PowerVM and VIOS for IBM i

Size: px
Start display at page:

Download "PowerVM and VIOS for IBM i"

Transcription

1 PowerVM and VIOS for IBM i QUSER user group meeting 3/19/2013 Minneapolis,MN Gottfried Schimunek Senior Architect Application Design IBM STG Software Development Lab Services IBM ISV Enablement 3605 Highway 52 North Rochester, MN Tel Fax Gottfried@us.ibm.com

2 Acknowledgement Thanks to: Kris Whitney, Architect and lead developer - Power Virtual I/O,SAN,Comm Dev. 2

3 IBM s History of Virtualization Leadership A 40+ year tradition continues with PowerVM and VM Control 1967 IBM develops hypervisor that would become VM on the mainframe IBM announces first machines to do physical partitioning 1987 IBM announces LPAR on the mainframe 1999 IBM announces LPAR on POWER 2004 IBM intro s POWER Hypervisor for System p and System i 2007 TM 2008 IBM announces POWER6 Live Partition Mobility 2009 IBM announces PowerVM

4 PowerVM: Virtualization Without Limits Sold with more than 70% of Power Systems Improves IT resource utilization Reduces IT infrastructure costs Simplifies management 4

5 PowerVM Editions are tailored to client needs PowerVM Editions offer a unified virtualization solution for all Power workloads PowerVM Express Edition Evaluations, pilots, PoCs Single-server projects PowerVM Standard Edition Production deployments Server consolidation PowerVM Enterprise Edition Multi-server deployments Cloud infrastructure 5 PowerVM Editions Express Standard Enterprise Concurrent VMs 2 per server 20 per core** (up to 1000) 20 per core** (up to 1000) Virtual I/O Server NPIV Suspend/Resume Shared Processor Pools Shared Storage Pools Thin Provisioning Live Partition Mobility Active Memory Sharing ** Requires efw7.6 or higher

6 Evolution towards: Fully Virtualized, Simplified, Lower cost + Mobility of Virtual Machines + Manually intensive server/storage/network mobility management + VM-based Availability/Resilience Mgmt + Storage Pools OS provisioning + Hypervisor clustered fs access to virtual storage SW OS SW OS Virtl NW VM/LPAR VM/LPAR Virtualization vswitch Storage Network Compute Memory Dynamic resource optimization within a physical system VLAN External virtualized storage External virtualized switches Virtual IO Svr Shared Network Virtual Appliance Deployment Image Library Image App Image App Image OS App Image OS App OS OS Workload Mobility Shared Storage SW OS Virtl NW Virt Storage Virtual Server Virtual IO Svr SW OS Virtl NW VM/LPAR Virtual IO Svr Virtualization Compute + VM Security Appliance Virt Storage Virtual Machine lifecycle mgmt Virtual Server + Storage Pools with advanced capabilities (cloning, snapshot, thin provisioning, ) + Managing to QoS Policies (intelligent placement) Virtual IO SW OS + Workload-based Availability/Resilience Mgmt + Converged Datacenter Network fabric + IO virtualization and virtual switching Physical resource discovery / configuration / provisioning / update / system health +Mobility of workloads with automated and integrated server, network & storage provisioning Virt Storage Virtualization Memory Compute Memory Storage Network Established: Physical systems with local virtualization vswitch Network Storage Maturing: Multi-system virtualization managed across Physical Servers Optimized for. Availability Performance Energy Emerging: Virtual Appliances & Workload mobility within scalable and centrally managed System Pools (Ensembles) 6 03/17/13

7 Two I/O Server Options IBM i IBM i Hypervisor POWER6 Built into IBM i Host Disk, Optical, Tape 7 VIOS IBM i Hypervisor POWER6 VIOS Server Host Disk, Optical, Tape Consolidate Ethernet Traffic Bridge Ethernet Traffic Same technology as hosting AIX, Linux, and iscsi Attach external storage Advance Virtualization Functions

8 What is the VIOS? A special purpose appliance partition Provide I/O virtualization Advanced Partition Virtualization enabler 8 First GAed 2004 Built on top of AIX, but not an AIX partition IBM i first attached to VIOS in 2008 with the IBM i 6.1 VIOS is licensed with PowerVM

9 Why use the VIOS? I/O Capacity Utilization Storage Allocation Flexibility Ethernet Flexibility Memory Sharing Suspend/Resume Mobility 9

10 I/O Virtualization on POWER IO Bus Virtualization with Dedicated Adapters LPAR A IO Adapter Virtualization with VIO Server VIOS LPAR LPAR B LPAR A Physical Adapter DevDrv Physical Adapter DevDrv Increasing Adapter BW Physical Adapter DevDrv Virtual Virtual Adapter Adapter Server Server Virtual Adapter DevDrv LPAR B Virtual Adapter DevDrv & LPAR Hypervisor Density Virtual Fabric per Slot Hypervisor Func Func PCI adapter PCI adapter Port Port Func PCI adapter Port Fabric Fabric 10

11 IBM i + VSCSI (Classic) Source System 1 VIOS IBM i Client (System 1) IBM i Client (System 2) IBM i Client (System 3) System 2 FC HBA System 3 Assign storage to the physical HBA in the VIOS 6B22 6B22 6B22 Device Type Device Type Device Type Hostconnect is created as an open storage or AIX hosttype, Requires 512 byte per sector LUNs to be assigned to the hostconnect Cannot Migrate existing direct connect LUNs Hypervisor Many Storage options supported POWER6 with IBM i

12 Performance Does Virtualization Perform? Database ASP 16 Response Time in MS OPS VIOS DS5K 12 DA DS5K

13 IBM i + NPIV ( Virtual Fiber Chanel ) Source System 1 VIOS System 2 IBM i Client (System 1) IBM i Client (System 1) IBM i Client (System 1) 8Gbs HBA System 3 Hypervisor assigns 2 unique WWPNs to each Virtual fiber Hostconnect is created as an iseries hosttype, Requires 520 byte per sector LUNs to be assigned to the iseries hostconnect on DS8K Virtual address example C Hypervisor POWER6 with IBM i Can Migrate existing direct connect LUNS DS8100, DS8300, DS8700, DS8800, DS5100 and DS5300 SVC, V7000, V3700 supported 13 Note: an NPIV ( N_port ) capable switch is required to connect the VIOS to the DS8000 to use virtual fiber.

14 NPIV Concepts 14 Multiple VFC server adapters may map to the same physical adapter port. Each VFC server adapter connects to one VFC client adapter; each VFC client adapter gets a unique WWPN. Client WWPN stays the same regardless of physical port it is connected to. Support for dynamically changing the physical port to virtual port mapping. Clients can discover and manage physical devices on the SAN. VIOS can t access or emulate storage, just provides clients access to the SAN. Support for concurrent microcode download to the physical FC adapter

15 NPIV Configuration - Server Adapter Mappings 15

16 NPIV Performance NPIV vs Direct Attach (DS8300) 0.01 App licatio n Respon se Tim e CPW Users npiv run2 16 direct attach

17 Introducing the VIOS Performance Advisor What is it? The VIOS advisor is a standalone application that polls key performance metrics for minutes or hours, before analyzing the results to produce a report that summarizes the health of the environment and proposes potential actions that can be taken to address performance inhibitors. How does it work? STEP 2) STEP 1) Download VIOS Advisor Run Executable STEP 3) View XML File VIOS Advisor VIOS Partition VIOS Partition Only a single executable is required to run within the VIOS The VIOS Advisor can monitor from 5min and up to 24hours Open up.xml file using your favorite web-browser to get an easy to interpret report summarizing your VIOS status. 17

18 Sample Screenshot - SEA Performance interpretation combined with effective visual cues to alert clients about the state of the system and opportunities to optimize. INFORMATIVE: Context relevant data helpful in making adjustments OPTIMAL Current condition likely to deliver best performance WARNING: Current condition deviates from best practices. Opportunity likely exists for better performance. CRITICAL: Current condition likely causing negative performance impacts. 18

19 Customer Driven Features Your input matters More detailed Fibre channel adapter statistics to aid with resource planning. Additional Customer Driven Features Check for updates button Option to include timestamps in report name FC adapter, command element monitoring. Added server serial number to report. NEW NEW 19

20 VIOS Investigator New idoctor component released in May Combines NMON data and a VIOS to IBM i disk mapping process to analyze VIOS performance. - Includes an NPIV data collection and analysis function. - Includes functions to display the VIOS configuration. - PerfPMR data collection and send to IBM support. - Free (except NPIV analysis functions requires JW license) Future plans V7000 support Documentation (see chapter 10) 20

21 Analyzing NPIV: Advanced graphs - Total reads [VFC] 21

22 IBM i + NPIV ( Virtual Fiber ) with PowerHA SYSBAS IASP Source VIOS 1 IBM i Client 1 IBM i Client 2 VIOS 8Gbs HBA SYSBAS IASP Each port is assigned separate WWPNs by the Hypervisor Each port is seen as a separate adapter by IBM i so PowerHA reset it individually. Reduces the hardware for a single partition from 4 to 2 adapters for PowerHA 22 Hypervisor POWER6 with IBM i Note, This configuration can support up to 64 IBM i partitions without adding any more adapters

23 PowerHA in the Virtual I/O Environment With VSCSI All Logical replication solutions supported including icluster PowerHA for i - Geographic mirroring PowerHA for i Storwize V7000 Metro and Global Mirror support (4Q2011) With NPIV 23 All Logical replication solutions supported including icluster DS8000 Metro Mirroring DS8000 Global Mirroring DS8000 Lun Level Switching SVC/V7000 Metro Mirroring SVC/V7000 Global Mirroring SVC/V7000 Lun Level Switching

24 Redundant VIOS with NPIV POWER6 IBM i Client VFC adapters IASP Step 1: configure virtual and physical FC adapters SYSBAS Server VFC adapters 1 VIOS Best Practice to make VIOS redundant or separate individual VIOS partitions where a single hardware failure would not take down both VIOS partitions. Step 2: configure SAN fabric and storage Zone Luns to the virtual WWPNs. Each DASD sees a path through 2 VIOS partitions VIOS Notes: Support up to 8 paths per LUN Not all paths have to go through separate VIOS partitions. 2 New multi-path algorithm in 7.1 TR2 Physical FC connections 24

25 VIOS Storage attach Three categories of storage attachment to IBM i through VIOS 1) Supported (IBM storage) - tested by IBM; IBM supports the solution and owns resolution deliver the fix 2) Tested / Recognized (3rd party storage including EMC and Hitachi) - IBM / storage vendor collaboration, solution was tested (by vendor, IBM, or both); CSA in place, states that IBM and storage vendor will work together to resolve the issue storage vendor will deliver the fix 3) - IBM will - IBM or - Other - not tested by IBM, maybe not have been tested at all No commitment / obligation to provide fix Category #3 (Other) was introduced in the last few years, other storage used to invalidate the VIOS warranty. IBM Service has committed to provide some limited level of problem determination for service requests / issues involving "other storage. To the extent that they will try to isolate it to being a problem within VIOS or IBM i, or external to VIOS or IBM i (ie. a storage problem). No guarantee that a fix will be provided, even if the problem was identified as a VIOS or IBM i issue 25

26 Support for IBM Storage Systems with IBM i Table as of Feb, 2013 Rack / Tower Systems IBM i Version Hardware IBM i Attach Power Blades DS3200 DS3400 DS3500 DCS3700 DS / 7.1 POWER6/7 Not DS3200#, Yes DS3500## VIOS 6.1 / 7.1 IBM i Version #, ## Hardware IBM i Attach VIOS DS4700 DS4800 DS5020 SVC Storwize V7000 V3700 V3500 DS5100 DS5300 XIV DS8100 DS8300 DS8700 DS8800 DS / 7.1 POWER6/7 6.1 / 7.1 POWER6/7 6.1 / 7.1 POWER6/7 6.1 / 7.1 POWER6/7 5.4 / 6.1 / 7.1 POWER5/6/7 VIOS VIOS VSCSI and NPIV%% Direct* or VIOS VSCSI and NPIV% VIOS Direct or VIOS VSCSI and NPIV** 6.1 / 7.1 POWER6/7 (BCH) 6.1 / 7.1 POWER6/7 (BCH) 6.1 / 7.1 POWER6/7 (BCH) 6.1 / 7.1 POWER6/7 (BCH) 6.1 / 7.1 POWER6/7 (BCH) VIOS VIOS VIOS NPIV% VIOS VIOS NPIV** Notes - This table does not list more detailed considerations, for example required levels of firmware or PTFs required or configuration performance considerations - POWER7 servers require IBM i 6.1 or later - This table can change over time as addition hardware/software capabilities/options are added # DS3200 only supports SAS connection, not supported on Rack/Tower servers which use only Fibre Channel connections, supported on Blades with SAS ## DS3500 has either SAS or Fibre Channel connection. Rack/Tower only uses Fibre Channel. Blades in BCH support either SAS or Fibre Channel. Blades in BCS only uses SAS. ### Not supported on IBM i 7.1. But see SCORE System RPQ for exception support * Supported with Smart Fibre Channel adapters NOT supported with IOP-based Fibre Channel adapters ** NPIV requires Machine Code Level of or later and requires NPIV capable HBAs (FC adapters) and BCH supports DS3400, DS3500, DS3950 & BCS supports DS3200, DS3500 % NPIV requires IBM i 7.1 TR2 (Technology Refresh 2) and latest firmware released May 2011 or later %% NPIV requires IBM i 7.1 TR6 (Technology Refresh 6) For more details, use the System Storage Interoperability Center: Note there are currently some differences between the above table and the SSIC. The SSIC should be updated to reflect the above information 26

27 IBM PowerVM Virtual Ethernet Virtual I/O Server CMN (Phy) Shared Ethernet Adapter Part of the VIO server Logical device Bridges traffic to and from external networks Client 2 Shared Ethernet Adapter PowerVM Ethernet switch Part of PowerVM Hypervisor Moves data between LPARs Client 1 CMN (Vir) CMN (Vir) CMN (Vir) VLAN-Aware Ethernet Switch PowerVM Hypervisor Ethernet Switch Additional capabilities VLAN aware Link aggregation for external networks SEA Failover for redundancy 27

28 PowerVM Active Memory Sharing Reduce memory costs by improving memory utilization on Power Servers Supports over-commitment of logical memory with overflow going to a paging device POWER Server Intelligently flow memory from one partition to another for increased utilization and flexibility Dedicated Memory Shared Memory Memory from a shared physical memory pool is dynamically allocated among logical partitions as needed to optimize overall memory usage CPU Shared CPU Designed for partitions with variable memory requirements Virtual I/O Server Paging PowerVM Hypervisor AMS PowerVM Enterprise Edition on POWER6 and Power7 processor-based systems Partitions must use VIOS for I/O virtualization 28 * All statements regarding IBM's future direction and intent are subject to change or withdrawal without notice, and represent goals and objectives only.

29 LPAR Suspend/Resume Customer Value Resource balancing for long-running batch jobs e.g. suspend lower priority and/or long running workloads to free resources. Planned CEC outages for maintenance/upgrades Suspend/resume may be used in place of or in conjunction with partition mobility. Suspend/resume may require less time and effort than manual database shutdown and restart, for example. Requirements: All I/O is virtualized HMC version 7 releases 7.3 FW: Ax730_xxx IBM i 7.1 TR2 VIOS FP24 SP2 29

30 Live Partition Mobility Move a running partition from one Power7 server to another with no application downtime Movement to a different server with no loss of service Virtualized VirtualizedSAN SANand andnetwork NetworkInfrastructure Infrastructure Reduce planned downtime by moving workloads to another server during system maintenance Rebalance processing power across servers when and where you need it Live Partition Mobility requires the purchase of the optional PowerVM Enterprise Edition 30 30

31 Requirements Software HMC/Firmware version 7 releases 7.5 Firmware service pack 730_51, 740_40, or later PowerVM Enterprise Edition VIOS Supported client operating systems IBM i 7.1 TR4 I/O All I/O through the VIOS VSCSI, NPIV, VE External Storage Same storage to both source and destination Power7 tower / rack Hardware Both source and destination on same Ethernet network 31 31

32 Live Partition Mobility Partition Mobility supported on POWER7 IBM i 7.1 TR4 Power7 System #1 Power7 System #2 Suspended IBM i Client Partition 1 M M M M M M M A en0 (if) vscsi0 ent1 HMC VLAN Hypervisor VASI vhost0 ent1 Mover Service vtscsi0 ent2 SEA fcs0 ent0 Shell IBM i Partition Client 1 Once Finish enough the migration memory Validate environment Create Create pages and Startremove shell virtual migrating havepartition been SCSI the for appropriate moved, on memory original target devices suspend system LPAR pagesthe resources source definitions system M M M M M M M en0 (if) A ent1 vscsi0 VLAN Hypervisor en2 (if) VIOS ent1 vhost0 VASI en2 (if) ent2 SEA vtscsi0 Mover Service VIOS ent0 fcs0 Storage Subsystem A 32 IBM Confidential

33 Performance Considerations Active partition migration involves moving the state of a partition from one system to another while the partition is still running. Partition memory state is tracked while transferring memory state to the destination system Multiple memory transfers are done until a sufficient amount of clean pages have been moved. Memory updates on the source system affect transfer time Reduce the partition s memory update activity prior to the migration Network speed affects the transfer time Use a dedicated network, if possible At least 1Gb speed Possibly use link aggregated ports for more bandwidth 33 33

34 Application impacts during migration In general, applications and the operating system are unaware that the partition is moved from one system to another. There are some exceptions to this: Collection Services; when the partition is starting to run on the target system, the Collection Services collector job will cycle the collection so correct hardware information is recorded on the target system

35 PowerVM VIOS Shared Storage Pools Extending Storage Virtualization Beyond a Single System Storage Pool Storage Pool Storage Pool vscsi Classic storage virtualization Storage Pool vscsi NextGen clustered storage virtualization Storage pooled at VIOS for a single system Storage pool spans multiple VIOS s and servers Enables dynamic storage allocation Enabler for federated management Supports Local and SAN Storage, IBM and non-ibm Storage Location transparency Advanced capabilities Supports SAN and NAS, IBM and non-ibm Storage 35

36 VIOS Integrated Storage Virtualization Integrated Storage Virtualization increases Platform Value Client Benefits Automated storage provisioning Non-disruptive storage lifecycle management Few interactions between mgmt domains Simplified, integrated Director Mgmt Director integration on-line to deliver high level values Consolidated backup Advanced image management Storage integrated with Server Mgmt Consistent capabilities with different Infrastructures storagecapabilities across different storage Consistent = Decreased complexity and cost Server System Administrators Admin Storage System Administrators SAN Virtual Servers CPU Memory CPU Servers Memory Storage Integrated Server & Storage SynerStor Management Storage VIOS Admin VIOS Integrated Storage Capabilities IBM, EMC, Hitachi, Other SAN Storage pooling SAN Virtualization Migration File Virtualization Copy services Caching Thin provisioning Geo mirroring NAS Storage Aggregation Storage Mobility Snapshots & clones Servers 36 Thin Provisioning Physical Storage administration SOFS, NetApp, EMC, Other NAS Heterogeneous

37 VMControl Editions: Add value to PowerVM on Power Systems VMControl Virtualization Capabilities VMControl Express Edition Manage resources VMControl Standard Edition VMControl Enterprise Edition Automate virtual images Optimize system pools PowerVM Create/manage virtual machines (x86, PowerVM and z/vm) Virtual machine relocation Capture/import, create/remove standardized virtual images Deploy standard virtual images Maintain virtual images in a centralized library Create/remove system pools and manage system pool resources Add/remove physical servers within system pools 37 37

38 System Pools within IBM Systems Director Managing a pool of system resources with single systems simplicity IBM Systems Director VMControl Mobility System pools are being integrated as a new type of system with the IBM System Director tools, allowing the pool to be managed a single logical entity in the data center. Optimized for. Availability Performance Energy System Pool 38 A dashboard view for System pools will provide overall view of health and status of the pool and the deployed workloads. The dashboard will provide simplified monitoring and visualization of the aggregate capacity and utilization for the systems within a pool.

39 System Pool support for IBMi Images Technical Overview: Support the IBMi operating systems on the POWER platform. All system pool operations supported; deploy, capture, relocate, optimize. It is assumed that the image meets the hardware/ptf requirements when using the GUI to do a deploy. From the CLI/Rest Interfaces, you have the ability to mark that the image is not relocatable and it will not be moved. Hardware/Software Requirements: P7 hardware at firmware release or , Managed by IBM Hardware Management Console V7R7.5.0M0 or later IBMi image at v7r1 TR4 or later and PTF SI45682 Reference Information: PTF information: Infocenter information: =en#/wiki/ibm i Technology Updates/page/Live Partition Mobility Restrictions: Today, we are unable to determine if the image has the proper pre-reqs. The relocation will fail during relocation if the pre-reqs are not met. 39

40 NPIV Support in System Pools Technical Overview: NPIV, or N PortID Virtualization is now fully supported in System Pools on the POWER platform Deploy to system pool for a single or mulit-disk VA is now supported. System Pools can contain both vscsi and NPIV attached disks and will be handled appropriate in relocation and optimization functions. Virtual Appliances can describe disks that are NPIV and vscsi attached (mixed) for both deploy and capture. Image Repositories can be hosted on NPIV backed attached storage. Note: The storage connectivity is not preserved in the VA during capture. Restrictions: NPIV only supported on SAN storage When editing disks for a VS you cannot switch from vscsi to NPIV IBM i only will support this with SVC, Storwise V7000, V3700 or Flex V

41 Analyst commentary on PowerVM with POWER7 A data center scaling out to a cloudsupporting infrastructure or supporting multiple applications placing varying demands on system resources, would have to purchase, deploy, provision, and maintain a good deal more hardware and software with a VMWare based solution to achieve the same workload productivity possible with PowerVM on POWER7. Barry Cohen, CTO, Edison Group

42 PowerVM Client Success: GHY International Consolidating infrastructure benefits midsize business Business challenge: Predicting that international trade would increase as economic conditions improve, customs brokerage GHY International wanted to update its IT infrastructure to provide headroom for business growth. Solution: GHY International deployed an IBM Power 750, running IBM AIX, IBM i, and Linux on a single POWER7 system using IBM PowerVM and a separate IBM System x 3850 and VMware environment for Windows. Benefits: Enhanced scalability: IBM Power 750 delivers over four times the capacity of current server Easy manageability: A four-person IT team now spends just five percent versus 95 percent of its time on server management With PowerVM, we went from 95 percent to only 5% of our time managing or reacting to our environment. And saved the business hundreds of thousands of dollars in licensing and application fees. Nigel Fortlage, vice president of IT and CIO, GHY International Better energy efficiency: reduces electricity and cooling requirements with three operating systems running on one box 42 42

43 PowerVM on POWER7 delivers better scale-up and higher throughput performance than VMware vsphere AIM7 SingleVM Scale-up 131% vsphere % PowerVM advantage increases as we scale-up PowerVM is 103% better than vsphere and 131% better than vsphere vsphere 5.0 is no better than vsphere 4.1. Power cores (8cores/chip) vsphere Jobs/m in PowerVM on Power 750 delivers superior scale-up efficiency that outperforms vsphere 5.0 by up to 131%, running the same workloads across virtualized resources. PowerVM +103% # of vcpus HP Proliant DL580 G7 (Westmere EX) Xeon E cores (10 cores/chip) * A Comparison of PowerVM and VMware vsphere(4.1&5.0) Virtualization Performance, January =web-ibm-po-_-ws-powervm

44 PowerVM on POWER7 delivers better scale-out and higher throughput performance than VMware vsphere 525% AIM7 Multiple VM scale-out (32 vcpus per VM) PowerVM PowerVM on Power 750 outperforms VMware by up to 525% when running multiple VM s and workloads Jobs/Min PowerVM maximizes workload performance and all system resources. vsphere 5.0 has more cores but still can t compete with PowerVM Power cores (8cores/chip) vsphere5 8 VM HP Proliant DL580 G7 (Westmere EX) Xeon E cores (10 cores/chip) * A Comparison of PowerVM and VMware vsphere(4.1&5.0) Virtualization Performance, January =web-ibm-po-_-ws-powervm

45 PowerVM and POWER7 deliver a level of integration unmatched by VMware and x86 PowerVM VMware vsphere 5.0/5.1 High Performance Built-in hypervisor means all industry-leading Power Systems benchmarks are fully virtualized Degrades x86 workload performance by up to 30% compared to bare metal Elastic Scalability Scales to support the most demanding mission-critical enterprise workloads Imposes constraints that limit virtualization to small/medium workloads Extreme Flexibility Dynamically reallocates CPU, memory, storage and I/O without impacting workloads Limited hot-add of CPU and memory, with high risk of workload failures Maximum Security Embedded in Power Systems firmware and protected by secure access controls and encryption Downloaded software exposes more attack surfaces, with many published vulnerabilities Designed in sync with POWER processor and platform architecture road maps Third-party add-on software utility, developed in isolation from processor or systems Client Needs Platform Integration 45 45

46 Learn more about PowerVM on the Web ( or Google PowerVM and click I m Feeling Lucky) PowerVM resources include white papers, demos, client references and Redbooks 46 46

47 Resources and references Techdocs (presentations, tips & techniques, white papers, etc.) IBM PowerVM Virtualization Introduction and Configuration - SG IBM PowerVM Virtualization Managing and Monitoring - SG IBM PowerVM Virtualization Active Memory Sharing REDP IBM System p Advanced POWER Virtualization (PowerVM) Best Practices REDP Power Systems: Virtual I/O Server and Integrated Virtualization Manager commands (iphcg.pdf) 47

48 Trademarks and Disclaimers 8 IBM Corporation All rights reserved. References in this document to IBM products or services do not imply that IBM intends to make them available in every country. Trademarks of International Business Machines Corporation in the United States, other countries, or both can be found on the World Wide Web at Adobe, Acrobat, PostScript and all Adobe-based trademarks are either registered trademarks or trademarks of Adobe Systems Incorporated in the United States, other countries, or both. Intel, Intel logo, Intel Inside, Intel Inside logo, Intel Centrino, Intel Centrino logo, Celeron, Intel Xeon, Intel SpeedStep, Itanium, and Pentium are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries. Linux is a registered trademark of Linus Torvalds in the United States, other countries, or both. Microsoft, Windows, Windows NT, and the Windows logo are trademarks of Microsoft Corporation in the United States, other countries, or both. IT Infrastructure Library is a registered trademark of the Central Computer and Telecommunications Agency which is now part of the Office of Government Commerce. ITIL is a registered trademark, and a registered community trademark of the Office of Government Commerce, and is registered in the U.S. Patent and Trademark Office. UNIX is a registered trademark of The Open Group in the United States and other countries. Cell Broadband Engine and Cell/B.E. are trademarks of Sony Computer Entertainment, Inc., in the United States, other countries, or both and are used under license therefrom. Java and all Java-based trademarks are trademarks of Sun Microsystems, Inc. in the United States, other countries, or both. Other company, product, or service names may be trademarks or service marks of others. Information is provided "AS IS" without warranty of any kind. The customer examples described are presented as illustrations of how those customers have used IBM products and the results they may have achieved. Actual environmental costs and performance characteristics may vary by customer. Information concerning non-ibm products was obtained from a supplier of these products, published announcement material, or other publicly available sources and does not constitute an endorsement of such products by IBM. Sources for non-ibm list prices and performance numbers are taken from publicly available information, including vendor announcements and vendor worldwide homepages. IBM has not tested these products and cannot confirm the accuracy of performance, capability, or any other claims related to non-ibm products. Questions on the capability of non-ibm products should be addressed to the supplier of those products. All statements regarding IBM future direction and intent are subject to change or withdrawal without notice, and represent goals and objectives only. Some information addresses anticipated future capabilities. Such information is not intended as a definitive statement of a commitment to specific levels of performance, function or delivery schedules with respect to any future products. Such commitments are only made in IBM product announcements. The information is presented here to communicate IBM's current investment and development activities as a good faith effort to help with our customers' future planning. Performance is based on measurements and projections using standard IBM benchmarks in a controlled environment. The actual throughput or performance that any user will experience will vary depending upon considerations such as the amount of multiprogramming in the user's job stream, the I/O configuration, the storage configuration, and the workload processed. Therefore, no assurance can be given that an individual user will achieve throughput or performance improvements equivalent to the ratios stated here. Prices are suggested U.S. list prices and are subject to change without notice. Contact your IBM representative or Business Partner for the most current pricing in your geography. 48

IBM i PowerVM Virtualization 7.1 Update

IBM i PowerVM Virtualization 7.1 Update IBM i PowerVM Virtualization 7.1 Update Gottfried Schimunek Senior IT Architect Application Design IBM STG Software Development Lab Services IBM ISV Enablement 3605 Highway 52 North Rochester, MN 55901

More information

IBM i Virtualization and Open Storage. Mike Schambureck IBM Lab Services Rochester, MN

IBM i Virtualization and Open Storage. Mike Schambureck IBM Lab Services Rochester, MN IBM i Virtualization and Open Storage Mike Schambureck IBM Lab Services Rochester, MN Partition Virtualization on POWER IO Virtualization with Dedicated Adapters IO Virtualization with a Hosting Server

More information

How To Manage Energy At An Energy Efficient Cost

How To Manage Energy At An Energy Efficient Cost Hans-Dieter Wehle, IBM Distinguished IT Specialist Virtualization and Green IT Energy Management in a Cloud Computing Environment Smarter Data Center Agenda Green IT Overview Energy Management Solutions

More information

Energy Management in a Cloud Computing Environment

Energy Management in a Cloud Computing Environment Hans-Dieter Wehle, IBM Distinguished IT Specialist Virtualization and Green IT Energy Management in a Cloud Computing Environment Smarter Data Center Agenda Green IT Overview Energy Management Solutions

More information

Cloud Computing with xcat on z/vm 6.3

Cloud Computing with xcat on z/vm 6.3 IBM System z Cloud Computing with xcat on z/vm 6.3 Thang Pham z/vm Development Lab thang.pham@us.ibm.com Trademarks The following are trademarks of the International Business Machines Corporation in the

More information

Title. Click to edit Master text styles Second level Third level

Title. Click to edit Master text styles Second level Third level Title Click to edit Master text styles Second level Third level IBM s Vision For The New Enterprise Data Center Subram Natarajan Senior Consultant, STG Asia Pacific subram.natarajan@in.ibm.com Multiple

More information

SAS deployment on IBM Power servers with IBM PowerVM dedicated-donating LPARs

SAS deployment on IBM Power servers with IBM PowerVM dedicated-donating LPARs SAS deployment on IBM Power servers with IBM PowerVM dedicated-donating LPARs Narayana Pattipati IBM Systems and Technology Group ISV Enablement January 2013 Table of contents Abstract... 1 IBM PowerVM

More information

How to Deliver Measurable Business Value with the Enterprise CMDB

How to Deliver Measurable Business Value with the Enterprise CMDB How to Deliver Measurable Business Value with the Enterprise CMDB James Moore jdmoore@us.ibm.com Product Manager, Business Service, Netcool/Impact 2010 IBM Corporation Agenda What is a CMDB? What are CMDB

More information

Shifting Gears: VMControl to PowerVC

Shifting Gears: VMControl to PowerVC ATS Experts Exchange November 2013 Shifting Gears: VMControl to PowerVC Glen Corneau, Agenda A review of VMControl Express, Standard and Enterprise Editions Image repositories System Pools PowerVC Based

More information

Microsoft System Center 2012 SP1 Virtual Machine Manager with Storwize family products. IBM Systems and Technology Group ISV Enablement January 2014

Microsoft System Center 2012 SP1 Virtual Machine Manager with Storwize family products. IBM Systems and Technology Group ISV Enablement January 2014 Microsoft System Center 2012 SP1 Virtual Machine Manager with Storwize family products IBM Systems and Technology Group ISV Enablement January 2014 Copyright IBM Corporation, 2014 Table of contents Abstract...

More information

IBM i Network Install using Network File System

IBM i Network Install using Network File System IBM i Network Install using Network File System IBM i Virtual Media Rochester, Minnesota Version 1.5 February 22, 2013-1 - Table of Contents 1 Introduction... 3 1.1 What is IBM i Network Install?... 3

More information

Maquette DB2 PureScale

Maquette DB2 PureScale Maquette DB2 PureScale PureScale et technologie Power7 Thierry Desbourdes thierry.desbourdes@fr.ibm.com DB2 PureScale Cluster Actif / Actif Automatic workload balancing On-Demand Provisioning Cluster de

More information

RED HAT ENTERPRISE VIRTUALIZATION FOR SERVERS: COMPETITIVE FEATURES

RED HAT ENTERPRISE VIRTUALIZATION FOR SERVERS: COMPETITIVE FEATURES RED HAT ENTERPRISE VIRTUALIZATION FOR SERVERS: COMPETITIVE FEATURES RED HAT ENTERPRISE VIRTUALIZATION FOR SERVERS Server virtualization offers tremendous benefits for enterprise IT organizations server

More information

Cloud Infrastructure Management - IBM VMControl

Cloud Infrastructure Management - IBM VMControl Cloud Infrastructure Management - IBM VMControl IBM Systems Director 6.3 VMControl 2.4 Thierry Huche IBM France - Montpellier thierry.huche@fr.ibm.com 2010 IBM Corporation Topics IBM Systems Director /

More information

Getting started with IBM i on an IBM Flex System compute node.

Getting started with IBM i on an IBM Flex System compute node. F Getting started with IBM i on an IBM Flex System compute node. Mike Schambureck (schambur@us.ibm.com) IBM i Lab Services,Rochester, MN Jan 2013 Getting Started with IBM i on an IBM PureFlex System Compute

More information

N_Port ID Virtualization

N_Port ID Virtualization A Detailed Review Abstract This white paper provides a consolidated study on the (NPIV) feature and usage in different platforms and on NPIV integration with the EMC PowerPath on AIX platform. February

More information

Capacity planning for IBM Power Systems using LPAR2RRD. www.lpar2rrd.com www.stor2rrd.com

Capacity planning for IBM Power Systems using LPAR2RRD. www.lpar2rrd.com www.stor2rrd.com Capacity planning for IBM Power Systems using LPAR2RRD Agenda LPAR2RRD and STOR2RRD basic introduction Capacity Planning practical view CPU Capacity Planning LPAR2RRD Premium features Future STOR2RRD quick

More information

SAN Conceptual and Design Basics

SAN Conceptual and Design Basics TECHNICAL NOTE VMware Infrastructure 3 SAN Conceptual and Design Basics VMware ESX Server can be used in conjunction with a SAN (storage area network), a specialized high speed network that connects computer

More information

HBA Virtualization Technologies for Windows OS Environments

HBA Virtualization Technologies for Windows OS Environments HBA Virtualization Technologies for Windows OS Environments FC HBA Virtualization Keeping Pace with Virtualized Data Centers Executive Summary Today, Microsoft offers Virtual Server 2005 R2, a software

More information

What s the best disk storage for my i5/os workload?

What s the best disk storage for my i5/os workload? What s the best disk storage for my i5/os workload? Sue Baker IBM System i Advanced Technical Support Agenda Storage management styles Storage technologies for i5/os Considerations for implementing and

More information

IBM Systems Director Navigator for i5/os New Web console for i5, Fast, Easy, Ready

IBM Systems Director Navigator for i5/os New Web console for i5, Fast, Easy, Ready Agenda Key: Session Number: 35CA 540195 IBM Systems Director Navigator for i5/os New Web console for i5, Fast, Easy, Ready 8 Copyright IBM Corporation, 2008. All Rights Reserved. This publication may refer

More information

Maximo Business Intelligence Reporting Roadmap Washington DC Users Group

Maximo Business Intelligence Reporting Roadmap Washington DC Users Group Maximo Business Intelligence Reporting Roadmap Washington DC Users Group Pam Denny, IBM Email: pdenny@us.ibm.com Twitter: andbflo_denny May 2014 Please note IBM s statements regarding its plans, directions,

More information

Session 1494: IBM Tivoli Storage FlashCopy Manager

Session 1494: IBM Tivoli Storage FlashCopy Manager Session 1494: IBM Tivoli Storage FlashCopy Manager Protecting your business-critical applications with IBM Tivoli Storage FlashCopy Manager 2011 IBM Corporation Session 1494: IBM Tivoli Storage FlashCopy

More information

Cloud Optimize Your IT

Cloud Optimize Your IT Cloud Optimize Your IT Windows Server 2012 The information contained in this presentation relates to a pre-release product which may be substantially modified before it is commercially released. This pre-release

More information

FOR SERVERS 2.2: FEATURE matrix

FOR SERVERS 2.2: FEATURE matrix RED hat ENTERPRISE VIRTUALIZATION FOR SERVERS 2.2: FEATURE matrix Red hat enterprise virtualization for servers Server virtualization offers tremendous benefits for enterprise IT organizations server consolidation,

More information

Oracle on System z Linux- High Availability Options Session ID 252

Oracle on System z Linux- High Availability Options Session ID 252 Oracle on System z Linux- High Availability Options Session ID 252 Sam Amsavelu IBM Trademarks The following are trademarks of the International Business Machines Corporation in the United States and/or

More information

System z Batch Network Analyzer Tool (zbna) - Because Batch is Back!

System z Batch Network Analyzer Tool (zbna) - Because Batch is Back! System z Batch Network Analyzer Tool (zbna) - Because Batch is Back! John Burg IBM March 5, 2015 Session Number 16805 Insert Custom Session QR if Desired. Trademarks The following are trademarks of the

More information

How To Connect Virtual Fibre Channel To A Virtual Box On A Hyperv Virtual Machine

How To Connect Virtual Fibre Channel To A Virtual Box On A Hyperv Virtual Machine Virtual Fibre Channel for Hyper-V Virtual Fibre Channel for Hyper-V, a new technology available in Microsoft Windows Server 2012, allows direct access to Fibre Channel (FC) shared storage by multiple guest

More information

Unleash the Performance of vsphere 5.1 with 16Gb Fibre Channel

Unleash the Performance of vsphere 5.1 with 16Gb Fibre Channel W h i t e p a p e r Unleash the Performance of vsphere 5.1 with 16Gb Fibre Channel Introduction The July 2011 launch of the VMware vsphere 5.0 which included the ESXi 5.0 hypervisor along with vcloud Director

More information

Hitachi Unified Compute Platform (UCP) Pro for VMware vsphere

Hitachi Unified Compute Platform (UCP) Pro for VMware vsphere Test Validation Hitachi Unified Compute Platform (UCP) Pro for VMware vsphere Author:, Sr. Partner, Evaluator Group April 2013 Enabling you to make the best technology decisions 2013 Evaluator Group, Inc.

More information

IBM XIV Gen3 Storage System Storage built for VMware vsphere infrastructures

IBM XIV Gen3 Storage System Storage built for VMware vsphere infrastructures Storage built for VMware vsphere infrastructures Peter Kisich IBM Systems and Technology Group ISV Enablement October 2011 Copyright IBM Corporation, 2011 Table of contents Abstract...1 Introduction...1

More information

The Future of Computing Cisco Unified Computing System. Markus Kunstmann Channels Systems Engineer

The Future of Computing Cisco Unified Computing System. Markus Kunstmann Channels Systems Engineer The Future of Computing Cisco Unified Computing System Markus Kunstmann Channels Systems Engineer 2009 Cisco Systems, Inc. All rights reserved. Data Centers Are under Increasing Pressure Collaboration

More information

Enterprise Storage Solution for Hyper-V Private Cloud and VDI Deployments using Sanbolic s Melio Cloud Software Suite April 2011

Enterprise Storage Solution for Hyper-V Private Cloud and VDI Deployments using Sanbolic s Melio Cloud Software Suite April 2011 Enterprise Storage Solution for Hyper-V Private Cloud and VDI Deployments using Sanbolic s Melio Cloud Software Suite April 2011 Executive Summary Large enterprise Hyper-V deployments with a large number

More information

Best Practices Guide: Network Convergence with Emulex LP21000 CNA & VMware ESX Server

Best Practices Guide: Network Convergence with Emulex LP21000 CNA & VMware ESX Server Best Practices Guide: Network Convergence with Emulex LP21000 CNA & VMware ESX Server How to deploy Converged Networking with VMware ESX Server 3.5 Using Emulex FCoE Technology Table of Contents Introduction...

More information

IBM BladeCenter H with Cisco VFrame Software A Comparison with HP Virtual Connect

IBM BladeCenter H with Cisco VFrame Software A Comparison with HP Virtual Connect IBM BladeCenter H with Cisco VFrame Software A Comparison with HP Connect Executive Overview This white paper describes how Cisco VFrame Server Fabric ization Software works with IBM BladeCenter H to provide

More information

ORACLE OPS CENTER: PROVISIONING AND PATCH AUTOMATION PACK

ORACLE OPS CENTER: PROVISIONING AND PATCH AUTOMATION PACK ORACLE OPS CENTER: PROVISIONING AND PATCH AUTOMATION PACK KEY FEATURES PROVISION FROM BARE- METAL TO PRODUCTION QUICKLY AND EFFICIENTLY Controlled discovery with active control of your hardware Automatically

More information

Building the Virtual Information Infrastructure

Building the Virtual Information Infrastructure Technology Concepts and Business Considerations Abstract A virtual information infrastructure allows organizations to make the most of their data center environment by sharing computing, network, and storage

More information

PowerVC 1.2 Q4 2013 Power Systems Virtualization Center

PowerVC 1.2 Q4 2013 Power Systems Virtualization Center PowerVC 1.2 Q4 2013 Power Systems Virtualization Center At last a simple tool to spin-off Power Virtual Machines with very little effort Nigel Griffiths IBM Power Systems Corporation Advanced Technology

More information

Practical Web Services for RPG IBM Integrated Web services for i

Practical Web Services for RPG IBM Integrated Web services for i Agenda Key: Session Number: 32CG 540191 Practical Web Services for RPG IBM Integrated Web services for i Dan Hiebert IBM dhiebert@us.ibm.com 8 Copyright IBM Corporation, 2009. All Rights Reserved. This

More information

Red Hat enterprise virtualization 3.0 feature comparison

Red Hat enterprise virtualization 3.0 feature comparison Red Hat enterprise virtualization 3.0 feature comparison at a glance Red Hat Enterprise is the first fully open source, enterprise ready virtualization platform Compare the functionality of RHEV to VMware

More information

Migrating LAMP stack from x86 to Power using the Server Consolidation Tool

Migrating LAMP stack from x86 to Power using the Server Consolidation Tool Migrating LAMP stack from x86 to Power using the Server Consolidation Tool Naveen N. Rao Lucio J.H. Correia IBM Linux Technology Center November 2014 Version 3.0 1 of 24 Table of Contents 1.Introduction...3

More information

Performance and scalability of a large OLTP workload

Performance and scalability of a large OLTP workload Performance and scalability of a large OLTP workload ii Performance and scalability of a large OLTP workload Contents Performance and scalability of a large OLTP workload with DB2 9 for System z on Linux..............

More information

Step by Step Guide To vstorage Backup Server (Proxy) Sizing

Step by Step Guide To vstorage Backup Server (Proxy) Sizing Tivoli Storage Manager for Virtual Environments V6.3 Step by Step Guide To vstorage Backup Server (Proxy) Sizing 12 September 2012 1.1 Author: Dan Wolfe, Tivoli Software Advanced Technology Page 1 of 18

More information

EMC DATA PROTECTION. Backup ed Archivio su cui fare affidamento

EMC DATA PROTECTION. Backup ed Archivio su cui fare affidamento EMC DATA PROTECTION Backup ed Archivio su cui fare affidamento 1 Challenges with Traditional Tape Tightening backup windows Lengthy restores Reliability, security and management issues Inability to meet

More information

TSM for Virtual Environments Data Protection for VMware

TSM for Virtual Environments Data Protection for VMware for Virtual Environments Data Protection for VMware Wolfgang Hitzler Technical Sales IBM Tivoli Storage Management hitzler@de.ibm.com 2011 IBM Corporation Agenda Introduction for Virtual Environments 6.2

More information

Violin Memory Arrays With IBM System Storage SAN Volume Control

Violin Memory Arrays With IBM System Storage SAN Volume Control Technical White Paper Report Best Practices Guide: Violin Memory Arrays With IBM System Storage SAN Volume Control Implementation Best Practices and Performance Considerations Version 1.0 Abstract This

More information

IBM Storwize Rapid Application Storage solutions

IBM Storwize Rapid Application Storage solutions IBM Storwize Rapid Application Storage solutions Efficient, integrated, pretested and powerful solutions to accelerate deployment and return on investment. Highlights Improve disk utilization by up to

More information

Session Title: Cloud Computing 101 What every z Person must know

Session Title: Cloud Computing 101 What every z Person must know 2009 System z Expo October 5 9, 2009 Orlando, FL Session Title: Cloud Computing 101 What every z Person must know Session ID: ZDI08 Frank J. De Gilio - degilio@us.ibm.com 2 3 View of Cloud Computing Application

More information

z/vm Capacity Planning Overview

z/vm Capacity Planning Overview z/vm Capacity Planning Overview Bill Bitner z/vm Development Lab Customer Focus and Care bitnerb@us.ibm.com 2012, 2013 IBM Corporation Trademarks The following are trademarks of the International Business

More information

IBM and TEMENOS T24 workload optimization on the new IBM PureFlex System

IBM and TEMENOS T24 workload optimization on the new IBM PureFlex System IBM and TEMENOS T24 workload optimization on the new IBM PureFlex System TEMENOS T24 Enterprise performance testing using IBM POWER7 and x86 hybrid architectures with IBM DB2 v 9.7 Authors Temenos UK Simon

More information

Arwed Tschoeke, Systems Architect tschoeke@de.ibm.com IBM Systems and Technology Group

Arwed Tschoeke, Systems Architect tschoeke@de.ibm.com IBM Systems and Technology Group Virtualization in a Nutshell Arwed Tschoeke, Systems Architect tschoeke@de.ibm.com and Technology Group Virtualization Say What? Virtual Resources Proxies for real resources: same interfaces/functions,

More information

IBM i25 Trends & Directions

IBM i25 Trends & Directions Gl. Avernæs 20. November 2013 Erik Rex Cert. Consultant rex@dk.ibm.com Thanks to Steve Will IBM i Chief Architect 2013 IBM Corporation The Family Tree 1975 1988 2013 2013 IBM Corporation 3 2013 IBM Corporation

More information

Symantec Storage Foundation and High Availability Solutions 6.2 Virtualization Guide - AIX

Symantec Storage Foundation and High Availability Solutions 6.2 Virtualization Guide - AIX Symantec Storage Foundation and High Availability Solutions 6.2 Virtualization Guide - AIX August 2015 Symantec Storage Foundation and High Availability Solutions Virtualization Guide The software described

More information

With Red Hat Enterprise Virtualization, you can: Take advantage of existing people skills and investments

With Red Hat Enterprise Virtualization, you can: Take advantage of existing people skills and investments RED HAT ENTERPRISE VIRTUALIZATION DATASHEET RED HAT ENTERPRISE VIRTUALIZATION AT A GLANCE Provides a complete end-toend enterprise virtualization solution for servers and desktop Provides an on-ramp to

More information

NETAPP WHITE PAPER USING A NETWORK APPLIANCE SAN WITH VMWARE INFRASTRUCTURE 3 TO FACILITATE SERVER AND STORAGE CONSOLIDATION

NETAPP WHITE PAPER USING A NETWORK APPLIANCE SAN WITH VMWARE INFRASTRUCTURE 3 TO FACILITATE SERVER AND STORAGE CONSOLIDATION NETAPP WHITE PAPER USING A NETWORK APPLIANCE SAN WITH VMWARE INFRASTRUCTURE 3 TO FACILITATE SERVER AND STORAGE CONSOLIDATION Network Appliance, Inc. March 2007 TABLE OF CONTENTS 1 INTRODUCTION... 3 2 BACKGROUND...

More information

Virtualizing Microsoft SQL Server 2008 on the Hitachi Adaptable Modular Storage 2000 Family Using Microsoft Hyper-V

Virtualizing Microsoft SQL Server 2008 on the Hitachi Adaptable Modular Storage 2000 Family Using Microsoft Hyper-V Virtualizing Microsoft SQL Server 2008 on the Hitachi Adaptable Modular Storage 2000 Family Using Microsoft Hyper-V Implementation Guide By Eduardo Freitas and Ryan Sokolowski February 2010 Summary Deploying

More information

EMC Business Continuity for Microsoft SQL Server 2008

EMC Business Continuity for Microsoft SQL Server 2008 EMC Business Continuity for Microsoft SQL Server 2008 Enabled by EMC Celerra Fibre Channel, EMC MirrorView, VMware Site Recovery Manager, and VMware vsphere 4 Reference Architecture Copyright 2009, 2010

More information

<Insert Picture Here> Infrastructure as a Service (IaaS) Cloud Computing for Enterprises

<Insert Picture Here> Infrastructure as a Service (IaaS) Cloud Computing for Enterprises Infrastructure as a Service (IaaS) Cloud Computing for Enterprises Speaker Title The following is intended to outline our general product direction. It is intended for information

More information

The HBAs tested in this report are the Brocade 825 and the Emulex LPe12002 and LPe12000.

The HBAs tested in this report are the Brocade 825 and the Emulex LPe12002 and LPe12000. Emulex HBA Product Evaluation Evaluation report prepared under contract with Emulex Corporation Introduction Emulex Corporation commissioned Demartek to evaluate its 8 Gbps Fibre Channel host bus adapters

More information

Virtualized High Availability and Disaster Recovery Solutions

Virtualized High Availability and Disaster Recovery Solutions Virtualized High Availability and Disaster Recovery Solutions Microsoft on the IBM System Storage DS5000, IBM System x Servers, & IBM BladeCenter Highlights Windows Server 2008 and with MSCS failover cluster

More information

EMC Invista: The Easy to Use Storage Manager

EMC Invista: The Easy to Use Storage Manager EMC s Invista SAN Virtualization System Tested Feb. 2006 Page 1 of 13 EMC Invista: The Easy to Use Storage Manager Invista delivers centrally managed LUN Virtualization, Data Mobility, and Copy Services

More information

Microsoft Exchange Solutions on VMware

Microsoft Exchange Solutions on VMware Design and Sizing Examples: Microsoft Exchange Solutions on VMware Page 1 of 19 Contents 1. Introduction... 3 1.1. Overview... 3 1.2. Benefits of Running Exchange Server 2007 on VMware Infrastructure 3...

More information

MICROSOFT CLOUD REFERENCE ARCHITECTURE: FOUNDATION

MICROSOFT CLOUD REFERENCE ARCHITECTURE: FOUNDATION Reference Architecture Guide MICROSOFT CLOUD REFERENCE ARCHITECTURE: FOUNDATION EMC VNX, EMC VMAX, EMC ViPR, and EMC VPLEX Microsoft Windows Hyper-V, Microsoft Windows Azure Pack, and Microsoft System

More information

IBM Platform Computing Cloud Service Ready to use Platform LSF & Symphony clusters in the SoftLayer cloud

IBM Platform Computing Cloud Service Ready to use Platform LSF & Symphony clusters in the SoftLayer cloud IBM Platform Computing Cloud Service Ready to use Platform LSF & Symphony clusters in the SoftLayer cloud February 25, 2014 1 Agenda v Mapping clients needs to cloud technologies v Addressing your pain

More information

Optimized Storage Solution for Enterprise Scale Hyper-V Deployments

Optimized Storage Solution for Enterprise Scale Hyper-V Deployments Optimized Storage Solution for Enterprise Scale Hyper-V Deployments End-to-End Storage Solution Enabled by Sanbolic Melio FS and LaScala Software and EMC SAN Solutions Proof of Concept Published: March

More information

OPTIMIZING SERVER VIRTUALIZATION

OPTIMIZING SERVER VIRTUALIZATION OPTIMIZING SERVER VIRTUALIZATION HP MULTI-PORT SERVER ADAPTERS BASED ON INTEL ETHERNET TECHNOLOGY As enterprise-class server infrastructures adopt virtualization to improve total cost of ownership (TCO)

More information

Unit two is about the components for cloud computing.

Unit two is about the components for cloud computing. Unit two is about the components for cloud computing. Copyright IBM Corporation 2012 1 Please study this units learning objectives. Copyright IBM Corporation 2015 2 The diagram illustrates the virtual

More information

8Gb Fibre Channel Adapter of Choice in Microsoft Hyper-V Environments

8Gb Fibre Channel Adapter of Choice in Microsoft Hyper-V Environments 8Gb Fibre Channel Adapter of Choice in Microsoft Hyper-V Environments QLogic 8Gb Adapter Outperforms Emulex QLogic Offers Best Performance and Scalability in Hyper-V Environments Key Findings The QLogic

More information

Positioning the Roadmap for POWER5 iseries and pseries

Positioning the Roadmap for POWER5 iseries and pseries Positioning the Roadmap for POWER5 iseries and pseries Guy Paradise Larry Amy Ian Jarman Agenda The Case For Common Platforms Diverse Markets: the pseries and iseries Common Platform: the Roadmap for pseries

More information

Forecasting Performance Metrics using the IBM Tivoli Performance Analyzer

Forecasting Performance Metrics using the IBM Tivoli Performance Analyzer Forecasting Performance Metrics using the IBM Tivoli Performance Analyzer Session 11523 August 8, 2012 Mike Bonett IBM Corporation, IBM Advanced Technical Skills bonett@us.ibm.com 1 Corporation Trademarks

More information

HP SN1000E 16 Gb Fibre Channel HBA Evaluation

HP SN1000E 16 Gb Fibre Channel HBA Evaluation HP SN1000E 16 Gb Fibre Channel HBA Evaluation Evaluation report prepared under contract with Emulex Executive Summary The computing industry is experiencing an increasing demand for storage performance

More information

An Oracle White Paper August 2011. Oracle VM 3: Server Pool Deployment Planning Considerations for Scalability and Availability

An Oracle White Paper August 2011. Oracle VM 3: Server Pool Deployment Planning Considerations for Scalability and Availability An Oracle White Paper August 2011 Oracle VM 3: Server Pool Deployment Planning Considerations for Scalability and Availability Note This whitepaper discusses a number of considerations to be made when

More information

Virtualization what it is?

Virtualization what it is? IBM EMEA Virtualization what it is? Tomaž Vincek System p FTSS CEMAAS tomaz.vincek@si.ibm.com 2007 IBM Corporation What is needed? A very strong requirement: reduce costs and optimize investments On a

More information

How To Write An Architecture For An Bm Security Framework

How To Write An Architecture For An Bm Security Framework Security Reference Architecture James (Jimmy) Darwin James.Darwin@au.ibm.com 2010 IBM Corporation 0 Reference Architectures As part of the Time-to-Value Initiative, Reference Architectures have been identified

More information

Oracle Database Scalability in VMware ESX VMware ESX 3.5

Oracle Database Scalability in VMware ESX VMware ESX 3.5 Performance Study Oracle Database Scalability in VMware ESX VMware ESX 3.5 Database applications running on individual physical servers represent a large consolidation opportunity. However enterprises

More information

Solution Brief Availability and Recovery Options: Microsoft Exchange Solutions on VMware

Solution Brief Availability and Recovery Options: Microsoft Exchange Solutions on VMware Introduction By leveraging the inherent benefits of a virtualization based platform, a Microsoft Exchange Server 2007 deployment on VMware Infrastructure 3 offers a variety of availability and recovery

More information

IOmark- VDI. Nimbus Data Gemini Test Report: VDI- 130906- a Test Report Date: 6, September 2013. www.iomark.org

IOmark- VDI. Nimbus Data Gemini Test Report: VDI- 130906- a Test Report Date: 6, September 2013. www.iomark.org IOmark- VDI Nimbus Data Gemini Test Report: VDI- 130906- a Test Copyright 2010-2013 Evaluator Group, Inc. All rights reserved. IOmark- VDI, IOmark- VDI, VDI- IOmark, and IOmark are trademarks of Evaluator

More information

MS Exchange Server Acceleration

MS Exchange Server Acceleration White Paper MS Exchange Server Acceleration Using virtualization to dramatically maximize user experience for Microsoft Exchange Server Allon Cohen, PhD Scott Harlin OCZ Storage Solutions, Inc. A Toshiba

More information

Using EonStor FC-host Storage Systems in VMware Infrastructure 3 and vsphere 4

Using EonStor FC-host Storage Systems in VMware Infrastructure 3 and vsphere 4 Using EonStor FC-host Storage Systems in VMware Infrastructure 3 and vsphere 4 Application Note Abstract This application note explains the configure details of using Infortrend FC-host storage systems

More information

The Benefits of POWER7+ and PowerVM over Intel and an x86 Hypervisor

The Benefits of POWER7+ and PowerVM over Intel and an x86 Hypervisor The Benefits of POWER7+ and PowerVM over Intel and an x86 Hypervisor Howard Anglin rhbear@us.ibm.com IBM Competitive Project Office May 2013 Abstract...3 Virtualization and Why It Is Important...3 Resiliency

More information

SPEED your path to virtualization.

SPEED your path to virtualization. SPEED your path to virtualization. 2011 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice Introducing HP VirtualSystem Chief pillar of

More information

Virtualization Technologies and Blackboard: The Future of Blackboard Software on Multi-Core Technologies

Virtualization Technologies and Blackboard: The Future of Blackboard Software on Multi-Core Technologies Virtualization Technologies and Blackboard: The Future of Blackboard Software on Multi-Core Technologies Kurt Klemperer, Principal System Performance Engineer kklemperer@blackboard.com Agenda Session Length:

More information

IBM PureFlex System. The infrastructure system with integrated expertise

IBM PureFlex System. The infrastructure system with integrated expertise IBM PureFlex System The infrastructure system with integrated expertise 2 IBM PureFlex System IT is moving to the strategic center of business Over the last 100 years information technology has moved from

More information

Using idoctorjob Watcher to find out complex performance issues

Using idoctorjob Watcher to find out complex performance issues 2011 IBM Power Systems Technical University October 10-14 Fontainebleau Miami Beach Miami, FL Using idoctorjob Watcher to find out complex performance issues Gottfried Schimunek 3605 Highway 52 North Senior

More information

Open-E Data Storage Software and Intel Modular Server a certified virtualization solution

Open-E Data Storage Software and Intel Modular Server a certified virtualization solution Open-E Data Storage Software and Intel Modular Server a certified virtualization solution Contents 1. New challenges for SME IT environments 2. Open-E DSS V6 and Intel Modular Server: the ideal virtualization

More information

I/O Virtualization Using Mellanox InfiniBand And Channel I/O Virtualization (CIOV) Technology

I/O Virtualization Using Mellanox InfiniBand And Channel I/O Virtualization (CIOV) Technology I/O Virtualization Using Mellanox InfiniBand And Channel I/O Virtualization (CIOV) Technology Reduce I/O cost and power by 40 50% Reduce I/O real estate needs in blade servers through consolidation Maintain

More information

Cisco, Citrix, Microsoft, and NetApp Deliver Simplified High-Performance Infrastructure for Virtual Desktops

Cisco, Citrix, Microsoft, and NetApp Deliver Simplified High-Performance Infrastructure for Virtual Desktops Cisco, Citrix, Microsoft, and NetApp Deliver Simplified High-Performance Infrastructure for Virtual Desktops Greater Efficiency and Performance from the Industry Leaders Citrix XenDesktop with Microsoft

More information

Journey to the Private Cloud. Key Enabling Technologies

Journey to the Private Cloud. Key Enabling Technologies Journey to the Private Cloud Key Enabling Technologies Jeffrey Nick Chief Technology Officer Senior Vice President EMC Corporation June 2010 1 The current I/T state: Infrastructure sprawl Information explosion

More information

Java Application Performance Analysis and Tuning on IBM System i

Java Application Performance Analysis and Tuning on IBM System i IBM Systems & Technology Group Technical Conference 14 18 April, 2008, Sevilla, Spain Java Application Performance Analysis and Tuning on IBM System i iap02 Gottfried Schimunek Gottfried Schimunek Senior

More information

Dell High Availability Solutions Guide for Microsoft Hyper-V

Dell High Availability Solutions Guide for Microsoft Hyper-V Dell High Availability Solutions Guide for Microsoft Hyper-V www.dell.com support.dell.com Notes and Cautions NOTE: A NOTE indicates important information that helps you make better use of your computer.

More information

Best Practice of Server Virtualization Using Qsan SAN Storage System. F300Q / F400Q / F600Q Series P300Q / P400Q / P500Q / P600Q Series

Best Practice of Server Virtualization Using Qsan SAN Storage System. F300Q / F400Q / F600Q Series P300Q / P400Q / P500Q / P600Q Series Best Practice of Server Virtualization Using Qsan SAN Storage System F300Q / F400Q / F600Q Series P300Q / P400Q / P500Q / P600Q Series Version 1.0 July 2011 Copyright Copyright@2011, Qsan Technology, Inc.

More information

Storage Protocol Comparison White Paper TECHNICAL MARKETING DOCUMENTATION

Storage Protocol Comparison White Paper TECHNICAL MARKETING DOCUMENTATION Storage Protocol Comparison White Paper TECHNICAL MARKETING DOCUMENTATION v 1.0/Updated APRIl 2012 Table of Contents Introduction.... 3 Storage Protocol Comparison Table....4 Conclusion...10 About the

More information

Optimized Storage I/O for HPE Virtual Server Environments

Optimized Storage I/O for HPE Virtual Server Environments Optimized Storage I/O for HPE Virtual Server Environments HPE and QLogic Solutions Deliver Storage Networks that Enhance Virtual Server Environments HPE and QLogic provide Fibre Channel technology for

More information

IBM Storwize V7000 Unified and Storwize V7000 storage systems

IBM Storwize V7000 Unified and Storwize V7000 storage systems IBM Storwize V7000 Unified and Storwize V7000 storage systems Transforming the economics of data storage Highlights Meet changing business needs with virtualized, enterprise-class, flashoptimized modular

More information

Virtualizing the SAN with Software Defined Storage Networks

Virtualizing the SAN with Software Defined Storage Networks Software Defined Storage Networks Virtualizing the SAN with Software Defined Storage Networks Introduction Data Center architects continue to face many challenges as they respond to increasing demands

More information

Redbooks Redpaper. IBM TotalStorage NAS Advantages of the Windows Powered OS. Roland Tretau

Redbooks Redpaper. IBM TotalStorage NAS Advantages of the Windows Powered OS. Roland Tretau Redbooks Redpaper Roland Tretau IBM TotalStorage NAS Advantages of the Windows Powered OS Copyright IBM Corp. 2002. All rights reserved. ibm.com/redbooks 1 What is Network Attached Storage (NAS) Storage

More information

Evaluation of Enterprise Data Protection using SEP Software

Evaluation of Enterprise Data Protection using SEP Software Test Validation Test Validation - SEP sesam Enterprise Backup Software Evaluation of Enterprise Data Protection using SEP Software Author:... Enabling you to make the best technology decisions Backup &

More information

IBM Systems and Technology Group Technical Conference

IBM Systems and Technology Group Technical Conference IBM TRAINING IBM STG Technical Conference IBM Systems and Technology Group Technical Conference Munich, Germany April 16 20, 2007 IBM TRAINING IBM STG Technical Conference E72 Storage options and Disaster

More information

Virtualization of the MS Exchange Server Environment

Virtualization of the MS Exchange Server Environment MS Exchange Server Acceleration Maximizing Users in a Virtualized Environment with Flash-Powered Consolidation Allon Cohen, PhD OCZ Technology Group Introduction Microsoft (MS) Exchange Server is one of

More information