1 Radiant Barrier Fact Sheet Overview Radiant barriers and interior radiation control coatings are designed to work in your attic to keep some of the heat from the sun away from your living space. For homes with air-conditioning ductwork in the attic in the deep south (such as in Miami in Zone 1 or Austin in Zone 2 in the map below), radiant barriers could reduce your utility bills by as much as $150 per year using average residential electricity prices. If you re able to participate in one of the Time of Day rate plans, your savings can be even greater (almost $200 per year under the current Miami Time of Day rate plan). For milder climates, like those in Atlanta and Baltimore, annual energy savings will be about half those of their southern neighbors. In the northern climate zones, the savings drops further, going from about $40 to $10 per year as you go from Chicago to Fairbanks. Contents: Overview What is a radiant barrier? What is an interior radiation control coating? How do radiation barriers save energy? Why does it matter whether there is air-conditioning ductwork in the attic? Radiant barriers are one component in the attic system After you ve decided to install a radiant barrier product Installation options Important Non-Energy Considerations More about heat transfer in attics Where to go for more information Glossary About this Fact Sheet Appendix: Background information about radiant barriers and the analysis used to prepare this Fact Sheet Have energy savings been measured? How did we estimate the savings shown in this fact sheet? References If there are no ducts or air handlers in the attic, the savings are much less, going from about $20 per year in Miami to $5 per year in Baltimore, but a radiant barrier may still help to improve comfort and to reduce the peak airconditioning load.
2 What is a radiant barrier? Radiant barriers consist of a thin layer of a highly reflective material, usually aluminum, applied to one or both sides of another material that provides strength and durability. These other materials include kraft paper, plastic films, cardboard, plywood or oriented strand board (OSB) sheathing, and air infiltration barrier material. Be sure that the label indicates that the product emittance is less than 0.1, as measured by ASTM C1371. (Please see the Glossary for definitions of many terms used in this fact sheet.) What is an interior radiation control coating? An interior radiation control coating is a liquid that is spray-applied to the underside of a roof system. The coating must be applied at a certain thickness, perhaps over a primer coating, to provide the desired performance. Be sure that the label indicates that the product emittance is less than 0.25 as measured by ASTM C1371. Many interior coating products have names that sound like a radiation control coating, but unless the label shows the emittance is between 0 and 0.25, they won t perform as intended. The rest of this article will refer to radiant barriers, but interior radiation control coatings may apply in many cases. Savings for these coatings may be a little less due to higher emissivity, but that may be counter-balanced if the coatings cover more of the exposed surface than a radiant barrier. Photos courtesy of the Reflective Insulation Manufacturers Association International ( Many interior coating products have names that sound like a radiation control coating, but unless the label shows the emittance is between 0 and 0.25, they won t perform as intended. If you are a homeowner considering radiant barriers, please read: How do radiation barriers save energy? o Why does it matter whether there is air-conditioning ductwork in the attic? Radiant barriers are one component in the attic system If you ve decided to install a radiant barrier product o Installation options o Important non-energy considerations 2
3 If you want to learn more about radiant barriers, please read: More about heat transfer in attics o Have energy savings been measured? o How did we estimate the savings shown in this fact sheet? Radiant barriers can be used in residential, commercial, and industrial buildings. However, this fact sheet was developed only for radiant barriers in ventilated attics of residential buildings. For information on other applications, see Where to go for more information. How do radiation barriers save energy? On a sunny summer day, solar energy is absorbed by the roof, heating the roof sheathing and causing the underside of the sheathing and the roof framing to become hot. These surfaces then radiate heat downward toward the attic floor. Radiant barriers reduce that energy flow. Since the amount of heat radiation striking the top of the insulation is less than it would have been, the insulation surface temperature is lower and the heat flow through the insulation is reduced. By reducing the energy reaching the attic floor, radiant barriers also reduce the attic air temperature. The amount of energy exchanged between the roof deck and the attic floor depends on two factors. The temperatures of each surface The properties of the attic surface materials, called the "emittance" and reflectivity. Energy exchange is greatest when the temperature difference is high, when the emittance is high, and when the reflectivity is low. The underside of a roof deck made of wood will typically have a high emittance. When a radiant barrier with a much lower emittance covers that wooden surface, the thermal radiation is reduced. When a radiant barrier with a high reflectivity is placed on top of the attic floor insulation, much of the heat radiated from the hot roof is reflected back toward the roof. In the winter, radiant barriers can reduce indoor heat losses through the ceiling, especially during winter nights when the roof surface is coldest. However, they also reduce beneficial daytime heat gains due to solar heating of the roof. Depending on your climate, level of attic insulation, and other factors, the net winter effect can be positive or negative. 3
4 Why does it matter whether there is air-conditioning ductwork in the attic? Radiant barriers reduce energy losses from air conditioning ductwork in the attic in three ways. First, the outside surface of any ductwork located in the attic exchanges thermal radiation energy with the roof deck in the same way as the attic floor. Because the temperature difference between the roof deck and the duct surface is even greater than that between the roof deck and attic floor, this thermal radiation is significant. Second, the outside surface of the ductwork exchanges energy with the air in the attic space, and that energy loss is reduced when the attic temperature is moderated by the radiant barrier. Third, ducts leak. When return ducts leak, the air that is sucked into the ducts through the leaks feeds into your HVAC air handler, which then has to use extra energy to cool this warmer air. When the capacity of the HVAC system is nearing its limit, as on very hot summer days, this can make a noticeable difference in the comfort within the house. (When supply ducts leak, the air you ve paid to condition goes into your attic and out with the attic ventilation. Furthermore, this diversion of the supply air can reduce the pressure inside your home, so that more outside air is pulled into any existing openings, such as cracks around windows and doors and openings between the attic and the conditioned space.) So in both cases, sealing up duct leaks can improve comfort and save energy. Radiant barriers are one component in the attic system Your attic is a complex system where many components work together to maintain comfortable (and dry!) indoor conditions, so you can increase your savings by considering the whole attic system. The radiant barriers reduce radiant energy transfer. Insulation on the attic floor reduces conductive and convective heat transfer. The duct insulation reduces conductive and convective heat transfer at the duct surface. Duct sealing reduces the energy losses caused by increased air exchange between the inside and outside of your home. Special shingles or ventilation arrangements can reduce the amount of energy that enters the attic from the outside. 4
5 So, when you consider a radiant barrier, look at the whole attic system. We calculated the first year savings for a 1,540 square foot attic for several combinations of attic improvements: adding a radiant barrier, reducing duct energy Reducing any air leaks between your house and the attic, that is, through the ceiling or inside any wall cavities, is also important and should be the first step in any attic improvement effort. (see losses, and upgrading insulation from R19 to code levels. The results shown here were based on a number of assumptions and won t represent your house exactly. (The assumptions and methodology are discussed later in this fact sheet.) For example, if your home heating and cooling system has a lower efficiency than the efficiency used in these calculations, then your savings will be greater (until you replace the air conditioner). Comparing the different system improvement options is easier if you look at this bar chart. The greatest savings are available to homes with uninsulated, or poorly insulated, ducts in the attic (the values are also given below in tables for folks who don t like graphs). Research has shown that any Calculated annual savings for a 1,540 ft 2 house in eight climate zones (RB = Radiant Barrier) Original Attic $0 $400 $800 $1,200 $1,600 Conditions Add RB, improve ducts, add insulation Uninsulated Ducts Insulated Ducts No Ducts Code R19 Code R19 Code R19 Add RB, improve ducts Add RB, add insulation Add RB Add RB, improve ducts Add RB Add RB, add insulation Add RB Add RB Add RB, add insulation Add RB Add RB Miami (Zone 1) Austin (Zone 2) Atlanta (Zone 3) Baltimore (Zone 4) Chicago (Zone 5) Minneapolis (Zone 6) Fargo (Zone 7) Fairbanks (Zone 8) duct system that hasn t been subjected to a formal testing process leaks, it s just a question of how much. These homes with the greatest savings potential are also likely to be homes with higher energy bills. If your ducts are already well sealed, or even better, not located in the attic at all, your savings potential is less because you re starting with an attic that is already more efficient. 5
6 Calculated annual savings for a 1,540-ft2 house with uninsulated ducts in the attic Original attic condition R19 Attic Insulation Code-level Attic Insulation Attic system Add RB, Add RB, Add RB, Add Add RB, Add RB modification improve ducts, add insulation improve ducts add insulation RB improve ducts Miami (1) $460 $430 $180 $140 $410 $120 Austin (2) $730 $670 $240 $150 $610 $120 Atlanta (3) $670 $600 $200 $80 $540 $70 Baltimore (4) $1,210 $1,070 $320 $80 $950 $60 Chicago (5) $1,150 $1,020 $280 $60 $910 $40 Minneapolis (6) $1,250 $1,080 $300 $45 $970 $25 Fargo (7) $1,080 $940 $260 $35 $830 $15 Fairbanks (8) $1,540 $1,340 $300 $25 $1,240 $0 Calculated annual savings for a 1,540 ft 2 house with well-insulated and sealed ducts, or no ducts, in the attic Original attic condition Attic system modification Insulated and well-sealed ducts R19 Attic Insulation Code-level Attic Insulation Add RB, add insulation Add RB Add RB Add RB, add insulation No ducts R19 Attic Insulation Add RB Code-level Attic Insulation Add RB Miami (1) $75 $50 $40 $40 $20 $15 Austin (2) $110 $50 $40 $60 $20 $15 Atlanta (3) $100 $30 $25 $55 $15 $10 Baltimore (4) $170 $30 $20 $120 $10 $5 Chicago (5) $150 $20 $15 $110 $5 $5 Minneapolis (6) $180 $20 $10 $140 $5 $0 Fargo (7) $150 $15 $10 $120 $0 $0 Fairbanks (8) $210 $15 $10 $180 $5 $0 Selecting your best approach will depend on your house s configuration, including physical attic constraints, and your budget. For a shallow attic, it may not be possible to add conventional insulation, so a radiant barrier alone may be the best choice. If you already have a higher level of insulation in your attic (R-30 or more in the south, R-38 or more in the middle and northern climates), then adding attic insulation would not be your first choice. If your ducts are not in the attic, or if they are already well-sealed and insulated, then improving the ductwork will not be an effective choice. But in any case, addressing and improving the whole attic as a system will give you the greatest savings. (See The annual savings are calculated by comparing the hourly energy consumption of attics with two different configurations. Another way to look at the issue is to look at the calculated annual cost for the total heating and cooling energy lost through the attic floor AND ducts located in the attic. Because we calculate the energy exchange for every hour during a year, we can also show the impact 6
7 of Time-of-Day rates that are available to some homes in Miami and Austin. The figure below shows the cost we calculated for that energy for a 1,540-ft 2 house for both time-of-day (from October 2010) and 2008 state average energy prices. In Miami, the savings due to installing a radiant barrier were about 35% greater with time of day pricing than with average pricing; in Austin they were only about 5% greater. (Also, if you re considering participation in a time-of-day rate plan, remember that this only represents a portion of your total utility bill, and the effect of your appliance use schedule will also play an important role.) Calculated annual cost for energy lost through the attic floor PLUS the energy lost due to ducts located in the attic. Looking at this figure, the most important message is for anyone building a new home even if it costs more don t put the ducts in the attic! For all the attic system elements, you need to compare the potential savings over many years to the installed cost. The next two tables give you the annual savings per square foot, one for homes with uninsulated ducts in the attic, and one for homes with well-insulated and sealed ducts, or no ducts at all, in the attic. You can estimate a reasonable purchase price by multiplying the values in the table by the size of your attic floor Conventional insulations are usually rated by their R-value. Since the performance of radiant barriers depends on many variables, simple R-value ratings do not apply. 7
8 and then multiplying that by ~15. (This simple 15-year payback is approximately the same as the present value of your energy savings over the next 20 years, for a reasonable rate-of-return value of 2 to 3%, and assuming that energy prices don t go up faster than inflation. You could multiply the annual savings by ~20 if you want to consider the present value of savings over the next 30 years.) We don t know what will happen to energy prices in the future, but if you think your energy prices will increase above the general inflation rate, then your savings in future years will be even greater than the firstyear savings shown here. Calculated annual savings per ft 2 with uninsulated ducts in the attic (Values with Time-of-Day pricing shown for zones 1 and 2) Zone Add RB, improve ducts, add insulation R19 Attic Insulation Add RB, improve ducts Add RB, add insulation Add RB Code-level Attic Insulation Add RB, Add RB improve ducts Miami (1) $0.30 ($0.38) $0.28($0.36) $0.11($0.15) $0.09($0.12) $0.26($0.34) $0.08($0.11) Austin (2) $0.47($0.34) $0.44($0.31) $0.16($0.13) $0.09($0.10) $0.39($0.29) $0.08($0.08) Atlanta (3) $0.43 $0.39 $0.13 $0.05 $0.35 $0.05 Baltimore (4) $0.78 $0.69 $0.21 $0.05 $0.61 $0.04 Chicago (5) $0.75 $0.66 $0.18 $0.04 $0.59 $0.03 Minneapolis (6) $0.81 $0.70 $0.19 $0.03 $0.63 $0.02 Fargo (7) $0.70 $0.61 $0.17 $0.02 $0.54 $0.01 Fairbanks (8) $1.00 $0.87 $0.20 $0.02 $0.80 $0.00 Calculated annual savings per ft 2 with well-insulated and sealed ducts, or no ducts, in the attic (Values with Time-of-Day pricing shown for zones 1 and 2) Zone Insulated and well-sealed ducts R19 Attic Insulation Code insulation, Add RB, add insulation Add RB Add RB Add RB, add insulation No ducts R19 Attic Insulation Add RB Code-level Attic Insulation Add RB Miami (1) $0.05($0.06) $0.03($0.04) $0.03($0.04) $0.03($0.04) $0.01($0.02) $0.01($0.01) Austin (2) $0.07($0.05) $0.03($0.03) $0.03($0.03) $0.04($0.03) $0.01($0.01) $0.01($0.01) Atlanta (3) $0.06 $0.02 $0.02 $0.04 $0.01 $0.01 Baltimore (4) $0.11 $0.02 $0.01 $0.07 $0.01 $0.00 Chicago (5) $0.10 $0.01 $0.01 $0.07 $0.00 $0.00 Minneapolis $0.12 $0.01 $0.01 $0.09 $0.00 $0.00 (6) Fargo (7) $0.10 $0.01 $0.01 $0.07 $0.00 $0.00 Fairbanks (8) $0.14 $0.01 $0.01 $0.11 $0.00 $0.00 For example, if you lived in a 2000 ft 2 house in Miami, had R19 attic insulation, and the ductwork in your attic was poorly insulated, then you could save ~$0.28/ft 2, or $560 per year by adding a radiant barrier and sealing and insulating the ducts. The present value of those savings over a 20-year period 8
9 would then be about $8,400. If the price to make these modifications were less than that value, then this would be an economical choice. Radiant barrier, coatings, and insulation costs vary widely. As with most purchases, some comparison shopping can save you money. Get prices from multiple contractors, or multiple stores if you re going to do the installation yourself. You should always check with your local or state energy office or building code department for current insulation recommendations or see the Insulation Fact Sheet or the ZipCode Calculator ( or ) Costs will depend on several factors, including: Homeowner- or contractor-installation. New home or existing home. What extra "features" are desired; e.g., a radiant barrier with perforations and reinforcements may be more expensive than a "basic" radiant barrier. Any necessary retrofit measures such as adding venting (soffit, ridge, etc.) Type of radiant barrier selected, or type of insulation selected (loose-fill insulation is usually lower in price than "batt" insulation or blown foam insulation) Installation location and coverage Region of the country After you ve decided to install a radiant barrier product After considering the options and deciding to use a radiant barrier in your attic, there are several things you should do to optimize the performance. Most important, you must insure that the installation follows all the guidelines and recommendations provided by the manufacturer. Other guidance is provided in two ASTM Standard Practices for the installation of radiant barriers. Find out if your contractor follows these practices. (ASTM C1321 and C1158) If a radiant barrier is reflective on only one side, the reflective side must face toward the main attic space, regardless of whether the radiant barrier is at the rafters or the attic floor. To obtain the best performance with both radiant barriers, the gable ends of the attic should also be covered, but do not cover the gable vent area. For attics that are open to the space over garages or carports, the radiant barrier should extend eight feet or more into the garage or carport to achieve the same effect. It is not necessary to cover the gable ends if a radiant barrier is placed on top the attic floor insulation. If a radiant barrier is reflective on only one side, the reflective side must face toward the main attic space, regardless of whether the radiant barrier is at the rafters or the attic floor. While working in the attic to install a radiant barrier, care should be taken not to compress existing insulation present in the attic. The effectiveness of the existing insulation is dependent upon its thickness, so if it is compressed, its R-value is decreased. If you select a radiant barrier product, you have several installation location options described in the next section. If you select an interior radiation control coating, you should be sure that the application covers ALL the roof support structure connected to the roof deck. 9
10 Installation options Most residential roofs provide some type of attic or airspace that can accommodate an effective radiant barrier system. In new residential construction, it is fairly easy to install a radiant barrier system. The following images show five possible locations for the installation of an attic radiant barrier system. Location 1, where the radiant barrier material is pre-applied to the roof decking (you can purchase radiant barrier decking), is appropriate if you are building a new house or if you are replacing your roof decking for other reasons. Location 2 may offer advantages to the builder during construction of a new house. Before the roof sheathing is applied, the radiant barrier is draped over the rafters or trusses in a way that allows the product to droop 1-1/2 to 3 inches between each rafter. In Locations 3 and 4, the radiant barrier is attached to either the faces or bottoms of the rafters or top chords of the roof trusses. Locations 3 and 4 may be used with either new construction, or with retrofit of an existing house. 10
11 Location 4 In Location 5, the radiant barrier is laid out on the attic floor over the top of existing attic insulation. (See the discussion for important information about performance problems associated with dust for this option.) With either Location 2, 3 or 4, the space between the roof sheathing and the radiant barrier provides a channel through which warm air can move freely. For any of the radiant barrier locations (and for attics without radiant barriers), ideal venting would provide equal areas on intake (soffit) and exhaust (gable or ridge) vents. For proper air flow, with a roof-mounted radiant barrier, a gap of approximately 3 inches should be left between the radiant barrier and the insulation, and a gap of at least 6 inches should be left near the ridge. Both of these gaps should be left for attics with either ridge or gable venting. 11
12 Even though some testing shows that a brand new application in location 5, the attic floor, will work better than the roof applications, there are several drawbacks to this location. The attic floor application is most susceptible to accumulation of dust, while downward facing reflective surfaces used with many roof applications are not likely to become dusty. After a long enough period of time, a dusty attic floor application will lose much of its effectiveness. Predictive modeling results, based on testing, suggest that a dusty attic floor application will lose about half of its effectiveness after about one to ten years. For this location, moisture (see below) issues must also be considered. The floor location is not appropriate when a large part of the attic is used for storage, since the radiant barrier surface must be exposed to the attic space. Also, kitchen and bathroom vents and recessed lights should not be covered with the radiant barrier. If a one-sided radiant barrier is laid on top of the insulation with the reflective side facing down and touching the insulation, the radiant barrier will lose most of its effectiveness in reducing heating and cooling loads. Important Non-Energy Considerations Potential for moisture condensation Condensation can be a concern when a radiant barrier is installed on the attic floor directly on top of conventional insulation. During cold weather, water vapor from the interior of a house may move into the attic. In most cases, this water vapor will not cause any problem because attic ventilation will carry excess vapor away. But, during cold weather, a radiant barrier on top of the insulation could cause water vapor to condense and even freeze on the barrier's underside. A radiant barrier used in the attic floor application must therefore allow water vapor to pass through it. Some allow water vapor passage through holes or perforations, while others are naturally permeable. Some testing has been performed to determine the potential for moisture condensation with perforated radiant barriers laid on top of the insulation. A test was conducted during the winter in Climate Zone 4, using houses that were operated at much higher-than-normal indoor relative humidities. Since this testing did not reveal any significant moisture condensation problems, it is expected that moisture condensation will not be a problem in warmer climates. Attic ventilation Attic ventilation helps to cool your attic in the summer and to remove excess water vapor in winter. Unfortunately, specific recommendations for the best type and amount of attic ventilation for use with radiant barriers are not available. Where no ridge or gable vents exist, it is recommended that one or the other be installed. Always check existing ridge vent systems to ensure that roofing paper is not blocking the vent opening, and check the soffit vents to ensure that they have not been covered with insulation. Effect of radiant barriers on roof temperatures Field tests have shown that radiant barriers can cause a small increase in roof temperatures. Roof mounted radiant barriers may increase shingle temperatures by 2 to 10 o F, while radiant barriers on the attic floor may cause smaller increases of 2 o F or less. The effects of these increased temperatures on roof life, if any, are not known. Some shingle manufacturers will not warrant their shingle with a radiant barrier whereas others will. Check with the manufacturer before selecting a shingle for a new roof. 12
13 Fire ratings The fire ratings of radiant barriers are important because flame and smoke characteristics of materials exposed to ambient air are critical. To obtain these ratings, a material must have an ASTM E-84 Flame Spread Index test and the resulting rating must be printed on the product. Rating requirements vary depending upon whether or not the attic is accessible and may also vary from one code jurisdiction to another. You should check to see what rating your local building code requires. Other safety considerations The installer should wear proper clothing and equipment as recommended by the radiant barrier manufacturer. Handling conventional insulation may cause skin, eye, and respiratory system irritation. If in doubt about the effects of the insulation, protective clothing, gloves, eye protection, and breathing protection should be worn. Be especially careful with electrical wiring, particularly around junction boxes and old wiring. Never staple through, near, or over electrical wiring. Repair any obvious frayed or defective wiring in advance of radiant barrier installation. Work in the attic only when temperatures are reasonable. Work with a partner. Not only does it make the job go faster, it also means that you'll have assistance should a problem occur. If the attic is unfinished, watch where you walk. If you step in the wrong place, you could fall through the ceiling. Step and stand only on the attic joists or trusses or the center of a strong moveable working surface. Watch your head. In most attics, roofing nails penetrate through the underside of the roof. A hard hat may be of some use. Make sure that the attic space is well ventilated and lighted. Do not cover any recessed lights or vents with radiant barrier material (attic floor application). More about heat transfer in attics Radiant barriers and conventional insulation both reduce cooling bills by reducing the amount of heat that is transferred from the attic into the house. They differ in the way they reduce the heat flow. Conventional insulation traps air within the insulation, reducing heat transfer by air movement (convection). The insulation fibers or particles also partially block radiation heat transfer through the space occupied by the insulation. A radiant barrier reduces the amount of heat radiated across an open air space next to the radiant barrier. The performance of a radiant barrier depends on two material properties, the emittance and the reflectivity. The emittance (also called the emissivity) is the property that determines how well a radiant barrier will perform. This property is a number between 0 and 1, with lower numbers indicating better potential for performance Radiant barrier materials must have high reflectivity (usually 0.9, or 90%, or more) and low emittance (usually 0.1 or less), and must face an open air space to perform properly. Interior radiation control coatings must have a low emittance (usually 0.25 or less), and must face an open air space to perform properly. 13
14 The effective emittance and reflectivity of a radiant barrier in an attic environment may change if the surface gets dirty or is torn. If the surface is dirty, the performance and energy savings may be cut in half. because the lower the emittance, the lesser the emitted radiation. It is not always possible to judge the emittance by visual appearance, as the heat transfer is longwave radiation and not visible radiation. There are materials than can appear to be shiny and aluminum colored, but may be coated such that they actually have high emissivity. Measured emittance values should be part of the information provided by the manufacturer. A closely related material property is the "reflectance" (also called the "reflectivity"). This is a measure of how much radiant heat is reflected by a material. The reflectivity is also a number between 0 and 1 (sometimes, it is given as a percentage, and then it is between 0 and 100%). For a material that is opaque (that is, it does not allow radiation to pass directly through it), the emittance and reflectivity add up to one. Hence, a material with a high reflectivity has a low emittance, and vice versa. Again, the reflectivity of concern is in the longwave spectrum and thus how reflective it appears based upon the part of the light spectrum that humans can see is not applicable. Where to go for more information Web Sites ASTM DOE program FSEC Insulation Fact Sheet ORNL RIMA Glossary ASTM ASTM C1158 ASTM C1313 ASTM C1321 DOE Emittance and emissivity FSEC American Society for Testing and Materials Standard Practice for Installation and Use of Radiant Barrier Systems (RBS) in Building Construction Standard Specification for Sheet Radiant Barriers for Building Construction Applications Standard Practice for Installation and Use of Interior Radiation Control Coating Systems (IRCCS) in Building Construction U.S. Department of Energy The emittance (sometimes called the emissivity) is the ability of a material to release heat by radiation. Emittance is expressed as a number between 0 and 1, with lower numbers indicating less heat radiation and numbers close to one greater heat radiation. Dull black materials will usually have an emittance close to 1 and shiny materials will usually have a low emittance, but it is not always possible to judge the emittance just by visual appearance. Florida Solar Energy Center 14
15 gal. KWH ORNL Present Value Reflectance and reflectivity RIMA gallon Kilowatt-hour(of electricity) Oak Ridge National Laboratory The amount of money it would take today to generate a future series of payments. The present value is determined by the rate-of-return, the number of payments in the series, and the size of each payment. The rate-of-return represents the interest you could earn on an alternative investment over an above the general inflation rate. The reflectance (sometimes called the reflectivity) is a measure of how much radiant heat that hits a material is reflected. The reflectance is a number between 0 and 1, with lower numbers indicating less heat reflection and numbers close to one greater heat reflection. Sometimes the reflectance is given as a percentage, and then it is between 0 and 100%. Reflective Insulation Manufacturers Association About this Fact Sheet LEGAL NOTICE This document was prepared by the Oak Ridge National Laboratory (ORNL) as part of work sponsored by the United States Department of Energy (DOE) in carrying out their statutory authorities. Neither ORNL, DOE, the United States Government, nor any of their agents or employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise, does not necessarily constitute or imply its endorsement, recommendation, or favoring by ORNL, DOE, the United States Government, or any of their agents or employees. The views and opinions of the authors expressed herein do not necessarily state or reflect those of ORNL, DOE, or the United States Government or any agency thereof. This fact sheet was prepared by the Building Envelope Research Program Oak Ridge National Laboratory For more information, contact the program manager for Building Envelope Research: André O. Desjarlais Oak Ridge National Laboratory P. O. Box 2008, MS 6070 Oak Ridge, TN [email protected] 15
16 Appendix: Background information about radiant barriers and the analysis used to prepare this Fact Sheet We know that radiant barriers save energy under certain conditions because there have been extensive tests and analysis. Have energy savings been measured? 1 Extensive experimental work has identified the energy savings and peak-load reduction benefits of radiant barriers in attics in the southern climates of the U.S. Eight homes, all with air-handling equipment located in the attic, were retrofit with radiant barrier systems in 2000 in central Florida. Subsequent monitoring and data analysis showed cooling energy savings of 9%, peak load reduction of 16%, and an improvement in indoor comfort. i Photos from Reference i, used by permission from the Florida Solar Energy Center, 2001 Previous experimental work in Tennessee on uninhabited homes with no ductwork in the attic also showed significant cooling energy savings. ii Significant savings due to radiant barriers were also measured in controlled laboratory experiments, with and without duct systems in the attic. iii Numerous other studies have established the energy conservation characteristics of a radiant barrier system, with 1 This material is excerpted from a paper presented at the Building Envelope Conference in (Stovall et al, 2010) 16
17 and without the impact of ducts.iv,v,vi,vii,viii As expected, these studies point out the importance of multiple factors in determining the potential energy savings, most importantly: the climate, the presence or absence of ductwork in the attic, and the amount of insulation on the floor of the attic. Photos from Ref viii, showing temperature and heat flux monitor locations in test houses at Fort Irwin, California, 2010 Most of the field tests have been done with clean radiant barriers. Laboratory measurements have shown that dust on the surface of aluminum foil increases the emittance and decreases the reflectivity. This means that dust or other particles on the exposed surface of a radiant barrier will reduce its effectiveness. Radiant barriers installed in locations that collect dust or other surface contaminants will have a decreasing benefit to the homeowner over time. When radiant barriers are newly installed and clean, some testing shows that the attic floor application will work better than the roof applications. How did we estimate the savings shown in this fact sheet?2 It s not possible to test radiant barriers in every city and in every type of house. To understand their performance in other locations, the attic simulator computer program, AtticSim, was developed to calculate the radiative, convective, and conductive energy exchanges in a specific attic geometry, with or without ducts.ix,x This model has been benchmarked against experimental data from controlled laboratory experiments, showing excellent accuracy for attics without ducts and moderate accuracy for attics with ducts.iii, xi, xii The attic model requires that the air temperature below the attic floor and the temperature and timing of air entering the ductwork be specified. To provide these values, a wholebuilding energy model, EnergyPlus, was used. This whole-building model includes leaking attic ducts and radiant energy exchange within the attic, but does not yet include radiant exchange between the attic surfaces and the duct surface.xiii These programs were coupled by using the same physical geometry and materials, the same weather data, and the same rate of duct leakage to calculate the energy lost and gained in the attic for each combination of duct condition, attic insulation level, and radiant barrier use. The building model shown here was used as a base building for this study.xiv The building is a 57 ft 27 ft single-story house with one conditioned zone, an unconditioned attic, and a vented crawl space. 2 This material is adapted from a paper to be presented at the Building Envelope Conference in 2010.(Stovall et al, 2010) 17
18 Figure 1 Schematic of house used in EnergyPlus and AtticSim The analysis was performed for eight cities, representing the eight ASHRAE climate zones. xv For all climate zones, an interior 21 C (70 F) heating set point temperature and 24 C (75 F) cooling set point temperature were used. Two levels of building quality were evaluated, one with adequate ceiling insulation (new), and one with minimal insulation (old). The new homes were taken to have code-level insulation, corresponding to R-30 for climate zones 1 to 3, R-38 for climate zones 4 and 5, and R-50 for climate zones 6 to 8. An attic insulation level of R-19 was used for the older home in all climate zones. The study considered three cases for attic ducts, representing situations with no ducts (and therefore no duct losses), insulated and relatively tight ducts, and uninsulated leaky ducts. To estimate the energy savings attributable to radiant barriers, four values of emittance (ε) for the downward-facing side of the interior attic space and the gable ends were considered; 0.05, 0.1, 0.2, and 0.9. The upward-facing floor of the attic (that is, the top surface of the attic floor insulation) was given an emittance of 0.9. The building thermal load with no radiant barrier (ε = 0.9) was compared with the thermal loads with ε = 0.05, 0.1, and 0.2 to calculate the radiant barrier energy savings. To evaluate the potential economic savings due to radiant barriers, state average fuel prices and representative HVAC system efficiencies were applied to the calculated energy savings. For heat pumps and air conditioners, the seasonal efficiencies required in the 2006 Department of Energy standards were used, a Seasonal Energy Efficiency Ratio of 13 and a Heating Season Performance Factor of 7.7, to translate energy savings to electricity savings. For gas furnaces, an efficiency of 0.85 was assumed. These tables show the energy prices used for each analysis location. For climate zones 1 to 6, all-electric heat pumps were used. For climate zones 7 and 8, gas heat with electric air conditioning was used. 18
19 Energy Prices Taken From EIA 2008 State Average Residential Retail Prices Zone City Electricity ( per kwh) Natural gas ($/1000 ft 3 ) 1 Miami, FL Austin, TX Atlanta, GA Baltimore, MD Chicago, IL Minneapolis, MN Fargo, ND Fairbanks, AK Time-of-Day Prices City Off-Peak price On-peak period On-peak price Miami, FL (FPL, Rate code RS-1) $0.074/kWh Nov.1 to March 31: Monday- Friday 6 AM to 10 AM and 6 PM to 10 PM excluding holidays April 1 through Oct. 31: Monday- Friday 12 Noon to 9 PM excluding holidays $ /kWh Austin, TX (Experimental voluntary residential summer time-of-use rate, 02/17/2010) $0.0456/kWh May 1 to Oct. 31: Monday-Friday 2:00 PM to 8 PM excluding holidays $0.1825/kWh The results of the parametric evaluation showed that the savings estimates are most sensitive to the climate, then the presence and condition of the ductwork, and third the effective emittance of the downward facing surface of the roof sheathing. Analysis shows that the effective emittance of the downward-facing roof surface is very similar for roof sheathing materials with a foil-covered interior surface, and liquid-applied low-emittance coatings. Furthermore, the savings for an emittance ranging from 0.05 to 0.2 were very similar, so consumers are advised that these two approaches, as well as the use of aluminum foil or metalized film-faced materials stapled to the bottom surface of rafters, should provide similar savings. 19
20 Annual savings for a radiant barrier calculated using a coupled Attic-Sim / EnergyPlus model and state average energy prices for a 1,540 ft 2 house. The two values shown for each entry are for radiant barrier emittances of 0.05 and Annual Savings ($ for 1540 ft 2 house) Poor Ducts, R- 19 Poor Ducts, Code Insulation Good Ducts, R19 Good Ducts, Code Insulation No Ducts, R19 No Ducts, Code Insulation Zone When looking at these results, keep in mind that they represent a single, simple, house geometry and that duct conditions in real houses can vary widely and are seldom well characterized. Factors that could make your savings larger than the ones calculated would be: a summer thermostat setting lower than 24 C (75 F), lower efficiency air-conditioner or heat pump, and higher fuel prices. Factors that could make your savings less than the ones calculated would be: a summer thermostat setting higher than 24 C (75 F), light colored roof shingles, shading of the roof by trees or nearby structures, higher efficiency furnace or air-conditioner, and lower fuel prices. References i Parker, D. S., J. R. Sherwin and M. T. Anello, January "FPC Residential Monitoring Project: New Technology Development - Radiant Barrier Pilot Project," Contract Report FSEC-CR , Florida Solar Energy Center, Cocoa, Florida. ii W. P. Levins and M. A. Karnitz, Energy measurements of single-family houses with attics containing radiant barriers, ASHRAE Trans.; Journal Volume 93:2, June 1987 iii Petrie, T. W., K. E. Wilkes, P. W. Childs, and J. E. Christian Effect of Radiant Barriers and Attic Ventilation on Residential Attics and Attic Duct Systems: New Tools for Measuring and Modeling, ASHRAE Trans., vol. 104, iv Parker, D. S. and J. R. Sherwin Comparative Summer Attic Thermal Performance of Six 20
21 Roof Constructions. ASHRAE Trans. 104, Part 2: v Levins, W. P. and Karnitz, M. A. Cooling Energy Measurements of Single-Family Houses with Attics Containing Radiant Barriers in Combination with R-11 and R-30 Insulation, ORNL/CON-226, Oak Ridge National Laboratories, Oak Ridge, TN. vi Parker, D. S., Fairey, P. and Gu, L., "Simulation of the Effects of Duct Leakage and Heat Transfer on Residential Space Cooling Energy Use," Energy and Buildings, #20, Elsevier Sequoia, Netherlands. vii Wilkes, K. E Analysis of Annual Thermal and Moisture Performance of Radiant Barrier Systems, ORNL/CON-319, Oak Ridge National Laboratory, Oak Ridge, TN. viii William (Bill) Miller, Ronnen Levinson, Nigel Cherry, Richard Allen Monier, Hashem Akbari, Phil Childs, Jerry Atchley, Paul Berdahl, TASK FIELD EXPERIMENTS TO EVALUATE COOL- COLORED ROOFING, California Pier Program publication, 2010, ix K. E. Wilkes, Thermal Model of Attic Systems with Radiant Barriers, ORNL/CON-262, Oak Ridge National Laboratory, July 1991 x ASTM C1340, Standard Practice for Estimation of Heat Gain or Loss Through Ceilings Under Attics Containing Radiant Barriers by Use of a Computer Program, Annual Book of ASTM Standards, Vol , Conshohocken, PA, 2009 xi Miller W.A., K.T. Loyle, A.O. Desjarlais, H. Akbari, R. Levenson, P. Berdahl, S. Kriner, S. Weil, and R.G. Scichili Special IR reflective pigments make a dark roof reflect almost like a white roof. Proceedings of ASHRAE Therm IX, the Thermal Performance of the Exterior Envelopes of Buildings IX. December, Clearwater, Florida. xii W. Miller, M. Keyhani, T. Stovall, A. Youngquist, Natural Convection Heat Transfer in Roofs with Above-Sheathing Ventilation, Proceedings of the Thermal Performance of the Exterior Envelopes of Buildings X. December, Clearwater, Florida, ASHRAE, 2007 xiii EnergyPlus, The Board of Trustees of the University of Illinois and The Regents of the University of California through the Ernest Orlando Lawrence Berkeley National Laboratory, U. S. Department of Energy, 2009 xiv NREL/TP a. Home Energy Rating System Building Energy Simulation Test (HERS BESTEST) Volume 1, November 1995 xv Therese Stovall, Som Shrestha, Rao V. Arimilli, David W. Yarbrough, Thomas Pearson, Analysis in Support of the Radiant Barrier Fact Sheet 2010 Update, Proceedings of the Thermal Performance of the Exterior Envelopes of Buildings XI. December, Clearwater, Florida, ASHRAE,
A Prototype Roof Deck Designed to Self-Regulate Deck Temperature and Reduce Heat Transfer
A Prototype Roof Deck Designed to Self-Regulate Deck Temperature and Reduce Heat Transfer William (Bill) Miller, Ph.D. Oak Ridge National Laboratory Oak Ridge, TN, USA Stan Atherton and Russell Graves
Sensitivity of Forced Air Distribution System Efficiency to Climate, Duct Location, Air Leakage and Insulation
LBNL 43371 Sensitivity of Forced Air Distribution System Efficiency to Climate, Duct Location, Air Leakage and Insulation Iain S. Walker Energy Performance of Buildings Group Indoor Environment Department
Preventing Ice Dams on Roofs
Preventing Ice Dams on Roofs Facility Manager November/December 2005 When a roof leaks, facility managers inevitably receive complaints from building occupants. If it is winter, ice dams are often the
PERFORMANCE OF SIDE-BY-SIDE SOUTH TEXAS HOMES Isolating the Contribution of Spray Polyurethane Foam Insulation
PERFORMANCE OF SIDE-BY-SIDE SOUTH TEXAS HOMES Isolating the Contribution of Spray Polyurethane Foam Insulation INTRODUCTION As the use of spray polyurethane foam (SPF) insulation is increasing in both
2014 British Columbia Building Code Changes
District of Houston 250-845-2238 2014 British Columbia Building Code Changes A District of Houston interpretation of the 2014 Building Code Changes for 9.36 & 9.32 The following changes reflect the most
Energy Use in Residential Housing: A Comparison of Insulating Concrete Form and Wood Frame Walls
PCA R&D Serial No. 415 Energy Use in Residential Housing: A Comparison of Insulating Concrete Form and Wood Frame Walls by John Gajda and Martha VanGeem 000 Portland Cement Association KEYWORDS Concrete,
CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN 55110 Fax: 651-429-8503. Re-Roofing: Asphalt Shingles
CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN 55110 Fax: 651-429-8503 Re-Roofing: Asphalt Shingles This is a summary of the standard requirements based on the
Underwriters Laboratories Testing Information
Underwriters Laboratories Testing Information R-8078 Underwriters Laboratories Inc. R-13173 Classified Spray Fiber Surface burning characteristics applied to inorganic reinforced cement board with a maximum
Energy Efficiency. Energy Efficient Home Cooling:
Energy Efficiency Energy Efficient Home Cooling: Choosing an air conditioning system is an important decision. A poor choice may be costly to purchase and operate and yet fail to provide the desired cooling
In the Fall 2002 issue of HHE News I examined
Choosing Replacement Windows 1 For Your Home Mark Pierce In the Fall 2002 issue of HHE News I examined reasons for, and against, replacing older windows with new, energy efficient windows. That article
Contract for Weatherization Management Address City & State
I. Parties Contract for Weatherization Management Address City & State This contract is made and entered into on and specifies the terms of the agreement between Client Name, homeowner, and Sherlock Homes
Molds and mildew are fungi that grow
Appendix C: Moisture, Mold and Mildew Molds and mildew are fungi that grow on the surfaces of objects, within pores, and in deteriorated materials. They can cause discoloration and odor problems, deteriorate
Energy Analysis for Internal and External Window Film Applications for Existing Homes in Florida
Energy & Environmental Solutions Energy Analysis for Internal and External Window Film Applications for Existing Homes in Florida PREPARED FOR: INTERNATIONAL WINDOW FILM ASSOCIATION P.O. BOX 3871 MARTINSVILLE,
air conditioners how to choose a cooling system
air conditioners how to choose a cooling system taking responsibility As an individual, your efficient use of energy brings benefits such as lower bills, improved comfort levels in your home and a reduced
ROOFS, SNOW AND ICE DAMS
ROOFS, SNOW AND ICE DAMS The Problem Ice dams are a common roof performance problem in cold climate buildings. Simply put, they are ridges of ice and icicles caused by melt water from further up the roof
Water Vapor Permeance of Wood Structural Panels and Wood Wall Construction
T e c h n i c a l n o t e Water Vapor Permeance of Wood Structural Panels and Wood Wall Construction Number J450 February 2009 Controlling against moisture damage in structures depends upon proper system
*Trademark of The Dow Chemical Company A business unit of The Dow Chemical Company and its subsidiaries Copyright 2003 The Dow Chemical Company.
Dow Chemical is a Registered Provider with The American Institute of Architects Continuing Education Systems. Credit earned on completion of this program will be reported to CES Records for AIA members.
5 Things. You Must Know. Before Buying. Radiant Barrier
Consumer Report: 5 Things You Must Know Before Buying Radiant Barrier 1 INDEX I: How Do Radiant Barriers Really Work pg 3 A: Understanding Heat Transfer pg 3 B: How Radiant Barriers Stop the Heat pg 4
Before You Start an Energy Efficiency Retrofit The Building Envelope
ABOUT YOUR HOUSE Before You Start an Energy Efficiency Retrofit The Building Envelope The building envelope is the outer layer of the building that separates the indoor living space from the outdoor environment,
Market Potential Study for Water Heater Demand Management
Market Potential Study for Water Heater Demand Management Rebecca Farrell Troutfetter, Frontier Associates LLC, Austin, TX INTRODUCTION Water heating represents between 13 and 17 percent of residential
Facts About Home Cooling
Facts About Home Cooling Energy Savings When keeping cool means air conditioning, keeping comfortable can often be expensive. Especially since air conditioning can add up to over 11% of your bill. But
Air Conditioning. The opportunity for energy efficiency. Low cost actions to reduce energy usage now
Fact Sheet #6 Air Conditioning In this fact sheet you will discover: The opportunity for energy efficiency How air conditioning works Low cost actions to reduce energy usage now Investments to reduce costs
Heating and cooling. Insulation. Quick facts on insulation:
Heating and cooling Heating and cooling your home can be one of the biggest users of energy. Efficency in this area can bring great savings. Heating and cooling depend on many contributing factors. The
Key energy-efficient features of your new home
Key energy-efficient features of your new home Your thermal envelope The thermal envelope, or shell, of your home (walls, roof and floor) is designed to keep you dry and comfortable. It protects you from
Potential of Energy Efficiency and Renewable Energy Savings To Impact Florida s Projected Energy Use in 2014
Potential of Energy Efficiency and Renewable Energy Savings To Impact Florida s Projected Energy Use in 2014 Author Fairey, Philip Publication Number FSEC-RR-58-06 Copyright Copyright Florida Solar Energy
AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries
AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries Hot tips and cool ideas to save energy and money! Air conditioning units or systems are often used by foundries
Ventilation for Cathedral Roofs: How Much Is Sufficient?
Ventilation for Cathedral Roofs: How Much Is Sufficient? Marlea Knox, CDT Metal-Era, Inc. 1600 Airport Rd., Waukesha, WI 53188 Phone: 262-650-6418 Fax: 262-436-4418 E-mail: [email protected] 2 8
Attic condensation during winter can
Housing Fact Sheet Causes and Cures of Attic Condensation and Roof Ice Damming Problems Attic condensation during winter can decrease the effectiveness of insulation and over time can cause significant
The Only GUY To Call. Why are my utility bills so high? What can I do to lower my energy expenses?
The Only GUY To Call May 2014 412.885.2356 Why are my utility bills so high? What can I do to lower my energy expenses? Did you know... that between 2007 and 2012, the average U.S. household spent more
Residential Duct Systems for New and Retrofit Homes
Residential Duct Systems for New and Retrofit Homes Why it is important to properly design and install high quality, efficient ducted air systems? The efficiency of air distribution systems has been found
First Time Home Buyers Energy Efficiency Workshop Guide
First Time Home Buyers Energy Efficiency Workshop Guide Why is efficiency important when buying a home? Affordability: lower utility bills Environmental responsibility: reduces your carbon footprint and
HOW AN ENERGY EFFICIENT HOME CAN HELP THE ENVIRONMENT
HOW AN ENERGY EFFICIENT HOME CAN HELP THE ENVIRONMENT During the last century, concern about the environment increased, as issues such as global warming and the Greenhouse Effect convinced us that the
Presented by: Jennifer Doyle, P.E., RRC, LEED AP
Presented by: Jennifer Doyle, P.E., RRC, LEED AP Moisture Gas: Molecules are spread out "Vapor" suspended in air forms a mixture, present everywhere Liquid: Molecules are closer Rain Condensation Pipes
Residential Windows, 3 rd edition Corrected index 1
Residential Windows, 3 rd edition Corrected index 1 A absorptance definition, 78 determinants of, 78 79 energy performance and, 78 tinted glass, 84 acoustical properties of windows, 60 61 acrylic glazing
keep moisture in check by getting fairly hot and facilitating downward time the sun came out, Then, after installation roof no longer got very
Cool Roofs Cause Condensation Fact or Fiction? by Phil Dregger, PE, RRC, Technical Roof Services, Inc. (Editor s Note: Phil Dregger is a professional engineer, registered roof consultant, author, and fellow
Structure Survey Findings:
Structure Survey Findings: Visible portions of the following were observed: foundations; structure to walls, columns, floors, roofs, overhang posts, and columns; attached or firmly abutting decks, balconies,
LOW-RISE RESIDENTIAL BUILDINGS ADDITIONS AND ALTERATIONS IN EXISTING LOW-RISE RESIDENTIAL BUILDINGS
SUBCHAPTER 9 LOW-RISE RESIDENTIAL BUILDINGS ADDITIONS AND ALTERATIONS IN EXISTING LOW-RISE RESIDENTIAL BUILDINGS SECTION 150.2 ENERGY EFFICIENCY STANDARDS FOR ADDITIONS AND ALTERATIONS IN EXISTING BUILDINGS
research highlight Highly Energy Efficient Building Envelope Retrofits for Houses
research highlight June 2012 Technical Series 12-103 Highly Energy Efficient Building Envelope Retrofits for Houses introduction In Canada approximately 30% of all energy is consumed in buildings, with
Selecting Energy Efficient New Windows in Georgia
Selecting Energy Efficient New Windows in Georgia www.efficientwindows.org January 016 ENERGY STAR Zones 1. Meet the Energy Code & Look for the ENERGY STAR Windows must comply with your local energy code.
ENERGY STAR Certified Homes, Version 3 Cost & Savings Estimates
November 1, 2013 Contents ENERGY STAR Certified Homes, Version 3 Section 1: Executive Summary... 3 Section 2: Detailed Incremental Cost Estimates... 6 Section 3: Incremental Cost & Savings of the Thermal
Residential HVAC System Sizing
Residential HVAC System Sizing William P. Goss University of Massachusetts, Amherst, Massachusetts, USA Corresponding email: [email protected] SUMMARY Heating, ventilating and air-conditioning (HVAC)
Article. Protecting the Building Envelope from Water Damage. MemBrain Smart Vapor Retarder & Air Barrier Film
Article Protecting the Building Envelope from Water Damage Vapor Retarders Play a Crucial Role in Moisture Management Whether we like it or not, moisture in the form of water vapor diffusion and humid
1/9/2013. Terminology Calculating Heat Transfer Code Requirements Design Examples and Sustainability
1/9/13 By Brett T. Fagan, P.E. Presented by Marie Horan, P.E. Building Diagnostics, Inc. Building Diagnostics Terminology Calculating Heat Transfer Code Requirements Design Examples and Sustainability
Home Energy Evaluation Report for Fritz Kreiss and Catherine McQueen
Home Energy Evaluation Report for Fritz Kreiss and Catherine McQueen May 2008 Wisconsin Area PO BOX 115 Lake Geneva, WI 53147 CELL (414) 550-4765 Home Performance with ENERGY STAR Evaluation Report Customer
Sample Customer 123 Conservation Way TAMPA FL 33626 Tracking Number: 000675309
Thank you for completing the Online Home Energy Audit. Based on the answers that you provided in the questionnaire, the following is a complete analysis of your household's energy consumption. We have
ECHO System for Basements
ECHO System for Basements Homeowners looking for more space are all too familiar with the cold, damp and dingy basement. Now, the Enclosure Conditioned Housing (ECHO) System TM, winner of the Ottawa-Carleton
Home inspectors are not mold inspectors, however they do inspect for defects that
CONDENSATION IN THE WALLS Home inspectors are not mold inspectors, however they do inspect for defects that can result in mold. Mold grows in wet or damp environments. Defects that result in a wet or damp
Introduction. 1. Heat Transfer. In Townsville s climate it is essential to choose building materials that perform well in our local conditions.
In Townsville s climate it is essential to choose building materials that perform well in our local conditions. Choosing the correct materials and insulation will improve the overall thermal performance
Uncovering Myths and Opportunities of Advanced Building Envelope Technologies: BIPV, Roofing and Windows
Uncovering Myths and Opportunities of Advanced Building Envelope Technologies: BIPV, Roofing and Windows Marc LaFrance Technology Development Manager US Department of Energy Building Technology Program
Selecting Energy Efficient New Windows in Arizona
Selecting Energy Efficient New Windows in Arizona www.efficientwindows.org January 016 ENERGY STAR Zones 1. Meet the Energy Code & Look for the ENERGY STAR Windows must comply with your local energy code.
APPENDIX C - Florida Energy Code Standard Reference Design Auto-Generation Tests
REM/Rate v15 Review 9/22/14 Purpose This document includes the results of limited testing and verification of the REM/Rate v15.0 software submitted as a simulation tool for demonstrating compliance with
More Bang for Your Buck: Combining Thermal, Air and Water Barrier
More Bang for Your Buck: Combining Thermal, Air and Water Barrier Linda Jeng, Dow Building Solutions 2014 RESNET Atlanta, Jan. 29, 2014 Actual high: 30 F Actual low: 12 F Effect of polar vortex on Atlanta,
Residential Weatherization Plus Program
Since 1982, Cowlitz PUD has been helping its customers reduce their monthly electric bills and make their homes more comfortable through our weatherization programs. Under the current program Residential
High R-Value Does Not Always Mean High Performance
High R-Value Does Not Always Mean High Performance By Charlie Gohman, Building Science and Efficiency Manager, Energy Office, Arizona Department of Commerce Ever since the energy crisis of the 70s we have
Selecting Energy Efficient Replacement Windows in Nevada
Selecting Energy Efficient Replacement Windows in Nevada www.efficientwindows.org January 06 STAR Zones. Meet the Energy Code & Look for the STAR Windows must comply with your local energy code. Windows
Housing Fact Sheets. Energy Saving Window Treatments
Housing Fact Sheets Energy Saving Window Treatments Windows are a major source of heat loss but they are necessary for light, ventilation, and view. In a typical single family home, about 20% of the heat
Reflective Insulation, Radiant Barriers And Radiation Control Coatings
Understanding and Using Reflective Insulation, Radiant Barriers And Radiation Control Coatings Compiled by Second Edition May 2002 Second Edition Copyright May 2002 Reflective Insulation Manufacturers
Modeling and Simulation of HVAC Faulty Operations and Performance Degradation due to Maintenance Issues
LBNL-6129E ERNEST ORLANDO LAWRENCE BERKELEY NATIONAL LABORATORY Modeling and Simulation of HVAC Faulty Operations and Performance Degradation due to Maintenance Issues Liping Wang, Tianzhen Hong Environmental
2009 IECC Update. Scope. Content. International Energy Conservation Code
2009 IECC Update International Energy Conservation Code Scope The code applies to both residential and commercial buildings. In the code, the United States is divided into eight climate zones which are
Green and Energy Efficient Homes What you need to know
Green and Energy Efficient Homes What you need to know Introductions Agenda Why green or energy efficiency? What does it mean for a home to be green or energy efficient? Energy Efficient Construction Techniques
A Study of the Energy-Saving Potential of Metal Roofs Incorporating Dynamic Insulation Systems
A Study of the Energy-Saving Potential of Metal Roofs Incorporating Dynamic Insulation Systems Kaushik Biswas, PhD Associate Member ASHRAE Scott Kriner William Miller, PhD Member ASHRAE Gary Manlove ABSTRACT
ROOF CONDENSATION: A COSTLY PROBLEM
ROOF CONDENSATION: A COSTLY PROBLEM CONTENTS 1. What is it? 2. How does it form? 3. What to look for 4. Repair options 5. Owner responsibilities and proactive measures 1. WHAT IS IT? Roof condensation
How to choose a heat pump and use it wisely
How to choose a heat pump and use it wisely Contents How does a heat pump work? 2 Insulating your home 3 Heat loss in the home Not all heat pumps are created equal 4 Choosing a heat pump 4 Choosing by
Climate and Energy Responsive Housing in Continental Climates. The Suitability of Passive Houses for Iran's Dry and Cold Climate. Farshad Nasrollahi
Climate and Energy Responsive Housing in Continental Climates The Suitability of Passive Houses for Iran's Dry and Cold Climate Farshad Nasrollahi Table of Contents Abstract German Abstract Introduction
CertainTeed. Protecting Your Home From Ice Dams Homeowner s Guide
CertainTeed Protecting Your Home From Ice Dams Homeowner s Guide What Are Ice Dams? Ice dams are formed when heat from the inside of a home escapes into the attic and warms the roof decking during the
RELEASE NOTES EG USA 3.0.0
RELEASE NOTES EG USA 3.0.0 Version 3.0 has a multitude of changes from version 2.8.05. One of the major changes is the ability to break up a home into Blocks with different HVAC systems. This includes
Inspecting to a higher standard.
Inspecting to a higher standard. Rob Hopkin Silver Spring, MD 20902 Monday, June 2, 2014 ProTec Inspection Services Inc. 19736 Selby Ave Poolesville, MD 20837 301-972-8531 www.protec-inspections.com [email protected]
about your house How to Get the Ventilation That You Need in Your House Figure 1 Infiltration and exfiltration of air in a house
about your house CE 64 How to Get the Ventilation That You Need in Your House Canadian houses are relatively airtight, and have been for years. The old farmhouses where people lived several generations
THE IC Y N E N E AD V A N T A G E
THE IC Y N E N E AD V A N T A G E APP L I C A T I O N CA S E ST U D Y : Insulating a Metal Building for Air Sealing/ Energy Efficiency Synopsis: Twice as effective at air sealing versus conventional insulation
EcoTouch Insulation with PureFiber Technology
PROJECT ENGINEER RESPONSIBILITY: This is a general specification guide, intended to be used by experienced construction professionals, in conjunction with good construction practice and professional judgment.
Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit
R-H-DI1 INSULATION BATT NR-E-IB1 Avoid Using Batt Insulation With Metal Framing Batt insulation should not be used with metal framing systems. Although it is common to see fiberglass batt insulation installed
Chapter 8. Duct Design and Sealing
Chapter 8 Duct Design and Sealing Duct Materials The three most common types of duct material used in home construction are metal, rigid fiberglass duct board, and flex-duct. Both metal and fiberglass
TechPractices: Home Front Homes:
TechPractices: Home Front Homes: PATH's Technologies in Practice are large scale housing projects throughout the U.S. where innovative technologies are being installed and used. Information is presented
CERTIFICATE OF COMPLIANCE Prescriptive Residential Re-roof Project Name:
STATE OF CALIFORNIA RESIDENTIAL ALTERATIONS - RE-ROOF CERTIFICATE OF COMPLIANCE Prescriptive Residential Re-roof Project Name: CALIFORNIA ENERGY COMMISSION CF-1R-ALT-01-E (Page 1 of 2) Date Prepared: A.
solutions & tips six Wise Energy Guide Building envelope solutions and simple tips AIR SEALING
Wise Energy Guide solutions & tips 32 AIR SEALING Is your house leaking money? six Building envelope solutions and simple tips If your home is like most, the greatest amount of heat loss is from air leakage;
Measured Energy and Peak Demand Reduction from High Efficiency Air Conditioner Replacement
Measured Energy and Demand Reduction from High Efficiency Air Conditioner Replacement John A. Masiello and Matthew P. Bouchelle, Progress Energy Florida, Inc. Danny S. Parker and John R. Sherwin, Florida
Energy Savings with Window Retrofits
Center for Energy and Environment Energy Savings with Window Retrofits Presentation to Energy Design Conference & Expo Duluth, MN February 25, 2014 Agenda v Background v Introduction: What are window retrofits?
CITY PLAN REVIEW AND INSPECTION. Lisa Fleming Brown, CPM
CITY PLAN REVIEW AND INSPECTION Lisa Fleming Brown, CPM Houston Commercial Energy Conservation Code (2011) A choice of 2009 IECC or ASHRAE 90.1-2007 with amendments. Effective September 2, 2011. Complete
Vented and Sealed Attics in Hot Climates
building science.com 2008 Building Science Press All rights of reproduction in any form reserved. Vented and Sealed Attics in Hot Climates Research Report - 9801 1998 Armin Rudd and Joseph Lstiburek Abstract:
Air-Conditioning Buying Guide
Air-Conditioning Buying Guide Buying a new air-conditioning system is a big decision. This Air-Conditioning Buying Guide can help you make the right choice, save energy and money. Shop with confidence
Your Personal Home Energy Action Plan
www.centralvalleyenergytuneup.org g Your Personal Home Energy Action Plan 123 Sample Street Fresno, Ca 93710 Home Energy Rater Name Company Evaluation Date Joe Rater Rater Services, Inc. 9/1/2013 This
Selecting Energy Efficient New Windows in Florida
Selecting Energy Efficient New Windows in Florida www.efficientwindows.org January 06 Zones. Meet the Energy Code & Look for the Windows must comply with your local energy code. Windows that are certified
Existing Housing Stock
1 How Old and New Houses Use Energy Total Consumption per Household, 2001 120 100 2: RENOVATION - CONCORD, MA million per household 80 60 40 20 Space Heating Electric Air Conditioning Water Heating Refrigerators
CLOSED CRAWLSPACES. Have you ever been in your crawlspace? If not, have you ever even
CLOSED CRAWLSPACES What s In the Crawlspace? Wet Sagging Fiberglass Improper Drainage Have you ever been in your crawlspace? If not, have you ever even opened the door to look inside and see what it looked
24.301.161 INCORPORATION BY REFERENCE OF INTERNATIONAL. (1) The Department of Labor and Industry adopts and incorporates by
24.301.161 INCORPORATION BY REFERENCE OF INTERNATIONAL ENERGY CONSERVATION CODE (1) The Department of Labor and Industry adopts and incorporates by reference the International Code Council's International
Mississippi. Energy and Cost Savings. for New Single and Multifamily Homes: 2009 and 2012 IECC as Compared to the 2006 IECC
BUILDING TECHNOLOGIES PROGRAM Mississippi Energy and Cost Savings for New Single and Multifamily Homes: 2009 and 2012 IECC as Compared to the 2006 IECC 1 2009 AND 2012 IECC AS COMPARED TO THE 2006 IECC
Glossary of Heating, Ventilation and Air Conditioning Terms
Glossary of Heating, Ventilation and Air Conditioning Terms Air Change: Unlike re-circulated air, this is the total air required to completely replace the air in a room or building. Air Conditioner: Equipment
CONDENSATION IN REFRIDGERATED BUILDINGS
CONDENSATION IN REFRIDGERATED BUILDINGS By: Steve Salisbury Nov. 10, 2010 (revised Nov. 14, 2013) Introduction The following discussion reviews the basic causes of condensation in refrigerated buildings
6 Ceiling fans! Although they only use about as. 8 Redecorate. Hang lighter colored curtains
Shut all exterior doors and windows tightly when the air conditioning is on. Maximize 1 your savings by switching off kitchen and 9 bath exhaust fans. Keep an eye on your AC filters. Change or 2 10 clean
COMMERCIAL BUILDING APPLICATIONS
EXPANDED POLYSTYRENE FOR COMMERCIAL BUILDING APPLICATIONS www.falconfoam.com Commercial Building Ap Expanded Polystyrene Insulation Falcon Foam leads the commercial building industry with products that
Retrofit EnerLogic Low-e Window Films
Retrofit EnerLogic Low-e Window Films Steve DeBusk Global Architectural Technical Services Manager May 18, 2015 ORNL Envelope Stakeholder Workshop Eastman Overview Eastman Global specialty chemical company.