24 HOURS AND 3-MONTHS BOND STRENGTH BETWEEN DUAL-CURED RESIN CEMENTS AND SIMPLIFIED ADHESIVE SYSTEMS



Similar documents
Effect of salivary contamination at different steps of the bonding process on the microleakage around Class V restorations

CAN ULTRASOUND APPLICATION INFLUENCE THE BOND STRENGTH OF SELF-ADHESIVE RESIN CEMENTS TO DENTIN?

Adhesive Solutions. Scotchbond Universal Adhesive. SEM pictures of Scotchbond Universal Adhesive. One bottle for all cases! Total-Etch and Self-Etch

CORRELATION OF THE HYBRID LAYER THICKNESS AND RESIN TAGS LENGTH WITH THE BOND STRENGTH OF A SELF-ETCHING ADHESIVE SYSTEM

Influence of Water Storage Time on the Bond Strength of Etch-and-Rinse and Self-Etching Adhesive Systems

Bond strength evaluation of self-etch and total-etch adhesive systems on intact and ground human enamel

DENT 5351 Final Examination 2007 NAME

Interaction between total-etch and self-etch adhesives and conventional and self-adhesive resin cements

A COMPARISON OF THE FILM THICKNESS OF TWO ADHESIVE LUTING AGENTS AND THE EFFECT OF THERMOCYCLING ON THEIR μtbs TO FELDSPATHIC CERAMIC

Influence of Ormocer component on the performance of dentin adhesive systems

RSBO Revista Sul-Brasileira de Odontologia ISSN: Universidade da Região de Joinville Brasil

Clinical randomized controlled study of Class II restorations of a highly filled nanohybrid resin composite (4U)

Effect of Cement Type and Water Storage Time on the Push-Out Bond Strength of a Glass Fiber Post

Etching time evaluation on the shear bond strength of two adhesive systems in primary teeth

Press Abutment Solutions

Influence of ultrasound and diamond burs treatments on microtensile bond strength

Effect of water storage and hydrophobic

Effect of storage and disinfection methods of extracted bovine teeth on bond strength to dentin

Low shrinkage composite resins: influence on sealing ability in unfavorable C-factor cavities

Intra-radicular dentin treatments and retention of fiber posts with selfadhesive

Shear bond strength of metallic brackets bonded with a new orthodontic composite

Eliminating effect of Er, Cr: YSGG laser irradiation on the smear layer of dentin

Objective: To assess microleakage in conservative class V cavities prepared with

1- Fatigue-Resistance and Microleakage of CAD/CAM Ceramic and Composite Molar crowns

Push-out bond strength of CAD/CAM-ceramic luted to dentin with self-adhesive resin cements

In 1972, Wilson & Kent introduced

Bonding Agent Underneath Sealant: Shear Bond Strength to Oil-Contaminated Enamel

Abutment Solutions For customized implant restorations fabricated with CEREC and inlab. Digital all around.

THE EFFECT OF STORAGE SOLUTIONS ON ENAMEL OF BOVINE TEETH

Effect of waiting time for placing resin composite restorations after bleaching on enamel bond strength

FORMAÇÃO DE CÁRIE AO REDOR DE COMPÓSITOS RESTAURADORES E CIMENTO DE IONÔMERO DE VIDRO

One-hour tensile bond strength of different luting agents to a NiCr alloy

Ultimate tensile strength of tooth structures

The effect of hydroxyapatite presence on the degree of conversion and polymerization rate in a model self-etching adhesive

priti crown Your patients deserve you

Heraeus Kulzer plays an active part in IADR General Session 2015 in Boston

The effects of anti-oxidant agents as neutralizers of bleaching agents on enamel bond strength

Effect of photoactivation methods and base materials on the stress generated by the polymerization shrinkage of a resin composite

Jacket crown. Advantage : Crown and Bridge

Rebilda DC. Rebilda Post System. Rebilda

Microtensile test in dental research. Controversial aspects in statistical analysis (experimental unit and premature failures)

In vivo evaluation of different techniques for establishment of proximal contacts in posterior resin composite restorations

Luting Cement. in the Clicker Dispenser. Technical Product Profile. Ketac Cem Plus

Chemical stability of two dentin single-bottle adhesives as a function of solvent loss

Correlation between marginal accuracy and fracture resistance of indirect composite restorations varying cavity preparation design

Class I and II Indirect Tooth-Colored Restorations

Tooth preparation for indirect bonded restorations (eg,

Selected Properties of Core-Buildup Materials for Prosthetic Restorations

IPS Empress CAD for CAD/CAM technology Information for Dentists. Confidence. Reliability. Esthetics. Empress CAD. The world s leading all-ceramic

Objective: The aim of this study was to evaluate the effect of multiple layers of an

Influence of ceramic primers on microshear bond strength between resin cements and zirconia-based ceramic

Er:YAG (2940nm) laser cavity preparation and semidirect composite resin restorations. A microleakage study

Comparative radiopacity of four lowviscosity

Porcelain Veneers for Children and Teens. By Fred S. Margolis, D.D.S., F.I.C.D., F.A.C.D., F.A.D.I. Abstract

Adhesion and Microleakage of CAD/CAM Crowns Using Self-adhesive Resin Cements

Assessment of variability in experiments in the operative dentistry area applied to shear bond strength tests

20TDNH 214. Course Description:

Condition assessment and repair of antenna towers concrete foundations

Every material, every indication, every time.

Deposited on: 8 June 2009

Adper Easy Bond. Self-Etch Adhesive. Your invitation to the. heavyweight showdown. November 28 30, 2010 Booth #4407.

Testing and appraisal of Lucobit polymer effect as an additive on asphalt mixture performance

Abutment fracture in a bridge supported by natural teeth and implants

Ion Beam Sputtering: Practical Applications to Electron Microscopy

FAQs - RelyX TM Unicem 2 Automix/Clicker

Single-tooth replacement in the anterior and premolar region

THE INFLUENCE OF COMPRESSIVE CYCLIC LOADING ON THE RETENTION OF CAST CROWN COPINGS CEMENTED TO IMPLANT ABUTMENTS

STEP-BY-STEP INSTRUCTIONS ON THE PROSTHETIC PROCEDURES. Straumann Anatomic IPS e.max Abutment

the new dna of high strength glass ceramics

MICROSTRUCTURAL AND MECHANICAL CHARACTERIZATION OF GRAY CAST IRON AND AlSi ALLOY AFTER LASER BEAM HARDENING

High Performance PSA in Sheet Membrane in Water Protection

Effects of Tg and CTE on Semiconductor Encapsulants

dental fillings facts About the brochure:

TABLE OF CONTENTS CHAPTER NO. TITLE PAGE NO. ABSTRACT


DOES BONDING TO DENTIN REDUCE MICROLEAKAGE OF COMPOSITE RESTORATIONS?

Randall G. Cohen, DDS 501 Floral Vale Blvd Yardley, PA Curriculum Vitae

CHAPTER 10 RESTS AND PREPARATIONS. 4. Serve as a reference point for evaluating the fit of the framework to the teeth.

Clinical Evaluation of Fixed Partial Dentures with Cast Joined Pontics

Our Mission: Protecting partially. erupted teeth. With Fuji TriageTM from GC. One of many GC solutions for caring for youngsters.

Evaluation of Survival Time of Tooth Color Dental Materials in Primary Anterior Teeth

Fire-Damage or Freeze-Thaw of Strengthening Concrete Using Ultra High Performance Concrete

While the prosthetic rehabilitation of

Composite artistry- speedy mock up

Wax-based binder for low-pressure injection molding and the robust production of ceramic parts

Use of Standards in Papers Published in Dental Journals

EVALUATION OF THE PERFORMANCE OF THE PROTECTIVE SURFACE COATINGS FOR CONCRETE

Resin based materials in prosthetic dentistry. Mercedes Linninger DDS Department of prosthodontics

Buy 1, Get 1 FREE! (Refills: Contain 2 Syringes (2g each), 20 Dispensing Tips, Technique Guide, Direction for Use)

BIOACTIVE COATINGS ON 316L STAINLESS STEEL IMPLANTS

Location of the apical foramen and its relationship with foraminal file size

Basic Properties and Application of Auto Enamels

EFFECT OF NANO-SILICA ON CONCRETE CONTAINING METAKAOLIN

How To Test A Base Axe

Influence of heat treatment on the sorption and solubility of direct composite resins

TA3 Dosimetry and Instrumentation. Evaluation of the Field Size in Dental Diagnostic Radiology System ANDRADE PS 1, POTIENS MP 1

Enamel bonding has been widely and successfully used

Hardened Concrete. Lecture No. 14

Ivocap The successful technique

ROHACELL Triple F. Complex shaped PMI Foam Cores for highly efficient FRP Composite

Transcription:

24 HOURS AND 3-MONTHS BOND STRENGTH BETWEEN DUAL-CURED RESIN CEMENTS AND SIMPLIFIED ADHESIVE SYSTEMS Thaiane R. Aguiar 1, Andrea N. Cavalcanti 2, Céres M. Fontes 2, Giselle M. Marchi 1, Leonardo Muniz 3, Paula Mathias 2 1 Department of Restorative Dentistry, Piracicaba Dental School, Campinas State University. 2 Department of Restorative Dentistry, Federal University of Bahia. 3 Bahiana Foundation for Science Development. 171 ABSTRACT This study evaluated the bonding compatibility between dualcured resin cements and simplified adhesive systems (one-step self-etch and two-step etch & rinse), measured after 24 hours and 3 months. The occlusal dentin surfaces of 24 human third molars were exposed and flattened. Teeth were randomly assigned to 3 groups and treated with different combinations of adhesive system and resin cement [G1 - Single Bond/Rely X ARC (SB/RX); G2 - Excite DSC/Variolink II (EX/VR); G3 - Adper Prompt/Rely X ARC (AD/RX)]. Indirect composite restorations were cemented on flattened surfaces, and sectioned to obtain multiple bonded beams for the microtensile bond strength test. The beams from each tooth were tested under tension after 24 hours and 3 months (ANOVA/ Tukey s test, α=5%). Failure patterns were evaluated with scanning electron microscopy. After 24h, AD/RX presented the lowest bond strength mean values. AD/RX specimens did not withstand three months storage. SB/RX and EX/VR presented similar bond strengths in both periods tested. The association AD/RX resulted in low bond strength mean values, especially after storage. Cementing indirect restorations using one-step self-etch adhesive systems and dual-cured resin cements would be clinically unreliable. Key words: dentin bonding, resin cements, system adhesive, bond strength. AVALIAÇÃO DA RESISTÊNCIA DE UNIÃO DE CIMENTOS RESINOSOS DE DUPLA POLIMERIZAÇÃO ASSOCIADOS A SISTEMAS ADESIVOS SIMPLIFICADOS APÓS 24 HORAS E 3 MESES RESUMO Este estudo avaliou a compatibilidade de união entre cimentos resinosos de dupla polimerização e sistemas adesivos simplificados (adesivo autocondicionante - 1 passo- e adesivo total-each - 2 passos), após 24h e 3 meses. A superfície oclusal de 24 terceiros molares humanos foi exposta e planificada. Os dentes foram aleatoriamente divididos em 3 grupos usados de acordo a seguinte combinação entre sistema adesivo/cimento resinoso [G1 - Single Bond/Rely X ARC (SB/RX); G2 - Excite DSC/Variolink II (EX/VR); G3-Adper Prompt/Rely X ARC (AD/RX)]. Restaurações indiretas em resina composta foram cimentadas na superfície dentinária, e seccionados em múltiplos palitos para a realização do teste de resistência de união através do ensaio de microtração. Os palitos obtidos por dente foram submetidos ao teste após 24 horas e 3 meses (ANOVA/ Tukey test, α=5%). O padrão de fratura foi observado no microscópio eletrônico de varredura. Após 24 horas, AD/RX apresentou menor valor médio de resistência de união. Os corpos-de-prova do grupo AD/RX não resistiram ao armazenamento de 3 meses. SB/RX e EX/VR demonstraram similar resistência de união em ambos os períodos avaliados. A associação AD/RX resultou em menores valores médios de resistência de união, especialmente após o armazenamento. A cimentação de restaurações indiretas utilizando sistemas autocondicionantes (1 passo) e cimentos resinosos de dupla polimerização não foi considerada clinicamente confiável. Palavras chaves: dentina, cimentos resinosos, sistemas adesivos, resistência de união. INTRODUCTION The effectiveness of adhesive techniques has expanded the range of clinical applications 1. For example, the positive results obtained using adhesive cementation in indirect restorations have increased the frequency of metal-free restoration procedures, allowing sound dental tissue to be preserved with more conservative tooth preparations 2,3. However, the clinical success of adhesive cementation is highly dependent on the bonding properties of adhesive systems and resin cements 4. Adhesive systems can be classified according to their adhesion strategies, i.e. etch & rinse or self-etch techniques 5. The simplified etch & rinse technique involves two steps: acid conditioning followed by application of a mixture of primer and adhesive monomers 6. When bonding to dentin, the rinsing and drying steps make this technique more susceptible to Vol. 22 Nº 3 / 2009 / 171-176 ISSN 0326-4815 Acta Odontol. Latinoam. 2009

172 Thaiane R. Aguiar, et al. Table 1: Materials used in the present study, with the corresponding manufacturers, batch numbers and composition. Product (batch number) Composition* Single Bond ( 3M ESPE, 4JY) Excite (Ivoclar Vivadent, F66811) Adper Prompt (3M ESPE, L29064) Rely X ARC (3M ESPE, FL-316) Variolink II( Ivoclar Vivadent, F51866/F56391) Etchant: 35% H3PO4 Bis-GMA, HEMA, PAA, ethanol, water, initiators Etchant: 35% H3PO4 DMA, HEMA, alcohol, phosphoric acid acrylate, SiO2, initiators, stabilizers Liquid-A: Methacrylated phosphoric esters, Bis-GMA, initiators, stabilizers. Liquid-B Water, HEMA, stabilizers, polyalkenoic acid Bis-GMA, TEGDMA, Zirconia/silica filler, dimethacrylate polymer, pigments, initiators Bis-GMA, UDMA, TEGDMA, fillers, catalysts, stabilizers, pigments *Bis-GMA, bisphenol-glycidyl methacrylate; HEMA, 2-hydroxyethyl methacrylate; PAA, polyalkenoic acid copolymer; DMA, dimethacrylates; TEGDMA, triethylene glycol dimethacrylate; UDMA, urethane dimethacrylate. operator error, reducing adhesive performance 7.Onestep self-etch or all-in-one systems, as they are commonly referred to, involve only one procedure 5. These systems use acidic monomer solutions that etch, prime, and bond simultaneously 8. They eliminate critical steps, such as rinsing and drying 9 that decrease the technique s sensitivity 8. Consequently, these systems are being increasingly used 6, even for adhesive cementation in indirect restorations. Adverse interactions between simplified adhesives and chemical/dual-cured resin cements have been reported 2,6,10,11. An incompatible acid-base reaction occurs between acidic monomers present in simplified systems and the tertiary amines present in the catalyst paste of resin cements, resulting in incomplete polymerization of resin cements. The higher concentration of ionic and hydrophilic groups in adhesive systems may allow the movement of water and ions from the underlying dentin even after polymerization, compromising the hermetic sealing of the dentin interface 2. Moreover, one-step self-etch systems usually have a ph of 1.0 or lower, resulting in considerably deep demineralization effects, and thus more hydrophilic interfaces that are more prone to hydrolytic degradation 12. In vitro bond strength evaluations are usually performed 24h after specimen preparation 9,13. This period of time may not be long enough to verify the efficiency of restorative and adhesive materials, both in terms of bond stability and durability 13,14. Thus, the aim of this study was to evaluate the compatibility, after 24h and 3 months, between simplified adhesives systems (two etch & rinse systems and one one-step self-etch system) and dual-cured resin cements using a microtensile bond strength test (µtbs). Additionally, the morphological characteristics of the fractured surfaces were evaluated using scanning electron microscopy (SEM). The null hypothesis tested was that combinations of simplified adhesive systems and resin cements present similar bond strength to dentin and long-term performance. MATERIAL AND METHODS This study was approved by the Ethical Committee in Research at the Federal University of Bahia. Twenty-four non-carious human third molars were disinfected with 0.5% chloramine T solution. Their roots were mounted in self-curing acrylic resin cylinders (2.5 cm diameter). The occlusal enamel was removed using 180-grit silicon carbide paper under running water, and the smear layer was standardized with 600-grit silicon carbide papers under water cooling during 1 minute. Teeth were randomly allocated to 3 groups according to the following treatments (n=8): SB/RX (Single Bond (3M ESPE, St. Paul, MN, USA)/ Rely X ARC (3M ESPE, St. Paul, MN, USA); EX/VR (Excite DSC (Ivoclar Vivadent, Schaan, Liechtenstein)/Variolink II (Ivoclar Vivadent, Schaan, Liechtenstein); AD/RX (Adper Prompt (3M ESPE, St. Paul, MN, USA)/ RelyX ARC). The composition of the materials and manufacturers are shown in Table 1. The adhesive systems and resin cements were manipulated and applied according to manufacturers instructions. The same Acta Odontol. Latinoam. 2009 ISSN 0326-4815 Vol. 22 Nº 3 / 2009 / 171-176

Dual-cured resin cements and simplified adhesive systems... 173 manufacturer was used for all groups to avoid chemical bias. Rectangular indirect restorations (4x4x6 mm) were fabricated using composite resin (Tetric Ceram, Ivoclar Vivadent, Schaan, Liechtenstein). The composite was inserted in 2.0 mm thick increments and each increment was light-activated for 20 seconds. The light output of the light curing unit (Optilight 600, Gnatus, Ribeirão Preto, SP, Brazil) was tested (500 to 600 mw/cm 2 ) with a radiometer (Curing Radiometer, model 100, Kerr Corporation, Orange, USA). The indirect composite was bonded to dentin with adhesive systems and resin cements in accordance with the manufacturer s instructions. Visible-light activation of each surface was applied for 20 s (Optilight 600). After cementation, specimens were stored in artificial saliva at 37 C for 24h. Next, they were sectioned on the mesio-distal and bucco-lingual planes using a low-speed, watercooled diamond saw (Isomet, Buehler, Lake Bluff, IL, USA). The boundaries of the restoration were discarded, six beams were obtained per tooth and the cross-sectioned area was measured with a digital caliper (727, Starrett Ind., Itu, SP, Brazil) to the nearest 0.01 mm. Beams obtained from each tooth were divided into 2 groups: half specimens were tested after 24h; the other half specimens were stored in artificial saliva (37 C) and tested after 3 months. Throughout the storage process, the artificial saliva was changed every five days. To carry out microtensile testing, specimens were attached to the flat grips of a μtbs device with cyanoacrylate glue (Super Bonder; Henckel Loctite, Itapevi, SP, Brazil) and tested under tension in a Universal Testing Machine (EMIC DL 500, São José dos Pinhais, SC, Brazil) at a cross-head speed of 0.5 mm/min, until failure. Means and standard deviations were calculated and expressed in MPa. No bond strength value was attributed for premature debonding during specimen preparation. The μtbs data were analyzed using Repeated Measures ANOVA and Tukey s test (α=5%). Table 2: Mean values (standard deviations) of µtbs (MPa). Experimental groups Single Bond + RelyX ARC Excite + Variolink II Adper Prompt + RelyX ARC 24 hours 27.76 (5.20) Aa 22.60 (9.68) Aa 13.59 (5.58) B Storage 3 months 26.61 (5.73) 7 Aa 22.87 (8.30) Aa - Means followed by the same letters are not statistically different (ANOVA/Tukey s test, =0.05). Upper case letters compare adhesive systems within storage periods. Lower case letters compare storage periods within adhesive system. Fig. 1: Failure mode distribution according to the combination between adhesive system and resin cement. After testing, each specimen was gold-sputter coated (Balzers-SCD 050 Sputter Coater, Germany) and observed by SEM (JSM 2900, JEOL, Scanning Electron Microscopy Peabody, MA, USA) to assess the failure pattern. Failure modes were classified in three types: type 1 - failure between adhesive system and dentin, and partial cohesive failure in adhesive resin; type 2 - total cohesive failure in the adhesive resin; type 3 - cohesive failure in the cement resin. RESULTS Bond strength results are shown in Table 2. All specimens from the AD/RX group aged for 3 months debonded at the cement/dentin interface during specimen storage. Therefore, this combination could not be included in the statistical analysis. SB/RX and EX/VR presented similar bond strength in both periods and were not significantly affected by storage. The failure mode distribution is described in Fig. 1. In both periods tested, SB/RX presented mainly type 3 failures (Fig. 2: SEM photomicrograph illustrating a cohesive failure in the resin cement). The most frequent type of failure in EX/VR was type 1 after 24 hours Vol. 22 Nº 3 / 2009 / 171-176 ISSN 0326-4815 Acta Odontol. Latinoam. 2009

174 Thaiane R. Aguiar, et al. Fig. 2: SEM photomicrograph illustrating a cohesive failure in the resin cement. Fig. 3: SEM photomicrograph illustrating the dentin side of a fractured specimen presenting an adhesive failure between adhesive resin and dentin. Fig. 4: SEM photomicrograph illustrating the dentin side of a fractured specimen with a total cohesive failure in the adhesive resin. (Fig. 3: SEM photomicrograph illustrating the dentin side of a fractured specimen presenting an adhesive failure between adhesive resin and dentin); and type 2 after the 3-months period (Fig. 4: SEM photomicrograph illustrating the dentin side of a fractured specimen with a total cohesive failure in the adhesive resin). AD/RX presented mainly cohesive failures within the adhesive after 24 hours. After 3-months, both type 1 and type 3 failures were observed. DISCUSSION The present study was conducted to evaluate the μtbs of dual-cured resin cements bonded to simplified adhesive systems, after 24 hours and 3 months storage. Early bond strength measurements might provide an important reference regarding the bonding capability of adhesive materials 9. Nevertheless, it is widely accepted that long-term clinical studies provide more realistic results with respect to the efficiency of restorative materials 14, but the drawbacks of such studies are the high cost and extensive length of time 15. To overcome these limitations, in vitro methods, such as artificial aging, were developed to simulate aging conditions in an effort to provide information about bonding durability. In this study, specimens were stored in artificial saliva to simulate aging. However, other clinically-related factors, such as chewing stress, ph and temperature variations, were not simulated in this study. The storage method and the solution used are important variables in this study. Storage solutions have a significant effect on the leachability of filler particles, and artificial saliva might promote a greater degradation of resin-based materials than distilled water 16. Thus, it can better simulate the intraoral conditions. The interfacial bonding area exposed to the storage period may also play an important role in specimen degradation 14. In the present study, specimens with 1 mm 2 interfacial bonding areas were stored in artificial saliva. This method was chosen to accelerate the degradation of the interfaces between resin cements, adhesive systems and dentin. The etch & rinse systems (SB/RX and EX/VR) showed statistically similar bond strength values, irrespective of length of storage period. Therefore, the 3-months period may not be long enough to age restorative materials with improved bonding per- Acta Odontol. Latinoam. 2009 ISSN 0326-4815 Vol. 22 Nº 3 / 2009 / 171-176

Dual-cured resin cements and simplified adhesive systems... 175 formance, such as the two-step etch & rinse systems. On the other hand, the bond created using the one-step self-etch system was incapable of withstanding 3 months of storage, suggesting that this adhesive system does not present a reliable longterm capacity for cementing indirect restorations. The relatively high dentin permeability found in simplified self-etch systems results from the increased concentration of acidic monomers 6,17. The faster hydrolytic degradation of these systems in humid environments might justify the incidence of premature failures in the AD/RX group 12,18. Similar incidences of premature failure have previously been reported 1. Type 2 failure mode was frequently noted in the non-aged group AD/RX. It can be hypothesized that the higher permeability and incomplete light activation of the one-step self-etch system promoted a faster hydrolytic degradation, premature failure and, consequently, the loss of specimens. On the other hand, SB/RX groups demonstrated fewer failures involving the hybrid layer, since mainly cohesive failures in the cement resin were observed. In addition to hydrolytic degradation, the chemical incompatibility between chemical/dual-cured resin cements and simplified adhesive systems can negatively influence the adhesive cementation of indirect restorations 6,8,19. The result of this adverse reaction is the incomplete polymerization of resin-based materials 2. Since the degree of conversion of resin-based materials is directly related to their me chanical properties 11, an adequate polymerization of the resin cement is a fundamental prerequisite for restoration stability 20. Although simplified etch & rinse systems might also present a chemical incompatibility with dual cure cements, the results of this study indicate that this effect might be less pronounced than with one-step self-etch systems (AD/RX group). Within the limitations of this study, it could be concluded that there is no satisfactory evidence to justify the use of simplified self-etch systems and dual-cured composites for cementing indirect restorations. Findings showed that this association resulted in low bond strength mean values, especially after storage. However, bonding of indirect composite using two-step etch & rinse adhesive systems and chemical/dual-cured resin cement was not significantly affected by storage. ACKNOWLEDGMENTS This study was supported by Federal University of Bahia (PIBIC/CNPq grant # 117951/2004-8). CORRESPONDENCE Dra. Paula Mathias. Faculdade de Odontologia da Universidade Federal da Bahia. Av. Araújo Pinho, # 62, Canela, Salvador, BA, 40110-150. Brazil. Tel (+5571) 33365776 / Fax (+5571)33550081. e-mail: pmathias@yahoo.com REFERENCES 1. Carracho HG, Soares CG, Heredia AR, Burnett Junior LH, Spohr AM. Compatibility between self-cured resin cement and simplified photo-cured adhesives associated to a universal catalyst. Braz Dent Scienc 2005;8:45-53. 2. Pegoraro TA, Silva NRFA, Carvalho RM. Cements for Use in Esthetic Dentistry. Dent Clin North Am 2007;51:453-471. 3. De Munck J, Vargas M, Van Landuyt K, Hikita K, Lambrechts P, Van Meerbeek B. Bonding of an auto-adhesive luting material to enamel and dentin. Dent Mater 2004;20: 963-971. 4. Arrais CA, Giannini M, Rueggeberg FA, Pashley DH. Microtensile bond strength of dual-polymerizing cementing systems to dentin using different polymerizing modes. J Prosthet Dent 2007;97:99-106. 5. Van Meerbeek B, Vargas M, Inoue S, Yoshida Y, Peumans M, Lambrechts P, et al. Adhesives and cements to promote preservation dentistry. Oper Dent 2001;26 (Suppl 6):119-144. 6. Tay FR, Frankenberger R, Krejci I, Bouillaguet S, Pashley DH, Carvalho RM, et al. Single bottle adhesives behave as permeable membranes after polymerization. I. In vivo evidence. J Dent 2004;32:611-621. 7. Finger WJ, Balkenhol M. Rewetting strategies for bonding to dry dentin with an acetone-based adhesive. J Adhes Dent 2000;2:51-56. 8. Tay FR, Pashley DH. Aggressiveness of contemporary selfetching systems. I: Depth of penetration beyond dentin smear layers. Dent Mater 2001;17:296-308. 9. Duarte RM, de Goes MF, Montes MA. Effect of time on tensile bond strength of resin cement bonded to dentine and low-viscosity composite. J Dent 2006;34:52-61. 10. Cheong C, King NM, Pashley DH, Ferrari M, Toledano M, Tay FR. Incompatibility of self-etch adhesives with chemical/dual-cured composites: two-step vs one-step systems. Oper Dent 2003;28:747-755. 11. Latta MA, Kelsev WP 3rd, Kelsev WP 5th. Effect of polymerization mode of adhesive and cement on shear bond strength to dentin. Am J Dent 2006;19:96-100. 12. Dong CC, McComb D, Anderson JD, Tam LE. Effect of mode of polymerization of bonding agent on shear bond Vol. 22 Nº 3 / 2009 / 171-176 ISSN 0326-4815 Acta Odontol. Latinoam. 2009

176 Thaiane R. Aguiar, et al. strength of autocured resin composite luting cements. J Can Dent Assoc 2003;69:229-234. 13. Burrow MF, Satoh M, Tagami J. Dentin bond durability after three years using a dentin bonding agent with and without priming. Dent Mater 1996;12:302-307. 14. Loguercio AD, Uceda-Gomez N, Carrilho MR, Reis A. Influence of specimen size and regional variation on long-term resin-dentin bond strength. Dent Mater 2005;21:224-231. 15. Nikaido T, Kunzelmann KH, Chen H, Ogata M, Harada N, Yamaguchi S, et al. Evaluation of thermal cycling and mechanical loading on bond strength of a self-etching primer system to dentin. Dent Mater 2002;18:269-275. 16. Söderholm KJ, Mukherjee R, Longmate J. Filler leachability of composites stored in distilled water or artificial saliva. J Dent Res 1996;75:1692-1699. 17. Salz U, Mücke A, Zimmermann J, Tay FR, Pashley DH. pka value and buffering capacity of acidic monomers commonly used in self-etching primers. J Adhes Dent 2006;8:143-150. 18. Güler AU, Yilmaz F, Yenisey M, Güler E, Ural Ç. Effect of acid etching time and a self-etching adhesive on the shear bond strength of composite resin to porcelain. J Adhes Dent 2006;8:21-25. 19. Finger WJ, Osada T, Tani C, Endo T. Compatibility between self-etching adhesive and self-curing resin by addition of anion exchange resin. Dent Mater 2005;21:1044-1050. 20. Hofmann N, Papsthart G, Hugo B, Klaiber B. Comparison of photo-activation versus chemical or dual-curing of resinbased luting cements regarding flexural strength, modulus and surface hardness. J Oral Rehabil 2001;28:1022-1028. Acta Odontol. Latinoam. 2009 ISSN 0326-4815 Vol. 22 Nº 3 / 2009 / 171-176