FYI > California Title 24
|
|
- Austin Brooks
- 8 years ago
- Views:
Transcription
1 FYI > California Title 24 Rinnai America Corporation ("RAC") prepared the below summary of California Title 24, primarily based on the California Energy Commission s 2013 Building Energy Efficiency Standards. The purpose of this document is to provide a general overview of the requirements of California Code of Regulations (CCR) Title 24. This document is offered for informational purposes only as a broad summary of information provided by California Energy Commission; it is not a legal document. What is Title 24? Title 24 references numerous state regulations that govern the design and construction of buildings and facilities as well as energy conservation. Within Title 24, there are multiple sections, each of which reference specific requirements concerning the codes for Electrical, Mechanical, Plumbing, etc. To ensure proper compliance, you should refer directly to CEC Title 24 or contact a professional certified in this area. Title 24 Compliance Title 24 breaks down energy use in buildings into several categories: space heating, space cooling, water heating and lighting. Since usage is impacted by climate conditions in the different areas of the State, the calculations will vary by Zone. The 16 Zones are shown in the below map provided by T24-Reports.com. Title 24 provides two methods for compliance: (1) Prescriptive Method: Each individual component of the proposed building must meet a prescribed minimum energy requirement. Certain requirements define maximum levels, such as maximum number of windows allowed. While it is the simplest approach, it is also the least flexible for compliance and is typically only used in 5-10% of the applications. (2) Performance Method: Also known as the computer method, requires a detailed total accounting of a building s energy usage. The budget for the proposed house is compared to a standard that not only considers the type of energy that is used (electricity, gas, or propane), but also when it is used. Unlike the Prescriptive Method, the overall valuation can then be manipulated with trade-offs, upgrades or downgrades of conservation features. While this approach requires the most effort, it also provides the greatest flexibility and as such is typically used in 90-95% of the applications.
2 HERS, RESNET and Title 24 To achieve compliance with the Title 24 Standards, some buildings require diagnostic testing or field verification of energy efficient systems or devices by a HERS (Home Energy Rating System) to determine compliance. HERS is a nationally recognized index developed by the Residential Energy Services Network (RESNET) and reflects a home's energy efficiency similar to the standards that are employed by the California s Title 24. Water Heating Equipment and Distribution Systems Within the CCR Plumbing Code, there are minimum standards for water heating equipment and hot water distribution systems. The water heating budget is based on minimum energy factors that appear in the CCR 2013 Residential Compliance Manual, Table 5.1 at right. The use of tankless water heaters provides an opportunity for potential energy savings. The chart below right, provided by Title 24, Inc., reflects estimated percent savings of a tankless water heater over a standard 50 gallon gas fired water heater. The energy impact of the hot water distribution system is also a key component of the overall system calculations and can vary widely based on the type of system, type of configuration, quality of installation and house design. Hot water distribution systems are broken down into two main categories based on application: 1) One or more water heating systems serving a single dwelling unit (includes single family homes and dedicated water heating systems serving a single dwelling unit in multifamily and hotel/motel buildings) 2) Multi-family central distribution systems (One or more central water heaters serving multiple dwelling units). Percentage of Improvement over Standard 50 Gallon Gas-fired Water Heater with.62 EF Climate Zone 6 Los Angeles & Orange County Coastal Climate Zone 7 San Diego Coastal Climate Zone 8 Orange County Inland Climate Zone 9 Los Angeles County Inland Climate Zone 10 San Bernardino & Riverside Counties Climate Zone 14 High Desert Climate Zone 15 Low Desert Non-Condensing Tankless Condensing Tankless (.82 EF) (.94 EF) 10.20% 16.00% 9.50% 14.70% 7.30% 11.30% 6.40% 3.30% 9.80% 4.90% 7.50% 5.20% 3.10% 4.50%
3 There are many types of configurations that may be used. The impact on the overall calculations of various methods is reflected in CCR 2013 Residential Compliance Manual, Table 5-7 at right. The incorporation of recirculation into the overall water heating distribution system design has become more popular due to its water conservation potential, but it comes at a cost to the overall Title 24 energy compliance. There are many different options available. However, all have a multiplier greater than 1.0 due to the fact that the Title 24 Standard is based on a system without recirculation. The code defines the different recirculation systems as follows: Recirculation w/non-demand controls (R-ND) This option includes all recirculation controls with the exception of demand recirculation control systems. The active control shall be either: timer, temperature, or time and temperature. Timers shall be set to less than 24 hours. The temperature sensor shall be connected to the piping and to the controls for the pump. This method has the largest multiplier as it assumes worst case which would be the pump running nearly 24-hours continuous. Demand Recirculation; Sensor Control (R-DAuto) Demand controlled recirculation systems shall operate on-demand, meaning that pump operation shall be initiated shortly prior to the hot water draw. The controls shall operate on the principal of shutting off the pump with a sensed rise in pipe temperature (Delta-T). For this measure, a sensor control is used to activate the pump rather than a manual control. Better than R-ND, but still can operate beyond actual use; therefore, it has negative impact on overall Title 24 compliance. Demand Recirculation; Manual Control (R-Dman) Demand controlled recirculation systems shall operate on-demand, meaning that pump operation shall be initiated shortly prior to the hot water draw. The controls shall operate on the principal of shutting off the pump with a sensed rise in pipe temperature (Delta-T). A manual switch is used to activate the pump. While better than other methods mentioned above, since the Standard (as shown on Table 5-7) is a system with no recirculation at all, R-Dman has a negative impact on the overall Title 24 compliance Title 24 Highlights and the Impact on Different Systems One or more water heating systems serving a single dwelling unit: New Mandatory Requirements for New Construction include: a) A 120V receptacle that is within 3 feet of the water heater and accessible to the water heater with no obstructions. b) A condensate drain that is no more than 2 inches higher than the base of the installed water heater, and allows natural draining without pump assistance. c) A gas supply line with a capacity to provide at least 200,000 Btu/hr to the water heater.
4 d) Pipe insulation is a mandatory requirement in the following cases: 1. The first 5 feet of hot and cold water pipes from the storage tank or water heater. 2. All piping with a nominal diameter of ¾ or larger. 3. All piping within a domestic hot water recirculation system regardless of the pipe diameter. This excludes branches off of the recirculation loop that are less than ¾ diameter or do not serve the kitchen. 4. Piping from the heating source to a storage tank or between tanks. 5. All hot water pipes from the heating source to the kitchen fixtures. With the exception of item d, all of the above measures are designed to make the dwelling unit High Efficiency Ready for upgrades to the hot water system. It is significantly more cost effective to install these items at time of initial construction. Addition of new mandatory pipe insulation requirements is seen as an opportunity to minimize heat loss in the distribution system. New Prescriptive Requirements: With the changes in the 2013 standards, in a single family residence when using the prescriptive method, for a system with a single gas or propane instantaneous water heater without a storage tank one must have: a) A gas input rating < 200,000 Btu/h, no supplemental storage tank is installed b) Use a trunk and branch distribution system with all pipes from the water heater to the kitchen being insulated and all pipe with a diameter equal to or greater than ¾ be insulated. c) No recirculation systems installed. New Performance Compliance Options include: a) Point of Use Distribution multiplier now applies to systems with water heaters no more than (5 of ¾ ), (10 of ½ ), or (15 of 3/8 ) of pipe from any point of use are acceptable alternatives. Distances are measured in plan view, allowing for water heaters on either the first or second floor to serve points located on the floor above or below, hence ignoring the direct vertical length of pipe from the water heater. This measure requires HERS verification. b) HERS verified Compact Distribution System credit has been added as a new compliance option credit. The furthest hot water use point from the water heater must be field measured and shown to be within a prescribed distance from the water heater. This measure requires HERS verification. c) Optional HERS verification elements have been added to offer credits for verified quality pipe insulation installation on both recirculating and non-recirculating distribution systems. This measure requires HERS verification. d) Central home run manifold systems located within 5 feet of the water heater will receive a small compliance credit. This measure requires HERS verification. These are intended to give compliance credit for well-designed distribution systems that minimize potential energy losses. Such things as pipe insulation and more efficient distribution design are clearly seen the best options for making a positive impact on the overall Title 24 energy compliance. Multi-family central distribution systems: New Mandatory Requirements: a) Dwelling unit Pipe insulation is now required on all hot water distribution piping greater than ¾ inch diameter, as well as all piping from the water heater to the kitchen. In central multi-family systems all piping in the recirculation loop must be insulated. This requirement applies to the distribution for each dwelling unit. The pipe from the central distribution system to the kitchen or any pipe ¾ inch or greater in the unit distribution system must be insulated. Minimizing energy losses in distribution systems appears to be a main focus in 2013.
5 New Prescriptive Requirements: a) Demand recirculation controls are basis of performance energy budget for buildings w/ central recirculation systems. b) Water heating recirculation systems are required to be designed w/ two recirculation loops. This measure must be HERS verified to ensure that two sets of recirculation loops are put in place from either the same or separate water heating equipment. Again, these appear to stress the need for well-designed distribution systems that minimize potential energy losses. These new prescriptive rules were added based on studies that found that recirculation pipe heat loss is a major component of energy loss within a central hot water system. New Performance Compliance Options: For systems serving multiple dwelling units with a recirculating pump, the standard distribution system design is based on a central recirculation system with two recirculation loops which are controlled by a demand control technology. Systems designed with other options are allowed but they require compliance verification through performance calculation. More details can be found in the 2013 Residential Compliance Manual, January 2013 edition, Section While demand recirculation controls are the basis of the performance energy budget, both temperature modulation controls and time clock controls can be used for performance compliance. Using temperature modulation controls will require additional energy efficiency measures to offset higher energy consumption due to higher recirculation loop pipe heat loss than those for demand controls. Using time clock controls will require even more efficiency measures to offset relatively high heat losses from recirculation loops using this control strategy. Continuing on the theme of minimizing potential energy losses. (More details can be found in the 2013 Residential Compliance Manual, January 2014 edition, Section 5.1.2) 2013 Title 24 Rinnai Perspective The use of Rinnai Tankless Water Heaters is a great option to meet the overall Title 24 energy compliance needs. Below is an example (extracted from Designing For Compliance (9/29/11), of how using a Rinnai tankless water heater can assist in achieving the efficiency required by Title 24 when both the space heating and cooling equipment have a negative effect on the calculation. Applying the Title 24 Standards using a.62 EF, our Luxury Series, Non-Condensing RL75 with a.82 EF reflects a 33.9% improvement. The use of this Rinnai tankless water heater gives the overall proposed design an all-important improvement of.4% in the energy usage calculations. For those looking to utilize a recirculation system in their proposed design, the most energy-efficient method is the Demand Recirculation; Manual Control (R-Dman) with only a 1.15 multiplier. The key feature to this on-demand method is the use of a manual switch to activate the recirculation pump. Rinnai Tankless Water Heaters have been used effectively for years with this type of system. Other viable options, like Rinnai s Circ-Logic, which is timer-based, are considered Recirculation; Non-Demand Control (R-ND).
6 Since ANY type of recirculation is seen as having a negative energy impact, a better question might be How can I achieve less water loss in my hot water distribution system and thereby eliminate the need for recirculation? Potential design solutions may be in Table 5-7 below from the CCR 2013 Residential Compliance Manual. Compact Design (CHWDS-H) which garners a potential 30% savings (.7 multiplier) or better Pipe Insulation (PIC-H) with a 20% potential savings (.8 multiplier), cannot only have a major impact on Title 24 calculations, but may also eliminate the need for recirculation totally. The versatility of a tankless water heater which, allows one to easily locate closer to fixtures, is ideally suited for Compact Design, saving you additional project cost on equipment, materials and labor. The installation of a tankless water heater is the best decision when thinking of the overall implications of Title 24 on the construction and energy usage in buildings, along with the new requirements that mandate the builder to implement measures to make the dwelling unit High Efficiency Ready. We hope energy conversation AND water conservation are at the top of everyone s list when designing, specifying and installing hot water distribution systems and equipment, and Rinnai has current solutions that support both these important initiatives.
Cost Estimation for Materials and Installation of Hot Water Piping Insulation
Cost Estimation for Materials and Installation of Hot Water Piping Insulation Prepared for Pacific Northwest National Laboratory Under Contract Number: 18O9O2 By Gary Klein, Managing Partner Affiliated
More informationSaving Water and Energy in Residential Hot Water Distribution Systems. Gary Klein California Energy Commission
Saving Water and Energy in Residential Hot Water Distribution Systems Gary Klein California Energy Commission What Do You Want from your Hot Water System? Safety Not too hot Not too cold No harmful bacteria
More informationCase Studies in Restaurant Water Heating
Case Studies in Restaurant Water Heating Donald Fisher, Fisher-Nickel, Inc. William Pietrucha, Pacific Gas and Electric Company ABSTRACT This paper presents an overview of hot water use and the associated
More informationHigh Performance Hot Water Systems Denver July 2010
High Performance Hot Water Systems Denver July 2010 Gary Klein Affiliated International Management, LLC 916-549-7080 gary@aim4sustainability.com Gary Klein, 2010 Gaps Hot water is a system We need systemic
More informationCHAPTER 9: WATER HEATING
Chapter 9: Water Heating 145 CHAPTER 9: WATER HEATING Energy costs for water heating can be as great as the costs for heating, for an energy efficient house, in a mild climate. Estimating hot water usage
More informationSECTION 22000. Hot Water Heaters (Hot Water Recirculation Systems and Point-of-Use Water Heaters)
SECTION 22000 Hot Water Heaters (Hot Water Recirculation Systems and Point-of-Use Water Heaters) PART I - GENERAL A. Description This section includes requirements for materials for installation of Hot
More informationGuide for Efficient Hot Water Delivery Systems
s 1.0 Introduction This guide is designed to help builders better understand and meet the hot water delivery system criteria as specified in the WaterSense New Home Specification (WaterSense new home specification).
More informationTANKLESS WATER HEATER INSTALLATION DIAGRAMS
TANKLESS WATER HEATER INSTALLATION DIAGRAMS Installation Diagrams Tankless Installation / Optional Return Small 10-15 Gallon Point-of-Use Water Single and Optional Return : One single, small capacity water
More informationEvaluation of Potential Best Management Practices - Tankless Water Heaters
Evaluation of Potential Best Management Practices - Tankless Water Heaters Prepared for The California Urban Water Conservation Council 716 Tenth Street, Suite 200 Sacramento, CA 95814 (916) 552-5885 September
More informationCodes and High Performance Hot Water Systems. Gary Klein Affiliated International Management, LLC 916 549 7080 gary@aim4sustainability.
Codes and High Performance Hot Water Systems Gary Klein Affiliated International Management, LLC 916 549 7080 gary@aim4sustainability.com Annual Energy Use for Heating Water Natural Gas Gallons Per Day
More informationIn Part 1 of this article (see January/February 2005
Hot-Water Distribution Systems Part II By Gary Klein This article was first published in P l u m b i n g Systems & Design magazine by the American Society of Plumbing Engineers. It is reprinted with updated
More informationCalifornia Solar Initiative (CSI) Thermal Program Metering Installation Guide
California Solar Initiative (CSI) Thermal Program Metering Installation Guide Purpose: The purpose of this metering installation guide is to provide participating eligible contractors in the CSI-Thermal
More informationEnergy Efficiency Business Rebates Natural Gas Catalog
Energy Efficiency Business Rebates Natural Gas Catalog RECENT NATURAL GAS CHANGES A new table has been added to the process boiler section. Please review to ensure your product meets all efficiency requirements.
More informationIncorporation of Hot Water Demand Reduction into HERS 2013 RESNET Building Performance Conference
Copyright 2013, Gary Klein, Affiliated Interna:onal Management, LLC Incorporation of Hot Water Demand Reduction into HERS 2013 RESNET Building Performance Conference Gary Klein Affiliated Interna:onal
More informationStandards Will Be Here Before You Know It!
THE GAME The New Water Heater Efficiency s and How They Impact Your Business CHANGER September 2014 READY New Water Heater Efficiency s Will Be Here Before You Know It! On April 16, 2015, there will be
More informationSynergy of demand water heaters with solar and radiant floor heating
Synergy of demand water heaters with solar and radiant floor heating... butter with a chain saw Heating water with electricity is like cutting -Amory Lovins Everybody likes a hot shower, but that doesn
More informationLOW-RISE RESIDENTIAL BUILDINGS ADDITIONS AND ALTERATIONS IN EXISTING LOW-RISE RESIDENTIAL BUILDINGS
SUBCHAPTER 9 LOW-RISE RESIDENTIAL BUILDINGS ADDITIONS AND ALTERATIONS IN EXISTING LOW-RISE RESIDENTIAL BUILDINGS SECTION 150.2 ENERGY EFFICIENCY STANDARDS FOR ADDITIONS AND ALTERATIONS IN EXISTING BUILDINGS
More informationDomestic Hot Water Systems and Plumbing Products
Domestic Hot Systems and Plumbing Products Taco Catalog #100-117 Effective Date: 09/02/15 Supersedes: 06/22/15 Printed in USA Domestic Hot Recirculation Taco Domestic Hot Plumbing Products Since 1920 Taco
More informationPLBG/GAS SAFETY Information Bulletin
PLBG/GAS SAFETY Information Bulletin November 2012 P/G-08-02-PLBG/GAS [Rev 3] Page 1 of 11 SUBJECT: REQUIREMENTS FOR COMBINATION HEATING SYSTEMS: DUAL PURPOSE WATER (POTABLE) HEATER (COMBO UNIT) Safety
More informationresearch highlight Monitoring Performance of Retrofitting from Tank to Tankless Water Heaters
research highlight December 2011 Technical Series - 11-101 Monitoring Performance of Retrofitting from Tank to Tankless Water Heaters Background Domestic hot water energy consumption represents the second
More information2010 Residential Water Heater Replacement Check List
2010 Residential Water Heater Replacement Check List The intent of this check list is to provide installers a general reference for the enforcement of code requirements in the Greater San Diego Area. This
More informationEnergy Efficiency. Energy Efficient Water Heating: Purchasing a new electric water heater. Hot water use has a significant impact on your bill.
Energy Efficiency Energy Efficient Water Heating: Purchasing a new electric water heater. Water heating accounts for about 18 percent of your home energy bill. Only space heating and cooling account for
More informationTankless Water Heater A Primer for Contractors, Installers, Builders and Homeowners
Tankless Water Heater A Primer for Contractors, Installers, Builders and Homeowners Your Questions Answered Common applications Benefits of performance How to select, size and install Efficient water heating
More informationASPE Seminar Water Heater Piping Strategies. Presented by Joe Kalarickal, EIT Regional Sales Manager AERCO International
ASPE Seminar Water Heater Piping Strategies Presented by Joe Kalarickal, EIT Regional Sales Manager AERCO International Presentation Overview Water Heater Piping Strategies How to size a water heater?
More informationIndirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS
Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS Contents Page Ratings and Specifications..................... 2 Installation Requirements......................
More informationCONDENSING TANKLESS WATER HEATERS
Ty Tipton, Tipton Company Brian Fenske, Navien America CONDENSING TANKLESS WATER HEATERS THE BASICS OF TANKLESS WATER HEATERS Tankless water heaters are available in Electric Natural gas Propane fired
More informationResidential/Commercial Gas Condensing High Efficiency Tankless Water Heaters
Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters FEATURES ULTRA-LOW NOx CONDENSING TECHNOLOGY PROVIDES UNPRECEDENTED 0.95 ENERGY FACTOR DURABLE HEAT EXCHANGER Primary Heat Exchanger
More informationCondensing Boilers. High Efficiency. Proven Reliability, American-Made Home Heating Comfort. ANYWHERE UNMATCHED
High Efficiency Condensing Boilers Proven Reliability, American-Made Home Heating Comfort. Look for this logo throughout this literature to see the unique features that set U.S. Boiler Company apart from
More informationMultifamily Central Heat Pump Water Heating
Multifamily Central Heat Pump Water Heating Elizabeth Weitzel Davis Energy Group Alliance for Residential Building Innovation (ARBI) January, 2015 The work presented in this presentation does not represent
More informationMeasure Guideline: Transitioning to a Tankless Water Heater
Measure Guideline: Transitioning to a Tankless Water Heater K. Brozyna and A. Rapport IBACOS, Inc. September 2012 NOTICE This report was prepared as an account of work sponsored by an agency of the United
More informationWater Heating and Heat Recovery 1
PID 113 (488) Water Heating and Heat Recovery 1 Florida Power Corporation 2 ENERGY-EFFICIENT WATER HEATING: IT S THE EASIEST WAY TO SAVE ENERGY DOLLARS Anywhere from 10% to 25% of the money you spend on
More informationCodes and Standards Research Report. California s Residential Indoor Water Use. 2 nd Edition (Revised May 8, 2015)
Codes and Standards Research Report California s Residential Indoor Water Use 2 nd Edition (Revised May 8, 2015) Codes and Standards Research Report California s Residential Indoor Water Use 2 nd Edition
More informationDomestic Hot Water Recirculation Systems Application, Selection & Installation Guide
Water Circulation Pumps & Circulators Domestic Hot Water Recirculation Systems Application, Selection & Installation Guide Taco Catalog # 100-41 Supersedes: 08/07/15 Effective Date: 09/01/15 Printed in
More informationIdaho Energy and Cost Savings
BUILDING TECHNOLOGIES PROGRAM Idaho Energy and Cost Savings for New Single and Multifamily Homes: 2012 IECC as Compared to the 2009 IECC 1 2012 IECC AS COMPARED TO THE 2009 IECC Idaho Energy and Cost Savings
More informationCODE NOTES. Insulation Requirements in Commercial Buildings for Mechanical and Service Hot-Water Piping
BUILDING TECHNOLOGIES PROGRAM Insulation Requirements in Commercial Buildings for Mechanical and Service Hot-Water Piping The intent of the pipe insulation requirements is to reduce temperature changes
More informationCodes and Standards Research Report. California s Residential Indoor Water Use
Codes and Standards Research Report California s Residential Indoor Water Use Codes and Standards Research Report California s Residential Indoor Water Use FUNDED THROUGH A GRANT FROM: 1215 K Street, Ste.
More informationOregon Administrative Rules, Chapter 918-2016 Compilation- Building Codes Division DIVISION 695
DIVISION 695 Hist.: DC 2-1983, f. & ef. 1-3-83; Renumbered from 814-020- PLUMBING LICENSING AND CERTIFICATION 0040; BCD 6-1998, f. 3-2-98, cert. ef. 4-1-98, Renumbered from 918-690-0055; BCD 21-1998, f.
More informationWater Heaters. Condensing Storage. In my 30-plus years as a plumbing contractor,
Condensing Storage Water Heaters These heaters are up to 96 percent efficient and typically easier to retrofit than tankless models by Jim Lunt In my 30-plus years as a plumbing contractor, I ve replaced
More informationPlumbing Supply Piping Planning Tool Reducing Water Wasted Waiting for Hot
Plumbing Supply Piping Planning Tool Reducing Water Wasted Waiting for Hot Craig Selover Selover Consulting craig@dotmc.us H:248 542-3010 C:248 917-1380 Floor Plan Floor Plan All Piping WaterSense,HERS,
More informationThe efficient heat pump
The efficient heat pump KCP&L has worked hard to build one of the best reliability records in the industry and we want to help you make the most of the energy we provide. That s why we offer information
More informationENERGY EFFICIENCY COMPARISON
California Energy Commission STAFF REPORT ENERGY EFFICIENCY COMPARISON California s Building Energy Efficiency Standards and the International Energy Conservation Code and American Society of Heating,
More informationSTATE SUPER HIGH EFFICIENCY Up To 96% Thermal RESIDENTIAL PREMIER POWER-VENT MODELS
STATE SUPER HIGH EFFICIENCY Up To 96% Thermal GAS WATER HEATERS Efficiency RESIDENTIAL PREMIER POWER-VENT MODELS PREMIER POWER-VENT DV RESIDENTIAL GAS WATER HEATER The ideal choice for high-demand homes
More informationRELEASE NOTES EG USA 3.0.0
RELEASE NOTES EG USA 3.0.0 Version 3.0 has a multitude of changes from version 2.8.05. One of the major changes is the ability to break up a home into Blocks with different HVAC systems. This includes
More informationTankless water heaters
imagine RHEEM TANKLESS WATER HEATERS never running out of hot water again Tankless water heaters Continuous hot water continuoushot water from Rheem 1-2 RTG-64 Series RTG-64DV, RTG-64X Natural or LP Gas.
More informationSelecting a New Water Heater
U ENERGY EFFICIENCY AND RENEWABLE ENERGY CLEARINGHOUSE Selecting a New Water Heater Many homeowners wait until their heater fails before shopping for a replacement. Because they are in a hurry to regain
More informationHot Water Heating: Technologies and Use
Hot Water Heating: Technologies and Use Skip Hayden Integrated Energy Systems CanmetENERGY Better Buildings by Design 2010 Burlington Vermont February 2010 Natural Resources Canada Ressources naturelles
More informationHeating Load HERS: Calcs Duct Seal and Test. 150.0(h), 150.0 (m)1-3 & 11
Split Systems and Packaged Systems Change this (and nothing else) Whole split or packaged system (no ducts added or replaced) Evaporator coil (cooling coil), condenser coil, or outdoor condensing unit
More informationBUILDING CODE MANUAL COUNTY OF LOS ANGELES DEPARTMENT OF PUBLIC WORKS BUILDING AND SAFETY DIVISION Based on the 2014 LACBC
BUILDING CODE MANUAL COUNTY OF LOS ANGELES DEPARTMENT OF PUBLIC WORKS BUILDING AND SAFETY DIVISION Based on the 2014 LACBC #145 106.4 Article 3 04-01-14 Page 1 of 7 PLUMBING FIXTURE REPLACEMENT ISSUE:
More informationDRAFT ONLY ORDINANCE NO.
ORDINANCE NO. An ordinance amending certain provisions of Articles 4 and 9 of Chapter IX of the Los Angeles Municipal Code to establish citywide water efficiency standards and require water-saving systems
More informationHeating Oil Conservation and Fuel Switching
Heating Oil Conservation and Fuel Switching Summary: Demand Side Management for Heating Oil Demand side management (DSM) is the modification of consumer demand for energy through various methods such as
More informationWhat s the Big Deal About Tankless Water Heaters? A WHITE PAPER
What s the Big Deal About Tankless Water Heaters? A WHITE PAPER Dr. William R.Hoover A.O.Smith Corporate Technology Center As energy supplies tighten and fuel costs increase, tankless water heaters are
More informationTennessee. Energy and Cost Savings. for New Single and Multifamily Homes: 2009 and 2012 IECC as Compared to the 2006 IECC
BUILDING TECHNOLOGIES PROGRAM Tennessee Energy and Cost Savings for New Single and Multifamily Homes: 2009 and 2012 IECC as Compared to the 2006 IECC 1 2009 AND 2012 IECC AS COMPARED TO THE 2006 IECC Tennessee
More informationCommissioning - Construction Documents (Page 1 of 6)
Commissioning - Construction Documents (Page 1 of 6) A. General Information Climate Zone: Building Type: Conditioned Area (sf): Reviewer's Name: Reviewer's Agency: Note: Design Review for each system/subsystem
More informationC I T Y O F S E L M A F I R E D E P A R T M E N T
C I T Y O F S E L M A F I R E D E P A R T M E N T Informational Bulletin Regarding Residential Fire Sprinkler Systems for One and Two Family Homes: Frequently Asked Questions ADMINISTRATIVE PROVISIONS:
More informationEnergy Analysis for Window Films Applications in New and Existing Homes and Offices
Energy & Environmental Solutions Energy Analysis for Window Films Applications in New and Existing Homes and Offices PREPARED FOR: INTERNATIONAL WINDOW FILM ASSOCIATION P.O. BOX 3871 MARTINSVILLE, VA 24115-3871
More informationTANKLESS DURABILITY Tankless Product Guide
TANKLESS DURABILITY Tankless Product Guide Energy-efficient, plentiful, and endless supply of hot water. Compact size and wall-mounted to free up valuable floor space. SAVE ENERGY. SAVE SPACE. PAGE [ 2
More informationSIZING AND CAPACITIES OF GAS PIPING
CALIFORNIA RESIDENTIAL CODE MATRIX ADOPTION TABLE APPENDIX A SIZING AND CAPACITIES OF GAS PIPING (Matrix Adoption Tables are non-regulatory, intended only as an aid to the user. See Chapter 1 for state
More informationThe District Energy Manager and Classroom Heating
Mt. Carmel Area School District Energy Conservation Policy Adopted 6/19/06 These guidelines supersede all previous instructions. It is crucial that these energy guidelines be observed in the operation
More informationHome comfort: water heating
Home comfort: water heating Water heating usage Hot water. It s one of those luxuries we give little thought to until we run out. This information is provided to help you get the most value and comfort
More informationNAVIEN AMERICA INC. 17855 FITCH AVENUE
Navien America Inc. Specification Details for the Navien models: CC-240 CC-240A For Potable Water Heating and Space Heating NAVIEN AMERICA INC. 17855 FITCH AVENUE IRVINE, CALIFORNIA, USA 92614 Toll Free:
More informationTHERM Tankless Water Heaters. Applications Manual
THERM Tankless Water Heaters Applications Manual 2 THERM Tankless Water Heater Applications Manual THERM Tankless Water Heater Applications Manual 3 Table of Contents 1 Introduction 4 2 Bosch THERM Model
More informationIndiana Energy and Cost Savings
BUILDING TECHNOLOGIES PROGRAM Indiana Energy and Cost Savings for New Single and Multifamily Homes: 2012 IECC as Compared to the 2009 IECC 1 2012 IECC AS COMPARED TO THE 2009 IECC Indiana Energy and Cost
More informationThe formula for finding CFM is: CFM = BTUH OUTPUT_ Temp Rise (ACF)* *Altitude correction factor below 1000ft = 1.08
Air Volume Requirement Air conditioning systems are engineered with a specific amount of indoor air passing across the surface of the evaporator coil. The amount of air is measured in cubic feet per minute.
More informationEnergy and Cost Savings
BUILDING TECHNOLOGIES PROGRAM Rhode Island Energy and Cost Savings for New Single- and Multifamily Homes: 2012 IECC as Compared to the 2009 IECC 1 2012 IECC AS COMPARED TO THE 2009 IECC Rhode Island Energy
More informationThis report presents the findings and recommendations of the assessment of energy use and
This report presents the findings and recommendations of the assessment of energy use and environmental stewardship of Arlington Street Church, Boston, MA. As stewards of the earth it is important that
More informationNorth Carolina Heating and Cooling Equipment Incentive Application
North Carolina Heating and Cooling Incentive Application Questions? Call 1-866-380-9580 or visit www.duke-energy.com Email the complete, signed application with all required documents to PrescriptiveIncentives@duke-energy.com
More informationGeorgia Energy and Cost Savings
BUILDING TECHNOLOGIES PROGRAM Georgia Energy and Cost Savings for New Single and Multifamily Homes: 2012 IECC as Compared to the 2009 Georgia Energy Code 1 2012 IECC AS COMPARED TO THE 2009 GEORGIA ENERGY
More informationenergy-saving checklist a guide for rental property owners
energy-saving checklist a guide for rental property owners taking responsibility As an individual, your efficient use of energy brings benefits such as lower bills, improved comfort levels in your home
More informationColorado Energy and Cost Savings
BUILDING TECHNOLOGIES PROGRAM Colorado Energy and Cost Savings for New Single and Multifamily Homes: 2009 and 2012 IECC as Compared to the 2006 IECC 1 2009 AND 2012 IECC AS COMPARED TO THE 2006 IECC Colorado
More information2013 BUILDING ENERGY EFFICIENCY STANDARDS
2013 BUILDING ENERGY EFFICIENCY STANDARDS Title 24, Part 6, and Associated Administrative Regulations in Part 1 CALIFORNIA ENERGY COMMISSION Edmund G. Brown Jr., Governor MAY 2012 CEC 400 2012 004 CMF
More informationUNDERSTANDING CENTRAL HEATING SYSTEMS
UNDERSTANDING CENTRAL HEATING SYSTEMS This advice guide is part of a series of free guides produced by the Association of Plumbing & Heating Contractors Ltd. which provide consumers with essential basic
More informationA COMPARISON OF WATER LEAK DETECTION AND SHUTOFF SYSTEMS
A COMPARISON OF WATER LEAK DETECTION AND SHUTOFF SYSTEMS By Charles Ergle January 16, 2012 As every appraiser knows, water damage is the single highest continual source of claims at Chubb. Fires happen,
More informationMississippi. Energy and Cost Savings. for New Single and Multifamily Homes: 2009 and 2012 IECC as Compared to the 2006 IECC
BUILDING TECHNOLOGIES PROGRAM Mississippi Energy and Cost Savings for New Single and Multifamily Homes: 2009 and 2012 IECC as Compared to the 2006 IECC 1 2009 AND 2012 IECC AS COMPARED TO THE 2006 IECC
More informationSession 2: Hot Water Supply
MEBS6000 Utility Services http://www.hku.hk/mech/msc-courses/mebs6000/index.html Session 2: Hot Water Supply Dr. Benjamin P.L. Ho Department of Mechanical Engineering The University of Hong Kong E-mail:
More informationPlumbing Identification and Damage Assessment Guide
Plumbing Identification and Damage Assessment Guide *Please note that not all systems will be represented exactly by these diagrams and photos. As a vendor, it is required that you familiar yourself with
More informationGreenhouse Gas Implications of HVAC Upgrades in Multi-Unit Residential Buildings
Greenhouse Gas Implications of HVAC Upgrades in Multi-Unit Residential Buildings J A NUARY 2015 INTRODUCTION This Research Report explores best practices and approaches for reducing greenhouse gas (GHG)
More informationThis presentation premiered at WaterSmart Innovations. watersmartinnovations.com
This presentation premiered at WaterSmart Innovations watersmartinnovations.com Green Plumbing and Mechanical Code Supplement David Viola IAPMO Director of Special Services 1 IAPMO Group Association of
More informationHot Water Boilers and Controls Why Condensing Boilers are Different. Presented Oct. 14, 2008 Long Island Chapter, ASHRAE
Hot Water Boilers and Controls Why Condensing Boilers are Different Presented Oct. 14, 2008 Long Island Chapter, ASHRAE H.W. Boilers and Controls Major types of boilers Advantages and disadvantages Resistance
More informationENERGY STAR Certified Homes, Version 3 Cost & Savings Estimates
November 1, 2013 Contents ENERGY STAR Certified Homes, Version 3 Section 1: Executive Summary... 3 Section 2: Detailed Incremental Cost Estimates... 6 Section 3: Incremental Cost & Savings of the Thermal
More informationThis permit does not include replacement or upgrading of the existing electrical panel or service (a separate electrical permit must be obtained).
CITY OF MILPITAS Building & Safety Department 455 E. Calaveras Blvd. Milpitas, CA 95035 408-586-3240 www.ci.milpitas.ca.gov RESIDENTIAL AIR CONDITIONING, REPLACEMENT 1. PERMIT INFORMATION: The replacement
More informationAPC APPLICATION NOTE #112
#112 Best Practices for Deploying the InfraStruXure InRow SC By David Roden Abstract The InfraStruXure InRow SC (ACSC100 and ACSC101) is a self-contained air conditioner for server rooms and wiring closets.
More informationFEMP Designated Product Assessment for Commercial Gas Water Heaters
FEMP Designated Product Assessment for Commercial Gas Water Heaters Jim Lutz Energy Analysis Department Lawrence Berkeley National Laboratory Berkeley, CA 94720 April, 2010 This work was supported by the
More informationEXPRESS PERMITS (No Plan Check Required)
EXPRESS PERMITS (No Plan Check Required) Following are the lists of different types of construction for which an express permit can be issued. Express permits can be issued where work does not require
More informationTHE PEOPLE OF THE CITY OF LOS ANGELES DO ORDAIN AS FOLLOWS: Section 1. Article V of Chapter XII of the Los Angeles Municipal Code is added to read:
ORDINANCE NO. 1,;...8_U_8_2_2_ An ordinance adding Article V to Chapter XII, and amending Section 94.103.1.2.9, of the Los Angeles Municipal Code establishing water efficiency requirements for new development
More informationOne of the fundamental design elements that every
Preliminary Design Information Before starting the water system design, you must assemble a collection of information. This includes information from the owner, the local utility, and the architect. Things
More information4. Building HVAC Requirements
Table of Contents Page i Table of Contents 4. Building HVAC Requirements... 1 4.1 Overview... 1 4.1.1 Introduction and Organization... 1 4.1.2 What s New for the 2013 Standards... 2 4.1.3 Common System
More informationSelecting Energy Efficient New Windows in California
Selecting Energy Efficient New Windows in California www.efficientwindows.org Janurary 016 Zones 1. Meet the Energy Code & Look for the Windows must comply with your local energy code. Windows that are
More informationWater Heater Sizing TS 100 2 2 Saturday 2:15pm 5:15pm J. Joe Scott CPD, FASPE, LEED
Water Heater Sizing TS 100 2 2 Saturday 2:15pm 5:15pm J. Joe Scott CPD, FASPE, LEED Water Heater Sizing (to keep you out of hot water) What is a water heater? An immersion element in a bucket works, but
More informationCentauri. Condensing Fire Tube Water Boiler 399 to 1000 MBH
Centauri Condensing Fire Tube Water Boiler 399 to 1000 MBH Pre-mix surface burner with up to a 7-to-1 turndown NOx levels as low a 5 ppm at full rate Operates on 4" gas pressure shown with optional gauges
More informationENERGY STAR Residential Water Heaters: Final Criteria Analysis
ENERGY STAR Residential Water Heaters: Final Criteria Analysis Water heating represents between thirteen and seventeen percent of national residential energy consumption, making it the third largest energy
More informationCommercial Storage Tanks
Commercial Storage Tanks ALL THE STORAGE CHOICES YOU NEED FOR A TOTAL HOT WATER SUPPLY SYSTEM. INNOVATION AT A GLANCE A. O. SMITH IS THE BEST CHOICE FOR COMPLETE COMMERCIAL WATER HEATING AND STORAGE SYSTEMS
More informationIn 2012 the commercial sector natural gas demand was 201 billion cubic feet (bcf) or 2.01e + 23 thousand British thermal units (kbtu).
ENVIRONMENTAL SETTING The Southern California Gas Company (SoCalGas) provides natural gas to the City of Malibu. The City lies within the boundaries of the South Coastal distribution division. SoCalGas
More informationSolar Decathlon Load Profiling. Project Report
Solar Decathlon Load Profiling Project Report Prepared by Alexander Kon Alexander Hobby Janice Pang Mahan Soltanzadeh Prepared for TTP 289: A Path to Zero Net Energy 6/10/14 Executive Summary The U.S.
More informationMarket Potential Study for Water Heater Demand Management
Market Potential Study for Water Heater Demand Management Rebecca Farrell Troutfetter, Frontier Associates LLC, Austin, TX INTRODUCTION Water heating represents between 13 and 17 percent of residential
More informationHow to Reduce Energy Costs in Your Commercial Building
How to Reduce Energy Costs in Your Commercial Building Mark Steinmetz, Energy Advisor, GDS Associates, Inc., an ActOnEnergy Partner Mary Bentsen, Education and Training Coordinator SAIC, an Ameren Illinois
More informationpresents Hydraulic Separation Beyond Primary / Secondary Piping
presents Hydraulic Separation Beyond Primary / Secondary Piping This Webinar is exclusively sponsored and the property of Caleffi Hydronic Solutions. All rights reserved. October 2007 Modern compact boilers
More informationONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM REQUIREMENTS
Onsite Sewage Treatment & Disposal System Requirements ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM REQUIREMENTS 1. City of Ventura onsite sewage treatment and disposal system (Septic system) permit application
More informationThe main steam enters the building in the basement mechanical room; this is where the condensate line also leaves the building.
MSV: Square Footage: 24,844 No. of Floors: 1 Year Built: 1963 Type of Use: Lounge and dining area open all night for snacks Steam Water-cooled condenser, 50-Ton York unit with a 6 cylinder-reciprocating
More informationBetter Boilers. www.ibcboiler.com
Better Boilers FEATURING OUR IBC SUPREME SUPER COIL 316TI STAINLESS STEEL HEAT EXCHANGER. From the factory in Vancouver, our uniquely designed and engineered Super Coil VFC Heat Exchanger is the best Heat
More informationSample DTE Energy Rebate Programs Follow:
Sample DTE Energy Rebate Programs Follow: Refrigerator recycling (freezers, air conditioners & dehumidifiers too) Washing machines &programmable thermostats Forced air tune up Insulation and window replacement