Gallery, Gallery Plus and Gallery Plus Beermaster

Size: px
Start display at page:

Download "Gallery, Gallery Plus and Gallery Plus Beermaster"

Transcription

1 Gallery, Gallery Plus and Gallery Plus Beermaster Product Information Document Revision: 5.1 Document code: D13052 March 2015

2 Copyright 2015 Thermo Fisher Scientific Inc. and its subsidiaries. All rights reserved. This document is copyright protected and any reproduction of the whole or any part of this document is strictly prohibited, except with the written authorization of Thermo Fisher Scientific. The contents of this document are subject to change without notice. Thermo Fisher Scientific makes no representations that this document is complete, accurate or errorfree. All technical information in this document is for reference purposes only. System configurations and specifications in this document supersede all previous information received by the purchaser. This document is not part of any sales contract between Thermo Fisher Scientific and a purchaser. This document shall in no way govern or modify any Terms and Conditions of Sale, which Terms and Conditions of Sale shall govern all conflicting information between the two documents. Thermo Fisher Scientific Oy Ratastie 2, P.O.Box 100 FI Vantaa FINLAND Tel: [email protected]

3 C Contents Chapter 1 Intended audience... 1 Chapter 2 Chapter 3 Chapter 4 Chapter 5 Purchase order requirements...3 Ordering codes for Gallery analyzers...5 Ordering codes for Gallery Plus analyzers...7 Ordering codes for Gallery Plus Beermaster analyzers...9 Chapter 6 PC accessories - geographical settings Chapter 7 Consumables Chapter 8 Chapter 9 Chapter 10 Chapter 11 Chapter 12 Start-up kits...17 Installation and periodical maintenance kits for trained service engineers Interference filters...25 Filter sets' wavelengths in nm...27 System reagent documents...29 Chapter 13 Advice for returning Chapter 14 Chapter 15 Warranty claim technical sheet...33 Advice for returning electrodes...35 Chapter 16 Installation warranty for electrodes Chapter 17 Chapter 18 Gallery - 5 systems - recommended spare parts...39 Gallery - 10 systems - recommended spare parts...41 Chapter 19 Gallery Plus - 5 systems - recommended spare parts Chapter 20 Gallery Plus - 10 systems - recommended spare parts Chapter 21 Gallery Plus Beermaster - 5 systems - recommended spare parts Chapter 22 Appendix 1 Appendix 2 Gallery Plus Beermaster - 10 systems - recommended spare parts...49 Measurement Wavelengths for Thermo Scientific Gallery System Applications System Reagents for Food and Other Sample Materials...53 Appendix 3 System Reagents for Water Samples Thermo Scientific iii

4 (this page was intentionally left blank)

5 1 Intended audience The intended audience of this document is the commercial organization. Thermo Scientific 1

6 (this page was intentionally left blank)

7 2 Purchase order requirements Purchase order must be in written form and include the following information complete invoicing address complete delivery address (no P.O. Box) VAT number for European Union countries contact person with contact details purchase order number ordering code analyzer PC accessories Start-up kit Installation Qualification Kit consumables reagents quantity complete item description in English price currency terms of payment requested delivery time requested method of transportation terms of delivery (Incoterms 2000) requested special documents / certificates, if any special instructions for shipping, customs etc., if any Please note, that terms of delivery is FCA Helsinki and buyer is responsible for insurance and freight charges. With mutual agreement terms of delivery can be changed and costs will be added to invoice. You will receive our Order Confirmation in 1 2 days after we have received your Purchase Order. Purchase order should be sent by to [email protected] Thermo Scientific 3

8 (this page was intentionally left blank)

9 3 Ordering codes for Gallery analyzers Table 1. Gallery ordering codes Ordering code Item Gallery Gallery with ECM unit Table 2. Analyzer package includes Item PCS Also available separately Analyzer 1 PC unit 1 Binder (contains Image DVD, Manufacturing certificate, Empty USB flash drive for data saving) 1 Spare water container 1 Sample racks 6 SP06666 Reagent racks 3 SP06662 Analyzer power cable 1 Workstation power cable 1 Thermo Scientific 5

10 3 Ordering codes for Gallery analyzers Ordering codes for Gallery analyzers Item PCS Also available separately USB cable 1 PC-accessories as ordered Table 3. Shipping information Item Shipping box Total weight Description 122x82x125 cm 180 kg See detailed dimensions information from Installation manual. Note It is recommended to have UPS for power loss protection in analyzer and workstation. Connect UPS only to the workstation, monitor and analyzer. Do not connect UPS to the printer. Minimum recommendation for UPS is 1500 VA. Table 4. All Gallery models Ordering code Product name Internal use description Gallery Water filters set Gallery Wine filters set Gallery Juice filters set Gallery Enzymes/Food filters set Gallery Beer filters set Gallery ECM unit and Water filters set Gallery ECM unit and Wine filters set Gallery ECM unit and Juice filters set Gallery ECM unit and Enz/Food filters set Gallery ECM unit and Beer filters set 6 Thermo Scientific

11 4 Ordering codes for Gallery Plus analyzers Table 5. Gallery Plus ordering codes Ordering code Item Gallery Plus Gallery Plus with ECM unit Table 6. Analyzer package includes Item PCS Also available separately Analyzer 1 PC unit 1 Binder (contains Image DVD, Manufacturing certificate, Empty USB flash drive for data saving) 1 Spare water container 1 Sample racks 6 SP06666 Reagent disc 42 position 1 Analyzer power cable 1 Workstation power cable 1 Thermo Scientific 7

12 4 Ordering codes for Gallery Plus analyzers Ordering codes for Gallery Plus analyzers Item PCS Also available separately USB cable 1 PC-accessories as ordered Table 7. Shipping information Item Shipping box Total weight Description 122x82x125 cm 200 kg See detailed dimensions information from Installation manual. Note It is recommended to have UPS for power loss protection in analyzer and workstation. Connect UPS only to the workstation, monitor and analyzer. Do not connect UPS to the printer. Minimum recommendation for UPS is 1500 VA. Table 8. All Gallery Plus models Ordering code Product name Internal use description Gallery Plus Water filters set Gallery Plus Wine filters set Gallery Plus Juice filters set Gallery Plus Enz/Food filters set Gallery Plus Beer filters set Gallery Plus ECM unit and Water filters set Gallery Plus ECM unit and Wine filters set Gallery Plus ECM unit and Juice filters set Gallery Plus ECM unit and Enz/Food filters set Gallery Plus ECM unit and Beer filters set 8 Thermo Scientific

13 5 Ordering codes for Gallery Plus Beermaster analyzers Table 9. Gallery Plus Beermaster ordering codes Ordering code Item Gallery Plus Beermaster Gallery Plus Beermaster with the ECM unit Gallery Plus Beermaster with the BCM unit Table 10. Analyzer package includes Item PCS Also available separately Analyzer 1 PC unit 1 Binder (contains Image DVD/memory stick, Manufacturing certificate, Empty USB flash drive for data saving) 1 Spare water container 1 Sample racks 6 SP06666 Thermo Scientific 9

14 5 Ordering codes for Gallery Plus Beermaster analyzers Ordering codes for Gallery Plus Beermaster analyzers Item PCS Also available separately Reagent racks 3 SP06662 BCM column installed Reagent disc 42 positions 1 Bottle closure assembly 1 BC system liquid bottle holder 1 Sample Prep Block Holder - Sample Prep Block 2 SP00563 Analyzer power cable 1 Workstation power cable 1 USB cable 1 PC-accessories as ordered Table 11. Shipping information Item Shipping box Total weight Description 122x82x125 cm 200 kg See detailed dimensions information from Installation manual. Note It is recommended to have UPS for power loss protection in analyzer and workstation. Connect UPS only to the workstation, monitor and analyzer. Do not connect UPS to the printer. Minimum recommendation for UPS is 1500 VA. 10 Thermo Scientific

15 6 PC accessories - geographical settings Code Device Power-cord Keyboard Touch-screen, 2D scanner EUR GE Flat-screen, 2D scanner EUR GE Touch-screen EUR GE Flat-screen EUR GE Touch-screen, 2D scanner EUR FR Flat-screen, 2D scanner EUR FR Touch-screen EUR FR Flat-screen EUR FR Touch-screen, 2D scanner EUR SCE Flat-screen, 2D scanner EUR SCE Touch-screen EUR SCE Flat-screen EUR SCE Touch-screen, 2D scanner EUR US Flat-screen, 2D scanner EUR US Touch-screen EUR US Flat-screen EUR US Touch-screen, 2D scanner UK UK Flat-screen, 2D scanner UK UK Touch-screen UK UK Flat-screen UK UK Thermo Scientific 11

16 6 PC accessories - geographical settings PC accessories - geographical settings Code Device Power-cord Keyboard Touch-screen, 2D scanner US US Flat-screen, 2D scanner US US Touch-screen US US Flat-screen US US Touch-screen, 2D scanner AUS/CN US Flat-screen, 2D scanner AUS/CN US Touch-screen AUS/CN US Flat-screen AUS/CN US Touch-screen, 2D scanner UK US Flat-screen, 2D scanner UK US Touch-screen UK US Flat-screen UK US Touch-screen, 2D scanner EUR RUS Flat-screen, 2D scanner EUR RUS Touch-screen EUR RUS Flat-screen EUR RUS 12 Thermo Scientific

17 7 Consumables Table 12. Consumables for Gallery Ordering code Item In stock* In stock for ECM customers** DECACELL cuvettes 5400 tests ,5 ml sample cups 1000 pcs ml sample cups 1000 pcs ml sample cups 1000 pcs ml tubes 1000 pcs ml reagent bottles 5 pcs ml reagent bottles 16 pcs Washing solution 4.5% 4 x 20 ml Washing solution 4.5% 6 x 100 ml Cleansing solution 100 ml Tubing maintenance solution 6 x 20 ml ECM ph 2 standard 2 x 60 ml ECM ph 4 standard 2 x 60 ml ECM ph 7 standard 2 x 60 ml ECM ph 10 standard 2 x 60 ml ECM ph 12 standard 2 x 60 ml ECM conductivity 0.1 standard 1 pc ECM conductivity 1.4 standard 2 x 60 ml ECM conductivity 13 standard 2 x 60 ml ECM conductivity 112 standard 1 pc Thermo Scientific 13

18 7 Consumables Consumables Ordering code Item In stock* In stock for ECM customers** ECM prime 4 x 20 ml ECM rinse liquid 4 x 400 ml Bag for ECM Reference 5 x 2 ml Reference electrode 1 pc ph electrode 1 pc SP06662 Reagent rack 3 pcs SP06666 Sample rack 6 pcs * Recommended to have in stock. **Recommended to have in stock for customers having ECM unit. Table 13. Consumables for Gallery Plus Beermaster Ordering code Item In stock* Separately ordered D.G.R** DECACELL cuvettes 5400 tests ,5 ml sample cups 1000 pcs ml sample cups 1000 pcs ml sample cups 1000 pcs ml tubes 1000 pcs ml reagent bottles 5 pcs ml reagent bottles 16 pcs Washing solution 4.5% 4 x 20 ml Washing solution 4.5% 6 x 100 ml Tubing maintenance solution 6 x 20 ml BC system liquid 1000 ml BC diluent 4 x 9 ml BC eluent 20 x 15 ml 14 Thermo Scientific

19 7 Consumables Consumables Ordering code Item In stock* Separately ordered D.G.R** BCM column 1 pc Sample prep block 2940 cells SP00563 Holder sample prep block 2 pcs SP06662 Reagent rack 3 pcs SP06666 Sample rack 6 pcs * Recommended to have in stock. **These solutions must be ordered separately and must be transported by air freight following the Dangerous Goods Regulations (D.G.R.) given by IATA. Thermo Scientific 15

20 (this page was intentionally left blank)

21 8 Start-up kits Table 14. Start-up kit (986100) Ordering code Item Start-up kit 1 pc Consists of: Tubing maintenance solution 6 x 20 ml DECACELL cuvettes 5400 tests ml sample cups 1000 pcs Washing solution 4.5% 4 x 20 ml ml reagent bottles 16 pcs Table 15. Complete start-up kit (986101) Ordering code Item Complete start-up kit 1 pc Consists of: Tubing maintenance solution 6 x 20 ml DECACELL cuvettes 5400 tests ml sample cups 1000 pcs ml sample cups 1000 pcs ml tubes 1000 pcs ml reagent bottles 16 pcs ml reagent bottles 5 pcs Thermo Scientific 17

22 8 Start-up kits Start-up kits Ordering code Item Washing solution 4.5% 4 x 20 ml Table 16. ECM start-up kit (986200) Ordering code Item ECM start-up kit 1 pc Consists of: Reference electrode 1 pc ph electrode 1 pc EC Assembly 1 pc SP09701 Spacer slice 9 mm 1 pc Cleansing solution 100 ml Washing solution 4 x 20 ml ECM prime 4 x 20 ml ECM rinse liquid 4 x 400 ml Table 17. Upgrade kits Ordering code Item SP10973 Touchscreen 1 pc SP D scanner 1 pc Note Upgrade kits include all required parts. 18 Thermo Scientific

23 9 Installation and periodical maintenance kits for trained service engineers Table 18. Installation and qualification kit for Gallery with ECM Ordering code Spare part Installation qualification kit - Dispensing Table 19. Periodical maintenance kit for Gallery Plus Beermaster Ordering code SP98009 Spare part Beermaster Complete preventive maintenance kit Consists of: Syringe 500 ul (2 pcs) SP11257 SP07729 SP06817 SP07153 SP08018 Dispensing probe (2 pcs) BCM probe Air filter (3 pcs) Mixing paddle BCM tubing SP12770 Dispensing tubes with BCM, platform type 862 Table 20. Periodical maintenance kit for Gallery with ECM Ordering code SP98001 Spare part Complete PM kit for Gallery with ECM Consists of: Syringe 500 ul SP06189 SP06817 SP07153 ECM dispensing probe Air filters (3 pcs) Mixing paddle Thermo Scientific 19

24 9 Installation and periodical maintenance kits for trained service engineers Installation and periodical maintenance kits for trained service engineers Ordering code SP07184 Spare part Tube set for ECM dispenser SP10054 Dispensing tubes with ECM, platform type 861/863 SP11257 Dispensing probe Table 21. Periodical maintenance kit for Gallery Plus with ECM Ordering code SP98005 Spare part Complete PM kit for Gallery Plus with ECM Consists of: Syringe 500 ul (2 pcs) SP06189 SP06817 SP07153 SP07184 ISE/ECM dispensing probe Air filters (3 pcs) Mixing paddle Tube set for ECM dispenser SP10053 Dispensing tubes with ISE/ECM, platform type 862/864 SP11257 Dispensing probe (2 pcs) Table 22. Periodical maintenance kit for Gallery without ECM Ordering code Spare part SP98002 Complete PM kit without ISE/ECM (type 861/863) Consists of: Syringe 500 ul SP06817 SP07153 Air filters (3 pcs) Mixing paddle SP09592 Dispensing tubes without ISE/ECM, platform type 861/863 SP11257 Dispensing probe Table 23. Periodical maintenance kit for Gallery Plus without ECM Ordering code SP98006 Spare part PLUS Complete preventive maintenance kit without ISE/ECM/BCM 20 Thermo Scientific

25 9 Installation and periodical maintenance kits for trained service engineers Installation and periodical maintenance kits for trained service engineers Ordering code Spare part Consists of: Syringe 500 ul (2 pcs) SP06817 SP07153 Air filters (3 pcs) Mixing paddle SP09591 Dispensing tubes without ISE/ECM/BCM, platform type 862/864 SP11257 Dispensing probe Table 24. Periodical maintenance kit for Gallery water with ECM Ordering code SP98003 Spare part Complete preventive maintenance kit water with ECM Consists of: Syringe 500 ul SP07466 SP07467 White Assembly B White Assembly A EC Assembly SP06189 SP06817 SP07153 SP07184 ISE/ECM dispensing probe Air filters (3 pcs) Mixing paddle Tube set for ECM dispenser SP10054 Dispensing tubes with ISE/ECM, platform type 861/863 SP11253 Dispensing probe (water) Table 25. Periodical maintenance kit for Gallery Plus water with ECM Ordering code SP98007 Spare part Complete preventive maintenance kit water with ECM Consists of: Syringe 500 ul (2 pcs) SP07466 White Assembly B Thermo Scientific 21

26 9 Installation and periodical maintenance kits for trained service engineers Installation and periodical maintenance kits for trained service engineers Ordering code SP07467 Spare part White Assembly A EC Assembly SP06189 SP06817 SP07153 SP07184 ISE/ECM dispensing probe Air filters (3 pcs) Mixing paddle Tube set for ECM dispenser SP10053 Dispensing tubes with ISE/ECM, platform type 862/864 SP11253 Dispensing probe (water) (2 pcs) Table 26. Periodical maintenance kit for Gallery water without ECM Ordering code SP98004 Spare part Complete preventive maintenance kit water without ECM Consists of: Syringe 500 ul SP06817 SP07153 Air filters (3 pcs) Mixing paddle SP09592 Dispensing tubes without ISE/ECM, platform type 861/863 SP11253 Dispensing probe (water) Table 27. Periodical maintenance kit for Gallery Plus water without ECM Ordering code SP98008 Spare part Complete preventive maintenance kit water without ECM Consists of: Syringe 500 ul (2 pcs) SP06817 SP07153 Air filters (3 pcs) Mixing paddle SP09591 Dispensing tubes without ISE/ECM, platform type 862/ Thermo Scientific

27 9 Installation and periodical maintenance kits for trained service engineers Installation and periodical maintenance kits for trained service engineers Ordering code SP11253 Spare part Dispensing probe (water) (2 pcs) Thermo Scientific 23

28 (this page was intentionally left blank)

29 10 Interference filters Code SP10830 SP10841 SP10842 SP16604 SP10843 SP15440 SP10844 SP10860 SP10845 SP13341 SP10846 SP10847 SP03581 SP10848 SP10849 SP10850 SP10861 SP10851 SP10852 SP10853 SP14256 SP10854 Wavelengths 275 nm 340 nm 380 nm 400 nm 405 nm 410 nm 420 nm 430nm 450 nm 460 nm 480 nm 492 nm 500 nm 510 nm 520 nm 540 nm 550 nm 575 nm 600 nm 620 nm 645nm 660 nm Thermo Scientific 25

30 10 Interference filters Interference filters Code SP14257 SP10855 SP10856 SP16331 SP12845 Wavelengths 665nm 700 nm 750 nm 810 nm 880 nm 26 Thermo Scientific

31 11 Filter sets' wavelengths in nm Common wavelengths Water (-1) Wine (-2) Juice (-3) Enzymes/Food (-4) Beer (-5) Beermaster (-6) New filter sets are in constant development. If you have special needs or any kind of questions concerning filters, please send an to Thermo Scientific 27

32 (this page was intentionally left blank)

33 12 System reagent documents Our documents can be downloaded from the website at Safety Data sheets Inserts Certificates of Analysis Thermo Scientific 29

34 (this page was intentionally left blank)

35 13 Advice for returning For returning goods to the factory, you need to contact first the Customer Service. Inform the reason for returning and you will receive the authorization number (RMA-number) and additional shipping instructions. Items should be returned to the factory within 3 (three) months from the date RMA-number has been issued. In case of warranty/ other type of reclamation, the WARRANTY CLAIM TECHNICAL SHEET must be filled. See the following page. RETURN To be used in case you want to return goods to the factory (error in ordering or delivery). Shipment should be sent with a Proforma invoice and mention the RMA-number as a reference. Please contact immediately after arrival of the goods and follow the shipping instructions Received goods must be in new-like condition After receipt of the goods you will be credited. We do not accept perishable goods to be returned, such as reagents, calibrators, standards, controls and other solutions. WARRANTY To be used when you want to return parts under warranty. Warranty periods analyzer - one (1) year from the date of installation, but no more than fourteen (14) months from the shipment spare parts - three (3) months warranty from the installation but no more than six (6) months warranty from the shipment. Failure to make a notification within fourteen (14) days after discovery of any non-conforming shipment or defect shall be deemed a waiver. electrodes - See Installation warranty for electrodes on page 37 Parts returned on warranty bases, should indicate: The WARRANTY CLAIM TECHNICAL SHEET properly filled in. Return the items in their original condition (i.e. neither stripped, nor fixed) Use RMA number as a reference in all documentation Follow the shipping instructions. Only properly returned material attached with completed warranty documentation will be considered. Once the validity of warranty has been verified, we will credit you for full price In case the parts are rejected, we will send them back to you upon your request. Thermo Fisher Scientific Oy will store the parts 1 (one) month after customer has been informed of the rejection Thermo Scientific 31

36 13 Advice for returning Advice for returning Note Replacements have to be ordered separately and they will be sent at full price. OTHER RECLAMATIONS - Please contact Customer Service at [email protected]. 32 Thermo Scientific

37 14 Warranty claim technical sheet RMA number: Customer name: Address: Instrument type: Software version: Serial number: Instrument installation date: Repair date : Part installation date: Item: Code: Problem description: Repairing description: Company/Country: Name: Date: Return parts to: Thermo Fisher Scientific Oy Myllynkivenkuja 8, VANTAA Finland Thermo Scientific 33

38 (this page was intentionally left blank)

39 15 Advice for returning electrodes Electrodes with the documents can be sent directly to our attention. There is no need for a RMA (Return Material Authorization) number for the return of electrodes. All of the correctly returned electrodes will be tested and a decision for the claim will be done within two (2) months after arrival. The warranty claim is valid, only if the pre-requisites below are met: 1. The electrode has been handled and installed according to the manufacturer's instructions (refer to instrument specific Reference or Operation Manual). 2. The last possible installation date from the package label (install before) has been followed. Electrodes have to be stored at 2 8 C before installation. 3. The Installation warranty for electrodes form is properly filled. 4. All items listed below are returned with the electrode filled installation warranty form the electrode in case of the reference electrode, place a paperclip to the reference electrode solution bag to ensure liquid flow to the chamber calibration printouts of first calibration the most recent calibration or printout of the problem 5. All necessary items have to be returned latest after two months the electrode has been replaced or before that if the guarantee period expires. Please return the electrodes with the documents to: Thermo Fisher Scientific Analyzer Support, 3 D Ratastie 2 FI Vantaa Finland For more information, please feel free to contact us at [email protected] Thermo Scientific 35

40 (this page was intentionally left blank)

41 Thermo Fisher Scientific Oy Ratastie 2 tel (0) Page 1 of 2 Clinical Diagnostics, Analyzers & Automation P.O.Box Vantaa, Finland IN THE EVENT OF UNSATISFACTORY FUNCTIONING OF THE ELECTRODE, FOR VALID WARRANTY IT IS PROVIDED THAT: 1. The electrode has been handled and installed according to the manufacturer's instructions (analyzer s specific Installation or Operation Manual). 2. The last possible installation date from the package label (install before) has been followed. Electrodes have to be stored at 2 8 C before installation. 3. This form is properly filled. 4. All items listed below are returned to the importer of the electrode - this form - the electrode, - In case of reference electrode, place paperclip to reference electrode solution bag to ensure liquid flow to chamber. - calibration printouts of first calibration - the most recent calibration or printout of the problem. 5. All necessary items have to be returned within the guarantee period given for each specific product (see Table 1). TABLE 1: GUARANTEE PERIODS FOR ELECTRODES Electrodes for Gallery Code (check the appropriate product) Type/name of electrode Guarantee period (after installation) ECM ph Electrode 6 months ECM Reference Electrode 2 months CUSTOMER DETAILS Customer: Address: Install before date: Installation date: Date of defect: Serial number of the electrode: (printed on packages and bottom of electrode, 6-8 digits) Describe the type of defect: Action(s) taken trying to remove the problems Analyzer type Analyzer serial number Extra washings (using Washing /Cleansing Solution) Gallery Extra prime with ECM Prime Software version Calibrated several times Document D09716_04

42 Page 2 of 2 Reference electrode Other electrodes Yes No Crystals seen in chamber Yes No Air bubbles seen in electrode Yes No Electrode is filled properly Yes No All necessary O-rings between Yes No Air in the tubing or chamber electrodes are in place Yes No Reference filling solution bag is properly in place Yes No All electrode cables are Yes No Outer surface of the reference electrode is clean and dry properly in place Prime solution and QC Controls What kind of prime sample and QC controls are in use Prime sample ECM Prime (984340) QC controls commercial control, please specify Matrix type other, please specify Prime / Control in use (name / manufacturer) Calibration please enclose calibration printouts from before and after the problem Problems in control or sample measurements for ph measurement level too low level too high unstable measurement variation too high Other, please specify Measurements Please enclose problem description print Samples Please specify the matrix How many samples run per day (average) Document D09716_04

43 17 Gallery - 5 systems - recommended spare parts Spare part Description Quantity PM part Water* ECM** SP12312 Background barcode sticker 1pcs SP09158 Bolt Thermistor 1pcs SP09473 Bolt Thermistor 2 1pcs SP10111 Bolt Thermistor 3 1pcs SP98001 Complete PM kit for Gallery with ECM 1pcs SP98002 Complete PM kit for Gallery without ECM 1pcs SP98003 Complete PM kit for Water Gallery with ECM 1pcs SP98004 Complete PM kit for Water Gallery without ECM 1pcs SP09853 Component board CANUSB4 1pcs SP07033 Component board CONTROL4 1pcs SP08684 Component board ISEAMP4 1pcs SP06862 Component board MEAS4 1pcs SP06861 Component board MOTOR4 1pcs SP08334 Component board SURF4 1pcs SP08579 Cooling unit 1pcs SP10193 Cover Sensor 1pcs SP11257 Dispensing Probe 1pcs SP11253 Dispensing Probe (Water) 1pcs SP06189 Dispensing Probe ECM 1pcs SP10054 Dispensing tubes with ECM 1pcs SP09592 Dispensing tubes without ECM 1pcs SP08997 FMI pump 1pcs Thermo Scientific 39

44 17 Gallery - 5 systems - recommended spare parts Gallery - 5 systems - recommended spare parts Spare part Description Quantity PM part Water* ECM** IQ-kit dispensing 1pcs SP07153 Mixing paddle 1pcs SP09052 Opto Switch Assembly 1pcs SP09053 Opto Switch Assembly 2 1pcs SP09196 Opto Switch Assembly 3 1pcs SP10075 Opto Switch Assembly 4 1pcs SP06685 Pressure sensor unit 1pcs Syringe 500 μl 1pcs SP07184 Tube set for ECM Dispenser 1pcs SP04287 Tubing connectors ( 100 pcs) 1pcs * Recommended to have in stock for customers with water Gallerys. ** Recommended to have in stock for customers with ECM unit. 40 Thermo Scientific

45 18 Gallery - 10 systems - recommended spare parts Spare part Description Quantity PM part SP12312 Background barcode sticker 1pcs SP09158 Bolt Thermistor 1pcs SP09473 Bolt Thermistor 2 1pcs SP10111 Bolt Thermistor 3 1pcs Water* ECM** SP98001 Complete PM kit for Gallery with ECM 1pcs SP98002 Complete PM kit for Gallery without ECM 1pcs SP98003 Complete PM kit for Water Gallery with ECM 1pcs SP98004 Complete PM kit for Water Gallery without ECM 1pcs SP09853 Component board CANUSB4 1pcs SP07033 Component board CONTROL4 1pcs SP08684 Component board ISEAMP4 1pcs SP06862 Component board MEAS4 1pcs SP06861 Component board MOTOR4 2pcs SP08334 Component board SURF4 1pcs SP08579 Cooling unit 1pcs SP10193 Cover Sensor 1pcs SP11257 Dispensing Probe 2pcs SP11253 Dispensing Probe (Water) 2pcs SP06189 Dispensing Probe ECM 1pcs SP10054 Dispensing tubes with ECM 1pcs SP09592 Dispensing tubes without ECM 1pcs SP08997 FMI pump 1pcs Thermo Scientific 41

46 18 Gallery - 10 systems - recommended spare parts Gallery - 10 systems - recommended spare parts Spare part Description Quantity PM part SP06743 Hatch Lock 1pcs IQ-kit dispensing 2pcs SP07153 Mixing paddle 1pcs SP09052 Opto Switch Assembly 1pcs SP09053 Opto Switch Assembly 2 1pcs SP09196 Opto Switch Assembly 3 1pcs SP10075 Opto Switch Assembly 4 1pcs SP06242 Photometric head assembly 1pcs SP06685 Pressure sensor unit 1pcs SP06662 Reagent Racks, 3 pcs (incl. label sheets) 1pcs SP06666 Sample Racks, 6 pcs (incl. label sheets) 1pcs Syringe 500 μl 2pcs Water* ECM** SP07184 Tube set for ECM Dispenser 1pcs SP04287 Tubing connectors ( 100 pcs) 1pcs SP09004 Water / waste sensor (cable not included) 1pcs SP06814 Water container assembly 5L 1pcs * Recommended to have in stock for customers with water Gallerys. ** Recommended to have in stock for customers with ECM unit. 42 Thermo Scientific

47 19 Gallery Plus - 5 systems - recommended spare parts Spare part Description Quantity PM part SP12312 Background barcode sticker 1pcs SP09158 Bolt Thermistor 1pcs SP09473 Bolt Thermistor 2 1pcs SP10111 Bolt Thermistor 3 1pcs Water* ECM** SP98005 Complete PM kit for Gallery PLUS with ECM 1pcs SP98006 Complete PM kit for Gallery PLUS without ECM 1pcs SP98007 Complete PM kit for Water Gallery PLUS with ECM 1pcs SP98008 Complete PM kit for Water Gallery PLUS without ECM 1pcs SP09853 Component board CANUSB4 1pcs SP07033 Component board CONTROL4 1pcs SP08684 Component board ISEAMP4 1pcs SP06862 Component board MEAS4 1pcs SP06861 Component board MOTOR4 1pcs SP08334 Component board SURF4 1pcs SP08579 Cooling unit 1pcs SP10193 Cover sensor 1pcs SP11257 Dispensing probe 2pcs SP11253 Dispensing Probe (Water) 2pcs SP06189 Dispensing probe ECM 1pcs SP12770 Dispensing tubes with BCM 1pcs SP10053 Dispensing tubes with ECM (PLUS) 1pcs SP09591 Dispensing tubes without ECM (PLUS) 1pcs Thermo Scientific 43

48 19 Gallery Plus - 5 systems - recommended spare parts Gallery Plus - 5 systems - recommended spare parts Spare part Description Quantity PM part SP08997 FMI pump 1pcs IQ-kit dispensing 1pcs SP07153 Mixing paddle 1pcs SP09052 Opto Switch Assembly 1pcs SP09053 Opto Switch Assembly 2 1pcs SP09196 Opto Switch Assembly 3 1pcs SP10075 Opto Switch Assembly 4 1pcs SP06685 Pressure sensor unit 1pcs Syringe 500 μl 2pcs Water* ECM** SP07184 Tube set for ECM Dispenser 1pcs SP04287 Tubing connectors ( 100 pcs) 1pcs * Recommended to have in stock for customers with water Gallerys. ** Recommended to have in stock for customers with ECM unit. 44 Thermo Scientific

49 20 Gallery Plus - 10 systems - recommended spare parts Spare part Description Quantity PM part SP12312 Background barcode sticker 1pcs SP09158 Bolt Thermistor 1pcs SP09473 Bolt Thermistor 2 1pcs SP10111 Bolt Thermistor 3 1pcs Water* ECM** SP98005 Complete PM kit for Gallery PLUS with ECM 1pcs SP98006 Complete PM kit for Gallery PLUS without ECM 1pcs SP98007 Complete PM kit for Water Gallery PLUS with ECM 1pcs SP98008 Complete PM kit for Water Gallery PLUS without ECM 1pcs SP09853 Component board CANUSB4 1pcs SP07033 Component board CONTROL4 1pcs SP08684 Component board ISEAMP4 1pcs SP06862 Component board MEAS4 1pcs SP06861 Component board MOTOR4 2pcs SP08334 Component board SURF4 1pcs SP08579 Cooling unit 1pcs SP10193 Cover Sensor 1pcs SP00580 Diluent container assembly 7,7L, Plus 1pcs SP11257 Dispensing probe 3pcs SP11253 Dispensing Probe (Water) 3pcs SP06189 Dispensing probe ECM 1pcs Thermo Scientific 45

50 20 Gallery Plus - 10 systems - recommended spare parts Gallery Plus - 10 systems - recommended spare parts Spare part Description Quantity PM part Water* ECM** SP10053 Dispensing tubes with ECM (PLUS) 1pcs SP09591 Dispensing tubes without ECM (PLUS) 1pcs SP08997 FMI pump 1pcs SP06743 Hatch Lock 1pcs IQ-kit dispensing 2pcs SP07153 Mixing paddle 1pcs SP09052 Opto Switch Assembly 1pcs SP09053 Opto Switch Assembly 2 1pcs SP09196 Opto Switch Assembly 3 1pcs SP10075 Opto Switch Assembly 4 1pcs SP06242 Photometric head assembly 1pcs SP06685 Pressure sensor unit 1pcs SP06662 Reagent Racks, 3 pcs (incl. label sheets) 1pcs SP06666 Sample Racks, 6 pcs (incl. label sheets) 1pcs Syringe 500 μl 3pcs SP07184 Tube set for ECM Dispenser 1pcs SP04287 Tubing connectors ( 100 pcs) 1pcs SP09004 Water / waste sensor (cable not included) 1pcs * Recommended to have in stock for customers with water Gallerys. ** Recommended to have in stock for customers with ECM unit. 46 Thermo Scientific

51 21 Gallery Plus Beermaster - 5 systems - recommended spare parts Spare part Description Quantity PM part SP12312 Background barcode sticker 1pcs SP08018 BCM tubing 1pcs SP09158 Bolt Thermistor 1pcs SP09473 Bolt Thermistor 2 1pcs SP10111 Bolt Thermistor 3 1pcs SP98009 Complete PM kit for Beermaster 1pcs SP09853 Component board CANUSB4 1pcs SP07033 Component board CONTROL4 1pcs SP06862 Component board MEAS4 1pcs SP06861 Component board MOTOR4 1pcs SP08334 Component board SURF4 1pcs SP08579 Cooling unit 1pcs SP10193 Cover sensor 1pcs SP11257 Dispensing probe 2pcs SP07729 Dispensing probe BCM 1pcs SP12770 Dispensing tubes with BCM 1pcs SP08997 FMI pump 1pcs IQ-kit dispensing 1pcs SP07153 Mixing paddle 1pcs SP09052 Opto Switch Assembly 1pcs SP09053 Opto Switch Assembly 2 1pcs Thermo Scientific 47

52 21 Gallery Plus Beermaster - 5 systems - recommended spare parts Gallery Plus Beermaster - 5 systems - recommended spare parts Spare part Description Quantity PM part SP09196 Opto Switch Assembly 3 1pcs SP10075 Opto Switch Assembly 4 1pcs SP06685 Pressure sensor unit 1pcs Syringe 500 μl 2pcs SP04287 Tubing connectors ( 100 pcs) 1pcs 48 Thermo Scientific

53 22 Gallery Plus Beermaster - 10 systems - recommended spare parts Spare part Description Quantity PM part SP12312 Background barcode sticker 1pcs SP08018 BCM Tubing 1pcs SP09158 Bolt Thermistor 1pcs SP09473 Bolt Thermistor 2 1pcs SP10111 Bolt Thermistor 3 1pcs SP07805 Bottle cap BC system 1pcs SP98009 Complete PM kit for Beermaster 1pcs SP09853 Component board CANUSB4 1pcs SP07033 Component board CONTROL4 1pcs SP06862 Component board MEAS4 1pcs SP06861 Component board MOTOR4 2pcs SP08334 Component board SURF4 1pcs SP08579 Cooling unit 1pcs SP10193 Cover Sensor 1pcs SP00580 Diluent container assembly 7,7L, Plus 1pcs SP11257 Dispensing probe 3pcs SP07729 Dispensing probe BCM 1pcs SP12770 Dispensing tubes with BCM 1pcs SP08997 FMI pump 1pcs SP06743 Hatch Lock 1pcs IQ-kit dispensing 2pcs Thermo Scientific 49

54 22 Gallery Plus Beermaster - 10 systems - recommended spare parts Gallery Plus Beermaster - 10 systems - recommended spare parts Spare part Description Quantity PM part SP07153 Mixing paddle 1pcs SP09052 Opto Switch Assembly 1pcs SP09053 Opto Switch Assembly 2 1pcs SP09196 Opto Switch Assembly 3 1pcs SP10075 Opto Switch Assembly 4 1pcs SP06242 Photometric head assembly 1pcs SP06685 Pressure sensor unit 1pcs SP06662 Reagent Racks, 3 pcs (incl. label sheets) 1pcs SP06666 Sample Racks, 6 pcs (incl. label sheets) 1pcs Syringe 500 μl 3pcs SP04287 Tubing connectors ( 100 pcs) 1pcs SP09004 Water / waste sensor (cable not included) 1pcs 50 Thermo Scientific

55 Measurement Wavelengths for Thermo Scientific Gallery System Applications Water filter Wine filter Juice filter ENZ/FOOD filter Beer filter Code Reagent λ 1 /λ 2 (main / side wavelength in nm) λ 1 /λ 2 (main / side wavelength in nm) λ 1 /λ 2 (main / side wavelength in nm) λ 1 /λ 2 (main / side wavelength in nm) λ 1 /λ 2 (main / side wavelength in nm) Acetaldehyde / / / / Acetic acid / / / / Acetic Acid (ACS) - 340/ / Alkalinity R1 Alkalinity R2 600 / Alpha-Amino Nitrogen (NOPA) / / (700) 1) 340 / / Alpha-Amylase / Ammonia Kit / / / / Ammonia R1 Ammonia R2 660 / L-Ascorbic acid / / BC Diluent BC Eluent BC System liquid Bitterness 2) / Beta-Glucan (High MW) / / Calcium (Ca) 660 / / / / / Chloride R1 480 / Chromium (VI) 540 / Citric acid / / / / Cholesterol Food / / / Copper - 600/ Color / / Ethanol (low) / / / / D-Fructose / / / / Fluoride R1 Fluoride R2 Fluoride R3 600 / D-Gluconic acid / / / D-Glucose / / / / D-Glucose + D-Fructose / / / / D-Glucose + D-Fructose + Sucrose / / / / Glycerol / / / / -

56 Total Hardness R1 Total Hardness R2 Total Hardness R3 620 / ß-Hydroxybutyrate / / / Total Iron (Fe) / / / / D-Isocitric acid / / / D-Lactic acid / / / / L-Lactic acid / / / / Lactose (Glucose) / / / Magnesium (Mg) 540 / / (405) 1) 520 / (405) 1) 520 / / L-Malic acid / 750 (700 / -) 1) 340 / / Oxalic acid / / / / ph (Colorimetric) 3) 3) 3) 3) 3) Potassium / / Phosphate R1 Phosphate R2 880 / Total acids (Wine ph 7) / / Total acids (Juice ph 8) / (700) 1) 620 / Total Polyphenol / - (700 / -) 1) 700 / / Total Protein (Biuret) / / (700) 1) 540 / / Silica R1 Silica R2 Silica R3 700 / SO2 Free / / (700) 1) 575 / SO2 Total Low / 700 High - (405) 1 / 750 (405 / 700) / Sucrose (Total Glucose) / / / / Sulphate R1 420 / TON R3 540 / TON R1 TON R2 TON R3 540 / TON Enz 540 / TON-V R1 TON-V R2 540 / Urea (Ammonia) / / / / - 1) 2) 3) Filter to be ordered separately Bitterness determination is possible with Gallery Plus Beermaster only ph can be measured by ph electrode/ecm unit thermoscientific.com/gallery thermoscientific.com/galleryplus thermoscientific.com/beermaster 2015 Thermo Fisher Scientific Inc. All rights reserved. All trademarks are the property of Thermo Fisher Scientific Inc. and its subsidiaries. The information and technical specifications are subject to change without notice. CDD Finland Ratastie 2, FI Vantaa Tel: [email protected] 02 / 2015

57 Thermo Scientific Gallery and Arena System Reagents for Food and Other Sample Materials Code Reagent Max no. of tests from the kit Method Acetaldehyde 250 tests Enzymatic test with aldehyde dehydrogenase tests Enzymatic test with acetate kinase Acetic acid ( tests ( Acetic acid (ACS) 150 tests Photometric test with acetyl-coenzyme A synthetase (ACS) Alpha-Amino Nitrogen (NOPA) 300 tests Colorimetric test with OPA (o-phthaldialdehyde) and NAC (N-acetylcysteine) Alpha-Amylase 780 tests Enzymatic test with ethylidene-pnp-g7 (E-pNP-G7) as the substrate (1 Ammonia 300 tests 1000 tests (1 Enzymatic test with glutamate dehydrogenase L-Ascorbic acid 250 tests Colorimetric test with the tetrazolium salt MTT ( ( (2 BC Diluent BC Eluent BC System liquid 360 tests Calcium (Ca) 350 tests Arsenazo lll Column extraction of bittering components from beer and wort and subsequent photometric determination Citric acid 250 tests Enzymatic test with citrate lyase Cholesterol Food 300 tests Enzymatic test with cholesterol oxidase, peroxidase and with colorimetric indicator chinonimin Copper 300 tests Colorimetric test with DiBr-PAESA Ethanol 300 tests Enzymatic test with alcohol-dehydrogenase D-Fructose 300 tests Enzymatic test with hexokinase, phosphoglucose isomerase and glucose-6-phosphate dehydrogenase Beta-Glucan (High MW) 350 tests Novel method D-Gluconic acid 250 tests Enzymatic test with 6-P-gluconate-dehydrogenase and gluconate kinase tests Enzymatic test with hexokinase and glucose-6-phosphate D-Glucose ( tests (1 dehydrogenase ( ( (1 D-Glucose + D-Fructose D-Glucose + D-Fructose + Sucrose Glycerol 300 tests 1000 tests (1 300 tests 1000 tests (1 300 tests 1000 tests ( ß- Hydroxybutyrate 300 tests Total Iron (Fe) 850 tests Ferene S Enzymatic test with hexokinase, phosphoglucose isomerase and glucose-6-phosphate dehydrogenase Enzymatic test with beta-fructosidase (Invertase), hexokinase, phosphoglucose isomerase and glucose-6- phosphate dehydrogenase Enzymatic test with glycerokinase, ADP dependent hexokinase and glucose-6-phosphate-dehydrogenase Enzymatic test with D-3-hydroxybutyric-dehydrogenase and nitrotetrazolium blue

58 D-Isocitric acid 300 tests Enzymatic test with Isocitrate-dehydrogenase D-Lactic acid 300 tests Enzymatic test with D-Lactate-dehydrogenase L-Lactic acid 300 tests Enzymatic test with L-Lactate-dehydrogenase (1 Lactose (3 (Glucose) 300 tests 1000 tests ( Magnesium (Mg) 350 tests Xylidyl Blue I (1 L-Malic acid 300 tests 1000 tests (1 Enzymatic test with galactosidase (Lactase), hexokinase and glucose-6-phosphate dehydrogenase Enzymatic test with L-Malate-dehydrogenase and glutamate-oxalacetate-transaminase Oxalic acid 250 tests Enzymatic test with oxalate oxidase ph (colorimetric) 330 tests Colorimetric test with ph indicator dyes Potassium 300 tests Turbidimetric test with tetraphenylborate Total acids (Wine ph 7) 400 tests Colorimetric test with bromothymol blue Total acids (Juice ph 8) 400 tests Colorimetric test with bromothymol blue Total Polyphenol 280 tests Folin-Ciocalteau method by chromogenic complex Total Protein (Biuret) 450 tests Biuret SO2 Free 430 tests Free sulfite reacts with pararosaniline (PAR) and formaldehyde to give a chromogen under acidic conditions SO2 Total 300 tests Total sulfite reacts with 5, 5 -dithiobis-(2-nitrobenzoic acid) (DTNB) to give a stable chromogen in alkaline conditions Sucrose (3 (Total Glucose) 300 tests Enzymatic test with beta-fructosidase (Invertase), hexokinase and glucose-6-phosphate dehydrogenase Tartaric acid 480 tests Colorimetric test with ammonium monovanadate Urea (4 (Ammonia) 300 tests Enzymatic test with urease and glutamate dehydrogenase (1 Arena Kits only (2 Gallery Plus Beermaster with the Bitterness (BCM) unit only (3 D-Glucose result is needed for Sucrose and Lactose calculation from assayed Glucose (4 Ammonia result is needed for Urea calculation from assayed Ammonia

59 Code Standard For test Kit configuration Acetaldehyde standard Acetaldehyde 3 x 5 ml, 100 mg/l (lot dependent) Acid combination standard Acetic acid, L-Malic acid, L- Lactic acid and D-Lactic acid Alcohol standard Ethanol 10 ampoules, 0.5 g/l 3 x 3 ml, Acetic acid g/l, L-Malic acid g/l, L-Lactic acid 220 mg/l, D-Lactic acid 220 mg/l (lot dependent) Cholesterol Food Std Cholesterol 3 x 3 ml, 2000 mg/l (lot dependent) Copper Std Copper 3 x 5 ml, 5 mg/l (lot dependent) Beta-Glucan standard Beta-Glucan (High MW) 1 x 50 mg, 500 mg/l (lot dependent) Glycerol standard Glycerol 3 x 3 ml, 0.21 g/l (lot dependent) ß- Hydroxybutyrate Std ß- Hydroxybutyrate 3 x 3 ml, 100 mg/l (lot dependent) Lactose standard Lactose (Glucose) 3 x 3 ml, 0.95 g/l (lot dependent) NOPA standard Alpha-Amino Nitrogen 3 x 3 ml, 150 mg/l (lot dependent) Oxalic acid standard Oxalic acid 3 x 3 ml, 45 mg/l (lot dependent) ph 4 standard ph (colorimetric) 2 x 60 ml, (temperature dependent) ph 7 standard ph (colorimetric) 2 x 60 ml, (temperature dependent) Sugar combination standardd D-Glucose, D-Fructose and Sucrose (Total Glucose) 3 x 3 ml, D-Glucose g/l, D-Fructose g/l, Sucrose g/l, Total Glucose g/l (lot dependent) Urea standard Urea (Ammonia) 3 x 3 ml, 500 mg/l (lot dependent) thermoscientific.com/discreteanalysis 2015 Thermo Fisher Scientific Inc. All rights reserved. All trademarks are the property of Thermo Fisher Scientific and its subsidiaries. The information and technical specifications are subject to change without notice. Africa Australia Austria Belgium Brazil Canada China (free call domestic) Denmark Europe-Other Finland France Germany India Italy Japan Korea Latin America Middle East Netherlands New Zealand Norway Russia/CIS Singapore Sweden Switzerland Taiwan UK/Ireland USA / 2015

60 Thermo Scientific Gallery and Aquakem System Reagents for Water Samples Product code ( Product name Analyte Kit size Alkalinity R1 Alkalinity R2 Ammonia R1 Ammonia R2 Alkalinity Ammonia 4 x 20 ml 4 x 20 ml 125 ml 4 x 20 ml Number of tests/ kit ( Calcium (Ca) Calcium 3 x 20 ml Chloride R1 Chloride R1L Chromium (VI) Fluoride R1 Fluoride R2 Fluoride R3 Iron (Ferrous) R1 Iron (Ferrous) R2 Chloride Hexavalent Chromium Fluoride Iron (Ferrous) 4 x 20 ml 20 x 20 ml x 20 ml x 20 ml 4 x 20 ml 4 x 20 ml 4 x 20 ml 4 x 20 ml Magnesium (Mg) Magnesium 8 x 10 ml TON R3 TON R3L TON R1 TON R2 TON R2XL TON R3 TON R3L TON Enz TON-V R1 TON-V R2 Nitrite Nitrate (TON Hyd) Nitrate (TON Enz) Nitrate (TON Vanadium) 4 x 20 ml 20 x 20 ml 125 ml 4 x 20 ml 6 x 60 ml 4 x 20 ml 20 x 20 ml ml x 10 ml 4 x 10 ml Reference (3 ISBN ISO 7150 DIN ISO MDL (4 mg/l 3.4 (a 5.5 (b (a (b Tietz Fundamentals of Clinical Chemistry 4th Ed (a - ISBN SM 4500Cl- E EPA EN ISO ISO SM 3500-Cr B SW 7196-A DIN EN ISO 23913:2009 ISO (a (b Test ranges up to mg/l Low range ( (6 100 (5 High range 10.0 (5 375 ( (a (5 200 (6 500 ( (6 SM 4500-F E EPA (a ISO SM 3500-Fe B 50 (a 40 (b Tietz Fundamentals of Clinical Chemistry 4th Ed. 1.5 (a - ISBN SM 4500NO2 B EPA ISO 13395:1996 DIN EN ISO ISBN SM 4500 NO3 H ISO ASTM D EPA ATP: Nitrogen, Nitrate-Nitrite Method 353.X (EPA approval in process) SM, proposed title: Enzymatic reduction method new method for method 4500-NO3-Nitrogen (Nitrate) Similar to NEMI (8 : Nitrate via manual Vanadium (III) reduction (a (b (a (b ( (a 5.0 (6 500 (5 100 (6 2.5 (5 1.5 (6 25 (5 50 ( (a ( (6

61 Phosphate R1 Phosphate R1L Phosphate R2 Silica R1 Silica R2 Silica R3 Sulphate R1 Sulphate R1XL Total Hardness R1 Total Hardness R2 Total Hardness R3 Phosphate Silica Sulphate Urea (Ammonia) Urea (7 Total Hardness 4 x 20 ml 20 x 20 ml 4 x 20 ml 4 x 20 ml 4 x 20 ml 4 x 20 ml 4 x 20 ml 6 x 60 ml 4 x 20 ml 4 x 20 ml 4 x 20 ml 3 x 16 ml R1 3 x 4.5 ml R2 3 x 4.5 ml R ISBN SM 4500 P E EPA EN ISO 6878 ISO USGS I EPA SM 4500-SiO2 D ISO ISBN SM 4500 SO4 2- E EPA DIN D 5-2 ISO EPA (a (b 0.01 (a 0.05 (b 1.0 ( (a 100 ( (a 10 (b Enzymatic urease method NOTE: 1. Reagents marked with XL in 60 ml vial sizes, TON R2XL and Sulphate R1XL, are only available for Aquakem systems. 2. Number of tests/ kit is test flow dependent number. 3. ISBN number refers to the UK blue book method SM refers to Standard Methods for The Examination of Water and Waste Water, the 21th edition (APHA, AWWA, WEF) SW refers to Standard Methods for Water and Waste Water Methods are adapted for discrete analyzers from referred standards. 4. MDL, Method detection limit, is the minimum concentration of an analyte that can be identified, measured and reported with 99% confidence that the analyte concentration is greater than zero. Measurements were performed by Gallery. a) MDL = 3.14 x SD (blank sample, n = 7) b) MDL = 3 x SD + average (blank sample, 3 batches, n = 30) 5. Application of the Gallery system 6. Application of the Aquakem system 7. Ammonia result is needed for Urea calculation from assayed Ammonia 8. See NIST traceable standard solutions Product code Analyte Volume Product code Analyte Volume Ammonium (as N) Std 500 ml Nitrate (as NO3) Std 500 ml Ammonium (as NH4) Std 500 ml Nitrate (as N) Std 500 ml Chloride Std 500 ml Phosphate (as PO4) Std 500 ml Fluoride Std 100 ml Phosphate (as P) Std 500 ml Nitrite (as NO2) Std 500 ml Sulphate Std 500 ml Nitrite (as N) Std 500 ml

62 NIST traceable standards for ph measurements ECM ph 2 Standard 2 x 60 ml ECM ph 4 Standard 2 x 60 ml ECM ph 7 Standard 2 x 60 ml ECM ph 10 Standard 2 x 60 ml ECM ph 12 Standard 2 x 60 ml NIST traceable standards for Conductivity measurements (ms/cm) ECM Conductivity 0.08 Standard 2 x 60 ml ECM Conductivity 1.4 Standard 2 x 60 ml ECM Conductivity 13 Standard 2 x 60 ml ECM Conductivity 112 Standard 2 x 60 ml thermoscientific.com/discreteanalysis 2015 Thermo Fisher Scientific Inc. All rights reserved. All trademarks are the property of Thermo Fisher Scientific Inc. and its subsidiaries. The information and technical specifications are subject to change without notice. Africa Australia Austria Belgium Brazil Canada China (free call domestic) Denmark Europe-Other Finland France Germany India Italy Japan Korea Latin America Middle East Netherlands New Zealand Norway Russia/CIS Singapore Sweden Switzerland Taiwan UK/Ireland USA / 2015

Cedex Bio HT Bioprocess Analyzer. Be Confident. Be Assured.

Cedex Bio HT Bioprocess Analyzer. Be Confident. Be Assured. Cedex Bio HT Bioprocess Analyzer Be Confident. Be Assured. Next Generation Technology for Bioprocess Analytics Analyze Your Samples with Confidence. Be Assured of the Data Integrity. Metabolite Screening

More information

Thermo Scientific ClinQuan MD Software For In Vitro Diagnostic Use. Confidence in Results With Data Integrity

Thermo Scientific ClinQuan MD Software For In Vitro Diagnostic Use. Confidence in Results With Data Integrity Thermo Scientific ClinQuan MD Software For In Vitro Diagnostic Use Confidence in Results With Data Integrity 2 Make the World Healthier With the LC-MS Tests You Run Confidence in Test Results With Data

More information

Lead Testing and On Site Calibration for Water Testing Detection Range: 2 100ppb

Lead Testing and On Site Calibration for Water Testing Detection Range: 2 100ppb Document: AND Lead 100 7 2013 Lead Testing and On Site Calibration for Water Testing Detection Range: 2 100ppb July, 2013 Edition 1 ANDalyze, Inc., 2012. All rights reserved. Printed in USA. Table of Contents

More information

A fully quantitative research method for the analysis of lead in whole blood using the Thermo Scientific icap Q ICP-MS

A fully quantitative research method for the analysis of lead in whole blood using the Thermo Scientific icap Q ICP-MS A fully quantitative research method for the analysis of lead in whole blood using the Thermo Scientific icap Q ICP-MS Kent W. Warnken, Thermo Fisher Scientific, USA Patrick Messina, Quest Diagnostics,

More information

Agilent 4338B Milliohm Meter

Agilent 4338B Milliohm Meter Agilent 4338B Milliohm Meter 10 µω to 100 kω Technical Overview Introduction Ideal for precise measurements of extremely low resistances using an ac test signal, the Agilent Technologies 4338B suits bench-top

More information

ab176915 StayBlue/AP Plus Stain Kit Instructions for Use An immunohistochemical chromogen substrate for staining tissue sections

ab176915 StayBlue/AP Plus Stain Kit Instructions for Use An immunohistochemical chromogen substrate for staining tissue sections ab176915 StayBlue/AP Plus Stain Kit Instructions for Use An immunohistochemical chromogen substrate for staining tissue sections This product is for research use only and is not intended for diagnostic

More information

Dimethylglyoxime Method Method 10220 0.1 to 6.0 mg/l Ni TNTplus 856

Dimethylglyoxime Method Method 10220 0.1 to 6.0 mg/l Ni TNTplus 856 Nickel DOC316.53.01065 Dimethylglyoxime Method Method 10220 0.1 to 6.0 mg/l Ni TNTplus 856 Scope and application: For water and wastewater. Test preparation Instrument-specific information Table 1 shows

More information

Determination of Pesticide Residues in Drinking Water Using Automated Solid-Phase Extraction and Gas Chromatography with Nitrogen Phosphorus Detection

Determination of Pesticide Residues in Drinking Water Using Automated Solid-Phase Extraction and Gas Chromatography with Nitrogen Phosphorus Detection Determination of Pesticide Residues in Drinking Water Using Automated Solid-Phase Extraction and Gas Chromatography with Nitrogen Phosphorus Detection Application Note 1097 Liu Qian, Zheng Hongguo and

More information

What is Eluent Generation?

What is Eluent Generation? What is Eluent Generation? Monika Verma Thermo Fisher Scientific, Sunnyvale, CA, USA White Paper 70607 Executive Summary Eluent generation is an electrolytic process that allows the production of high

More information

for patient monitoring

for patient monitoring Thermo Scientific Indiko Reagents for Immunosuppressant Drug Testing Complete solutions for patient monitoring The cost-effective Thermo Scientific Indiko benchtop analyzer and bar-coded reagent is designed

More information

Creatine Kinase (CK) Enzymatic Assay Kit Manual Catalog #: 3460-07

Creatine Kinase (CK) Enzymatic Assay Kit Manual Catalog #: 3460-07 Creatine Kinase (CK) Enzymatic Assay Kit Manual Catalog #: 3460-07 TABLE OF CONTENTS GENERAL INFORMATION... 2 Product Description... 2 Procedure Overview... 2 Kit Contents, Storage and Shelf Life... 3

More information

YSI 2900 Series Biochemistry Analyzers FERMENTATION CONTROL FOOD & BEVERAGE CLINICAL RESEARCH

YSI 2900 Series Biochemistry Analyzers FERMENTATION CONTROL FOOD & BEVERAGE CLINICAL RESEARCH YSI 2900 Series Biochemistry Analyzers FERMENTATION CONTROL FOOD & BEVERAGE CLINICAL RESEARCH Fast and Accurate: The YSI Gold Standard YSI has earned a reputation as the Gold Standard in bio-analytical

More information

Agilent 4339B/4349B High Resistance Meters

Agilent 4339B/4349B High Resistance Meters Agilent 4339B/4349B High Resistance Meters Technical Overview Within Budget Without Compromise Introducing the Agilent Technologies 4339B and 4349B High Resistance Meters Used for Making Ultra- High Resistance

More information

Measurement by Ion Selective Electrodes

Measurement by Ion Selective Electrodes Measurement by Ion Selective Electrodes Adrian Vazquez May 8, 2012 Why Use Ion Selective Electrodes? Responsive over a wide concentration range Not affected by color or turbidity of sample Rugged and durable

More information

Standard methods in water analysis

Standard methods in water analysis Branch General analytical laboratories; water analysis Keywords Water analysis; standard methods; ASTM; DIN; ISO; USP; EPA; SLMB; EN; SCA; titration; ion chromatography; voltammetry; branch 1; branch 2

More information

Application of Automated Data Collection to Surface-Enhanced Raman Scattering (SERS)

Application of Automated Data Collection to Surface-Enhanced Raman Scattering (SERS) Application Note: 52020 Application of Automated Data Collection to Surface-Enhanced Raman Scattering (SERS) Timothy O. Deschaines, Ph.D., Thermo Fisher Scientific, Madison, WI, USA Key Words Array Automation

More information

Cadmium Reduction Method Method 8039 0.3 to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls

Cadmium Reduction Method Method 8039 0.3 to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls Nitrate DOC316.53.01066 Cadmium Reduction Method Method 8039 0.3 to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls Scope and application: For water, wastewater and seawater. Test preparation Instrument-specific

More information

Phosphorus, Reactive (Orthophosphate)

Phosphorus, Reactive (Orthophosphate) Phosphorus, Reactive (Orthophosphate) DOC316.53.01113 Amino Acid Method 1 Method 8178 0.23 to 30.00 mg/l PO 4 Reagent Solution Scope and application: For water, wastewater and seawater. 1 Adapted from

More information

Thermo Scientific LIFECYCLE Asset & Service Management for Healthcare

Thermo Scientific LIFECYCLE Asset & Service Management for Healthcare Thermo Scientific LIFECYCLE Asset & Service Management for Healthcare HEALTHCARE SUPPLYSIDE SOLUTIONS Focused on your unique needs for managing assets, costs, and suppliers Part of Thermo Fisher Scientific

More information

Determining the Quantity of Iron in a Vitamin Tablet. Evaluation copy

Determining the Quantity of Iron in a Vitamin Tablet. Evaluation copy Determining the Quantity of Iron in a Vitamin Tablet Computer 34 As biochemical research becomes more sophisticated, we are learning more about the role of metallic elements in the human body. For example,

More information

SOLUTIONS FOR ENVIRONMENTAL ANALYSIS

SOLUTIONS FOR ENVIRONMENTAL ANALYSIS SOLUTIONS FOR ENVIRONMENTAL ANALYSIS 02 MEETING THE CHALLENGES OF SUSTAINABLE DEVELOPMENT The analytical expertise AMS Alliance is one of the major players for analysis in the agro-food and environmental

More information

Installation Qualification/Operational Qualification Protocols and Instructions. Experion Automated Electrophoresis Station and Software

Installation Qualification/Operational Qualification Protocols and Instructions. Experion Automated Electrophoresis Station and Software Installation Qualification/Operational Qualification Protocols and Instructions Experion Automated Electrophoresis Station and Software Validation Kit (Catalog #700-7051) Security Edition Software (Catalog

More information

Thermo Scientific Prelude SPLC System FPO. Making LC/MS accessible. to clinical research and toxicology labs

Thermo Scientific Prelude SPLC System FPO. Making LC/MS accessible. to clinical research and toxicology labs Thermo Scientific Prelude SPLC System FPO Making LC/MS accessible to clinical research and toxicology labs Specifically designed to make the power of LC/MS accessible Analysis of target compounds in complex

More information

Quaternary Ammonium Compounds DOC316.53.01128

Quaternary Ammonium Compounds DOC316.53.01128 Quaternary Ammonium Compounds DOC316.53.01128 Direct Binary Complex Method Method 8337 0.2 to 5.0 mg/l as CTAB (cetyl-trimethylammonium bromide) Powder Pillows Scope and application: For cooling tower

More information

Release Notes: PowerChute plus for Windows 95 and Windows 98

Release Notes: PowerChute plus for Windows 95 and Windows 98 : PowerChute plus for Windows 95 and Windows 98 These release notes supplement the User s Guide: PowerChute plus, Version 5.0.2, for Windows 95 and Windows 98 (pc98ug.pdf) and the Installation Guide: PowerChute

More information

Thermo Scientific Capitol Vial Drugs of Abuse Products. The tools to create and maintain. a safe and drug free environment

Thermo Scientific Capitol Vial Drugs of Abuse Products. The tools to create and maintain. a safe and drug free environment Thermo Scientific Capitol Vial Drugs of Abuse Products The tools to create and maintain a safe and drug free environment Drugs of Abuse Specimen Collection We are a world leading manufacturer of Drugs

More information

Thermo Scientific Compound Discoverer Software. A New Generation. of integrated solutions for small molecule structure ID

Thermo Scientific Compound Discoverer Software. A New Generation. of integrated solutions for small molecule structure ID Thermo Scientific Compound Discoverer Software A New Generation of integrated solutions for small molecule structure ID Transforming Small Molecule Research Solutions for Small Molecule Structural ID Thermo

More information

LAB PROCEDURE Alpha-Amino Nitrogen by NOPA

LAB PROCEDURE Alpha-Amino Nitrogen by NOPA LAB PROCEDURE Alpha-Amino Nitrogen by NOPA From: Method by Dr. Christian Butzke, U.C. Davis. The reagents have been changed slightly for better shelf life. In the original method, NaOH, boric acid, NAC,

More information

Thermo Scientific icap 7000 Series ICP-OES. Low cost ICP-OES analysis high quality data

Thermo Scientific icap 7000 Series ICP-OES. Low cost ICP-OES analysis high quality data Low cost ICP-OES analysis high quality data The NEW Thermo Scientific icap 7000 Series ICP-OES provides low cost multi-element analysis for measuring trace elements in a diverse sample range. The instrument

More information

Milwaukee USER MANUAL

Milwaukee USER MANUAL Milwaukee USER MANUAL PORTABLE DISSOLVED OXYGEN METER MODEL: MW600 Smart DO Meter PROBE PREPARATION: The meter is supplied with a 9V battery. Slide off the battery compartment cover on the back of the

More information

Smart. Scalable. Simple.

Smart. Scalable. Simple. Thermo Scientific Wireless Monitoring Solution Smart. Scalable. Simple. providing the protection you need with the simplicity you deserve Thermo Scientific Wireless Monitoring Solution Optimized Sample

More information

ab185915 Protein Sumoylation Assay Ultra Kit

ab185915 Protein Sumoylation Assay Ultra Kit ab185915 Protein Sumoylation Assay Ultra Kit Instructions for Use For the measuring in vivo protein sumoylation in various samples This product is for research use only and is not intended for diagnostic

More information

EXPERIMENT 5. Molecular Absorption Spectroscopy: Determination of Iron With 1,10-Phenanthroline

EXPERIMENT 5. Molecular Absorption Spectroscopy: Determination of Iron With 1,10-Phenanthroline EXPERIMENT 5 Molecular Absorption Spectroscopy: Determination of Iron With 1,10-Phenanthroline UNKNOWN Submit a clean, labeled 100-mL volumetric flask to the instructor so that your unknown iron solution

More information

A Complete Solution for Method Linearity in HPLC and UHPLC

A Complete Solution for Method Linearity in HPLC and UHPLC Now sold under the Thermo Scientific brand A Complete Solution for Method Linearity in HPLC and UHPLC Frank Steiner, Fraser McLeod, Tobias Fehrenbach, and Andreas Brunner Dionex Corporation, Germering,

More information

Creatine Kinase Activity Assay Kit (Colorimetric)

Creatine Kinase Activity Assay Kit (Colorimetric) ab155901 Creatine Kinase Activity Assay Kit (Colorimetric) Instructions for Use For the sensitive and accurate measurement of Creatine Kinase activity in various samples. This product is for research use

More information

Determination of Calcium and Magnesium in Brine

Determination of Calcium and Magnesium in Brine Application Note Determination of Calcium and Magnesium in Brine INTRODUCTION To prevent membrane poisoning, new membrane technology in chlor-alkali cells requires feed brine that is relatively free of

More information

USEPA 1 FerroVer Method 2 Method 8008 0.02 to 3.00 mg/l Fe Powder Pillows or AccuVac Ampuls

USEPA 1 FerroVer Method 2 Method 8008 0.02 to 3.00 mg/l Fe Powder Pillows or AccuVac Ampuls Iron, Total DOC316.53.01053 USEPA 1 FerroVer Method 2 Method 8008 0.02 to 3.00 mg/l Fe Powder Pillows or AccuVac Ampuls Scope and application: For water, wastewater and seawater; digestion is required

More information

Third Party Instrument Control with Chromeleon Chromatography Data System (CDS) Software

Third Party Instrument Control with Chromeleon Chromatography Data System (CDS) Software Third Party Instrument Control with Chromeleon Chromatography Data System (CDS) Software White Paper 70885 Executive Summary Over the last few decades chromatographic instrumentation and separations have

More information

Chlorine, Total. DPD Method 1 Method 10101 0.09 to 5.00 mg/l Cl 2 Test 'N Tube Vials. Test preparation. Instrument-specific information

Chlorine, Total. DPD Method 1 Method 10101 0.09 to 5.00 mg/l Cl 2 Test 'N Tube Vials. Test preparation. Instrument-specific information Chlorine, Total DOC316.53.01028 DPD Method 1 Method 10101 0.09 to 5.00 mg/l Cl 2 Test 'N Tube Vials Scope and application: For testing higher levels of total (free plus combined) chlorine in drinking water,

More information

Agilent U2000 Series USB Power Sensors

Agilent U2000 Series USB Power Sensors Agilent U2000 Series USB Power Sensors Configuration Guide U2000 Series USB Power Sensors U2000A (10 MHz to 18 GHz) U2001A (10 MHz to 6 GHz) U2002A (50 MHz to 24 GHz) U2004A (9 khz to 6 GHz) U2000H (10

More information

Standard Operating Procedure for Total Kjeldahl Nitrogen (Lachat Method)

Standard Operating Procedure for Total Kjeldahl Nitrogen (Lachat Method) Standard Operating Procedure for Total Kjeldahl Nitrogen (Lachat Method) Grace Analytical Lab 536 South Clark Street 10th Floor Chicago, IL 60605 April 15, 1994 Revision 2 Standard Operating Procedure

More information

Unleash Your Potential

Unleash Your Potential Unleash Your Potential Efficiency. Power. Flexibility. Small In Size Big In Performance. The respons 910 vet A Leap Forward For Your Laboratory. System solution consisting of the respons 910 vet analyzer,

More information

Supplies 1. Toner cartridges. Printing. Using color. Paper handling. Maintenance. Troubleshooting. Administration. Index

Supplies 1. Toner cartridges. Printing. Using color. Paper handling. Maintenance. Troubleshooting. Administration. Index Toner cartridges Supplies 1 Warning: Do not touch the cartridge roller located under the cover. Cover Your printer uses four separate toner cartridges, one for each color: cyan, yellow, magenta, and black.

More information

5.0 EXPERIMENT ON DETERMINATION OF TOTAL HARDNESS

5.0 EXPERIMENT ON DETERMINATION OF TOTAL HARDNESS 5.0 EXPERIMENT ON DETERMINATION OF TOTAL HARDNESS Sl. No. Contents Preamble 5.1 Aim 5.2 Introduction 5.2.1 Environmental Significance 5.3 Principle 5.4 Materials Required 5.4.1 Apparatus Required 5.4.2

More information

HumaStar 100 HumaStar 200

HumaStar 100 HumaStar 200 HumaStar 100 HumaStar 200 Marketing material Key advantages Competition Product features Rev. 4 22.05.2014 How to use this presentation? How to use this presentation? This presentation has not only been

More information

Agilent P940xA/C Solid State PIN Diode Switches

Agilent P940xA/C Solid State PIN Diode Switches Agilent P940xA/C Solid State PIN Diode Switches Operating and Service Manual Agilent Technologies Notices Agilent Technologies, Inc. 2007 No part of this manual may be reproduced in any form or by any

More information

INNOVATION TO MEET YOUR NEEDS

INNOVATION TO MEET YOUR NEEDS INNOVATION TO MEET YOUR NEEDS 100% High Throughput The throughput is optimized splitting the pipetting phases of Reagents and Samples into different cycles. The innovative technical solutions adopted by

More information

PCI Express 1.0 (2.5 GT/s) Protocol Test

PCI Express 1.0 (2.5 GT/s) Protocol Test PCI Express 1.0 (2.5 GT/s) Protocol Test Configuration and Pricing Guide Gen1 today, ready for Gen2 in the future As PCI Express Gen2 becomes more mature in the market, you must decide whether to continue

More information

IC Food Packs. Complete packs for food analysis. Free with every IC Food Pack: MagIC Net software Ultrafiltration

IC Food Packs. Complete packs for food analysis. Free with every IC Food Pack: MagIC Net software Ultrafiltration IC Food Packs Complete packs for food analysis Free with every IC Food Pack: MagIC Net software Ultrafiltration 02 Make your food analysis more efficient! Ion chromatography (IC) is a versatile, proven

More information

Quantum View Manage Administration Guide

Quantum View Manage Administration Guide 2010 United Parcel Service of America, Inc. UPS, the UPS brandmark and the color brown are trademarks of United Parcel Service of America, Inc. All rights reserved. Quantum View Manage Administration Guide

More information

Agilent 87421A/87422A Power Supply

Agilent 87421A/87422A Power Supply Agilent 87421A/87422A Power Supply Technical Overview Designed specifically for Agilent Technologies microwave system amplifiers Bias cable permits remote placement Compact size for easy system integration

More information

Thermo Scientific SOLAµ SPE Plates Technical Guide. Consistent excellence. for bioanalysis

Thermo Scientific SOLAµ SPE Plates Technical Guide. Consistent excellence. for bioanalysis Thermo Scientific SOLAµ SPE Plates Technical Guide Consistent excellence for bioanalysis SOLAµ - delivering reproducible low volume extractions. Everytime! Thermo Scientific SOLAµ plates are designed for

More information

Bio-Rad Laboratories. QC data management solutions. Introduce Your Laboratory to a Whole New World of Unity Data Management Solutions

Bio-Rad Laboratories. QC data management solutions. Introduce Your Laboratory to a Whole New World of Unity Data Management Solutions Bio-Rad Laboratories QC data management solutions QC Data Management Solutions Introduce Your Laboratory to a Whole New World of Unity Data Management Solutions Bio-Rad Laboratories QC data management

More information

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research J. Jones, J. Denbigh, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 20581 Key Words SPE, SOLA,

More information

ab102884 FITC Conjugation Kit Protocol

ab102884 FITC Conjugation Kit Protocol ab102884 FITC Conjugation Kit Protocol Antibody and protein modification This product is for research use only and is not intended for diagnostic use. Version 1 Last Updated 4 November 2013 Table of Contents

More information

Canine creatine kinase MB isoenzyme (CK-MB)ELISA Kit

Canine creatine kinase MB isoenzyme (CK-MB)ELISA Kit Canine creatine kinase MB isoenzyme (CK-MB)ELISA Kit Catalog No. CSB-E15852c (96T) This immunoassay kit allows for the in vitro quantitative determination of canine CK-MB concentrations in serum and plasma.

More information

LIFECYCLE. Thermo Scientific. Enterprise Solutions

LIFECYCLE. Thermo Scientific. Enterprise Solutions Thermo Scientific LIFECYCLE Enterprise Solutions Support Plans Improve productivity and quality Increase production uptime Extend instrument lifetime Lower overall cost-of-ownership Keep instruments up-to-date

More information

Thermo Scientific Nunc Products for InVitro Fertilization. security, safety and reproducibility. for your valuable. samples

Thermo Scientific Nunc Products for InVitro Fertilization. security, safety and reproducibility. for your valuable. samples Thermo Scientific Nunc Products for InVitro Fertilization security, safety and reproducibility for your valuable samples The criteria for an IVF product is that it is reliable and does not offer any threat

More information

Keysight M9485A PXIe Multiport Vector Network Analyzer. Configuration Guide

Keysight M9485A PXIe Multiport Vector Network Analyzer. Configuration Guide Keysight M9485A PXIe Multiport Vector Network Analyzer Configuration Guide 02 Keysight M9485A PXIe Multiport Vector Network Analyzer - Configuration Guide Ordering Guide The following steps will guide

More information

Simoa HD-1 Analyzer Troubleshooting Guide. USER-104-28 17 Sep 2014 Software Version 1.3 Beta

Simoa HD-1 Analyzer Troubleshooting Guide. USER-104-28 17 Sep 2014 Software Version 1.3 Beta Simoa HD-1 Analyzer Troubleshooting Guide USER-104-28 17 Sep 2014 Software Version 1.3 Beta Customer Support Customer support is available 8 AM to 8 PM, EDT. Phone: 1-877-786-8749 Email: [email protected]

More information

Rat Creatine Kinase MB isoenzyme,ck-mb ELISA Kit

Rat Creatine Kinase MB isoenzyme,ck-mb ELISA Kit Rat Creatine Kinase MB isoenzyme,ck-mb ELISA Kit Catalog No: E0479r 96 Tests Operating instructions www.eiaab.com FOR RESEARCH USE ONLY; NOT FOR THERAPEUTIC OR DIAGNOSTIC APPLICATIONS! PLEASE READ THROUGH

More information

FerroVer Method 1 Method 10249 0.1 to 3.0, 1.0 to 30.0 and 10.0 to 300.0 mg/l Fe Powder Pillows

FerroVer Method 1 Method 10249 0.1 to 3.0, 1.0 to 30.0 and 10.0 to 300.0 mg/l Fe Powder Pillows Iron, Total DOC316.53.01314 FerroVer Method 1 Method 10249 0.1 to 3.0, 1.0 to 30.0 and 10.0 to 300.0 mg/l Fe Powder Pillows Scope and application: For oil and gas field waters; digestion is required for

More information

Phosphorus, colorimetry, phosphomolybdate, automated-segmented flow

Phosphorus, colorimetry, phosphomolybdate, automated-segmented flow Phosphorus, colorimetry, phosphomolybdate, automated-segmented flow Parameter and code: Phosphorus, total-in-bottom-material, dry weight, I-6600-88 (mg/kg as P): 00668 1. Application This method is used

More information

SCH 4C1 Unit 2 Problem Set Questions taken from Frank Mustoe et all, "Chemistry 11", McGraw-Hill Ryerson, 2001

SCH 4C1 Unit 2 Problem Set Questions taken from Frank Mustoe et all, Chemistry 11, McGraw-Hill Ryerson, 2001 SCH 4C1 Unit 2 Problem Set Questions taken from Frank Mustoe et all, "Chemistry 11", McGraw-Hill Ryerson, 2001 1. A small pin contains 0.0178 mol of iron. How many atoms of iron are in the pin? 2. A sample

More information

PCI Express Probes for Agilent E2960B PCI Express Analysis Systems

PCI Express Probes for Agilent E2960B PCI Express Analysis Systems PCI Express for Agilent E2960B PCI Express Analysis Systems Version: 1.2 Superior Signal Probing options to address diverse designs and form factors As an industry leader in the innovation of non-intrusive,

More information

ArC Amine Reactive Compensation Bead Kit

ArC Amine Reactive Compensation Bead Kit ArC Amine Reactive Compensation Bead Kit Catalog no. A1346 Table 1. Contents and storage information. Material Amount Composition Storage Stability ArC reactive beads (Component A) ArC negative beads (Component

More information

How To Install A Gel Doc Xr+ Camera On A Computer Or Mouse Or Tv (For A Powerbook) With A Zoom Lens (For An Ipa) With An Iphone Or Ipa (For Mac) With The Zoom Lens

How To Install A Gel Doc Xr+ Camera On A Computer Or Mouse Or Tv (For A Powerbook) With A Zoom Lens (For An Ipa) With An Iphone Or Ipa (For Mac) With The Zoom Lens Molecular Imager Gel Doc XR+ Installation Guide To install your Gel Doc XR+, perform these seven steps in the following order: 1. Unpack the Gel Doc XR+ system. 2. Install Image Lab software. 3. Set up

More information

Milwaukee USER MANUAL. Milwaukee. Smart DO Meter PORTABLE DISSOLVED OXYGEN METER MODEL: SM600. Authorized Dealer: ISMIL600 11/01

Milwaukee USER MANUAL. Milwaukee. Smart DO Meter PORTABLE DISSOLVED OXYGEN METER MODEL: SM600. Authorized Dealer: ISMIL600 11/01 Milwaukee Milwaukee USER MANUAL PORTABLE DISSOLVED OXYGEN METER MODEL: SM600 Smart DO Meter Authorized Dealer: ISMIL600 11/01 PROBE PREPARATION: The meter is supplied with a 9V battery. Slide off the battery

More information

Agilent E5063A ENA Series Network Analyzer

Agilent E5063A ENA Series Network Analyzer Agilent E5063A ENA Series Network Analyzer 100 khz to 4.5/ 8.5/18 GHz Configuration Guide Ordering Guide The following steps will guide you through configuring your E5063A. Standard furnished item Description

More information

User Guide. Heavy Duty Dissolved Oxygen Meter. Model 407510

User Guide. Heavy Duty Dissolved Oxygen Meter. Model 407510 User Guide Heavy Duty Dissolved Oxygen Meter Model 407510 Introduction Congratulations on your purchase of Extech's Heavy Duty Dissolved Oxygen / Temperature Meter which simultaneously displays Dissolved

More information

73 Series Spectrophotometers

73 Series Spectrophotometers 73 Series Spectrophotometers The 73 series introduces four new spectrophotometers to the extensive Jenway range. These spectrophotometers use icon driven software and have an improved navigation system

More information

Creatine Kinase Activity Colorimetric Assay Kit ABE5487 100 assays; Store at -20 C

Creatine Kinase Activity Colorimetric Assay Kit ABE5487 100 assays; Store at -20 C Creatine Kinase Activity Colorimetric Assay Kit ABE5487 100 assays; Store at -20 C I. Introduction: Creatine Kinase (CK) also known as creatine phosphokinase (CPK) and ATP: creatine N- phosphotransferase

More information

How To Build A Powerline Box Powerline Generator

How To Build A Powerline Box Powerline Generator Quick Reference Guide DYNAMIC Series Dynamic Series is a broad product family that provides connector solutions ranging from signal level circuitry through power circuit connectivity in a ruggedized, industrialized

More information

ORGANIC SAMPLE PREPARATION

ORGANIC SAMPLE PREPARATION ORGANIC SAMPLE PREPARATION W W W.LA BT E C H S R L.CO M WSPE MANUAL VACUUM MANIFOLD SPE Process control of the flow rate is critical to guarantee reproducible extractions. Differently then any other systems,

More information

How To Control A Record System

How To Control A Record System Thermo Scientific Qtegra Intelligent Scientific Data Solution (ISDS) Software for 21 CFR Part 11 Compliant Laboratories Technical Note 43106 Key Words Compliance, Electronic Records, 21 CFR Part 11 Goal

More information

ExStik TM ph Waterproof Meters

ExStik TM ph Waterproof Meters User Guide ExStik TM ph Waterproof Meters Models PH100 & PH110 Patent Pending ExStik TM Description Front Panel Controls 1. Battery compartment cap 2. LCD Display 3. MODE / HOLD button 4. CAL / RECALL

More information

Lab 2 Biochemistry. Learning Objectives. Introduction. Lipid Structure and Role in Food. The lab has the following learning objectives.

Lab 2 Biochemistry. Learning Objectives. Introduction. Lipid Structure and Role in Food. The lab has the following learning objectives. 1 Lab 2 Biochemistry Learning Objectives The lab has the following learning objectives. Investigate the role of double bonding in fatty acids, through models. Developing a calibration curve for a Benedict

More information

Agilent Mobile WiMAX R&D Test Set Solutions: Software and Technical Support Contract

Agilent Mobile WiMAX R&D Test Set Solutions: Software and Technical Support Contract Agilent Mobile WiMAX R&D Test Set Solutions: Software and Technical Support Contract Product Overview Maximize the potential of the E6651A Mobile WiMAX test set and related software with the latest software

More information

CNE Progress Chart (CNE Certification Requirements and Test Numbers) (updated 18 October 2000)

CNE Progress Chart (CNE Certification Requirements and Test Numbers) (updated 18 October 2000) Novell Education CNE Progress Chart (CNE Certification Requirements and Test Numbers) (updated 18 October 2000) Prerequisite for all certifications In order to receive a Novell certification the candidate

More information

Agilent U2000 Series USB Power Sensors

Agilent U2000 Series USB Power Sensors Agilent U2000 Series USB Power Sensors Single/Multi-Channel Power Measurement Simple Setup Affordable Demo Guide Table of Contents Introduction 2 The Agilent N1918A Power 3 Analysis Manager Demonstration

More information

ArtisanLink Staining System is an automated special stains slide

ArtisanLink Staining System is an automated special stains slide Technical Tips Tips on using the ArtisanLink Special Staining System Jamie Nowacek, BS, HT(ASCP) CM, QIHC, PMP Dako North America, Inc. Carpinteria, CA, USA ArtisanLink Staining System is an automated

More information

Mouse Keyhole Limpet Hemocyanin antibody(igm) ELISA Kit

Mouse Keyhole Limpet Hemocyanin antibody(igm) ELISA Kit Mouse Keyhole Limpet Hemocyanin antibody(igm) ELISA Kit Catalog No. MBS702810 (96 tests) This immunoassay kit allows for the in vitro semi-quantitative determination of mouse KLH(IgM)antibody concentrations

More information

ab204067-vacuum manifold for 96 well filter plates This product is for research use only and is not intended for diagnostic use.

ab204067-vacuum manifold for 96 well filter plates This product is for research use only and is not intended for diagnostic use. ab204067-vacuum manifold for 96 well filter plates This product is for research use only and is not intended for diagnostic use. Version 2 Last Updated 06 November 2015 Table of Contents INTRODUCTION 1.

More information

Agilent N5970A Interactive Functional Test Software: Installation and Getting Started

Agilent N5970A Interactive Functional Test Software: Installation and Getting Started Agilent N5970A Interactive Functional Test Software: Installation and Getting Started Application Note The N5970A Interactive Functional Test Software along with the 8960 Series 10 (E5515C) wireless communications

More information

White Paper. 10 Reasons to Choose Image-based Barcode Readers

White Paper. 10 Reasons to Choose Image-based Barcode Readers White Paper 10 Reasons to Choose Image-based Barcode Readers Introduction Image-based barcode readers are rapidly replacing laser scanners in a wide range of industries including food, beverage, consumer

More information

Esterification Method 1 Method 8196 27 to 2800 mg/l (as acetic acid) Reagent Solution

Esterification Method 1 Method 8196 27 to 2800 mg/l (as acetic acid) Reagent Solution Volatile Acids DOC316.53.01144 Esterification Method 1 Method 8196 27 to 2800 mg/l (as acetic acid) Reagent Solution Scope and application: For digestor sludges. 1 Adapted from The Analyst, 87, 949 (1962).

More information

Thermo Scientific Dionex Chromeleon 7 Chromatography Data System Software

Thermo Scientific Dionex Chromeleon 7 Chromatography Data System Software Thermo Scientific Dionex Chromeleon 7 Chromatography Data System Software Frank Tontala, Thermo Fisher Scientific, Germering, Germany Technical Note 708 Key Words Chromeleon Chromatography Data System,

More information

ENGLISH USER S MANUAL. compact handheld 1D/2D code scanner

ENGLISH USER S MANUAL. compact handheld 1D/2D code scanner ENGLISH USER S MANUAL compact handheld 1D/D code scanner 11175-en-GB 5J006 04 006 1 3 A B 4 C INSTALLATION INSTRUCTIONS FIRST STEP: TURN POWER OFF! Exercise caution at all times when working with AC and

More information

The Determination of an Equilibrium Constant

The Determination of an Equilibrium Constant The Determination of an Equilibrium Constant Computer 10 Chemical reactions occur to reach a state of equilibrium. The equilibrium state can be characterized by quantitatively defining its equilibrium

More information

cobas c 111 analyzer Small box. Big performance

cobas c 111 analyzer Small box. Big performance cobas c 111 analyzer Small box. Big performance His journey back to health begins in your laboratory cobas solutions making a difference when it matters most Every patient prognosis depends on several

More information

[ Care and Use Manual ]

[ Care and Use Manual ] The Waters GPC Cleanup System uses two Envirogel GPC Cleanup Columns to perform routine cleanup of environmental samples as specified by EPA Method 3640A, GPC Cleanup. The columns, 19 x 150 mm and 19 x

More information

Thermo Scientific Barnstead TII Pure Water Systems. Pure water. Pure research. Total confidence.

Thermo Scientific Barnstead TII Pure Water Systems. Pure water. Pure research. Total confidence. Thermo Scientific Barnstead TII Pure Water Systems Pure water. Pure research. Total confidence. Thermo Scientific Barnstead TII Pure Water Systems Ideal for any daily application needs for pure water,

More information

ELECTROCHEMISTRY. BOECO ELECTRODES The electrodes are not included with the ph meters and have to be ordered separately:

ELECTROCHEMISTRY. BOECO ELECTRODES The electrodes are not included with the ph meters and have to be ordered separately: BOECO PORTABLE PH/ORP/TEMP METER MODEL PT-380 A Simultaneous displays ph or mv and temperature. A Convenient calibration with automatic buffer recognition of European and US buffer sets. Calibration data

More information

Thermo Scientific PepFinder Software A New Paradigm for Peptide Mapping

Thermo Scientific PepFinder Software A New Paradigm for Peptide Mapping Thermo Scientific PepFinder Software A New Paradigm for Peptide Mapping For Conclusive Characterization of Biologics Deep Protein Characterization Is Crucial Pharmaceuticals have historically been small

More information

High-Speed Inter Connect (HSIC) Solution

High-Speed Inter Connect (HSIC) Solution High-Speed Inter Connect (HSIC) Solution HSIC Essentials Datasheet Protocol Decode Protocol decode Saves test time and resource costs. Designed for use with the MSO/DPO5000, DPO7000C, DPO/DSA/MSO70000C,

More information

ph and Acidity in Wine and Fruit Juice

ph and Acidity in Wine and Fruit Juice ph and Acidity in Wine and Fruit Juice DOC316.52.93089 Endpoint potentiometric titration Scope and application: Wine and fruit juice 1. Introduction This working procedure refers to the titration of total

More information

1.5 GHz Active Probe TAP1500 Datasheet

1.5 GHz Active Probe TAP1500 Datasheet 1.5 GHz Active Probe TAP1500 Datasheet Easy to use Connects directly to oscilloscopes with the TekVPI probe interface Provides automatic units scaling and readout on the oscilloscope display Easy access

More information

510(k) SUBSTANTIAL EQUIVALENCE DETERMINATION DECISION SUMMARY

510(k) SUBSTANTIAL EQUIVALENCE DETERMINATION DECISION SUMMARY A. 510(k) Number: K092353 510(k) SUBSTANTIAL EQUIVALENCE DETERMINATION DECISION SUMMARY B. Purpose for Submission: This is a new 510k application for a new indication for the MONOLISA Anti-HAV IgM EIA

More information

Nitrogen, Ammonia. Known Addition ISE Method 1 Method 10002 Minimum of 0.8 mg/l NH 3 N. Ammonia ISE. Test preparation. Instrument-specific table

Nitrogen, Ammonia. Known Addition ISE Method 1 Method 10002 Minimum of 0.8 mg/l NH 3 N. Ammonia ISE. Test preparation. Instrument-specific table Nitrogen, Ammonia DOC316.53.01234 Known Addition ISE Method 1 Method 10002 Minimum of 0.8 mg/l NH 3 N Scope and application: For wastewater 2. Ammonia ISE 1 Adapted from the Standard Methods for the Examination

More information

Application Note. USD 2995 (a) High Throughput Regeneration Study on MEP HyperCel Mixed-Mode Sorbent on ScreenExpert RoboColumns u

Application Note. USD 2995 (a) High Throughput Regeneration Study on MEP HyperCel Mixed-Mode Sorbent on ScreenExpert RoboColumns u Application Note USD 2995 (a) High Throughput Regeneration Study on MEP HyperCel Mixed-Mode Sorbent on ScreenExpert RoboColumns u Summary A regeneration study of MEP HyperCel mixed-mode sorbent was conducted

More information