Agilent U2000 Series USB Power Sensors

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "Agilent U2000 Series USB Power Sensors"

Transcription

1 Agilent U2000 Series USB Power Sensors Single/Multi-Channel Power Measurement Simple Setup Affordable Demo Guide

2 Table of Contents Introduction 2 The Agilent N1918A Power 3 Analysis Manager Demonstration Preparation 3 Demo 1: Extended Distance 4 Multi-Channel Power Measurement using Agilent E5813A Networked 5-Port USB Hub The Agilent E5813A Networked 5-Port USB Hub Connecting the U2000 Series USB Power Sensors and the E5813A Networked 5-Port USB Hub Conclusion 8 Related Literature Optimized Single/Multi-Channel and Extended Distance Power Measurement In many power measurement applications today, users require multiple power measurements to be taken simultaneously. To add to the predicament, these measurements may have to be obtained from places where access is inconvenient. These obstacles can be overcome by using Agilent U2000 Series USB power sensors in combination with networked hubs or USB extenders. This not only expands the number of available USB ports so that more power measurements can be taken simultaneously, but also lengthens the distance between the measurement point(s) and the host computer. This demo guide shows the setup for the multi-channel power measurement with the USB power sensors via the Agilent E5813A networked 5-port USB hub. Introduction Traditional power-measurement methodologies require you to connect a power sensor to a power meter. As a result, the setup for multi-channel power measurement in manufacturing test systems will demand plenty of space on the test rack in order to accommodate both the power meter and the power sensors. This increases the costs of a test system significantly. The Agilent U2000 Series USB power sensor is a combination of a power meter and a power sensor that allows you to convert RF and microwave power into digital data directly and analyze this data using a Windows -based software application Agilent N1918A Power Analysis Manager. The powermeasurement readings can be retrieved using standard SCPI commands or IVI-COM/IVI-C drivers. The SCPI-based command set provides a user-friendly programming environment which allows you to communicate with the power sensor in the same way as you communicate with the power meter. For more information about the USB power sensors, refer to Agilent U2000 Series USB Power Sensors Technical Overview and Agilent U2000 Series USB Power Sensors Datasheet. Figure 1. Agilent U2000 Series USB power sensors 2

3 The Agilent N1918A Power Analysis Manager Agilent N1918A Power Analysis Manager is Windows-based application software that allows you to perform power analysis. This application interfaces with various front-end hardware devices to obtain time records and perform pulse analysis. N1918A is available in two versions. The basic version, the Agilent Power Panel, offers a standard graphical user interface (GUI) for basic power measurement as well as multichannel power measurement. The advanced version, the Agilent Power Analyzer, is available as an additional software license that allows you to perform advanced pulse analysis, multi-channel power measurements, and statistical analysis as well as measurement-reading recording. Figure 2. The Agilent Power Panel GUI This demo guide describes power measurements using the basic version, Power Panel. You must install the Power Panel before performing the power measurements. For more information on power measurements using Agilent N1918A, refer to Agilent N1918A Power Analysis Manager Technical Overview. For installation procedures, refer to Agilent N1918A Power Analysis Manager Installation Guide. To download the latest N1918A Power Analysis Manager software, please go to: Figure 3. The Agilent Power Analyzer GUI Demonstration Preparation The instruments and software listed in the table to the right are required to perform the demonstrations. You can download the latest version of software and instrument firmware at: Product Type Agilent U2000 Series USB power sensors Agilent E5813A network 5-port USB Hub Agilent USB 2.0 compliant cable, Mini-B connector with locking mechanism Agilent E5813A PC utility driver Agilent N1918A Power Analysis Manager Agilent IO Libraries Suite Model Number/Version Refer to Agilent U2000 Series USB Power Sensor Data Sheet E5813A U2031A/U2031B/U2031C Power Panel (R02.02.xx or later) IO Libraries Suite 15.1 or later 3

4 Demonstration Extended Distance Multi-Channel Power Measurement with Agilent E5813A Networked 5-Port USB Hub Objectives To show the ability of Agilent U2000 Series USB power sensors connected to Agilent E5813A to perform multichannel power measurement To overcome the limitation of USB cable length (five meters according to the USB industry specification) and extend the connection range using Agilent E5813A To demonstrate the capability of Agilent N1918A Power Analysis Manager, Power Panel version to perform multi-channel power measurement Using a LAN to communicate with your USB-interface test instruments allows you to control and program the instruments remotely without connectiondistance limitation. The Agilent E5813A networked 5-port USB hub provides these advantages and also allows multi-channel power measurement to be taken simultaneously when multiple USB power sensors are connected to the networked hub. The following sections show you how to extend the connection distance using the Agilent E5813A networked 5-port hub via a LAN cable for multi-channel power measurement with the Agilent U2000 Series USB power sensors. The Agilent E5813A Networked 5-Port USB Hub The E5813A networked 5-Port USB hub uses USB over an IP connection (LAN) to overcome the distance limitation. The USB power sensor can be remotely controlled from a PC or laptop via LAN. The E5813A can connect up to five units of the USB power sensors. In order for the USB power sensors to be detected by the E5813A, you must to install E5813A configuration utility. You can download the configuration utility program at: If you are unable to configure the E5813A, refer to the E5813A Installation Guide for detailed description. Figure 4. The Agilent E5813A networked 5-port USB hub Connecting the U2000 Series USB Power Sensors and the E5813A Networked 5-Port USB Hub Procedures 1. Connect your PC/laptop (installed with the N1918A Power Analysis Manager Power Panel version, Agilent E5813A PC utility driver, and Agilent IO Libraries Suite) to the E5813A via LAN. 2. Connect the USB power sensors and the E5813A via USB cable as shown in Figure 5. Perform the steps described on the next page to interconnect the E5813A and the USB power sensors. 4

5 AC outlet E5813A networked 5-port USB hub PC/laptop U2000 Series USB power sensors LAN cable USB Mini-B connector with locking mechanism Figure 5. USB power sensors and E5813A configuration diagram Instructions Keystrokes To establish connection between E5813A and PC/laptop via LAN: 1. Run the E5813A configuration utility. Double-click on the E5813A Configuration Utility shortcut on the desktop or access the program via Windows start menu. 2. Configure the E5813A (See Figure 6). Double-click on the E5813A or select the device and click Configure to set the IP address, subnet mask, and default gateway. 3. Configure the IP address and subnet mask (See Figure 7). 4. Configure the gateway and add the E5813A into connection list. Enter a device name that easily identifies the E5813A. Enter the IP address and subnet mask. Enter the gateway for your network. Tick the checkbox of Add to connection list to add the E5813A into connection list. 5. Reboot the E5813A. For the changes to take effect, click Update to reboot the device. Figure 6. E5813A configuration utility display Figure 7. Configuring IP address, subnet mask, and default gateway in the E5813A configuration utility 5

6 Connecting the U2000 Series USB Power Sensors and the E5813A Networked 5-Port USB Hub (Continued) Instructions Keystrokes To establish USB connectivity with Agilent IO Libraries Suite: Run the Agilent IO Libraries Suite (See Figure 8). Double click on the Agilent IO Libraries Suite shortcut on the desktop or access the program via Windows start menu. Figure 8. U2000 Series USB power sensors connectivity support auto-detected by Agilent IO Libraries Suite 6

7 Performing Multi-Channel Power Measurement Follow the instructions shown below to perform multi-channel power measurement using the N1918A Power Analysis Manager, Power Panel software. Instructions 1. Run the N1918A Power Analysis Manager, Power Panel software. Keystrokes Double-click the Power Panel shortcut on the desktop or access the program via the Windows start menu. 2. Create a multilist display view. 3. Capture power measurement using the multilist display. Click from the main toolbars. On the multilist display, right-click to open a content menu. Select Assignment Measurement to assign a measurement to the multilist display. Select your preferred measurement and click Assign to proceed. 4. Assign more measurements. Repeat step 3 by selecting other measurements. 5. Run all measurements at one time Click. (see Figure 9). 6. Stop all measurements at one time. Click. Figure 9. Multi-channel power measurement via Agilent N1918A Power Analysis Manager, Power Panel software 7

8 Conclusion The most aggravating limitation of USB is the length restriction. USB has an accepted maximum length of only five meters, according to the USB industry specification. In order to go beyond the limit of five meters, you need to use a USB networked hub. Agilent E5813A networked 5-Port USB hub is capable of extending the connection of the Agilent U2000 Series USB power sensors when you perform multi-channel power measurement via Agilent N1918A Power Analysis Manager, Power Panel software. Related Literature Agilent U2000 Series USB Power Sensor, Data Sheet, Literature Number EN Agilent U2000 Series USB Power Sensor, Technical Overview, Literature Number EN Agilent N1918A Power Analysis Manager, Technical Overview, Literature Number EN Agilent N1918A Power Analysis Manager, Installation Guide, Literature Number N Agilent Networked 5-Port USB Hub, E5813A Installation Guide, Literature Number E For the most up-to-date and complete application and product information, visit our product website at: 8

9 Agilent Updates Get the latest information on the products and applications you select. Agilent Direct LXI is the LAN-based successor to GPIB, providing faster, more efficient connectivity. Agilent is a founding member of the LXI consortium. Agilent Channel Partners Get the best of both worlds: Agilent s measurement expertise and product breadth, combined with channel partner convenience. Microsoft is a U.S. registered trademark of Microsoft Corporation. Remove all doubt Our repair and calibration services will get your equipment back to you, performing like new, when promised. You will get full value out of your Agilent equipment through-out its lifetime. Your equipment will be serviced by Agilent-trained technicians using the latest factory calibration procedures, automated repair diagnostics and genuine parts. You will always have the utmost confidence in your measurements. For information regarding self maintenance of this product, please contact your Agilent office. Agilent offers a wide range of additional expert test and measurement services for your equipment, including initial start-up assistance, onsite education and training, as well as design, system integration, and project management. For more information on repair and calibration services, go to: For more information on Agilent Technologies products, applications or services, please contact your local Agilent office. The complete list is available at: Americas Canada (877) Latin America United States (800) Asia Pacific Australia China Hong Kong India Japan 0120 (421) 345 Korea Malaysia Singapore Taiwan Thailand Europe & Middle East Austria 43 (0) Belgium 32 (0) Denmark Finland 358 (0) France * *0.125 /minute Germany 49 (0) Ireland Israel /544 Italy Netherlands 31 (0) Spain 34 (91) Sweden Switzerland United Kingdom 44 (0) Other European Countries: Revised: October 1, 2009 Product specifications and descriptions in this document subject to change without notice. Agilent Technologies, Inc. 2009, 2010 Printed in USA, May 26, EN

Agilent U2000 Series USB Power Sensors

Agilent U2000 Series USB Power Sensors Agilent U2000 Series USB Power Sensors Configuration Guide U2000 Series USB Power Sensors U2000A (10 MHz to 18 GHz) U2001A (10 MHz to 6 GHz) U2002A (50 MHz to 24 GHz) U2004A (9 khz to 6 GHz) U2000H (10

More information

Agilent Technologies. Troubleshooting Three-Phase AC Motors with U1210 Series Handheld Clamp Meters. Application Note

Agilent Technologies. Troubleshooting Three-Phase AC Motors with U1210 Series Handheld Clamp Meters. Application Note Agilent Technologies Troubleshooting Three-Phase AC Motors with U1210 Series Handheld Clamp Meters Application Note INTRODUCTION In today s world, the three-phase AC induction motors are widely used in

More information

The Next Generation in Automated Oscilloscope Test

The Next Generation in Automated Oscilloscope Test The Next Generation in Automated Oscilloscope Test Spanning 100 MHz to 13 GHz, and varying in height from 1U to 8U, Agilent s family of LXI compliant oscilloscopes can accommodate virtually any automated

More information

Agilent Simplified PC Connections for GPIB Instruments. Application Note

Agilent Simplified PC Connections for GPIB Instruments. Application Note Agilent Simplified PC Connections for GPIB Instruments Application Note Introduction If you are an R&D, manufacturing or test engineer in the electronics industry, chances are you use your test instruments

More information

Agilent Automotive Power Window Regulator Testing. Application Note

Agilent Automotive Power Window Regulator Testing. Application Note Agilent Automotive Power Window Regulator Testing Application Note Abstract Automotive power window regulator tests require the use of accurate data acquisition devices, as they cover a wide range of parameters

More information

Agilent 87421A/87422A Power Supply

Agilent 87421A/87422A Power Supply Agilent 87421A/87422A Power Supply Technical Overview Designed specifically for Agilent Technologies microwave system amplifiers Bias cable permits remote placement Compact size for easy system integration

More information

Using a Network and Impedance Analyzer to Evaluate MHz RFID Tags and Readers/Writers

Using a Network and Impedance Analyzer to Evaluate MHz RFID Tags and Readers/Writers Using a Network and Impedance Analyzer to Evaluate 13.56 MHz RFID Tags and Readers/Writers Application Note Figure 1. Simplified RFID system Introduction RFIDs, also called non-contact IC cards or ID tags,

More information

Non-Contact Measurement Method for MHz RFID Tags Using the ENA/ENA-L Network Analyzer

Non-Contact Measurement Method for MHz RFID Tags Using the ENA/ENA-L Network Analyzer Non-Contact Measurement Method for 13.56 MHz RFID Tags Using the ENA/ENA-L Network Analyzer Application Note Measuring antenna RFID tag Measuring antenna RFID tag Figure 1. Measurement setup with reflection

More information

Signal Integrity Versus Headroom: Agilent DSO/DSA91304A Versus Tektronix DPO/DSA72004A

Signal Integrity Versus Headroom: Agilent DSO/DSA91304A Versus Tektronix DPO/DSA72004A Signal Integrity Versus Headroom: Agilent DSO/DSA91304A Versus Tektronix DPO/DSA72004A Application Note When you choose an oscilloscope, you always need to make tradeoffs. But you also need to make sure

More information

Evaluating Oscilloscope Segmented Memory for Serial Bus Applications

Evaluating Oscilloscope Segmented Memory for Serial Bus Applications Evaluating Oscilloscope Segmented Memory for Serial Bus Applications Application Note Table of Contents Introduction.... 1 Traditional Segmented Memory Applications... 3 Packetized Serial Bus Applications...

More information

PCI Express 1.0 (2.5 GT/s) Protocol Test

PCI Express 1.0 (2.5 GT/s) Protocol Test PCI Express 1.0 (2.5 GT/s) Protocol Test Configuration and Pricing Guide Gen1 today, ready for Gen2 in the future As PCI Express Gen2 becomes more mature in the market, you must decide whether to continue

More information

Agilent Effective Transformer/ LF Coil Testing. Application Note

Agilent Effective Transformer/ LF Coil Testing. Application Note Agilent Effective Transformer/ LF Coil Testing Application Note 1305-3 Introduction Transformers and LF coils are used in power supplies, digital networks (for example, ADSL) and various communication

More information

Agilent s Best-In-Class Impedance Test Instruments

Agilent s Best-In-Class Impedance Test Instruments Accelerate Your MEMS Device Development and Manufacturing Efficiency Using Agilent s Best-In-Class Impedance Test Instruments Introduction Micro Electro Mechanical Systems (MEMS) is the technology to build

More information

Troubleshooting a Variable Frequency Drive

Troubleshooting a Variable Frequency Drive Troubleshooting a Variable Frequency Drive Newsletter Introduction In many industrial and commercial plants, automation of any process and associated control relies heavily on motors and adjustable speed

More information

Differences in Application Between Power Dividers and Power Splitters. Application Note

Differences in Application Between Power Dividers and Power Splitters. Application Note Differences in Application Between Dividers and Splitters Application Note Introduction dividers are an RF microwave accessory constructed with equivalent 50Ω resistance at each port. These accessories

More information

Agilent U2000 Series USB Power Sensors

Agilent U2000 Series USB Power Sensors Agilent U2000 Series USB Power Sensors GSM Timeslot Burst Power Measurement Product Note Table of Content Introduction 2 Measuring GSM Timeslot 4 Signal Overview of Agilent U2000 5 Series USB Power Sensors

More information

Keysight Technologies N1918A Power Analysis Manager and U2000 Series USB Power Sensors. Demo Guide

Keysight Technologies N1918A Power Analysis Manager and U2000 Series USB Power Sensors. Demo Guide Keysight Technologies N1918A Power Analysis Manager and U2000 Series USB Power Sensors Demo Guide Introduction This demonstration guide helps you to get familiar with the basic setup and coniguration requirements

More information

Agilent E363xA Series Programmable DC Power Supplies. Data Sheet

Agilent E363xA Series Programmable DC Power Supplies. Data Sheet Agilent E363xA Series Programmable DC Power Supplies Data Sheet Reliable Power, Repeatable Results Single and triple output 80 W to 200 W output power Dual range output Low noise and excellent regulation

More information

PCI Express Probes for Agilent E2960B PCI Express Analysis Systems

PCI Express Probes for Agilent E2960B PCI Express Analysis Systems PCI Express for Agilent E2960B PCI Express Analysis Systems Version: 1.2 Superior Signal Probing options to address diverse designs and form factors As an industry leader in the innovation of non-intrusive,

More information

Agilent E5063A ENA Series Network Analyzer

Agilent E5063A ENA Series Network Analyzer Agilent E5063A ENA Series Network Analyzer 100 khz to 4.5/ 8.5/18 GHz Configuration Guide Ordering Guide The following steps will guide you through configuring your E5063A. Standard furnished item Description

More information

Agilent 8762/3/4A,B,C Coaxial Switches

Agilent 8762/3/4A,B,C Coaxial Switches Agilent 8762/3/4A,B,C Coaxial Switches Technical Overview High performance switches for microwave and RF instrumentation and systems Agilent Technologies offers a ver satile line of multiport coaxial switches.

More information

Agilent N5970A Interactive Functional Test Software: Installation and Getting Started

Agilent N5970A Interactive Functional Test Software: Installation and Getting Started Agilent N5970A Interactive Functional Test Software: Installation and Getting Started Application Note The N5970A Interactive Functional Test Software along with the 8960 Series 10 (E5515C) wireless communications

More information

Agilent E3640A E3649A Programmable DC Power Supplies. Data Sheet

Agilent E3640A E3649A Programmable DC Power Supplies. Data Sheet Agilent E3640A E3649A Programmable DC Power Supplies Data Sheet Reliable Power, Repeatable Results Single and dual outputs Dual range output 30 W to 100 W output power Front and rear output terminals Over-voltage

More information

Agilent Television Power Consumption Testing. Application Note

Agilent Television Power Consumption Testing. Application Note Agilent Television Power Consumption Testing Application Note Introduction Today, there are many types of televisions (TVs) on the market: the cathode ray tube (CRT) TV, liquid crystal display (LCD) TV,

More information

Agilent E6832A W-CDMA Calibration Application

Agilent E6832A W-CDMA Calibration Application Agilent E6832A W-CDMA Calibration Application For the E6601A Wireless Communications Test Set Data Sheet The next generation of mobile phone manufacturing test. E6601A is the newest test set from Agilent

More information

Agilent Mobile WiMAX R&D Test Set Solutions: Software and Technical Support Contract

Agilent Mobile WiMAX R&D Test Set Solutions: Software and Technical Support Contract Agilent Mobile WiMAX R&D Test Set Solutions: Software and Technical Support Contract Product Overview Maximize the potential of the E6651A Mobile WiMAX test set and related software with the latest software

More information

How to Measure 5 ns Rise/Fall Time on an RF Pulsed Power Amplifier Using the 8990B Peak Power Analyzer

How to Measure 5 ns Rise/Fall Time on an RF Pulsed Power Amplifier Using the 8990B Peak Power Analyzer How to Measure 5 ns Rise/Fall Time on an RF Pulsed Power Amplifier Using the 8990B Peak Power Analyzer Application Note Introduction In a pulsed radar system, one of the key transmitter-side components

More information

Accelerate Program Development using Agilent Command Expert with Microsoft Visual Studio

Accelerate Program Development using Agilent Command Expert with Microsoft Visual Studio Accelerate Program Development using Agilent Command Expert with Microsoft Visual Studio Application Note This application note contains two main sections: Command Expert Basics Introduces you to the Command

More information

Keysight M9485A PXIe Multiport Vector Network Analyzer. Configuration Guide

Keysight M9485A PXIe Multiport Vector Network Analyzer. Configuration Guide Keysight M9485A PXIe Multiport Vector Network Analyzer Configuration Guide 02 Keysight M9485A PXIe Multiport Vector Network Analyzer - Configuration Guide Ordering Guide The following steps will guide

More information

Agilent U2000 Series USB Power Sensors

Agilent U2000 Series USB Power Sensors Simple Setup, More Than Just a Sensor Agilent U2000 Series USB Power Sensors Power measurement without a power meter Frequency range: 9 khz to 24 GHz Dynamic range: 60 dbm to +20 dbm Internal zeroing capability

More information

Agilent 4338B Milliohm Meter

Agilent 4338B Milliohm Meter Agilent 4338B Milliohm Meter 10 µω to 100 kω Technical Overview Introduction Ideal for precise measurements of extremely low resistances using an ac test signal, the Agilent Technologies 4338B suits bench-top

More information

Building Hybrid Test Systems, Part 1

Building Hybrid Test Systems, Part 1 Building Hybrid Test Systems, Part 1 Laying the groundwork for a successful transition Application Note 1465-32 In the 1990s, GPIB- and VXI-based systems dominated test system architectures. With the introduction

More information

Using Agilent Command Expert with Microsoft Excel

Using Agilent Command Expert with Microsoft Excel Using Agilent Command Expert with Microsoft Excel Application Note...for fast and easy instrument control! About Agilent Command Expert Agilent Command Expert is a FREE software application that provides

More information

Keysight Technologies Connecting Data Acquisition Systems to a Wireless Network

Keysight Technologies Connecting Data Acquisition Systems to a Wireless Network Keysight Technologies Connecting Data Acquisition Systems to a Wireless Network Application Brief Test Challenges: Designing heating and air conditioning (HVAC) systems Collecting data on a remotely located

More information

Installation Guide. 85070E Dielectric Probe Kit 85071E Materials Measurement Software

Installation Guide. 85070E Dielectric Probe Kit 85071E Materials Measurement Software Installation Guide This guide provides instructions for installing and configuring the following software products: 85070E Dielectric Probe Kit 85071E Materials Measurement Software Agilent Part Number:

More information

The Advantages Of Remote Labs In Engineering Education

The Advantages Of Remote Labs In Engineering Education The Advantages Of Remote Labs In Engineering Education Doru Popescu 1, Barry Odbert 2 Application Note Abstract This paper will examine technologies that enable remote engineering labs in education. Examples

More information

Agilent BenchVue Software (34840B) Data capture simplified. Click, capture, done. Data Sheet

Agilent BenchVue Software (34840B) Data capture simplified. Click, capture, done. Data Sheet Agilent BenchVue Software (34840B) Data capture simplified. Click, capture, done. Data Sheet Use BenchVue software to: Visualize multiple measurements simultaneously Easily capture data, screen shots and

More information

N2860A 3000 Series Scope Connect Software N2861A Communications Module

N2860A 3000 Series Scope Connect Software N2861A Communications Module N2860A 3000 Series Scope Connect Software N2861A Communications Module Data Sheet N2860A Scope Connect software Easily manage and transfer data using the 3000 Series built-in USB port or the optional GPIB

More information

802.11ac Power Measurement and Timing Analysis

802.11ac Power Measurement and Timing Analysis 802.11ac Power Measurement and Timing Analysis Using the 8990B Peak Power Analyzer Application Note Introduction There are a number of challenges to anticipate when testing WLAN 802.11ac [1] power amplifier

More information

Agilent U2531A USB Simultaneous Sampling DAQ in Power Measurement Unit Monitoring. Application Note

Agilent U2531A USB Simultaneous Sampling DAQ in Power Measurement Unit Monitoring. Application Note Agilent U2531A USB Simultaneous Sampling DAQ in Power Measurement Unit Monitoring Application Note Introduction Mobile devices are getting more and more popular. The mobile phone in the market now has

More information

Testing Radar Transmitter Amplitude and Timing Stability using the Agilent 8990B Peak Power Analyzer

Testing Radar Transmitter Amplitude and Timing Stability using the Agilent 8990B Peak Power Analyzer Testing Radar Transmitter Amplitude and Timing Stability using the Agilent 8990B Peak Power Analyzer Application Note Introduction During the design, manufacturing, or even maintenance of a radar transmitter,

More information

Troubleshooting VFDs with Low Pass Filter

Troubleshooting VFDs with Low Pass Filter Troubleshooting VFDs with Low Pass Filter Application Note Introduction Today, three-phase induction motors are the most important workhorses in industry and commercial facilities. An AC induction motor

More information

Agilent MATLAB Data Analysis Software Packages for Agilent Oscilloscopes

Agilent MATLAB Data Analysis Software Packages for Agilent Oscilloscopes Agilent MATLAB Data Analysis Software Packages for Agilent Oscilloscopes Data Sheet Enhance your InfiniiVision or Infiniium oscilloscope with the analysis power of MATLAB software Develop custom analysis

More information

U7248A High Speed Inter-Chip (HSIC) Electrical Test Software Infiniium Oscilloscopes

U7248A High Speed Inter-Chip (HSIC) Electrical Test Software Infiniium Oscilloscopes U7248A High Speed Inter-Chip (HSIC) Electrical Test Software Infiniium Oscilloscopes Data Sheet This application is available in the following license variations Order N7248A for user-installed license

More information

Agilent FieldFox Remote Viewer

Agilent FieldFox Remote Viewer Agilent FieldFox Remote Viewer Application Brief Agilent Remote Viewer setup instructions The FieldFox remove viewer is a FREE ios application which allows you to view an Agilent FieldFox analyzer from

More information

Testing WiMAX receiver performance in a faded environment using Agilent s E6651A with an Azimuth ACE MX radio channel emulator.

Testing WiMAX receiver performance in a faded environment using Agilent s E6651A with an Azimuth ACE MX radio channel emulator. Testing WiMAX receiver performance in a faded environment using Agilent s E6651A with an Azimuth ACE MX radio channel emulator Application Note 1 Summary As a part of the certification regime the Mobile

More information

PXI and AXIe Modular Instrumentation

PXI and AXIe Modular Instrumentation PXI and AXIe Modular Instrumentation M9018A PXIe Chassis M9502A AXIe Chassis M9505A AXIe Chassis U4002A Digital Test Console Chassis Tested Computer List Technical Note DISCOVER the Alternatives......

More information

Agilent E6831A GSM/GPRS/EGPRS Calibration Application

Agilent E6831A GSM/GPRS/EGPRS Calibration Application Agilent E6831A GSM/GPRS/EGPRS Calibration Application For the E6601A Wireless Communications Test Set Data Sheet E6601A Features CW, AM, FM, DSB-SC source modulation RF analyzer Spectrum monitor Transmitter

More information

Testing WiMAX receiver performance in a multipath propagation environment using Agilent s E6651A with an EB Propsim C8 radio channel emulator

Testing WiMAX receiver performance in a multipath propagation environment using Agilent s E6651A with an EB Propsim C8 radio channel emulator Testing WiMAX receiver performance in a multipath propagation environment using Agilent s E6651A with an EB Propsim C8 radio channel emulator Application Note 1 Summary Introduction As a part of the certification

More information

Agilent E363xA Series Programmable DC Power Supplies. Data Sheet

Agilent E363xA Series Programmable DC Power Supplies. Data Sheet Agilent E363xA Series Programmable DC Power Supplies Data Sheet Reliable Power, Repeatable Results Single and triple output 80 W to 200 W output power Dual range output Low noise and excellent regulation

More information

Think SAFETY When Selecting a Handheld Multimeter

Think SAFETY When Selecting a Handheld Multimeter Think SAFETY When Selecting a Handheld Multimeter Application Note Introduction What do you do when you need to measure power from mains, or some other high voltage or high energy source? Should you just

More information

What is the difference between an equivalent time sampling oscilloscope and a real-time oscilloscope?

What is the difference between an equivalent time sampling oscilloscope and a real-time oscilloscope? What is the difference between an equivalent time sampling oscilloscope and a real-time oscilloscope? Application Note In the past, deciding between an equivalent time sampling oscilloscope and a real

More information

PXI and AXIe Modular Instrumentation

PXI and AXIe Modular Instrumentation PXI and AXIe Modular Instrumentation M9018A PXIe Chassis M9502A AXIe Chassis M9505A AXIe Chassis Tested Computer List Technical Note DISCOVER the Alternatives...... Agilent MODULAR Products OVERVIEW This

More information

Application Note. Double click System tray icon after service started. Click start/continue button

Application Note. Double click System tray icon after service started. Click start/continue button Procedure to Backup Agilent s Medalist Intelligent Test Framework (ITF) 3.1.1 Database and DataStore and Restore Them in a New ITF Server with SQL2000 Application Note Double click System tray icon after

More information

Agilent 8990B Peak Power Analyzer

Agilent 8990B Peak Power Analyzer Agilent 8990B Peak Power Analyzer Pulse Radar Power Measurement Demo Guide Table of Contents Introduction 2 Demonstration Preparation 3 Demo 1: 14-Pulse Characterization Measurement Demonstrate the capability

More information

Agilent Compatibility of the U2000 Series USB Power Sensors with Agilent Instruments. Application Note

Agilent Compatibility of the U2000 Series USB Power Sensors with Agilent Instruments. Application Note Agilent Compatibility of the U2000 Series USB Power Sensors with Agilent Instruments Application Note Table of Contents Introduction 2 U2000 Series USB Power 3 Sensor s Compatibility with Agilent Instruments

More information

Updating the QIAcube operating software

Updating the QIAcube operating software Updating the QIAcube operating software This document describes how to upgrade your QIAcube mainboard firmware to version P, your mainboard PLC program to version R, and your centrifuge firmware to version

More information

WD Sentinel DX4000. Small Office Storage Server. Administrator s Quick Install Guide

WD Sentinel DX4000. Small Office Storage Server. Administrator s Quick Install Guide WD Sentinel DX4000 Small Office Storage Server Administrator s Quick Install Guide Kit Contents WD Sentinel DX4000 Ethernet cable AC adapter About Your WD Product Kit Contents WD Sentinel DX4000 Small

More information

DSOX4USBSQ USB 2.0 Signal Quality Test Option for 4000 X-Series

DSOX4USBSQ USB 2.0 Signal Quality Test Option for 4000 X-Series DSOX4USBSQ USB 2.0 Signal Quality Test Option for 4000 X-Series Data Sheet Features Pass/fail test comparison standards based on low-speed, full speed, hi-speed, far-end, near end, host, and device specifications

More information

Agilent 11713B/C Attenuator/Switch Driver

Agilent 11713B/C Attenuator/Switch Driver Agilent 11713B/C Attenuator/Switch Driver Technical Overview Automate ATE systems with Agilent 11713B/C attenuator/switch driver Easy to integrate, easy to use Key Features User-friendly interface provides

More information

Keysight Technologies Making Time Domain Measurement with Pulsed Source Using SMU

Keysight Technologies Making Time Domain Measurement with Pulsed Source Using SMU Keysight Technologies Making Time Domain Measurement with Pulsed Source Using SMU B2900A Precision Source/Measure Unit Demo Guide 02 Keysight Making Time Domain Measurement with Pulsed Source Using SMU

More information

DDR Memory Overview, Development Cycle, and Challenges

DDR Memory Overview, Development Cycle, and Challenges DDR Memory Overview, Development Cycle, and Challenges Tutorial DDR Overview Memory is everywhere not just in servers, workstations and desktops, but also embedded in consumer electronics, automobiles

More information

Keysight Technologies The Advantages Of Remote Labs In Engineering Education

Keysight Technologies The Advantages Of Remote Labs In Engineering Education Keysight Technologies The Advantages Of Remote Labs In Engineering Education Application Note Educator s Corner Introduction The widespread availability of local area networks (LAN) and web access has

More information

Agilent Infoline Web Services. Quick Reference Guide. Scan and use your phone to go to Infoline at www.agilent.com/find/service

Agilent Infoline Web Services. Quick Reference Guide. Scan and use your phone to go to Infoline at www.agilent.com/find/service Agilent Infoline Web Services Quick Reference Guide Scan and use your phone to go to Infoline at www.agilent.com/find/service One location for all information This quick reference guide reviews the powerful

More information

Agilent Compatibility of USB Power Sensors with Agilent Instruments. Application Note

Agilent Compatibility of USB Power Sensors with Agilent Instruments. Application Note Agilent Compatibility of USB Power Sensors with Agilent Instruments Application Note Use USB Power Sensors as an Agilent Instruments Accessory Table of Contents Agilent USB Power Sensors 2 USB Power Sensor

More information

WD Sentinel DX4000. Small Office Storage Server Administrator s Quick Install Guide

WD Sentinel DX4000. Small Office Storage Server Administrator s Quick Install Guide 0 WD Sentinel DX4000 Small Office Storage Server Administrator s Quick Install Guide 1 Introduction This quick install guide steps the Administrator through the procedures for setting up the WD Sentinel

More information

WD Hard Drive Interface Guide

WD Hard Drive Interface Guide Hard Drive Interface Guide WD Hard Drive Interface Guide WD Service and Support Should you encounter any problem, please give us an opportunity to address it before returning this product. Most technical

More information

Measuring Power BJT Electrical Characteristics using the B1505A

Measuring Power BJT Electrical Characteristics using the B1505A Measuring Power BJT Electrical Characteristics using the B1505A Agilent B1505A Power Device Analyzer/Curve Tracer Application Note Introduction The Agilent B1505A Power Device Analyzer/Curve Tracer is

More information

X-Series Signal Analysis. Future-ready instruments Consistent measurement framework Broadest set of applications and software

X-Series Signal Analysis. Future-ready instruments Consistent measurement framework Broadest set of applications and software X-Series Signal Analysis Future-ready instruments Consistent measurement framework Broadest set of applications and software Arrive Ahead with X-Series We can t predict the future, but Agilent can help

More information

Agilent IMS-SIP Network Emulator Software (E6966A)

Agilent IMS-SIP Network Emulator Software (E6966A) Agilent IMS-SIP Network Emulator Software (E6966A) Notices Agilent Technologies, Inc. 2012-2013 No part of this manual may be reproduced in any form or by any means (including electronic storage and retrieval

More information

Release Notes: PowerChute plus for Windows 95 and Windows 98

Release Notes: PowerChute plus for Windows 95 and Windows 98 : PowerChute plus for Windows 95 and Windows 98 These release notes supplement the User s Guide: PowerChute plus, Version 5.0.2, for Windows 95 and Windows 98 (pc98ug.pdf) and the Installation Guide: PowerChute

More information

Variable Frequency Drive Troubleshooting with U1610A/U1620A

Variable Frequency Drive Troubleshooting with U1610A/U1620A Variable Frequency Drive Troubleshooting with U1610A/U1620A Application Note Electric motors form the backbone of most industrial and manufacturing environments. Variable frequency drives (VFDs) (also

More information

MAGPOWR Spyder Firmware Update Instruction Manual

MAGPOWR Spyder Firmware Update Instruction Manual MAGPOWR TENSION CONTROL MAGPOWR Spyder Firmware Update Instruction Manual EN Spyder and Spyder-Plus MI 850A324 B COPYRIGHT All of the information herein is the exclusive proprietary property of Maxcess

More information

AT-S39 Version 1.3 Management Software for the AT-8024 and AT-8024GB Fast Ethernet Switches. Software Release Notes

AT-S39 Version 1.3 Management Software for the AT-8024 and AT-8024GB Fast Ethernet Switches. Software Release Notes AT-S39 Version 1.3 Management Software for the AT-8024 and AT-8024GB Fast Ethernet Switches Supported Platforms Software Release Notes Please read this document before you begin to use the AT-S39 management

More information

N6171A MATLAB Data Analysis Software for Agilent Instruments

N6171A MATLAB Data Analysis Software for Agilent Instruments N6171A MATLAB Data Analysis Software for Agilent Instruments Technical Overview MATLAB is available directly from Agilent or its authorized sales partners with your instrument purchase Use MATLAB to create

More information

Keysight N6854A Geolocation System. Configuration Guide

Keysight N6854A Geolocation System. Configuration Guide Keysight N6854A Geolocation System Configuration Guide 02 Keysight N6854A Geolocation System - Configuration Guide This guide will help you configure a geolocation system that meets your needs and includes

More information

Agilent 4339B/4349B High Resistance Meters

Agilent 4339B/4349B High Resistance Meters Agilent 4339B/4349B High Resistance Meters Technical Overview Within Budget Without Compromise Introducing the Agilent Technologies 4339B and 4349B High Resistance Meters Used for Making Ultra- High Resistance

More information

Norton Ghost How to Backup & Recover Your Data

Norton Ghost How to Backup & Recover Your Data Norton Ghost 15.0 How to Backup & Recover Your Data This Quick User Guide was created under Symantec s authorization by Samsung Electronics Co., Ltd. in order to offer a streamlined data backup & recovery

More information

Frequency Domain Measurements: Spectrum Analyzer or Oscilloscope?

Frequency Domain Measurements: Spectrum Analyzer or Oscilloscope? Frequency Domain Measurements: Spectrum Analyzer or Oscilloscope? Changes in test and measurement technologies are blurring the lines between platforms and giving engineers new options Selection Guide

More information

Configuring DHCP for ShoreTel IP Phones

Configuring DHCP for ShoreTel IP Phones Configuring DHCP for ShoreTel IP Phones Network Requirements and Preparation 3 Configuring DHCP for ShoreTel IP Phones The ShoreTel server provides the latest application software and configuration information

More information

The Real Total Cost of Ownership of Your Test Equipment

The Real Total Cost of Ownership of Your Test Equipment The Real Total Cost of Ownership of Your Test Equipment White Paper Authors: Bill Lycette Corporate Quality Agilent Technologies Duane Lowenstein Test Process Analysis Mgr. Agilent Technologies Introduction

More information

Master Your MIPI M-PHY Receiver Tests How to Verify MIPI Conformance Using the J-BERT M8020A High-Performance BERT. Application Brief 1.

Master Your MIPI M-PHY Receiver Tests How to Verify MIPI Conformance Using the J-BERT M8020A High-Performance BERT. Application Brief 1. Master Your MIPI M-PHY Receiver Tests How to Verify MIPI Conformance Using the J-BERT M8020A High-Performance BERT Application Brief 1.0 Overview The wide spread and rapid development of cell phones from

More information

Methods for Characterizing and Tuning DC Inrush Current

Methods for Characterizing and Tuning DC Inrush Current APPLICATION BRIEF Methods for Characterizing and Tuning DC Inrush Current Introduction Inrush current or input surge current refers to the momentarily large surge current that occurs when you first turn

More information

Molecular Imager Gel Doc XR+ Installation Guide

Molecular Imager Gel Doc XR+ Installation Guide Molecular Imager Gel Doc XR+ Installation Guide To install your Gel Doc XR+, perform these seven steps in the following order: 1. Unpack the Gel Doc XR+ system. 2. Install Image Lab software. 3. Set up

More information

M24LRxx/CR95HF application software installation guide

M24LRxx/CR95HF application software installation guide User manual M24LRxx/CR95HF application software installation guide Introduction This user manual describes the procedures to install the different software drivers required to use the DEVKIT-M24LR-A development

More information

To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification:

To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification: PURPOSE Verify that communication is established for the following products programming option (488.2 compliant, SCPI only): DCS - M9C & DCS M130, DLM M9E & DLM-M9G & DLM M130, DHP - M9D, P series, SG,

More information

Keysight Technologies DVD Player Manufacturing Test Using Modular Instruments. Application Note

Keysight Technologies DVD Player Manufacturing Test Using Modular Instruments. Application Note Keysight Technologies DVD Player Manufacturing Test Using Modular Instruments Application Note 02 Keysight DVD Player Manufacturing Test Using Modular Instruments - Application Note Introduction Testing

More information

Foreign Taxes Paid and Foreign Source Income INTECH Global Income Managed Volatility Fund

Foreign Taxes Paid and Foreign Source Income INTECH Global Income Managed Volatility Fund Income INTECH Global Income Managed Volatility Fund Australia 0.0066 0.0375 Austria 0.0045 0.0014 Belgium 0.0461 0.0138 Bermuda 0.0000 0.0059 Canada 0.0919 0.0275 Cayman Islands 0.0000 0.0044 China 0.0000

More information

Installing and Uninstalling QIAxcel BioCalculator Software

Installing and Uninstalling QIAxcel BioCalculator Software Installing and Uninstalling QIAxcel BioCalculator Software This document describes how to install and uninstall BioCalculator Software from your computer. It also provides brief information about new RNA

More information

Agilent Test Case Manager N7649B

Agilent Test Case Manager N7649B Agilent Test Case Manager N7649B Technical Overview SIMPLE EASY SETUP USER FRIENDLY Predefined standard-based conformance test setups save time and give you confidence that your measurements are standard-compliant

More information

High-Speed Inter Connect (HSIC) Solution

High-Speed Inter Connect (HSIC) Solution High-Speed Inter Connect (HSIC) Solution HSIC Essentials Datasheet Protocol Decode Protocol decode Saves test time and resource costs. Designed for use with the MSO/DPO5000, DPO7000C, DPO/DSA/MSO70000C,

More information

Keysight Technologies Using Fine Resolution to Improve Thermal Images. Application Note

Keysight Technologies Using Fine Resolution to Improve Thermal Images. Application Note Keysight Technologies Using Fine Resolution to Improve Thermal Images Application Note Introduction Digital imaging opened up new possibilities and has been very much part of our lives since social media

More information

AN4108 Application note

AN4108 Application note Application note How to set up a HTTPS server for In-Home display with HTTPS Introduction This application note describes how to configure a simple SSL web server using the EasyPHP free application to

More information

Agilent Optical Power Meter Head Special Calibration

Agilent Optical Power Meter Head Special Calibration Agilent Optical Power Meter Head Special Calibration Data Sheet January 2010 This document describes the calibration of Agilent s optical power meter heads (81623B, 81624B, 81626B) for standard products

More information

Norton Ghost 15.0. How to copy partitions from an HDD to a Samsung SSD

Norton Ghost 15.0. How to copy partitions from an HDD to a Samsung SSD Norton Ghost 15.0 How to copy partitions from an HDD to a Samsung SSD This Quick User Guide was created under Symantec s authorization by Samsung Electronics Co., Ltd. in order to offer a simple & easy

More information

Agilent Test Solutions for Multiport and Balanced Devices

Agilent Test Solutions for Multiport and Balanced Devices Agilent Test Solutions for Multiport and Balanced Devices Duplexer test solutions 8753ES option H39/006 During design and final alignment of duplexers, it is often necessary to see both the transmit-antenna

More information

Make Better RMS Measurements with Your DMM

Make Better RMS Measurements with Your DMM Make Better RMS Measurements with Your DMM Application Note Introduction If you use a digital multimeter (DMM) for AC voltage measurements, it is important to know if your meter is giving you peak value,

More information

Remote Monitoring and Control of the R&S RTO with a Web Browser Application Note

Remote Monitoring and Control of the R&S RTO with a Web Browser Application Note Remote Monitoring and Control of the R&S RTO with a Web Browser Application Note Products: R&S RTO1012 R&S RTO1014 R&S RTO1022 R&S RTO1024 This application note describes remote operation or monitoring

More information

Disclaimers. Important Notice

Disclaimers. Important Notice Disclaimers Disclaimers Important Notice Copyright SolarEdge Inc. All rights reserved. No part of this document may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means,

More information

Peripheral Server R E M O T E I/O C O N C E N T R A T O R. Installation Guide

Peripheral Server R E M O T E I/O C O N C E N T R A T O R. Installation Guide Peripheral Server R E M O T E I/O C O N C E N T R A T O R Installation Guide Table of Contents Introduction... 1 Cabling Peripheral Server... 1 Installing the Drivers... 1 Configuring Your Concentrator...

More information