2 SCHUCH Emergency Light Fittings NEW NEU /25.. Dustproof/waterproof emergency light fitting for wind power stations. Description Series Page Polyester with Diffuser Insulation class II Insulation class I Polyester without Diffuser Insulation class II NEW NEU /... Small shock resistant emergency light fitting for wind power stations. Emergency Light Fittings for Wind Power Stations Insulation class I Emergency Light Power Supply Unit Emergency Light Fitting

3 Dustproof/Waterproof Polyester Emergency Light Fittings of Insulation Class II Series 161/ For illumination of working places and acc. to DIN VDE 0108 for illuminating and identifying escape routes etc. Mechanical Data: Housing: Glass fibre reinforced polyester resin, polyurethane gasket. Diffuser: Injected clear acrylic glass or polycarbonate (PC) each with internal prisms. Closure: External plastic clips (KK). Stainless steel clips (KE) available upon request and at extra charge. Reflector: Glass fibre reinforced polyester resin, that can be suspended or removed. It carries the electrical components which are protected against accidental contact. Connection: 3-pole plug-in terminal. Cable entry: 2 plugs M20 x 1,5. Looping the cable at one small end of the housing upon request and at extra charge. Through wiring system: Up to 5x2,5mm 2 (extra charge). Mounting system: Closed knock-outs for direct ceiling mounting, rubber sealing washers inside each fitting. Wiring diagram maintained operation light switch Wiring diagram maintained operation Electrical Data: (series 161/ only) Incorporated NiCd battery set which is constantly charged and therefore ready for operation any time. Visual monitoring the battery charging process through LED. Electronic deep discharge protection. Re-charging time: 24 hours acc. to EN Luminous flux raising i.e. initially the emergency lamp has got a higher luminous flux. Modes of functioning: Maintained operation = in case of mains failure 1 lamp is switched over to battery operation. In the 2-lamp version (type ) only one lamp will be operating as emergency lighting. Connection voltage: 230V, 50Hz (standard) Ambient temperatures convent. ballast: -5 C up to +30 C (maintained version) -5 C up to +40 C (stand-by version) Ambient temperatures (EVG): -5 C up to +40 C (maintained version) light switch Starting: Connect battery conductor Out of operation: Disconnect battery conductor Stand-by operation: Do not connect L1' Shock resistance test: RK 1,6 / 16A 161/ with battery set T T 38 Type Article no. Lamps/ Flux factor Weight Watts approx. % approx. kg 1 hour emergency operation, with conventional ballasts IP /34/ x T 26/36 W 34 4, /18/1 5) x T 26/36 W 18 4, /22/ x T 26/58 W 22 4, /15/1 5) x T 26/58 W 15 4, /65/ x T 26/18 W 65 3, /38/1 5) 6) x T 26/18 W 38 3, /34/ x T 26/36 W 34 5, /50/ x T 26/36 W 50 7, /18/1 5) 6) x T 26/36 W 18 5, /22/ x T 26/58 W 22 7, /31/ x T 26/58 W 31 7, /15/1 5) 6) x T 26/58 W 15 7,2 Series Series hour emergency operation, with electronic ballast (EVG) /34/1 EVG x T 26/36 W 34 3, /18/1 EVG 4) 5) x T 26/36 W 18 3, /22/1 EVG x T 26/58 W 22 4, /15/1 EVG 4) 5) x T 26/58 W 15 3, /65/1 EVG x T 26/18 W 65 3, /38/1 EVG 4) 5) 6) x T 26/18 W 38 3, /34/1 EVG x T 26/36 W 34 7, /50/1 EVG x T 26/36 W 50 5, /18/1 EVG 4) 5) 6) x T 26/36 W 18 4, /22/1 EVG x T 26/58 W 22 5, /31/1 EVG x T 26/58 W 31 6, /15/1 EVG 4) 5) 6) x T 26/58 W 15 5,6 1) Wiring uncompensated only 2) Ratio effective lamp flux/nominal flux 3) Weights without packing material 4) MA version possible (see further series) 5) 3h emergency operation possible 6) shock proof versions Bitte Subject beachten to technical Sie die changes Hinweise im Technischen Anhang! 202

4 161/ EVG for connection to central power supply unit For connection to group or central battery systems or to an emergency mains for illuminating escape routes, ships or vehicles etc. IP65 Electrical design: Electronic ballasts (230V AC / DC). A double lamp luminaire will be equipped with 2 electronic ballasts, separate lamp circuits and separate connection terminals.! T EVG T 38 Type Article no. Lamps/ Weight Watts approx. kg with electronic ballast (EVG) EVG 2) x T 26/18 W 1, EVG x T 26/36 W 2, EVG x T 26/58 W 3,0 with 2 individual electronic ballasts (EVG/2) EVG/2 2) x T 26/18 W 2, EVG/ x T 26/36 W 2, EVG/ x T 26/58 W 4,0 1) Weights without packing material Further series / equipment for series 161/ only:.../b stand-by system = emergency lighting in case of mains failure only (series with 1 lamp = only).../p button for testing the emergency light function.../3 3 hour emergency operation for series 161/ EVG only: with separate or integrated monitoring module for connection to group or central power supply unit with system for monitoring each individual luminaire. (For any inquiry please indicate the make of the equipment used.) with electronic ballast for voltages: 110V AC/DC, 24V DC Type with legend.../35 for types 161/162.../.. EVG only:.../ma automatic monitoring the emergency light fitting with weekly functioning test and annual opwaking period test according to DIN VDE 0108, indication of the test results by LED (luminescence diode) at the luminaire. For further equipment please see catalogue section Dustproof / Waterproof luminaires of series 161/ Emergency Notleuchten Light Fittings Self adhesive legends.../33 W.../34 W.../35 W for escape route identification acc. to BGV A8 and DIN Sighting distance acc. to EN 1838 and DIN 4844 = 25m. Accessories / Spare Parts Type Article no. Self adhesive legends for series and /125/33 W /125/34 W /125/35 W Emergency exit to the left Emergency exit to the right Emergency exit below For further accessories and spare parts please see catalogue section Dustproof / Waterproof luminaires of series 161/ When ordering any electronic components or battery sets please do always indicate the type nos. of the light fittings. 203 Bitte beachten Sie die Hinweise Subject im to Technischen technical changes Anhang!

5 Dustproof / Waterproof Polyester Emergency Light Fittings of Insulation Class I Series 163/ For illumination of working places and acc. to DIN VDE 0108 for illuminating and identifying any escape routes etc. Mechanical Data: Housing: Glass fibre reinforced polyester resin, polyurethane gasket. Diffuser: Stippled clear acrylic (PMMA) with impact resistant component or polycarbonate (PC), hinged at one side. Closure: External plastic clips (KK). Stainless steel clips (KE) upon request and at extra charge. Reflector: Sheet steel, finished in white, detachable, carrying the electrical components. 'Quick release' turn buckle fasteners for quick installation. Connection: 4-pole connection terminal. Cable entries: At the small front sides and at the upper side of the housing, also for looping the mains cable at one side (types also at the long side), 2 plugs M20. Through wiring system: Up to 7x2,5mm 2 or 5x4mm 2 (extra charge). Mounting system: 2 points for direct ceiling mounting; rubber gaskets and washers inside the fitting. Wiring diagram maintained operation light switch Electrical Data: Incorporated NiCd battery set which is constantly charged and therefore ready for operation at any time. Visual monitoring the battery charging process by LED (luminescence diode). Electronic deep discharge protection. Re-charging time: 24 hours acc. to EN Modes of functioning: Maintained operation = in case of mains failure 1 lamp is switched over to battery operation. Connection voltage: 230V, 50Hz (standard) Ambient temperatures: -5 C up to +30 C (maintained version) -5 C up to +40 C (stand-by version) Ambient temperature (EVG): -5 C up to +40 C (maintained version) Wiring diagram maintained operation light switch Starting: Connect battery conductor Out of operation: Disconnect battery conductor Stand-by operation: Do not connect L1' 163/ with battery set T /... Type Article no. Lamps/ Flux factor-weight Watts Watts approx. % 2) approx. kg 3) 1 hour emergency operation, with conventional ballast /18/ ) 1 x T 26/36 W 18 3, /15/ ) 1 x T 26/58 W 15 4, /38/ x T 26/18 W 38 3, /18/ ) 2 x T 26/36 W 18 5, /15/ ) 2 x T 26/58 W 15 6,6 1 hour emergency operation, with electronic ballast (EVG) /18/1 EVG x T 26/36 W 18 3, /15/1 EVG x T 26/58 W 15 3, /38/1 EVG x T 26/18 W 38 3, /18/1 EVG x T 26/36 W 18 4, /15/1 EVG x T 26/58 W 15 4,9 1) Wiring uncompensated only 2) Ratio effective lamp flux/nominal flux IP65 3) Weights without packing material Series Series Bitte Subject beachten to technical Sie die changes Hinweise im Technischen Anhang! 204

6 163/ EVG for connection to central power supply unit For connection to group or central battery systems or to an emergency mains for illuminating escape routes or for emergency lighting on ships, vehicles etc. IP65 Electrical design: Electronic ballasts (230V AC / DC). A double lamp luminaire will be equipped with 2 electronic ballasts, separate lamp circuits and separate connection terminals.! EVG T 26 Type Article no. Lamps/ Weight Watts approx. kg 1) with electronic ballast (EVG) EVG 2) x T 26/18 W 1, EVG x T 26/36 W 2, EVG x T 26/58 W 2,6 with 2 individual electronic ballasts (EVG) EVG/2 2) x T 26/18 W 2, EVG/ x T 26/36 W 3, EVG/ x T 26/58 W 5,0 1) Weights without packing material Further series / equipment for series 163/ only::.../b stand-by system = emergency lighting in case of mains failure only (series with 1 lamp = only).../p button for testing the emergency light function.../3 3 hour emergency operation Special version for wind power stations (see special data sheet). for series 163/ EVG only: with electronic ballast (EVG) for the following voltages: 110 V DC, 24V DC with separate or integrated monitoring module for connection to group or central battery systems with device for monitoring each individual luminaire.(for any inquiry please indicate the make of the equipment used.). for series 163/ EVG only:.../ma automatic monitoring the emergency light fitting with weekly functioning test and indication of the test results by LED (luminescence diode) at the luminaire For further equipment please see catalogue section Dustproof / Waterproof luminaires of series 163 / Notleuchten für Windkraftanlagen auf Anfrage lieferbar. Emergency Notleuchten Light Fittings Type with legend.../35 Self adhesive legends.../33 W.../34 W.../35 W for escape route identification acc. to BGV A8 and DIN Sighting distance acc. to EN 1838 and DIN 4844 = 25m. Accessories / Spare Parts Type Article no. Self adhesive legends for series and /125/33 W /125/34 W /125/35 W Emergency exit to the left Emergency exit to the right Emergency exit below For further accessories and spare parts please see catalogue section Dustproof / Waterproof luminaires of series 163/ When ordering any electronic components or battery sets please indicate the type nos. of the light fittings. 205 Bitte beachten Sie die Hinweise Subject im to Technischen technical changes Anhang!

7 Polyester Emergency/Escape Sign Light Fittings Series KL B/D In humid, wet and dusty locations, commercial and industrial premises, agricultural buildings, car parks, basements, kitchens, protective locations for civil defence, for illumination and identification of escape routes. Mechanical Data: Housing: Glass fibre reinforced polyester, polyurethane gasket. Difuser: Clear stippled PMMA with impact resistant components, hingeable on both sides. Also available in white (W) or clear (K) PMMA or clear stippled (PC) or clear (K PC). Closure: plastic clips (KK). Stainless steel (KE) upon request and at extra charge. Reflector: Sheet steel finished white, detachable, carrying the electrical components. 'Quick release' turn buckle fasteners allow a quick installation. Connection: 3/4-pole connection terminal. Cable entries: At the small front sides and at the upper side of the housing, also for looping the mains cable at one side, 2 plugs M20. Through wiring system: At extra charge. Mounting system: 2 points for direct ceiling mounting; rubber gaskets and washers inside the fitting. Wiring diagram KL B stand-by Wiring diagram KL D maintained Electrical Data: NiCd battery set - gastight - mounted on the reflector. The battery set is constantly charged and therefore ready for operation at any time. Visual monitoring the battery charging process through LED (luminescence diode). Electronic deep discharge protection. Re-charging time: 24 hours acc. to EN NEW Baureihe LED: 3 x 1W LUXEON Highpower-LED NiMH-Batterie Modes of functioning:... B =stand-by operation = in case of mains failure the lamp is on.... D =maintained operation = in case of mains failure the lamp is switched over to battery operation. Connection voltage: 230V, 50Hz (standard) Ambient temperatures: -5 C up to +30 C (maintained version) -5 C up to +40 C (stand-by version) light switch Starting: Connect battery conductor Out of operation: Disconnect battery conductor Stand-by operation: Do not connect L1' KL B/D / D with battery set T 16 TC-SEL KL TC - L Type Article. Lamps/ Em.- Flux factor Weight no. Watts hours appr.% 2) kg 4) maintained or stand-by version 1) IP /45 KL B/D x T 16/8 W , /36 KL B/D x T 16/8 W , /25 KL B/D x TC-SEL 11 W , /20 KL B/D x TC-SEL 11 W ,4 stand-by version (B) 1) /39 KL B x TC-L 18 W , /46 KL B x TC-L 18 W ,4 maintained version (D) with electronic ballast (EVG) /45 KL D1 EVG x T 16/8 W , /36 KL D3 EVG x T 16/8 W , /25 KL D1 EVG x TC-SEL 11 W , /20 KL D3 EVG x TC-SEL 11 W ,9 1)Wiring uncompensated only 2) Ratio effective lamp flux/nominal flux 3) 4) Weights without packing material NEW KL LED IP 65 Note: An EXIT sign on 2 sides requires 2 light fittings which are connected by means of a ceiling or a wall bracket (see accessories / spare parts). LED Type Article. Lamps/ Em.- Flux factor Weight no. Watts hours appr.% 2) kg 4) W KL LED/1/MA x LED 1 W , W KL LED/3/MA x LED 1 W ,0 Bitte Subject beachten to technical Sie die changes Hinweise im Technischen Anhang! 206

8 KL EVG for connection to central power supply unit IP 65 Series KL SB Series KL ST T 16 TC-SEL TC- L LED KL KL SB KL ST For connection to group or central battery systems with/without monitoring the individual luminaires or for connection to an emergency mains for identifying and illuminating escape routes. Type Article no.. Lamps/ Weight Watts approx. kg 1) with electronic ballast (EVG) KL EVG x T 16/8 W 1, KL EVG x TC-SEL 11 W 1, KL EVG x TC-L 18 W 1,2 with high bay reflector (SB) and electronic ballast (EVG) KL SB EVG x T 16/8 W 1, KL SB EVG x TC-SEL 11 W 1, KL SB EVG x TC-L 18 W 1,3 with low bay reflector (ST) and electronic ballast (EVG) KL ST EVG x T 16/8 W 1, KL ST EVG x TC-SEL 11 W 1, KL ST EVG x TC-L 18 W 1,3 NEW Mechanical Data: Types...S. = with high or low bay reflector. Electrical Data: With electronic ballast (230V AC / DC) W KL LED x LED 1 W 1,1 1) Weights without packing material Series KL with legend! Further series / equipment for series KL B/D only: -.../P button for testing the emergency light function for series KL B. and KL D. EVG: -.../MA automatic monitoring the emergency light fitting with weekly functioning test and indication of the test results by LED (luminescence diode) at the luminaire. for series KL EVG only: - with electronic ballast (EVG) for the following voltages: 110 V DC, 24V DC, 12V DC - with separate or integrated monitoring module for connection to group or central battery systems with device for monitoring each individual luminaire. (For any inquiry please indicate the make of the equipment used.) For further equipment please see catalogue section Dustproof / Waterproof luminaires of series 163 / KL Self adhesive legends green/white 1) 121/33 W 121/34 W 121/35 W for clear stippled or clear covers for escape route identification acc. to BGV A8 and DIN Sighting distance acc. to EN 1838 and DIN 4844 = 30m. 1) not for white opalescent covers Accessories / Spare Parts Type Article no. Spare glasses W K PC K PC Brackets WA WA DA /33 W /34 W /35 W PMMA clear stippled PMMA white opalescent PMMA clear PC clear stippled PC clear wall bracket 45 wall bracket 90 ceiling bracket Standard legends, self adhesive (for clear stippled or clear light fittings) emergency exit left emergency exit right emergency exit below Further legends and wordings upon request. For further accessories and spare parts please see catalogue section Dustproof / Waterproof luminaires of series KL When ordering any electronic components or battery sets please do always indicate the type nos. of the light fittings. Emergency Notleuchten Light Fittings 207 Bitte beachten Sie die Hinweise Subject im to Technischen technical changes Anhang!

9 Small shock resistant Emergency/Escape Sign Light Fittings Series B/D At working places and meeting places, humid and wet rooms, for illuminating and indicating escape routes. Mechanical Data: Housing: White polycarbonate. Diffuser: Injected, clear polycarbonate with internal prisms or white opalescent (W). Multiple hinge at one small side for suspending and unhinging purpose. Captive stainless steel screw on the other side for closing the fitting. Connection: 3- / 4-pole terminal. Cable entries: 1 plug M20 at each of the small sides. Mounting system: 2 points at the upper side of the housing for direct ceiling mounting; rubber gaskets and washers inside the fitting. Wiring diagram D/B maintained/stand-by light switch Wiring diagram B stand-by Electrical Data: (series B/D only) NiCd battery set - gastight - mounted on the reflector. The battery set is constantly charged and therefore ready for operation at any time. Visual monitoring of the battery charging process by LED (luminescence diode). Electronic deep discharge protection. Re-charging time: 24 hours acc. to EN Baureihe LED: 2 x 1W LUXEON Highpower-LED NiMH-Batterie Modes of functioning:... B = stand-by operation = in case of mains failure the lamp is on.... D = maintained operation = in case of mains failure the lamp is switched over to battery operation.... MA = automatic monitoring the emergency light fitting with weekly functioning test and indication of the test results by LED (luminescence diode) at the luminaire. Connection voltage: 230V, 50Hz (standard) Ambient temperatures: -5 C up to +30 C (maintained version) -5 C up to +40 C (stand-by version) B/D IP65 with battery set T 16 TC - L Type Article. Lamps/ Em.- Flux factor Weight no. Watts hours appr.% 2) kg 4) Starting: Connect battery conductor Out of operation: Disconnect battery conductor Stand-by operation: Do not connect L1' /.. B. maintained and stand-by version 1) /45 W B/D x T 16/8 W , /36 W B/D x T 16/8 W ,3 Shock resistance test: RK 1.0 / 10A NEW LED stand-by version /39 W B x TC-L 18 W ,3 stand-by version with automatic monitoring system /17 W B1 MA x TC-L 18 W , /17 W B3 MA x TC-L 18 W , /39 W B1 MA x TC-L 18 W ,3 maintained version with electronic ballast (EVG) and automatic monitoring system /45 W D1 EVG MA x T 16/8 W ,2 1) Wiring uncompensated only 2) Ratio effective lamp flux/nominal flux 3) Also available with MA 4) Weights without packing material IP65 with battery set Type Article. Lamps/ Em.- Flux factor Weight no. Watts hours appr.% 2) kg 4) W LED/1 MA x LED 1 W , W LED/3 MA x LED 1 W ,0 Bitte Subject beachten to technical Sie die changes Hinweise im Technischen Anhang! 208

10 ! EVG for connection to central power supply unit T 16 TC-SEL TC- L LED For connection to group or central battery systems or to emergency mains for illuminating escape routes or for emergency illumination on ships, vehicles etc LL EVG x T 16/8 W W 0, EVG x TC-SEL 11 W 0, EVG x TC-L 18 W 0, EVG 24V DC x TC-SEL 11W 1, EVG 12V DC x TC-SEL 11W 1,0 NEW Type Article no. Lamps/ Weight Watts approx. kg 1 with electronic ballast (EVG) W LED x LED 1W 1,0 1) Weights without packing material Further series / equipment for series B/D only:... P button for testing the emergency light function... EVG with electronic ballast Special version for wind power stations (Please ask for our special data sheet). IP65 Electrical Data: Electronic ballasts (230V AC / DC, 110V DC, 24V DC or 12V DC). A double lamp luminaire will be equipped with 2 electronic ballasts, separate lamp circuits and separate connection terminals. for series EVG only: with conventional ballast 230V, 50Hz with separate or integrated monitoring module for connection to group or central battery systems with device for monitoring each individual luminaire. (For any inquiry please indicate the make of the equipment used.) For further equipment please see catalogue section Dustproof / Waterproof luminaires of series 130 / 131 / Type with standard legend Self adhesive legends for escape route identification acc. to BGV A8 and DIN Sighting distance acc. to EN 1838 and DIN 4844 = 15m. Accessories / Spare Parts Type Article no. Standard legend, self adhesive 265/76/ Note: Further legends and wordings upon request. Emergency Notleuchten Light Fittings For further accessories and spare parts please see catalogue section Dustproof / Waterproof luminaires of series 130/131/ When ordering any electronic components or battery sets please indicate the type nos. of the light fittings. 209 Bitte beachten Sie die Hinweise Subject im to Technischen technical changes Anhang!

11 Dustproof/Waterproof Polyester Emergency Light Fittings of Insulation Class II - without diffuser Series For illumination of working places and acc. to DIN VDE 0108 for illuminating and identifying escape routes etc. Mechanical Data: Housing: Glass fibre reinforced polyester resin. Gasket: Weatherproof, non-ageing and chemically resistant profile gasket. Electrical components: Mounted on the inner side of the suspended polyester lid. Starter easily accessible from outside the fitting. Moisture-proof lampholders with rotating contact system, neoprene gasket. Cable entries: At the small front sides and at the upper side of the housing, also for looping the mains cable at one side. 2 plugs M20. Connection: 3-pole connection terminal. Through wiring system: Up to 5 x 2,5mm 2 possible, at extra charge. Mounting system: Closed knock-outs for direct ceiling mounting; rubber gaskets and washers inside the fitting. Wiring diagram maintained operation light switch Wiring diagram maintained operation Electrical Data: (series175...only) Incorporated NiCd battery set which is constantly charged and therefore ready for operation at any time. Visual monitoring the battery charging process by LED (luminescence diode). Electronic deep discharge protection. Re-charging time: 24 hours acc. to EN Luminous flux raising i.e. initially the emergency lamp has got a higher luminous flux. Only one lamp is operating in the emergency case. Modes of functioning: Maintained operation = in case of mains failure 1 lamp is switched over to battery operation. Connection voltage: 230V, 50Hz (standard) Ambient temperatures: -5 C up to +30 C (maintained version) -5 C up to +40 C (stand-by version) light switch Starting: Connect battery conductor Out of operation: Disconnect battery conductor Stand-by operation: Do not connect L1' Series Series with battery set T 26 Type Article no. Lamps/ Flux factor Weight Watts approx. % 2) approx. kg 3) 1 hour emergency operation, with conventional ballast IP /../ /18/1 3) ) 1 x T 26/36 W 18 2, /15/1 3) ) 1 x T 26/58 W 15 3, /18/ ) 2 x T 26/36 W 18 4, /15/ ) 2 x T 26/58 W 15 5,7 1 hour emergency operation, with electronic ballast (EVG) /18/1 EVG 3) x T 26/36 W 18 2, /15/1 EVG 3) x T 26/58 W 15 2, /18/1 EVG 3) x T 26/36 W 18 3, /15/1 EVG 3) x T 26/58 W 15 2,6 1) Wiring uncompensated only 3) Weights without packing material 2) Ratio effective lamp flux/nominal flux Bitte Subject beachten to technical Sie die changes Hinweise im Technischen Anhang! 210

12 EVG for connection to central power supply unit For connection to group or central battery systems or to an emergency mains for illuminating escape routes, ships or vehicles etc. IP65 Electrical design: Electronic ballast (230V AC / DC, 110V DC, 24V DC). A double lamp luminaire will be equipped with 2 electronic ballasts, separate lamp circuits and separate connection terminals.! EVG T 26 Type Article no. Lamps/ Weight Watts approx. kg 1 with electronic ballast (EVG) EVG 1) x T 26/18 W 0, EVG x T 26/36 W 1, EVG x T 26/58 W 1,6 with 2 individual electronic ballasts (EVG/2) EVG/ x T 26/36 W 1, EVG/ x T 26/58 W 1,8 1) Weights without packing material Further series / equipment for series /.../. only:.../b stand-by system = emergency lighting only in case of mains failure.../3 3 hour emergency operation for series /../. EVG only:.../ma automatic self-monitoring and indication of the results, weekly functioning test and yearly long-time test acc. to DIN VDE for series EVG only: with separate or integrated monitoring module for connection to group or central battery equipment with system for monitoring each individual luminaire. (For any inquiry please indicate the make of the used equipment.). with electronic ballast for special voltages: 110V DC, 24V DC with conventional ballast 230V, 50 Hz for both series: with external reflectors with rotable snap-on reflectors with protective tube S38 or S50 with oval-shaped protective tube S0 also in FF version with through wiring system up to 5x2,5mm 2 with different cable entries up to M25 x 1,5 for fluo tubes of 38mm Ø (with enlargement rings 1681/38) Emergency Notleuchten Light Fittings Accessories / Spare Parts For accessories and spare parts please see catalogue section Dustproof / Waterproof luminaires of series When ordering any electronic components or battery sets please do always indicate the type nos. of the light fittings. 211 Bitte beachten Sie die Hinweise Subject im to Technischen technical changes Anhang!

13 NEW IP40 T x 321 x 77 (102*) x 321 x 77 (102*) (* bei Pendel-, Wandausleger- bzw. Deckenauslegermontage) /3 D1 EVG m 1 x T 16/8 W /3 D3 EVG m 1 x T 16/8 W /7 D1 EVG m 1 x T 16/8 W /7 D3 EVG m 1 x T 16/8 W Bitte Subject beachten to technical Sie die changes Hinweise im Technischen Anhang! 212

14 IP40 T 16 TC-SEL /1 EVG m 1 x T 16/6 W 1, /1 EVG m 1 x TC-SEL 9 W 1, /3 EVG m 1 x T 16/8 W 1, /3 EVG m 1 x TC-SEL 11 W 1, /7 EVG m 1 x T 16/8 W 1, /7 EVG m 1 x TC-SEL 11 W 1,6! Weitere Baureihen / Ausführungen Emergency Notleuchten Light Fittings.../33.../34.../33.../34.../35.../35.../99.../98.../ Bitte beachten Sie die Hinweise im Technischen Anhang!

15 NEW Emergency Light Power Supply Unit Series N As power supply for light fittings with up to 200W which are installed separately from the "N"-device in a different room. It is especially recommended in cases in which the existing environmental conditions prohibit the use of fittings with individual battery sets. Mechanical design: Housing: Polycarbonate, grey (RAL 9006) Battery and electronic device: Each in a separate housing acc. to DIN EN Battery compartment with aeration opening Mounting: Direct wall mounting (borings of Ø 6.0 mm) Installation: Plug-type terminals (up to 2.5mm²) Admissible ambient temperature: -5 C up to +35 C Insulation class: I Attention: Installation of this power supply unit is allowed outside the hazardous area only. Distance between the light fitting and the "N" unit: 500m max.voltage drop to be considered acc. to VDE Wiring diagrams for electronic ballast types: mains unswitched mains switched ligh fittings output interface control input stand by Electrical design: Emergency power supply unit with battery for operating 1 or 2 fluorescent light fittings with electronic ballast (EVG) Emergency light electronic device with deep discharge protection and switchover system for mains/emergency operation As a standard with self monitoring device, performing automatic weekly functional and annual operating period tests. The consumer loads will be monitored by a self- adjusting performance control device. Manual actuation of the functional tests and display of messages and malfunctions via a combined foil touch screen. Interface for remote controlling the operating state via external switch. Interface for malfunction indication Battery set: With maintenance-free lead-battery Modes of operation: Maintained or stand-by operation Maintained operation: Switching to battery operation in case of mains failure. Stand-by operation: Emergency lamp switches on in case of mains failure only. Rated voltage: 230V / 50Hz Suitable for: Fluorescent light fittings with electronic ballast (EVG): For double lamp fittings with double EVG, please consider double consumption or use fittings with 2 EVGs (separating the systems) Note: The EVGs in the light fittings connected to the power supply unit must be suitable for DC and AC operation and for application in an equipment acc. to DIN VDE Light fittings for incandescent lamps. Admissible consumption acc. to the admissible consumption of the fluorescent tubes. N12/... 18Ah N12/... 45Ah N with separate housing each for the inverter and for the battery set inverter IP65 IP54 batterie set IP32 N12/... 12/24Ah N12/... 90Ah Type Article no. Lamps/ Flux factor Weight Watts approx.% 1) appr. kg 2 for light fittings with electronic ballast (EVG)- 1 hour operating N12/118-58/12/1 DC x W 100 7,1 N12/218-36/18/1 DC x W 100 8,8 N12/258/24/1 DC x 58 W ,8 for light fittings with electronic ballast (EVG)- 3 hours operating N12/118-58/45/3 DC x W ,2 N12/218-36/45/3 DC x W ,2 N12/258/90/3 DC x 58 W ,5 1) Ratio effective flux/rated lamp flux 2) Weights without packing material Emergency Light Fittings! Further series / equipment Special version for operating fittings with conventional ballasts with electronic starter with a DC/AC converter which will provide a cascaded 230V / 50Hz AC supply with 80VA. Bitte Subject beachten to technical Sie die changes Hinweise im Technischen Anhang! 214

16 Elektroniks chrank IP54 Batterieschrank IP32 Emergency Notleuchten Light Fittings 215 Bitte beachten Sie die Hinweise Subject im to Technischen technical changes Anhang!

17 Elektroniks chrank IP54 Batterieschrank IP32 Bitte Subject beachten to technical Sie die changes Hinweise im Technischen Anhang! 216

18 Emergency Notleuchten Light Fittings 217 Bitte beachten Sie die Hinweise Subject im to Technischen technical changes Anhang!

Linear Luminaire with LED Series EXLUX 6402/2

Linear Luminaire with LED Series EXLUX 6402/2 > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the

More information

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001 > As wall, ceiling and pendant light fitting or side entry lamp > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened

More information

2.8. Ex-Recess-mounted, ceiling emergency light fittings in compact metal design

2.8. Ex-Recess-mounted, ceiling emergency light fittings in compact metal design .8 Ex-Recess-mounted, ceiling emergency light fittings in compact metal design RLF/RLF-INOX 50 18-58 W / RLF/RLF-INOX 50... N 18-36 W (Zone 1,, 1, ) The explosion-protected lighting concept for clean rooms

More information

7 Lighting Technology

7 Lighting Technology 7 Lighting Technology Series HS6145 For use in Zone 1 and Zone 2 Comply with requirements of Fire Department standard DIN 14 462 Battery state display Deep discharge protection Open circuit monitor Light

More information

Product and functional description

Product and functional description Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected

More information

Watertight Luminaire, surface, 1x18W / 2x18W / 2x24W / 1x36W / 2x36W / 2x54W

Watertight Luminaire, surface, 1x18W / 2x18W / 2x24W / 1x36W / 2x36W / 2x54W Watertight Luminaire, surface, 1x18W / x18w / x4w / 1x36W / x36w / x54w IP67 00 cd/klm 18W 36W 30V/ 50/60Hz 1x18W 5105 0005..-xxx.8 x18w 5105 0001..-xxx 3.8 x4w 5105 0045..-xxx 3.0 x54w 5105 0044..-xxx

More information

e 148... explosion-proof emergency light fittings battery sets for zone 1/21 and zone 2/22 e 187/188... nd 187/188...

e 148... explosion-proof emergency light fittings battery sets for zone 1/21 and zone 2/22 e 187/188... nd 187/188... SCHUCH Explosion - proof Light Fittings SCHUCH Dust- / Waterproof Light Fittings e 148... explosion-proof emergency light fittings with individual battery sets for zone 1/21 and zone 2/22 e 187/188...

More information

HERZ-Thermal Actuators

HERZ-Thermal Actuators HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01

More information

EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications

EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications EXLUX ECOLUX C-LUX LIGHTING 6000 6008 6400 6408 6600 6608 6500 Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications Features: Electronic Ballasts For Fluorescent Bipin

More information

Emergency lighting units EM powerled

Emergency lighting units EM powerled M BASIC 1 W Combined emergency lighting Driver 1 4 W Product description Emergency lighting Driver for manual testing SEV for output voltage < 60 V DC ow-profile casing (21 x 30 mm cross-section) 5-year

More information

Thyristor-controlled power supplies and battery chargers

Thyristor-controlled power supplies and battery chargers Thyristor-controlled power supplies and battery chargers Input voltage: 115 / 230 VAC, single phase, 50 / 60 Hz or 208 / 400 / 480 VAC, three phases, 50 / 60 Hz Output voltage: 12 / 24 / 48 / 60 / 72 /

More information

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm Specifications Features Type REED HALL EFFECT NPN or PNP Applicable Series Configurations Construction Materials Body Mounting Bracket Cable Characteristics Operating Temperature Accuracy All Cylinders

More information

H45 LED - Direct and indirect pendant

H45 LED - Direct and indirect pendant RAL 01 10 00 IP 20 230V 50/60Hz Specifications Direct and indirect light pendant linear luminaire. Aluminium profile. Diffusers in frosted polycarbonate profile. Driver included. Supplied with clear base,

More information

Long sensing range. Most suitable for conveyor lines and parking lot applications. 10 m 32.808 ft (Red LED)

Long sensing range. Most suitable for conveyor lines and parking lot applications. 10 m 32.808 ft (Red LED) NX SERIES Compact Multi-voltage Photoelectric Power Supply Built-in Multi-voltage photoelectric sensor usable worldwide Conforming to ow Voltage and EMC Directive Multi-voltage The NX series can operate

More information

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance SPECIFICATION FOR LOW VOLTAGE SWITCHBOARD SEN I N D E X Description 10 STANDARD TECHNICAL REQUIREMENTS 11 Standards 12 General Operating Conditions 13 General Description Of Switchboard 131 Structure 132

More information

Vario-Series Accessories

Vario-Series Accessories Accessories and spare parts for GMW analogue panel meters and controllers Current Transformers pages 2-9 Shunt Resistors 10-11 Voltage Dividers 12 Power supply for indicator/controllers 13 Blanking Plates

More information

6 LED colours: White Blue Green Red Yellow Amber

6 LED colours: White Blue Green Red Yellow Amber Illuminated contours can be found in many places on petrol stations and buildings of industrial, commercial and service companies. Such light bands visually emphasize the contours of a building during

More information

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply) transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control

More information

Wolflite Safety Handlamp H-251E

Wolflite Safety Handlamp H-251E Wolflite Safety Handlamp H-251E & H-251 Mk1 & Mk2 Wolflite Safety Handlamp H-251E H 18Y H 17 H 31Y H 21A H 30 H 24 H 26 H 19 H 25 H 03 H 15Y H 22 H 104 H 29 H 66 H 13 H 14 H 09 H 12 H 48 H 11 H 62 H 63

More information

Installation Contactors. Technical Catalogue. Type ESB. abb. ABB STOTZ-KONTAKT GmbH 1 2CDC 103002 C0201

Installation Contactors. Technical Catalogue. Type ESB. abb. ABB STOTZ-KONTAKT GmbH 1 2CDC 103002 C0201 Technical Catalogue Installation Contactors Type ESB abb ABB STOTZ-KONTAKT GmbH 1 CDC 10300 C001 ABB STOTZ-KONTAKT GmbH CDC 10300 C001 Low Voltage Products and Systems We ensure safety and comfort for

More information

Electric Rotary Actuator - On/Off or programmable control actuator

Electric Rotary Actuator - On/Off or programmable control actuator Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type

More information

morelux QUALITY HIGH & LOW BAY LIGHTING CATALOGUE 2003/04

morelux QUALITY HIGH & LOW BAY LIGHTING CATALOGUE 2003/04 morelux R QUALITY HIGH & LOW BAY LIGHTING CATALOGUE 2003/04 Shopping malls Restaurant, F& B outlets Shops, corridors UV Stabilized Polycarbonate/ Arcylic reflector Standard E27 base with suspension chain/

More information

Mureva Assembly surface mounted wiring devices

Mureva Assembly surface mounted wiring devices 1.0 Waterproof Assembly surface Switches P124543 P124547 External dimensions : 72 x 72 x 47 mm.. Assembly surface rockers become illuminated using bulbs and indicators in option. They can carry a label

More information

Emergency Lighting Introduction

Emergency Lighting Introduction Emergency Lighting Introduction Introduction Emergency evacuation lighting is designed to automatically provide adequate lighting levels and signage for the safe evacuation of humans from buildings in

More information

Cable Plug acc. to DIN EN 175301-803, Form A

Cable Plug acc. to DIN EN 175301-803, Form A Cable Plug acc. to DIN EN 175301-803, Form A Complete program Contact form 18 mm Also available with LED indicator Optional 4-pin version for pressure switch or impulse valves respectively Versions with

More information

Assisted lift operated 2/2-way solenoid valves Type EV250B

Assisted lift operated 2/2-way solenoid valves Type EV250B MAKING MODERN LIVING POSSIBLE Data sheet Assisted lift operated 2/2-way solenoid valves Type EV250B EV250B with assisted lift can operate from zero and up to 10 bar differential pressure. This 2/2-way

More information

Nightscape High performance floodlights and spotlights for discharge lamps

Nightscape High performance floodlights and spotlights for discharge lamps Nightscape High performance floodlights and spotlights for discharge lamps Nightscape is a range of floodlights and spotlights which offers new possibilities for the architectural illumination of buildings.

More information

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils

More information

2013 Wireless Video Intercom INSTALLATION GUIDE

2013 Wireless Video Intercom INSTALLATION GUIDE 2013 Wireless Video Intercom INSTALLATION GUIDE INDEX System configuration and wiring VL-SWD501 System Component.. 4 VL-SWD501EX wiring schematic diagram VL-SWD501EX wiring type and length... 5.... 6 Door

More information

Features. High Brightness LED Light source

Features. High Brightness LED Light source www.edison-opto.com Solid-State Lighting Series 6W MR16 DATASHEET Features High Brightness LED Light source Ecologically Friendly Energy Efficient General Information... 1 Product Dimensions... 2 Product

More information

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate 1 919 1919P01 1919P03 QBM65/C, QBM75-1U/C Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate QBM751-1/C QBM65/C QBM75/C Highly accurate measurements with calibration

More information

Terminal Boxes Series 8146

Terminal Boxes Series 8146 Series > Enclosures in shock-resistant glass fibre reinforced polyester resin > basic enclosure sizes various heights > Fitted according to the customer's requirements > For terminals up to max. 00 mm

More information

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Order code Series and function 1) Plug socket see page 5.042. MN-06-310-HN-442 Standard coil 1) 441 = 12 V DC, 4.2 W 442 = 24 V DC,

More information

(68.52) X. June 2000 Supercedes February 2000. xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we look @ business differently

(68.52) X. June 2000 Supercedes February 2000. xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we look @ business differently (68.52) X June 2000 Supercedes February 2000 xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM.... we look @ business differently XENEX SYSTEM ARCHITECTURE Note: This schematic is for guidance only please

More information

FIREDEX 2200. Conventional Fire Panels

FIREDEX 2200. Conventional Fire Panels 68 Flexible, high specification system Choice of 1, 2, 4 or 8 zones Simple one-shot auto-reset user test facility Approved to EN54 Maintenance free poly switch circuit protection, with auto reset Class

More information

Industrial plastic LED light fittings Industrial metal LED light fittings Emergency LED light fittings

Industrial plastic LED light fittings Industrial metal LED light fittings Emergency LED light fittings 15 CONTENTS Industrial plastic LED light fittings Industrial metal LED light fittings Emergency LED light fittings FUTURA 6 PERUN LED 46 LED EMERGENCY 82 FUTURA 8 PERUN LED 48 HELIOS LED 84 FUTURA - CHEMICALLY

More information

Digital inductive conductivity transmitter

Digital inductive conductivity transmitter Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections

More information

LED MACHINE ILLUMINATIONS

LED MACHINE ILLUMINATIONS white LED light industrial-suited housing energy-efficient ipf electronic gmbh Kalver Straße 25-27 58515 Lüdenscheid Germany fon +49 (0) 2351/9365-0 fax +49 (0) 2351/936519 e-mail: info@ipf-electronic.com

More information

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles Clear Glass Sensor Optimum Sensor for Detecting Transparent Glass and Plastic Bottles E3S-CR67/62 Retroreflective Sensor smoothly detects 5-mm gaps. Detects transparent bottles that have a lens effect.

More information

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM INSTALLATION MANUAL Protec Fire Detection PLC, Protec House, Churchill Way, Nelson, Lancashire, BB9 6RT. Telephone: +44 (0) 1282 717171 Fax: +44 (0) 1282 717273

More information

13 SERIES. Electronic step relays 10-16 A 13.81 13.91

13 SERIES. Electronic step relays 10-16 A 13.81 13.91 13 Electronic step relays 10-16 A 13 13.81 - Electronic step relay - Rail mount - 1 Pole 13.91 - Electronic step relay and timing step relay Switch box mount - 1 Pole Fixed time (10 minutes) timing function

More information

How To Read A Pipe From A Sensor

How To Read A Pipe From A Sensor Liquid Level Sensor Installation on pipes. Sensing by means electrostatic capacity and is not influenced by the color of the pipe or liquid. Available in 8 to mm dia. and to mm dia. models to enable sensing

More information

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x.16.6.1, 2CDG 110 1xx R0011

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x.16.6.1, 2CDG 110 1xx R0011 , 2CDG 110 1xx R0011 SA/S 8.16.6.1 2CDC 071 006 S0010 The 16/20 A Switch actuators are modular installation devices in Pro M Design for installation in the distribution board. The devices are especially

More information

RESOLUX / HIGHLITE/ COMPACT LINE Technology Lighting as its best. Designed and produced in Germany

RESOLUX / HIGHLITE/ COMPACT LINE Technology Lighting as its best. Designed and produced in Germany RESOLUX / HIGHLITE/ COMPACT LINE Technology Lighting as its best. Designed and produced in Germany RESOLUX 505 RESOLUX 650 RESOLUX 720 / 730 / 750 Application Suitable for high switching frequencies as

More information

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009 Climasys Thermal Management System Schneider Electric Universal Enclosures 2009 Schneider Electric Universal Enclosures The specialist in sealed equipment What is the mission of Schneider Electric Universal

More information

Lumolux S CHARACTERISTICS / ADVANTAGE. System of protection. 524 mm - 1871 mm. G = Borosilicate glass. 2 x 8 W - 58 W

Lumolux S CHARACTERISTICS / ADVANTAGE. System of protection. 524 mm - 1871 mm. G = Borosilicate glass. 2 x 8 W - 58 W Lumolux S System of protection Series Length Protection tube IP67 70 mm 524 mm - 1871 mm K = PMMA G = Borosilicate glass Power Voltage Luminous 2 x 8 W - 58 W 24 V / 230 V 770-4800 Lumen CHARACTERISTICS

More information

LED control gear. LED control gear

LED control gear. LED control gear Overview System overview Product overview compact Product overview linear / area Product overview constant voltage / constant current Product / function matrix Page 10 Page 12 Page 13 Page 14 Page 15 Compact

More information

Morgue refrigeration unit

Morgue refrigeration unit Morgue refrigeration unit The Morgue refrigeration units are made of sturdy, self-supporting walls, floor and ceiling elements. They are delivered in separate components and are to be assembled on site

More information

Power Supply and Indicator Unit Type 5024-1. Fig. 1 Type 5024-1. Mounting and Operating Instructions EB 9539 EN

Power Supply and Indicator Unit Type 5024-1. Fig. 1 Type 5024-1. Mounting and Operating Instructions EB 9539 EN Power Supply and Indicator Unit Type 5024-1 Fig. 1 Type 5024-1 Mounting and Operating Instructions EB 9539 EN Edition October 2003 Application 1 Application The Type 5024-1 Power Supply and Indicator Unit

More information

Series 8146/5-V37 and Series 8150/5-V37

Series 8146/5-V37 and Series 8150/5-V37 www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection

More information

High protection factor luminaires

High protection factor luminaires High protection factor luminaires 2 OVER 60 YEARS EXPERIENCE In damp and/or highly soiled spaces you will require enclosed luminaires. ETAP has more than 60 years experience in this field. The result:

More information

RY2 miniature industrial relays

RY2 miniature industrial relays 6 RY2 Relays of general application For plug-in sockets, 35 mm rail mount acc. to PN-EN 60715 or on panel mounting Flat insert connectors - faston x 0,5 mm Recognitions, certifications, directives: RoHS,

More information

Nightspot A2 Floodlights for LEDs and high pressure discharge lamps

Nightspot A2 Floodlights for LEDs and high pressure discharge lamps Nightspot A2 Nightspot A2 Floodlights for LEDs and high pressure discharge lamps Nightspot floodlights are available with rotationally symmetrical reflectors in different sizes for metal halide lamps and

More information

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.

More information

ALARMLINE ANALOGUE Linear Heat Detection System

ALARMLINE ANALOGUE Linear Heat Detection System ALARMLINE ANALOGUE Alarmline Analogue sensor cable senses temperature variations by continuously monitoring the resistance of specially doped N.T.C. polymeric insulation. A change in temperature produces

More information

www.sebury.com.cn Digital Keypad Use s Manual

www.sebury.com.cn Digital Keypad Use s Manual K3 K4 www.sebury.com.cn Digital Keypad Use s Manual Contents Introduction Introduction Specifications Intramural Interface Circuit 3 Mounting 3 Wiring 5 Power UP 7 Engineer Programming Mode 7 The K3/K4

More information

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x.16.2.1, 2CDG1101xxR0011

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x.16.2.1, 2CDG1101xxR0011 Technical Data 2CDC505051D0205 ABB i-bus KNX Product description Switch Actuators SA/S x.16.2.1, 16 A are modular installation devices in ProM design for installation in the distribution board. They are

More information

EXPLOSION-PROOF EMERGENCY LIGHTING FIXTURE FOR FLUORESCENT LAMP EVF-..-EL SERIES

EXPLOSION-PROOF EMERGENCY LIGHTING FIXTURE FOR FLUORESCENT LAMP EVF-..-EL SERIES EXPLOSION-PROOF EMERGENCY LIGHTING FIXTURE FOR FLUORESCENT LAMP EVF-..-EL SERIES Gas explosion protection II 2G Ex d IIC T6 Gb (suitable for Zone1 and Zone 2) Dust explosion protection II 2D Ex tb IIIC

More information

System Manual 1+n technology Issue 2013

System Manual 1+n technology Issue 2013 System Manual 1+n technology Issue 2013 Contents 1 1+n technology System description 3 2 Safety remarks 3 3 Configuration, conductor lengths 1+n technology 4-5 Overview 6 4 Device overview Door loudspeakers,

More information

Floodlight Range Installation Guide

Floodlight Range Installation Guide SPARTAN Floodlight Range Installation Guide CML13ATEX3007 IEC Ex CML14.0001 This installation guide provides instructions for installing the Infra-Red and White-Light SPARTAN SPX series of explosion protected

More information

LED High Bay Light 100W

LED High Bay Light 100W LED High Bay Light 100W CRI: Life Hours: LED Count: Net Weight: 100W 7,527lm (5,500K-6,000K) 70 20.25in(D) Reflector 140 Up to 50,000 hrs 1 High Power 10x10 LED Array Hanging Loop -40-113 -277VAC 1.00

More information

Medical Lighting. XL4 Patient Light

Medical Lighting. XL4 Patient Light Medical Lighting XL4 Patient Light The XL4 is the new ergonomically designed, energy efficient patient light from EDL Lighting Limited. Its purpose is to cover a spectrum of applications within the Healthcare

More information

N20xxA, N34xxA NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING AND 2-POSITION CONTROL

N20xxA, N34xxA NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING AND 2-POSITION CONTROL N2xxA, N34xxA NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING AND 2-POSITION CONTROL SPECIFICATIONS Supply voltage N224A / N3424A N223A / N3423A PRODUCT DATA 24 Vac 15%, 5/6 Hz 23 Vac 15%,

More information

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv)

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv) Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv) Order code Series and function M-05-310-HN-442 Standard coil HN at ports 2 + 4 HN at ports

More information

Dialight. Vigilant LED High Bay - UL for Indoor and Outdoor Industrial Applications

Dialight. Vigilant LED High Bay - UL for Indoor and Outdoor Industrial Applications Dialight Vigilant LED High Bay - UL for Indoor and Outdoor Industrial Applications Vigilant LED High Bay - UL for Indoor and Outdoor Industrial Applications Case Study: Rockline Case Study (Manufacturing)

More information

of the LED control gear Compact dimming Uconverter LCAI 55W 900mA 1750mA ECO SR ECO series

of the LED control gear Compact dimming Uconverter LCAI 55W 900mA 1750mA ECO SR ECO series Uconverter LCAI 55W 900mA 1750mA ECO SR ECO series Product description Independent dimmable LED control gear Constant current LED control gear Output current adjustable between 900 1,750 ma Max. output

More information

sensors Miniature Sensors - S100 The universal miniature photoelectric sensor

sensors Miniature Sensors - S100 The universal miniature photoelectric sensor Miniature Sensors - S1 The universal miniature photoelectric sensor Two threaded front mounting holes Two slotted rear mounting holes Anti-tampering sensor (no adjustment) Standard optic functions and

More information

97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve 9700 NAMUR series, / & / > > Port size: G/, / NPT, NAMUR Interface > > Crossover-free switching > > Main application: Single and double acting actuators > > / way valve usable as / way valve > > Manual

More information

ISL-540 TBTS SERIES D EMERGENCY LIGHTING EQUIPMENT

ISL-540 TBTS SERIES D EMERGENCY LIGHTING EQUIPMENT P.O. BOX 11846 TUCSON, AZ 85734 (520) 294-3292 FAX (520) 741-2837 www.iotaengineering.com INSTRUCTION MANUAL IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always

More information

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG 110 084 R0011

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG 110 084 R0011 , 2CDG 110 084 R0011 2CDC 071 112 F0008 The Fan Coil Actuator is a modular installation device (MDRC) in pro M design. It is intended for installation in the distribution board on 35 mm mounting rails.

More information

Electronic ballasts for fluorescent lamps Products for special applications. PC BASIC, 4 28 W Electronic ballast for system output < 25 W

Electronic ballasts for fluorescent lamps Products for special applications. PC BASIC, 4 28 W Electronic ballast for system output < 25 W T5 TC-DEL TC-SEL TC-TEL TC-DD PC BASIC, 4 28 W Electronic ballast for system output < 25 W Product description CELMA Energy Efficiency Index A2 / A3 Nominal life time up to 50,000 h (at ta 50 C with a

More information

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications Compact size and high performance for the most challenging detection applications Compact dimensions (14x42x25 mm) Background suppression for transparent and shiny objects High speed contrast sensor up

More information

Switch Actuator, 8-fold, 10 A, MDRC AT/S 8.10.1, GH Q631 0075 R0111

Switch Actuator, 8-fold, 10 A, MDRC AT/S 8.10.1, GH Q631 0075 R0111 , GH Q631 0075 R0111 The 8-fold switch actuator is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via a bus terminal. In the event of bus voltage failure,

More information

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps Solar Home System User Manual AEHSHS0110W2L Solar Home System 2 Lamps All rights reserved Specifications subject to change without prior notice 2 Dear Customer, Thank you for purchasing Schneider Electric

More information

Signaling Lights. LH Series Surface Mount Indicators. Part Numbers. Jumbo Dome (one color) Jumbo Dome (two color)

Signaling Lights. LH Series Surface Mount Indicators. Part Numbers. Jumbo Dome (one color) Jumbo Dome (two color) Innovative indicators in a slim & stylish design. uces installation space. LH Series Surface Mount Indicators Key features of the LH series include: Direct mounting on surfaces such as panels, aluminum

More information

LED HIGHBAY COMMERCIAL & INDUSTRIAL DESIGNED MANUFACTURED AND WARRANTED IN AUSTRALIA

LED HIGHBAY COMMERCIAL & INDUSTRIAL DESIGNED MANUFACTURED AND WARRANTED IN AUSTRALIA COMMERCIAL & INDUSTRIAL LED HIGHBAY DESIGNED MANUFACTURED AND WARRANTED IN AUSTRALIA Experience counts Established in 2004, Aqualuma is a privately owned company based on the Gold Coast in Queensland,

More information

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current. Application : The transducer RISH CON - CA/CV (Fig.1) converts a sinusoidal AC Current or AC Voltage into a load independent DC Current or a load independent DC Voltage proportional to the measured value.

More information

HID/FLOODLIGHT: ATEX/IECEx FLAMEPROOF. Applications

HID/FLOODLIGHT: ATEX/IECEx FLAMEPROOF. Applications Applications Powerful, efficient floodlights for large areas such as industrial complexes and ship loading areas. Rated for use in hazardous areas. Features Highly efficient, integrally ballasted floodlight.

More information

Solenoid Valve Island Type 3965

Solenoid Valve Island Type 3965 Solenoid Valve Island Type 365 for the control of pneumatic actuators General The Type 365 Solenoid Valve Island is a compact solution for the centralized control of pneumatic actuators in chemical and

More information

Single sub-base valve

Single sub-base valve solenoid valves Mini-valves 10 mm Electrical connection... Mounting... Port sizes... Rated temperature... Fluid... Working pressure... Nominal flow... Pneumatic connections Voltage... Power... NC poppet

More information

Contents. Additional Hella Products White Noise Back-up Alarms Switches Camera Systems. Technical Data Hella Test Standards IP Ratings

Contents. Additional Hella Products White Noise Back-up Alarms Switches Camera Systems. Technical Data Hella Test Standards IP Ratings Contents 2 3 4 6 8 11 12 16 35 36 72 75 76 81 82 93 96 104 112 116 118 119 120 121 122 124 Background Information Why Work Lamps? Legal Notes Four Technologies Compared Information on Lighting Technology

More information

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection

More information

Thermal-Magnetic Circuit Breaker 3120-...-M1-..

Thermal-Magnetic Circuit Breaker 3120-...-M1-.. Thermal-Magnetic Circuit Breaker -...-M-.. Description Single or two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 34). The addition of a magnetic tripping

More information

DALI DIM/CONVERTER CONTROL (DC NV) 1 10V (0-10 V) analog DALI Converter with (Multi-) Sensor-control and 1 and 2-Switch dim functions

DALI DIM/CONVERTER CONTROL (DC NV) 1 10V (0-10 V) analog DALI Converter with (Multi-) Sensor-control and 1 and 2-Switch dim functions DAI DIM/COVERTER COTRO (DC V) 1 10V (0-10 V) analog DAI Converter with (Multi-) Sensor-control and 1 and 2-Switch dim functions Dim-and Switch Functions: The DAI Dim/Converter Control DC V is suitable

More information

DuroSite Series LED High Bay for Indoor and Outdoor Industrial Applications. Patent Pending

DuroSite Series LED High Bay for Indoor and Outdoor Industrial Applications. Patent Pending Patent Pending DuroSite Series LED High Bay for Indoor and Outdoor Industrial Applications DuroSite Series LED High Bay Features & Benefits L70 rated for >100,000 hours @ 25 C ambient 5 year full performance

More information

HP UPS R1500 Generation 3

HP UPS R1500 Generation 3 HP UPS R1500 Generation 3 Installation Instructions Part Number 650952-001 NOTE: The rating label on the device provides the class (A or B) of the equipment. Class B devices have a Federal Communications

More information

DALI RC BASIC SO. Control unit Operating instructions

DALI RC BASIC SO. Control unit Operating instructions DALI RC BASIC SO Control unit Operating instructions Contents Safety... 4 General instructions 4 Safety instructions 4 Description... 5 Purpose and application 5 Function 5 Light control 5 Brightness

More information

Photovoltaic Solar Energy Unit EESFB

Photovoltaic Solar Energy Unit EESFB Technical Teaching Equipment Photovoltaic Solar Energy Unit EESFB Products Products range Units 5.-Energy Electronic console PROCESS DIAGRAM AND UNIT ELEMENTS ALLOCATION Worlddidac Member ISO 9000: Quality

More information

Nightspot High performance floodlights for discharge lamps and LEDs

Nightspot High performance floodlights for discharge lamps and LEDs Nightspot High performance floodlights for discharge lamps and LEDs Design: Roy Fleedwood The Nightspot series of floodlights comes in three sizes and with rotationally symmetrical reflectors: - Nightspot

More information

LED Driver Compact dimming. Udriver LCAI 100W 900mA 1750mA ECO SR ECO series

LED Driver Compact dimming. Udriver LCAI 100W 900mA 1750mA ECO SR ECO series Udriver LCAI 100W 900mA 1750mA ECO SR ECO series Product description Independent dimmable LED Driver Constant current LED Driver Output current adjustable between 900 1,750 ma Max. output power 100 W Suitable

More information

ABB i-bus KNX SA/S Switch Actuators Product Manual

ABB i-bus KNX SA/S Switch Actuators Product Manual ABB i-bus KNX SA/S Switch Actuators Product Manual Contents Contents Page 1 General... 5 1.1 Using the product manual...5 1.1.1 Structure of the product manual...6 1.1.2 Notes...6 1.2 Product and functional

More information

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw 4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and

More information

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, 14 80 W BASIC T5

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, 14 80 W BASIC T5 T5 TC-L PCA T5 BASIC lp Y II, 1 80 W BASIC T5 Product description Processor-controlled ballast with y II inside Highest possible energy class CELMA EEI = A1 BAT 1 Noise-free precise control via DSI signal,

More information

LED Module SPECIFICATION. LED Module for Modular Platform Series. LED Platform Module with Fin

LED Module SPECIFICATION. LED Module for Modular Platform Series. LED Platform Module with Fin DATE OF ISSUE : March, 2015 1/9 SPECIFICATION for Modular Platform Series Model Name Type Parts No. LED Platform Module with Fin CRI min. 70, 5000K, Flux Rank 3, Type Ⅱ-Short, 351Z Ceramic SL-P7R2E32SZWW

More information

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in 891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC

More information

Twin EL Wall luminaires for halogen lamps or ceramic metal halide lamps

Twin EL Wall luminaires for halogen lamps or ceramic metal halide lamps Twin EL Wall luminaires for halogen lamps or ceramic metal halide lamps The Twin EL series has two reflectors and an adjustable lampholder making it possible to have inversely proportional light distribution

More information

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC

More information

Fluxa Area floodlights for high pressure discharge lamps and LEDs

Fluxa Area floodlights for high pressure discharge lamps and LEDs Fluxa Area floodlights for high pressure discharge lamps and s Fluxa is a series of area floodlights with symmetrical or wide beam reflectors. There are 4 sizes for high pressure discharge lamps or with

More information

FACT SHEET 90 mm premium LED modules Mono and Bi-LED module with low and high beam

FACT SHEET 90 mm premium LED modules Mono and Bi-LED module with low and high beam Front lighting FACT SHEET 90 mm premium LED modules Mono and Bi-LED module with low and high beam Mono LED module with low beam New: Bi-LED module with low and high beam Maintenance free Combines with

More information

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator

More information