Implementing Performance Based Maintenance, Saving Energy and Improving Uptime



Similar documents
Field Device Strategies for Sustainability

XYZ Biotech Case Study: Reducing Cost and Improving Uptime for Air Handler System October 2008

What is a successful Steam Trap Management Program?

Proactive Monitoring of Friction Management Systems Reduces Costs and Downtime

Compliance, Risk and Cost of Ownership Comparisons for Pharmaceutical Continuous Monitoring Wired, Wireless and Standalone Monitoring Systems

Increase data center uptime while decreasing costs. Why not have it all? DData Center Building Management Solutions

SJÖGREN S INTERNATIONAL COLLABORATIVE CLINICAL ALLIANCE (SICCA) BIOREPOSITORY AND DATA REGISTRY STORAGE OF BIOSPECIMENS

ESP 20/20. Compressor Monitoring System

Increase data center uptime while decreasing costs. Why not have it all? Data Center Building Management Solutions

Retrofitting Existing Buildings for V5.0

Web Service. User Manual

The 101 of Smart Metering - Easier and harder than you think Guenter Hauber-Davidson, Water Conservation Group

Equipment Performance Monitoring

PARTNERING. in Energy. Solutions A PROGRAM TO PROMOTE BUSINESS ENERGY EFFICIENCY

Rajesh Kaza. Leadership Seminar. Technology to Enhance Operations and Maintenance Synergy

HELIUM PULSE FOR MONITORING AND ALERTING HELIUM SMART SENSORS HELIUM NETWORK HELIUM CLOUD HELIUM PULSE HP

Sensor Monitoring and Remote Technologies 9 Voyager St, Linbro Park, Johannesburg Tel: ;

PARTNERING. in Energy. Solutions A PROGRAM TO PROMOTE BUSINESS ENERGY EFFICIENCY

High Availability for Non-Traditional Discrete and Process Applications Ensuring Continuous Operations With Increased Controller Reliability

DTC B1423/23 Pressure Sensor Circuit

MAXIMIZING YOUR DATA CENTER INFRASTRUCTURE: CENTRALIZED MANAGEMENT AND WIRE-FREE ENVIRONMENTAL MONITORING

Air Conditioning Sign-Off Sheet

Managed IT Services:

Welcome. Wireless Water Leak Detection & Monitoring For HOAs

Choosing the Right Industrial Wireless Network

Ultrasound Condition Monitoring

Statement of Work. 3.0 Details of Service Pre Start-up Cooling Start-up Service. Installation Service. Table of Contents. 1.0 Executive Summary

How To Get The Most Out Of Your Data Center Service From Liebert

Managed Services. Enhance Profitability Mitigate Risk

NIL MONITOR ADD VALUE TO YOUR IT INFRASTRUCTURE

Bosch Rexroth. The Drive & Control Company

Building tomorrow s solutions.

AEP Ohio Business Incentives for Energy Efficiency. Topics. Why Energy Efficiency? 11/24/2014. Economic Development 101 November 21, 2014

Your Guide to Buying an Energy-Efficient Central Air Conditioner

Enterprise Remote Monitoring

Condition Based Monitoring Program Compressed Air Energy Savings Program

Take Control of Costs

Foreseer Services. Product application guide. Table of contents

Communicating the Value of Energy Efficiency Projects to Financial Decision Makers in Not-For-Profit Markets

Modular Chiller Plants for data centers. Downtime isn t acceptable

Site Preparation Management Co., Ltd. March 1st 2013 By Nara Nonnapha, ATD UPTIME

Advanced Fire Protection in Data Centres

Retrofitting Existing Buildings for Demand Response & Energy Efficiency

SERVICE MANUAL REFRIGERATION

.5.1 MAINTENANCE AND PERIODIC INSPECTION OF DRAINAGE SYSTEMS

IT Services Performance Report

Wireless Sensor Networks

Comprehensive Solutions for Data Centers. Rely on Siemens for maximum uptime, reliability, and efficiency.

VISTA Operations Management Systems COMPLETE SECURITY SOLUTIONS FOR ANY RETAIL BUSINESS. Value Beyond Security

Solutions informatiques

The Application of Circuit Breakers to Reduce Downtime in Datacentres

Affordable wireless monitoring without compromise

Proactive Network Performance Monitoring

Fleet Telematics Solution

Overview. Components of an alarm system Technology behind the equipment Communication Platforms Industry Terminology False Alarm Tips DSC products

Contingency Planning Minimizing risk when the unexpected happens

Break Free. from non-productivity & revenue loss with InSite *

IntraVUE Diagnostics. Device Failure

Wired versus wireless trade-offs

Supporting Service Solutions

Executive Summary WHAT IS DRIVING THE PUSH FOR HIGH AVAILABILITY?

Seven Things Critical Facilities Managers Need to Know About Wirefree Monitoring

Wireless Systems. Make Non-traditional Measurements Possible

Meeting the Challenge of Pipeline Emergency Repair

Predictive Maintenance in a Mission Critical Environment

emobility WAGO Leading the Charge

Energy efficiency and cost reduction solutions for industry. PowerLogic application brochure

MINNESOTA WEST COMMUNITY & TECHNICAL COLLEGE COURSE OUTLINE

THE TOWN OF GROTON IS REQUESTING PROPOSALS FOR A WIRELESS ALARM MONITORING AND CONTROL SYSTEM WITH INTERNET BASED DATA ACCESS

THE CASE FOR A REFRIGERATION PREVENTATIVE MAINTENACE PROGRAM

Business Checklist for Severe Weather

Data Centers That Deliver Better Results. Bring Your Building Together

Asset management systems increase reliability and efficiency

UBC Social Ecological Economic Development Studies (SEEDS) Student Report. Project on server room management. Yu Chen Wang, Auburn Leung

Liebert Data Center Services. Services For Business-Critical Continuity

Integrated Wire-Free Solution for Monitoring Power and Environment with RF Code and Sentry Power Manager (SPM)

DEVELOPING A CORPORATE WATER MANAGEMENT STRATEGY

Wireless Temperature Monitoring System SCHOOLS K-12 / UNIVERSITIES HOTELS / CASINOS / RESORTS QUICK-SERVE RESTAURANTS MAINTENANCE / FACILITIES

Monitoring the Computer Room s Physical Environment A white paper from Sensaphone, Inc.

Model: 400E-2M. Bermad Electrically Controlled Deluge Valve with Easy Lock Manual Reset. Installation Operation Maintenance. Application Engineering

NuRON Water Network Monitoring. Detect problems in real time before they turn into headaches

SYSTEMS APPLICATIONS DIVISION INDUSTRY SOLUTIONS

DEFROSTING. Service Engineers Section Technical Bulletin No 3

Smart. Scalable. Simple.

Business Continuity: Choosing the Right Technology Solution

The Residence Hall Security System That So You Don't Have To.

MANAGEMENT AND USE OF WORK EQUIPMENT: PRESSURE SYSTEMS

Optimization of Gas Field Operations with Field Automation Software

The Importance of Software License Server Monitoring White Paper

Remote Pressure Monitoring System* Reduce water main breaks and customer complaints

1. What percent of a commercial business s energy usage comes from their HVAC system? A. 13% B. 23% C. 33% D. 43% E. 53%

EXTENDED 10 YEAR LIMITED LIFETIME WARRANTY LIMITED LIFETIME WARRANTY

Smart Monitoring Service

A Quick Primer on Data Center Tier Classifications

Network Management and Monitoring Software

Energy Savings in the Data Center Starts with Power Monitoring

Other Innovative Mueller Products

TracKing. A complete web-enabled temperature management system.

IceSpy Mini System. Makes light work of small to medium wireless environmental monitoring FOOD INDUSTRY SPECIFIC PRODUCT SOLUTIONS

FLUXUS Energy. Manage energy effectively using non-invasive measuring technology. Heat usage, chilled flows and compressed air flow rate

Transcription:

Implementing Performance Based Maintenance, Saving Energy and Improving Uptime Chris Stubbs, Senior Director, Corporate Facilities Services Genentech, March 2009 Summary Genentech s focus on implementing a performance-based monitoring strategy led the company to a non-invasive wireless monitoring solution. By implementing the solution on steam traps and critical research equipment, Genentech was able to improve its asset management strategy, find energy savings and improve uptime. Background Genentech s mission is to meet unmet medical needs. One of the goals in the Corporate Facilities Services group is to operate a world class facility. The key focus area to achieve this goal is continuous improvement of facilities and maintenance systems to reduce operating costs. By driving down operating costs, more funds can be allocated to developing the product pipeline and achieving the mission. The guiding principles for identifying and executing continuous improvement projects include: Improving plant asset management by implementing a performance-based maintenance strategy. Genentech has a well-established time-based asset maintenance program. Transitioning to a performance-based strategy will also allow Genentech to predict equipment failure and understand an asset s life cycle. Reducing energy costs. Identifying methods to improve the efficiency of energy consumption will reduce energy costs and improve the bottom line. Improving uptime. Research and operations expect the facility and equipment to be functional and reliable. Any downtime in the facility directly impacts the bottom line. Corporate Facilities Services focuses on improving uptime and equipment reliability to help achieve the mission. Genentech identified several assets that could benefit from a performance-based maintenance strategy in order to reduce energy costs or to improve uptime. Page 1

Steam Traps. Genentech has an annual steam trap maintenance program. However, throughout the year, steam traps often fail. Steam loss from failed traps was estimated to cost the company hundreds of thousands of dollars annually. Steam trap failures could be prevented or found as they occur using a steam trap monitoring system, resulting in significant energy savings. Critical Research Equipment. Ultra-low freezers are critical to research activities. Reliability issues with older stand-alone freezers result in downtime and potential loss of work product. Maintenance activities are performed more frequently to avoid these issues. Performance-based monitoring of these research freezers would allow the maintenance staff to proactively detect issues and prevent failures. This would result in increased freezer uptime and could potentially extend the useful life of the freezers. The challenges with implementing performance-based maintenance on existing systems include cost and invasiveness. In order to monitor the condition of assets, analog instruments must be replaced or new instruments must be installed to collect data. Traditionally, this work is invasive and requires a process interruption and engineering oversight. Furthermore, the new system must be commissioned for restart. This often includes inspections and leak checks, as well as revalidation in order to return the system to service. These activities often result in an unfavorable cost/benefit ratio. As a cost effective alternative, Genentech identified a non-invasive monitoring solution, provided by Cypress Envirosystems. Devices are clamped onto existing instrumentation to collect and wirelessly transmit data to a server for trending and alarming. This method eliminates the need for process interruption for installation and minimizes engineering oversight. Table 1 below shows the comparison of monitoring solutions. Table 1. Traditional Monitoring versus Non-Invasive Wireless Monitoring Solution Plant Disruption Reliability Engineering Infrastructure Traditional Monitoring Invasive Process interruption required Wiring required Power source required Real-time data collection Changes existing system May require engineering change management System re-commissioning required for restart May require new software Non-Invasive Wireless Monitoring Non-invasive, clamp-on devices No process interruption Minimal wiring Battery operated Pre-programmed data collection rate No changes to existing system Minimal engineering change management No system restart required Interface available for integration into existing infrastructure Cost $3,000 - $5,000 per point $750 - $1,500 per point Page 2

Genentech was concerned about the viability of a new wireless technology in the facility. Although the traditional monitoring solution was more challenging to implement, it was a technology that was commonly used on campus. With the non-invasive wireless solution, there were concerns with data integrity, wireless security, and data integration into the existing infrastructure. To demonstrate proof of concept, as well as to quantify potential savings, Genentech partnered with Cypress Envirosystems to pilot this technology on specific equipment. Results Steam Traps Wireless Steam Trap Monitors (WSTMs) were installed on 56 steam traps at a cost of $42,000. The WSTMs were intended to provide early indication of steam leakage or blockage, which lead to failure. Data was collected on a blue box server for trending analysis. Fourteen steam traps showed signs of failure. The maintenance team investigated and the traps were replaced. Early detection saved an estimated $53,000 in annual steam loss. The project payback was 10 months. Critical Research Equipment Wireless Freezer Monitors (WFMs) were installed on 20 critical freezers at a cost of $20,000. The WFMs measured parameters including low-stage and high-stage compressor amperage, internal chamber temperature, and door open/close status. The data collected was intended to provide early indication of refrigerant leaks or door seal issues, which lead to freezer failures. Four freezers showed signs of distress. Sample data trends are shown in Figures 1-3. Even though the temperature profiles of the freezers showed no problems with freezer functionality, the compressor amperage profiles indicated that freezer failure was imminent. The issues were investigated and resolved by the maintenance team without having to replace the freezers. Early detection saved an estimated $20,000 in replacement costs. Furthermore, Corporate Facilities Services repaired the freezers before they failed and minimized the risk of losing any research samples, thus protecting the product pipeline. The project payback was immediate. Page 3

Figure 1. Freezer Compressor Amperage Data Trend This graph shows low stage compressor amperage over time for two freezers. The profile of the abnormal freezer indicates a potential refrigerant leak. Figure 2. Freezer Compressor Amperage Data Trend This graph shows high stage compressor amperage over time for two freezers. The profile of the abnormal freezer indicates an electrical problem with the compressor. Figure 3. Freezer Temperature Data Trend This graph shows temperature over time for two freezers. The profile of the abnormal freezer indicates a potential door seal problem. Page 4

Conclusion The pilot projects demonstrated that the non-invasive wireless monitoring solution was a successful tool in implementing a performance-based maintenance strategy. Installation of the non-invasive wireless monitoring solution did not disrupt plant operations. There were no issues found with wireless security. The data collected was easily integrated into Genentech s existing infrastructure. The overall results showed a payback period of less than one year. Page 5