8/23/13 Configuring the Wonderware SECS-II/GEM Host Creator (SERIAL-RS232)
|
|
- Frederick Walters
- 8 years ago
- Views:
Transcription
1 Tech Note 202 Configuring the Wonderware SECS-II/GEM Host Creator (SERIAL- RS232) All Tech Notes and KBCD documents and software are provided "as is" without warranty of any kind. See the Terms of Use for more information. Topic#: Created: December 22, 2000 This Tech Note will show you how to configure the Wonderware SECS-II/GEM Host Creator, and verify the Equipment Creator configuration by configuring an InTouch application. Note In order to verify the Host Creator, you must first configure the Equipment Creator. You must also have a NULL MODEM cable to connect between the HOST Creator and Equipment Creator PC s serial ports. To configure the Equipment Creator, refer to Tech Note 203. Configuring the Wonderware SECS-II/GEM Host Creator 1. Start the Wonderware SECS-II/GEM Host Creator by selecting Program Files\FactorySuite\SECS-II GEM folder. In the SECS-II/GEM Host Creator window, click file and select New Configuration. The Project2 (the name of the configuration in this example) window will appear as shown in Figure 1. FIGURE 1. PROJECT2 WINDOW 2. From the menu bar, click Configure and select Insert Port. Under the Port Type and Number, select SECS-1 and then select the appropriate COM port. In this example, we selected COM 1 as shown in Figure 2. When complete, click OK. 1/11
2 FIGURE 2. DEFINING PORT TYPE AND NUMBER 3. From the menu bar, click Configure and select Insert Tool. Enter a tool name and click OK. In this example we named the tool TestCom1, as shown in Figure 3. FIGURE 3. SPECIFYING A TOOL NAME 4. Expand the TestCom1 tool by clicking the plus sign to the left of the tool. Three options will appear under the tool, as shown in Figure /11
3 FIGURE 4. EXPANDING THE TESTCOM1 TOOL 5. Under the TestCOM1 tool, double-click Communications and select the SECS tab. Set up your com port parameters for the Device ID, Retry Limit and Baud Rate. Click OK. Retain the default timer settings. FIGURE 5. SPECIFYING COM PORT PARAMETERS 6. Under the TestCOM1 tool, double-click Data Item Mappings, select the SVIDs tab and click the 3/11
4 New SVID button. 7. In the Status Variable Properties dialog box, enter the required variables, highlight U2 Unsigned 2-byte integer, under the format section, and click OK. In this example, we used the variables as shown in Figure 6. Note The variable entered for SVID represents the number of SVIDs. An unsigned 1-byte integer would yield a total of 255 SVIDs. FIGURE 6. STATUS VARIABLE PROPERTIES DIALOG BOX 8. Next, in the Select SECS Item Format dialog box, verify the format selected is U2 Unsigned 2- byte integer and click OK. FIGURE 7. VERIFYING SVID FORMAT 9. You will be returned to the Data Items Mapping dialog box. Under the Status Variable List Varieants section click the New List button. 10. In the New List Variant dialog box, for the List Name enter taglist. Under Items Available, highlight tag1 and click the Add button, as shown in Figure 8. The item, tag1, should then appear under the Items in List. 4/11
5 FIGURE 8. NEW LIST VARIANT DIALOG BOX 11. You will be returned to the Data Items Mapping dialog box, click the Apply button and then click OK. 5/11
6 FIGURE 9. DATA ITEM MAPPINGS DIALOG BOX 12. From the SECS-II/GEM Host Creator window, select File/Save Configuration. Enter a file name and click the Save button. In this example, we used Project6 for the file name. FIGURE 10. SAVING THE CONFIGURATION Verifying the Host Creator Configuration 6/11
7 Creating an InTouch Application 1. In WindowMaker, create a new window. From the menu bar, select Special, click on Configure and then click on Wizard/ActiveX Installation, as shown in Figure 11. FIGURE 11. WINDOWMAKER WINDOW 2. In the Wizard/ActiveX Installation dialog box, click the ActiveX Control Installation tab. Under the Available ActiveX controls section, highlight Wonderware SECS-II/GEM Host Runtime and click the Install button. 3. When complete, the Wonderware SECS-II/GEM Host Runtime will appear under the Installed ActiveX controls section, as shown in Figure 12. Click the Close button. 7/11
8 FIGURE 12. INSTALLING ACTIVEX CONTROLS 4. In WindowMaker, click the Wizard hat and highlight ActiveX Controls. The SECSHost wizard should appear. Select the SECSHostl and drop it on the newly created window, as shown in Figure /11
9 FIGURE 13. WIZARD SELECTION DIALOG BOX 5. Next, add three buttons and one analog display. Label the buttons as shown is Figure 14. FIGURE 14. ADDING AND DEFINING BUTTONS 6. To activate the Traffic TraceLevel, double-click the SECSHost. Click the Properties tab and under the Property section find Traffic TraceLevel and enter Traffic as the Associated Tag. 9/11
10 FIGURE 15. ADDING THE ASSOCIATED TAG 7. Next, using the following script, create an action pushbutton associated with the load tool button. < #SecsHost1.LoadSECSEngine("TestCOM1",1);> 8. Using the following tag, create a discrete value pushbutton (use the toggle option) associated with the Traffic Trace button. < Traffic > <Define the traffic tag as a memory discrete> 9. Using the following script, create an action bushbutton associated with the Get Value button. <#SecsHost1.DoSECSMessageEx (1, 3, "taglist");> 10. Create a memory integer tag called tag Next, create an application script similar to the following: <tag1=$second;> while running, every 1000ms. 12. When complete, create an analog display with a value of tag In runtime, click the Load Tool, Traffic Trace, and the Get Value buttons. Note Each time you click the Get Value button, the item tag1 should match-up with tag1 on the equipement side. 14. The following Wonderware Logger window shows an example of the equipment successfully communicating with the HOST. 10/11
11 FIGURE 16. EQUIPMENT SUCCESSFULLY COMMUNICATING WITH THE HOST D. Plesset The Tech Note is published occasionally by Wonderware Technical Support. Editors: Sabrina Abercromby and Kelly Hauser; Publisher: Wonderware Corporation, 100 Technology Drive, Irvine CA There is also technical information on our software products at Wonderware Technical Support, our WonderFax fax-on-demand system at (949) , and the Comprehensive Support Knowledge Base. For technical support questions, send an to back to top 2013 Wonderware Corporation. All rights reserved. Terms of Use. 11/11
Tech Note 53 Configuring the Siemens SINEC H1 CP1413 for Windows NT
Tech Note 53 Configuring the Siemens SINEC H1 CP1413 for Windows NT All Tech Notes and KBCD documents and software are provided "as is" without warranty of any kind. See the Terms of Use for more information.
More informationInstalling the TCP/IP Network Protocol
Tech Note 120 Configuring the GEHCS I/O Server for Windows NT All Tech Notes and KBCD documents and software are provided "as is" without warranty of any kind. See the Terms of Use for more information.
More informationAll Tech Notes and KBCD documents and software are provided "as is" without warranty of any kind. See the Terms of Use for more information.
Tech Note 115 Overview of the InTouch 7.0 Windows NT Services All Tech Notes and KBCD documents and software are provided "as is" without warranty of any kind. See the Terms of Use for more information.
More information8/23/13 Configuring the S7 I/O Server for Windows 95 to Access S7 PLCs Via the Profibus Network
Tech Note 110 Configuring the S7 I/O Server for Windows 95 to Access S7 PLCs Via the Profibus Network All Tech Notes and KBCD documents and software are provided "as is" without warranty of any kind. See
More informationTech Note 128 Configuring InBatch For Standalone PCs With SQL Server and IndustrialSQL Server
Tech Note 128 Configuring InBatch For Standalone PCs With SQL Server and IndustrialSQL Server All Tech Notes and KBCD documents and software are provided "as is" without warranty of any kind. See the Terms
More informationTech Note 400 Configuring Remote Connections for Windows 2000/2003/XP
Tech Note 400 Configuring Remote Connections for Windows 2000/2003/XP All Tech Notes and KBCD documents and software are provided "as is" without warranty of any kind. See the Terms of Use for more information.
More informationInstalling An ActiveX Control in InTouch
Tech Note 117 Using the InTouch 7.0 ActiveX Container All Tech Notes and KBCD documents and software are provided "as is" without warranty of any kind. See the Terms of Use for more information. Topic#:
More informationTech Note 213 Finding Memory Leaks in Windows 95/98/98SE Using System Monitor
Tech Note 213 Finding Memory Leaks in Windows 95/98/98SE Using System Monitor All Tech Notes and KBCD documents and software are provided "as is" without warranty of any kind. See the Terms of Use for
More informationAll Tech Notes and KBCD documents and software are provided "as is" without warranty of any kind. See the Terms of Use for more information.
Tech Note 365 Working with InTouch I/O Tags in InControl All Tech Notes and KBCD documents and software are provided "as is" without warranty of any kind. See the Terms of Use for more information. Topic#:
More informationPart I: Setting up Bristol Babcock's OPC Server
Tech Note 274 Setting up Bristol Babcock's OPC Server to Communicate with OPCLink All Tech Notes and KBCD documents and software are provided "as is" without warranty of any kind. See the Terms of Use
More informationIntroduction. Symbol Script Timeout Setting. Sample MES Custom Code in Symbol Script. Application Versions. Sample Code
Tech Note 1006 Managing Symbol Script Timeouts When Using WW MES API Pop-up Dialogs All Tech Notes, Tech Alerts and KBCD documents and software are provided "as is" without warranty of any kind. See the
More informationTech Note 663 HMI Reports: Creating Alarm Database (WWALMDB) Reports
Tech Note 663 HMI Reports: Creating Alarm Database (WWALMDB) Reports All Tech Notes, Tech Alerts and KBCD documents and software are provided "as is" without warranty of any kind. See the Terms of Use
More informationIntroduction. Notes. Important Considerations. Application Versions. Assumptions. 8/22/13 Setting Up Historian Servers for Tier-2 Summary Replication
Tech Note 884 Setting Up Historian Servers for Tier-2 Summary Replication All Tech Notes, Tech Alerts and KBCD documents and software are provided "as is" without warranty of any kind. See the Terms of
More informationAll Tech Notes and KBCD documents and software are provided "as is" without warranty of any kind. See the Terms of Use for more information.
Tech Note 461 Troubleshooting Industrial Application Server Bootstrap Communications All Tech Notes and KBCD documents and software are provided "as is" without warranty of any kind. See the Terms of Use
More informationNote: This Tech Note was formerly titled Installing Microsoft SQL Server 2008 for Wonderware Historian v10.0.
Tech Note 682 Installing Microsoft SQL Server 2008 for Wonderware Products All Tech Notes, Tech Alerts and KBCD documents and software are provided "as is" without warranty of any kind. See the Terms of
More informationUSER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: 2900-300321 Rev 6
KRAMER ELECTRONICS LTD. USER GUIDE Ethernet Configuration Guide (Lantronix) P/N: 2900-300321 Rev 6 Contents 1 Connecting to the Kramer Device via the Ethernet Port 1 1.1 Connecting the Ethernet Port Directly
More informationIntroduction. Application Versions. Installing Virtual SMTP Server. Tech Note 692 Using Virtual SMTP Server for SCADAlarm Email Notifications
Tech Note 692 Using Virtual SMTP Server for SCADAlarm Email Notifications All Tech Notes, Tech Alerts and KBCD documents and software are provided "as is" without warranty of any kind. See the Terms of
More informationThis Tech Note provides step-by-step procedures to install Microsoft SQL Server 2012 on a 32- or 64-bit Operating System.
Tech Note 958 Installing Microsoft SQL Server 2012 for Wonderware Products All Tech Notes, Tech Alerts and KBCD documents and software are provided "as is" without warranty of any kind. See the Terms of
More informationInstalling the Gerber P2C Plotter USB Driver
Installing the Gerber P2C Plotter USB Driver 1 You can install a Gerber P2C plotter using a USB connection and communicate with it using compatible design software. The following procedures describe installing
More informationSECURITY SYSTEM MANAGEMENT SOFTWARE FOR WINDOWS. Quick Start Instructions
TM SECURITY SYSTEM MANAGEMENT SOFTWARE FOR WINDOWS Quick Start Instructions Introduction WinLoad for Windows was developed to simplify and speed up the task of programming Paradox control panels. Remote
More informationIntroduction. Tech Note 884 Setting Up Historian Servers for Tier-2 Summary Replication
Tech Note 884 Setting Up Historian Servers for Tier-2 Summary Replication All Tech Notes, Tech Alerts and KBCD documents and software are provided "as is" without warranty of any kind. See the Terms of
More informationTech Note 338 How to Change the ActiveFactory Reporting Website Default Install Location
Tech Note 338 How to Change the ActiveFactory Reporting Website Default Install Location All Tech Notes and KBCD documents and software are provided "as is" without warranty of any kind. See the Terms
More informationAlarm Display. Tips & Tricks DIANA SMIT. Tel: 0861-WONDER Fax: (011) 607-8478
Ground floor Block D Gillooly s View Office Park 1 Osborne Road Bedfordview Tel: 0861-WONDER Fax: (011) 607-8478 Alarm Display Tips & Tricks DIANA SMIT Table of Contents 1. Introduction... 3 2. Creating
More informationTech Note 882 Configuring Time Synchronization for Historian Server Using Net Time and Windows Task Scheduler
Tech Note 882 Configuring Time Synchronization for Historian Server Using Net Time and Windows Task Scheduler All Tech Notes, Tech Alerts and KBCD documents and software are provided "as is" without warranty
More informationIntroduction. Application Versions. Assumptions. Delete $$ExportTempFolders. Tech Note 930 Wonderware System Platform Clean-up Guide
Tech Note 930 Wonderware System Platform Clean-up Guide All Tech Notes, Tech Alerts and KBCD documents and software are provided "as is" without warranty of any kind. See the Terms of Use for more information.
More informationTech Note 782 Installing Remote Desktop Services on Windows 2008 Server R2 for Wonderware Products
Tech Note 782 Installing Remote Desktop Services on Windows 2008 Server R2 for Wonderware Products All Tech Notes, Tech Alerts and KBCD documents and software are provided "as is" without warranty of any
More informationUsing Network Application Development (NAD) with InTouch
Tech Note 256 Using Network Application Development (NAD) with InTouch All Tech Notes and KBCD documents and software are provided "as is" without warranty of any kind. See the Terms of Use for more information.
More informationTech Note 743 Configuring Reporting Services 2008 Configuration for a New Host Name in Windows 2008 R2
Tech Note 743 Configuring Reporting Services 2008 Configuration for a New Host Name in Windows 2008 R2 All Tech Notes, Tech Alerts and KBCD documents and software are provided "as is" without warranty
More informationTech Note 652 Changing an ArchestrA Symbol's Custom Property Expression or Reference in Runtime
Tech Note 652 Changing an ArchestrA Symbol's Custom Property Expression or Reference in Runtime All Tech Notes, Tech Alerts and KBCD documents and software are provided "as is" without warranty of any
More informationScanWin Installation and Windows 7-64 bit operating system
ScanWin Installation and Windows 7-64 bit operating system In order to run the ScanWin Pro install and program on Windows 7 64 bit operating system you need to install a Virtual PC and then install a valid,
More informationeadvantage Certificate Enrollment Procedures
eadvantage Certificate Enrollment Procedures Purpose: Instructions for members to obtain a digital certificate which is a requirement to conduct financial transactions with the Federal Home Loan Bank of
More informationConnecting and Setting Up Your Laptop Computer
CHAPTER 3 Connecting and Setting Up Your Laptop Computer This chapter explains how to connect your laptop to the Cisco Unified MeetingPlace system and how to set up your laptop so that you can use HyperTerminal.
More informationTech Note 882 Configuring Time Synchronization for Historian Server Using Net Time and Windows Task Scheduler
Tech Note 882 Configuring Time Synchronization for Historian Server Using Net Time and Windows Task Scheduler All Tech Notes, Tech Alerts and KBCD documents and software are provided "as is" without warranty
More informationTable of Contents Install a Printer Driver... 2 Print a Test Label... 9 Uninstall a Printer and Driver... 10
Table of Contents Install a Printer Driver... 2 Print a Test Label... 9 Uninstall a Printer and Driver... 10 Copyright 2016, United Parcel Service of America, Inc. All rights reserved. 1 Install a Printer
More informationLPR for Windows 95/98/Me/2000/XP TCP/IP Printing User s Guide. Rev. 03 (November, 2001)
LPR for Windows 95/98/Me/2000/XP TCP/IP Printing User s Guide Rev. 03 (November, 2001) Copyright Statement Trademarks Copyright 1997 No part of this publication may be reproduced in any form or by any
More informationWindows 95 Revision B Installation Instructions
Windows 95 Revision B Installation Instructions Follow the instructions in this document if you are installing Live200 1.5 on a PC that runs Windows 95 revision B (OSR2). The Windows 95 version number
More informationEthernet Interface Manual Thermal / Label Printer. Rev. 1.01 Metapace T-1. Metapace T-2 Metapace L-1 Metapace L-2
Ethernet Interface Manual Thermal / Label Printer Rev. 1.01 Metapace T-1 Metapace T-2 Metapace L-1 Metapace L-2 Table of contents 1. Interface setting Guiding...3 2. Manual Information...4 3. Interface
More informationBasic Use of the SPC Feature on 1100R+/H+ Testers
Basic Use of the SPC Feature on 1100R+/H+ Testers Basics 1100 SPC Data (Note: SPC data collection is an optional feature only available on 1100R+/H+ testers that are equipped with USB ports For the feature
More informationJolly Server Getting Started Guide
JOLLY TECHNOLOGIES Jolly Server Getting Started Guide The purpose of this guide is to document the creation of a new Jolly Server in Microsoft SQL Server and how to connect to it using Jolly software products.
More informationLPR for Windows 95 TCP/IP Printing User s Guide
LPR for Windows 95 TCP/IP Printing User s Guide First Edition Printed in Taiwan, R.O.C. RECYCLABLE Copyright Statement Trademarks Limited Warranty Copyright 1997 D-Link Corporation No part of this publication
More informationUsing HyperTerminal with Agilent General Purpose Instruments
Using HyperTerminal with Agilent General Purpose Instruments Windows HyperTerminal can be used to program most General Purpose Instruments (not the 531xx series counters) using the RS-232 Serial Bus. Instrument
More informationTSX ETZ Configuration of your computer for TSX ETZ direct connection by serial link. Eng V1.0
TSX ETZ Configuration of your computer for TSX ETZ direct connection by serial link Eng V1.0 2 Table of Contents About the book.......................................5 Chapter 1 Configuration and connection
More informationSAPIP GUI INSTALLATION. Table of Contents
QUICK START GUIDE SAPIP GUI INSTALLATION Table of Contents 1. Install CSU cable driver for SapIP..2-3 2. Check for pre-requisite for SAPIP GUI install......2 3. Check for pre-requisite for SAPIP GUI install...2-6
More informationDP-313 Wireless Print Server
DP-313 Wireless Print Server Quick Installation Guide TCP/IP Printing (LPR for Windows 95/98/Me/2000) Rev. 03 (August, 2001) Copyright Statement Trademarks Copyright 1997 No part of this publication may
More informationAll Tech Notes and KBCD documents and software are provided "as is" without warranty of any kind. See the Terms of Use for more information.
Tech Note 211 Configuring Microsoft FrontPage Server Extensions All Tech Notes and KBCD documents and software are provided "as is" without warranty of any kind. See the Terms of Use for more information.
More information3. USB DRIVER. 3-1. Installation of USB driver. 3-1-1. Driver for Infinity SD Data Logger. INFINITY Series Acquisition Tools Manual
3. USB DRIVER 3-1. Installation of USB driver Before you launch this software, the driver should be once surely registered. Access between the instrument and a PC through the USB cable supplied by us as
More informationIntroduction. Back Up the Runtime Database. Application Versions
Tech Note 1035 Moving the Historian Runtime Database to Another Machine Using SQL Server 2012 All Tech Notes, Tech Alerts and KBCD documents and software are provided "as is" without warranty of any kind.
More informationHow To Connect A Directsofl To A Powerpoint With An Acd With An Ctel With An Dm-Tel Modem On A Pc Or Ipad Or Ipa (Powerpoint) With A Powerline 2 (Powerline
Application Note Last reviewed: 03/17/2008 AN-KEP-003.doc Page 1 of 23 Introduction... 1 Recommended s and ports to use... 1 Cable Wiring... 2 MDM-TEL Configuration ( Wizard)... 3 Direct Logic Communications
More informationMetasys System Direct Connection and Dial-Up Connection Application Note
Metasys System Direct Connection and Dial-Up Connection Application Note Code No. LIT-1201639 Software Release 5.1 Issued August 27, 2013 Supersedes October 4 2010 Refer to the QuickLIT website for the
More informationThis tech note will explain how to use the following parameters in Configurator General Parameters.
Tech Note 707 Configuring Allowable Deviation in Operations and Performance All Tech Notes, Tech Alerts and KBCD documents and software are provided "as is" without warranty of any kind. See the Terms
More informationCommunication to End Device Going In and Out of Slow Poll Mode
Tech Note 693 Using DASMBTCP to Solve Third-Party Modbus Device Communication Problems All Tech Notes, Tech Alerts and KBCD documents and software are provided "as is" without warranty of any kind. See
More informationKepware Technologies KEPServerEX Client Connectivity Guide for GE's Proficy ifix
Kepware Technologies KEPServerEX Client Connectivity Guide for October, 2011 V. 1.105 Kepware Technologies Table of Contents 1. Overview and Requirements... 1 1.1 Installing KEPServerEX... 1 2. Preparing
More informationGlobal Water Instrumentation, Inc.
Global Water Instrumentation, Inc. 151 Graham Road P.O. Box 9010 College Station, TX 77842-9010 Telephone : 800-876-1172 International : (979) 690-5560, Fax : (979) 690-0440 e-mail : globalw@globalw.com
More information8/23/13 Configuring the S7 Server for Windows NT 4.0 to Access S7-400 PLCs via the Siemens CP1613 Card for ISO (Industrial Ethernet)
Tech Note 224 Configuring the S7 Server for Windows NT 4.0 to Access S7-400 PLCs via the Siemens CP1613 Card for ISO (Industrial Ethernet) All Tech Notes and KBCD documents and software are provided "as
More informationHP-1000 Powerline Ethernet Adapter
HP-1000 Powerline Ethernet Adapter User s manual BEFORE INSTALLATION Plan ahead the installation of your powerline network. Note: You will need at least two powerline adapters to create a powerline network.
More informationHP-1000 Powerline USB Adapter
HP-1000 Powerline USB Adapter User s manual BEFORE INSTALLATION Plan ahead the installation of your powerline network. Note: You will need at least two powerline adapters to create a powerline network.
More informationConfiguring the SST DeviceNet OPC Server
Overview This application note describes the steps necessary to configure the SST DeviceNet OPC Server for use under Windows NT (Service Pack 3 or higher). This example shows how to set up a configuration
More informationHow to configure the DBxtra Report Web Service on IIS (Internet Information Server)
How to configure the DBxtra Report Web Service on IIS (Internet Information Server) Table of Contents Install the DBxtra Report Web Service automatically... 2 Access the Report Web Service... 4 Verify
More informationQUICK START GUIDE. SG2 Client - Programming Software SG2 Series Programmable Logic Relay
QUICK START GUIDE SG2 Client - Programming Software SG2 Series Programmable Logic Relay SG2 Client Programming Software T he SG2 Client software is the program editor for the SG2 Series Programmable Logic
More informationRemote Access for Cisco Unity 8.x
CHAPTER 9 Remote Access for Cisco Unity 8.x Accessing Cisco Unity 8.x Remotely There are several methods that allow remote access to the Cisco Unity server so that you can do tasks such as loading updates
More informationHow To Write A Summary On A Historyorian Server
Tech Note 869 Configuring Historian Server for Local Data Summarization All Tech Notes, Tech Alerts and KBCD documents and software are provided "as is" without warranty of any kind. See the Terms of Use
More informationUSB Driver Installation for Windows XP
USB Driver Installation for Windows XP USB Serial Converter Driver Installation for Windows XP CAUTION: You must use the drivers on the CD-ROM supplied with your USB Device. DO NOT download drivers from
More informationExport the address book from the Blackberry handheld to MS Outlook 2003, using the synchronize utility in Blackberry Desktop Manager.
Export the address book from the Blackberry handheld to MS Outlook 2003, using the synchronize utility in Blackberry Desktop Manager. Revised 2/25/07 Creating a New Contacts Folder in Outlook Open Outlook
More informationEmail Account Create for Outlook Express
Email Account Create for Outlook Express Click Start Menu Choose Outlook Express Click Tools menu from Menu Bar and then click Accounts In Internet Account Wizard, Click Add Button and Click Mail. 1 In
More information1. Open Thunderbird. If the Import Wizard window opens, select Don t import anything and click Next and go to step 3.
Thunderbird The changes that need to be made in the email programs will be the following: Incoming mail server: newmail.one-eleven.net Outgoing mail server (SMTP): newmail.one-eleven.net You will also
More informationWhile every effort was made to verify the following information, no warranty of accuracy or usability is expressed or implied.
AG090710 Siemens HART or PROFIBUS Instruments and FDT ( Field Device Tool ) Connecting Siemens HART or PROFIBUS instruments to FDT using SITRANS DTM and a communication interface Objective: Equipment:
More informationInTouch Example Description
InTouch Example Description This document describes how to work with the InTouch example. It contains the following sections: Using the LNS DDE Server Examples 2 Using the Example LNS Database 2 Sequence
More informationKepware Technologies KEPServerEX Client Connectivity Guide for Wonderware InTouch
Kepware Technologies KEPServerEX Client Connectivity Guide for October, 2011 Version 1.002 Kepware Technologies Table of Contents 1. Overview... 1 1.1 Installing Common Components... 1 1.2 Installing KEPServerEX...
More informationUSER GUIDE FOR DIGITAL CERTIFICATE
USER GUIDE FOR DIGITAL CERTIFICATE If you encounter any problem and no solution can be obtained from the USER GUIDE FOR DIGITAL CERTIFICATE, please contact our hotline at 03-8992 8888 or customercare@digicert.com.my
More informationUDS2100 Quick Start Guide
Quick Start Guide 2008 Copyright Lantronix is a trademark of Lantronix. All rights reserved. 900-447 Rev. B 7/08 QUICK START CONTENTS What s In the Box..........................................................2
More informationFC5A Modbus Communication Training
FC5A Modbus Communication Training Table of Contents 1 System Setup... 3 1.1 1:1 Network... 3 1.2 1:N Network (Up to 31 Slaves)... 3 2 Modbus Communication Examples... 4 2.1 Example 1 - Reading 1 word
More informationCrystal Print Control Installation Instructions for PCs running Microsoft Windows XP and using the Internet Explorer browser
Crystal Print Control Installation Instructions for PCs running Microsoft Windows XP and using the Internet Explorer browser Important Notice: You must have administrative rights to your PC to perform
More informationMT-350 SMS. Operation Manual. PORTech Communications Inc.
MT-350 SMS Operation Manual PORTech Communications Inc. Index 1.Hardware Setup...1 2.Software Setup...1 3.Operation Guide...2 4.How to send out a short message...3 5.Report File...6 6.Q & A...6 MT-350
More information8/22/13 Configuring the SST5136SD PCI Card Using the New SSTDHP IO Server V8.1 or the DASDHPlus Server
Tech Note 448 Configuring the SST5136SD PCI Card Using the New SSTDHP I/O Server or the DASDHPlus Server All Tech Notes and KBCD documents and software are provided "as is" without warranty of any kind.
More information1. Under Application Objects, open the $Tank object and then open the $TankDisplay as shown in Figure 1 (below).
Tech Note 596 Using the OwningObject Property with ArchestrA Graphics All Tech Notes, Tech Alerts and KBCD documents and software are provided "as is" without warranty of any kind. See the Terms of Use
More informationFLASH PROCEDURE for GSM BENTEL and DSC cards
FLASH PROCEDURE for GSM BENTEL and DSC cards Following step are intended to properly update the flash memory of the GSM card. The same procedure will guide you to recover a GSM card after a block due to
More informationProfessional USB to Serial Adapter Hub with COM Retention
Professional USB to Serial Adapter Hub with COM Retention ICUSB2321X ICUSB2322X ICUSB2324X *actual product may vary from photos *actual product may vary from photos DE: Bedienungsanleitung - de.startech.com
More informationReadMe File. Installing the Unified Messaging Application for
ReadMe File MERLIN! Messaging System Release 4.0 and PARTNER! Messaging System Release 7.0 Installing the Unified Messaging Application 11-300139, Issue 2, May 2004 ReadMe File Installing the Unified Messaging
More informationTechnical Note. Setting ACS drive IP address automatically with Rockwell BOOTP/DHCP Server. Contents
Setting ACS drive IP address automatically with Rockwell BOOTP/DHCP Server Contents System Requirements...2 Software...2 Cabling...2 1.0 Introduction...3 2.0 ACS / TMI Setup...3 3.0 Rockwell BOOTP/DHCP
More informationAll Tech Notes and KBCD documents and software are provided "as is" without warranty of any kind. See the Terms of Use for more information.
Tech Note 426 Panel PC Performance Testing and Results All Tech Notes and KBCD documents and software are provided "as is" without warranty of any kind. See the Terms of Use for more information. Topic#:
More informationIntroduction. Issues. Symptoms. Application Versions. Case 1: Deploy an ArchestrA Object - UDO4DevUsers_001_001 - Has Error Messages
Tech Note 998 Wonderware Application Server Security Troubleshooting Essentials Part 1: Galaxy Security - Runtime Errors and Security Groups Settings All Tech Notes, Tech Alerts and KBCD documents and
More informationTech Note 1035 Moving the Historian Runtime Database to Another Machine Using SQL Server 2012
Tech Note 1035 Moving the Historian Runtime Database to Another Machine Using SQL Server 2012 All Tech Notes, Tech Alerts and KBCD documents and software are provided "as is" without warranty of any kind.
More informationApplication Note: Connecting to a 2500 Series Processor using PLC Workshop
Application Note: Connecting to a 2500 Series Processor using PLC Workshop This application note will describe a step by step process for the three ways to connect to a 2500-CXXX with PLC Workshop. The
More informationTech Note 782 Installing Remote Desktop Services on Windows 2008 Server R2 for Wonderware Products
Tech Note 782 Installing Remote Desktop Services on Windows 2008 Server R2 for Wonderware Products All Tech Notes, Tech Alerts and KBCD documents and software are provided "as is" without warranty of any
More informationTech Note 847 Installing Wonderware Information Server (WIS) on the Windows Server Window 7 64 and 32-bit Operating System
Tech Note 847 Installing Wonderware Information Server (WIS) on the Windows Server Window 7 64 and 32-bit Operating System All Tech Notes, Tech Alerts and KBCD documents and software are provided "as is"
More informationTSM for Windows Installation Instructions: Download the latest TSM Client Using the following link:
TSM for Windows Installation Instructions: Download the latest TSM Client Using the following link: ftp://ftp.software.ibm.com/storage/tivoli-storagemanagement/maintenance/client/v6r2/windows/x32/v623/
More informationTech Note 920 Resolving Disabled ActiveFactory Reporting Website for Wonderware System Platform R2
Tech Note 920 Resolving Disabled ActiveFactory Reporting Website for Wonderware System Platform R2 All Tech Notes, Tech Alerts and KBCD documents and software are provided "as is" without warranty of any
More informationSage HRMS 2014 Sage Employee Self Service Tech Installation Guide for Windows 2003, 2008, and 2012. October 2013
Sage HRMS 2014 Sage Employee Self Service Tech Installation Guide for Windows 2003, 2008, and 2012 October 2013 This is a publication of Sage Software, Inc. Document version: October 17, 2013 Copyright
More informationGuide to Installing BBL Crystal MIND on Windows 7
Guide to Installing BBL Crystal MIND on Windows 7 Introduction The BBL Crystal MIND software can not be directly installed on the Microsoft Windows 7 platform, however it can be installed and run via XP
More informationStatus Monitoring. Using Drivers by Seagull to Display Printer Status Information WHITE PAPER
Status Monitoring Using Drivers by Seagull to Display Printer Status Information WHITE PAPER Contents Printer Communications 3 Drivers by Seagull 3 The Seagull Status Monitor 4 Important Benefits 4 Viewing
More informationData Logging Software and Cable Bundle Model DL-SC3 User Manual. Overview
Data Logging Software and Cable Bundle Model DL-SC3 User Manual Overview Eco Sensors Digital Products are capable of transmitting data to a computer via an RS-232 serial connection. Eco Sensors DL-SC3
More informationRecommended KEPServerEX Settings for groov
Use this technical note to make sure that you are using Opto 22 s recommended settings in the KEPServerEX communication platform for successful communication with groov. In this technical note: Configuring
More information1 Installation. Note: In Windows operating systems, you must be logged in with administrator rights to install the printer driver.
Installation A printer driver is an application that manages communication between a printer and your computer. Once installed, the printer driver settings must be configured in the printer Properties
More informationBusiness Plus Accounting Hardware Setup Guide For Windows XP
Business Plus Accounting Hardware Setup Guide For Windows XP 1 Contents Chapter 1 - Description of Computer Ports...3 Chapter 2 - Connecting Your Touch Screen...4 Chapter 3 Setting Up Your Printers In
More informationTo get times into Arena Managemnt program, from the Farm Tek Timer Console.
To get times into Arena Managemnt program, from the Farm Tek Timer Console. You will need to purchase from Farm Tek the Computer Interface Cable, and a USB to Serial adapter id your computer does not have
More informationHow To Include Attachments with your Email form
How To Include Attachments with your Email form It s not uncommon for contact forms to include the ability to attach files to the email that is submitted. With two WebAssist extensions, Digital File Pro
More informationVirtual Integrated Design Getting started with RS232 Hex Com Tool v6.0
Virtual Integrated Design Getting started with RS232 Hex Com Tool v6.0 Copyright, 1999-2007 Virtual Integrated Design, All rights reserved. 1 Contents: 1. The Main Window. 2. The Port Setup Window. 3.
More informationAquadyne TechTip TITLE: TROUBLESHOOTING PC COM PORT AND MODEM PRODUCTS AFFECTED SYMPTOMS POSSIBLE CAUSES
Aquadyne TechTip TITLE: TROUBLESHOOTING PC COM PORT AND MODEM COMMUNICATIONS WITH AN OCTOPUS. Article # 072297-1 Last reviewed: 03/25/98 Keywords: Serial Port, Modem, Polling, AquaWeb, Node Not Responding
More informationDIRECT INTERNET 3. Install Guide for the Mac OS Operating System
DIRECT INTERNET 3 Install Guide for the Mac OS Operating System Iridium Communications Inc. Rev. 1; October 15, 2010 Overview Iridium s Direct Internet Data Service allows customers to connect directly
More informationSMS Alarm Messenger. Setup Software Guide. SMSPro_Setup. Revision 090210 [Version 2.2]
SMS Alarm Messenger SMSPro_Setup Revision 090210 [Version 2.2] ~ 1 ~ Contents 1. How to setup SMS Alarm Messenger?... 3 2. Install the SMSPro_Setup software... 5 3. Connection Type... 6 4. Connection Port
More information