FIRE DETECTION SYSTEMS ALARM STRATEGIES 2.0. New Version

Size: px
Start display at page:

Download "FIRE DETECTION SYSTEMS ALARM STRATEGIES 2.0. New Version"

Transcription

1 FIRE DETECTION SYSTEMS STRATEGIES 2.0 New Version

2 STRATEGIES TO FIT IN EVERY SITE A former factory now as a call center: Each alarm concept hat to meet the actual conditions of the building. A general non specific solution does not exist. Alarms in commercial buildings must be especially efficient and economical useful. Planners, installers and operators expect alarming strategies, with which they can react individually to structural requirements. The base for a relaible alarm is a long-lasting, uninterrupted and distinct signal for a sufficient time. To support this base, many national rules and norms require an alarm signal interruption freedom for a period of 30 min. The alarm concepts of the system detect 3000 from JOB Detectomat are based on these principles and integrate well pioneering technology providing a secure and convenient alerts. In case of alarm it is important to have a good alarm organization for persons in the building and to forward the alarm to the fire brigade. To ensure this as soon as possible, comprehensive approaches are needed. There are several opportunities for an efficient alarming strategy. The choice of the presented concepts is dependend of the specific requirements of the project and the demands of architects, designers and fire services. On the following pages we would like to present our different concepts from Basic Alarm up to Premium Alarm. 2 3

3 BASIC SMART The proven stub technology offers signifi cant advantages: For further optimization of the cabelling, it is possible, to use a second pair of wires in the same cable for the alarm lines. The signalling device cables are monitored by the fire control panel The connection of different signalling devices in high quantities is possible without any problems The realization of the cabelling is simple and cost-efficient Note: Depending on existing requirements it maybe necessary to use fi re resistant cables and to enhance the fi re control panel (by E30 housing) Figure 1 Figure 2 PL3200 T PL3200 T + PL 3300 O + PL 3300 O Key The cables in the drawing are used in the following way: Red lines are lines with active participants e.g. optical and acoustic alarming devices, which need quite a lot of energy. Here you can connect conventional devices which are not addressed. The cables are terminated at the end with a resistor to notice that when a line is open or a short circuit is existing. In case of error you will only know, that the alarm line is disturbed without knowing the exact location.. Except fi gure 4 - here the energy fl ows through the control line (Loop) - therefore, the number of alarming devices that can be supplied with energy is limited. Green lines are representing Loop cables where are connected addressable devices like detectors and modules are connected. E30 housing Optical alarm Acoustic alarm Voice alarm Addressable detector Similar to figure 1, but two lines in one cable. 4 5

4 COMFORT 1 COMFORT 2 In buildings with many of fi re compartments, an optimal alarm can be achieved in the individual sections by the distribution of externally supplied energy. This can be achieved via control modules which include a power supply. Advantages of this alarming solution: The Loop-controlled alarm via the signalling device family is fully performed over the Loop line. In this case the Loop cable is used for the detection and alarm. The technical features and the unique emission characteristics of: No requirement of fi re restistant cables towards the industrial fi re compartments No requirement of an E30 housing The connection of different signalling devices in high quality is possible without any problems Effective coordination of power supplies Note: In this solution you can realize the signalling line inside the same cable as described in the SMART variance, too One single line for detection and alarm functions for easy handling during installation Regardless of the software version of the DC3500, see Premium 1 and 2 Alarm There are only acoustic alarms connectable Mixed operation with the other alarm concepts is possible Note: In the alarm strategy you can calculate the energy ressources via the JOB Detectomat System Configurator. Figure 3 Figure 4 PL3200 T TI TI Alarm box Alarm box IOM3311 Alarm box The alarm boxes are power supplies with integrated modules as Loop-connection. 6 7

5 PREMIUM 1 PREMIUM 2 With the version 3.2 of the fi re detection panel generation of dc3500 JOB Detectomat provides additional features for the Loop-controlled alarm functions inside the system: Additional to the Sounder there s the opportunity to use optical/acoustical combi signalling devices (up to 30 sounder, up to 10 combination - depending on the Loop structure The signal transmitter can be programmed in time dependencies and associated alarm scenarios The further development of the alarming concept that will be used with version 3.3 of the dc3500 is an improved Loop-controlled signalling device. This concept will make it possible to connect up to 126 different devices of the family on the Loop and to supply them with energy. In addition to the acoustic and optical / acoustic devices then this series will be additionally available to realize voice alarming. Via the dc3500 the Conus devices can be controlled timely staggered and different sound and speech signals can be selected. This gives you the option for an individual adaptation to the respective alarm application. More alarm solutions, such as the transmission to paging systems, the interaction with voice alarm systems (VAS) and the connection to telephone systems are ensured via the interfaces of the fire control panel dc3500. Figure 5 Figure 6 In this alarm strategy the signalling devices optical and acoustic (cover with clear LEDs) can be connected directly to an addressable detector. The energy for the is taken from the Loop. The difference to figure 4-5 is that the devices can be driven timely staggered (first qty 1- then time X - then qty 2, etc.) Both lines (energy and detection) are parallel in one cable as Loop. With this solution you can transport energy for all devices in one loop (up to 126). 8 9

6 INTELLIGENT SIGNALLING DEVICE The Loop-powered sounder PL 3300 S 1 SE from the family is part of the JOB Detectomat portfolio. This sounder with isolator replaced now finally his predecessor, the Loop sounder LS 3300, which previously was parallely delivered. This new generation of signalling devices is especially comfortable to use in every site. Because of the integrated detector base the detectors of the PL series can be installed quickly and easily on top of the alarm devices, on walls as well as ceilings. With the same cable length can be driven up to 60% more alarm devices can be connected in a Loop caused due the new circuit technologies. If the number of alarm devices equal, a doubling of the Loop cable length is guaranteed. This reduces cable costs and wireing the building. A direct sound outlet provides decisive benefits. Regardless of whether the sounder is combined with a detector or acts as an autonomous alarm device, the volume and emission characteristics of the devices are always unchanged and louder than conventional devices. This optimal sound radiation makes it possible to equip larger object surfaces with the same results with less sounders. Acoustic signalling device THE ADVANTAGES AT A GLANCE: Optical / acoustic signalling device 60% more alarm devices on a Loop with the same cable length Doubling the Loop cable length for the same alarm device quantity Easy installation with an integrated detector base (on walls and ceilings) Optimum sound radiation, so that with a smaller number of signal heads, the same results are obtained Features The same volume regardless of the Loop voltage Optimized homogeneous radiation Monitoring and supply directly from the Loop protocol Built-in automatic reset function with signal external signaling devices on / off the control panel monitoring the operating state via the Loop3000 Independent programming (automatic and manual) using autonomous Loop address Built-insulator 28 different tones programmable via DIP switches Volume adjustable via integrated DIP switches Integrated detector base for the detectors series PL Cover included CT PL PL Voice acoustic s s s optical / acoustic s s addressable s s s optical / acoustic / voice alarm s 10 11

7 KEYS AND S ( PL VOICE) No Sound Key Description Course 1 School Bell Complex 2 FP Telecoms BS Alternating tone Alternating 800 / Hz 3 BS 5839 Pt1 Alternating tone Alternating 800 / Hz 4 BS 5839 Pt1 Pulse tone Intermittent ms on / 500 ms off 5 BS 5839 Pt1 Pulse tone Intermittent ms on / 500 ms off 6 BS 5839 Pt1 Pulse tone Intermittent ms on / 1000 ms off acoustic optical and acoustic optical and acoustic 7 BS 5839 Pt1 Continuous tone Continous 970 Hz 8 BS 5839 Pt1 Swelling Sweep Tone 800 Hz to Hz 9 BS 5839 Pt1 Swelling Sweep Tone 800 Hz to Hz COMPARISON CHART A direct sound radiation outlet that characterizes the appearance of the device, offers the user significant advantages: Regardless of the use of the sounder, e.g. in combination with a detector or as an autonomous alarm transmitter is the volume and radiation characteristics of the devices always continous. The newly developed design offers optimal sound radiation, so that larger object surfaces can be equipped with the same results with less sounders. So that the design of a site with this equipment is considerably simplified - thanks to. normal sounder low-cost sounder 10 DIN Tone DIN Pt3 Decongestant Sweep Tone 1200 Hz to Hz 11 French Fire Sound Pulse tone 554 Hz for 100 ms / 440 Hz for 400 ms 12 NL - Slow Whoop Swelling Sweep Hz, 3500 ms / 500 ms off 13 US-Horn Continuous tone Contionus 485 Hz 14 US-Horn with Temporal Pulse tone Intermittent 485 Hz (@ 500 ms on / 500 ms off) 3 times / 1500 ms off / Repeat VOICE SAMPLES No Text Warning, warning. This is a hazard alarm Warning, warning. This is a fire alarm 3 Please wait for further instructions 4 Please evacuate this floor immediately 5 Please leave the building using the nearest exits The following languages are available for the load requirement: German, English, French, Italian, Spanish, Dutch, Portuguese 6 The release of extinguishing gas is imminent The hazardous situation has been resolved 8 This is a test announcement 9 Please remain calm and wait for further instructions 12 13

8 OPERATION OF FIRE S detect3004 plus IN ACCORDANCE WITH MLAR ADDITIONAL RESTRICTIONS / ADVICE FOR OPERATION IN ACCORDANCE WITH MLAR The Specimen Wiring Systems Directive (MLAR) from 2005 defines, among other things, building regulations for the isolation of wiring systems and is applicable building legislation in almost all federal states. The MLAR also applies for maintaining the functionality of electrical wiring in the event of a fire, and thus also for MLAR compliant fire alarm systems. max. 300m max. 20 detectors max. 300m max. 20 detectors max. 300m max. 20 detectors M1 M20 PL M1 M20 PL M1 M20 Resulting from this is one of the main requirements for the operation of a fire alarm system in accordance with MLAR: An interruption of the alarm in case of an error (for example, through a short circuit in the Loop) must only last for a maximum 5 seconds. With the fire alarm control panel detect 3004 plus you can achieve a MLAR-compliant fire alarm system in two ways: 1st option (conventional way): Using the sounder output module OMS 3301 Requirement: Sounder output module OMS 3301 Conventional sounder with external power supply 2nd option: MLAR IN PRACTICE The realisation of a fire alarm system in accordance with MLAR is not trivial and requires careful planning. A maximum of 25 PL 3300 SX SE MLAR Loop sounders can be installed per Loop. In practice, the real number of all devices of a Loop depends on the local circumstances (note here Loop calculator). The use of the Loop calculator is therefore imperative for a smooth functioning of the fire alarm system in accordance with MLAR. However, there are limitations as soon as the Loop runs in a combined operation. The maximum number of Loop sounders decreases as soon as certain Loop devices are used. The Loop devices permissible in MLAR operation are divided into three categories: Start Loop i It is imperative that the maximum total cable length of the Loop, as well as the maximum total number of Loop devices are calculated in the Loop calculator/configurator. The maximum cable length between two PL Loop sounders with an active MLAR function or between the start/end of the Loop and a PL Loop sounder with an active MLAR function is 300 meters. There may be a maximum of 20 Loop devices between two PL Loop sounders with an active MLAR function or between the start/ end of the Loop and a PL Loop sounder with an active MLAR function. End Loop Like its predecessors, the Loop module DLI3240 PSM can recognise creeping short circuits. The function for the exact position identification has been integrated into I-Check from version 4.25 onwards and must be started manually. If you want to convert an existing Loop to operate in accordance with MLAR, with I-Check from version 4.25 onwards you can determine whether there is a device without a separator in the Loop. I-Check emits an error message in this case. The Loop device must then be removed and, if necessary, exchanged for an MLAR-compliant device. Use of the Loop sounder PL 3300 Sx SE Requirement: Loop sounder PL 3300 Sx SE with activated MLAR function. In the factory settings for the PL 3300 Sx SE the MLAR feature is disabled. This function can be activated with Easy-Check from version 2.60 onwards and/or I-Check from version 4.25 onwards. Loop module DLI3240PSM with software V9 Only Loop devices with separator permitted Loop elements CATEGORY 1 PL 3300 O/T/ OT/OTi/OTi Fusion Loop elements CATEGORY 2 PL 3300 PBD PL 3300 SBD PL 3300 MCP IOM 3311 Loop elements CATEGORY 3 AMD 3311 OMS 3301 MINI OMS 3301 PL 3300 COBT TCM 3300 JOB DETECTOMAT SYSTEM CONFIGURATOR! Devices without separators, such as the series PL 32XX, are generally not permitted. If these are used, the commissioning of the fire alarm system in MLAR mode is not possible. The diagram shows which categories may be used depending on the number of PL 3300 Sx SE Loop sounders: CATEGORY 1 CATEGORY 2 CATEGORY Number of used Loop Sounder no further elements allowed Example: When using eleven Loop sounders, you may only install Loop devices from category 2 and category 3. The system configurator is an easy to understand and simple software tool for the planning of fire alarm systems. Even with little or no knowledge of the JOB Detectomat product portfolio, projects can be configured safely and reliably. Both the automatic and the manual configuration of a project include a plausibility check. Required system components (e.g. modules, power supplies) are automatically added. The recorded prices allow transparent budget calculation, including output of full specifications in various output formats (GAEB, Excel, for example). In addition to the integrated product catalogue, a detailed description with a picture is available for each item. Through the auto-update feature, it is guaranteed, at all times, that the software and the products stored are up to date. With the help of the integrated loop calculator, the arrangement of the individual detectors in the property can be planned in detail. The function is thereby ensured and any critical points (e.g. brownout) are indicated. You can find the configurator in the partner area on our homepage under Planning and tender

9 Detectomat GmbH An der Strusbek Ahrensburg Germany job-group.de

Product Information Fire alarm panel 8000 C

Product Information Fire alarm panel 8000 C Product Information Fire alarm panel 8000 C Fire alarm panel 8000 C, basic configuration In common with all modern Esser panels, the 8000 C fire alarm panel is based on high-performance ringbus technology.

More information

25 Years of Manufacturing Excellence INFINITY. The Intelligent 2 Wire Fire Detection System for Professionals

25 Years of Manufacturing Excellence INFINITY. The Intelligent 2 Wire Fire Detection System for Professionals INFINITY The Intelligent 2 Wire Fire Detection System for Professionals Infinity ID 2 The intelligent 2 wire fire detection system for professionals In a nutshell Zeta Alarm Systems is proud to introduce

More information

Professional fire alarm panel for small and medium-sized objects. Compact

Professional fire alarm panel for small and medium-sized objects. Compact Compact Professional fire alarm panel for small and medium-sized objects ESSER by Honeywell: The experts for safety in buildings With a comprehensive and future-oriented portfolio in the fields of fire

More information

AlarmSense 2-wire detection and alarm system. Product Guide

AlarmSense 2-wire detection and alarm system. Product Guide AlarmSense 2-wire detection and alarm system Product Guide Contents What is AlarmSense? 2 The purpose of AlarmSense 4 How AlarmSense works 4 Alarmsense Features 5 Detector removal monitoring 5 Priority/non-priority

More information

Voice alarm system E100 the new standard for safe evacuation

Voice alarm system E100 the new standard for safe evacuation Voice alarm system E100 the new standard for safe evacuation Clear announcements and future-proof protection in case of fire Answers for infrastructure. E100 from Siemens so everyone knows what to do when

More information

25 Years of Manufacturing Excellence. Premier Quatro Addressable Fire Alarm System. Assessed to ISO 9001: 2008

25 Years of Manufacturing Excellence. Premier Quatro Addressable Fire Alarm System. Assessed to ISO 9001: 2008 Premier Quatro Addressable Fire Alarm System Premier Quatro 4 Loop Analogue Addressable Fire Alarm Panel The Premier Quatro is the new 4 loop analogue Alarm Systems. It is available in 1, 2, 3 or 4 loop

More information

TS510 & TS500. Installation & User Guide. Compatible Equipment

TS510 & TS500. Installation & User Guide. Compatible Equipment Installation & User Guide Compatible Equipment TS510 REM - Remote Keypad 9040 - Loudspeaker DC54/58 - Digital Communicator SD1+ - Speech Dialler 496525 Issue A 1 of 10 TS510 and TS500 Overview Introduction

More information

Page 162. Page 154. Page 158 Page 146. Page 157. Page 152. Page 160. Page 149. Page 159. Page 156. Page 150

Page 162. Page 154. Page 158 Page 146. Page 157. Page 152. Page 160. Page 149. Page 159. Page 156. Page 150 Page 162 NEW Page 154 Page 158 Page 146 Page 157 Page 152 Page 160 Page 159 Page 149 Page 156 Page 150 Summary Audible Signal Devices Page 151 Page 163 Page 148 installation version Free-standing Electronic

More information

Fire Alarm system Installation Guide

Fire Alarm system Installation Guide Fire Alarm system Installation Guide Fire Alarm System Categories Systems designed for Protection of Property only, fall into two classifications P1 or P2. but a manual system is also needed, then this

More information

MSL1000 Monitored Serial Link Interface Manual V1.01

MSL1000 Monitored Serial Link Interface Manual V1.01 Audix Systems, Station Road, Wenden, Saffron Walden, Essex, CB11 4LG. Telephone: +44(0)1799 540888 Facsimile: +44(0)1799 541618 www.tycosafetyproducts-europe.com www.audixsystems.co.uk MSL1000 Monitored

More information

Analogue addressable devices

Analogue addressable devices Discovery Analogue addressable devices from Channel Safety Systems Discovery Analogue addressable devices Discovery is a range of high-specification, intelligent fire detectors that are developed to meet

More information

PLAN REVIEW GUIDE FOR FIRE ALARM

PLAN REVIEW GUIDE FOR FIRE ALARM PLAN REVIEW GUIDE FOR FIRE ALARM PROJECT NAME: PERMIT # PROJECT ADDRESS: CONTACT PERSON: PHONE Fire alarm system installation information shall be provided on the appropriate architectural and electrical

More information

XR1. Intruder alarm system Operating Instructions. Unset system indications. Set System indication

XR1. Intruder alarm system Operating Instructions. Unset system indications. Set System indication h m mi R s t P o S t A XR EP 9 XR G panel with built-in keypad 2 5 6 7 Power A tack 0 2 5 6 7 9 Intruder alarm system Operating Instructions These operating instructions cover the following intruder system:

More information

NELSON VOLTAGE MONITOR INSTALLATION & PROGRAMMING MANUAL

NELSON VOLTAGE MONITOR INSTALLATION & PROGRAMMING MANUAL NELSON VOLTAGE MONITOR INSTALLATION & PROGRAMMING MANUAL CONTENTS GENERAL INFORMATION...3 INSTALLATION...3 FIELD WIRING...4 PROGRAMMING...4 Circuit Monitor Options...5 Power Frequency...5 Alarm Silence

More information

LIFT CONTROL SYSTEMS CATALOGUE 2007

LIFT CONTROL SYSTEMS CATALOGUE 2007 LIFT CONTROL SYSTEMS CATALOGUE 2007 All Your Needs For Elevators INDEX 1. Lift Control Cards... 3 2. Speed Control Units... 7 3. Emergency Rescue Cards... 8 4. Lift Control Panels... 10 5. Photocells...

More information

EDA-Z5008 & Z5020. Radio Fire Alarm System. User Manual

EDA-Z5008 & Z5020. Radio Fire Alarm System. User Manual EDA-Z5008 & Z5020 Radio Fire Alarm System User Manual Electro-Detectors Ltd. Electro House, Edinburgh Way Harlow, Essex, CM20 2EG UK Tel: 01279 635668. Fax 01279 450185 Email: eda@electrodetectors.co.uk

More information

TELIKOU Intercom System. MS-500(4+1 channel) Main Station Instruction Manual

TELIKOU Intercom System. MS-500(4+1 channel) Main Station Instruction Manual TELIKOU Intercom System MS-500(4+1 channel) Main Station Instruction Manual TELIKOU Systems All Rights Reserved While TELIKOU makes every attempt to maintain the accuracy of the information contained in

More information

CSP Combined Series. Telephone Door Entry. with. Proximity Keyfob Access

CSP Combined Series. Telephone Door Entry. with. Proximity Keyfob Access CSP Combined Series Telephone Door Entry with Proximity Keyfob Access PD-094 Issue 3 General Description The CSP series systems are combined Door Entry Telephone and Proximity Access Systems. The entrance

More information

WD-AMX Water Detection Controllers

WD-AMX Water Detection Controllers Page 1 of 5 WD-AMX Water Detection Controllers Features: Benefit: LED Status of leak status VFC output Audible alarm Auto or manual reset alarm output Uses an isolated AC signal which prevents oxidation

More information

Maximum uptime and optimum fire safety for your data center

Maximum uptime and optimum fire safety for your data center Maximum uptime and optimum fire safety for your data center Integrated and tailored fire safety solutions from one partner Answers for infrastructure. Complete solutions for a safe data center with a single

More information

Carbon Monoxide (CO) Detection PRODUCTS. Accessories Conventional Detectors

Carbon Monoxide (CO) Detection PRODUCTS. Accessories Conventional Detectors Carbon Monoxide (CO) Detection PRODUCTS Accessories Conventional Detectors 2 Complete CO Detection The system-connected CO1224T and CO1224TR CO detectors with RealTest provide early warning by using reliable

More information

868 MHz. VdS. Original size Aluminium. The first ARGUS Smoke Detector System with VdS* approval. * Association of. Polar white.

868 MHz. VdS. Original size Aluminium. The first ARGUS Smoke Detector System with VdS* approval. * Association of. Polar white. Original size Aluminium 868 MHz VdS GEPRÜFT The first ARGUS Smoke Detector System with VdS* approval. * Association of 22 property insurers Polar white Dark brazil ARGUS SMOKE DETECTORS. Increased safety

More information

BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEM EURO ALARM WIRELESS BURGLAR ALARM SYSTEM OASIS

BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEM EURO ALARM WIRELESS BURGLAR ALARM SYSTEM OASIS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEM EURO ALARM WIRELESS BURGLAR ALARM SYSTEM OASIS BURGLAR ALARM SYSTEM EURO ALARM Six zones with the following connection capabilities: One

More information

SECURIT 800L+ CONTROL PANEL

SECURIT 800L+ CONTROL PANEL USER MANUAL SECURIT 800L+ CONTROL PANEL COMPANY PROFILE IntelliSense have been successfully making security products for over 20 years and lead the security industry throughout the world with many innovative

More information

conventional system operation

conventional system operation conventional system operation detection line operation Conventional detection systems normally operate on a 24VDC line. In the standby condition, the detectors will draw a low current, typically less than

More information

GST301. (Single Protection Zone) Operation Manual

GST301. (Single Protection Zone) Operation Manual GST301 Gas Extinguishing Control Panel (Single Protection Zone) Operation Manual 2 of 19 CONTENTS 1 OVERVIEW... 4 2 TECHNICAL DATA... 4 3 STRUCTURES... 5 3.1 FRONT SURFACE DESCRIPTION... 5 3.1.1 Indicators...

More information

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10 TECHNICAL SPECIFICATIONS Page 1 of 10 FIRE DETECTION AND ALARM SYSTEM Scope Furnish a complete 24V DC conventional, electrically supervised, zone annunciated, fire detection and alarm system as specified

More information

Local SecurityNetwork We know what it s all about

Local SecurityNetwork We know what it s all about Local SecurityNetwork We know what it s all about 2 A New Generation of Security *Local SecurityNetwork PSTN GSM IP LSN the Local SecurityNetwork bus system launched by Bosch unifies fire and intrusion

More information

HM-W536 Install Guide

HM-W536 Install Guide HM-W536 Install Guide 9/13/2013 IMPORTANT SAFETY INSTRUCTIONS Warning - When using electrical devices, basic safety precautions should be followed to reduce the risk of fire, electrical shock or injury.

More information

How To Set A Timer On A Gg System

How To Set A Timer On A Gg System ZONE ZONE 2 ZONE ZONE ZONE 5 ZONE 6 ZONE 7 ZONE Power PA XR2/ XR2+ Intruder alarm system Operating Instructions ZONE ZONE 2 ZONE ZONE ZONE 5 ZONE 6 ZONE 7 ZONE 0 2 5 6 7 9 Omit Prog Remote LED keypad 0

More information

9452/9453 Installation and User Guide

9452/9453 Installation and User Guide 9452/9453 Installation and User Guide Compatible Equipment 9425 Remote Keypad 9040 Internal Sounder 660 Speech Communicator 8440 4-Channel Minicom 496330 Issue 1 1 of 10 9452/3 Introduction The 9452 and

More information

D200+ Auto-Dialler Installation/Operators Manual

D200+ Auto-Dialler Installation/Operators Manual D200+ Auto-Dialler Installation/Operators Manual Bell System (Telephones) Ltd. Presley Way, Crownhill, Milton Keynes, MK8 0ET D200+ Software Version 1.0 Contents General Description...3 Central Station

More information

LIFT CONTROL SYSTEMS CATALOGUE 2007

LIFT CONTROL SYSTEMS CATALOGUE 2007 LIFT CONTROL SYSTEMS CATALOGUE 2007 All Your Needs For Elevators INDEX 1. Lift Control Cards... 3 2. Speed Control Units... 7 3. Emergency Rescue Cards... 8 4. Lift Control Panels... 10 5. Photocells...

More information

Fire detection equipment

Fire detection equipment PRODUCT CATALOG Fire detection equipment www.apollo-fire.com Apollo Fire Detectors is one of the world s largest manufacturers of fire detectors, modules and notification devices. Established in 1980,

More information

Automatic Telephone Dialer TD-101(W)

Automatic Telephone Dialer TD-101(W) Automatic Telephone Dialer TD-101(W) The TD-101 is an automatic dialing device which can transmit prerecorded information via the telephone line. The dialer can send two different 10 second voice messages

More information

MINERVA MX MX Virtual Multi-Sensor Detectors

MINERVA MX MX Virtual Multi-Sensor Detectors DATASHEET MINERVA MX MX Virtual Multi-Sensor Detectors Over 20 fire detection modes Tyco MX FASTLOGIC Expert algorithms MX HPO detection Algorithms Up to 250 detectors per loop Optional bi-directional

More information

(68.52) X. June 2000 Supercedes February 2000. xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we look @ business differently

(68.52) X. June 2000 Supercedes February 2000. xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we look @ business differently (68.52) X June 2000 Supercedes February 2000 xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM.... we look @ business differently XENEX SYSTEM ARCHITECTURE Note: This schematic is for guidance only please

More information

DS 1722-010B LBT 8546 SINGLE-FAMILY HANDS-FREE COLOUR VIDEO KIT WITH VIDEO DOOR PHONE ANSWERING SERVICE. Ref. 1722/71 USER HANDBOOK

DS 1722-010B LBT 8546 SINGLE-FAMILY HANDS-FREE COLOUR VIDEO KIT WITH VIDEO DOOR PHONE ANSWERING SERVICE. Ref. 1722/71 USER HANDBOOK Mod. 1722 DS 1722-010B LBT 8546 SINGLE-FAMILY HANDS-FREE COLOUR VIDEO KIT WITH VIDEO DOOR PHONE ANSWERING SERVICE Ref. 1722/71 USER HANDBOOK The CD supplied contains the handbook full version with traslation

More information

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell Data, installation, operation and maintenance 4 & 8 Zone Fire Panels Zircon range BARDIC by Honeywell LED flashing LED Continuous FAULT DISABLE/TEST Power General Fault Sounder Fault/ Disable System Fault

More information

AUTODIALLER / QUICKDIALLER - SA132

AUTODIALLER / QUICKDIALLER - SA132 AUTODIALLER / QUICKDIALLER - SA132 INSTRUCTION LEAFLET ENGLISH www.thermomax-group.com CONTENTS 1 SETUP AT A GLANCE... 2 2 FOREWORD....... 3 3 INSTALLATION...... 4 4 KEYPAD AND INDICATORS...... 5 SETTING

More information

2 4PI175 issue 1_6/01. How to unset system in alarm. Programs 1, 2 and 3. Access codes. How to operate Personal Attack

2 4PI175 issue 1_6/01. How to unset system in alarm. Programs 1, 2 and 3. Access codes. How to operate Personal Attack Access codes Contents Unset system indications - - - - - - - - - - - System indication - - - - - - - - - - - - Access codes - - - - - - - - - - - - - - - - How to operate Personal - - - - - - How to unset

More information

Maximum uptime and optimum fire safety for your data center

Maximum uptime and optimum fire safety for your data center Maximum uptime and optimum fire safety for your data center Integrated and tailored fire safety solutions from one partner Answers for infrastructure. Complete solutions for a safe data center with a single

More information

Triple Waveband Infra-Red Flame Detection

Triple Waveband Infra-Red Flame Detection Minerva S200PLUS Ex ia Intrinsically Safe & Ex d Flameproof Solar Blind Flame Detectors Triple Waveband Infra-Red Flame Detection Key Features Unrivalled black body rejection over a wide range of source

More information

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems EN Security System CM705B CM705B - Universal Expander Module The CM705B universal expander provides a cost effective way

More information

Process Alarm Solutions

Process Alarm Solutions Process Alarm Solutions Reliable Supervision and Control www.selco.com SELCO flexible alarm panels for supervision and control SELCO provides efficient and reliable solutions for alarm monitoring of electrical

More information

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE DESCRIPTION MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE DESCRIPTION The SST Model 5010 Two Channel Smoke/Fire Detection Module provides two independent detection input channels for the NOVA-5000

More information

Car Alarm Series 2 B 2 Buttons

Car Alarm Series 2 B 2 Buttons Car Alarm Series 2 B 2 Buttons G22 SE (External - Shock Sensor) Version 3 Software 67 Plus www.geniuscaralarm.com 21 CAR ALARM GENIUS Series 2B 2 Buttons - G22 Se (External Shock Sensor) Module controlled

More information

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.

More information

BLOCK OCCUPANCY DETECTOR WITH SEMAPHORE OPERATION BOD1/DAP4-BR

BLOCK OCCUPANCY DETECTOR WITH SEMAPHORE OPERATION BOD1/DAP4-BR BLOCK OCCUPANCY DETECTOR WITH SEMAPHORE OPERATION BOD1/DAP4-BR This Block Occupancy Detector recognises the current drawn by moving trains within a block, and can operate a number of built-in programs

More information

FIREDEX 2200. Conventional Fire Panels

FIREDEX 2200. Conventional Fire Panels 68 Flexible, high specification system Choice of 1, 2, 4 or 8 zones Simple one-shot auto-reset user test facility Approved to EN54 Maintenance free poly switch circuit protection, with auto reset Class

More information

HAM841K ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS

HAM841K ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS USER MANUAL USER MANUAL ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS INTRODUCTION The (HA-841K) is a complete

More information

A.1. a Division of Pittway Corporation. Documento: M-010.1-MGAS-ENG. Edizione: 01/1997 Rev.:

A.1. a Division of Pittway Corporation. Documento: M-010.1-MGAS-ENG. Edizione: 01/1997 Rev.: Documento: M-010.1-MGAS-ENG Edizione: 01/1997 Rev.: A.1 a Division of Pittway Corporation FRONT PANEL & VISUAL INDICATIONS GENERAL TROUBLE GENERAL PROGRAMMING IN PROGRESS ENABLE/ALARM/TROUBLE (ZONE 1 ALARM

More information

Kentec Electronics Ltd. Units 25-27 Fawkes Avenue Questor Dartford Kent DA1 1JQ England Tel: +44(0)1322 222121 Fax: +44(0)1322 291794

Kentec Electronics Ltd. Units 25-27 Fawkes Avenue Questor Dartford Kent DA1 1JQ England Tel: +44(0)1322 222121 Fax: +44(0)1322 291794 Units 25-27 Fawkes Avenue Questor Dartford Kent DA1 1JQ England Tel: +44(0)1322 222121 Fax: +44(0)1322 291794 Kentec Electronics Ltd. E-mail: sales@kentec.co.uk Web: www.kentec.co.uk Loop Explorer V6.00

More information

INTRODUCTION. The data provided is for The Standard Products and any variation will be dealt with at the end of this manual.

INTRODUCTION. The data provided is for The Standard Products and any variation will be dealt with at the end of this manual. INTRODUCTION The information provided herein covers the range of products known as the 'Sensor 901' series. The range of equipment is designed to meet the requirements of BS 5839 parts 1 & 4 1988. The

More information

Current Loop Application Note 1495

Current Loop Application Note 1495 Current Loop Application Note Document No. CLAN1495 International Headquarter B&B Electronics Mfg. Co. Inc. 707 Dayton Road -- P.O. Box 1040 -- Ottawa, IL 61350 USA Phone (815) 433-5100 -- General Fax

More information

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 19

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 19 TECHNICAL SPECIFICATIONS Page 1 of 19 FIRE DETECTION AND ALARM SYSTEM Scope Furnish a complete 24V DC analogue addressable, electrically supervised, zone annunciated, fire detection and alarm system as

More information

Conventional Fire Detection and Extinguishant Control System Specification

Conventional Fire Detection and Extinguishant Control System Specification Conventional Fire Detection and Extinguishant Control System Specification Page 1 of 9 Scope Furnish a complete 24VDC Conventional, electrically supervised, combined fire detection and extinguishant release

More information

CM702 PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

CM702 PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET CM702 PROGRAMMABLE THERMOSTAT FEATURES Attractive slim, modern styling makes it ideal for location in any type of home. 24-hour heating program. Up to 4 daily independent time and temperature level changes

More information

PRODUCT CATALOGUE. www.detectomat.com

PRODUCT CATALOGUE. www.detectomat.com PRODUCT CATALOGUE 20 06 The Group contents 1. fire control panels 1.1 detect 3004 fire control panel and accessories...4-11 1.2 detect 3016 fire control panel and accessories...12-17 1.3 detect 3004/3016

More information

IEC 61850 in ZX Gas-insulated medium voltage switchgear

IEC 61850 in ZX Gas-insulated medium voltage switchgear IEC 61850 in ZX Gas-insulated medium voltage switchgear IEC 61850 in ZX Just as the supply of electrical power is becoming more and more important in a networked world, demands for the integration of electrical

More information

Product Information Sheet UH36 Hi Pot Tester

Product Information Sheet UH36 Hi Pot Tester Product Information Sheet UH36 ETL Prüftechnik GmbH Telefon: +49 711 83 99 39-0 E-Mail: info@etl-prueftechnik.de Carl-Peters-Straße 23 D-70825 Korntal-Münchingen Telefax: +49 711 83 99 39-9 Internet: www.etl-prueftechnik.de

More information

Multi-Protocol decoder 76 400

Multi-Protocol decoder 76 400 Multi-Protocol decoder 76 For locomotives with DC motors on digital layouts operating in the DCC- and Motorola data format. Features Regulated multi-protocol decoder for DCC and Motorola Suitable for DC

More information

TECHNOLOGY RESEARCH AND DEVELOPMENT More Than Alarm Anna Kołodziej-Saramak

TECHNOLOGY RESEARCH AND DEVELOPMENT More Than Alarm Anna Kołodziej-Saramak TECHNOLOGY RESEARCH AND DEVELOPMENT More Than Alarm Anna Kołodziej-Saramak The purpose of the voice alarm systems (VAS) is to inform people about hazards in a possibly efficient way (which, unfortunately,

More information

Power network telecommunication

Power network telecommunication www.siemens.com Power network telecommunication Teleprotection Answers for infrastructure and cities. Binary I/O The best protection against high-voltage grid failures When it comes to managing power networks,

More information

Technical Description. Multifunctional Desk-Top Call Station Digital Version 8, 16 Keys L.No. 1 760 4, 1 761 5

Technical Description. Multifunctional Desk-Top Call Station Digital Version 8, 16 Keys L.No. 1 760 4, 1 761 5 Technical Description Multifunctional Desk-Top Call Station Digital Version 8, 16 Keys L.No. 1 760 4, 1 761 5 Contents 1. General remarks 2. Design 3. Block diagram 4. Function 4.1 Controller system with

More information

Emergency voice communications Product Name

Emergency voice communications Product Name Product Name 76 EATON FIRE AND VOICE ALARM SYSTEMS CFCC2556 January 2015 Contents Contents Emergency voice communications Panels Network exchange units 78 Non network exchange units 80 Devices Outstations

More information

welcome to our world fire alarm systems - series 600 www.staticsystems.co.uk

welcome to our world fire alarm systems - series 600 www.staticsystems.co.uk Static Systems Group PLC Heath Mill Road, Wombourne Staffordshire WV5 8AN. United Kingdom. Tel: +44 (0) 1902 895551 Fax: +44 (0) 1902 324969 www.staticsystems.co.uk welcome to our world In line with our

More information

TX GSM SMS Auto-dial Alarm System. Installation and User Manual

TX GSM SMS Auto-dial Alarm System. Installation and User Manual TX GSM SMS Auto-dial Alarm System Installation and User Manual Product Features: 1. 16 wireless zones, 3 wired zones alarm system, suitable for small to medium size offices and homes. 2. The system uses

More information

nr 28 nr 68 nr 4 nr 1

nr 28 nr 68 nr 4 nr 1 SEEB INTERNATIONAL BILL OF QUANTITIES AIRPORT ELECTRICAL WORKS NEW TERMINAL PIER ITEM ITEM DESCRIPTION UNIT QUANTITY BILL PART SECTION No. VOLUME 3 4 UNIT RATE (R.O.) (in words) (in figures) SECTION R:

More information

Control and Indicating Equipment

Control and Indicating Equipment VdS Guidelines for Fire Detection and Fire Alarm Systems VdS 2540en Control and Indicating Equipment Requirements and Test Methods VdS 2540en : 2010-12 (02) Publishing house: VdS Schadenverhütung GmbH

More information

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

RVL470. Heating Controller. Building Technologies HVAC Products. Series B 2 522 Heating Controller Series B RVL470 Multifunctional heating controller for use in residential and non-residential buildings; suitable for weather-dependent flow temperature control of heating zones

More information

Combi B Alarm box. Mounting instructions

Combi B Alarm box. Mounting instructions Combi B Alarm box Mounting instructions EN Mounting instructions Alarm box Combi B VdS, G113064, G113065, G113066 Table of Contents 1 Description... 3 2 System overview... 3 3 Structure... 3 3.1 Power

More information

SYSTEM MONITORING Locally and remotely

SYSTEM MONITORING Locally and remotely StecaGrid 300 StecaGrid 500 StecaGrid 2000+ StecaGrid 2010+ StecaGrid 2020 StecaGrid 3000 StecaGrid StecaGrid 4200 StecaGrid StecaGrid 10000+ 3ph StecaGrid 8000 3ph StecaGrid 10000 3ph monitoring StecaGrid

More information

SECTION 16720 - FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

SECTION 16720 - FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines PART 1 -- GENERAL 1.1 WORK OF THIS SECTION SECTION 16720 - City of San Diego, CWP Guidelines A. The WORK of this Section includes providing manual and automatic fire alarm and smoke detection systems meeting

More information

ACTIVE 5 ENGINEERING MANUAL

ACTIVE 5 ENGINEERING MANUAL ACTIVE 5 ENGINEERING MANUAL C & K Systems Ltd C031-066 Issue 3 THE ACTIVE 5 INSTALLATION MANUAL. Date: Feb 1997 INTRODUCTION. The Active 5 is a microprocessor controlled intruder alarm panel. It features

More information

500r+ Installation and User Guide

500r+ Installation and User Guide 500r+ Installation and User Guide Compatible Equipment 502rUK-50 Watch/Pendant PA. 509rUK-50 Smoke Detector 515rUK-00 10 metre passive infra red movement detector. 525rUK-00 Remote Set/Unset (Full and

More information

Fire Alarm Control Panel. Family. Operating Manual

Fire Alarm Control Panel. Family. Operating Manual Fire Alarm Control Panel Family Operating Manual CONTENTS System Description AH-03312 System Characteristics... Fire Signal Receiving Board Description-4L... Fire Signal Receiving Board Description-8L...

More information

WATER LEAK DETECTION SYSTEM WLDS-10 INSTALLATION & COMMISSIONING

WATER LEAK DETECTION SYSTEM WLDS-10 INSTALLATION & COMMISSIONING WATER LEAK DETECTION SYSTEM WLDS-10 INSTALLATION & COMMISSIONING DESCRIPTION: An electronic control panel used in conjunction with one pulse meter (water meter with pulse output proportional to flow rate)

More information

BS 7 SIS Safety Information System Green Light for Your Production

BS 7 SIS Safety Information System Green Light for Your Production BS 7 SIS Safety Information System Green Light for Your Production SIS - GreCon Safety Information System The Challenge The Solution In big industrial plants, such as wood based panel productions, there

More information

VM-3000 Series. With new features! Integrated Voice Evacuation System. sound without compromise. www.toa.eu

VM-3000 Series. With new features! Integrated Voice Evacuation System. sound without compromise. www.toa.eu VM-3000 Series Integrated Voice Evacuation System With new features! sound without compromise www.toa.eu SECURITY WITH CONVICTION Continuously TOA brings the knowledge gained from years of experience in

More information

Servo Info and Centering

Servo Info and Centering Info and Centering A servo is a mechanical motorized device that can be instructed to move the output shaft attached to a servo wheel or arm to a specified position. Inside the servo box is a DC motor

More information

Programming made easy. talento plus

Programming made easy. talento plus Technical specifications and other information are subject to change without notice. 82.01.1271.7 Programming made easy. Grässlin GmbH Bundesstraße 36 D-78112 St. Georgen Germany Phone: +49 (0) 7724 /

More information

Quantec Wiring Instructions

Quantec Wiring Instructions Approved Document No. DNUQ777 Rev Quantec Wiring Instructions GENERAL Quantec can be compared to a very sophisticated analogue addressable fire alarm system where the integrity of the wiring is of paramount

More information

The Benefits of ADDRESSABLE Fire Alarm Technology

The Benefits of ADDRESSABLE Fire Alarm Technology The Benefits of ADDRESSABLE Fire Alarm Technology NOTICE: If you were born after 1990 or if you lived through the 60 s and can t remember what happened since, you may be surprised to learn that fire alarm

More information

INSTALLATION MANUAL PC2525. Version 1.1

INSTALLATION MANUAL PC2525. Version 1.1 INSTALLATION MANUAL PC2525 Version 1.1 TABLE OF CONTENTS FEATURES 1 SPECIFICATIONS 1 INSTALLATION 2 Mounting the Panel... 2 Mounting the Keypad... 2 Auxiliary Power Connection... 2 Bell/Siren Connection...

More information

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02 IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02 TABLE OF CONTENTS DESCRIPTION 2 MOUNTING INSTRUCTIONS 2 HOW TO CABLE THE IPX 2/3 POWER SUPPLY INSTALLATION 3 OPERATION 3 CARE

More information

Intelligent chart recorder for compressed air and gases. Measurement - control - indication - alarm - recording - evaluation

Intelligent chart recorder for compressed air and gases. Measurement - control - indication - alarm - recording - evaluation DS 500 Intelligent chart recorder for compressed air and gases Measurement - control - indication - alarm - recording - evaluation new Advantages at a glance: Clear layout: 7" colour screen with touch

More information

AN-3 SEVEN KEY CONSIDERATIONS BEFORE YOU START YOUR SLIC OR FXS PHONE LINE INTERFACE DESIGN

AN-3 SEVEN KEY CONSIDERATIONS BEFORE YOU START YOUR SLIC OR FXS PHONE LINE INTERFACE DESIGN AN-3 SEVEN KEY CONSIDERATIONS BEFORE YOU START YOUR SLIC OR FXS PHONE LINE INTERFACE DESIGN By Joe Randolph Introduction The conventional 2-wire analog phone line that telephone companies provide to residential

More information

Using your LED Plus keypad

Using your LED Plus keypad Using your LED Plus keypad System 238 System 2316 System 238i System 2316i Part Number 5-051-372-00 Rev B Thank you for purchasing this C&K alarm system Your system is one of the most powerful and advanced

More information

TELIKOU Intercom System. TM-200 Main Station. Instruction Manual

TELIKOU Intercom System. TM-200 Main Station. Instruction Manual Intercom System TM-200 Main Station Instruction Manual TELIKOU Systems All Rights Reserved I. Introduction Thank you for choosing TELIKOU intercom product. TM-200 main station is suitable for television

More information

TOTALLY SOLID STATE NON-DIRECTIONAL RADIO BEACONS 190-535 khz

TOTALLY SOLID STATE NON-DIRECTIONAL RADIO BEACONS 190-535 khz TOTALLY SOLID STATE NON-DIRECTIONAL RADIO S 190-535 khz This family of radio transmitters has been developed as extremely efficient, highly reliable Non Directional Beacons. ND2000A/4000A» MODULAR CONSTRUCTION»

More information

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D 7000/7000C/7020 Multi-instrument 4921210109D Features Measurements All 3-phase AC measurements True RMS Replaces analogue meters Demand on each phase current Accuracy U, I and F class 0.5 Other values

More information

USER MANUAL CHARGING STATIONS FOR ELECTRIC VEHICLES

USER MANUAL CHARGING STATIONS FOR ELECTRIC VEHICLES USER MANUAL CHARGING STATIONS FOR ELECTRIC VEHICLES 204.CAxxx 204.CBxxx 204.UBxxx 204.WBxxx MP36289 1 ZP90856-GB-6 INDICE 1 SYSTEM DESCRIPTION... 4 1.1 MODES OF OPERATION... 4 2 USER INTERFACE... 6 2.1

More information

Multi-Protocol decoder 76 200 with Load regulation

Multi-Protocol decoder 76 200 with Load regulation Multi-Protocol decoder 76 2 with Load regulation For locomotives with universal motors on digital layouts operating in the DCC and Motorola data format. Features 76 2 Load regulated multi-protocol decoder

More information

TABLE OF CONTENTS FEATURES

TABLE OF CONTENTS FEATURES TABLE OF CONTENTS FEATURES 2 Keypad Programmable... 2 EEPROM Memory... 2 Static/Lightning Protection... 2 Supervision... 2 Operation... 2 SPECIFICATIONS 2 PC1550 Control Panel... 2 PC1500RK Keypad... 2

More information

Speech Dialler Engineering Information

Speech Dialler Engineering Information Speech Dialler Engineering Information Description The Informa is a Speech Dialler for use with intruder alarm systems. When the control panel recognises an alarm it triggers the Informa. The Informa uses

More information

Standard the the Raising

Standard the the Raising Raising the Standard Introduction to BS 5839-1:2013 An Overview of the BS 5839 1:2013 for professionals who are responsible for the provision of fire detection and alarm systems for buildings Agenda Introduction

More information

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases Detector Color Detector transparent with Color Inserts FAA 500 TR W Trim Ring FAA 500 TR P Trim Ring transparent with Color Inserts FAA 500 BB Ceiling Mount Back Box FCA 500 / FCA 500 E Detector Bases

More information

Global System Technology(UK) PLC The Intelligent Solution

Global System Technology(UK) PLC The Intelligent Solution Global System Technology(UK) PLC The Intelligent Solution MANUFACTURED IN ACCORDANCE WITH Intelligent Photoelectric Smoke Detector Aesthetically pleasing Low profile design 8 Bit intelligent processor

More information

PASSIVE INFRARED INTRUSION DETECTOR PASSIVE INFRAROOD DETECTOR DETECTEUR D INTRUSION PASSIF INFRAROUGE

PASSIVE INFRARED INTRUSION DETECTOR PASSIVE INFRAROOD DETECTOR DETECTEUR D INTRUSION PASSIF INFRAROUGE MODEL HAA51 PASSIVE INFRARED INTRUSION DETECTOR PASSIVE INFRAROOD DETECTOR DETECTEUR D INTRUSION PASSIF INFRAROUGE OPERATING MANUAL HAA51 PASSIVE INFRARED INTRUDER DETECTOR INTRODUCTION HAA51 Passive Infrared

More information