Mechanically Seamed Roof System Design / Installation Information
|
|
|
- Ross Powers
- 10 years ago
- Views:
Transcription
1 EM Mechanically Seamed Roof System Design / Installation Information
2 IMPORTANT NOTICE READ THIS MANUAL COMPLETELY PRIOR TO BEGINNING THE INSTALLATION OF THE CURVED BATTENLOK ROOFING SYSTEM. ALWAYS INSPECT EACH AND EVERY PANEL AND ALL ACCESSORIES BEFORE INSTALLATION. NEVER INSTALL ANY PRODUCT IF ITS QUALITY IS IN QUESTION. NOTIFY MBCI IMMEDIATELY IF ANY PRODUCT IS BELIEVED TO BE OUT OF TOLERANCE, SPECIFICATION OR HAS BEEN DAMAGED DURING SHIPMENT. IF THERE IS A CONFLICT BETWEEN PROJECT ERECTION DRAWINGS PROVIDED OR APPROVED BY THE MANUFACTURER AND DETAILS IN THIS MANUAL, PROJECT ERECTION DRAWINGS WILL TAKE PRECE- DENCE. Ice Dam Disclaimer MBCI designs its standing seam roofs to meet the load requirements dictated by governing codes and project specifications, including applicable snow loads. However, NCI expressly disclaims responsibilty for weathertightness or roof point loading issues or other hazards resulting from ice dam situations. Any time ice and snow can melt on the main body of the roof and refreeze at the eave or in the shadow of an adjacent wall, an ice dam situation may develop. In addition to local climate, ice dam formation is affected by many other factors, including but not limited to, roof insulation R value, roof panel color, interior temperature of building, heater location in building, eave overhangs, parapet walls, shading of building roof areas from adjacent trees, parapets, buildings, etc. These factors are design and maintenance issues and are outside the control of NCI. NCI specifically disclaims any liability for damage due to ice dam formation, although the following issues should be taken into consideration concerning standing seam roofs installed in freezing climates: Always use field seamed panels. These machine-folded seams are more durable when subjected to occasional icing. Eliminate "cold" eave overhangs and parapet walls from the building design. Roof overhangs outside the heated envelope of the building will tend to be colder than the roof areas over the heated envelope. Simple roof designs are preferred. Parapet walls at the eave allow ice and snow to collect due to shading effects and the lower roof temperatures caused thereby. Make sure the interior of the building is adequately insulated and the heating is properly distributed. Inadequate insulation in the roof and/or improper heat distribution causes heat flow though the main body of the roof. On days when the temperature is below freezing, this heat gain can cause ice and snow to melt and refreeze at the eave where the roof is colder. Lay out the building to prevent the eaves and other roof areas from being shaded during the winter. This may mean eliminating adjacent trees or reconsidering roof geometries. Consider using self-regulating heating cables at the eaves to mitigate the effects of ice dams. On building designs using attics, over-insulate the attic floor and provide adequate ventilation in the attic. This will reduce heat transfer through the roof resulting in more consistent roof temperatures between eave and field of roof. Increase the degree of diligence with respect to underlayment materials at roof areas prone to icing. This may include valleys, eaves, dormers and roof areas near dormers, parapets and the like where shading may occur. For more information on this subject, please refer to the MCA's Metal Roof Design For Cold Climates manual. The Engineering data contained herein is for the expressed use of customers and design professionals. Along with this data, it is recommended that the design professional have a copy of the most current version of the North American Specification for the Design of Cold-Formed Steel Structural Members published by the American Iron and Steel Institute to facilitate design. This Specification contains the design criteria for cold-formed steel components. Along with the Specification, the designer should reference the most current building code applicable to the project jobsite in order to determine environmental loads. If further information or guidance regarding cold-formed design practices is desired, please contact the manufacturer. Copyright NCI Group, Inc All Rights Reserved Descriptions and specifications contained herein were in effect at the time this publication was approved for printing. In a continuing effort to refine and improve products, MBCI reserves the right to discontinue products at any time or change specifications and/or designs without incurring obligation. To ensure you have the latest information available, please inquire or visit our website at Application details are for illustration purposes only and may not be appropriate for all environmental conditions, building designs or panel profiles. Projects should be designed to conform to applicable building codes, regulations and accepted industry practices. If there is a conflict between this manual and project erection drawings, the erection drawings will take precedence.
3 TABLE OF CONTENTS General Description CB-2 Ordering Information CB-3 Architect/ Engineer Information CB-4 UL 90/Section Properties/Load Chart CB-5 - CB-6 Specifications CB-7 - CB-12 Product Checklist CB-13 - CB-17 Preparatory Requirements CB-18 Unloading CB-19 Handling/ Panel Storage CB-20 Recommended Installation Techniques CB-21 - CB-22 Outside Closure Installation CB-23 Field Hemming Panel Ends CB-24 Design CB-25 Substrate Specific Details Wood Deck Eave Trim CB-26 Gutter CB-27 Valley CB-28 Endlap CB-29 Rake CB-30 - CB-31 High Eave CB-32 Parapet High Eave CB-33 Parapet Rake CB-34 - CB-35 Metal Deck With Rigid Insulation Eave Trim CB-36 Gutter CB-37 Valley CB-38 Endlap CB-39 Rake CB-40 - CB-41 High Eave CB-42 Parapet High Eave CB-43 Parapet Rake CB-44 - CB-45 Open Framing Eave CB-46 Gutter CB-47 Endlap CB-48 Rake CB-49 - CB-50 High Eave CB-51 Parapet High Eave CB-52 Parapet Rake CB-53 - CB-54 Seaming Information CB-55 - CB-56 EFFECTIVE MAY 15, 2014 SEE FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE CB-1
4 ROOFING SYSTEM GENERAL DESCRIPTION Coverage Width - 16 Minimum Radius Panel Attachment - Low, High (fixed or floating), or Utility (no insulation clearance) Panel Substrate - Galvalume (standard) Gauge - 24 Only Finishes - Smooth Striated (standard)* Coatings - Signature 200, Signature 300, or Signature 300 Metallic Signature 300 Signature 300 Signature 200 Galvalume Metallic Plus PRODUCT 24 Ga. 22 Ga. 24 Ga. 22 Ga. 24 Ga. 22 Ga. 24 Ga. 22 Ga. Curved BattenLok 16 Wide PRODUCT SELECTION CHART Signature is a registered trademark of NCI Group, Inc. Galvalume Plus is a registered trademark of BIEC International. - Available in any quantity. - Minimum quantity may be required. * - Striated panels are standard to reduce oil canning. CAUTION Diaphragm capabilities and purlin stability are not provided by MBCI s roof system. Therefore, other bracing may be required to conform to A.I.S.C. or A.I.S.I. specifications. CB-2 SUBJECT TO CHANGE WITHOUT NOTICE SEE FOR CURRENT INFORMATION EFFECTIVE MAY 15, 2014
5 GENERAL INFORMATION ORDERING INFORMATION I. When ordering panels without technical assistance from MBCI, the following must be provided: A. Panel Length - The length of each panel should include the proper overhang at the eave, endlap, and high eave as required. Refer to specific details in this manual for the proper overhang at these locations. If the panels are to be hemmed at the eave, add 1¹ ₂ to the panel length for each hem. B. panels requires the use of SuperLok Clips. Refer to product checklist. II. If your specific detail is not in this manual or if you have questions concerning panel length, designation or product application, call your MBCI sales representative. INSTALLATION GUIDELINES I. Pre-Order A. Prior to ordering panels, all dimensions should be confirmed by field measurement. II. Jobsite Storage and Handling A. Check the shipment against the shipping list. B. Damaged material must be noted on Bill of Lading. C. Panel crates should be handled carefully. A spreader bar of appropriate length is recommended for hoisting. D. Check to see that moisture has not formed inside the bundles during shipment. If moisture is present, panels should be uncrated and wiped dry, then restacked and loosely covered so that air can circulate between the panels. III. Application Checklist A. Check substructure for proper alignment and uniformity to avoid panel distortion. B. Periodic check of panel alignment is crucial to proper panel alignment. C. If there is a conflict between this manual and the project erection drawings, the erection drawings will take precedence. EFFECTIVE MAY 15, 2014 SEE FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE CB-3
6 GENERAL INFORMATION Architect/Engineer Information 1. is a mechanically seamed roof system. Panels are available in 16 width and 24 gauge only. Panels may be installed on roofs with radii of 20 or greater. 2. Roofs with chord lengths too large for single panel applications may be sheeted with multiple panels. Please see ordering information on Page CB-3 for proper panel designations. 3. Panels do not have factory applied mastic. ¹ ₂ x ³ ₃₂ tape mastic must be field applied to the male leg of the panels during roof installation. 4. is a structural roofing panel and may be installed directly over purlins or joists. It may also be installed over wood decks and metal deck with rigid insulation. 5. The substructure must be true. Any deviations in the substructure will telegraph through to the panels which may cause oil canning and other distortions. Panels cannot be installed over segmented decks. 6. The information in this manual is believed to be correct and accurate. It should not be used for any specific application without being reviewed by a registered professional engineer. 7. panels are not designed to be work platforms. Avoid any unnecessary foot traffic on panels. If foot traffic is required, protect the roof panels by using soft soled shoes and roof pads or temporary deck. 8. A vapor retarder may be necessary to protect roofing components when high interior humidity is a factor. The need for a vapor retarder, as well as the type, placement and location should be determined by an architect or engineer. The following are examples of conditions that may require a vapor retarder: (A) Projects where outside winter temperatures below 40 degrees Fahrenheit are anticipated and where average winter interior relative humidity of 45% or greater is expected. (B) Buildings with high humidity interiors, such as swimming pools, textile manufacturing operations, food, paper, or other wet-process industrial plants. (C) Construction elements that may release moisture after the roof is installed, such as interior concrete and masonry, plaster finishes and fuel burning heaters. 9. Typically, when wood decks are used, they are temporarily protected by the installation of a moisture barrier over the wood deck. If utility clips are to be used, the panel will lay tight to the wood deck. If tin tabs are used to attach the moisture barrier to the wood deck, they must be covered with duct tape or some other material to prevent them from rusting the back side of the panels. Also, plastic washers may telegraph through the panels. CB-4 SUBJECT TO CHANGE WITHOUT NOTICE SEE FOR CURRENT INFORMATION EFFECTIVE MAY 15, 2014
7 ENGINEERING UNDERWRITERS LABORATORIES APPROVAL Construction Panel Clip UL-2218 UL-263 UL-580 Number Width (In.) Gauge Clip Type Spacing Substrate Impact Fire Rating Rating Resistance " Fixed or Floating 24 min. High or Low 5'-0" Plywood / OSB Class 4 Class A Class " Fixed or Floating 24 min. High or Low 5'-0" Metal Deck Class 4 Class A Class " Fixed or Floating 24 min. High or Low 5'-0" Open Framing Class 4 Class A Class 90 NOTES 1. Tests procedures are in accordance with Underwriters Laboratories Standard UL-580 under Tests For Uplift Resistance of Roof Assemblies. 2. A detailed installation method is available for each Construction Number above and can be found in the UL Roofing Materials and Systems Directory. The panels must be installed in a certain manner to achieve the published results. 3. The panel qualifies for a Class A fire rating in compliance with Underwriters Laboratories Standard UL The panel system qualifies under the following Fire Resistance Design Numbers: P225, P227, P230, P237, P265, P268, P508, P510, P512, P701, P711, P720, P722, P726, P731, P734, P801, P815 and P panels carry a Class 4 rating under UL-2218 "test Standard For Impact Resistance". EFFECTIVE MAY 15, 2014 SEE FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE CB-5
8 ENGINEERING SECTION PROPERTIES NEGATIVE BENDING POSITIVE BENDING PANEL Fy WEIGHT Ixe Sxe Maxo Ixe Sxe Maxo GAUGE (KSI) (PSF) (IN.4/FT.) (IN.3/FT.) (KIP-IN.) (IN.4/FT.) (IN.3/FT.) (KIP-IN.) NOTES: 1. All calculations for the properties of Double-Lok panels are calculated in accordance with the 2012 Edition of the North American Specification For Design Of Cold-Formed Steel Structural Members. 2. Ixe is for deflection determination. 3. Sxe is for bending. 4. Maxo is allowable bending moment. 5. All values are for the one foot of panel width. 24 Gauge (Fy = 50 KSI) SPAN TYPE LOAD TYPE SPAN IN FEET SINGLE LIVE SPAN LIVE SPAN LIVE SPAN LIVE Gauge (Fy = 50 KSI) SPAN TYPE ALLOWABLE UNIFORM LOADES IN POUNDS PER SQUARE LOAD TYPE SPAN IN FEET SINGLE LIVE SPAN LIVE SPAN LIVE SPAN LIVE NOTES: 1. THE ABOVE LOADS ARE NOT FOR USE WHEN DESIGNING PANELS TO RESIST WIND UPLIFT 2. Strength calculations based on the 2012 AISI Standard "North American Specification for the Design of Cold-formed Steel Structural Members." 3. Allowable loads are applicable for uniform loading and spans without overhangs. 4. LIVE load capacities are for those loads that push the panel against its supports. The applicable limit states are flexure, shear, combined shear and flexure, web crippling at end and interior supports, and a deflection limit of L/180 under strength-level loads. 5. Panel pullover and Screw pullout capacity must be checked separately using the screws employed for each particular application when utilizing this load chart. 6. The use of any field seaming equipment or accessories including but not limited to clips, fasteners, and support plate other than tha provided by the manufacturer may (eave, backup, rake, etc.) damage panels, void all warranties and will void all engineering data. 7. This material is subject to change without notice. Please contact MBCI for the most current data. The Engineering data contained herein is for the expressed use of customers and design professionals. Along with this data, it is recommended that the design professional have a copy of the most current version of the North American Specification for the Design of Cold-Formed Steel Structural Members published by the American Iron and Steel Institute to facilitate design. This Specification contains the design criteria for cold-formed steel components. Along with the Specification, the designer should reference the most current building code applicable to the project jobsite in order to determine environmental loads. If further information or guidance regarding cold-formed design practices is desired, please contact the manufacturer. CB-6 SUBJECT TO CHANGE WITHOUT NOTICE SEE FOR CURRENT INFORMATION EFFECTIVE MAY 15, 2014
9 Specifier: Notation [#] means that text following is a specifier's note or sample. PART 1 - GENERAL 1.01 DESCRIPTION # Specifier: Do not alter paragraph "A" except by adding section title in brackets. A. General: 1. Furnish all labor, material, tools, equipment and services for all preformed [# choose one: roof, fascia, mansards, canopies, equipment screens] as indicated, in accord with provisions of Contract Documents. 2. Completely coordinate with work of all other trades. 3. Although such work is not specifically indicated, furnish and install all supplementary or miscellaneous items, appurtenances and devices incidental to or necessary for a sound, secure and complete installation. 4. See Division 1 for General Requirements. B. Related work specified elsewhere: 1. Structural steel: Section Steel joists: Section or Flashing and sheet metal: Section # Specifier: Delete references to sections not used and add any references that become pertinent QUALITY ASSURANCE A. Applicable standards: 1. SMACNA: "Architectural Sheet Metal Manual", Sheet Metal and Air Conditioning Contractors National Association, Inc. 2. LGSI: "Light Gage Structural Institute" 3. AISC: "Steel Construction Manual", American Institute of Steel Construction. 4. AISI: "Cold Form Steel Design Manual", American Iron and Steel Institute. 5. UL580: " Tests for Uplift Resistance of Roof Assembles", Underwriters Laboratories, Inc. 6. UL2218: Class 4 Impact Resistance Rating 7. ICBO: Evaluation Report No. ER-5409, ICBO Evaluation Service, Inc. 8. ASTM E : "Standard Test Method for Structural Performance of Sheet Metal Roof and Siding Systems by Uniform Static Air Pressure Difference", American Society for Testing and Materials. 9. ASTM A AZ50 (Painted) & ASTM A AZ55 (Bare Galvalume Plus ): "Specifications for SECTION Metal Roofing Steel Sheet, Aluminum-Zinc Alloy Coated (Galvanized) by the Hot Dip Process, General Requirements (Galvalume )", American Society for Testing and Materials. 10. ASTM E : "Standard Specification for Structural Standing Seam Steel Roof Panel Systems", American Society for Testing and Materials. 11. ASTM E : Standard Test Method for Total Normal Emittance of Surfaces Using Inspection- Meter Techniques. (Energy Star for Roof Products). 12. ASTM E Standard Test Method for Solar Absorptance, Using Integrating Spheres. (Energy Star for Roof Products) B. Manufacturer's qualifications: 1. Manufacturer has a minimum of five years experience in manufacturing metal roof systems of this nature. Panels specified in this section shall be produced in a factory environment (not with a portable roll former) with fixed-base roll forming equipment and in line leveling, assuring the highest level of quality control. A letter from the manufacturer certifying compliance will accompany the product material submittals. C. Installation contractor's qualifications: 1. Installation contractor shall be an approved installer, certified by the manufacturer before the beginning of installation of the metal roof system, specifically for MBCI's metal roof system, Certification by manufacturer must include the following: a. Maintain $250,000 minimum general liability insurance coverage. b. Maintain statutory limits of worker's compensation coverage as mandated by law. c. Have no viable claims pending regarding negligent acts or defective workmanship on previously performed or current projects. d. Has not filed for protection from creditors under any state or federal insolvency or debtor relief statutes or codes. e. Project foreman is the person having received certification by the manufacturer specific training in the proper installation of the selected metal roof system and will be present to supervise whenever material is being installed. Specific certified installer program shall include the following: NOTICE Contact MBCI for the proper combination of panel gauge, clip type, clip spacing and substructure to achieve a UL-90 rated system. SPECIFICATIONS EFFECTIVE MAY 15, 2014 SEE FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE CB-7
10 SPECIFICATIONS 1. The instructor must have a minimum of 10 years' experience in the application of metal roof systems. 2. A formal syllabus for the classroom and handson training. 3. Classroom instruction with review and thorough understanding of the specific product's technical manual. 4. Hands-on mock-up instruction with a review and thorough understanding of the specific product's details. 5. The installation contractor must pass a written and oral exam. f. Provide five references from five different architects or building owners for projects that have been in service for a minimum of two years, stating satisfactory performance by the installation contractor. g. Provide certification letter that installation contractor has a minimum of three years' of metal product installation experience immediately preceding the date upon which work is to commence. D. Pre-installation Conference: 1. Prior to installation of roofing system, conduct a pre-installation conference at the project site. 2. Attendance: Owner, Architect, Contractor, Project Superintendent, and Certified Installer 3. Agenda: a. Roofing details and agenda b. Critical work sequencing and review of phasing plan c. Inspection sequencing 1.03 SYSTEM PERFORMANCE REQUIREMENTS A. Performance Testing: 1. Metal roof system must be tested in accordance with Underwriters Laboratories, Inc. (UL) Test Method 580 "Tests for Uplift Resistance of Roof Assemblies". 2. Metal roof system must be installed in accordance with UL Construction # (choose one): #576 - (24 gauge panels) ⁵ ₈" plywood or OSB is required #577 - (24 gauge panels) 22 gauge metal deck is is required. Rigid insulation, plywood, or OSB is optional. #583 - (24 gauge panels) Blanket insulation, up to 6" thick, is optional. 3. Metal roof system must be tested in accordance with ASTM E for negative loading. Determine panel bending and clip-to-panel strength by testing in accordance with ASTM E procedures. Capacity for gauge, span or SECTION Metal Roofing loading other than those tested may be determined by interpolating between test values only. 4. Roof Panels shall be high reflectance and high emittance in accordance with Energy Star. Initial Reflectance shall be at least 0.68 when tested with ASTM E The three year aged reflectance shall be at least 0.57, when tested in accordance with ASTM E-1918 (Measured As Solar Reflectivity, Not Visible Reflectance) DESIGN REQUIREMENTS A. Roof Design Loads: 1. Design criteria shall be in accordance with [# choose one: MBMA, SBCCI, UBC, BOCA, ASCE or an applicable national or local building code]. 2. Dead Loads a. The dead load shall be the weight of the SSMR system. Collateral loads, such as sprinklers, mechanical and electrical systems, and ceilings shall not be attached to the panels. 3. Live Loads a. The panels and concealed anchor clips shall be capable of supporting a minimum uniform live load of 20 psf. 4. Roof Snow Loads a. The design roof snow loads shall be as shown on the contract drawings. 5. Wind Loads a. The design wind uplift pressure for the roof system shall be as shown on the contract drawings. The design uplift force for each connection assembly in accordance with ASTM E 1592 shall be that pressure given for the area under consideration, multiplied by the tributary load area of the connection assembly. The safety factor listed below shall be applied to the design force and compared against the ultimate capacity. Prying shall be considered when calculating fastener design loads. aa. Single fastener in each connection: 3.00 bb. Two or more fasteners in each connection: 2.25 CB-8 SUBJECT TO CHANGE WITHOUT NOTICE SEE FOR CURRENT INFORMATION EFFECTIVE MAY 15, 2014
11 6. Thermal Loads a. Roof panels shall be free to move in response to the expansion and contraction forces resulting from a total temperature range of degrees F during the life of the structure. [# Choose temperature differential based on Max. and Min. for specific area IAW MBMA Climatological Data] #Specifier: Select applicable building code for paragraph A.1 Select Temperature Differential for paragraph A.6. B. Framing Members Supporting the SSSMR System 1. Any additions/revisions to framing members supporting the SSMR system to accommodate the manufacturer/fabricator's design shall be the Contractor's responsibility and shall be submitted for review and approval. New or revised framing members and their connections shall be designed in accordance with [\-AISC-\] [\-AISI-\] [\-SJI-\] [\-LGSI-\] design specifications. Maximum deflection under applied live load, snow or wind load shall not exceed [# choose one: L/180, L/240] of the span length SUBMITTALS A. Shop drawings: 1. Submit complete shop drawings and erection details, approved by the metal roofing manufacturer, to the architect (owner) for review. Do not proceed with manufacture of roofing materials prior to review of shop drawings and field verification of all dimensions. Do not use drawings prepared by the architect (owner) for shop or erection drawings. 2. Shop drawings show methods of erection, roof and wall panel layout, sections and details, anticipated loads, flashings, sealants, interfaces with all materials not supplied and proposed identification of component parts and their finishes. B. Performance Tests: 1. Submit certified test results by a recognized testing laboratory or manufacturer's lab (witnessed by a professional engineer) in accordance with specified test methods for each panel system. C. Calculations: 1. Submit engineering calculations defining all cladding loads for all roof areas based on design criteria listed in Para 1.04 Design Requirements, allowable clip loads and required number of fasteners to secure the panel clips to the designated substructure. 2. Compute uplift loads on clip fasteners with full recognition of prying forces and eccentric clip loading. 3. Calculate holding strength of fasteners in accordance with submitted test data provided by the SECTION Metal Roofing SPECIFICATIONS fastener manufacturer based on length of embedment and properties of materials. 4. Submit thermal calculations and details of floating clip, flashing attachments, and accessories certifying the free movement in response to the expansion/ contraction forces resulting from a total temperature differential of 110 degrees F. D. Samples: 1. Submit samples and color chips for all proposed finishes. a. Submit one 8-inch long sample of panel, including clips. b. Submit two 3 inches x 5 inch color chip samples in color selected by the architect (owner). E. Warranties: 1. Metal roof system manufacturer shall submit a specimen copy of the warranty upon final acceptance of the project. Provide one of the following warranties. 1) Finish Warranty: a. Covering bare metal against rupture, structural failure and perforation due to normal atmospheric corrosion exposure for a period of 20 years. b. Covering panel finish against cracking, checking, blistering, peeling, flaking, chipping, chalking and fading for a period of twenty (20) years. 2) Weathertightness Warranty: Roofing contractor shall submit a specimen copy of manufacturer's Weathertightness Warranty, including evidence of application for warranty and manufacturer's acceptance of the applicator and warranty conditions. (Choose one noted below.) a. Single Source Warranty b. Standard Warranty F. Test Reports: 1. Submit Test Reports showing that metal panels have been tested in accordance with the Standard Test Method for Structural Performance of Sheet Metal Roof and Siding Systems by Uniform Static Air Pressure Difference of ASTM E Submit Test Reports showing that metal panels meet the air infiltration requirements of ASTM E when tested with a 6.24 PSF pressure differential with resulting air infiltration of cfm/sq. ft. EFFECTIVE MAY 15, 2014 SEE FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE CB-9
12 SPECIFICATIONS 3. Submit Test Reports showing that metal panels meet the water penetration requirements of ASTM E when tested with a PSF pressure differential with no uncontrollable water leakage when five gallons per hour of water is sprayed per square foot of roof area. G. Metal roof system fabrication certification 1. Submit a letter from the metal roof system manufacturer certifying the panels have been produced in a factory environment (not job site roll formed) with fixed-base roll forming equipment and in line leveling H. Certified Installers qualifications: 1. Submit certificate from manufacturer certifying that installer of the metal roof system has met all of the criteria outlined in "1.02 C. Installer's qualifications" and is an authorized installer certified by the manufacturer. 2. Submit the formal syllabus for the classroom and hands-on training. 3. Submit five references from five different architects or building owners for projects that have been in service for a minimum of two years, stating satisfactory performance by the installation contractor PRODUCT DELIVERY, STORAGE, AND HANDLING A. Delivery: 1. Deliver metal roof system to job site properly packaged to provide protection against transportation damage. B. Handling: 2. Exercise extreme care in unloading, storing and erecting metal roof system to prevent bending, warping, twisting and surface damage. C. Storage: 1. Store bundled sheets off the ground sufficiently high enough to allow air circulation beneath bundle and to prevent rising water from entering bundle. Slightly elevate one end of bundle. Prevent rain from entering bundle by covering with tarpaulin, making provision for air circulation between draped edges of tarpaulin and the ground. Prolonged Storage of sheets in a bundle is not recommended. If conditions do not permit immediate erection, extra care should be taken to protect sheets from staining or water marks WEATHERTIGHTNESS WARRANTY A. The Contractor shall provide to the Owner, a single source or Standard warranty signed by the roofing manufacturer of the Standing Seam Roof System as outlined below: (# Choose Single Source or Standard Entire Section) SECTION Metal Roofing B. Single Source Warranty: 1. For a period of [#choose one: twenty (20), fifteen (15), ten (10), or five (5)] years from the date of substantial completion, the roofing manufacturer WARRANTS to the Building Owner ("Owner"): to furnish roof panels, flashing and related items used to fasten the roof panels and flashing including roof jack and curb attachments to the roof structure, will not allow intrusion of water from the exterior of the roofing manufacturer's Roof System into the building envelope when exposed to ordinary weather conditions and ordinary wear and usage. The Date of substantial completion is the date that is certified by the Architect, Owner, or Owner's Representative, when the roofing manufacturer's Roofing System is completed and accepted by or on behalf of the Owner. 2. Manufacturer's Field Service: a. During installation, provide for two on-site inspections of roof application by qualified technical representative of the manufacturer. b. Upon completion of installation, provide final inspection by a technical representative of roofing manufacturer to confirm that roofing system has been installed in accordance with manufacturer's requirements. 3. The roofing manufacturer shall have the SOLE AND EXCLUSIVE obligation for all warranty work commencing on the date of substantial completion and under all circumstances terminates on the [# insert appropriate number of years] year anniversary of the date certified as Substantial Completion of the roofing manufacturer's Roof System. During the period in which the roofing manufacturer has any warranty obligation, the roofing manufacturer shall take appropriate actions necessary to cause the non-performing portions of the Roof System to perform their proper functions. ROOFING MANUFACTURER'S LIABILITY: 4. The total liability of the roofing manufacturer under Single Source warranty is (# choose one), a. Single Source I, limited solely to two (2) times the cost of the roofing manufacturer's Roof System as invoiced to the roofing manufacturer's customer. b. Single Source II, limited solely to four (4) times the cost of the roofing manufacturer's Roof System as invoiced to the roofing manufacturer's customer. c. Single Source III, a no dollar limit of the manufacturers Roof System as invoiced to the roofing manufacturer's customer. CB-10 SUBJECT TO CHANGE WITHOUT NOTICE SEE FOR CURRENT INFORMATION EFFECTIVE MAY 15, 2014
13 C. Standard Warranty: 1. For a period of [#choose one: twenty (20), fifteen (15), ten (10), or five (5)] years from the date of substantial completion, the roofing manufacturer WARRANTS to the Building Owner ("Owner"): that the roofing manufacturer's furnished roof panels, flashing, and related items used to fasten the roof panels and flashing to the roof structure ("Roof System") will not allow intrusion of water from the exterior of the roofing manufacturer's Roof System into the building envelope, when exposed to ordinary weather conditions and ordinary wear and usage. The Date of substantial completion is the date that is certified by the Architect, Owner, or Owner's Representative, when the roofing manufacturer's Roofing System is completed and accepted by or on behalf of the Owner. 2. The Roofing Installer shall have the sole and exclusive obligation for all warranty work commencing on the date of substantial completion up to and until the roof system has performed leak free for (24) consecutive months. The sole and exclusive obligation for all warranty work commencing on the date the roof has been leak free for (24) consecutive months and under all circumstances terminates on the [# insert # of years]. anniversary of the date certified as substantial completion of the roofing manufacturers roof system. ROOFING MANUFACTURER'S LIABILITY: 3. The total liability of the roofing manufacturer under Standard warranty is [# choose one:] a. Standard I, Limited solely to $.20 sq. ft. of the actual roof area b. Standard II, limited solely to the Invoice Amount for the roof system (panels, fasteners, trim and accessories) to its customer. (No structural material, freight or taxes included) c. Standard III, a no dollar limit of the manufacturers Roof System as invoiced to the roofing manufacturers customer. Standard III is the only standard warranty that requires a certified installer on the job site at all times. PART 2 - PRODUCTS architectural structural standing seam metal roof system. SECTION Metal Roofing SPECIFICATIONS 2.01 MATERIALS A. Metal roof system profile: 1. 2 inch high x 3/4" inch wide rib x 16 inch wide, striated panel with 2 pencil ribs, 1 1/2" from each vertical leg of panel. B. Metal roof system style: 1. Vertical leg, concealed fastener, standing seam, utilizing male and female rib configurations, continuously locked together by an electrically powered mechanical seaming device during installation. C. Gauge: gauge (UL 90 rated). D. Substrate: 1. Galvalume steel sheet, minimum yield of 50,000 PSI. E. Clip: [# choose one] 1. One piece fixed clip, 22 gauge, with factory-applied mastic (# UL-90 rated - Underwriters Laboratories). 2. Two piece floating clip, 18 gauge base, 24 gauge top, with factory applied mastic (# UL-90 rated - Underwriters Laboratories). 3. Utility clip, 24 gauge, with factory-applied mastic. F. Texture: [# choose one] 1. Smooth with striations. G. Finish: [# choose one] 1. Signature 200 Premium thermoset silicone polyester (20 year warranty). 2. Signature 300 Premium fluorocarbon coating produced with Kynar 500 or Hylar 5000 resin (20 year warranty). 3. Bare Galvalume Plus (20 year warranty). H. Color: 1. Selected from Energy Starâ Rated metal roof system manufacturer's standard offering. I. Acceptable manufacturer: 1. MBCI - Houston, TX - (281) a. #Insert: Architect's (owner's) method of approval of "or equals". J. Other manufacturers desiring approval comply with Section K. Prefabricated Roof Jacks: 1. SFS - intech - Wyomissing, PA. 2. ITW Buildex - Itasca, IL MISCELLANEOUS MATERIALS A. Fasteners: 1. All self-tapping/self-drilling fasteners, bolts, nuts, self-locking rivets and other suitable fasteners shall be designed to withstand specified design loads. 2. Use long life fasteners for all interior and exterior metal roof system applications. 3. Provide fasteners with a factory applied coating in a color to match metal roof system application. 4. Provide neoprene washers under heads of exposed fasteners. 5. Locate and space all exposed fasteners in a true vertical and horizontal alignment. Use proper torque settings to obtain controlled uniform compression for a positive seal without rupturing the neoprene washer. EFFECTIVE MAY 15, 2014 SEE FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE CB-11
14 SPECIFICATIONS SECTION Metal Roofing B. Accessories: 1. Provide all components required per the metal roof system manufacturer's approved shop drawings for a complete metal roof system to include panels, panel clips, trim/flashing, fascias, ridge, closures, sealants, fillers and any other required items. a. All outside closures will be fabricated from Galvalume Plus sheet steel of the same gauge, finish and color as the panels. b. All tape seal is to be a pressure sensitive, 100 percent solids, polyisobutylene compound sealing tape with a release paper backing. Provide permanently elastic, non-sagging, nontoxic, non-staining tape seal approved by the metal roof system manufacturer. c. All tube sealant is to be a one-part elastomeric polyurethane sealant approved by the metal roof system manufacturer FABRICATION A. Material shall be in-line leveled prior to roll forming the panel profile. B. Where possible, roll form panels in continuous lengths, full length of detailed runs. C. Standard panel length shall be no more than 50 feet long (for longer length availability, contact manufacturer). D. Fabricate trim/flashing and accessories to detailed profiles. E. Fabricate trim/flashing from same material as panel. F. Panels may be curved at the plant location or in the field PREFABRICATED ROOF JACKS A. Pipe flashings shall be a one piece [# choose one: EPDM (ethylene propylene diene monomer) molded rubber boot having a serviceable temperature range of -65 F to 212 F (for standard applications) or silicone molded rubber boot having a serviceable temperature range of -100 F to 437 F (for high temperature applications)] and shall be resistant to ozone and ultraviolet rays. Units shall have an aluminum flanged base ring. Do not install pipe flashings through any panel seams - install ONLY in the flat portion of the panel. PART 3 - EXECUTION 3.01 SURFACE CONDITIONS A. Examination: 1. Inspect installed work of other trades and verify that such work is complete to a point where this work may continue. 2. Verify that installation may be made in accordance with approved shop drawings and manufacturer's instructions. This specifically includes verifying that secondary structural members and/or decking are installed to meet UL and building code requirements. Coordinate with metal roof system manufacturer to insure that reduced clip spacings at eave, rake, ridge and corner areas are accommodated. B. Discrepancies: 1. In event of discrepancy, notify the architect (owner). 2. Do not proceed with installation until discrepancies have been resolved FABRICATION A. Install metal roof system so that it is weathertight, without waves, warps, buckles, fastening stresses or distortion, allowing for expansion and contraction. B. Install metal roof system in accordance with manufacturer's instructions and shop drawings. C. Provide concealed anchors at all panel attachment locations. D. Install panels plumb, level and straight with seams and ribs parallel, conforming to design as indicated CLEANING, PROTECTION A. Dispose of excess materials and remove debris from site. B. Clean work in accordance with manufacturer's recommendations. C. Protect work against damage until final acceptance. Replace or repair to the satisfaction of the architect (owner), any work that becomes damaged prior to final acceptance. D. Touch up minor scratches and abrasions with touch up paint supplied by the metal roof system manufacturer. E. Do not allow panels or trim to come in contact with dissimilar metals such as copper, lead or graphite. Water run-off from these materials is also prohibited. This specifically includes condensate from roof top units. A/C units. END OF SECTION DISCLAIMER: MBCI makes no warranty, express or implied, as to the merchantability or fitness for any particular purpose of any product by an optional manufacturer. If you choose to use a product not manufactured by an optional manufacturer, as defined herein, you take the product as is and at your own risk. Descriptions and specifications contained herein were in effect at the time this publication was approved for printing. MBCI reserves the right to discontinue products at any time or change specifications and/or designs without notice and without incurring obligation. To ensure you have the latest information available, please contact MBCI or visit our web site at CB-12 SUBJECT TO CHANGE WITHOUT NOTICE SEE FOR CURRENT INFORMATION EFFECTIVE MAY 15, 2014
15 GENERAL INFORMATION, 16 wide PRODUCT CHECKLIST Back-up Plate, 16 wide For use at high eave and endlaps Prepunched 16 gauge red oxide 16 wide HW 7766 SuperLok Clip, Floating Low For use with or without ³ ₈ thermal spacer Rake Support 2³ ₈" 20-0 length 14 gauge red oxide Factory slots Field curved or kerfed Low High For use with ³ ₈, ⁵ ₈ or 1 thermal spacer Low 3¹ ₂" 3" ⁷ ₈ 2 " High Low - HW 7712 High - HW 7722 High SuperLok Clip, Fixed Low High Low High Low - HW 230 High - HW 232 For use with or without ³ ₈ thermal spacer For use with ³ ₈, ⁵ ₈ or 1 thermal spacer Low - HW 236 High - HW 234 Rake Support Bearing Plate Standard Utility 20-0 length 14 gauge red oxide Factory slots Field curved or kerfed For use with utility clip Utility HW gauge red oxide For use over rigid insulation SuperLok Clip, Utility HW 7500 For applications that do not require the clearance provided by the low and high clips. Outside Closure Standard, 16 wide HW 238 HW 440 EFFECTIVE MAY 15, 2014 SEE FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE CB-13
16 GENERAL INFORMATION PRODUCT CHECKLIST Fastener #1A Clip to purlin Fastener #1E Panel to eave plate or eave strut Rake trim to roof panel Standard endlaps (open framing) Panel to valley plate X 1 Self Driller ⁵ ₁₆ Hex Washer Head, with no washer ¹ ₄ - 14 x 1¹ ₄ Long Life Driller ⁵ ₁₆ Hex Washer Head, with sealing washer Fastener #2A Use in place of fasteners #1E and #4 at all stripouts Fastener #4 High eave and other flashing to outside closure Gutter to panel Gutter to strap Trim to trim connections 17 x 1 Long Life AB ⁵ ₁₆ Hex Washer Head, with sealing washer ¹ ₄-14 x ⁷ ₈ Long Life Lap TEK Driller ⁵ ₁₆ Hex Washer Head, with sealing washer Fastener #5 Rake support to purlin Floating eave plate to eave strut Fastener #11 Special application fastener For use on masonry ¹ ₄"-14 x 1¹ ₄" Shoulder Tek 3 ¹ ₄ X 1¹ ₄ Nail Drive Masonry Anchor Fastener #12 Utility clip to purlin Offset cleat to valley support plate or eave strut Rake angle to purlin Fastener #13 Clip to wood deck 10 x 1 #2 Phillips Pancake Head Self Driller 10 x 1 Type A #2 Phillips Pancake Head CB-14 SUBJECT TO CHANGE WITHOUT NOTICE SEE FOR CURRENT INFORMATION EFFECTIVE MAY 15, 2014
17 Fastener #14 Pop Rivet ¹ ₈ diameter x ³ ₁₆ grip range Trim to trim connections Stainless steel PRODUCT CHECKLIST GENERAL INFORMATION Fastener #15B 14 X 2⁷ ₈ Deck Screw Driller #3 Phillips Truss Head For clip attachment in a composite roof assembly Fastens clip and bearing plate to metal deck in rigid board insulation over metal deck applications Length to be determined by insulation thickness and metal deck depth Fastener #15C For clip attachment in a composite roof assembly Fastens clip and bearing plate to metal deck in rigid board insulation over metal deck applications Length to be determined by insulation thickness and metal deck depth Fastener #17 Outside closure to panel at high eave (with back-up plate) 14 X 4¹ ₂ Deck Screw Driller #3 Phillips Truss Head Tri-Bead Tape Sealer ³ ₁₆ x ⁷ ₈ x 25 Triple-Bead Tape Sealer For use at trim connections Tri-Bead HW 504 For use at endlaps X 1 Self Driller ⁵ ₁₆ Hex Washer Head, with ⁵ ₈ O.D. washer Fastener #18 Clip to plywood Eave plate to plywood Outside closure to panel at high eave (with plywood) ³ ₁₆ x 2¹ ₂ x 20 Caulk, Urethane Triple-Bead HW 502 Paintable 14 X 1 Type A ⁵ ₁₆ Hex Head, with ⁵ ₈ O.D. washer Eave Plate, High Caulk Panel Hemming Tool HW 602 HW 7616 EFFECTIVE MAY 15, 2014 SEE FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE CB-15
18 GENERAL INFORMATION PRODUCT CHECKLIST Box Gutter Gutter Strap 24 Gauge Material Specify Roof Pitch T Gauge Material Gutter Strap FL-310 Box High Side Eave Trim Eave W/Extended Drip Edge Flash Specify roof pitch 24 Gauge material Specify open hem when using with continuous cleat T Gauge Material T-5151 Parapet High Side Eave Flash Low System Extended Valley Flash 24 Gauge Material FL Gauge Material FL-711 Counter Flash High System Extended Valley Flash 24 Gauge Material FL Gauge Material FL-715 CB-16 SUBJECT TO CHANGE WITHOUT NOTICE SEE FOR CURRENT INFORMATION EFFECTIVE MAY 15, 2014
19 GENERAL INFORMATION PRODUCT CHECKLIST Curved Variable Termination Trim Curved Counter Flash 6" (Not Pre-Curved) 24 Gauge Material 10'-2" FL '-2" FL Gauge Material Please Inquire Curved Parapet Rake Flash Curved Rake Clip 24 Gauge Material Please Inquire (Not Pre-Curved) 24 Gauge Material FL-378 Curved Rake Cleat Curved Rake Trim 24 Gauge Material Please Inquire 24 Gauge Material Please Inquire EFFECTIVE MAY 15, 2014 SEE FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE CB-17
20 GENERAL INFORMATION PREPARATORY REQUIREMENTS 1. MBCI has field seaming kits available for installation of the roof system. To reserve a kit, please complete a Seaming Tool Rental Agreement and return it to your MBCI representative. This form should be submitted as soon as possible to ensure kit availability. Other types of field seaming machines may seam the MBCI panels. However, MBCI cannot be held responsible for any wind uplift resistance or for damage when another type of field seamer is used. 2. When installing over open framing, a curved angle or other member must be installed at each rake to allow the beginning and finishing panels to be fastened at 2-0 centers max. Extreme wind conditions may require fastening at closer centers. 3. Check the radius of the substructure in several places. Installing panels curved to a radius different from the substructure may cause oil canning. Any deviations in the substructure will telegraph through to the panels which may cause oil canning or other distortions. 4. It is critical that the purlins or bar joists at the ridge and endlaps be located exactly as detailed and that they are straight from rafter to rafter. Any mislocation or bowing of these members can cause the fasteners at the ridge or endlaps to foul as the panels expand and contract. 5. Curved panels do not have factory mastic in the sidelap. The roof installer must field apply ¹ ₂ x ³ ₃₂ tape sealer to the male leg of each panel as they are being installed. 6. When panels are to be curved on site, the following must be provided: Manpower to handle panels at the in-feed and out-feed of curving. Number of personnel required will be determined by panel length. Panels can be curved at approximately 30' per minute if bundles are close to curving machine and adequate personnel are available. 115 volt power supply within 50 of curving operation. Equipment to unload the panels and curving equipment and to hoist curved panels onto the roof. A level surface or platform on which to perform the curving operation. 7. Keep panels clean and dry. Any dirt or debris must be removed from panels before curving. 8. If the curved panels are not immediately used, it is the installer s responsibility to properly secure and store the panels to prevent damage. 9. On projects with both straight and curved panels, make sure the panels that are to be field curved are not used on a straight area of the roof. The panels to be field curved are different from panels used in straight applications. Panels that are to be field curved will have a label on the bundle identifying them as For Curving Only. CAUTION Application and design details are for illustration purposes only, and may not be appropriate for all environmental conditions or buildings designs. Projects should be engineered to conform to applicable building codes, regulations, and accepted industry practices. CB-18 SUBJECT TO CHANGE WITHOUT NOTICE SEE FOR CURRENT INFORMATION EFFECTIVE MAY 15, 2014
21 GENERAL INFORMATION UNLOADING Upon receiving material, check shipment against shipping list for shortages and damages. The manufacturer will not be responsible for shortages or damages unless they are noted on the shipping list. Each bundle should be lifted at its center of gravity. Where possible, bundles should remain banded until final placement on roof. If bundles must be opened, they should be retied before lifting. When lifting bundles with a forklift, forks must be a minimum of five feet apart. Do not transport open bundles. Drive slowly when crossing rough terrain to prevent panel buckling. On projects with both straight and curved panels, store curved panels separately. Panel bundles that are to be field curved will be marked with a blue label stating: These Panels are for Field Curving Only CAUTION Improper unloading and handling of bundles and crates may cause bodily injury or material damage. The manufacturer is not responsible for bodily injuries or material damages during unloading and storage. EFFECTIVE MAY 15, 2014 SEE FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE CB-19
22 GENERAL INFORMATION HANDLING/ PANEL STORAGE Standing on one side of the panel, lift it by the seam. If the panel is over 10 long, lift it with two or more people on one side of the panel to prevent buckling. Do not pick panels up by the ends. NOTE Protective gloves should always be used while handling panels. OSHA safety regulations must be followed at all times. Store bundled sheets off the ground sufficiently high to allow air circulation beneath bundle and to prevent rising water from entering bundle. Slightly elevate one end of bundle. Prevent rain from entering bundle by covering with a tarp, making provision for air circulation between draped edges of tarp and the ground. PROLONGED STORAGE OF SHEETS IN A BUNDLE IS NOT RECOMMENDED. If conditions do not permit immediate erection, extra care should be taken to protect sheets from water damage. Check to see that moisture has not formed inside the bundles during shipment. If moisture is present, panels should be uncrated and wiped dry, then restacked and loosely covered so that air can circulate between the panels. CB-20 SUBJECT TO CHANGE WITHOUT NOTICE SEE FOR CURRENT INFORMATION EFFECTIVE MAY 15, 2014
23 INSTALLATION RECOMMENDED INSTALLATION TECHNIQUES clips are supplied with factory applied mastic. If a clip must be removed from the panel, check factory mastic - if damaged, replace with a bead of urethane sealant. Seal panel sidelaps by applying a piece of ¹ ₂ x ³ ₃₂ tape sealer along the top of the male leg for the length of the panel before the next panel is installed. As panels are installed, hand seam at each clip with hand tool. Panels should be completely seamed with electric seamer as soon after installation as possible. Refer to pages CB-55 through CB-56 for seaming information. Seal panel seams at eave and valleys with urethane sealant. EFFECTIVE MAY 15, 2014 SEE FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE CB-21
24 GENERAL INFORMATION RECOMMENDED INSTALLATION TECHNIQUES (Continued) When installing clips, be sure to push them tight to the panel before installing fasteners. If you leave a gap between the clip and the panel, it will affect panel module. Before installing clips to second and all following panels, "C" clamp the panel seam at both ends. Long panels may require one or more "C" clamps in the middle. This will help hold panel module. Never install plumbing vent pipes through the panel seam. Always install in the pan of panel. CB-22 SUBJECT TO CHANGE WITHOUT NOTICE SEE FOR CURRENT INFORMATION EFFECTIVE MAY 15, 2014
25 DESIGN TYPICAL DETAILS OUTSIDE CLOSURE NOTES 1. Panels must be seamed before the outside closures are installed. Do not seam the first 9 of panel at the ridge with the electric seamer. This will allow the panel seams to be properly sealed as outlined in the following steps. 2. At the ridge, fill the inside cavity of the panel seam with Tri-Bead tape sealer. This should be done for the first two inches of seam only. 3. Using the hand crimper, crimp the remaining 9 of seam. If needed, "duck bills" may be used to further flatten the seam in Step 2. This will force the Tri-Bead tape sealer into all voids. Excess sealant will be forced out the below the seam. 4. Install Tri-Bead tape sealer across width of panel. Center of tape sealer should be 1¹ ₂ from end of panel. Begin tape sealer at top of seam. Roll tape sealer under seam, sealing to the excess urethane sealant forced from seam in Step 3. Tape sealer will continue down seam, across width of panel, up to and across the top of the adjacent seam. Field cut the end of the outside closure that accepts the seam of the panel. Cut the top leg off even with the tab on the end of the closure. Notch and bend the vertical leg of the closure, above the tab, back to the dimple formed into the closure. 5. Install first outside closure. Attach to panel with Fastener #17 at all prepunched holes. Vertical leg of outside closure should be 2 from end of panel. 6. Install Tri-Bead tape sealer across top leg of first outside closure where it laps over seam and continue tape sealer across next panel as outlined in Step 4. Field cut and install next and all subsequent outside closures as outlined in Steps 4 and 5. EFFECTIVE MAY 15, 2014 SEE FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE CB-23
26 DESIGN TYPICAL DETAILS FIELD HEMMING PANEL ENDS NOTES 1. Field notch male and female legs of panel 1¹ ₂. 2. Flatten beads with "duck bills". 3. Engage panel hemming tool onto protruding pan of panel. 4. Bend pan of panel down to form an open hem. 5. Hem may be tightened with a pair of duck bills. CB-24 SUBJECT TO CHANGE WITHOUT NOTICE SEE FOR CURRENT INFORMATION EFFECTIVE MAY 15, 2014
27 DESIGN OVER PLYWOOD SINGLE PANEL CONFIGURATION LOW SYSTEM ONLY HIGH EAVE SINGLE OR MULTIPLE PANEL CONFIGURATION LOW OR HIGH SYSTEM MULTIPLE PANEL CONFIGURATION HIGH SYSTEM ONLY EFFECTIVE MAY 15, 2014 SEE FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE CB-25
28 WOOD DECK EAVE TRIM LOW SYSTEM HIGH SYSTEM NOTES 1. A clip must be installed within 12" of the panel ends. 2. Install the eave trim with drip edge to the wood deck with Fastener #13 at 1'-0" o.c. (Low Systems) or to the High Eave Plate with Fastener #12 at 1-0 o.c. (High Systems). 3. To field hem panels, see page CB See Panel End Sealant Detail At Eave on page CB-21 to seal panel ends. CB-26 SUBJECT TO CHANGE WITHOUT NOTICE SEE FOR CURRENT INFORMATION EFFECTIVE MAY 15, 2014
29 WOOD DECK EAVE WITH GUTTER LOW SYSTEM HIGH SYSTEM NOTES 1. A clip must be installed within 12" of the panel ends. 2. Install the gutter with drip edge to the wood deck with Fastener #13 at 1'-0" o.c. (Low Systems) or to the High Eave Plate with Fastener #12 at 1-0 o.c. (High Systems). 3. To field hem panels, see page CB See Panel End Sealant Detail At Eave on page CB-21 to seal panel ends. EFFECTIVE MAY 15, 2014 SEE FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE CB-27
30 WOOD DECK VALLEY NOTES 1. Install a 3-0 wide waterproof peel and stick membrane to the deck at the valley. 2. Length of valley trim segments are dependant upon roof radius. Lap valley trim segments 4-6. Apply two ¹ ₄ beads of urethane sealant between the valley trim pieces. 3. Mark panel line on valley trim. The curvature of this line is dependent upon roof radius. Install offset cleat segments in lengths dictated by curved line on valley trim. Tri-Bead Tape Sealer is to be installed under bottom leg of offset cleat. Attach offset cleat to deck with Fastener #13 at 6 o.c.. 4. To field hem panels, see page CB See Panel End Sealant Detail At Eave on page CB-21 to seal panel ends. CB-28 SUBJECT TO CHANGE WITHOUT NOTICE SEE FOR CURRENT INFORMATION EFFECTIVE MAY 15, 2014
31 WOOD DECK ENDLAP NOTES 1. The panel endlap is Install a Back-Up Plate onto the end of the lower panel. Apply Triple Bead Tape Sealer across the entire width of the lower panel. The upslope edge of the Triple Bead Tape Sealer will be 2¹ ₂" from the lower panel end. 3. Apply a 2¹ ₂" piece of Tri-Bead Tape Sealer to the top of the male leg on the upper panel. The down slope edge of the Tri-Bead Tape Sealer will be 3¹ ₂" from the end of the upper panel. Install upper panel onto lower panel and fasten endlap together with Fastener #1E in the proper sequence. EFFECTIVE MAY 15, 2014 SEE FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE CB-29
32 WOOD DECK RAKE BEGINNING/FINISHING ON MODULE NOTES 1. Install field curved or kerfed rake support to wood deck with Fastener #13 at 24 o.c. 2. Apply Tri-Bead Tape Sealer to vertical leg of panel and install Curved Parapet Rake Cleat to panel with Fastener #1E at 24 o.c. 3. Install a 2" long piece of Curved Rake Clip 12" o.c. to wall with (2) Fastener #12. Hand Tong Cleat Closer after installation. 4. Apply Tri-Bead Tape Sealer to top of Curved Parapet Rake Cleat and install Curved Rake Trim with Fastener #14A at 6 o.c. 5. If last panel finishes more than 5 away from outside of wall, see Finishing Rake details on Page CB-31. CB-30 SUBJECT TO CHANGE WITHOUT NOTICE SEE FOR CURRENT INFORMATION EFFECTIVE MAY 15, 2014
33 WOOD DECK RAKE FINISHING OFF MODULE NOTES FINISHING DIMENSION 15 ³ ₄" - 8" 1. Install field curved or kerfed rake support to wood deck with Fastener #13 at 24 o.c. 2. Field cut last panel and bend up a 1 leg. Apply Tri-Bead Tape Sealer to 1 leg. 3. Install male leg cut from a curved panel to the 1 leg of the last panel. Attach with Fastener #1E at 12 o.c. Fastener must go through tape sealer. 4. Apply Tri-Bead Tape Sealer to top of male leg and install Curved Rake Trim with Fastener #14A at 12 o.c. FINISHING DIMENSION 7 ³ ₄" - 5 ¹ ₄" 1. Install clips to last panel as normal and apply Tri-Bead Tape Sealer continuous to top of male leg. 2. Install ³ ₈" x 6" long plywood spacer strip along rake edge of deck. 3. Cut female leg from curved panel and install on top of plywood spacer strip with Fastener #18 at 24" o.c. 4. Attach Curved Rake Trim to top of cut female leg with Fastener #14 (2 per trim piece). 5. Apply Tri-Bead Tape Sealer to top of Curved Rake Trim, directly in line with the female panel leg. Install Variable Termination Trim with Fastener #4 at 12" o.c. at the attachment to the male leg of the last panel and 6" o.c. at the attachment to the Variable Termination Trim. EFFECTIVE MAY 15, 2014 SEE FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE CB-31
34 WOOD DECK HIGH EAVE LOW SYSTEM HIGH SYSTEM NOTES LOW SYSTEM 1. To support the panel at the high eave, install a ³ ₈ x 6 wide plywood spacer strip. 2. Install outside closures as shown on page CB-23 with Fastener # Apply Tri-Bead Tape Sealer to top leg of outside closures and install High Eave Trim with Fastener #14A at 6 o.c. HIGH SYSTEM 1. To support the panel at the high eave, install a High Eave Plate with Fastener #18 at 12 o.c.. 2. Install outside closures as shown on page CB-23 with Fastener # Apply Tri-Bead Tape Sealer to top leg of outside closures and install High Eave Trim with Fastener #14A at 6 o.c. CB-32 SUBJECT TO CHANGE WITHOUT NOTICE SEE FOR CURRENT INFORMATION EFFECTIVE MAY 15, 2014
35 WOOD DECK PARAPET HIGH EAVE LOW SYSTEM HIGH SYSTEM NOTES LOW SYSTEM 1. To support the panel at the parapet high eave, install a ³ ₈ x 6 wide plywood spacer strip. 2. Install outside closures as shown on page CB-23 with Fastener # Apply Tri-Bead Tape Sealer to top leg of outside closures and install Parapet High Eave Trim with Fastener #14A at 6 o.c. HIGH SYSTEM 1. To support the panel at the parapet high eave, install a High Eave Plate with Fastener #18 at 12 o.c.. 2. Install outside closures as shown on page CB-23 with Fastener # Apply Tri-Bead Tape Sealer to top leg of outside closures and install Parapet High Eave Trim with Fastener #14A at 6 o.c. EFFECTIVE MAY 15, 2014 SEE FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE CB-33
36 WOOD DECK PARAPET RAKE BEGINNING/FINISHING ON MODULE MASONRY PARAPET WALL PANEL OR EIFS SYSTEM PARAPET NOTES 1. Install clips to last panel as normal and apply Tri-Bead Tape Sealer, continuous, to top of male leg. 2. Install EPDM membrane over male leg and up the side of the parapet wall. Tri-Bead Tape Sealer must be applied to both sides of the EPDM membrane at both the male leg and the parapet wall. 3. Install Curved Parapet Rake Trim to the male leg of the last panel with Fastener #4 at 12 o.c. CB-34 SUBJECT TO CHANGE WITHOUT NOTICE SEE FOR CURRENT INFORMATION EFFECTIVE MAY 15, 2014
37 WOOD DECK PARAPET RAKE CONTINUED FINISHING ON MODULE NOTES FINISHING DIMENSION 5 ¹ ₄" - 7 ³ ₄" 1. Install clips to last panel as normal and apply Tri-Bead Tape Sealer continuous to top of male leg. 2. Install ³ ₈" x 6" long plywood spacer strip along rake edge of deck. 3. Cut female leg from curved panel and install on top of plywood spacer strip with Fastener #18 at 24" o.c. 4. Attach Curved Parapet Rake Trim to top of cut female leg with Fastener #14 (2 per trim piece). 5. Apply Tri-Bead Tape Sealer to top of Curved Parapet Rake Trim, directly in line with the female panel leg. Install Variable Termination Trim with Fastener #4 at 12" o.c. at the attachment to the male leg of the last panel and 6" o.c. at the attachment to the Variable Termination Trim. FINISHING DIMENSION 8" - 17 ³ ₄" 1. Install field curved rake support to wood deck with Fastener #13 at 24 o.c. 2. Field cut last panel and bend up a 1" leg. Apply Tri-Bead Tape Sealer to 1" leg. 3. Install male leg cut from a curved panel to the 1" leg of the last panel. Attach with Fastener #1E at 12" o.c. Fastener must go through tape sealer. 4. Apply Tri-Bead Tape Sealer to top of male leg and install Curved Parapet Rake Trim with Fastener #4 at 12" o.c. EFFECTIVE MAY 15, 2014 SEE FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE CB-35
38 METAL DECK WITH RIGID INSULATION EAVE TRIM LOW SYSTEM HIGH SYSTEM NOTES 1. A clip must be installed within 12" of the panel ends. 2. Install the eave trim with drip edge to the wood blocking with Fastener #13 at 1'-0" o.c. (Low Systems) or to the High Eave Plate with Fastener #12 at 1-0 o.c. (High Systems). 3. To field hem panels, see page CB See Panel End Sealant Detail At Eave on page CB-21 to seal panel ends. CB-36 SUBJECT TO CHANGE WITHOUT NOTICE SEE FOR CURRENT INFORMATION EFFECTIVE MAY 15, 2014
39 METAL DECK WITH RIGID INSULATION EAVE WITH GUTTER LOW SYSTEM HIGH SYSTEM NOTES 1. A clip must be installed within 12" of the panel ends. 2. Install the gutter with drip edge to the wood blocking with Fastener #13 at 1'-0" o.c. (Low Systems) or to the High Eave Plate with Fastener #12 at 1-0 o.c. (High Systems). 3. To field hem panels, see page CB See Panel End Sealant Detail At Eave on page CB-21 to seal panel ends. EFFECTIVE MAY 15, 2014 SEE FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE CB-37
40 METAL DECK WITH RIGID INSULATION VALLEY NOTES 1. Install a 3-0 wide waterproof peel and stick membrane to the Rigid Insulation at the valley. 2. Length of valley trim segments is dependant upon roof radius. Lap valley trim segments 4-6. Apply two ¹ ₄ beads of urethane sealant between the valley trim pieces. 3. Mark panel line on valley trim. The curvature of this line is dependent upon roof radius. Install offset cleat segments in lengths dictated by curved line on valley trim. Tri-Bead Tape Sealer is to be installed under bottom leg of offset cleat. Attach offset cleat to deck with Fastener #13 at 6 o.c.. 4. To field hem panels, see page CB See Panel End Sealant Detail At Eave on page CB-21 to seal panel ends. CB-38 SUBJECT TO CHANGE WITHOUT NOTICE SEE FOR CURRENT INFORMATION EFFECTIVE MAY 15, 2014
41 METAL DECK WITH RIGID INSULATION ENDLAP NOTES 1. Panel endlap is 6 with prepunched holes in the top panel 3" from the end. 2. Install a Back-Up Plate onto the end of the lower panel. Apply Triple Bead Tape Sealer across the entire width of the panel. The down slope edge of the Triple Bead Tape Sealer will be 5" from the panel end. 3. Apply a 6" piece of Tri-Bead Tape Sealer to the top of the male leg on the upper panel. Install upper panel onto lower panel and fasten endlap together with Fastener #1E in the proper sequence. EFFECTIVE MAY 15, 2014 SEE FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE CB-39
42 METAL DECK WITH RIGID INSULATION RAKE BEGINNING/FINISHING ON MODULE NOTES 1. Install field curved or kerfed rake support over Rigid Insulation and Bearing Plate with Fastener #5 at 24 o.c. 2. Apply Tri-Bead Tape Sealer to vertical leg of panel and install Curved Parapet Rake Cleat to panel with Fastener #1E at 24 o.c. 3. Install a 2" long piece of Curved Rake Clip 12" o.c. to wall with (2) Fastener #12. Hand Tong Cleat Closer after installation. 4. Apply Tri-Bead Tape Sealer to top of Curved Parapet Rake Cleat and install Curved Rake Trim with Fastener #14A at 6 o.c. 5. If last panel finishes more than 5 away from outside of wall, see Finishing Rake details on Page CB-41. CB-40 SUBJECT TO CHANGE WITHOUT NOTICE SEE FOR CURRENT INFORMATION EFFECTIVE MAY 15, 2014
43 METAL DECK WITH RIGID INSULATION RAKE FINISHING OFF MODULE NOTES FINISHING DIMENSION 15 ³ ₄" - 8" 1. Install field curved or kerfed rake support over Rigid Insulation and Bearing Plate with Fastener #13 at 24 o.c. 2. Field cut last panel and bend up a 1 leg. Apply Tri-Bead Tape Sealer to 1 leg. 3. Install male leg cut from a curved panel to the 1 leg of the last panel. Attach with Fastener #1E at 12 o.c. Fastener must go through tape sealer. 4. Apply Tri-Bead Tape Sealer to top of male leg and install Curved Rake Trim with Fastener #14A at 12 o.c. FINISHING DIMENSION 7 ³ ₄" - 5 ¹ ₄" 1. Install clips to last panel as normal and apply Tri-Bead Tape Sealer continuous to top of male leg. 2. Install ³ ₈" x 6" long plywood spacer strip along rake edge of deck. 3. Cut female leg from curved panel and install on top of plywood spacer strip with Fastener #15C at 24" o.c. 4. Attach Curved Rake Trim to top of cut female leg with Fastener #14 (2 per trim piece). 5. Apply Tri-Bead Tape Sealer to top of Curved Rake Trim, directly in line with the female panel leg. Install Variable Termination Trim with Fastener #4 at 12" o.c. at the attachment to the male leg of the last panel and 6" o.c. at the attachment to the Variable Termination Trim. EFFECTIVE MAY 15, 2014 SEE FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE CB-41
44 METAL DECK WITH RIGID INSULATION HIGH EAVE LOW SYSTEM HIGH SYSTEM NOTES LOW SYSTEM 1. To support the panel at the high eave, install a ³ ₈ x 6 wide plywood spacer strip. 2. Install outside closures as shown on page CB-23 with Fastener # Apply Tri-Bead Tape Sealer to top leg of outside closures and install High Eave Trim with Fastener #14A at 6 o.c. HIGH SYSTEM 1. To support the panel at the high eave, install a High Eave Plate with Fastener #18 at 12 o.c.. 2. Install outside closures as shown on page CB-23 with Fastener # Apply Tri-Bead Tape Sealer to top leg of outside closures and install High Eave Trim with Fastener #14A at 6 o.c. CB-42 SUBJECT TO CHANGE WITHOUT NOTICE SEE FOR CURRENT INFORMATION EFFECTIVE MAY 15, 2014
45 METAL DECK WITH RIGID INSULATION PARAPET HIGH EAVE LOW SYSTEM HIGH SYSTEM NOTES LOW SYSTEM 1. To support the panel at the parapet high eave, install a ³ ₈ x 6 wide plywood spacer strip. 2. Install outside closures as shown on page CB-23 with Fastener # Apply Tri-Bead Tape Sealer to top leg of outside closures and install Parapet High Eave Trim with Fastener #14A at 6 o.c. HIGH SYSTEM 1. To support the panel at the parapet high eave, install a High Eave Plate with Fastener #18 at 12 o.c.. 2. Install outside closures as shown on page CB-23 with Fastener # Apply Tri-Bead Tape Sealer to top leg of outside closures and install Parapet High Eave Trim with Fastener #14A at 6 o.c. EFFECTIVE MAY 15, 2014 SEE FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE CB-43
46 METAL DECK WITH RIGID INSULATION PARAPET RAKE BEGINNING/FINISHING ON MODULE MASONRY PARAPET WALL PANEL OR EIFS SYSTEM PARAPET NOTES 1. Install clips to last panel as normal and apply Tri-Bead Tape Sealer, continuous, to top of male leg. 2. Install EPDM membrane over male leg and up the side of the parapet wall. Tri-Bead Tape Sealer must be applied to both sides of the EPDM membrane at both the male leg and the parapet wall. 3. Install Curved Parapet Rake Trim to the male leg of the last panel with Fastener #4 at 12 o.c. and to the parapet wall with Fastener #11 at 24 o.c.. CB-44 SUBJECT TO CHANGE WITHOUT NOTICE SEE FOR CURRENT INFORMATION EFFECTIVE MAY 15, 2014
47 METAL DECK WITH RIGID INSULATION PARAPET RAKE CONTINUED FINISHING OFF MODULE NOTES FINISHING DIMENSION 5 ¹ ₄" - 7 ³ ₄" 1. Install clips to last panel as normal and apply Tri-Bead Tape Sealer continuous to top of male leg. 2. Install ³ ₈" x 6" long plywood spacer strip along rake edge of deck. 3. Cut female leg from curved panel and install on top of plywood spacer strip with Fastener #15C at 24" o.c. 4. Attach Curved Parapet Rake Trim to top of cut female leg with Fastener #14 (2 per trim piece). 5. Apply Tri-Bead Tape Sealer to top of Curved Parapet Rake Trim, directly in line with the female panel leg. Install Variable Termination Trim with Fastener #4 at 12" o.c. at the attachment to the male leg of the last panel and 6" o.c. at the attachment to the Variable Termination Trim. FINISHING DIMENSION 8" - 17 ³ ₄" 1. Install field curved or kerfed rake support over Rigid Insulation and Bearing Plate with Fastener # 15C at 24 o.c. 2. Field cut last panel and bend up a 1" leg. Apply Tri-Bead Tape Sealer to 1" leg. 3. Install male leg cut from a curved panel to the 1" leg of the last panel. Attach with Fastener #1E at 12" o.c. Fastener must go through tape sealer. 4. Apply Tri-Bead Tape Sealer to top of male leg and install Curved Parapet Rake Trim with Fastener #14 at 12" o.c. EFFECTIVE MAY 15, 2014 SEE FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE CB-45
48 OPEN FRAMING EAVE TRIM LOW SYSTEM HIGH SYSTEM NOTES 1. Install eave plate to eave strut with Fastener #17 at 1'-0" on center. 2. Install eave trim to eave plate with Fastener #12 at 1'-0" on center. 3. To field hem panels, see page CB See Panel End Sealant Detail At Eave on page CB-21 to seal panel ends. CB-46 SUBJECT TO CHANGE WITHOUT NOTICE SEE FOR CURRENT INFORMATION EFFECTIVE MAY 15, 2014
49 OPEN FRAMING EAVE WITH GUTTER LOW SYSTEM HIGH SYSTEM NOTES 1. Install eave plate to eave strut with Fastener #17 at 1'-0" on center. 2. Install eave trim to eave plate with Fastener #12 at 1'-0" on center. 3. To field hem panels, see page CB See Panel End Sealant Detail At Eave on page CB-21 to seal panel ends. EFFECTIVE MAY 15, 2014 SEE FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE CB-47
50 OPEN FRAMING ENDLAP NOTES 1. Panel endlap is 6 with prepunched holes in the top panel 3" from the end. 2. Install a Back-Up Plate onto the end of the lower panel. Apply Triple Bead Tape Sealer across the entire width of the panel. The down slope edge of the Triple Bead Tape Sealer will be 5" from the panel end. 3. Apply a 6" piece of Tri-Bead Tape Sealer to the top of the male leg on the upper panel. Install upper panel onto lower panel and fasten endlap together with Fastener #1E in the proper sequence. CB-48 SUBJECT TO CHANGE WITHOUT NOTICE SEE FOR CURRENT INFORMATION EFFECTIVE MAY 15, 2014
51 OPEN FRAMING RAKE BEGINNING/FINISHING ON MODULE NOTES 1. Install field curved rake support to field curved rake angle with Fastener #5 at 24 on center. 2. Apply Tri-Bead Tape Sealer to vertical leg of panel and install Curved Parapet Rake Cleat to panel with Fastener #1E at 24 o.c. 3. Install a 2" long piece of Curved Rake Clip 12" o.c. to wall with (2) Fastener #12. Hand Tong Cleat Closer after installation. 4. Apply Tri-Bead Tape Sealer to top of Curved Parapet Rake Cleat and install Curved Rake Trim with Fastener #14A at 6 o.c. 5. If last panel finishes more than 5 away from outside of wall, see Finishing Rake details on Page CB-50. EFFECTIVE MAY 15, 2014 SEE FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE CB-49
52 OPEN FRAMING RAKE FINISHING OFF MODULE NOTES FINISHING DIMENSION 15 ³ ₄" - 8" 1. Install Field Curved Rake Support to wood Field Curved Rake Angle with Fastener #5 at 24 on center. 2. Field cut last panel and bend up a 1 leg. Apply Tri-Bead Tape Sealer to 1 leg. 3. Install male leg cut from a curved panel to the 1 leg of the last panel. Attach with Fastener #1E at 12 o.c. Fastener must go through tape sealer. 4. Apply Tri-Bead Tape Sealer to top of male leg and install Curved Rake Trim with Fastener #14A at 12 o.c. FINISHING DIMENSION 7 ³ ₄" - 5 ¹ ₄" 1. Install clips to last panel as normal and apply Tri-Bead Tape Sealer continuous to top of male leg. 2. Install a Low, Fixed Clip at each purlin at the location in which the Curved Rake Trim and Variable Trim will intersect. 3. Cut female leg from curved panel and install on top of plywood spacer strip with Fastener #18 at 24" o.c. 4. Attach Curved Rake Trim to top of cut female leg with Fastener #14 (2 per trim piece). 5. Apply Tri-Bead Tape Sealer to top of Curved Rake Trim, directly in line with the female panel leg. Install Variable Termination Trim with Fastener #4 at 12" o.c. at the attachment to the male leg of the last panel and 6" o.c. at the attachment to the Variable Termination Trim. CB-50 SUBJECT TO CHANGE WITHOUT NOTICE SEE FOR CURRENT INFORMATION EFFECTIVE MAY 15, 2014
53 OPEN FRAMING HIGH EAVE LOW SYSTEM HIGH SYSTEM NOTES LOW SYSTEM 1. Install eave plate to eave strut with Fastener #17 at 1'-0" on center. 2. Install outside closures as shown on page CB-23 with Fastener #14A. 3. Apply Tri-Bead Tape Sealer to top leg of outside closures and install High Eave Trim with Fastener #14A at 6 o.c. HIGH SYSTEM 1. Install eave plate to eave strut with Fastener #17 at 1'-0" on center. 2. Install outside closures as shown on page CB-23 with Fastener # Apply Tri-Bead Tape Sealer to top leg of outside closures and install High Eave Trim with Fastener #14A at 6 o.c. EFFECTIVE MAY 15, 2014 SEE FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE CB-51
54 OPEN FRAMING PARAPET HIGH EAVE LOW SYSTEM HIGH SYSTEM NOTES LOW SYSTEM 1. Install eave plate to eave strut with Fastener #17 at 1'-0" on center. 2. Install outside closures as shown on page CB-23 with Fastener # Apply Tri-Bead Tape Sealer to top leg of outside closures and install Parapet High Eave Trim with Fastener #14A at 6 o.c. HIGH SYSTEM 1. Install eave plate to eave strut with Fastener #17 at 1'-0" on center. 2. Install outside closures as shown on page CB-23 with Fastener # Apply Tri-Bead Tape Sealer to top leg of outside closures and install Parapet High Eave Trim with Fastener #14A at 6 o.c. CB-52 SUBJECT TO CHANGE WITHOUT NOTICE SEE FOR CURRENT INFORMATION EFFECTIVE MAY 15, 2014
55 OPEN FRAMING PARAPET RAKE BEGINNING/FINISHING ON MODULE MASONRY PARAPET WALL PANEL OR EIFS SYSTEM PARAPET NOTES 1. Install clips to last panel as normal and apply Tri-Bead Tape Sealer, continuous, to top of male leg. 2. Install EPDM membrane over male leg and up the side of the parapet wall. Tri-Bead Tape Sealer must be applied to both sides of the EPDM membrane at both the male leg and the parapet wall. 3. Install Curved Parapet Rake Trim to the male leg of the last panel with Fastener #4 at 12 o.c. and to the parapet wall with Fastener #11 at 24 o.c.. EFFECTIVE MAY 15, 2014 SEE FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE CB-53
56 OPEN FRAMING PARAPET RAKE FINISHING OFF MODULE NOTES FINISHING DIMENSION 5 ¹ ₄" - 7 ³ ₄" 1. Install clips to last panel as normal and apply Tri-Bead Tape Sealer continuous to top of male leg. 2. Install ³ ₈" x 6" long plywood spacer strip along rake edge of deck. 3. Cut female leg from curved panel and install on top of plywood spacer strip with Fastener #15C at 24" o.c. 4. Attach Curved Parapet Rake Trim to top of cut female leg with Fastener #14 (2 per trim piece). 5. Apply Tri-Bead Tape Sealer to top of Curved Parapet Rake Trim, directly in line with the female panel leg. Install Variable Termination Trim with Fastener # 4 at 12" o.c. at the attachment to the male leg of the last panel and 6" o.c. at the attachment to the Variable Termination Trim. FINISHING DIMENSION 8" - 17 ³ ₄" 1. Install field curved rake support over Rigid Insulation and Bearing Plate with Fastener #15C at 24 o.c. 2. Field cut last panel and bend up a 1" leg. Apply Tri-Bead Tape Sealer to 1" leg. 3. Install male leg cut from a curved panel to the 1" leg of the last panel. Attach with Fastener #1E at 12" o.c. Fastener must go through tape sealer. 4. Apply Tri-Bead Tape Sealer to top of male leg and install Curved Parapet Rake Trim with Fastener #4 at 12" o.c. CB-54 SUBJECT TO CHANGE WITHOUT NOTICE SEE FOR CURRENT INFORMATION EFFECTIVE MAY 15, 2014
57 SEAMING SEAMING OPERATION As panels are installed, hand seam at each clip with hand crimper. Panels should be completely seamed with electric seamer as soon as possible. Push locking arm down to lock hand crimper onto seam. If difficulty is encountered, check to make sure that hand crimper is properly aligned on seam. Do not force locking arm. Push crimping arm down to crimp panel. Return both the crimping arm and locking arm to the up position and remove tool from seam. EFFECTIVE MAY 15, 2014 SEE FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE CB-55
58 SEAMING SEAMING OPERATION The electric seamer will run upslope and downslope and is controlled by a hand held forward and reverse remote switch. The seamer will form the seam in either direction. When the panels are installed from right to left, forward is up slope, and when the panels are installed left to right, forward is down s l o p e. An orientation plate on the seamer indicates forward and reverse. When the roof has endlaps, the panels will always be installed right to left. The remote switch is designed to stop the seamer when the button is released. On lower sloped roofs walking with the seamer is recommended. On steep sloped roofs (6:12 and greater) a 12- gauge extension cord (not by MBCI) may be installed between the remote switch and the seamer. Seaming can then be accomplished by starting the seamer at the eave from a safety lift. When using this method the seam will be formed upslope and then the seamer will be reversed down the seam to the eave, removed, and placed on the next seam. During panel installation hand crimp the end of the panels 12" down slope from the ridge or high side of the roof. Stop the seamer at this point to prevent the seamer from running into the flashings or running off the roof. Finish remainder of seam with the hand crimper. To begin seaming, set the seamer on the seam with the locking arm up and to the open side of the seam. The wheels should be even with the edge of CAUTION Seamer operation should be closely supervised at all times. A safety line should be attached to the seamer. Be aware of which direction the seamer will move before engaging the switch. Do not entangle the electrical cords in the seamer tooling while it is in operation. This could cause serious injury or death to the operator and severely damage the seamer. Electrical cords should be 10-gauge to provide power to the seamer and never be over 200 feet from the electrical source. The seamer will move approximately 6 to 8 inches after the hand switch is released. Bring seamer to a complete stop before CB-56 SUBJECT TO CHANGE WITHOUT NOTICE SEE FOR CURRENT INFORMATION EFFECTIVE MAY 15, 2014
59 NOTES
60 For current information, visit our Website at Descriptions and specifications contained herein were in effect at the time this publication was approved for printing. In a continuing effort to refine and improve products, MBCI reserves the right to discontinue products at any time or change specifications and/or designs without incurring obligation. To ensure you have the latest information available, please inquire or visit our website at Application details are for illustration purposes only and may not be appropriate for all environmental conditions, building designs or panel profiles. Projects should be designed to conform to applicable building codes, regulations and accepted industry practices. If there is a conflict between this manual and project erection drawings, the erection drawings will take precedence. Houston, TX West Hardy P.O. Box Houston, TX Adel, GA 1601 Rogers Road P.O. Box 1107 Adel, GA Atlanta, GA 2280 Monier Avenue P.O. Box Atlanta, GA Atwater, CA 550 Industry Way P.O. Box 793 Atwater, CA Dallas, TX 1804 Jack McKay Blvd. P.O. Box 1210 Ennis, TX Indianapolis, IN 1780 McCall Drive P.O. Box 657 Shelbyville, IN Jackson, MS 201 Apache Drive P.O. Box Jackson, MS Lubbock, TX 5711 East FM-40 P.O. Box Lubbock, TX Memphis, TN 300 Highway 51 North P.O. Box 366 Hernando, MS Oklahoma City, OK 7000 S. Eastern Avenue P.O. Box Oklahoma City, OK Omaha, NE 1011 Ellison Avenue Omaha, NE Phoenix, AZ 660 South 91st Avenue P.O. Box 739 Tolleson, AZ Richmond, VA 801 South Avenue P.O. Box 239 Colonial Heights, VA Rome, NY 6168 State Route 233 P.O. Box 4141 Rome, NY Salt Lake City, UT 1155 West 2300 North P.O. Box Salt Lake City, UT San Antonio, TX 8677 I-10 East P.O. Box 69 Converse, TX Litho in U.S.A /5M
Technical Installation Information
Technical Installation Information IMPORTANT NOTICE READ THIS MANUAL COMPLETELY PRIOR TO BEGINNING THE INSTALLATION OF THE ULTRA-DEK ROOFING SYSTEM. ALWAYS INSPECT EACH AND EVERY PANEL AND ALL ACCESSORIES
Standing Seam Roof Systems
Standing Seam Roof Systems REAL PEOPLE. REAL PRODUCTS. REAL SOLUTIONS. www.a-s.com Building Benefits You Can Expect From A&S Materials Standing Seam roof panels weigh a relatively modest 11/2 pounds per
SECTION 07410 PREFORMED METAL STANDING SEAM ROOFING PART 1 - GENERAL 1.1 DESCRIPTION OF WORK
SECTION 07410 PREFORMED METAL STANDING SEAM ROOFING PART 1 - GENERAL 1.1 DESCRIPTION OF WORK A. This section covers the pre-finished, pre-fabricated Architectural standing seam roof system. All metal trim,
Technical Installation Information
Technical Installation Information IMPORTANT NOTICE READ THIS MANUAL COMPLETELY PRIOR TO BEGINNING THE INSTALLATION OF THE Double-Lok ROOFING SYSTEM. ALWAYS INSPECT EACH AND EVERY PANEL AND ALL ACCESSORIES
GUIDELINE SPECIFICATIONS
GUIDELINE SPECIFICATIONS GORDON SOFFIT-SHIELD - An Exterior Metal Soffit System DIVISION 05 5800 or DIVISION 07 7700 Note To Specifier: SOFFIT-SHIELD should be installed by tradesmen that are experienced
SECTION 07400 STANDING SEAM METAL ROOF
SECTION 07400 STANDING SEAM METAL ROOF PART 1 - GENERAL 1.01 SECTION INCLUDES A. Work described in this section includes pre-formed standing seam metal roofing system complete with clips, perimeter and
SECTION 07720 PREFORMED METAL STANDING SEAM ROOFING
SECTION 07720 PREFORMED METAL STANDING SEAM ROOFING PART ONE GENERAL DESCRIPTION This section includes pre-formed standing seam metal roofing and related flashings, closures, trim and accessories including,
VERTICAL LOCK Table of Contents
Table of Contents TABLE OF CONTENTS Vertical Lock Product Data Sheet... 2 Vertical Lock Engineering Data... 3 General Information... 6 Material Testing... 7 Panel Overview... 8 Handling Material & Storage
SECTION 07 61 13 STANDING SEAM METAL ROOFING
SECTION 07 61 13 STANDING SEAM METAL ROOFING PART 1 GENERAL 1.01 SCOPE OF WORK A. The Work shall include all labor, materials, equipment and supervision required to complete the work of the above referenced
Table of Contents. Western States Standing Seam SS675 Panel Installation, Flashings & Shop Drawing Detail Guide. Notes to Designer /Installers..
Western States Standing Seam SS675 Panel Installation, Flashings & Shop Drawing Detail Guide Table of Contents Section Page Section Page Notes to Designer /Installers.. 1 Fastener Placement and Selection.2-3
LokSeam. Design/Installation Information. This booklet includes: Trims and Accessories Design and Installation Information
LokSeam Design/Installation Information This booklet includes: Trims and Accessories Design and Installation Information Since 1908 ABC has developed a strong reputation by providing top quality reliable
The Butler MR-24 Standing Seam Roof Difference. A comparison between metal roof systems
The Butler MR-24 Standing Seam Roof Difference A comparison between metal roof systems Roof Systems Necessities Weathertight (don t leak!) Low maintenance Weathertightness Roof clips, seams, panel alignment
Preformed Metal Roofing and Siding
Page -1-1. GENERAL 1.1. Description This specification along with the drawings covers the furnishing of all material, products, equipment, accessories, tools, services, transportation, labor and supervision
Double-Lok. Technical/Installation Information
Double-Lok Technical/Installation Information IMPORTANT NOTICE READ THIS MANUAL COMPLETELY PRIOR TO BEGINNING THE INSTALLATION OF THE DOUBLE-LOK ROOFING SYSTEM. MBCI DETAILS MUST BE FOLLOWED AS A MINIMUM
238T Standing Seam Metal Roof System (SSMRS)
238T Standing Seam Metal Roof System (SSMRS) Text in red are instructions to the specifier and should be deleted. Text in blue are choices that need to be made, with those not selected, deleted. McElroy
Residential Roofing Guide
Residential Roofing Guide TABLE OF CONTENTS Building Detail and Accessories...... 1 Panel Introduction and Handling...... 2 Cutting and Trimming.... 3 Roof Preparation..... 3 Roof Slope..... 3 Re-roofing...
ABSeam Panel Overview and Installation Instructions
82 Garden Spot Road Ephrata, PA 17522 717-445-6885 35 Ridge Road Newville, PA 17241 717-776-5951 ABSeam Panel Overview and Installation Instructions Applications: The ABSeam panel is an architectural panel
HHS J.W. Peavy Center Exterior Walls Waterproofing and Roof Replacement Project WBS # H-000018-0006-4 SECTION 07610 STANDING SEAM METAL ROOFING
PART 1 - GENERAL 1.01 DESCRIPTION SECTION 07610 A. Furnish and install a weather and watertight prefabricated standing seam roof system complete, in place, as shown on the drawings and as specified herein.
CHAPTER 7: Building Systems ROOFING SYSTEMS
ROOFING SYSTEMS Purpose Examples 1. Shingle roof system 2. Metal roof with blanket insulation 3. Metal roof with rigid insulation 4. Built-up asphalt roof system 5. Single-ply roof system 6. Modified Bitumen
PRODUCT SPECIFICATIONS
LokSeam LokSeam 12" One of the most versatile architectural metal panels available today, LokSeam by ABC, is a snap-together, concealed fastener, standing seam roof system with a 13/4" tall vertical rib,
SECTION 07 42 13 METAL WALL PANELS
Mitsubishi Plastics Composites America, Inc. 401 Volvo Parkway Chesapeake, VA 23320 Phone: (800) 422-7270 Fax: (757) 436-1896 E-mail: [email protected] www.alpolic-northamerica.com This MANU-SPEC utilizes
Table of Contents. Western States RustWall Wall and Soffit Panels Installation, Flashings & Shop Drawing Detail Guide
Western States RustWall Wall and Soffit Panels Installation, Flashings & Shop Drawing Detail Guide Table of Contents Section Page Section Page Notes to Designer /Installers.. 1 Fastener Placement and Selection.2-3
AIA PRESENTATION. Standing Seam Metal Roofing Seminar SSRLU2B 1 LU/HSW Hour
AIA PRESENTATION Standing Seam Metal Roofing Seminar SSRLU2B 1 LU/HSW Hour Best Practice MBCI is a Registered Provider with the American Institute of Architects Continuing Education Systems. Credit earned
Drexel Metals Inc. DMC 100SS 16oz min. Copper Mechanical Seam Metal Roof System over Plywood
Drexel Metals Inc. DMC 100SS 16oz min. Copper Mechanical Seam Metal Roof System over Plywood Section 07411 Metal Roof Panels Part 1 General 1.1 Summary A. This section includes the following: a. Factory-formed
Slim Seam Architectural Design Manual
Slim Seam Architectural Design Manual Headquarters: 3449 Hempland Road Lancaster, PA 17601 Phone: 800-477-2741 Fax: 800-283-4289 Architectural Products Division: 308 Alabama Blvd. Jackson, GA 30233 Phone:
Discount Direct Metal Roofing Plus Rib Roofing Panels Installation Instructions
Discount Direct Metal Roofing Plus Rib Roofing Panels Installation Instructions All questions and concerns please call 904-696-9700 Discount Direct Metal Roofing Plus Rib metal roofing panels are a strong,
Specifications. Preformed Metal Wall and Roof Panels. Alcoa Cladding Systems Manufacturing Plant 100 Industrial Boulevard Eastman, Georgia 31023
Specifications Preformed Metal Wall and Roof Panels Alcoa Cladding Systems Manufacturing Plant 100 Industrial Boulevard Eastman, Georgia 31023 Section 07410 Preformed Metal Wall and Roof Panels Structural
Holiday Inn Express & Suites Covington (Newton County) 1. Standing-seam metal roofing, custom fabricated.
PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Standing-seam metal roofing, custom fabricated. 1.2 SUBMITTALS A. Product Data: For each type of product indicated. B. Shop Drawings: Show installation
Nucor VR16 II TM Vertical Rib Standing Seam Roof System
Nucor VR16 II TM Vertical Rib Standing Seam Ro System www.nucorbuildingsystems.com Nucor VR16 II Vertical Rib Standing Seam Ro Perfect for the Marketplace The Nucor Building Systems VR16 II Ro Panel is
SL-16. Concealed Fastener System. This booklet includes: Trims and Accessories Design and Installation Information
SL-16 Concealed Fastener System This booklet includes: Trims and Accessories Design and Installation Information IMPORTANT NOTICE READ THIS MANUAL COMPLETELY PRIOR TO BEGINNING THE INSTALLATION OF ANY
SL 16. Concealed Fastener System. This booklet includes: Trims and Accessories Design and Installation Information
SL 16 Concealed Fastener System This booklet includes: Trims and Accessories Design and Installation Information IMPORTANT NOTICE READ THIS MANUAL COMPLETELY PRIOR TO BEGINNING THE INSTALLATION OF THE
Asphalt Shingle Application Requirements
Alberta Allied Roofing Association Asphalt Shingle Application Requirements Section 1 Roof Decks 1.1 General Asphalt Shingles are not permitted to be installed directly over rigid insulation. When Asphalt
STANDING SEAM SHEET METAL ROOFING
STANDING SEAM SHEET METAL ROOFING GENERAL INFORMATION 1.1 For all standing seam metal roofing work consult Columbia University Facilities Exteriors and Historic Preservation group. 1.2 Fabricator is responsible
DENVER MODEL 30 X 30 SPECIFICATIONS
DENVER MODEL 30 X 30 SPECIFICATIONS Dimensions: Roof Dimensions 30-0 x 30-0 (4) Columns (Center to Center) 25-6½ x 25-6½ Minimum Clearance 8-0 Roof Height @ Peak Dependent on Col. Ht. Hip Roof 4:12 pitch
SECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront
PART 1 GENERAL 1.01 Work Included SECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS System 402 Flush-Glazed Screw Spline Storefront A. Furnish and install aluminum architectural storefront system
SECTION 08332 COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)
SECTION 08332 COILING COUNTER DOORS Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES A. Coiling Metal Counter Doors. B. Coiling Counter Fire Doors. 1.2
SECTION 07410 METAL ROOF & WALL PANELS
This document specifies Metal Roofing Systems prefinished factory formed metal roofing marketed as MRS System 2500 steel and aluminum roofing systems and includes MRS flashing and Trim. MRS finish is a
ATLANTA MODEL SPECIFICATIONS
ATLANTA MODEL 50 SPECIFICATIONS Dimensions: Roof Dimensions (point to point) 50-0 Column Dimensions (out to out of columns) 44-0 Eave Height 8-0 Roof Height @ Peak ±21-8⅞ Hip Roof 6:12 pitch Square Feet
INSTALLATION MANUAL For Grand Rib-3 / Multi Purpose / & Classic Rib Roofing Panels
INSTALLATION MANUAL For Grand Rib-3 / Multi Purpose / & Classic Rib Roofing Panels Grand Rib-3 / Multi-Purpose / Classic Rib Grand Rib-3 / Multi-Purpose / & Classic Rib Grand Rib 3 panels are a strong,
PART 1 GENERAL 1.1 SECTION INCLUDES
J-1 Section 09110 Long Form Specification INTERIOR METAL STUD FRAMING This section includes lightweight, usually 0.036 inch (0.9 mm) thick or lighter, non-axial load bearing metal stud framing including
Installation Manual for STANDING SEAM ROOFING
Installation Manual for STANDING SEAM ROOFING Absolute Steel Toll Free 877-833-3237 / Phone 480-768-1618 / Fax 480-768-1514 www.metalroofingsource.com Standing Seam features approximately one-inch high
MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590
TABLE OF CONTENTS. Roof Decks 172 B, BA, BV Deck N, NA Deck. Form Decks 174.6 FD,.6 FDV Deck 1.0 FD, 1.0 FDV Deck 1.5 FD Deck 2.0 FD Deck 3.
Pages identified with the NMBS Logo as shown above, have been produced by NMBS to assist specifiers and consumers in the application of New Millennium Building Systems Deck products. Pages identified with
COLORADO MODEL. 35 x 65 SPECIFICATIONS
COLORADO MODEL 35 x 65 SPECIFICATIONS Dimensions: Roof Dimensions 35-0 x 65-0 Column Dimensions (center to center) 31-0 x 30-6 Minimum Clearance 14-0 Roof Height @ Peak ±18-8 Curved Roof ±42-6 radius Square
PREMIUM LAMINATED ASPHALT SHINGLES Dallas, TX Tuscaloosa, AL Phillipsburg, KS
Application Instructions for THESE ARE THE MANUFACTURER S APPLICATION INSTRUCTIONS FOR THE ROOFING CONDITIONS DESCRIBED. TAMKO BUILDING PRODUCTS, INC. ASSUMES NO RESPONSIBILITY FOR LEAKS OR OTHER ROOFING
Metal Building Systems Installation and Flashings & Details Guide. Table of Contents
Table of Contents Section Page Notes to Designer/User..................1-2 Map of Typical Roof Conditions............3 Fastener Placement.......................4 Fastener Selection........................5
NEW ELECTRICAL SUBSTATION Building 300 SECTION 07 53 23 ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK
ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK PART 1 GENERAL 1.1 REFERENCES The publications listed below form a part of this specification to the extent referenced. The publications are referred to within
SECTION 07411 STANDING SEAM METAL ROOFING
PART 1 - GENERAL 1.1 SUMMARY A. Section includes the following: 1. Standing-seam metal roof. 2. Metal gutters. 1.2 DEFINITIONS A. Metal Roof Panel Assembly: Metal roof panels, waterproofing membrane (underlayment),
STANDARD PROCEDURES FOR INSTALLATION OF METAL ROOF SYSTEMS
ROOFING APPLICATION STANDARD (RAS) No. 133 STANDARD PROCEDURES FOR INSTALLATION OF METAL ROOF SYSTEMS 1. Scope 1.1 This application standard has been developed to provide consistent information for the
Final inspections are completed by site visit only. Access to fenced yards shall be planned.
ROOFING RESIDENTIAL BUILDING INSPECTIONS DEPARTMENT www.ci.blaine.mn.us This handout is intended only as a guide and is based in part on the 2015 Minnesota State Building Code, Blaine City ordinances,
PANELIZED HOME INSTALLATION GUIDELINE
PANELIZED HOME INSTALLATION GUIDELINE A typical home package will be constructed of Snap-N-Lock Insulated Panels clad with steel skins. 4" panels will be used for the walls, and 6" panels for the roof.
09/07/07 GLASSFIBER REINFORCED CEMENT (GRC) C. S. I. Spec 03500 Master Spec. 03 49 00 Page 1
C. S. I. Spec 03500 Page 1 PART 1 - GENERAL 1.01 SUMMARY:.01 Provide special glassfiber reinforced cement (GRC) shapes in accordance with the requirements of the contract documents..02 The installing contractor
BRIDGE & SUPPLY COMPANY. Installation Guide. Ultra 2000. Includes:
BRIDGE & SUPPLY COMPANY Installation Guide Ultra 2000 Includes: Ultra 2000 Installation Guide Stock Trim Profiles Ultra 2000 Trim Installation Guide Page 2 Table of Contents Ultra 2000 Profile, Colors
CONSTRUCTION DETAILS & LOAD DESIGN CHARTS
Office and Production 126 New Pace Rd., PO Box 279 Newcomerstown, OH 43832 1-800-446-2188, Fax: 740-498-4184 www.buildwithsips.com CONSTRUCTION DETAILS & LOAD DESIGN CHARTS Table of Contents Description
Preventing Ice Dams on Roofs
Preventing Ice Dams on Roofs Facility Manager November/December 2005 When a roof leaks, facility managers inevitably receive complaints from building occupants. If it is winter, ice dams are often the
SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS
SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft Word
Shingle Installation Guide
Shingle Installation Guide Getting Started Dedicated to improving the environment, NewTech manufactures roofing tiles that are composed of up to 90% recycled post-industrial plastic. The manufacture of
TABLE OF CONTENTS" SECTION 3: Comparing Standing Seam Metal to Other Metal Roofs PAGE 7"
2 TABLE OF CONTENTS SECTION 1: What is a Standing Seam Metal Roof PAGE 3 SECTION 2: Common Types of Standing Seam Metal Roofs..PAGE 5 SECTION 3: Comparing Standing Seam Metal to Other Metal Roofs PAGE
INSTALLATION. General. Important Note. Design. Transport
General The roof trusses you are about to install have been manufactured to precise engineering standards. To ensure that the trusses perform as designed, it is essential that they be handled, erected
RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000
RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 SECTION R905 REQUIREMENTS FOR ROOF COVERINGS R905.1 Roof covering application. Roof coverings
SECTION 05 7360 ALUMINUM HANDRAIL AND RAILING SYSTEMS WITH DECORATIVE METAL PANEL INFILLS
1 SECTION 05 7360 ALUMINUM HANDRAIL AND RAILING SYSTEMS WITH DECORATIVE METAL PANEL INFILLS PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and
SECTION 1 GENERAL REQUIREMENTS
Page 1 of 6 SECTION 1 GENERAL REQUIREMENTS 1. SCOPE OF WORK: The work to be performed under the provisions of these documents and the contract based thereon includes furnishing all labor, equipment, materials,
INSTALLATION OF A BAY WINDOW
INSTALLATION OF A BAY WINDOW Installation of a Bay Window These instructions relate to the replacement of an existing bay window or replacement of a straight window with a new bay window, in an opening
DIVISION: 07 00 00 THERMAL AND MOISTURE PROTECTION SECTION: 07 41 13 METAL ROOF PANELS REPORT HOLDER: FIRESTONE BUILDING PRODUCTS COMPANY, LLC
0 ICC ES Report ICC ES (800) 423 687 (62) 699 043 www.icc es.org 000 Most Widely Accepted and Trusted ESR 3422 Reissued 09/201 This report is subject to renewal 09/2016. DIVISION: 07 00 00 THERMAL AND
4572 N Old US 31, Rochester, IN 46975 Toll Free: 877-889-7802 Fax: 574-223-7846 www.ramcosupply.com DETAIL MANUAL. and guide to Ramco Supply products
4572 N Old US 31, Rochester, IN 46975 DETAIL MANUAL and guide to Ramco Supply products Metal Roofing and Siding Panels & Accessories 1 4572 N Old US 31, Rochester, IN 46975 Ramco Supply s RAM Roofing Panels
City of San Diego, CWP Guidelines
PART 1 -- GENERAL SECTION 08520-1.1 WORK OF THIS SECTION City of San Diego, CWP Guidelines A. The WORK of this Section includes providing aluminum windows with frames, bracing, glazing attachments, screens,
A. Double lock standing seam, single element, metal roof panels.
Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions SECTION 07 41 13 METAL ROOF PANELS Morin Metal Panels Double Lock Standing Seam Metal Roof Panels PART 1 - GENERAL 1.1
HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES
HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES 101 Retrofits Required. Pursuant to Section 553.844 553.884, Florida Statutes, strengthening of existing site-built,
CB-100 CB-150 CS-100 SL-100 SL-150 SLZ-1000
CB-100 CB-150 CS-100 SL-100 SL-150 SLZ-1000 Details and Installation Guide October 2013 All information, descriptions and dimensions in this manual are current at the time of printing. As always, Custom-Bilt
Section Page Section Page
Western States Western Rib Panel Installation, Flashings & Shop Drawing Detail Guide Table of Contents Section Page Section Page Notes to Designer / Installers..1 Fastener Placement and Selection.2-3 Key
Larry Haight's Residential Roofing Co, Inc 15203 NE 95th Street Redmond, Washington Phone: (425) 881-9771 Fax: (425) 869-1010
Larry Haight's Residential Roofing Co, Inc 15203 NE 95th Street Redmond, Washington Phone: (425) 881-9771 Fax: (425) 869-1010 Custom bid generated for: Job site address: Lake Villas Condominium Attention:
Sun Windows General Information Sun New Construction Window Installation Instructions
Sun Windows General Information Section 1 G F H H H A. Apply Weather Resistive Barrier B. Apply Sill Flashing Tape C. Place Waterproof Sill Shims D. Caulk Back of Nail Fin Sides & Top, Set Window, Fasten
SECTION 07320 ROOFING TILE
SECTION 07320 ROOFING TILE PART 1 - GENERAL 1.1 SUMMARY: A. Section Includes: 1. Vitrified clay roofing tiles. 2. Tile accessories. 3. Felt underlayment. 4. Self-adhering sheet underlayment. 5. Snow guards.
SECTION 15076 CEMENT-MORTAR LINED AND COATED STEEL PIPE
SECTION 15076 CEMENT-MORTAR LINED AND COATED (CML&C) STEEL PIPE PART 1 GENERAL 1.01 DESCRIPTION This section designates the requirements for steel pipe fabrication, test in shop, installation of steel
ENGINEERING SPECIFICATION PULTRUDED DYNARAIL FIBERGLASS LADDER & LADDER CAGES
ENGINEERING SPECIFICATION PULTRUDED DYNARAIL FIBERGLASS LADDER & LADDER CAGES PART 1 - GENERAL 1.1 SCOPE OF WORK SECTION 06610 FIBERGLASS REINFORCED PLASTICS (FRP) FABRICATIONS PULTRUDED SQUARE TUBE LADDER
Snap-Loc. Installation Guide
Snap-Loc Installation Guide IMPORTANT INFORMATION THE APPLICATION AND DETAIL DRAWINGS IN THIS MANUAL ARE STRICTLY FOR ILLUSTRATION PURPOSES AND MAY NOT BE APPLICABLE TO ALL BUILDING DESIGNS OR PRODUCT
CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN 55110 Fax: 651-429-8503. Re-Roofing: Asphalt Shingles
CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN 55110 Fax: 651-429-8503 Re-Roofing: Asphalt Shingles This is a summary of the standard requirements based on the
ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS
ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS 1. 2. 3. 3.0 Scope 1.1 This application standard shall be used where the authority having jurisdiction has adopted its use, and
A D D E N D U M # 3 QUESTIONS FROM BIDDERS: DATE: November 5, 2012. All Bidders. Jenne dos Santos, CBI Consulting Inc. City of Chelsea, MA
Page 1 of 10, Addendum No. 3 Temporary Garage Structure City of Chelsea, MA November 5, 2012 CBI Job No.: 12055-A A D D E N D U M # 3 DATE: November 5, 2012 TO: FROM: PROJECT: All Bidders Jenne dos Santos,
Air-Conditioning, Heating, and Refrigeration Institute. Sheet Metal and Air-Conditioning Contractors National Association
Air-Conditioning, Heating, and Refrigeration Institute Sheet Metal and Air-Conditioning Contractors National Association GUIDELINE B-1997 ACKNOWLEDGEMENT These guidelines for Roof Mounted Outdoor Air-
Residential Deck Safety, Construction, and Repair
Juneau Permit Center, 4 th Floor Marine View Center, (907)586-0770 This handout is designed to help you build your deck to comply with the 2006 International Residential Building code as modified by the
4 Installation Requirements
4 Installation Requirements 9 4.1 Code Reference The authority having jurisdiction should be referenced to determine what law, ordinance or code shall apply in the use of flexible duct. Ducts conforming
UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Architectural. Roofing. Basis of Design
Basis of Design This section applies to roofing membranes, flashing and accessories. Design Criteria Adhere to the standards and details of the latest editions of the National Contractors Association (NRCA)
Commercial Roof Management
Disclaimer: This material is designed and intended for general informational purposes only, and is not intended, nor shall it be construed or relied upon, as specific legal advice. Roof damage is a leading
Packaged Terminal Air Conditioner Wall Sleeve Installation
Installation & Maintenance Data IM 1196 Group: PTAC Part Number: 910141799 Date: October 2013 Packaged Terminal Air Conditioner Installation x 42" PGAN with Top-Mounted Hydronic Heat Note: Installation
September 3, 2009. Ric Boyd, Public Works Director Ketchikan Gateway Borough 344 Front St. Ketchikan, AK 99901
September 3, 2009 Ric Boyd, Public Works Director Ketchikan Gateway Borough 344 Front St. Ketchikan, AK 99901 RE: Ketchikan Gateway Borough Gateway Recreation Center Roof Observations and Intrusive Inspections
Wastewater Capital Projects Management Standard Construction Specification
CITY AND COUNTY OF DENVER ENGINEERING DIVISION Wastewater Capital Projects Management Standard Construction Specification 10.1 Precast Concrete Pipe 10.1.1 General This section covers material requirements,
metal Duil~ing manufacturers Association
metal Duil~ing manufacturers Association ApplicatiDns metal Building Systems Conventional Buildings Retrofit Roofing Projects l~e Perfect Cover.One of the most important technological advances in building
SECTION 07410 METAL ROOF SYSTEM
SECTION 07410 METAL ROOF SYSTEM PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and General Provisions of Contract, including General Conditions and other Division 1 Specification Sections, apply to
foot skylight) is enough to knock a worker off their feet. A 10 mph wind gust on a 5 x 6 skylight develops a wind force of 270 lbs.
Skylight Installation Instructions This document provides instruction and guidelines for installation of both curb mount (CM) and self flashing (SF) unit skylights on flat, pitched (> or equal to 3/12
KLM 2100. Technical/Erection Information
KLM 2100 Technical/Erection Information IMPORTANT NOTICE READ THIS MANUAL COMPLETELY PRIOR TO BEGINNING THE INSTALLATION OF THE KLS KLM 2100 ROOFING SYSTEM. IF THERE IS A CONFLICT BETWEEN PROJECT ERECTION
1.02 DESCRIPTION A. This Section specifies furnishing and installing Cast in Place Detectable/Tactile Warning Surface tiles where indicated.
CAST IN PLACE DETECTABLE/TACTILE WARNING SURFACE TILE PART 1 GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General and Special Conditions and Division 1 Specifications
CHAPTER VII. TITLE: STANDARDS FOR NEW ROOFING July 2015 CONSTRUCTION, RE-ROOFING CONSTRUCTION AND ROOFING SYSTEM GUARANTEE REQUIREMENTS
TITLE: STANDARDS FOR NEW ROOFING CONSTRUCTION, RE-ROOFING CONSTRUCTION AND ROOFING SYSTEM GUARANTEE REQUIREMENTS Responsible Organization: Office of Facilities Planning Instructions: This Manual supersedes
POST AND FRAME STRUCTURES (Pole Barns)
POST AND FRAME STRUCTURES (Pole Barns) Post and frame structures. The following requirements serve as minimum standards for post and frame structures within all of the following structural limitations:
WESTERN COOL ROOF SYSTEMS Sustainable - Energy Efficient FLUID APPLIED REINFORCED ROOF SYSTEM
WESTERN COOL ROOF SYSTEMS Sustainable - Energy Efficient FLUID APPLIED REINFORCED ROOF SYSTEM SPECIFICATION NO. SMAA-2P-8xE UPGRADE SMOOTH SURFACE / CAP SHEET / SINGLE PLY 2 PLY POLYESTER REINFORCED ACRYLIC
Select Radiators Installation Guide
Select Radiators Installation Guide Table of Contents Informational Symbols...3 Before You Begin...4 Select Rough-In... 5 Connection Installation...6 Optional Piping Arrangements...7 Conventional Wall
Sun Vinyl New Construction Windows Homeowner's Warranty
Sun Windows Sun Vinyl New Construction Windows Homeowner's Warranty Vinyl Sun Windows, Inc. warrants for a period of 2 years that the quality of workmanship and materials of vinyl items shall be free from
March 14, 2007. Installation of Bay, Bow and Garden Windows
March 14, 2007 Re: Installation of Bay, Bow and Garden Windows Attached are the Atrium Companies, Inc recommendation for the installation of bay, bow and garden windows. These instructions were developed
