SUPER THERM SPECIFICATIONS & TESTS
|
|
|
- Jeffry Solomon Crawford
- 10 years ago
- Views:
Transcription
1 FEATURES 1.) As an Insulation Coating - Reflects 95% of the sum total of all three heat waves o UV 99% o Short Wave (Visual) 92% (JIS A (b) specific waves. Second testing: CRRC % (ASTM C1549) combination of a limited number of waves. o Long Wave (Infrared) 99.5% (JIS A (c) specific waves. Second testing: CRRC % (ASTM C 1549) combination of a limited number of waves o ASTM E1269 and ASTM 1461 Reduces conduction of BTU heat from down to 3.99 with one coat of SUPER THERM. o ASTM C236 Standard Test Method for Steady-State Thermal performance of Building Assemblies by Means of a Guarded Hot Box. Fiberglass at 3 rated 0.53 BTU K value. One coat of SUPER THERM at 10 dry mils rated 0.31 BTU K value and one coat applied at 10 dry mils to one side of wall and another coat applied to opposite side at 10 dry mils rated BTU K value of % better performance than the fiberglass. - Emissivity rating of 0.91 o Emits any heat absorbed from its surface at a 91% rate. Allows the coating to work on interior to stabilize the ambient air. - The Russian Academy of Sciences Institution, Institute for Solid State Physics July 2012 : Result: Reflection Coefficient% Polished Aluminum Mirror 90.4% Fresh electro-zinc coating 65.3% SUPER THERM sample % SUPER THERM sample % SUPER THERM sample % SUPER THERM sample % Conclusion: Total coefficients of diffuse light reflection for SUPER THERM coat samples in visible band are consistent with (and even several percentages higher) aluminum mirror reflection coefficient, and are substantially higher than reflection coefficients of galvanized iron and duralumin. It is understood that blocking the heat load over a facility is more effective than allowing 100% of the heat load to occur and then using a standard batt insulation to absorb and offer an R value to slow the heat from conducting into the facility. The R value is only : the recorded time it takes for the total heat load to pass through the material from the loaded side to the cool side.
2 Then the question becomes, once the material is fully loaded with heat do you still have any R value at that point? There is no resistance based on initial loading because there is a steady flow of heat to the cool side. Also, once the batt material is loaded and the sun goes down, the batt is fully loaded with heat and will take hours to finish unloading the heat into the cool side before the A/C can cycle. NB: If you never load heat, the facility never absorbs and holds heat, therefore, keeping the facility cool and when the sun goes down, it is immediately cool causing the A/C to cycle or shut down. 2.) As a Water Barrier Coating - ASTM D 6904 Resistance to Wind Driven Rain for Exterior Coatings ASTM D 7088 Resistance to hydrostatic Pressure for Coatings Passed all testing standard to 55 mph wind driven rain. 3.) As a Flame & Smoke Retardant - ASTM E Flame Spread and 0 Smoke - External fire performance BRoof(t2) according to ENV 1187-A / UNI EN ) As a Sound Reducer - ASTM E90 Standard Method for Laboratory measurement of Airborne Sound Transmission Loss of building Partitions. - ASTM E413 Standard Classification for Determination of sound Transmission Class. - Both sides total accumulative result is STC 41 - Talking range of 1000 Hz to 1600 Hz STC 50 and again at 5000 Hz 5.) As a Mold / Mildew Resister - ASTM D T tested for severe mold environment Temp 90F and RH of 95%-98% for 5 ½ weeks. Rated 9 out of ) As a Condensation Controller - Field Study Testing 7.) Static Coefficient of Friction is an average of 1.14 when tested in Kinetic Coefficient of Friction is and average of 0.78.
3 CERTIFICATIONS UL, FM, ABS, ENERGY STAR, California Bureau of Home Furnishings and Thermal Insulation, ICC (International Code Council #21-25), CRRC (Cool Roof Rating Council Emissivity of 0.91), JIS (Japanese Institute of Standards) A US GREEN BUILDING COUNCIL- Certified, LEED program, MBDC Cradle to Cradle Program Gold Certificate for LEED and Environment, USDA approval letter and US Consumer Council approved. LABORATORY TESTS 1. ASTM (American Society for Testing and Materials) - ASTM B177 - Salt spray (fog) corrosion tests, 450h exposure (Passed) - ASTM C177 - Standard Test Method for Steady-State Heat Flux Measurements and Thermal Transmission Properties by Means of the Guarded-Hot-Plate Apparatus (Passed) - ASTM C236 - Standard Test Method for Steady-State Thermal Performance of Building Assemblies by Means of a Guarded Hot Box - Testing for measuring R-values (Passed) - ASTM C411 - Standard Test Method for Hot-Surface Performance of High-Temperature Thermal Insulation (Passed) - ASTM C Standard Test Method for Determination of Emittance of Materials Near Room Temperature Using Portable Emissometers (Passed) - ASTM C Standard Test Method for Determination of Solar Reflectance Near Ambient Temperature Using a Portable Solar Reflectometer (Passed) - ASTM D412 - Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers- Tension - Tensile strength psi, modulus of elasticity 13,248 psi (Passed) - ASTM D522 - Standard Test Methods for Mandrel Bend Test of Attached Organic Coatings (resistance to cracking on metal or rubber type materials / 1"(25mm)bend / 1/4"(96mm)bend) (Passed) - ASTM D Standard Test Methods for Water Vapor Transmission of Organic Coating Films (Passed 3%) - ASTM D Standard Test Method for Evaluation of Painted or Coated Specimens Subjected to Corrosive Environments Salt spray (fog/weathering) 450 Hour Salt Spray (Fog) (Passed hours) -
4 - ASTM D T - Standard Test Method for Resistance to Growth of Mold on the Surface ofinterior Coatings in an Environmental Chamber (Passed) - UV & Salt Spray Resistance (ASTM 5894) 5000 hours - ASTM D Standard Test Method for Evaluating Degree of Surface Disfigurement of Paint Films by Microbial (Fungal or Algal) Growth or Soil and Dirt Accumulation (Rating degree of fungal growth or soil and dirt accumulation on paint film) (Passed - Excellent (8 out of 9)) - ASTM D Standard Test Method for Measuring Adhesion by Tape Test (Rated: 5B) - ASTM D Standard Test Method for Abrasion Resistance of Organic Coatings by the Taber Abraser (Passed) - ASTM D Standard Practice for Resistance to Wind-Driven Rain for Exterior Coatings Applied to Masonry (3000 cycles) - ASTM D Standard Practice for Resistance to Hydrostatic Pressure for Coatings Used in Below Grade Applications Applied to Masonry (Passed) - ASTM E84-89a - Standard Test Method for Surface Burning Characteristics of Building Materials (Flame Index "0" / Smoke Index "0" - Class "A" Rating) (Passed - "0" development) - ASTM E90 - Standard test method for laboratory measurement of airborne sound transmission loss of building partitions (Passed) - ASTM E96 - Standard Test Methods for Water Vapor Transmission of Materials water vapor transmission (Perm Rating avg) - ASTM E108 - Standard Test Method for Fire Tests of Roof Coverings (Passed) - ASTM E413 - Standard Classification for Determination of Sound Transmission Class (STC 40 to 50 based on sound frequency) - ASTM E514 - Standard Test Method for Water Penetration and Leakage Through Masonry Resistance to Wind Driven Rain (Passed) - ASTM E Standard Test Method for Solar Absorptance, Reflectance, and Transmittance of Materials Using Integrating Spheres (Passed) - ASTM E Year Retest (Passed) - ASTM E Standard Test Method for Determining Specific Heat Capacity by Differential Scanning Calorimetry - TPRL (Passed) - ASTM E Standard Test Method for Thermal Diffusivity of Solids by the Flash Method (Passed) - ASTM E Test Method for J-Integral Characterization of Fracture Toughness Flexibility (Passed) - ASTM G53 - exposure to UV, elevated temperature and humidity (Passed)
5 2. NASA (National Aeronautics and Space Administration) - NHB B/C Test 1- Flammability testing ("0" Burn, Class "A" rating) (Passed) - NHB C, Test 7 - Toxic Off gassing ("K" no Toxic off gassing / "K" Rating for toxicity) (Passed) 3. ICC (International Code Council) Council that formally consolidates approvals for: - BOCA (Building Officials Code Administrators) o Section Exposed installations, Thermal insulation o Section Concealed installations, Thermal insulation o Section Classification, Interior finish o 1998 International Mechanical Code o Section Coverings and Linings, Insulation - ICBO (Intl Conference of Building Officials) *SBCCI (Southern Building Code Congress Intl) o Passed ASTM E 84 For Flame Spread o Passed ASTM C 411 for High Temperature for Surface Performance o Section Classification, Interior finish o Passed ASTM C 177 for Thermal Conductivity 4. ECAP-CUL ENERGY CONSERVATION ASSISTANCE PROGRAM Standard Method for Comparing Utility Loads in Standard Constructed Buildings - FLORIDA: ECAP REPORT (report available on request) - DENVER: ECAP REPORT (report available on request) o "This is the second time we have had the pleasure to test your product, it is rare that a single product will show such Repeatable Results in two totally different
6 environments, South Florida and Denver Colorado, a true testimonial to your products ENERGY STAR rating." Alexander Othmer - Director FEO Energy Conservation Assistance / USF Tampa, Florida - TEXAS: Container ECAP Report Houston (report available on request) o "This is the third time we have had the pleasure to test SuperTherm product, it is rare that a single product will show such Repeatable Results in three totally different environments, South Florida and Denver Colorado and LaPorte Texas a true testimonial to your products ENERGY STAR rating." 5. ASHRAE (The American Society of Heating, Refrigerating and Air-Conditioning Engineers) CODE COMPLIANCE ( U value used to measure area-weighted average, insulated walls or roofs) 6. ENERGY STAR PROGRAM Approved and accepted as an energy star partner for saving energy - ASTM E Reflectivity = 80% - Only 1% Reduction in Reflectivity over 3 Years (3% over 10 years) - ASTM C 1371 and C 1549 Solar Reflectance and Thermal Emittance 7. LEED (Leadership in Energy & Environmental Design) - Qualifies under Sustainable Sites Credit 7.1 Heat Island Effect - non roof (1 point) - Qualifies under Sustainable Sites Credit 7.2 Heat Island Effect - roof (1 point) - Qualifies under Energy and Atmosphere Credit 1 Optimize Energy Performance ie. reduce thermal bridging (1-10 point) - Indoor Environmental Quality Credit 4.2 Low Emitting Materials - paint (1 point)
7 - Innovation & Design Process Credit 1.1 Innovation in Design (5 point) - Under Category CORE AND SHELL in the latest 2009 LEED program: o SS Credit 7.2 Heat Island Effect: Roof - 1 point for having a SRI above 78 (ST-120) o EA Credit 1: Optimize Energy Performance 1-21 Points SUPER THERM 17 points. - MBDC Cradle to Cradle GOLD CERTIFICATION - LEED Rating System (available upon request) 8. FACTORY MUTUAL - Factory Mutual Approval - Tested and Approved for Roofing and all other Applications - Superior Products International II, Inc. is an active member of the NRCA. (National Roofing Contractors Association) 9. JISC (Japanese Industrial Standards Corporation) - JIS A 5759 Reflectivity of sunlight on window or coating film (Passed) - Reflective ratio Long Wave Radiation ratio 99.5 (Infrared) (Passed) - 15 Year Re Test Solar Reflectance JIS R 3106 (Passed) 10. USDA (United States Department of Agriculture) - Environmentally safe and safe for use around animals - Letter of Written Certification as Accepted by USDA from Manufacturer (available upon request)
8 11. China Center for Technical Testing of Non-Metallic Materials for Ship Building, China Ship- Building Corporation National Bureau for the Inspection of Technologies (97), Measurement Approval (National) No. (M0729) (Passed hours) - GB/T Resistance to Salt Fog (2000 hours) (Passed) - GB/T Manual Aging (2000 hours) (Passed) - GB/T Resistance to Salt Water (1000 hours) (Passed) - GB/T Adhesion (pulling apart method) (4.07MPa) - GB/T Boiling Water Immersion (8 Hours) 12. VOC 24 grams/ litre 13. IMO (International Marine Organization) - IMO A. 653 (16) - Flame Spread Test for Bulkhead, Wall, and Ceiling Linings (Passed) 14. Marine Safety Council - MSC.41 (64) - Toxic Gas Generation, Used Colorimetric Gas Detector Tubes, Met All Toxic Gas Requirements (Passed) 15. SOUND PROOFING Barrier - Sound Reduction: STC (Sound Transmission Coefficient)-Rated per ASTM E 90 - Stoughton Trailer Ultra Sound testing shows a 68% Reduction - Sound testing performed by Hot-Cold Air and Fire Control by Pat Saulson, PhD - Sound reduced an average of 50.2% by using SuperTherm on the interior walls of a house
9 16. USDA (US Dept. of Agriculture) approved for use around foods- no off gassing 17. GREEN LABEL - Certified means that an examination of samples of a Product or investigation has been performed by the Council to determine compliance with the Guidelines and that permission has been granted in accordance with this Agreement for the User to represent its Product as Certified. 18. US FEDERAL AUTHORIZED VENDOR AND CONTRACTOR APPROVAL STAMP FOR SELLING DIRECTLY TO US GOVERNMENT AGENCIES AND MILITARY LIMITATION OF LIABILITY: All recommendations or suggestions relating to the use of the products, whether in technical documentation, or in response to a specific enquiry, or otherwise, are based on data which to the best of our knowledge is reliable. The products and information are designed for users having the requisite knowledge and industrial skills, and the end-user has the responsibility to determine the suitability of the product for its intended use. SPE has no control over either the quality of condition of the substrate, or the many factors affecting the use and application of the product. Therefore, SPE does not accept any liability arising from loss, injury, or damage resulting from such use or the contents of this data sheet. The information contained in this data sheet is subject to modification as a result of practical experience and continuous product development. This data sheet replaces and annuls all previous issues and the user has the responsibility to ensure that this sheet is current prior to using the product. Apr-15
CERTIFICACIONES Y PRUEBAS DE LABORATORIO
CERTIFICACIONES Y PRUEBAS DE LABORATORIO 1. ASTM (American Society for Testing and Materials): ASTM B177 - Salt spray (fog) corrosion tests, 450h exposure (Passed) ASTM C177 - Standard Test Method for
FIELD TESTING SERVICES
FIELD TESTING SERVICES Chris Leach Director of Testing Baton Rouge, Louisiana Destin, Florida Scott Leach David Nichols Field Testing Representative Field Testing Representative 17485 Opportunity Avenue
07 21 19 Guide Specification STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM
07 21 19 STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM 7819 Broadview Road Cleveland, OH 44131 800-522-4522 February, 2011 SPEC NOTE: This guide specification is intended for use when specifying
SECTION 07560 FLUID APPLIED ROOFING (LIGHT TRAFFIC DECKS OVER CONCRETE)
SECTION 07560 FLUID APPLIED ROOFING (LIGHT TRAFFIC DECKS OVER CONCRETE) PART 1 GENERAL 1.1 DESCRIPTION 1. Fluid applied flexible acrylic waterproofing system over concrete. This work shall include the
Fiberglas, Exterior Wall Thermal Insulation
PROJECT ENGINEER RESPONSIBILITY: This is a general specification guide, intended to be used by experienced construction professionals, in conjunction with good construction practice and professional judgment.
EcoTouch Insulation with PureFiber Technology
PROJECT ENGINEER RESPONSIBILITY: This is a general specification guide, intended to be used by experienced construction professionals, in conjunction with good construction practice and professional judgment.
Global Hybrid Roofing Solutions (Delaware) LLC
Global Hybrid Roofing Solutions (Delaware) LLC Product ing Summary Distributed by: BEST MATERIALS LLC Ph: 800-474-7570, 602-272-8128 Fax: 602-272-8014 Email: [email protected] www.bestmaterials.com
Residential Windows, 3 rd edition Corrected index 1
Residential Windows, 3 rd edition Corrected index 1 A absorptance definition, 78 determinants of, 78 79 energy performance and, 78 tinted glass, 84 acoustical properties of windows, 60 61 acrylic glazing
09990 MOLD REMEDIATION, LEAD-BASED PAINT ABATEMENT AND ENCASEMENT OF ASBESTOS
09990 MOLD REMEDIATION, LEAD-BASED PAINT ABATEMENT AND ENCASEMENT OF ASBESTOS PDS SE-160 01-2006 1. PRODUCT NAME SE-160 Clear Surface Coating (water-based copolymer) Specialty Elastomeric Topcoat 2. MANUFACTURER
Underwriters Laboratories Testing Information
Underwriters Laboratories Testing Information R-8078 Underwriters Laboratories Inc. R-13173 Classified Spray Fiber Surface burning characteristics applied to inorganic reinforced cement board with a maximum
CONDENSATION IN REFRIDGERATED BUILDINGS
CONDENSATION IN REFRIDGERATED BUILDINGS By: Steve Salisbury Nov. 10, 2010 (revised Nov. 14, 2013) Introduction The following discussion reviews the basic causes of condensation in refrigerated buildings
THERMAL INSULATION MATERIALS TEST METHOD SELECTION LIST
THERMAL INSULATION MATERIALS TEST METHOD SELECTION LIST Instruction: Check each test method for which you are requesting accreditation. An asterisk beside the NVLAP Test Method Code indicates that proficiency
DIVISION 23 HEATING, COOLING, AIR CONDITIONING AND VENTILATION
SECTION 230713- ALUMAGUARD ENGINEER SPECIFICATION DIVISION 23 HEATING, COOLING, AIR CONDITIONING AND VENTILATION PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract,
Presented by: Jennifer Doyle, P.E., RRC, LEED AP
Presented by: Jennifer Doyle, P.E., RRC, LEED AP Moisture Gas: Molecules are spread out "Vapor" suspended in air forms a mixture, present everywhere Liquid: Molecules are closer Rain Condensation Pipes
GUIDELINE SPECIFICATIONS
GUIDELINE SPECIFICATIONS GORDON SOFFIT-SHIELD - An Exterior Metal Soffit System DIVISION 05 5800 or DIVISION 07 7700 Note To Specifier: SOFFIT-SHIELD should be installed by tradesmen that are experienced
Article. Protecting the Building Envelope from Water Damage. MemBrain Smart Vapor Retarder & Air Barrier Film
Article Protecting the Building Envelope from Water Damage Vapor Retarders Play a Crucial Role in Moisture Management Whether we like it or not, moisture in the form of water vapor diffusion and humid
SECTION 07 21 16 - PRE-ENGINEERED BUILDING BLANKET INSULATION
PROJECT ARCHITECT RESPONSIBILITY: This is a general specification guide, intended to be used by experienced construction professionals, in conjunction with good construction practice and professional judgment.
Colorado State University. Durrell Center Roof Repair
Colorado State University Durrell Center Roof Repair SPECIFICATION: POLYURETHANE FOAM ROOFING l.0 GENERAL REQUIREMENTS The successful application of a polyurethane foam roofing system is dependent upon
Specifications, Product Testing and Terminology
Specifications, Product Testing and Terminology The following synopsis provides a review of various material and final product testing, which is performed on our products, as well as, many of our competitors.
Enclosures 1-866-338-0988. DuraSystems Barriers, Inc. www.durasystems.com Email: [email protected]. The Passive Fire Protection Specialists
Enclosures Sturdy single and double wall fire protection construction Impact resistant Fast & easy installation Pre-manufactured and modular Available in galvanized, stainless steel & other specialty metals
fire & soundproofing Insulation Roxul Safe n Sound Fire and Soundproofing Insulation for Interior Partition Walls and Floors
fire & soundproofing Insulation Roxul Safe n Sound Fire and Soundproofing Insulation for Interior Partition Walls and Floors Roxul Safe n Sound Sound Control and Fire Safety From One Batt Insulation Roxul
Re-Cover Board-3. Insulation for Above the Deck ROOF WALL SPECIALTY
Insulation for Above the Deck WALL SPECIALTY PRODUCT DESCRIPTION Rmax Re-Cover Board-3 is an energy-efficient thermal insulation board composed of a closed-cell polyisocyanurate (polyiso) foam core bonded
City of Houston Code Enforcement COOL ROOF CODE
City of Houston Code Enforcement COOL ROOF CODE EPA Sustainable Communities Conference Dallas, Texas March 10, 2009 Sheila Blake MBA, CBO, LEED AP Assistant Director, PWE Planning and Development Services
B. ASTM C 533 Calcium Silicate Block and Pipe Thermal Insulation. C. ASTM C 547 Mineral Fiber Preformed Insulation
PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS
EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS 1. SCOPE 1.1 This specification covers the type, physical properties and dimensions of Expanded Polystyrene Insulation Board intended for use
Building Envelope Design by Roxul (BEDR ) FireWall and Roxul Plus MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings
BUILDING ENVELOPE DESIGN BY ROXUL Building Envelope Design by Roxul (BEDR ) FireWall and Roxul Plus MB Fire Rated Board Insulation for Pre-Engineered Metal Buildings ROXUL FIREWALL & ROXUL PLUS MB Exterior
MARTIN TESTING LABORATORIES (MTL) PAINTS AND COATINGS TESTING CAPABILITIES
Liquid Coating Properties Composition VOC Content, ASTM D2369 Water Content, ASTM D4017 Physical Properties Calculating Physical Constants of Coatings, ASTM D5201 Density, ASTM D1475 Flash Point, ASTM
Insulated Roof & Wall Panels. Product Data Sheet. Trapezoidal Insulated Roof Panels KS1000 RW
Insulated Roof & Wall Panels Trapezoidal Insulated Roof Panels KS1000 RW Overview Kingspan roof panel systems present a superior system compared to conventional multi-part site assembled systems. They
Fire & Soundproofing Insulation. Roxul SAFE N SOUND. Fire and Soundproofing Insulation for Interior Partition Walls and Floors.
Fire & Soundproofing Insulation Roxul SAFE N SOUND Fire and Soundproofing Insulation for Interior Partition Walls and Floors. Roxul SAFE N SOUND Sound control and fire safety from one batt Insulation.
1/9/2013. Terminology Calculating Heat Transfer Code Requirements Design Examples and Sustainability
1/9/13 By Brett T. Fagan, P.E. Presented by Marie Horan, P.E. Building Diagnostics, Inc. Building Diagnostics Terminology Calculating Heat Transfer Code Requirements Design Examples and Sustainability
New Cable Tie Type Classifications
1 New Cable Tie Type Classifications UL 62275 United States CSA C22.2 No. 62275 Canada NMX-J-623-ANCE Mexico Technically Equivalent to IEC 62275 All cable ties are not created equal!!! With an increasing
Annex of the certificate (Page 1/6) Accreditation Scope
As a Testing Laboratory Annex of the certificate (Page 1/6) Accreditation Scope Address: Küçük Çiğli Mh. 8780/1 Sk. No:5 Çiğli 35681 İZMİR / TÜRKİYE Phone : 0 232 376 24 25 Fax : 0 232 386 33 98 E-Mail
GigaCrete Specification PlasterMax
GigaCrete Inc. 6775 Speedway Blvd. Suite M105 Las Vegas, NV 89115 Ph (702) 643-6363 Fax (702) 643 1453 www.gigacrete.com GigaCrete Specification PlasterMax PlasterMax : Fire Rated Plaster for Direct Application
Roof Insulation Building. Energy. Environment friendly e-library
Roof Insulation Building Codes & Energy Efficiency Environment friendly e-library Building Code Driver Buildings consumer almost 50% of all energy. Experts believe that a 30% increase in building efficiency
SCENIC VIEW SV 10 SECTION 08 87 13 SOLAR CONTROL FILMS
PART 1 GENERAL SCENIC VIEW SV 10 SECTION 08 87 13 SOLAR CONTROL FILMS 1.1 SUMMARY A. Optically clear dual reflective, neutral sputtered and aluminum metallized polyester film for solar control. 1.2 RELATED
Molds and mildew are fungi that grow
Appendix C: Moisture, Mold and Mildew Molds and mildew are fungi that grow on the surfaces of objects, within pores, and in deteriorated materials. They can cause discoloration and odor problems, deteriorate
Building Envelope Design using ROXUL. FIREWALL and ROXUL PLUS MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings
Building Envelope Design using ROXUL Building Envelope Design using ROXUL (BEDR ) FIREWALL and ROXUL PLUS MB Fire Rated Board Insulation for Pre-Engineered Metal Buildings ROXUL FIREWALL & ROXUL PLUS MB
Comments on How Exterior Paints and Interior Paints Can Play Roles in Conserving Energy. For Tech Traders Inc. By H. F. Poppendiek
Comments on How Exterior Paints and Interior Paints Can Play Roles in Conserving Energy For Tech Traders Inc. By H. F. Poppendiek June 2002 GEOSCIENCE LTD 620 Marindustry Drive San Diego, California 92121
RESNET National Rater Test Study Guide Outline
RESNET National Rater Test Study Guide Outline The RESNET national home energy rating standard spells out a listing of the knowledge base and skills set for Home Energy Ratings. Trainers and Rating Quality
ENGINEERING SPECIFICATION PULTRUDED DYNAFORM FIBERGLASS STRUCTURAL SHAPES. July 1, 2008 Revision 2
ENGINEERING SPECIFICATION PULTRUDED DYNAFORM FIBERGLASS STRUCTURAL SHAPES 1 PART 1 - GENERAL 1.0 GENERAL 1.1 REFERENCES: SECTION 06610 FIBERGLASS REINFORCED PLASTICS (FRP) FABRICATIONS PULTRUDED FIBERGLASS
Requirements for Fire Protection of Light Weight Floor Systems **Act 1 Revisited**
PHRC Webinar Series Tuesday, September 9, 2014 1:00 pm Requirements for Fire Protection of Light Weight Floor Systems **Act 1 Revisited** Presented by: Bryan Heitzmann Credit(s) earned on completion of
DESIGN AND INSTALLATION OF RESIDENTIAL FLEXIBLE DUCTWORK SYSTEMS
DESIGN AND INSTALLATION OF RESIDENTIAL FLEXIBLE DUCTWORK SYSTEMS A. SCOPE 1. This information is intended to assist contractors, installers and code officials in the proper design and installation of flexible
Water Damage & Repair
Water Damage & Repair Chinatown Preservation Talks 2015 James Engler, P.A Glenn Mason, AIA Mason Architects Program Outline Terminology & Waterproofing Basics Discussion of why this is important Below
SECTION 32 1816 PLAYGROUND SURFACING TILES
SECTION 32 1816 PLAYGROUND SURFACING TILES PART 1 GENERAL 1.01 SECTION INCLUDES A. Resilient playground safety surfacing tiles. B. Coordinate with work shown in other sections so the work is installed
Department of Engineering Enzo Ferrari University of Modena and Reggio Emilia
Department of Engineering Enzo Ferrari University of Modena and Reggio Emilia Object: Measurement of solar reflectance, thermal emittance and Solar Reflectance Index Report Reference person: Alberto Muscio
Continuous Insulation Using Polyiso Wall Sheathing
PIMA Technical Bulletin #403 Continuous Insulation Using Polyiso Wall Sheathing What it is, what it does, and why you need it About Polyiso Insulation Polyiso is a rigid foam insulation used in over 70%
Forms of Energy. Freshman Seminar
Forms of Energy Freshman Seminar Energy Energy The ability & capacity to do work Energy can take many different forms Energy can be quantified Law of Conservation of energy In any change from one form
KALPANA INDUSTRIES LTD. TECHNICAL DATA SHEET
1 KALPANA INDUSTRIES LTD. TECHNICAL DATA SHEET KI XL - 03 / KI-SC 10 TWO COMPONENT AMBIENT CURABLE POLYETHYLENE COMPOUND FOR INSULATION OF LOW VOLTAGE POWER CABLE DESCRIPTION : KI polyethylene compound
Building Owners Guide to a Duro-Last System!
Building Owners Guide to a Duro-Last System Table of Contents Section 1: Introduction to Duro-Last Roofing Systems Section 2: Benefits of a Duro-Last Roofing System Section 3: Comparing a Duro-Last Roof
Architectural Testing
FIELD AND MOCK-UP TESTING SERVICES 130 Derry Court York, PA 17406-8405 phone: 717-764-7700 fax: 717-764-4129 www.archtest.com Mock-up Test Methods (Laboratory Mock-up or Field Mock-up): ASTM E 283, Standard
INNOVATIVE. ADAPTABLE. ENERGY EFFICIENT.
INNOVATIVE. ADAPTABLE. ENERGY EFFICIENT. awipanels.com From freezing, sub-zero temperatures to Contents dry heat or high humidity, Mother Nature continually tests the limits of building envelopes. That's
Zero peel strength of acrylic pressure sensitive adhesive is at about 45 C (-50 F).
PRODUCT BULLETIN Aluminum Polyimide Acrylic (3M 966) PSA First Surface Aluminum Coated Polyimide Tape with Acrylic 3M 966 Adhesive TAPES Sheldahl Brand Materials first surface aluminized polyimide tape
CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011
CERTIFICATE NAME OF PRODUCT No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011 H-CONTROL REFLEX+ reflective insulating vapour control layer for roof and wall applications MANUFACTURER ACTIS
- - - - Steel Panel Frame. Exterior Steel Sheeting. Optional Rigid Insulation. Optional Steel Insulation Liner
The Kelly Klosure pre-framed modular panel has 4 components that are factory finished to create an easy and versatile bolt-together system in the field. Steel Panel Frame Exterior Steel Sheeting Optional
Tech Bulletin. Understanding Solar Performance
Tech Bulletin Understanding Solar Performance Bekaert solar control window films use advanced technology to benefit consumers with quality solutions that enhance comfort and decrease energy use. By understanding
POLYURETHANE LINING AND COATING ON PIPE RAW WATER
POLYURETHANE LINING AND COATING ON PIPE RAW WATER PART 1 -- GENERAL 1.1 THE REQUIREMENT A. The CONTRACTOR shall provide pipe coating, complete and in place, in accordance with the Contract Documents. 1.2
CODE NOTES. Insulation Requirements in Commercial Buildings for Mechanical and Service Hot-Water Piping
BUILDING TECHNOLOGIES PROGRAM Insulation Requirements in Commercial Buildings for Mechanical and Service Hot-Water Piping The intent of the pipe insulation requirements is to reduce temperature changes
Green Thread Product Data
Green Thread Product Data Applications Dilute Acids Caustics Produced Water Industrial Waste Hot Water Condensate Return Materials and Construction All pipe manufactured by filament winding process using
The Myth of Vapor Permeation and Thermal Insulation
Whitepaper The Myth of Vapor Permeation and Thermal Insulation Research and Development Department, USLCO US LINER COMPANY ABSTRACT Glass Fiber Reinforced Polypropylene (GFPP) composite is a light weight
keep moisture in check by getting fairly hot and facilitating downward time the sun came out, Then, after installation roof no longer got very
Cool Roofs Cause Condensation Fact or Fiction? by Phil Dregger, PE, RRC, Technical Roof Services, Inc. (Editor s Note: Phil Dregger is a professional engineer, registered roof consultant, author, and fellow
03/05/14 REVISOR RSI/JC RD3945
1.1 Department of Commerce 1.2 Proposed Permanent Rules Relating to Commerce; Thermal Insulation Standards; 1.3 Materials and Installation 1.4 7640.0100 AUTHORITY; PURPOSE; INCORPORATIONS BY REFERENCE.
SECTION 07410 PREFORMED METAL STANDING SEAM ROOFING PART 1 - GENERAL 1.1 DESCRIPTION OF WORK
SECTION 07410 PREFORMED METAL STANDING SEAM ROOFING PART 1 - GENERAL 1.1 DESCRIPTION OF WORK A. This section covers the pre-finished, pre-fabricated Architectural standing seam roof system. All metal trim,
Sun Vinyl New Construction Windows Homeowner's Warranty
Sun Windows Sun Vinyl New Construction Windows Homeowner's Warranty Vinyl Sun Windows, Inc. warrants for a period of 2 years that the quality of workmanship and materials of vinyl items shall be free from
Components HVAC General Standards HVAC Guidelines HVAC System Selection Life Cycle Cost Analysis
Components HVAC General System Selection Life Cycle Cost Analysis Outdoor Air Design Values Indoor Air Design Values Outdoor Air Ventilation Welding Ventilation Temperature Control Systems Ductwork HVAC
Business area System/product family System/product Exterior restore group. Sto restore Advanced Restoration for Building Façades
Business area System/product family System/product Exterior restore group Sto restore Advanced Restoration for Building Façades Sto restore Restoring building exteriors to protect the value of your investment.
Points of Construction
Points of Construction BCB Homes builds the best homes in America. Period. The physics of building in the South Florida hot, humid climate are hard enough on their own, but BCB executes the details better
LEED PRESENTATION OUTLINE
16902 BOLSA CHICA STREET, SUITE 101 HUNTINGTON BEACH, CA 92649 TELEPHONE (714) 840-8230 FACSIMILE (714) 840-2490 LEED PRESENTATION OUTLINE I. Overview of Green Building and Risks Involved with Sustainability
FAST FACTS ADVANTAGES OF MULTI PLY BUILT-UP ROOFING. Asphalt Roofing Manufacturers Association
FAST FACTS ADVANTAGES OF MULTI PLY BUILT-UP ROOFING Roofing Manufacturers Association Why is a built-up roof considered a multi-ply roof? ARMA defines a built-up roofing system as a roof where multiple
Commercial Air Barrier Systems
Commercial Air Barrier Systems Building Envelope Systems Roofing I Air Barriers I Waterproofing The challenge is clear. The importance of air barriers The solution is here. The primary function of a building
September 3, 2009. Ric Boyd, Public Works Director Ketchikan Gateway Borough 344 Front St. Ketchikan, AK 99901
September 3, 2009 Ric Boyd, Public Works Director Ketchikan Gateway Borough 344 Front St. Ketchikan, AK 99901 RE: Ketchikan Gateway Borough Gateway Recreation Center Roof Observations and Intrusive Inspections
8001782 Owner s Manual
8001782 Digital Infrared Thermometer Owner s Manual Introduction This instrument is a portable, easy to use compact-size digital thermometer with laser sighting designed for one hand operation. The meter
What is Solar Control?
A better environment inside and out. Solar, Safety and Security Window Films: Tech Bulletin Understanding Solar Performance Solar Gard solar control window films use advanced technology to benefit consumers
ASTM Volume 04.06, November 2015 Thermal Insulation; Building and Environmental Acoustics
Thermal ; Building and Environmental Acoustics 1 C163-05(2010) Standard Practice for Mixing Thermal Insulating Cement Samples 2 C165-07(2012) Standard Test Method for Measuring Compressive Properties of
Removable Insulation Blankets from A to Z
Removable Insulation Blankets from A to Z At first glance, making up a removable insulation blanket seems somewhat simple take some insulation, put some mesh on one side, a cover on the other, sew them
Evaluating the Field Performance of Windows and Curtain Walls of Large Buildings
Best2 Airtightness of Buildings Session WB6-2 Evaluating the Field Performance of Windows and Curtain Walls of Large Buildings Mario D. Gonçalves, Patenaude-Trempe and Robert Jutras, Air-Ins Introduction
CHAPTER 7: Building Systems ROOFING SYSTEMS
ROOFING SYSTEMS Purpose Examples 1. Shingle roof system 2. Metal roof with blanket insulation 3. Metal roof with rigid insulation 4. Built-up asphalt roof system 5. Single-ply roof system 6. Modified Bitumen
Heating Load Calculation
Heating Load Calculation ME 425 Air Conditioning System Design Keith E. Elder, P.E. Heating Load Calculation The heating load calculation begins with the determination of heat loss through a variety of
National Building Code of Canada 2010
National Building Code of Canada 2010 Emergency Change Issued by the Canadian Commission on Building and Fire Codes The table that follows lists two emergency changes that apply to the National Building
NANSULATE NANOTECHNOLOGY BASED SOLUTIONS TO REDUCE HEAT LOSS THROUGH WINDOWS
NANSULATE NANOTECHNOLOGY BASED SOLUTIONS TO REDUCE HEAT LOSS THROUGH WINDOWS NANSULATE ENERGY PROTECT INSULATION AND PROTECTIVE COATING The science of nanotechnology is behind the innovation of Nansulate
Preventing Ice Dams on Roofs
Preventing Ice Dams on Roofs Facility Manager November/December 2005 When a roof leaks, facility managers inevitably receive complaints from building occupants. If it is winter, ice dams are often the
ENGINEERING SPECIFICATION PULTRUDED DYNARAIL FIBERGLASS LADDER & LADDER CAGES
ENGINEERING SPECIFICATION PULTRUDED DYNARAIL FIBERGLASS LADDER & LADDER CAGES PART 1 - GENERAL 1.1 SCOPE OF WORK SECTION 06610 FIBERGLASS REINFORCED PLASTICS (FRP) FABRICATIONS PULTRUDED SQUARE TUBE LADDER
Product Guide Specification
Reef Industries, Inc. 9209 Almeda Genoa Rd. Houston, Texas 77075 Toll Free (800) 231-6074 Phone (713) 507-4251 Fax (713) 507-4295 Web Site www.reefindustries.com E-Mail [email protected] Product Guide
High Performance PSA in Sheet Membrane in Water Protection
High Performance PSA in Sheet Membrane in Water Protection Xia Cao, Senior R&D Chemist, W. R. Grace, Cambridge MA 02140 Jyoti Seth, Strategic Program Leader, W. R. Grace, Cambridge MA 02140 Concrete is
Solar heat reflective paint & coatings using 3M Glass Bubbles
Solar heat reflective paint & coatings using 3M Glass Bubbles 1- Introduction In most countries, energy use in the building sector represents about one third of the total energy consumption. In developing
NFRC 102-2010 THERMAL PERFORMANCE TEST REPORT. Rendered to: CR LAURENCE CO., INC. SERIES/MODEL: 7500 Concealed Vent TYPE: Projecting (Awning)
NFRC 102-2010 THERMAL PERFORMANCE TEST REPORT Rendered to: CR LAURENCE CO., INC. SERIES/MODEL: 7500 Concealed Vent TYPE: Projecting (Awning) Summary of Results Standardized Thermal Transmittance (U-Factor)
DuPont Kapton HN. polyimide film
DuPont Kapton HN polyimide film Technical Data Sheet DuPont Kapton HN general-purpose film has been used successfully in applications at temperatures as low as -269 C (-452 F) and as high as 400 C (752
INSULATION FOR PRE-ENGINEERED METAL BUILDINGS. ROXUL SAFE 55 & 65 and ROXUL PLUS MB. Insulation for Pre-Engineered Metal Buildings
INSULATION FOR PRE-ENGINEERED METAL BUILDINGS ROXUL SAFE 55 & 65 and ROXUL PLUS MB Insulation for Pre-Engineered Metal Buildings ROXUL SAFE AND ROXUL PLUS MB Exterior Wall Insulation for Pre-Engineered
Attachment #23 Health Safety Table. Client Education Inform issue and document. How to clean & maintain gutters. How to adjust sprinklers
Exterior Visual Health & Safety Issue Allowable Action Site Drainage Exterior grade does not slope 2% within the first 10' Site drainage causing bulk moisture in crawl space or basement Repairs to existing
Renovating Your Basement
building science.com 2006 Building Science Press All rights of reproduction in any form reserved. Renovating Your Building America Report - 0309 2003 (revised 2007) Building Science Corporation Abstract:
Know the Code: Using Spray Foam Insulation In Attics and Crawl Spaces
center for the polyurethanes industry October 2009 Know the Code: Using Spray Foam Insulation In Attics and Crawl Spaces One of the largest growing uses of spray polyurethane foam (SPF) insulation is in
FOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING
FOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING insulation installed on foundation walls must be separated from the building interior with a code approved thermal barrier. Foam
Energy Use in Residential Housing: A Comparison of Insulating Concrete Form and Wood Frame Walls
PCA R&D Serial No. 415 Energy Use in Residential Housing: A Comparison of Insulating Concrete Form and Wood Frame Walls by John Gajda and Martha VanGeem 000 Portland Cement Association KEYWORDS Concrete,
Peel & Seal Self-Stick Roofing Solutions
Peel & Seal Self-Stick Roofing Solutions Ideal for Low Slope Applications Waterproof and Weatherproof Energy Efficient Tough and Durable Versatile, Effective Sealing Around Protrusions Perfect for Vents,
HIGH PERFORMANCE BUILDING ENVELOPES. Dave Seifert
Dave Seifert Design Construction Commissioning PRESENTATION OVERVIEW About BCRA How Did We Get Here? What is a High Performance Building Envelope? Energy Conservation Considerations Durability Considerations
Name: Class: Date: 10. Some substances, when exposed to visible light, absorb more energy as heat than other substances absorb.
Name: Class: Date: ID: A PS Chapter 13 Review Modified True/False Indicate whether the statement is true or false. If false, change the identified word or phrase to make the statement true. 1. In all cooling
