500 Power Monitor Software Manual Software Installation... 1 Installing S500 Power Monitor Software and LabVIEW Run-time Engine... 1 Install Drivers for Windows XP... 4 Install VISA run-time...

More information

QUICK TUNE EFI INSTRUCTION MANUAL

QUICK TUNE EFI INSTRUCTION MANUAL QUICK TUNE EFI INSTRUCTION MANUAL Step 1: Loading the CB quick Tune Software to your PC A) Take the CB Quick Tune installation CD and load it into your PC. A window will pop up asking to have all programs

More information

Running the R4 Software on a USB Port

Running the R4 Software on a USB Port Tech Note Running the R4 Software on a USB Port Like a lot of other engine management software programs that have been around for a while, the R4 program is designed to communicate through a 9-pin serial

More information

LG External HDD Hard Disk Drive XG1

LG External HDD Hard Disk Drive XG1 LG External HDD Hard Disk Drive XG1 - Thank you for purchasing this product. - This user manual contains instructions on how to use the product properly. - Please read this manual carefully. - Be sure

More information

SiS964 RAID. User s Manual. Edition. Trademarks V1.0 P/N: 91-187-U49-M2-0E

SiS964 RAID. User s Manual. Edition. Trademarks V1.0 P/N: 91-187-U49-M2-0E SiS964 RAID User s Manual Edition V1.0 P/N: 91-187-U49-M2-0E Trademarks All brand or product names mentioned are trademarks or registered trademarks of their respective holders. CONTENTS Introduction...

More information

LOREX CLIENT Remote Software 4.0

LOREX CLIENT Remote Software 4.0 LOREX CLIENT Remote Software 4.0 Instruction Manual English Version 2.0 MODEL: L20WD800 Series www.lorexcctv.com Copyright 2008 LOREX Technology Inc. Table of Contents Table of Contents Software Installation...

More information

User s Guide for version 5 Page

User s Guide for version 5 Page Network Management Interface Catalog VPi 32.15E For use with these ATS products: 7000 & 4000 Series (Group 5 Controller) Series 300 (Group 1 Controller), and 940, 962, 436, 434, 447, 448 (Group 6A/7A Control

More information

Global Water Instrumentation, Inc.

Global Water Instrumentation, Inc. Global Water Instrumentation, Inc. 151 Graham Road P.O. Box 9010 College Station, TX 77842-9010 Telephone : 800-876-1172 International : (979) 690-5560, Fax : (979) 690-0440 e-mail : globalw@globalw.com

More information

IXP120 Alarm Monitor Utility

IXP120 Alarm Monitor Utility IXP120 Alarm Monitor Utility SOFTWARE MANUAL Scope of Document This document provides a brief overview of the Alarm Monitor Utility and its interaction with the IXP120 Software. Document Conventions We

More information

RAID installation guide for ITE8212F

RAID installation guide for ITE8212F RAID installation guide for ITE8212F Contents Contents 2 1 Introduction 3 1.1 About this Guide 3 1.2 The Basics 3 1.2.1 What is RAID? 3 1.2.2 Advantages of RAID 3 1.2.3 Disadvantages of RAID 3 1.3 Different

More information

APPLICATION NOTE. The DMP Software Family DMP COMPUTER SOFTWARE PROGRAMS

APPLICATION NOTE. The DMP Software Family DMP COMPUTER SOFTWARE PROGRAMS APPLICATION NOTE Contents The DMP Software Family... 1 Stand-Alone Link Software... 1 Add-on Modules for Link Software... 1 System Link End-User Panel Management Software... 2 Simple Registration and Activation...

More information

DaliControl Service and Comisioning Wizard Version 1.1. Softwaretool. User Manual. Revision: 2006-06-22

DaliControl Service and Comisioning Wizard Version 1.1. Softwaretool. User Manual. Revision: 2006-06-22 DaliControl Service and Comisioning Wizard Version 1.1 Softwaretool User Manual Copyright and Notes This software and documentation are property of IPAS GmbH, Germany. Windows 2000, Windows XP, Windows

More information

1. Introduction... 3 Introduction...2. 4. Deal command... 13

1. Introduction... 3 Introduction...2. 4. Deal command... 13 Dealer4 PC Software User Manual Service Software Manual ver:ver: 1.11.2 1. Introduction... 3 Introduction...2 2.1 Main Menu... 4 2.1. Main Menu window...4 Summary of additional functions...3 2.2. Board

More information

Model 288B Charge Plate Graphing Software Operators Guide

Model 288B Charge Plate Graphing Software Operators Guide Monroe Electronics, Inc. Model 288B Charge Plate Graphing Software Operators Guide P/N 0340175 288BGraph (80207) Software V2.01 100 Housel Ave PO Box 535 Lyndonville NY 14098 1-800-821-6001 585-765-2254

More information

Specific Information for installation and use of the database Report Tool used with FTSW100 software.

Specific Information for installation and use of the database Report Tool used with FTSW100 software. Database Report Tool This manual contains: Specific Information for installation and use of the database Report Tool used with FTSW100 software. Database Report Tool for use with FTSW100 versions 2.01

More information

Analyzer 2.0. Installation Guide. Contents

Analyzer 2.0. Installation Guide. Contents Analyzer 2.0 Analyzer 2.0 is a comprehensive suite of tools designed to help you analyze complex aqueous and multisolvent electrolyte solution chemistry, thermophysical properties, phase behavior and corrosion

More information

How To Use An Ams 5812 Pressure Sensor With A Usb Starter Kit

How To Use An Ams 5812 Pressure Sensor With A Usb Starter Kit User Guide USB Starter Kit AMS 5812 Phone:+49 (0)6131/91 0730-0 Fax: +49 (0)6131/91 073-30 Internet: E Mail: info@analogmicro.de Analog Microelectronics GmbH An der Fahrt 13, D 55124 Mainz May 2012 - Rev.

More information

CurveMaker v2.1 DYNAFS programmable ignition software

CurveMaker v2.1 DYNAFS programmable ignition software CurveMaker v2.1 DYNAFS programmable ignition software Dynatek 164 S Valencia St. Glendora CA 91741 phone (626)963-1669 fax (626)963-7399 Contents 1) Installation...1 2) Overview...1 3) Programming a Curve...4

More information

How to read this guide

How to read this guide How to read this guide The following shows the symbols used in this Quick start guide with descriptions and examples. Symbol Description Example P oint Reference Caution [ ] This symbol explains information

More information

How To Download From A Tachograph With A Tachoreader Combo (Tachograph)

How To Download From A Tachograph With A Tachoreader Combo (Tachograph) External Devices Handling Data transfer from digital tachograph PC NET SERVICE Stocerz Sp. J. Other devices - Tutorial - Pomoc All rights reserved. No parts of this work may be reproduced in any form or

More information

Installation Instructions

Installation Instructions Installation Instructions Windows USB driver for Installation If a Diagnostic Interface with USB is connected to a PC with a Windows operating system 98, ME, XP or Vista for the first time, it is necessary

More information

RAINCONTROL LCD Special

RAINCONTROL LCD Special RAINCONTROL LCD Special edition 1.1 01/2007 - code 5880 1/16 RAINCONTROL LCD SPECIAL... 3 RAINCONTROL SPECIAL LCD PANEL PRESENTATION... 4 AUTO... 5 LOW AND HIGH THRESHOLD SETTING... 6 LOW THRESHOLD...

More information

JEROME COMMUNICATIONS SOFTWARE (JCS) INSTALLATION and OPERATION MANUAL V1.02 for Windows XP

JEROME COMMUNICATIONS SOFTWARE (JCS) INSTALLATION and OPERATION MANUAL V1.02 for Windows XP AZI P/N 700-0042-B Last update May 2009 USER MANUAL JEROME COMMUNICATIONS SOFTWARE (JCS) INSTALLATION and OPERATION MANUAL V1.02 for Windows XP May 2009 ARIZONA INSTRUMENT LLC 3375 N Delaware Street Chandler,

More information

How To Run A Factory I/O On A Microsoft Gpu 2.5 (Sdk) On A Computer Or Microsoft Powerbook 2.3 (Powerpoint) On An Android Computer Or Macbook 2 (Powerstation) On

How To Run A Factory I/O On A Microsoft Gpu 2.5 (Sdk) On A Computer Or Microsoft Powerbook 2.3 (Powerpoint) On An Android Computer Or Macbook 2 (Powerstation) On User Guide November 19, 2014 Contents 3 Welcome 3 What Is FACTORY I/O 3 How Does It Work 4 I/O Drivers: Connecting To External Technologies 5 System Requirements 6 Run Mode And Edit Mode 7 Controls 8 Cameras

More information

PIGCHAMP MOBILE. PigCHAMP Knowledge Software. Installation Guide for Mobile Units

PIGCHAMP MOBILE. PigCHAMP Knowledge Software. Installation Guide for Mobile Units PIGCHAMP MOBILE PigCHAMP Knowledge Software Installation Guide for Mobile Units Table of Contents: Important Note:... 4 Chapter 1: PC Setup... 5 A. Install PigCHAMP Mobile Manager on Windows XP...5 B.

More information

GUARD1 PLUS SE Administrator's Manual

GUARD1 PLUS SE Administrator's Manual GUARD1 PLUS SE Administrator's Manual Version 4.4 30700 Bainbridge Road Solon, Ohio 44139 Phone 216-595-0890 Fax 216-595-0991 info@guard1.com www.guard1.com i 2010 TimeKeeping Systems, Inc. GUARD1 PLUS

More information

Installing Remote Desktop Connection

Installing Remote Desktop Connection SETTING UP YOUR REMOTE DESKTOP This section will assist you in setting you Remote Desktop Connection. This will allow you to create an icon for easy access to your virtual desktop. DISCLAIMER: All images

More information

HP-1000 Powerline Ethernet Adapter

HP-1000 Powerline Ethernet Adapter HP-1000 Powerline Ethernet Adapter User s manual BEFORE INSTALLATION Plan ahead the installation of your powerline network. Note: You will need at least two powerline adapters to create a powerline network.

More information

Module 6 Engine Control Module (ECM)

Module 6 Engine Control Module (ECM) Module 6 Engine Control Module (ECM) Author: Grant Swaim E-mail: sureseal@nr.infi.net URL: www.tech2tech.net Phone: (336) 632-9882 Fax: (336) 632-9688 Postal Address: Tech-2-Tech Website PO Box 18443 Greensboro,

More information

Cart Interface Installation & Control Board Manual for M38 XP and RX Carts and Legacy M39 Carts

Cart Interface Installation & Control Board Manual for M38 XP and RX Carts and Legacy M39 Carts Rubbermaid Medical Solutions Cart Interface Installation & Control Board Manual for M38 XP and RX Carts and Legacy M39 Carts REVISED FEBRUARY 25, 2010 Filename: Cart Interface Installation & Control Board

More information

HP-1000 Powerline USB Adapter

HP-1000 Powerline USB Adapter HP-1000 Powerline USB Adapter User s manual BEFORE INSTALLATION Plan ahead the installation of your powerline network. Note: You will need at least two powerline adapters to create a powerline network.

More information

S&G Audit Lock. Audit Trail Software Manual

S&G Audit Lock. Audit Trail Software Manual S&G Audit Lock Audit Trail Software Manual The Sargent & Greenleaf Audit Lock is designed to provide a high level of security. One of the ways they accomplish this is by offering detailed audit trails.

More information

User Manual Software for DSL Digital Speed Switch

User Manual Software for DSL Digital Speed Switch User Manual Software for DSL Digital Speed Switch Software version from 1.0.1 Baumer Hübner GmbH Max-Dohrn-Str. 2+4 D-10589 Berlin Phone +49 (0)30 690 03-0 Fax +49 (0)30 690 03-104 info@baumerhuebner.com

More information

DUKANE Intelligent Assembly Solutions

DUKANE Intelligent Assembly Solutions PC Configuration Requirements: Configuration Requirements for ipc Operation The hardware and operating system of the PC must comply with a list of minimum requirements for proper operation with the ipc

More information

Current Monitoring Kit

Current Monitoring Kit Current Monitoring Kit QUICK START GUIDE DO090-6 CONTENTS Issues: 1) 2.10.02 WP A4 format 2) 2.10.02 Added safety warning 3) 17.3.06 Word A5 format. S1: Removed relay modules. S2: Added MI010. S4.1: added

More information

Compressor Supreme Force Feedback User Manual

Compressor Supreme Force Feedback User Manual 1. Setting up Compressor Supreme 1. Connect the gear shifter to the back panel of the steering wheel column. 2. Connect the foot pedals to the back panel of the steering wheel column. 3. Connect the A.C.

More information

1. Introduction... 3. 2.Fixture exterior view... 3. 3. Connecting the Robe Universal Interface... 4. 3.1 Software update of the fixture...

1. Introduction... 3. 2.Fixture exterior view... 3. 3. Connecting the Robe Universal Interface... 4. 3.1 Software update of the fixture... 1 Table of contests 1. Introduction... 3 2.Fixture exterior view... 3 3. Connecting the Robe Universal Interface... 4 3.1 Software update of the fixture... 4 3.2 Connecting a DMX console to the Media Fusion...

More information

Call Recorder Oygo Manual. Version 1.001.11

Call Recorder Oygo Manual. Version 1.001.11 Call Recorder Oygo Manual Version 1.001.11 Contents 1 Introduction...4 2 Getting started...5 2.1 Hardware installation...5 2.2 Software installation...6 2.2.1 Software configuration... 7 3 Options menu...8

More information