Advanced Test Equipment Rentals ATEC (2832)
|
|
|
- Jesse Jones
- 10 years ago
- Views:
Transcription
1 Established 1981 dvanced Test Equipment Rentals TEC (2832) gilent PN Series Microwave Network nalyzers Configuration Guide PN E8362C PN E8363C PN E8364C PN E8361C 10 MHz to 20 GHz 10 MHz to 40 GHz 10 MHz to 50 GHz 10 MHz to 67 GHz This guide describes standard configurations, for the PN (E836xC) Series microwave network analyzers. This guide should be used with the gilent PN family data sheets for a complete description of these analyzers. For applications, measurement accessories, and general accessories please see gilent PN Family Network nalyzers Configuration Guide, part number EN.
2 gilent offers the followg options for all PN family network analyzers Certification options Commercial calibration certification with test data (Option UK6) Complete set of measurements which tests unit to manufacturer s published specifications. Includes calibration label, calibration certificate, and data report. Conforms to ISO ISO compliant calibration (Option 17) Complete set of measurements which tests unit to manufacturer s published specifications. Includes calibration label, ISO calibration certificate, and data report, measurement uncertaties and guardbands on all customer specifications. Conforms to ISO and ISO NSI Z540 compliant calibration (Option 6J) Complete set of measurements which tests unit to manufacturer s published specifications. Includes pre- and post-adjustment data with measurement uncertaty formation compliant to the NSI/NCSL Z540 standard. Warranty and service 1-, 3-, and 5-year warranty and service plans are available at the time of strument purchase. Standard warranty is 1 year. Documentation The PN Series struments are equipped with an Onle Help system available with the strument the followg languages: English, Japanese, Chese, German, Spanish, and French. Service guides and the Onle Help system are available on the web: Calibration Software Licenses Perpetual license for built- performance test software for gilent clusive cal (Option 897) dds built- performance testg and calibration software for self-mataers. Requires additional equipment. See the analyzer s Service Guide for more formation on equipment required. Perpetual license for built- performance test software for Standards compliant cal (Option 898) dds built- performance testg and calibration software for self-mataers. Requires additional equipment. See the analyzer s Service Guide for more formation on equipment required. 2
3 E8362C 10 MHz to 20 GHz E8363C 10 MHz to 40 GHz E8364C 10 MHz to 50 GHz E8361C 10 MHz to 67 GHz Option configurations To add options to a product, order the correspondg item number. Description For E8362C For E8363C For E8364C For E8361C dditional formation Test set Option 014 Configurable test set E8362C-014 E8363C-014 E8364C-014 E8361C-014 Power configuration Option UNL Extended power range E8362C-UNL E8363C-UNL E8364C-UNL E8361C-UNL Only E8361C requires 014 and bias-tees Option 016 dd attenuators E8362C-016 E8363C-016 E8364C-016 E8361C-016 Requires UNL (only E8361C also requires 014) Option H85 1 High-power configuration E8362CH85 E8363CH85 E8364CH85 Includes 014, 016, UNL 2, 080, 081 Measurement applications Option 010 Time-doma capability E8362C-010 E8363C-010 E8364C-010 E8361C-010 Option 080 Frequency offset E8362C-080 E8363C-080 E8364C-080 E8361C-080 Requires 014 (E8361C only, 081 required if UNL is also purchased) Option 081 switch E8362C-081 E8363C-081 E8364C-081 E8361C-081 Requires 014, 080 (only E8361C also requires UNL) Option 082 Scalar-calibrated E8362C-082 E8363C-082 E8364C-082 E8361C-082 Requires 014, 080 converter measurements Option 083 Vector- and scalar-calibrated E8362C-083 E8363C-083 E8364C-083 E8361C-083 Requires 014, 080, 081(only E8361C converter measurements also requires UNL) Option Embedded LO measurements E8362C-084 E8363C-084 E8364C-084 E8361C-084 Requires 082 or 083 Option port measurement application E8362C-550 E8363C-550 E8364C-550 E8361C-550 Requires 014 Option N-port capabilities E8362C-551 E8363C-551 E8364C-551 E8361C-551 Requires 014 Pulse, antenna, mm-wave Option H08 Pulsed-RF measurement E8362C-H08 E8363C-H08 E8364C-H08 E8361C-H08 Requires 014, 080 (Option H11 capability recommended) Option H11 IF access (for antenna, E8362C-H11 E8363C-H11 E8364C-H11 E8361C-H11 Requires 014, UNL, 080, and 081 pulsed-rf and mm-wave measurements) ccessories Option 1CM Rack mount kit for use E8362C-1CM E8363C-1CM E8364C-1CM E8361C-1CM with handles Option 1CP Rack mount kit for use E8362C-1CP E8363C-1CP E8364C-1CP E8361C-1CP with handles Calibration documentation Option 17 ISO compliant E8362C-17 E8363C-17 E8364C-17 E8361C-17 calibration Option UK6 Commercial calibration E8362C-UK6 E8363C-UK6 E8364C-UK6 E8361C-UK6 certificate with test data Option 6J NSI Z540 compliant E8362C-6J E8363C-6J E8364C-6J E8361C-6J calibration Calibration software for self-mataers Option Perpetual license of built- E8362C-897 E8363C-897 E8364C-897 E8361C-897 performance test software for gilent exclusive calibration Option Perpetual license of built- E8362C-898 E8363C-898 E8364C-898 E8361C-898 performance test software for standards compliant calibration 1. Option H85 is ordered as a separate model, as dicated. 2. UNL up to 67 GHz does not clude bias-tees. Only cludes source attenuators. 3. Requires firmware and above, plus 1.1 GHz CPU board. 4. Option 550 is a subset of 551; therefore they cannot be ordered together. When orderg a test set, select an option to specify the appropriate terconnect jumper cable set between the analyzer and the test set. 5. dditional hardware required. Please refer to the analyzer s Service Guide for required service test equipment. 3
4 The microwave PN Series struments are tegrated vector network analyzers equipped with a built- S-parameter test set, synthesized source, a hard disk drive, USB terfaces, and an 8.4 LCD color touch screen display. The E8362C has 3.5 mm male 50-ohm test ports. The E8363C/64C have 2.4 mm male 50-ohm test ports. The E8361C has 1.85 mm male 50-ohm test ports. Included with each strument is a mouse, keyboard (U.S.) and a 1-year return-to-gilent service warranty. Test set and power configuration options Configurable test set (Option 014) Provides six front panel access loops. Three access loops are for port one and three for port two. The loops provide access to the signal path between (a) the source put and the reference, (b) the source put and directional coupler thru arm and (c) the coupled arm of the directional coupler and the port. This option provides the capability to improve strument sensitivity for measurg low-level signals, to reverse the directional coupler to achieve even more dynamic range or to add components and other peripheral struments for a variety of measurement applications. (see PN Series Microwave Data Sheet literature number EN for a basic block diagram) Extended power range and bias-tees (Option UNL) dds two 60 db step attenuators and two bias-tees to the E8362/3/4C. dds two 50 db step attenuators and two bias-tees to the E8361C. step attenuator and bias-tee set is serted between the source and test port one and another set between the source and test port two. (see PN Series Microwave Data Sheet literature number EN for a basic block diagram) dd attenuators (Option 016) n attenuator is added between each test port and its correspondg. Two 35 db step attenuators are added to the E8362/3/4C. Two 50 db step attenuators are added to the E8361C (see PN Series Microwave Data Sheet literature number EN for a basic block diagram). High-power test set (Model E836xCH85) This configuration combes options that are often necessary for high power measurements (UNL 1, 014, 016, 080, 081). The only difference between orderg Option H85 versus a combation of the options listed above is the source attenuator option UNL. Standard UNL cludes two source attenuators and two bias-tees. Option H85 cludes the two source attenuators, but not the bias-tees, as the bias-tees are the power-limitg factor the network analyzer test set. The maximum power at the test port is +43 (< 20 GHz), and +40 (> 20 GHz). Option 080, frequency-offset mode, is cluded Option H85 because it manages the phase-lockg ternally (stead of dependg on the R1 ). So if you need to use external components the path of the R1, it makes the measurements simpler and more robust. Measurement applications Time-doma capability (Option 010) For viewg reflection and transmission responses time or distance doma. Frequency offset (Option 080) This option enables the PN Series microwave network analyzers to set the source frequency dependently from where the s are tuned. This ability is important for two general classes of devices: mixers (and converters) and amplifiers. Option 080 provides a very basic user terface. switch (Option 081) Option 081 adds a solid-state ternal RF transfer switch the R1 reference- path (see PN Series Microwave Data Sheet literature number EN for a block diagram). The switch allows the strument to easily switch between standard S-parameter (non-frequency-offset) measurements and frequency offset measurements such as relative phase or absolute group delay that require an external reference mixer. The user can set the switch manually or remotely, but it is best used with the frequency-converter application (Option 083), where it is controlled automatically durg the vector-mixer calibration procedure and subsequent measurements. Scalar-calibrated converter measurements (Option 082) With a simple setup and calibration, this application provides the highest accuracy for conversion-loss (or ga) measurements by combg one-port and power-meter calibrations to remove mismatch errors. Option 080 required. Vector- and scalar-calibrated converter measurements (Option 083) This converter measurement adds an tuitive and easy-to-use user terface, advanced calibration choices that provide exceptional amplitude and phase accuracy, and control of external signal sources for use as local oscillators. Mixer calibration techniques clude scalar-mixer calibration and vector-mixer calibration (requires Option 081). Fally, the frequency-converter application supports all of gilent s major signal source families. Embedded LO Measurements (Option 084) This option tunes the PN s to the put frequency of the converter under test, with the need for access to ternal LOs or a common reference signal. For converters with embedded LOs, this option enables measurements of match-corrected conversion loss/ga (requires Option 082 or 083), and absolute group delay (requires Option 083). 1. UNL does not clude bias-tees. Only cludes source attenuators 4
5 4-port measurement application (Option 550) dds multiport analyzer mode to any PN network analyzer with Option 014 configurable test set, which enables full 4-port error correction and measurement capabilities usg an external test set. Only standard measurement class is available the multiport analyzer mode. N-port capabilities (Option 551) dds multiport analyzer mode to any PN network analyzer with Option 014 configurable test set, which enables full N-port error correction and measurement capabilities usg an external test set. Only standard measurement class is available the multiport analyzer mode. Pulse, antenna, mm-wave Pulsed-RF measurement capability (Option H08) Provides software to set up and control pulsed-rf measurements with pot--pulse capability. The software sets the coefficient of the PN s digital-if filter to null unwanted spectral components, enables the IF gates provided with IF access (Option H11), and controls selected gilent pulse generators. It can be run on the PN or an external computer..dll file contag the IF-filter algorithms is cluded for automated pulsed-rf testg. The pulsed application is configured to work with the gilent series pulse generator. For more detailed formation regardg pulsed measurement capabilities with the microwave PN refer to the gilent Web site and download the PN Series MW Network nalyzers Configuration Guide for Pulsed Measurements, literature number EN. IF access (Option H11) Provides hardware to enable antenna, pot- pulse, and broadband millimeter-wave measurements to 110 GHz. For each of the MW PN s measurement s, IF gates (enabled with pulsed measurement capability, Option H08) and external IF puts are added. In addition, access to the PN s ternal RF and LO source is provided for remote mixg applications. For basic antenna measurements, only Option H11 is necessary. Pulsed antenna applications also require the pulsed measurement capability (Option H08). Broadband measurements to 110 GHz, also requires an N5260 millimeter-wave test set controller. ccessories Rack mount kit with handles (Option 1CM) dds a rack mount ( ) and rail kit (E3663C) for use with handles. Rack mount kit with handles (Option 1CP) dds a rack mount ( ) 1 and rail kit (E3663C) for use with standard supplied handles. Configuration Details Selectg the correct mixer-test configuration: Most mixer or converter test applications require Options 014, 080, and 082 for conversion loss/ga, or Options 014, 080, 081 and 083 for conversion loss/ga and phase/delay measurements. If you want to create and automate your own custom frequencyoffset measurements (for example, termodulation distortion), you may only need Options 014 and 080. For converters that require put power below -27, or for devices that have a large amount of LO feedthrough (like an unfiltered mixer), Option UNL, which adds source attenuators, is highly recommended. Besides allowg lower put power levels, these attenuators improve the isolation between the PN s ternal source and LO leakage signals, helpg to prevent source-unleveled errors. For devices that put signals near or above the s compression levels (which varies between 3 and +5, dependg on the model and frequency), Option 016 is recommended, which adds attenuators. Fally, Option 010, which adds time-doma analysis, is very useful for gatg unwanted, time-delayed responses which often occur when measurg mixers. Note: Use external IF access for up to 20 db more sensitivity when makg antenna measurements with a remote mixg configuration. dd Option H08 (Pulsed-RF Measurement Capability) to enable advanced pulsed measurements. Or upgrade to a broadband (10 MHz to 110 GHz) VN system simply by purchasg an N5260 controller test set with test heads (Option 110, 120, or 130). 1. The kit assumes you have the standard handles shipped with the strument. If you do not have handles, order a kit. 5
6 Simplified test set block diagrams Standard power range Switch/splitter R1 R2 Measurement s B Port 1 Port 2 Extended power range and bias-tees (Option UNL) Switch R1 R2 attenuator1 attenuator1 Bias-tee Measurement s B Bias-tee Port 1 Port 2 1. attenuator for E8362/3/4C is 60 db 10 db steps. attenuator for E8361C is 50 db 10 db steps. 6
7 Simplified test set block diagrams contued Configurable test set (Option 014) Switch R1 R2 Measurement s B Port 1 Port 2 Configurable test set with extended power range and bias-tees (Option UNL and 014) Switch R1 attenuator1 R2 attenuator1 Bias-tee Measurement s B Bias-tee Port 1 Port 2 1. attenuator for E8362/3/4C is 60 db 10 db steps. attenuator for E8361C is 50 db 10 db steps. 7
8 Simplified test set block diagrams contued Fully optioned, active device or mixer/converter test configuration (Options 014, UNL, 016, 080, 081) Switch/splitter/leveler R1 R2 attenuator1 attenuator1 Option 081 Measurement 10 db steps s 10 db steps Bias-tee B Bias-tee Receiver attenuator2 Rcvr R1 SRC thru arm Rcvr Rcvr B arm thru SRC Rcvr R2 1. attenuator for E8362/3/4C is 60 db 10 db steps. attenuator for E8361C is 50 db 10 db steps. 2. Receiver attenuator for E8362/3/4C is 35 db 5 db steps. Receiver attenuator for E8361C is 50 db 10 db steps. 8
9 Simplified test set block diagrams contued High-power configuration (Model E836xCH85) Switch/splitter/leveler +15 R R2 Option 081 attenuator 1 attenuator Measurement 10 db steps s 10 db steps B Receiver attenuator Rcvr R1 SRC thru arm Rcvr Rcvr B arm thru SRC Rcvr R2 DUT preamp Power levels shown on the diagram are damage levels. t a mimum, keep power levels 6 db below damage level. For optimal performance, keep the power level cident upon the s -20 or less. This will keep the s of compression. 1. attenuator for E8362/3/4C is 60 db 10 db steps. 2. Receiver attenuator for E8362/3/4C is 35 db 5 db steps. 9
10 Simplified test set block diagrams contued Fully optioned, pulse-rf, antenna, or mm-wave configuration (Options 014, UNL, 016, 080, 081, H11) ux RF (2 to 20 GHz) ux LO (2 to 20 GHz) Rear 8.33 MHz reference Option 080 Phase-locked loop Offset Offset LO V tune YIG source Multipliers (1, 2) Multipliers (1, 2, 4) LO Option H11 Option 081 Option H11 1 IF gate Option H11 1 IF gate DC DC External IF R1 R2 External IF Option UNL Option UNL External IF External IF DC DC IF gate Option H11 1 B IF gate Option H11 1 Option UNL Option UNL Front Option 016 Receiver attenuators Option 014 Port 1 Option 014 Port 2 Option Option H11: IF-gate controls and external-if puts are accessed on rear panel. IF gates are enabled with Option H08. External-IF put frequency is 8.33 MHz. 10
11 Upgrade kits Upgrade kits for the PN Series E8361C, E8362C, E8363C, E8364C Upgrade kits are available to add options after itial purchase. To order an upgrade kit for the PN series, order the analyzer s model number followed by a U, then dicate the option to be added (for example, E8362CU-010). The current configuration and serial number of the strument to be retrofitted are required as part of the order. Time-doma (Option 010) User stallable. Configurable test set (Option 014) Provides six front-panel RF access loops. Includes stallation at an gilent service center. Receiver attenuators (Option 016) Includes stallation at an gilent service center. Frequency range upgrade to an E8363C (40 GHz) PN (Option 040/041) vailable only for the E8362C. Includes stallation at an gilent service center. Frequency range upgrade to an E8364C (50 GHz) PN (Option 050/051) vailable only for the E8362C and E8363C. Includes stallation at an gilent service center. Frequency range upgrade to an E8361C (67 GHz) PN (Option 067/068) vailable only for the E8363C and E8364C. Includes stallation at an gilent service center. Frequency-offset (Option 080) Includes stallation at an gilent service center. External reference switch (Option 081) Includes stallation at an gilent service center. Scalar-calibrated converter measurements (Option 082) User stallable. Option 080 required. Frequency converter measurement application (Option 083) User stallable. Option 080 and 081 required. Embedded LO Measurements (Option 084) dvanced software tung that provides absolute group delay of converters with embedded LOs with the need for access to a common reference signal. The measurement result is the same as lockg the DUT LO to the reference mixer LO. (Options 080 and 083 required) Requires firmware and above plus 1.1 GHz CPU board. /B to C model upgrades Order E8361U-221, E8362BU-221, E8363BU-221, or E8364BU-221 Note: 1.1 GHz CPU is required to upgrade. Please refer to Customer Support Service Guides for the correct part number 4-Port measurement application (Option 550) (vailable for E8361C, E8362C/3C/4C) Enables full 4-port error correction and differential measurements. Option 014 and external test set required. User stallable. N-port capabilities (Option 551) (vailable for E8361C, E8362C/3C/4C) dds full N-port error correction and measurement capabilities. Option 014 and external test set required. User stallable. Extended power range (Option UNL) dds a step attenuator and a bias-tee between source and each test port. Includes stallation at an gilent service center. Pulsed-RF measurement capability (Option H08) Provides software to set up and control pulsed-rf measurements usg narrowband detection, with pot--pulse and pulse-profile capability. User stallable. IF access (Option H11) Provides hardware for antenna, pot--pulse, and millimeterwave measurements. dds rear-panel RF and LO puts, external IF puts, and IF gates (gates enabled with Option H08). Includes stallation at an gilent service center. High-power test set (Option H85) Removes bias tees for higher test port power-handlg capability. Options UNL, 014, 016, 080, and 081 are required. Includes stallation at an gilent Service Center. Calibration Software Licenses Perpetual license for built- performance test software for gilent clusive cal (Option 897) dds built- performance testg and calibration software for self-mataers. Requires additional equipment. See the analyzer s Service Guide for more formation on equipment required. Perpetual license for built- performance test software for standards compliant cal (Option 898) dds built- performance testg and calibration software for self-mataers. Requires additional equipment. See the analyzer s Service Guide for more formation on equipment required. Note: For applications, measurement accessories, and general accessories please see gilent PN Family Network nalyzers Configuration Guide, part number EN. 11
12 gilent Updates Get the latest formation on the products and applications you select. LN extensions for Instruments puts the power of Ethernet and the Web side your test systems. gilent is a foundg member of the LXI consortium. gilent Channel Partners Get the best of both worlds: gilent s measurement expertise and product breadth, combed with channel partner convenience. Expand your measurement capabilities with gilent qualified channel partners Our channel partners offer accessories and measurement solutions that extend your network analysis capabilities. For more formation ab probg equipment and accessories, contact: Cascade Microtech, Inc 2430 NW 206th venue Beaverton, Oregon 97006, US Toll free telephone: Telephone: (503) Fax: (503) Web site: [email protected] gilent dvantage Services is committed to your success through your equipment s lifetime. To keep you competitive, we contually vest tools and processes that speed up calibration and repair and reduce your cost of ownership. You can also use Infole Web Services to manage equipment and services more effectively. By sharg our measurement and service expertise, we help you create the products that change our world. For more formation on gilent Technologies products, applications or services, please contact your local gilent office. The complete list is available at: mericas Canada (877) Brazil (11) Mexico United States (800) sia Pacific ustralia Cha Hong Kong India Japan 0120 (421) 345 Korea Malaysia Sgapore Taiwan Other P Countries (65) Europe & Middle East Belgium 32 (0) Denmark Fland 358 (0) France * *0.125 /mute Germany 49 (0) Ireland Israel /544 Italy Netherlands 31 (0) Spa 34 (91) Sweden United Kgdom 44 (0) For other unlisted countries: Revised: June 8, 2011 Product specifications and descriptions this document subject to change with notice. gilent Technologies, Inc Published US, July 26, EN Pentium is a U.S. registered trademark of Intel Corporation. Microsoft and Wdows are registered trademarks of Microsoft Corporation. 12
Agilent E5063A ENA Series Network Analyzer
Agilent E5063A ENA Series Network Analyzer 100 khz to 4.5/ 8.5/18 GHz Configuration Guide Ordering Guide The following steps will guide you through configuring your E5063A. Standard furnished item Description
Keysight M9485A PXIe Multiport Vector Network Analyzer. Configuration Guide
Keysight M9485A PXIe Multiport Vector Network Analyzer Configuration Guide 02 Keysight M9485A PXIe Multiport Vector Network Analyzer - Configuration Guide Ordering Guide The following steps will guide
Agilent 8753ET/8753ES Network Analyzers
Agilent 8753ET/8753ES Network Analyzers 8753ET, 300 khz to 3 or 6 GHz 8753ES, 30 khz to 3 or 6 GHz Configuration Guide System configuration summary The following summary lists the main components required
Agilent U2000 Series USB Power Sensors
Agilent U2000 Series USB Power Sensors Configuration Guide U2000 Series USB Power Sensors U2000A (10 MHz to 18 GHz) U2001A (10 MHz to 6 GHz) U2002A (50 MHz to 24 GHz) U2004A (9 khz to 6 GHz) U2000H (10
Agilent 8720 Family Microwave Vector Network Analyzers
Agilent 8720 Family Microwave Vector Network Analyzers Product Overview High-Performance Solutions for Your Measurement Challenges Now more choices for solving your measurement challenges What's new in
X-Series Signal Analysis. Future-ready instruments Consistent measurement framework Broadest set of applications and software
X-Series Signal Analysis Future-ready instruments Consistent measurement framework Broadest set of applications and software Arrive Ahead with X-Series We can t predict the future, but Agilent can help
E5092A Configurable Multiport Test Set
Keysight Technologies E5080A Network Analyzer 9 khz to 4.5/6.5/9 GHz E5092A Configurable Multiport Test Set Configuration Guide 02 Keysight 5080A Network Analyzer & E5092A Configurable Multiport Test Set
Agilent E5063A ENA Series Network Analyzer. 100 khz to 4.5/ 8.5/18 GHz
Agilent E5063A ENA Series Network Analyzer 100 khz to 4.5/ 8.5/18 GHz The Best Balance Between Price and Performance The E5063A is a low cost network analyzer for simple passive component testing up to
Basics of RF Amplifier Measurements with the E5072A ENA Series Network Analyzer
Basics of RF Amplifier Measurements with the E5072A ENA Series Network Analyzer Application Note Introduction The RF power amplifier is a key component used in a wide variety of industries such as wireless
What is the difference between an equivalent time sampling oscilloscope and a real-time oscilloscope?
What is the difference between an equivalent time sampling oscilloscope and a real-time oscilloscope? Application Note In the past, deciding between an equivalent time sampling oscilloscope and a real
U7248A High Speed Inter-Chip (HSIC) Electrical Test Software Infiniium Oscilloscopes
U7248A High Speed Inter-Chip (HSIC) Electrical Test Software Infiniium Oscilloscopes Data Sheet This application is available in the following license variations Order N7248A for user-installed license
Keysight Technologies N1918A Power Analysis Manager and U2000 Series USB Power Sensors. Demo Guide
Keysight Technologies N1918A Power Analysis Manager and U2000 Series USB Power Sensors Demo Guide Introduction This demonstration guide helps you to get familiar with the basic setup and coniguration requirements
Agilent E363xA Series Programmable DC Power Supplies. Data Sheet
Agilent E363xA Series Programmable DC Power Supplies Data Sheet Reliable Power, Repeatable Results Single and triple output 80 W to 200 W output power Dual range output Low noise and excellent regulation
Agilent Millimeter-Wave Network Analyzers 10 MHz to 110 GHz, with Extensions to 0.5 THz
Agilent Millimeter-Wave Network Analyzers 10 MHz to 110 GHz, with Extensions to 0.5 THz Technical Overview High Performance Bench-Top Network Analyzers Maximize your frequency coverage with a single sweep
How to Measure 5 ns Rise/Fall Time on an RF Pulsed Power Amplifier Using the 8990B Peak Power Analyzer
How to Measure 5 ns Rise/Fall Time on an RF Pulsed Power Amplifier Using the 8990B Peak Power Analyzer Application Note Introduction In a pulsed radar system, one of the key transmitter-side components
Agilent U2000 Series USB Power Sensors
Agilent U2000 Series USB Power Sensors Single/Multi-Channel Power Measurement Simple Setup Affordable Demo Guide Table of Contents Introduction 2 The Agilent N1918A Power 3 Analysis Manager Demonstration
The Next Generation in Automated Oscilloscope Test
The Next Generation in Automated Oscilloscope Test Spanning 100 MHz to 13 GHz, and varying in height from 1U to 8U, Agilent s family of LXI compliant oscilloscopes can accommodate virtually any automated
802.11ac Power Measurement and Timing Analysis
802.11ac Power Measurement and Timing Analysis Using the 8990B Peak Power Analyzer Application Note Introduction There are a number of challenges to anticipate when testing WLAN 802.11ac [1] power amplifier
Agilent MATLAB Data Analysis Software Packages for Agilent Oscilloscopes
Agilent MATLAB Data Analysis Software Packages for Agilent Oscilloscopes Data Sheet Enhance your InfiniiVision or Infiniium oscilloscope with the analysis power of MATLAB software Develop custom analysis
Agilent 8762/3/4A,B,C Coaxial Switches
Agilent 8762/3/4A,B,C Coaxial Switches Technical Overview High performance switches for microwave and RF instrumentation and systems Agilent Technologies offers a ver satile line of multiport coaxial switches.
Agilent Infoline Web Services. Quick Reference Guide. Scan and use your phone to go to Infoline at www.agilent.com/find/service
Agilent Infoline Web Services Quick Reference Guide Scan and use your phone to go to Infoline at www.agilent.com/find/service One location for all information This quick reference guide reviews the powerful
Agilent Test Solutions for Multiport and Balanced Devices
Agilent Test Solutions for Multiport and Balanced Devices Duplexer test solutions 8753ES option H39/006 During design and final alignment of duplexers, it is often necessary to see both the transmit-antenna
Agilent U2000 Series USB Power Sensors
Agilent U2000 Series USB Power Sensors GSM Timeslot Burst Power Measurement Product Note Table of Content Introduction 2 Measuring GSM Timeslot 4 Signal Overview of Agilent U2000 5 Series USB Power Sensors
High Power Amplifier Measurements Using Agilent s Nonlinear Vector Network Analyzer
High Power Amplifier Measurements Using Agilent s Nonlinear Vector Network Analyzer Application Note 1408-19 Table of Contents Introduction...2 PNA-X Performance...3 Hardware Setup...6 Setup Examples...12
Agilent Compatibility of the U2000 Series USB Power Sensors with Agilent Instruments. Application Note
Agilent Compatibility of the U2000 Series USB Power Sensors with Agilent Instruments Application Note Table of Contents Introduction 2 U2000 Series USB Power 3 Sensor s Compatibility with Agilent Instruments
Agilent Electronic Calibration (ECal) Modules for Vector Network Analyzers
Agilent Electronic Calibration (ECal) Modules for Vector Network Analyzers N4690 Series, 2-port Microwave ECal 85090 Series, 2-port RF ECal N4430 Series, 4-port ECal Technical Overview Control ECal directly
Agilent N2717A Service Software Performance Verification and Adjustment Software for the Agilent ESA Spectrum Analyzers Product Overview
Agilent N2717A Service Software Performance Verification and Adjustment Software for the Agilent ESA Spectrum Analyzers Product Overview Reduce your cost of ownership by minimizing time to calibrate and
Agilent E5061B Network Analyzer. 100 khz to 1.5 GHz/3 GHz 5 Hz to 3 GHz
Agilent E5061B Network Analyzer 100 khz to 1.5 GHz/3 GHz 5 Hz to 3 GHz E5061B responds to various measurement needs, from LF to RF The Agilent E5061B is a member of the industry standard ENA Series network
Agilent PNA Network Analyzers 10 MHz to 110 GHz
Agilent PNA Network Analyzers 10 MHz to 110 GHz Meeting your measurement needs today and into the future... Exceptional performance Advanced automation Flexible connectivity Easy-to-use PNA Network Analyzers
Agilent FieldFox Remote Viewer
Agilent FieldFox Remote Viewer Application Brief Agilent Remote Viewer setup instructions The FieldFox remove viewer is a FREE ios application which allows you to view an Agilent FieldFox analyzer from
Agilent 87421A/87422A Power Supply
Agilent 87421A/87422A Power Supply Technical Overview Designed specifically for Agilent Technologies microwave system amplifiers Bias cable permits remote placement Compact size for easy system integration
Keysight N6854A Geolocation System. Configuration Guide
Keysight N6854A Geolocation System Configuration Guide 02 Keysight N6854A Geolocation System - Configuration Guide This guide will help you configure a geolocation system that meets your needs and includes
Evaluating Oscilloscope Bandwidths for Your Application
Evaluating Oscilloscope Bandwidths for Your Application Application Note Table of Contents Introduction....1 Defining Oscilloscope Bandwidth.....2 Required Bandwidth for Digital Applications...4 Digital
Agilent N5970A Interactive Functional Test Software: Installation and Getting Started
Agilent N5970A Interactive Functional Test Software: Installation and Getting Started Application Note The N5970A Interactive Functional Test Software along with the 8960 Series 10 (E5515C) wireless communications
Make Better RMS Measurements with Your DMM
Make Better RMS Measurements with Your DMM Application Note Introduction If you use a digital multimeter (DMM) for AC voltage measurements, it is important to know if your meter is giving you peak value,
N6171A MATLAB Data Analysis Software for Agilent Instruments
N6171A MATLAB Data Analysis Software for Agilent Instruments Technical Overview MATLAB is available directly from Agilent or its authorized sales partners with your instrument purchase Use MATLAB to create
Agilent 4339B/4349B High Resistance Meters
Agilent 4339B/4349B High Resistance Meters Technical Overview Within Budget Without Compromise Introducing the Agilent Technologies 4339B and 4349B High Resistance Meters Used for Making Ultra- High Resistance
Agilent P940xA/C Solid State PIN Diode Switches
Agilent P940xA/C Solid State PIN Diode Switches Operating and Service Manual Agilent Technologies Notices Agilent Technologies, Inc. 2007 No part of this manual may be reproduced in any form or by any
Keysight Technologies Using Fine Resolution to Improve Thermal Images. Application Note
Keysight Technologies Using Fine Resolution to Improve Thermal Images Application Note Introduction Digital imaging opened up new possibilities and has been very much part of our lives since social media
Performing Amplifier Measurements with the Vector Network Analyzer ZVB
Product: Vector Network Analyzer R&S ZVB Performing Amplifier Measurements with the Vector Network Analyzer ZVB Application Note This document describes typical measurements that are required to be made
Keysight E5063A ENA Series PCB Analyzer
Keysight E5063A ENA Series PCB Analyzer Technical Overview The Best Solution for PCB Manufacturing Test More accuracy and R&R More languages supported More ESD robustness Why choose the E5063A PCB Analyzer
N5416A and N5417A USB Compliance Test Software for Infiniium Oscilloscopes
N546A and N547A USB Compliance Test Software for Infiniium Oscilloscopes Data Sheet The N546A USB compliance test software for Infiniium oscilloscopes gives you a fast and reliable way to verify USB electrical
PXI and AXIe Modular Instrumentation
PXI and AXIe Modular Instrumentation M9018A PXIe Chassis M9502A AXIe Chassis M9505A AXIe Chassis U4002A Digital Test Console Chassis Tested Computer List Technical Note DISCOVER the Alternatives......
Agilent Compatibility of USB Power Sensors with Agilent Instruments. Application Note
Agilent Compatibility of USB Power Sensors with Agilent Instruments Application Note Use USB Power Sensors as an Agilent Instruments Accessory Table of Contents Agilent USB Power Sensors 2 USB Power Sensor
DDR Memory Overview, Development Cycle, and Challenges
DDR Memory Overview, Development Cycle, and Challenges Tutorial DDR Overview Memory is everywhere not just in servers, workstations and desktops, but also embedded in consumer electronics, automobiles
R&S ZVA-Z75, -Z110, -Z140, -Z170, -Z220, -Z325, -Z500 Converters Quick Start Guide
R&S ZVA-Z75, -Z110, -Z140, -Z170, -Z220, -Z325, -Z500 Converters Quick Start Guide (=7ÔWÌ) 1307.7039.62 06 Test & Measurement Quick Start Guide This Quick Start Guide describes the following converter
Agilent 4338B Milliohm Meter
Agilent 4338B Milliohm Meter 10 µω to 100 kω Technical Overview Introduction Ideal for precise measurements of extremely low resistances using an ac test signal, the Agilent Technologies 4338B suits bench-top
Agilent E6832A W-CDMA Calibration Application
Agilent E6832A W-CDMA Calibration Application For the E6601A Wireless Communications Test Set Data Sheet The next generation of mobile phone manufacturing test. E6601A is the newest test set from Agilent
Testing WiMAX receiver performance in a multipath propagation environment using Agilent s E6651A with an EB Propsim C8 radio channel emulator
Testing WiMAX receiver performance in a multipath propagation environment using Agilent s E6651A with an EB Propsim C8 radio channel emulator Application Note 1 Summary Introduction As a part of the certification
Time-Correlated Multi-domain RF Analysis with the MSO70000 Series Oscilloscope and SignalVu Software
Time-Correlated Multi-domain RF Analysis with the MSO70000 Series Oscilloscope and SignalVu Software Technical Brief Introduction The MSO70000 Series Mixed Oscilloscope, when coupled with SignalVu Spectrum
Agilent BenchVue Software (34840B) Data capture simplified. Click, capture, done. Data Sheet
Agilent BenchVue Software (34840B) Data capture simplified. Click, capture, done. Data Sheet Use BenchVue software to: Visualize multiple measurements simultaneously Easily capture data, screen shots and
Agilent Mobile WiMAX R&D Test Set Solutions: Software and Technical Support Contract
Agilent Mobile WiMAX R&D Test Set Solutions: Software and Technical Support Contract Product Overview Maximize the potential of the E6651A Mobile WiMAX test set and related software with the latest software
Impedance 50 (75 connectors via adapters)
VECTOR NETWORK ANALYZER PLANAR TR1300/1 DATA SHEET Frequency range: 300 khz to 1.3 GHz Measured parameters: S11, S21 Dynamic range of transmission measurement magnitude: 130 db Measurement time per point:
Keysight Technologies Connecting Data Acquisition Systems to a Wireless Network
Keysight Technologies Connecting Data Acquisition Systems to a Wireless Network Application Brief Test Challenges: Designing heating and air conditioning (HVAC) systems Collecting data on a remotely located
Agilent 8510-13 Measuring Noninsertable Devices
Agilent 8510-13 Measuring Noninsertable Devices Product Note A new technique for measuring components using the 8510C Network Analyzer Introduction The majority of devices used in real-world microwave
PXI and AXIe Modular Instrumentation
PXI and AXIe Modular Instrumentation M9018A PXIe Chassis M9502A AXIe Chassis M9505A AXIe Chassis Tested Computer List Technical Note DISCOVER the Alternatives...... Agilent MODULAR Products OVERVIEW This
TekConnect Adapters. TCA75 TCA-BNC TCA-SMA TCA-N TCA-292MM Data Sheet. Applications. Features & Benefits
TekConnect Adapters TCA75 TCA-BNC TCA-SMA TCA-N TCA-292MM Data Sheet TCA-N TekConnect-to-N DC to 11 GHz (Instrument Dependent) 50 Ω Input (Only) TCA-SMA TekConnect-to-SMA DC to 18 GHz (Instrument Dependent)
Technical Datasheet Scalar Network Analyzer Model 8003-10 MHz to 40 GHz
Technical Datasheet Scalar Network Analyzer Model 8003-10 MHz to 40 GHz The Giga-tronics Model 8003 Precision Scalar Network Analyzer combines a 90 db wide dynamic range with the accuracy and linearity
Agilent De-embedding and Embedding S-Parameter Networks Using a Vector Network Analyzer. Application Note 1364-1
Agilent De-embedding and Embedding S-Parameter Networks Using a Vector Network Analyzer Application Note 1364-1 Introduction Traditionally RF and microwave components have been designed in packages with
Power Amplifier Gain Compression Measurements
Technical Brief Power Amplifier Gain Compression Measurements GPIB Private Bus Sweep Out Sweep In Pulse In AC Mod Out Blank/Marker Out Blanking In Overview The 1 db gain compression of an amplifier describes
HP 8753E RF Vector Network Analyzer
HP 8753E RF Vector Network Analyzer 30 khz to 3 or 6 GHz Fast and powerful, the HP 8753E is perfectly adapted for superior, efficient measurements 2 Impressive 300% speed improvement in measurement sweep,
Real-Time Spectrum Analysis for Troubleshooting 802.11n/ac WLAN Devices
Real-Time Spectrum Analysis for Troubleshooting 802.11n/ac WLAN Devices Application Brief 802.11 WLAN devices operate in the license-exempt 2.4 GHz ISM and 5 GHz UNII bands, where they must share spectrum
Agilent 10 Hints for Making Better Network Analyzer Measurements. Application Note 1291-1B
Agilent 10 Hints for Making Better Network Analyzer Measurements Application Note 1291-1B Contents HINT 1. Measuring high-power amplifiers HINT 2. Compensating for time delay in cable HINT 3. Improving
RF Network Analyzer Basics
RF Network Analyzer Basics A tutorial, information and overview about the basics of the RF Network Analyzer. What is a Network Analyzer and how to use them, to include the Scalar Network Analyzer (SNA),
Variable Frequency Drive Troubleshooting with U1610A/U1620A
Variable Frequency Drive Troubleshooting with U1610A/U1620A Application Note Electric motors form the backbone of most industrial and manufacturing environments. Variable frequency drives (VFDs) (also
Keysight Technologies Long-Term, Remote Monitoring of Satellite Performance
Keysight Technologies Long-Term, Remote Monitoring of Satellite Performance Using a Keysight High-Frequency USB Power Sensor Application Note 1.0 Introduction Satellite communication systems are driven
HP 8970B Option 020. Service Manual Supplement
HP 8970B Option 020 Service Manual Supplement Service Manual Supplement HP 8970B Option 020 HP Part no. 08970-90115 Edition 1 May 1998 UNIX is a registered trademark of AT&T in the USA and other countries.
Keysight Technologies 8 Hints for Better Spectrum Analysis. Application Note
Keysight Technologies 8 Hints for Better Spectrum Analysis Application Note The Spectrum Analyzer The spectrum analyzer, like an oscilloscope, is a basic tool used for observing signals. Where the oscilloscope
Agilent Technologies. Troubleshooting Three-Phase AC Motors with U1210 Series Handheld Clamp Meters. Application Note
Agilent Technologies Troubleshooting Three-Phase AC Motors with U1210 Series Handheld Clamp Meters Application Note INTRODUCTION In today s world, the three-phase AC induction motors are widely used in
Agilent PN 89400-13 Extending Vector Signal Analysis to 26.5 GHz with 20 MHz Information Bandwidth
Agilent PN 89400-13 Extending Vector Signal Analysis to 26.5 GHz with 20 MHz Information Bandwidth Product Note The Agilent Technologies 89400 series vector signal analyzers provide unmatched signal analysis
Revision 1.10 April 7, 2015 Method of Implementation (MOI) for 100BASE-TX Ethernet Cable Tests Using Keysight E5071C ENA Option TDR
Revision 1.10 April 7, 2015 Method of Implementation (MOI) for 100BASE-TX Ethernet Cable Tests Using Keysight E5071C ENA Option TDR 1 Table of Contents 1. Revision History... 3 2. Purpose... 3 3. References...
High-Speed Inter Connect (HSIC) Solution
High-Speed Inter Connect (HSIC) Solution HSIC Essentials Datasheet Protocol Decode Protocol decode Saves test time and resource costs. Designed for use with the MSO/DPO5000, DPO7000C, DPO/DSA/MSO70000C,
Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet
Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers Data Sheet Specifications Specifications are only valid for the stated operating frequency, and apply over 0 C to +55 C unless otherwise
DSA800 Series Spectrum Analyzer
DSA800 Series Spectrum Analyzer Configuration Guide This guide is used to help users to configure DSA800 series spectrum analyzer according to their requirements. You can get an overall understanding of
PCI Express 1.0 (2.5 GT/s) Protocol Test
PCI Express 1.0 (2.5 GT/s) Protocol Test Configuration and Pricing Guide Gen1 today, ready for Gen2 in the future As PCI Express Gen2 becomes more mature in the market, you must decide whether to continue
Agilent PN 8753-1 RF Component Measurements: Amplifier Measurements Using the Agilent 8753 Network Analyzer. Product Note
Agilent PN 8753-1 RF Component Measurements: Amplifier Measurements Using the Agilent 8753 Network Analyzer Product Note 2 3 4 4 4 4 6 7 8 8 10 10 11 12 12 12 13 15 15 Introduction Table of contents Introduction
High-voltage Differential Probes TMDP0200 - THDP0200 - THDP0100 - P5200A - P5202A - P5205A - P5210A
High-voltage Differential Probes TMDP0200 - THDP0200 - THDP0100 - P5200A - P5202A - P5205A - P5210A BNC interface (P5200A probes) TekVPI interface (TMDP and THDP Series probes) TekProbe interface (P5202A,
1.5 GHz Active Probe TAP1500 Datasheet
1.5 GHz Active Probe TAP1500 Datasheet Easy to use Connects directly to oscilloscopes with the TekVPI probe interface Provides automatic units scaling and readout on the oscilloscope display Easy access
MEASUREMENT UNCERTAINTY IN VECTOR NETWORK ANALYZER
MEASUREMENT UNCERTAINTY IN VECTOR NETWORK ANALYZER W. Li, J. Vandewege Department of Information Technology (INTEC) University of Gent, St.Pietersnieuwstaat 41, B-9000, Gent, Belgium Abstract: Precision
Jeff Thomas Tom Holmes Terri Hightower. Learn RF Spectrum Analysis Basics
Jeff Thomas Tom Holmes Terri Hightower Learn RF Spectrum Analysis Basics Agenda Overview: Spectrum analysis and its measurements Theory of Operation: Spectrum analyzer hardware Frequency Specifications
M24LRxx/CR95HF application software installation guide
User manual M24LRxx/CR95HF application software installation guide Introduction This user manual describes the procedures to install the different software drivers required to use the DEVKIT-M24LR-A development
Improving Network Analyzer Measurements of Frequency-translating Devices Application Note 1287-7
Improving Network Analyzer Measurements of Frequency-translating Devices Application Note 1287-7 - + - + - + - + Table of Contents Page Introduction......................................................................
E5061B-3L5 LF-RF Network Analyzer with Option 005 Impedance Analysis Function. Data Sheet
E506B-3L5 LF-RF Network Analyzer with Option 005 Impedance Analysis Function Data Sheet E506B-3L5 with Option 005; NA plus ZA in one box To ensure the performance and reliability of electronic equipment,
RF and Microwave Accessories. CD-ROM Catalog. Find the right component for your Rohde & Schwarz test & measurement equipment
RF and Microwave Accessories CD-ROM Catalog Find the right component for your Rohde & Schwarz test & measurement equipment Product group Typical applications Adapters Interchanging of various connector
81110A Pulse Pattern Generator Simulating Distorted Signals for Tolerance Testing
81110A Pulse Pattern Generator Simulating Distorted Signals for Tolerance Testing Application Note Introduction Industry sectors including computer and components, aerospace defense and education all require
Technical Overview with Self-Guided Demonstration
Agilent PSA Series Spectrum Analyzers External Source Control Measurement Personality, Option 215 Technical Overview with Self-Guided Demonstration Expand your PSA Series from spectrum analysis to scaler
Understanding Mixers Terms Defined, and Measuring Performance
Understanding Mixers Terms Defined, and Measuring Performance Mixer Terms Defined Statistical Processing Applied to Mixers Today's stringent demands for precise electronic systems place a heavy burden
Agilent Television Power Consumption Testing. Application Note
Agilent Television Power Consumption Testing Application Note Introduction Today, there are many types of televisions (TVs) on the market: the cathode ray tube (CRT) TV, liquid crystal display (LCD) TV,
iva Cable & Antenna Analyzer
iva Cable & Antenna Analyzer VSWR, Return Loss Measurement & Distance to Fault The iva Series Cable & Antenna Analyzer is an exciting new product from Kaelus that enables users to accurately measure VSWR/return
2. The Vector Network Analyzer
ECE 584 Laboratory Experiments 2. The Vector Network Analyzer Introduction: In this experiment we will learn to use a Vector Network Analyzer to measure the magnitude and phase of reflection and transmission
Agilent AN 1315 Optimizing RF and Microwave Spectrum Analyzer Dynamic Range. Application Note
Agilent AN 1315 Optimizing RF and Microwave Spectrum Analyzer Dynamic Range Application Note Table of Contents 3 3 3 4 4 4 5 6 7 7 7 7 9 10 10 11 11 12 12 13 13 14 15 1. Introduction What is dynamic range?
Jeff Thomas Tom Holmes Terri Hightower. Learn RF Spectrum Analysis Basics
Jeff Thomas Tom Holmes Terri Hightower Learn RF Spectrum Analysis Basics Learning Objectives Name the major measurement strengths of a swept-tuned spectrum analyzer Explain the importance of frequency
Michael Hiebel. Fundamentals of Vector Network Analysis
Michael Hiebel Fundamentals of Vector Network Analysis TABIH OF CONTENTS Table of contents 1 Introduction 12 1.1 What is a network analyzer? 12 1.2 Wave quantities and S-parameters 13 1.3 Why vector network
Agilent Automotive Power Window Regulator Testing. Application Note
Agilent Automotive Power Window Regulator Testing Application Note Abstract Automotive power window regulator tests require the use of accurate data acquisition devices, as they cover a wide range of parameters
R&S ZVA Vector Network Analyzer Specifications
www.atecorp.com 8-44-ATEC (2832) R&S ZVA Vector Network Analyzer Specifications ZVA_dat-sw_en_523-568-22_v_cover.indd Data Sheet. E stablished 98 Advanced Test Equipment Rentals Test & Measurement 4.5.22
LT-82 Stationary IR Transmitter
LT-82 Stationary IR Transmitter Configuration LT-82-0 (North America) LT-82-02 (Asia, UK) LT-82-03 (Euro) The Listen LT-82 is the heart of a stationary IR listening system. It takes the desired audio signal
R3765/67 CG Network Analyzer
R3765/67 CG Network Analyzer RSE 05.03.02 1 R376XG Series Overview R3765 300kHz ~ 3.8 GHz R3767 300kHz ~ 8 GHz AG BG Basic model Built-in Bridge A/R & B/R Transmission Reflection CG Built-in S-parameter
Agilent EEsof EDA. www.agilent.com/find/eesof
Agilent EEsof EDA This document is owned by Agilent Technologies, but is no longer kept current and may contain obsolete or inaccurate references. We regret any inconenience this may cause. For the latest
Updating the QIAcube operating software
Updating the QIAcube operating software This document describes how to upgrade your QIAcube mainboard firmware to version P, your mainboard PLC program to version R, and your centrifuge firmware to version
Experiment 7: Familiarization with the Network Analyzer
Experiment 7: Familiarization with the Network Analyzer Measurements to characterize networks at high frequencies (RF and microwave frequencies) are usually done in terms of scattering parameters (S parameters).
