PX Serial. User Guide

Size: px
Start display at page:

Download "PX Serial. User Guide"

Transcription

1 PX Serial User Guide International HQ Jerusalem, Israel Tel: minicom@minicom.com c om North America Technical support - support@minicom.com Linden, NJ, USA Tel: info.usa@minicom.com SC_5UM70171 V1.2 10/09

2 PX SERIAL Table of Contents 1. Welcome Introduction Integration into KVM.net The PX Serial components PX Serial ports PX Serial LEDs Mounting the PX Serial Connecting the PX Serial Connecting the Power supply Terminal Block (PWR1) Power Jack (PWR2) Connecting to the network switch Connecting to the Serial device Configuring the dipswitches Restoring the default settings Configuring the PX Serial unit Basic settings Network Setting Change password Port Configuration Serial Setting Port Profile Service Mode Management IP filtering and SNMP Trap Notification Event Notification Saving configuration changes...17 Maintenance Configuring the PX via SSH client Operating the device SNMP MIB II support Integrating the PX Serial into the KVM.net system Installing the script on the KVM.net manager Configuring the KVM.net system Win XP with IE Microsoft Vista IE RS232 pin assignment Technical specifications User guide feedback WEEE compliance

3 1. Welcome USER GUIDE Thank you for buying the PX Serial system. This system is produced by Minicom Advanced Systems Limited. This document provides installation and operation instructions for Minicom s PX Serial. It is intended for system administrators and network managers, and assumes that readers have a general understanding of networks, hardware and software. Technical precautions This equipment generates radio frequency energy and if not installed in accordance with the manufacturer s instructions, may cause radio frequency interference. This equipment complies with Part 15, Subpart J of the FCC rules for a Class A computing device. This equipment also complies with the Class A limits for radio noise emission from digital apparatus set out in the Radio Interference Regulation of the Canadian Department of Communications. These above rules are designed to provide reasonable protection against such interference when operating the equipment in a commercial environment. If operation of this equipment in a residential area causes radio frequency interference, the user, and not Minicom Advanced Systems Limited, will be responsible. Changes or modifications made to this equipment not expressly approved by Minicom Advanced Systems Limited could void the user s authority to operate the equipment. Minicom Advanced Systems Limited assumes no responsibility for any errors that appear in this document. Information in this document is subject to change without notice. No part of this document may be reproduced or transmitted in any form or by any means, electronic or mechanical, for any purpose, without the express written permission of Minicom Advanced Systems Limited. Trademarks All trademarks and registered trademarks are the property of their respective owners Copyright Minicom Advanced Systems. All rights reserved. 2

4 PX SERIAL 2. Introduction PX Serial is a one-port RS232/422/485 to Redundant Ethernet device server. PX Serial can be configured by a web browser in https, or SSH console. Additional management features include SNMP support and alerts. 2.1 Integration into KVM.net PX Serial can be integrated in the KVM.net system and managed by the KVM.net. KVM.net is a robust central management appliance that provides reliable and secure management of KVM IP devices. KVM.net integrates with KVM IP devices to facilitate an intuitively manageable, centralized out-of-band access portal - designed to maintain all IT assets. LDAP based KVM.net centralizes all user account information relevant for IP device administration without interfering in the stand-alone survivability of each device. Designed to work across LAN or WAN, KVM.net, monitors and auto configures KVM IP devices whether residing on t he local enterprise network or in remote branches. KVM.net delivers the most advanced solution for enterprise IT management and remote control. It supports hundreds of servers in an environment that is completely configurable by the network administrator. Section 16 on page 23 explains how to integrate the PX Serial in the KVM.net system. 3. The PX Serial components The package includes: 1 PX Serial unit 1 Power adapter ( VAC) Mounting kit foot pads Minicom CD 3

5 4. PX Serial ports USER GUIDE Hardware reset button Long distance RS422 / Ohm termination dipswitches RS232/422/482 port, DB9M 15KV ESD for all signals Speed:110 bps to 460.8kbps Figure 1 PX Serial ports side VDC Terminal Block 9-30 VDC Power Jack Redundant Dual 10/100M Ethernet Auto MDI/MDIX Auto- Recovery<200ms Built-in 1.5KV magnetic isolation Figure 2 PX Serial ports side 2 4

6 5. PX Serial LEDs PX SERIAL LED Color Indication PWR 1 PWR 2 Eth 1 Eth 2 Serial Red Green Off Red Green Off Orange Green Off Orange Green Off Orange Green Off On: Power 1 is on and booting up. Blinking: Indicates an IP conflict, or DHCP or BOOTP server did not respond properly. On: Power is on and functioning normally. Blinking: Located by Administrator s Location function. Power is off, or power error condition exists. On: Power 2 is on and booting up. Blinking: Indicates an IP conflict, or DHCP or BOOTP server did not respond properly On: Power 2 is on and functioning normally. Blinking: Located by Administrator s Location function. Power is off, or power error condition exists. Blinking: 10 Mbps Ethernet connection. Blinking: 100 Mbps Ethernet connection. Ethernet cable is disconnected, or has a short. Blinking: 10 Mbps Ethernet connection. Blinking: 100 Mbps Ethernet connection. Ethernet cable is disconnected, or has a short. Serial port is receiving data. Serial port is transmitting data. 6. Mounting the PX Serial Wall mounting No data is being transmitted or received through the serial port. Use the supplied screws to mount the ears on a wall. Din-rail mounting Screw the din-rail Mounting clips to the PX ears and mount on a din-rail. 7. Connecting the PX Serial Connect the PX Serial to the power supply, the Network switch and Serial device as explained below. 7.1 Connecting the Power supply You can connect the PX Serial to the Power supply using the Terminal Block (PWR1) and/or the Power Jack (PWR2). If both power inputs are connected, the PX Serial is powered from the highest connected voltage. The PX Serial will only send a loss of power alarm when power fails at both PWR1 and PWR2. 5

7 7.1.1 Terminal Block (PWR1) USER GUIDE 1. Insert the positive and negative wires of your DC supply into the V+ and V- contacts of the terminal block connector see below. (GND / V- / V+) 2. Tighten the terminal screws to prevent the DC wires from coming loose see below. Once connected to the power supply, Power 1 LED turns red to show unit booting up. When the unit is ready and if the IP setting is running correctly, the LED turns green Power Jack (PWR2) Connect the supplied 12VDC power adapter, or 24VDC power input to the power jack. Power 2 LED turns red to show unit booting up. When the unit is ready and if the IP setting is running correctly the LED turns green. 7.2 Connecting to the network switch Connect the PX Serial to the network switch via the LAN 1 or LAN 2 port using a standard 10/100M Ethernet cable. The Ethernet interface supports auto MDI/MDIX. The relevant LAN 1 or LAN 2 LED turns orange for 10M Ethernet or green for 100M Ethernet. Both Ethernet ports 1 and 2 can be connected to different switches. If both ports are connected when the device starts up then Ethernet port 1 is the master and Ethernet port 2 is the backup. But if when the device starts up only Ethernet port 2 is connected, then Ethernet port 2 remains the master port. 6

8 PX SERIAL 7.3 Connecting to the Serial device Connect the Serial device to the DB9M port. The DB9M pin-out appears below. Standard DB9M connector Pin # RS232 RS422 RS485 (4 wire) RS485(2 wire) 1 DCD RXD- RXD- 2 RXD RXD+ RXD+ 3 TXD TXD+ TXD+ DATA+ 4 DTR TXD- TXD- DATA- 5 GND GND GND GND 6 DSR 7 RTS 8 CTS 9 RI RS232 mode act as DTE 7.4 Configuring the dipswitches The Long-Range Termination dipswitches can configure 120 Ohm termination for RS422 / 4-wire RS485 / 2-wire RS485. Set the dipswitches according to the following table. Dipswitch 1 Dipswitch 2 Configuration ON ON 120 Ohm terminator for long distance 4-wire RS485 / RS422 ON OFF Don t use this setting - it will cause errors! OFF ON 120 Ohm termination for long distance 2-wire RS485 OFF OFF (Default) No termination for RS232/422/485 (short distance) 8. Restoring the default settings To restore the default settings of the PX Serial press the Reset button see Figure 1 - for 10 seconds. Release after the Power LED blinks red. All values are restored to their defaults including the IP address ( ), and password protection (if activated) is removed. When the Power LED turns green, the device is ready to function. 7

9 USER GUIDE 9. Configuring the PX Serial unit The PX Serial unit can be managed by a Web interface, providing secure SSL communication over the internet. The PX Serial comes with the default IP address this appears on the underside of the PX unit. To display the Web interface: 1. Open your Web browser. 2. Type in the IP address of the PX Serial and press Enter. Note! The IP address must begin with and not The web interface appears, see Figure 3. Bookmark it for easy reference. Figure 3 Overview page The Overview page gives details of the current IP address, MAC address and firmware version. The MAC address is also shown on the underside of the unit. From the menu click Server Configuration to display a sub-menu. 8

10 9.1 Basic settings PX SERIAL Click Basic Setting, the following appears. On this page configure: Figure 4 Basic Setting The server name connected to the PX Time Server settings You can disable the Telnet console e.g. to block access to the device for maintenance purposes. 9

11 USER GUIDE 9.2 Network Setting Consult your Network Administrator for the network settings. Click Network Setting, the following appears. On this page you configure for the PX: Figure 5 Network Setting IP Configuration DHCP or static IP address Netmask Gateway DNS servers For dynamic IP address reporting at defined time intervals, fill in the Auto IP report fields. 9.3 Change password By default access to the web configuration interface is not password protected. To add password protection: 1. Click Change password, the following appears. 10

12 PX SERIAL Figure 6 Change password 2. Type a password in the fields. Do not use spaces between the characters. 10. Port Configuration Port Configuration covers Serial Parameter settings, such as baud rate, data bits, stop bits, parity, and flow control. From the menu click Port Configuration to display a sub-menu Serial Setting Click Serial Setting, the following appears. Figure 7 Serial Setting Port Alias: Give the port an identifying name to be identified by the connected device. 11

13 USER GUIDE Select the Interface: RS232 / RS422 / RS485 (2-wires) / RS485(4-wires) Select the settings for Baud rate, Data Bits, Stop Bits, Parity and Flow Control. Force TX interval time is to specify a timeout when no data has been transmitted. When the timeout is reached or TX buffer is full (4K Bytes), the queued data will be sent. Zero (factory default) means disabled. Performance options: Select Throughput for the fastest possible transmission speed. Select Latency for the shortest response time Port Profile Click Port Profile, the following appears. Figure 8 Port Profile For advanced data packing options, you can specify delimiters for Serial to Ethernet and / or Ethernet to Serial communications. You can define up to a maximum of 4 delimiters (00~FF, HEX) for each way. The data will be held until the delimiters are received or the optional Flush Ethernet to Serial data buffer times out. Zero means disable (factory default). 12

14 10.3 Service Mode PX SERIAL Click Service Mode, the following appears. Figure 9 Service Mode In TCP Server mode, you must define the available port number, idle timeout, alive check, and maximum number (between 1 and 5) of simultaneous connections allowed to the web configuration pages. Idle Timeout: When the serial port stops data transmission for a defined period of time (Idle Timeout), the connection will close and the port is free to try connecting with other hosts. Zero disables this setting (default). Alive Check: The PX device sends a TCP package at each defined time interval (Alive Check) to the remote host to test the TCP connection. If the TCP connection is dead, the connection closes and the port is free for other hosts. Zero, disables this setting (default). 13

15 11. Management USER GUIDE From the menu click Management to display a sub-menu IP filtering Click IP filtering, the following appears. Figure 10 Access IP Setting The Access IP Setting table specifies the IP address and subnet that can access the device. The access is based on the IP and Netmask combination. E.g. type the IP address and Netmask and select the Activate the IP checkbox to give this host access to the device. Note! For access from all hosts, do NOT enable this function. 14

16 PX SERIAL and SNMP Trap Notification Click and SNMP Trap, the following appears. Figure 11 and SNMP Trap Server configuration includes the mail server s IP address or domain. If authentication is required, specify the username and password. There are 4 addresses you can specify to receive the notification. SNMP Trap configuration includes up to 4 Trap Servers. You need to at least fill in one Trap Server s IP or domain. The Community is also required information. Do not use the ; in this column. Location and Contact is optional information. For Syslog Server configuration type in the Syslog Server IP address and port number. 15

17 11.3 Event Notification USER GUIDE Click Event Notification, the following appears. Figure 12 Device Notification: Specify the events that should be notified to the administrator. The events can be notified by means of , SNMP traps, or system logs. Port Notification: DCD changed: When DCD (Data Carrier Detect) signal changes, indicating the modem connection status has changed, the event will be triggered. DSR changed: When DSR (Data Set Ready) signal changes, indicating that the data communication equipment is powered off, the event will be triggered. RI changed: When RI (Ring Indicator) signal changes, indicating the incoming of a call, the event will be triggered. CTS changed: When CTS (Clear To Send) signal changes, indicating that the transmission between computer and DCE can proceed. Port connected: When the device accepts an incoming TCP connection, this event will be a trigger. Port disconnected: When the device loses the TCP link, this event will be trigger. Select the desired events and the type of notification - , SNMP Trap or system. 16

18 PX SERIAL 12. Saving configuration changes To save any configuration changes, click Submit Maintenance Click Maintenance, the following appears. Figure 13 Maintenance From the Maintenance page you can do the following: Load Factory Default: Load default configuration except Network Settings. Import Configuration: Retrieve saved configuration files to apply to the device. Click Browse to choose the configuration file then click the Import command. Export Configuration: Save the current configuration into a file and save the file in current host. Upgrade Firmware: Upgrade to new firmware. Click Browse to select the firmware then click Upgrade command. 13. Configuring the PX via SSH client Configuration of the PX Serial can also be done via an SSH client. There are many SSH clients, for example, PuTTY is a free and popular Telnet/SSH client. PuTTY is used below to illustrate how to login to the PX by SSH. Download PuTTY from: Open PuTTY. The PuTTY Configuration window appears, see the figure below. 17

19 USER GUIDE Figure 14 PuTTY Configuration Type the Host Name or IP Address of your PX (default: ). The Port number is the default For Connection type, choose SSH. Click Open to start the SSH session console. The SSH console appears, see figure below. Figure 15 SSH console Type the username admin and password admin. The following appears. 18

20 PX SERIAL Figure 16 PX Serial Commander Configure the device and port by pressing the desired function number or letter. Press q to exit the function. Note! Press a to apply and save changes. The configuration settings are the same as set out above for configuration via the web. 14. Operating the device Once configured, use a Telnet console or similar application - PuTTY, Tera Term, Secure CRT - to connect to the PX Serial and operate the Serial device. The IP address and TCP server port number is as defined in the Server Mode, see Figure 9 on page 13 above. Connection from Windows Telnet: Telnet [IP address] [Port No.]. Figure 17 Telnet 19

21 USER GUIDE Connection from PuTTY: [IP address] [Port No.]. Figure 18 PuTTY Connection from Tera Term Web: [IP address] [Port No.]. Figure 19 Tera Term Web Once connected operate the Serial device according to the device s instructions. 20

22 15. SNMP MIB II support PX SERIAL PX has a built-in SNMP agent that supports SNMP traps, RFC 1317 RS232 MIB and RFC1213 MIB-II. The following tables list SNMP variables implemented in the PX. RFC1213 MIB-II supported SNMP variables System MIB sysdescr sysobjectid sysuptime syscontact sysname syslocation sysorlastchange sysorid sysordescr sysoruptime Interface MIB ifnumber ifindex ifdescr iftype ifmtu fspeed ifphysaddress ifadminstatus ifoperstatus ifinoctets ifinucastpkts ifindiscards ifinerrors ifoutoctets ifoutucastpkts ifoutdiscards ifouterrors ifoutqlen ifspecific Address MIB atifindex atphysaddress atnetaddress IP MIB ipforwarding ipdefaultttl ipinreceives ipinhdrerrors ipinaddrerrors ipforwdatagrams ipinunknownprotos ipindiscards ipindelivers ipoutrequests ipoutdiscards ipoutnoroutes ipreasmtimeout ipreasmreqds ipreasmoks ipreasmfails ipfragoks ipfragfails ipfragcreates ipadentaddr ipadentifindex ipadentnetmask ipadentbcastaddr iproutedest iprouteifindex iproutemetric1 iproutenexthop iproutetype iprouteproto iproutemask iprouteinfo ipnettomediaifindex ipnettomediaphysaddress ipnettomedianetaddress ipnettomediatype iproutingdiscards ICMP MIB icmpinmsgs icmpinerrors icmpindestunreachs icmpintimeexcds icmpinparmprobs icmpinsrcquenchs icmpinredirects icmpinechos icmpinechoreps icmpintimestamps icmpintimestampreps icmpinaddrmasks icmpinaddrmaskreps icmpoutmsgs icmpouterrors icmpoutdestunreachs icmpouttimeexcds icmpoutparmprobs icmpoutsrcquenchs icmpoutredirects icmpoutechos icmpoutechoreps icmpouttimestamps icmpouttimestampreps icmpoutaddrmasks icmpoutaddrmaskreps 21

23 USER GUIDE TCP MIB tcprtoalgorithm tcprtomin tcprtomax tcpmaxconn tcpactiveopens tcppassiveopens tcpattemptfails tcpestabresets tcpcurrestab tcpinsegs tcpoutsegs tcpretranssegs tcpconnstate tcpconnlocaladdress tcpconnlocalport tcpconnremaddress tcpconnremport tcpinerrs tcpoutrsts. UDP MIB udpindatagrams udpnoports udpinerrors udpoutdatagrams udplocaladdress udplocalport SNMP MIB snmpinpkts snmpoutpkts snmpinbadversions snmpinbadcommunitynames snmpinbadcommunityuses snmpinasnparseerrs snmpintoobigs snmpinnosuchnames snmpinbadvalues snmpinreadonlys snmpingenerrs snmpintotalreqvars snmpintotalsetvars snmpingetrequests snmpingetnexts snmpinsetrequests snmpingetresponses snmpintraps snmpouttoobigs snmpoutnosuchnames snmpoutbadvalues snmpoutgenerrs snmpoutgetrequests snmpoutgetnexts snmpoutsetrequests snmpoutgetresponses snmpouttraps snmpenableauthentraps snmpsilentdrops snmpproxydrops RFC1317 RS232 supported SNMP variables RS232 MIB rs232number rs232portindex rs232porttype rs232portinsignumber rs232portoutsignumber rs232portinspeed rs232portoutspeed rs232portinflowtype rs232portoutflowtype rs232asyncportindex rs232asyncportbits rs232asyncportstopbits rs232asyncportparity rs232asyncportautobaud rs232asyncportparityerrs rs232asyncportframingerrs rs232asyncportoverrunerrs rs232insigportindex rs232insigname rs232insigstate rs232insigchanges rs232outsigportindex rs232outsigname rs232outsigstate rs232outsigchanges 22

24 PX SERIAL 16. Integrating the PX Serial into the KVM.net system To integrate the PX Serial into the KVM.net system you need to install a script adding telnet support to the KVM.net system. You can then access a PX Serial from the Web Target page of the KVM.net system. The script can be found under the following link: Installing the script on the KVM.net manager 1. Download the script and unzip it to a temporary folder. 2. Using WinSCP connect to the KVM.net Manager and copy update.sh and web_target.html.patch to /misc, see below. Figure 20 Copying files from temporary folder 3. Using putty connect to the KVM.net Manager. 4. Type cd /misc t go to the misc directory. 5. Change the permissions of the update.sh file by running the command: chmod a+x upgrade.sh. 6. Update the KVM.net Manager by running the./update.sh command. There is no need to reboot the KVM.net Manager. 23

25 USER GUIDE 16.2 Configuring the KVM.net system 1. Login to the KVM.net as an administrator. 2. Select Targets Sets / Web Targets. The Web Targets page appears see below. Figure 21 Web Targets 3. From the toolbar, click. The following appears. Figure 22 Web Target Properties 4. Type the name and description of the device connected to the PX Serial 5. In the URL type using the following syntax: telnet://px Serial IP address:port number - e.g. telnet:// :4000 For the port number see the number of the Local TCP Port in the Port Profile of the PX Serial web interface as illustrated below. 6. Press Submit. Figure 23 Port Profile 24

26 Note! PX SERIAL The PX Serial has no authentication. This means that the serial device is open for anyone to connect to and operate it without any user name or password. All users, once connected to the KVM.net can connect the PX Serial regardless of his permissions Win XP with IE6 For Win XP with IE6, configuration is complete. Go to My Targets / Web Targets and press the target. The default configured terminal emulation program opens. E.g. HyperTerminal see below Microsoft Vista Figure 24 HyperTerminal Telnet is not installed on Vista. Install it and then follow the IE7 configuration below IE7 By default IE7 does not allow telnet addresses. To change this, execute the IE7_telnet.reg file included in the downloaded zip file. 25

27 17. RS232 pin assignment USER GUIDE Pin No. Name Notes/Description 1 DCD Data Carrier Detect 2 RD Receive Data (RxD, Rx) 3 TD Transmit Data (TxD, Tx) 4 DTR Data Terminal Ready 5 SGND Ground 6 DSR Data Set Ready 7 RTS Request To Send 8 CTS Clear To Send 9 RI Ring Indicator 26

28 PX SERIAL 18. Technical specifications Network Interface Ethernet Ethernet connector Protection Protocols 2 x 10/100BaseTX, Redundant Ethernet RJ45 Built-in 1.5 KV magnetic isolation ICMP, IP, TCP, UDP, DHCP, BootP, ARP / RARP, DNS, SNMP MIB II, HTTPS, SSH Serial Interface Interface RS232, RS422, 2/4-Wire RS485 Connectors male DB9 Data Rates 110 bps to Kbps Data Bits 5, 6, 7, 8 Parity odd, even, none Stop Bits 1, 1.5, 2 RS-232 TxD, RxD, RTS, CTS, DTR, DSR, GND, DCD RS-422 Tx+,Tx-, Rx+, Rx-,GND RS-485 (4-wire) Tx+,Tx-, Rx+, Rx-,GND RS-485 (2-wire) Data+, Data-,GND Flow Control XON/XOFF, RTS/CTS, DTR/DSR Serial Line Protection 15KV ESD Power Requirements Power Input Power Line protection PWR1: 12~48VDC in 2-pin Terminal block. PWR2: 9~30VDC in Power Jack with Power adapter 1 KV Burst (EFT), EN KV Surge, EN Dimensions Regulatory Approvals Operating Temperature Operating Humidity Storage Temperature 29.6 mm (H) x 96 mm(w) with ears x 99 mm (D) FCC Class A, CE Class A RoHS -10 to 70 C (14 to 158 F) 5% to 95% (Non-condensing) -20 to 85 C (-4 to 185 F) 27

29 19. User guide feedback USER GUIDE Your feedback is very important to help us improve our documentation. Please any comments to: Please include the following information: Guide name, part number and version number (as appears on the front cover). 20. WEEE compliance WEEE Information for Minicom Customers and Recyclers Under the Waste Electrical and Electronic Equipment (WEEE) Directive and implementing regulations, when customers buy new electrical and electronic equipment from Minicom they are entitled to: Send old equipment for recycling on a one-for-one, like-for-like basis (this varies depending on the country) Send the new equipment back for recycling when this ultimately becomes waste Instructions to both customers and recyclers/treatment facilities wishing to obtain disassembly information are provided in our website 28

30 PX SERIAL Germany Kiel Tel: info.germany@minicom.com England Tel: info.uk@minicom.com France Vincennes Regional Offices Tel: info.france@minicom.com Italy Rome Tel: info.italy@minicom.com 29

31 USER GUIDE 30

Simple Network Management Protocol Reference Guide

Simple Network Management Protocol Reference Guide D Simplify SANbox/SANbox2 Simple Network Management Protocol Reference Guide 59047-02 Rev. A Page i Simple Network Management Protocol Reference Guide Q Information furnished in this guide is believed

More information

Access Server. Administrator s Reference Guide

Access Server. Administrator s Reference Guide Access Server Administrator s Reference Guide 6DOHV2IIL H+1 (301) 975-1000 7H KQL DO6XSSRUW+1 (301) 975-1007 (PDLOsupport@patton.com :::www.patton.com 'R XPHQW1XPEHU107001U Rev. D 3DUW1XPEHUO7MDAS-ARG-D

More information

Simple Network Management Protocol Reference Guide

Simple Network Management Protocol Reference Guide D Simplify SANbox2 Simple Network Management Protocol Reference Guide 59047-00 Rev. A Page i Simple Network Management Protocol Reference Guide Q Information furnished in this guide is believed to be accurate

More information

HP STORAGEWORKS 8/8 SAN SWITCH

HP STORAGEWORKS 8/8 SAN SWITCH You can read the recommendations in the user guide, the technical guide or the installation guide for HP STORAGEWORKS 8/8 SAN SWITCH. You'll find the answers to all your questions on the HP STORAGEWORKS

More information

How To Run An Nport I5000A Device Server

How To Run An Nport I5000A Device Server NPort IA5000A Series 1, 2, and 4-port serial device servers for industrial automation Enhanced surge protection for serial, LAN, and power 2 KV isolation for serial signals Rugged screw-type terminal blocks

More information

User s Manual TCP/IP TO RS-232/422/485 CONVERTER. 1.1 Introduction. 1.2 Main features. Dynamic DNS

User s Manual TCP/IP TO RS-232/422/485 CONVERTER. 1.1 Introduction. 1.2 Main features. Dynamic DNS MODEL ATC-2000 TCP/IP TO RS-232/422/485 CONVERTER User s Manual 1.1 Introduction The ATC-2000 is a RS232/RS485 to TCP/IP converter integrated with a robust system and network management features designed

More information

NEC AMERICA, INC. Product Development Evaluation Division NEAX IPX /NEAX IPS. SNMP Implementation

NEC AMERICA, INC. Product Development Evaluation Division NEAX IPX /NEAX IPS. SNMP Implementation NEC AMERICA, INC. Product Development Evaluation Division NEAX IPX /NEAX IPS SNMP Implementation PRODUCT DEVELOPMENT EVALUATION DIVISION IPX/IPS SNMP Implementation NEC America, Inc. 6535 N. State Highway

More information

Serial over Ethernet Device Server. User s Manual

Serial over Ethernet Device Server. User s Manual Serial over Ethernet Device Server User s Manual Second Edition, November 2005 SUNIX Co., Ltd. Tel : +886-2-8913-1987 Fax: +886-2-8913-1986 Http://www.sunix.com.tw info@sunix.com.tw Serial over Ethernet

More information

LBNP16312. RS-232/485/422 serial device server. User manual

LBNP16312. RS-232/485/422 serial device server. User manual Tu Sitio de Automatización! LBNP16312 RS-232/485/422 serial device server User manual Summarize-----------------------------------------------------------------------------14-3 Package checklist---------------------------------------------------------------------14-3

More information

3.1 RS-232/422/485 Pinout:PORT1-4(RJ-45) RJ-45 RS-232 RS-422 RS-485 PIN1 TXD PIN2 RXD PIN3 GND PIN4 PIN5 T+ 485+ PIN6 T- 485- PIN7 R+ PIN8 R-

3.1 RS-232/422/485 Pinout:PORT1-4(RJ-45) RJ-45 RS-232 RS-422 RS-485 PIN1 TXD PIN2 RXD PIN3 GND PIN4 PIN5 T+ 485+ PIN6 T- 485- PIN7 R+ PIN8 R- MODEL ATC-2004 TCP/IP TO RS-232/422/485 CONVERTER User s Manual 1.1 Introduction The ATC-2004 is a 4 Port RS232/RS485 to TCP/IP converter integrated with a robust system and network management features

More information

Produkt-Datenblatt. Technische Daten, Spezifikationen. MEsstechnik fängt mit ME an. www.meilhaus.com. Kontakt

Produkt-Datenblatt. Technische Daten, Spezifikationen. MEsstechnik fängt mit ME an. www.meilhaus.com. Kontakt Produkt-Datenblatt Technische Daten, Spezifikationen Kontakt Technischer und kaufmännischer Vertrieb, Preisauskünfte, Angebote, Test-Geräte, Beratung vor Ort: Tel: (0 81 41) 52 71-0 FAX: (0 81 41) 52 71-129

More information

One Port Serial Server Users Manual Model ESP901, ESP901E

One Port Serial Server Users Manual Model ESP901, ESP901E One Port Serial Server Users Manual Model ESP901, ESP901E Documentation Number: ESP901-2303 International Headquarters B&B Electronics Mfg. Co. Inc. 707 Dayton Road -- P.O. Box 1040 -- Ottawa, IL 61350

More information

NPort 5110 Series User s Manual

NPort 5110 Series User s Manual First Edition, December 2004 www.moxa.com/product Moxa Technologies Co., Ltd. Tel: +886-2-8919-1230 Fax: +886-2-8919-1231 Web: www.moxa.com MOXA Technical Support Worldwide: support@moxa.com.tw The Americas

More information

TCP/IP Converter DDS EX-9132 Operation Manual for 8051 Series

TCP/IP Converter DDS EX-9132 Operation Manual for 8051 Series TCP/IP Converter DDS EX-9132 Operation Manual for 8051 Series First Edition, March 2005 Table of Contents 1. Introduction 3 Overview 4 Package Checklist 5 Block Diagram 6 Features 7 Product Specifications

More information

NPort 5100 Series User s Manual

NPort 5100 Series User s Manual First Edition, June 2006 www.moxa.com/product MOXA Technologies Co., Ltd. Tel: +886-2-8919-1230 Fax: +886-2-8919-1231 Web: www.moxa.com MOXA Technical Support Worldwide: support@moxa.com The software described

More information

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter BIT COMMANDER Serial RS232 / RS485 to Ethernet Converter (Part US2000A) Copyrights U.S. Converters 1 Contents Overview and Features... 3 Functions..5 TCP Server Mode... 5 Httpd Client Mode.5 TCP Auto mode....6

More information

IP SERIAL DEVICE SERVER

IP SERIAL DEVICE SERVER IP SERIAL DEVICE SERVER ( 1 / 2 / 4 serial port ) Installation guide And User manual Version 1.0 1Introduction... 5 1.1Direct IP mode...5 1.2Virtual COM mode...5 1.3Paired mode...6 1.4Heart beat... 6

More information

MODBUS TCP to RTU/ASCII Gateway. User s Manual

MODBUS TCP to RTU/ASCII Gateway. User s Manual MODBUS TCP to RTU/ASCII Gateway User s Manual 1 INTRODUCTION... 1 1.1 FEATURES... 2 1.2 PRODUCT SPECIFICATIONS... 3 1.3 DEFAULT SETTINGS... 4 2 MAKING THE HARDWARE CONNECTIONS... 5 2.1 POWER CONNECTION...

More information

TK700 +70 C -25 C 95% RH EMC TK701G TK701U TK704G TK704U TK704W. TK-Series Cellular Router

TK700 +70 C -25 C 95% RH EMC TK701G TK701U TK704G TK704U TK704W. TK-Series Cellular Router +70 C -25 C 95% RH EMC TK701G TK701U TK704G TK704U TK704W The industrial 2G GPRS- and 3G UMTS routers offered by Welotec enables the access to Ethernet devices or a local network remotely via mobile network

More information

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter ICS-2 S15 Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter Cost Effective Solution for RS-232 / RS-422 / RS-485 to Industrial Ethernet Application PLANET ICS-210x series Smart Media Converter

More information

IPG/7700 Hardware Manual SYSTECH. Document number 80-001099-7 Revision A

IPG/7700 Hardware Manual SYSTECH. Document number 80-001099-7 Revision A IPG/7700 Hardware Manual SYSTECH C O R P O R A T I O N Document number 80-001099-7 Revision A Created 2010, and Protected Under the U.S. Copyright Act of 1976. Copyright 2010, SYSTECH Corporation All Rights

More information

NPort 5200 Series User s Manual

NPort 5200 Series User s Manual User s Manual Eighth Edition, January 2013 www.moxa.com/product 2013 Moxa Inc. All rights reserved. User s Manual The software described in this manual is furnished under a license agreement and may be

More information

TDP43ME NetPS. Network Printer Server. Control Center. for Ethernet Module

TDP43ME NetPS. Network Printer Server. Control Center. for Ethernet Module Panduit Corp. 2010 TDP43ME NetPS PA26306A01 Rev. 01 11-2010 Network Printer Server Control Center for Ethernet Module NOTE: In the interest of higher quality and value, Panduit products are continually

More information

1 Serial RS232 to Ethernet Adapter Installation Guide

1 Serial RS232 to Ethernet Adapter Installation Guide Installation Guide 10/100 Mbps LED (amber color ) Link/Activity LED (green color ) 1. Introduction Thank you for purchasing this 1-port RS232 to Ethernet Adapter (hereinafter referred to as Adapter ).

More information

Dominion PX. General Questions. What is Dominion PX (PX)?

Dominion PX. General Questions. What is Dominion PX (PX)? Dominion PX Question General Questions What is Dominion PX (PX)? Is Raritan new to the rack power distribution unit market? Can the PX be used as a stand-alone device? Does PX work with Raritan s CommandCenter

More information

Atop Technologies, Inc. 1-port Modbus Gateway MB5001C/MB5001C-Sis

Atop Technologies, Inc. 1-port Modbus Gateway MB5001C/MB5001C-Sis Atop Technologies, Inc. 1-port Modbus Gateway MB5001C/MB5001C-Sis User s Manual Version 1.0 Updated on 2010/07/28 Tel: 886-3-5508137 Fax: 886-3-5508131 http://www.atop.com.tw Important Announcement The

More information

Broadband Router ESG-103. User s Guide

Broadband Router ESG-103. User s Guide Broadband Router ESG-103 User s Guide FCC Warning This equipment has been tested and found to comply with the limits for Class A & Class B digital device, pursuant to Part 15 of the FCC rules. These limits

More information

GV-Data Capture V3 Series User's Manual

GV-Data Capture V3 Series User's Manual GV-Data Capture V3 Series User's Manual Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. 2006 GeoVision, Inc. All rights

More information

Network Management Card. User Manual

Network Management Card. User Manual User Manual 1 Contents Contents 2 Chapter 1 Overview 3 1.1 NMC package contents 4 1.2 NMC CD Resources 4 1.3 Features 4 1.4 NMC Applications 5 Chapter 2 NMC parameters setting via serial COM port 6 2.1

More information

RS-232/422/485, Power over Ethernet

RS-232/422/485, Power over Ethernet IP-COM-M IP-COMi-M IP-COM-M PoE IP-COMi-M PoE RS-232 RS-232/422/485 RS-232, Power over Ethernet RS-232/422/485, Power over Ethernet Edition: September 2012 The computer programs provided with the hardware

More information

2-Port RS232/422/485 Combo Serial to USB2.0 Adapter (w/ Metal Case and Screw Lock Mechanism) Installation Guide

2-Port RS232/422/485 Combo Serial to USB2.0 Adapter (w/ Metal Case and Screw Lock Mechanism) Installation Guide 2-Port RS232/422/485 Combo Serial to USB2.0 Adapter (w/ Metal Case and Screw Lock Mechanism) Installation Guide 1. Introduction Thank you for purchasing this 2-Port RS232/422/485 Combo Serial to USB Adapter.

More information

Unpacking the Product. Rack Installation. Then, use the screws provided with the equipment rack to mount the firewall in the rack.

Unpacking the Product. Rack Installation. Then, use the screws provided with the equipment rack to mount the firewall in the rack. About This Guide This guide contains step-by-step instructions for setting up the D-Link DFL-260E/860E Firewall. Please note that the model you have purchased may appear slightly different from those shown

More information

RS-232/422/485 to 10/100Base-TX Device Server / Managed Media Converter (IRF-633) User s Manual

RS-232/422/485 to 10/100Base-TX Device Server / Managed Media Converter (IRF-633) User s Manual RS-232/422/485 to 10/100Base-TX Device Server / Managed Media Converter (IRF-633) User s Manual COPYRIGHT All rights reserved. No part of this publication may be reproduced, stored in a retrieval system,

More information

Securely manage data center and network equipment from anywhere in the world.

Securely manage data center and network equipment from anywhere in the world. LES1516A LES1532A LES1548A Secure Server with Cisco Pinout Securely manage data center and network equipment from anywhere in the world. To download the user manual, this quick start guide, and software

More information

TRP-C31M MODBUS TCP to RTU/ASCII Gateway

TRP-C31M MODBUS TCP to RTU/ASCII Gateway TRP-C31M MODBUS TCP to RTU/ASCII Gateway User s Manual Printed Feb. 2007 Rev 1.0 Trycom Technology Co., Ltd 1F, No.2-11, Sihu street, Yingge Township, Taipei, Taiwan ROC Tel: 886-2-86781191, Fax: 886-2-86781172

More information

Wireless Router Setup Manual

Wireless Router Setup Manual Wireless Router Setup Manual NETGEAR, Inc. 4500 Great America Parkway Santa Clara, CA 95054 USA 208-10082-02 2006-04 2006 by NETGEAR, Inc. All rights reserved. Trademarks NETGEAR is a trademark of Netgear,

More information

Chapter1. Interface Introduction

Chapter1. Interface Introduction Robustel GoRugged R3000 Quick Guide Chapter1. Interface Introduction 1.1 LED Indicators After inserting the SIM card into the router and power on, the LED indicators status should be as follow when work

More information

RAS-E. Industrial router & RAS server & firewall. User manual Document reference : 9016309-04

RAS-E. Industrial router & RAS server & firewall. User manual Document reference : 9016309-04 RAS-E Industrial router & RAS server & firewall User manual Document reference : 9016309-04 For the firmware version V2.30 and the following versions The RAS-E router is manufactured by ETIC TELECOM 13

More information

Network Management Card

Network Management Card Network Management Card AP9617 AP9618 AP9619 Installation and Quick-Start Manual How to Avoid Equipment Damage Disconnect UPS power You do not need to turn off a Symmetra or a Silcon model UPS to install

More information

1 Mi kołaj Z Mik ar ołaj Z zyc arzy ki cki

1 Mi kołaj Z Mik ar ołaj Z zyc arzy ki cki 1 Mikołaj Zarzycki NAND Flash SD Card Connector 256MB, 8bit I/F Push type, Up to 2GB/12.5Mbps USB Connector 1 x Device 2 x HOST, Dual-port LCD Module KEY Battery Holder 128 x 64 dots matrix structure 4

More information

ATC-2000WF User s Manual

ATC-2000WF User s Manual ATC-2000WF User s Manual The software described in this manual is furnished under a license agreement and may be used only in accordance with the terms of that agreement. Copyright Notice Copyright 2007

More information

Internet-bridge XPort

Internet-bridge XPort Ing. Z.Královský Ing. Petr Štol Perk 457 Okrajová 1356 675 22 STA 674 01 T EBÍ Development & production of control equipment Tel.: 568 870982 Tel.: 568 848179 Visualization, measurement and regulation

More information

LotWan Appliance User Guide USER GUIDE

LotWan Appliance User Guide USER GUIDE LotWan Appliance User Guide USER GUIDE Copyright Information Copyright 2014, Beijing AppEx Networks Corporation The description, illustrations, pictures, methods and other information contain in this document

More information

Atop ABLELink Ethernet-Serial Server GW51C- MAXI

Atop ABLELink Ethernet-Serial Server GW51C- MAXI Atop ABLELink Ethernet-Serial Server GW51C- MAXI User Manual Version 1.1 Updated on 2004/08/18 Tel: 886-3-5508137 Fax: 886-3-5508131 www.atop.com.tw IMPORTANT ANNOUNCEMENT The information contained in

More information

Vantage RADIUS 50. Quick Start Guide Version 1.0 3/2005

Vantage RADIUS 50. Quick Start Guide Version 1.0 3/2005 Vantage RADIUS 50 Quick Start Guide Version 1.0 3/2005 1 Introducing Vantage RADIUS 50 The Vantage RADIUS (Remote Authentication Dial-In User Service) 50 (referred to in this guide as Vantage RADIUS)

More information

RN-XV-RD2 Evaluation Board

RN-XV-RD2 Evaluation Board RN-XV-RD2 Evaluation Board 2012 Roving Networks. All rights reserved. -1.01Version 1.0 9/28/2012 USER MANUAL OVERVIEW This document describes the hardware and software setup for Roving Networks RN-XV-RD2

More information

First Steps. Remote Access Gateway IGW/922. with DIL/NetPC ADNP/9200

First Steps. Remote Access Gateway IGW/922. with DIL/NetPC ADNP/9200 Remote Access Gateway IGW/922 with DIL/NetPC ADNP/9200 First Steps SSV Embedded Systems Dünenweg 5 D-30419 Hannover Phone: +49 (0)511/40 000-0 Fax: +49 (0)511/40 000-40 E-mail: sales@ssv-embedded.de Document

More information

USER MANUAL. PingBrother EPIW104 managed passive poe switch & IP watchdog

USER MANUAL. PingBrother EPIW104 managed passive poe switch & IP watchdog USER MANUAL PingBrother EPIW104 managed passive poe switch & IP watchdog CONTENT Content... 2 Chapter 1... 3 1.1 Preface... 3 1.2 CE mark warning... 3 1.3 FCC warning... 4 Chapter 2... 5 2.1 Physical description...

More information

Prestige 324. Prestige 324. Intelligent Broadband Sharing Gateway. Version 3.60 January 2003 Quick Start Guide

Prestige 324. Prestige 324. Intelligent Broadband Sharing Gateway. Version 3.60 January 2003 Quick Start Guide Prestige 324 Intelligent Broadband Sharing Gateway Version 3.60 January 2003 Quick Start Guide 1 Introducing the Prestige The Prestige is a broadband sharing gateway with a built-in four-port 10/100 Mbps

More information

ENET-710. ENET-710 - Ethernet Module ENET-710 JAN / 06 FOUNDATION

ENET-710. ENET-710 - Ethernet Module ENET-710 JAN / 06 FOUNDATION ENET-710 ENET-710 - Ethernet Module JAN / 06 ENET-710 FOUNDATION E N E T 7 1 0 ME smar www.smar.com Specifications and information are subject to change without notice. Up-to-date address information is

More information

T3 Mux M13 Multiplexer

T3 Mux M13 Multiplexer T3 Mux M13 Multiplexer User Manual [Type the abstract of the document here. The abstract is typically a short summary of the contents of the document. Type the abstract of the document here. The abstract

More information

Linksys WAP300N. User Guide

Linksys WAP300N. User Guide User Guide Contents Contents Overview Package contents 1 Back view 1 Bottom view 2 How to expand your home network 3 What is a network? 3 How to expand your home network 3 Where to find more help 3 Operating

More information

Installation Guide. Wireless N Access Point EAP110/EAP120/EAP220

Installation Guide. Wireless N Access Point EAP110/EAP120/EAP220 Installation Guide Wireless N Access Point EAP110/EAP120/EAP220 CONTENTS Network Topology 01 Hardware Overview 02 Hardware Installation 05 1. Installation Requirements... 05 2. Mounting Bracket... 05

More information

IP Serial Server. User Manual

IP Serial Server. User Manual IP Serial Server IPS-101 (1-port) IPS-102 (2-port) IPS-201 (1-port) IPS-202 (2-port) IPS-204 (4-port) User Manual V2.0 2009.03.09 Page: 1 / 62 Copyright This document contains proprietary information that

More information

User Manual. EtherUSB

User Manual. EtherUSB User Manual EtherUSB USB Ethernet Access Point for PDA V 2.0 Clarinet Systems, Inc. Clarinet Systems, Inc. http://www.clarinetsys.com Page 1 Publication Revision No. Control Table Rev. No. Date Contents

More information

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual 5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual Content Overview... 1 Introduction... 1 Features... 3 Packing List... 4 Safety Precaution... 4 Hardware Description... 5 Front Panel...

More information

Application Note 2. Using the TCPDIAL & TCPPERM Commands to Connect Two TransPort router Serial Interfaces Over TCP/IP.

Application Note 2. Using the TCPDIAL & TCPPERM Commands to Connect Two TransPort router Serial Interfaces Over TCP/IP. Application Note 2 Using the TCPDIAL & TCPPERM Commands to Connect Two TransPort router Serial Interfaces Over TCP/IP. Reverse Telnet or Serial Terminal Server MultiTX feature UK Support March 2014 1 Contents

More information

RN-WIFLY-EVAL-UM. WiFly Evaluation Kit. 2012 Roving Networks. All rights reserved. RN-WIFLY-EVAL-UM Version 1.32r 10/9/2012 USER MANUAL

RN-WIFLY-EVAL-UM. WiFly Evaluation Kit. 2012 Roving Networks. All rights reserved. RN-WIFLY-EVAL-UM Version 1.32r 10/9/2012 USER MANUAL WiFly Evaluation Kit 2012 Roving Networks. All rights reserved. Version 1.32r 10/9/2012 USER MANUAL OVERVIEW This document describes the hardware and software setup for Roving Networks evaluation kits,

More information

Industrial 1 Port RS232/422/485 to Dual Ethernet Serial Device Server

Industrial 1 Port RS232/422/485 to Dual Ethernet Serial Device Server Industrial 1 Port RS232/422/485 to Dual Ethernet Serial Device Server NETRS232485 *actual product may vary from photos DE: Bedienungsanleitung - de.startech.com FR: Guide de l'utilisateur - fr.startech.com

More information

Ethernet Radio Configuration Guide

Ethernet Radio Configuration Guide Ethernet Radio Configuration Guide for Gateway, Endpoint, and Repeater Radio Units April 20, 2015 Customer Service 1-866-294-5847 Baseline Inc. www.baselinesystems.com Phone 208-323-1634 FAX 208-323-1834

More information

User Manual. PePWave Surf / Surf AP Indoor Series: Surf 200, E200, AP 200, AP 400. PePWave Mesh Connector Indoor Series: MC 200, E200, 400

User Manual. PePWave Surf / Surf AP Indoor Series: Surf 200, E200, AP 200, AP 400. PePWave Mesh Connector Indoor Series: MC 200, E200, 400 User Manual PePWave Surf / Surf AP Indoor Series: Surf 200, E200, AP 200, AP 400 PePWave Mesh Connector Indoor Series: MC 200, E200, 400 PePWave Surf AP Series: Surf AP 200-X, E200-X, 400-X PePWave Surf

More information

FWS WiTDM Series KWA-O8800-I User Manual

FWS WiTDM Series KWA-O8800-I User Manual FWS WiTDM Series KWA-O8800-I User Manual Date: 2009 / 04 / 23 Version: 1.0 1 Copyright This user s manual and the software described in it are copyrighted with all rights reserved. No part of this publication

More information

NetProbe Lite. Web Based 8 Channel Sensor Collector. User Manual. Version 1.2

NetProbe Lite. Web Based 8 Channel Sensor Collector. User Manual. Version 1.2 NetProbe Lite Web Based 8 Channel Sensor Collector User Manual Version 1.2 Copyright Information Copyright 2004-2005, Mega System Technologies, Inc. All rights reserved. Reproduction without permission

More information

3.5 EXTERNAL NETWORK HDD. User s Manual

3.5 EXTERNAL NETWORK HDD. User s Manual 3.5 EXTERNAL NETWORK HDD User s Manual Table of Content Before You Use Key Features H/W Installation Illustration of Product LED Definition NETWORK HDD Assembly Setup the Network HDD Home Disk Utility

More information

Prestige 324 Quick Start Guide. Prestige 324. Intelligent Broadband Sharing Gateway. Version V3.61(JF.0) May 2004 Quick Start Guide

Prestige 324 Quick Start Guide. Prestige 324. Intelligent Broadband Sharing Gateway. Version V3.61(JF.0) May 2004 Quick Start Guide Prestige 324 Intelligent Broadband Sharing Gateway Version V3.61(JF.0) May 2004 Quick Start Guide 1 1 Introducing the Prestige The Prestige is a broadband sharing gateway with a built-in four-port 10/100

More information

DEX28-VR3P Quick Installation Guide

DEX28-VR3P Quick Installation Guide DEX28-VR3P Quick Installation Guide DEX28-VR3P PBX DTSs 1 3 5 2 4 6 Procedure to start recording: 1. Connect ODD ports (1, 3 or 5) to PBX (MD110 ELU28 or MX-ONE ELU33 board) 2. Connect EVEN ports (2, 4

More information

Bluetooth to Serial Adapter

Bluetooth to Serial Adapter Bluetooth to Serial Adapter Third Edition, Oct 2007 Version 3.0 771-BTS1009C3-001 Contents 1.0 Features....P.2 2.0 Package Content....P.2 3.0 Hard Drives Requirement.P.2 4.0 Specifications.P.3 5.0 Pin

More information

Manual. IP Sensor and Watchdog IPSW2210. I P S W 2 2 1 0 M a n u a l P a g e 1. Relay Output. Power input. 12VDC adapter LED Indicators. 2 Dry.

Manual. IP Sensor and Watchdog IPSW2210. I P S W 2 2 1 0 M a n u a l P a g e 1. Relay Output. Power input. 12VDC adapter LED Indicators. 2 Dry. IP Sensor and Watchdog IPSW2210 Manual Relay Output Power input 12VDC adapter LED Indicators 1 wire 2 Dry Output Green : Power Yellow: Link temperature & humidity contact inputs LED indicator sensor input

More information

N300 WiFi Range Extender

N300 WiFi Range Extender Model EX2700 User Manual July 2014 202-11395-01 350 East Plumeria Drive San Jose, CA 95134 USA Support Thank you for selecting NETGEAR products. After installing your device, locate the serial number on

More information

Environmental Monitoring Unit

Environmental Monitoring Unit Environmental Monitoring Unit AP9312TH AP9312THi User s Guide Contents Environmental Monitoring Unit Managing the Unit............................ 1 Introduction.................................. 1 Available

More information

Link Link sys E3000 sys RE1000

Link Link sys E3000 sys RE1000 User Guide High Performance Extender Wireless-N Router Linksys Linksys RE1000 E3000Wireless-N Table of Contents Contents Chapter 1: Product Overview 1 Front 1 Top 1 Bottom 1 Back 2 Chapter 2: Advanced

More information

EAP600 SOFTWARE FEATURES. Dual Band Long Range Ceiling Mount Access Point PRODUCT OVERVIEW

EAP600 SOFTWARE FEATURES. Dual Band Long Range Ceiling Mount Access Point PRODUCT OVERVIEW Dual Band Long Range Ceiling Mount Access Point 2.4 GHz + 5GHz 300Mbps + 300Mbps 29dBm AP/WDS/Repeater PRODUCT OVERVIEW is a wireless-11n 600Mbps (300Mbps + 300Mbps) High Power Dual Band concurrent ceiling

More information

How To Check If Your Router Is Working Properly On A Nr854T Router (Wnr854) On A Pc Or Mac) On Your Computer Or Ipad (Netbook) On An Ipad Or Ipa (Networking

How To Check If Your Router Is Working Properly On A Nr854T Router (Wnr854) On A Pc Or Mac) On Your Computer Or Ipad (Netbook) On An Ipad Or Ipa (Networking Chapter 7 Using Network Monitoring Tools This chapter describes how to use the maintenance features of your RangeMax NEXT Wireless Router WNR854T. These features can be found by clicking on the Maintenance

More information

The GV-I/O Box 8 Ports provides 8 inputs and 8 relay outputs, and supports both DC and AC output voltages.

The GV-I/O Box 8 Ports provides 8 inputs and 8 relay outputs, and supports both DC and AC output voltages. GV-I/O Box 8 Ports The GV-I/O Box 8 Ports provides 8 inputs and 8 relay outputs, and supports both DC and AC output voltages. Key Features 8 inputs and 8 outputs are provided. Up to 9 pieces of GV-I/O

More information

GV-Keyboard. User's Manual V2.0

GV-Keyboard. User's Manual V2.0 GV-Keyboard User's Manual V2.0 Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. 2007 GeoVision, Inc. All rights reserved.

More information

MODBUS TCP to RTU/ASCII Gateway

MODBUS TCP to RTU/ASCII Gateway MODBUS TCP to RTU/ASCII Gateway Users Manual Model MODport-101, MODport-102, MODport-104 July 2011 1 INTRODUCTION... 1 1.1 FEATURES... 2 1.2 PRODUCT SPECIFICATIONS... 3 1.3 DEFAULT SETTINGS... 4 2 MAKING

More information

LifeSize Networker Installation Guide

LifeSize Networker Installation Guide LifeSize Networker Installation Guide November 2008 Copyright Notice 2006-2008 LifeSize Communications Inc, and its licensors. All rights reserved. LifeSize Communications has made every effort to ensure

More information

NPort DE-311 Hardware Installation Guide

NPort DE-311 Hardware Installation Guide NPort DE-311 Hardware Installation Guide Fourth Edition, June 2008 www.moxa.com/product 2008 Moxa Inc., all rights reserved. Reproduction without permission is prohibited. NPort DE-311 Hardware Installation

More information

SETUP GUIDE SNMP ALARM ADAPTOR COMPATIBLE WITH SIGMA, RADIAN, TPCMQ, auro-he & BLUEstreak POWER SHELVES

SETUP GUIDE SNMP ALARM ADAPTOR COMPATIBLE WITH SIGMA, RADIAN, TPCMQ, auro-he & BLUEstreak POWER SHELVES SNMP ALARM ADAPTOR COMPATIBLE WITH SIGMA, RADIAN, TPCMQ, auro-he & BLUEstreak POWER SHELVES www.unipowerco.com 2014 UNIPOWER LLC All Rights Reserved NORTH AMERICA 3900 Coral Ridge Drive, Coral Springs,

More information

1 Port RS232 Serial over IP Ethernet Device Server

1 Port RS232 Serial over IP Ethernet Device Server 1 Port RS232 Serial over IP Ethernet Device Server NETRS2321P *actual product may vary from photos DE: Bedienungsanleitung - de.startech.com FR: Guide de l'utilisateur - fr.startech.com ES: Guía del usuario

More information

Gigabit Network Traffic Manager User's Manual

Gigabit Network Traffic Manager User's Manual Gigabit Network Traffic Manager User's Manual We make no warranties with respect to this documentation and disclaim any implied warranties of merchantability, quality, or fitness for any particular purpose.

More information

NPort 5100 Series User s Manual

NPort 5100 Series User s Manual User s Manual Seventh Edition, April 2013 www.moxa.com/product 2013 Moxa Inc. All rights reserved. User s Manual The software described in this manual is furnished under a license agreement and may be

More information

16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide

16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide 16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide 1. Introduction Thank you for purchasing this 16-Port RS232 to USB2.0 High Speed Multi Serial Adapter. It is an

More information

USER MANUAL GUIMGR Graphical User Interface Manager for FRM301/FRM401 Media Racks

USER MANUAL GUIMGR Graphical User Interface Manager for FRM301/FRM401 Media Racks USER MANUAL GUIMGR Graphical User Interface Manager for FRM301/FRM401 Media Racks CTC Union Technologies Co., Ltd. Far Eastern Vienna Technology Center (Neihu Technology Park) 8F, No. 60 Zhouzi St. Neihu,

More information

NMS300 Network Management System

NMS300 Network Management System NMS300 Network Management System User Manual June 2013 202-11289-01 350 East Plumeria Drive San Jose, CA 95134 USA Support Thank you for purchasing this NETGEAR product. After installing your device, locate

More information

Using HyperTerminal with Agilent General Purpose Instruments

Using HyperTerminal with Agilent General Purpose Instruments Using HyperTerminal with Agilent General Purpose Instruments Windows HyperTerminal can be used to program most General Purpose Instruments (not the 531xx series counters) using the RS-232 Serial Bus. Instrument

More information

Cable Connection Procedures for Cisco 1900 Series Routers

Cable Connection Procedures for Cisco 1900 Series Routers CHAPTER 5 Cable Connection Procedures for Cisco 1900 Series Routers This document describes how to connect your Cisco 1941 integrated services router to a power source and to networks and external devices.

More information

How To Set Up Aport 211 On A Pc Or Mac Or Ipa (For Microsoft) With Aport-211 On A Microsoft Mac Or Mac (For Mac) With An Ipa Or Ipo (For Pc Or Ipom

How To Set Up Aport 211 On A Pc Or Mac Or Ipa (For Microsoft) With Aport-211 On A Microsoft Mac Or Mac (For Mac) With An Ipa Or Ipo (For Pc Or Ipom Table of Contents Introduction... 3 LAN... 4 Serial... 4 Software... 5 Power... 5 Environment... 5 Dimension... 5 Panel Layout... 6 Connecting Power... 7 Connecting Ethernet Port... 7 Connecting Serial

More information

SecureLinx Spider Duo Quick Start Guide

SecureLinx Spider Duo Quick Start Guide SecureLinx Spider Duo Quick Start Guide SecureLinx Spider Duo Quick Start Guide SecureLinx Spider Duo QUICK START GUIDE CONTENTS Overview... 2 What s In The Box... 3 Installation and Network Settings...

More information

The GV-I/O Box 16 Ports provides 16 inputs and 16 relay outputs, and supports both DC and AC output voltages.

The GV-I/O Box 16 Ports provides 16 inputs and 16 relay outputs, and supports both DC and AC output voltages. GV-I/O Box 16 Ports The GV-I/O Box 16 Ports provides 16 inputs and 16 relay outputs, and supports both DC and AC output voltages. Key Features 16 inputs and 16 outputs are provided. Up to 9 pieces of GV-I/O

More information

UDS1100 User Guide Part Number 900-417 Revision B June 2006

UDS1100 User Guide Part Number 900-417 Revision B June 2006 UDS1100 User Guide Part Number 900-417 Revision B June 2006 Copyright & Trademark Contacts 2006, Lantronix. All rights reserved. No part of the contents of this book may be transmitted or reproduced in

More information

Chapter 1 Configuring Internet Connectivity

Chapter 1 Configuring Internet Connectivity Chapter 1 Configuring Internet Connectivity This chapter describes the settings for your Internet connection and your wireless local area network (LAN) connection. When you perform the initial configuration

More information

SIP Proxy Server. Administrator Installation and Configuration Guide. V2.31b. 09SIPXM.SY2.31b.EN3

SIP Proxy Server. Administrator Installation and Configuration Guide. V2.31b. 09SIPXM.SY2.31b.EN3 SIP Proxy Server Administrator Installation and Configuration Guide V2.31b 09SIPXM.SY2.31b.EN3 DSG, DSG logo, InterPBX, InterServer, Blaze Series, VG5000, VG7000, IP590, IP580, IP500, IP510, InterConsole,

More information

Welcome. Unleash Your Phone

Welcome. Unleash Your Phone User Manual Welcome Unleash Your Phone For assistance with installation or troubleshooting common problems, please refer to this User Manual or Quick Installation Guide. Please visit www.vonage.com/vta

More information

Powerware Environmental Rack Monitor User s Guide

Powerware Environmental Rack Monitor User s Guide Powerware Environmental Rack Monitor User s Guide FCC Part 15 Class B EMC Statements NOTE This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part

More information

Prestige 314 Read Me First

Prestige 314 Read Me First Prestige 314 Read Me First Console WAN 10M PORT Prestige Rear Panel Connections CONNECTION Use an RS-232 console cable. Use the cable that came with your broadband modem. LAN 10/100M Port Number COMPUTER

More information

xpico User Guide Part Number 900-618 Revision A April 2012

xpico User Guide Part Number 900-618 Revision A April 2012 xpico User Guide Part Number 900-618 Revision A April 2012 Copyright and Trademark 2012 Lantronix. All rights reserved. No part of the contents of this book may be transmitted or reproduced in any form

More information

Connecting the DG-102S VoIP Gateway to your network

Connecting the DG-102S VoIP Gateway to your network Contents of Package: DG-102S VoIP Station Gateway Power adapter CD-ROM, including User s Manual Quick Install Guide Requirements: RS-232 Console Cable Two RJ-45 CAT-5 Straight-Through Cables For more information

More information

How Do I Recover infiniti Remotes and Line Cards?

How Do I Recover infiniti Remotes and Line Cards? How Do I Recover infiniti Remotes and Line Cards? Date: June 26, 2008 Overview This FAQ contains the following information and procedures pertaining to ids Release 6.0.1 and later: Before Attempting to

More information

USER GUIDE AC2400. DUAL BAND GIGABIT Wi Fi ROUTER. Model# E8350

USER GUIDE AC2400. DUAL BAND GIGABIT Wi Fi ROUTER. Model# E8350 USER GUIDE AC2400 DUAL BAND GIGABIT Wi Fi ROUTER Model# E8350 Table of Contents Product overview E8350..................................... 1 Setting Up Your E-Series Router Where to find more help.........................

More information