Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

Size: px
Start display at page:

Download "Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000"

Transcription

1 Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000 Description Firetrol FTA1000 Full Voltage Fire Pump Controllers are intended for use with electric motor driven fire pumps where the capacity of the power source permits full voltage starting. Full voltage is applied to the motor as soon as the controller is actuated. The controller monitors, displays and records fire pump system information. Full voltage starting is simple and low cost and is preferred whenever the utility or emergency generator set will permit this type of starting. Approvals Firetrol fire pump controllers are listed by Underwriters' Laboratories, Inc., in accordance with UL218, Standard for Fire Pump Controllers, CSA, Standard for Industrial Control Equipment, and approved by Factory Mutual. They are built to meet or exceed the requirements of the approving authorities as well as NEMA and the latest editions of NFPA 20, Installation of Centrifugal Fire Pumps, and NFPA 70, National Electrical Code. Standard Features The following are included as standard with each controller: Voltage surge protector Main Disconnect Switch sized for connected motor horsepower and voltage Fire pump Circuit Breaker Motor contactor Emergency Manual Run Mechanism to mechanically close motor contactor contacts in an emergency condition Built-in Start and Stop push-buttons to bypass automatic start circuits Door mounted display/interface panel featuring a 40 Character Vacuum Fluorescent Display, Membrane Type User Control Push-buttons and easy to read LED Indicators Single handle Isolating Disconnect Switch/Circuit Breaker mechanism POWER ON LED PUMP RUN LED PHASE FAILURE LED PHASE REVERSAL LED LOW PRESSURE LED DELUGE OPEN LED INTERLOCK ON LED TRANSFER SWITCH NORMAL LED (If unit ordered with Automatic Power Transfer Switch) TRANSFER SWITCH EMERGENCY LED (If unit ordered with Automatic Power Transfer Switch) EMERGENCY ISOLATING SWITCH OFF LED (If unit ordered with Automatic Power Transfer Switch) Minimum Run Timer / Off Delay Timer Daylight Savings Time Option Weekly Test Timer Elapsed Time Meter Digital Pressure Display 1.44M Floppy Disk Drive Data Log Event Log (3000 Events) True RMS Metering with simultaneous 3 phase display of amps and volts Disk Error message Disk Near Full message Pressure Error message Motor Over 320% message Local Start message Remote Start message Emergency Start message Fail To Start message Undervoltage message Overvoltage message Low Suction Pressure message High Speed Open Serial Communications Port NEMA Type 2 enclosure

2 SPECIAL ENCLOSURES -T NEMA Type 3R (IEC IP14) -E NEMA Type 4 (IEC IP56) -F NEMA Type 4X (IEC IP56) FTA1000, 1250, 1300 FTA1350, 1500, 1800, G NEMA Type 12 (IEC IP52) CIRCUIT BREAKER OPTION -N Intermediate withstand rating 150,000 Amps RMS Sym. -P High withstand rating 200,000 Amps RMS Sym Note: Intermediate and High withstand ratings may not be available for all horsepowers and voltages. Consult factory for availability. ANTI-CONDENSATION SPACE HEATERS -H 120 Volt Space Heater -J 120 Volt Space Heater With Thermostat -K 120 Volt Space Heater With Humidistat -L 240 Volt Space Heater -M 240 Volt Space Heater With Thermostat -N 240 Volt Space Heater With Humidistat PRESSURE TRANSDUCERS -B psi ( bar) Pressure Transducer for Fresh Water Service -C psi ( bar) Pressure Transducer for Sea Water, Foam or Copper Corrosive Service -D psi ( bar) Pressure Transducer for Sea Water, Foam or Copper Corrosive Service AUTOMATIC POWER TRANSFER SWITCHES (Refer to publication SD900-21) FTA900 - generator set emergency supply FTA901 - bypass isolation switch for generator set emergency supply FTA950 - second utility emergency supply FTA951 - bypass isolation switch for second utility emergency supply ALARMS -AC Extra contacts (normally open & normally closed) for remote indication, pump operating -AF Audible and Visible low pump room temperature alarm -AG Built-in reservoir low alarm -AH Audible low suction pressure alarm -AM Contacts for remote indication, pump fail to start -AV Contacts for remote indication, low pump room temperature -AW Contacts for remote indication, reservoir low -AY Contacts for remote indication, low suction pressure -AZ Low pump room temperature switch, mounted and wired -BW Extra contacts for remote indication, phase failure/phase reversal -BY Contacts for remote indication, pump overload -COM Visible Low suction pressure alarm with manual reset push-button -CTS Built in Low Suction Pressure Alarm Panel (Includes selectable auto/manual reset, audible, visible and remote alarms and mounted and wired pressure switch) -EG Visible relief valve discharge alarm -EH Contacts for remote indication, relief valve discharge -EJ Built-in flow meter on alarm -EK Contacts for remote indication, flow meter on -P Built-in alarm system (Includes visible supervisory voltage normal indication and audible pump operating, phase failure and phase reversal indication) -PB Built-in low system pressure visible alarm with manual reset -PE Contacts for remote indication, low system pressure -PT Built-in alarm system, 220 VAC supervisory power (Includes visible supervisory voltage normal indication and audible pump operating, phase failure and phase reversal indication) -HV Audible alarm device -LVA Visible pump on demand alarm -LW Audible and visible pump on demand alarm (requires (-HV)) -LY Contacts for remote indication, pump on demand (requires (-LVA) or (-LW)) MISCELLANEOUS -DZ Test push-button and solenoid valve* -ED Load shed circuits -EL Series pumping, high zone controller -EM Series pumping, mid zone controller(s) -EN Series pumping, low zone controller -PY Motor space heater output contacts -S Tropicalization -ZPA Customized, annual service display message (when factory programmed or programmed by Firetrol representative during start-up) -ZPB High Quality Impact Printer with paper take-up mechanism Export packaging FTA1000, 1250, 1300 FTA1350, 1500, 1800, 1900 *Weekly Test Timer Standard PD (B)

3 Product Description Part Winding Starting Electric Fire Pump Controllers FTA1250 Description Firetrol FTA1250 Part Winding Starting Fire Pump Controllers can be used where the characteristics of the power source do not permit full voltage starting. The controller monitors, displays and records fire pump system information. When the controller is actuated by the pressure switch, START pushbutton, deluge valve contact, etc., the first contactor closes, connecting one of the motor windings to the line. During starting, the motor will draw approximately 65% of its normal locked rotor current and develop approximately 42% of its normal starting torque. After a time delay, the second contactor closes, connecting the second winding in parallel with the first. The motor then draws its normal running current and develops its rated torque. Approvals Firetrol fire pump controllers are listed by Underwriters' Laboratories, Inc., in accordance with UL218, Standard for Fire Pump Controllers, CSA, Standard for Industrial Control Equipment, and approved by Factory Mutual. They are built to meet or exceed the requirements of the approving authorities as well as NEMA and the latest editions of NFPA 20, Installation of Centrifugal Fire Pumps, and NFPA 70, National Electrical Code. Standard Features The following are included as standard with each controller: Voltage surge protector Main Disconnect Switch sized for connected motor horsepower and voltage Fire pump Circuit Breaker Motor contactor Emergency Manual Run Mechanism to mechanically close motor contactor contacts in an emergency condition Built-in Start and Stop push-buttons to bypass automatic start circuits Door mounted display/interface panel featuring a 40 Character Vacuum Fluorescent Display, Membrane Type User Control Push-buttons and easy to read LED Indicators Single handle Isolating Disconnect Switch/Circuit Breaker mechanism POWER ON LED PUMP RUN LED PHASE FAILURE LED PHASE REVERSAL LED LOW PRESSURE LED DELUGE OPEN LED INTERLOCK ON LED TRANSFER SWITCH NORMAL LED (If unit ordered with Automatic Power Transfer Switch) TRANSFER SWITCH EMERGENCY LED (If unit ordered with Automatic Power Transfer Switch) EMERGENCY ISOLATING SWITCH OFF LED (If unit ordered with Automatic Power Transfer Switch) Minimum Run Timer / Off Delay Timer Daylight Savings Time option Weekly Test Timer Motor Acceleration Timer Elapsed Time Meter Digital Pressure Display 1.44M Floppy Disk Drive Data Log Event Log (3000 Events) True RMS Metering with simultaneous 3 phase display of amps and volts Disk Error message Disk Near Full message Pressure Error message Motor Over 320% message Local Start message Remote Start message Emergency Start message Fail To Start message Undervoltage message Overvoltage message Low Suction Pressure message High Speed Open Serial Communications Port NEMA Type 2 enclosure

4 SPECIAL ENCLOSURES -T NEMA Type 3R (IEC IP14) -E NEMA Type 4 (IEC IP56) -F NEMA Type 4X (IEC IP56) FTA1000, 1250, 1300 FTA1350, 1500, 1800, G NEMA Type 12 (IEC IP52) CIRCUIT BREAKER OPTION -N Intermediate withstand rating 150,000 Amps RMS Sym. -P High withstand rating 200,000 Amps RMS Sym Note: Intermediate and High withstand ratings may not be available for all horsepowers and voltages. Consult factory for availability. ANTI-CONDENSATION SPACE HEATERS -H 120 Volt Space Heater -J 120 Volt Space Heater With Thermostat -K 120 Volt Space Heater With Humidistat -L 240 Volt Space Heater -M 240 Volt Space Heater With Thermostat -N 240 Volt Space Heater With Humidistat PRESSURE TRANSDUCERS -B psi ( bar) Pressure Transducer for Fresh Water Service -C psi ( bar) Pressure Transducer for Sea Water, Foam or Copper Corrosive Service -D psi ( bar) Pressure Transducer for Sea Water, Foam or Copper Corrosive Service AUTOMATIC POWER TRANSFER SWITCHES (Refer to publication SD900-21) FTA900 - generator set emergency supply FTA901 - bypass isolation switch for generator set emergency supply FTA950 - second utility emergency supply FTA951 - bypass isolation switch for second utility emergency supply ALARMS -AC Extra contacts (normally open & normally closed) for remote indication, pump operating -AF Audible and Visible low pump room temperature alarm -AG Built-in reservoir low alarm -AH Audible low suction pressure alarm -AM Contacts for remote indication, pump fail to start -AV Contacts for remote indication, low pump room temperature -AW Contacts for remote indication, reservoir low -AY Contacts for remote indication, low suction pressure -AZ Low pump room temperature switch, mounted and wired -BW Extra contacts for remote indication, phase failure/phase reversal -BY Contacts for remote indication, pump overload -COM Visible Low suction pressure alarm with manual reset push-button -CTS Built in Low Suction Pressure Alarm Panel (Includes selectable auto/manual reset, audible, visible and remote alarms and mounted and wired pressure switch) -EG Visible relief valve discharge alarm -EH Contacts for remote indication, relief valve discharge -EJ Built-in flow meter on alarm -EK Contacts for remote indication, flow meter on -P Built-in alarm system (Includes visible supervisory voltage normal indication and audible pump operating, phase failure and phase reversal indication) -PB Built-in low system pressure visible alarm with manual reset -PE Contacts for remote indication, low system pressure -PT Built-in alarm system, 220 VAC supervisory power (Includes visible supervisory voltage normal indication and audible pump operating, phase failure and phase reversal indication) -HV Audible alarm device -LVA Visible pump on demand alarm -LW Audible and visible pump on demand alarm (requires (-HV)) -LY Contacts for remote indication, pump on demand (requires (-LVA) or (-LW)) MISCELLANEOUS -DZ Test push-button and solenoid valve* -ED Load shed circuits -EL Series pumping, high zone controller -EM Series pumping, mid zone controller(s) -EN Series pumping, low zone controller -PY Motor space heater output contacts -S Tropicalization -ZPA Customized, annual service display message (when factory programmed or programmed by Firetrol representative during start-up) -ZPB High Quality Impact Printer with paper take-up mechanism Export packaging FTA1000, 1250, 1300 FTA1350, 1500, 1800, 1900 *Weekly Test Timer Standard PD (B)

5 Product Description Wye-Delta Open Transition Starting Electric Fire Pump Controllers FTA1300 Description Firetrol FTA1300 Wye-Delta, Open Transition Starting Fire Pump Controllers are used with delta-wound squirrel cage motors. FTA1300 controllers are of the open circuit transition type in which the motor circuit is opened during the transition from start to run. The controller monitors, displays and records fire pump system information. Actuating the controller by the pressure switch, START pushbutton or deluge valve contact closes the start contactor connecting the motor to the line in the wye connection. The motor will draw approximately 33% of its normal inrush current and develop approximately 33% of its normal starting torque. After a time delay, the motor is automatically reconnected in delta, applying full voltage to the motor windings. These controllers are recommended especially for use with generator sets. Approvals Firetrol fire pump controllers are listed by Underwriters' Laboratories, Inc., in accordance with UL218, Standard for Fire Pump Controllers, CSA, Standard for Industrial Control Equipment, and approved by Factory Mutual. They are built to meet or exceed the requirements of the approving authorities as well as NEMA and the latest editions of NFPA 20, Installation of Centrifugal Fire Pumps, and NFPA 70, National Electrical Code. Standard Features The following are included as standard with each controller: Voltage surge protector Main Disconnect Switch sized for connected motor horsepower and voltage Fire pump Circuit Breaker Motor contactor Emergency Manual Run Mechanism to mechanically close motor contactor contacts in an emergency condition Built-in Start and Stop push-buttons to bypass automatic start circuits Door mounted display/interface panel featuring a 40 Character Vacuum Fluorescent Display, Membrane Type User Control Push-buttons and easy to read LED Indicators Single handle Isolating Disconnect Switch/Circuit Breaker mechanism POWER ON LED PUMP RUN LED PHASE FAILURE LED PHASE REVERSAL LED LOW PRESSURE LED DELUGE OPEN LED INTERLOCK ON LED TRANSFER SWITCH NORMAL LED (If unit ordered with Automatic Power Transfer Switch) TRANSFER SWITCH EMERGENCY LED (If unit ordered with Automatic Power Transfer Switch) EMERGENCY ISOLATING SWITCH OFF LED (If unit ordered with Automatic Power Transfer Switch) Minimum Run Timer / Off Delay Timer Daylight Savings Time option Weekly Test Timer Motor Acceleration Timer Elapsed Time Meter Digital Pressure Display 1.44M Floppy Disk Drive Data Log Event Log (3000 Events) True RMS Metering with simultaneous 3 phase display of amps and volts Disk Error message Disk Near Full message Pressure Error message Motor Over 320% message Local Start message Remote Start message Emergency Start message Fail To Start message Undervoltage message Overvoltage message Low Suction Pressure message High Speed Open Serial Communications Port NEMA Type 2 enclosure

6 SPECIAL ENCLOSURES -T NEMA Type 3R (IEC IP14) -E NEMA Type 4 (IEC IP56) -F NEMA Type 4X (IEC IP56) FTA1000, 1250, 1300 FTA1350, 1500, 1800, G NEMA Type 12 (IEC IP52) CIRCUIT BREAKER OPTION -N Intermediate withstand rating 150,000 Amps RMS Sym. -P High withstand rating 200,000 Amps RMS Sym Note: Intermediate and High withstand ratings may not be available for all horsepowers and voltages. Consult factory for availability. ANTI-CONDENSATION SPACE HEATERS -H 120 Volt Space Heater -J 120 Volt Space Heater With Thermostat -K 120 Volt Space Heater With Humidistat -L 240 Volt Space Heater -M 240 Volt Space Heater With Thermostat -N 240 Volt Space Heater With Humidistat PRESSURE TRANSDUCERS -B psi ( bar) Pressure Transducer for Fresh Water Service -C psi ( bar) Pressure Transducer for Sea Water, Foam or Copper Corrosive Service -D psi ( bar) Pressure Transducer for Sea Water, Foam or Copper Corrosive Service AUTOMATIC POWER TRANSFER SWITCHES (Refer to publication SD900-21) FTA900 - generator set emergency supply FTA901 - bypass isolation switch for generator set emergency supply FTA950 - second utility emergency supply FTA951 - bypass isolation switch for second utility emergency supply ALARMS -AC Extra contacts (normally open & normally closed) for remote indication, pump operating -AF Audible and Visible low pump room temperature alarm -AG Built-in reservoir low alarm -AH Audible low suction pressure alarm -AM Contacts for remote indication, pump fail to start -AV Contacts for remote indication, low pump room temperature -AW Contacts for remote indication, reservoir low -AY Contacts for remote indication, low suction pressure -AZ Low pump room temperature switch, mounted and wired -BW Extra contacts for remote indication, phase failure/phase reversal -BY Contacts for remote indication, pump overload -COM Visible low suction pressure alarm with manual reset push-button -CTS Built in Low Suction Pressure Alarm Panel (Includes selectable auto/manual reset, audible, visible and remote alarms and mounted and wired pressure switch) -EG Visible relief valve discharge alarm -EH Contacts for remote indication, relief valve discharge -EJ Built-in flow meter on alarm -EK Contacts for remote indication, flow meter on -P Built-in alarm system (Includes visible supervisory voltage normal indication and audible pump operating, phase failure and phase reversal indication) -PB Built-in low system pressure visible alarm with manual reset -PE Contacts for remote indication, low system pressure -PT Built-in alarm system, 220 VAC supervisory power (Includes visible supervisory voltage normal indication and audible pump operating, phase failure and phase reversal indication) -HV Audible alarm device -LVA Visible pump on demand alarm -LW Audible and visible pump on demand alarm (requires (-HV)) -LY Contacts for remote indication, pump on demand (requires (-LVA) or (-LW)) MISCELLANEOUS -DZ Test push-button with solenoid valve* -ED Load shed circuits -EL Series pumping, high zone controller -EM Series pumping, mid zone controller(s) -EN Series pumping, low zone controller -PY Motor space heater output contacts -S Tropicalization -ZPA Customized, annual service display message (when factory programmed or programmed by Firetrol representative during start-up) -ZPB High Quality Impact Printer with paper take-up mechanism Export packaging FTA1000, 1250, 1300 FTA1350, 1500, 1800, 1900 *Weekly Test Timer Standard PD (B)

7 Product Description Wye-Delta Closed Transition Starting Electric Fire Pump Controllers FTA1350 Description Firetrol FTA1350 Wye-Delta, Closed Transition Starting Fire Pump Controllers are used with delta-wound squirrel cage motors. FTA1350 controllers are of the closed circuit transition type in which the motor circuit remains closed during the transition from start to run. The controller monitors, displays and records fire pump system information. Actuating the controller by the pressure switch, START pushbutton or deluge valve contact closes the start contactor connecting the motor to the line in the wye connection. The motor will draw approximately 33% of its normal inrush current and develop approximately 33% of its normal starting torque. After a time delay, the motor is automatically reconnected in delta, applying full voltage to the motor windings. During this transition, a resistor is connected to each phase, minimizing line disturbances and voltage drop during starting. These controllers are recommended especially for use with generator sets. Approvals Firetrol fire pump controllers are listed by Underwriters' Laboratories, Inc., in accordance with UL218, Standard for Fire Pump Controllers, CSA, Standard for Industrial Control Equipment, and approved by Factory Mutual. They are built to meet or exceed the requirements of the approving authorities as well as NEMA and the latest editions of NFPA 20, Installation of Centrifugal Fire Pumps, and NFPA 70, National Electrical Code. Standard Features The following are included as standard with each controller: Voltage surge protector Main Disconnect Switch sized for connected motor horsepower and voltage Fire pump Circuit Breaker Motor contactor Emergency Manual Run Mechanism to mechanically close motor contactor contacts in an emergency condition Built-in Start and Stop push-buttons to bypass automatic start circuits Door mounted display/interface panel featuring a 40 Character Vacuum Fluorescent Display, Membrane Type User Control Push-buttons and easy to read LED Indicators Single handle Isolating Disconnect Switch/Circuit Breaker mechanism POWER ON LED PUMP RUN LED PHASE FAILURE LED PHASE REVERSAL LED LOW PRESSURE LED DELUGE OPEN LED INTERLOCK ON LED TRANSFER SWITCH NORMAL LED (If unit ordered with Automatic Power Transfer Switch) TRANSFER SWITCH EMERGENCY LED (If unit ordered with Automatic Power Transfer Switch) EMERGENCY ISOLATING SWITCH OFF LED (If unit ordered with Automatic Power Transfer Switch) Minimum Run Timer / Off Delay Timer Daylight Savings Time option Weekly Test Timer Motor Acceleration Timer Elapsed Time Meter Digital Pressure Display 1.44M Floppy Disk Drive Data Log Event Log (3000 Events) True RMS Metering with simultaneous 3 phase display of amps and volts Disk Error message Disk Near Full message Pressure Error message Motor Over 320% message Local Start message Remote Start message Emergency Start message Fail To Start message Undervoltage message Overvoltage message Low Suction Pressure message High Speed Open Serial Communications Port NEMA Type 2 enclosure

8 SPECIAL ENCLOSURES -T NEMA Type 3R (IEC IP14) -E NEMA Type 4 (IEC IP56) -F NEMA Type 4X (IEC IP56) FTA1000, 1250, 1300 FTA1350, 1500, 1800, G NEMA Type 12 (IEC IP52) CIRCUIT BREAKER OPTION -N Intermediate withstand rating 150,000 Amps RMS Sym. -P High withstand rating 200,000 Amps RMS Sym Note: Intermediate and High withstand ratings may not be available for all horsepowers and voltages. Consult factory for availability. ANTI-CONDENSATION SPACE HEATERS -H 120 Volt Space Heater -J 120 Volt Space Heater With Thermostat -K 120 Volt Space Heater With Humidistat -L 240 Volt Space Heater -M 240 Volt Space Heater With Thermostat -N 240 Volt Space Heater With Humidistat PRESSURE TRANSDUCERS -B psi ( bar) Pressure Transducer for Fresh Water Service -C psi ( bar) Pressure Transducer for Sea Water, Foam or Copper Corrosive Service -D psi ( bar) Pressure Transducer for Sea Water, Foam or Copper Corrosive Service AUTOMATIC POWER TRANSFER SWITCHES (Refer to publication SD900-21) FTA900 - generator set emergency supply FTA901 - bypass isolation switch for generator set emergency supply FTA950 - second utility emergency supply FTA951 - bypass isolation switch for second utility emergency supply ALARMS -AC Extra contacts (normally open & normally closed) for remote indication, pump operating -AF Audible and Visible low pump room temperature alarm -AG Built-in reservoir low alarm -AH Audible low suction pressure alarm -AM Contacts for remote indication, pump fail to start -AV Contacts for remote indication, low pump room temperature -AW Contacts for remote indication, reservoir low -AY Contacts for remote indication, low suction pressure -AZ Low pump room temperature switch, mounted and wired -BW Extra contacts for remote indication, phase failure/phase reversal -BY Contacts for remote indication, pump overload -COM Visible low suction pressure alarm with manual reset push-button -CTS Built in Low Suction Pressure Alarm Panel (Includes selectable auto/manual reset, audible, visible and remote alarms and mounted and wired pressure switch) -EG Visible relief valve discharge alarm -EH Contacts for remote indication, relief valve discharge -EJ Built-in flow meter on alarm -EK Contacts for remote indication, flow meter on -P Built-in alarm system (Includes visible supervisory voltage normal indication and audible pump operating, phase failure and phase reversal indication) -PB Built-in low system pressure visible alarm with manual reset -PE Contacts for remote indication, low system pressure -PT Built-in alarm system, 220 VAC supervisory power (Includes visible supervisory voltage normal indication and audible pump operating, phase failure and phase reversal indication) -HV Audible alarm device -LVA Visible pump on demand alarm -LW Audible and visible pump on demand alarm (requires (-HV)) -LY Contacts for remote indication, pump on demand (requires (-LVA) or (-LW)) MISCELLANEOUS -DZ Test push-button with solenoid valve* -ED Load shed circuits -EL Series pumping, high zone controller -EM Series pumping, mid zone controller(s) -EN Series pumping, low zone controller -PY Motor space heater output contacts -S Tropicalization -ZPA Customized, annual service display message (when factory programmed or programmed by Firetrol representative during start-up) -ZPB High Quality Impact Printer with paper take-up mechanism Export packaging FTA1000, 1250, 1300 FTA1350, 1500, 1800, 1900 *Weekly Test Timer Standard PD (B)

9 Product Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500 Description Firetrol FTA1500 Primary Resistance Fire Pump Controllers use resistors in the line to reduce line voltage when starting the pump motor. The controller monitors, displays and records fire pump system information. The circuit to the motor is not opened during the transition from start to run. While starting, the motor will draw 50% of full load starting current and supply 25% of rated torque. This method of starting minimizes line disturbances and voltage drop when starting. Approvals Firetrol fire pump controllers are listed by Underwriters' Laboratories, Inc., in accordance with UL218, Standard for Fire Pump Controllers, CSA, Standard for Industrial Control Equipment, and approved by Factory Mutual. They are built to meet or exceed the requirements of the approving authorities as well as NEMA and the latest editions of NFPA 20, Installation of Centrifugal Fire Pumps, and NFPA 70, National Electrical Code. Standard Features The following are included as standard with each controller: Voltage surge protector Main Disconnect Switch sized for connected motor horsepower and voltage Fire pump Circuit Breaker Motor contactor Emergency Manual Run Mechanism to mechanically close motor contactor contacts in an emergency condition Built-in Start and Stop push-buttons to bypass automatic start circuits Door mounted display/interface panel featuring a 40 Character Vacuum Fluorescent Display, Membrane Type User Control Push-buttons and easy to read LED Indicators Single handle Isolating Disconnect Switch/Circuit Breaker mechanism Transition Contactor and Power Resistors POWER ON LED PUMP RUN LED PHASE FAILURE LED PHASE REVERSAL LED LOW PRESSURE LED DELUGE OPEN LED INTERLOCK ON LED TRANSFER SWITCH NORMAL LED (If unit ordered with Automatic Power Transfer Switch) TRANSFER SWITCH EMERGENCY LED (If unit ordered with Automatic Power Transfer Switch) EMERGENCY ISOLATING SWITCH OFF LED (If unit ordered with Automatic Power Transfer Switch) Minimum Run Timer / Off Delay Timer Daylight Savings Time option Weekly Test Timer Motor Acceleration Timer Elapsed Time Meter Digital Pressure Display 1.44M Floppy Disk Drive Data Log Event Log (3000 Events) True RMS Metering with simultaneous 3 phase display of amps and volts Disk Error message Disk Near Full message Pressure Error message Motor Over 320% message Local Start message Remote Start message Emergency Start message Fail To Start message Undervoltage message Overvoltage message Low Suction Pressure message High Speed Open Serial Communications Port NEMA Type 2 enclosure

10 SPECIAL ENCLOSURES -T NEMA Type 3R (IEC IP14) -E NEMA Type 4 (IEC IP56) -F NEMA Type 4X (IEC IP56) FTA1000, 1250, 1300 FTA1350, 1500, 1800, G NEMA Type 12 (IEC IP52) CIRCUIT BREAKER OPTION -N Intermediate withstand rating 150,000 Amps RMS Sym. -P High withstand rating 200,000 Amps RMS Sym Note: Intermediate and High withstand ratings may not be available for all horsepowers and voltages. Consult factory for availability. ANTI-CONDENSATION SPACE HEATERS -H 120 Volt Space Heater -J 120 Volt Space Heater With Thermostat -K 120 Volt Space Heater With Humidistat -L 240 Volt Space Heater -M 240 Volt Space Heater With Thermostat -N 240 Volt Space Heater With Humidistat PRESSURE TRANSDUCERS -B psi ( bar) Pressure Transducer for Fresh Water Service -C psi ( bar) Pressure Transducer for Sea Water, Foam or Copper Corrosive Service -D psi ( bar) Pressure Transducer for Sea Water, Foam or Copper Corrosive Service AUTOMATIC POWER TRANSFER SWITCHES (Refer to publication SD900-21) FTA900 - generator set emergency supply FTA901 - bypass isolation switch for generator set emergency supply FTA950 - second utility emergency supply FTA951 - bypass isolation switch for second utility emergency supply ALARMS -AC Extra contacts (normally open & normally closed) for remote indication, pump operating -AF Audible and Visible low pump room temperature alarm -AG Built-in reservoir low alarm -AH Audible low suction pressure alarm -AM Contacts for remote indication, pump fail to start -AV Contacts for remote indication, low pump room temperature -AW Contacts for remote indication, reservoir low -AY Contacts for remote indication, low suction pressure -AZ Low pump room temperature switch, mounted and wired -BW Extra contacts for remote indication, phase failure/phase reversal -BY Contacts for remote indication, pump overload -COM Visible low suction pressure alarm with manual reset push-button -CTS Built in Low Suction Pressure Alarm Panel (Includes selectable auto/manual reset, audible, visible and remote alarms and mounted and wired pressure switch) -EG Visible relief valve discharge alarm -EH Contacts for remote indication, relief valve discharge -EJ Built-in flow meter on alarm -EK Contacts for remote indication, flow meter on -P Built-in alarm system (Includes visible supervisory voltage normal indication and audible pump operating, phase failure and phase reversal indication) -PB Built-in low system pressure visible alarm with manual reset -PE Contacts for remote indication, low system pressure -PT Built-in alarm system, 220 VAC supervisory power (Includes visible supervisory voltage normal indication and audible pump operating, phase failure and phase reversal indication) -HV Audible alarm device -LVA Visible pump on demand alarm -LW Audible and visible pump on demand alarm (requires (-HV)) -LY Contacts for remote indication, pump on demand (requires (-LVA) or (-LW)) MISCELLANEOUS -DZ Test push-button with solenoid valve* -ED Load shed circuits -EL Series pumping, high zone controller -EM Series pumping, mid zone controller(s) -EN Series pumping, low zone controller -PY Motor space heater output contacts -S Tropicalization -ZPA Customized, annual service display message (when factory programmed or programmed by Firetrol representative during start-up) -ZPB High Quality Impact Printer with paper take-up mechanism Export packaging FTA1000, 1250, 1300 FTA1350, 1500, 1800, 1900 *Weekly Test Timer Standard PD (C)

11 Product Description Autotransformer Starting Electric Fire Pump Controllers FTA1800 Description Firetrol FTA1800 Autotransformer Starting Fire Pump Controllers use an autotransformer to supply reduced voltage when starting the motor. The controller is of the closed circuit type where the motor circuit remains closed during the transition from start to run resulting in minimum line disturbance. The controller monitors, displays and records fire pump system information. The autotransformer has three taps for selection of starting current and torque; 50% tap for 150% current and 25% torque, 65% tap (factory setting) for 250% current and 42% torque and the 80% tap for 384% current and 64% torque. Approvals Firetrol fire pump controllers are listed by Underwriters' Laboratories, Inc., in accordance with UL218, Standard for Fire Pump Controllers, CSA, Standard for Industrial Control Equipment, and approved by Factory Mutual. They are built to meet or exceed the requirements of the approving authorities as well as NEMA and the latest editions of NFPA 20, Installation of Centrifugal Fire Pumps, and NFPA 70, National Electrical Code. Standard Features The following are included as standard with each controller: Voltage surge protector Main Disconnect Switch sized for connected motor horsepower and voltage Fire pump Circuit Breaker Motor contactor Emergency Manual Run Mechanism to mechanically close motor contactor contacts in an emergency condition Built-in Start and Stop push-buttons to bypass automatic start circuits Door mounted display/interface panel featuring a 40 Character Vacuum Fluorescent Display, Membrane Type User Control Push-buttons and easy to read LED Indicators Single handle Isolating Disconnect Switch/Circuit Breaker mechanism Transition Contactor and Autotransformer POWER ON LED PUMP RUN LED PHASE FAILURE LED PHASE REVERSAL LED LOW PRESSURE LED DELUGE OPEN LED INTERLOCK ON LED TRANSFER SWITCH NORMAL LED (If unit ordered with Automatic Power Transfer Switch) TRANSFER SWITCH EMERGENCY LED (If unit ordered with Automatic Power Transfer Switch) EMERGENCY ISOLATING SWITCH OFF LED (If unit ordered with Automatic Power Transfer Switch) Minimum Run Timer / Off Delay Timer Daylight Savings Time option Weekly Test Timer Motor Acceleration Timer Elapsed Time Meter Digital Pressure Display 1.44M Floppy Disk Drive Data Log Event Log (3000 Events) True RMS Metering with simultaneous 3 phase display of amps and volts Disk Error message Disk Near Full message Pressure Error message Motor Over 320% message Local Start message Remote Start message Emergency Start message Fail To Start message Undervoltage message Overvoltage message Low Suction Pressure message High Speed Open Serial Communications Port NEMA Type 2 enclosure

12 SPECIAL ENCLOSURES -T NEMA Type 3R (IEC IP14) -E NEMA Type 4 (IEC IP56) -F NEMA Type 4X (IEC IP56) FTA1000, 1250, 1300 FTA1350, 1500, 1800, G NEMA Type 12 (IEC IP52) CIRCUIT BREAKER OPTION -N Intermediate withstand rating 150,000 Amps RMS Sym. -P High withstand rating 200,000 Amps RMS Sym Note: Intermediate and High withstand ratings may not be available for all horsepowers and voltages. Consult factory for availability. ANTI-CONDENSATION SPACE HEATERS -H 120 Volt Space Heater -J 120 Volt Space Heater With Thermostat -K 120 Volt Space Heater With Humidistat -L 240 Volt Space Heater -M 240 Volt Space Heater With Thermostat -N 240 Volt Space Heater With Humidistat PRESSURE TRANSDUCERS -B psi ( bar) Pressure Transducer for Fresh Water Service -C psi ( bar) Pressure Transducer for Sea Water, Foam or Copper Corrosive Service -D psi ( bar) Pressure Transducer for Sea Water, Foam or Copper Corrosive Service AUTOMATIC POWER TRANSFER SWITCHES (Refer to publication SD900-21) FTA900 - generator set emergency supply FTA901 - bypass isolation switch for generator set emergency supply FTA950 - second utility emergency supply FTA951 - bypass isolation switch for second utility emergency supply ALARMS -AC Extra contacts (normally open & normally closed) for remote indication, pump operating -AF Audible and Visible low pump room temperature alarm -AG Built-in reservoir low alarm -AH Audible low suction pressure alarm -AM Contacts for remote indication, pump fail to start -AV Contacts for remote indication, low pump room temperature -AW Contacts for remote indication, reservoir low -AY Contacts for remote indication, low suction pressure -AZ Low pump room temperature switch, mounted and wired -BW Extra contacts for remote indication, phase failure/phase reversal -BY Contacts for remote indication, pump overload -COM Visible low suction pressure alarm with manual reset push-button -CTS Built in Low Suction Pressure Alarm Panel (Includes selectable auto/manual reset, audible, visible and remote alarms and mounted and wired pressure switch) -EG Visible relief valve discharge alarm -EH Contacts for remote indication, relief valve discharge -EJ Built-in flow meter on alarm -EK Contacts for remote indication, flow meter on -P Built-in alarm system (Includes visible supervisory voltage normal indication and audible pump operating, phase failure and phase reversal indication) -PB Built-in low system pressure visible alarm with manual reset -PE Contacts for remote indication, low system pressure -PT Built-in alarm system, 220 VAC supervisory power (Includes visible supervisory voltage normal indication and audible pump operating, phase failure and phase reversal indication) -HV Audible alarm device -LVA Visible pump on demand alarm -LW Audible and visible pump on demand alarm (requires (-HV)) -LY Contacts for remote indication, pump on demand (requires (-LVA) or (-LW)) MISCELLANEOUS -DZ Test push-button with solenoid valve* -ED Load shed circuits -EL Series pumping, high zone controller -EM Series pumping, mid zone controller(s) -EN Series pumping, low zone controller -PY Motor space heater output contacts -S Tropicalization -ZPA Customized, annual service display message (when factory programmed or programmed by Firetrol representative during start-up) -ZPB High Quality Impact Printer with paper take-up mechanism Export packaging FTA1000, 1250, 1300 FTA1350, 1500, 1800, 1900 *Weekly Test Timer Standard PD (C)

13 Product Description Solid State Starting Electric Fire Pump Controllers FTA1900 Description Firetrol FTA1900 Solid State Starting Fire Pump Controllers feature soft start, soft stop and system sensing capabilities that not only provide for reduced voltage starting, but also offer an improved level of hydromechanical performance. The controller monitors, displays and records fire pump system information. When called to run, the motor will accelerate along a ramp beginning at 40% of normal starting current with 15% of full voltage torque. When stopping, the motor will ramp down to a preset level and allow for a restart, limiting stress in the piping system. If no additional starting causes are present, the motor will continue to ramp down to a full stop. This controller helps to reduce water hammer in the system. Approvals Firetrol fire pump controllers are listed by Underwriters' Laboratories, Inc., in accordance with UL218, Standard for Fire Pump Controllers, CSA, Standard for Industrial Control Equipment, and approved by Factory Mutual. They are built to meet or exceed the requirements of the approving authorities as well as NEMA and the latest editions of NFPA 20, Installation of Centrifugal Fire Pumps, and NFPA 70, National Electrical Code. Standard Features The following are included as standard with each controller: Voltage surge protector Main Disconnect Switch sized for connected motor horsepower and voltage Fire pump Circuit Breaker Motor contactor Emergency Manual Run Mechanism to mechanically close motor contactor contacts in an emergency condition Built-in Start and Stop push-buttons to bypass automatic start circuits Door mounted display/interface panel featuring a 40 Character Vacuum Fluorescent Display, Membrane Type User Control Push-buttons and easy to read LED Indicators Single handle Isolating Disconnect Switch/Circuit Breaker mechanism Firetrol SS/3 Solid State SCR Starter POWER ON LED PUMP RUN LED PHASE FAILURE LED PHASE REVERSAL LED LOW PRESSURE LED DELUGE OPEN LED INTERLOCK ON LED TRANSFER SWITCH NORMAL LED (If unit ordered with Automatic Power Transfer Switch) TRANSFER SWITCH EMERGENCY LED (If unit ordered with Automatic Power Transfer Switch) EMERGENCY ISOLATING SWITCH OFF LED (If unit ordered with Automatic Power Transfer Switch) Minimum Run Timer / Off Delay Timer Soft Start Bypass Timer Daylight Savings Time option Weekly Test Timer Motor Acceleration Timer Elapsed Time Meter Digital Pressure Display 1.44M Floppy Disk Drive Data Log Event Log (3000 Events) True RMS Metering with simultaneous 3 phase display of amps and volts Disk Error message Disk Near Full message Pressure Error message Motor Over 320% message Local Start message Remote Start message Emergency Start message Fail To Start message Soft Starter Overtemp message Undervoltage message Overvoltage message Low Suction Pressure message High Speed Open Serial Communications Port NEMA Type 2 enclosure

14 SPECIAL ENCLOSURES -T NEMA Type 3R (IEC IP14) -E NEMA Type 4 (IEC IP56) -F NEMA Type 4X (IEC IP56) FTA1000, 1250, 1300 FTA1350, 1500, 1800, G NEMA Type 12 (IEC IP52) CIRCUIT BREAKER OPTION -N Intermediate withstand rating 150,000 Amps RMS Sym. -P High withstand rating 200,000 Amps RMS Sym Note: Intermediate and High withstand ratings may not be available for all horsepowers and voltages. Consult factory for availability. ANTI-CONDENSATION SPACE HEATERS -H 120 Volt Space Heater -J 120 Volt Space Heater With Thermostat -K 120 Volt Space Heater With Humidistat -L 240 Volt Space Heater -M 240 Volt Space Heater With Thermostat -N 240 Volt Space Heater With Humidistat PRESSURE TRANSDUCERS -B psi ( bar) Pressure Transducer for Fresh Water Service -C psi ( bar) Pressure Transducer for Sea Water, Foam or Copper Corrosive Service -D psi ( bar) Pressure Transducer for Sea Water, Foam or Copper Corrosive Service AUTOMATIC POWER TRANSFER SWITCHES (Refer to publication SD900-21) FTA900 - generator set emergency supply FTA901 - bypass isolation switch for generator set emergency supply FTA950 - second utility emergency supply FTA951 - bypass isolation switch for second utility emergency supply ALARMS -AC Extra contacts (normally open & normally closed) for remote indication, pump operating -AF Audible and Visible low pump room temperature alarm -AG Built-in reservoir low alarm -AH Audible low suction pressure alarm -AM Contacts for remote indication, pump fail to start -AV Contacts for remote indication, low pump room temperature -AW Contacts for remote indication, reservoir low -AY Contacts for remote indication, low suction pressure -AZ Low pump room temperature switch, mounted and wired -BW Extra contacts for remote indication, phase failure/phase reversal -BY Contacts for remote indication, pump overload -COM Visible low suction pressure alarm with manual reset push-button -CTS Built in Low Suction Pressure Alarm Panel (Includes selectable auto/manual reset, audible, visible and remote alarms and mounted and wired pressure switch) -EG Visible Relief Valve Discharge alarm -EH Contacts for remote indication, relief valve discharge -EJ Built-in flow meter on alarm -EK Contacts for remote indication, flow meter on -P Built-in alarm system (Includes visible supervisory voltage normal indication and audible pump operating, phase failure and phase reversal indication) -PB Built-in low system pressure visible alarm with manual reset -PE Contacts for remote indication, low system pressure -PT Built-in alarm system, 220 VAC supervisory power (Includes visible supervisory voltage normal indication and audible pump operating, phase failure and phase reversal indication) -HV Audible alarm device -LVA Visible pump on demand alarm -LW Audible and visible pump on demand alarm (requires (-HV)) -LY Contacts for remote indication, pump on demand (requires (-LVA) or (-LW)) MISCELLANEOUS -DZ Test push-button with solenoid valve* -ED Load shed circuits -EL Series pumping, high zone controller -EM Series pumping, mid zone controller(s) -EN Series pumping, low zone controller -PY Motor space heater output contacts -S Tropicalization -ZPA Customized, annual service display message (when factory programmed or programmed by Firetrol representative during start-up) -ZPB High Quality Impact Printer with paper take-up mechanism Export packaging FTA1000, 1250, 1300 FTA1350, 1500, 1800, 1900 *Weekly Test Timer Standard PD (B)

15 Product Description Power Transfer Switches for Electric Fire Pump Controllers FTA900 FTA950 Description Firetrol Power Transfer Switches are available completely assembled with Firetrol Electric Fire Pump Controllers; full or reduced voltage types. The power transfer switches are built in two versions: FTA900 For use when the normal power source is a utility and the emergency power source is a generator set. FTA950 For use when both the normal and emergency power sources are utilities. The entire package of power transfer switch and controller is completely factory assembled, wired, tested and shipped as a complete unit for easy field connection to the power sources and the fire pump motor. Approvals Firetrol power transfer switches are listed by Underwriters' Laboratories, Inc., in accordance with UL218, Standard for Fire Pump Controllers; UL1008, Automatic Transfer Switches; UL508, Industrial Control Equipment, CSA, Standard for Industrial Control Equipment; and approved by Factory Mutual. They are built to meet or exceed the requirements of the approving authorities as well as NEMA and the latest editions of NFPA 20, Installation of Centrifugal Fire Pumps, and NFPA 70, National Electrical Code. Standard Features The following are included as standard with each transfer switch: Emergency power source disconnect switch sized for connected motor horsepower and voltage (FTA950 only) Fire pump circuit breaker (FTA950 only) Mark II monitors for overcurrent tripping (non-thermal) of circuit breaker and alarm indicator for phase failure/phase reversal 3-pole, double throw transfer switch mechanism, electrically operated, mechanically held Control module providing for the following: Differential voltage sensing on all phases of the normal power source Voltage sensing of the emergency power source Frequency sensing of the emergency power source Transfer time delay to compensate for momentary power outages of the normal source Retransfer from emergency to normal source is automatically delayed unless the emergency source fails Cool-down timer for unloaded running of the generator set after retransfer to the normal power source Instantaneous retransfer to normal if the emergency source fails and the normal source is available 3 second transfer restart delay to reduce current surges when transferring to or from the emergency source NO and NC engine control contacts to start the generator set when the normal power source fails Transfer Switch Normal LED Transfer Switch Emergency LED Emergency Isolating Switch Open LED Test Selector Switch Transfer By-pass Switch Silence Alarm Pushbutton Emergency Isolating Switch Open and Transfer Switch in Emergency Audible Alarms Output contacts (NO and NC) for Generator Start, Emergency Isolating Switch Open and Transfer Switch position indicators Standard Withstand Rating, emergency side only FTA900 (Generator set equipped with molded case circuit breaker) A, 22,000A RMS Sym., V; 10,000A RMS Sym., V A, 35,000A RMS Sym., V; 10,000A RMS Sym., V A, 50,000A RMS Sym., V; 10,000A RMS Sym., V FTA950 See Options NEMA Type 2 enclosure (IEC IP11)

16 Note: The withstand rating of the normal power source side of the transfer switch will be the same as the withstand rating of the fire pump controller assembled with the power transfer switch. Options The following are available as options to FTA950 Power Transfer Switches: Circuit Breaker Option -M Standard withstand rating V - 100,000 Amps, RMS Sym. -N Intermediate withstand rating V - 150,000 Amps, RMS Sym. -P High withstand rating V - 200,000 Amps, RMS Sym. -Q Standard intermediate withstand rating V - 65,000 Amps RMS Sym. -R Standard low withstand rating V - 42,000 Amps RMS Sym. Modifications The following are available as modifications to all transfer switches: Special Enclosures -T NEMA Type 3R (IEC IP14) -E NEMA Type 4 (painted steel) (IEC IP56) -F NEMA Type 4X (#304 stainless steel) (IEC IP 56) -G NEMA Type 12 (IEC IP52) Special finish paint consult factory Special finish color consult factory Anti-condensation Space Heaters -H 120 Volt space heater -J 120 Volt space heater with thermostat -K 120 Volt space heater with humidistat -L 240 Volt space heater -M 240 Volt space heater with thermostat -N 240 Volt space heater with humidistat Alarms -EC Extra contacts for remote indication, transfer switch position -BX Contacts for remote indication, second utility source phase failure/phase reversal (FTA950 only) Miscellaneous -ED Load shed circuits -TM Microprocessor type (Group 5) control module -TN As above, with serial communications port -S Tropicalization PD900-20(A)

17 Product Description Limited Service Controllers FTA750 Description Firetrol FTA750 Limited Service Controllers may be used for the automatic control of small electrically driven fire pumps and booster pumps where they are acceptable to the authority having jurisdiction. Approvals Firetrol limited service controllers are listed by Underwriters' Laboratories, Inc., in accordance with UL218, Standard for Fire Pump Controllers, CSA, Standard for Industrial Control Equipment, and approved by Factory Mutual. They are built to meet or exceed the requirements of the approving authorities as well as NEMA and the latest editions of NFPA 20, Installation of Centrifugal Fire Pumps, and NFPA 70, National Electrical Code. Standard Features The following are included as standard with each controller: Voltage surge protector Main thermal-magnetic circuit breaker for assigned motor horsepower and voltage Firetrol FTA436 Phase Failure/Phase Reversal Monitor Motor contactor Power Available Pilot Light - indicates 3-phase power available and control power normal Phase Reversal Pilot Light - illuminates when phases are reversed Control transformer with 120 volt AC - secondary unfused for controller operating logic circuits, with fuse for possible external auxiliary devices Circuitry for start by remote deluge valve or other fire protection equipment (requires normally closed, open to start remote contacts) Remote interlock circuit (requires remote normally open contact which closes to operate) Built-in Start and Stop pushbuttons to bypass automatic start circuits Minimum Run Timer for automatic stop Pressure switch, integrally mounted on a threaded bulkhead fitting with external 1/2 inch connection Field connection remote alarm terminals (normally open-close to alarm and normally closed-open to alarm) for each of the following: Pump Operating, Pump Power Failure, Phase Reversal Emergency Manual Run Mechanism to mechanically close motor contactor contacts in an emergency condition operation of emergency run mechanism results in a full voltage start of the motor NEMA Type 2 enclosure (IEC IP11) Options The following are available as options to the controllers: Timer Option -A With running period timer (auto/manual start with auto/manual shutdown, selectable) -B Without running period timer (auto/manual start with manual shutdown only) Circuit Breaker Option -A Standard withstand rating 2-20 HP, V - 10,000 Amps, RMS Sym HP, V - 18,000 Amps, RMS Sym HP, V - 14,000 Amps, RMS Sym. -B Intermediate withstand rating V - 65,000 Amps, RMS Sym V - 18,000 Amps, RMS Sym. NOTE: Standard controllers contain MERCURY filled pressure switches which are readily and visibly labeled Contains Mercury - do not put in trash. Recycle or dispose as hazardous waste. Keep cover in place. To avoid the use of Mercury, contact Firetrol or your local representative for alternative devices.

18 Modifications The following are available as modifications to the controllers: Special Enclosures -T NEMA Type 3R (IEC IP14) -E NEMA Type 4 (painted steel) (IEC IP56) -F NEMA Type 4X (#304 stainless steel) (IEC IP56) -G NEMA Type 12 (IEC IP52) Special paint color or finish consult factory Anti-condensation Space Heaters -H 120 Volt space heater -J 120 Volt space heater with thermostat -K 120 Volt space heater with humidistat -L 240 Volt space heater -M 240 Volt space heater with thermostat -N 240 Volt space heater with humidistat Pressure Switches and Recorders -B psi ( kg/cm 2 ) pressure switch for fresh water service -C psi ( kg/cm 2 ) pressure switch for sea water/foam service -D psi ( kg/cm 2 ) pressure switch for sea water/foam service Automatic Power Transfer Switches (Refer to Publication PD975-01) FTA975 - generator set emergency supply FTA976 - second utility emergency supply Alarms -AC Extra contacts (normally open & normally closed) for remote indication, pump operating -AM Contacts for remote indication, pump fail to start -BW Extra contacts for remote indication, phase failure/phase reversal -BY Contacts for remote indication, pump overload -P Built-in alarm system (includes visible supervisory voltage normal indication and audible phase failure, phase reversal and pump run indication) -PB Built-in low system pressure visible alarm with manual reset -PE Contacts for remote indication, low system pressure Miscellaneous -A Sequential start -R Pump operating pilot light -S Tropicalization PD750-20(A)

19 Product Description Power Transfer Switches for Limited Service Controllers FTA975 FTA976 Description Firetrol Power Transfer Switches are available completely assembled with Firetrol Limited Service Controllers. The power transfer switches are built in two versions: FTA975 For use when the normal power source is a utility and the emergency power source is a generator set. FTA976 For use when both the normal and emergency power sources are utilities. The entire package of power transfer switch and controller is completely factory assembled, wired, tested and shipped as a complete unit for easy field connection to the power sources and the fire pump motor. Approvals Firetrol power transfer switches are listed by Underwriters' Laboratories, Inc., in accordance with UL218, Standard for Fire Pump Controllers; UL1008, Automatic Transfer Switches; UL508, Industrial Control Equipment, CSA, Standard for Industrial Control Equipment; and approved by Factory Mutual. They are built to meet or exceed the requirements of the approving authorities as well as NEMA and the latest editions of NFPA 20, Installation of Centrifugal Fire Pumps, and NFPA 70, National Electrical Code. Standard Features The following are included as standard with each transfer switch: Emergency power source disconnect switch sized for connected motor horsepower and voltage (FTA975 only) molded case isolating switch (FTA976 only) thermal-magnetic circuit breaker 3-pole, double throw transfer switch mechanism, electrically operated, mechanically held Control module providing for the following: Differential voltage sensing on all phases of the normal power source Voltage sensing of the emergency power source Frequency sensing of the emergency power source Transfer time delay to compensate for momentary power outages of the normal source Retransfer from emergency to normal source is automatically delayed unless the emergency source fails Cool-down timer for unloaded running of the generator set after retransfer to the normal power source Instantaneous retransfer to normal if the emergency source fails and the normal source is available 3 second transfer restart delay to reduce current surges when transferring to or from the emergency source NO and NC engine control contacts to start the generator set when the normal power source fails Transfer Switch Normal Pilot Light Transfer Switch Emergency Pilot Light Emergency Isolating Switch Open Pilot Light Test Selector Switch Transfer By-pass Switch Silence Alarm Pushbutton Emergency Isolating Switch Open and Transfer Switch in Emergency Audible Alarms Output contacts (NO and NC) for Generator Start, Emergency Isolating Switch Open and Transfer Switch position indicators Standard Withstand Rating, emergency side only FTA975 (Generator set equipped with molded case circuit breaker) 3-30HP, V, 10,000 Amps, RMS Sym. FTA HP, V, 10,000 Amps, RMS Sym HP, V, 18,000 Amps, RMS Sym. 3-30HP, V, 14,000 Amps, RMS Sym. NEMA Type 2 (IEC IP11) enclosure Note: The withstand rating of the normal power source side of the transfer switch will be the same as the withstand rating of the fire pump controller assembled with the power transfer switch.

20 Options The following are available as options to FTA976 Power Transfer Switches: Special Enclosures -T NEMA Type 3R (IEC IP14) -E NEMA Type 4 (IEC IP56) -F NEMA Type 4X (#304 Stainless Steel) (IEC IP56) -G NEMA Type 12 (IEC IP52) Special paint color or finish - Consult Factory Circuit Breaker Option -B Intermediate withstand rating V - 65,000 Amps, RMS Sym V - 18,000 Amps, RMS Sym. Modifications The following are available as modifications to all transfer switches: Anti-condensation Space Heaters -H 120 Volt space heater -J 120 Volt space heater with thermostat -K 120 Volt space heater with humidistat -L 240 Volt space heater -M 240 Volt space heater with thermostat -N 240 Volt space heater with humidistat Explanation of Catalog Number FTA975-BL100B-ED Type Modifications 975 Gen Set Voltage 976 Second Utility -H Start Option -A B Automatic -F Withstand rating -B A Standard (FTA976) -C B Intermediate (FTA976) Ampere rating -D Standard (FTA975) 100 Example FTA975-BD100B-ED FTA975 Power Transfer Switch for generator set emergency power source, 100 Amp, Volts, with load shed circuits. Note Due to continual product enhancements, dimensions and specifications may change at any time without notice. Contact the factory or local representative for current specifications. Alarms -BX Contacts for remote indication, second utility source phase failure/phase reversal (FTA976 only) Miscellaneous -ED Load shed circuits -TM Microprocessor type (Group 5) control module -TN As above, with serial communications port -S Tropicalization PD975-01(E)

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000 Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000 Description Firetrol FTA1000 Full Voltage Fire Pump Controllers are intended for use with electric motor driven fi re pumps

More information

Product Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500

Product Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500 Product Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500 Description Firetrol FTA1500 Primary Resistance Fire Pump Controllers use resistors in the line to reduce line voltage

More information

WITH POWER TRANSFER SWITCH STANDARD SUBMITTAL PACKAGE

WITH POWER TRANSFER SWITCH STANDARD SUBMITTAL PACKAGE WITH POWER TRANSFER SWITCH STANDARD SUBMITTAL PACKAGE SBP1930-61 FTA1930 Digital Solid State Starting Electric Fire Pump Controllers Product Description Fire Pump Controllers for Business-Critical Continuity

More information

Product Description Digital Solid State Starting Electric Fire Pump Controllers FTA1930

Product Description Digital Solid State Starting Electric Fire Pump Controllers FTA1930 Product Description Digital Solid State Starting Electric Fire Pump Controllers FTA1930 Description Firetrol FTA1930 Digital Solid State Starting Fire Pump Controllers feature soft start, soft stop and

More information

FTA1100-J DIESEL ENGINE FIRE PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE

FTA1100-J DIESEL ENGINE FIRE PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE FTA1100-J DIESEL ENGINE FIRE PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE SBP1100J FTA1100J Diesel Engine Fire Pump Controllers Product Description Description Firetrol combined automatic and manual Mark

More information

Limited Service Fire Pump Controllers Features

Limited Service Fire Pump Controllers Features Must Be Installed Per Applicable Code and Manufacturers Recommendations Limited Service Fire Pump Controllers Features 1-1 FD20 Full Voltage - Limited Service with Plus Microprocessor Power I/O Board Transformers

More information

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches PART 1 GENERAL 1.01 Scope Optional Standby Power Generator Systems A. Furnish and install automatic transfer switches

More information

FAIRBANKS NIJHUIS FIRE PUMPS. www.fairbanksnijhuis.com

FAIRBANKS NIJHUIS FIRE PUMPS. www.fairbanksnijhuis.com FAIRBANKS NIJHUIS FIRE PUMPS www.fairbanksnijhuis.com FAIRBANKS NIJHUIS Long established as a leading fire pump manufacturer, Fairbanks Nijhuis offers a broad range of horizontal and vertical split case,

More information

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original A motor starter is a combination of devices to allow an induction motor to start, run and stop according

More information

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw ,1'8675,$/#*(16(7 6HULHV#'9#448 32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw Generator set consisting of engine and alternator mounted

More information

MANUAL FOR MODEL MP30 ELECTRIC MOTOR DRIVEN LIMITED SERVICE CONTROLLER

MANUAL FOR MODEL MP30 ELECTRIC MOTOR DRIVEN LIMITED SERVICE CONTROLLER MANUAL FOR MODEL MP30 ELECTRIC MOTOR DRIVEN LIMITED SERVICE CONTROLLER Starting Serial No. "LA" This manual provides General Information, Installation, Operation, Maintenance and System Set-Up Information

More information

WYE-DELTA AND SOLID STATE STARTER APPLICATION GUIDE

WYE-DELTA AND SOLID STATE STARTER APPLICATION GUIDE WHITE PAPER WYE-DELTA AND SOLID STATE STARTER APPLICATION GUIDE EXPLANATION AND ASSISTANCE FOR APPLYING SOLID STATE SOFT STARTERS IN TRADITIONAL REDUCED VOLTAGE APPLICATIONS Introduction..............................................................2

More information

Transfer Equipment Controls

Transfer Equipment Controls Control Types Manual Transfer Switches Nonautomatic Transfer Switches Automatic Transfer Switches The type of control system for the transfer switch will vary depending on the type of switching equipment

More information

ASCO SERIES 185 Power Transfer Switches

ASCO SERIES 185 Power Transfer Switches ASCO SERIES 185 Power Transfer Switches 4-hour protection no matter when trouble strikes ASCO Series 185 Power Transfer Switches An Automatic Transfer Switch helps prevent... Your business or home from

More information

Operational Overview and Controls Guide. Two or Three Pump IronHeart Lite with Variable Frequency Drives

Operational Overview and Controls Guide. Two or Three Pump IronHeart Lite with Variable Frequency Drives DOCUMENT: ECSEQ6-0 EFFECTIVE: 09/23/10 SUPERSEDES: Operational Overview and Controls Guide Two or Three Pump IronHeart Lite with Variable Frequency Drives 6700 Best Friend Road. Norcross, GA 30071. (770)

More information

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options BT300 HVAC Drives Conventional Bypass (C-Bypass) Options Description The BT300 Conventional Bypass is a companion package for the family of BT300 HVAC Drives. For information on the family of BT300 HVAC

More information

MANUAL FOR MODEL MP300 to MP700 ELECTRIC MOTOR DRIVEN FIRE PUMP CONTROLLERS

MANUAL FOR MODEL MP300 to MP700 ELECTRIC MOTOR DRIVEN FIRE PUMP CONTROLLERS MANUAL FOR MODEL MP300 to MP700 ELECTRIC MOTOR DRIVEN FIRE PUMP CONTROLLERS Starting Serial No. "RA" This manual provides General Information, Installation, Operation, Maintenance and System Set-Up Information

More information

Limited Service Pump Controllers (Produced after July 18, 2006) Installation- Start Up - Service

Limited Service Pump Controllers (Produced after July 18, 2006) Installation- Start Up - Service Instruction Bulletin Limited Service Pump Controllers (Produced after July 18, 2006) Installation- Start Up - Service This instruction is a guide for personnel involved with Maintenance, Engineering and

More information

Fire Pump Controllers Remote Alarm Panels

Fire Pump Controllers Remote Alarm Panels Fire Pump Controllers Remote Alarm Panels Remote Alarm Panels 1.8 Remote Alarm Panels FDAP-M Electric... DFDAP-M Diesel... Product Specifications... 2 6 9 Features 1-1 DFDAP-M / FDAP-M Remote Alarm Panel

More information

Electric Motor Operator for: Gate Valves / Butterfly Valves / Plug Valves M&H VALVE

Electric Motor Operator for: Gate Valves / Butterfly Valves / Plug Valves M&H VALVE Electric Motor Operator for: Gate Valves / Butterfly Valves / Plug Valves M&H VALVE Almost every business day, M&H is assembling and testing valves with Electric Motor operators. Electric motor operator

More information

32VFD Variable Frequency Drives for Centrifugal Chillers

32VFD Variable Frequency Drives for Centrifugal Chillers 32VFD 32VFD Variable Frequency Drives for Centrifugal Chillers ENERGY-SAVING CONTROL FOR CENTRIFUGAL CHILLERS Reduce energy consumption in your existing centrifugal chiller Your chiller was specified to

More information

Horizontal Split Case Fire Pumpset Electric Motor Driven 50 Hz

Horizontal Split Case Fire Pumpset Electric Motor Driven 50 Hz SERIES Horizontal Split Case Fire Pumpset Electric Motor Driven 50 Hz Selected Models INTRODUCTION Lubi offers LHCE series state-of-the-art fire pumpset with electric motor driven, horizontal split case

More information

CENTERLINE Motor Control Centers Bulletin 2100 Smoke Detector Unit

CENTERLINE Motor Control Centers Bulletin 2100 Smoke Detector Unit Instructions CENTERLINE Motor Control Centers Bulletin 2100 Smoke Detector Unit Catalog Number 2100-SD1 Description The Bulletin 2100 smoke detector unit is a 0.5 space factor unit for use in Bulletin

More information

SECTION 26 29 23 VARIABLE FREQUENCY DRIVES

SECTION 26 29 23 VARIABLE FREQUENCY DRIVES SECTION 26 29 23 VARIABLE FREQUENCY DRIVES PART 1 GENERAL 1.01 SCOPE A. Furnish and install individual freestanding variable frequency AC drives (VFD) as shown on the Drawings and specified herein. 1.02

More information

AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL

AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL ATS-220 AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL For Use in 208 to 240 Volts Single and 3 Phase ATS Systems With 110Volt AC or DC Control Motors and selenoids 4501 NW 27 ave Miami FL 33142

More information

Chapter 5. Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams

Chapter 5. Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams Chapter 5 Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams Objectives Upon completion of this course, you will be able to: Explain what electrical loads are and their general purpose

More information

Operational Overview and Controls Guide

Operational Overview and Controls Guide DOCUMENT: ECSEQ2-1 EFFECTIVE: 02/14/07 SUPERSEDES: 02/26/03 Operational Overview and Controls Guide Standard Two or Three Pump Type VFD Booster Controls 6700 Best Friend Road. Norcross, GA 30071. (770)

More information

3) What is the difference between "Insulating", "Isolating", and "Shielded Winding" transformers?

3) What is the difference between Insulating, Isolating, and Shielded Winding transformers? Tyco Electronics Corporation Crompton Instruments 1610 Cobb International Parkway, Unit #4 Kennesaw, GA 30152 Tel. 770-425-8903 Fax. 770-423-7194 1) What is a transformer and how does it work? A transformer

More information

Oil and Coolant Circulating Heating System. Model - OCSM

Oil and Coolant Circulating Heating System. Model - OCSM Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine

More information

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS Features: INSTALLATION Install in accordance with NFPA 70. DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS Up to 1.95 Amps Load Capacity Class 2 Rated Outputs Overload, Over Voltage, and Short

More information

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars Presented By: Greg Pelster & Robert Schmid FFI Ferrie, Franzmann Industries LOW VOLTAGE SWITCHGEAR & LOW VOLTAGE

More information

Medium Voltage Motor Control Assemblies

Medium Voltage Motor Control Assemblies Medium Voltage Motor Control Assemblies Arc Resistant AMPGARD.1 Product............................................. 2 Application........................................... 2 Features, Benefits and Functions...................................

More information

..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark...

..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark... ..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark... TIME MARK CORPORATION 11440 EAST PINE STREET TULSA, OK 74116 USA tel 918 438-1220 fax 918 437-7584 www.time-mark.com

More information

Vilter motor starter solutions The NEW industry standard in motor starter packages

Vilter motor starter solutions The NEW industry standard in motor starter packages Vilter motor starter solutions The NEW industry standard in motor starter packages Electrical safety by design Built to Underwriters Laboratory (UL) 508A UL Standard for Safety for Industrial Control Panels.

More information

ETZGAR CONVEYOR COMPANY Controls Section v12.05

ETZGAR CONVEYOR COMPANY Controls Section v12.05 Section 7 Controls Page Description 7-1 Controls Index 7-2 Motor Data, Enclosure Rating and Abbreviations 7-3 Controls Safety Guidelines 7-4 Fixed Speed Controls Packages 7-5 Three Phase AC Variable Speed

More information

Bulletin 150 SMC Flex Smart Motor Controller Specifications

Bulletin 150 SMC Flex Smart Motor Controller Specifications Specifications Specifications Standard Features Optional Features Installation Setup Communications Power Wiring Control Wiring Keypad Software Starting and Stopping Modes Protection and Diagnostics Metering

More information

Guidelines on the Short Circuit Current Rating for Industrial Control Panels

Guidelines on the Short Circuit Current Rating for Industrial Control Panels usa.siemens.com/sccr Guidelines on the Short Circuit Current Rating for Industrial Control Panels Technical Paper for Practical Applications White Paper I October 2014 As per NEC Edition 2014, and UL508A

More information

26 3213.13 Diesel Engine Driven Generators Page 1 of 6

26 3213.13 Diesel Engine Driven Generators Page 1 of 6 Last Update: December 8, 2014 A. Description of System Consultant s Handbook Page 1 of 6 1. Provide a diesel engine driven electric generating unit, factory assembled, tested and certified to operate at

More information

Horizontal Split Case Fire Pumpset Diesel Engine Driven

Horizontal Split Case Fire Pumpset Diesel Engine Driven SERIES Horizontal Split Case Fire Pumpset Diesel Engine Driven Selected Models INTRODUCTION Lubi offers LHCD series state-of-the-art fire pumpset with diesel engine driven, horizontal split case pump.

More information

GTEC transfer switch open transition

GTEC transfer switch open transition GTEC transfer switch open transition 40-1250 Amp Description The GTEC automatic transfer switch combines reliability and flexibility in a small, economical package for transferring loads between a utility

More information

CONSTRUCTION STANDARDS DIVISION 23 HEATING VENTILATING AND AIR CONDITIONING

CONSTRUCTION STANDARDS DIVISION 23 HEATING VENTILATING AND AIR CONDITIONING PART 1-GENERAL 1.01 DESCRIPTION A. This specification is to cover a complete Variable Frequency motor Drive (VFD) consisting of a pulse width modulated (PWM) inverter designed for use on a standard NEMA

More information

Medical Air Systems: Scroll

Medical Air Systems: Scroll GENERAL The Chemetron skid mount scroll medical air system is designed to provide medical breathing air for hospital and medical institutions. This system meets NFPA 99 requirements for Level 1 breathing

More information

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH Cat transfer switches are designed for a variety of standby power applications. They provide flexibility, reliability and value in a

More information

Application Engineering

Application Engineering Application Engineering February 2011 Electronic Unit Controller Table of Contents 1. Introduction and Features... 2 1.1 Technical Specifi cations... 3 1.2 Pressure Probe Error Bypass... 3 1.3 Bump Start...

More information

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller Overview/Modes of Operation Bulletin 150 Smart Motor Controller The SMC-3 is a compact, simple to use, solid-state motor controller designed to operate 3-phase motors. It features a built-in overload relay

More information

How To Operate A Gec Transfer Switch Open Transition 40 2000 Amp Power Supply

How To Operate A Gec Transfer Switch Open Transition 40 2000 Amp Power Supply GTEC Transfer switch open transition 40 2000 amp Description GTEC transfer switches combine reliability and flexibility in a small, economical package for transferring loads between a utility and a generator

More information

*.ppt 11/2/2009 12:48 PM 1

*.ppt 11/2/2009 12:48 PM 1 Digital Compressor Controller *.ppt 11/2/2009 12:48 PM 1 Copeland Scroll Digital Controller Simple Controller That Enables OEM s To Use Digital Scrolls Relieves OEM From Developing Special Controllers

More information

How To Test A Power Switch On A Power Supply

How To Test A Power Switch On A Power Supply transfer switches Soft load Innovative, reliable, integrated solution Built with years of experience Powered with innovation Delivered with reliability A history of experience, innovation and reliability

More information

Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1

Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1 How to configure Part Numbers: Step : Select Switch Amperage Power Module Switch Rating (Amps) Power Module Switch Catalog No. 30 3 60 6 00 200 2 400 4 Step 2: Select Options Needed 5 Bussmann Power Module

More information

Cam switches. Page. Overview 4-2. ON-OFF switches, main switches, maintenance switches 4-3. Changeover switches, reversing switches 4-5

Cam switches. Page. Overview 4-2. ON-OFF switches, main switches, maintenance switches 4-3. Changeover switches, reversing switches 4-5 Eaton Wiring Manual / Page Overview - ON-OFF switches, main switches, maintenance switches - Changeover switches, reversing switches - (Reversing) star-delta switches - Multi-Speed Switches - Interlock

More information

SECTION 16720 - FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

SECTION 16720 - FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines PART 1 -- GENERAL 1.1 WORK OF THIS SECTION SECTION 16720 - City of San Diego, CWP Guidelines A. The WORK of this Section includes providing manual and automatic fire alarm and smoke detection systems meeting

More information

Low Voltage Fuses For Motor Protection

Low Voltage Fuses For Motor Protection Code Requirements The NEC or CEC requires that motor branch circuits be protected against overloads and short circuits. Overload protection may be provided by fuses, overload relays or motor thermal protectors.

More information

World Class Manufacturer of Fire Pump Controllers. Diesel

World Class Manufacturer of Fire Pump Controllers. Diesel World Class Manufacturer of Fire Pump Controllers Diesel World Class Quality When there s a call to start a fire pump in an emergency situation, you need a fire pump controller that you can count on to

More information

Rotary Phase Converters

Rotary Phase Converters FACTS from Ronk Electrical Industries, Inc. Bulletin 11981 Rotary Phase Converters ROTOVERTER Pat. No. 3,670,238 ROTO-CON Pat. No. 4,158,225 What are the ROTO-CON and ROTOVERTER power converters? The ROTO-CON

More information

Catalog January. Heavy industrial power applications Motor contactors and starters

Catalog January. Heavy industrial power applications Motor contactors and starters Catalog January Heavy industrial power applications Motor contactors and starters 2006 General contents 0 Heavy Industrial Power Applications Motor Contactors and Starters 1 Contactors and Starters, Type

More information

SECTION 13XXX CONTROL DESCRIPTION (DICP Models 02-412NC, 412, 622, 826, 1030)

SECTION 13XXX CONTROL DESCRIPTION (DICP Models 02-412NC, 412, 622, 826, 1030) PART 1 - GENERAL SECTION 13XXX CONTROL DESCRIPTION (DICP Models 02-412NC, 412, 622, 826, 1030) 1.01 SUMMARY This section describes the operation and control of a drip irrigation system. The major components

More information

SECTION 15750 PACKAGED ROOFTOP AIR CONDITIONING UNITS

SECTION 15750 PACKAGED ROOFTOP AIR CONDITIONING UNITS SECTION 15750 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for roof mounted, self-contained units, with electric cooling, and electric or reverse refrigeration cycle (heat pump) heating

More information

FLORIDA ATLANTIC UNIVERSITY FIRE ALARM SYSTEM INSTALLATION MANUAL

FLORIDA ATLANTIC UNIVERSITY FIRE ALARM SYSTEM INSTALLATION MANUAL FLORIDA ATLANTIC UNIVERSITY FIRE ALARM SYSTEM INSTALLATION MANUAL January, 2003 Environmental Health and Safety Florida Atlantic University 777 Glades Rd. Boca Raton, FL 33431 Phone: 561-297-3129 Fax:

More information

SMC FLEX QUICK START BULLETIN 150

SMC FLEX QUICK START BULLETIN 150 QUICK START SMC FLEX BULLETIN 0 This guide provides you with the basic information required to start up your SMC Flex controller. When reading this document, look for this symbol Step x to guide you through

More information

SECTION 13850 DETECTION AND ALARM

SECTION 13850 DETECTION AND ALARM SECTION 13850 DETECTION AND ALARM PART 1 GENERAL 1.01 SUMMARY A. Section Includes 1. Control Panel 2 Associated Equipment B. Products Installed But Not Supplied Under This Section 1. Section 16140 - Wiring

More information

LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA. General Specification

LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA. General Specification 08/17/12 Rev2 LTR Series General Specification 700 VA to 2.1 KVA 1.0 General LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA General Specification This specification describes the features and

More information

SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT PART 1 - GENERAL 1.1 DESCRIPTION A. The Work specified in this Section consists of designing, furnishing and installing factory-assembled

More information

TP-C2 Motor Operator CLEAVELAND / PRICE INC. Bulletin DB-111B12

TP-C2 Motor Operator CLEAVELAND / PRICE INC. Bulletin DB-111B12 Bulletin DB-111B12 TP-C2 Motor Operator CLEAVELAND / PRICE INC. 14000 Rt. 993, Trafford, PA 15085 (724) 864-4177 FAX (724) 864-9040 Email: sales@cleavelandprice.com Cleaveland/Price Type TP-C2 Motor Operator

More information

Unified requirements for systems with voltages above 1 kv up to 15 kv

Unified requirements for systems with voltages above 1 kv up to 15 kv (1991) (Rev.1 May 2001) (Rev.2 July 2003) (Rev.3 Feb 2015) Unified requirements for systems with voltages above 1 kv up to 15 kv 1. General 1.1 Field of application The following requirements apply to

More information

Sentron Series Circuit Breakers

Sentron Series Circuit Breakers Sentron Series Circuit Breakers Siemens Sentron Series circuit breakers are available in nine frame sizes: ED, FD, JD, LD, LMD, MD, ND, PD, and RD. Sentron Series circuit breakers have a wide range of

More information

The HVAC SOLUTION DELIVERING POWER...SAVING ENERGY

The HVAC SOLUTION DELIVERING POWER...SAVING ENERGY The HVAC SOLUTION DELIVERING POWER...SAVING ENERGY PowerGate - Cost effective solutions for F 1 Horsepower Rating 001 1-40 HP (208V) 075 1-75 HP (480V) Input Voltage 2V 208-240V 4V 380-480V Disconnect

More information

BERMAD Fire Protection

BERMAD Fire Protection 400E-2M/700E-2M IOM Bermad Electrically Controlled Deluge Valve with EasyLock Manual Reset Model: 400E-2M/700E-2M INSTALLATION OPERATION MAINTENANCE Application Engineering BERMAD 400E-2M/700E-2M Bermad

More information

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A AUTOMATIC TRANSFER SWITCH Changeover Type from 250A to 2500A Table of Contents Preamble 1.1 Theoretical base 1.2 Selection the size of automatic transfer switch 1.3 Automatic transfer switch components

More information

Electrical Systems - IQAN Digital Control System. IQAN Control System Components... 5.1.3

Electrical Systems - IQAN Digital Control System. IQAN Control System Components... 5.1.3 Section 5.1 Electrical Systems - IQAN Digital Control System IQAN Control System Components........................... 5.1.3 IQAN Operational Description: At Machine Startup.....................................

More information

PowerCommand Paralleling System Digital MasterControl

PowerCommand Paralleling System Digital MasterControl PowerCommand Paralleling System Digital MasterControl Description The PowerCommand Digital MasterControl is a systemlevel controller designed to interface directly with Cummins Power Generation PowerCommand

More information

ANCILLARY EQUIPMENT AND ELECTRICAL EQUIPMENT Power Supply Systems and Electrical Equipment for Desalination Plants - Y.M. Hamud and A.H.

ANCILLARY EQUIPMENT AND ELECTRICAL EQUIPMENT Power Supply Systems and Electrical Equipment for Desalination Plants - Y.M. Hamud and A.H. POWER SUPPLY SYSTEMS AND ELECTRICAL EQUIPMENT FOR DESALINATION PLANTS Y.M. Hamud and A.H. Anwar Abu Dhabi Water and Electricity Authority, Abu Dhabi, UAE Keywords : Electrical System, Network for Desalination,

More information

EATON Diesel Plus Diesel Engine Fire Pump Controller

EATON Diesel Plus Diesel Engine Fire Pump Controller O & M Manual IM05805019K-002 Effective April 2015 EATON Diesel Plus Diesel Engine Fire Pump Controller Powering Business Worldwide O & M Manual IM05805019K-002 Effective April 2015 EATON Diesel Plus Diesel

More information

Suitable for Emergency, Peak and Prime Power System Applications. Low Voltage Automatic Transfer Switch Systems

Suitable for Emergency, Peak and Prime Power System Applications. Low Voltage Automatic Transfer Switch Systems Suitable for Emergency, Peak and Prime Power System Applications Low Voltage Automatic Transfer Switch Systems THE POWER AUTHORITY THE POWER AUTHORITY ASCO s experience and commitment to excellence in

More information

Specification Requirements DBL 700MX and 1000MX Series UPS

Specification Requirements DBL 700MX and 1000MX Series UPS Specification Requirements DBL 700MX and 1000MX Series UPS Theory of Operation Upon loss of utility power, the UPS inverter shall continue to provide seamless pure sine-wave AC from the batteries without

More information

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

Submit shop drawings for equipment provided under this section Shop drawings shall indicate: Section 16435 - SWITCHBOARDS Introduction Part 1 - General Reference The work under this section is subject to requirements of the Contract Documents including the General Conditions, Supplementary Conditions,

More information

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P) Low Water Cut-Off/Pump Controllers For Steam Boilers and Other Level Control Applications McDonnell & Miller Installation & Maintenance Instructions

More information

Continuous Power... Continuous Protection

Continuous Power... Continuous Protection Series 165 We Keep Your Power On Continuous Power... Continuous Protection An Automatic Transfer Switch helps prevent... Your business or home from losing power during bad weather or utility power equipment

More information

Contactor and Starter Ratings

Contactor and Starter Ratings Contactor and Starter Ratings Contactors and motor starters are rated according to size and type of load they are designed to handle. The National Electrical Manufacturers Association (NEMA) and the International

More information

SmartPro 120V 500VA 300W Line-Interactive UPS, SNMP, Webcard, 1U Rack/Tower, USB, DB9 Serial

SmartPro 120V 500VA 300W Line-Interactive UPS, SNMP, Webcard, 1U Rack/Tower, USB, DB9 Serial SmartPro 120V 500VA 300W Line-Interactive UPS, SNMP, Webcard, 1U Rack/Tower, USB, DB9 Serial MODEL NUMBER: SMART500RT1U Description Tripp Lite's SMART500RT1U intelligent, line-interactive rack/tower uninterruptible

More information

SENTRA SERIES WATER UNITS. 30 to 300 F Process Temperatures. 1/2 to 7.5 HP Centrifugal Pumps (20-100 GPM) 10 to 34 KW Stainless Steel Heaters

SENTRA SERIES WATER UNITS. 30 to 300 F Process Temperatures. 1/2 to 7.5 HP Centrifugal Pumps (20-100 GPM) 10 to 34 KW Stainless Steel Heaters Temperature Control Units Water & Oil - 00 F Portable Chillers Air & Water-Cooled 0-70 F Central Chillers Air & Water-Cooled Packages & Modules 0-70 F Pump Tank Stations Chilled or Tower Water 00-00 gallons

More information

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2

More information

Centro-Matic Automatic Lubrication Systems System Controls

Centro-Matic Automatic Lubrication Systems System Controls Selecting the right controls for your automated lubrication system is one of the last steps in the design process. Several different models may be chosen to control power-operated pumps, depending on the

More information

AP/UP, AP/MIL Series. Magnetic Circuit Protectors

AP/UP, AP/MIL Series. Magnetic Circuit Protectors AP/UP, AP/MIL Series Magnetic Circuit Protectors Introduction Poles Configurations Operating Characteristics Delay Curves Specifications Decision Tables 71 72 75 76 77 78 79 AP/UP, AP/MIL Series Hydraulic

More information

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments Model #: SM2000RMX Heavy-duty, industrial-grade metal housings Shock and vibration rated to MIL-STD-810D 19 inch

More information

Single Phase Soft Starter

Single Phase Soft Starter Single Phase Soft Starter Installation & Operating Manual 6/02 Table of Contents Section 1 General Information................................................... 1 1 General Description................................................

More information

Fire Alarm System Plans Review Checklist Property location Date of Review

Fire Alarm System Plans Review Checklist Property location Date of Review Fire Alarm System Plans Review Checklist Property location Date of Review 1. Is application completed in entirety? 2. Are the plans review fee submitted with the application? 3. Does floor plan include

More information

Motor Protection Voltage Unbalance and Single-Phasing

Motor Protection Voltage Unbalance and Single-Phasing Motor Protection Voltage Unbalance and Single-Phasing Cooper Bussmann contributes the following information, which is an excerpt from their 190-page handbook SPD Selecting Protective Devices Based on the

More information

LMR Plus Electric Fire Pump Controllers Custom Messages

LMR Plus Electric Fire Pump Controllers Custom Messages Instructions on how to save for uploading to the LMR Plus controller. Up to ten (10) different messages can be uploaded to the LMR Plus controller and displayed on the bottom (fourth line) of the LCD display.

More information

HP 5 Microprocessor Control for Mammoth Water Source Heat Pumps

HP 5 Microprocessor Control for Mammoth Water Source Heat Pumps HP 5 Microprocessor Control for Mammoth Water Source Heat Pumps Operation and Maintenance Manual Model: 71028004 Applies to: Single Circuit Water-to-Water Twin Circuit Units Without DDC Controls MAMM WHSP

More information

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS UNIT OBJECTIVES After studying this unit, the reader should be able to Describe the different types of open single-phase motors used to drive

More information

MCC Ratings. Voltage Rating

MCC Ratings. Voltage Rating MCC Ratings In addition to the various ratings of individual components used in motor control centers, the overall ratings of the motor control center must also be considered. Voltage Rating Motor control

More information

Product Guide AC Voltage Control Devices. Guide Guide. Popular Variable Transformers and AC Power Supplies. www.stacoenergy.com

Product Guide AC Voltage Control Devices. Guide Guide. Popular Variable Transformers and AC Power Supplies. www.stacoenergy.com Popular Variable Transformers and AC Power Supplies Product Guide AC Voltage Control Devices Guide Guide Your Tailored Power Solutions Provider TM Staco Energy Products Co. has been a leading manufacturer

More information

Safety automation solutions

Safety automation solutions Operating principle, characteristics Preventa safety s types XPS AV,, For and switch monitoring Operating principle Safety s XPS AV, and are used for monitoring circuits conforming to standards EN/ISO

More information

ATC-300 Automatic Transfer Switch Controller

ATC-300 Automatic Transfer Switch Controller ATC-300 Technical Data New Information Technical Data Page 2 Effective: May 2004 ATC-300 Introduction The Cutler-Hammer ATC-300 from Eaton s Electrical business is a comprehensive, multi-function, microprocessor-based

More information

Understanding Emergency Power Off (EPO)

Understanding Emergency Power Off (EPO) Understanding Emergency Power Off (EPO) White Paper #22 Executive Summary Emergency Power Off (EPO) is the capability to power down a piece of electronic equipment or an entire installation from a single

More information

SECTION 16260 STATIC UNINTERRUPTIBLE POWER SUPPLY SYSTEM

SECTION 16260 STATIC UNINTERRUPTIBLE POWER SUPPLY SYSTEM 1 0 1 0 1 SECTION 0 PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Uninterruptible power supply (UPS) system. B. Related Sections include but are not necessarily limited to: 1. Owner s - Bidding

More information

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 3000VA, 5000VA and 6000 VA Smart-UPS RT 230VAC Uninterruptible Power Supply

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 3000VA, 5000VA and 6000 VA Smart-UPS RT 230VAC Uninterruptible Power Supply APC Smart-UPS RT GUIDE SPECIFICATIONS FOR 3000VA, 5000VA and 6000 VA Smart-UPS RT 230VAC Uninterruptible Power Supply PART 1 - GENERAL 1.1 SUMMARY A. This specification describes the operation and functionality

More information

543-0032-00, 943-0032-00. User s Manual

543-0032-00, 943-0032-00. User s Manual 543-0032-00, 943-0032-00 User s Manual 1 Comfort Alert Diagnostics Faster Service And Improved Accuracy The Comfort Alert diagnostics module is a breakthrough innovation for troubleshooting heat pump and

More information

SECTION 13XXX DISPERSAL PUMP STATION (4x4 DiPS)

SECTION 13XXX DISPERSAL PUMP STATION (4x4 DiPS) SECTION 13XXX DISPERSAL PUMP STATION (4x4 DiPS) PART 1: GENERAL 1.01 SCOPE OF WORK A. Under this section of the specifications, the contractor shall furnish and install a shop-fabricated 4X4 Dispersal

More information

2011 Industrial Catalog. DRIVES, PAC, PLCs. Industrial Catalog 2011. www.toshiba.com/ind

2011 Industrial Catalog. DRIVES, PAC, PLCs. Industrial Catalog 2011. www.toshiba.com/ind www.toshiba.com/ind 2011 Toshiba International Corporation Rev. 110504 Industrial Catalog 2011 13131 W. Little York Road Houston, TX 77041 Tel: 713-466-0277 Fax: 713-466-8773 US: 800-231-1412 Canada: 800-872-2792

More information