The success of bone marrow or peripheral blood stem

Size: px
Start display at page:

Download "The success of bone marrow or peripheral blood stem"

Transcription

1 CD34 + Cell Enumeration by Flow Cytometry A Comparison of Systems and Methodologies Alain Ngoma, MD; Shunnichi Saito, MT; Hitoshi Ohto, MD, PhD; Kazuhiko Ikeda, MD, PhD; Hiroyasu Yasuda, PhD; Kinuyo Kawabata, MT; Takahiro Kanno, MD, PhD; Atsushi Kikuta, MD, PhD; Kazuhiro Mochizuki, MD, PhD; Kenneth E. Nollet, MD, PhD N Context. An increasing number of medical centers can collect bone marrow, peripheral blood, or umbilical cord stem cells. Pathology laboratories should accommodate this trend, but investment in additional equipment may be impractical. Objectives. To compare CD34 + cell counting results by using 2 widely available flow cytometry systems, with and without the use of a separate hematology analyzer (ie, single-platform versus dual-platform methodologies). Design. Whole blood and peripheral blood stem cell (PBSC) samples were analyzed from 13 healthy allogeneic PBSC donors and 46 autologous PBSC donors with various malignancies. The Cytomics FC500 (Beckman Coulter, The success of bone marrow or peripheral blood stem cell (PBSC) transplants is associated not only with phenotypic compatibility between donor and patient but also with the number of CD34 + white cells in the graft, relative to body weight or surface area of the recipient. 1 3 Flow cytometry is the method of choice to assess CD34 + cell content but protocols vary among institutions. 4 6 Moreover, CD34 expression is merely a surrogate measure of hematopoietic stem cell or progenitor cell content. Nevertheless, enumeration of CD34 + cells is an essential tool of PBSC harvest and for comparing different mobilization or collection schemes For successful enumeration of CD34 + cells, appropriate procedures are necessary to minimize pre-analytic, and postanalytic variables. Within the realm of analysis, the hardware and software of a flow cytometry system are responsible for collecting data on individual cells and aggregating that data into useful information. Thus, a system should be chosen that is appropriate to the task, and its operator(s) should be well versed in the nuances of its hardware, software, and the inputs (cells, antibodies, gating protocols, etc) that the hardware and software manipulate. Accepted for publication October 6, From the Department of Blood Transfusion and Transplantation Immunology, Fukushima Medical University, Fukushima City, Fukushima, Japan. The authors have no relevant financial interest in the products or companies described in this article. Reprints: Kenneth E. Nollet, MD, PhD, Department of Blood Transfusion and Transplantation Immunology, Fukushima Medical University, Hikarigaoka 1, Fukushima City, Fukushima , Japan ( nollet@fmu.ac.jp). Fullerton, California) was compared with the FACSCalibur (BD Biosciences, San Jose, California). Dual-platform CD34 + cell counting incorporated data from a KX-21 hematology analyzer (Sysmex, Kobe, Japan). Results. Subtle differences in CD34 + cell counting between 2 systems and 2 methods did not achieve statistical significance. Conclusion. Different systems and methods for CD34 + cell enumeration, properly validated, can support care for patients undergoing transplants and provide meaningful data for multicenter studies or meta-analyses. (Arch Pathol Lab Med. 2011;135: ) Single-platform methodologies, in which a known number of well-characterized fluorescent beads are added to the analyte, are intended to be more reliable and easier to use than dual-platform methods, which combine data from a conventional hematology analyzer and a flow cytometer. 11 Various platforms and methodologies have been compared, but prior results, regardless of outcome, should not discourage continued investigation and reporting of laboratory systems on which significant clinical outcomes depend. This article compares the Cytomics FC500 (Beckman Coulter, Fullerton, California) and the FACSCalibur (BD Biosciences, San Jose, California) flow cytometry systems, for the enumeration of CD34 + cells with both singleplatform and dual-platform methods. MATERIALS AND METHODS Research Subjects Participation of human research subjects conformed to institutional review board guidelines, applicable laws, and the World Medical Association Declaration of Helsinki. Sample Collection Samples were drawn from healthy allogeneic PBSC donors (n 5 13) and autologous PBSC patients (n 5 46) with malignant lymphoma (n 5 12), seminoma (n 5 9), multiple myeloma (n 5 8), rhabdomyosarcoma (n 5 4), neuroblastoma (n 5 3), and other conditions (n 5 10). Table 1 provides a demographic breakdown according to sample type. Peripheral blood stem cell (n 5 27) and whole blood (WB; n 5 32) samples were collected at a single institution from May 2005 through May 2009 and used for enumeration of CD34 + cells. Each WB sample was collected by venipuncture into an EDTA tube. Peripheral blood stem cell samples were collected by apheresis, Arch Pathol Lab Med Vol 135, July 2011 CD34 + Enumeration by Flow Cytometry Ngoma et al 909

2 Table 1. Demographic Characteristics Associated With 27 Peripheral Blood Stem Cell (PBSC) and 32 Whole Blood (WB) Samples Sample, type (No.) PBSC (27) WB (32) Age, median (range) 41.5 (1 65) 31 (1 62) Sex, male:female 13:14 13:19 Allogeneic PBSC donors, No. 6 7 Autologous PBSC patients, No Malignant lymphoma 6 6 Seminoma 4 5 Multiple myeloma 4 4 Rhabdomyosarcoma 1 3 Neuroblastoma 1 2 Amyloidosis 2 0 Ewing sarcoma 1 1 Wilms tumor 1 1 Ovarian cancer 1 1 Acute myeloid leukemia 0 1 Atherosclerosis obliterans 0 1 as described previously. 7,8 In all instances, sample collection immediately preceded sample preparation and analysis. Sample Preparation Freshly obtained WB and PBSC samples were used undiluted in experiments unless the white blood cell (WBC) count exceeded /mL. Samples with higher WBC concentrations were diluted to WBC/mL with phosphate-buffered saline. Immunofluorescence Staining, Cell Viability, and Erythrocyte Lysis Reagents Reagents (Stem-Kit, Beckman Coulter) for the Cytomics FC500 were as follows: phycoerythrin-conjugated anti-cd34 (CD34-PE, clone 581) and fluorescein isothiocyanate conjugated anti-cd45 (CD45-FITC, clone J33) for CD34 + WBC identification; PEconjugated isoclonic antibody combined with CD45-FITC (clone J33) as a control; 7-amino-actinomycin D (7-AAD) for cell viability assessment; ammonium chloride solution for erythrocyte lysis; and fluorescent bead reference standards of precisely known concentration (Stem-Count), for single-platform cell counting. Reagents (BD Biosciences) for the FACSCalibur were as follows: combined anti-cd45 and anti-cd34 (CD45-FITC/ CD34-PE, clones 2D1 and 8G12) for CD34 + WBC identification; 7-AAD for cell viability assessment; ammonium chloride solution (PharmLyse) for erythrocyte lysis; and test tubes preloaded with a precisely known quantity of lyophilized fluorescent bead reference standards (TruCount). Single-Platform Method Each manufacturer s procedure included red cell lysis without washing. 5,11 To assess white cell viability, 20 ml of 7-AAD was added to all tubes before any other reagents. For the Cytomics FC500, 20 ml of CD45-FITC/CD34-PE and 20 ml of control reagent were pipetted into different tubes and 100- ml samples were added to each tube. After 20 minutes of room temperature incubation in the dark, red cell lysis was initiated with 2 ml of buffered ammonium chloride (made fresh from 103 stock), followed by 8 to 10 minutes of incubation, without washing. Just before flow cytometry, 100 ml of Stem-Count fluorospheres was added and thoroughly mixed with the analyte. For the FACSCalibur, 20 ml of CD45-FITC/CD34-PE was pipetted into TruCount tubes, to which 50 ml ofsamplewas added. After 15 minutes of room-temperature incubation in the dark, red cell lysis was initiated with 1 ml of ammonium chloride, followed by 3 to 5 minutes of incubation before flow cytometry. Both instruments allowed absolute CD34 + cell enumeration when using the known fluorescent bead standards incorporated into each sample. A total of CD45 + events were collected per tube in both the Cytomics FC500 and the FACSCalibur; Figure 1 illustrates subsequent analysis with Cytomics software. Quantitation of viable CD34 + cells followed manufacturers instructions. For the Cytomics FC500: CD34 z cells per ml~ 2 3 number of cells in the CD34 z fraction of the analyte 6 { ðnumber of cells in the CD34 z fraction of the 7 4 negative control sample 5 ðtotal number of fluorescent beads in each tubeþ ðdilution factorþ= ðnumber of beads countedþ: For the FACSCalibur: CD34 z cells per ml~ ðnumber of cells in CD34 z fraction=number of beads countedþ ðtotal number of beads in each bead-coated tubeþ ðdilution factorþ: Nonviable cells, as determined by 7-AAD infiltration, were excluded, as illustrated in Figure 1, histogram 8. Viability was % for WB and % for PBSCs with the Cytomics FC500 and % for WB and % for PBSCs with the FACSCalibur. Dual-Platform Method In this approach, the fraction of CD34 + cells was obtained by flow cytometry, and absolute nucleated cell count was derived from a KX-21 automated hematology analyzer (Sysmex, Kobe, Japan). Percentage of CD34 + cells was determined by using double-color immunofluorescence staining (CD45-FITC/CD34- PE). Absolute number of CD34 + cells was obtained by the product of the CD34 + cells fraction and the nucleated cell count. Gating Strategies and Data Analysis Triple fluorophore gating was set up according to the International Society of Hematotherapy and Graft Engineering (ISHAGE) guidelines. 15 Briefly, CD34 +, 7-AAD 2, CD45 dim cells with low side scatter fraction were defined as CD34 + cells in hematopoietic stem cell/hematopoietic progenitor cell fractions (Figure 1, histogram 4). Statistical Analysis SPSS for Windows 16.0 (SPSS, Chicago, Illinois) was used for statistical analysis. Regression analysis was used to correlate results obtained by the 2 systems. Results are expressed as median (range). Statistical significance (P,.05) was determined with the nonparametric Wilcoxon test. RESULTS CD34 + Counts, Single-Platform Method The number of CD34 + cells detected was slightly higher with the Cytomics FC500 than with the FACSCalibur for both WB (median, 31.0/mL [range, /mL] versus median, 29.8/mL [ /mL]) and PBSCs (median, 1040/mL [range, /mL] versus median, 857.9/ ml [range, /mL]). These differences did not achieve statistical significance (Table 2). CD34 + Counts, Dual-Platform Method Differences in CD34 + cells detected with the Cytomics FC500 and with the FACSCalibur for WB (median, 31.0/ ml [range, /mL] versus median, 30.4/mL [range, 910 Arch Pathol Lab Med Vol 135, July 2011 CD34 + Enumeration by Flow Cytometry Ngoma et al

3 Figure 1. Flow cytometric analysis of a fresh peripheral blood stem cell sample analyzed on the Cytomics FC500 with Stem-Kit reagents (Beckman Coulter). Histogram 1, region A includes viable CD45+ leukocytes (excluding dead 7-AAD+ cells per histogram 8, region I); region E (lower right oval) is a lymphocyte-specific gate. Histogram 2 plots events from A and J; CD34+ cells are gated in B (polygon). Histogram 3, region C (polygon) gates CD34+, CD45+ cells from A, B, and J. Histogram 4, region D (lower right polygon) plots events sequentially gated from J, A, B, and C. Histogram 5 plots CD45 versus CD34 for all events. Histogram 6, region F (lower right polygon) shows live lymphocytes, from E and J. Histogram 7, region H tracks single StemCount beads for single-platform cell quantification. Histogram 8, as previously described, gates cell viability according to 7-AAD fluorescence. Abbreviations: CD45-FITC, fluorescein isothiocyanate-conjugated anti-cd45; CD34-PE, phycoerythrin-conjugated anti-cd34; FS, forward scatter; SS, side scatter; 7-AAD, 7-amino-actinomycin D /mL]) and PBSCs (median, 906.7/mL [range, /mL] versus 912.3/mL [range, /mL]) were not statistically significant (Table 3). Assessment of Single-Platform and Dual-Platform Measurements No statistically significant differences were observed between the number of CD34+ cells when using either Arch Pathol Lab Med Vol 135, July 2011 single-platform or dual-platform methods, regardless of the cytometer (Tables 4 and 5). CD34+ cell fraction (%) correlated well by linear regression when comparing FACSCalibur and Cytomics FC500 data for both WB (r ) and PBSCs (r ), as shown in Figures 2 and 3, respectively. Similarly, CD34+ absolute counts correlated well when comparing single-platform and dual-platform analysis of CD34+ Enumeration by Flow Cytometry Ngoma et al 911

4 Table 2. CD34 + Cell Quantitation of 27 Peripheral Blood Stem Cell (PBSC) and 32 Whole Blood (WB) Samples With Single-Platform Methodology (Cytomics FC500 Versus FACSCalibur) Cytomics FC500 FACSCalibur P Value WB, median (range), ml ( ) 29.8 ( ).88 PBSC, median (range), ml ( ) 857 ( ).72 WB with the FACSCalibur (r , Figure 4), WB with the Cytomics FC500 (r , Figure 5), PBSCs with the FACSCalibur (r , Figure 6), and PBSCs with the Cytomics FC500 (r , Figure 7). Error Analysis Surveillance for preanalytic variables included a comparison of results from 1 senior operator processing the same sample 4 times versus 4 operators individually processing the same sample. For this purpose, WB was diluted by a factor of 4 and PBSCs were diluted by a factor of 30. Single-operator results were not statistically different from results aggregated from 4 operators (data not shown). COMMENT It is now well established that engraftment success correlates with CD34 + cell count, independent of the degree of phenotypic similarity between donors and recipients. We owe this insight to the development of accurate cell counting methodologies, which are useful not only for individual patients but also for aggregating treatment and outcome data from many facilities. Flow cytometric quantification of CD34 + cells is now the most widely used tool to optimize mobilization and harvest of hematopoietic progenitor/stem cells for PBSC or bone marrow transplant. 14 The first flow cytometric gold standard for the care of patients undergoing transplants was, in fact, a synthesis of data from 2 antecedent gold standards: the hematology analyzer for absolute leukocyte counting and the flow cytometer for the relative proportion of progenitor cells, as estimated by a surrogate marker such as CD34. Since the emergence of single-platform flow cytometric measurements, the original dual-platform standard has been criticized for being labor-intensive. Furthermore, historical data have linked the use of hematology analyzers to high coefficients of variation in CD4 + T-lymphocyte enumeration. 16 Thus, the motivation for developing single-platform methods, using beads or volumetric techniques to generate absolute cell counts, is well founded. 17,18 Keeney et al 11 adapted ISHAGE dual-platform guidelines for single-platform use, with favorable results. Several studies 19,20 have demonstrated that the single-platform approach achieves the highest possible reliability to quantify viable CD34 + cells, owing to reduced intralaboratory and interlaboratory variation. Therefore, this approach has been included in a variety of national 21 and international 6 guidelines and a number of laboratory technical manuals. 22,23 Nevertheless, CD34 + counting methodologies have not been exhaustively studied across the range of systems that are likely to be found in modern clinical pathology laboratories. To this end, we have compared the Cytomics FC500 and FACSCalibur, using both single-platform and dual-platform methodologies. Statistically significant differences would most likely cast single-platform methods in the most favorable light, whereas statistically insignificant differences would offer some reassurance that data from a wider variety of laboratories might be intelligently assimilated and analyzed. Differences between platforms and methodologies in our laboratory did not achieve statistical significance. This is in accordance with Sutherland et al, 14 who recently compared the CD34 + cell numbers derived from Stem-Kit and TruCount systems and found that the 2 kits generated very similar data on a range of fresh samples with FACSCalibur and FACSCanto instruments (both, BD Biosciences). In contrast, we report single-platform and dual-platform methodologies with 2 instruments from 2 different manufacturers. Linear Table 3. CD34 + Cell Quantitation of 27 Peripheral Blood Stem Cell (PBSC) and 32 Whole Blood (WB) Samples With Dual-Platform Methodology (Cytomics FC500 Versus FACSCalibur) Cytomics FC500 FACSCalibur P Value WB, median (range), ml ( ) 30.4 ( ).99 PBSC, median (range), ml ( ) ( ).99 Table 4. CD34 + Cell Quantitation of 27 Peripheral Blood Stem Cell (PBSC) and 32 Whole Blood (WB) Samples With the Cytomics FC500 (Single-Platform Versus Dual-Platform Methodology) Single Platform Dual Platform P Value WB, median (range), ml ( ) 31 ( ).91 PBSC, median (range), ml ( ) ( ).73 Table 5. CD34 + Cell Quantitation of 27 Peripheral Blood Stem Cell (PBSC) and 32 Whole Blood (WB) Samples With the FACSCalibur (Single-Platform Versus Dual-Platform Methodology) Single Platform Dual Platform P Value WB, median (range), ml ( ) 30.4 ( ).98 PBSC, median (range), ml ( ) ( ) Arch Pathol Lab Med Vol 135, July 2011 CD34 + Enumeration by Flow Cytometry Ngoma et al

5 Figure 2. Figure 3. Figure 4. Figure 5. Figure 6. Figure 7. Correlation of CD34 + cell fraction (%) in 32 whole blood samples: FACSCalibur versus Cytomics FC500. Correlation of CD34 + cell fraction (%) in 27 peripheral blood stem cell samples: FACSCalibur versus Cytomics FC500. Correlation of CD34 + cell counts in 32 whole blood samples: single-platform versus dual-platform, FACSCalibur. Correlation of CD34 + cell counts in 32 whole blood samples: single-platform versus dual-platform, Cytomics FC500. Correlation of CD34 + cell counts in 27 peripheral blood stem cell samples: single-platform versus dual-platform, FACSCalibur. Correlation of CD34 + cell counts in 27 peripheral blood stem cell samples: single-platform versus dual-platform, Cytomics FC500. regression analysis of our data yielded high correlation coefficients when comparing Cytomics FC500 and FACS- Calibur CD34 + fractions, and single-platform versus dualplatform absolute CD34 + counts on either instrument (Figures 2 through 7). It can be argued that laboratories routinely using a single-platform method should be confident of alternative methods, not only for quality assurance but also for reliable patient care in the event that properly stored, in-date calibration beads are unavailable. Preliminary assessment Arch Pathol Lab Med Vol 135, July 2011 CD34 + Enumeration by Flow Cytometry Ngoma et al 913

6 of interoperator performance on replicate samples has been favorable in our laboratory but needs to be formalized as an ongoing assessment of intralaboratory variation for singleplatform and dual-platform methods; we would welcome the opportunity to cooperate with other institutions to quantify interlaboratory variations. Altogether, these observations suggest that differences among flow cytometry systems need not deter laboratories from participating in local and multicenter transplant efforts. Multicenter investigations might corroborate this, or, alternatively, shed light on some as-yet unaccounted variables. As our laboratory only provides support for PBSC transplant, it would be instructive to know whether centers supporting bone marrow and/or cord blood transplant would reach similar conclusions as ours. Negative results in regard to differences among systems, methods, and laboratories would in fact be a positive outcome, indicating that consistent enumeration of CD34 + cells is achievable among laboratories. References 1. Fritsch G, Stimpfl M, Kurz M, et al. Characterization of hematopoietic stem cells. Ann N Y Acad Sci. 1995;770: Fritsch G, Stimpfl M, Kurz M, et al. The composition of CD34 subpopulations differs between bone marrow, blood and cord blood. Bone Marrow Transplant. 1996;17(2): Allan DS, Keeney M, Howson-Jan K, et al. Number of viable CD34(+) cells reinfused predicts engraftment in autologous hematopoietic stem cell transplantation. Bone Marrow Transplant. 2002;29(12): Chin-Yee I, Anderson L, Keeney M, Sutherland DR. Quality assurance of stem cell enumeration by flow cytometry; Canadian QASE Study Group. Cytometry. 1997;30(6): Fritsch G, Printz D, Stimpfl M, et al. Quantification of CD34 + cells: comparison of methods. Transfusion. 1997;37(8): Gratama JW, Orfao A, Barnett D, et al. Flow cytometric enumeration of CD34 + hematopoietic stem and progenitor cells; European Working Group on Clinical Cell Analysis. Cytometry. 1998;34(3): Ikeda K, Ohto H, Kanno T, et al. Automated programs for collection of mononuclear cells and progenitor cells by two separators for peripheral blood progenitor cell transplantation: comparison by a randomized crossover study. Transfusion. 2007;47(7): Ikeda K, Ohto H, Nemoto K, et al. Collection of MNCs and progenitor cells by two separators for PBPC transplantation: a randomized crossover trial. Transfusion. 2003;43(6): Kessinger A, Sharp JG. Mobilization of blood stem cells. Stem Cells. 1998; 16(suppl 1): Kessinger A, Sharp JG. The whys and hows of hematopoietic progenitor and stem cell mobilization. Bone Marrow Transplant. 2003; 31(5): Keeney M, Chin-Yee I, Weir K, Popma J, Nayar R, Sutherland DR. Single platform flow cytometric absolute CD34 + cell counts based on the ISHAGE guidelines; International Society of Hematotherapy and Graft Engineering. Cytometry. 1998;34(2): Barbosa IL, Sousa ME, Godinho MI, Sousa F, Carvalhais A. Single- versus dual-platform assays for human CD34 + cell enumeration. Cytometry. 1999;38(6): Gajkowska A, Oldak T, Jastrzewska M, et al. Flow cytometric enumeration of CD34 + hematopoietic stem and progenitor cells in leukapheresis product and bone marrow for clinical transplantation: a comparison of three methods. Folia Histochem Cytobiol. 2006;44(1): Sutherland DR, Nayyar R, Acton E, Giftakis A, Dean S, Mosiman VL. Comparison of two single-platform ISHAGE-based CD34 enumeration protocols on BD FACSCalibur and FACSCanto flow cytometers. Cytotherapy. 2009;11(5): Sutherland DR, Anderson L, Keeney M, Nayar R, Chin-Yee I. The ISHAGE guidelines for CD34 + cell determination by flow cytometry; International Society of Hematotherapy and Graft Engineering. J Hematother. 1996;5(3): Robinson G, Morgan L, Evans M, et al. Effect of type of haematology analyser on CD4 count. Lancet. 1992;340(8817): Mercolino TJ, Connelly MC, Meyer EJ, et al. Immunologic differentiation of absolute lymphocyte count with an integrated flow cytometric system: a new concept for absolute T cell subset determinations. Cytometry. 1995;22(1): Strauss K, Hannet I, Engels S, et al. Performance evaluation of the FACSCount System: a dedicated system for clinical cellular analysis. Cytometry. 1996;26(1): Barnett D, Granger V, Kraan J, et al. Reduction of intra- and interlaboratory variation in CD34 + stem cell enumeration using stable test material, standard protocols and targeted training; DK34 Task Force of the European Working Group of Clinical Cell Analysis (EWGCCA). Br J Haematol. 2000;108(4): Gratama JW, Kraan J, Keeney M, Sutherland DR, Granger V, Barnett D. Validation of the single-platform ISHAGE method for CD34(+) hematopoietic stem and progenitor cell enumeration in an international multicenter study. Cytotherapy. 2003;5(1): Barnett D, Janossy G, Lubenko A, Matutes E, Newland A, Reilly JT. Guideline for the flow cytometric enumeration of CD34 + haematopoietic stem cells: prepared by the CD34 + haematopoietic stem cell working party; General Haematology Task Force of the British Committee for Standards in Haematology. Clin Lab Haematol. 1999;21(5): Gratama JW, Kraan J, Keeney M, Mandy F, Sutherland DR, Wood BL. Enumeration of Immunologically Defined Cell Populations by Flow Cytometry; Approved Guideline. Vol 27 (16). 2nd ed. Wayne, Pennsylvania: Clinical and Laboratory Standards Institute; Sutherland DR, Keeney M, Gratama JW. Enumeration of CD34 + hematopoietic stem and progenitor cells. Curr Protoc Cytom. 2003;chapter 6:unit Arch Pathol Lab Med Vol 135, July 2011 CD34 + Enumeration by Flow Cytometry Ngoma et al

Analyzing Samples for CD34 Enumeration Using the BD Stem Cell Enumeration Kit

Analyzing Samples for CD34 Enumeration Using the BD Stem Cell Enumeration Kit 2 Analyzing Samples for CD34 Enumeration Using the BD Stem Cell Enumeration Kit Presented by Ellen Meinelt, MS MLS(ASCP) CM, Technical Applications Specialist and Calin Yuan, Product Course Developer,

More information

CD34 numeration through the French external quality control: Impact in the implementation of new technical chapters at the European Pharmacopoeia

CD34 numeration through the French external quality control: Impact in the implementation of new technical chapters at the European Pharmacopoeia CD34 numeration through the French external quality control: Impact in the implementation of new technical chapters at the European Pharmacopoeia Panterne Béatrice Cells and Tissues Coordinator Batch release

More information

Stepcount. Product Description: Closed transparent tubes with a metal screen, including a white matrix at the bottom. Cat. Reference: STP-25T

Stepcount. Product Description: Closed transparent tubes with a metal screen, including a white matrix at the bottom. Cat. Reference: STP-25T Product Description: Closed transparent tubes with a metal screen, including a white matrix at the bottom Cat. Reference: STP-25T Reagent provided:: 25 Stepcount tubes for 25 test INTENDED USE. Immunostep

More information

A. Gajkowska 1, T. Oldak 1,2, M. Jastrzewska 1, E.K. Machaj 1,2, J. Walewski 3, E. Kraszewska 4 and Z. Pojda 1,2. Introduction

A. Gajkowska 1, T. Oldak 1,2, M. Jastrzewska 1, E.K. Machaj 1,2, J. Walewski 3, E. Kraszewska 4 and Z. Pojda 1,2. Introduction FOLIA HISTOCHEMICA ET CYTOBIOLOGICA Vol. 44, No. 1, 2006 pp. 53-60 Flow cytometric enumeration of CD34 + hematopoietic stem and progenitor cells in leukapheresis product and bone marrow for clinical transplantation:

More information

Standardization, Calibration and Quality Control

Standardization, Calibration and Quality Control Standardization, Calibration and Quality Control Ian Storie Flow cytometry has become an essential tool in the research and clinical diagnostic laboratory. The range of available flow-based diagnostic

More information

Enumeration of CD34-positive hematopoietic progenitor cells by flow cytometry: comparison of a volumetric assay and the ISHAGE gating strategy

Enumeration of CD34-positive hematopoietic progenitor cells by flow cytometry: comparison of a volumetric assay and the ISHAGE gating strategy Bone Marrow Transplantation, (1998) 22, 699 76 1998 Stockton Press All rights reserved 268 3369/98 $12. http://www.stockton-press.co.uk/bmt Enumeration of CD34-positive hematopoietic progenitor cells by

More information

Absolute counting using flow cytometry. Bright Count Microspheres

Absolute counting using flow cytometry. Bright Count Microspheres Absolute counting using flow cytometry Single-platform system for absolute counts I PRODUCT MANUAL [REF] IQP-391 [REF] IQP-392 s 50 tests s 100 tests [IVD] In Vitro Diagnostic medical device IQ Products

More information

Flow cytometric analysis of stem cells derived from umbilical cord blood CD34+/CD45+ enumeration and viability

Flow cytometric analysis of stem cells derived from umbilical cord blood CD34+/CD45+ enumeration and viability Flow cytometric analysis of stem cells derived from umbilical cord blood CD34+/CD45+ enumeration and viability Doretha Thompson Dissertation in fulfillment of the requirements for the degree Magister Scientiae

More information

Enumeration and Viability of Nucleated Cells from Bone Marrow, Cord Blood, and Mobilized Peripheral Blood

Enumeration and Viability of Nucleated Cells from Bone Marrow, Cord Blood, and Mobilized Peripheral Blood Application Note Primary Cell Analysis Enumeration and Viability of Nucleated Cells from Bone Marrow, Cord Blood, and Mobilized Peripheral Blood Cell Viability Introduction: Bone Marrow, Cord Blood, Stem

More information

No-wash, no-lyse detection of leukocytes in human whole blood on the Attune NxT Flow Cytometer

No-wash, no-lyse detection of leukocytes in human whole blood on the Attune NxT Flow Cytometer APPLICATION NOTE Attune NxT Flow Cytometer No-wash, no-lyse detection of leukocytes in human whole blood on the Attune NxT Flow Cytometer Introduction Standard methods for isolating and detecting leukocytes

More information

Fresh PBSC harvests, but not BM, show temperature-related loss of CD34 viability during storage and transport

Fresh PBSC harvests, but not BM, show temperature-related loss of CD34 viability during storage and transport Cytotherapy (2006) Vol. 8, No. 2, 158/165 Fresh PBSC harvests, but not BM, show temperature-related loss of CD34 viability during storage and transport V Antonenas 1, F Garvin 1, M Webb 1, M Sartor 2,

More information

APPLICATION INFORMATION

APPLICATION INFORMATION DRAFT: Rev. D A-2045A APPLICATION INFORMATION Flow Cytometry 3-COLOR COMPENSATION Raquel Cabana,* Mark Cheetham, Jay Enten, Yong Song, Michael Thomas,* and Brendan S. Yee Beckman Coulter, Inc., Miami FL

More information

2. SUMMARY AND EXPLANATION

2. SUMMARY AND EXPLANATION M3630IV_C 2003-09-01 1 / 29 English Stem-Kit Reagents 1-29 1. INTENDED USE 2 2. SUMMARY AND EXPLANATION 2 3. PRINCIPLE OF TEST 3 4. CLINICAL RELEVANCE 3 5. REAGENTS AND CONTENTS 3 6. STATEMENT OF WARNING

More information

WHOLE BLOOD LYSING SOLUTION FOR FLOW CYTOMETRIC APPLICATIONS

WHOLE BLOOD LYSING SOLUTION FOR FLOW CYTOMETRIC APPLICATIONS FOR IN-VITRO DIAGNOSTIC USE INVITROGEN CAL-LYSE TM Lysing Solution WHOLE BLOOD LYSING SOLUTION FOR FLOW CYTOMETRIC APPLICATIONS CAL-LYSE TM CATALOG No. GAS-010 250 tests 25 ml CATALOG No. GAS-010S-100

More information

Direct measurement of CD34+ cord blood stem cell absolute counts, viability and WBC using flow cytometry

Direct measurement of CD34+ cord blood stem cell absolute counts, viability and WBC using flow cytometry Original Article Direct measurement of CD34+ cord blood stem cell absolute counts, viability and WBC using flow cytometry Vasiliki e. Kalodimou 1, Lefteris Bikos 2, Calliope Kourenti 3, Aikaterini Fifa

More information

Immunophenotyping peripheral blood cells

Immunophenotyping peripheral blood cells IMMUNOPHENOTYPING Attune Accoustic Focusing Cytometer Immunophenotyping peripheral blood cells A no-lyse, no-wash, no cell loss method for immunophenotyping nucleated peripheral blood cells using the Attune

More information

Minimal residual disease detection in Acute Myeloid Leukaemia on a Becton Dickinson flow cytometer

Minimal residual disease detection in Acute Myeloid Leukaemia on a Becton Dickinson flow cytometer Minimal residual disease detection in Acute Myeloid Leukaemia on a Becton Dickinson flow cytometer Purpose This procedure gives instruction on minimal residual disease (MRD) detection in patients with

More information

Flow Cytometry for Everyone Else Susan McQuiston, J.D., MLS(ASCP), C.Cy.

Flow Cytometry for Everyone Else Susan McQuiston, J.D., MLS(ASCP), C.Cy. Flow Cytometry for Everyone Else Susan McQuiston, J.D., MLS(ASCP), C.Cy. At the end of this session, the participant will be able to: 1. Describe the components of a flow cytometer 2. Describe the gating

More information

Utility of flow cytometric κ and λ light chain analysis of peripheral blood

Utility of flow cytometric κ and λ light chain analysis of peripheral blood JBUON 2015; 20(5): 1322-1326 ISSN: 1107-0625, online ISSN: 2241-6293 www.jbuon.com E-mail: editorial_office@jbuon.com ORIGINAL ARTICLE Utility of flow cytometric κ and λ light chain analysis of peripheral

More information

Low Cost CD4 Enumeration Using Generic Monoclonal Antibody Reagents and a Two-Color User-Defined MultiSET TM Protocol

Low Cost CD4 Enumeration Using Generic Monoclonal Antibody Reagents and a Two-Color User-Defined MultiSET TM Protocol Cytometry Part B (Clinical Cytometry) 70B:355 360 (2006) Low Cost CD4 Enumeration Using Generic Monoclonal Antibody Reagents and a Two-Color User-Defined MultiSET TM Protocol Kovit Pattanapanyasat, 1 *

More information

Technical report High-efficiency volume reduction of cord blood using pentastarch

Technical report High-efficiency volume reduction of cord blood using pentastarch (2001) 27, 457 461 2001 Nature Publishing Group All rights reserved 0268 3369/01 $15.00 www.nature.com/bmt Technical report High-efficiency volume reduction of cord blood using pentastarch H Yang 1,2,

More information

Multicolor Bead Flow Cytometry Standardization Heba Degheidy MD, PhD, QCYM DB/OSEL/CDRH/FDA Manager of MCM Flow Cytometry Facility

Multicolor Bead Flow Cytometry Standardization Heba Degheidy MD, PhD, QCYM DB/OSEL/CDRH/FDA Manager of MCM Flow Cytometry Facility Multicolor Bead Flow Cytometry Standardization Heba Degheidy MD, PhD, QCYM DB/OSEL/CDRH/FDA Manager of MCM Flow Cytometry Facility The mention of commercial products, their sources, or their use in connection

More information

TITLE: TRU-COUNT ENUMERATION OF T-CELLS IN WHOLE

TITLE: TRU-COUNT ENUMERATION OF T-CELLS IN WHOLE TITLE: TRU-COUNT ENUMERATION OF T-CELLS IN WHOLE PRINCIPLES OF THE PROCEDURE: When whole blood is added to the reagent, the fluorochrome labeled antibodies in the reagent bind specifically to leukocyte

More information

123count ebeads Catalog Number: 01-1234 Also known as: Absolute cell count beads GPR: General Purpose Reagents. For Laboratory Use.

123count ebeads Catalog Number: 01-1234 Also known as: Absolute cell count beads GPR: General Purpose Reagents. For Laboratory Use. Page 1 of 1 Catalog Number: 01-1234 Also known as: Absolute cell count beads GPR: General Purpose Reagents. For Laboratory Use. Normal human peripheral blood was stained with Anti- Human CD45 PE (cat.

More information

Improved Ex Vivo Expansion of Functional CD34 + Cells Using Stemline II Hematopoietic Stem Cell Expansion Medium

Improved Ex Vivo Expansion of Functional CD34 + Cells Using Stemline II Hematopoietic Stem Cell Expansion Medium Improved Ex Vivo Expansion of Functional CD34 + Cells Using Stemline II Hematopoietic Stem Cell Expansion Medium Daniel W. Allison, 1 Stacy L. Leugers, 1 Barry J. Pronold, 2 Gary Van Zant, 2 Jenny A. Harrington,

More information

BD Trucount Tubes IVD

BD Trucount Tubes IVD 02/2015 23-3483-07 IVD BD Trucount Tubes For determining absolute counts of leucocytes in blood 25 Tubes Catalog No. 340334 BD, BD Logo and all other trademarks are property of Becton, Dickinson and Company.

More information

Cord Blood for Cellular Therapy: A Snapshot of this Evolving Market Landscape

Cord Blood for Cellular Therapy: A Snapshot of this Evolving Market Landscape GENReports: Market & Tech Analysis Cord Blood for Cellular Therapy: A Snapshot of this Evolving Market Landscape > Enal Razvi, Ph.D. Biotechnology Analyst, Managing Director SELECTBIO US enal@selectbio.us

More information

Whole Blood Flow Cytometry

Whole Blood Flow Cytometry Whole Blood Flow Cytometry y Nailin Li Department t of Medicine, i Clinical i l Pharmacology Unit Karolinska Institute/University Hospital, 171 76 Stockholm Department of Pathology & Pathophysiology Zhejiang

More information

AUTOMATION OF THE COLONY-FORMING CELL ASSAY FOR MEASURING HEMATOPOIETIC PROGENITORS IN CORD BLOOD

AUTOMATION OF THE COLONY-FORMING CELL ASSAY FOR MEASURING HEMATOPOIETIC PROGENITORS IN CORD BLOOD AUTOMATION OF THE COLONY-FORMING CELL ASSAY FOR MEASURING HEMATOPOIETIC PROGENITORS IN CORD BLOOD Bert Wognum Oliver Egeler Caren Grande Ning Yuan Steven Woodside Terry Thomas Allen Eaves STEMCELL Technologies

More information

Potency Assays for an Autologous Active Immunotherapy (Sipuleucel-T) Pocheng Liu, Ph.D. Senior Scientist of Product Development Dendreon Corporation

Potency Assays for an Autologous Active Immunotherapy (Sipuleucel-T) Pocheng Liu, Ph.D. Senior Scientist of Product Development Dendreon Corporation Potency Assays for an Autologous Active Immunotherapy (Sipuleucel-T) Pocheng Liu, Ph.D. Senior Scientist of Product Development Dendreon Corporation Sipuleucel-T Manufacturing Process Day 1 Leukapheresis

More information

Stem Cell Transplantation

Stem Cell Transplantation Harmony Behavioral Health, Inc. Harmony Behavioral Health of Florida, Inc. Harmony Health Plan of Illinois, Inc. HealthEase of Florida, Inc. Ohana Health Plan, a plan offered by WellCare Health Insurance

More information

Application Note 10. Measurement of Cell Recovery. After Sorting with a Catcher-Tube-Based. Cell Sorter. Introduction

Application Note 10. Measurement of Cell Recovery. After Sorting with a Catcher-Tube-Based. Cell Sorter. Introduction Application Note 10 Measurement of Cell Recovery After Sorting with a Catcher-Tube-Based Cell Sorter Introduction In many experiments using sorted cells, it is important to be able to count the number

More information

The NIAID Flow Cytometry Advisory Committee; the Guidelines Subcommittee

The NIAID Flow Cytometry Advisory Committee; the Guidelines Subcommittee January, 1999 From: To: Subject: The NIAID Flow Cytometry Advisory Committee; the Guidelines Subcommittee NIAID DAIDS Flow Cytometry Laboratories Comparison study information for labs wishing to switch

More information

14.0 Stem Cell Laboratory Services

14.0 Stem Cell Laboratory Services Laboratory Services Contact Information: To inquire about assisting with surgical harvesting of bone marrow, cellular therapy (CT) product processing, cryopreservation, storage, or any other lab services,

More information

Narrator: Transplants using stem cells from the blood, bone marrow or umbilical cord blood

Narrator: Transplants using stem cells from the blood, bone marrow or umbilical cord blood [Track 2: What Is a Transplant?] Narrator: Transplants using stem cells from the blood, bone marrow or umbilical cord blood can be an effective treatment for people with blood cancers such as leukemia,

More information

CyTOF2. Mass cytometry system. Unveil new cell types and function with high-parameter protein detection

CyTOF2. Mass cytometry system. Unveil new cell types and function with high-parameter protein detection CyTOF2 Mass cytometry system Unveil new cell types and function with high-parameter protein detection DISCOVER MORE. IMAGINE MORE. MASS CYTOMETRY. THE FUTURE OF CYTOMETRY TODAY. Mass cytometry resolves

More information

CD34+ CELL ENUMERATION ON FROZEN SAMPLES: VIABILITY ASSESSMENT

CD34+ CELL ENUMERATION ON FROZEN SAMPLES: VIABILITY ASSESSMENT CD34+ CELL ENUMERATION ON FROZEN SAMPLES: VIABILITY ASSESSMENT Stradivari Antonio Francesco Lanza Hematology Institute- Cremona Italy ------------ EBMT STWP Chairman ----------- ISTANBUL, EBMT 215 1 CELL

More information

Guideline for the flow cytometric enumeration of CD34 + haematopoietic stem cells

Guideline for the flow cytometric enumeration of CD34 + haematopoietic stem cells Clin. Lab. Haem. 1999, 21, 301 308 Guideline for the flow cytometric enumeration of CD34 + haematopoietic stem cells PREPARED BY THE CD34 + HAEMATOPOIETIC STEM CELL WORKING PARTY* *D. Barnett, G. Janossy,

More information

Bone Marrow Transplantation and Peripheral Blood Stem Cell Transplantation: Questions and Answers. Key Points

Bone Marrow Transplantation and Peripheral Blood Stem Cell Transplantation: Questions and Answers. Key Points CANCER FACTS N a t i o n a l C a n c e r I n s t i t u t e N a t i o n a l I n s t i t u t e s o f H e a l t h D e p a r t m e n t o f H e a l t h a n d H u m a n S e r v i c e s Bone Marrow Transplantation

More information

低 剂 量 辐 射 对 脐 血 T 淋 巴 细 胞 膜 分 子 表 达 的 影 响 EFFECT OF LOW DOSE IRRADIATION ON EXPRESSION OF MEMBRANE MOLECULES OF T LYMPHOCYTES IN CORD BLOOD

低 剂 量 辐 射 对 脐 血 T 淋 巴 细 胞 膜 分 子 表 达 的 影 响 EFFECT OF LOW DOSE IRRADIATION ON EXPRESSION OF MEMBRANE MOLECULES OF T LYMPHOCYTES IN CORD BLOOD CNIC-01513 PUTH-0001 低 剂 量 辐 射 对 脐 血 T 淋 巴 细 胞 膜 分 子 表 达 的 影 响 EFFECT OF LOW DOSE IRRADIATION ON EXPRESSION OF MEMBRANE MOLECULES OF T LYMPHOCYTES IN CORD BLOOD 中 国 核 情 报 中 心 China Nuclear Information

More information

Recommendations to Transplant Centres Performing Cord Blood Transplants. Why Choosing the Right Thaw Method Could Save a Patient s Life

Recommendations to Transplant Centres Performing Cord Blood Transplants. Why Choosing the Right Thaw Method Could Save a Patient s Life Recommendations to Transplant Centres Performing Cord Blood Transplants Vicki Antonenas Why Choosing the Right Thaw Method Could Save a Patient s Life Lynn O Donnell (USA) 1 The process of receiving, testing

More information

Standard Operating Procedure

Standard Operating Procedure 1.0 Purpose: 1.1 The characterisation of of main leukocyte subsets in peripheral blood cells from mice by flow cytometry. Reliable values of frequencies of leukocyte clusters are very much dependent on

More information

Corporate Medical Policy Cord Blood as a Source of Stem Cells

Corporate Medical Policy Cord Blood as a Source of Stem Cells Corporate Medical Policy Cord Blood as a Source of Stem Cells File Name: Origination: Last CAP Review: Next CAP Review: Last Review cord_blood_as_a_source_of_stem_cells 2/2001 3/2015 3/2016 3/2015 Description

More information

Blood-Forming Stem Cell Transplants

Blood-Forming Stem Cell Transplants Blood-Forming Stem Cell Transplants What are bone marrow and hematopoietic stem cells? Bone marrow is the soft, sponge-like material found inside bones. It contains immature cells known as hematopoietic

More information

Subtypes of AML follow branches of myeloid development, making the FAB classificaoon relaovely simple to understand.

Subtypes of AML follow branches of myeloid development, making the FAB classificaoon relaovely simple to understand. 1 2 3 4 The FAB assigns a cut off of 30% blasts to define AML and relies predominantly on morphology and cytochemical stains (MPO, Sudan Black, and NSE which will be discussed later). Subtypes of AML follow

More information

CPT Codes for Bone Marrow Transplant January 2015 James L. Gajewski, MD

CPT Codes for Bone Marrow Transplant January 2015 James L. Gajewski, MD The blood and marrow transplant field has 15 dedicated CPT codes. These CPT codes can be categorized into three groups: 1. Collection Codes 2. Cell Processing Codes 3. Cell Infusion Codes Collection Codes

More information

Transmedcon 2014. Ahmedabad, Gujarat November 14-16, 2014

Transmedcon 2014. Ahmedabad, Gujarat November 14-16, 2014 FACT Accreditation for Cord Blood Banks and Cellular Therapy Nadim Mahmud, MD, PhD Associate Professor of Medicine Division of Hematology/Oncology Director, Hospital Stem Cell Laboratory Blood & Marrow

More information

Fetal Maternal Immunity and Antileukemia Activity in Cord Blood Transplant. Recipients

Fetal Maternal Immunity and Antileukemia Activity in Cord Blood Transplant. Recipients Fetal Maternal Immunity and Antileukemia Activity in Cord Blood Transplant Recipients Filippo Milano, 1 J. Lee Nelson, 1, 2 Colleen Delaney 1,3 1 Clinical Research Division, Fred Hutchinson Cancer Research

More information

Spherotech, Inc. 27845 Irma Lee Circle, Unit 101, Lake Forest, Illinois 60045 1

Spherotech, Inc. 27845 Irma Lee Circle, Unit 101, Lake Forest, Illinois 60045 1 78 Irma Lee Circle, Unit 0, Lake Forest, Illinois 00 SPHERO TM Technical Note STN- Rev B 008 DETERMINING PMT LINEARITY IN FLOW CYTOMETERS USING THE SPHERO TM PMT QUALITY CONTROL EXCEL TEMPLATE Introduction

More information

One of the most important recent developments in cancer treatment has been the ability to harvest stem

One of the most important recent developments in cancer treatment has been the ability to harvest stem BIOTECHNOLOGY A Patient-Friendly Approach to Human Cell Transplantation One of the most important recent developments in cancer treatment has been the ability to harvest stem cells from bone marrow or

More information

Haematopoietic Chimerism Analysis after Allogeneic Stem Cell Transplantation

Haematopoietic Chimerism Analysis after Allogeneic Stem Cell Transplantation Haematopoietic Chimerism Analysis after Allogeneic Stem Cell Transplantation Dr Ros Ganderton, Ms Kate Parratt, Dr Debbie Richardson, Dr Kim Orchard and Dr Liz Hodges Departments of Molecular Pathology

More information

Application Note. Multiparametric Immunophenotyping of Human Hematopoietic Stem Cells and Progenitor Cells by Flow Cytometry.

Application Note. Multiparametric Immunophenotyping of Human Hematopoietic Stem Cells and Progenitor Cells by Flow Cytometry. January 212 Multiparametric Immunophenotyping of Human Hematopoietic Stem Cells and Progenitor Cells by Flow Cytometry Xiaoyang (Alice) Wang, Janelle Shook, Mark Edinger, Noel Warner, Charlene Bush-Donovan

More information

Immunophenotyping. Alberto Orfao, MD, PhD

Immunophenotyping. Alberto Orfao, MD, PhD Immunophenotyping Alberto Orfao, MD, PhD Introduction Immunophenotyping of biological samples refers to the use of immunological tools (e.g. monoclonal and/or polyclonal antibodies) for the specific detection

More information

RPCI 004 v.002 Staining Procedure For all Directly Conjugated Reagents (Whole Blood Method)

RPCI 004 v.002 Staining Procedure For all Directly Conjugated Reagents (Whole Blood Method) Immune Tolerance Network RPCI 004 v.002 Staining Procedure For all Directly Conjugated Reagents (Whole Blood Method) Author: Paul Wallace, Director, RPCI Laboratory of Flow Cytometry Approved by: Paul

More information

JOINT COMMISSION INTERNATIONAL ACCREDITATION STANDARDS FOR. 2nd Edition

JOINT COMMISSION INTERNATIONAL ACCREDITATION STANDARDS FOR. 2nd Edition JOINT COMMISSION INTERNATIONAL ACCREDITATION STANDARDS FOR CliniCAl laboratories 2nd Edition Effective 1 April 2010 International Patient Safety Goals (IPSG) Goals The following is a list of all goals.

More information

Notes on titering antibodies

Notes on titering antibodies Home Events This Week Bulletin Boards Lab Personnel Lab Policies Protocols MolBio Tetramers Proteins Flow Cytometry Immunoassays Instruments Computers Lab Publications Scientiific Literature Science on

More information

CD34 Enumeration in the Clinical Laboratory Learning Objectives Contents

CD34 Enumeration in the Clinical Laboratory Learning Objectives Contents CD34 Enumeration in the Clinical Laboratory Vera S. Donnenberg, Ph.D., Assistant Professor of Surgery Deborah L. Griffin, M.S., Manager QA Cellular Therapies Learning Objectives To understand and perform

More information

Application Information Bulletin: Set-Up of the CytoFLEX Set-Up of the CytoFLEX* for Extracellular Vesicle Measurement

Application Information Bulletin: Set-Up of the CytoFLEX Set-Up of the CytoFLEX* for Extracellular Vesicle Measurement Application Information Bulletin: Set-Up of the CytoFLEX Set-Up of the CytoFLEX* for Extracellular Vesicle Measurement Andreas Spittler, MD, Associate Professor for Pathophysiology, Medical University

More information

flow cytometry reinvented

flow cytometry reinvented FLOW CYTOMETRY flow cytometry reinvented The Attune Acoustic Focusing Cytometer Precision and at all speeds for rare events and precious samples The Attune Acoustic Focusing Cytometer Precise high collection

More information

Uses of Flow Cytometry

Uses of Flow Cytometry Uses of Flow Cytometry 1. Multicolour analysis... 2 2. Cell Cycle and Proliferation... 3 a. Analysis of Cellular DNA Content... 4 b. Cell Proliferation Assays... 5 3. Immunology... 6 4. Apoptosis... 7

More information

BD FACSCalibur. The flow cytometer for your routine cell analysis needs

BD FACSCalibur. The flow cytometer for your routine cell analysis needs BD FACSCalibur The flow cytometer for your routine cell analysis needs A system with a rich application basis and a modular approach that continues to meet evolving needs of cell analysis worldwide. The

More information

FCAP Array v3.0 Software: A New Tool to Analyze BD Cytometric Bead Array (CBA) Data. Monisha Sundarrajan, PhD BD Biosciences

FCAP Array v3.0 Software: A New Tool to Analyze BD Cytometric Bead Array (CBA) Data. Monisha Sundarrajan, PhD BD Biosciences FCAP Array v3.0 Software: A New Tool to Analyze BD Cytometric Bead Array (CBA) Data Monisha Sundarrajan, PhD BD Biosciences 23 13795 00 Agenda Introduction Overview of BD CBA bead based immunoassays FCAP

More information

Automation of Cell Staining Technical Information Bulletin

Automation of Cell Staining Technical Information Bulletin Automation of Cell Staining Technical Information Bulletin Automation of Cell Staining Using the Biomek 4000 Laboratory Automation Workstation Amy N. Yoder, Sr. Development Scientist and Li Liu, Sr. Development

More information

Setting up and calibration of a flow cytometer for multicolor immunophenotyping

Setting up and calibration of a flow cytometer for multicolor immunophenotyping Journal of Biological Regulators and Homeostatic Agents Setting up and calibration of a flow cytometer for multicolor immunophenotyping J. KRAAN 1, J.W. GRATAMA 1, M. KEENEY 2, J.L. D HAUTCOURT 3 1 Department

More information

INFORMATION ON STEM CELLS/BONE MARROW AND REINFUSION/TRANSPLANTATION SUR703.002

INFORMATION ON STEM CELLS/BONE MARROW AND REINFUSION/TRANSPLANTATION SUR703.002 INFORMATION ON STEM CELLS/BONE MARROW AND REINFUSION/TRANSPLANTATION SUR703.002 COVERAGE: SPECIAL COMMENT ON POLICY REVIEW: Due to the complexity of the Peripheral and Bone Marrow Stem Cell Transplantation

More information

Cell Counting Using the BD Accuri C6 Flow Cytometer

Cell Counting Using the BD Accuri C6 Flow Cytometer Cell Counting Using the BD Accuri C6 Flow Cytometer Koen Verbrugghe, PhD Marketing Applications Specialist BD Biosciences 23-14763- The BD Accuri C6 Flow Cytometer System An affordable, full-featured,

More information

Enhance Sensitivity of FISH Analysis with Highly Purified Multiple Myeloma Cells Using RoboSep, the Fully Automated Cell Separator

Enhance Sensitivity of FISH Analysis with Highly Purified Multiple Myeloma Cells Using RoboSep, the Fully Automated Cell Separator Enhance Sensitivity of FISH Analysis with Highly Purified Multiple Myeloma Cells Using RoboSep, the Fully Automated Cell Separator Benoit Guilbault, PhD Field Applications Scientist t STEMCELL Technologies,

More information

Introduction to Flow Cytometry

Introduction to Flow Cytometry Introduction to Flow Cytometry presented by: Flow Cytometry y Core Facility Biomedical Instrumentation Center Uniformed Services University Topics Covered in this Lecture What is flow cytometry? Flow cytometer

More information

Preparation of cord blood for infusion: bedside thaw, dilute and wash, or somewhere in between

Preparation of cord blood for infusion: bedside thaw, dilute and wash, or somewhere in between Preparation of cord blood for infusion: bedside thaw, dilute and wash, or somewhere in between Donna Wall, MD Director, Manitoba Blood and Marrow Transplant Program ISCT 2012 Disclosures: none The problem:

More information

Processing & Utilization of Cord Blood for Transplant

Processing & Utilization of Cord Blood for Transplant Processing & Utilization of Cord Blood for Transplant 2010-Jan Jan-15 Nicole L. Prokopishyn, PhD HPC Processing Laboratory Director Calgary Laboratory Services Overview Cord Blood Processing Pre-Freeze

More information

Jennifer G. Collins, RN Children s Hospital of Chicago

Jennifer G. Collins, RN Children s Hospital of Chicago Jennifer G. Collins, RN Children s Hospital of Chicago Review the importance of consultation with the stem cell transplant team Review criteria to begin harvest Review ways to modify a harvest procedure

More information

In a number of genetic, hematologic, and oncologic

In a number of genetic, hematologic, and oncologic AMERICAN ACADEMY OF PEDIATRICS Cord Blood Banking for Potential Future Transplantation: Subject Review ABSTRACT. In recent years, umbilical cord blood, which contains a large number of hematopoietic stem

More information

Running head: Body mass index affects stem cell yield

Running head: Body mass index affects stem cell yield Donor body mass index is an important factor that affects peripheral blood stem cell yield in healthy donors after mobilization with granulocyte-colony stimulating factor Running head: Body mass index

More information

The Bone Marrow in Type 1 Diabetes

The Bone Marrow in Type 1 Diabetes The Bone Marrow in Type 1 Diabetes Feasibility of Flow Cytometric Analysis of npod Bone Marrow specimens Paolo Madeddu, MD FAHA University of Bristol UK Miami January, 17 2012 2 BACKGROUND Cardiovascular

More information

Peripheral Blood Stem Cell (PBSC) Collections: Why, What, When. Objectives. Sources of Stem Cells

Peripheral Blood Stem Cell (PBSC) Collections: Why, What, When. Objectives. Sources of Stem Cells Peripheral Blood Stem Cell (PBSC) Collections: Why, What, When Objectives Why do need stem cell transplants What type of cells are we using for stem cell transplants When and how we collect peripheral

More information

Comparative quantification of umbilical cord blood CD34+ and CD34+ bright cells using the ProCount -BD and ISHAGE protocols

Comparative quantification of umbilical cord blood CD34+ and CD34+ bright cells using the ProCount -BD and ISHAGE protocols Brazilian Journal of Medical and Biological Research (2006) 39: 901-906 Quantification of umbilical cord CD34+ cells ISSN 0100-879X 901 Comparative quantification of umbilical cord blood CD34+ and CD34+

More information

International Beryllium Conference, Montreal, Canada March 10, 2005

International Beryllium Conference, Montreal, Canada March 10, 2005 Alternative Lymphocyte Proliferation Tests: BrdU and Flow Cytometry Based Tests International Beryllium Conference, Montreal, Canada March 10, 2005 Tim K. Takaro Department of Environmental and Occupational

More information

Laboratory Procedure Manual

Laboratory Procedure Manual Laboratory Procedure Manual Analyte: Matrix: Method: CD4+ T-Lymphocytes and CD8 T Cells Whole Blood TriCount Method Method No.: Revised: as performed by: Lee Lam or Marjorie Hubbard HIV Immunology and

More information

CFSE Cell Division Assay Kit

CFSE Cell Division Assay Kit CFSE Cell Division Assay Kit Item No. 10009853 Customer Service 800.364.9897 * Technical Support 888.526.5351 www.caymanchem.com TABLE OF CONTENTS GENERAL INFORMATION 3 Materials Supplied 4 Precautions

More information

STEM CELL LEUCOCYTE BIOLOGY. Setting up of an Umbilical cord blood stem cell bank at Institute of Immunohaematology

STEM CELL LEUCOCYTE BIOLOGY. Setting up of an Umbilical cord blood stem cell bank at Institute of Immunohaematology STEM CELL LEUCOCYTE BIOLOGY Setting up of an Umbilical cord blood stem cell bank at Institute of Immunohaematology Objectives: 1. To establish umbilical cord blood stem cell bank, which can be used as

More information

Basic Science in Medicine

Basic Science in Medicine Medical Journal of th e Islamic Republic of Iran Volume 18 Number 3 Fall 1383 November 2004 Basic Science in Medicine ] EXPANSION OF HUMAN CORD BLOOD PRIMITIVE PROGENITORS IN SERUM-FREE MEDIA USING HUMAN

More information

Cord Blood: that other stem cell source. Donna Wall, MD Director, Manitoba Blood and Marrow Transplant Program

Cord Blood: that other stem cell source. Donna Wall, MD Director, Manitoba Blood and Marrow Transplant Program Cord Blood: that other stem cell source Donna Wall, MD Director, Manitoba Blood and Marrow Transplant Program CBMTG April 2012 The problem: In order to perform a BMT from one person to another one needs

More information

XE-2100 Automated Hematology System. Fast, Accurate, Dependable

XE-2100 Automated Hematology System. Fast, Accurate, Dependable XE-2100 Automated Hematology System Fast, Accurate, Dependable Advanced Technology Solutions to Meet your Lab s Needs Even with these challenges, the need for hematology testing has remained steady or

More information

Corporate Medical Policy

Corporate Medical Policy Corporate Medical Policy Hematopoietic Stem-Cell Transplantation for CLL and SLL File Name: Origination: Last CAP Review: Next CAP Review: Last Review: hematopoietic_stem-cell_transplantation_for_cll_and_sll

More information

Public Cord Blood Banking at the National Cord Blood Program (NCBP)

Public Cord Blood Banking at the National Cord Blood Program (NCBP) Public Cord Blood Banking at the National Cord Blood Program (NCBP) A. Scaradavou, MD Medical Director, National Cord Blood Program, New York Blood Center Associate Attending, Pediatric BMT Memorial Sloan-Kettering

More information

Review Article A Review of Factors Influencing the Banking of Collected Umbilical Cord Blood Units

Review Article A Review of Factors Influencing the Banking of Collected Umbilical Cord Blood Units Stem Cells International Volume 2013, Article ID 463031, 7 pages http://dx.doi.org/10.1155/2013/463031 Review Article A Review of Factors Influencing the Banking of Collected Umbilical Cord Blood Units

More information

BLOOD COMPONENTS. Liquid storage, shipment, and cryopreservation of cord blood. Allison Hubel, Dale Carlquist, Mary Clay, and Jeff McCullough

BLOOD COMPONENTS. Liquid storage, shipment, and cryopreservation of cord blood. Allison Hubel, Dale Carlquist, Mary Clay, and Jeff McCullough Blackwell Science, LtdOxford, UKTRFTransfusion0041-11322004 American Association of Blood BanksApril 2004444Original ArticleLIQUID AND FROZEN STORAGE OF CORD BLOODHUBEL ET AL. BLOOD COMPONENTS Liquid storage,

More information

Using BD FACSDiva CST To. Evaluate Cytometer Performance, Create Custom Assay Settings. and

Using BD FACSDiva CST To. Evaluate Cytometer Performance, Create Custom Assay Settings. and Using BD FACSDiva CST To Evaluate Cytometer Performance, Create Custom Assay Settings and Implement Cross-Instrument and Cross-Site Standardization of Assays PART 2 Alan M. Stall Director, Advanced Cytometry

More information

ArC Amine Reactive Compensation Bead Kit

ArC Amine Reactive Compensation Bead Kit ArC Amine Reactive Compensation Bead Kit Catalog no. A1346 Table 1. Contents and storage information. Material Amount Composition Storage Stability ArC reactive beads (Component A) ArC negative beads (Component

More information

CORD BLOOD BANKING FAQ

CORD BLOOD BANKING FAQ CORD BLOOD BANKING FAQ Cord Blood & Stem Cells Q: What is umbilical cord blood (UCB)? A: Bone marrow, peripheral blood and UCB constitute the three primary sources of stem cells. Cord blood, which, until

More information

HAEMATOLOGY LABORATORY

HAEMATOLOGY LABORATORY HAEMATOLOGY LABORATORY Head of Unit : Dr Raudhawati Osman Phone : +603-26155281 Email : raudhaosman@yahoo.com 1. INTRODUCTION The Haematology Unit, Department of Pathology, HKL provides tertiary diagnostic

More information

Introduction to flow cytometry

Introduction to flow cytometry Introduction to flow cytometry Flow cytometry is a popular laser-based technology. Discover more with our introduction to flow cytometry. Flow cytometry is now a widely used method for analyzing the expression

More information

ab139418 Propidium Iodide Flow Cytometry Kit for Cell Cycle Analysis

ab139418 Propidium Iodide Flow Cytometry Kit for Cell Cycle Analysis ab139418 Propidium Iodide Flow Cytometry Kit for Cell Cycle Analysis Instructions for Use To determine cell cycle status in tissue culture cell lines by measuring DNA content using a flow cytometer. This

More information

Too Many B Cells: Chronic Lymphocytic Leukemia and the Role of Flow Cytometry

Too Many B Cells: Chronic Lymphocytic Leukemia and the Role of Flow Cytometry Too Many B Cells: Chronic Lymphocytic Leukemia and the Role of Flow Cytometry by Debby R. Walser-Kuntz Biology Department Carleton College, Northfield, MN Taylor goes in to see her doctor, Dr. Chavez,

More information

hematopoietic stem cells from cord blood: - costless but too expensive? Dr. Vincent Kindler Geneva Cord Blood Bank HUG vincent.kindler@hcuge.

hematopoietic stem cells from cord blood: - costless but too expensive? Dr. Vincent Kindler Geneva Cord Blood Bank HUG vincent.kindler@hcuge. hematopoietic stem cells from cord blood: - costless but too expensive? Dr. Vincent Kindler Geneva Cord Blood Bank HUG vincent.kindler@hcuge.ch Spring water: Manufactured by nature COSTLESS Cord Blood:

More information

Cord Blood Market Trends, circa 2014

Cord Blood Market Trends, circa 2014 GENReports: Market & Tech Analysis Cord Blood Market Trends, circa 2014 > Enal Razvi, Ph.D. Managing Director Select Biosciences, Inc. enal@selectbio.us Topic Introduction and Scope The focus of this GEN

More information

Cord Blood Stem Cell Transplantation

Cord Blood Stem Cell Transplantation LEUKEMIA LYMPHOMA MYELOMA FACTS Cord Blood Stem Cell Transplantation No. 2 in a series providing the latest information on blood cancers Highlights Umbilical cord blood, like bone marrow and peripheral

More information

Corporate Medical Policy Cord Blood as a Source of Stem Cells

Corporate Medical Policy Cord Blood as a Source of Stem Cells Corporate Medical Policy Cord Blood as a Source of Stem Cells File Name: Origination: Last CAP Review: Next CAP Review: Last Review cord_blood_as_a_source_of_stem_cells 2/2001 3/2015 3/2016 3/2015 Description

More information

Platelet Transmission Electron Microscopy and Flow Cytometry 11/15/2015

Platelet Transmission Electron Microscopy and Flow Cytometry 11/15/2015 Welcome to Mayo Medical Laboratories Hot Topics. These presentations provide short discussion of current topics and may be helpful to you in your practice. Today our topic looks at hereditary platelet

More information

ENUMERATION OF LYMPHOCYTE SUBSETS USING FLOW CYTOMETRY: EFFECT OF STORAGE BEFORE AND AFTER STAINING IN A DEVELOPING COUNTRY SETTING

ENUMERATION OF LYMPHOCYTE SUBSETS USING FLOW CYTOMETRY: EFFECT OF STORAGE BEFORE AND AFTER STAINING IN A DEVELOPING COUNTRY SETTING ENUMERATION OF LYMPHOCYTE SUBSETS USING FLOW CYTOMETRY: EFFECT OF STORAGE BEFORE AND AFTER STAINING IN A DEVELOPING COUNTRY SETTING Sanju Jalla*, Sunil Sazawal***, Saikat Deb***, Robert E. Black**, Satya

More information