QuickSpecs. HP R/T3000 G2 Uninterruptible Power System (UPS) Overview



Similar documents
HP R/T3000 G2 Uninterruptible Power System (UPS) Overview

R5000 Uninterruptible Power System (UPS) Overview

R5000 Uninterruptible Power System (UPS) Overview

QuickSpecs. Models HP T1500 UPS JPN/TWN. HP UPS T1000 G2, T1500 G2 Models Overview

QuickSpecs. HP 480/277 Volt Solutions. Overview

How To Upgrade An Hp Power Distribution Rack To A Power Distribution Unit

QuickSpecs. HP Fixed Cord PDUs & Extension Bars (Zero-U/1U Modular PDUs) Overview

QuickSpecs. What's New HP 3TB 6G SAS 7.2K 3.5-inch Midline Hard Drive. HP SAS Enterprise and SAS Midline Hard Drives. Overview

QuickSpecs. What's New HP 1.2TB 6G SAS 10K rpm SFF (2.5-inch) SC Enterprise 3yr Warranty Hard Drive

QuickSpecs. HP Managed Power Distribution Units (mapdu) Overview

HP Server Console Switch with Virtual Media Overview

QuickSpecs. HP Modular Power Distribution Units (Zero-U/1U Modular PDUs) Overview

QuickSpecs. Models HP Server Console Switches

QuickSpecs. Overview. HP Power Distribution Rack. HP Power Distribution Rack. DA North America Version 5 August 22, 2008 Page 1

QuickSpecs. HP SATA Hard Drives. Overview

HP UPS Management Module Overview

QuickSpecs. HP IP Console Switch with Virtual Media Overview

QuickSpecs. HP SATA Hard Drives. Overview

HP PDU Management Module Overview

QuickSpecs. Models. HP UPS Management Module. HP UPS Management Module. Overview

QuickSpecs. What's New Updating list of supported servers. HP Half-Height SATA DVD RW Optical Drive. Overview

HP Solid State Drive (SSD) Overview

HP Common Slot Power Supplies Overview

QuickSpecs. Models HP QMH Gb Fibre Channel Host Bus Adapter B21. HP QMH Gb FC HBA for BladeSystem c-class.

QuickSpecs. HP SATA Hard Drives. Overview

QuickSpecs HP TFT7600 G2 KVM Console and Monitor (TFT7600 G2)

QuickSpecs. Models HP Server Console G2 Switch. HP Server Console Switch G2 with Virtual Media & CAC. Overview

HP rack and power infrastructure products are designed and developed to be used specifically with HP servers and storage.

QuickSpecs. HP Remote Monitored Power Distribution Units (mpdu) Overview

The DVD ROM drive is designed to read not only CD ROM and CD R/RW discs but also DVD ROM, DVD RAM, DVD +R/RW and DVD R/RW discs.

QuickSpecs. Compaq Uninterruptible Power Systems M ODELS

HP Common Slot Power Supplies Overview

HP 9.5mm SATA DVD RW Optical Drive

HP DDR4 SmartMemory Is finding reliable DRAM memory for your HP ProLiant Server series in your data center a major challenge?

Model #: SMART2200CRMXL

QuickSpecs. Models. HP Dynamic Smart Array B320i Controller. Overview

SmartOnline V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial

Model #: SMART2200VS. 2200VA / 2.2kVA line interactive tower UPS. Maintains 120V nominal output over an input range of 79 to 147V

QuickSpecs. HP IP Console Switches. Overview

SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications

SmartOnline V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire

SmartPro 120V 500VA 300W Line-Interactive UPS, SNMP, Webcard, 1U Rack/Tower, USB, DB9 Serial

HP UPS R1500 Generation 3

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

Uninterruptible Power Supply

Smart Pro Rack/Tower UPS Intelligent, line interactive network power management system

SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Extended Run, SNMP, Webcard, Tower, USB, DB9 Serial

QuickSpecs. HP Solid State Drives (SSD) What's New. HP Solid State Drives (SSD) Overview

TAA-Compliant SmartPro 120V 1kVA.8kW Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack-Mount, USB, DB9 Serial

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 1U Rackmount, SNMPWEBCARD Option, USB, DB9 Serial

QuickSpecs. Models. HP StorageWorks X510 3TB Data Vault. HP StorageWorks X500 Data Vault. HP StorageWorks X500 Data Vault.

You have more pressing concerns than how to backup and share your data but you know it needs to be done and you know it would benefit your business.

HP 8GB MicroSD Enterprise Performance Flash Media Kit

QuickSpecs. HP SAS Enterprise and SAS Midline Hard Drives Overview

QuickSpecs. HP NC552SFP 10Gb 2-port Ethernet Server Adapter. HP NC552SFP 10Gb 2-port Ethernet Server Adapter. Overview

Audio/Video AVR Series UPS - Intelligent Automatic Voltage Regulated Power Management System

AIS 3000 APC AIS kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass

Liebert GXT3 Reliable On-Line UPS Protection In A Compact 2U Package 700VA -3000VA

SmartPro 230V 750VA 500W Line-Interactive Sine Wave UPS, SNMP, Webcard, Tower, USB, DB9 Serial

QuickSpecs. What's New HP 8GB USB Enterprise Mainstream Flash Media Drive Key Kit. HP Flash Media Kits. Overview

HP ProLiant Lights-Out 100c Remote Management Cards Overview

PowerGem Pro Uninterruptible Power Supply

QuickSpecs. HP Serial-ATA (SATA) Entry (ETY) and Midline (MDL) Hard Drive Option Kits. Overview

HP Hardware Support Onsite 6-Hour Call-to-Repair Service - U.S.

QuickSpecs. HP Virtual Desktop Infrastructure with VMware Overview

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Smart-UPS APC Smart-UPS 1000VA USB & Serial 230V

QuickSpecs. Models. HP ProLiant Lights-Out 100c Remote Management Cards Overview

OmniVS Series 1500VA Line-Interactive Tower 120V UPS with USB port

For protection from laptops to high availability facilities - and everything in between - APC is a partner you can count on

Industrial Tower Uninterruptible Power Supply Specifications Bulletin Numbers 1609-P

SmartPro 100/110/120V 1.5kVA 900W Line-Interactive Sine Wave UPS, Tower, SNMP, Webcard, USB, DB9 Serial

BC Pro UPS System Standby UPS System

3U, 2200 VA Audio/Video Pure Sine Wave UPS System

Product Snapshot. Powerware 5125 Family Uninterruptible Power System. Introducing the expanded Powerware 5125 family of UPSs.

Models Smart Array 6402A/128 Controller 3X-KZPEC-BF Smart Array 6404A/256 two 2 channel Controllers

QuickSpecs. HP Smart Array 5312 Controller. Overview

Liebert GXT MT+ CX UPS, 1000VA VA Intelligent, Reliable UPS Protection. AC Power for Business-Critical Continuity

It is also available as part of the HP IS DVD and the Management DVD/HPSIM install.

HP Hardware Support Onsite 6-Hour Call-to-Repair Service - U.S.

You have more pressing concerns than how to backup and share your data but you know it needs to be done and you know it would benefit your business.

SmartPro 230V 1000VA 900W Line-Interactive Sine Wave UPS, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial

HP Smart Array 5i Plus Controller and Battery Backed Write Cache (BBWC) Enabler

How To Power A Power Supply Shelf With A Power Unit (Hp 2920)

QuickSpecs. HP Dynamic Smart Array Controllers. Models HP Dynamic Smart Array RAID Controllers. HP Dynamic Smart Array Controllers.

Smart-UPS On-Line 230 V

QuickSpecs. Models. HP StorageWorks Modular Smart Array 50 Enclosure. HP StorageWorks Modular Smart Array 50 Enclosure. Overview

Transcription:

Overview The industry leading packs up to 3000 watts into a space saving 2U design. Proven Digital Signal Processor (DSP) double conversion system provides clean, reliable power protection in an energy efficient transformer-less design while reducing generated heat. The HP R/T3000 G2 UPS includes a Rack to Tower Conversion Kit for non rack applications outside the data center. In this configuration the HP R/T3000 G2 can provide powerful protection to multiple tower servers as well as tower Blade Enclosures such as the HP BladeSystem c3000 Enclosure. In addition, Extended Runtime Modules (ERM) are available to increase battery run time during a power outage. ERMs can be used in both rack mount and tower configuration with the HP R/T3000 G2UPS. Robust and Flexible UPS management is provided by HP's New Power Protector UPS Management software. R/T3000 Rackmount UPS configuration 1. Front bezel - battery compartment behind bezel 3. Power control buttons 2. Status LED indicators DA - 14058 Worldwide Version 2 July 20, 2011 Page 1

Overview R/T3000 Tower UPS configuration with optional Extended Runtime Module 1. Optional Extended Runtime Module 3. Tower UPS floor stands 2. R/T3000 in Tower UPS configuration Models HP R/T3000 G2 2U L530 Low Voltage NA/JP Uninterruptible Power System HP R/T3000 G2 2U L620 High Voltage NA/JP Uninterruptible Power System HP R/T3000 G2 2U Detachable Cord High Voltage INTL Uninterruptible Power System AF466A AF467A AF468A DA - 14058 Worldwide Version 2 July 20, 2011 Page 2

Standard Features Key Features New convertible design can be used as a 2U rack mountable UPS or as a standalone tower UPS Increased power density with up to 3300VA / 3000 Watts (200-240V models) Greater system uptime with support for up to two Extended Runtime Modules (ERM) Easy configuration through enhanced front panel display Enterprise-wide intelligent manageability with bundled power management software Support for the HP UPS Network Module that extends the power management capabilities of the UPS More efficient voltage regulation using digital signal processing technology Ultimate long-term battery reliability with HP Enhanced Battery Management Enhanced system flexibility with two independently controlled load segments Support for Remote Emergency Power Off (REPO) circuitry Easy serviceability through modular design Hot-Swappable Batteries Backed by a three year warranty with the first year including parts and labor. HP's Pre-Failure warranty, and a $250,000 load protection guarantee*. (Certain restrictions and exclusions apply; *Load protection guarantee available in North America only.) Optional upgrades include: Extended Runtime Modules (ERMs) Management Cards New Convertible Design The R/T3000 G2 can be used in a traditional rack mount environment or converted to a Tower UPS to support powerful Tower servers even Tower Blade Servers such as the HP c3000 BladeSystem. 2U Power Packed Design Rated near unity at 3300VA / 3000W (200-240V models), the HP UPS R/T3000 G2 packs more power in space-conserving rack-mount design, allowing you to support more critical equipment in your rack. Increase System Uptime with Extended Runtime Modules The Extended Runtime Modules are external battery modules that occupy 2U (3.5 inches) of rack space each. The HP UPS R/T3000 G2 supports up to two Extended Runtime Modules (ERM), in either rack mount or tower configuration, which extend your overall battery runtime. Lower Cost of Ownership with Innovative Technology The HP UPS R/T3000 G2 utilizes a new industry-leading technology that continually conditions and regulates power without using the battery, thereby increasing the life of the battery. The output voltage is automatically regulated, based on the connected load and the input voltage. Investment Protection with HP Enhanced Battery Management HP UPS R/T3000 G2 incorporates Enhanced Battery Management: an exclusive, patented technology that doubles battery service life, optimizes battery recharge time, and provides advance notice of pending battery failure. With Enhanced Battery Management, you have a lower total cost of ownership and receive the best in the industry protection for your critical equipment. Enhanced Flexibility The high voltage R/T3000 UPS include one PDU Extension Bar. The extension bar has seven C13 outlets for powering equipment in the rack and attaches to the C19 outlets on the back of the UPS. The 6.5 foot (2 meter) cord allows the extension bar to be mounted in many locations inside the rear of the rack. DA - 14058 Worldwide Version 2 July 20, 2011 Page 3

Standard Features Remotely Monitor UPSs on The optional HP UPS UPS Module features the ability to perform simultaneous network and out-of-band the Network communications. It enables network administrators to remotely monitor UPSs and reboot network devices. It provides SNMP functionality, including power event alerts, network power diagnostics, and remote UPS reboot and testing. Used in conjunction with HP Systems Insight Manager or other SNMP capable Network Management Software, power-related problems on the network are quickly discovered and remedied. Enhanced Front Panel Display LED and switch membrane integrated into the front panel with power controls and status and load indicators for easy visibility. HP R/T3000 UPS Front Panel 1. Dual function LED: Self Test and load indicator (10% load) 7. Power on button 2. Dual function LED: Battery fault and Load Indicator (25% 8. Power off button load) 3. Dual function LED: Site wiring fault and load indicator (50% 9. Test/Alarm reset button load) 4. Dual function LED: Over Temperature and load indicator 10. On bypass indicator (75% load) 5. Dual function LED: Overload and load indicator (100%) 11. On battery indicator 6. Start on battery button 12. Utility power indicator DA - 14058 Worldwide Version 2 July 20, 2011 Page 4

Standard Features Intelligent Manageability HP Power Protector management software included with the R1500 G3 models. The HP Power Protector Software enables you to monitor and control an HP UPS locally or remotely. This software is a versatile, fully configurable, alert response tool that gives system administrators a full overview of the UPS's conditions. It enables you to monitor system status and power conditions, configure shut down timing, customize alert messages, and gracefully shut down servers during an extended power outage. For more information on HP Power Protector software please see: www.hp.com/go/hppp Independently Controllable Load Segments With two independent controlled load segments, you have the flexibility to configure each segment's shut down schedule to maximize runtime for critical equipment. Ease of Maintenance with Hot-Swappable Batteries The UPS R/T3000 G2 is designed with simple access through the front panel for hot swappable batteries. Users can safely install new batteries without ever powering down connected server and server options. HP Quality HP's hardware qualification is the toughest in the industry. Extensive evaluation, testing, product improvement, and an unsurpassed warranty guarantee the highest level of system protection, electrical performance, product quality and compatibility. Compatibility Compatible with all HP servers, storage, racks, rack options, and other rack mountable HP equipment (for PDU options please refer to the UPS/PDU compatibility matrix on http://www.hp.com/ups). Warranty The HP UPS R/T3000 G2 is covered by a three year warranty, with the first year including parts and labor. Also, standard on all HP UPS units, is our exclusive Battery Pre-Failure Warning, which extends the advantage of a HP three-year, limited warranty by applying it to the battery before it actually fails. This warranty is offered worldwide. Specifically, the Battery Pre-Failure Warning ensures that when customers receive notification from HP Power Management Software that the battery may fail, the battery is replaced free of charge under the warranty. NOTE: $250,000 Computer/Load Protection Guarantee is also provided in North America, in addition to the HP three year, limited warranty. DA - 14058 Worldwide Version 2 July 20, 2011 Page 5

Service and Support Service and Support HP Technology Services HP Technology Services offers you consultants and support experts to solve your most complex infrastructure problems. We help keep your business running, boost availability and avoid downtime. Protect your business beyond warranty with HP Care Pack Services When you buy HP Options, it's also a good time to think about what level of service you may need. HP Care Pack services provide total care and support expertise with committed response choices designed to meet your IT and business need. Recommended HP Care Pack Services for optimal satisfaction with your HP product Recommended Services 3-Year HP 24x7 4 hour Response, Hardware Support Onsite Service Provides you with rapid remote support and if required an HP authorized representative who will arrive on site any time and day of the year to begin hardware maintenance service within 4 hours of the service request being logged. http://h20195.www2.hp.com/v2/getpdf.aspx/5982-6547eee HP ProLiant Server Hardware Installation Provides for the basic hardware installation of HP branded servers, storage devices and networking options to assist you in bringing your new hardware into operation in a timely and professional manner http://h20195.www2.hp.com/v2/getpdf.aspx/5981-9356en Related HP Care Pack Services to enhance your HP product experience Related Services 3-Year HP 6 hour Hardware Support Onsite Call-to-Repair Service Provides an IT manager with a team of support specialists who will quickly begin troubleshooting the system to help return the hardware to operating condition within 6 hours of the initial service request to the HP Global Solution Center http://h20195.www2.hp.com/v2/getpdf.aspx/5981-6636enn HP Proactive Select Service Provides a flexible way to purchase HP best-in-class consultancy and technical services. You can buy Proactive Select Service Credits when you purchase your hardware and then use the credits over the next 12 months. http://h20195.www2.hp.com/v2/getpdf.aspx/4aa2-3842enn Insight Remote Support Delivers secure remote monitoring and support for HP servers and storage, 24x7 at no additional cost. Available as part of HP Warranty, Care Pack and Service Contract offers. Parts and materials HP will provide HP-supported replacement parts and materials necessary to maintain the covered hardware product in operating condition, including parts and materials for available and recommended engineering improvements. Supplies and consumable parts will not be provided as part of this service; standard warranty terms and conditions apply. Parts and components that have exceeded their maximum supported lifetime and/or the maximum usage limitations as set forth in the manufacturer's operating manual or the technical product data sheet will not be provided, repaired or replaced as part of this service. Coverage For ProLiant servers and storage systems, this service covers HP-branded hardware options qualified for the server, purchased at the same time or afterward, internal to the enclosure, as well as external monitors up to 22" and tower UPS products; these items will be covered at the same service level and for the same coverage period as the server unless the maximum supported lifetime and/or the maximum usage limitation has been exceeded. Coverage of the UPS battery is not included; standard warranty DA - 14058 Worldwide Version 2 July 20, 2011 Page 6

Service and Support terms and conditions apply. The defective media retention service feature option applies only to Disk or eligible SSD/Flash Drives replaced by HP due to malfunction. It does not apply to any exchange of Disk or SSD/Flash Drives that have not failed. SSD/Flash Drives that are specified by HP as consumable parts and/or that have exceeded maximum supported lifetime and/or the maximum usage limit as set forth in the manufacturer's operating manual or the technical data sheet are not eligible for the defective media retention service feature option. For more information To learn more on services for HP ESSN Options, please contact your HP sales representative or HP Authorized Channel Partner. Or visit: http://www.hp.com/services/proliant or www.hp.com/services/bladesystem DA - 14058 Worldwide Version 2 July 20, 2011 Page 7

Innovative Options to Meet Your Data Center Needs Optional UPS Network Module The HP UPS Network Module enables you to monitor and manage power environments through comprehensive control of HP UPSs. The HP UPS Management Module can support either a single UPS configuration or provide additional power protection with support for dual redundant UPS configuration for no-single-point-of-failure. The additional serial ports will provide greater power management control and flexible monitoring. The management module can be configured to send alert traps to HP Systems Insight Manager and other SNMP management programs or used as a standalone management system. This flexibility enables you to monitor and manage UPSs through the network. To facilitate day-to-day maintenance tasks, the embedded management software provides detailed system logs. The HP UPS Network Module provides remote management of a UPS by connecting the UPS directly to the network. Configuration & Management of the UPS from anywhere and at anytime via a standard web browser. NOTE: For more information on the UPS Network Module please see: www.hp.com/go/hpunm. Extended Runtime Module The UPS R/T3000 G2 supports up to two Extended Runtime Modules. Each module is a 2U (3.5 inches), (ERM) rack mountable battery module that extends your overall battery runtime. Rack to Tower Conversion The included HP R/T3000 G2 UPS Tower Conversion Kit allows you to use the powerful R/T3000 G2 in Kit a tower configuration for your most powerful tower Servers or Blade Enclosures. The kit contains stabilizing feet and appropriate hardware for a fast, easy form factor change. Each Tower Conversion Kit can support one UPS and up to two Extended Runtime Modules. DA - 14058 Worldwide Version 2 July 20, 2011 Page 8

Related Options Extended Runtime Module HP R/T3000 Extended Runtime Module AF455A UPS Management HP UPS Network Module AF465A HP Care Pack HP Install Universal Power Supply 3KVA to Below 6KVA Service U4693E DA - 14058 Worldwide Version 2 July 20, 2011 Page 9

Model Matrix UPS Models Part Number AF466A Low Voltage (NA/JPN) AF467A High Voltage (NA/JPN AF468A (International) 1 Factory default setting. 2 LS1 = Load Segment 1 3 LS2 = Load Segment 2 Kit Contents Operating Voltage Settings 100, 110, 120, 127 200/208 1, Actual output voltage 204VAC Power Out Input Connection Output Connection (VA/Watts) 2880/2700 L5-30P, 3m cord LS1 2 : 2x NEMA 5-20 outlets, 1 x NEMA L5-30R LS2 3 : 2x NEMA 5-20 outlets 3300/3000 L6-20P, 3m cord LS1 2 : 3x IEC C13, 1x IEC C-19, 1x NEMA L6-20R LS2 3 : 3x IEC C13, 1x IEC C-19 NOTE: Includes one PDU Extension Bar. Each Extension Bar has 7x C13 outlets and plugs into a C-19 on the rear of the UPS. 220, 230, 240 3300/3000 Detachable IEC C-20 inlet plug LS1 2 : 3x IEC C13, 1x IEC C-19 LS2 3 : 3x IEC C13, 1x IEC C-19 NOTE: Includes one PDU Extension Bar. Each Extension Bar has 7x C13 outlets and plugs into a C-19 on the rear of the UPS. HP UPS R/T3000 G2 Power Products Documentation CD Depth adjustable fixed rack mounting rails, mounting brackets, cord retention clips Rack to Tower Conversion Kit and floor stand Communications cables AF453A and AF454A also includes 1 PDU Extension Bar (7 x C13 outlets each) DA - 14058 Worldwide Version 2 July 20, 2011 Page 10

Estimated Backup Times Chart (Minutes) Low Voltage NA/JPN model (2880VA / 2700 Watt) Load (Percent*) Estimates battery runtime (Minutes) With One Extended Runtime Module (Minutes) With Two Extended Runtime Modules (Minutes) 540W (20%) 45 142 256 1350W (50%) 15 55 99 2160W (80%) 7 34 60 2700W (100%) 5 26 47 NOTE: Backup times are estimated for typical applications. Actual performance will depend on load and battery conditions. High Voltage NA/JPN and Int'l model (3300VA / 3000 Watt) Load (Percent*) Estimated battery runtime (Minutes) With One Extended Runtime Module (Minutes) With Two Extended Runtime Modules (Minutes) 600W (20%) 40 125 225 1500W (50%) 12 50 99 2400W (80%) 6 30 60 3000W (100%) 4 24 47 NOTE: Backup times are estimated for typical applications. Actual performance will depend on load and battery conditions. DA - 14058 Worldwide Version 2 July 20, 2011 Page 11

Technical Specifications Unit Dimensions (HxWxD) 3.5 x 17.5 x 25 inches / 8.9 x 44.5 x 63.5 cm Shipping Dimensions Unit Weight Shipping Weight BTU Break Down Electrical Input Electrical Output Battery Communications 11.25 x 23.48 x 36.25 inches / 28.57 x 59.64 x 92.07 cm 82 lbs/37 kg 89 lbs UPS and 127 lbs ERM / 40.37 kg & 57.6 kg BTU On Line BTU On Battery Battery Type Voltage Range Frequency 540 BT/hr 1138 BTU/hr 12 V, 5 AH, sealed, maintenance-free, rechargeable, valve regulated leadacid batteries with a 3-5 year service life at 25C (77F). See Model Matrix for nominal and user selectable voltage settings 50/60 Hz Online Efficiency 95% REPO Online Regulation On battery Regulation Voltage Wave Form Connections Output Protection Type Extended Batteries Backup Time Recharge Time Serial Ports Option Slot Option Cards LED Indicators Software Environmental and Safety Operating Temperature Non-operating Temperature Operating Humidity Remote Emergency Power-Off disables AC power to load -10% to +6% of nominal voltage ±5% of nominal voltage Sine wave See Model Selection Matrix; divided into 2 Load Segments Re-settable circuit protectors Maintenance-free, sealed, valve-regulated lead acid (VRLA) Up to two ERMs supported See Backup Times Chart <3 hours to 80% usable capacity; <48 hours for complete recharge Standard DB-9 and USB ports (ships with communication cables) One Storage Humidity 5% to 95% Operating Altitude Transit Altitude Audible Noise Safety Markings Safety Certifications REPO Port HP UPS Network Module LED and switch membrane integrated into the front panel HP Power Protector software available 10 C to 40 C (50 F to 104 F); UL-tested at 25 C (77 F) -20 C to 50 C (-4 F to 122 F) 20% to 80% (non-condensing) Up to 6,562 ft (2000 m) above sea level 49,212 ft (15,000 m) above sea level <45db in normal operation. <50bd on battery operation NA/JPN: UL, cul Int'l: GS, CE, GOST UL1778, UL60950-1; CSA22.2 No.107.3-05,; EN60950-1 IEC62040-1-1 Meets NEC code 645-10 and 645-11and UL requirements DA - 14058 Worldwide Version 2 July 20, 2011 Page 12

Technical Specifications Environment-friendly Products and Approach End-of-life Management and Recycling Hewlett-Packard offers end-of-life HP product return, trade-in, and recycling programs in many geographic areas. For trade-in information, please go to: http://www.hp.com/go/green. To recycle your product, please go to: http://www.hp.com/go/green or contact your nearest HP sales office. Products returned to HP will be recycled, recovered or disposed of in a responsible manner. The EU WEEE directive (2002/95/EC) requires manufacturers to provide treatment information for each product type for use by treatment facilities. This information (product disassembly instructions) is posted on the Hewlett Packard web site at: http://www.hp.com/go/green. These instructions may be used by recyclers and other WEEE treatment facilities as well as HP OEM customers who integrate and re-sell HP equipment. Copyright 2011 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. DA - 14058 Worldwide Version 2 July 20, 2011 Page 13