Small PV Systems Performance Evaluation at NREL's Outdoor Test Facility Using the PVUSA Power Rating Method
|
|
|
- Daniella Lawrence
- 10 years ago
- Views:
Transcription
1 National Renewable Energy Laboratory Innovation for Our Energy Future A national laboratory of the U.S. Department of Energy Office of Energy Efficiency & Renewable Energy Small PV Systems Performance Evaluation at NREL's Outdoor Test Facility Using the PVUSA Power Rating Method Conference Paper November 2005 Presented at the 2005 DOE Solar Energy Technologies Program Review Meeting November 7 10, 2005 Denver, Colorado NREL is operated by Midwest Research Institute Battelle Contract No. DE-AC36-99-GO10337
2 NOTICE The submitted manuscript has been offered by an employee of the Midwest Research Institute (MRI), a contractor of the US Government under Contract No. DE-AC36-99GO Accordingly, the US Government and MRI retain a nonexclusive royalty-free license to publish or reproduce the published form of this contribution, or allow others to do so, for US Government purposes. This report was prepared as an account of work sponsored by an agency of the United States government. Neither the United States government nor any agency thereof, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States government or any agency thereof. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States government or any agency thereof. Available electronically at Available for a processing fee to U.S. Department of Energy and its contractors, in paper, from: U.S. Department of Energy Office of Scientific and Technical Information P.O. Box 62 Oak Ridge, TN phone: fax: mailto:[email protected] Available for sale to the public, in paper, from: U.S. Department of Commerce National Technical Information Service 5285 Port Royal Road Springfield, VA phone: fax: [email protected] online ordering: Printed on paper containing at least 50% wastepaper, including 20% postconsumer waste
3 Small PV Systems Performance Evaluation at NREL s Outdoor Test Facility Using the PVUSA Power Rating Method National Renewable Energy Laboratory, 1617 Cole Blvd. Golden, CO [email protected] ABSTRACT The PV Systems Performance and Reliability R & D group currently has seven grid-tied 1-2 kilowatt PV systems deployed at NREL s Outdoor Test Facility (OTF) and two 6 kilowatt systems mounted on the roof of NREL s Solar Energy Research Facility (SERF). The systems, which employ several PV module technologies including crystalline silicon (c-si), amorphous silicon (a-si), cadmium telluride (CdTe), and copper indium diselenide (CIS), are being monitored to determine the long-term performance and reliability of the modules and arrays under actual field conditions. The length of observation ranges from 2 months for our newest system to 11 years for our oldest systems. The annual degradation and seasonal fluctuation of the systems power output are calculated using the PV for Utility-Scale Applications (PVUSA) power rating regression model. 1. System Descriptions A typical 1kW system consists of anywhere between 5 modules for larger and/or high efficiency c-si modules and 53 for smaller and/or lower efficiency a- Si modules. Strings of series wired modules are combined in parallel and both held at the system maximum power point and connected to the utility grid through an inverter. System voltages range from 35V to ~250V while system currents range from 2.5A to 17A. All of the OTF systems face true south and are mounted at a (latitude) tilt of 40 degrees with the exception of one system, which is mounted at a 30 degree tilt. Mounting systems at the OTF include Uni- Strut rack mounts, pole mounts and a simulated roof mount for an array of combination shingle/modules (see Figure 1). Fig. 1. Typical OTF rack mounted PV system. The two SERF systems are mounted on the SERF roof and face 158 o (22 o east of south) with a tilt angle from the horizontal equal to 45 due to building constraints. Kipp and Zonen CM11 thermopile pyranometers and Campbell Scientific 107 thermistor temperature probe are mounted in the plane-of-array of each system to measure POA irradiance and ambient temperature, respectively. Campbell Scientific or National Instruments data acquisition systems (DAS) record in-situ data for the PV systems, which are is instrumented with sensors to measure various system parameters (see Figure 2). Parameters measured and recorded for the PV systems include: plane-of-array (POA) irradiance, DC voltage, DC current, AC power, and ambient temperature. DC power is calculated by the DAS by multiplying the DC voltage and DC current. Wind speeds are recorded with a Campbell Scientific DAS from NREL s Reference Meteorological and Irradiance System (RMIS), also located at the OTF, just north of most of the systems. Measurements are made every 5 s and stored as 15-min averages for the PV systems and 1-min averages for the RMIS wind speed data. Fig. 2. Typical DAS using Campbell Scientific data logger. 2. PVUSA power rating analysis The annual degradation and seasonal fluctuation of the PV system power output are calculated using the PVUSA power rating regression model. The PVUSA rating system is based on the assumption that array current primarily depends on irradiance and that array voltage primarily depends on array temperature which, in turn, depends on irradiance, ambient temperature, and wind speed [2]. Measured data can be used to calculate a best-fit correlation to the following equation: 1
4 P = I POA (a + bi POA + ct amb + dw), where: P = power (AC or DC), kw I POA = POA irradiance, W/m 2 T amb = ambient temperature, o C W = wind speed, m/s a,b,c,d = regression coefficients derived from operational data One-month blocks of 15-min average system performance and meteorological observations are used to obtain the regression coefficients above. Because the PVUSA model performance is poor at low irradiances, the POA irradiance inputs to the regression equation are restricted to I POA > 800 W/m 2. The measured power is restricted to P DC > ~0.75 P DCmax to eliminate data points where the array may be snow covered while the pyranometer is not. After determining the regression coefficients, we find the PVUSA power rating for the system for each one month block by normalizing to PVUSA test conditions (PTC), where PTC conditions are defined as 1000 W/m 2 POA irradiance, 20 o C ambient temperature, and 1 m/s wind speed. National Instrument s LabVIEW programs, originally developed at NREL by Keith Emery and modified for this paper, are used to combine the USSC data with the RMIS wind speed data and to perform the linear regression. LabVIEW s general linear-fit function was used to determine the set of linear coefficients using the least chi-square method. Monthly power ratings are then plotted to show the system performance vs. time. 3. Results and Accomplishments Figure 3 depicts a typical a-si system plot of PVUSA DC power rating vs. from September 1999 through July 2005 for irradiances greater than 800 W/m 2 and system power greater than 1100 W DC. The analysis clearly shows the initial six months to one year of rapid degradation (-7.25% from September 1999 to August 2000 in this case) characteristic of a-si modules, followed by the typical seasonal oscillating power output also characteristic of a-si modules, i.e. higher power output in the warmer summer months. The yearly maximum and minimum power ratings for this system varied by +6.6% and -3.8%, respectively, from the yearly mean power rating. In a paper summarizing performance characterization of a-si modules from several manufacturers, Sandia National Laboratories found that previously unexposed a-si modules showed an initial rapid degradation in power over the first 6 months and reached a stabilized power level, about 20% below the initial (1 st day) power after about one year. Seasonal oscillation is usually ±4% from the stabilized level [1]. Through the PVUSA analysis described in this paper, we have observed annual degradations of between 1 and 3 percent per year. The photovoltaic (PV) industry wants a module technology that will last 30 years in the field. A PV module fails to provide service if its power output decreases by more than 30% after 30 years in its use environment. 2 Through careful measurement and analysis by the methods described above, we can identify possible failure mechanisms and help to determine solutions to these problems. REFERENCES 1. D. King, J. Kratochvil, and W. Boyson,. Stabilization and Performance Characteristics of Commercial Amorphous-Silicon PV Modules, Proc. 28 th IEEE PVSC, 2000, p T. J. McMahon, G. J. Jorgensen, and R. L. Hulstrom, Module 30 Year Life: What Does it Mean and Is it Predictable/Achievable?, Proc of the IEEE PV Spec. Conf. (2000) % (first year) Power Rating (W) % (-23.2 W) per year Aug-99 Feb-00 Aug-00 Feb-01 Aug-01 Feb-02 Aug-02 Feb-03 Aug-03 Feb-04 Aug-04 Feb-05 Time Fig. 3. PVUSA power rating vs. time plot for typical a- Si system. 2
5 REPORT DOCUMENTATION PAGE Form Approved OMB No The public reporting burden for this collection of information is estimated to average 1 hour per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing the burden, to Department of Defense, Executive Services and Communications Directorate ( ). Respondents should be aware that notwithstanding any other provision of law, no person shall be subject to any penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THE ABOVE ORGANIZATION. 1. REPORT DATE (DD-MM-YYYY) November REPORT TYPE Conference Paper 4. TITLE AND SUBTITLE Small PV Systems Performance Evaluation at NREL's Outdoor Test Facility Using the PVUSA Power Rating Method 3. DATES COVERED (From - To) 5a. CONTRACT NUMBER DE-AC36-99-GO b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) 5d. PROJECT NUMBER 5e. TASK NUMBER PVB f. WORK UNIT NUMBER 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) National Renewable Energy Laboratory 1617 Cole Blvd. Golden, CO PERFORMING ORGANIZATION REPORT NUMBER 9. SPONSORING/MONITORING AGENCY NAME(S) AND ADDRESS(ES) 10. SPONSOR/MONITOR'S ACRONYM(S) NREL 11. SPONSORING/MONITORING AGENCY REPORT NUMBER 12. DISTRIBUTION AVAILABILITY STATEMENT National Technical Information Service U.S. Department of Commerce 5285 Port Royal Road Springfield, VA SUPPLEMENTARY NOTES 14. ABSTRACT (Maximum 200 Words) The PV Systems Performance and Reliability R & D group currently has seven grid-tied 1-2 kilowatt PV systems deployed at NREL s Outdoor Test Facility (OTF) and two 6 kilowatt systems mounted on the roof of NREL s Solar Energy Research Facility (SERF). The systems, which employ several PV module technologies including crystalline silicon (c-si), amorphous silicon (a-si), cadmium telluride (CdTe), and copper indium diselenide (CIS), are being monitored to determine the long-term performance and reliability of the modules and arrays under actual field conditions. The length of observation ranges from 2 months for our newest system to 11 years for our oldest systems. The annual degradation and seasonal fluctuation of the systems power output are calculated using the PV for Utility-Scale Applications (PVUSA) power rating regression model. 15. SUBJECT TERMS Photovoltaics; solar; small PV systems; PVUSA power rating; PV; NREL 16. SECURITY CLASSIFICATION OF: 17. LIMITATION 18. NUMBER 19a. NAME OF RESPONSIBLE PERSON OF ABSTRACT OF PAGES a. REPORT b. ABSTRACT c. THIS PAGE Unclassified Unclassified Unclassified UL 19b. TELEPONE NUMBER (Include area code) Standard Form 298 (Rev. 8/98) Prescribed by ANSI Std. Z39.18
Regional Field Verification Operational Results from Four Small Wind Turbines in the Pacific Northwest
National Renewable Energy Laboratory Innovation for Our Energy Future A national laboratory of the U.S. Department of Energy Office of Energy Efficiency & Renewable Energy Regional Field Verification Operational
Optical Blade Position Tracking System Test
National Renewable Energy Laboratory Innovation for Our Energy Future A national laboratory of the U.S. Department of Energy Office of Energy Efficiency & Renewable Energy Optical Blade Position Tracking
A New Empirical Relationship between Thrust Coefficient and Induction Factor for the Turbulent Windmill State
National Renewable Energy Laboratory Innovation for Our Energy Future A national laboratory of the U.S. Department of Energy Office of Energy Efficiency & Renewable Energy A New Empirical Relationship
Elastomer Compatibility Testing of Renewable Diesel Fuels
National Renewable Energy Laboratory Innovation for Our Energy Future A national laboratory of the U.S. Department of Energy Office of Energy Efficiency & Renewable Energy Elastomer Compatibility Testing
Computer Simulations of Edge Effects in a Small-Area Mesa N-P Junction Diode
Computer Simulations of Edge Effects in a Small-Area Mesa N-P Junction Diode Preprint Conference Paper NREL/CP-520-45002 February 2009 J. Appel and B. Sopori National Renewable Energy Laboratory N.M. Ravindra
Rate Analysis of Two Photovoltaic Systems in San Diego
Rate Analysis of Two Photovoltaic Systems in San Diego Technical Report NREL/TP-6A2-43537 July 2009 Elizabeth Doris, Sean Ong, and Otto Van Geet Rate Analysis of Two Photovoltaic Systems in San Diego Technical
Method to Calculate Uncertainties in Measuring Shortwave Solar Irradiance Using Thermopile and Semiconductor Solar Radiometers
Method to Calculate Uncertainties in Measuring Shortwave Solar Irradiance Using Thermopile and Semiconductor Solar Radiometers Ibrahim Reda NREL is a national laboratory of the U.S. Department of Energy,
Wind Energy and Production of Hydrogen and Electricity Opportunities for Renewable Hydrogen
National Renewable Energy Laboratory Innovation for Our Energy Future A national laboratory of the U.S. Department of Energy Office of Energy Efficiency & Renewable Energy Wind Energy and Production of
Early Fuel Cell Market Deployments: ARRA and Combined (IAA, DLA, ARRA)
Technical Report NREL/TP-56-588 January 3 Early Fuel Cell Market Deployments: ARRA and Combined (IAA, DLA, ARRA) Quarter 3 Composite Data Products Jennifer Kurtz, Keith Wipke, Sam Sprik, Todd Ramsden,
Comparison of Photovoltaic Models in the System Advisor Model
Comparison of Photovoltaic Models in the System Advisor Model Nate J. Blair Strategic Energy Analysis Center National Renewable Energy Laboratory 15013 Denver West Parkway Golden, CO 80401 [email protected]
Using HOMER Software, NREL s Micropower Optimization Model, to Explore the Role of Gen-sets in Small Solar Power Systems
National Renewable Energy Laboratory Innovation for Our Energy Future A national laboratory of the U.S. Department of Energy Office of Energy Efficiency & Renewable Energy Using HOMER Software, NREL s
Wind Forecasting stlljectives for Utility Schedule and Energy Traders
NREUCP 500 24680 UC Category: 1210 Wind Forecasting stlljectives for Utility Schedule and Energy Traders Marc N. Schwartz National Renewable Energy Laboratory Bruce H. Bailey A WS Scientific, Inc. Presented
Application Note: String sizing Conext CL Series
: String sizing Conext CL Series 965-0066-01-01 Rev A DANGER RISK OF FIRE, ELECTRIC SHOCK, EXPLOSION, AND ARC FLASH This Application Note is in addition to, and incorporates by reference, the installation
WET BULB GLOBE TEMPERATURE MEASUREMENT AT THE Y-12 NATIONAL SECURITY COMPLEX
WET BULB GLOBE TEMPERATURE MEASUREMENT AT THE Y-12 NATIONAL SECURITY COMPLEX Thomas E. Bellinger, CCM Y-12 National Security Complex Oak Ridge, Tennessee 1. INTRODUCTION To better serve the needs of the
Financing Projects That Use Clean-Energy Technologies: An Overview of Barriers and Opportunities
National Renewable Energy Laboratory Innovation for Our Energy Future A national laboratory of the U.S. Department of Energy Office of Energy Efficiency & Renewable Energy Financing Projects That Use Clean-Energy
Monitoring System Performance
Monitoring System Performance Venue: PV Module Reliability Workshop Presenter: Keith Emery and Ryan Smith Date: February 16, 2011 NREL/PR-5200-50643 NREL is a national laboratory of the U.S. Department
Measurement of BET Surface Area on Silica Nanosprings
PNNL-17648 Prepared for the U.S. Department of Energy under Contract DE-AC05-76RL01830 Measurement of BET Surface Area on Silica Nanosprings AJ Karkamkar September 2008 DISCLAIMER This report was prepared
System Advisor Model, SAM 2014.1.14: General Description
System Advisor Model, SAM 2014.1.14: General Description Nate Blair, Aron P. Dobos, Janine Freeman, Ty Neises, and Michael Wagner National Renewable Energy Laboratory Tom Ferguson, Paul Gilman, and Steven
Energy Systems Integration
Energy Systems Integration A Convergence of Ideas Ben Kroposki, Bobi Garrett, Stuart Macmillan, Brent Rice, and Connie Komomua National Renewable Energy Laboratory Mark O Malley University College Dublin
Second Line of Defense Virtual Private Network Guidance for Deployed and New CAS Systems
PNNL-19266 Prepared for the U.S. Department of Energy under Contract DE-AC05-76RL01830 Second Line of Defense Virtual Private Network Guidance for Deployed and New CAS Systems SV Singh AI Thronas January
Solar Energy Feasibility Study
Remote Power Inc. 981 Gold Mine Trail Fairbanks, AK 99712 Solar Energy Feasibility Study For a Typical On-Grid Residence in Fairbanks, AK Bruno Grunau, P.E. Greg Egan 05 November 2008 1 Abstract: Solar
Collaboration on Renewable Energy Standards, Testing, and Certification under the U.S. China Renewable Energy Partnership
Collaboration on Renewable Energy Standards, Testing, and Certification under the U.S. China Renewable Energy Partnership Preprint W. Wallace and S. Kurtz National Renewable Energy Laboratory W. Lin China
Technology Advantage
Technology Advantage 2 FIRST SOLAR TECHNOLOGY ADVANTAGE 3 The Technology Advantage Cadmium Telluride (CdTe) photovoltaic (PV) technology continues to set performance records in both research and real-world
Corona Department of Water & Power (DWP) Solar Partnership Program Guidelines and Application
Corona Department of Water & Power (DWP) Solar Partnership Program Guidelines and Application DWP s new Solar Partnership Program is available to help offset your investment in a PV system and get you
Amorphous Transparent Conducting Oxides (TCOs) Deposited at T 100 C
Amorphous Transparent Conducting Oxides (TCOs) Deposited at T 100 C John Perkins, Maikel van Hest, Charles Teplin, Jeff Alleman, Matthew Dabney, Lynn Gedvilas, Brian Keyes, Bobby To, David Ginley National
NREL Job Task Analysis: Crew Leader
NREL Job Task Analysis: Crew Leader Chuck Kurnik National Renewable Energy Laboratory Cynthia Woodley Professional Testing Inc. NREL is a national laboratory of the U.S. Department of Energy, Office of
Solar America Board for Codes and Standards
Impacts on Photovoltaic Installations of Changes to the 2012 International Codes A Solar ABCs White Paper May 2011 Solar America Board for Codes and Standards www.solarabcs.org Solar America Board for
Dynamic Vulnerability Assessment
SANDIA REPORT SAND2004-4712 Unlimited Release Printed September 2004 Dynamic Vulnerability Assessment Cynthia L. Nelson Prepared by Sandia National Laboratories Albuquerque, New Mexico 87185 and Livermore,
Auburn University s Solar Photovoltaic Array Tilt Angle and Tracking Performance Experiment
Auburn University s Solar Photovoltaic Array Tilt Angle and Tracking Performance Experiment Julie A. Rodiek 1, Steve R. Best 2, and Casey Still 3 Space Research Institute, Auburn University, AL, 36849,
Weather-Corrected Performance Ratio
Weather-Corrected Performance Ratio Timothy Dierauf and Aaron Growitz SunPower Corporation Sarah Kurtz National Renewable Energy Laboratory Jose Luis Becerra Cruz Fichtner Evan Riley Black & Veatch Clifford
Procedure for Measuring and Reporting the Performance of Photovoltaic Systems in Buildings
National Renewable Energy Laboratory Innovation for Our Energy Future A national laboratory of the U.S. Department of Energy Office of Energy Efficiency & Renewable Energy Procedure for Measuring and Reporting
DARK CURRENT-VOLTAGE MEASUREMENTS ON PHOTOVOLTAIC MODULES AS A DIAGNOSTIC OR MANUFACTURING TOOL
t DARK CURRENT-VOLTAGE MEASUREMENTS ON PHOTOVOLTAC MODULES AS A DAGNOSTC OR MANUFACTURNG TOOL D. L. King, 6. R. Hansen, J. A. Kratochvil, and M. A. Quintana Sandia National Laboratories, Albuquerque, NM
Laser Safety Audit and Inventory System Database
SAND REPORT SAND2003-1144 Unlimited Release Printed May 2003 Laser Safety Audit and Inventory System Database Arnold L. Augustoni Prepared by Sandia National Laboratories Albuquerque, New Mexico 87185
Solar Energy Systems. Matt Aldeman Senior Energy Analyst Center for Renewable Energy Illinois State University
Solar Energy Solar Energy Systems Matt Aldeman Senior Energy Analyst Center for Renewable Energy Illinois State University 1 SOLAR ENERGY OVERVIEW 1) Types of Solar Power Plants 2) Describing the Solar
Solar Power at Vernier Software & Technology
Solar Power at Vernier Software & Technology Having an eco-friendly business is important to Vernier. Towards that end, we have recently completed a two-phase project to add solar panels to our building
Validation of Multiple Tools for Flat Plate Photovoltaic Modeling Against Measured Data
Validation of Multiple Tools for Flat Plate Photovoltaic Modeling Against Measured Data Janine Freeman, Jonathan Whitmore, Nate Blair, and Aron P. Dobos NREL is a national laboratory of the U.S. Department
Grid Interconnection and Performance Testing Procedures for Vehicle-To-Grid (V2G) Power Electronics
Grid Interconnection and Performance Testing Procedures for Vehicle-To-Grid (V2G) Power Electronics Preprint William Kramer, Sudipta Chakraborty, Benjamin Kroposki, Andy Hoke, Greg Martin, and Tony Markel
Penetration Testing of Industrial Control Systems
SF-1075-SUR (8-2005) SANDIA REPORT SAND2005-2846P Unlimited Release Printed March, 2005 Penetration Testing of Industrial Control Systems David P. Duggan Prepared by Sandia National Laboratories Albuquerque,
Potential of Photovoltaics (PV) and CPV/CSP in Cyprus. University of Cyprus. Photovoltaic Technology, University of Cyprus
Potential of Photovoltaics (PV) and CPV/CSP in Cyprus University of Cyprus Photovoltaic Technology, University of Cyprus G. E. Georghiou, 29 November 2010 Acknowledgements Institute for Physical Electronics
EFFICIENT EAST-WEST ORIENTATED PV SYSTEMS WITH ONE MPP TRACKER
EFFICIENT EAST-WEST ORIENTATED PV SYSTEMS WITH ONE MPP TRACKER A willingness to install east-west orientated photovoltaic (PV) systems has lacked in the past. Nowadays, however, interest in installing
Automated Transportation Management System
- BOE/RL-93-52 Rev. 1 Automated Transportation Management System (ATMS) Configuration Management Plan /, MAR 2 2 1995 OSTI 1 United States Department of Energy Richland, Washington - Approved for Public
How To Use The Csi Ebpp Calculator
CSI EPBB Design Factor Calculator User Guide 1. Guide Overview This User Guide is intended to provide background on the California Solar Initiative (CSI) Expected Performance Based Buydown (EPBB) Design
Overview of BNL s Solar Energy Research Plans. March 2011
Overview of BNL s Solar Energy Research Plans March 2011 Why Solar Energy Research at BNL? BNL s capabilities can advance solar energy In the Northeast World class facilities History of successful research
Electrical Collection and Transmission Systems for Offshore Wind Power
National Renewable Energy Laboratory Innovation for Our Energy Future A national laboratory of the U.S. Department of Energy Office of Energy Efficiency & Renewable Energy Electrical Collection and Transmission
Design of Grid Connect PV systems. Palau Workshop 8 th -12 th April
Design of Grid Connect PV systems Palau Workshop 8 th -12 th April INTRODUCTION The document provides the minimum knowledge required when designing a PV Grid connect system. The actual design criteria
Irradiance. Solar Fundamentals Solar power investment decision making
Solar Fundamentals Solar power investment decision making Chilean Solar Resource Assessment Antofagasta and Santiago December 2010 Edward C. Kern, Jr., Ph.D., Inc. Global Solar Radiation Solar Power is
Photovoltaic Systems II EE 446/646
Photovoltaic Systems II EE 446/646 Components of a grid-connected residential PV system (net meter) The inverter contains: Ground Fault Circuit Interrupter (GFCI) MPPT and Circuitry to disconnect the PV
IDC Reengineering Phase 2 & 3 US Industry Standard Cost Estimate Summary
SANDIA REPORT SAND2015-20815X Unlimited Release January 2015 IDC Reengineering Phase 2 & 3 US Industry Standard Cost Estimate Summary Version 1.0 James Mark Harris, Robert M. Huelskamp Prepared by Sandia
Analysis of Photovoltaic System Energy Performance Evaluation Method
Analysis of Photovoltaic System Energy Performance Evaluation Method Sarah Kurtz National Renewable Energy Laboratory Jeff Newmiller DNV KEMA Renewables Evan Riley Black & Veatch Timothy Dierauf SunPower
Solar Energy. Airports Going Green Aimee Fenlon
Solar Energy Airports Going Green Aimee Fenlon 1 Renewable vs. Non-Renewable Electrical Generation Renewables: Source Advantages Disadvantages Solar PV No CO2; Needs no Fuel Intermittent no power at night,
Situated Usability Testing for Security Systems
PNNL-20201 Prepared for the U.S. Department of Energy under Contract DE-AC05-76RL01830 Situated Usability Testing for Security Systems FL Greitzer February 2011 DISCLAIMER This report was prepared as an
SUNPOWER CORPORATION Document # 001-55110 Rev *B Title: Page 1 of 8 Initial release: 17-Aug-09
Title: Page 1 of 8! "#"#$ #%&'&&((&. + /.0 0 1 2. 0-) 3 140" 3 14 ) * + ), ") ),- Objective: The objective of this document is to give general background on simulator engines, suggesting which simulators
measurements at varying irradiance spectrum, intensity and module temperature
Loughborough University Institutional Repository Performance measurements at varying irradiance spectrum, intensity and module temperature of amorphous silicon solar cells This item was submitted to Loughborough
Design of a Photovoltaic Data Monitoring System and Performance Analysis of the 56 kw the Murdoch University Library Photovoltaic System
School of Engineering and Information Technology ENG460 Engineering Thesis Design of a Photovoltaic Data Monitoring System and Performance Analysis of the 56 kw the Murdoch University Library Photovoltaic
SHARP SOLAR Frequently Asked Questions for PV Integrators Revised 05/04/2010
SHARP SOLAR Frequently Asked Questions for PV Integrators Revised 05/04/2010 How do I determine the PTC rating of a module? PTC refers to PVUSA Test Conditions, which were developed to test and compare
Solar Energy Commercial Applications. Agenda. Venture Catalyst Inc. Intro. Opportunity. Applications. Financing. How to start
Solar Energy Commercial Applications Valerie Rauluk Venture Catalyst Inc. [email protected] Solar America Cities Briefing June 23, 2009 Agenda Intro Opportunity Applications Financing How to start 2
Improving a Gripper End Effector
PNNL-13440 Improving a Gripper End Effector OD Mullen CM Smith KL Gervais January 2001 Prepared for the U.S. Department of Energy under Contract DE-AC06-76RL01830 DISCLAIMER This report was prepared as
MORE POWER. A BETTER INVESTMENT.
SUNPOWERCORP.COM US HEADQUARTERS SunPower Corporation 3939 N. 1st Street San Jose, California 95134 USA 1-800-SUNPOWER sunpowercorp.com MORE POWER. A BETTER INVESTMENT. Established Incorporated in 1985
ENERGY YIELD PREDICTION OF AMORPHOUS SILICON PV MODULES USING FULL TIME DATA SERIES OF IRRADIANCE AND TEMPERATURE FOR DIFFERENT GEOGRAPHICAL LOCATIONS
Skoczek A., Virtuani A., Cebecauer T., Chianese D., 2011. Energy Yield Prediction of Amorphous Silicon PV Modules Using Full Time Data Series of Irradiance And Temperature for Different Geographical Locations.
Overview Presented by: Boyd L. Summers
Overview Presented by: Boyd L. Summers Systems & Software Technology Conference SSTC May 19 th, 2011 1 Report Documentation Page Form Approved OMB No. 0704-0188 Public reporting burden for the collection
Yield Reduction due to Shading:
1x4 1x16 10 x CBC Energy A/S x Danfoss Solar Inverters CBC-40W Poly 40 W TLX 1,5k 5 ; 1x11 3x4 0 1,5kW 1536 x CBC Energy A/S 1 x Power-One CBC-40W Poly 40 W TRIO-7,6-TL-OUTD 30 ; 4x14 0 7,6kW Location:
Photovoltaic Incentive Program
Incentive type: Utility Rebate Program Eligible Technologies: Photovoltaic (PV) Photovoltaic Incentive Program Applicable Sector: Residential/Commercial/Industrial/Municipal System Maximum capacity: 20
Running the Electric Meter Backwards: Real-Life Experience with a Residential Solar Power System
Running the Electric Meter Backwards: Real-Life Experience with a Residential Solar Power System Brooks Martner Lafayette, Colorado University of Toledo Spring 2015 PHYS 4400 - Principles and Varieties
REQUEST FOR PROPOSALS SOLAR POWER PURCHASE AGREEMENT (PPA)
ISSUE DATE: July 24, 2015 REQUEST FOR PROPOSALS SOLAR POWER PURCHASE AGREEMENT (PPA) Proposals will be received until 2:00 P.M. Monday, August 24, 2015 for furnishing the services described herein. Email
Gross/Active PV Surface Area: 13.094,40 / 13.086,29 m². Energy Produced by PV Array (AC):
1x17 1x17 1x 8 x Trina Solar Trina TSM-PC5A 6 6 W 5 ; x Danfoss Solar Inverters TLX 1,5k 1,5kW Location: Arrondissement d'issoire Climate Data Record: Arrondissement d'issoire PV Output:.8, kwp Gross/Active
Bigger is Better: Sizing Solar Modules for Microinverters
Bigger is Better: Sizing Solar Modules for Microinverters Authors: David Briggs 1 ; Dave Williams 1 ; Preston Steele 1 ; Tefford Reed 1 ; 1 Enphase Energy, Inc. October 25, 2012 SUMMARY This study analyzed
Dynamic Programming Applied to Investigate Energy Management Strategies for a Plug-in HEV
National Renewable Energy Laboratory Innovation for Our Energy Future A national laboratory of the U.S. Department of Energy Office of Energy Efficiency & Renewable Energy Dynamic Programming Applied to
Understanding Tracker Accuracy and its Effects on CPV
Understanding Tracker Accuracy and its Effects on CPV M. Davis, T. Williams (GreenMountain Engineering) M. Martínez, D. Sanchéz (ISFOC) Presented at the 5 th International Conference on Solar Concentrators
Own Your Power! A Consumer Guide to Solar Electricity for the Home
Own Your Power! A Consumer Guide to Solar Electricity for the Home Contents Benefits of Solar Electricity.................... 1 Solar Electricity Basics........................ 2 Types of Solar Panels.........................................
ADDENDUM #1(BID PACKAGE # 3)
H2Engineering, Inc. 114 East Fifth Avenue Tallahassee, FL 32303 Phone 850.224.7922 Fax 850.224.5876 ADDENDUM #1(BID PACKAGE # 3) To: Jeff Williams From: Peter Lindstrom Co: Leon County Date: October 04,
The Planning and Design of Photovoltaic Energy Systems: Engineering and Economic Aspects. William Nichols Georgia Southern University Atlanta, GA
The Planning and Design of Photovoltaic Energy Systems: Engineering and Economic Aspects William Nichols Georgia Southern University Atlanta, GA Dr. Youakim Kalaani Georgia Southern University Statesboro,
Investigation of Performance For Fixed-Inclined, One Axis and Two-Axis Tracking Photovoltaic System in Different Parts of Turkey
Investigation of Performance For Fixed-Inclined, One Axis and Two-Axis Tracking Photovoltaic System in Different Parts of Turkey Bedretttin UZUN, Gülin Acarol ZİLANLI, Ömer AKAN, Aynur ERAY Outline pvplanner
Drupal Automated Testing: Using Behat and Gherkin
PNNL-23798 Prepared for the U.S. Department of Energy under Contract DE-AC05-76RL01830 Drupal Automated Testing: Using Behat and Gherkin Thomas Williams [email protected] Carolyn Wolkenhauer [email protected]
Central Inverter Planning of a PV Generator
Central Inverter Planning of a PV Generator Planning Guidelines DC-PL-en-11 Version 1.1 ENGLISH SMA Solar Technology AG Table of Contents Table of Contents 1 Information on this Document....................................5
Cost and Performance Assumptions for Modeling Electricity Generation Technologies
Cost and Performance Assumptions for Modeling Electricity Generation Technologies Rick Tidball, Joel Bluestein, Nick Rodriguez, and Stu Knoke ICF International Fairfax, Virginia NREL is a national laboratory
LEHI CITY POWER NET METERING STANDARDS For Customer-Owned Electric Generating Systems
LEHI CITY POWER NET METERING STANDARDS For Customer-Owned Electric Generating Systems A. General This Net Metering Standard for Customer-Owned Grid Connected Electric Generating Systems sets forth the
DEFENSE CONTRACT AUDIT AGENCY
DEFENSE CONTRACT AUDIT AGENCY Fundamental Building Blocks for an Acceptable Accounting System Presented by Sue Reynaga DCAA Branch Manager San Diego Branch Office August 24, 2011 Report Documentation Page