Get the Right GC for Your Industry
|
|
- Austen Craig
- 8 years ago
- Views:
Transcription
1 Get the Right GC for Your Industry Shimadzu was founded on the basis of "Technology for Science" and we continue to take the initiative in the analytical technology industry. From our absorption spectrophotometers to our structure and surface analyzers and chromatographs, our high-quality products are the fruits of our original technologies. As a wholly-owned subsidiary of Shimadzu Corporation, established in 1875, Shimadzu Scientific Instruments, Inc. continues to discover cutting-edge technologies to meet customer needs and requirements that result in the development of future instrumentation targeted at Solutions for Science. At SSI, you, the customer, are our number one priority and we believe that quality is our responsibility. SHIMADZU EUROPE LTD., OPERATION CENTER Albert-Hahn-Strasse 6-10, D Duisburg, F.R. Germany Phone: 49(203) FAX: 49(203) SHIMADZU SCIENTIFIC INSTRUMENTS, INC Riverwood Drive, Columbia, MD 21046, USA Phone: or FAX: SHIMADZU CORPORATION, International Marketing Division 3. Kanda-Nishikicho 1-chome, Chiyoda-ku, Tokyo 101, Japan Phone: 81(3) FAX: 81(3) Cable Add.: SHIMADZU TOKYO Overseas Telex No.: (Answer Code: SHMDT J) SHIMADZU (ASIA PACIFIC) PTE LTD. 16 Science Park Drive #01-01 Singapore Science Park, Singapore , Republic of Singapore Phone: FAX: SHIMADZU SCIENTIFIC INSTRUMENTS (OCEANIA) PTY LTD. Rydalmere Business Park, Unit T, South Street, Rydalmere N.S.W. 2116, Australia Phone: 61(2) FAX: 61(2)
2 Table of Contents Hydrocarbon Processing Analyzers GC-14A LPG Analyzer... 9 Specialty Gas Analyzers GC - 8AIT Natural Gas Analyzer # GC-2010 Simulated Distillation Analyzer... 9 GC-14A Nitrous Oxide Analyzer GC - 8AIT Natural Gas Analyzer # GC-17A Simulated Distillation Analyzer... 9 GC-8A Nitrous Oxide Analyzer Shimadzu began building Gas Chromatography products in 1955 and remains committed to building the best GC products in the world. Throughout our long history, the customer's needs have always been central to all our design, manufacturing, and testing processes. As part of this continuing commitment, we developed the System GC program, which provides our customers with the best applicated and fully configured GC products available anywhere. Configured and tested in Shimadzu's System Integration Technology Lab, the system is shipped with proof of performance, QA/QC and a field test standard. Upholding the Shimadzu tradition, the System GC group is uncompromising in the quest for excellence and in optimizing separations and making the products easy to use. Expect performance, quality and value with System GC! GC-14A Natural Gas Analyzer # GC-2010 Natural Gas Analyzer by GPA Standard... 2 GC-17A Natural Gas Analyzer by GPA Standard... 2 GC-14A Natural Gas Analyzer by GPA Standard... 2 GC-2010 Natural Gas Analyzer by GPA Standard with Fixed Gas Separation... 3 GC-14A Natural Gas Analyzer by GPA Standard with Fixed Gas Separation... 3 GC-2010 Natural Gas Analyzer by ASTM D GC-17A Natural Gas Analyzer by ASTM D GC-14A Natural Gas Analyzer by ASTM D GC-2010 Extended Natural Gas Analyzer... 4 GC-17A Extended Natural Gas Analyzer... 5 GC-14A Extended Natural Gas Analyzer... 5 GC-2010 Natural Gas and Gaseous Fuels Sulfur Analyzer by ASTM D GC-17A Natural Gas and Gaseous Fuels Sulfur Analyzer by ASTM D GC-14A Natural Gas and Gaseous Fuels Sulfur Analyzer by ASTM D GC-2010 Light Petroleum Sulfur Analyzer by ASTM D GC-2010 PIANO Analyzer... 9 GC-17A PIANO Analyzer GC-2010 DHA Analyzer GC-17A DHA Analyzer GC-2010 Oxygenates in Gasoline by ASTM D GC-17A Oxygenates in Gasoline by ASTM D GC-14A Oxygenates in Gasoline by ASTM D GC-2010 Refinery Gas by UOP GC-2010 Fast Refinery Gas GC-2010 ASTM D 2504 Analyzer GC-17A ASTM D 2504 Analyzer GC-14A ASTM D 2504 Analyzer GC-2010 ASTM D 2505 Analyzer GC-17A ASTM D 2505 Analyzer GC-14A ASTM D 2505 Analyzer GC-2010 ASTM D 3606 Analyzer GC-17A ASTM D 3606 Analyzer GC-14A ASTM D 3606 Analyzer GC-2010 Sulfur and Fixed Gas Analyzer GC-8A Chlorine Gas Analyzer 1 by ASTM D GC-8A Chlorine Gas Analyzer 2 by ASTM D GC-17A Specialty Gas Analyzer GC-17A Specialty Gas Analyzer GC-17A H2 Contaminants Analyzer...17 GC-14A H2 Contaminants Analyzer...17 GC-8A H2 Contaminants Analyzer...17 GC-17A N2 Contaminants Analyzer GC-14A N2 Contaminants Analyzer GC-8A N2 Contaminants Analyzer...17 Environmental and Safety GC-17A TOGAS...18 GC-14A TOGAS...18 GC-14A Greenhouse Gas Analyzer...18 GC-17A Mine Gas Analyzer GC-14A Mine Gas Analyzer GC-14A Mud Logging, Well Gas Sampling Analyzer GC-14A Fuel Cell Analyzer GC-17A Light Petroleum Sulfur Analyzer by ASTM D GC-17A Sulfur and Fixed Gas Analyzer GC-2010 Methane in Exhaust Analyzer by SAE J Order your System GC today! Call or log-on to for more information. GC-14A Light Petroleum Sulfur Analyzer by ASTM D GC-2010 Natural Gas and Gaseous Fuels Sulfur Analyzer by ASTM D GC-17A Natural Gas and Gaseous Fuels Sulfur Analyzer by ASTM D GC-14A Natural Gas and Gaseous Fuels Sulfur Analyzer by ASTM D GC-17A LPG Analyzer by GPA Standard... 8 GC-14A Sulfur and Fixed Gas Analyzer GCMS QP-2010 Aromatics in Gasoline by ASTM D GCMS QP-5000 Aromatics in Gasoline by ASTM D GC-2010 Aromatics in Finished Gasoline by ASTM D GC-14A Aromatics in Finished Gasoline by ASTM D GC-17A Methane in Exhaust Analyzer by SAE J GC-14A Methane in Exhaust Analyzer by SAE J
3 Hydrocarbon Processing Analyzers GC - 8AIT Natural Gas Analyzer #1 Method: ASTM 1945 & 3588 Part Number: Analytes: C6+, C1-C5, O2, N2, CO2 Columns: 6 packed This system is fully configured with a CR8A data processor prepared for operation at the factory. Each system is a turnkey analyzer for performing natural gas assays of the components listed with Compressibility, BTU and Specific Gravity calculations provided for the appropriate compounds. Analysis time approximately 18 minutes. In most cases, He and H2 are either not present or present in such small quantities that these need not be determined. GC - 8AIT Natural Gas Analyzer #2 Method: GPA 2261 Part Number: Analytes: C6+, N2/air, CH4, CO2, C2, H2S, C3-C5 Columns: 4 packed This system is fully configured with a CR8A data processor prepared for operation at the factory. Each system is a turnkey analyzer for performing natural gas assays of the components listed with Compressibility, BTU and Specific Gravity calculations provided for the appropriate compounds. Analysis time approximately 18 minutes. In most cases, He and H2 are either not present or present in such small quantities that these need not be determined. GC-14A Natural Gas Analyzer #3 Method: ASTM 1945 Part Number: Analytes: C6+, C3-C5, CO2, C2, O2, N2, CH4 /TCD Columns: 7 packed 4 valves This turnkey system for natural gas incorporates a C6+ backflush and analyzes C3-C5 on the FID in that order. The valve timing then allows for CO2, C2, O2, N2 and CH4 to be detected on the TCD respectfully. Must include a data station or data processor. Compressibility, BTU and Specific Gravity calculations can be provided for the appropriate compounds. Analysis time approximately 60 minutes. In most cases, He and H2 are either not present or present in such small quantities that these need not be determined. GC-2010 Natural Gas Analyzer by GPA Standard Method: GPA 2261 Part Number: Analytes: C6+, N2/air, CH4, CO2, C2, H2S, C3-C5 This turnkey system is constructed according to The Gas Processors Association. C6+ components are grouped into a single peak using a pre-cut column, which is backflushed to elute the hexanes and heavier as the first peak. Nitrogen/air, methane, carbon dioxide and ethane through n-pentane elute on forward flow of carrier gas through the partition column. Analysis time is approximately 18 minutes. In most cases, He and H2 are either not present or present in such small quantities that these need not be determined. GC-17A Natural Gas Analyzer by GPA Standard Method: GPA 2261 Part Number: Analytes: C6+, N2/air, CH4, CO2, C2, H2S, C3-C5 This turnkey system is constructed according to The Gas Processors Association. C6+ components are grouped into a single peak using a pre-cut column, which is backflushed to elute the hexanes and heavier as the first peak. Nitrogen/air, methane, carbon dioxide and ethane through n-pentane elute on forward flow of carrier gas through the partition column. Analysis time is approximately 18 minutes. In most cases, He and H2 are either not present or present in such small quantities that these need not be determined. GC-14A Natural Gas Analyzer by GPA Standard Method: GPA 2261 Part Number: Analytes: C6+, N2/air, CH4, CO2, C2, H2S, C3-C5 This turnkey system is constructed according to The Gas Processors Association. C6+ components are grouped into a single peak using a pre-cut column, which is backflushed to elute the hexanes and heavier as the first peak. Nitrogen/air, methane, carbon dioxide and ethane through n-pentane elute on forward flow of carrier gas through the partition column. Analysis time is approximately 18 minutes. In most cases, He and H2 are either not present or present in such small quantities that these need not be determined. GC-2010 Natural Gas Analyzer by GPA Standard with Fixed Gas Separation Method: GPA 2261 Part Number: Analytes: TCD1 - C6+, N2/air, CH4, CO2, C2, H2S, C3-C5 TCD2 - H2, O2, N2, CH4, CO Detectors: 2 TCD s Columns: 5 packed This turnkey system is constructed according to The Gas Processors Association. C6+ components are grouped into a single peak using a pre-cut column, which is backflushed to elute the hexanes and heavier as the first peak. Nitrogen/air, methane, carbon dioxide and ethane through n-pentane elute on forward flow of carrier gas through the partition column, which is detected by the first TCD The second gas sampling valve directs the natural gas sample to a molecular sieve 13X for separation of H2, O2, N2, CH4, CO which is detected by the second TCD Analysis time is approximately 18 minutes. In most cases, He and H2 are either not present or present in such small quantities that these need not be determined. Natural Gas Analyzers by GPA Standard with Fixed Gas Separation GC-14A Natural Gas Analyzer by GPA Standard with Fixed Gas Separation Method: GPA 2261 Part Number: Analytes: TCD sample side - C6+, N2/air, CH4, CO2, C2, H2S, C3-C5 TCD reference - H2, O2, N2, CH4, CO using sample and reference Columns: 5 packed This turnkey system is constructed according to The Gas Processors Association. C6+ components are grouped into a single peak using a pre-cut column, which is backflushed to elute the hexanes and heavier as the first peak. Nitrogen/air, methane, carbon dioxide and ethane through n-pentane elute on forward flow of carrier gas through the partition column, which is detected by the sample side of the TCD-14A. The second gas sampling valve directs the natural gas sample to a molecular sieve 13X for separation of H2, O2, N2, CH4, CO which is detected by the reference side of the TCD- 14A. Analysis time is approximately 18 minutes. In most cases, He and H2 are either not present or present in such small quantities that these need not be determined. Must include a data processor or data station
4 GC-2010 Natural Gas Analyzer by ASTM D 1945 Method: ASTM 1945 Part Number: Analytes: C6+, C3-C5, CO2, C2, O2, N2, CH4 Columns: 4 packed The three-valve GC system is widely used for the routine analysis of natural gas. Basically the same as method GPA 2261, this turnkey analyzer groups C6+ components into a single peak using a precut column, which is backflushed to elute the hexanes and heavier as the first peak. The valve timing then allows for C3-C5, carbon dioxide, ethane, oxygen, nitrogen, and methane to elute to the TCD-2010 in that order. The final analysis time is approximately minutes. In most cases, He and H2 are either not present or present in such small quantities that these need not be determined. GC-17A Natural Gas Analyzer by ASTM D 1945 Method: ASTM 1945 Part Number: Analytes: C6+, C3-C5, CO2, C2, O2, N2, CH4 Columns: 4 packed The three-valve GC system is widely used for the routine analysis of natural gas. Basically the same as method GPA 2261, this turnkey analyzer groups C6+ components into a single peak using a precut column, which is backflushed to elute the hexanes and heavier as the first peak. The valve timing then allows for C3-C5, carbon dioxide, ethane, oxygen, nitrogen, and methane to elute to the TCD-17A in that order. The final analysis time is approximately minutes. In most cases, He and H2 are either not present or present in such small quantities that these need not be determined. GC-14A Natural Gas Analyzer by ASTM D 1945 Method: ASTM 1945 Part Number: Analytes: C6+, C3-C5, CO2, C2, O2, N2, CH4 Columns: 4 packed The three-valve GC system is widely used for the routine analysis of natural gas. Basically the same as method GPA 2261, this turnkey analyzer groups C6+ components into a single peak using a precut column, which is backflushed to elute the hexanes and heavier as the first peak. The valve timing then allows for C3-C5, carbon dioxide, ethane, oxygen, nitrogen, and methane to elute to the TCD-14A in that order. The final analysis time is approximately minutes. In most cases, He and H2 are either not present or present in such small quantities that these need not be determined. GC-2010 Extended Natural Gas Analyzer Part Number: Analytes: separate all components /FID, 1 capillary A detailed compositional analysis is often required to provide a better evaluation of the oil and natural gas field. The 2-valve Natural Gas Extended Analysis System traps O2, N2, CH4, CO onto a molecular sieve column and allows the separation of CO2, H2S, and C2 on a porous polymer column for detection to a TCD The 10-port sampling valve is set back to the load position which allows the other hydrocarbons to be loaded on an SPL-2010 injector in the split mode. The hydrocarbons are separated by a PIANO capillary column for detection by an FID Analysis time varies depending on the particular specifications set by the operator. In most cases, He and H2 are either not present or present in such small quantities that these need not be determined. Must include GC-2010 with AOC20i Autoinjector and AOC20s 150 Sample Carousel GC-17A Extended Natural Gas Analyzer Part Number: Analytes: separate all components /FID, 1 capillary A detailed compositional analysis is often required to provide a better evaluation of the oil and natural gas field. The 2-valve Natural Gas Extended Analysis System traps O2, N2, CH4, CO onto a molecular sieve column and allows the separation of CO2, H2S, and C2 on a porous polymer column for detection to a TCD-17A. The 10-port sampling valve is set back to the load position which allows the other hydrocarbons to be loaded on an SPL-17A injector in the split mode. The hydrocarbons are separated by a PIANO capillary column for detection by an FID-17A. Analysis time varies depending on the particular specifications set by the operator. In most cases, He and H2 are either not present or present in such small quantities that these need not be determined. Must include GC-14A Extended Natural Gas Analyzer Part Number: Analytes: separate all components /FID, 1 capillary A detailed compositional analysis is often required to provide a better evaluation of the oil and natural gas field. The 2-valve Natural Gas Extended Analysis System traps O2, N2, CH4, CO onto a molecular sieve column and allows the separation of CO2, H2S, and C2 on a porous polymer column for detection to a TCD-14A. The 10-port sampling valve is set back to the load position which allows the other hydrocarbons to be loaded on an SPL-14A injector in the split mode. The hydrocarbons are separated by a PIANO capillary column for detection by an FID-14A. Analysis time varies depending on the particular specifications set by the operator. In most cases, He and H2 are either not present or present in such small quantities that these need not be determined. Must include GC-2010 Natural Gas and Gaseous Fuels Sulfur Analyzer by ASTM D 5504 Method: ASTM 5504 Part Number: Detectors: SCD/FID Columns: 2 capillary This turnkey system is designed for the determination of individual volatile sulfur-containing compounds in gaseous fuels including natural gas. It consists of a 10-port sampling valve with 2 sample loops, a SPL-2010 and 2 capillary columns that are in parallel. The sulfur compounds are detected by a sulfur chemiluminescence detector and a FID The detection range is 0.01 to 1000mg/m3 based upon the analysis of a 1-cm3 sample. Must GC-17A Natural Gas and Gaseous Fuels Sulfur Analyzer by ASTM D 5504 Method: ASTM 5504 Part Number: Detectors: SCD/FID Columns: 2 capillary This turnkey system is designed for the determination of individual volatile sulfur-containing compounds in gaseous fuels including natural gas. It consists of a 10-port sampling valve with 2 sample loops, an SPL-17A and 2 capillary columns that are in parallel. The sulfur compounds are detected by a sulfur chemiluminescence detector and an FID-17A. The detection range is 0.01 to 1000mg/m3 based upon the analysis of a 1-cm3 sample. Must GC-14A Natural Gas and Gaseous Fuels Sulfur Analyzer by ASTM D 5504 Method: ASTM 5504 Part Number: Detectors: SCD/FID Columns: 2 capillary This turnkey system is designed for the determination of individual volatile sulfur-containing compounds in gaseous fuels including natural gas. It consists of a 10-port sampling valve with 2 sample loops, an SPL-14A and 2 capillary columns that are in parallel. The sulfur compounds are detected by a sulfur chemiluminescence detector and an FID-14A. The detection range is 0.01 to 1000mg/m3 based upon the analysis of a 1-cm3 sample. Must 4 5
5 GC-2010 Light Petroleum Sulfur Analyzer by ASTM D 5623 Method: ASTM 5623 Part Number: Detectors: SCD This turnkey system covers the determination of volatile sulfur-containing compounds in light petroleum liquids. The system is applicable to distillates, gasoline motor fuels (including those containing oxygenates) and other petroleum liquids with a final boiling point of approximately 230 C. Detection of sulfur compounds is accomplished using a sulfur chemiluminescence detector. The applicable concentration range of individual sulfur species is 0.1 to 100mg/kg. GC-17A Light Petroleum Sulfur Analyzer by ASTM D 5623 Method: ASTM 5623 Part Number: Detectors: SCD This turnkey system covers the determination of volatile sulfur-containing compounds in light petroleum liquids. The system is applicable to distillates, gasoline motor fuels (including those containing oxygenates) and other petroleum liquids with a final boiling point of approximately 230 C. Detection of sulfur compounds is accomplished using a sulfur chemiluminescence detector. The applicable concentration range of individual sulfur species is 0.1 to 100mg/kg. GC-14A Light Petroleum Sulfur Analyzer by ASTM D 5623 Method: ASTM 5623 Part Number: Detectors: SCD This turnkey system covers the determination of volatile sulfur-containing compounds in light petroleum liquids. The system is applicable to distillates, gasoline motor fuels (including those containing oxygenates) and other petroleum liquids with a final boiling point of approximately 230 C. Detection of sulfur compounds is accomplished using a sulfur chemiluminescence detector. The applicable concentration range of individual sulfur species is 0.1 to 100mg/kg. GC-2010 Natural Gas and Gaseous Fuels Sulfur Analyzer by ASTM D 6228 Method: ASTM 6228 Part Number: Detectors: FPD This turnkey system provides for the determination of individual volatile sulfur-containing compounds in gaseous fuels using the FPD-2010 Flame Photometric Detector. The detection range for sulfur compounds is from 0.02 to 20 mg/m3 of sulfur based upon the analysis of a 1ml sample using a gas sampling valve. Must GC-17A LPG Analyzer by GPA Standard GC-17A Light Petroleum Sulfur Analyzer by ASTM D
6 GC-17A Natural Gas and Gaseous Fuels Sulfur Analyzer by ASTM D 6228 Method: ASTM 6228 Part Number: Detectors: FPD This turnkey system provides for the determination of individual volatile sulfur-containing compounds in gaseous fuels using the FPD-17 Flame Photometric Detector. The detection range for sulfur compounds is from 0.02 to 20 mg/m3 of sulfur based upon the analysis of a 1ml sample using a gas sampling valve. Must include GC-14A Natural Gas and Gaseous Fuels Sulfur Analyzer by ASTM D 6228 Method: ASTM 6228 Part Number: Detectors: FPD This turnkey system provides for the determination of individual volatile sulfur-containing compounds in gaseous fuels using the FPD-14 Flame Photometric Detector. The detection range for sulfur compounds is from 0.02 to 20 mg/m3 of sulfur based upon the analysis of a 1ml sample using a gas sampling valve. Must GC-17A LPG Analyzer by GPA Standard Method: GPA 2177 Part Number: Analytes: C6+, N2/air, CH4, CO2, C2, H2S, C3-C5 This turnkey system is constructed according to The Gas Processors Association. C6+ components are grouped into a single peak using a pre-cut column, which is backflushed to elute the hexanes and heavier as the first peak. Nitrogen/air, methane, carbon dioxide and ethane through n-pentane elute on forward flow of carrier gas through the partition column. In addition, the system calculates the liquid volume %, specific gravity, and vapor pressure. Analysis time is approximately 18 minutes. In most cases, He and H2 are either not present or present in such small quantities that these need not be determined. Must include a data processor or data station. GC-14A LPG Analyzer Part Number: Analytes: C6+, C3-C5 The GC-14A Liquid Petroleum Gas System is a turnkey analyzer that quantitates saturated and unsaturated C3-C5 hydrocarbons, and C6+ backflushed as one initial peak. In addition, the system calculates the liquid volume %, specific gravity, and vapor pressure. Analysis time is approximately 35 minutes. In most cases, He and H2 are either not present or present in such small quantities that these need not be determined. Must include a data processor or data station. GC-2010 Simulated Distillation Analyzer Method: ASTM 2887, 3710, 5307, 6352 Part Number: This turnkey analyzer comes with the appropriate hardware and software to perform any of the simulated distillation ASTM methods, which are ASTM D 2887, ASTM D3710, ASTM D 5307, ASTM D 6352, and ASTM D Includes enhanced data station, GC Solution Software, and Petro Software. GC-17A Simulated Distillation Analyzer Method: ASTM 2887, 3710, 5307, 6352 Part Number: This turnkey analyzer comes with the appropriate hardware and software to perform any of the simulated distillation ASTM methods, which are ASTM D 2887, ASTM D3710, ASTM D 5307, ASTM D 6352, and ASTM D Includes enhanced data station, GC Solution Software, and Petro Software. GC-2010 PIANO Analyzer Part Number: The PIANO Analyzer is a single-column method that involves analyzing the naphtha sample for paraffins, olefins, naphthalenes, and aromatics. This system comes with the appropriate hardware and software to perform PIANO analysis. Includes enhanced data station, GC Solution Software, and Petro Software. GC-2010 PIANO Analyzer GC-2010 Simulated Distillation Analyzer 8 9
7 GC-17A PIANO Analyzer Part Number: The PIANO Analyzer is a single-column method that involves analyzing the naphtha sample for paraffins, olefins, naphthalenes, and aromatics. This system comes with the appropriate hardware and software to perform PIANO analysis. Includes enhanced data station, GC Solution Software, and Petro Software. GC-2010 DHA Analyzer Method: ASTM 5134 Part Number: Analytes: Detailed Hydrocarbon The Detailed Hydrocarbon Analysis System covers the determination of hydrocarbon components of petroleum naphthas by ASTM D This system comes with the appropriate hardware and software to perform DHA analysis. Includes enhanced data station, GC Solution Software, and Petro Software. GC-17A DHA Analyzer Method: ASTM 5134 Part Number: Analytes: Detailed Hydrocarbon The Detailed Hydrocarbon Analysis System covers the determination of hydrocarbon components of petroleum naphthas by ASTM D This system comes with the appropriate hardware and software to perform DHA analysis. Includes enhanced data station, GC Solution Software, and Petro Software. GC-2010 Oxygenates in Gasoline by ASTM D 4815 Method: ASTM 4815 Part Number: Analytes: 15 Oxygenated Compounds Columns: 1 packed, 1 capillary This turnkey system quantitates oxygenates in gasoline based on ASTM D Individual ethers are determined from 0.1 to 20.0 as %. Individual alcohols are determined from 0.1 to 12.0 mass %. Analysis time is approximately 15 minutes. Must include a data GC-17A Oxygenates in Gasoline by ASTM D 4815 Method: ASTM 4815 Part Number: Analytes: 15 Oxygenated Compounds Columns: 1 packed, 1 capillary This turnkey system quantitates oxygenates in gasoline based on ASTM D Individual ethers are determined from 0.1 to 20.0 as %. Individual alcohols are determined from 0.1 to 12.0 mass %. Analysis time is approximately 15 minutes. Must include a data GC-14A Oxygenates in Gasoline by ASTM D 4815 Method: ASTM 4815 Part Number: Analytes: 15 Oxygenated Compounds Columns: 1 packed, 1 capillary This turnkey system quantitates oxygenates in gasoline based on ASTM D Individual ethers are determined from 0.1 to 20.0 as %. Individual alcohols are determined from 0.1 to 12.0 mass %. Analysis time is approximately 15 minutes. Must include a data GC-2010 Refinery Gas by UOP 539 Method: UOP 539 Part Number: Analytes: H2, O2, N2, CO, CO2, C1-C4 hydrocarbons, C5 paraffins individually, and C5 olefins and C6+ hydrocarbons as a composite Detectors: 2 TCD s Columns: 5 packed 4 valves This automated analyzer determines the composite of gas samples, obtained from refining processes or natural sources. Noncondensable gases, methane through C4 hydrocarbons and C5 paraffins are reported individually, while C5 olefins and C6+ hydrocarbons are reported as a composite. H2S, if present, is not determined. Oxygen is not separated from argon. Usually argon is not present in refinery gas. Lower limit of detection is approximately 0.05mol%. Analysis time is approximately 45 minutes. Must include GC-2010 DHA Analyzer GC-2010 Oxygenates in Gasoline by ASTM D
8 GC-2010 Fast Refinery Gas Part Number: Analytes: H2, CO, CO2, O2, N2, H2S, C1-C5, C6+ /FID Columns: 6 packed 5 valves This turnkey system is a dedicated analyzer for the analysis of refinery gases. These gases include H2, O2, N2, CO, CO2, H2S, C1- C5, and C6+ hydrocarbons reported as a composite. This system is configured with six packed columns, three sample loops, five valves, and FID/TCD. Analysis time is approximately 20 minutes. GC-2010 ASTM D 2504 Analyzer Method: ASTM 2504 Part Number: Analytes: H2, O2, N2, CO in non-condensable gases in C2 and lighter hydrocarbons /FID/Methanizer This turnkey system is dedicated for the analysis of non-condensable gases in C2 and lighter hydrocarbon products. H2, O2, N2, and CO are determined at the part per million volume level. Must GC-17A ASTM D 2504 Analyzer Method: ASTM 2504 Part Number: Analytes: H2, O2, N2, CO in non-condensable gases in C2 and lighter hydrocarbons /FID/Methanizer This turnkey system is dedicated for the analysis of non-condensable gases in C2 and lighter hydrocarbon products. H2, O2, N2, and CO are determined at the part per million volume level. Must GC-14A ASTM D 2504 Analyzer Method: ASTM 2504 Part Number: Analytes: H2, O2, N2, CO in non-condensable gases in C2 and lighter hydrocarbons /FID/Methanizer This turnkey system is dedicated for the analysis of non-condensable gases in C2 and lighter hydrocarbon products. H2, O2, N2, and CO are determined at the part per million volume level. Must GC-2010 ASTM D 2505 Analyzer Method: ASTM 2505 Part Number: Analytes: CO2, CH4, ethane, acetylene and other hydrocarbons /FID/Methanizer This turnkey system is dedicated for the analysis of other hydrocarbons and CO2 in high purity ethylene. CO2, CH4, ethane, acetylene and other hydrocarbons are determined at the 1 to 500 part per million volume level. GC-17A ASTM D 2505 Analyzer Method: ASTM 2505 Part Number: Analytes: CO2, CH4, ethane, acetylene and other hydrocarbons /FID/Methanizer This turnkey system is dedicated for the analysis of other hydrocarbons and CO2 in high purity ethylene. CO2, CH4, ethane, acetylene and other hydrocarbons are determined at the 1 to 500 part per million volume level. GC-14A ASTM D 2505 Analyzer Method: ASTM 2505 Part Number: Analytes: CO2, CH4, ethane, acetylene and other hydrocarbons /FID/Methanizer This turnkey system is dedicated for the analysis of other hydrocarbons and CO2 in high purity ethylene. CO2, CH4, ethane, acetylene and other hydrocarbons are determined at the 1 to 500 part per million volume level. Must include a data processor or data station. GC-2010 ASTM D 3606 Analyzer Method: ASTM 3606 Part Number: Analytes: Benzene, Toluene in Finished Gasoline This automated analyzer is dedicated to the separation and quantitation of benzene and toluene in finished gasoline. Benzene can be determined between the levels of 0.1 and 5 volume % and toluene can be determined between the levels of 2 and 20 volume %. Analysis time is approximately 10 minutes. Must include a data GC-17A ASTM D 3606 Analyzer Method: ASTM 3606 Part Number: Analytes: Benzene, Toluene in Finished Gasoline This automated analyzer is dedicated to the separation and quantitation of benzene and toluene in finished gasoline. Benzene can be determined between the levels of 0.1 and 5 volume % and toluene can be determined between the levels of 2 and 20 volume %. Analysis time is approximately 10 minutes. Must include a data GC-14A ASTM D 3606 Analyzer Method: ASTM 3606 Part Number: Analytes: Benzene, Toluene in Finished Gasoline This automated analyzer is dedicated to the separation and quantitation of benzene and toluene in finished gasoline. Benzene can be determined between the levels of 0.1 and 5 volume % and toluene can be determined between the levels of 2 and 20 volume %. Analysis time is approximately 10 minutes. Must include a data GC-2010 Sulfur and Fixed Gas Analyzer Part Number: Analytes: O2, N2, CO, CO2, COS, SO2 This unit separates and quantifies CO2, COS, SO2, N2, O2, and CO. Also, Cl2 and TiCl4 can be quantified. Detection limit is at the 0.01 % range. Analysis time is approximately 30 minutes. Must GC-17A Sulfur and Fixed Gas Analyzer Part Number: Analytes: O2, N2, CO, CO2, COS, SO2 This unit separates and quantifies CO2, COS, SO2, N2, O2, and CO. Also, Cl2 and TiCl4 can be quantified. Detection limit is at the 0.01 % range. Analysis time is approximately 30 minutes. Must GC-14A Sulfur and Fixed Gas Analyzer Part Number: Analytes: O2, N2, CO, CO2, COS, SO2 This unit separates and quantifies CO2, COS, SO2, N2, O2, and CO. Also, Cl2 and TiCl4 can be quantified. Detection limit is at the 0.01 % range. Analysis time is approximately 30 minutes. Must GCMS QP-2010 Aromatics in Gasoline by ASTM D 5769 Method: ASTM 5769 Part Number: Analytes: 24 Aromatics Detectors: MS This GCMS system is used to make the determination of total aromatics in finished gasoline, including reformulated gasoline (RFG) containing oxygenated blending components. This method is used to identify and quantitate concentration, in liquid volume percent, for the following aromatics: benzene, 0.1 to 3%; toluene, 1 to 15%; and total (C6-C12) aromatics, 10 to 40%. ASTM Method D-5769 specifies the calibration of 24 aromatic components using 4 internal standards. A macro program calculates the uncalibrated aromatic C10-C12 compounds and reports all concentrations of compounds of interest in volume percent
9 GCMS QP-5000 Aromatics in Gasoline by ASTM D 5769 Method: ASTM 5769 Part Number: Analytes: 24 Aromatics Detectors: MS This GCMS system is used to make the determination of total aromatics in finished gasoline, including reformulated gasoline (RFG) containing oxygenated blending components. This method is used to identify and quantitate concentration, in liquid volume percent, for the following aromatics: benzene, 0.1 to 3%; toluene, 1 to 15%; and total (C6-C12) aromatics, 10 to 40%. ASTM Method D-5769 specifies the calibration of 24 aromatic components using 4 internal standards. A macro program calculates the uncalibrated aromatic C10-C12 compounds and reports all concentrations of compounds of interest in volume percent. GC-2010 Aromatics in Finished Gasoline by ASTM D 4420 Method: ASTM 4420 Part Number: Analytes: Aromatics to C8, C9+ Detectors: 2 TCDs This turnkey system utilizes two columns and two TCDs. A sample is injected into a polar liquid phase column. The nonaromatics are directed to TCD #2. The column is backflushed immediately before the elution of benzene, and the aromatic portion is directed into the nonpolar liquid phase column. The aromatic components elute according to their boiling points and are detected on TCD #1. Immediately after the C8 aromatics have eluted, the flow through the nonpolar column is reversed to backflush the C9 and heavier aromatics from the column through the detector. GC-14A Aromatics in Finished Gasoline by ASTM D 4420 Method: ASTM 4420 Part Number: Analytes: Aromatics to C8, C9+ This turnkey system utilizes two columns and a dual filament TCD. A sample is injected into a polar liquid phase column. The nonaromatics are directed to the reference side of the TCD and vented to atmosphere. The column is backflushed immediately before the elution of benzene, and the aromatic portion is directed into the nonpolar liquid phase column. The aromatic components elute according to their boiling points and are detected on the analytical side of the TCD. Immediately after the C8 aromatics have eluted, the flow through the nonpolar column is reversed to backflush the C9 and heavier aromatics from the column through the detector. Specialty Gas Analyzers GC-14A Nitrous Oxide Analyzer Part Number: Analytes: N2O Detectors: ECD Columns: 7 packed This analyzer is used for the rapid precise analysis for gases containing nitrous oxide. The combination of a pre-column backflush system with an ECD eliminates interference from water and fluorocarbons, and provides direct analysis for N2O in small sample volumes of ambient air. The system is completely turnkey and automated, having been calibrated and tuned prior to shipment. Analysis time is approximately 5 minutes. Must include a data GC-8A Nitrous Oxide Analyzer Part Number: Analytes: N2O Detectors: ECD Columns: 7 packed This analyzer is used for the rapid precise analysis for gases containing nitrous oxide. The combination of a pre-column backflush system with an ECD eliminates interference from water and fluorocarbons, and provides direct analysis for N2O in small sample volumes of ambient air. The system is completely turnkey and automated, having been calibrated and tuned prior to shipment. Analysis time is approximately 5 minutes. Must include a data GC-8A Chlorine Gas Analyzer 1 by ASTM D 1746 Method: ASTM 1746 Part Number: Analytes: H2, O2, N2, CH4, CO, CO2 Columns: 9 packed This turnkey system is for the analysis of H2, O2, N2, CH4, CO, and CO2 impurities in chlorine gas. Chlorine concentration is not determined. Components heavier than CO2 are backflushed to vent. Range of concentrations determined from 0.1 to 5%. This system is described in ASTM D Analysis time is approximately 10 minutes. GC-8A Chlorine Gas Analyzer 2 by ASTM D 1746 Method: ASTM 1746 Part Number: Analytes: H2, O2, N2, CH4, CO, CO2 Columns: 9 packed This turnkey system is for the analysis of H2, O2, N2, CH4, CO, and CO2 impurities in chlorine gas. Chlorine concentration is not determined. Components heavier than CO2 are backflushed to vent. Range of concentrations determined from 0.1 to 5%. This system is described in ASTM D Analysis time is approximately 10 minutes. GCMS QP 2010 Aromatics in Gasoline GC-14A N2 Nitrous Oxide Analyzer
10 GC-17A Specialty Gas Analyzer 1 Part Number: Analytes: H2, O2, N2, CH4, CO, CO2, SF6, CF4, SiF4 Detectors: PDD The use of Ultra High Purity (UHP) specialty gases demands stringent product purity specifications particularly for the semi-conductor industry. The purity level is <500ppb for CO2, CO, HF, SF6, CF4, Sif4, N2, and O2/AR. A confidence level of 50ppb has been determined in daily practical analyses. A GC-17A with a Valco Pulse Discharge Detector (GC-PDD) is used to achieve the required detection levels. All these impurities have a relatively higher vapor pressure than the specialty gases. The pre-column delays the specialty gas and the system is tuned to backflush the matrix to waste. This system incorporates a column switching valve that allows the sample to be separated and analyzed by one of two columns at a time. Analysis time is approximately 10 minutes per column selection. GC-17A Specialty Gas Analyzer 2 Part Number: Analytes: H2, O2, N2, CH4, CO, CO2, Light Hydrocarbons Detectors: PDD The use of Ultra High Purity (UHP) specialty gases demands stringent product purity specifications particularly for the semi-conductor industry. The purity level is <500ppb for H2, O2, N2, CH4, CO, CO2 and light hydrocarbons. A GC-17A with a Valco Pulse Discharge Detector (GC-PDD) is used to achieve the required detection levels. This turnkey system has a pre-column that delays the specialty gas and the system is tuned to backflush the matrix to waste. The system is designed to pre-cut the fixed gases. However, H2 is allowed to pass to the detector. The analysis order is H2, CO2, light hydrocarbons, O2, N2, CH4, and CO. Analysis time is approximately 20 minutes. Must include a data processor or data station. GC-17A H2 Contaminants Analyzer Part Number: Analytes: Ar, N2, CH4, CO, CO2 This turnkey analyzer is dedicated to the separation and quantitation of impurities in hydrogen. This system consists of a two-stream selection in which Ar, N2, CH4, CO, and CO2 are analyzed by a TCD-17A. Analysis time is approximately 25 minutes. Must include GC-14A H2 Contaminants Analyzer Part Number: Analytes: Ar, N2, CH4, CO, CO2 This turnkey analyzer is dedicated to the separation and quantitation of impurities in hydrogen. This system consists of a two-stream selection in which Ar, N2, CH4, CO, and CO2 are analyzed by a TCD-14A. Analysis time is approximately 25 minutes. Must include GC-17A Specialty Gas Analyzer GC-8A H2 Contaminants Analyzer Part Number: Analytes: Ar, N2, CH4, CO, CO2 This turnkey analyzer is dedicated to the separation and quantitation of impurities in hydrogen. This system consists of a two-stream selection in which Ar, N2, CH4, CO, and CO2 are analyzed by a TCD-8A. Analysis time is approximately 25 minutes. Must include GC-17A N2 Contaminants Analyzer Part Number: Analytes: H2, O2 Columns: 1 packed This turnkey analyzer is dedicated to the separation and quantitation of impurities in nitrogen. This system consists of a two-stream selection in which H2 and O2 are analyzed by a TCD-17A. Analysis time is approximately 7 minutes. Must include a data processor or data station. GC-14A N2 Contaminants Analyzer Part Number: Analytes: H2, O2 Columns: 1 packed This turnkey analyzer is dedicated to the separation and quantitation of impurities in nitrogen. This system consists of a two-stream selection in which H2, and O2 are analyzed by a TCD-14A. Analysis time is approximately 7 minutes. Must include a data processor or data station. GC-8A N2 Contaminants Analyzer Part Number: Analytes: H2, O2 Columns: 1 packed This turnkey analyzer is dedicated to the separation and quantitation of impurities in nitrogen. This system consists of a two-stream selection in which H2, and O2 are analyzed by a TCD-8A. Analysis time is approximately 7 minutes. Must include a data processor or data station
11 Environmental and Safety GC-17A TOGAS Method: ASTM 3612 Part Number: Analytes: H2, O2, N2, CH4, CO, CO2, C2H4, C2H6, C2H2 Detectors: PDD/FID/Methanizer. Could substitute TCD for PDD Columns: 2 Capillary The TOGAS GC-17A Dissolved Gas in Transformer Oil Analysis System offers a turnkey system for the analysis of H2, O2, N2, CH4, CO, CO2, C2H6, C2H4, and C2H2 in mineral spirit-based transformer oil via direct injection. Meets ASTM D requirements. Features a GC-17A with FID and PDD detectors, valves, columns, methanizer, and patented oil stripper. System operation is completely automated. Analysis time is approximately 5-10 minutes depending on backflush of high concentrated samples. Must GC-14A TOGAS Method: ASTM 3612 Part Number: Analytes: H2, O2, N2, CH4, CO, CO2, C2H4, C2H6, C2H2 Detectors: PDD/FID/Methanizer Columns: 6 packed The TOGAS-14 Transformer Oil Gas Analysis System is completely turnkey, having been calibrated and tuned prior to shipment. The GC-14A TOGAS gives accurate measurement of dissolved gases which include H2, O2, N2, CH4, CO, CO2, C2H6, C2H4, and C2H2 in mineral spirit-based transformer oil via direct injection. Meets ASTM D requirements. Features a GC-14A with FID and TCD detectors, valves, columns, methanizer, and patented oil stripper. System operation is completely automated. Analysis time is approximately 25 minutes. Must include a data processor or data station. GC-14A Greenhouse Gas Analyzer Part Number: Analytes: N2O, CH4, CO2 in air Detectors: ECD/FID This model quantitates atmospheric trace gases, CO2, CH4, N2O, in air matrix. This turnkey system is equipped with 2 sample loops, one delivers the sample to an ECD for N2O and CO2 detection and the other delivers the sample to an FID for the detection of CH4. Generally, this system represents a useful and efficient tool for a large number of studies on greenhouse gases. Analysis time is approximately 5 minutes. Must include a data processor or data station. GC-17A Mine Gas Analyzer Part Number: Analytes: H2, O2, N2, CH4, CO, CO2, C2H4, C2H6, C2H2 Detectors: PDD/FID/Methanizer Columns: 2 capillary The GC-17A Mine Gas System offers a turnkey system for the analysis of H2, O2, N2, CH4, CO, CO2, C2H6, C2H4, and C2H2. This analyzer is similar to the GC-17A TOGAS. Features a GC-17A with FID and PDD detectors, valves, columns, and methanizer. System operation is completely automated. Analysis time is approximately 5-10 minutes depending on backflush of molesieve 5A column. GC-14A Mine Gas Analyzer Part Number: Analytes: H2, O2, N2, CH4, CO, CO2, C2H4, C2H6, C2H2 /FID/Methanizer Columns: 6 packed The GC-14A Mine Gas System offers a turnkey system for the analysis of H2, O2, N2, CH4, CO, CO2, C2H6, C2H4, and C2H2. This analyzer is similar to the GC-14A TOGAS. Features a GC-14A with FID and TCD detectors, valves, columns, and methanizer. System operation is completely automated. Analysis time is approximately 25 minutes. GC-14A Mud Logging, Well Gas Sampling Analyzer Part Number: Analytes: Stream 1 Hydrocarbons- (Total baseline measurement). Stream 2 C1-C6 Detectors: 2 FID s Columns: 1 packed GC-14A Fuel Cell Analyzer Part number: Analytes: H2, O2, N2, CH4, CO, CO2, Light Hydrocarbons /FID/Methanizer This turnkey system is designed for the analysis of gases produced from a catalytic reformer during the fuel cell process. The system provides valuable information for the design, performance and optimization of the reformer operation. The system determines H2, O2, N2, CH4, CO, CO2 and other key species. The system consists of a GC-14 with TCD and FID with methanizer, along with the valves and columns required for the application. GC-2010 Methane in Exhaust Analyzer by SAE J1511 Method: SAE J1511 Part Number: Analytes: CH4 This turnkey system is constructed to the specifications of Society of Automotive Engineers J1145. The analyzer separates methane from the other constituents of an exhaust gas sample. The concentration of methane is determined with an FID with a detection of approximately 1ppm. A complete cycle, from injection of one sample to injection of a second sample, can be made in 30 seconds. GC-17A Methane in Exhaust Analyzer by SAE J1511 Method: SAE J1511 Part Number: Analytes: CH4 This turnkey system is constructed to the specifications of Society of Automotive Engineers J1145. The analyzer separates methane from the other constituents of an exhaust gas sample. The concentration of methane is determined with an FID with a detection of approximately 1ppm. A complete cycle, from injection of one sample to injection of a second sample, can be made in 30 seconds. GC-14A Methane in Exhaust Analyzer by SAE J1511 Method: SAE J1511 Part Number: Analytes: CH4 This turnkey system is constructed to the specifications of Society of Automotive Engineers J1145. The analyzer separates methane from the other constituents of an exhaust gas sample. The concentration of methane is determined with an FID with a detection of approximately 1ppm. A complete cycle, from injection of one sample to injection of a second sample, can be made in 30 seconds. GC-17A with AOC20i Autoinjector and AOC20s 150 Sample Carousel
12 Ordering Information How to Order Phone: For convenient ordering, use our toll-free number; , ext Mail: Mail your order to: SHIMADZU 7102 Riverwood Drive Columbia, MD Fax: Fax your purchase order to: Online: Visit our website, for more information or to contact your local sales office/representative. When you order, be sure to include: Purchase order number Your billing address Your shipping address Our catalog number and the product description Your name and telephone number Terms We welcome all orders of any size. Terms of payment are net 30 days. Returns Returns of any products must be authorized in advance. Please contact SHIMADZU for a return authorization number and forwarding instructions. All claims must be made within 60 days of shipping. Report shipping damage to carrier. Keep containers and packaging materials until inspection has been made. Warranty Information presented in this catalog is correct and reliable to the best of our knowledge and belief, but is not guaranteed to be so. SHIMADZU shall not, under any circumstances, be held liable for any incidental, consequential or compensatory damage arising from the use of, or in conjunction with its products. The maximum liability which can be assumed by SHIMADZU shall be limited to the invoice price of the product. Order today! Call or log-on to for more information. 20
Chemical Analysis. Natural Gas Analyzer. A Family of optimized GC Solutions. Gas Chromatography. think forward
Chemical Analysis Natural Gas Analyzer A Family of optimized GC Solutions think forward Gas Chromatography Bruker Natural Gas Analyzers Natural gas is bought and sold as a bulk commodity with price based
More informationBTU ANALYSIS USING A GAS CHROMATOGRAPH
BTU ANALYSIS USING A GAS CHROMATOGRAPH By Joseph E. Landes Southern Petroleum Laboratories, Inc. Technical Director Hydrocarbon and Field Services 8820 Interchange Drive Houston, Texas 77054 Introduction
More informationTransformer Oil Gas Analysis
Get on the Analyzer FAST TRACK Transformer Oil Gas Analysis Helping customers protect the environment! 1 Why Analyzers Value to Customers Alleviates Resource Pressure Facilitates Configuration Use Advanced
More informationProcess Instrumentation
Process Instrumentation Analysis by Gas Chromatography Engineered Solutions, Guaranteed Results. WASSON - ECE INSTRUMENTATION Process Gas Chromatography Features of Process Chromatographs Agilent 7890A
More information1.1 This test method covers the qualitative and quantitative determination of the content of benzene and toluene in hydrocarbon wax.
Standard Method for Analysis of Benzene and Toluene Content in Hydrocarbon Waxes by Headspace Gas Chromatography EWF METHOD 002/03 (Version 1 Reviewed 2015) 1 Scope 1.1 This test method covers the qualitative
More informationC184-E014D GC-2014. Shimadzu Gas Chromatograph System
C184-E014D GC-2014 Shimadzu Gas Chromatograph System Big Performance & Small Space GC-2014 GC-2014 Shimadzu Gas Chromatograph System High Performance and Expandability Merged at a higher level High Performance
More informationGC METHODS FOR QUANTITATIVE DETERMINATION OF BENZENE IN GASOLINE
ACTA CHROMATOGRAPHICA, NO. 13, 2003 GC METHODS FOR QUANTITATIVE DETERMINATION OF BENZENE IN GASOLINE A. Pavlova and R. Ivanova Refining and Petrochemistry Institute, Analytical Department, Lukoil-Neftochim-Bourgas
More informationPLOT Columns. Top: Bob Langford, GC Column Manufacturing Technician Bottom: Stephanie Sunner, Customer Service Representative
PLOT Columns Top: Bob Langford, GC Column Manufacturing Technician Bottom: Stephanie Sunner, Customer Service Representative PLOT Column Selection 93 Features & Benefits of Restek PLOT Columns Features
More informationCHROMOCTANE O N LINE ANALYZER
GECIL Process GT instruments CHROMOCTANE O N LINE ANALYZER ASTM D6733 DHA and RON and MON on line GC for Reformer unit Automatic Chromatographic system for analysis of naphta feeds and reforming gasolines
More informationADVANCEMENTS IN MICRO GAS CHROMATOGRAPHY (GC)
ADVANCEMENTS IN MICRO GAS CHROMATOGRAPHY (GC) 1 Fast Analysis of C1 to C8 hydrocarbons for mud logging applications within 2 minutes using a temperature programmable Micro GC Fusion NEN GAS2015 Debbie
More informationFundamentals of Gas Chromatography
Application Note Oil & Gas Fundamentals of Gas Chromatography Figure 1 - The Function Components of a Gas Chromatograph Process Line Sample System Chromatograph Oven GC Controller Probe Sample Return Slip
More informationProcess gas chromatographs. Measurement made easy. Compliance Solutions for 40CFR60 Subpart Ja
Process gas chromatographs. Measurement made easy Compliance Solutions for 40CFR60 Subpart Ja Introduction ABB offers a proven analytical solution to completely meet your Refinery Flare Monitoring requirements
More informationEPA Method RSK 175 Dissolved Gasses in Water Matrices using the Teledyne Tekmar HT3 Headspace Analyzer. HT3 Application Note.
EPA Method RSK 175 Dissolved Gasses in Water Matrices using the Teledyne Tekmar HT3 Headspace Analyzer HT3 Application Note Introduction The analysis of dissolved gases in ground water is important in
More informationThe Relation Between Gasoline Quality, Octane Number and the Environment
MH1 The Relation Between Gasoline Quality, Octane Number and the Environment Rafat Assi National Project Manager Jordan s Second National Communications on Climate Change (www.snc.gov.jo) Presented at
More informationSeries 2. Air Server. Options for UNITY 2. A robust, cryogen-free solution for round-the-clock on-line air monitoring
Series 2 Air Server Options for UNITY 2 A robust, cryogen-free solution for round-the-clock on-line air monitoring Series 2 Air Server Three- and eight-channel options for UNITY offering round-the-clock
More informationGas Chromatograph GC Consumables. p/n: 220-94898-02
Gas Chromatograph GC Consumables p/n: 220-94898-02 Diag. # 1) Septum Nut 2) Needle Guide 3) Septum 4) Injection Port A Assy 5) O-ring for Glass Insert 6) Glass Insert 7) Gold Gasket 8) Capillary Adaptor
More informationLecture Chromo-3: Gas Chromatography. CHEM 5181 Fall 2004 Mass Spectrometry & Chromatography. Jessica Gilman and Prof. Jose-Luis Jimenez CU-Boulder
Lecture Chromo-3: Gas Chromatography CHEM 5181 Fall 2004 Mass Spectrometry & Chromatography Jessica Gilman and Prof. Jose-Luis Jimenez CU-Boulder Outline Introduction Instrument overview Carrier gas Sample
More informationMATHESON REFINERY PROGRAM for Specialty Gas Supply. Experience the MATHESON Commitment to Supply Chain Excellence
MATHESON REFINERY PROGRAM for Specialty Gas Supply MATHESON REFINERY PROGRAM for Specialty Gas Supply MATHESON is a single source for industrial, medical, specialty, and electronics gases as well as gas
More informationOn-line Dissolved Gas Analysis
On-line Dissolved Gas Analysis accord. to IEC 567/ASTM 3612 Online-Monitoring of transformers Automatic on-line analysis of 11 gases The analysis is done in 2 steps with high selectivity and accuracy fully
More informationCRYOCOOLER CONTAMINATION STUDY. S.W.K. Yuan, D.T.Kuo, and A.S. Loc. BEI Technologies, Cryocooler Group Sylmar, CA 91342 ABSTRACT
CRYOCOOLER CONTAMINATION STUDY S.W.K. Yuan, D.T.Kuo, and A.S. Loc EI Technologies, Cryocooler Group Sylmar, CA 91342 ASTRACT Eliminating or reduction of contamination is essential for the success of cryocoolers
More informationAnnex to the Accreditation Certificate D PL 17640 01 00 according to DIN EN ISO/IEC 17025:2005
Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D PL 17640 01 00 according to DIN EN ISO/IEC 17025:2005 Period of validity: 05.06.2015 to 04.11.2018 Holder of certificate: Haltermann
More informationAC DHA Solutions. Detailed Hydrocarbon Analysis of Light Petroleum Streams & Light End in Crude Oils. ASTM D 5134, D 6729, D 6730, D 6733 Compliance
AC DHA Solutions Detailed Hydrocarbon Analysis of Light Petroleum Streams & Light End in Crude Oils ASTM D 5134, D 6729, D 6730, D 6733 Compliance Signal Alignment Automated with LineUp TM Tool Compatible
More informationTypical commercial laboratory turn around - two days to two weeks In-house hexane/gravimetric several hours Results in the discharge of effluent
On-site Oil and Grease Measurements in under a Minute Sandy Rintoul Wilks Enterprise, Inc. IPEC Booth #3 srintoul@wilksir.com www.wilksir.com Portable Field or Lab Analyzer Results in < 1 minute Rugged
More informationChromatograph Maintenance and Troubleshooting Class # 5050
Chromatograph Maintenance and Troubleshooting Class # 5050 Shane Hale Business Development Manager Emerson Process Management Gas Chromatographs Division 5650 Brittmoore Drive Houston, TX 77041 USA Introduction
More informationN O T E S. Environmental Forensics. Identification of Natural Gas Sources using Geochemical Forensic Tools. Dispute Scenarios
Environmental Forensics N O T E S V o l u m e 2 9 Identification of Natural Gas Sources using Geochemical Forensic Tools By Paul Boehm, Ph.D. and Tarek Saba, Ph.D. F o r m o r e i n f o r m a t i o n o
More informationPilot Gasifier Producer Gas Analysis and Measurement Arrangements in. University of Applied Sciences
Pilot Gasifier Producer Gas Analysis and Measurement Arrangements in Sievi Laboratory Kari Pieniniemi, Researcher, Centria University of Applied Sciences 1 2 MEASURING LINE AT SIEVI LABORATORY 3 MEASURING
More informationFerda ORHUN Mineral Research and Exploration Institute of Turkey
GAS CHROMATOGRAPHY, EXPERIMENTAL STUDIES ON THE FLOW RATE EFFECTS OF CARRIER GAS AND APPLICATION OF THE METHOD TO HYDROCARBON ANALYSIS OF SOME NATURAL GASES IN TURKEY Ferda ORHUN Mineral Research and Exploration
More informationCapillary and Packed Gas Chromatograph
Capillary and Packed Gas Chromatograph C184-E014G High Performance and Expandability Merged at a higher level Capillary and Packed Gas Chromatograph High Performance Superior Performance Improved design
More informationHow To Run A Gas Plant
MATHESON Petrochemical Industry Program for Specialty Gas Supply MATHESON Petrochemical Industry Program for Specialty Gas Supply MATHESON is a single source for industrial, medical, specialty, and electronics
More informationDraeger-Tubes and accuro Pump
Draeger-Tubes and accuro Pump Trusted Technology that s ahead of its time Accurate Easy to read Flexible Fast Specific Easy to use Maintenance free Multi-Gas Detector accuro pump One handed operation What
More informationGC/MS Considerations for Fracking Gases and Water. Dr. Harold McNair Virginia Tech Blacksburg, VA. hmcnair@vt.edu
GC/MS Considerations for Fracking Gases and Water Dr. Harold McNair Virginia Tech Blacksburg, VA. hmcnair@vt.edu 1 Outline What is fracking? Energy, Economics, Environmental Factors Chromatographic Considerations
More information83 to 87% carbon 11-15% hydrogen 0.1-7% sulphur 0.06-1.5% oxygen 0.1-0.5% nitrogen
Petroleum chemistry rude is the name for a liquid mixture of different hydrocarbon connections found in the earth. Petroleum, strictly speaking is crude oil, but it is used to describe all kinds of hydrocarbons.
More informationHolcim EMR List of EN Standards and VDI Guidelines usable for Discontinuous Measurements in Cement Plants
Holcim EMR List of EN Standards and VDI Guidelines usable for Discontinuous Measurements in Cement Plants Version 2004-01 / August 2004 (HGRS-JW-04-25s) HGRS-CTS/MT J. Waltisberg SUMMARY ( ) shall not
More informationProcess gases for analytical applications
Process gases for analytical applications Analysis is the art of separating a substance into its constituents and making qualitative and quantitative determinations about it The field of analytical application
More informationMERCURY REMOVAL FROM NATURAL GAS AND LIQUID STREAMS ABSTRACT. Giacomo Corvini, Julie Stiltner and Keith Clark UOP LLC Houston, Texas, USA
MERCURY REMOVAL FROM NATURAL GAS AND LIQUID STREAMS Giacomo Corvini, Julie Stiltner and Keith Clark UOP LLC Houston, Texas, USA n ABSTRACT Mercury is often present in natural gas, petrochemical and some
More informationElemental analyzer multi EA 5000
Elemental analyzer multi EA 5000 Analytik Jena AG Konrad-Zuse-Str. 1 07745 Jena/Germany www.analytik-jena.com info@analytik-jena.com 1/6 multi EA 5000 The multi EA 5000 is a powerful elemental analyzer
More informationHands-on Workshop on Advanced Hydrocarbon Analysis July 23, 2015
Hands-on Workshop on Advanced Hydrocarbon Analysis July 23, 2015 Fast Analysis of Natural Gas and Fuel Gas Using Agilent 490 Micro GC - David Ramby, Quantum Analytics Quantum Analytics Value-added distributor
More informationHEXANES. Insoluble in water, soluble in ether, alcohol, and acetone. Neutral to methyl orange (ph indicator) Not more than 0.
HEXANES Prepared at the 51st JECFA (1998), published in FNP 52 Add 6 (1998) superseding specifications prepared at the 14th JECFA (1970), published in NMRS 48B (1971) and in FNP 52 (1992). ADI "limited
More informationGas Chromatography. Gas Chromatograph
Gas Chromatography Gas Chromatograph Chromatography: Separate analytes in a mixture with a resolution 1.5 in the shortest amount of time and detection of separated components. 1 = m.p. 6 2 4 5 3 Gas supplies
More informationThermo Scientific ConFlo IV Universal Interface
m a s s s p e c t r o m e t r y Thermo Scientific ConFlo IV Universal Interface The Universal Interface Part of Thermo Fisher Scientific ConFlo IV Universal Interface The Universal Interface The development
More informationASimple Guide to Oil Refining
ASimple Guide to Oil Refining We all know that motor oil and gasoline come from crude oil. What many people do not realize is that crude oil is also the starting point for many diverse products such as
More informationGerhard Schomburg. Gas Chromatography. A Practical Course. -«WTM-JY// ^ Weinheim New York. VCH XJ Basel Cambridge
Gerhard Schomburg Gas Chromatography A Practical Course -«WTM-JY// ^ Weinheim New York VCH XJ Basel Cambridge Contents 1 The Role of Gas Chromatography Among Other Methods of Instrumental Analysis 1 2
More informationTHERMAL DESORPTION. Introduction and Principles. Focusing on Volatiles
THERMAL DESORPTION Introduction and Principles Thermal Desorption Thermal desorption is a simple extension of the technique of gas chromatography (GC) It involves the use of heat and a flow of inert gas
More informationCOAL MINES TECHNICAL SERVICES, GAS DETECTION RELATED SERVICES FOR MINES RESCUE
COAL MINES TECHNICAL SERVICES, GAS DETECTION RELATED SERVICES FOR MINES RESCUE Peter Mason Manager, Coal Mines Technical Services, a division of Mines Rescue Pty Ltd, Australia Establishment of CMTS Initially
More informationShimadzu Simulated Distillation Gas Chromatograph System C184-E030
Shimadzu Simulated Distillation Gas Chromatograph System C184-E030 Meets All Simulated Distillation Gas Chromatograph Standards - Provides Highly Accurate Analysis Results with Excellent Reproducibility-
More information1. Standard conditions are 29.92 in. Hg (760 mm Hg, 14.696 psia) and 68 F (20 C).
INTRODUCTION Emission Monitoring Inc. DETERMINING F-FACTORS FROM GAS CHROMATOGRAPHIC ANALYSES Roger T. Shigehara Emission Monitoring Incorporated Howard F. Schiff TRC Environmental Corporation EPA Method
More informationSCION SQ Series GC-MS
SCION SQ Series GC-MS The Gas Chromatographers Detector SCION SQ TM GC-MS The SCION SQ series GC-MS systems combine innovative engineering with detailed cutomer requirements to produce a truly innovative
More informationTracer Detection Systems
Tracer Detection Systems WASSON ECE Engineered Solutions, Guaranteed Results. Wasson-ECE Tracer Analysis System The industry standard for low level perfluoronated tracer analysis. Tracer tagging technology
More informationCHAPTER 7 THE DEHYDRATION AND SWEETENING OF NATURAL GAS
CHAPTER 7 THE DEHYDRATION AND SWEETENING OF NATURAL GAS Natural gases either from natural production or storage reservoirs contain water, which condense and form solid gas hydrates to block pipeline flow
More informationGas Separations: A Comparison of GasPro and Aluminum Oxide PLOT Columns for the Separation of Highly Volatile Compounds
Gas Separations: Comparison of GasPro and luminum Oxide PLOT Columns for the Separation of Highly Volatile Compounds Daniel W. rmstrong* Department of Chemistry, University of Missouri-Rolla, Rolla, MO
More informationFluid & Gas Properties
Fluid & Gas Properties FLUID DENSITY Density is the ratio of mass to volume. In English, units density is expressed in pounds mass/cubic foot (lbm/ft 3 ). The symbol for density is ρ. Density is usually
More informationTheory and Instrumentation of GC Introduction
Theory and Instrumentation of GC Introduction i Wherever you see this symbol, it is important to access the on-line course as there is interactive material that cannot be fully shown in this reference
More informationAddressing the World Helium Shortage For Gas Chromatography
Addressing the World Helium Shortage For Gas Chromatography Helium Conservation and Converting GC Methods to Nitrogen and Hydrogen Carrier Gas James D. McCurry, Ph.D. Senior Scientist Agilent Technologies
More informationGas Chromatography. Let s begin with an example problem: SPME head space analysis of pesticides in tea and follow-up analysis by high speed GC.
Gas Chromatography Let s begin with an example problem: SPME head space analysis of pesticides in tea and follow-up analysis by high speed GC. Samples in 10mL sealed glass vials were placed in the MPS-2
More informationGas Detection for Refining. HA University
Gas Detection for Refining HA University Refinery Process and Detection Needs Refining i Crude Oil Final Products Coke Asphalt Waxes, Lubricating Oils and Greases Kerosene, Jet Fuel, Diesel Fuel, Home
More informationBalancing chemical reaction equations (stoichiometry)
Balancing chemical reaction equations (stoichiometry) This worksheet and all related files are licensed under the Creative Commons Attribution License, version 1.0. To view a copy of this license, visit
More informationFiscal Measurement Natural Gas
White Paper FSG-WP-0012 February 2014 Fiscal Measurement Natural Gas Fiscal Measurement How much? Fiscal Measurement must not be confused with Custody Transfer; in fact, fiscal measurement is a more general
More informationMulti-elemental determination of gasoline using Agilent 5100 ICP-OES with oxygen injection and a temperature controlled spray chamber
Multi-elemental determination of gasoline using Agilent 5100 ICP-OES with oxygen injection and a temperature controlled spray chamber Application note Energy & chemicals, petrochemicals Authors Elizabeth
More informationCOMPRESSED NATURAL GAS (CNG) UTILIZATION POLICY TO IMPROVE URBAN AIR QUALITY by EDI WIBOWO and YUSEP K. CARYANA
COMPRESSED NATURAL GAS (CNG) UTILIZATION POLICY TO IMPROVE URBAN AIR QUALITY by EDI WIBOWO and YUSEP K. CARYANA Research and Development Centre for Oil and Gas Technology LEMIGAS Jakarta 12230, Indonesia.
More informationNatural Gas Processing Solutions Using the 700XA Gas Chromatograph
Application Note Oil & Gas Natural Gas Processing Solutions Using the 700XA Gas Chromatograph Optimizing the efficiency and profitability of a natural gas processing plant requires responding to the changing
More informationSULFUR COMPOUNDS IN PETROLEUM HYDROCARBON STREAMS
Petroleum & Coal ISSN 1337-7027 Available online at www.vurup.sk/petroleum-coal Petroleum & Coal 54 (1) 9-13, 2012 SULFUR COMPOUNDS IN PETROLEUM HYDROCARBON STREAMS Antoaneta Pavlova, Pavlina Ivanova,
More informationDevelopment of large-scale H 2 storage and transportation technology with Liquid Organic Hydrogen Carrier (LOHC)
Development of large-scale storage and transportation technology with Liquid Organic Hydrogen Carrier (LOHC) Yoshimi Okada 1, Mitsunori Shimura 2 Principal researcher, Technology Development Unit, Chiyoda
More informationProcess Gas Monitoring in Petroleum Refineries
Application Note Refining Process Gas Monitoring in Petroleum Refineries Application Emerson offers several Rosemount Analytical gasanalyzer technologies to meet the process control and stream purity monitoring
More informationBakken Crude Oil & Response Considerations. Objectives
Bakken Crude Oil & Response Considerations UNITED STATES EPA Region 10 Emergency Management Program December 2014 NWEC Meeting Portland, Oregon Objectives Using EPA Bakken preparedness case study, objective
More information23 The Thermal Conductivity Detector
23 The Thermal Conductivity Detector General Information TCD pneumatics Conditions that prevent the detector from operating Filament passivation Carrier, reference, and makeup gas Negative polarity Analyzing
More informationAn Advanced Base Deactivated Capillary Column for analysis of Volatile amines Ammonia and Alcohols.
An Advanced Base Deactivated Capillary Column for analysis of Volatile amines Ammonia and Alcohols. Jaap de Zeeuw, Ron Stricek and Gary Stidsen Restek Corp Bellefonte, USA To analyze basic compounds at
More informationChemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography
Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography INTRODUCTION The analysis of soft drinks for caffeine was able to be performed using UV-Vis. The complex sample
More informationGas Chromatography monitors Green House Gas (GHG) emission from flares
Gas Chromatography monitors Green House Gas (GHG) emission from flares International regulations increasingly call for on-line monitoring of Green House Gas emissions from flare stacks Flaring produces
More informationBioremediation. Biodegradation
Bioremediation A technology that encourages growth and reproduction of indigenous microorganisms (bacteria and fungi) to enhance biodegradation of organic constituents in the saturated zone Can effectively
More informationFacts About. Industrial gases for better injection molding. This article appeared in the trade journal Kunststoffe plast europe, issue 12/2004.
Facts About. Industrial gases for better injection molding. This article appeared in the trade journal Kunststoffe plast europe, issue 12/2004. 2 Industrial gases for better injection molding Gas injection
More informationBackground Information
1 Gas Chromatography/Mass Spectroscopy (GC/MS/MS) Background Information Instructions for the Operation of the Varian CP-3800 Gas Chromatograph/ Varian Saturn 2200 GC/MS/MS See the Cary Eclipse Software
More informationSulphur in Nigerian Diesel
Sulphur in Nigerian Diesel Aminu Jalal National Automotive Council, Abuja, Nigeria, At National Sensitisation Workshop on Sulphur Reduction in Vehicle Fuels, Lome, Togo, 17-18 June 2008 Outline Introduction
More informationPetrochemical Industry Ethylene Plant
Petrochemical Industry Ethylene Plant Application note The Ethylene Plant provides the base feedstock for a number of critical products used throughout the petrochemical industry. Compounds ranging from
More informationUOP Adsorbents COMPREHENSIVE PORTFOLIO TO REMOVE CONTAMINANTS FROM A VARIETY OF SOURCES. UOP Adsorbent Solutions
UOP Adsorbents COMPREHENSIVE PORTFOLIO TO REMOVE CONTAMINANTS FROM A VARIETY OF SOURCES UOP Adsorbent Solutions When you invest in UOP Adsorbents, you gain more than simply a contaminant removal product.
More informationHalogen Free: What, Why and How. Presented by : Jim Cronin Environmental Monitoring and Technologies, Inc.
Halogen Free: What, Why and How Presented by : Jim Cronin Environmental Monitoring and Technologies, Inc. We will discuss What are Halogens and how we interact with them. Why Halogens, within consumer
More informationENVIRONMENTAL STANDARDS FOR PETROLEUM OIL REFINERIES EMISSIONS. Standards for emissions from furnaces, boilers and Power Plant
ENVIRONMENTAL STANDARDS FOR PETROLEUM OIL REFINERIES EMISSIONS Standards for emissions from furnaces, boilers and Power Plant S. Parameter Limiting concentration in mg/nm 3, unless stated Existing refineries
More informationAMD Analysis & Technology AG
AMD Analysis & Technology AG Application Note 120419 Author: Karl-Heinz Maurer APCI-MS Trace Analysis of volatile organic compounds in ambient air A) Introduction Trace analysis of volatile organic compounds
More informationSolutions. Integrated Analyzer Systems & Services Your Global Partner For Customized Analytical Solutions
Solutions Integrated Analyzer Systems & Services Your Global Partner For Customized Analytical Solutions BU 10A02A01-01E-A www.yokogawa.com/us/ia/analytical/measurementation/home.htm Core Expertise Measurementation,
More informationGas Chromatography monitors Green House Gas (GHG) emission from flares
Process Analytics Gas Chromatography monitors Green House Gas (GHG) emission from flares International regulations increasingly call for on-line monitoring of Green House Gas emissions from flare stacks
More informationHydrogen as an alternative to Helium for gas chromatography.
Application Note Gas Chromatography. Application Note for Specialty Gases. as an alternative to for gas chromatography. Author: Peter Adam Linde AG, Linde Gas Division Seitnerstrasse 70, 82049 Pullach,
More informationDissolved Gas Analysis Guide for Transformers Filled with Beta Fluid
DSI Ventures, Inc. PHONE: (903) 526-7577 FAX: (903) 526-0021 www.dsiventures.com Dissolved Gas Analysis Guide for Transformers Filled with Beta Fluid Introduction Analysis of dissolved gases in transformer
More informationWorld s Best Oil in Water Analyzers
World s Best Oil in Water Analyzers Advanced Water Measurement and Analysis Advanced Sensors Ltd is the leading global supplier of Oil in Water analyzers to the Oil and Gas Industries. We provide innovative
More informationBringing Innovations to Standards AC Analytical Controls by PAC All In One Biodiesel Analyzer
Bringing Innovations to Standards AC Analytical Controls by PAC All In One Biodiesel Analyzer www.paclp.com Background Biodiesel offers an alternative to fossil diesel fuel & contributes to the reduction
More informationFACE GASOLINES AND BLENDS WITH ETHANOL: DETAILED CHARACTERIZATION OF PHYSICAL AND CHEMICAL PROPERTIES
CRC Report No. AVFL-24 FACE GASOLINES AND BLENDS WITH ETHANOL: DETAILED CHARACTERIZATION OF PHYSICAL AND CHEMICAL PROPERTIES July 2014 COORDINATING RESEARCH COUNCIL, INC. 3650 MANSELL ROAD SUITE 140 ALPHARETTA,
More informationACETALDEHYDE and ISOVALERALDEHYDE (Gas Chromatography)
ACETA.02-1 ACETALDEHYDE and ISOVALERALDEHYDE (Gas Chromatography) PRINCIPLE Isovaleraldehyde (IVA) and acetaldehyde are released from the syrup with the aid of dilute phosphoric acid and heat. The liberated
More informationSynfuels GASRICH Transport Light Gas Technology
Synfuels GASRICH Transport Light Gas Technology Storage and Transport of Light Gas and LNG Blends Abstract The Liquefied Natural Gas (LNG) industry is well established and growing. Recently depressed Natural
More informationThe Agilent 7890A Gas Chromatograph All the elements for perfect chemistry. Our measure is your success.
The Agilent 7890A Gas Chromatograph All the elements for perfect chemistry. Our measure is your success. Introducing the Agilent 7890A Gas Chromatograph. Step up to a higher level of GC reliability, productivity
More informationNatural Gas Information Contents
Natural Gas Information Contents What is natural gas Natural Gas Components Physical Properties of Natural Gas Different Forms of Natural Gas The Use of Natural Gas Co-generation System Natural Gas and
More informationTHE BASICS Q: What is VOC? Q: What are flashing losses/voc emissions from hydrocarbon storage tanks? - 1 -
Calculation of Flashing Losses/VOC Emissions from Hydrocarbon Storage Tanks THE BASICS Q: What is VOC? A: VOC is an acronym that stands for Volatile Organic Compounds. VOC are components of hydrocarbon
More informationGlossary of Energy Terms
Glossary of Energy Terms A API gravity A measure of the weight of hydrocarbons according to a scale established by the American Petroleum Institute. Crude oils with higher values are lighter and tend to
More informationAMMONIA AND UREA PRODUCTION
AMMONIA AND UREA PRODUCTION Urea (NH 2 CONH 2 ) is of great importance to the agriculture industry as a nitrogen-rich fertiliser. In Kapuni, Petrochem manufacture ammonia and then convert the majority
More informationPage 1. 6. Which hydrocarbon is a member of the alkane series? (1) 1. Which is the structural formula of methane? (1) (2) (2) (3) (3) (4) (4)
1. Which is the structural formula of methane? 6. Which hydrocarbon is a member of the alkane series? 7. How many carbon atoms are contained in an ethyl group? 1 3 2 4 2. In the alkane series, each molecule
More informationOptimization of Natural Gas Processing Plants Including Business Aspects
Page 1 of 12 Optimization of Natural Gas Processing Plants Including Business Aspects KEITH A. BULLIN, Bryan Research & Engineering, Inc., Bryan, Texas KENNETH R. HALL, Texas A&M University, College Station,
More informationModule 3: Liquid Fossil Fuel (Petroleum) Lecture 17: Evaluation of crude
1 P age Module 3: Liquid Fossil Fuel (Petroleum) Lecture 17: Evaluation of crude 2 P age Keywords: Evaluation, characterization factor, TBP, ASTM, EFV 3.2 Evaluation of crude The assessment of a crude
More informationSAMPLE CHAPTERS UNESCO EOLSS NATURAL GAS PROCESSING. H. K. Abdel-Aal National Research Center (NRC), Cairo, Egypt
NATURAL GAS PROCESSING H. K. Abdel-Aal National Research Center (NRC), Cairo, Egypt Keywords: sour natural gas, gas sweetening, gas dehydration, amines, glycols, hydrates, hydrogen sulfide, NGL, cryogenic
More informationAMBIENT AIR QUALITY MONITORING SYSTEM. Air Quality Monitoring... Easier. Faster. Better. www.chemtrols.com
AMBIENT AIR QUALITY MONITORING SYSTEM Air Quality Monitoring... Easier. Faster. Better. www.chemtrols.com AMBIENT AIR QUALITY MONITORING FROM CHEMTROLS Chemtrols is a leading solution provider in the field
More informationOil and Gas Air Quality Regulations and Permitting
Oil and Gas Air Quality Regulations and Permitting Adam Berig Olsson Associates Colorado Springs Oil and Gas Committee Presentation February 2012 Who Regulates Air Quality? United States Environmental
More informationTHERMAL ANALYSIS. Measurement for Transition Heat of Plastics. - According to JIS K 7121-1987 -
Page 1 of 7 THERMAL ANALYSIS T91 Measurement for Transition Heat of Plastics - According to JIS K 7121-1987 - Heat characteristics of high polymers, such as transition and decomposition, are measured by
More informationMolecular Sieve Adsorbents
Adsorption Technologies: our work our life our passion. Molecular Sieve Adsorbents Zeochem Molecular Sieve Adsorbents Zeochem, a manufacturer of high quality molecular sieves and chromatography gels, was
More information