IBM i PowerVM Virtualization 7.1 Update
|
|
- Ralph Willis
- 8 years ago
- Views:
Transcription
1 IBM i PowerVM Virtualization 7.1 Update Gottfried Schimunek Senior IT Architect Application Design IBM STG Software Development Lab Services IBM ISV Enablement 3605 Highway 52 North Rochester, MN Tel Fax Gottfried@us.ibm.com Acknowlegements Thanks to Kris Whitney for providing this comprehensive and detailed presentation 2 1
2 IBM s History of Virtualization Leadership A 40+ year tradition continues with PowerVM and VM Control TM IBM develops hypervisor that would become VM on the mainframe IBM announces first machines to do physical partitioning IBM announces LPAR on the mainframe IBM announces LPAR on POWER IBM intro s POWER Hypervisor for System p and System i IBM announces POWER6 Live Partition Mobility IBM announces PowerVM 3 PowerVM: Virtualization Without Limits Sold with more than 70% of Power Systems Improves IT resource utilization Reduces IT infrastructure costs Simplifies management 4 2
3 PowerVM Technologies The leading virtualization platform for UNIX, i and Linux enables a more agile and responsive infrastructure Hypervisor Support for multiple operating environments Dynamic Logical Partitioning Micro-partitioning, resource movement Multiple Shared Processor Pools Cap processor resources for a group of partitions Virtual I/O Server Virtualizes resources for client partitions Integrated Virtualization Manager Simplifies partition management for entry systems Lx86 Supports x86 Linux applications Live Partition Mobility Move running AIX and Linux partitions System Planning Tool Simplifies the planning for and installation of Power servers with PowerVM Power Hypervisor 5 PowerVM Editions: Built to Meet Client Virtualization Needs PowerVM Editions Express Standard Enterprise PowerVM Express Edition Evaluations, pilots, PoCs Single-server projects PowerVM Standard Edition Production deployments Server consolidation PowerVM Enterprise Edition Multi-server deployments Cloud infrastructure Maximum LPARs Management Virtual I/O Server PowerVM Lx86 Multiple Shared Processor Pools Live Partition Mobility 1+2 / Server VMControl IVM 10 / Core VMControl IVM, HMC 10 / Core VMControl IVM, HMC Active Memory Sharing PowerVM Editions offer a unified virtualization solution for any Power workloads 6 3
4 IBM i Virtualization Strategy Increased utilization of Power Systems hardware. Create a flexible infrastructure to allow for dynamic change. Begin to manage pools of systems as one. 7 Evolution towards: Fully Virtualized, Simplified, Lower cost Physical resource discovery / configuration / provisioning / update / system health OS provisioning Virtual IO Virtual Machine lifecycle mgmt Dynamic resource optimization within a physical system VLAN External virtualized storage + Mobility of Virtual Machines + Manually intensive server/storage/network mobility management + VM-based Availability/Resilience Mgmt + Storage Pools + IO virtualization and virtual switching + Hypervisor clustered fs access to virtual storage SW SW OS OS Virtl NW Virt Storage VM/LPAR VM/LPAR Virtual IO Svr Virtualization Storage vswitch Network Compute Memory +Mobility of workloads with automated and integrated server, network & storage provisioning + Workload-based Availability/Resilience Mgmt + Converged Datacenter Network fabric + Storage Pools with advanced capabilities (cloning, snapshot, thin provisioning, ) + Managing to QoS Policies (intelligent placement) + VM Security Appliance Image Library Virtual Appliance Image Image App Deployment App Image App OS Image OS App OS OS External virtualized switches Shared Network Workload Mobility SW OS SW OS Virtl NW Shared Storage Virtual Server Virtual Server Virt Storage Virtual IO Svr SW OS Virtl NW 8 Compute Virtualization Memory Storage Network Established: Physical systems with local virtualization VM/LPAR Compute Memory Virtualization Virt Storage Virtual IO Svr vswitch Storage Network Maturing: Multi-system virtualization managed across Physical Servers 11/23/2011 Optimized for. Availability Performance Energy Emerging: Virtual Appliances & Workload mobility within scalable and centrally managed System Pools (Ensembles) 4
5 Stage 1 Flexible I/O Infrastructure Current Support with IBM i 6.1 VSCSI Virtual Tape Virtual Optical Virtual Disk VETH IBM i server and IVM Current Support with IBM i NPIV MPIO SSD Enhancements Virtualization Management Enhancements 9 Two I/O Server Options IBM i IBM i Hypervisor POWER6 IBM i Hypervisor POWER6 Built into IBM i Host Disk and Optical Consolidate Ethernet Traffic Same technology as hosting AIX, Linux, and iscsi Server Host Disk and Optical Bridge Ethernet Traffic Attach external storage Advance Virtualization Functions 10 5
6 IBM i Hosting IBM i IBM i-based Virtualization IBM i partition uses I/O resources from another IBM i partition Eliminates requirement to buy adapters and disk drives for each IBM i partition Supports simple creation of additional partitions. e.g., for test and development Requires POWER6 server with IBM i 6.1 PowerVM not required Can mix virtual and direct I/O in client Platform support IBM POWER6 and POWER7 servers (except blade) Storage support Determined by host IBM i partition (SAN, EXP24, 12S, other integrated disk) LPAR management HMC IBM i IBM i Hypervisor POWER6 * All statements regarding IBM's future direction and intent are subject to change or withdrawal without notice, and represent goals and objectives only. 11 IBM i Host and Client Partitions: Overview FC 5294 EXP24/12S DS8000 NWSSTGs OPTxx IVE IBM i Host DVD DDxx Virtual SCSI connection Virtual LAN connection IBM i Client OPTxx CMNxx DDxx DVD Requirements POWER6 hardware IBM i 6.1 on host and client PowerVM not required HMC DASD Hardware assigned to host LPAR in HMC DASD can be integrated or SAN DASD virtualized as NWSSTG objects Optical DVD drive in host LPAR virtualized directly (OPTxx) Optical IMGCLG in host LPAR may be virtualized Networking Network adapter (such as IVE) and Virtual Ethernet adapter in host LPAR Virtual Ethernet adapter in client LPAR 12 6
7 IBM i Host VSCSI Virtual Optical -Load images into the IMGCLG on the Server. - Share the physical DVD/CD in the Server -Utilize them to install or save to in the Client. -Automatic switching of images 13 IBM or BP image or Physical media Ripping tool Current (v6.1, pre 4Q 09) supports loads of LPs, PTFs and data onto a v6.1 partition 4Q 09 upgrade/scratch ibm i v6.1.1 over existing 6.1 partition advantages OS install over LAN single copy of image breaks single CEC/PHYP limit requires: v6.1.1, phyp efw 3.5 and power 6 Electronic software distribution NFS image NFS image NFS Server (most any server except ) 2Q 10 support for ibm i v7.1 addition of power 7 4Q 10 scratch install of new partition requirements phyp efw 3.5 (or later) power 6 or power 7 HMC (or later) or DPSM Power system ibm i v6.1 (CRTDEVOPT *SRVLAN) SAVSYS, SAVOBJ, SAVLICPGM 14 7
8 IBM i Hosting IBM i Positioning Same technology as IBM i hosting AIX, LINUX, and iscsi x86 servers Leverage existing hardware investment Create new IBM i 6.1 LPARs using only virtual hardware (No IOAs, IOPs, disk units, I/O slots necessary for client partitions), but may also use physical I/O. Rapidly deploy new workloads Virtual disk created with 1 command or several clicks in System i Navigator New LPAR, virtual resources deployed dynamically Create test environments without hardware provisioning Virtual resources allow new test environments of exact size to be created, deleted without moving hardware Test new applications, tools, fixes in virtual test LPAR Test the next release in the client partition IBM i IBM i Hypervisor POWER6 * All statements regarding IBM's future direction and intent are subject to change or withdrawal without notice, and represent goals and objectives only. 15 -based Virtualization IBM i partition uses I/O resources from Virtual I/O Server () is included with all PowerVM Editions. Requires POWER6 systems with IBM i 6.1 Platform support IBM Power servers IBM BladeCenter JS12, JS22, JS23, JS43, PS701, PS702 Storage support Enables attachment to DS3000, DS4000, DS5000, SVC, XIV, DS8000 LPAR management HMC or IVM IBM i Hypervisor POWER6 Integrated Virtualization Manager Software for creating and managing partitions, part of Requires IBM i to use only virtual I/O resources 16 8
9 Virtual I/O Server () Disk IBM i -VSCSI disks are always 6B22-16 disks per virtual adapter -Thousands of virtual adapters DD001 (6B22) vtscsi1 hdisk1 (2107) DD002 DD003 (6B22) vtscsi2 vtscsi3 Storage Pool 1 hdisk2 (1815) hdisk2 hdisk3 (1815) (1815) hdisk3 (1815) hdisk4 (1815) hdisk4 (1815) -Flexible LUN sizes -Logical volume backed -File Backed DS8300 DS Disk Virtualization with VSCSI 1 Use storage UI and Redbook for your environment to create LUNs for IBM i and attach to (or use TPC or SSPC where applicable) 512B open storage LUNs DS Storage Manager for DS3200, DS3400, DS4700, DS4800, DS5100, DS5300 DS8000 Storage Manager for DS8100 and DS8300 SVC Console for SVC XIV Storage GUI for XIV 18 9
10 Disk Virtualization with VSCSI 2 IBM i Use HMC to create one or more pair of VSCSI adapters VSCSI server in, VSCSI client in IBM i DLPAR-capable 19 Disk Virtualization with VSCSI 3 Use HMC to assign LUNs to IBM i LPAR (DLPAR-capable) 20 10
11 Virtualization Enhancements for IBM i 1. IBM i 6.1 partition can host IBM i 7.1 and 6.1 partitions AIX 5.2, 5.3, 6.1 and SLES and Red Hat Linux partitions iscsi attached System x and BladeCenter 1. IBM i 7.1 partition can host IBM i 7.1 and 6.1 partitions AIX 5.2, 5.3, 6.1 and SLES and Red Hat Linux partitions iscsi attached System x and BladeCenter 2. PowerVM can host IBM i 7.1 and 6.1 partitions AIX and Linux partitions supports advanced virtualization technologies including Active Memory Sharing and NPIV Storage Virtualization can reduce costs while improving IT infrastructure flexibility IBM i 6.1 IBM i 7.1 IBM i 7.1 IBM i 6.1 POWER6 & POWER7 IBM i 7.1 IBM i 6.1 POWER6 & POWER7 IBM i 7.1 IBM i 6.1 POWER6 & POWER7 21 VSCSI Virtual Optical IBM i -Support for Physical and File Backed Optical (FBO) Drives. OPT01 (632C) vtscsi1 OPT02 (632C) vtscsi2 Storage Pool 1 - Read Only images may be shared to multiple virtual optical drives concurrently. CD0 File Backed Images hdisk2 (1815) hdisk3 (1815) hdisk4 (1815) 22 11
12 Support for IBM Storage Systems with IBM i Table as of Feb 10, 2011 N DS3200 DS3400 DS3500 DS3950 DS4700 DS4800 DS5020 Storwize V7000 DS5100 DS5300 DS6800 SVC XIV DS8100 DS8300 DS8700 DS / 6.1 Rack / Tower Systems IBM i Version Hardware 5.4 / POWER5/6/7 NOT DS3200# DS3500## POWER5/6/7 Not 7.1 ### POWER5/6/7 5.4 / POWER5/6/7 5.4 / POWER5/6/7 IBM i Attach IFS/NFS (NAS) Direct* or Direct Direct or NPIV** Direct or NPIV** Power Blades IBM i Version Hardware IFS/NFS (BCH) (BCH) Notes IBM i IFS/NFS n/a - This table Attach does not list (NAS) more detailed considerations, for example required levels of firmware or PTFs required or configuration performance NPIV** considerations NPIV** - POWER7 servers require IBM i 6.1 or later - This table can change over time as addition hardware/software capabilities/options are added # DS3200 only supports SAS connection, not supported on Rack/Tower servers which use only Fibre Channel connections ## DS3500 has either SAS or Fibre Channel connection. Ractk/Tower only uses Fibre Channel. Blades support either SAS or Fibre Channel ### Not supported on IBM i 7.1. But see SCORE System RPQ for exception support * Supported with Smart Fibre Channel adapters NOT supported with IOP-based Fibre Channel adapters ** NPIV requires Machine Code Level of or later and requires NPIV capable HBAs (FC adapters) and BCH supports DS3400, DS3500, DS3950 & BCS supports DS3200, N Series can only be used as file server. No load source/boot support. Support only through IFS. No IBM i data base support (BCH) Not supported (BCH) (BCH) (BCH) (BCH) For more details, use the System Storage Interoperability Center: Note there are currently some differences between the above table and the SSIC. The SSIC should be updated to reflect the above information 23 DS8300 Native, Through CPW Application Response Time (Milliseconds) Throughput (Transactions /Minute) DS8k native DS8k via Response Tim e (Milliseconds) CPW DB Disk Data Rate Throughput (MB/Sec) Response Time (Milliseconds) CPW JO Disk Data Rate Throughput (MB/Sec) DS8k native DS8k via DS8k native DS8k via 24 12
13 PowerVM Active Memory Sharing PowerVM Active Memory Sharing is an advanced memory virtualization technology which intelligently flows memory from one partition to another for increased utilization and flexibility of memory usage Memory virtualization enhancement for Power Systems Partitions share a pool of memory Memory dynamically allocated based on partition s workload demands Extends Power Systems Virtualization Leadership Capabilities not provided by Sun and HP virtualization offerings Designed for partitions with variable memory requirements Workloads that peak at different times across the partitions Active/inactive environments Test and Development environments Low average memory requirements Available with PowerVM Enterprise Edition Supports AIX 6.1, i 6.1, and SUSE Linux Enterprise Server 11 Partitions must use and shared processors POWER6 processor-based systems Memory Usage (GB) Memory Usage (GB) Memory Usage (GB) Around the World Time Day and Night Time Infrequent Use Time Asia Americas Europe Night Day #10 #9 #8 #7 #6 #5 #4 #3 #2 #1 25 AMS Geographic Mirroring Environment SAS JS12 in BladeCenter DS3200 IBM i IBM i DS3200 DS3K BCS3B2P1 Paging Devices BCS3B2P2 BCS3B2P3 MEMORY 5 drive sysbas 5 drive sysbas 16 GB Total Physical Mem IBM i 1 12 GB IBM i 2 12 GB 10 drives IASP Geographic Mirroring 10 drives IASP 26 13
14 Virtual Tape with VSCSI + GAed 5/2009 IBM i ptfs LTO4, DAT72, DAT160 All BRMS and Save/Restore function available. Library support not available with VSCSI, must use NPIV Also supported on non-blade Power Systems 27 Fibre Channel Tape library support with NPIV /2009 with (TS3500) with LTO drives 3573 (TS3100 TS3200) with LTO drives 2/2010 with (TS3400) with (TS1120/TS1130 ) drives 3584 (TS3500) with (TS1120/TS1130 ) drives 3576 (TS3310) with LTO drives TS7650, TS
15 SSD with Ability to share an array of SSDs among multiple partitions. With IBM i will recognize the drive as SSD Also can be used as a shared memory pool paging device. IBM i DD001 (6B22 HDD) DD002 DD003 (6B22 SSD) vtscsi1 hdisk1 HDD vtscsi2 vtscsi3 Storage Pool 1 hdisk2 (SSD) hdisk3 (SSD) hdisk4 (SSD) 29 IBM i Multi Path I/O Support IBM i DD001 (6B22) vtscsi1 hdisk1 (2107) Option 1 Multipath from the out to the external storage box. FCS0 FCS1 lun
16 IBM i Multi Path I/O Support DD001 (6B22) IBM i Logically mirrored disk Option 2 DD002 (6B22) -HMC managed systems -Mirroring across 2 LPARs - 2 copies of the data vtscsi1 1 hdisk1 (2107) vtscsi1 2 hdisk3 (2107) FCS0 FCS1 FCS0 FCS1 lun1 lun2 31 IBM i Multi Path I/O Support DD001 (6B22) IBM i DMP001 DD002 (6B22) - MPIO support across 2 LPARs (with HMC) - 1 copy of the data vtscsi1 1 hdisk1 (2107) vtscsi1 2 hdisk3 (2107) FCS0 FCS1 FCS0 FCS1 lun
17 IBM i + NPIV ( Virtual Fiber ) System 1 Source System 2 8Gbs HBA IBM i Client (System 1) IBM i Client (System 1) IBM i Client (System 1) System 3 Hypervisor assigns 2 unique WWPNs to each Virtual fiber Hostconnect is created as an iseries hosttype, Requires 520 byte per sector LUNs to be assigned to the iseries hostconnect Can Migrate existing direct connect LUNS Virtual address example C Hypervisor POWER6 with IBM i Note: Not available on blades until 4/2010 Note: an NPIV ( N_port ) capable switch is required to connect the to the DS8000 to use virtual fiber. 33 NPIV Configuration - Server Adapter Mappings 34 17
18 IBM i + NPIV ( Virtual Fiber ) with PowerHA Source SYSBAS 1 8Gbs HBA 2 IBM i Client 1 IASP 8Gbs HBA Each port is assigned separate WWPNs by the Hypervisor Each port is seen as a separate adapter by IBM i so PowerHA reset it individually. Reduces the hardware for a single partition from 4 to 2 adapters for PowerHA Hypervisor POWER6 with IBM i Note, This configuration can support up to 64 IBM i partitions without adding any more adapters 35 NPIV Performance (work in progress) NPIV vs Direct Attach (DS8300) Application Response Time CPW Use rs npiv run2 direct attach 36 18
19 PowerHA in the Virtual I/O Environment With VSCSI All Logical replication solutions supported including icluster PowerHA for i - Geographic mirroring With NPIV Metro Mirroring Global Mirroring Lun level switching 37 Virtualization Positioning Extend IBM i storage portfolio Existing investment in DS4000,SVC storage Allows consolidation of IBM i into existing SAN Lower end SAN attachment DS3000 New XIV attachment Existing environment Virtualization platform of choice is IBM i workloads can participate in existing virtualization environment IBM i Hypervisor POWER6 Positioning for future PowerVM advanced functions. Required for Blades. Provides lightweight partition management
20 2.2 - Integrated Storage Virtualization Integrated Storage Virtualization increases Platform Value Client Benefits Automated storage provisioning Non-disruptive Few interactions storage lifecycle between management mgmt domains Simplified, integrated Director Mgmt Director Consolidated integration to deliver on-line high level backup values = Decreased complexity and cost Advanced image management Storage integrated with Server Mgmt Infrastructures Consistent capabilities with different storage Consistent capabilities across different storage Server System Administrators Admin Virtual Servers Storage System Administrators SAN 39 Servers Admin Servers CPU Memory Storage CPU Memory Storage SynerStor Integrated Server & Storage Management Integrated Storage Capabilities Storage Aggregation Physical Storage administration Storage Mobility Snapshots & clones Thin Provisioning IBM, EMC, Hitachi, Other SAN Storage pooling SAN Virtualization Migration File Virtualization Copy services Caching Thin provisioning Geo mirroring NAS SOFS, NetApp, EMC, Other NAS Heterogeneous Questions 40 20
21 41 Trademarks and Disclaimers 8 IBM Corporation All rights reserved. References in this document to IBM products or services do not imply that IBM intends to make them available in every country. Trademarks of International Business Machines Corporation in the United States, other countries, or both can be found on the World Wide Web at Adobe, Acrobat, PostScript and all Adobe-based trademarks are either registered trademarks or trademarks of Adobe Systems Incorporated in the United States, other countries, or both. Intel, Intel logo, Intel Inside, Intel Inside logo, Intel Centrino, Intel Centrino logo, Celeron, Intel Xeon, Intel SpeedStep, Itanium, and Pentium are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries. Linux is a registered trademark of Linus Torvalds in the United States, other countries, or both. Microsoft, Windows, Windows NT, and the Windows logo are trademarks of Microsoft Corporation in the United States, other countries, or both. IT Infrastructure Library is a registered trademark of the Central Computer and Telecommunications Agency which is now part of the Office of Government Commerce. ITIL is a registered trademark, and a registered community trademark of the Office of Government Commerce, and is registered in the U.S. Patent and Trademark Office. UNIX is a registered trademark of The Open Group in the United States and other countries. Cell Broadband Engine and Cell/B.E. are trademarks of Sony Computer Entertainment, Inc., in the United States, other countries, or both and are used under license therefrom. Java and all Java-based trademarks are trademarks of Sun Microsystems, Inc. in the United States, other countries, or both. Other company, product, or service names may be trademarks or service marks of others. Information is provided "AS IS" without warranty of any kind. The customer examples described are presented as illustrations of how those customers have used IBM products and the results they may have achieved. Actual environmental costs and performance characteristics may vary by customer. Information concerning non-ibm products was obtained from a supplier of these products, published announcement material, or other publicly available sources and does not constitute an endorsement of such products by IBM. Sources for non-ibm list prices and performance numbers are taken from publicly available information, including vendor announcements and vendor worldwide homepages. IBM has not tested these products and cannot confirm the accuracy of performance, capability, or any other claims related to non-ibm products. Questions on the capability of non-ibm products should be addressed to the supplier of those products. All statements regarding IBM future direction and intent are subject to change or withdrawal without notice, and represent goals and objectives only. Some information addresses anticipated future capabilities. Such information is not intended as a definitive statement of a commitment to specific levels of performance, function or delivery schedules with respect to any future products. Such commitments are only made in IBM product announcements. The information is presented here to communicate IBM's current investment and development activities as a good faith effort to help with our customers' future planning. Performance is based on measurements and projections using standard IBM benchmarks in a controlled environment. The actual throughput or performance that any user will experience will vary depending upon considerations such as the amount of multiprogramming in the user's job stream, the I/O configuration, the storage configuration, and the workload processed. Therefore, no assurance can be given that an individual user will achieve throughput or performance improvements equivalent to the ratios stated here. Prices are suggested U.S. list prices and are subject to change without notice. Contact your IBM representative or Business Partner for the most current pricing in your geography
PowerVM and VIOS for IBM i
PowerVM and VIOS for IBM i QUSER user group meeting 3/19/2013 Minneapolis,MN Gottfried Schimunek Senior Architect Application Design IBM STG Software Development Lab Services IBM ISV Enablement 3605 Highway
More informationIBM i Virtualization and Open Storage. Mike Schambureck IBM Lab Services Rochester, MN
IBM i Virtualization and Open Storage Mike Schambureck IBM Lab Services Rochester, MN Partition Virtualization on POWER IO Virtualization with Dedicated Adapters IO Virtualization with a Hosting Server
More informationCloud Computing with xcat on z/vm 6.3
IBM System z Cloud Computing with xcat on z/vm 6.3 Thang Pham z/vm Development Lab thang.pham@us.ibm.com Trademarks The following are trademarks of the International Business Machines Corporation in the
More informationSAS deployment on IBM Power servers with IBM PowerVM dedicated-donating LPARs
SAS deployment on IBM Power servers with IBM PowerVM dedicated-donating LPARs Narayana Pattipati IBM Systems and Technology Group ISV Enablement January 2013 Table of contents Abstract... 1 IBM PowerVM
More informationTitle. Click to edit Master text styles Second level Third level
Title Click to edit Master text styles Second level Third level IBM s Vision For The New Enterprise Data Center Subram Natarajan Senior Consultant, STG Asia Pacific subram.natarajan@in.ibm.com Multiple
More informationIBM i Network Install using Network File System
IBM i Network Install using Network File System IBM i Virtual Media Rochester, Minnesota Version 1.5 February 22, 2013-1 - Table of Contents 1 Introduction... 3 1.1 What is IBM i Network Install?... 3
More informationHow To Manage Energy At An Energy Efficient Cost
Hans-Dieter Wehle, IBM Distinguished IT Specialist Virtualization and Green IT Energy Management in a Cloud Computing Environment Smarter Data Center Agenda Green IT Overview Energy Management Solutions
More informationEnergy Management in a Cloud Computing Environment
Hans-Dieter Wehle, IBM Distinguished IT Specialist Virtualization and Green IT Energy Management in a Cloud Computing Environment Smarter Data Center Agenda Green IT Overview Energy Management Solutions
More informationCapacity planning for IBM Power Systems using LPAR2RRD. www.lpar2rrd.com www.stor2rrd.com
Capacity planning for IBM Power Systems using LPAR2RRD Agenda LPAR2RRD and STOR2RRD basic introduction Capacity Planning practical view CPU Capacity Planning LPAR2RRD Premium features Future STOR2RRD quick
More informationHow to Deliver Measurable Business Value with the Enterprise CMDB
How to Deliver Measurable Business Value with the Enterprise CMDB James Moore jdmoore@us.ibm.com Product Manager, Business Service, Netcool/Impact 2010 IBM Corporation Agenda What is a CMDB? What are CMDB
More informationMaquette DB2 PureScale
Maquette DB2 PureScale PureScale et technologie Power7 Thierry Desbourdes thierry.desbourdes@fr.ibm.com DB2 PureScale Cluster Actif / Actif Automatic workload balancing On-Demand Provisioning Cluster de
More informationMicrosoft System Center 2012 SP1 Virtual Machine Manager with Storwize family products. IBM Systems and Technology Group ISV Enablement January 2014
Microsoft System Center 2012 SP1 Virtual Machine Manager with Storwize family products IBM Systems and Technology Group ISV Enablement January 2014 Copyright IBM Corporation, 2014 Table of contents Abstract...
More informationCloud Infrastructure Management - IBM VMControl
Cloud Infrastructure Management - IBM VMControl IBM Systems Director 6.3 VMControl 2.4 Thierry Huche IBM France - Montpellier thierry.huche@fr.ibm.com 2010 IBM Corporation Topics IBM Systems Director /
More informationWhat s the best disk storage for my i5/os workload?
What s the best disk storage for my i5/os workload? Sue Baker IBM System i Advanced Technical Support Agenda Storage management styles Storage technologies for i5/os Considerations for implementing and
More informationSession 1494: IBM Tivoli Storage FlashCopy Manager
Session 1494: IBM Tivoli Storage FlashCopy Manager Protecting your business-critical applications with IBM Tivoli Storage FlashCopy Manager 2011 IBM Corporation Session 1494: IBM Tivoli Storage FlashCopy
More informationIBM Systems Director Navigator for i5/os New Web console for i5, Fast, Easy, Ready
Agenda Key: Session Number: 35CA 540195 IBM Systems Director Navigator for i5/os New Web console for i5, Fast, Easy, Ready 8 Copyright IBM Corporation, 2008. All Rights Reserved. This publication may refer
More informationSession Title: Cloud Computing 101 What every z Person must know
2009 System z Expo October 5 9, 2009 Orlando, FL Session Title: Cloud Computing 101 What every z Person must know Session ID: ZDI08 Frank J. De Gilio - degilio@us.ibm.com 2 3 View of Cloud Computing Application
More informationVirtualization what it is?
IBM EMEA Virtualization what it is? Tomaž Vincek System p FTSS CEMAAS tomaz.vincek@si.ibm.com 2007 IBM Corporation What is needed? A very strong requirement: reduce costs and optimize investments On a
More informationGetting started with IBM i on an IBM Flex System compute node.
F Getting started with IBM i on an IBM Flex System compute node. Mike Schambureck (schambur@us.ibm.com) IBM i Lab Services,Rochester, MN Jan 2013 Getting Started with IBM i on an IBM PureFlex System Compute
More informationMigrating LAMP stack from x86 to Power using the Server Consolidation Tool
Migrating LAMP stack from x86 to Power using the Server Consolidation Tool Naveen N. Rao Lucio J.H. Correia IBM Linux Technology Center November 2014 Version 3.0 1 of 24 Table of Contents 1.Introduction...3
More informationVirtualization for IBM i
Virtualization for IBM i John Bizon jbizon@us.ibm.com Agenda Virtualization How do you define virtualization? The benefits of virtualization PowerVM IBM i Virtualization IBM i Hosting VIOS Hosting Comparison
More informationPositioning the Roadmap for POWER5 iseries and pseries
Positioning the Roadmap for POWER5 iseries and pseries Guy Paradise Larry Amy Ian Jarman Agenda The Case For Common Platforms Diverse Markets: the pseries and iseries Common Platform: the Roadmap for pseries
More informationHBA Virtualization Technologies for Windows OS Environments
HBA Virtualization Technologies for Windows OS Environments FC HBA Virtualization Keeping Pace with Virtualized Data Centers Executive Summary Today, Microsoft offers Virtual Server 2005 R2, a software
More informationMaximo Business Intelligence Reporting Roadmap Washington DC Users Group
Maximo Business Intelligence Reporting Roadmap Washington DC Users Group Pam Denny, IBM Email: pdenny@us.ibm.com Twitter: andbflo_denny May 2014 Please note IBM s statements regarding its plans, directions,
More informationRED HAT ENTERPRISE VIRTUALIZATION FOR SERVERS: COMPETITIVE FEATURES
RED HAT ENTERPRISE VIRTUALIZATION FOR SERVERS: COMPETITIVE FEATURES RED HAT ENTERPRISE VIRTUALIZATION FOR SERVERS Server virtualization offers tremendous benefits for enterprise IT organizations server
More informationViolin Memory Arrays With IBM System Storage SAN Volume Control
Technical White Paper Report Best Practices Guide: Violin Memory Arrays With IBM System Storage SAN Volume Control Implementation Best Practices and Performance Considerations Version 1.0 Abstract This
More informationIBM XIV Gen3 Storage System Storage built for VMware vsphere infrastructures
Storage built for VMware vsphere infrastructures Peter Kisich IBM Systems and Technology Group ISV Enablement October 2011 Copyright IBM Corporation, 2011 Table of contents Abstract...1 Introduction...1
More informationTSM for Virtual Environments Data Protection for VMware
for Virtual Environments Data Protection for VMware Wolfgang Hitzler Technical Sales IBM Tivoli Storage Management hitzler@de.ibm.com 2011 IBM Corporation Agenda Introduction for Virtual Environments 6.2
More informationShifting Gears: VMControl to PowerVC
ATS Experts Exchange November 2013 Shifting Gears: VMControl to PowerVC Glen Corneau, Agenda A review of VMControl Express, Standard and Enterprise Editions Image repositories System Pools PowerVC Based
More informationHP SN1000E 16 Gb Fibre Channel HBA Evaluation
HP SN1000E 16 Gb Fibre Channel HBA Evaluation Evaluation report prepared under contract with Emulex Executive Summary The computing industry is experiencing an increasing demand for storage performance
More informationPowerVC 1.2 Q4 2013 Power Systems Virtualization Center
PowerVC 1.2 Q4 2013 Power Systems Virtualization Center At last a simple tool to spin-off Power Virtual Machines with very little effort Nigel Griffiths IBM Power Systems Corporation Advanced Technology
More informationOracle on System z Linux- High Availability Options Session ID 252
Oracle on System z Linux- High Availability Options Session ID 252 Sam Amsavelu IBM Trademarks The following are trademarks of the International Business Machines Corporation in the United States and/or
More informationIntegrated Virtualization Manager ESCALA REFERENCE 86 A1 82FA 01
Integrated Virtualization Manager ESCALA REFERENCE 86 A1 82FA 01 ESCALA Integrated Virtualization Manager Hardware May 2009 BULL CEDOC 357 AVENUE PATTON B.P.20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE
More informationz/vm Capacity Planning Overview
z/vm Capacity Planning Overview Bill Bitner z/vm Development Lab Customer Focus and Care bitnerb@us.ibm.com 2012, 2013 IBM Corporation Trademarks The following are trademarks of the International Business
More informationHow To Write An Architecture For An Bm Security Framework
Security Reference Architecture James (Jimmy) Darwin James.Darwin@au.ibm.com 2010 IBM Corporation 0 Reference Architectures As part of the Time-to-Value Initiative, Reference Architectures have been identified
More informationExam : IBM 000-851. : Iseries Linux Soluton Sales v5r3
Exam : IBM 000-851 Title : Iseries Linux Soluton Sales v5r3 Version : R6.1 Prepking - King of Computer Certification Important Information, Please Read Carefully Other Prepking products A) Offline Testing
More informationUnleash the Performance of vsphere 5.1 with 16Gb Fibre Channel
W h i t e p a p e r Unleash the Performance of vsphere 5.1 with 16Gb Fibre Channel Introduction The July 2011 launch of the VMware vsphere 5.0 which included the ESXi 5.0 hypervisor along with vcloud Director
More informationVirtualized High Availability and Disaster Recovery Solutions
Virtualized High Availability and Disaster Recovery Solutions Microsoft on the IBM System Storage DS5000, IBM System x Servers, & IBM BladeCenter Highlights Windows Server 2008 and with MSCS failover cluster
More informationSystem z Batch Network Analyzer Tool (zbna) - Because Batch is Back!
System z Batch Network Analyzer Tool (zbna) - Because Batch is Back! John Burg IBM March 5, 2015 Session Number 16805 Insert Custom Session QR if Desired. Trademarks The following are trademarks of the
More informationBest Practices Guide: Network Convergence with Emulex LP21000 CNA & VMware ESX Server
Best Practices Guide: Network Convergence with Emulex LP21000 CNA & VMware ESX Server How to deploy Converged Networking with VMware ESX Server 3.5 Using Emulex FCoE Technology Table of Contents Introduction...
More informationFOR SERVERS 2.2: FEATURE matrix
RED hat ENTERPRISE VIRTUALIZATION FOR SERVERS 2.2: FEATURE matrix Red hat enterprise virtualization for servers Server virtualization offers tremendous benefits for enterprise IT organizations server consolidation,
More informationAgenda. Capacity Planning practical view CPU Capacity Planning LPAR2RRD LPAR2RRD. Discussion. Premium features Future
Agenda Capacity Planning practical view CPU Capacity Planning LPAR2RRD LPAR2RRD Premium features Future Discussion What is that? Does that save money? If so then how? Have you already have an IT capacity
More informationIBM Tivoli Storage FlashCopy Manager Overview Wolfgang Hitzler Technical Sales IBM Tivoli Storage Management hitzler@de.ibm.com
IBM Tivoli Storage FlashCopy Manager Overview Wolfgang Hitzler Technical Sales IBM Tivoli Storage Management hitzler@de.ibm.com Why Snapshots Are Useful for Backup Faster backups without taking applications
More informationEMC DATA PROTECTION. Backup ed Archivio su cui fare affidamento
EMC DATA PROTECTION Backup ed Archivio su cui fare affidamento 1 Challenges with Traditional Tape Tightening backup windows Lengthy restores Reliability, security and management issues Inability to meet
More informationWith Red Hat Enterprise Virtualization, you can: Take advantage of existing people skills and investments
RED HAT ENTERPRISE VIRTUALIZATION DATASHEET RED HAT ENTERPRISE VIRTUALIZATION AT A GLANCE Provides a complete end-toend enterprise virtualization solution for servers and desktop Provides an on-ramp to
More informationPowerHA SystemMirror for AIX V6.1
PowerHA SystemMirror for AIX V6.1 Systems Software leadership for innovation Mike Perry IT Specialist IBM Systems & Technology Group PowerHA High availability solutions for UNIX, i and Linux clients Cluster
More informationIBM and TEMENOS T24 workload optimization on the new IBM PureFlex System
IBM and TEMENOS T24 workload optimization on the new IBM PureFlex System TEMENOS T24 Enterprise performance testing using IBM POWER7 and x86 hybrid architectures with IBM DB2 v 9.7 Authors Temenos UK Simon
More informationSystemverwaltung 2009 AIX / LPAR
Systemverwaltung 2009 AIX / LPAR Course materials may not be reproduced in whole or in part without the prior written permission of IBM. 4.0.1 Integrated Virtualization Manager (IVM) (1 of 2) Provides
More informationHow To Connect Virtual Fibre Channel To A Virtual Box On A Hyperv Virtual Machine
Virtual Fibre Channel for Hyper-V Virtual Fibre Channel for Hyper-V, a new technology available in Microsoft Windows Server 2012, allows direct access to Fibre Channel (FC) shared storage by multiple guest
More informationAccelerate with ATS DS8000 Hardware Management Console (HMC) Best practices and Remote Support Configuration September 23rd, 2014.
North America ATS Storage Accelerate with ATS DS8000 Hardware Management Console (HMC) Best practices and Remote Support Configuration September 23rd, 2014 Thomas Fiege 1 2014 2014 IBM IBM Corporation
More informationPerformance and scalability of a large OLTP workload
Performance and scalability of a large OLTP workload ii Performance and scalability of a large OLTP workload Contents Performance and scalability of a large OLTP workload with DB2 9 for System z on Linux..............
More informationN_Port ID Virtualization
A Detailed Review Abstract This white paper provides a consolidated study on the (NPIV) feature and usage in different platforms and on NPIV integration with the EMC PowerPath on AIX platform. February
More informationIOmark- VDI. Nimbus Data Gemini Test Report: VDI- 130906- a Test Report Date: 6, September 2013. www.iomark.org
IOmark- VDI Nimbus Data Gemini Test Report: VDI- 130906- a Test Copyright 2010-2013 Evaluator Group, Inc. All rights reserved. IOmark- VDI, IOmark- VDI, VDI- IOmark, and IOmark are trademarks of Evaluator
More informationIOmark-VM. DotHill AssuredSAN Pro 5000. Test Report: VM- 130816-a Test Report Date: 16, August 2013. www.iomark.org
IOmark-VM DotHill AssuredSAN Pro 5000 Test Report: VM- 130816-a Test Report Date: 16, August 2013 Copyright 2010-2013 Evaluator Group, Inc. All rights reserved. IOmark-VM, IOmark-VDI, VDI-IOmark, and IOmark
More informationThe safer, easier way to help you pass any IT exams. Exam : 000-115. Storage Sales V2. Title : Version : Demo 1 / 5
Exam : 000-115 Title : Storage Sales V2 Version : Demo 1 / 5 1.The IBM TS7680 ProtecTIER Deduplication Gateway for System z solution is designed to provide all of the following EXCEPT: A. ESCON attach
More informationIEEE Mass Storage Conference Vendor Reception Lake Tahoe, NV
IEEE Mass Storage Conference Vendor Reception Lake Tahoe, NV 11 Manager May 04, 2010 Joe Rotiroti Client Systems IBM, Federal 484 433 9756 cell 845 491 5227 fax rotiroti@us.ibm.com How is GPFS different?
More informationIBM Smart Business Storage Cloud
GTS Systems Services IBM Smart Business Storage Cloud Reduce costs and improve performance with a scalable storage virtualization solution SoNAS Gerardo Kató Cloud Computing Solutions 2010 IBM Corporation
More informationEMC Invista: The Easy to Use Storage Manager
EMC s Invista SAN Virtualization System Tested Feb. 2006 Page 1 of 13 EMC Invista: The Easy to Use Storage Manager Invista delivers centrally managed LUN Virtualization, Data Mobility, and Copy Services
More informationArwed Tschoeke, Systems Architect tschoeke@de.ibm.com IBM Systems and Technology Group
Virtualization in a Nutshell Arwed Tschoeke, Systems Architect tschoeke@de.ibm.com and Technology Group Virtualization Say What? Virtual Resources Proxies for real resources: same interfaces/functions,
More informationJava Application Performance Analysis and Tuning on IBM System i
IBM Systems & Technology Group Technical Conference 14 18 April, 2008, Sevilla, Spain Java Application Performance Analysis and Tuning on IBM System i iap02 Gottfried Schimunek Gottfried Schimunek Senior
More informationPractical Web Services for RPG IBM Integrated Web services for i
Agenda Key: Session Number: 32CG 540191 Practical Web Services for RPG IBM Integrated Web services for i Dan Hiebert IBM dhiebert@us.ibm.com 8 Copyright IBM Corporation, 2009. All Rights Reserved. This
More informationIBM i on a POWER blade (read-me first)
IBM i on a POWER blade (read-me first) Installation and Configuration Guide Mike Schambureck and Keith Zblewski (schambur@us.ibm.com and zblewski@us.ibm.com) IBM i Lab Services,Rochester, MN April 2013
More informationVersion 8.2. Tivoli Endpoint Manager for Asset Discovery User's Guide
Version 8.2 Tivoli Endpoint Manager for Asset Discovery User's Guide Version 8.2 Tivoli Endpoint Manager for Asset Discovery User's Guide Note Before using this information and the product it supports,
More informationUN 4013 V - Virtual Tape Libraries solutions update...
UN 4013 V - Virtual Tape Libraries solutions update... - a Unisys storage partner Key issues when considering virtual tape Connectivity is my platform supported by whom? (for Unisys environments, MCP,
More informationIBM BladeCenter H with Cisco VFrame Software A Comparison with HP Virtual Connect
IBM BladeCenter H with Cisco VFrame Software A Comparison with HP Connect Executive Overview This white paper describes how Cisco VFrame Server Fabric ization Software works with IBM BladeCenter H to provide
More informationSymantec Storage Foundation and High Availability Solutions 6.2 Virtualization Guide - AIX
Symantec Storage Foundation and High Availability Solutions 6.2 Virtualization Guide - AIX August 2015 Symantec Storage Foundation and High Availability Solutions Virtualization Guide The software described
More informationWhy Use 16Gb Fibre Channel with Windows Server 2012 Deployments
W h i t e p a p e r Why Use 16Gb Fibre Channel with Windows Server 2012 Deployments Introduction Windows Server 2012 Hyper-V Storage Networking Microsoft s Windows Server 2012 platform is designed for
More informationCeph Distributed Storage for the Cloud An update of enterprise use-cases at BMW
Ceph Distributed Storage for the Cloud An update of enterprise use-cases at BMW Andreas Pöschl, BMW Senior Solutions Architect andreas.poeschl@bmw.de Michael Vonderbecke, BMW Solutions Architect michael.vonderbecke@bmwmc.com
More informationOracle Database Scalability in VMware ESX VMware ESX 3.5
Performance Study Oracle Database Scalability in VMware ESX VMware ESX 3.5 Database applications running on individual physical servers represent a large consolidation opportunity. However enterprises
More informationThe HBAs tested in this report are the Brocade 825 and the Emulex LPe12002 and LPe12000.
Emulex HBA Product Evaluation Evaluation report prepared under contract with Emulex Corporation Introduction Emulex Corporation commissioned Demartek to evaluate its 8 Gbps Fibre Channel host bus adapters
More informationHitachi Unified Compute Platform (UCP) Pro for VMware vsphere
Test Validation Hitachi Unified Compute Platform (UCP) Pro for VMware vsphere Author:, Sr. Partner, Evaluator Group April 2013 Enabling you to make the best technology decisions 2013 Evaluator Group, Inc.
More informationQuickSpecs. HP Integrity Virtual Machines (Integrity VM) Overview. Currently shipping versions:
Currently shipping versions: HP Integrity VM (HP-UX 11i v2 VM Host) v3.5 HP Integrity VM (HP-UX 11i v3 VM Host) v4.1 Integrity Virtual Machines (Integrity VM) is a soft partitioning and virtualization
More informationEmulex 8Gb Fibre Channel Expansion Card (CIOv) for IBM BladeCenter IBM BladeCenter at-a-glance guide
Emulex 8Gb Fibre Channel Expansion Card (CIOv) for IBM BladeCenter IBM BladeCenter at-a-glance guide The Emulex 8Gb Fibre Channel Expansion Card (CIOv) for IBM BladeCenter enables high-performance connection
More informationRedbooks Redpaper. IBM TotalStorage NAS Advantages of the Windows Powered OS. Roland Tretau
Redbooks Redpaper Roland Tretau IBM TotalStorage NAS Advantages of the Windows Powered OS Copyright IBM Corp. 2002. All rights reserved. ibm.com/redbooks 1 What is Network Attached Storage (NAS) Storage
More informationRFP-MM-1213-11067 Enterprise Storage Addendum 1
Purchasing Department August 16, 2012 RFP-MM-1213-11067 Enterprise Storage Addendum 1 A. SPECIFICATION CLARIFICATIONS / REVISIONS NONE B. REQUESTS FOR INFORMATION Oracle: 1) What version of Oracle is in
More informationIBM Storwize Rapid Application Storage solutions
IBM Storwize Rapid Application Storage solutions Efficient, integrated, pretested and powerful solutions to accelerate deployment and return on investment. Highlights Improve disk utilization by up to
More informationEffective Storage Management for Cloud Computing
IBM Software April 2010 Effective Management for Cloud Computing April 2010 smarter storage management Page 1 Page 2 EFFECTIVE STORAGE MANAGEMENT FOR CLOUD COMPUTING Contents: Introduction 3 Cloud Configurations
More informationForecasting Performance Metrics using the IBM Tivoli Performance Analyzer
Forecasting Performance Metrics using the IBM Tivoli Performance Analyzer Session 11523 August 8, 2012 Mike Bonett IBM Corporation, IBM Advanced Technical Skills bonett@us.ibm.com 1 Corporation Trademarks
More informationManaged Services - A Paradigm for Cloud- Based Business Continuity
Managed Services - A Paradigm for Cloud- Based Business Continuity Ron McCracken IBM 6 February 2013 Session Number 12993 Agenda This session is intended to expose key requirements for support of enterprise
More informationUsing idoctorjob Watcher to find out complex performance issues
2011 IBM Power Systems Technical University October 10-14 Fontainebleau Miami Beach Miami, FL Using idoctorjob Watcher to find out complex performance issues Gottfried Schimunek 3605 Highway 52 North Senior
More informationData Transfer Tips and Techniques
Agenda Key: Session Number: System i Access for Windows: Data Transfer Tips and Techniques 8 Copyright IBM Corporation, 2008. All Rights Reserved. This publication may refer to products that are not currently
More informationFeaturing: GUI screen designer to edit DDS source for 5250 Display Files
IBM Software Group Rational Developer for IBM i (RDi) Screen Designer Technology Preview Featuring: GUI screen designer to edit DDS source for 5250 Display Files Last Update: 11/25/2009 2009 IBM Corporation
More informationpræsentation oktober 2011
Johnny Olesen System X presale præsentation oktober 2011 2010 IBM Corporation 2 Hvem er jeg Dagens agenda Server overview System Director 3 4 Portfolio-wide Innovation with IBM System x and BladeCenter
More informationMICROSOFT CLOUD REFERENCE ARCHITECTURE: FOUNDATION
Reference Architecture Guide MICROSOFT CLOUD REFERENCE ARCHITECTURE: FOUNDATION EMC VNX, EMC VMAX, EMC ViPR, and EMC VPLEX Microsoft Windows Hyper-V, Microsoft Windows Azure Pack, and Microsoft System
More informationIBM Systems and Technology Group Technical Conference
IBM TRAINING IBM STG Technical Conference IBM Systems and Technology Group Technical Conference Munich, Germany April 16 20, 2007 IBM TRAINING IBM STG Technical Conference E72 Storage options and Disaster
More informationIBM Tivoli Storage Productivity Center (TPC)
IBM Tivoli Storage Productivity Center (TPC) Simplify, automate, and optimize storage infrastructure Highlights The IBM Tivoli Storage Productivity Center is designed to: Help centralize the management
More informationSAN Conceptual and Design Basics
TECHNICAL NOTE VMware Infrastructure 3 SAN Conceptual and Design Basics VMware ESX Server can be used in conjunction with a SAN (storage area network), a specialized high speed network that connects computer
More informationTip and Technique on creating adhoc reports in IBM Cognos Controller
Tip or Technique Tip and Technique on creating adhoc reports in IBM Cognos Product(s): IBM Cognos Area of Interest: Financial Management 2 Copyright and Trademarks Licensed Materials - Property of IBM.
More informationMicrosoft Exchange Solutions on VMware
Design and Sizing Examples: Microsoft Exchange Solutions on VMware Page 1 of 19 Contents 1. Introduction... 3 1.1. Overview... 3 1.2. Benefits of Running Exchange Server 2007 on VMware Infrastructure 3...
More informationNetapp Interoperability Matrix
Netapp Interoperability Matrix FC, FCoE, iscsi and NAS (NFS) Storage Interoperability The Interoperability Matrix (IMT) defines the components and versions that have been qualified and which can be used
More informationBest practices for data migration.
IBM Global Technology Services June 2007 Best practices for data migration. Methodologies for planning, designing, migrating and validating data migration Page 2 Contents 2 Executive summary 4 Introduction
More informationIBM i25 Trends & Directions
Gl. Avernæs 20. November 2013 Erik Rex Cert. Consultant rex@dk.ibm.com Thanks to Steve Will IBM i Chief Architect 2013 IBM Corporation The Family Tree 1975 1988 2013 2013 IBM Corporation 3 2013 IBM Corporation
More informationVirtualization 101 for Power Systems
Page 1 of 6 close window Virtualization 101 for Power Systems October November 2009 by Jaqui Lynch Print Table 1 Resources Since the introduction of POWER5* technology, virtualization has offered many
More informationHow To Evaluate Netapp Ethernet Storage System For A Test Drive
Performance evaluation sponsored by NetApp, Inc. Introduction Ethernet storage is advancing towards a converged storage network, supporting the traditional NFS, CIFS and iscsi storage protocols and adding
More informationFree performance monitoring and capacity planning for IBM Power Systems
Free performance monitoring and capacity planning for IBM Power Systems Pavel Hampl (pavel.hampl@xorux.com) XORUX s.r.o. 9.6.2014 Summary LPAR2RRD introduction HMC agent-less monitoring Data sources News
More information<Insert Picture Here> Infrastructure as a Service (IaaS) Cloud Computing for Enterprises
Infrastructure as a Service (IaaS) Cloud Computing for Enterprises Speaker Title The following is intended to outline our general product direction. It is intended for information
More informationCloud Optimize Your IT
Cloud Optimize Your IT Windows Server 2012 The information contained in this presentation relates to a pre-release product which may be substantially modified before it is commercially released. This pre-release
More informationMS Exchange Server Acceleration
White Paper MS Exchange Server Acceleration Using virtualization to dramatically maximize user experience for Microsoft Exchange Server Allon Cohen, PhD Scott Harlin OCZ Storage Solutions, Inc. A Toshiba
More informationEnd to end application delivery & Citrix XenServer 5. John Glendenning Vice President Server Virtualization, EMEA
End to end application delivery & Citrix XenServer 5 John Glendenning Vice President Server Virtualization, EMEA Businesses Run on Applications Users Apps 2 Users and Apps are Moving Further Apart Consolidation
More information