Parallel SMF (PSM) in the Data Centre



Similar documents
Low Cost 100GbE Data Center Interconnect

Specifying Optical Fiber for Data Center Applications Tony Irujo Sales Engineer

How To Make A Data Center More Efficient

Data Center Optimization: Component Choice. Innovative Design. Enabling Infrastructure

The ABC of Direct Attach Cables

Data Center Design for 40/100G

Migration Strategy for 40G and 100G Ethernet over Multimode Fiber

Data Centre Link Survey

Your Network. Our Connection. 10 Gigabit Ethernet

Pluggable Optics for the Data Center

GIGABIT ETHERNET. Greg Hankins UKNOF16. v /04/22

Ethernet 301: 40/100GbE Fiber Cabling and Migration Practices

Evolution of Ethernet Speeds: What s New and What s Next

Optical Trends in the Data Center. Doug Coleman Manager, Technology & Standards Distinguished Associate Corning Cable Systems

Latest Trends in Data Center Optics

Specifying Optical Fiber for Data Center Applications Tony Irujo Sales Engineer

CISCO 10GBASE X2 MODULES

100 Gb/s Ethernet/OTN using 10X10 MSA Optical Modules

Global Networking Services

The Need for Speed Drives High-Density OM3/OM4 Optical Connectivity in the Data Center

The Ethernet Roadmap Applications, servers, optics, and switches

The Optical Fiber Ribbon Solution for the 10G to 40/100G Migration

100 GBE AND BEYOND. Greg Hankins NANOG52. Diagram courtesy of the CFP MSA. NANOG /06/14

Obsolete Fiber Technology? Not in my Data Center!

Arista 40G Cabling and Transceivers: Q&A

Fiber in the Data Center

Data Center Market Trends

MIGRATING TO A 40 GBPS DATA CENTER

ECONOMICS OF DATA CENTER OPTICS SPIE PHOTONICS WEST INVITED PAPER (9775-2) FEBRUARY 16, 2016

Migration to 40/100G in the Data Center with OM3 and OM4 Optical Connectivity

Whitepaper. 10 Things to Know Before Deploying 10 Gigabit Ethernet

Volume and Velocity are Driving Advances in Data Center Network Technology

HIGH QUALITY FOR DATA CENTRES ACCESSORIES AND INFRASTRUCTURE. PRODUCT CATALOG 12/2014 PRO-ZETA a.s.

HP Multimode OM3 LC/LC Optical Cables Overview. Models HP 50 m Multimode OM3 LC/LC Optical Cable

Upgrading Path to High Speed Fiber Optic Networks

Physical Infrastructure trends and evolving certification requirements for Datacenters Ravi Doddavaram

DATA CENTER APPLICATIONS REFERENCE GUIDE Networking & Storage

SFP Transceiver Specifications

Prisma IP 10 GbE VOD Line Card

Top of Rack: An Analysis of a Cabling Architecture in the Data Center

40 Gigabit Ethernet and 100 Gigabit Ethernet Technology Overview

The Need for Low-Loss Multifiber Connectivity

100 GIGABIT ETHERNET TECHNOLOGY OVERVIEW & OUTLOOK. Joerg Ammon <jammon@brocade.com> Netnod spring meeting 2012

Simplified 40-Gbps Cabling Deployment Solutions with Cisco Nexus 9000 Series Switches

Trends In Data Rate And Link Length In Evolving Optical Standards

40 and 100 Gigabit Ethernet Overview

Ethernet 102: The Physical Layer of Ethernet

Cisco Small Form-Factor Pluggable Modules for Gigabit Ethernet Applications

Design Guide. SYSTIMAX InstaPATCH 360 Traffic Access Point (TAP) Solution.

Cisco MFE and MGE SFP Transceivers Cisco Small Business Network Accessories

Next Generation 100G Client Optics

Uncompromising Integrity. Making 100Gb/s deployments as easy as 10Gb/s

10G and Beyond in the Data Center with OM3 Fiber

HUBER+SUHNER AG Phil Ward

10GBASE-T SFP+ Transceiver Module: Get the most out of your Cat 6a Cabling

Intel Ethernet SFP+ Optics

Trends and Standards In Cabling Systems

Network Topologies and Distances

Untangled: Improve Efficiency with Modern Cable Choices. PRESENTATION TITLE GOES HERE Dennis Martin President, Demartek

Features and Benefits

White Paper: 10GbE Fiber A Practical Understanding and Functional Approach

The migration path from 10G to 40G and beyond for InstaPATCH 360, InstaPATCH Plus and ReadyPATCH installations

MPO. Fast Fibre Solution for Data Centres

SRX Series Services Gateway Transceiver Reference

Fibre Channel Fiber-to-Fiber Media Converters

Optical Fiber. Smart cabling: constructing a cost-effective, reliable and upgradeable cable infrastructure for your enterprise network

Copper to Fiber Stand-Alone Media Converter. Quick Installation Guide

Data Center Design Considerations

Overview of Requirements and Applications for 40 Gigabit and 100 Gigabit Ethernet

Optimizing Infrastructure Support For Storage Area Networks

3Com Transceivers OVERVIEW. Standards-based flexible Ethernet connections KEY BENEFITS

High Speed Ethernet. Dr. Sanjay P. Ahuja, Ph.D. Professor School of Computing, UNF

40 Gigabit Ethernet and 100 Gigabit Ethernet Technology Overview

Data Centre Cabling. 20 August 2015 Stefan Naude RCDD The SIEMON Company

Plug & Play Gigabit Ethernet Media Conversion Module. Application Note

Optical Data Center Markets: Volume I Optical Opportunities Inside the Data Center

Fibre Channel Fiber Cabling

Unified Storage Networking

High density Fiber Optic connections in the Data Center. Phil Ward Datacenter Product Market Manager. HUBER+SUHNER AG

Displayport Extender via 2 multimode fibers LC Duplex Connector Extends Displayport Link up to 200 meters

Gigabit Ethernet Copper-to-Fiber Converters

10 Port L2 Managed Gigabit Ethernet Switch with 2 Open SFP Slots - Rack Mountable

Data Center Cabling Technology and Trends

Cisco SFP Optics for Gigabit Ethernet Applications

Cisco Catalyst 4500 Series Line Cards

Perle 10/100 Ethernet Media Converters

Issues Affecting the Design and Choice of Cabling Infrastructures within Data Centres

Resolution of comments 242 and 267 on Insertion loss measurements of installed fiber cables. Steve Swanson May 5, 2009

Cisco Catalyst 4500 Series Line Cards

Transcription:

1 Parallel SMF (PSM) in the Data Centre - End User Survey - Alan Flatman, Independent + Brad Booth, Independent

2 Contributors A big thank you to the following people who provided introductions to end users & helped with the survey methodology & questionnaire: Jonathan Jew, J&M Consultants Lisa Huff, Discerning Analytics Lone Hansen, BSRIA

3 Need to Assess Acceptance/Reluctance of PSM in the Data Centre PSM4 is 1 of 5 candidates for P802.3bm 500m SMF objective mixed messages being received on PSM a question of system cost effectiveness? will it fit with existing SMF infrastructure? does PSM offer evolutionary potential? need for an independent assessment no conclusions have been drawn by the authors - this is intentional! survey also relevant to 400G Study Group

4 Survey Approach early adopter respondents only EDCs and IDCs the main focus 2-tier and 3-tier DCs considered survey conducted for IEEE 802.3 all survey data to be anonymous respondents get copy of survey

5 Survey Questionnaire DC area including elec+mech rooms total physical servers in data centre max length of tier- 2/3 Ethernet links installed and planned optical fibre duplex & parallel MMF duplex & parallel SMF install PSM if system cost effective? Would you install parallel SMF+MPO connectors for 100G & higher speeds if the total cost of cabling + optical modules was similar to the total cost of duplex SMF + LC connectors + modules?

6 Survey Responses DC Types EDC / IDC mix approx 50:50 2/ 3-tier architecture approx 50:50

7 Survey Responses - Dimensions responses from 6 very large EDC/IDCs total DC real estate ~2.5 million sq. ft total server count exceeds 120,000 max link length reported was 1,000m 155m max link in 370,000 sq. ft EDC 250m max link in 1.4 million sq. ft IDC 15km max link for remote connections

8 Survey Responses - Cabling #DCs Installed #DCs Planned Duplex MMF Support 6 5 Parallel MMF Support 2 2 Duplex SMF Support 6 6 Parallel SMF Support 1 1

9 Survey Responses - PSM Attitudes #DCs Would deploy PSM if system cost was less than duplex SMF system May deploy PSM if system cost was less than duplex SMF system Opposed to PSM due to duplex orientation of installed SMF cabling 2 2 2

10 PSM in the Data Centre - Additional Observations Existing datacenter practices more or less dictate duplex connections. It is more than likely that parallel fibre will be charged as multiple duplex connections. Please note that these are recurring costs. Respondent #1 Fiber optic infrastructure represents a significant portion of our CapEx, so each strand counts. Parallel fiber, providing virtually no net bandwidth increment, is not feasible. Introducing MPO connectors into our standard cabling process would be problematic. Rate of failure and average time to troubleshoot and repair parallel fiber would be expected to increase. We see little value in multiplying fiber strand or wavelength count. Respondent #2 MPO leaves stranded strands in the back bone. There needs to be an effective way to harvest and use stranded strands. Respondent #3 The use of parallel fiber gives us the lowest overall interconnection cost and ensures the fiber plant can be used for multiple generations of optical interfaces. The economic benefit we receive by using parallel fiber outweighs any additional operational challenges we may face. Respondent #4

11 PSM in the Data Centre - Additional Observations Many large IDCs are using 100GBASE-SR10. They understand that it s cheaper than 100GBASE-LR4 but are not keen on ribbon cable solution due to its preferential bend (i.e. better in one direction). Lisa Huff, Discerning Analytics The majority of data centers are much smaller than this and cost is absolutely the biggest factor in their decision-making on fiber. It s why they are still mostly copper and OM3/4. And, while they may not use a lot of SMF right now, they are increasingly going to as the optical reach gets shorter at higher data-rates. To me, what you have here is great information, but a larger sample size of varying types of data centers should be taken. Lisa Huff, Discerning Analytics Most of the data centres are much smaller than those in the survey sample. The trends we have observed in most countries is a clear drive towards fibre, mostly MMF. The large data centres are typically 70-90% fibre, while many of the medium data centres are 50-60% in favour of fibre. The small data centres are dominated by copper. We see negligible deployment of SMF in mediumlarge data centres today. Lone Hansen, BSRIA