Upon completion of this unit of study, the student should be able to:

Size: px
Start display at page:

Download "Upon completion of this unit of study, the student should be able to:"

Transcription

1

2

3 UNIT OBJECTIVES Upon completion of this unit of study, the student should be able to: 1. Identify supervisory alarm equipment and demonstrate action to take upon receipt of an alarm according to local operating conditions. 2. Identify the various types of detection devices used in fire detection systems. 3. Identify the components of an automatic sprinkler system and their functions. 4. Identify the major sprinkler systems and describe their operation. 5. Identify the actions required for fire department support of an automatic sprinkler system. 6. Connect a fire department pumper to the fire department connection for a sprinkler system. 7. Demonstrate the procedure to temporarily stop the flow of water from a sprinkler head. 8. Identify and demonstrate the procedures for inspecting an automatic sprinkler system in order to determine the systems state of readiness. Fire Detection, Alarm, & Suppression Systems - 1

4 NFPA STANDARDS Successful completion of the information in this section is necessary to fulfill the requirements of the following sections of NFPA : Fire Fighter I Standard Conserve property as a member of a team, given salvage tools and equipment and an assignment, so that the building and its contents are protected from further damage. (A) Requisite Knowledge. The purpose of property conservation and its value to the public, methods used to protect property, types of and uses for salvage covers, operations at properties protected with automatic sprinklers, how to stop the flow of water from an automatic sprinkler head, identification of the main control valve on an automatic sprinkler system, and forcible entry issues related to salvage. (B) Requisite Skills. The ability to cluster furniture; deploy covering materials; roll and fold salvage covers for reuse; construct water chutes and catch-alls; remove water; cover building openings, including doors, windows, floor openings, and roof openings; separate, remove, and relocate charred material to a safe location while protecting the area of origin for cause determination; stop the flow of water from a sprinkler with sprinkler wedges or stoppers; and operate a main control valve on an automatic sprinkler system. Fire Fighter II Standard 6.5.3* Prepare a preincident survey, given forms, necessary tools, and an assignment, so that all required occupancy information is recorded, items of concern are noted, and accurate sketches or diagrams are prepared. (A) Requisite Knowledge. The sources of water supply for fire protection; the fundamentals of fire suppression and detection systems; common symbols used in diagramming construction features, utilities, hazards, and fire protection systems; departmental requirements for a preincident survey and form completion; and the importance of accurate diagrams. (B) Requisite Skills. The ability to identify the components of fire suppression and detection systems; sketch the site, buildings, and special features; detect hazards and special considerations to include in the preincident sketch; and complete all related departmental forms. 2 - Fire Detection, Alarm, & Suppression Systems

5 I. Fire Detection, Alarm, and Suppression Systems A. Fire detection, alarm, and suppression systems are installed to: 1. Notify occupants to escape a fire 2. Summon emergency responders 3. Initiate fire control and suppression systems and sound an alarm 4. Supervise suppression systems for operational status 5. Initiate environmental and utility controls B. Fire fighters must understand the various types of fire protection systems which may be encountered in different occupancies and 1. How these systems function 2. Their role when these systems function in an emergency II. Types of Alarm Systems (Essentials p. 826) A. Protected premises fire alarm systems 1. Also known as "local warning systems" 2. Designed to be initiated manually by pull stations 3. Installed in small schools and public properties 4. Designed to only alert the building's occupants Fire Detection, Alarm, & Suppression Systems - 3

6 5. Does not notify the fire department 6. Automatic detection devices may be added to the system to detect a fire and initiate the signal B. Heat detectors 1. Respond to the thermal energy of a fire a. Typically the slowest type of system to activate b. Activate at a predetermined temperature or when a specified temperature rate of rise occurs c. Used in areas unoccupied or environmentally unsuitable for application of smoke detectors d. Typically used as a property protection device 2. Fixed temperature heat detectors a. Activate when heated to the rated temperature, usually 135 o F or higher b. In a large area, a fire could burn for some time without activating a fixed-temperature detector c. Fusible devices/frangible bulbs (1) Operate identically to fusible links or frangible bulbs used in automatic sprinkler systems (2) To restore a fusible device/frangible bulb detector, the entire detector must be replaced 4 - Fire Detection, Alarm, & Suppression Systems

7 (3) Many of these devices are still in service, however, they are no longer manufactured (4) A fusible device is held in place with solder with known melting (fusing) temperature (5) When the temperature rises to the fusing temperature, the solder melts, and a spring closes the contact points (6) The action completes the circuit and initiates the alarm signal (7) A frangible bulb holds the electrical contacts apart like a fusible link does (8) The bulb is a small glass vial containing a liquid with a small air bubble (9) When the rated temperature is reached, the bulb fractures and falls out and the contacts complete the circuit to initiate the alarm d. Continuous line detector (1) Designed to detect heat over a linear area parallel to the detector (2) Used to protect long cable channels (3) One type is a cable with a conductive metal inner core sheathed in stainless steel tubing (a) The core and sheathing are separated by an insulating material Fire Detection, Alarm, & Suppression Systems - 5

8 (b) At a predetermined temperature, the insulation loses some of its electrical resistance (c) The current flow between the core and sheathing increases and initiates the alarm (4) Another system uses two insulated wires with an outer covering (a) When the rated temperature is reached, the insulation melts and the wires touch (b) The circuit is then completed and the alarm initiated e. Bimetallic element detector (1) Uses two metals with different heat expansion rates (2) When heated, one metal expands faster, causing the strip to bend (3) The deflection makes or breaks the circuit causing alarm activation (4) Most bimetallic detector reset automatically when cooled 3. Rate-of-rise heat detectors a. Operates on the assumption that the temperature from a fire will increase faster than normal atmospheric heating b. Designed to operate when the temperature rise exceeds 12 o F to 15 o F in one minute 6 - Fire Detection, Alarm, & Suppression Systems

9 c. Most are reliable and not subject to false activations d. Automatically reset if undamaged e. Pneumatic rate-of-rise spot detector (1) Most common type of rate-of-rise detector used (2) Consists of a dome-shaped air chamber with a flexible metal diaphragm in the base (3) A small hole allows air to enter and exit the chamber during normal temperature changes (4) During a fire, the air in the chamber expands faster than it can escape (5) The expansion causes the pressure in the chamber to increase and forces the metal diaphragm against the contact points, initiating the alarm f. Rate-compensated detector (1) Consists of an outer metallic sleeve housing two bowed struts with slower expansion rates than the sleeve (2) When heated rapidly, the outer sleeve expands in length (3) The tension is reduced on the inner strips causing the contacts to come together Fire Detection, Alarm, & Suppression Systems - 7

10 C. Smoke detectors/alarms 1. Smoke detectors a. Typically installed in nonresidential and multifamily occupancies b. Detect smoke and transmit a signal to another device that sounds the alarm 2. Smoke alarms a. Installed in single-family dwellings b. Self-contained unit capable of detecting smoke and sounding an alarm 3. Photoelectric smoke detectors a. Also called a "visible products-of-combustion detector" b. Use a photoelectric cell coupled with a small light source c. Generally more sensitive to smoldering fires than ionization detectors d. Beam application type (1) A beam of light is focused onto a photoelectric cell which converts the beam into an electric current (2) When smoke obscures the light beam, the amount of current is reduced and an alarm sounds 8 - Fire Detection, Alarm, & Suppression Systems

11 e. Refractory photocell type (1) A light beam passes through a small chamber away from the light source (2) The light does not strike the photocell and no current is produced (3) When smoke enters the chamber, the light beam is refracted in all directions and strikes the photocell, activating the alarm 4. Ionization smoke detectors a. Tiny particles and aerosols are produced during combustion b. These particles can be detected by devices using a small amount of radioactive material to ionize air molecules as they enter the detector c. The ionized air particles allow an electrical current to flow between plates in the ionization chamber d. When smoke enters the chamber, its particles attach to the air ions making the air less conductive e. The decrease in current activates the alarm D. Flame detectors 1. Reacts the fastest to fire a. Prone to activation by sunlight, welding and other bright lights Fire Detection, Alarm, & Suppression Systems - 9

12 b. Usually positioned where other light sources are unlikely c. Must have an unobstructed view of the protected area d. Used where immediate reaction is necessary such as flammable liquid manufacturing and dispensing facilities 2. Infrared detectors a. Sensitive to sunlight and usually installed in fully enclosed areas b. Most are designed to require flickering motion of flame to activate 3. Ultraviolet detectors a. Virtually insensitive to sunlight b. Not suitable when arc welding is done E. Fire-gas detectors 1. Used to detect the gases produced by a fire in a confined space 2. The gases produced will vary depending on the chemical makeup of the burning fuel 3. Will initiate an alarm more quickly than a heat detector but slower than a smoke detector 4. Can be designed to be sensitive only to those gases produced by a hostile fire and ignore those produced by a friendly fire in an industrial operation 10 - Fire Detection, Alarm, & Suppression Systems

13 F. 5. Fire fighters will encounter very few fire-gas detectors except in special occupancies Combination detectors: makes detectors more responsive to fire conditions 1. Fixed temperature/rate-of-rise heat detectors 2. Smoke/heat detectors 3. Smoke/fire-gas detectors G. Detectors have a variety of audible and visual indicating devices H. Fire department response to heat/smoke alarm calls 1. Normally a full structure fire response is dispatched to the location of a activated smoke or heat alarm 2. If there are no signs of smoke or fire when they arrive, a fire fighter with a portable radio should go to the alarm control panel to silence the alarm so it can be further investigated 3. The system must not be reset or turned off until fire fighters determine the cause of the alarm 4. The individual assigned to the alarm panel must remain and monitor the panel in case of another alarm 5. If a second alarm sounds, the Incident Commander should be immediately notified 6. The system can be reset after the source of the alarm is determined and stabilized Fire Detection, Alarm, & Suppression Systems - 11

14 III. Automatic Alarm Signaling Systems (Essentials p. 837) A. Fire codes or insurance companies may require an occupancy to have an alarm system which transmits a signal off site to summon help B. Auxiliary systems 1. Local energy systems: used only in communities with municipal fire alarm box systems a. An occupancy's alarm system is directly connected to the municipal master alarm box b. When the occupancy's alarm activates, it trips the alarm box to which it is attached and transmits the alarm to the alarm center 2. Shunt systems where the municipal alarm circuit extends ("is shunted") into the protected property 3. Parallel telephone systems a. Do not connect to the municipal alarm system b. Transmits the alarm over municipally controlled telephone circuits, which are not used for any other purpose C. Remote station systems 1. Connected directly to the public dispatch center or other approved answering service 2. Usually connected over leased telephone lines 3. Common where central station systems are not available 12 - Fire Detection, Alarm, & Suppression Systems

15 D. Proprietary alarm systems 1. Used for large commercial and industrial buildings, high rises, and commonly owned facilities in a single location (campus or industrial complex) 2. Have a central alarm receiving point on the property that is constantly staffed by trained personnel 3. Alarms are transmitted to a supervising stations where operators can call the fire department or the fire department is automatically notified E. Central station alarm systems 1. Typically a company that sells alarm services to individual customers at different properties 2. Connected to protected properties by dedicated phone lines or radio transmitter 3. When an alarm is received, central station employees initiate an appropriate emergency response F. Fire alarm systems are designed to be self-supervising 1. A distinct trouble signal is generated anytime the system is not operating normally, such as when: a. A utility power outage occurs and the system switches to battery power b. A break in a detector or notification circuit occurs 2. Older systems use closed, supervised circuits where a tiny current always flows Fire Detection, Alarm, & Suppression Systems - 13

16 3. Newer systems microprocessors do an internal diagnostic system test at specified intervals 4. Alarm signals must be distinctively different from trouble signals 5. Some fixed suppression systems depend on a signal from a manual pull station or an automatic detection device to activate 6. Alarm systems must also be "addressable," indicating the location of an activated detector or pull station or a trouble signal G. Auxiliary services interconnected with alarm systems 1. Modern alarm systems may incorporate environmental controls, security, and personnel access controls 2. These auxiliary services may include: a. Shutting down HVAC systems for smoke control b. Closing smoke or fire-rated doors and dampers c. Increasing air pressure in stairwells to exclude smoke from means of egress d. Overriding elevator controls e. Monitoring refrigeration systems and coldstorage areas f. Controlling personnel access to restricted areas g. Detecting combustible or toxic gases 14 - Fire Detection, Alarm, & Suppression Systems

17 IV. Sprinkler Systems (Essentials p. 842) A. Consists of a series of sprinkler heads (sprinklers) arranged to automatically apply water directly on a fire to either extinguish it or control it until fire fighters arrive 1. NFPA Standards set minimum guidelines for: a. Spacing of sprinklers b. Size of piping to be used c. Methods for hanging piping d. Minimum design area per sprinkler e. Installation details 2. General types a. Complete system: protects an entire building b. Partial system: protects only certain areas, such as high hazard areas and exit routes B. Factors affecting sprinkler system reliability and performance: 1. Partially or completely closed valves 2. Poor or improper maintenance 3. Improper design 4. Hazards of the occupancy 5. Distribution obstructions Fire Detection, Alarm, & Suppression Systems - 15

18 6. Deficient water supply 7. Partial sprinkler protection 8. Frozen or broken pipes 9. Damaged or painted sprinkler heads 10. Tampering or vandalism C. Properly operating sprinkler systems: 1. Improve the life safety of a building's occupants by applying water when a fire is relatively small 2. Prevent vertical fire spread in multistory buildings 3. Protect occupants in other parts of a building from fire spread D. Sprinklers alone may not be as effective if: 1. Fires are too small to activate the sprinkler system 2. Smoke reaches the occupants before the system activates 3. Sleeping, intoxicated, or handicapped people occupy the building E. Sprinkler system components 1. Water supply a. Public water supply b. Gravity tanks c. Fire pumps 16 - Fire Detection, Alarm, & Suppression Systems

19 2. Basic piping a. Supply main b. Riser: larger vertical piping c. Feed main: connects riser to cross mains d. Cross mains: services branch lines e. Branch lines: smaller piping on which sprinklers are installed 3. Sprinkler heads a. Parts (1) Valve cap (2) Frame arms (3) Deflector (4) Toggle joint (5) Lever arms (6) Fusible link b. Temperature ratings: may be identified by colorcoded frame arms, colored liquid, or temperature stamped into the head (1) Fusible link sprinkler heads (a) 135 o to 170 o : uncolored or black (b) 175 o to 225 o : white Fire Detection, Alarm, & Suppression Systems - 17

20 (c) 250 o to 300 o : blue (d) 325 o to 375 o : red (2) Frangible bulb heads (a) 135 o to 170 o : orange or red glass bulb (b) 175 o to 225 o : yellow or green bulb (c) 250 o to 300 o : blue bulb (d) 325 o to 375 o : purple bulb c. Release mechanisms (1) Fusible-link (2) Chemical pellet (3) Frangible bulb (4) Quick-response: has a specially designed fusible link with an increased surface area d. Fusible link sprinkler head operation (1) Two lever arms press against the frame arms and valve cap to hold back the water (2) The fusible link holds the levers together (3) The link melts or fuses when exposed to heat and the water pushes the levers and cap out of the way (4) Water strikes the deflector and becomes a spray 18 - Fire Detection, Alarm, & Suppression Systems

21 e. Frangible bulb sprinkler head operation (1) The bulb filled with liquid and a bubble holds the orifice shut (2) Heat expands the liquid until the bubble is absorbed by the liquid (3) The increase in internal pressure shatters the bulb and the orifice opens (4) Water strikes the deflector and becomes a spray f. Chemical pellet sprinklers (1) A pellet of solder, under compression, within a small cylinder, melts at a predetermined temperature (2) A plunger then moves down and releases the valve cap g. Sprinkler head position (1) Pendant: extends down from the underside of the piping (2) Upright: sits on top of the piping (3) Sidewall: extends from the side of the pipe and has a special deflector to create a fanshaped pattern (4) Special purpose (a) Corrosive-resistant coated (b) Recessed Fire Detection, Alarm, & Suppression Systems - 19

22 4. Sprinkler head storage a. A storage cabinet for extra heads and a wrench should be installed near the sprinkler system b. Normally holds minimum of six extra heads 5. Control indicator valves a. Located between water source and sprinkler system to shut off water supply b. Indicating valves visually show if opened or closed c. Outside screw and yoke (OS&Y) (1) Has a yoke on the outside with a threaded stem which controls the opening and closing of the valve gate (2) Threaded stem is out of yoke when open d. Post indicator valve (PIV) (1) Valve stem inside of hollow post (2) Has small window on post where "OPEN" or "SHUT" is displayed e. Wall post indicator valve (WPIV) - similar to PIV but extends through wall f. Post indicator valve assembly (PIVA) (1) Does not have the small window and words (2) Has a sight area that is open when the valve is open 20 - Fire Detection, Alarm, & Suppression Systems

23 6. Operating valves a. Alarm test valve: simulates activation of the system b. Inspector's test valve: equipped with a same size opening as a sprinkler head to simulate activation of a head c. Main drain valve: to drain water from the system for maintenance 7. Water flow alarms a. Hydraulically operated: to alert occupants and a passerby that water is flowing through the system b. Electrically operated: to alert occupants and transmits an alarm when water is flowing through the system 8. Fire department connection (FDC) a. Usually a clappered siamese with at least two 2 1 / 2 -inch female connections b. A check valve is located between the fire department connection and the system to prevent water from the system flowing into the FDC c. Fire department support (1) Supply pumper should have a capacity of at least 1,000 gpm (2) Using same water main as that supplying system will rob the sprinkler system of water Fire Detection, Alarm, & Suppression Systems - 21

24 (3) A minimum of two 2 1 / 2 -inch or larger lines should be attached to the FDC (4) Most sprinkler systems are supplied at 150 psi E. Types of sprinkler systems (Essentials p. 852) 1. Wet pipe systems a. Used in locations not subject to freezing b. Contain water under pressure at all times c. Sprinkler heads will discharge water immediately on activation d. Usually equipped with an alarm check valve on the main riser e. Newer systems may have a backflow prevention check valve and electronic flow alarm instead of an alarm check valve ("straight stick systems") f. Maybe equipped with a retard chamber g. Gauges (1) Designed to catch excess water that may come through the alarm valve in a water pressure surge (2) Reduces chances of false alarms (1) Installed above and below each alarm check valve 22 - Fire Detection, Alarm, & Suppression Systems

25 (2) Riser pressure gauge showing pressure in system (3) Owner or owner's representative should check and record monthly to ensure normal water supply pressure 2. Dry pipe systems a. Used in locations where piping may be subjected to freezing temperatures b. System contains air under pressure instead of water (1) When a sprinkler head opens, air leaves piping and dry-pipe valve automatically opens to fill the system with water c. Gauges (2) Designed with a dry-pipe valve so that a small amount of air pressure holds the valve closed over the water pressure on other side (1) One gauge on the water side and another gauge on the air side of dry pipe valve and at the air pump supplying air (2) Owner or owner's representative should check and record gauge readings weekly to ensure normal air and water pressures are being maintained 3. Preaction sprinkler systems a. Used in properties where it is important to prevent water damage, even if pipes are broken Fire Detection, Alarm, & Suppression Systems - 23

26 b. System pipes are dry until water is released into system in response to detectors c. Uses a deluge type valve, fire detection devices, and closed sprinkler heads d. The operation of detectors releases water into the system and sounds an alarm e. Sprinkler heads open only from functioning of fusible links 4. Deluge system systems a. Used to protect extra hazardous occupancies b. All sprinklers heads are always open (1) System activated by flame or heat detectors (2) When system activates, water flows from all sprinkler heads 5. Residential sprinkler systems a. Used to prevent fire involvement in area of origin and allow occupants to escape b. Typically equipped with quick-response sprinkler heads c. May be wet or dry system d. Components (1) May use plastic or steel piping (2) Must have a pressure gauge, flow detector, and means for draining system 24 - Fire Detection, Alarm, & Suppression Systems

27 F. Fire department operations with sprinkler systems 1. Whenever possible, pumpers supplying hose streams should operate from mains other than that supplying system 2. Control valves should not be closed until fire has been extinguished unless the incident commander determines need to prevent further damage 3. If control valve is closed, a fire fighter should be stationed at valve with a radio to officer-in-charge in case the valve needs to be reopened 4. Fire department personnel should not service system components or restore a system to service due to the potential liability 5. Restoring the system to service should be done by representatives of the owners or occupants or a commercial sprinkler service company 6. Control of water flow from sprinkler heads a. Remove sprinkler wedge or clamp from apparatus b. Raise ladder under activated head c. Climb ladder d. Insert wedge or clamp into flowing head e. Gently tap wedge into place to stop flow Fire Detection, Alarm, & Suppression Systems - 25

28 V. Standpipe Systems A. Allow connection of hoses on various levels of a structure to avoid carrying hoselines up several levels B. Components 1. Fire department connection: usually a clappered siamese with at least two 2 1 / 2 -inch male connections 2. Piping 3. Interior fire department valves and connections C. Class I standpipe: have 2 1 / 2 -inch hose connections for use by fire fighters D. Class II standpipe 1. Have 1 1 / 2 -inch single jacket linen hose with a lightweight nozzle attached 2. Designed for use by building occupants with no fire training 3. Most have been taken out of service E. Class III standpipe 1. Have 2 1 / 2 -inch hose connections and 1 1 / 2 inch single jacket linen hose with a lightweight nozzle attached 2. Designed for use by building occupants or fire fighters 26 - Fire Detection, Alarm, & Suppression Systems

29 VI. Fire Detection, Alarm, and Suppression Systems Summary A. Fire fighters are likely to encounter detection and/or suppression systems in many commercial occupancies and must be familiar with their operations B. Personnel have to understand their role in dealing with detection and alarm system activations and always keep in mind that a sounding alarm should not be taken lightly C. Sprinkler systems have the capacity to control small fires in early stages but should not be depended on to completely control every fire Fire Detection, Alarm, & Suppression Systems - 27

30 FIRE DETECTION, ALARM, & SUPPRESSION SYSTEMS QUIZ Name: Date: 1. Which private fire alarm signaling system is designed to only notify the occupants within the protected premises of a fire? a. Central station system b. Remote station system c. Proprietary system d. Protected premises fire alarm system 2. Which private fire alarm signaling system is designed to transmit alarms to a commercial company which then sends the alarms to the fire department? a. Central station system b. Remote station system c. Proprietary system d. Protected premises fire alarm system 3. Which private fire alarm signaling system is designed to usually protect large plants or complexes and has a supervising station to monitor the system? a. Central station system b. Remote station system c. Proprietary system d. Protected premises fire alarm system 4. Which type of detectors are typically the slowest to respond when a fire occurs? a. Heat detectors b. Smoke detectors c. Flame detectors d. Fire-gas detectors 5. Which is the most common smoke detector used by consumers and is designed to activate when the invisible products of combustion are detected by a radioactive material in the detector? a. Ionization detector b. Photoelectric detector c. Fixed temperature detector d. Rate-of-rise detector 28 - Fire Detection, Alarm, & Suppression Systems

31 FIRE DETECTION, ALARM, & SUPPRESSION SYSTEMS QUIZ 6. A sprinkler system is designed to be used in areas where freezing is likely to occur. a. Wet pipe b. Dry pipe c. Quick response d. Dry response 7. Which of the following factors affect sprinkler system reliability and performance? a. Partially or completely closed valves b. Poor or improper main c. Distribution obstructions d. All of the above 8. The smaller piping on which sprinklers are installed are known as the. a. Risers b. Feed main c. Branch lines d. Cross mains 9. On which of the following sprinkler system valves is a threaded stem extended from the valve when it is open? a. Post indicator valve b. Outside screw and yoke c. Post indicator valve assembly d. Wall post indicator valve 10. Which of the following sprinkler systems is used to protect extra hazardous occupancies with all sprinklers heads always open? a. Preaction b. Dry pipe c. Quick response d. Deluge Fire Detection, Alarm, & Suppression Systems - 29

32 INSTRUCTOR'S GUIDE PRACTICAL SKILLS These Lead Instructor Practical Skills are designed to provide the Lead Instructor for a Fire Fighter I and II course with a more detailed overview of the practical skills required of all students. The appropriate skills from NFPA are listed at the front of each skill's section. Although the skills from NFPA are written as Job Performance Requirements, these have been divided into individual skill elements. This is to allow for consistency in the evaluation of each skill element. Students must successfully complete each step of each practical skill during the practical skills evaluation portion of a Fire Fighter I and II course. At the time of a Fire Fighter I and II Certification Examination, the skill steps have been prioritized to allow a student to miss a predetermined number of steps. Fire Detection, Alarm, & Suppression Systems - 31

33 MISSOURI DIVISION OF FIRE SAFETY FIRE FIGHTER I & II PRACTICAL SKILLS Fire Detection, Alarm, & Suppression Systems Successful completion of the practical skills in this section are necessary to fulfill the requirements of the following sections of NFPA : Fire Fighter I Standard Conserve property as a member of a team, given salvage tools and equipment and an assignment, so that the building and its contents are protected from further damage Fire Detection, Alarm, & Suppression Systems

34 MISSOURI DIVISION OF FIRE SAFETY FIRE FIGHTER I & II PRACTICAL SKILLS Fire Suppression Systems - NFPA , Demonstrate Connecting to a Fire Department Connection Sill Objective: The candidate, given a supply of 2 1 / 2 " or 3" hose in an apparatus hose bed, shall connect two 50' sections of hose to a fire department sprinkler connection and the apparatus. The candidate shall then identify the normal minimum water pressure that should be applied to the sprinkler system. Students are allowed two chances at each skill for successful completion. Any step listed in italics missed shall result in failure of the skill. Otherwise, students are allowed to miss a maximum of one of the following steps and pass this skill. Items to be checked If the candidate 1. First, obtains necessary tools and equipment such as two spanner wrenches 2. Wears gloves during the skill 3. Removes 50 feet of hose from the hose bed neatly and in organized fashion 4. Connects female coupling to fire apparatus discharge 5. Connects male coupling to fire department sprinkler connection 6. Repeats steps 3, 4, & 5 7. Arranges all hose in an orderly fashion 8. Identifies that water pressure in hose lines should be a minimum of 150 psi Fire Detection, Alarm, & Suppression Systems - 33

Fire detection, alarm, and suppression systems are installed to:

Fire detection, alarm, and suppression systems are installed to: Fire detection, alarm, and suppression systems are installed to: Notify occupants to escape a fire Summon emergency responders Initiate suppression systems Supervise suppression systems for operational

More information

Fighting Fire in Sprinklered Buildings. Student Guide

Fighting Fire in Sprinklered Buildings. Student Guide Fighting Fire in Sprinklered Buildings Student Guide Fighting Fire in Sprinklered Buildings Student Guide Table of Contents Purpose........................................................... 3 Instruction

More information

Fire Detection, Protection, and Suppression Systems. Objectives (1 of 5) Objectives (2 of 5) Chapter 36

Fire Detection, Protection, and Suppression Systems. Objectives (1 of 5) Objectives (2 of 5) Chapter 36 Fire Detection, Protection, and Suppression Systems Chapter 36 Objectives (1 of 5) Explain why all firefighters should have a basic understanding of fire protection systems. Describe the basic components

More information

FIVE YEAR CERTIFICATION REPORT

FIVE YEAR CERTIFICATION REPORT GARDEN GROVE FIRE DEPARTMENT FIRE PREVENTION DIVISION FIVE YEAR CERTIFICATION REPORT Service and maintenance report of automatic fire extinguishing systems, including fire sprinklers, dry, deluge, and

More information

FLORIDA ATLANTIC UNIVERSITY FIRE ALARM SYSTEM INSTALLATION MANUAL

FLORIDA ATLANTIC UNIVERSITY FIRE ALARM SYSTEM INSTALLATION MANUAL FLORIDA ATLANTIC UNIVERSITY FIRE ALARM SYSTEM INSTALLATION MANUAL January, 2003 Environmental Health and Safety Florida Atlantic University 777 Glades Rd. Boca Raton, FL 33431 Phone: 561-297-3129 Fax:

More information

INSTRUCTIONS FOR BUILDINGS WITH FIRE PROTECTION EQUIPMENT

INSTRUCTIONS FOR BUILDINGS WITH FIRE PROTECTION EQUIPMENT INSTRUCTIONS FOR BUILDINGS WITH FIRE PROTECTION EQUIPMENT FIRE EXTINGUISHERS,SPRINKLER SYSTEMS AND FIRE ALARMS Attachment #1 Inspection of Fire Extinguishers Fire Extinguishers must be tested according

More information

Firefighter Review. Instructor Guide

Firefighter Review. Instructor Guide Firefighter Review Instructor Guide Session Reference: 3 Topic: Attack Line Handling Level of Instruction: Time Required: Three Hours Materials: Two Fully Equipped Pumpers Structure for Use in Advancing

More information

Fire Alarm System Monitoring - CAN/ULC-S561-03

Fire Alarm System Monitoring - CAN/ULC-S561-03 Fire Alarm System Monitoring - CAN/ULC-S561-03 Brian McBain ULC Regulatory Services May 4, 2011 Copyright 1995-2007 Underwriters' Laboratories of Canada. All rights reserved. No portion of this material

More information

Module 5. Fire and Emergency Alarm System Part I- Basics

Module 5. Fire and Emergency Alarm System Part I- Basics Module 5 Fire and Emergency Alarm System Part I- Basics 1 This module will describe: 1. Components and the arrangements of components in fire and emergency alarm systems. 2. How these systems work. 3.

More information

CBD-233. Fire Alarm and Detection Systems

CBD-233. Fire Alarm and Detection Systems Page 1 of 5 CBD-233. Fire Alarm and Detection Systems Originally published August 1984. R.H.L. McEwen Fire alarm systems are normally required by building codes. In the case of new buildings, this is usually

More information

Fire Alarm System Plans Review Checklist Property location Date of Review

Fire Alarm System Plans Review Checklist Property location Date of Review Fire Alarm System Plans Review Checklist Property location Date of Review 1. Is application completed in entirety? 2. Are the plans review fee submitted with the application? 3. Does floor plan include

More information

Depending on your facility and the equipment contained within, all or part of the checklists/logs can be printed for use.

Depending on your facility and the equipment contained within, all or part of the checklists/logs can be printed for use. Large Facility Fire Safety Checklists and Logs This package contains checklists to ensure that all fire and life safety equipment are properly inspected. There are also logs on which to record the inspections

More information

EFSN Training i Module 1. 90 Minutes

EFSN Training i Module 1. 90 Minutes Introduction to Sprinklers EFSN Training i Module 1 90 Minutes Topics How sprinklers work Performance of sprinkler systems Types of Sprinkler Introduction to sprinkler systems Introduction ti to sprinkler

More information

SELF-INSPECTION PROGRAM FOR FIRE PROTECTION EQUIPMENT

SELF-INSPECTION PROGRAM FOR FIRE PROTECTION EQUIPMENT SELF-INSPECTION PROGRAM FOR FIRE PROTECTION EQUIPMENT INTRODUCTION No matter how reliable fire protection equipment may seem, periodic maintenance is needed to ensure proper operation. Fire protection

More information

General Fire Code Requirements Within Commercial Tenant Spaces

General Fire Code Requirements Within Commercial Tenant Spaces FIRE DEPARTMENT in cooperation with Scope: General Fire Code Requirements Within Commercial Tenant Spaces This handout is designed to assist owners, architects, contractors and others in understanding

More information

HERNANDO COUNTY FIRE ALARM GUIDELINES

HERNANDO COUNTY FIRE ALARM GUIDELINES HERNANDO COUNTY FIRE ALARM GUIDELINES To be used for all commercial building fire alarm system plan review. The procedures set forth in this document are the minimum requirements necessary to ensure a

More information

INSPECTION, TESTING AND MAINTENANCE OF FIRE PROTECTION SYSTEMS AND EQUIPMENT

INSPECTION, TESTING AND MAINTENANCE OF FIRE PROTECTION SYSTEMS AND EQUIPMENT CITY OF SPRING LAKE PARK Code Enforcement Department 1301 81 st Avenue NE Spring Lake Park MN 55432 Business Phone 763-784-6491 Fax 763-792-7257 INSPECTION, TESTING AND MAINTENANCE OF FIRE PROTECTION SYSTEMS

More information

PLAN REVIEW GUIDE FOR FIRE ALARM

PLAN REVIEW GUIDE FOR FIRE ALARM PLAN REVIEW GUIDE FOR FIRE ALARM PROJECT NAME: PERMIT # PROJECT ADDRESS: CONTACT PERSON: PHONE Fire alarm system installation information shall be provided on the appropriate architectural and electrical

More information

Fire Alarm System Standpipes Sprinkler Systems Fire Drills Commercial Cooking Hood and more

Fire Alarm System Standpipes Sprinkler Systems Fire Drills Commercial Cooking Hood and more FIRE PROTECTION SYSTEMS Fire protection systems, measures and equipment are all related to the safety of the occupants and the protection of the property. As part of a building design and its intended

More information

Risk Control Bulletin Inspection, Testing & Maintenance (ITM) of Water-Based Fire Protection Systems

Risk Control Bulletin Inspection, Testing & Maintenance (ITM) of Water-Based Fire Protection Systems Risk Control Bulletin Inspection, Testing & Maintenance (ITM) of Water-Based Fire Protection Systems Introduction Fire protection systems are provided in or at a building to safeguard the lives of building

More information

Winnipeg Fire Department Fire Prevention Branch

Winnipeg Fire Department Fire Prevention Branch Winnipeg Fire Department Fire Prevention Branch Manitoba Fire Code Life-Safety Equipment Maintenance Requirements The Fire Prevention Branch of the Winnipeg Fire Department has prepared this document of

More information

IDENTIFICATION BROCHURE FOR Central RESIDENTIAL WET SPRINKLERS

IDENTIFICATION BROCHURE FOR Central RESIDENTIAL WET SPRINKLERS IDENTIFICATION BROCHURE FOR Central RESIDENTIAL WET SPRINKLERS 1 INTRODUCTION TO THE VOLUNTARY REPLACEMENT PROGRAM This brochure provides information that will assist you in identifying whether the sprinklers

More information

Important Ontario Fire Code Information for Building Owners in the City of Windsor

Important Ontario Fire Code Information for Building Owners in the City of Windsor Important Ontario Fire Code Information for Building Owners in the City of Windsor This information is intended to be used a reference only. For a complete listing consult the Ontario Fire Code or contact

More information

SECTION 16720 - FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

SECTION 16720 - FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines PART 1 -- GENERAL 1.1 WORK OF THIS SECTION SECTION 16720 - City of San Diego, CWP Guidelines A. The WORK of this Section includes providing manual and automatic fire alarm and smoke detection systems meeting

More information

Bold items are particular to the City of Euless

Bold items are particular to the City of Euless EULESS FIRE DEPARTMENT FIRE MARSHAL S OFFICE INFORMATION LINE: Revised 2/12 Fire Chief Wes Rhodes Fire Marshal Paul Smith EFD-FMO 3-2 2009 International Fire & Building Code as Amended NFPA Standards Adopted

More information

Fire Sprinkler Monitoring & Releasing Systems

Fire Sprinkler Monitoring & Releasing Systems Fire Sprinkler Monitoring & Releasing Systems Training Manual Contents Foreword...3 Introduction...4 Glossary/Definitions...5 Symbols...10 Codes and Standards...13 Fire Alarm Signals...15 Types Of Sprinkler

More information

Name Of Occupancy Date. Yes No Describe

Name Of Occupancy Date. Yes No Describe FIRE PREVENTION INSPECTION CHECKLIST For Class A Occupancy (For Assembly Buildings, Bars, Restaurants, Gyms, Churches, Arenas, Theatres or wherever people gather) Name Of Occupancy Date Physical Address

More information

CITY OF PHILADELPHIA DEPARTMENT OF LICENSES AND INSPECTIONS ANNUAL CERTIFICATION FOR FIRE ALARM SYSTEMS

CITY OF PHILADELPHIA DEPARTMENT OF LICENSES AND INSPECTIONS ANNUAL CERTIFICATION FOR FIRE ALARM SYSTEMS CITY OF PHILADELPHIA DEPARTMENT OF LICENSES AND INSPECTIONS ANNUAL CERTIFICATION FOR FIRE ALARM SYSTEMS PROPERTY ADDRESS (BRT Address Required) TESTING CONTRACTOR (Name and Address) License No. ANNUAL

More information

ALBERTA FIRE CODE SAFETY EQUIPMENT MAINTENANCE REQUIREMENTS

ALBERTA FIRE CODE SAFETY EQUIPMENT MAINTENANCE REQUIREMENTS ALBERTA FIRE CODE SAFETY EQUIPMENT MAINTENANCE REQUIREMENTS In this document are the fire safety equipment maintenance requirements that are found in Division B of the Alberta Fire Code (AFC 2006) for

More information

Ionization alarms are best suited for rooms, which contain highly combustible material. These types of material include:

Ionization alarms are best suited for rooms, which contain highly combustible material. These types of material include: Smoke Detector University Most people are aware of the danger of fire but are unaware of the fatality of smoke. More people die from breathing smoke than by burns. In fact, deaths from smoke inhalation

More information

OHIO BOARD OF BUILDING STANDARDS. Smoke Alarms and Fire Safety

OHIO BOARD OF BUILDING STANDARDS. Smoke Alarms and Fire Safety OHIO BOARD OF BUILDING STANDARDS Smoke Alarms and Fire Safety Updated January 2016 2 UNDERSTANDING THE TERMINOLOGY Detector. An initiation device suitable for connection to a circuit that has a sensor

More information

FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS

FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS November 2011, Updated March 2012 COLORADO SPRINGS FIRE DEPARTMENT Division of the Fire Marshal If you have any questions or

More information

PLAN SUBMITTAL REQUIREMENTS FOR SPRAY BOOTHS AND SPRAYING ROOMS EXTINGUISHING SYSTEMS

PLAN SUBMITTAL REQUIREMENTS FOR SPRAY BOOTHS AND SPRAYING ROOMS EXTINGUISHING SYSTEMS January 1997 PLAN SUBMITTAL REQUIREMENTS FOR SPRAY BOOTHS AND SPRAYING ROOMS EXTINGUISHING SYSTEMS 1.0 PERMIT 1.1 After receipt of a Building Permit from the City of San Jose Building Department, submit

More information

FIRE SAFETY ONLINE TRAINING

FIRE SAFETY ONLINE TRAINING INTRODUCTION This Fire Safety Training module is designed to teach you preventive measures that will eliminate or minimize causes of fire or fire hazards in the workplace, and to teach you proper emergency

More information

Sprinkler and Fire Alarm Systems for the Building Official

Sprinkler and Fire Alarm Systems for the Building Official Sprinkler and for the Building Official Randall Kovacs, P.Eng., CP, FEC Gage-Babcock & Associates, Ltd. Topics Coordinated System Testing 1 Wet Dry Pre-action Deluge Wet System: Pipes filled with water

More information

MAINTENANCE AND SERVICE OF AUTOMATIC FIRE EXTINGUISHING SYSTEMS

MAINTENANCE AND SERVICE OF AUTOMATIC FIRE EXTINGUISHING SYSTEMS FIRE DEPARTMENT Bureau of Fire Protection and Life Safety www.cityofsanmateo.org 1900 O Farrell, Suite 140 San Mateo, CA 94403-1332 (650) 522-7940 FAX: (650) 522-7941 TDD: (650) 522-7047 MAINTENANCE AND

More information

NATIONAL FIRE ALARM AND SIGNALING CODE

NATIONAL FIRE ALARM AND SIGNALING CODE GAP.11.1.1.0 A Publication of Global Asset Protection Services LLC NATIONAL FIRE ALARM AND SIGNALING CODE INTRODUCTION National Fire Protection Association (NFPA) documents describe a level of fire protection

More information

FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS November 2011

FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS November 2011 FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS November 2011 COLORADO SPRINGS FIRE DEPARTMENT Division of the Fire Marshal If you have any questions or comments regarding the

More information

FIRE SAFETY SELF-INSPECTION FORM FOR CULTURAL INSTITUTIONS

FIRE SAFETY SELF-INSPECTION FORM FOR CULTURAL INSTITUTIONS FIRE SAFETY SELF-INSPECTION FORM FOR CULTURAL INSTITUTIONS The attached self-inspection form is intended for staff use at regular, frequent intervals. It should not take the place of two other vital measures

More information

Inspection and Testing of Water-Based Systems

Inspection and Testing of Water-Based Systems Inspection and Testing of Water-Based Systems Standard Model/Computer-Based Testing Level III Content Outline The candidate for NICET certification at Level III in the Inspection and Testing of Water-Based

More information

University Design Standard. Fire Alarm Systems

University Design Standard. Fire Alarm Systems University Design Standard Fire Alarm Systems 1.0 Overview This document provides Virginia Tech s standards for the design and installation of fire alarm systems and equipment in new construction, retrofit

More information

Transformer Deluge Systems

Transformer Deluge Systems Transformer Deluge Systems How Do Transformer Fires Ignite? Common causes of transformer failure: Weather-related events such as lightning Short circuits in electrical equipment The most common cause is

More information

SARATOGA FIRE DISTRICT EARLY WARNING FIRE ALARM SYSTEM STANDARDS AND REQUIRMENTS CONTENTS

SARATOGA FIRE DISTRICT EARLY WARNING FIRE ALARM SYSTEM STANDARDS AND REQUIRMENTS CONTENTS SARATOGA FIRE DISTRICT EARLY WARNING FIRE ALARM SYSTEM STANDARDS AND REQUIRMENTS CONTENTS I. APPLICATION AND DEFINITIONS 1.01 Authorization for Standards 1.02 Application of Standards 1.03 Definitions

More information

EXHIBIT A SCOPE OF WORK

EXHIBIT A SCOPE OF WORK EXHIBIT A SCOPE OF WORK 1. (Contractor) shall provide fire alarm system maintenance/repair/testing services as described herein to the California Department of Veterans Affairs (hereinafter CDVA, CalVet,

More information

St. John s University

St. John s University St. John s University Fire Safety Plan Founder s Village Townhouses Page 1 St. John s University Fire Safety Plan Part 1-Building Information Section Founder s Village Townhouses 8000 Utopia Parkway Jamaica

More information

BUILDING OWNERS - SERVICE RELATED ISSUES FOR FIRE ALARM SYSTEMS

BUILDING OWNERS - SERVICE RELATED ISSUES FOR FIRE ALARM SYSTEMS BUILDING OWNERS - SERVICE RELATED ISSUES FOR FIRE ALARM SYSTEMS Owners have numerous responsibilities as it pertains to the maintenance and operation of a building s fire safety equipment. The liabilities

More information

FIRE ALARM SYSTEM CHECKLIST For Addressable Systems PRIOR TO INSPECTION

FIRE ALARM SYSTEM CHECKLIST For Addressable Systems PRIOR TO INSPECTION Building Name/Location: Installing Company: Observation By: Date: Time: 1 Building Occupants, Authorities and Alarm Monitoring Co Have Been Notified 2 FACP Manufacturer and Panel is Approved for NCSU Campus

More information

SPECIFICATIONS FOR THE INSTALLATION OF FIRE ALARM SYSTEMS, SPRINKLER SYSTEMS, AND MASTER BOXES IN THE POQUONNOCK BRIDGE FIRE DISTRICT

SPECIFICATIONS FOR THE INSTALLATION OF FIRE ALARM SYSTEMS, SPRINKLER SYSTEMS, AND MASTER BOXES IN THE POQUONNOCK BRIDGE FIRE DISTRICT SPECIFICATIONS FOR THE INSTALLATION OF FIRE ALARM SYSTEMS, SPRINKLER SYSTEMS, AND MASTER BOXES IN THE POQUONNOCK BRIDGE FIRE DISTRICT The purpose of these specifications is to insure that there are minimum

More information

FACILITY FIRE PREVENTION AND EMERGENCY PREPAREDNESS INSPECTION CHECKLIST

FACILITY FIRE PREVENTION AND EMERGENCY PREPAREDNESS INSPECTION CHECKLIST FACILITY FIRE PREVENTION AND EMERGENCY PREPAREDNESS INSPECTION CHECKLIST Date of Inspection: Conducted by: Location: Reviewed by: Date of Review: Comments or additional corrective action taken as a result

More information

Maintaining Fire Protection Systems

Maintaining Fire Protection Systems Maintaining Fire Protection Systems Fire continues to be a major threat to your business and your personal safety. Each year several thousand people are injured or killed by fires and billions of dollars

More information

Series MJC Multiple Jet Controls DN20, DN25, DN40, and DN50, 12 bar BSPT Inlet & Outlets Threads General Description.

Series MJC Multiple Jet Controls DN20, DN25, DN40, and DN50, 12 bar BSPT Inlet & Outlets Threads General Description. Worldwide Contacts www.tyco-fire.com Series Multiple Jet Controls DN20, DN25, DN40, and DN50, 2 bar BSPT Inlet & Outlets Threads General Description The TYCO Series Multiple Jet Controls are control valves

More information

FIRE SAFETY SELF-INSPECTION FORM FOR CULTURAL INSTITUTIONS. 1. All Floors (inspect from top floor to basement): Yes No

FIRE SAFETY SELF-INSPECTION FORM FOR CULTURAL INSTITUTIONS. 1. All Floors (inspect from top floor to basement): Yes No General Inspection FIRE SAFETY SELF-INSPECTION FORM FOR CULTURAL INSTITUTIONS 1. All Floors (inspect from top floor to basement): Yes are fire exits and directional signs properly illuminated? is the emergency

More information

Attachment 9. Trouble signals. Interfaced equipment. Primary (main) power supply

Attachment 9. Trouble signals. Interfaced equipment. Primary (main) power supply FIRE DETECTION, ALARM AND MASS NOTIFICATION SYSTEMS Inspection, testing, and maintenance of fire detection, alarm and Mass Notification systems shall be performed in accordance with the manufacturer's

More information

Module 4, Lesson 12 Fire Alarm Systems

Module 4, Lesson 12 Fire Alarm Systems Student Manual Module 4, Lesson 12 Fire Alarm Systems Performance Objectives At the conclusion of this lesson, you will be able to: Identify the components and functions of a fire alarm system and determine

More information

CONSTRUCTION FIRE SAFETY PLANNING GUIDELINES

CONSTRUCTION FIRE SAFETY PLANNING GUIDELINES CONSTRUCTION FIRE SAFETY PLANNING GUIDELINES Review the following information pertaining to Construction Fire Safety Planning: B.C. Building Code Sections 8.1 up to and including Subsection 8.2.3 B.C.

More information

Potter Electric Sprinkler Monitoring Training Manual

Potter Electric Sprinkler Monitoring Training Manual R Potter Electric Sprinkler Monitoring Training Manual 1 #8704200D 2 Contents Foreword... 4 Introduction... 5 Fire Alarm Signals... 6 Types Of Sprinkler Systems... 7 Wet Pipe Sprinkler Systems... 8 Straight

More information

Program No. 1.6.1. Section Heading

Program No. 1.6.1. Section Heading ENVIRONMENTAL HEALTH AND SAFETY EHS PROGRAM MANUAL Program Title 1.0 INTRODUCTION The New York City Fire Department (FDNY) is responsible for approving and/or inspecting fire alarm systems, buildings,

More information

Fire Alarm System Plans Submittal Guidelines For New and Existing Systems

Fire Alarm System Plans Submittal Guidelines For New and Existing Systems Fire Alarm System Plans Submittal Guidelines For New and Existing Systems SCOPE The Temecula Fire Prevention Bureau (TFPB) has established the following requirements for the submittal of all fire alarms,

More information

FIRE PROTECTION SYSTEMS ACCEPTANCE INSPECTION AND TESTING PROCEDURE

FIRE PROTECTION SYSTEMS ACCEPTANCE INSPECTION AND TESTING PROCEDURE ACCEPTANCE INSPECTION AND TESTING PROCEDURE Wet Pipe Sprinkler Systems...2 Dry Pipe Sprinkler Systems...2 Clean Agent Fire Extinguishing System...4 Total Flooding Systems...4 Fire Dampers...5 Smoke Dampers...5

More information

FIRE ALARM AND EMERGENCY COMMUNICATION SYSTEM RECORD OF COMPLETION

FIRE ALARM AND EMERGENCY COMMUNICATION SYSTEM RECORD OF COMPLETION FIRE ALARM AND EMERGENCY COMMUNICATION SYSTEM RECORD OF COMPLETION To be completed by the system installation contractor at the time of system acceptance and approval. It shall be permitted to modify this

More information

SMOKE DETECTOR INSTALLATION PROGRAM The Burlington Ordinance Perspective

SMOKE DETECTOR INSTALLATION PROGRAM The Burlington Ordinance Perspective SMOKE DETECTOR INSTALLATION PROGRAM The Burlington Ordinance Perspective The National Fire Alarm Code, NFPA 72, sets the minimum requirements of performance, selection, use and location of automatic detection

More information

City of Bettendorf Fire Alarm System Requirements

City of Bettendorf Fire Alarm System Requirements City of Bettendorf Fire Alarm System Requirements Section 907 of the 2009 Edition of the International Fire Code (IFC) and Section 10-7-3 of the Municipal Code provide fire alarm requirements. IFC Section

More information

EMERGENCY ACTION, EVACUATION AND FIRE PREVENTION SAFETY PROGRAM

EMERGENCY ACTION, EVACUATION AND FIRE PREVENTION SAFETY PROGRAM EMERGENCY ACTION, EVACUATION AND FIRE PREVENTION SAFETY PROGRAM REGULATORY STANDARD: OSHA - 29CFR1910.36-29CFR1910.38-29CFR1910.157-29CFR1910.165 NFPA-10 BASIS: The OSHA Emergency Action Planning and the

More information

LESSON PLAN 4 6-8 FIRE PREVENTION AND SAFETY

LESSON PLAN 4 6-8 FIRE PREVENTION AND SAFETY The Science of Fire-Suppression and Fire-Warning Systems Activity Fire Insurance Activity Community Service Project Activity KEY TERMS AND CONCEPTS sprinkler system fire codes smoke alarm photoelectric

More information

Building Code Clarifications - 7. Fire Resistance

Building Code Clarifications - 7. Fire Resistance Building Code Clarifications - 7. Fire Resistance 7.1 (15-12-030) Use of combustibles in Type III construction roof assemblies Code Section (15-12-030) Use of Combustibles was revised on May 17, 2000,

More information

c. As mandated by law, facilities must obtain and maintain valid zoning permits as well as permits for intended use.

c. As mandated by law, facilities must obtain and maintain valid zoning permits as well as permits for intended use. Walmart Standards for Suppliers Section 7. Health and Safety 7. Health and Safety Suppliers must provide workers with a safe and healthy work environment. Suppliers must take proactive measures to prevent

More information

FIRE SPRINKLER SYSTEM SUPERVISORY SERVICE User s Guide (DamarNet RAR Service)

FIRE SPRINKLER SYSTEM SUPERVISORY SERVICE User s Guide (DamarNet RAR Service) FIRE SPRINKLER SYSTEM SUPERVISORY SERVICE User s Guide (DamarNet RAR Service) The information provided in this user guide pertains to fire suppression sprinkler system monitoring service provided over

More information

Automatic Fire Sprinkler Submittal Requirements

Automatic Fire Sprinkler Submittal Requirements Automatic Fire Sprinkler Submittal Requirements All commercial and industrial buildings with a total floor area of 5000 sq. ft. shall have an approved automatic sprinkler system installed. The Windsor-Severance

More information

FIRE DEPARTMENT CITY OF NEW YORK STUDY MATERIAL FOR THE EXAMINATION FOR THE CERTIFICATE OF FITNESS FOR S-12 CITYWIDE SPRINKLER SYSTEM

FIRE DEPARTMENT CITY OF NEW YORK STUDY MATERIAL FOR THE EXAMINATION FOR THE CERTIFICATE OF FITNESS FOR S-12 CITYWIDE SPRINKLER SYSTEM Rev: 3-27-13 FIRE DEPARTMENT CITY OF NEW YORK STUDY MATERIAL FOR THE EXAMINATION FOR THE CERTIFICATE OF FITNESS FOR S-12 CITYWIDE SPRINKLER SYSTEM Issued 11/29/10 New York City Fire Department - All rights

More information

FDNY C14 Certificate of Fitness Quiz

FDNY C14 Certificate of Fitness Quiz FDNY C14 Certificate of Fitness Quiz Name: Date: 1. Who issues a New York City laboratory permit? a) Department of Environmental Protection (DEP) b) Department of Environmental Conservation (DEC) c) Occupational

More information

FIRE-FIGHTING DESIGN BRIEF REPORT

FIRE-FIGHTING DESIGN BRIEF REPORT P a g e 1 SECTION 04 (Doc.No.A/DBR 001) FIRE-FIGHTING DESIGN BRIEF REPORT P a g e 2 1.0 SCOPE 2.0 STANDARDS AND CODES 3.0 TYPES OF SYSTEM PROPOSED 4.0 FIRE HYDRANT SYSTEM 5.0 AUTOMATIC SPRINKLER SYSTEM

More information

Overview. Components of an alarm system Technology behind the equipment Communication Platforms Industry Terminology False Alarm Tips DSC products

Overview. Components of an alarm system Technology behind the equipment Communication Platforms Industry Terminology False Alarm Tips DSC products Basic Security 101 Overview Components of an alarm system Technology behind the equipment Communication Platforms Industry Terminology False Alarm Tips DSC products Components of an Alarm System Main Control

More information

Dennis Fire Department Fire Prevention Mark Dellner Fire Chief

Dennis Fire Department Fire Prevention Mark Dellner Fire Chief Dennis Fire Department Fire Prevention Mark Dellner Fire Chief FIRE SAFETY INSPECTION GUIDELINES FOR COMMERCIAL PROPERTIES (MA Fire Prevention Regulations 527 CMR, MGL Chapter 148) FIRE PREVENTION CHECKLIST-

More information

Commercial Fire Inspections

Commercial Fire Inspections Commercial Fire Inspections Fire Department Inspection Requests and Procedures The following guidelines shall be used when calling for inspection requests: 1. All inspection requests shall be coordinated

More information

Ontario Association of Fire Chiefs Position Paper Residential Fire Sprinklers

Ontario Association of Fire Chiefs Position Paper Residential Fire Sprinklers Ontario Association of Fire Chiefs Position Paper Residential Fire Sprinklers The Ontario Association of Fire Chiefs (OAFC) supports changes to the Ontario Building Code to require that all new residential

More information

FIRE ALARM SYSTEMS PERMIT APPLICATION, PLAN SUBMITTAL, DESIGN, INSTALLATION AND INSPECTION REQUIREMENTS Effective Date: January, 2011

FIRE ALARM SYSTEMS PERMIT APPLICATION, PLAN SUBMITTAL, DESIGN, INSTALLATION AND INSPECTION REQUIREMENTS Effective Date: January, 2011 Office of the Fire Marshal 1.0 PERMITS FIRE ALARM SYSTEMS PERMIT APPLICATION, PLAN SUBMITTAL, DESIGN, INSTALLATION AND INSPECTION REQUIREMENTS Effective Date: January, 2011 1.1 To acquire an installation

More information

Fire Service Guide to Reducing Unwanted Fire Alarms

Fire Service Guide to Reducing Unwanted Fire Alarms R Copyright 2012 National Fire Protection Association (NFPA). Licensed, by agreement, for individual use and single download on September 11, 2012 to CLACKAMAS FIRE for designated user Clackamas Fire.

More information

General Safety & Health Standards Published by the Division of Building Safety In Cooperation with the Idaho Industrial Commission

General Safety & Health Standards Published by the Division of Building Safety In Cooperation with the Idaho Industrial Commission General Safety & Health Standards Published by the Division of Building Safety In Cooperation with the Idaho Industrial Commission Local Fire Alarm 064. FIRE ALARM SYSTEMS 01. Scope 02. Definitions 03.

More information

DELAWARE STATE FIRE MARSHAL FIRE ALARM SYSTEM CERTIFICATE OF INSTALLATION

DELAWARE STATE FIRE MARSHAL FIRE ALARM SYSTEM CERTIFICATE OF INSTALLATION Phone System Owner Phone System Engineered by: of Record Drawings: of System Manuals: of Test Reports: System Installer 1. GENERAL INFORMATION Phone Delaware License No: Certificate Holder No. System Supplier

More information

SECTION 16721 FIRE ALARM AND DETECTION SYSTEMS

SECTION 16721 FIRE ALARM AND DETECTION SYSTEMS SECTION 16721 FIRE ALARM AND DETECTION SYSTEMS The equipment requirements of this section apply to the IUB Campus. The IUPUI Campus has a preferred vendor agreement for fire alarm systems. Contact Pat

More information

Telluride Fire Protection District Fire Alarm Systems Policy Version 03/2007

Telluride Fire Protection District Fire Alarm Systems Policy Version 03/2007 Telluride Fire Protection District Fire Alarm Systems Policy Version 03/2007 FIRE ALARM SYSTEMS POLICY TELLURIDE FIRE PROTECTION DISTRICT TABLE OF CONTENTS FIRE ALARM PROTECTION POLICY PLAN REVIEW SUBMITTAL

More information

Fire Safety PROCEDURES January 2011

Fire Safety PROCEDURES January 2011 Fire Safety PROCEDURES January 2011 firesafety@uwo.ca Campus Phones EMERGENCY Dial 911 Fire Safety Service is the focal point for the coordinated administration of the University Fire Safety program and

More information

Fire Safety Log Book

Fire Safety Log Book Fire Safety Log Book Company... Address........ Responsible Person. Competent Person. Date Started For Additional Information: Safety Management (UK) Ltd Holme Suite, Clawthorpe Hall Business Centre, Burton

More information

Emergency Evacuation Plan: 232 King St.

Emergency Evacuation Plan: 232 King St. Emergency Evacuation Plan: 232 King St. Effective Date: July 2003 Revisions: 0 Approved on: April 20, 2004 Table of Contents 1.0 Building Resources... 1 2.0 Human Resources... 2 3.0 Definitions... 3 4.0

More information

FIRE ALARM SYSTEM RECORD OF COMPLETION

FIRE ALARM SYSTEM RECORD OF COMPLETION FUNDAMENTALS OF FIRE ALARM SYSTEMS 72 33 FIRE ALARM SYSTEM RECORD OF COMPLETION To be completed by the system installation contractor at the time of system acceptance and approval. 1. PROTECTED PROPERTY

More information

DCSS (ACB) Data Center Fire Suppression Procedures

DCSS (ACB) Data Center Fire Suppression Procedures May 18, 2015 DCSS (ACB) Data Center Fire Suppression Procedures Purpose: This document is intended for all individuals who have access to the data center at 1011 West Springfield Avenue, Advanced Computation

More information

FIRE ALARM SYSTEM RECORD OF COMPLETION

FIRE ALARM SYSTEM RECORD OF COMPLETION FIRE ALARM SYSTEM RECORD OF COMPLETION To be completed by the system installation contractor at the time of system acceptance and approval. 1. Protected Property Information Name of property: Description

More information

ENVIRONMENTAL HEALTH & SAFETY 6 East Dr., Amherst MA 01002-5000

ENVIRONMENTAL HEALTH & SAFETY 6 East Dr., Amherst MA 01002-5000 AMHERST COLLEGE ENVIRONMENTAL HEALTH & SAFETY 6 East Dr., Amherst MA 01002-5000 Michael Zlogar April 11, 2001 Assistant Fire Chief Amherst Fire Department 68 North Pleasant St. Amherst, MA 01004 FIRE ALARM

More information

FIRE ALARM SYSTEM. A. Shop drawings shall be submitted as follows: 1. Manufacturer's published literature. for aspproval.

FIRE ALARM SYSTEM. A. Shop drawings shall be submitted as follows: 1. Manufacturer's published literature. for aspproval. Polk School District Specifications for the New Fire Alarm in the Existing Building Eastside Elementary School FIRE ALARM SYSTEM 1.01 SUBMITTALS A. Shop drawings shall be submitted as follows: 1. Manufacturer's

More information

TYPICAL FIRE SAFETY INSPECTION VIOLATIONS

TYPICAL FIRE SAFETY INSPECTION VIOLATIONS TYPICAL FIRE SAFETY INSPECTION VIOLATIONS The following is a list of typical violations often found by inspectors and a generic solution. You can use this list to improve the safety of your facility, to

More information

SECTION 16721 FIRE ALARM AND DETECTION SYSTEM

SECTION 16721 FIRE ALARM AND DETECTION SYSTEM 1. GENERAL 1.1. Related Documents: 1.2. Scope: 1.1.1. The general provisions of the Contract, including General and Supplementary Conditions and General Requirements apply to the work specified in this

More information

PART II: New Construction Inspections and Acceptance Testing Procedures

PART II: New Construction Inspections and Acceptance Testing Procedures Stafford County Fire Marshal s Office Handbook for Building/Fire Code Policies and Guidelines PART II: New Construction Inspections and Acceptance Testing Procedures Phone: 540-658-8648 Fax: 540-658-9128

More information

Butch Browning State Fire Marshal, Bobby Jindal Governor - Licensing Requirements

Butch Browning State Fire Marshal, Bobby Jindal Governor - Licensing Requirements LOUISIANA DEPARTMENT OF PUBLIC SAFETY AND CORRECTIONS OFFICE OF STATE FIRE MARSHAL, CODE ENFORCEMENT AND BUILDING SAFETY H. Butch Browning State Fire Marshal Bobby Jindal Governor Licensing Law and Rules

More information

Static Electricity. A Health and Safety Guideline for Your Workplace. What Are Some Sources of Static Electricity? What is Static Electricity?

Static Electricity. A Health and Safety Guideline for Your Workplace. What Are Some Sources of Static Electricity? What is Static Electricity? A Health and Safety Guideline for Your Workplace What is static electricity? What causes it? How is it hazardous? And, most importantly, how can it be controlled? All of these questions will be answered

More information

A. Fire Protection Plan. B. Access and Parking

A. Fire Protection Plan. B. Access and Parking Standards for Construction Site Fire Safety For Use by Unidocs Member Agencies or where approved by your Local Jurisdiction Authority Cited: California Fire Code (CFC) These standards are intended to prescribe

More information

GUIDELINE 5. CLASSES OF FIRE, TYPES OF PORTABLE FIRE EXTINGUISHERS, INSPECTION & MAINTENANCE OF FIRE EXTINGUISHERS IN UNIVERSITY BUILDINGS

GUIDELINE 5. CLASSES OF FIRE, TYPES OF PORTABLE FIRE EXTINGUISHERS, INSPECTION & MAINTENANCE OF FIRE EXTINGUISHERS IN UNIVERSITY BUILDINGS GUIDELINE 5. CLASSES OF FIRE, TYPES OF PORTABLE FIRE EXTINGUISHERS, INSPECTION & MAINTENANCE OF FIRE EXTINGUISHERS IN UNIVERSITY BUILDINGS 1.0 PURPOSE 1.1 To provide an overview of fire extinguisher use

More information

Oxford House Evacuation Plan SECTION 1. RESPONSIBILITIES. A. COOP Staff

Oxford House Evacuation Plan SECTION 1. RESPONSIBILITIES. A. COOP Staff Oxford House Evacuation Plan SECTION 1. RESPONSIBILITIES A. COOP Staff 1. COOP DIRECTOR will work with the UHDS Safety & Inspection Coordinator (SIC) to establish an emergency operation plan for the building.

More information

Preventing Overheated Boiler Incidents

Preventing Overheated Boiler Incidents Preventing Overheated Boiler Incidents PSE&G Appliance Service October 2012 Runaway Boiler Explosion Review Items Hazard Background Past Incidents PSE&G Emergency Response Future Process Improvements What

More information

ALVERNIA UNIVERSITY OSHA REGULATION: 29 CFR 1910.252 WELDING, CUTTING, AND BRAZING ( HOT WORK ) SECTION: 3600

ALVERNIA UNIVERSITY OSHA REGULATION: 29 CFR 1910.252 WELDING, CUTTING, AND BRAZING ( HOT WORK ) SECTION: 3600 OSHA REGULATION: 9 CFR 90.5 WELDING, CUTTING, AND BRAZING ( HOT WORK ) A. POLICY. This procedure follows requirements set forth in 9 CFR 90.5.. This policy applies to all Hot Work operations being done

More information