Data Center. Pre-terminated. Patch Panel System. Cabling Systems Simplified. Patch Panels. 10G + Gigabit. Patch Cords. Plug & Play Installation



Similar documents
Presenters Brett Weiss, Gabe Martinez, Brian Kroeger.

Data Centre & Enterprise Solutions. RapidNet

IT Cabling Solutions

Specifying an IT Cabling System

InstaPATCH ZERO Solution Guide

MPO. Fast Fibre Solution for Data Centres

Structured and Point to Point Network Cabling for Industrial Automation

Data Center Cabling Design Trends

Security & Surveillance Cabling Systems

AMP NETCONNECT CABLING SYSTEMS FOR DATA CENTERS & STORAGE AREA NETWORKS (SANS) High-density, High Speed Optical Fiber and Copper Solutions

Performance Verification of GigaSPEED X10D Installations with Fluke Networks DTX 1800 CableAnalyzer

Accelerating Light. Copper Cabling Solutions. Category 6A

Overcoming OM3 Performance Challenges

DATA CENTER NETWORK INFRASTRUCTURE. Cable and Connectivity for the Most Demanding Networks. BerkTekLevitonTechnologies.com

How to Choose the Right Cable Category

HIGHSPEED ETHERNET THE NEED FOR SPEED. Jim Duran, Product Manager - Americas WHITE PAPER. Molex Premise Networks

Network Design. Yiannos Mylonas

AMPTRAC TM CONNECTIVITY MANAGEMENT SYSTEM

InstaPATCH Cu Cabling Solutions for Data Centers

ADC s Data Center Optical Distribution Frame: The Data Center s Main Cross-Connect WHITE PAPER

ADC-APC Integrated Cisco Data Center Solutions

The High Cost of a Low-Cost Cable Certification Tester

ANSI/TIA/EIA A, Commercial Building Telecommunications Cabling Standard.

Table of Contents. Fiber Trunking 2. Copper Trunking 5. H-Series Enclosures 6. H-Series Mods/Adapter Panels 7. RSD Enclosures 8

Managing High-Density Fiber in the Data Center: Three Real-World Case Studies

Copper Pre-terminated Assemblies

Copper Cabling Infrastructure Offering

Pretium EDGE HD Solutions

Implementing Fast Ethernet

Migration Strategy for 40G and 100G Ethernet over Multimode Fiber

AMP NETCONNECT Data Center Cabling Solutions

The Evolution of Copper Cabling Systems from Cat5 to Cat5e to Cat6 Copper Cabling Standards and Technical Aspects

ATTACHMENT F 050R CABLE AND WIRING SERVICES FUNCTIONAL AREA I PRICE PROPOSAL FORM Amendment 6

Excel Pre-terminated Copper and Fibre Optic Systems

Reliable, Consistent, Quality

Maintaining Proper Polarity for Modular Pre-terminated Fiber Systems. Rudolph A. Montgelas Fiber Optic Senior Product Manager Ortronics/Legrand

Patch Cords for Data Center Applications

The Optical Fiber Ribbon Solution for the 10G to 40/100G Migration

Session 2; Cabling Technology in the Data Centre Media Choices; Copper Twisted Pair

How To Plan A Data Center Network

SYSTIMAX Solutions. GigaSPEED X10D Shielded (F/UTP, S/FTP) Solution Guide Europe, Middle East and Africa Regions.

ANSI/TIA-942 Telecommunications Infrastructure Standard for Data Centers

Data Center Standards Making Progress on Many Fronts. Jonathan Jew J&M Consultants, Inc

Cable Assembly Solutions at the Speed of Light

PANDUIT is a Technology Developer Partner for Storage Networking Hardware. FIBER OPTIC CABLING SYSTEM SOLUTIONS B EYOND T HE G LASS

Upgrading Path to High Speed Fiber Optic Networks

Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)

THE IMPACT OF CURRENT TRENDS ON THE DATA CENTER COMMUNICATIONS CABLING INFRASTRUCTURE

ECONOMICS OF DATA CENTER OPTICS SPIE PHOTONICS WEST INVITED PAPER (9775-2) FEBRUARY 16, 2016

SECTION COMMUNICATIONS OPTICAL FIBER OSP CABLING

Gigabit Switching Ethernet Media Converters - Product User Guide

ADC Structured Cabling Solutions

Zone Distribution in the Data Center

Obsolete Fiber Technology? Not in my Data Center!

Data Center Infrastructure Development

Chapter 4 Connecting to the Internet through an ISP

Patch Cords / Cable / Cable Assemblies. Patch. Cords/Cable/ Premise Connectivity Systems. Cable Assemblies

How To Make A Data Center More Efficient

Faster Method for Connecting Customers in the Colocation Data Center

CATEGORY 8: UNDERSTANDING THE NEW CATEGORY OF PERFORMANCE FOR BALANCED TWISTED PAIR CABLE

Innovative Connectivity Solution for Maximum Performance and Security

Corning Cable Systems Optical Cabling Solutions for Brocade

Data Center Architecture with Panduit, Intel, and Cisco

Innovation. Volition Network Solutions. Leading the way in Network Migration through Innovative Connectivity Solutions. 3M Telecommunications

Optimizing Infrastructure Support For Storage Area Networks

What are the requirements for a Home Network?

Migration to 40/100G in the Data Center with OM3 and OM4 Optical Connectivity

Specification SFTP CAT6 Network Cable 23AWG CU

Total Solutions Verification

What is a Datacenter?

Data Center Topology Guide

How To Make A Fibre Cable For A Data Centre

Category 6 UTP - Cabling System

EAGLE Power over Ethernet Products for IP Powering Applications. Flexibility, Simplicity and Value LAN POWER SYSTEMS. Trend Datacom USA, Inc.

Data Center Infrastructure Solution

DEPARTMENTAL REGULATION

Corning Cable Systems Optical Cabling Solutions for Brocade

SHEET 1 COMMUNICATION NETWORKS COMPUTER AND TELEPHONE SYSTEMS

Top of Rack: An Analysis of a Cabling Architecture in the Data Center

NUIG Campus Network - Structured Cabling System Standards Information s Solutions & Services (ISS)

Technology Solution Guide. Deploying Omnitron PoE Media Converters with Aruba Access Points and AirMesh Routers

Cascade Profiler Fibre Channel SAN Attached Storage Installation Guide. Version 8.2 March 2009

Plug & Play Gigabit Ethernet Media Conversion Module. Application Note

16-Port and 24-Port 10/100 Switches

AWG: Cat5e: Cat6: Cat6A:

Arista and Leviton Technology in the Data Center

ADC KRONE s Data Centre Optical Distribution Frame: The Data Centre s Main Cross-Connect WHITE PAPER

Mixed High-Speed Ethernet Operations over Different Categories of Bundled UTP Cable

Data Center Optimization: Component Choice. Innovative Design. Enabling Infrastructure

1080P. Extender for HDMI over one CAT5. GTV-HDBT-CAT5 User Manual. gefentv.com

Cabinets 101: Configuring A Network Or Server Cabinet

1. Furnish and install faceplate and modular jacks at each single gang outlet as described below:

Data Centre Design ready for your future

BICSInews. plus. Show Issue. september/october 2012 volume 33, number 5. + Migration to High-Speed Ethernet

Design Guide. Universal Connectivity Grid. SYSTIMAX Solutions from CommScope

Uniprise Solutions. Information Security Network Solutions

GEU Port Gigabit Switch

TCTC Cabling Specifications

Category 6 Solutions. 4. Category 6 Solutions. 09/ IN TrueNet Structured Cabling. Introduction Cable Patch Panels... 4.

Panduit 28 AWG Patch Cords Installation Guideline

Transcription:

Data Center Pre-terminated Patch Panel System Patch Panels Plug & Play Installation 10G + Gigabit Patch Cords Bundled + Labeled Cabling Systems Simplified

Our Mission At Cablesys, our mission is to simplify cabling systems for your data center projects. We take complex copper and fiber systems and make them EASY to order and EASY to install. Our systems are assembled in California according to your specification, come with a 15 year end-to-end performance warranty, and are ready to go right out of the box. Traditional Cabling System vs. Pre-terminated Cabling System Traditional Cost 50% Less labor and material cost Traditional Time 90% Less installation time Factory Tested no need to buy test equipment Single Vendor no waiting for materials from multiple vendors Pre-terminated No Training or certifying staff Modular Design for flexible upgrades Pre-terminated 15 Year Warranty right out of the box 2 Cablesys

Copper Performance Fiber page4 page12 db 120 100 80 60 40 Tested up to 5.7dB Headroom NEXT @ Remote 12-36 12-45 12-78 36-45 36-78 45-78 Limit 20 0 50 100 150 200 250 CAT 6 UTP tested per TIA Permanent Link specification Complies with ANSI/TIA-942-A-1 standard for data centers Exceeds ANSI/TIA 568-C.2 industry standard UL listed and ETL verified Frequency Tested up to <= 0.1 db Insertion Loss 45 40 35 30 25 20 15 10 5 0 99% 100% 100% 100% 100% 100% 100% 100% Bin Rangrequencmulative % 95% 97% 0.02 35 40 18% 0.04 36 36% 0.0636 35 40 56% 83% Fiber count 0.08 30 71% 0.1 25 83% 0.12 24 95% 30 71% 0.14 3 97% 0.16 4 99% 0.18 2 100% 56% 25 24 0.2 1 100% 0.22 0 100% 0.24 0 100% 0.26 0 100% 0.28 36% 0 100% 0.3 0 100% 18% IL Histogram 3 4 2 1 0 0 0 0 0 0.02 0.04 0.06 0.08 0.1 0.12 0.14 0.16 0.18 0.2 0.22 0.24 0.26 0.28 0.3 IL Bin Range OM3 multimode fiber tested per TIA specification 83% tested <=0.1 db, 99% tested <=0.16 db Exceeds ANSI/TIA 568-C.3 industry standard Beats the industry average of 0.75 db Complies with IEEE 802.3 and IEC-60793-2-10 standards 100% 90% 80% 70% 60% 50% 40% 30% 20% 10% 0% cablesys.com/pnp 800.555.7176 cs@cablesys.com 3

Copper Pre-terminated Plug & Play Patch Panel Cabling System Features Pre-terminated CAT 6A, CAT 6, and CAT 5e To T-568-A or T-568-B wiring Bundled With durable PEP retardant yarn Six (6) cables per bundle Labeled On cables and bundles To your specification Tested To ANSI/TIA 568-C.2 industry standard 15 year end-to-end performance warranty Kitted Pre-sort products into kits so they are easy to allocate To your specification 4 Cablesys

Ideal locations: Enterprise data centers Colocation facilities Server farms Cloud storage networks Telecommunication rooms Traditional Cabling System Pre-terminated Cabling System cablesys.com/pnp 800.555.7176 cs@cablesys.com 5

Bezel to Modular Plugs For connectivity between patch panel and a network switch. Model # PCB Bezel to Bezel For connectivity between patch panels. Model # PCA 1. Choose Connectivity Model # Bezel to Bezel PCA Bezel to Modular Plugs PCB Bezel to Mobile Box PCC Bezel to Outlet Box PCC 2. Choose Cable Rating Riser-rated CMR Plenum-rated CMP Consider fire rating of material and airflow. Most data center environments can use riser-rated cable (CMR). Use CMR in vertical settings, such as cable running between floors through cable risers. Use plenum-rated cable (CMP) in raised flooring systems, drop ceilings, and air handling ducts. Always consult with city or building authorities for the latest code before deciding the type of cable. 6 Cablesys

Bezel to Outlet Box For connectivity between a patch panel and mobile box outlets. Model # PCC Bezel to Mobile Box For connectivity between a patch panel and mobile box outlets. Model # PCC 3. Choose Bandwidth 10G CAT 6A Shielded (FTP) 10G CAT 6A Unshielded (UTP) 1G CAT 6e Unshielded (UTP) VoIP CAT 5e Unshielded (UTP) Consider what active equipment or devices will be supported throughout the entire network. Use Foiled Twisted Pair (FTP) in environments with high Electromagnetic Interference (EMI) or Radio Frequency Interference (RFI). Use Unshielded Twisted Pair (UTP) in environments with low interference. 4. Choose Length Standard (25, 50, 75 and 100 feet) Custom (10 to 295 feet) Consider accessibility to active equipment and the layout of the room when measuring, then round up to the nearest foot. We pre-build and stock cable assemblies in standard lengths to help reduce our lead time and ship orders faster. We also custom build up to 295 feet per TIA standard. cablesys.com/pnp 800.555.7176 cs@cablesys.com 7

Installation Step 1. Install bracket panel. The panel fits 19 inch rack mount widths. Step 2. Open package. Step 3. Snap in bezels. Done! 8 Cablesys

Cable Management Brackets Three (3) and five (5) inch depths Supports front and rear cables Fits 19 inch rack mount widths Support Rear Cable Use a five (5) inch bracket to support cable on the rear of the patch panel. cablesys.com/pnp 800.555.7176 cs@cablesys.com 9

TM Bundle6 Patch Cords Model # BC6 We bundled and labeled six copper patch cords to save you time and make patching easier. 1. Choose Bandwidth 10G CAT 6A Shielded (FTP) 1G CAT 6e Unshielded (UTP) VoIP CAT 5e Unshielded (UTP) * 2. Choose Length Standard (7, 10, and 15 feet) Custom (5 to 295 feet) *Available in custom length only Bundled To route cables faster. Wrap is removable. 10 Cablesys

Labeled To easily identify cables. All-in-One Package To save time from opening multiple packages. cablesys.com/pnp 800.555.7176 cs@cablesys.com 11

Fiber Pre-terminated Plug & Play Patch Panel Cabling System Features Pre-terminated LC fiber connectors 15 year end-to-end performance warranty Bundled With durable PEP retardant yarn Six (6) cables per bundle Labeled On cables and bundles To your specification Tested To ANSI/TIA 568-C.3 industry standard 0.2 db or less Insertion Loss Kitted Pre-sort products into kits so they are easy to allocate To your specification 12 Cablesys

Ideal locations: Enterprise data centers Colocation facilities Server farms Cloud storage networks Telecommunication rooms Traditional Cabling System Pre-terminated Cabling System cablesys.com/pnp 800.555.7176 cs@cablesys.com 13

Bezel to Patch Cords For connectivity between patch panel and a network switch. Model # PFB Bezel to Bezel For high density connectivity between patch panels. Model # PFA 1. Choose Connectivity Model # Bezel to Bezel PFA Bezel to Patch Cords PFB Bezel to Outlet Box PFC MPO Cassette to Cassette PFD 2. Choose Cable Rating Riser-rated OFNR Plenum-rated OFNP Consider fire rating of material and airflow. Most data center environments can use riser-rated cable (OFNR). Use OFNR in vertical settings, such as cable running between floors through cable risers. Use plenum-rated cable (OFNP) in raised flooring systems, drop ceilings, and air handling ducts. Always consult with city or building authorities for the latest code before deciding the type of cable to use. 14 Cablesys

Bezel to Outlet Box For connectivity between a patch panel and mobile box outlets. Model # PFC Cassette to Cassette For high density connectivity between patch panels. Model # PFD 3. Choose Bandwidth 10G OM4 (for up to 550 meters) 10G OM3 (for up to 300 meters) 1G 50/125 µm (for up to 550 meters) 1G 62.5/125 µm (for up to 275 meters) Singlemode 4. Choose Fibers + Length Fiber (12 or 24 LC fibers) Length (3 meters or more) Consider accessibility to active equipment and the layout of the room when measuring, then round up to the nearest meter. We can custom build OM4 up to 550 meters and OM3 up to 300 meters. Consider the maximum operating distance to support active equipment or devices throughout the entire network. cablesys.com/pnp 800.555.7176 cs@cablesys.com 15

Installation Step 1. Install bracket panel. The panel fits 19 inch rack mount widths. Step 2. Open package. Step 3. Snap in bezels, bezels. DONE! Done! 16 Cablesys

Cable Management Brackets Three (3) and five (5) inch depths Supports front and rear cables Fits 19 inch rack mount widths Support Rear Cable Use a five (5) inch bracket to support cable on the rear of the patch panel. cablesys.com/pnp 800.555.7176 cs@cablesys.com 17

TM Bundle6 Fiber Patch Cords Model # BF6 We bundled and labeled six fiber patch cords to save you time and make patching easier. 1. Choose Bandwidth 10G OM4 OFNP * 10G OM3 OFNR 1G 50/125 µm OFNP * 1G 62.5/125 µm OFNP * Singlemode OFNP * 2. Choose Length Standard (1 to 15 meters) Custom (1 meter or more) *Available in custom length only Bundled To route cables faster. Wrap is removable. 18 Cablesys

Labeled To easily identify cables. All-in-One Package To save time from opening multiple packages. cablesys.com/pnp 800.555.7176 cs@cablesys.com 19

Data Center Pre-terminated Patch Panel System cablesys.com/pnp 10G + Gigabit Patch Panels Plug & Play Installation Patch Cords Bundled + Labeled Connect with us on cablesys.com/linkedin 800.555.7176 cablesys.com cs@cablesys.com 2100 East Valencia Drive, Suite D, Fullerton, CA 92831 USA Copyright 2015, Cablesys. Cablesys and the Cablesys logo are a registered trade name and trademark. All rights reserved. All other trade names and trademarks are the property of their respective owners. GCP&P0015