ATPDesigner and ATP. Introduction and Overview
|
|
- Pamela Rodgers
- 8 years ago
- Views:
Transcription
1 EEUG Meeting One Day EEUG Course Protection Modeling with ATP and ATPDesigner September 14, 2005, Warsaw, Poland ATPDesigner and ATP Introduction and Overview Home Page: freenet.de/.de/atpdesigner DrMichaelIgel@aol aol.com Release: V
2 Table of Contents 1. Installation Procedure 2. Vision, Concept and Realization 3. File Management, Program Settings 4. Design of Network Elements 5. First Steps Designing Power Networks 6. Network Simulation and Diagram Viewer 7. Signal Analysis 8. Testing Protection Relays 2 2
3 1 Installation Procedure 3 3
4 Installation Procedure 1. Extract the Zip File ATPDesignerL.zip 2. Start Setup.exe 3. Follow Instructions 4 4
5 Installation Procedure Readme Text License Agreement Accept License Agreement Some Information about ATPDesigner and ATP Homepage: Important to read and understand 5 5
6 Installation Procedure Target Directory Selection Default Root Folder: C:\ATPDesigner Sub - Folders ATPSystem Data Doc Exe ATP Runtime System.NET Files,.PL4 Files, Temporary Files, etc. Some Helpful PDF-Files about ATPDesigner ATPDesignerL.exe, ATPDesigner.hlp ATPSystem ATP Runtime System Must Be Copied from the User into this Folder!!! Folder Must Contain the Files Listed Below! TPBIGG.exe STARTUP PlotXY.exe Default Folders can be Changed, but Program Settings Must be Adapted. 6 6
7 Installation Procedure Dialog Program Settings Default Folders of Program Settings are configured according the Folders of the Installation Procedure Both Sets of Folders Must be Adapted by Hand, if the User had Changed One. Name ot ATP Executable File (.EXE) Default DATA Folder: Data Folder of the ATP Runtime System: ATPSystem Folder of ATPDesigner.exe: Exe Windows OS Folder 7 7
8 Additonal Features The Installation Procedure creates a new Menu Item ATPDesigner Executable ATPDesigner Help File Uninstall Procedure Getting Started Update Documentation Shortcuts on the Desktop 8 8
9 Comments About Installation Don t forget to change Program Settings, if installation folders had been modified ATPDesigner starts ATP using the command line ATP System \ ATP Exec. File... C:\ATPDesigner\ATPSystem\TPBIGG.exe... Environment Variable GNUDIR ATPDesigner re-assignes the environment variable GNUDIR during the startup phase to the folder ATPSystem It s equal to Set GNUDIR = C:\ATPDesigner\ATPSystem\ This re-assignment is only valid as long as ATPDesigner is running! It is not necessary to modify the environment variable GNUDIR by Hand. 9 9
10 2 Vision Concept Solutions
11 About ATP ATP One of the Best Tools Worldwide to Simulate Electrical Power Networks One of the Best Tools Worldwide to Study Transient Phenomena High Number of Numerical Models of Power Network Elements Available More than 50 Years Experience in Simulation of Electrical Power Networks Used and Supported from the ATP Community Worldwide But Use of the Numerical Models are often Difficult for Beginners Long Experience Required to Use the Full Capability of ATP Input Data written in Text Files Easy to Make Faults Difficult to Detect Faults Simulation Results written in Text Files Difficult to Read Analyze Process Additional Tools Required Graphical User Interface (GUI), Diagram Viewer, Signal Analyzing Tools, Format Converting Tools, Printing Tools, Interface Tools, 11 11
12 What Does the User Need? ATP Users need an Integrated Development Environment to Simulate Power Networks Development = Design of the Electrical Power Network Creating Diagrams of Voltages and Currents Analyzing Voltages and Currents Tools using a Common Style Guide Tools which are Intuitive to Use Tools with a Common Graphical User Interface Tools which are Easy to Operate The Current Situation Tools are based on Different Style Guides Tools are using Different Operation Concepts Tools are not Integrated as Development Environment The Consequences Beginners Sporadic Users Experts ATP and the Tools are Difficult to Use Re-Understanding needs a lot of Time Tools are Acceptable, But to Improve 12 12
13 Vision and Concept Vision Tool which Helps Beginners to Start with ATP Tool which Supports also Sporadic Users and Experts Tool with a Graphical State of the Art User Interface Tool supporting all Important Development Aspects Design, Simulation, Diagrams, Signal Analysis, Format Converting, Tool which Covers ATP (= ATP runs Invisible in the Background) Tool which Translates ATP related settings to Engineering related Settings Tool which presents a User Friendly Interface for Settings Tool to Use ATP s Capabilities Testing Protection Relays Concept Integrated Simulation Environment Graphical User Interface according Microsoft Style Guide (e.g. Word, Excel, etc.) Developed with Microsoft Visual Studio Graphical User Interface to Design Power Networks (e.g. Visio, etc.) Easy to Use Operation Interface (e.g. Menus, Toolbars, Mouse Menus, etc.) Standardized Settings Dialogs designed for Electrical Engineers Integrated Diagram Viewer, Format Converter, Signal Analysis, etc. Support of Power Amplifiers via Communication Interfaces 13 13
14 One Tool - Different Views Main Menu Toolbar Power Network Multiple Views Integrated Diagram Viewer Toolbar and Status Bar 14 14
15 One Tool - Multiple Views 15 15
16 Default Power Network Click to Create a New Power Network Default Power Network Busbar Circuit Breaker Network Infeed Single-Circuit Line Busbar Circuit Breaker & Measuring Location 16 16
17 Menus and Toolbars Main Toolbar (see also Toolbars and Status Bar in Help File) Create a New Default.NET File Open an Existing File File Browser Write.ATP File Write.ATP File and Start ATP ATP runs in the background Open external diagram viewer Default: Plotxy Global Configuration Settings Network Configuration CMC Configuration Line Configuration Graphic Colors ATP Data Simulation related settings Single-Test Step Using CMC Test System Test Procedure Short Circuit Analysis Load Flow Analysis Presenting ATP s steady state results Format Converting Support of COMTRADE 17 17
18 Menus and Toolbars Toolbar for Network Design Mode (see also Right Mouse Button Menu) Add a new Busbar Network Infeed Load Impedance Grounding of Load Impedance RLC Series Impedance 2-Winding Transformer BCTRAN Transformer Autotransformer 3-Phase Sync. Generator Grounding System Text Frame 1-Phase Source 3-Phase Symmetrical Source Empirical Function (Type 1) Connection Measuring Probe Add a new Splitter Line Circuit Breaker Delete Deselect Copy & Paste Rotate 180 Rotate 90 Right Rotate 90 Left Move to Foreground Move to Background Lock / Unlock Shape of the Network Element Enable / Disable 18 18
19 Menus and Toolbars Toolbar for Network Elements and Diagrams Open Settings Dialogs Voltage and Current Transformer Saturation (Magnet. Characteristic) Fault Types Arc Resistance Fault Resistance Diagram related Buttons Selecting Voltages and Currents Scaling Factors Graphics Cursor Signal Analysis Results Fundamental Frequency Frequency Spectrum Vector Diagram Diagram related Buttons Diagram Settings Min, Max, Colors, Pen Thickness,... Zoom In and Out Refresh Diagram Signal Analysis Settings Calculating R, X, I rest, I diff,... Open Diagram View! Opens the.pl4 based diagram, which corresponds to the power network displayed in the active means topmost view 19 19
20 Windows like Menus Standard Hot Keys MRU File List New, Open, Save, Save As, Print,... Ctrl + N, Ctrl + O, Ctrl + S,
21 Right Mouse Button Menu Menu for Power Network Design Network elements can be added Most used settings dialogs can be opened Menu for Network Element related Settings Network element must be selected drawn in Light Grey Network element related features at the end Menu for Diagrams 21 21
22 Operating Concept Settings Dialog Double Click on the Graphical Representation of a Network Element Selected Network Element drawn in Light Grey Settings are defined from the Engineering Point of View Standardized Design of All Dialogs Selected Network Element via Double Click 22 22
23 Settings Dialog Close Dialog Saving Changed Settings Internal Name Close Dialog Ignoring Changed Settings User Defined Name Loading Default Settings Options Open Corresponding Chapter of the Help File Settings Disabled Settings Additional Data 23 23
24 Click on the Help Button Detailed Explanation of All Settings Snap Shot of the Settings Dialog Links to Related Topics 24 24
25 Information in the Help File Overview Getting Started 25 25
26 Information in the Help File Network Elements Network Infeed Busbar Lines Fault Type Generator Current and Voltage Transformer Splitter 3-Phase Source... Transformer 2-Winding BCTRAN Examples: Testing Vector Group Lines Single- and Double-Circuit Lines Line Models Examples: Series Compensated Line 26 26
27 Information in the Help File Testing Protection Devices Single-Step Test Measuring Operating Times Test Procedure for Automated Testing Interface to CMC Test System Supporting CMC156, CMC256, CMA156 Configuration of CMC Amplifiers Communication via CM Engine DLL General Information Menus Toolbars Hot Keys Errors Warnings 27 27
28 3 File Management, Program Settings 28 28
29 Open Files... Files can be opened as usual under Windows OS Open.. Most Recently Used (MRU) List File Browser (CTRL + X) 29 29
30 Easy to Use File Management Preferred Folder Double Click to Open Basic File Operations Explorer like File Tree File List of Preferred Folder Resizable Dialog 30 30
31 Files and File Extensions.NET File Contains All Information about the Network Elements Network Drawing Required to Draw the Network Graphics Electrical and Mechanical Settings Required to Write ATP Data Case File The.NET File Contains All Information about the Electrical Power Network. It is Absolutely Sufficient to Save Only the.net File. Secured by Checksums Should be Never Manipulated by Hand.NET - File = Container of the Electrical Power Network 31 31
32 Files and File Extensions.INI File Contains Only Program Related Settings Settings Independent from.net File Settings Stored in the EXE - Folder Automatically Created from ATPDesigner See Help File Content of the.ini File [ATPDesigner - Design and Simulation of Power Networks] VersionIniFile=Version INI File VersionATPDesigner=Version ExeFolder=C:\Mscpp\ATPDesigner DataFolder=C:\ATPDesigner\DATA CmEngineDllFolder=C:\ AtpFolder=C:\ATPDesigner\ATPSYSTEM AtpBrowserFolder=C:\ATP PL4FileFolder=C:\ATPDesigner\DATA AtpExeFilename=TPBIGG.EXE
33 Files and File Extensions.ATP File Contains the ATP based Models of the Electrical Power Network Created by ATPDesigner as Output File Can be Read from ATPDesigner to be Presented in a Text Editor Main Menu View.PL4 File Contains the Sampling Data of Voltages and Currents Calculated by ATP Created by ATP as Output File Can be Read from ATPDesigner to Create a Diagram.LST File Contains Additional Information about the Simulation Process e.g. Errors Created by ATP as Output File Can be Read from ATPDesigner to be Presented in a Text Editor 33 33
34 Files and File Extensions.NET - Files.INI - File COMTRADE.CFG - Files,.DAT - Files ATPDesigner.PL4 - Files.LST - File.ATP - File ATP Alternative Transients Program.LST - File.PL4 - File EEUG e.v. PlotXY 34 34
35 Program Settings Click on the Folder and Select a New Folder Version of the.ini - File Name ot ATP Executable File (.EXE) Load last.net File During Startup Default DATA Folder Folder of the ATP Runtime System Folder of Omicron CM Engine DLL Folder of ATPDesigner.exe Windows OS Folder 35 35
36 4 Design of Network Elements 36 36
37 Object Orientated Design Network Element = Object Object Orientated Design of Software and Data Information about the Graphical Representation Required for Panting the Network Graphics - Colors and Size - Position inside the View (x/y Coordinate) - Drawing Orientation - Connection to other Objects -... Transformer Information about the Electrical and Mechanical Settings Required for Writing the ATP Data Case File - U n, I n - P, Q, S - Line Length L - Impedance Z, Resistance R - Inductance L, Capacitance C, - Vector Group, Numerical Index - Helpful Calculators
38 Settings of Network Elements Settings are specified from Electrical Engineering Point of View The Vision ATP can be used Without ATP Expert Knowledge Neutral Point CB Nominal Voltages Vector Group Helpful Calculator Neutral Point solid grounded isloated compensated Neutral Point Impedance 38 38
39 Settings of Network Elements Example: Neutral Point of 2-Winding Transformer Neutral Point : solid grounded Neutral Point : isolated Neutral Point : compensated (Petersen Coil grounded) Neutral Point : compensated with CB in Parallel The Concept : Easy to Use Models ATPDesigner creates all ATP related Elements ATPDesigner creates all ATP related Node Names ATPDesigner makes ATP specific Requirements Invisible ATPDesigner designed from the Engineering Point of View 39 39
40 Design of Objects Detailled Design and Graphical Representation of a Transformer 1..N Snap Points to Connect Other Network Elements Snap Point = Node of the Electrical Power Network ONE Snap Point Can Only Connect ONE Other Snap Point (ONE - to - ONE) In ADDITION: Internal Nodes of the Network Element Trafosymbollänge X User Specific Name Mittelpunktdistanz M Trafoanschluss Trafodurchmesser D Snap Point Überdeckung y TRAFOIMPHOEHE Snap Point No Snap Point, but Internal Node Never to Connect TRAFOIMPBREITE Additional Information 40 40
41 Snap Points and Nodes Winding A: Snap Point to Connect Neutral-Point Node in the Power Network but no Snap Point Snap Point A Snap Point can be used to connect two network elements A snap point is always a node. The state of a snap point can be Connected, Not Connected or Internal. An Internal Snap Point can be not used to connect an other network element, BUT ATPDesigner will always create a node in the power network. Node Network elements will be connected by Common Nodes. ATPDesigner assigns a Node Name to any node of the power network. Specification of a Node Name: (RST)xxxxx, xxxxx = ATPDesigner re-numbers the node names after each operation Node names can be changed but must not changed after each operation F3 : Node names visible / invisible (see also Node Names in the Electrical Network in the Help File) 41 41
42 Snap Points and Nodes ATPDesigner checks Node Names before Writing the.atp - File Are Nodes NOT Connected? Are Node Names according the specification? If not, Error Message before Starting ATP Simulation Connected Node NOT Connected Nodes NOT Connected Busbar Node Isolated Network Element 42 42
43 Information of Colors Colors Can Be Set from the User 3-Phase Network Element Disabled Network Element NOT Taken into Account during the Simulation 1-Phase Network Element Circuit Breaker OPEN - CLOSE 43 43
44 5 First Steps Designing Power Networks 44 44
45 Basic Operations Operations are Only Enabled, if a Network Element had been First Selected. Selecting a Network Element = Left Mouse Button Click Selected Network Element drawn in Light Grey Selected Network Elements can be Moved, Deleted, Copied, Enabled/Disabled, Locked/Unlocked, etc. Isolated and Selected Network Elements can be Rotated In Addition Disabled Network Elements will be Ignored Creating Electrical Network written in the.atp - File Selected Network Element Isolated Network Element Disabled Network Element 45 45
46 Basic Operations Locked or Unlocked Shape of a Network Element ATPDesigner Supports Network Elements with a Fixed Shape and with a Flexible Shape. Lock / Unlock Status will be indicated for Selected Network Elements Network Element with Locked Shape Network Element with Unlocked Shape Moving Locked Lines Shape of the Line will be Fixed Moving Unlocked Lines Shape of the Line can be changed using a Rubber Band 46 46
47 Basic Operations Selecting Several Network Elements Hold Down SHIFT & Left Mouse Button, Click on Network Elements Selected Network Elements drawn in Light Grey Moving Selected Network Elements Move Mouse Cursor Over Selected Network Elements Hand Appears Press Left Mouse Button and Move Selected Network Elements Release Left Mouse Button at the New Position 47 47
48 Add Transformer ATPDesigner identifies NOT Connected Snap Points 1. Click on Toolbar Button or Select in Right Mouse Button Menu 2. Select the Drawing Direction Right 3. Move Mouse Cursor to a NOT Connected Node 4. Release Mouse Button 5. ATPDesigner Creates New Network Element 6. ATPDesigner Opens Automatically the Settings Dialog 48 48
49 Open Settings Dialog 49 49
50 Power Network Design 1. Select the Network Elements to Move (Light Grey) 2. Move Mouse Cursor to the Node 3. Hold Left Mouse Button Down 4. Move Selected Network Elements to a NOT Connected Node 50 50
51 Power Network Design Checking Network Topology ATPDesigner checks the New Topology of the Power Network, before finalising Are All Required Snap Points NOT Connected? If YES, Finalize the Modified Network Topology If NO, Error Message will be Displayed Redo the Modification of the Network Topology 51 51
52 Add Load Impedance 1. Click on the Toolbar Button 2. Select the Drawing Direction Right 3. Move Mouse Cursor to a NOT Connected Node 4. Release Mouse Button 5. ATPDesigner Creates New Network Element 6. ATPDesigner Opens Automatically the Settings Dialog 7. Enable Solid Grounded 52 52
53 CB with Measuring Location ATPDesigner supports Circuit Breakers with Measuring Location Measuring Location to the Right or Left of the CB Voltage Transformer (VT) and Current Transformer (CT) Model Evaluation Release: Transformation Ratio Available in Full Release Capacitive Voltage Transformer (CVT) CT with Saturation (Magnetization Characteristic) 53 53
54 CB with Measuring Location Measuring Locations Assigned to Circuit Breaker Cb Measuring Locations available with VT and CT Models Cb1..5 can be only Deleted, if Assigned Measuring Location had been First Deactivated Activate / Deactivate Assigned Measuring Locations First Select Cb1..5 (drawn in Light Grey) Open Settings Dialog via Right Mouse Button Menu 54 54
55 CB with Measuring Location Cb1..5 and Testing Protection Relays Testing Distance Protection or Overcurrent Protection Tests in Radial Networks Use Cb1 with Assigned Measuring Location 1 Monitoring at ONE Monitoring Point Tests in Meshed Networks Use Cb1 and Cb2 with Assigned Measuring Location 1 and 2 Monitoring at TWO Monitoring Points Testing Differential Protection 2-Winding Transformer Protection or 2-Terminal Line Differential Protection Use Cb1 and Cb2 with Assigned Measuring Location 1 and 2 Monitoring at TWO Monitoring Points 55 55
56 CB with Measuring Location 56 56
57 CB1..5 and CT Saturation Saturation of Current Transformers One of the Most Critical Problems Regarding Protection Schemes It is Necessary to Test the Behaviour of Protection Relays in Case of CT Saturation Determine the Influence of the Tripping Times Determine the Overreaching or Underreaching ATP Numerical Models for Non-Linear Inductances Available (e.g. Type 98) But CT Model isn t Yet Available, Must be First Specified ATPDesigner Current Transformer Only Available for CB 1..5 Numerical Model of a TPX Current Transformer can be Enabled Options: Hysterisis and Remanence are both Available See more Details in the Help File CT Saturation Characteristic 57 57
58 CB1..5 and CT Saturation Numerical Model of the Current Transformer Enabled for Circuit- Breaker Cb 1 Example Transformation Ratio = 1000 / 1 A S n = 5 VA R b = 2 Ohm N = 10 Total Error F g = 1% 58 58
59 CB1..5 and CT Saturation ATP based Model Transformation Ration Ideal Transformer Magnetization Characteristic Type 98 L (i) Internal Burden and External Burden Burden Impedance Create a Diagram using OUTP01/2/3 Currents at the Secondary Circuit of the CT CT Saturation 59 59
60 CB1..5 and CT Saturation The Internal Currents of the Current Transformer OUTP01 Current to be Injected into the Protection Relay IAS_M1 Current at Secondary Circuit of the CT WITHOUT Saturation RICTM1 Magnetization Current of the CT 60 60
61 6 Network Simulation and Diagram Viewer 61 61
62 ATP Data: Simulation Data Before Starting the Simulation it is necessary to specify some settings, which are related to the simulation process. Time Overall Length of the Calculated Data in Cycles Prefault Time before a Line Fault occurs dt Sampling Rate of the Data stored in the.pl4 File Out Repetition of the Test Step, related to CMC Test System Step Number of Calculation Steps between two Samples stored in the.pl4 - File 62 62
63 ATP Data: Simulation Data Advantage of dt and Step It is often a must to use a high internal sampling frequency caused by complex and high-sophisticated numerical models e.g. LINE CONSTANTS. On the other hand it is often sufficient to write the sampling values of voltages and currents in the.pl4 file using a low sampling frequency. Both requirements can be set independent from each other with the both settings dt Step. Example: Testing Protection Relays The typical sampling frequency of protection relays is about 1000Hz. If a test engineer uses e.g. an Omicron CMC Test System, it is sufficient to use an output sampling frequency of about 5000Hz = 0.2ms in the.pl4 file. Therefore the settings dt should be set to dt = 0.2ms. The internal ATP related sampling frequency can now be set dependend on the requirements of the used numerical models
64 First Calculating Voltages, etc. ATPDesigner starts ATP as a Background Process Click on the Toolbar Botton or Use the Right Mouse Button Menu or Use Hotkey CTRL + R Open Corresponding.PL4 File Select Node Names Move it to the Right List Node IAP_M1 Current Phase A Primary Measuring Location 1 Node IBP_M1 Current Phase B Primary Measuring Location 1 Node ICP_M1 Current Phase C Primary Measuring Location
65 TACS Interface for Diagrams ATPDesigner connects Internal Nodes to TACS Nodes Nodes will be Re-Numbered if the Network Topology had been Changed BUT: TACS Nodes are Fixed TACS Output Nodes for CB 1..5 with Measuring Location Probes Advantage Signal List for Diagrams are Fixed if Network Topology had been Changed Easy to Refresh Diagrams after Modifications 65 65
66 Creating a Diagram ATPDesigner creates a New Diagram in a New View Node Names Related to Graphics Cursor Diagram related Toolbar 66 66
67 Enable Fault Type ATPDesigner supports Lines 1..3 with Integrated Fault Location Open the Dialog Fault Types Select Fault Type ABCG Default: Fault at the Beginning of the Line = 0% Fault can be MOVED Holding Down Left Mouse Button Move the Fault Location to 50% Recalculate Voltages and Currents Open Corresponding.PL4 File Refresh Diagram 67 67
68 Setting Fault Location An Alternative Method to Set the Fault Location Faults (Short-Circuits) can be Enabled for Lines 1..3 Therefore: Fault Location can be Set in the Line Settings Dialog 68 68
69 Open Corresponding Diagram ATPDesigner presents the Modified Diagram 2 Graphics Cursor Enable Graphics Cursor for Signal Analyzing Purposes Sampled Values Red Cursor 1 Cycle Sampled Values Grey Cursor Time [s] 69 69
70 7 Signal Analysis 70 70
71 Signal Analysis Settings Open Dialog Diagram Settings DFT Window = 1 Cycle Time distance between the Graphic Cursor DFT f = 50 Hz Filtering Frequency of DFT Should be Fundamental Frequency of the Power Network Can be set Independent of the Power Network Frequency DFT Window DFT Window can be moved using Cursor Left & Cursor Right Size of the DFT Window keeps constant Graphical Cursor can be set independent with Mouse Left & Mouse Right 71 71
72 DFT Algorithm Discrete Fourier Transformation One of the Most Important Analyzing Methods for Electrical Engineers Used for Harmonic Analysis f n Continuous Signal Measured Voltages and Currents Measured in Real Power Networks t n f n Sampled Signal Voltages and Currents calculated using ATP Sampled values stored in.pl4 - File Sampling Frequency e.g. 1 khz t n
73 DFT Algorithm Calculation of a Complex Vector a + j b Real Part N n a k = f (nt a) cos 2πk N n=0 N Imaginary Part N n b k = f (nt a) sin 2πk N n=0 N f a : Sampling Frequency in Hz T a = 1 / f a : Size of the DFT Window in Seconds N : Number of Samples in the DFT Window k : DFT Filtering Frequency k = 0 : DC Component k = 1 : Fundamental Frequency e.g. 50 Hz k = 1 : 1. Harmonic e.g. 100 Hz... dt : Output Sampling Rate in.pl4 File Internal (ATP) Sampling Frequency f int = Step / dt 73 73
74 DFT Example f(t k) = 100 sin(2π50hz t k) + 10 sin(2π100hz t k) + 20 sin(2π350hz t k) DFT f = 50 Hz 1. Harmonic = 100 Hz 6. Harmonic = 350 Hz 74 74
75 Fundamental Frequency ATPDesigner supports Signal Analysis using DFT Algorithm 1. Open a Diagram e.g. Reading a.pl4 - File 2. Enable Graphics Cursor 3. Open Dialog of Signal Analysis Results Fundamental Frequency Node Names Frequency Spectrum Frequency Spectrum Bar Diagram R.M.S Peak Amount Phase Phase Difference 75 75
76 Frequency Spectrum 1. Select One of the Nodes in the List 2. Click on the Tab Harmonics Frequency Amount Frequency Spectrum of Selected Signal Phase Phase Difference Related to 50 Hz Copy List to Clipboard 76 76
77 Bar Diagram Click on the Tab Spectrum Top Most Window Copy to Clipboard Select Maximum Frequency to Show Unit to Select Resizable Dialog 77 77
78 Vector Diagram Open the Vector Diagram Copy to Clipboard Scaling Factor Resizable Dialog 78 78
79 8 Testing Protection Relays 79 79
80 Testing Protection Relays Vision Protection Relays shall be tested as Realistic as Possible Test Data according the Physical Conditions in Power Networks Transient Phenomena shall be taken into account Test Procedures shall be Automated to Increase the Number of Test Steps Requirements ATP is able to Simulate the Behaviour of Electrical Power Networks ATP Output Data : Sampled Data of Voltages and Currents Test System required to Translate Sampled Data to Volts and Amps D/A Converter 16 Bit Frequency Range Hz Voltage Output up to 150V (V nom = V) Current Output up to 50 A (I nom = 1A or 5A, I max 100 I nom ) Monitoring Binary Signals (f a 0,5ms) Communication Interface between PC and Test System to Automate Test Procedures 80 80
81 ATPDesigner and CMEngine ATPDesigner supports CMC Test Systems of Omicron Using the Communication Interface CM Engine for Control and Automation Voltages and Currents Transfered to CMC Test System as Sampled Data CMC Test System Translates Sampled Data to Volts and Amps CMC Test System Monitors Binary Signal with 100µs Resolution CMC Test System = Recording System for Binary Signals Procedure Design of the Power Network with ATPDesigner Calculating Voltages and Currents with ATP as Primary Signals ATPDesigner Transforms Voltages and Currents to Secondary Signals Circuit Breaker Cb1..5 supporting Numerical CT and VT Models Circuit Breaker Cb1..2 designed for Data Interface to CMC Test System Test Methods in ATPDesigner Single-Test Step Test Procedure 81 81
82 CM Engine Support ATPDesigner communicates with CMC Test Systems via Parallel Port Interface ATPDesigner converts Sampled Data of.pl4 File Internally to CMC Data Format ATPDesigner transfers Sampled Data to CMC Test System ATPDesigner reads out Monitoring Data (Binary Inputs) from CMC Test System after Finalizing Test Step Monitoring Data = Tripping Times Test Procedure In Addition ATPDesigner writes Test Report 82 82
83 Output Device: CMC Easy to Use: CMC Test System Select Output Device = CMC Test System Measuring Location 1 will be Automatically Assigned to the CMC Test System Primary Voltages V AG, V BG, V CG Primary Currents I A, I B, I C Substation CT and VT Secondary Voltages OUTP04/05/06 Secondary Currents OUTP01/02/03 CMC Test System via CM Engine Interface Protection Relay 83 83
84 TACS Interface See Node Help about Specification of Node Names Secondary Circuit of Substation Transformer Measuring Location 1 (Cb1) V AG Measuring Location 1 (Cb1) V BG Measuring Location 1 (Cb1) V CG Measuring Location 1 (Cb1) I A Measuring Location 1 (Cb1) I B Measuring Location 1 (Cb1) I C OUTP04 OUTP05 OUTP06 OUTP01 OUTP02 OUTP03 Start Single Test Step Define Test Procedure ATPDesigner shows Operating Times ATPDesigner writes Test Report 84 84
85 Operating Times Single-Step Test Presenting the Last Measured Operating Times 10 Binary Inputs of CMC Test System LED Indication Measured Operating Times 85 85
86 Operating Times.TRP File: Operating Times in a Diagram 86 86
87 Test Procedure 2 Test Levels Monitoring Binary Inputs Level 1 Settings Test Level 1 = Master Level Test Level 2 = Slave Level, Operated for all Test Level 1 Steps 87 87
88 Test Procedure Level 1 Setting Level 2 Setting 88 88
89 Test Report Example: Test Procedure for Distance Protection P430 Test Report contains the Results which are also presented in the Operating Times Dialog. Level 1 Fault Location % of the Line Length, Step 10% Level 2 Point on Wave , Step 30 Repetitions 10 times per Network Simulation Results Minimum Tripping Time Maximum Tripping Time Mean Value 89 89
90 ATPDesigner and CMC See Additional Information in the Help File Measuring Operating Times of a Protection Device Correction of Measured Operating Times Automated Test Procedures Concept of Test Procedures How to define a Test Procedure Test Level 2 Test Procedure Comments Monitoring Ranges Operating Times Dialog for Test Procedures Configuration of CMC Test System Menu Item Configuration of Amplifiers Connecting CMC Test System During Startup How ATPDesigner Connects the CMC Test System Configuration of Omicron CMC Test Systems 90 90
91 Demonstration Distance Protection P430 + CMC156 Reactive Reach = 80% of the Line Length Power Network Measuring Location 1 assigned to Circuit-Breaker Cb1 Substation VT Ratio Substation CT Ratio 91 91
Application-oriented testing of line differential protection end to end in the field using the corresponding RelaySimTest template
Application Note Application-oriented testing of line differential protection end to end in the field using the corresponding RelaySimTest template Author Jens Baumeister jens.baumeister@omicron.at Date
More informationCopyright 2011 Linear Technology. All rights reserved.
Copyright. All rights reserved. LTspice IV Getting Started Guide 2 Benefits of Using LTspice IV Stable SPICE circuit simulation with Unlimited number of nodes Schematic/symbol editor Waveform viewer Library
More informationPaladin DesignBase Toolbar Functions
Paladin DesignBase Toolbar Functions Power Analytics Corporation 10805 Rancho Bernardo Road, Suite 270 San Diego, California 92127 U.S.A. U.S. Toll Free Phone: 800-362-0603 Fax: 858-675-9724 www.poweranalytics.com
More informationFREJA Win Software for FREJA relay testing system
Software for FREJA relay testing system A Megger Group Company Software for FREJA relay testing system In FREJA Win, the all-round General instrument program serves as a convenient, easy to understand,
More informationManual. Sealer Monitor Software. Version 0.10.7
Manual Sealer Monitor Software Version 0.10.7 Contents 1 Introduction & symbols 1 2 Installation 2 2.1 Requirements 2 2.2 Installation process 2 3 Menu & Tooblar 5 3.1 File menu 5 3.2 Print menu 6 3.3
More informationTest & Data Management Software
Test & Data Management Software TDMS protective relays energy meters transducers power quality CT-VT-PT transformers ground grid circuit breakers batteries surge arresters The Integrated Testing Solution
More informationHow To Run A Factory I/O On A Microsoft Gpu 2.5 (Sdk) On A Computer Or Microsoft Powerbook 2.3 (Powerpoint) On An Android Computer Or Macbook 2 (Powerstation) On
User Guide November 19, 2014 Contents 3 Welcome 3 What Is FACTORY I/O 3 How Does It Work 4 I/O Drivers: Connecting To External Technologies 5 System Requirements 6 Run Mode And Edit Mode 7 Controls 8 Cameras
More informationTDMS Test & Data Management Software
Test & Data Management Software TDMS protective relays energy meters transducers power quality CT-VT-PT transformers ground grid circuit breakers batteries surge arresters The Integrated Testing Solution
More informationAvaya Network Configuration Manager User Guide
Avaya Network Configuration Manager User Guide May 2004 Avaya Network Configuration Manager User Guide Copyright Avaya Inc. 2004 ALL RIGHTS RESERVED The products, specifications, and other technical information
More informationLab 3: Introduction to Data Acquisition Cards
Lab 3: Introduction to Data Acquisition Cards INTRODUCTION: In this lab, you will be building a VI to display the input measured on a channel. However, within your own VI you will use LabVIEW supplied
More informationNVMS-1200. User Manual
NVMS-1200 User Manual Contents 1 Software Introduction... 1 1.1 Summary... 1 1.2 Install and Uninstall... 1 1.2.1 Install the Software... 1 2 Login Software... 3 2.1 Login... 3 2.2 Control Panel Instruction...
More informationCurrent and voltage measuring relays
Current and voltage measuring relays RXIK 1, RXEEB 1 and Page 1 Issued June 1999 Changed since July 1998 Data subject to change without notice RXIK 1 RXEEB 1 (SE980082) (SE980081) (SE970869) Features Application
More informationManual Analysis Software AFD 1201
AFD 1200 - AcoustiTube Manual Analysis Software AFD 1201 Measurement of Transmission loss acc. to Song and Bolton 1 Table of Contents Introduction - Analysis Software AFD 1201... 3 AFD 1200 - AcoustiTube
More informationThe corresponding control ladder program is shown at below: The content of element comment will be built is shown below
Introduction This tutorial explains how to build an application by using the Winproladder programming package to write a ladder control program. In this tutorial we will not tackle the advanced features
More informationStrikeRisk v6.0 IEC/EN 62305-2 Risk Management Software Getting Started
StrikeRisk v6.0 IEC/EN 62305-2 Risk Management Software Getting Started Contents StrikeRisk v6.0 Introduction 1/1 1 Installing StrikeRisk System requirements Installing StrikeRisk Installation troubleshooting
More information2010 Ing. Punzenberger COPA-DATA GmbH. All rights reserved.
2010 Ing. Punzenberger COPA-DATA GmbH All rights reserved. Distribution and/or reproduction of this document or parts thereof in any form are permitted solely with the written permission of the company
More informationUser Manual WatchPower
User Manual WatchPower Management Software for Inverter Table of Contents 1. WatchPower Overview... 1 1.1. Introduction... 1 1.2. Features... 1 2. WatchPower Install and Uninstall... 1 2.1. System Requirement...
More informationUnderstand the Sketcher workbench of CATIA V5.
Chapter 1 Drawing Sketches in Learning Objectives the Sketcher Workbench-I After completing this chapter you will be able to: Understand the Sketcher workbench of CATIA V5. Start a new file in the Part
More informationNVMS - 1000 USER MANUAL. Version 2.1.0
NVMS - 1000 USER MANUAL Version 2.1.0 Contents 1 Software Introduction... 1 1.1 Summary... 1 1.2 Operation Environment... 1 1.3 Install and Uninstall... 2 1.3.1 Install the Software... 2 1.3.2 Uninstall
More informationTABLE OF CONTENTS. INTRODUCTION... 5 Advance Concrete... 5 Where to find information?... 6 INSTALLATION... 7 STARTING ADVANCE CONCRETE...
Starting Guide TABLE OF CONTENTS INTRODUCTION... 5 Advance Concrete... 5 Where to find information?... 6 INSTALLATION... 7 STARTING ADVANCE CONCRETE... 7 ADVANCE CONCRETE USER INTERFACE... 7 Other important
More informationCATIA: Navigating the CATIA V5 environment. D. CHABLAT / S. CARO Damien.Chablat@irccyn.ec-nantes.fr
CATIA: Navigating the CATIA V5 environment D. CHABLAT / S. CARO Damien.Chablat@irccyn.ec-nantes.fr Standard Screen Layout 5 4 6 7 1 2 3 8 9 10 11 12 13 14 15 D. Chablat / S. Caro -- Institut de Recherche
More informationArcGIS. Tips and Shortcuts. for Desktop
ArcGIS Tips and Shortcuts for Desktop Map Navigation Refresh and redraw the display. F5 Suspend the map s drawing. F9 Zoom in and out. Center map. Roll the mouse wheel backward and forward. Hold down Ctrl
More informationUser s Manual. Management Software for Inverter
WatchPower User s Manual Management Software for Inverter Table of Contents 1. WatchPower Overview... 2 1.1. Introduction... 2 1.2. Features... 2 2. WatchPower Install and Uninstall... 2 2.1. System Requirement...
More informationDatabase Studio is the new tool to administrate SAP MaxDB database instances as of version 7.5.
1 2 3 4 Database Studio is the new tool to administrate SAP MaxDB database instances as of version 7.5. It replaces the previous tools Database Manager GUI and SQL Studio from SAP MaxDB version 7.7 onwards
More informationViewPower. User s Manual. Management Software for Uninterruptible Power Supply Systems
ViewPower User s Manual Management Software for Uninterruptible Power Supply Systems Table of Contents 1. ViewPower Overview... 2 1.1. Introduction...2 1.2. Structure...2 1.3. Applications...2 1.4. Features...2
More information2006-2011, SHAPE Services www.shapeservices.com
RDM+ Remote Desktop for Mobiles For Java-powered phones and Symbian OS devices 1. Installing RDM+ Client on a phone... 2 Internet connection... 2 2. Registration and trial... 3 3. Address book... 3 4.
More informationUser Manual. Motion Analyzer Software Version 7.00
User Manual Motion Analyzer Software Version 7.00 Important User Information Solid-state equipment has operational characteristics differing from those of electromechanical equipment. Safety Guidelines
More informationRemote Monitoring and Control of the R&S FSV with a Web Browser
Rohde & Schwarz Products: R&S FSV3, R&S FSV7, R&S FSV13, R&S FSV30 Remote Monitoring and Control of the R&S FSV with a Web Browser Application Note This application note describes remote operation or monitoring
More informationBuilding a Simulink model for real-time analysis V1.15.00. Copyright g.tec medical engineering GmbH
g.tec medical engineering GmbH Sierningstrasse 14, A-4521 Schiedlberg Austria - Europe Tel.: (43)-7251-22240-0 Fax: (43)-7251-22240-39 office@gtec.at, http://www.gtec.at Building a Simulink model for real-time
More informationEE 242 EXPERIMENT 5: COMPUTER SIMULATION OF THREE-PHASE CIRCUITS USING PSPICE SCHEMATICS 1
EE 242 EXPERIMENT 5: COMPUTER SIMULATION OF THREE-PHASE CIRCUITS USING PSPICE SCHEMATICS 1 Objective: To build, simulate, and analyze three-phase circuits using OrCAD Capture Pspice Schematics under balanced
More informationInstruction Manual. Applied Vision is available for download online at:
Applied Vision TM 4 Software Instruction Manual Applied Vision is available for download online at: www.ken-a-vision.com/support/software-downloads If you require an Applied Vision installation disk, call
More informationChapter 1. Creating Sketches in. the Sketch Mode-I. Evaluation chapter. Logon to www.cadcim.com for more details. Learning Objectives
Chapter 1 Creating Sketches in Learning Objectives the Sketch Mode-I After completing this chapter you will be able to: Use various tools to create a geometry. Dimension a sketch. Apply constraints to
More informationCATIA Basic Concepts TABLE OF CONTENTS
TABLE OF CONTENTS Introduction...1 Manual Format...2 Log on/off procedures for Windows...3 To log on...3 To logoff...7 Assembly Design Screen...8 Part Design Screen...9 Pull-down Menus...10 Start...10
More informationInfor ERP BaanIV / Baan 5.0 / LN 6.1. User's Guide for Worktop 2.4
Infor ERP BaanIV / Baan 5.0 / LN 6.1 User's Guide for Worktop 2.4 Copyright 2008 Infor All rights reserved. The word and design marks set forth herein are trademarks and/or registered trademarks of Infor
More informationPower Log PC Application Software
Power Log PC Application Software Users Manual May 2007 Rev. 1, 5/08 2007-2008 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks
More informationSitecore InDesign Connector 1.1
Sitecore Adaptive Print Studio Sitecore InDesign Connector 1.1 - User Manual, October 2, 2012 Sitecore InDesign Connector 1.1 User Manual Creating InDesign Documents with Sitecore CMS User Manual Page
More informationMulti Channel software
Multi Channel software User manual TiePie engineering Copyright c 2014 TiePie engineering. All rights reserved. Revision 1.05, February 2014 Despite the care taken for the compilation of this user manual,
More informationCitrix EdgeSight for Load Testing User s Guide. Citrix EdgeSight for Load Testing 3.8
Citrix EdgeSight for Load Testing User s Guide Citrix EdgeSight for Load Testing 3.8 Copyright Use of the product documented in this guide is subject to your prior acceptance of the End User License Agreement.
More informationIntroduction to Simulink
Introduction to Simulink MEEN 364 Simulink is a software package for modeling, simulating, and analyzing dynamical systems. It supports linear and nonlinear systems, modeled in continuous time, sampled
More informationFREJA 300 Relay Testing System
Relay Testing System A Megger Group Company FREJA 300 Relay testing system The FREJA 300 relay testing system is a computer-aided relay testing and simulation system. The weight of FREJA 300 is only 15
More informationContouring and Advanced Visualization
Contouring and Advanced Visualization Contouring Underlay your oneline with an image Geographic Data Views Auto-created geographic data visualization Emphasis of Display Objects Make specific objects standout
More informationUSER AND INSTALLATION MANUAL
Revision 1 - October 2013 User and installation manual O-link The manufacturer OWANDY reserves the right to make modifications to its products or to their specifications in order to improve the performance,
More informationNDA-30141 ISSUE 1 STOCK # 200893. CallCenterWorX-Enterprise IMX MAT Quick Reference Guide MAY, 2000. NEC America, Inc.
NDA-30141 ISSUE 1 STOCK # 200893 CallCenterWorX-Enterprise IMX MAT Quick Reference Guide MAY, 2000 NEC America, Inc. LIABILITY DISCLAIMER NEC America, Inc. reserves the right to change the specifications,
More informationNetMeeting - User Guide
NetMeeting - User Guide 1. To Host a Meeting 1. On the Call menu, click Host Meeting. 2. In Meeting Name, type the meeting name or leave it set to Personal Conference. 3. In Password, type the meeting
More informationWindows 10: A Beginner s Guide
Windows 10: A Beginner s Guide Copyright 2014 Conceptual Kings. All are rights reserved. This book or any portion thereof may not be reproduced or used in any manner whatsoever without the express written
More informationBasic Excel Handbook
2 5 2 7 1 1 0 4 3 9 8 1 Basic Excel Handbook Version 3.6 May 6, 2008 Contents Contents... 1 Part I: Background Information...3 About This Handbook... 4 Excel Terminology... 5 Excel Terminology (cont.)...
More informationOhio University Computer Services Center August, 2002 Crystal Reports Introduction Quick Reference Guide
Open Crystal Reports From the Windows Start menu choose Programs and then Crystal Reports. Creating a Blank Report Ohio University Computer Services Center August, 2002 Crystal Reports Introduction Quick
More informationQUICK START GUIDE. SG2 Client - Programming Software SG2 Series Programmable Logic Relay
QUICK START GUIDE SG2 Client - Programming Software SG2 Series Programmable Logic Relay SG2 Client Programming Software T he SG2 Client software is the program editor for the SG2 Series Programmable Logic
More informationGelAnalyzer 2010 User s manual. Contents
GelAnalyzer 2010 User s manual Contents 1. Starting GelAnalyzer... 2 2. The main window... 2 3. Create a new analysis... 2 4. The image window... 3 5. Lanes... 3 5.1 Detect lanes automatically... 3 5.2
More informationModule 1: Getting Started With Altium Designer
Module 1: Getting Started With Altium Designer Module 1: Getting Started With Altium Designer 1.1 Introduction to Altium Designer... 1-1 1.1.1 The Altium Designer Integration Platform...1-1 1.2 The Altium
More informationTable Of Contents. iii
PASSOLO Handbook Table Of Contents General... 1 Content Overview... 1 Typographic Conventions... 2 First Steps... 3 First steps... 3 The Welcome dialog... 3 User login... 4 PASSOLO Projects... 5 Overview...
More informationTransmitter Interface Program
Transmitter Interface Program Operational Manual Version 3.0.4 1 Overview The transmitter interface software allows you to adjust configuration settings of your Max solid state transmitters. The following
More informationRemote Monitoring and Control of the R&S FSL with a Web Browser
Rohde & Schwarz Products: R&S FSL3, R&S FSL6, R&S FSL18 Remote Monitoring and Control of the R&S FSL with a Web Browser Application Note This application notes describes remote operation or monitoring
More informationLAB1 INTRODUCTION TO PSS/E EE 461 Power Systems Colorado State University
LAB1 INTRODUCTION TO PSS/E EE 461 Power Systems Colorado State University PURPOSE: The purpose of this lab is to introduce PSS/E. This lab will introduce the following aspects of PSS/E: Introduction to
More informationSelecting Current Transformers Part 1 By Darrell G. Broussard, P.E.
By Darrell G. Broussard, P.E. Introduction: As engineers, we are aware that electrical power systems have grown. How much have they grown? When was the last time you specified a 2400-volt system, a 4160-volt
More informationGetting Started. A Getting Started Guide for Locum RealTime Monitor. Manual Version 2.1 LOCUM SOFTWARE SERVICES LIMITED
Getting Started A Getting Started Guide for Locum RealTime Monitor Manual Version 2.1 LOCUM SOFTWARE SERVICES LIMITED Locum House, 84 Brown Street, Sheffield, S1 2BS, England Telephone: +44 (0) 114 252-1199
More informationOPERATION MANUAL. MV-410RGB Layout Editor. Version 2.1- higher
OPERATION MANUAL MV-410RGB Layout Editor Version 2.1- higher Table of Contents 1. Setup... 1 1-1. Overview... 1 1-2. System Requirements... 1 1-3. Operation Flow... 1 1-4. Installing MV-410RGB Layout
More informationSHARP Digital Signage Software Pro PN-SS05 OPERATION MANUAL
SHARP Digital Signage Software Pro PN-SS05 Version 4.1 OPERATION MANUAL Contents Introduction... 2 Precautions on Use...2 Trademarks...2 How to Read this Manual...3 Definitions...3 Installing/Launching...
More informationT 3000. Substation Maintenance and Commissioning Test Equipment
T 3000 Substation Maintenance and Commissioning Test Equipment Multi function system for testing substation equipment such as: current, voltage and power transformers, all type of protection relays, energy
More informationUser s Guide for version 5 Page
Network Management Interface Catalog VPi 32.15E For use with these ATS products: 7000 & 4000 Series (Group 5 Controller) Series 300 (Group 1 Controller), and 940, 962, 436, 434, 447, 448 (Group 6A/7A Control
More informationGenerative Drafting. Page 1 1997 2001 DASSAULT SYSTEMES. IBM Product Lifecycle Management Solutions / Dassault Systemes
Generative Drafting Page 1 Tutorial Objectives Description This Tutorial is an introduction to Generative Drafting. Message To show how CATIA V5 allows the user to automatically generate associative drafting
More informationCONCEPT-II. Overview of demo examples
CONCEPT-II CONCEPT-II is a frequency domain method of moment (MoM) code, under development at the Institute of Electromagnetic Theory at the Technische Universität Hamburg-Harburg (www.tet.tuhh.de). Overview
More informationSharing Files and Whiteboards
Your user role in a meeting determines your level of file sharing. The type of files you can share include documents, presentations, and videos. About Sharing Files, page 1 Changing Views in a File or
More informationSAP Business Intelligence (BI) Reporting Training for MM. General Navigation. Rick Heckman PASSHE 1/31/2012
2012 SAP Business Intelligence (BI) Reporting Training for MM General Navigation Rick Heckman PASSHE 1/31/2012 Page 1 Contents Types of MM BI Reports... 4 Portal Access... 5 Variable Entry Screen... 5
More informationDell SonicWALL SRA 7.5 Secure Virtual Meeting and Secure Virtual Assist
Dell SonicWALL SRA 7.5 Secure Virtual Meeting and Secure Virtual Assist Document Scope This document describes how to configure and use the Dell SonicWALL SRA Secure Virtual Meeting feature and the Dell
More informationSoftware version 1.1 Document version 1.0
Software version 1.1 Document version 1.0 1 RDNET PROTOCOL OVERVIEW... 2 1.1 Network description... 2 1.2 Connection topology... 2 2 SOFTWARE BASIC OPERATIONS... 3 2.1 Main View elements... 3 2.2 Scanning
More informationCitrix EdgeSight for Load Testing User s Guide. Citrx EdgeSight for Load Testing 2.7
Citrix EdgeSight for Load Testing User s Guide Citrx EdgeSight for Load Testing 2.7 Copyright Use of the product documented in this guide is subject to your prior acceptance of the End User License Agreement.
More informationStatel Robot Service Help. 2004... Eurostat
Statel Robot Service Help 2 SRS help 1 Introduction 1.1 Overview The objective of the STATEL Robot Service is to provide an automatic tool to automate file transfer in a process pipeline using STATEL.
More informationHelp. Contents Back >>
Contents Back >> Customizing Opening the Control Panel Control Panel Features Tabs Control Panel Lists Control Panel Buttons Customizing Your Tools Pen and Airbrush Tabs 2D Mouse and 4D Mouse Tabs Customizing
More informationDAS202Tools v1.0.0 for DAS202 Operating Manual
DAS202Tools v1.0.0 for DAS202 Operating Manual DAT102Tools 1.0.0 Manual Table of context 2 Table of Contents 1 General Information... 3 2 PC... Configuration Requirements 3 3 Software Installation... 3
More informationSmart Board Notebook Software A guide for new Smart Board users
Smart Board Notebook Software A guide for new Smart Board users This guide will address the following tasks in Notebook: 1. Adding shapes, text, and pictures. 2. Searching the Gallery. 3. Arranging objects
More informationTutorial: 3D Pipe Junction Using Hexa Meshing
Tutorial: 3D Pipe Junction Using Hexa Meshing Introduction In this tutorial, you will generate a mesh for a three-dimensional pipe junction. After checking the quality of the first mesh, you will create
More informationSW43W. Users Manual. FlukeView Power Quality Analyzer Software Version 3.20 onwards
SW43W FlukeView Power Quality Analyzer Software Version 3.20 onwards Users Manual 4822 872 30778 December 2005, Rev.1, 04/06 2005 Fluke Corporation, All rights reserved. All product names are trademarks
More informationGOOGLE DOCS APPLICATION WORK WITH GOOGLE DOCUMENTS
GOOGLE DOCS APPLICATION WORK WITH GOOGLE DOCUMENTS Last Edited: 2012-07-09 1 Navigate the document interface... 4 Create and Name a new document... 5 Create a new Google document... 5 Name Google documents...
More informationQIAsymphony Management Console User Manual
April 2012 QIAsymphony Management Console User Manual For use with software version 4.0 Sample & Assay Technologies Trademarks QIAGEN, QIAsymphony, Rotor-Gene (QIAGEN Group). InstallShield (Informer Technologies,
More informationAVTS Advanced Visual Test Software, 3.3
, 3.3 AVTS Powerful, easy-to-use Microsoft Windows 2000/XP/Vista TM compatible Designed to manage all aspects of protective relay testing using the MPRT Relay Test Set Now loaded with more features and
More informationSchool of Electrical and Information Engineering. The Remote Laboratory System. Electrical and Information Engineering Project 2006.
School of Electrical and Information Engineering The Remote Laboratory System Electrical and Information Engineering Project 2006 By Ben Loud Project Number: Supervisors: 2006A Jan Machotka Zorica Nedic
More informationFoxit Enterprise Reader GPO User Guide
1 Copyright 2013 Foxit Corporation. All Rights Reserved. No part of this document can be reproduced, transferred, distributed or stored in any format without the prior written permission of Foxit. Anti-Grain
More informationTutorial: Configuring GOOSE in MiCOM S1 Studio 1. Requirements
Tutorial: Configuring GOOSE in MiCOM S1 Studio 1. Requirements - Two (2) MiCOM Px4x IEDs with Version 2 implementation of IEC 61850 - Two (2) Cat 5E Ethernet cable - An Ethernet switch 10/100 Mbps - MiCOM
More informationflexanalysis User Manual
flexanalysis User Manual Version 3.0 (September 2006) Copyright Copyright 2006 Bruker Daltonik GmbH This document is published by Bruker Daltonik Bremen. All rights reserved. Reproduction, adaptation or
More informationBrowsing and working with your files and folder is easy with Windows 7 s new look Windows Explorer.
Getting Started with Windows 7 In Windows 7, the desktop has been given an overhaul and makeover to introduce a clean new look. While the basic functionality remains the same, there are a few new navigation
More informationInstallation and Operation Manual Unite Log Analyser
Installation and Operation Manual Unite Log Analyser Contents 1 Introduction... 3 1.1 Abbreviations and Glossary... 4 2 Technical Solution... 4 2.1 Requirements... 5 2.1.1 Hardware... 5 2.1.2 Software...
More informationDDX 7000 & 8003. Digital Partial Discharge Detectors FEATURES APPLICATIONS
DDX 7000 & 8003 Digital Partial Discharge Detectors The HAEFELY HIPOTRONICS DDX Digital Partial Discharge Detector offers the high accuracy and flexibility of digital technology, plus the real-time display
More informationUser s Manual. Management Software for ATS
ATS Monitor User s Manual Management Software for ATS Table of Contents 1. ATS Monitor Overview... 2 2. ATS Monitor Install and Uninstall... 2 2.1. System Requirement... 2 2.2. Software Install... 2 2.3.
More informationFluidDraw 5 User s Guide
FluidDraw 5 User s Guide 04/08 FluidDraw is an application for creating pneumatic circuit diagrams. Not only the standard circuit symbols are available but also all of the components contained in the Festo
More informationCreating Hyperlinks & Buttons InDesign CS6
Creating Hyperlinks & Buttons Adobe DPS, InDesign CS6 1 Creating Hyperlinks & Buttons InDesign CS6 Hyperlinks panel overview You can create hyperlinks so that when you export to Adobe PDF or SWF in InDesign,
More informationGenerator Differential Relay Electrical Apparatus
Generator Differential Relay Electrical Apparatus MD3G Rotating Machine Differential Relay 150-3 The MD3G Rotating Machine Differential Relay is a member of Cooper Power Systems Edison line of microprocessor
More informationMouse and Pointer Settings. Technical Brief
Mouse and Pointer Settings Technical Brief Avocent, the Avocent logo, DSView, AutoView, SwitchView, DSR, OSCAR and AVWorks are trademarks or registered trademarks of Avocent Corporation or its affiliates.
More informationPowerLogic ION Enterprise 6.0
70002-0298-00 06/2009 PowerLogic ION Enterprise 6.0 Power management software User guide Notices This section describes the symbols used in this guide. Danger This alerts you to things that may cause
More informationSpecial Edition for FastTrack Software
08/14 The magazine for professional system and networkadministration Special Edition for FastTrack Software Tested: FastTrack Automation Studio www.it-administrator.com TESTS I FastTrack Automation Studio
More informationBefore You Start 1 Overview 2 Supported Devices 4 Public (User LAN) and Private (APC LAN) Networks 5. Initial Configuration Requirements 6
Contents Introduction 1 Before You Start 1 Overview 2 Supported Devices 4 Public (User LAN) and Private (APC LAN) Networks 5 Initial Configuration Requirements 6 Overview 6 Setup Wizard 7 Status, Alarm,
More informationDataPA OpenAnalytics End User Training
DataPA OpenAnalytics End User Training DataPA End User Training Lesson 1 Course Overview DataPA Chapter 1 Course Overview Introduction This course covers the skills required to use DataPA OpenAnalytics
More informationComputer Controlled Generating Stations Control and Regulation Simulator, with SCADA SCE
Technical Teaching Equipment Computer Controlled Generating Stations Control and Regulation Simulator, with SCADA SCE EDIBON SCADA System Teaching Technique used 4 5 2 Data Acquisition Board Cables and
More informationISIO 200. Binary Input/Output (I/O) Terminal with IEC 61850 Interface
ISIO 200 Binary Input/Output (I/O) Terminal with IEC 61850 Interface Compact and Easy ISIO 200 Put your Binary I/Os where you need them ISIO 200 is a simple and versatile binary I/O terminal with IEC 61850
More informationTraining Document for SIMIT SCE. MODULE G2 'Startup System Simulation with SIMIT SCE V7
Training Document for SIMIT SCE MODULE G2 Training Document for SIMIT SCE Page 1 ofn 39 Module G2 Status December 2009 Trademark SIMIT is a trademark of Siemens AG. The other names in this document may
More informationGuide To Creating Academic Posters Using Microsoft PowerPoint 2010
Guide To Creating Academic Posters Using Microsoft PowerPoint 2010 INFORMATION SERVICES Version 3.0 July 2011 Table of Contents Section 1 - Introduction... 1 Section 2 - Initial Preparation... 2 2.1 Overall
More informationLinkage 3.2. User s Guide
Linkage 3.2 User s Guide David Rector Wednesday, April 06, 2016 Table of Contents Table of Contents... 2 Installation... 3 Running the Linkage Program... 3 Simple Mechanism Tutorial... 5 Mouse Operations...
More informationManual for simulation of EB processing. Software ModeRTL
1 Manual for simulation of EB processing Software ModeRTL How to get results. Software ModeRTL. Software ModeRTL consists of five thematic modules and service blocks. (See Fig.1). Analytic module is intended
More informationPowerWorld Simulator
PowerWorld Simulator Quick Start Guide 2001 South First Street Champaign, Illinois 61820 +1 (217) 384.6330 support@powerworld.com http://www.powerworld.com Purpose This quick start guide is intended to
More informationPBA.pro Getting Started
PBA.pro Getting Started Issue 01.04 May 2007 AIM GmbH Sasbacherstr. 2 79111 Freiburg Germany www.aim-online.com Page 1 of 18 Table of Contents Table of Contents... 2 General... 3 PBA.pro Configuration...
More information