Technical report High-efficiency volume reduction of cord blood using pentastarch

Size: px
Start display at page:

Download "Technical report High-efficiency volume reduction of cord blood using pentastarch"

Transcription

1 (2001) 27, Nature Publishing Group All rights reserved /01 $ Technical report High-efficiency volume reduction of cord blood using pentastarch H Yang 1,2, JP Acker 3, D Abley 1, LE McGann 1,2,3 and J Akabutu 1,4 1 Alberta Cord Blood Bank, 2 Canadian Blood Services, Departments of 3 Laboratory Medicine and Pathology, 4 Pediatrics, University of Alberta, Edmonton, Alberta, Canada Summary: Human umbilical cord blood (UCB) has been used successfully to treat a variety of genetic, hematological, and oncologic disorders. However, the low number of hematopoietic progenitor cells available in donated cord blood samples limits transplantation of cord blood to children and small adults. Reduction of the volume of umbilical cord blood is widely used in cord blood banking to reduce the storage requirements in large-scale UCB banks. Unfortunately, during the volume reduction process, up to 40% or more of the progenitor cells are lost using current reduction methods. This study describes a highly reproducible, double collection technique using Pentaspan to reduce UCB volume by red cell depletion. This results in the preservation of critical hematopoietic progenitor cells. The final volume of the leukocyte concentrates (LC) was 19.8 ± 0.4 ml with 95% red cell depletion. The recovery of nucleated cells (NC), mononuclear cells (MNC), CD34 + cells and colony-forming units (CFU) following double collection was 89%, 94%, 96%, and 106%, respectively. This is significantly higher than the recovery from single collections, where recovery was 74%, 77%, 84%, and 91% for NC, MNC, CD34 + and CFU, respectively. The double collection technique provides an efficient and highly reproducible method for the preparation of UCB for long-term storage and transplantation. Bone Marrow Transplantation (2001) 27, Keywords: umbilical cord blood; flow cytometry; volume reduction; leukocytes; CD34 + Over the last decade, more than 1000 cases of successful human umbilical cord blood transplantation have been reported. This has established the utility of using umbilical cord blood as an alternative source of hematopoietic stem cells for bone marrow reconstitution. Hematopoietic progenitors from umbilical cord blood have many advantages over adult bone marrow and peripheral blood stem cells. 1 4 The main disadvantage of umbilical cord blood is the Correspondence: Dr H Yang, Alberta Cord Blood Bank, 3rd Floor Canadian Blood Services Building, Street, Edmonton, Alberta T6G 2R8, Canada Received 13 July 2000; accepted 30 October 2000 restricted volume of the donated cord blood sample. This limits the absolute number of hematopoietic progenitor cells available for transplantation. A low nucleated cell dose can significantly decrease recipient survival after hematopoietic progenitor cell transplantation. 5 Maximizing the number of hematopoietic progenitor cells available for transplantation is critical, and efforts have focused on improving the number of cells that are recovered during cord blood banking procedures. is widely used in cord blood banking to improve available storage space. 6,7 The current method for volume reduction was developed by Rubinstein et al 6 and is followed by most cord blood banks worldwide. The volume of cord blood is reduced by enhanced sedimentation of red cells by rouleaux formation that is induced by a strong sedimenting agent such as 6% hydroxyethyl starch (Hespan). However, the number of nucleated cells lost during this procedure can be 40% or more. 1,8,9 As a result of this cell loss, mainly children meet the optimal nucleated cell dose of /kg of recipient body weight that is used as a minimum requirement for a successful transplantation outcome. 10 In order to expand the pool of patients able to receive transplants, only donated cord blood samples that have a large initial volume are banked. Unfortunately, valuable cord blood samples that do not meet the minimum volume criteria or minimum recovery of leukocytes are routinely discarded. Without more efficient methods that reduce the volume of umbilical cord blood samples, use of cord blood as an alternative source of hematopoietic progenitor cells will remain limited to children and small adults. This study describes an efficient and reproducible method using Pentaspan to reduce the total volume of cord blood samples without significantly reducing the number of nucleated cells during the process. Materials and methods Cord blood collection Registered mothers, with informed consent, donated cord blood samples from normal full-term deliveries under a protocol reviewed by the Institution s Health Research Ethics Board. Cord blood was collected from the umbilical vein by gravity drainage into a blood collection bag containing 23 ml citrate phosphate dextrose adenine (CPDA-

2 458 1) anticoagulant (Medsep, Covina, CA, USA). The collected cord blood was stored at room temperature and processed within 36 h of collection. Volume reduction Single collection: Ten percent pentastarch (Pentaspan; DuPont, Mississauga, Ontario, Canada) was added to the cord blood in the collection bag to obtain a final concentration of 2% and was incubated at room temperature for 5 min. Centrifugation time was determined by the volume of cord blood with CPDA-1 using the following, empirically derived formula (unpublished): K CT = (1) L M where CT = centrifugation time, K = , L = ln (volume of cord blood with 23 ml CPDA), M = The bag was held vertically in a centrifuge bucket using styrofoam inserts and centrifuged at 52 g at 10 C for the time calculated from the above formula. After completion of the centrifugation, the buffy coat was expressed into a 150 ml transfer bag (No. 1 transfer bag; Baxter Healthcare, Deerfield, IL, USA) using a plasma extractor (Baxter Healthcare). The transfer bag was then centrifuged at 400 g for 10 min at 10 C. The plasma was expressed into a second transfer bag (No. 2 transfer bag) resulting in approximately 20 ml of leukocyte concentrate (LC) remaining in the first transfer bag. The leukocyte concentrate was then assessed. Double collection: The first collection of the double collection was the same as for the single collection except that plasma from No. 1 transfer bag was returned to the collection bag (containing depleted red blood cells and leukocytes). The closed processing system was reassembled by reconnecting the plastic tubing of No. 1 transfer bag and the collection bag using a sterile tubing welder (Terumo Medical, MD, USA). The tube on the collection bag was then sealed using a hand sealer (Sebra, Tucson, AZ, USA) at 10 cm from the bag and then cut. The collection bag was held vertically in a centrifuge bucket using styrofoam inserts, and centrifuged at 52 g at 10 C for the time calculated from Equation 1. When multiple samples were processed, the average centrifuge time as calculated from Equation 1 was used. After completion of the centrifugation, the collection bag was re-connected to No. 1 transfer bag (containing the initial leukocyte concentrate) using the sterile tube welder as before. The No. 1 transfer bag was then centrifuged at 400 g for 10 min at 10 C. After completion of the centrifugation, the plasma was expressed into a second transfer bag (No. 2 transfer bag) using a plasma extractor, leaving a final volume of 20 ml of leukocyte concentrate in the No. 1 transfer bag. Enumeration and viability of CD34 + cells CD34 + cells were quantified using the flow cytometric technique described by Keeney et al. 11 Briefly, nucleated cells from either cord blood, LC from first collection, or LC from double collection were treated with either 20 l CD34-PE (580 clone)/cd45-fitc (J33 clone) or CD45-FITC/Isoclonic PE at room temperature for 20 min in the dark. Two milliliters of 10% ammonium chloride was added to the tubes followed by 20 l 7-amino-actinomycin D (7-AAD, 1 g/ml; Molecular Probes, Eugene, OR, USA). The tubes were incubated for 15 min in the dark, and then 100 l of Coulter Stem-Count beads was added. Within one hour of sample preparation, flow cytometric analysis was performed on a Coulter EPICS XL/MCL cytometer (Coulter, Hialeah, FL, USA). The 7-AAD functions to determine cell viability. 7-AAD is an analog of actinomycin D that binds between cytosine and guanine bases of DNA. 12 The 7-AAD/DNA complex has a maximum absorption at 546 nm with a red fluorescent emission at 647 nm. These spectral characteristics result in 7-AAD being well suited for argon laser equipped cytometry that has an excitation wavelength of 488 nm. There is little spectral overlap between 7-AAD and FITC or PE, further enhancing its suitability for assessing CD34 + cells with single platform flow cytometry. Viability of nucleated cells The viability of nucleated cells was assessed in the 7-AAD stained samples, and analyzed using a flow cytometer. Hematological cell counts The number of total NC and MNC was determined using a Coulter A c.t diff analyzer (Beckman-Coulter, Miami, FL, USA). Any abnormal flags on the Coulter report were verified by manual count of 200 nucleated cells using Sure Stain, a Wright-Giemsa based stain (Fisher Scientific, Pittsburgh, PA, USA) following the manufacturer s instructions. Colony-forming assay (CFU) CFU in pre-processed (whole cord blood), LC from single collection and LC from double collection were assessed using a commercially prepared complete methylcellulose medium, Methocult GF H4434 (StemCell Technologies, Vancouver, BC, Canada). Cells were plated without further separation in triplicate at a concentration of cells per well. After incubation at 37 C for 14 days in humidified air containing 5% CO 2, granulocyte macrophage (CFU- GM), erythroid (BFU-E) and granulocyte erythroid macrophage megakaryocyte (CFU-GEMM) colonies were scored by microscopic examination. Bacteriology To check for contamination, 0.5 ml samples of pre-processed cord blood and LC collected after the double collection technique were tested for sterility. Bacterial and fungal contamination were evaluated using the Bactec method (Becton Dickinson, Mountain View, CA, USA). Statistics A statistical comparison between the recovery obtained using the single and double collection methods was perfor-

3 Volume reduction, red cell depletion, viability and contami- n Mean ± s.e.m. (range) Pre-processed Double collection Table 1 nation NC, MNC and CD34 + cells. The results also indicate that the range for all cell types is narrower when the double collection technique is used compared to the single collection technique. The recovery from the double collection was much more consistent. 459 Volume (ml) ± ± 0.4 ( ) ( ) RBC depletion (%) 22 NA 94.5 ± 0.7 ( ) Viability (%) Nucleated cells ± ± 0.29 ( ) ( ) CD34 + cells ± ± 0.5 (91 100) (91 100) Sterility test 22 Negative Negative NA = not applicable. med. A one-way ANOVA was used with a level of significance set at Results Volume reduction Table 1 shows that using the double collection technique reduces the volume of cord blood by three quarters from an original volume of 79 ± 5.1 ml to 19.8 ± 0.4 ml without a significant loss of viability of nucleated cells or CD34 + cells. The achieved red cell depletion was 94.5 ± 0.7%. Cell recovery Table 2 shows total cell counts of pre-processed samples, and samples processed by single collection or double collection method. More cells are recovered from the double collection than from the single collection method. In Table 2, percent recovery of NC, MNC, CD34 + cells and CFU following processing is shown. Double collection technique improved the average recovery of NC, MNC, CD34 + cells, and CFU by 15%, 18%, 12% and 15%, respectively. The increased recovery obtained using the double collection technique is statistically significant for Bacteriology As showed in Table 1, there was no bacterial or fungal contamination of either the pre-processed samples or the samples from the double collection process following a 7-day culture. Discussion This study describes a double collection method that can be used to significantly enhance the recovery of the LC from umbilical cord blood samples while providing excellent volume reduction. The single collection permits depletion of red cells, reduction of plasma volume and collection of LC. This single collection method is widely used in clinical cord blood banks. However, the recovery of NC and MNC is highly variable. The cord blood banking standard for recovery of NC and MNC has been proposed to be 60% and 80%, respectively. 8 In Table 2, recovery of NC after a single collection was 73.5% with a range of 46.6 to 100%. According to the proposed standard, two out of the 22 cord blood specimens in this study, or 9%, would have had to be discarded. However, when the double collection procedure was employed recovery was increased to 89.2% with a range of %. In this case, none of the samples would have had to have been discarded. It is shown in Table 1 that the recovery of NC, MNC, CD34 + cells and CFU from a double collection was significantly higher than from a single collection. More important is the fact that the cell recovery from the double collection method was highly consistent within a very narrow range. These data suggest that the proposed cord blood banking standard requiring cord blood samples to be discarded after unsuccessful volume reduction 8 is not necessary if a double collection process is employed especially for large-volume cord blood samples. The process is appropriately named double collection as Table 2 Total cell count and yield of cord blood from pre-processed, single and double collection Cell type n Cell count/unit ( 10 6 ), mean ± s.e.m. (range) Yield (%), mean ± s.e.m. (range) Pre-processed Single collection Double collection Single collection Double collection P Nucleated cells ± ± ± ± ± ( ) ( ) ( ) ( ) ( ) Mononuclear cells ± ± ± ± ± ( ) ( ) ( ) ( ) ( ) CD ± ± ± ± ± ( ) ( ) ( ) ( ) ( ) Total CFU ± ± ± ± ± ( ) ( ) ( ) ( ) ( )

4 460 the residual cord blood and expressed plasma is mixed and centrifuged to collect the leukocytes lost in the first collection. The end result is increased leukocyte recovery. The velocity ratio of the leukocytes to red blood cells is an important parameter in this separation. It is practically impossible to separate leukocytes from red blood cells without the addition of a strong sedimenting agent, such as HES, or pentastrach. These agents induce rouleaux, or cell packing, which causes the red blood cells to settle more quickly. In the absence of rouleaux, leukocytes would sediment at the same rate due to a similar cell density as red cells. 13 As the packing of red blood cells becomes more and more compact during sedimentation, the spaces between the packed red cells become smaller and smaller. The leukocytes, therefore, concentrate in the channels between packed red cells, and collide. As a result of this collision of leukocytes, recovery of the cells is reduced. 13 This is supported by the work of Akabutu et al 14 who observed that the recovery of leukocytes is inversely proportional to the volume of the cord blood sample. Therefore, to enhance the recovery of trapped leukocytes, the plasma from the first collection can be returned to the residual cord blood and re-centrifuged. There were three concerns raised when the double collection technique was applied. The first was regarding the quality of the recovered cells following two separate collection procedures. It was therefore important to assess the viability of the NC, CD34 + cells, and CFU throughout the procedure. As seen in Table 1, there was no increase in the amount of damage to CD34 + cells and NC following the double collection. This is further exemplified by the fact that the recovery of CFUs was not affected by adding a second collection process (Table 2). The second concern was with the increased length of processing time. A double collection method takes significantly more time than a single collection method, so understanding what effect this will have in the clinical environment is important. For samples of an identical volume, the double collection process will take twice as long as the single collection, but this disadvantage should be compensated for by consistently higher recovery of cells with a lower proportion of samples being discarded. In fact, when there are multiple samples being processed, and each sample has a different volume, the double collection method can be more effective. As each sample has a different volume, a different centrifugation time will be required according to Equation 1 and as a result the samples would need to be processed separately. However, the double collection time is not as sensitive to sample volume (unpublished) and the centrifugation time can be averaged when multiple samples are processed. In practical terms, the double collection technique can be faster than the single collection method as it allows multiple cord blood samples to be processed together using an average centrifugation time (unpublished). The third concern was bacterial and fungal contamination due to the increased number of transfers required during the double collection process. To prevent this, a sterile tubing welder was used to connect transfer bags. This allowed processing of the umbilical cord blood in a closed system. No contamination was detected in any of the processed samples (Table 1). Pentaspan was used in this study to reduce the volume of cord blood instead of the widely used Hespan. In addition to the fact that Hespan is not clinically approved or licensed in a number of countries, like Canada, there are a number of advantages to the use of Pentaspan over HES that makes it more suitable for use in cord blood banking. As HES can be detected years after its administration, 15 the safety of this sedimenting agent has recently been questioned. 16 In comparison, Pentaspan is a lower molecular weight, hetastarch-analog that is cleared from the circulation relatively rapidly. For this reason, and the fact that Pentaspan is equally as effective as HES in inducing red blood cell sedimentation, 17 Pentaspan was used as the sedimenting agent in this study. In conclusion, the double collection technique is an efficient and reproducible method of reducing cord blood volume without depleting the sample of NC, MNC, CD34 + cells and CFU. This procedure has the immediate advantage of decreasing, and perhaps eliminating, the number of clinical samples that are discarded due to low recovery of transplantable cells. Furthermore, by increasing the recovery of stem cells from donated cord blood, more patients, of larger weights, will meet the cell dose criteria required for transplantation. Acknowledgements This study was supported by the Dr Charles Allard Foundation and a grant in aid from the Western Economic Partnership Agreement (Alberta Health and Wellness, Government of Alberta and Western Diversification, Government of Canada), References 1 Broxmeyer HE, Gordon GW, Hangoc G et al. Human umbilical cord blood as a potential source of transplantable hematopoietic stem/progenitor cells. Proc Natl Acad Sci USA 1989; 86: Broxmeyer HE, Hangoc G, Cooper S et al. Growth characteristics and expansion of human umbilical cord blood and estimation of its potential for transplantation in adults. Proc Natl Acad Sci USA 1992; 89: Vaziri H, Dragowska W, Allsop RC et al. Evidence for a mitotic clock in human hematopoietic stem cells: loss of telomeric DNA with age. Proc Natl Acad Sci USA 1994; 91: Rocha V, Wagner JE, Sobocinski KA et al. Graft-versus-host disease in children who have received a cord-blood or bone marrow transplant from an HLA-identical sibling. New Engl J Med 2000; 342: Donaldson C, Armitage WJ, Laundy V et al. Impact of obstetric factors on cord blood donation for transplantation. Br J Haematol 1999; 106: Rubinstein P, Dobrila L, Richard E et al. Processing and cryopreservation of placental/umbilical cord blood for unrelated bone marrow reconstitution. Proc Natl Acad Sci USA 1995; 92: Perutelli P, Gatellani S, Scarso L et al. Processing of human cord blood by three different procedures for red blood cell

5 depletion and mononuclear cell recovery. Vox Sang 1999; 76: Fraser J, Cairo MS, Wagner E et al. Cord blood transplantation study (COBLT): cord blood bank standard operating procedures. J Hematother 1998; 7: Sousa T, De Sousa ME, Godinho MI et al. Umbilical cord blood processing: volume reduction and recovery of CD34 + cells. Bone Marrow Transplant 1997; 19: Gluckman E, Rocha V, Boyer-Chammard A et al. Outcome of cord blood transplantation from related and unrelated donors. New Engl J Med 1997; 337: Keeney M, Chin-Yee I, Weir K et al. Single platform flow cytometric absolute CD34 + cell counts based on the ISHAGE guidelines. Cytometry 1998; 34: Haugland RP. Handbook of Fluorescent Probes and Research Chemicals. Molecular Probes: Eugene, OR, Brown RI. The physics of continuous flow centrifugal cell separation. Artificial Organs 1989; 13: Akabutu J, Yang H, McGann LE. Centralized public banking of umbilical cord blood stem cells: a Canadian perspective. Blood 1999; 94 (Suppl. 1): 10 (Abstr. 2538). 15 Trivedi SM, Humphrey RL, Braine HD et al. Hydroxyethyl starch serum levels in leukapheresis donors measured by modified periodic acid-schiff staining technique. Transfusion 1984; 24: Lee JH, Leitman SF, Klein HG. A controlled comparison of the efficacy of hetastarch and pentastarch in granulocyte collections by centrifugal leukapheresis. Blood 1995; 86: Strauss RG. In vitro comparison of the erythrocytes sedimenting properties of dextran, hydroxyethyl starch and a new low-molecular weight hydroxyethyl starch. Vox Sang 1979; 37:

A simple and reliable procedure for cord blood banking, processing, and freezing: St Louis and Ohio Cord Blood Bank experiences

A simple and reliable procedure for cord blood banking, processing, and freezing: St Louis and Ohio Cord Blood Bank experiences Cytotherapy (2001) Vol. 3, No. 6, 429 433 A simple and reliable procedure for cord blood banking, processing, and freezing: St Louis and Ohio Cord Blood Bank experiences JM Alonso III 1, DM Regan 1, CE

More information

Cell Recovery Sufficient for Adult Transplantation by Additional Cord Blood Collection From Placenta

Cell Recovery Sufficient for Adult Transplantation by Additional Cord Blood Collection From Placenta Cell Recovery Sufficient for Adult Transplantation by Additional Cord Blood Collection From Placenta N. Tsagias, K. Kouzi-Koliakos, D. Hamidi-Alamdari, V. Karagiannis, E. Kostidou, and G. Koliakos ABSTRACT

More information

Automated Cord Blood Processing:

Automated Cord Blood Processing: TM Automated Cord Blood Processing: A Follow-up to the Pilar Solves Study Comparing the AXP vs the Sepax Cord Blood Processing Systems CHRISTY KIM, PETRA CRAVENS, MINDY WILKE-DOUGLAS AND MITCHEL SIVILOTTI

More information

Flow cytometric analysis of stem cells derived from umbilical cord blood CD34+/CD45+ enumeration and viability

Flow cytometric analysis of stem cells derived from umbilical cord blood CD34+/CD45+ enumeration and viability Flow cytometric analysis of stem cells derived from umbilical cord blood CD34+/CD45+ enumeration and viability Doretha Thompson Dissertation in fulfillment of the requirements for the degree Magister Scientiae

More information

UNCORRECTED PROOF AUTHOR S QUERY SHEET. Author(s): G Koliakos et al. MCYT 250711 Article title: Article no: Dear Author

UNCORRECTED PROOF AUTHOR S QUERY SHEET. Author(s): G Koliakos et al. MCYT 250711 Article title: Article no: Dear Author Author(s): G Koliakos et al. MCYT 250711 Article title: Article no: Dear Author AUTHOR S QUERY SHEET The following queries have arisen during the editing of your manuscript and are identified on the proofs.

More information

Cord Blood: Thawing & Infusion Practical Methods

Cord Blood: Thawing & Infusion Practical Methods Cord Blood: Thawing & Infusion Practical Methods Donna M Regan, MT(ASCP)SBB St. Louis Cord Blood Bank @ SSM Cardinal Glennon Children s s Medical Center Objectives Present variety of product configurations

More information

BioArchive Freezing Curve for Cord Blood

BioArchive Freezing Curve for Cord Blood BioArchive Freezing Curve for Cord Blood Determination of the Specific Freezing in the BioArchive System to Provide the Highest Viability of Cord Blood MNC as Measured by -C Assays Introduction Freezing

More information

Umbilical cord blood collection and separation for haematopoietic progenitor cell banking

Umbilical cord blood collection and separation for haematopoietic progenitor cell banking Bone Marrow Transplantation, (1997) 19, 1023 1028 1997 Stockton Press All rights reserved 0268 3369/97 $12.00 Umbilical cord blood collection and separation for haematopoietic progenitor cell banking JA

More information

Automated and Standardized Counting of CFU Assays of Human Hematopoietic Cells

Automated and Standardized Counting of CFU Assays of Human Hematopoietic Cells Automated and Standardized Counting of CFU Assays of Human Hematopoietic Cells 2 Automated and Standardized Colony Counting Table of Contents 4 Standardized Counting of Colony-Forming Unit Assays (CFU)

More information

STEMCELL Quality Control Kits

STEMCELL Quality Control Kits STEMCELL Quality Control Kits i Table of Contents 1.0 Introduction...1 2.0 Thawing Cells, Plating and Colony Enumeration...2 2.1 Supplies and reagents included in the QC kit...2 2.2 Additional reagents

More information

Public Cord Blood Banking at the National Cord Blood Program (NCBP)

Public Cord Blood Banking at the National Cord Blood Program (NCBP) Public Cord Blood Banking at the National Cord Blood Program (NCBP) A. Scaradavou, MD Medical Director, National Cord Blood Program, New York Blood Center Associate Attending, Pediatric BMT Memorial Sloan-Kettering

More information

How To Transplant Cord Blood

How To Transplant Cord Blood MP 7.01.38 Placental/Umbilical Cord Blood as a Source of Stem Cells Medical Policy Section Surgery Issue 12:2013 Original Policy Date 12:2013 Last Review Status/Date Reviewed with literature search/12:2013

More information

Optimal timing for processing and cryopreservation of umbilical cord haematopoietic stem cells for clinical transplantation

Optimal timing for processing and cryopreservation of umbilical cord haematopoietic stem cells for clinical transplantation Bone Marrow Transplantation, (1999) 23, 131 136 1999 Stockton Press All rights reserved 268 3369/99 $12. http://www.stockton-press.co.uk/bmt Optimal timing for processing and cryopreservation of umbilical

More information

Racial Diversity with High Nucleated Cell Counts and CD34 Counts Achieved in a National Network of Cord Blood Banks

Racial Diversity with High Nucleated Cell Counts and CD34 Counts Achieved in a National Network of Cord Blood Banks Biology of Blood and Marrow Transplantation 10:269-275 (2004) 2004 American Society for Blood and Marrow Transplantation 1083-8791/04/1004-0006$30.00/0 doi:10.1016/j.bbmt.2003.12.003 Racial Diversity with

More information

Preparation of cord blood for infusion: bedside thaw, dilute and wash, or somewhere in between

Preparation of cord blood for infusion: bedside thaw, dilute and wash, or somewhere in between Preparation of cord blood for infusion: bedside thaw, dilute and wash, or somewhere in between Donna Wall, MD Director, Manitoba Blood and Marrow Transplant Program ISCT 2012 Disclosures: none The problem:

More information

Recommendations to Transplant Centres Performing Cord Blood Transplants. Why Choosing the Right Thaw Method Could Save a Patient s Life

Recommendations to Transplant Centres Performing Cord Blood Transplants. Why Choosing the Right Thaw Method Could Save a Patient s Life Recommendations to Transplant Centres Performing Cord Blood Transplants Vicki Antonenas Why Choosing the Right Thaw Method Could Save a Patient s Life Lynn O Donnell (USA) 1 The process of receiving, testing

More information

Improved Ex Vivo Expansion of Functional CD34 + Cells Using Stemline II Hematopoietic Stem Cell Expansion Medium

Improved Ex Vivo Expansion of Functional CD34 + Cells Using Stemline II Hematopoietic Stem Cell Expansion Medium Improved Ex Vivo Expansion of Functional CD34 + Cells Using Stemline II Hematopoietic Stem Cell Expansion Medium Daniel W. Allison, 1 Stacy L. Leugers, 1 Barry J. Pronold, 2 Gary Van Zant, 2 Jenny A. Harrington,

More information

Basic Science in Medicine

Basic Science in Medicine Medical Journal of th e Islamic Republic of Iran Volume 18 Number 3 Fall 1383 November 2004 Basic Science in Medicine ] EXPANSION OF HUMAN CORD BLOOD PRIMITIVE PROGENITORS IN SERUM-FREE MEDIA USING HUMAN

More information

UMBILICAL CORD BLOOD TRANSPLANTATION: KFSH EXPERIENCE

UMBILICAL CORD BLOOD TRANSPLANTATION: KFSH EXPERIENCE UMBILICAL CORD BLOOD TRANSPLANTATION: KFSH EXPERIENCE HIND AL HUMAIDAN, MD,FRCPA Director, Blood Bank (Donor & Transfusion Services) and Stem Cell Cord Blood Bank Consultant Hematopathologist INTRODUCTION

More information

Review. Cord blood as an alternative source of haemopoietic stem cells. J. Hows, A. Nicol, P. Denning-Kendall, C. Donaldson, M. Nieda & B.

Review. Cord blood as an alternative source of haemopoietic stem cells. J. Hows, A. Nicol, P. Denning-Kendall, C. Donaldson, M. Nieda & B. Annals of Oncology 7 (Suppi 2): 47-51, 1996. O 1996 Kluwer Academic Publishers. Printed in the Netherlands. Review Cord blood as an alternative source of haemopoietic stem cells J. Hows, A. Nicol, P. Denning-Kendall,

More information

Automated and Standardized Counting of CFU Assays for Cord Blood Banks

Automated and Standardized Counting of CFU Assays for Cord Blood Banks Automated and Standardized Counting of CFU Assays for Cord Blood Banks 2 Automated and Standardized Colony Counting Table of Contents 4 The Colony-Forming Unit (CFU) Assay for Cord Blood Banks 5 The CFU

More information

Enumeration and Viability of Nucleated Cells from Bone Marrow, Cord Blood, and Mobilized Peripheral Blood

Enumeration and Viability of Nucleated Cells from Bone Marrow, Cord Blood, and Mobilized Peripheral Blood Application Note Primary Cell Analysis Enumeration and Viability of Nucleated Cells from Bone Marrow, Cord Blood, and Mobilized Peripheral Blood Cell Viability Introduction: Bone Marrow, Cord Blood, Stem

More information

AUTOMATION OF THE COLONY-FORMING CELL ASSAY FOR MEASURING HEMATOPOIETIC PROGENITORS IN CORD BLOOD

AUTOMATION OF THE COLONY-FORMING CELL ASSAY FOR MEASURING HEMATOPOIETIC PROGENITORS IN CORD BLOOD AUTOMATION OF THE COLONY-FORMING CELL ASSAY FOR MEASURING HEMATOPOIETIC PROGENITORS IN CORD BLOOD Bert Wognum Oliver Egeler Caren Grande Ning Yuan Steven Woodside Terry Thomas Allen Eaves STEMCELL Technologies

More information

CORD BLOOD BANKING FAQ

CORD BLOOD BANKING FAQ CORD BLOOD BANKING FAQ Cord Blood & Stem Cells Q: What is umbilical cord blood (UCB)? A: Bone marrow, peripheral blood and UCB constitute the three primary sources of stem cells. Cord blood, which, until

More information

BLOOD COMPONENTS. Liquid storage, shipment, and cryopreservation of cord blood. Allison Hubel, Dale Carlquist, Mary Clay, and Jeff McCullough

BLOOD COMPONENTS. Liquid storage, shipment, and cryopreservation of cord blood. Allison Hubel, Dale Carlquist, Mary Clay, and Jeff McCullough Blackwell Science, LtdOxford, UKTRFTransfusion0041-11322004 American Association of Blood BanksApril 2004444Original ArticleLIQUID AND FROZEN STORAGE OF CORD BLOODHUBEL ET AL. BLOOD COMPONENTS Liquid storage,

More information

Comparison of Three Methods in Umbilical Cord Blood Collection for Hematopoietic Stem Cell Transplantation

Comparison of Three Methods in Umbilical Cord Blood Collection for Hematopoietic Stem Cell Transplantation Thai Journal of Obstetrics and Gynaecology September 2002, Vol. 14, pp. 183-192 OBSTETRICS Comparison of Three Methods in Umbilical Cord Blood Collection for Hematopoietic Stem Cell Transplantation Dennopporn

More information

UMBILICAL CORD BLOOD COLLECTION

UMBILICAL CORD BLOOD COLLECTION UMBILICAL CORD BLOOD COLLECTION by Frances Verter, PhD Founder & Director, Parent's Guide to Cord Blood Foundation info@parentsguidecordblood.org and Kim Petrella, RN Department of Obstetrics and Gynecology

More information

Correlation of umbilical cord blood volume with CD34+ cells concentration

Correlation of umbilical cord blood volume with CD34+ cells concentration IJBTI 2011 ;1 :11-1 5. Chandra et al. 11 ORIGINAL ARTICLE OPEN ACCESS Correlation of umbilical cord blood volume with CD34+ cells concentration Tulika Chandra, Sheeba Afreen, Ashutosh Kumar, Uma Singh

More information

Sibling Donor Cord Blood Transplantation for Thalassemia Major: Experience of the Sibling Donor Cord Blood Program

Sibling Donor Cord Blood Transplantation for Thalassemia Major: Experience of the Sibling Donor Cord Blood Program Sibling Donor Cord Blood Transplantation for Thalassemia Major: Experience of the Sibling Donor Cord Blood Program MARK C. WALTERS, LYNN QUIROLO, ELIZABETH T. TRACHTENBERG, SANDIE EDWARDS, LISA HALE, JOANNA

More information

Analyzing Samples for CD34 Enumeration Using the BD Stem Cell Enumeration Kit

Analyzing Samples for CD34 Enumeration Using the BD Stem Cell Enumeration Kit 2 Analyzing Samples for CD34 Enumeration Using the BD Stem Cell Enumeration Kit Presented by Ellen Meinelt, MS MLS(ASCP) CM, Technical Applications Specialist and Calin Yuan, Product Course Developer,

More information

No-wash, no-lyse detection of leukocytes in human whole blood on the Attune NxT Flow Cytometer

No-wash, no-lyse detection of leukocytes in human whole blood on the Attune NxT Flow Cytometer APPLICATION NOTE Attune NxT Flow Cytometer No-wash, no-lyse detection of leukocytes in human whole blood on the Attune NxT Flow Cytometer Introduction Standard methods for isolating and detecting leukocytes

More information

Jennifer G. Collins, RN Children s Hospital of Chicago

Jennifer G. Collins, RN Children s Hospital of Chicago Jennifer G. Collins, RN Children s Hospital of Chicago Review the importance of consultation with the stem cell transplant team Review criteria to begin harvest Review ways to modify a harvest procedure

More information

APPLICATION INFORMATION

APPLICATION INFORMATION DRAFT: Rev. D A-2045A APPLICATION INFORMATION Flow Cytometry 3-COLOR COMPENSATION Raquel Cabana,* Mark Cheetham, Jay Enten, Yong Song, Michael Thomas,* and Brendan S. Yee Beckman Coulter, Inc., Miami FL

More information

WHOLE BLOOD LYSING SOLUTION FOR FLOW CYTOMETRIC APPLICATIONS

WHOLE BLOOD LYSING SOLUTION FOR FLOW CYTOMETRIC APPLICATIONS FOR IN-VITRO DIAGNOSTIC USE INVITROGEN CAL-LYSE TM Lysing Solution WHOLE BLOOD LYSING SOLUTION FOR FLOW CYTOMETRIC APPLICATIONS CAL-LYSE TM CATALOG No. GAS-010 250 tests 25 ml CATALOG No. GAS-010S-100

More information

A Public Cord Blood Bank for South Africa? i

A Public Cord Blood Bank for South Africa? i No. 42/2007 A Public Cord Blood Bank for South Africa? i By Dr Robert Crookes MBChB (Wits), Dip. Internal Medicine (American Board of Internal Medicine, USA) Transfusion Medicine Consultant. South African

More information

Transmedcon 2014. Ahmedabad, Gujarat November 14-16, 2014

Transmedcon 2014. Ahmedabad, Gujarat November 14-16, 2014 FACT Accreditation for Cord Blood Banks and Cellular Therapy Nadim Mahmud, MD, PhD Associate Professor of Medicine Division of Hematology/Oncology Director, Hospital Stem Cell Laboratory Blood & Marrow

More information

14.0 Stem Cell Laboratory Services

14.0 Stem Cell Laboratory Services Laboratory Services Contact Information: To inquire about assisting with surgical harvesting of bone marrow, cellular therapy (CT) product processing, cryopreservation, storage, or any other lab services,

More information

Guidance for Industry and FDA Staff

Guidance for Industry and FDA Staff Guidance for Industry and FDA Staff Investigational New Drug Applications for Minimally Manipulated, Unrelated Allogeneic Placental/Umbilical Cord Blood Intended for Hematopoietic and Immunologic Reconstitution

More information

The Power & Potential of Cord Blood

The Power & Potential of Cord Blood The Power & Potential of Cord Blood Donna Regan, MT(ASCP)SBB, Director St. Louis Cord Blood Bank & Cellular Therapy Laboratory SSM Cardinal Glennon Children s Medical Center April 30, 2014 Objectives Since

More information

Proliferation/Potency Assays: Is there more to CD34 and CFU?

Proliferation/Potency Assays: Is there more to CD34 and CFU? Proliferation/Potency Assays: Is there more to CD34 and CFU? CBMTG 2012 Laboratory Committee Meeting April 11, 2012 Toronto, ON, Canada Leah Marquez-Curtis CBS-Edmonton OUTLINE I. Rationale and Definitions

More information

Cord Blood Collection, Processing and Freezing Bag Sets for the Cryopreservation of Blood and Cellular Components

Cord Blood Collection, Processing and Freezing Bag Sets for the Cryopreservation of Blood and Cellular Components Cord Blood Collection, Processing and Freezing Bag Sets for the Cryopreservation of Blood and Cellular Components Facilitate each step in the collection, processing, freezing and transfusion process for

More information

Cord blood stem cells Where do we stand?

Cord blood stem cells Where do we stand? Mædica - a Journal of Clinical Medicine STATE TE-OF OF-THE THE-AR ART Cord blood stem cells Where do we stand? Ana Maria VLADAREANU, Associate Professor of Hematology, MD, PhD a, Doina MIHAILESCU b, MD,

More information

Cord Blood Collections for the Texas Cord Blood Bank. Obstetrical Providers Training Module

Cord Blood Collections for the Texas Cord Blood Bank. Obstetrical Providers Training Module Cord Blood Collections for the Texas Cord Blood Bank Obstetrical Providers Training Module The Texas Cord Blood Bank The Texas Cord Blood Bank is a network of maternity hospitals and a central laboratory

More information

Fetal Maternal Immunity and Antileukemia Activity in Cord Blood Transplant. Recipients

Fetal Maternal Immunity and Antileukemia Activity in Cord Blood Transplant. Recipients Fetal Maternal Immunity and Antileukemia Activity in Cord Blood Transplant Recipients Filippo Milano, 1 J. Lee Nelson, 1, 2 Colleen Delaney 1,3 1 Clinical Research Division, Fred Hutchinson Cancer Research

More information

Placental and Umbilical Cord Blood as a Source of Stem Cells

Placental and Umbilical Cord Blood as a Source of Stem Cells Placental and Umbilical Cord Blood as a Source of Stem Cells Policy Number: 7.01.50 Last Review: 12/2013 Origination: 12/2001 Next Review: 12/2014 Policy Blue Cross and Blue Shield of Kansas City (Blue

More information

Automated separation of cord blood units in top and bottom bags using the Compomat G4

Automated separation of cord blood units in top and bottom bags using the Compomat G4 Clin. Lab. Haem. 2006, 28, 202 207 P. SOLVES, V. MIRABET, F. CARBONELL- UBEROS, M. A. SOLER, R. ROIG Summary Keywords Automated separation of cord blood units in top and bottom bags using the Compomat

More information

In a number of genetic, hematologic, and oncologic

In a number of genetic, hematologic, and oncologic AMERICAN ACADEMY OF PEDIATRICS Cord Blood Banking for Potential Future Transplantation: Subject Review ABSTRACT. In recent years, umbilical cord blood, which contains a large number of hematopoietic stem

More information

Review Article A Review of Factors Influencing the Banking of Collected Umbilical Cord Blood Units

Review Article A Review of Factors Influencing the Banking of Collected Umbilical Cord Blood Units Stem Cells International Volume 2013, Article ID 463031, 7 pages http://dx.doi.org/10.1155/2013/463031 Review Article A Review of Factors Influencing the Banking of Collected Umbilical Cord Blood Units

More information

Stepcount. Product Description: Closed transparent tubes with a metal screen, including a white matrix at the bottom. Cat. Reference: STP-25T

Stepcount. Product Description: Closed transparent tubes with a metal screen, including a white matrix at the bottom. Cat. Reference: STP-25T Product Description: Closed transparent tubes with a metal screen, including a white matrix at the bottom Cat. Reference: STP-25T Reagent provided:: 25 Stepcount tubes for 25 test INTENDED USE. Immunostep

More information

The success of bone marrow or peripheral blood stem

The success of bone marrow or peripheral blood stem CD34 + Cell Enumeration by Flow Cytometry A Comparison of Systems and Methodologies Alain Ngoma, MD; Shunnichi Saito, MT; Hitoshi Ohto, MD, PhD; Kazuhiko Ikeda, MD, PhD; Hiroyasu Yasuda, PhD; Kinuyo Kawabata,

More information

CHAPTER 3 COLLECTION PROCEDURES

CHAPTER 3 COLLECTION PROCEDURES CHAPTER 3 COLLECTION PROCEDURES Chapter 3 COLLECTION PROCEDURES 3.1 COLLECTION KIT Principle The cord blood collection kit will be carefully assembled by the Cord Blood Bank (CBB) supervisor or his/her

More information

Selecting an appropriately matched donor for hematopoietic

Selecting an appropriately matched donor for hematopoietic Transplant Outcomes in Acute Leukemia (I) Mary Eapen a and John E. Wagner b Umbilical cord blood (UCB) has gradually emerged over the last decade as an alternative source of hematopoietic cells for transplantation

More information

Standardization, Calibration and Quality Control

Standardization, Calibration and Quality Control Standardization, Calibration and Quality Control Ian Storie Flow cytometry has become an essential tool in the research and clinical diagnostic laboratory. The range of available flow-based diagnostic

More information

Cord Blood: that other stem cell source. Donna Wall, MD Director, Manitoba Blood and Marrow Transplant Program

Cord Blood: that other stem cell source. Donna Wall, MD Director, Manitoba Blood and Marrow Transplant Program Cord Blood: that other stem cell source Donna Wall, MD Director, Manitoba Blood and Marrow Transplant Program CBMTG April 2012 The problem: In order to perform a BMT from one person to another one needs

More information

Placental and Umbilical Cord Blood as a Source of Stem Cells

Placental and Umbilical Cord Blood as a Source of Stem Cells Placental and Umbilical Cord Blood as a Source of Stem Cells Policy Number: 7.01.50 Last Review: 12/2015 Origination: 12/2001 Next Review: 12/2016 Policy Blue Cross and Blue Shield of Kansas City (Blue

More information

Equine Stem Cells. Sources, Processing, Expansion, Storage and Shipping

Equine Stem Cells. Sources, Processing, Expansion, Storage and Shipping Equine Stem Cells Sources, Processing, Expansion, Storage and Shipping Sean Owens, DVM, Diplomate ACVP Medical Director, UC Davis Veterinary Regenerative Medicine Laboratory What is a Stem Cell and What

More information

The Power & Potential of Cord Blood

The Power & Potential of Cord Blood The Power & Potential of Cord Blood Donna Regan, MT(ASCP)SBB, Director St. Louis Cord Blood Bank & Cellular Therapy Laboratory SSM Cardinal Glennon Children s Medical Center September 18, 2013 Objectives

More information

Saving your baby s s cord blood: Is this good insurance?

Saving your baby s s cord blood: Is this good insurance? Saving your baby s s cord blood: Is this good insurance? 32 th SEMINAR ON PERINATAL MEDICINE CONTROVERSIES IN PERINATAL MEDICINE: EVIDENCE FOR CURRENT PRACTICE Sante Fe, New Mexico Mervin C. Yoder, MD

More information

Umbilical Cord Blood Transplantation

Umbilical Cord Blood Transplantation Umbilical Cord Blood Transplantation V Rocha MD, PhD Hopital Saint Louis, Paris University 7 CIBMTR Milwaukee Umbilical Cord blood transplantation Background History Clinical results in children and adults

More information

Processing & Utilization of Cord Blood for Transplant

Processing & Utilization of Cord Blood for Transplant Processing & Utilization of Cord Blood for Transplant 2010-Jan Jan-15 Nicole L. Prokopishyn, PhD HPC Processing Laboratory Director Calgary Laboratory Services Overview Cord Blood Processing Pre-Freeze

More information

Cord Blood Re-imagined The use of cord blood stem cells for clinical applications and medical innovations

Cord Blood Re-imagined The use of cord blood stem cells for clinical applications and medical innovations GE Healthcare Proceedings of the Symposium Cord Blood Re-imagined The use of cord blood stem cells for clinical applications and medical innovations 12 th Annual Meeting of the International Society for

More information

For in vitro preparation of human mononuclear cells from peripheral blood, bone marrow, and umbilical cord blood. Not for in vitro diagnostic use.

For in vitro preparation of human mononuclear cells from peripheral blood, bone marrow, and umbilical cord blood. Not for in vitro diagnostic use. GE Healthcare Instructions 28-4039-56 AA Cell Preparation Media Ficoll-Paque PREMIUM Intended use For in vitro preparation of human mononuclear cells from peripheral blood, bone marrow, and umbilical cord

More information

A Cure for Sickle Cell Anemia and Thalassemia

A Cure for Sickle Cell Anemia and Thalassemia IV Simpósio Internacional de Hemoglobinopatias A Cure for Sickle Cell Anemia and Thalassemia Bertram Lubin, MD and Mark Walters, MD 4 September 2007 Topics to be covered Cord blood: Importance and biology

More information

Meta-Analysis of the AXP and Sepax Automated Cord Blood Processing Systems

Meta-Analysis of the AXP and Sepax Automated Cord Blood Processing Systems TM Meta-Analysis of the AXP and Sepax Automated Cord Blood Processing Systems CHRISTY KIM, MINDY WILKE-DOUGLAS, AND MITCHEL SIVILOTTI Introduction Automation is the key to standardizing cord blood processing.

More information

123count ebeads Catalog Number: 01-1234 Also known as: Absolute cell count beads GPR: General Purpose Reagents. For Laboratory Use.

123count ebeads Catalog Number: 01-1234 Also known as: Absolute cell count beads GPR: General Purpose Reagents. For Laboratory Use. Page 1 of 1 Catalog Number: 01-1234 Also known as: Absolute cell count beads GPR: General Purpose Reagents. For Laboratory Use. Normal human peripheral blood was stained with Anti- Human CD45 PE (cat.

More information

The donor search: the best donor or cord blood unit

The donor search: the best donor or cord blood unit The donor search: the best donor or cord blood unit Dr Bronwen Shaw Consultant in haematopoietic cell transplantation Royal Marsden Hospital /Anthony Nolan Overview Where do we find donors/units for transplantation

More information

Dr Saeed Al Amoudi. Consultant Hematologist King s college hospital Director of Regional Lab Jeddah

Dr Saeed Al Amoudi. Consultant Hematologist King s college hospital Director of Regional Lab Jeddah Dr Saeed Al Amoudi Consultant Hematologist King s college hospital Director of Regional Lab Jeddah MAGIC BULLET Cord Blood Banking What is Cord Blood? Cord blood is the blood left in the placenta and umbilical

More information

CHAPTER 1 BACKGROUND AND CORD BLOOD BANK (CBB) ORGANIZATION

CHAPTER 1 BACKGROUND AND CORD BLOOD BANK (CBB) ORGANIZATION CHAPTER 1 BACKGROUND AND CORD BLOOD BANK (CBB) ORGANIZATION Chapter 1 BACKGROUND AND CORD BLOOD BANK (CBB) ORGANIZATION 1.1 OVERVIEW OF THE CORD BLOOD TRANSPLANTATION STUDY Bone marrow transplantation

More information

Fresh PBSC harvests, but not BM, show temperature-related loss of CD34 viability during storage and transport

Fresh PBSC harvests, but not BM, show temperature-related loss of CD34 viability during storage and transport Cytotherapy (2006) Vol. 8, No. 2, 158/165 Fresh PBSC harvests, but not BM, show temperature-related loss of CD34 viability during storage and transport V Antonenas 1, F Garvin 1, M Webb 1, M Sartor 2,

More information

Guidance for Industry

Guidance for Industry Guidance for Industry Class II Special Controls Guidance Document: Cord Blood Processing System and Storage Container This guidance is for immediate implementation. FDA is issuing this guidance for immediate

More information

4. All cord blood banks should be subject to the same standards, regulations and accreditation requirements.

4. All cord blood banks should be subject to the same standards, regulations and accreditation requirements. WMDA Policy Statement on the Utility of Autologous or Family Cord Blood Unit Storage The WMDA Board adopted this policy on 25 th of May 2006. Policy updated _April 2011 The Cord Blood Working Group and

More information

The Impact of Maternal, Neonatal and Collections factors on the TNC count of an Umbilical Cord Blood Donation

The Impact of Maternal, Neonatal and Collections factors on the TNC count of an Umbilical Cord Blood Donation The Impact of Maternal, Neonatal and Collections factors on the TNC count of an Umbilical Cord Blood Donation By: NHS Cord Blood Bank (Colindale Laboratory) Date: 26 th September 2014 NHS insert Cord your

More information

Status of umbilical cord blood transplantation in the year 2001

Status of umbilical cord blood transplantation in the year 2001 428 J Clin Pathol 2001;54:428 434 Status of umbilical cord blood transplantation in the year 2001 JMHows Abstract Umbilical cord blood (UCB) transplantation is limited to small recipients because of the

More information

Detecting primitive hematopoietic stem cells in total nucleated and mononuclear cell fractions from umbilical cord blood segments and units

Detecting primitive hematopoietic stem cells in total nucleated and mononuclear cell fractions from umbilical cord blood segments and units Patterson et al. Journal of Translational Medicine (2015) 13:94 DOI 10.1186/s12967-015-0434-z RESEARCH Open Access Detecting primitive hematopoietic stem cells in total nucleated and mononuclear cell fractions

More information

Directed/Related Cord Blood Collection by NHS Blood and Transplant

Directed/Related Cord Blood Collection by NHS Blood and Transplant Directed/Related Cord Blood Collection by Jacqui Thompson Clinical Scientist Section Head of Specialist Procedures Stem Cells and Immunotherapies Department National Blood Service, NHSBT Birmingham Why

More information

Guidelines for Collection, Processing, and Storage of Cord Blood Stem Cells Second Edition March 2003

Guidelines for Collection, Processing, and Storage of Cord Blood Stem Cells Second Edition March 2003 Guidelines for Collection, Processing, and Storage of Cord Blood Stem Cells Second Edition March 2003 New York State Council on Human Blood and Transfusion Services New York State Department of Health

More information

STEM CELL LEUCOCYTE BIOLOGY. Setting up of an Umbilical cord blood stem cell bank at Institute of Immunohaematology

STEM CELL LEUCOCYTE BIOLOGY. Setting up of an Umbilical cord blood stem cell bank at Institute of Immunohaematology STEM CELL LEUCOCYTE BIOLOGY Setting up of an Umbilical cord blood stem cell bank at Institute of Immunohaematology Objectives: 1. To establish umbilical cord blood stem cell bank, which can be used as

More information

Umbilical Cord Blood Stem Cells Current Status & Future Potential

Umbilical Cord Blood Stem Cells Current Status & Future Potential Umbilical Cord Blood Stem Cells Current Status & Future Potential Natasha Ali Assistant Professor Haematology Department of Pathology & Laboratory Medicine/Oncology The Aga Khan University Email: natasha.ali@aku.edu

More information

Canadian Blood Services National Public Cord Blood Bank Give Life Twice Transfusion Medicine Residents

Canadian Blood Services National Public Cord Blood Bank Give Life Twice Transfusion Medicine Residents Canadian Blood Services National Public Cord Blood Bank Give Life Twice Transfusion Medicine Residents Eileen Quinlan Collection Supervisor, Brampton (GTA) 2015-11-10 History One Match Stem Cell and Marrow

More information

Section: Transplant Last Reviewed Date: January 2015. Policy No: 45.16 Effective Date: April 1, 2015

Section: Transplant Last Reviewed Date: January 2015. Policy No: 45.16 Effective Date: April 1, 2015 Medical Policy Manual Topic: Placental and Umbilical Cord Blood as a Source of Stem Cells Date of Origin: December 2009 Section: Transplant Last Reviewed Date: January 2015 Policy No: 45.16 Effective Date:

More information

Placental and Umbilical Cord Blood as a Source of Stem Cells

Placental and Umbilical Cord Blood as a Source of Stem Cells Placental and Umbilical Cord Blood as a Source of Stem Cells Policy Number: 7.01.50 Last Review: 12/2014 Origination: 12/2001 Next Review: 12/2015 Policy Blue Cross and Blue Shield of Kansas City (Blue

More information

Helping you find the one match.. Guide for Unrelated Stem Cell Transplant Patients OneMatch Stem Cell and Marrow Network BLOOD.

Helping you find the one match.. Guide for Unrelated Stem Cell Transplant Patients OneMatch Stem Cell and Marrow Network BLOOD. Helping you find the one match.. Guide for Unrelated Stem Cell Transplant Patients OneMatch Stem Cell and Marrow Network BLOOD.CA WWW This guide is intended for patients in need of an unrelated volunteer

More information

CPT Codes for Bone Marrow Transplant January 2015 James L. Gajewski, MD

CPT Codes for Bone Marrow Transplant January 2015 James L. Gajewski, MD The blood and marrow transplant field has 15 dedicated CPT codes. These CPT codes can be categorized into three groups: 1. Collection Codes 2. Cell Processing Codes 3. Cell Infusion Codes Collection Codes

More information

CORD BLOOD TRANSPLANTATION: PAST, PRESENT AND FUTURE

CORD BLOOD TRANSPLANTATION: PAST, PRESENT AND FUTURE CORD BLOOD TRANSPLANTATION: PAST, PRESENT AND FUTURE Dennis M. Todd, Ph.D. The New Jersey Cord Blood Bank a Division of Bergen Community Regional Blood Center Montvale, NJ Hematopoietic Stem Cell Transplantation

More information

CIGNA HEALTHCARE COVERAGE POSITION

CIGNA HEALTHCARE COVERAGE POSITION CIGNA HEALTHCARE COVERAGE POSITION Subject Umbilical Cord Blood Banking Table of Contents Coverage Position... 1 General Background... 1 Coding/Billing Information... 3 References... 3 Revised Date...

More information

Evaluation of Volume and Total Nucleated Cell Count as Cord Blood Selection Parameters A Receiver Operating Characteristic Curve Modeling Approach

Evaluation of Volume and Total Nucleated Cell Count as Cord Blood Selection Parameters A Receiver Operating Characteristic Curve Modeling Approach Hematopathology / Umbilical Cord Blood Selection Evaluation of Volume and Total Nucleated Cell Count as Cord Blood Selection Parameters A Receiver Operating Characteristic Curve Modeling Approach José

More information

Hematopoiesis i starts from. HPC differentiates t to sequentially more mature. HPC circulate in very low

Hematopoiesis i starts from. HPC differentiates t to sequentially more mature. HPC circulate in very low Upstate Cord Blood Bank Hematopoietic Progenitor Cells Hematopoiesis i starts from self renewing HPC HPC differentiates t to sequentially more mature blood cells HPC circulate in very low numbers in adults

More information

Name of Policy: Placental/Umbilical Cord Blood as a Source of Stem Cells

Name of Policy: Placental/Umbilical Cord Blood as a Source of Stem Cells Name of Policy: Placental/Umbilical Cord Blood as a Source of Stem Cells Policy #: 439 Latest Review Date: September 2014 Category: Medical Policy Grade: A Background/Definitions: As a general rule, benefits

More information

Standard Operating Procedure

Standard Operating Procedure 1.0 Purpose: 1.1 The characterisation of of main leukocyte subsets in peripheral blood cells from mice by flow cytometry. Reliable values of frequencies of leukocyte clusters are very much dependent on

More information

SAVE A LIFE... BY GIVING LIFE!

SAVE A LIFE... BY GIVING LIFE! SAVE A LIFE... BY GIVING LIFE! FOLLOW US ON: HÉMA-QUÉBEC PUBLIC CORD BLOOD BANK www.hema-quebec.qc.ca Scan this code with your smart phone to access the page Register to the Public Cord Blood Bank on the

More information

Processing Cord Blood With the SynGenX -1000 System

Processing Cord Blood With the SynGenX -1000 System Processing Cord Blood With the SynGenX -1000 System üadvanced ü Technology for Cell Separation and Cryopreservation ühigh ü CD34, TNC, MNC Recovery and Post Thaw Viability ücritical ü Process Control with

More information

Stem Cell Background Paper

Stem Cell Background Paper Stem Cell Background Paper Introduction...2 Stem Cell Basics...3 Stem Cell Process Flow...9 Comparison of Blood, Stem Cells, Tissues and Organs Processes...10 Responsibilities for the Blood, Stem Cells,

More information

CHAPTER 7 QUALITY ASSESSMENT

CHAPTER 7 QUALITY ASSESSMENT CHAPTER 7 QUALITY ASSESSMENT Chapter 7 QUALITY ASSESSMENT 7.1 OVERVIEW OF CBB-SPECIFIC QUALITY ASSURANCE/QUALITY CONTROL PROGRAM An extensive, site-specific Quality Assurance/Quality Control (QA/QC) program

More information

INFORMATION ON STEM CELLS/BONE MARROW AND REINFUSION/TRANSPLANTATION SUR703.002

INFORMATION ON STEM CELLS/BONE MARROW AND REINFUSION/TRANSPLANTATION SUR703.002 INFORMATION ON STEM CELLS/BONE MARROW AND REINFUSION/TRANSPLANTATION SUR703.002 COVERAGE: SPECIAL COMMENT ON POLICY REVIEW: Due to the complexity of the Peripheral and Bone Marrow Stem Cell Transplantation

More information

Studies on Practical Issues for Cord Blood Banking: Effects of Ionizing Radiation and Cryopreservation Variables

Studies on Practical Issues for Cord Blood Banking: Effects of Ionizing Radiation and Cryopreservation Variables The Open Stem Cell Journal, 2010, 2, 37-44 37 Open Access Studies on Practical Issues for Cord Blood Banking: Effects of Ionizing Radiation and Cryopreservation Variables David T. Harris,1, Jianhua Wang

More information

5. All cord blood banks should be subject to the same standards, regulations and accreditation requirements.

5. All cord blood banks should be subject to the same standards, regulations and accreditation requirements. WMDA Policy Statement for the Utility of Autologous or Family Cord Blood Unit Storage (This policy statement has been approved and adopted by the WMDA board on the 25 th of May 2006) The Cord Blood Registries

More information

Biomedical Research 2012; 23 (3): 395-401 ISSN 0970-938X Scientific Publishers of India

Biomedical Research 2012; 23 (3): 395-401 ISSN 0970-938X Scientific Publishers of India Biomedical Research 2012; 23 (3): 395-401 ISSN 0970-938X Scientific Publishers of India Evaluation of procedures for quantification of CD34 + haematopoietic stem cells and viability studies in umbilical

More information

Ficoll-Paque PREMIUM Ficoll-Paque PREMIUM 1.084 Ficoll-Paque PREMIUM 1.073

Ficoll-Paque PREMIUM Ficoll-Paque PREMIUM 1.084 Ficoll-Paque PREMIUM 1.073 Instructions 28-4039-56 AE Cell Preparation Media Ficoll-Paque PREMIUM Ficoll-Paque PREMIUM 1.084 Ficoll-Paque PREMIUM 1.073 Intended use For in vitro isolation of mononuclear cells and/or granulocytes

More information

CBS National Public Cord Blood Bank. Did you donate your cord blood?

CBS National Public Cord Blood Bank. Did you donate your cord blood? CBS National Public Cord Blood Bank Did you donate your cord blood? Tanya Petraszko MD FRCPC October 2014 Overview What is a stem cell? The importance of HLA Need for cord blood stem cells For all Canadians

More information

POLICY PRODUCT VARIATIONS DESCRIPTION/BACKGROUND RATIONALE DEFINITIONS BENEFIT VARIATIONS DISCLAIMER CODING INFORMATION REFERENCES POLICY HISTORY

POLICY PRODUCT VARIATIONS DESCRIPTION/BACKGROUND RATIONALE DEFINITIONS BENEFIT VARIATIONS DISCLAIMER CODING INFORMATION REFERENCES POLICY HISTORY Original Issue Date (Created): 4/1/2011 Most Recent Review Date (Revised): 3/24/2015 Effective Date: 6/1/2015 POLICY PRODUCT VARIATIONS DESCRIPTION/BACKGROUND RATIONALE DEFINITIONS BENEFIT VARIATIONS DISCLAIMER

More information