R&S RTO and R&S RTE Oscilloscopes Release Notes Firmware Version
|
|
- Dominick Skinner
- 8 years ago
- Views:
Transcription
1 R&S RTO and R&S RTE Oscilloscopes Release Notes Firmware Version These Release Notes are for following models of the R&S RTO and R&S RTE: R&S RTO 1012, order no K12, R&S RTO 1014, order no K14, R&S RTO 1022, order no K22, R&S RTO 1024, order no K24, R&S RTO 1002, order no K02, R&S RTO 1012, order no K12, R&S RTO 1022, order no K22, R&S RTO 1044, order no K44 R&S RTE 1022, order no K22, R&S RTE 1032, order no K32, R&S RTE 1052, order no K52, R&S RTE 1102, order no K02, R&S RTO 1004, order no K04, R&S RTO 1014, order no K14, R&S RTO 1024, order no K24, R&S RTE 1024, order no K24, R&S RTE 1034, order no K34, R&S RTE 1054, order no K54, R&S RTE 1104, order no K04, R&S RTE 1022, order no K22, R&S RTE 1024, order no K24, R&S RTE 1032, order no K32, R&S RTE 1034, order no K34, R&S RTE 1052, order no K52, R&S RTE 1054, order no K54, R&S RTE 1102, order no K62, R&S RTE 1104, order no K64, R&S RTE 1152, order no K72, R&S RTE 1154, order no K74, R&S RTE 1202, order no K82, R&S RTE 1204, order no K Rohde & Schwarz GmbH & Co. KG Muehldorfstr. 15, Munich, Germany Phone: Fax: Internet: Subject to change. R&S is a registered trademark of Rohde & Schwarz GmbH & Co. KG. Trade names are trademarks of the owners. The following abbreviations are used throughout this document: R&S RTO is abbreviated as R&S RTO, R&S RTE as R&S RTE. Release Notes Test and Measurement PAD-T-M: /02.00/CI/1/EN/
2 Current Version and History New Functions Table of Contents 1 Current Version and History New Functions Modified Functions Improvements Known Issues Modifications to the Documentation Firmware Update Preparing the Installation Performing the Firmware Update on the Instrument Performing the Firmware Update without a running oscilloscope application Firmware downgrade Installing Firmware Options Customer Support Release Notes
3 Current Version and History 1 Current Version and History 1.1 New Functions The following table lists the new functions and indicates the version in which the new function was introduced: Version Function Support for Option R&S RTO-K42 - D-PHY Serial Triggering & Decoding Support for Option R&S RTx-K10 - SENT Serial Triggering & Decoding Support for trigger event as Source for action events, for example "Save on Trigger" New toolbar items for PrintScreen, Save SaveSet, Labelling, ClearScreen and Update ReferenceWaveform New toolbar items for Reset, Autoset, Run/Cont and Run Nx Single for easy operation in remote mode Intelligent arrangement of the measurement results in docked mode SmartGrid for ResultDialogs - easy positioning of result dialogs via the touchscreen Different selectable font size for result dialogs and settings dialogs When values are entered in a settings dialog, the digit keyboard dialog includes buttons for settings the values to its Min and Max values The maximum acquisition time is increased to sec/ Div for the RTO and 5000 sec/ Div for the RTE including the RollMode When changing the channel colors all channel icon colors are kept consistent A PRESET action can be undone with the UNDO feature Export of history now can be done including the time stamp for each waveform. This also works for the ultra segmentation mode Reference waveforms can be analyzed without an active channel doing its acquisition Support of automatic firmware update via internet (instruments with operating system Windows 7 Embedded only) Support of current probe R&S RT-ZC05B and R&S RT-ZC10B Ready for future support of current probe R&S RT-ZC Support for Option R&S RTO-K50 - Manchester and NRZ Serial Triggering & Decoding Support for Option R&S RTE-K50 - Manchester and NRZ Serial Triggering & Decoding Support for Option R&S RTO-K52-8b10b Serial Triggering & Decoding Support for Option R&S RTE-K60 - USB 1.0 /1.1 / 2.0 / HSIC Serial Triggering & Decoding Option R&S RTO-K60: Enhanced trigger capabilities (data, etc.) Option R&S RTx-K1: Search on I2C decode Option R&S RTx-K3: Search on LIN decode RTE: Support of Bandwidth Upgrades for RTE models Kxx RTE: Support of additional models RTE: Support of reference waveform offset Support of current probe R&S RT-ZC20B Support of square grid for the X/Y diagram Support for Option R&S RTO-K8 - Ethernet Serial Decoding Support for Option R&S RTE-K8 - Ethernet Serial Decoding Support for Option R&S RTE-K9 - CAN FD Serial Triggering & Decoding Option R&S RTx-K3 / K9: decode results support physical values derived from DBC import Option R&S RTx-K3 / K9: symbolic trigger on physical values derived from DBC import Option R&S RTO-K13: HW recovered clock can be displayed Release Notes
4 Current Version and History Version Function Option R&S RTO-K13: TIE measurements support HW-CDR Support for Option R&S RTO-B103 - Memory Upgrade 200 MSamples per Channel (instruments with operating system Windows 7 Embedded only) Support for Option R&S RTO-B104 - Memory Upgrade 400 MSamples per Channel (instruments with operating system Windows 7 Embedded only) Support for Option R&S RTO-K9 - CAN FD Serial Triggering & Decoding Support for Option R&S RTO-K17 - High Defintion Support for Option R&S RTE-K17 - High Defintion Support for Option R&S RTO-K55 - MDIO Serial Triggering & Decoding Support for Option R&S RTE-K55 - MDIO Serial Triggering & Decoding Option R&S RTx-B1: Export of all digital signals within a digital bus (remote data capture with ASCII format only) The signal bar includes the information about bandfilter width Support of measurements in RollMode Printing of waveforms with white background while keeping the waveform colors Additional unit % for THD measurements available Support of UNCAL and AD overflow status in remote status bit commands RTO: Reference Level settings for "Upper Manual - Lower Absolute Peak" added RTO: Compliance tests (R&S Scope Suite) can be started from the menu bar via Analysis > External Apps (instruments with operating system Windows 7 Embedded only) Multilingual support for Japanese and Korean user interface 1.2 Modified Functions The following table lists the modified functions and indicates the version in which the modification was carried out: Version Function Improved FileOpen/ FileSave Dialog for easy file selection Toolbar Icons updated for improved user experience Print Hardkey directly creates a screenshot image without showing the print settings dialog first Interval trigger is defined by the slope instead of the polartity. The Remote command has been adjusted The position of the floating result dialogs is restored when saving and loading a saveset The default color of a mathematics signal is set to "Spectrogram" if an FFT is included in the mathematics formula Better readability of grid labels when printing with white background RTE: Reference Levels can be defined as absolute values Group result dialogs turned on by default If a waveform is saved because of an event action (for example a mask violation), the filename is always based on the autonaming settings Improved accuracy of jitter measurement histograms Adjustment of N-cycle jitter algorithm with respect to the time difference between adjacent groups of N consecutive cycles Support of Demoboard firmware version V Option R&S RTx-K17: Available maximal digital bandwidth is adapted to analog instrument bandwidth Improved update rate in selected scenarios when time or frequency measurements are active, especially in combination with long record length Release Notes
5 Current Version and History Version Function FindLevel functionality improved for rectangular signals with strong overshoot Closing a measurement result dialog with the Cancel button disables the measurement. In older versions just the visibility was disabled Maximal font size for dialogs is increased When attaching a multilingual keyboard and the keyboard language is changed, there is no impact on the behavior of the Frontpanel keys (instruments with operating system Windows 7 Embedded only) Improved multilingual support for Chinese, German and Russian user interface Single Click on the Horizontal signal bar opens the Horizontal dialog; single click on the Trigger signal bar opens the Trigger Dialog Single Click on a Channel signal bar activates the channel, if the channel is not active. If the channel is already active the channel dialog is opened. 1.3 Improvements The following table lists the eliminated issues and indicates the version in which the issues were eliminated: Version Function In some cases single FFT frames showed deviations during the modification of FFT settings. This issue is fixed In some cases, "Oven cold" was indicated with the R&S RTx-B4 option even though the oven was in operating temperature, This issue is fixed LimitLine violations as action items is supported in RunContinous Mode Improved accuracy for AutoZero functionality, especially for HD-mode Option R&S RTx-B1: Binary display for I²C and SPI when using MSO is fixed Option R&S RTx-B1: The slope is correctly taken into account in delay measurements In some cases, when the frequency span of the FFT math function was considerably smaller than the RBW, the firmware stopped responding. This issue is fixed The logic of the math function "greater than" / "less than" was not always accurate enough. This issue is fixed Fixed delay measurement function for edge count direction "from last" RTx-K1: Fixed duplicated byte occurrence if frame is incomplete If folders for data export contained a dot in their name, a new folder was created with every export. This issue is fixed In some cases the label font size was reset when restarting the instrument. This issue is fixed RTO: When loading SaveSets with reference level settings for "Upper Manual - Lower Absolute Peak" being active, the upper manual value was not loaded correctly. This issue is fixed In some cases the RTx firmware did not respond any more when the instrument was connected via a remote desktop connection and serial protocols were activated. This issue is fixed RTx-K31: In some cases the RTx firmware did not respond any more when a SaveSet was loaded, that had Harmonic Measurements turned on. This issue is fixed In roll mode zooming, scaling and moving was not possible in stop mode before the first acquisition was completed. This issue is fixed Option R&S RTx-K3 / K9: Symbolic display supports rounded integer values whereas the trigger settings support a resolution of 0.1. This issue is fixed Fixed option key issue RTE: In same cases the grid labels were not well readable in printouts with white background. This issue is fixed. Release Notes
6 Current Version and History Version Function In some cases the grid configuration was not recalled correctly from SaveSets with FFT diagrams. This issue is fixed Reference waveforms could not always be disabled after AutoSet. This issue is fixed Correct display of result lines of duty cycle measurements 1.4 Known Issues The following table lists the known issues and indicates since which version the issue could be observed: Since Function None 1.5 Modifications to the Documentation Revision History: Date Release Notes Revision Changes Support for Option R&S RTO-K42 - D-PHY Serial Triggering & Decoding Support for Option R&S RTx-K10 - SENT Serial Triggering & Decoding Service pack related to math function "greater than" / "less than" Release of R&S RTO-K50, R&S RTO-K52, R&S RTE-K50 and R&S RTE-K RTE: Support of Bandwidth Upgrades for RTE models Kxx Support of additional R&S RTE models Correct handling of remote desktop connection when serial protocols are activated Support of current probe R&S RT-ZC20B Service pack related to option key issue Release of R&S RTO-K8, R&S RTE-K8, R&S RTE-K9, TIE on HW-CDR Release of R&S RTO-B103, R&S RTO-B104, R&S RTO-K9, R&S RTO-K17, R&S RTE-K17, R&S RTO-K55 and R&S RTE-K55 Release Notes
7 Firmware Update 2 Firmware Update Firmware updates for the R&S RTO and R&S RTE are available as a single download from the Rohde&Schwarz web page or The installation file for R&S RTO and R&S RTE with Windows 7 is named Setup_Rtx_V _x64.exe. The installation will be rejected, if the installation file is used on an RTO instrument with Windows XP. The installation file for R&S RTO with Windows XP is named Setup_Rto_V _x86.exe. The installation will be rejected, if the installation file is used on an RTO instrument with Windows 7. After the update to version RTx V the instrument will start with preset instrument settings. To check the installed firmware version select Setup from the File menu and switch to the system tab. The firmware version is shown in the upper left corner of this dialog. Important Notice: On R&S RTO with Windows XP updates from a firmware version below to or higher require an additional download file from the Rohde&Schwarz web page or This installation file is named RTO-GraphicDriverUpdate-1.01.msi. To check, if the latest graphics driver version is installed on the instrument R&S RTO with Windows XP, change to the desktop of the instrument. The desktop is available by selecting the item Minimize Application of the File menu. Open the context menu of the main window with a right mouse click and select the menu item Graphics Properties. The following dialog box shall appear: Release Notes
8 Firmware Update If the dialog box on the screen looks different to the one above, an old driver is installed. Select the button Options and Support. A menu appears below. Select the item Information Center of this menu. On the right side a list of properties appears. The third property is titled Driver Version: Check the Version number. The latest driver has the version number Because older graphics driver versions may cause firmware crashes it is strongly recommended to install the latest version. 2.1 Preparing the Installation There are several ways how to update the device after downloading the firmware installation file. Please make sure, that the installation file Setup_Rtx_V _x64.exe is used for R&S RTO and R&S RTE with Windows 7. Setup_Rto_V _x86.exe is used for R&S RTO with Windows XP. Using a memory stick: 1. Copy the file(s) to a directory of the memory stick and insert the memory stick into one of the USB sockets of the instrument. Using the remote desktop and copying the installation files to a directory of the instrument: 1. Connect the instrument to your LAN 2. Start the remote desktop on your PC (C:\winnt\system32\mstsc.exe) Release Notes
9 Firmware Update 3. Enter the TCP/IP address of the instrument that you want to update. Ensure that the local resources > drives option is selected and press the Connect button 4. Login to the instrument (user name: instrument and password by default) 5. Copy the firmware installation file and, if necessary, the graphics installation file RTO-GraphicDriverUpdate-1.01.msi from your PC to a new folder on the instrument 6. You can now access this directory with the installation file from the instrument firmware Using a network drive: 1. Connect your instrument to your LAN, and establish a connection to one of your servers (ask your local IT administrator for support) 2. Copy the firmware installation file and, if necessary, the graphics installation file RTO-GraphicDriverUpdate-1.01.msi from your PC to a directory on this server 3. You can now access the directory with the installation file from the instrument firmware 2.2 Performing the Firmware Update on the Instrument The firmware update process is performed with the following steps: 1. Switch the instrument on and wait until the Oscilloscope has resumed operation 2. Ensure that the acquisition mode is not running. If the RUN CONT or the RUN Nx SINGLE key is shining green, press this key to stop the acquisition 3. Press the SETUP key or select Setup from the File menu at the bottom of the screen 4. Select the System tab 5. The selected dialog box contains a box with the title Select setup for firmware update. Press the Button Open within this box. A file selection dialog appears 6. Change the path to the drive and directory which you prepared in the step 2.1 (USB stick directory, remote PC directory or directory on a server) and close the dialog with the Select button 7. The installation starts and a new dialog box appears. Press the Next button to navigate to the selection of the firmware packages. By default all applications should be installed 8. Press the Install button to start the firmware update: The installation continues and the firmware is stopped. After a few minutes the system restarts automatically. Depending on the previously installed firmware version, a reconfiguration of the hardware may be required during the first start of the firmware. In this case, a message box is displayed and the update of the FPGA starts automatically. Do not switch off the instrument during this update! After the update of the FPGA Release Notes
10 Firmware Update the instrument performs another instrument restart automatically. If a special FPGA update is required the instrument must execute a cold boot. In such a case, a message appears on the screen asking to switch off the instrument. Press the Ok button and wait until the instrument is completely switched off. As a final step switch on the instrument. The instrument resumes operation. 9. As mentioned above the upgrade of the RTO from a firmware version less than (e.g x.x, 1.10.x.x or 1.0.x.x) to version or higher requires an additional update. To check the installed firmware version select Setup from the File menu and switch to the system tab. The firmware version is shown at the upper left corner of this dialog. If the version is less than install an additional firmware package for a graphics driver update: a) Download the file RTO-GraphicDriverUpdate-1.01.msi from the RTO home page and copy it to the instrument or to a memory stick b) Stop the instruments firmware with the Item Exit of the File menu c) Uninstall the old graphics driver in the following way: Open the windows control panel from the windows start menu (Start Settings Control panel). Select the icon Add or remove software. After a few seconds a list of all installed software packages appears. Select Intel Graphics Media Accelerator Driver. Additional information for this software appears. Press the button Remove and wait until the process is complete. d) Start the windows explorer on the desktop of the RTO and navigate to the directory with the installation file RTO-GraphicDriverUpdate-1.01.msi e) Double click on this file and wait until the installation is complete. This will take several minutes f) After a few seconds the instrument executes a reboot g) After the reboot an automatic installation will be started to setup the MS.net Framework. During this installation the instrument cannot be used as a normal Oscilloscope. The installation takes about 10 minutes. After the installation is complete another reboot is executed automatically h) After the second reboot the graphics driver update is complete 10. After the firmware update a self alignment is recommended. Select Self alignment from the File menu. Select Start Alignment to start the self alignment procedure. A message box appears to indicate the running alignment procedure. Wait until this message box disappears. This will take several minutes. Now the instrument is ready for operation. 2.3 Performing the Firmware Update without a running oscilloscope application If a firmware update shall be executed without running firmware, the windows explorer can be started. Change the path to the drive and directory prepared in step 2.1. Make a double click on this file and proceed with step 7 to update the instrument firmware. Release Notes
11 Firmware Update 2.4 Firmware downgrade A firmware downgrade is handled like a normal firmware installation with the following exceptions: R&S RTO Firmware downgrade from version 2.0 or higher to version 1.60 or lower is not supported for instruments with Windows 7: A firmware downgrade from version 2.0 or higher to version 1.60 or lower is only possible on RTO instruments with Windows XP. 2.5 Installing Firmware Options The firmware update includes all currently available firmware options. No additional installation is required. A firmware update has no side effects to firmware options already installed. The instructions in this chapter are only needed, if a firmware option is purchased and needs to be enabled on the instrument. Enabling Options by Entering Option Key Codes To activate firmware options, enter a license key for validation. The license key is in the device certificate or delivered as a part of the software package. The process is performed in the following steps: 1. Press the SETUP key. A dialog box appears. Select the SW options tab. The selected tab contains a box with the title Install a new option. There are two ways to install a firmware option: a) If a file including the option key is provided, select Open in the box with the title Install from file. Navigate to the directory containing the option key file. Choose the file and click Select b) If an option key number is provided double click on the data entry filed with the title Enter new option key. A key pad appears. Enter the option key number and press the Enter button. 2. After successful validation the message option key valid is displayed. If the validation failed, the firmware option is not installed. 3. If more than one firmware option shall be installed, step 1 and 2 needs to be repeated several times. 4. Reboot the device or restart the firmware. Release Notes
12 Customer Support 3 Customer Support Technical support where and when you need it For quick, expert help with any Rohde & Schwarz equipment, contact one of our Customer Support Centers. A team of highly qualified engineers provides telephone support and will work with you to find a solution to your query on any aspect of the operation, programming or applications of Rohde & Schwarz equipment. Up-to-date information and upgrades To keep your instrument up-to-date and to be informed about new application notes related to your instrument, please send an to the Customer Support Center stating your instrument and your wish. We will take care that you will get the right information. Europe, Africa, Middle East Phone customersupport@rohde-schwarz.com North America Phone TEST-RSA ( ) customer.support@rsa.rohde-schwarz.com Latin America Phone customersupport.la@rohde-schwarz.com Asia/Pacific Phone customersupport.asia@rohde-schwarz.com China Phone / customersupport.china@rohde-schwarz.com Release Notes
R&S VISA Release Notes Software Version 5.5.4
R&S VISA Release Notes Software Version 5.5.4 2015 Rohde & Schwarz GmbH & Co. KG Muehldorfstr. 15, 81671 Munich, Germany Phone: +49 89 41 29-0 Fax: +49 89 41 29 12-164 E-mail: mailto:info@rohde-schwarz.com
More informationRelease Notes. R&S ZVH4/ZVH8 Cable and Antenna Analyzer
Release Notes Revision: 01 R&S ZVH4/ZVH8 Cable and Antenna Analyzer Firmware Release V1.50 These Release Notes describe the following models and options of the R&S Cable and Antenna Analyzer: R&S Cable
More informationRemote Monitoring and Control of the R&S RTO with a Web Browser Application Note
Remote Monitoring and Control of the R&S RTO with a Web Browser Application Note Products: R&S RTO1012 R&S RTO1014 R&S RTO1022 R&S RTO1024 This application note describes remote operation or monitoring
More informationFirmware Release 4.42 SP2 (XP)
Test and Measurement Division Release Notes (XP) for R&S ESCI Test Receivers with order number: 1166.5950.xx and R&S ESPI Test Receivers with order number: 1164.6407.xx Printed in the Federal Republic
More informationBroadcast Drive Test Software
Broadcasting Release Notes Broadcast Drive Test Software Release Notes Version 03.12 2013 Rohde & Schwarz GmbH & Co. KG 81671 Munich, Germany Printed in Germany Subject to change Data without tolerance
More informationOPERATION MANUAL. MV-410RGB Layout Editor. Version 2.1- higher
OPERATION MANUAL MV-410RGB Layout Editor Version 2.1- higher Table of Contents 1. Setup... 1 1-1. Overview... 1 1-2. System Requirements... 1 1-3. Operation Flow... 1 1-4. Installing MV-410RGB Layout
More informationRemote Monitoring and Control of the R&S FSL with a Web Browser
Rohde & Schwarz Products: R&S FSL3, R&S FSL6, R&S FSL18 Remote Monitoring and Control of the R&S FSL with a Web Browser Application Note This application notes describes remote operation or monitoring
More informationRemote Monitoring and Control of the R&S FSV with a Web Browser
Rohde & Schwarz Products: R&S FSV3, R&S FSV7, R&S FSV13, R&S FSV30 Remote Monitoring and Control of the R&S FSV with a Web Browser Application Note This application note describes remote operation or monitoring
More informationR&S AFQ100A, R&S AFQ100B I/Q Modulation Generator Supplement
I/Q Modulation Generator Supplement The following description relates to the Operating Manuals, version 03 of R&S AFQ100A, and version 01 of R&S AFQ100B. It encloses the following topics: LXI features,
More informationRemote Control of ROMES on Windows 7. Application Note
Remote Control of ROMES on Windows 7 Application Note 1SP15 Products: R&S ROMES R&S TSMW R&S TSMW-Z3 R&S TSMx. Application Note Michael Manert 05.2011-1SP15_0E Table of Contents Table of Contents 1 Introduction...
More informationR&S RTO Digital Oscilloscope Resolving Security Issues When Working in Secure Areas
Digital Oscilloscope Resolving Security Issues When Working in Secure Areas Based upon the user s security requirements, this document describes the Rohde&Schwarz options available to address the user
More informationApple ipad Remote Control for Broadcasting T&M Instruments Application Note
Apple ipad Remote Control for Broadcasting T&M Instruments Marius Schipper 10.2012-7BM82_1E Apple ipad Remote Control for Broadcasting T&M Instruments Application Note Products: R&S DVMS1 / DVMS4 R&S DVSG
More informationUsing R&S FSW for Efficient Measurements on Multi- Standard Radio Base Stations Application Note
Using R&S FSW for Efficient Measurements on Multi- Standard Radio Base Stations Application Note Products: R&S FSW This application note introduces the Multi- Standard Radio Analyzer function of the R&S
More informationUsing R&S NRP-Z Power Sensors with Android TM Handheld Devices. Application Note. Products:
Application Note, P. Diestelhorst, P. Geltinger 8.2013-1MA215_3e Using R&S NRP-Z Power Sensors with Android TM Handheld Devices Products: Application Note R&S NRP-Z This application note describes how
More informationUniversal Simple Control, USC-1
Universal Simple Control, USC-1 Data and Event Logging with the USB Flash Drive DATA-PAK The USC-1 universal simple voltage regulator control uses a flash drive to store data. Then a propriety Data and
More informationTable of Contents. 1. Overview... 3. 1.1 Materials Required. 3 1.2 System Requirements. 3 1.3 User Mode 3. 2. Installation Instructions..
Table of Contents 1. Overview..... 3 1.1 Materials Required. 3 1.2 System Requirements. 3 1.3 User Mode 3 2. Installation Instructions.. 4 2.1 Installing the On Call Diabetes Management Software. 4 2.2
More informationCODESOFT Installation Scenarios
CODESOFT Installation Scenarios NOTES: CODESOFT is a separate install from existing versions of CODESOFT. You will need to make note of your current settings (default directories, etc.) so you can duplicate
More informationCentral Controller G-50A/GB-50A Web Browser Operation Manual (For System Maintenance Engineer)
Mitsubishi Electric Building Air-conditioner Control System Central Controller G-50A/GB-50A Web Browser Operation Manual (For System Maintenance Engineer) Contents 1 Introduction...1 1-1 Conventions Used
More informationUser Guide Win7Zilla
User Guide Win7Zilla Table of contents Section 1: Installation... 3 1.1 System Requirements... 3 1.2 Software Installation... 3 1.3 Uninstalling Win7Zilla software... 3 Section 2: Navigation... 4 2.1 Main
More informationInstruction manual. testo easyheat Configuration and Analysis software
Instruction manual testo easyheat Configuration and Analysis software en 2 General Information General Information This documentation includes important information about the features and application of
More informationQuick Start Using DASYLab with your Measurement Computing USB device
Quick Start Using DASYLab with your Measurement Computing USB device Thank you for purchasing a USB data acquisition device from Measurement Computing Corporation (MCC). This Quick Start document contains
More informationInstrument Software Update Instructions. Keysight X-Series Signal Analyzers (PXA/MXA/EXA/CXA) Upgrading an older version to A.12.
Instrument Software Update Instructions Keysight X-Series Signal Analyzers (PXA/MXA/EXA/CXA) Purpose Upgrading an older version to A.12.09 and above The purpose of this document is to outline the instrument
More informationMoxa Device Manager 2.0 User s Guide
First Edition, March 2009 www.moxa.com/product 2009 Moxa Inc. All rights reserved. Reproduction without permission is prohibited. Moxa Device Manager 2.0 User Guide The software described in this manual
More informationSoftware User Guide UG-461
Software User Guide UG-461 One Technology Way P.O. Box 9106 Norwood, MA 02062-9106, U.S.A. Tel: 781.329.4700 Fax: 781.461.3113 www.analog.com ezlinx icoupler Isolated Interface Development Environment
More informationIDIS Solution Suite. Backup Service. Software Manual. Powered by
Solution Suite Software Manual Backup Service Powered by Before reading this manual This Operation Manual provides instructions for using Solution Suite, a network integration solution enabling remote
More informationIDIS Solution Suite. Backup Service. Software Manual. Powered by
Solution Suite Software Manual Backup Service Powered by Before reading this manual This Operation Manual provides instructions for using Solution Suite, a network integration solution enabling remote
More informationManual Client Management Software HDR50-CMS
Manual Client Management Software HDR50-CMS HDR50-CMS (Client Management Software) A-1. Install HDR50-CMS for Windows PC HDR50-CMS is a program for communication between DVR and PC to control signal and
More informationImagineWorldClient Client Management Software. User s Manual. (Revision-2)
ImagineWorldClient Client Management Software User s Manual (Revision-2) (888) 379-2666 US Toll Free (905) 336-9665 Phone (905) 336-9662 Fax www.videotransmitters.com 1 Contents 1. CMS SOFTWARE FEATURES...4
More informationSpectral and Time-Domain Analysis of Recorded Wave Files on the Audio Analyzer R&S UPV Application Note
1GA66 Thomas Lechner, 1GPM 19.Aug.2014-0e Spectral and Time-Domain Analysis of Recorded Wave Files on the Audio Analyzer R&S UPV Application Note Products: R&S UPV R&S UPV-B2 R&S UPV-K61 R&S UPV-K63 The
More informationivms-4200 Client Software Quick Start Guide V1.02
ivms-4200 Client Software Quick Start Guide V1.02 Contents 1 Description... 2 1.1 Running Environment... 2 1.2 Surveillance System Architecture with an Performance of ivms-4200... 3 2 Starting ivms-4200...
More informationAutomation License Manager
s Contents Product Overview 1 Installation 2 Working with the Automation License Manager 3 Glossary Manual Index 12/2008 A5E02389428-01 Legal information Warning notice system This manual contains notices
More informationUltra Thin Client TC-401 TC-402. Users s Guide
Ultra Thin Client TC-401 TC-402 Users s Guide CONTENT 1. OVERVIEW... 3 1.1 HARDWARE SPECIFICATION... 3 1.2 SOFTWARE OVERVIEW... 4 1.3 HARDWARE OVERVIEW...5 1.4 NETWORK CONNECTION... 7 2. INSTALLING THE
More informationDAS202Tools v1.0.0 for DAS202 Operating Manual
DAS202Tools v1.0.0 for DAS202 Operating Manual DAT102Tools 1.0.0 Manual Table of context 2 Table of Contents 1 General Information... 3 2 PC... Configuration Requirements 3 3 Software Installation... 3
More informationIridium Extreme TM Satellite Phone. Data Services Manual
Iridium Extreme TM Satellite Phone Data Services Manual Table of Contents 1 OVERVIEW... 1 2 HOW IT WORKS... 1 3 BEFORE INSTALLING... 2 4 USB DRIVER INSTALLATION... 3 5 MODEM INSTALLATION AND CONFIGURATION...
More informationHow To Use An Nio V2.2.4.2 (Ios) With A Simioni V2 (V2.3) And V2
Release Notes Revision: 08 R&S ES-SCAN EMI Measurement Software Software Release V2.60 These Release Notes describe the following types and options of the R&S ES-SCAN EMI Measurement Software. R&S ES-SCAN,
More informationNetworking. General networking. Networking overview. Common home network configurations. Wired network example. Wireless network examples
Networking General networking Networking overview A network is a collection of devices such as computers, printers, Ethernet hubs, wireless access points, and routers connected together for communication
More informationDATA PROJECTOR XJ-A146/XJ-A246/XJ-A256
DATA PROJECTOR XJ-A146/XJ-A246/XJ-A256 E Data Projector Wireless Function Guide Be sure to read the precautions in the Setup Guide that comes with the Data Projector. Be sure to keep all user documentation
More informationDUKANE Intelligent Assembly Solutions
PC Configuration Requirements: Configuration Requirements for ipc Operation The hardware and operating system of the PC must comply with a list of minimum requirements for proper operation with the ipc
More informationTopaz Installation Sheet
Topaz Installation Sheet P/N 460924001E ISS 08FEB12 Content Introduction... 3 Recommended minimum requirements... 3 Setup for Internet Explorer:... 4 Topaz installation... 10 Technical support... 14 Copyright
More informationR&S AFQ100A, R&S AFQ100B I/Q Modulation Generator Supplement
I/Q Modulation Generator Supplement The following description relates to the Operating Manuals, version 03 of R&S AFQ100A, and version 01 of R&S AFQ100B. It encloses the following topics: LXI features,
More informationPowerLogic ION Enterprise 6.0
70002-0298-00 06/2009 PowerLogic ION Enterprise 6.0 Power management software User guide Notices This section describes the symbols used in this guide. Danger This alerts you to things that may cause
More informationR&S NRPV Virtual Power Meter Release Notes Application Version 1.8.0
R&S NRPV Virtual Power Meter Release Notes Application Version 1.8.0 2011-2015 Rohde & Schwarz GmbH & Co. KG 81671 Munich, Germany Subject to change Data without tolerance limits is not binding. R&S is
More informationLegal Notes. Regarding Trademarks. 2012 KYOCERA Document Solutions Inc.
Legal Notes Unauthorized reproduction of all or part of this guide is prohibited. The information in this guide is subject to change without notice. We cannot be held liable for any problems arising from
More informationLDCDP 11999.GdW. L force Controls. Ä.GdWä. Software Manual. Industrial PC. WindowsR CE Thin Client. Operating system
L force Controls Ä.GdWä LDCDP 11999.GdW Software Manual Industrial PC WindowsR CE Thin Client Operating system l Please read these instructions before you start working! Follow the enclosed safety instructions.
More informationAccounting Manager. User Guide A31003-P1030-U114-2-7619
Accounting Manager User Guide A31003-P1030-U114-2-7619 Our Quality and Environmental Management Systems are implemented according to the requirements of the ISO9001 and ISO14001 standards and are certified
More information@ptitude Observer. Installation Manual. Part No. 32170700 Revision G
Part No. 32170700 Revision G Installation Manual Copyright 2012 by SKF Reliability Systems All rights reserved. Aurorum 30, 977 75 Lulea Sweden Telephone: +46 (0) 31 337 10 00, Fax: +46 (0) 920 134 40
More informationDATA PROJECTOR XJ-A135/XJ-A145/XJ-A235/ XJ-A245
DATA PROJECTOR XJ-A135/XJ-A145/XJ-A235/ XJ-A245 E Data Projector Wireless Function Guide Be sure to read the precautions in the User s Guide (Basic Operations) that comes with the Data Projector. Be sure
More informationEASE Scan Tool Customers. SECTION I - Installation
Please Install Your EASE Scan Tool DVD Before Installing Any Other Software That Came With Your Package. SECTION I - Installation ATTENTION: Do NOT connect an EASE Vehicle Interface Device to your Computer
More information1. Central Monitoring System Software
1. Central Monitoring System Software 1-1. General information CMS program is an application with which users not only watch and control remote DVRs, but also receive video/audio data or alarm signals
More informationTFA. KlimaLogg Pro. User Manual. Revision: 0.1
TFA KlimaLogg Pro User Manual Revision: 0.1 Table of Contents Overview... 2 Getting Started... 2 Setting up the KlimaLogg Pro device... 2 Installing the USB-Stick... 2 Installation... 2 System Requirements...
More informationUsing SSH Secure Shell Client for FTP
Using SSH Secure Shell Client for FTP The SSH Secure Shell for Workstations Windows client application features this secure file transfer protocol that s easy to use. Access the SSH Secure FTP by double-clicking
More informationSoftware User's Guide
Software User's Guide Brother QL-series The contents of this guide and the specifications of this product are subject to change without notice. Brother reserves the right to make changes without notice
More informationHow To Use A High Definition Oscilloscope
PRELIMINARY High Definition Oscilloscopes HDO4000 and HDO6000 Key Features 12-bit ADC resolution, up to 15-bit with enhanced resolution 200 MHz, 350 MHz, 500 MHz, 1 GHz bandwidths Long Memory up to 250
More informationInstallation and Configuration User's Guide
Dell UPS Management Software Installation and Configuration User's Guide www.kesintisizservis.com Notes NOTE: A NOTE indicates important information that helps you make better use of your software. Information
More informationUser s Manual of DVR DVS Remote Client Software V 4.0.1
User s Manual of DVR DVS Remote Client Software V 4.0.1 Index Version description...4 1 Introduction...8 2 Software Install, Uninstall and use...9 2.1 Install remote client software ver4.0.1...9 2.2 Uninstall
More informationTroubleshooting Sprint Mobile Broadband USB Modem by Novatel Wireless TM (Ovation TM U727)
Troubleshooting Sprint Mobile Broadband USB Modem by Novatel Wireless TM (Ovation TM U727) If you are unable to resolve your issue using the Troubleshooting steps below, please contact Sprint Customer
More informationInstallation and Operation Manual Portable Device Manager, Windows version
Installation and Operation Manual version version About this document This document is intended as a guide for installation, maintenance and troubleshooting of Portable Device Manager (PDM) and is relevant
More informationGetting Started with Vision 6
Getting Started with Vision 6 Version 6.9 Notice Copyright 1981-2009 Netop Business Solutions A/S. All Rights Reserved. Portions used under license from third parties. Please send any comments to: Netop
More informationModel 288B Charge Plate Graphing Software Operators Guide
Monroe Electronics, Inc. Model 288B Charge Plate Graphing Software Operators Guide P/N 0340175 288BGraph (80207) Software V2.01 100 Housel Ave PO Box 535 Lyndonville NY 14098 1-800-821-6001 585-765-2254
More informationNVMS - 1000 USER MANUAL. Version 2.1.0
NVMS - 1000 USER MANUAL Version 2.1.0 Contents 1 Software Introduction... 1 1.1 Summary... 1 1.2 Operation Environment... 1 1.3 Install and Uninstall... 2 1.3.1 Install the Software... 2 1.3.2 Uninstall
More informationAXIS Camera Station Quick Installation Guide
AXIS Camera Station Quick Installation Guide Copyright Axis Communications AB April 2005 Rev. 3.5 Part Number 23997 1 Table of Contents Regulatory Information.................................. 3 AXIS Camera
More informationViewPower. User s Manual. Management Software for Uninterruptible Power Supply Systems
ViewPower User s Manual Management Software for Uninterruptible Power Supply Systems Table of Contents 1. ViewPower Overview... 2 1.1. Introduction...2 1.2. Structure...2 1.3. Applications...2 1.4. Features...2
More informationMovie Cube. User s Guide to Wireless Function
Movie Cube User s Guide to Wireless Function Table of Contents 1. WLAN USB Adapter Connection...3 2. Wireless Setup...4 2.1 Infrastructure (AP)...5 2.2 Peer to Peer (Ad Hoc)...7 2.3 Settings for PC...8
More information1. Central Monitoring System Software
1. Central Monitoring System Software 1-1. General information CMS program is an application with which users not only watch and control remote DVRs, but also receive video/audio data or alarm signals
More informationUC2 Video Surveillance Client. User Manual V1.0.6
UC2 Video Surveillance Client User Manual V1.0.6 MODIFY STEPS VERSION WRITER STATUS DESCRIPTION DATE V1.0.3 BRIAN A Add access mode function 2011-4-11 V1.0.4 BRIAN A Add PTZ and user role and so on 2011-4-23
More informationVirtual Office Remote Installation Guide
Virtual Office Remote Installation Guide Table of Contents VIRTUAL OFFICE REMOTE INSTALLATION GUIDE... 3 UNIVERSAL PRINTER CONFIGURATION INSTRUCTIONS... 12 CHANGING DEFAULT PRINTERS ON LOCAL SYSTEM...
More informationSharp Remote Device Manager (SRDM) Server Software Setup Guide
Sharp Remote Device Manager (SRDM) Server Software Setup Guide This Guide explains how to install the software which is required in order to use Sharp Remote Device Manager (SRDM). SRDM is a web-based
More informationData Management Software. CL-S10w. Installation Guide
Data Management Software CL-S10w Installation Guide Safety Warning Please read this manual and the instrument and computer manual carefully beforehand and use the software properly and safely. Official
More information13 Managing Devices. Your computer is an assembly of many components from different manufacturers. LESSON OBJECTIVES
LESSON 13 Managing Devices OBJECTIVES After completing this lesson, you will be able to: 1. Open System Properties. 2. Use Device Manager. 3. Understand hardware profiles. 4. Set performance options. Estimated
More informationRapid Assessment Key User Manual
Rapid Assessment Key User Manual Table of Contents Getting Started with the Rapid Assessment Key... 1 Welcome to the Print Audit Rapid Assessment Key...1 System Requirements...1 Network Requirements...1
More informationTable of Contents. Chapter 5 Backed-up Video Playback & Exportation... 29 5.1 Playing back Backed-up Video... 29 5.2 Exporting Backed-up Video...
inex Backup Table of Contents Chapter 1 Introduction... 1 1.1 System Diagram... 2 Backup Service Registered on Administration Service... 2 Backup Service Registered on Federation Service... 3 Chapter 2
More informationSA-9600 Surface Area Software Manual
SA-9600 Surface Area Software Manual Version 4.0 Introduction The operation and data Presentation of the SA-9600 Surface Area analyzer is performed using a Microsoft Windows based software package. The
More informationGuest PC. for Mac OS X. User Guide. Version 1.6. Copyright 1996-2005 Lismore Software Systems, Ltd. All rights reserved.
Guest PC for Mac OS X Version 1.6 User Guide Copyright 1996-2005 Lismore Software Systems, Ltd. All rights reserved. Table of Contents About Guest PC... 1 About your Virtual Computer... 1 Creating a Virtual
More informationClient Program Installation Guide
Siku Quanshu (Wenyuange Edition) Online Subscription Services Client Program Installation Guide 1. System Requirements The minimum requirements of the Siku Quanshu (Wenyuange Edition) Online Subscription
More informationConfiguring Windows 7 64 bit for AutoVISION
This document will describe how to configure a 64 bit version of Windows 7 Professional, Ultimate or Enterprise to utilize the Windows XP Mode (Virtual PC) capabilities to allow AutoVISION to be used in
More informationTECHNICAL BULLETIN. Configuring Wireless Settings in an i-stat 1 Wireless Analyzer
i-stat TECHNICAL BULLETIN Configuring Wireless Settings in an i-stat 1 Wireless Analyzer Before configuring wireless settings, please enable the wireless functionality by referring to the Technical Bulletin
More informationWireless Presentation System User s Manual
Wireless Presentation System User s Manual (Model Name: WPS-Dongle) Version: 3.0 Date: August 19, 2009 Table of Contents 1. Overview...3 2. Quick Start...4 3. Windows Client Utility...7 3.1 Starting Program...7
More informationDevice Installer User Guide
Device Installer User Guide Part Number 900-325 Revision B 12/08 Table Of Contents 1. Overview... 1 2. Devices... 2 Choose the Network Adapter for Communication... 2 Search for All Devices on the Network...
More informationMAGPOWR Spyder Firmware Update Instruction Manual
MAGPOWR TENSION CONTROL MAGPOWR Spyder Firmware Update Instruction Manual EN Spyder and Spyder-Plus MI 850A324 B COPYRIGHT All of the information herein is the exclusive proprietary property of Maxcess
More informationMaking Basic Measurements. Publication Number 16700-97020 August 2001. Training Kit for the Agilent Technologies 16700-Series Logic Analysis System
Making Basic Measurements Publication Number 16700-97020 August 2001 Training Kit for the Agilent Technologies 16700-Series Logic Analysis System Making Basic Measurements: a self-paced training guide
More informationSUDT AccessPort TM Advanced Terminal / Monitor / Debugger Version 1.37 User Manual
SUDT AccessPort TM Advanced Terminal / Monitor / Debugger Version 1.37 User Manual Version 1.0 - January 20, 2015 CHANGE HISTORY Version Date Description of Changes 1.0 January 20, 2015 Initial Publication
More informationAllworx Installation Course
VPN Hello and welcome. In the VPN section we will cover the steps for enabling the VPN feature on the Allworx server and how to set up a VPN connection to the Allworx System from your PC. Page 1 VPN The
More informationNVMS-1200. User Manual
NVMS-1200 User Manual Contents 1 Software Introduction... 1 1.1 Summary... 1 1.2 Install and Uninstall... 1 1.2.1 Install the Software... 1 2 Login Software... 3 2.1 Login... 3 2.2 Control Panel Instruction...
More informationThe serial port is another kind of transmission mode in some outdated PC as a supplementary in failure of USB transmission.
Page 1 of 21 OWON Oscilloscope Installation and Use Guide Welcome to use Oscilloscope analysis software. The kind of communication software is use to acquire, store, analyze and display the data. The instruction
More informationAdobe Dreamweaver CC 14 Tutorial
Adobe Dreamweaver CC 14 Tutorial GETTING STARTED This tutorial focuses on the basic steps involved in creating an attractive, functional website. In using this tutorial you will learn to design a site
More informationDATACARD Firmware Update Instructions. Contents. Firmware Update Application for Windows Operating Systems. What You Need
DATACARD Firmware Update Instructions Firmware Update Application for Windows Operating Systems Contents What You Need How to Update Using the Go Green Upgrade CD How to Update Using Files Downloaded from
More informationGlobal Image Management System For epad-vision. User Manual Version 1.10
Global Image Management System For epad-vision User Manual Version 1.10 May 27, 2015 Global Image Management System www.epadlink.com 1 Contents 1. Introduction 3 2. Initial Setup Requirements 3 3. GIMS-Server
More informationAppendix A. CMS(Client Management Software)
Appendix A. CMS(Client Management Software) A-1. Install CMS for Windows PC CMS is a program for communication between DVR and PC to control signal and video. Insert the enclosed CD, and go to CD-ROM Drive
More informationAccXES Client Tools 10.0 User Guide 701P41529 May 2004
AccXES Client Tools 10.0 User Guide 701P41529 May 2004 Trademark Acknowledgments XEROX, AccXES, The Document Company, and the identifying product names and numbers herein are trademarks of XEROX CORPORATION.
More informationSoftware Operations Manual
Software Operations Manual Version 5.0 BinMaster 7201 North 98th Street Lincoln, NE 68507 Phone: 402-434-9102 / Fax: 402-434-9133 info@binmaster.com - www.binmaster.com System Requirements PC with 1GHz
More informationAllworx OfficeSafe Operations Guide Release 6.0
Allworx OfficeSafe Operations Guide Release 6.0 No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic, mechanical, photocopy,
More informationUser Guide for Windows 10
User Guide for Windows 10 System requirements E10684 First Edition July 2015 To facilitate a smoother transition from your previous operating system, read the system requirements below before upgrading
More informationInstalling the Microsoft Network Driver Interface
Installing the Microsoft Network Driver Interface Overview This guide explains how to install the PictureTel Live200 Microsoft Network Driver Interface (NDIS) software you have downloaded from PictureTel's
More informationZebraDesigner Pro. User Guide. 13857L-003 Rev. A
ZebraDesigner Pro User Guide 13857L-003 Rev. A 2 2011 ZIH Corp. The copyrights in this manual and the software and/or firmware in the printer described therein are owned by ZIH Corp. and Zebra s licensors.
More information2. PMP New Computer Installation. & Networking Instructions
ONTARIO CHIROPRACTIC ASSOCIATION PATIENT MANAGEMENT PROGRAM PUTTING EXPERIENCE INTO PRACTICE PMP New Computer Installation & Networking Instructions This document provides installation instructions for
More informationFX-BTCVT Bluetooth Commissioning Converter Commissioning Guide
FX-BTCVT Bluetooth Commissioning Converter Commissioning Guide FX-BTCVT-1 (Bluetooth Commissioning Converter) Code No. LIT-12011665 Issued December 5, 2014 Refer to the QuickLIT website for the most up-to-date
More informationGigabyte Management Console User s Guide (For ASPEED AST 2400 Chipset)
Gigabyte Management Console User s Guide (For ASPEED AST 2400 Chipset) Version: 1.4 Table of Contents Using Your Gigabyte Management Console... 3 Gigabyte Management Console Key Features and Functions...
More informationApplication & Quick-Start Guide
Model: CRMWIC Web Intelligent Controller 1 This document will illustrate various ways to connect and use a CRM-WIC as well as programming examples. When connecting CRM-WIC, the installer has several interface
More informationInstalling LearningBay Enterprise Part 2
Installing LearningBay Enterprise Part 2 Support Document Copyright 2012 Axiom. All Rights Reserved. Page 1 Please note that this document is one of three that details the process for installing LearningBay
More informationContents. Hardware Configuration... 27 Uninstalling Shortcuts Black...29
Contents Getting Started...1 Check your Computer meets the Minimum Requirements... 1 Ensure your Computer is Running in Normal Sized Fonts... 7 Ensure your Regional Settings are Correct... 9 Reboot your
More information