1 Electronic Pressure Measurement Differential Pressure Transmitter Model DPT-10 WIKA Data Sheet PE Applications Process engineering Pharmaceutical Food and beverage industries Special features High measuring accuracy Scaleable measuring ranges Various hazardous area approvals Seven different housing variants Configuration via DTM (Device Type Manager) according to FDT (Field Device Tool) - concept (e.g. PACTware) Bildunterschrift Differential Pressure Transmitter Model DPT-10 Description With its ma, ma HART, PROFIBUS PA or FOUNDATION Fieldbus output signals, combined with either intrinsically-safe or flameproof ignition protection (in accordance with ATEX), the DPT-10 is ideally suited to applications requiring these features. The electronics of all of these transmitters, even for the flameproof variant, are intrinsically safe. Thus it is possible to make adjustments on the instrument in EX areas while the instrument is live. Versatile in application The DPT-10 is suitable for many industrial measuring requirements, such as flow measurement using differential pressure transducers, level measurement or filter and pump monitoring. With diaphragm seals fitted, the DPT-10 is also suitable for harsh process conditions. As a result of the available measuring ranges of mbar up to bar and a static pressure limitation of up to 420 bar, the instrument can be used in almost any application. The internal digital signal processing, combined with proven sensors, guarantees high accuracy and the best long-term stability. There are seven different housing variants available, and thus, it is possible to select a variant suited to every operating environment. The housing itself can be rotated through 330, and is available in plastic, aluminium and stainless steel. An electropolished stainless steel housing (316 L) is available to meet the high demands of the food industry and pharmaceutical industry. Easy configuration and operation Service and configuration at the instrument is carried out using the optional display and operation module, which can be fitted in four positions. The operation menu has a simple and self-explanatory structure and has seven selectable languages as standard. Alternatively, the operating parameters can be set using the PACTware free and non-proprietary configuration software. An instrument-specific DTM enables easy integration into a corresponding Distributed Control Systems. WIKA Data Sheet PE /2010 Page 1 of 8 Data sheets showing similar products and accessories: Process Pressure Transmitter; Model IPT-10, standard version; see Data Sheet PE Process Pressure Transmitter; Model IPT-11, flush diaphragm; see Data Sheet PE 86.11
2 Specifications Model DPT-10 Measuring range 1) bar ) Max. static working pressure bar {420} 160 {420} 160 {420} 160 {420} Smallest possible span mbar Lowest static pressure 3) mbar abs 0.1 Overload on one side bar {420} Overload on both sides bar {630} Accuracy Measuring ranges bar < Long-term stability % URL/Year ± 0.18 ± 0.05 Reference accuracy 4) % of the span Measuring ranges 10, 30 mbar: from TD 1:1 ± 0.15 % x TD up to TD 15:1 TD from 15:1 100 mbar: up to TD 4:1 ± % from TD 4:1 ± (0.012 x TD ) % Total Performance 5) 6) ± 0.15 % ± 0.15 % Influence of the system pressure 6) Zero point % URL ± 0.35 / 70 bar ± / 70 bar Measuring range 10 mbar: 0.15 / 7 bar Span % URL ± 0.14 / 70 bar ± 0.14 / 70 bar Measuring range 10 mbar: / 7 bar Influence of the media and ambient temperature 6) C 10 mbar and 30 mbar ± (0.31 x TD ) % 100 mbar ± (0.18 x TD ) % / C 10 mbar and 30 mbar ± (0.45 x TD + 0.1) % 100 mbar ± (0.3 x TD ) % Mounting position influence mbar bar, 3 bar, 40 bar 16 bar 0.5 bar, 3 bar 16 bar 40 bar ± % ± ( x TD ) % ± (0.08 x TD ) % ± (0.1 x TD + 0.1) % ± (0.12 x TD + 0.1) % ± (0.15 x TD + 0.2) % ± (0.37 x TD + 0.1) % Permitted temperature ranges Ambient 7) C (without Display) (with Display) Transport/Storage Process limits dependent upon the sealing material 7) C FKM/NBR: PTFE, copper: FKM, free of oil and grease: for oxygen applications Copper, PTFE: ; FKM: Temperature limits C With differential pressure lines longer than 100 mm: ( with lateral flanges C22.8) Material Wetted parts Process connection C22.8, {316L, C276} Diaphragm: 316L, C276, {Tantalum, C276 Gold-Rhodium coated, Monel400 } Seals: FKM/FPM, NBR, copper, {PTFE} Internal transmission fluid 8) Silicone oil (halocarbon oil for oxygen applications) Case Plastic (PBT; polyester), {aluminium}, {stainless steel 316L} Weight kg approx depending on the process connection and case version Electrical data Power supply U B V DC non-hazardous: Ex ia: 14 30; Ex d: 20 36; {FOUNDATION fieldbus und PROFIBUS PA Ex ia: Ex d 12 32} Output signal 4 20 ma, 2-wire { ma, 2-wire with a superimposed communication signal HART }, {FOUNDATION Fieldbus }, {PROFIBUS PA} Dead time ms 100 Time constant (63 %) ms 180 (measuring ranges 10, 30 mbar: 250) Damping s 0 999, adjustable Permissible max. load R A in Ω R A = (U B U Bmin ) / A Page 2 of 8 WIKA Data Sheet PE /2010
3 Explosion protection Ex protection 9) ATEX Category II 1G, II 1/2G, II 2G Ex ia IIC T6 T1 II 1/2 G, II 2 G Ex d ia IIC T6 T1 Ambient conditions CE-mark EMC 2004/108/EC interference emission and interference immunity per EN industrial application Interference emission Limit Class A and B, 94/9/EC EN (general part), EN (intrinsic safe), EN (zone 0), {EN (dust Ex)} Shock resistance g 100 per IEC (Shock mechanical) Vibration resistance 10) g 4 (5 100 Hz) (Vibration under resonance) Electrical ingress protection Overvoltage Category III Protection Class II IP66/67 (standard housing) {} Items in curved brackets are optional extras for additional price. 1) Other measuring ranges can be set via the respective Turndown. 2) Measuring range 40 bar, "-" side overload range unilateral up to 100 bar. 3) Valid with reference conditions according to IEC ) Includes non-linearity after limit point setting, hysteresis and non-repeatability in accordance with IEC ) Includes non-linearity, hysteresis, non-repeatability, thermal changes, zero point and static pressure influence (Pstat= 70 bar) in the temperature range C. 6) Values are not valid for tantalum diaphragm. 7) Restrictions of process temperature for oxygen C / the lowest temperature for PN 420: -10 C. 8) Operating pressure with halocarbon oil - higher than 1 bar abs. 9) The operating conditions and safety-relevant data in the approval documents must be read. 10) Tested in accordance with directives, GL characteristic line 2 (not for double chamber cases in stainless steel). URL = basic measuring range TD = Turndown Electrical connection Non-hazardous area Hazardous area Legend: power supply load - supply minus + supply plus 2-wire connection Electrical connection Non-hazardous area Hazardous area PLC Segment coupler Power hub WIKA Data Sheet PE /2010 Page 3 of 8
4 Process connection Oval flange, connection 1/4-18 NPT or RC 1/4 with vent at rear Measuring cells 10 and 30 mbar Measuring cells 100mbar Connection Mounting Material Equipment ¼-18 NPT IEC /16-20 UNF Stainless steel C vent valves 1) ¼-18 NPT IEC /16-20 UNF AISI 316L 2 vent valves 1) ¼-18 NPT IEC /16-20 UNF C276 Without valves / plugs RC ¼ 7/16-20 UNF AISI 316L 2 vent valves 1) ¼-18 NPT IEC PN 160: M10; PN 420: M12 Stainless steel C vent valves 1) ¼-18 NPT IEC PN 160: M10; PN 420: M12 AISI 316L 2 vent valves 1) ¼-18 NPT IEC PN 160: M10; PN 420: M12 C276 Without valves / plugs 1) Material: AISI316L / Oval flange, connection 1/4-18 NPT or RC 1/4, with lateral venting Measuring cells 10 and 30 mbar Measuring cells 100 mbar Connection Mounting Material Equipment ¼-18 NPT IEC /16-20 UNF Stainless steel C vent valves, 4 plug screws 1) ¼-18 NPT IEC /16-20 UNF AISI 316L 2 vent valves, 4 plug screws 1) ¼-18 NPT IEC /16-20 UNF C276 Without valves / plugs RC ¼ 7/16-20 UNF AISI 316L 2 vent valves, 4 plug screws 1) 1) Material: AISI316L / Page 4 of 8 WIKA Data Sheet PE /2010
5 Housing variants Single chamber housing, plastic Single chamber housing, aluminium Single chamber housing, cast stainless steel Single chamber housing, stainless steel, deep-drawn Dual chamber housing, plastic Dual chamber housing, aluminium Dual chamber housing, cast stainless steel WIKA Data Sheet PE /2010 Page 5 of 8
6 Accessories Three-way valve manifolds Five-way valve manifolds With upstream pressure equalising valves it is possible to avoid unilateral overpressure loadings during both start-up and operation as well as enabling zero point checks during operation. Furthermore, they enable the isolation of the process lines without interference to the running process. These pressure equalising valves with integrated shut-off valves, and also purge and ventilating valves, in addition enable the venting of the pressure gauge on one or both sides and enable the supply line to be purged. Diaphragm seals Differential pressure transducer Model DPT-10 differential pressure transmitters can be adapted to the harshest conditions in the process industry by using diaphragm or diaphragm in-line seals. Thus, the transmitters can be used at extreme temperatures, and with aggressive, corrosive, heterogeneous, abrasive, highly viscous or toxic media. As a result of the wide variety of aseptic connections (such as clamp, threaded pipe or DIN aseptic connections) measuring assemblies meet the high demands of sterile process engineering. Differential pressure transducers for flow measurement are available as accessories. Depending on the application, the differential pressure transducers are designed as simple push plugs, measuring flange or complete measuring path. Page 6 of 8 WIKA Data Sheet PE /2010
7 Display and operating module Display and menu item number LC-Display Menu languages: German English French Spanish Polish Italian Dutch Operating keys DTM user interface For HART output signals, Profibus-PA and FF, a DTM is available in accordance with the FDT-standard. The DTM provides a self-explanatory and clear user interface for all setup and control processes of the transmitter. For testing purposes, it is also possible to simulate process values and archive the parameter data. Recording of the measured values is available for diagnostic purposes. Tank volume calculation The additional tank volume calculation of the DTM function can be used to reproduce any optional tank geometry. The corresponding linearisation table is generated automatically. The linearisation table can be transferred directly to the transmitter. WIKA Data Sheet PE /2010 Page 7 of 8
8 Accessories Model Special features Order No. DIH52-F and DIH62-F Indication module DIH52-F and DIH62-F, 5-digit display, 20 segment bargraph, without separate power supply, with additional HART -functionality. Automatic adjustment of measuring range and span. Local-master functionality: Setting the measuring range and unit of the connected transmitters using HART -standard commands. explosion protection according to ATEX. Model HART -Modem for USB-interface, specifically designed for use with modern notebooks Model HART -Modem for RS232-interface Model HART -Modem for Bluetooth-interface [EEx ia] IIC FC475HR1EKL9 FC475HR1EKLU MFC4150 HART protocol, Li-Ion battery, power supply V coloured indication with background lighting, Bluetooth and infrared interface ATEX, FM, CSA and IECEx(i) (including FISCO if available). HART protocol, NIMH battery, power supply AC V, with EASY UPGRADE, ATEX II 2G (1GD) EEx ia IIC T4 HART protocol, universal power supply, cable set with 250 Ω resistance, with DOF upgrade, with Ex-protection DTM Collection incl. PACTware, contains DTMs for WIKA field devices Display and operation module, housing cover in aluminium, with window Display and operation module, housing cover in cast stainless steel, with window Display and operation module, housing cover in plastic, with window Display and operation module, housing cover in stainless steel, electropolished, with window Three-way valve CrNi-steel, PN 420, shape A, Nace compliant, 3.1 material certificate Five-way valve CrNi-steel, PN 420, shape A, Nace compliant, 3.1 material certificate Oval flange 1/4 NPT Cr-Ni-steel CrNi-steel, PN 420, shape A, Nace compliant, 3.1 material certificate Oval flange ½ NPT Cr-Ni-steel CrNi-steel, PN 420, shape A, Nace compliant, 3.1 material certificate Mounting bracket for wall or pipe mounting, stainless steel The specifications given in this document represent the state of engineering at the time of publishing. We reserve the right to make modifications to the specifications and materials. Page 8 of 8 WIKA Data Sheet PE / /2010 GB WIKA Alexander Wiegand SE & Co. KG Alexander-Wiegand-Straße Klingenberg/Germany Tel. (+49) 9372/132-0 Fax (+49) 9372/ info@wika.de
Process pressure transmitter Model IPT-10, standard version Model IPT-11, flush diaphragm
Electronic pressure measurement Process pressure transmitter Model IPT-10, standard version Model IPT-11, flush diaphragm WIKA data sheet PE 86.11 Applications Process engineering Pharmaceutical industry
More informationCompact pressure switch Flameproof enclosure Ex d Model PCA
Mechatronic pressure measurement Compact pressure switch Flameproof enclosure Ex d Model PCA WIKA data sheet PV 33.31 for further approvals see page 4 Process Compact Series Applications Pressure monitoring
More informationPressure transmitter For general industrial applications Model A-10
Electronic pressure measurement Pressure transmitter For general industrial applications Model A-10 WIKA data sheet PE 81.60 for further approvals see page 9 Applications Machine building Shipbuilding
More informationElectronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm
Electronic pressure measurement Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm WIKA data sheet PE 81.67 Applications Machine tools Hydraulics
More informationDigital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version
Electronic pressure measurement Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version WIKA data sheet PE 81.66 Applications Machine building
More informationDMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor
DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO from 0... 00 mbar up to 0... 40 bar Output signals
More informationDiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered
Electrical Temperature Measurement DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered WIKA Data Sheet TE 60.75 Applications Machinery, plant and tank construction
More informationSystem 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter
System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter Application Used to convert a direct-current input signal into a pneumatic output signal for measuring and control
More informationRTX 1000 Series. Versatile Transmitters for a World of Pressure. GE Measurement & Control Solutions. Features
GE Measurement & Control Solutions RTX 1000 Series Versatile Transmitters for a World of Pressure GE Measurement & Control Solutions is renowned for the design and manufacture of compact and rugged high
More informationHow To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)
transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control
More informationThreaded Resistance Thermometers Model TR10-D, Miniature Design
Electrical Temperature Measurement Threaded Resistance Thermometers Model TR10-D, Miniature Design WIKA Data Sheet TE 60.04 Applications Machine building, plant and tank construction Power transmission
More informationTechnical Information RIA14
TI00143R/09/EN/04.14 71256618 Products Solutions Services Technical Information RIA14 Loop powered field indicator With explosion proof enclosure (according to Ex d) Application Oil & gas Petrochemical
More informationBourdon tube pressure gauge with switch contacts Models PGS23.1x0, stainless steel version
Mechatronic pressure measurement Bourdon tube pressure gauge with switch contacts Models PGS23.1x0, stainless steel version k Applications for further approvals see page 14 WIKA data sheet PV 22.02 Control
More informationTEIP11 I/P signal converter for standard signals. Measurement made easy
Data Sheet 10/18-0.11-EN Rev. B TEIP11 I/P signal converter for standard signals Measurement made easy Current in air pressure Proven and reliable concept Compact design Small dimensions, low weight Sturdy
More informationSTX2100. Differential Pressure (Flow) Transmitter. GE Measurement & Control. Models FKC...5. Features
GE Measurement & Control STX2100 Differential Pressure (Flow) Transmitter Models FKC...5 The STX2100 differential pressure (flow) transmitter accurately measures differential pressure, liquid level, gauge
More informationPrecision digital pressure gauge Model CPG1500
Calibration technology Precision digital pressure gauge Model CPG1500 WIKA data sheet CT 10.51 for further approvals see page 4 Applications Oil and gas industry Maintenance and service facilities Calibration
More informationSoftware and Display instruments
Software and Display instruments 272 Overview Software and Display instruments 276 VEGA Inventory System 278 DTM Collection und PACTware 279 VEGACONNECT 280 PLICSCOM, PLICSLED 282 VEGADIS 81, 82, 176 271
More informationPlastic tube flowmeters Series PT/PS
Plastic tube flowmeters Variable area flowmeter for liquids and gases Low cost, excellent readability and light weight Simple installation (flanged, threaded or socket ends for solvent or fusion welding
More informationProduct data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS 40.1001 401001/000-459-405-502-20-601-61
Produktdatenblatt - JUMO MIDAS Pressure Transmitter JUMO AS Street address: Solheimveien 50, 1470 Lørenskog, Norway Phone: +47 67 97 37 10 Delivery address: Solheimveien 50, 1470 Lørenskog, Norway Fax:
More informationDimensions. LUC-M20 with F12 housing and process connection 2" approx. 86 AF60 G2 2 NPT Ø50. Additional dimensions see section dimensions.
Dimensions LUC-M20 with F12 housing and process connection 2" approx. 86 65 78 Ø129 150 AF60 85 G2 2 NPT 22 ~148 Ø50 ~83 Additional dimensions see section dimensions. Features Quick and simple commissioning
More informationOEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250
MAKING MODERN LIVING POSSIBLE Data sheet OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250 The compact OEM pressure transmitter programme is designed for use in severe hydraulic
More informationSITRANS F flowmeters SITRANS F M
Overview Integration The complete flowmeter consists of a flow sensor and an associated transmitter MAG 5000, 6000 or 6000 I. The flexible communication concept USM II simplifies integration and update
More informationDigital inductive conductivity transmitter
Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections
More informationInductive sensor NI10-M18-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M18 x 1 Chrome-plated brass DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) M12
More informationHow To Use A Flowmeter
INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection
More informationSafety instructions VEGAPULS PS62/63/66/67/68.GI/RI(*)****** IECEx BVS 05.0008 Ex t IIIC T Da, Da/Db, Db IP 66
Safety instructions VEGAPULS PS62/63/66/67/68.GI/RI(*)****** IECEx BVS 05.0008 Ex t IIIC T Da, Da/Db, Db IP 66 0044 37321 Contents 1 Area of applicability 4 2 General information 4 2.1 Zone 20 instruments
More informationOnline data sheet PET-1CB010N10SVMC PET PRESSURE SENSORS
Online data sheet PET-1CB010N10SVMC PET B C D E F H I J K L M N O P Q R S T Illustration may differ Detailed technical data Features Pressure type Measuring range Ordering information Other models and
More informationAPT3200 SMART PRESSURE TRANSMITTER. Application Areas: For Gauge And Absolute Pressure Measurement
For Gauge And Absolute Pressure Measurement Application Areas: Nuclear Water & Wastewater Chemicals Petrochemical Oil & Gas Pulp & Paper Food & Beverage, Pharmaceutical Power Renewable Energy Alternate
More informationTEIP11-PS I/P signal converter for standard signals. Measurement made easy
Change from one to tw o c olumns Data Sheet 10/18-0.10-EN Rev. C TEIP11-PS I/P signal converter for standard signals Measurement made easy Proven and reliable concept Compact design Small dimensions, low
More informationRHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits
RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog
More informationwww.suco.de Electronic Pressure Monitoring New Products
Electronic Pressure Monitoring New Products RoHS compliant Electronic Pressure Switches SoS-Technology with one or two switching functions Electronic Pressure Switches CE marking SUCO Electronic pressure
More informationwww.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters
www.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters Description The Tricor Mass Flow Meters measure simultaneously mass
More informationTechnical Data. Dimensions
0102 Model Number Features Comfort series 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories BF 18 Mounting flange, 18 mm EXG-18 Quick mounting bracket with dead stop Technical Data specifications
More informationBypass level indicator With magnetic display Model BNA
Level measurement Bypass level indicator With magnetic display Model BNA WIKA data sheet LM 10.01 Applications Continuous level indication without power supply Indication of the level proportional to height
More informationLevel Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor
Special Features Wetted parts in stainless steel and PEEK Compact design Precise switching point with no requirement for calibration Process temperature 0... 5 C Measures media with DKvalues >.5 (DK =
More information2.12. page 223 2.12. Products for Explosion hazardous Environment
2.12 page 223 2.12 Products for Explosion hazardous Environment Non-electric valves for explosion 2.12.1 page 224 hazardous environment The following manually and mechanically actuated valves are available
More informationkey- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100
Pointek CLS 100 Compact design and short insertion length. Ideal for constricted spaces and for small vessels or pipes up to 100 mm (4 ). Tecum cuil Ludere ipsae. Possem Precision level detection When
More information3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics
3/2-, 5/2-5/3-way Solenoid Valves for process pneumatics Type 6518 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 6518/6519 can be combined with... Stard-,
More informationwww.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter
www.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter Description The coriolis mass flow meters measure simultaneously mass
More informationHand-held thermometer Model CTH7000
Calibration technology Hand-held thermometer Model CTH7000 WIKA data sheet CT 55.50 Applications Precision thermometer for very accurate temperature measurements in a range of -200... +962 C Reference
More informationTechnical data sheet TDS0070
Technical data sheet TDS0070 ATEX Certified II 2 G Ex d IIC T4 Gb IECEx Certified Ex d IIC T4 Gb Ta = -20ºC to +60ºC FEATURES INCLUDE: - ATEX and IECEx Certified explosion proof Exd housing for Premier
More informationFerrostat Speed Sensor Series DSF Explosion Proof Versions EEx
Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx DSF..10.**.HV Ex ATEX Operating Instructions 374E-64368 Valid from lot nr. 0103 General Function Use in potentially explosive environment
More informationMeasurement. SITRANS F US Inline. Transmitter FUS080/FUE080 4/219
Siemens AG 2010 Flow Measurement Overview The transmitter is available in an IP67/NEMA X/6 enclosure and is designed for use in the flowmeters series: SONOKIT (1- or 2-track) FUS380 (2-track) FUE380 (2-track)
More informationTemperature sensor with integrated transmitter for industrial applications, MBT 3560
Temperature sensor with integrated transmitter for industrial applications, MBT 3560 Technical brochure Features Designed for use in harsh industrial enviroments where reliable, robust and accurate equipment
More informationPMP 4000 Series. Druck Amplified Output Pressure Transducers. GE Sensing. Applications. Features
Features Applications The PMP 4000 Series provides a complete range of high level voltage output pressure transducers offering advanced levels of measurement accuracy, stability and flexibility from a
More informationBimetal thermometer Model 52, industrial series
Mechanical temperature measurement Bimetal thermometer Model 52, industrial series WIKA data sheet TM 52.01 for further approvals see page 6 Applications A wide range of applications in machine building,
More informationUNIK 5800/5900. Flameproof/Explosion-Proof Pressure Sensing Platform. GE Measurement & Control. High Quality. Features. Bespoke as Standard.
GE Measurement & Control UNIK 5800/5900 Flameproof/Explosion-Proof Pressure Sensing Platform The 5800 and 5900 are compact and rugged versions of the high performance UNIK 5000 pressure sensing platform
More informationFlow switches Series AD/VH
Flow switches Flow switch and indicator for liquids and gases Suitable for clear, opaque or turbid liquids (series AD & VH), and for gases (series AD) Flow switching by means of magnetic coupling, watertight,
More informationVehicle Brake System Monitoring 2-wire, 4-20 ma option; Intrinsic Safety Approval to E Exia IIC T4 (Tamb=60 C) BASEEFA, CENELEC EN50-020
Field proven rugged construction High overpressure capability High reliability for demanding environments Application specific customization Excellent media compatibility Shock and vibration resistant
More informationRosemount 752 FOUNDATION fieldbus Remote Indicator
Product Data Sheet September 2014 00813-0100-4377, Rev DA Rosemount 752 FOUNDATION fieldbus Remote Indicator Two-wire segment powered device Displays up to eight values Link Master Capability Optional
More informationHow To Make A Smart Transmitter
For Differential/Gauge/Absolute/High Pressure Measurement Application Areas: Nuclear Water & Wastewater Chemicals Petrochemical Oil & Gas Pulp & Paper Food & Beverage, Pharmaceutical Power Renewable Energy
More informationTechnical Data. General specifications Switching element function Rated operating distance s n 15 mm
0102 Model Number Features Comfort series 15 mm flush Accessories MHW 01 Modular mounting bracket MH 04-2057B Mounting aid for VariKont and +U1+ Technical Data General specifications Switching element
More informationMagnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, height 6mm Plastic, PA12 Magnetic-inductive sensor DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6
More informationModel 3051 Pressure Transmitter with HART Protocol
Model 3051 Pressure Transmitter with HART Protocol Start Step 1: Mount the Transmitter Step 2: Consider Housing Rotation Step 3: Set the Jumpers Step 4: Connect the Wiring and Power Up Step 5: Configure
More information2.8. Ex-Recess-mounted, ceiling emergency light fittings in compact metal design
.8 Ex-Recess-mounted, ceiling emergency light fittings in compact metal design RLF/RLF-INOX 50 18-58 W / RLF/RLF-INOX 50... N 18-36 W (Zone 1,, 1, ) The explosion-protected lighting concept for clean rooms
More informationMobrey Ultrasonic. MSP900SH Level and MSP900FH Flow Transmitters. Product Data Sheet February 2015 IP2032, Rev BA
Mobrey Ultrasonic MSP900SH Level and MSP900FH Flow Transmitters Product Data Sheet February 2015 IP2032, Rev BA Non-contacting measurement with no moving parts Fast and simple to install and configure
More informationMicro Motion Model D and DL Coriolis Flow and Density Meters
Product Data Sheet PS-00388, Rev. F April 2013 Micro Motion Model D and DL Coriolis Flow and Density Meters Micro Motion Model D and DL sensors provide flow and density measurement for liquids, gases,
More informationR4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0
FieldBarrier Features Assembly 8... 12 outputs Ex ia IIC, FISCO and Entity Advanced fault isolation and diagnostics at the spur FieldBarrier in Zone 1/Div. 2 Instruments in Zone 0...1/Div. 1 For FOUNDATION
More informationCAPACITIVE LEVEL METERS CLM 36
CAPACITIVE LEVEL METERS CLM 36 For continuous level measurement of liquid and bulk-solid materials Direct mounting into containers, silos, vessels, basins, reservoirs, etc Easy and quick connecting by
More informationAssisted lift operated 2/2-way solenoid valves Type EV250B
MAKING MODERN LIVING POSSIBLE Data sheet Assisted lift operated 2/2-way solenoid valves Type EV250B EV250B with assisted lift can operate from zero and up to 10 bar differential pressure. This 2/2-way
More informationLevel measurement in bulk solids. Capacitive VEGACAL 62 VEGACAL 65 VEGACAL 66 VEGACAL 67. Product Information
Level measurement in bulk solids Capacitive VEGACAL 62 VEGACAL 65 VEGACAL 66 VEGACAL 67 Product Information Content Content Description of the measuring principle...........................................................
More informationMTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter
Thermal Mass meter and Temperature Transmitter Description The MTI10 insertion thermal mass flowmeter and the MTL10 in-line thermal mass flowmeter provide accurate mass flow measurement of clean, dry gases
More informationph/redox Measurement MyPro CPM 431
Technical Information TI 173C/07/en/06.02 50088309 ph/redox Measurement MyPro CPM 431 Two-wire transmitter for ph and redox with Hart and PROFIBUS-PA communication for use in Ex and non-ex areas Application
More informationDifferential-Hall-Effect based Sensors Series A5S
Speed and Frequency Seite 1 von 6 Differential-Hall-Effect based Sensors Series A5S Outstanding Characteristics Speed range covering most demands: from close to zero up to 25,000 pulses/second (response
More informationDREXELBROOK. USonic-R Series. Ultrasonic Level Measurement System. User Friendly
DREXELBROOK A Leader In Level Measurement Solutions USonic-R Series Ultrasonic Level Measurement System User Friendly Set the measurement range directly in inches, feet, millimeters, centimeters, or meters
More informationTechnical Data. Dimensions
0102 Model Number Features 15 mm quasi flush Usable up to SIL2 acc. to IEC 61508 Accessories BF 30 Mounting flange, 30 mm V1-G-N-2M-PUR Female cordset, M12, 2-pin, NAMUR, PUR cable V1-W-N-2M-PUR Female
More informationHLC A1... HLC B1... HLC F1... Data Sheet. Load cells. Special features. B2325-1.0 en
HLC B1... HLC F1... HLC A1... HLC B1... HLC F1... Load cells Special features -- Hermetically sealed (IP68) -- Max. capacities: 220 kg... 10 t -- Stainless steel -- Low overall height -- Meets EMC/ESD
More informationElectro-Magnetic Flowmeters COPA-XT 2-Wire DT43
Data Sheet Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43 2-Wire Operation Significantly reduces installation costs when compared to a traditional 4-wire magmeter. ±0.5% of rate system accuracy. Patented
More informationSEISMIC VELOCITY TRANSDUCER T1-40
SEISMIC VELOCITY TRANSDUCER T1-40 Measurement of Omnidirectional Absolute Vibrations Certified according to ATEX 94/9/CE directive OPERATION Transducer T1-40 serves for seismic measurement of the absolute
More informationCombi switchbox with integrated 3/2 way pilot valve
H Combi switchbox with integrated 3/2 way pilot valve Construction The GEMÜ combi switchbox with integrated 3/2 way pilot valve for pneumatically operated quarter turn actuators has a micro-processor controlled
More informationControl- and feedback head for integrated mounting on Robolux valves Type 2036
Control- and feedback head for integrated mounting on Robolux valves Type 203 Type 885 Type 88 can be combined with Compact stainless steel design Contactless valve position registration Coloured illuminated
More informationRedundancy Module QUINT-DIODE/40
Redundancy Module QUT DIODE provides: 00% decoupling of power supplies connected in parallel Can be installed in potentially explosive areas Load currents up to 60 A supported Easy assembly by snapping
More informationMicrocor Wireless Transmitter (MWT)
Rohrback Cosasco Systems, Inc. Microcor Wireless Transmitter (MWT) Features: Highly Secure and Reliable Self Organizing Wireless Mesh Network High Resolution Metal Loss Measurement for all process environments
More informationModel 266MST Differential Model 266RST Absolute. Measurement made easy. 2600T series pressure transmitters. Engineered solutions for all applications
Data Sheet DS/266MST/RST-EN Rev. D Model 266MST Differential Model 266RST Absolute Measurement made easy 2600T series pressure transmitters Engineered solutions for all applications Base accuracy 0.04
More informationElectronic Pressure Switch EDS 300
Electronic Pressure Switch EDS 300 User manual Page 2 of 16 Content 1. Functions of the EDS 300...3 2. Mounting...3 3. Operating keys on the membrane keypad...4 4. Digital display...4 5. Output function...5
More informationSolenoid Valve Island Type 3965
Solenoid Valve Island Type 365 for the control of pneumatic actuators General The Type 365 Solenoid Valve Island is a compact solution for the centralized control of pneumatic actuators in chemical and
More informationEurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump
Eurovacuum EV Series Single Stage Oil Sealed Rotary Vane Pump Eurovacuum EV Series Single Stage Oil Sealed Rotary Vane Pumps Eurovacuum Company is offering its various products to meet industrial vacuum
More informationTerminal Boxes in Glass Fiber Reinforced Polyester (GRP)
Features Variants options Glass fiber reinforced polyester (GRP) enclosures Suitable for installation in Zones 0, 1, 2, 21 and 22 Certified Ex e, Ex ia and Ex tb 16 enclosure size options Various terminal
More information3DLevelScanner II TECHNICAL DATA SHEET
TECHNICAL DATA SHEET Changing the market from level to volume APM`s 3DLevelScanner incorporates advanced technology for accurately measuring bulk solids and powder stored in silos and open bins of all
More informationDUST EMISSION MONITORING SYSTEM
Applications Measurement of dust concentration in dry or moist, steamsaturated and corrosive stack gases Monitoring of municipal and hazardous waste and sewage sludge incinerators Monitoring of power plants
More informationFluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS
Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS up to size 381; to PN 0.5; to T = 80 C 1. Description 1.1. General FSA fluid level gauges, FSK fluid level sensors and TS temperature
More informationPressure transmitter PASCAL CV
Pressure transmitter PASCAL CV for general applications,type series CV310. Features Modular pressure transmitter with internal or flush mounted diaphragm Output signal: - 4 20 ma - HART protocol (rev.
More informationElectronic Pressure Switch EDS 3000
For Your Information Electronic Pressure Switch EDS 3000 User Manual Revision: November 01, 2002 1. EDS 3000 Functions The EDS 3000 unit offers the following functions: Display pressure in psi, MPa, or
More informationOPTIMASS 6000 Technical Datasheet
OPTIMASS 6000 Technical Datasheet Sensor for mass flow The high performance meter for process industries Cryogenic, high temperature and high pressure options Supreme liquid and gas performance with CT
More informationEuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases
Product information EuroFID Total Hydrocarbon Analyzer Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases Proven Analyzer Technology Measuring total hydrocarbons
More informationPD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description
Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.
More informationAPG. PT-400 Heavy Duty, Amplified Output Pressure Transducer
PT-400 Heavy Duty, Amplified Output Pressure Transducer C US The PT-400 offers high accuracy and reliability over a wide range of pressures. The small size, integrated electronics, wide operating temperature
More informationTechnical Data. General specifications Switching element function Rated operating distance s n 5 mm
0102 Model Number Features 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories EXG-18 Quick mounting bracket with dead stop BF 18 Mounting flange, 18 mm Technical Data specifications Switching
More information3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve
3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve Type 6518 Type 6519 Type 6518/6519 can be combined with... Single or block mounting Suitable for outdoor and chemical atmospheres Suitable for
More informationLinear Luminaire with LED Series EXLUX 6402/2
> Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the
More informationdistributing & controlling system solutions
distributing & controlling system solutions your safety our reality Users > Oil and gas industry production storage transport > Petrochemical industry > Chemical industry > Pharmaceutical industry > Food
More informationHeating, air-conditioning, cooling
Series description Design High efficiency, single stage, low pressure, inline centrifugal pump Supplied with EC motor and electronic duty adaptation Available in glanded construction, mechanical shaft
More informationRetractable Housings. InTrac 781 / 784 Versatile and Rugged For the Toughest Process Conditions INGOLD
INGOLD Leading Process Analytics Retractable Housings InTrac Retractable Sensor Housings for Harsh Applications Wide Range of Options Intelligent Sensor Locking System Highly Efficient Sensor Cleaning
More informationRelative pressure transmitter type 520
Relative pressure transmitter type 520 Pressure range -1... 9 bar / 0... 2.5 1000 bar The compact type 520 pressure transmitter is based upon the Huba Control developed thick film technology where the
More informationRosemount 333 HART Tri-Loop
Product Data Sheet Rosemount 333 Rosemount 333 HART Tri-Loop HART-TO-ANALOG SIGNAL CONVERTER Convert a digital HART signal into three additional analog signals Easy to configure and install Accessory product
More informationBERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features
Booster Pump Control Valve Quick Active Check Valve Isolates system from the effects of pump starts and stops for: Solitary single speed pumps Battery of single speed pumps (add & switch) Battery of variable
More informationData Sheet PS1B Pressure Switch
Data Sheet PS1B Pressure Switch Main Features Pressure Ranges 0 to 6 up to 0 to 600 bar (gage) Electrical Connection G 1/4 A DIN 3852-E or -A Pressure Connection Output Signal M12-4 Pin 4-20 ma, Programmable
More informationSITRANS F flowmeters. SITRANS F M System information SITRANS F M electromagnetic flowmeters. 4/12 Siemens FI 01 2010
Overview are designed for measuring the flow of electrically conductive mediums. The full program consists of three different types of flowmeters making Siemens unique in that it covers all possible applications
More informationOPTIMASS 1400 Technical Datasheet
OPTIMASS 1400 Technical Datasheet Sensor for mass flow First choice for universal applications Best price-performance ratio A wide range of options available with no restrictions The documentation is only
More informationContinuous level. Non-contacting measurement
Continuous level Non-contacting measurement S Y S T E M O V E R V I E W Non-contacting measurement technology by Berthold The level measurement technology by Berthold is used in a variety of industrial
More information