Installation Guide for. 10/100BaseT Port Aggregator Tap with Active Response. Models PA-CU-AR, PAD-CU-AR. Doc. PUBPACUARU Rev.



Similar documents
Installation Guide for. 10/100 to Triple-speed Port Aggregator. Model TPA-CU Doc. PUBTPACUU Rev. 1, 12/08. In-Line

Installation Guide for GigaBit Fiber Port Aggregator Tap with SFP Monitor Ports

Installation Guide for Gig Zero Delay Tap and 10/100/1000BaseT Tap

Installation Guide for GigaBit Fiber Port Aggregator Tap with SFP Monitor Ports

Installation Guide for GigaBit Fiber Media Converter

GEU Port Gigabit Switch

ALL8808POE. 8 Port Gigabit PoE+ Switch. Manual

Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)

FriendlyNet Hub 5-Port or 8-Port Ethernet Hub User s Manual

8-Port PoE Network Switch

USER S MANUAL. Ethernet 10/100 Transceiver Series DL221/DL221A

Ixia Net Optics 10G Regen Tap

16-Port and 24-Port 10/100 Switches

PT100 Portable TAP. User Guide. Revision 1.0

FSW-0505TX/0805TX 5/8 Port SOHO 10/100Mbps NWay Switch FSW-0505TX FSW-0805TX. 5/8 Port SOHO 10/100Mbps NWay Switch. User s Manual. (Revision 1.

D-Link DES-1024D 24-Port 10/100Mbps Ethernet Switch. Manual

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

User Manual PT-E-HIP

DES-1005P 5-Port 10/100Mbps with 1-Port PoE Unmanaged Switch

Gigabit Switching Ethernet Media Converters - Product User Guide

USER MANUAL MODEL 2300M SERIES. OpticLink Ethernet Media Converters (2300M, 2310M, 2311M, & 2312M)

M7250P. PoE Powered. Gigabit Ethernet Media Converter 1000BASE-TX TO 1000BASE-SX/LX. Installation Guide

MDI/MDIX) FEP-32008T-3

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

User's Manual. 8-Port 10/100Mbps with 4-Port PoE Fast Ethernet Switch FSD-804P - 1 -

Gigabit Desktop. manual Models & Model shown: INT / UM

Net Optics Learning Center Presents The Fundamentals of Passive Monitoring Access

5-port 10/100Base-TX Industrial Switch (314500) User s Guide

User Guide. MC100CM MC110CS Fast Ethernet Media Converter. MC111CS MC112CS WDM Fast Ethernet Media Converter

Ixia Director TM. Powerful, All-in-One Smart Filtering with Ultra-High Port Density. Efficient Monitoring Access DATA SHEET

8 Port Gigabit 10M/100M/1000M Fast Ethernet Switch. User Manual

M3 ORANGE single-slot Cradle. User Guide. Product Number: A-1CR-US0D-030-R00, A-1CR-U0ED-030-R00. Compatible Device(s): M3 ORANGE

10 Port L2 Managed Gigabit Ethernet Switch with 2 Open SFP Slots - Rack Mountable

Quick Installation Guide. EtherFast 10/100M Switch. Model No.: SP624R.

Quick Installation Guide 8-Port 10/100/1000Mbps Green Switch

HP 1405 Small Office Switch Series

NS-205-IP67 5-Port Industrial 10/100 Mbps Ethernet Switch with IP67 Casing

PoE+ Extender Switch User's Manual. Rev W

User Guide TL-SG1016/ TL-SG /24-port Gigabit Ethernet Switch

MICROSENS Media Converter 10/100/1000T to Gigabit Fiber

8-port 10/100Base-TX +2-port 100Base-FX Switch. User s Guide

HP V1405 Switch Series. Product overview. Key features. Data sheet

FCC Certifications. CE Mark Warning

ENET-710. ENET Ethernet Module ENET-710 JAN / 06 FOUNDATION

Single Port T1/E1 Tap

Networking and High Availability

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

Moxa EtherDevice Switch

Turning Copper into Gold

Perle 10/100 Ethernet Media Converters

M3 Single-Slot Cradle. User Guide. Cradle Model: A-1CR-U R00, A-1CR-U00D-040-R00, A-1CR-US R00, A-1CR-U0ED-110-R00

User Guide TL-SG1016D 16-Port Gigabit Switch TL-SG1024D 24-Port Gigabit Switch

1080P. Extender for HDMI over one CAT5. GTV-HDBT-CAT5 User Manual. gefentv.com

SPEED-DSL 2.3 Ethernet connection over 2-wires up to 2.3 Mbit/s. Manual

16-Port Gigabit Green Switch (TEG-S16Dg) 24-Port Gigabit Green Switch (TEG-S24Dg)

Network Design. Yiannos Mylonas

FriendlyNET FX Slot Modular Switch. User s Manual

8-Port PoE Network Switch

CriticalConneX. 10/100 CriticalTAP User Guide

YM.SW.105.UM.EN.D00REV FH11 Fri Jul 25 16:00: Page 1

CriticalConneX. 100/1000 CriticalTAP User Guide

Provides one channel for Ethernet over existing

palm Switch Port 10/100 Base-TX Switch with Auto MDI/MDI-X User Guide

How To Use A Network Instrument Ntap

USER MANUAL. Model U ForeFront Alarm Card SALES OFFICE (301) TECHNICAL SUPPORT (301) An ISO-9001 Certified Company

Terayon DOCSIS Modem Installation. Guide

Networking and High Availability

16-Port Gigabit Green Switch (TEG-S16Dg) 24-Port Gigabit Green Switch (TEG-S24Dg)

Speed-DSL 9.2 Ethernet connection over 8-wires up to 9.2 Mbit/s. Manual * * * *

Troubleshooting and Auto-Negotiation Features for IMC Networks Media Conversion Products

Gigabit eco-friendly Ethernet Switch AT-GS900/8. Installation Guide Rev. A

domain is known as the high side, and the less secure domain is the low side. Depending on the application, the

CriticalConneX. 100/1000 CriticalTAP User Guide. CC1220-V: CriticalConneX TAP Module CC1220-VP: CriticalConneX Portable TAP

4-Port 10/100Base-TX with PoE + 1-Port BNC / RJ-11 Industrial Ethernet Extender

8-Port 10/100Mbps 802.3at PoE + 1-Port 10/100/1000Mbps Desktop Switch

G-TAP A Series // Data Sheet

Cisco 90 Series Unmanaged Switches Cisco Small Business

KVM - DVI, USB 2.0, Cat 5 Extender

USB/VGA Cat 5 UTP Console Extender

VM-4 USB Desktop Audio Device Installation Guide

Cisco 100 Series Unmanaged Switches Cisco Small Business

HP 1405 Small Office Switch Series

VM-8 USB Desktop Audio Device Installation Guide

Network Monitoring White Paper

Megapixall Security Tools & Accessories

TP-LINK TECHNOLOGIES CO.,LTD. Website ADD FI.3,Bldg.R1-B.High-Tech Industrial Park,Shenzhen

Fail-Safe IPS Integration with Bypass Technology

Advanced features on Ethernet networks. Fulvio Risso Politecnico di Torino

Scalable. Reliable. Flexible. High Performance Architecture. Fault Tolerant System Design. Expansion Options for Unique Business Needs

IFS SP-PoE Splitter User Manual

Ethernet 5-Port Workgroup Hub

Provides one channel for Ethernet over existing

4-Port 10/100Mbps with PoE + 1-Port 100FX Industrial Ethernet Switch Wide Temperature

8-Port 10/100M N-Way Mini Switch

Cisco 110 Series Unmanaged Switches

USER MANUAL. MODEL 460 Series G.703 Coax to Twisted Pair Adapter (Balun)

Product Specifications

User Manual. Humidity-Temperature Chart Recorder. Model RH520

OPTICAL HEADEND PLATFORM OTOHP-NMS NETWORK MONITORING MODULE INSTRUCTION MANUAL

F2400 FOM II Series Fiber Optic Modem Technical Manual

Transcription:

Installation Guide for /0BaseT Port Aggregator Tap with Active Response Models PA-CU-AR, PAD-CU-AR Doc. PUBPACUARU Rev. 1, 06/06

/0 Port Aggregator Tap Contents Introduction..................................................... 1 Key Features..................................................... 3 Unpacking and Inspection.......................................... 4 Product Diagrams................................................. 4 LED Indicators................................................... 5 Application Diagrams: Memory Operation............................. 6 Cabling Guidelines................................................ 8 Connecting to the Network.......................................... 8 Connecting to the Monitoring Device(s)............................... 9 DIP Switch Settings.............................................. Active Response Tap FAQs........................................ 11 Specifications................................................... 13 Limitations on Warranty and Liability................................ 14

/0 Port Aggregator Tap PLEASE READ THESE LEGAL NOTICES CAREFULLY. By using a Net Optics Tap you agree to the terms and conditions of usage set forth by Net Optics, Inc. No licenses, express or implied, are granted with respect to any of the technology described in this manual. Net Optics retains all intellectual property rights associated with the technology described in this manual. This manual is intended to assist with installing Net Optics products into your network. Trademarks and Copyrights 2007 by Net Optics, Inc. Zero Delay TM Net Optics is a registered trademark of Net Optics, Inc. Additional company and product names may be trademarks or registered trademarks of the individual companies and are respectfully acknowledged. Additional Information Net Optics, Inc. reserves the right to make changes in specifications and other information contained in this document without prior notice. Every effort has been made to ensure that the information in this document is accurate.

/0 Port Aggregator Tap Introduction Net Optics /0 Dual Port Aggregator Taps with Active Response provide ultra-efficient access to critical links with the option to inject an active response into the network. This pioneering technology enables any two devices to simultaneously monitor a full-duplex link - using only one NIC per device. Typically, full-duplex monitoring with a network tap requires two NICs (or a dual channel NIC) one interface for each side of the tapped full-duplex connection. The Dual Port Aggregator Tap combines and regenerates these streams, sending all aggregated data out two separate passive monitoring ports. The best part of this innovation is the onboard memory to make sure traffic isn t dropped during bursts. Response Ready When active responses to network events are required, the first monitoring port can be changed to an Active Response Port using a hardware switch. The Active Response Port buffers and transmits into the network link any type of Ethernet packet, from a simple TCP reset to ICMP messages. The Active Response Port can be easily switched back to passive monitoring via the hardware switch. The combination of active response capability and passive monitoring in the Tap reduces the number of devices and network ports required for active response functionality. Buffering Prevents Lost Data The Dual Port Aggregator Tap with Active Response is designed to handle the combined traffic of a single full-duplex link. Normally, the traffic should be below the receiving capacity of the NIC, that is, less than or 0 Mbps. When the traffic queue exceeds the capacity of the NIC, the Tap buffers the overflow of up to one megabyte per side of the full-duplex connection. For your convenience, the buffers clear automatically when the traffic volume falls below the receiving capacity of the NIC. For example, if there is a traffic burst and a tap connected to a 0 Mbps network port on a monitoring device is now receiving 140 Mbps of traffic, the Tap buffers data until the burst is over. The Tap then sends the buffered data to the monitoring device until the buffer is cleared. 1

/0 Port Aggregator Tap Simple to Deploy Net Optics Dual Port Aggregator Tap with Active Response is a simple plugand-play solution addressing the fact that many monitoring systems, including most software based solutions, only offer a single channel NIC, limiting fullduplex visibility. While adding a second NIC can help maintain data integrity and visibility, there is a tradeoff in flexibility and ease-of-use. An operating system and NICs that enable binding are often required to achieve the same functionality as the Dual Port Aggregator Tap. In contrast, the Dual Port Aggregator Tap requires no additional components or configuration on the monitoring devices. All network and monitoring cables required for plug-and-play deployment are included with the /0BaseT Dual Port Aggregator Tap w/active Response. Better than Span Ports In the past, span ports were occasionally used to aggregate tapped traffic. However, in addition to other shortcomings of span port monitoring, span ports support very limited buffering and can simply drop data during bursts. The generous buffers of the Dual Port Aggregator Tap prevent data loss in these conditions. Security and Visibility Without an IP address, monitoring devices are isolated from the network, dramatically reducing their exposure to attacks. However, the monitoring device connected to the Tap still sees all full-duplex traffic as if it were in-line, including Layer 1 and Layer 2 errors. Reliability For extra uptime protection, Net Optics Taps offer redundant power connections. Should the primary power source fail, the Tap automatically switches to the backup power source. Power LEDs on the front of the Tap indicate the current power source.

/0 Port Aggregator Tap Key Features Passive, Secure Technology Supports full-duplex monitoring with a single NIC, increasing monitoring efficiency Regeneration Tap technology enables two devices to simultaneously monitor all aggregated traffic using only one NIC per device One megabyte of memory for each side of the full-duplex link (two megabytes memory, total) prevents data loss during excessive traffic loads Provides complete full-duplex visibility at or 0 Mbps without data stream interference or introducing a point of failure No IP address is needed for the Tap or monitoring device, enhancing monitoring security Compatible with Mid-Span Power over Ethernet (PoE) applications Redundant power ensures monitoring uptime Fully RoHS compliant Enhanced, Efficient Monitoring Active response capability increases Tap-based monitoring flexibility and efficiency Hardware switch provides a secure transition between passive mode (transmit only) and active mode (transmit/receive) for the Active Response Port Ease of Use LED indicators show redundant power, speed, link, and activity status DIP switches select auto-negotiation or fixed speed and duplexing settings for the Tap Front-mounted connectors support easy installation and operation Silk-screened application diagram illustrates all connections for easy deployment Optional 19-inch rack frames hold up to three Taps Tested and compatible with all major manufacturers monitoring devices, including protocol analyzers, probes, and intrusion detection/prevention systems Support Net Optics offers free technical throughout the lifetime of your purchase. Our technical support team is available from 8 am to 5 pm Pacific Time, Monday through Friday at +1 (408) 737-7777 and via email at ts-support@ netoptics.com. FAQs are also available on Net Optics website at www. netoptics.com.

/0 Port Aggregator Tap Unpacking and Inspection Carefully unpack the /0 Port Aggregator Tap w/active Response and check for damaged or missing parts. The Tap ships with the following: /0 Port Aggregator Tap w/active Response Two power supplies Two network cables One or two monitor cables Installation Guide You may have also ordered a one rack unit panel for mounting three Taps and an extended warranty. Carefully check the packing slip against parts received. If any part is missing or damaged, contact Net Optics' Customer Service immediately. Product Diagrams Power LEDs Network Ports A & B Monitor Port 1 A B 1 Port Aggregator with Active Response 2 1 www.netoptics.com LINK 0 ACT LINK 0 ACT LINK 0 ACT LINK ACT Figure 1: PA-CU-AR Front Panel Power LEDs Network Ports A & B Monitor Ports 1 & 2 A B 1 2 Dual Port Aggregator Tap with Active Response 2 1 www.netoptics.com LINK 0 ACT LINK 0 ACT LINK 0 ACT LINK 0 ACT Figure 2: PAD-CU-AR Front Panel

/0 Port Aggregator Tap DIP Switch Power DC Jacks 1 2 3 4 5 6 7 8 Figure 3: Rear Panel LED Indicators PWR 1/ PWR 2: Main and Redundant Power. If the Tap is deployed with both power supplies, both LEDs will illuminate when the Tap is plugged in. If an LED is off, this indicates that the corresponding power supply is not functioning. Additional Port Aggregator Tap LEDs are located in the upper left and right hand corners of the RJ45 connectors for Port A, Port B, Port 1 and Port 2 (PAD-CU-AR only). /0 Indicator: If the Port is set to Mbps, the LED illuminates orange. If the Port is set to 0 Mbps, the LED illuminates green. Link/Activity Indicators: If a good link is established, the LED illuminates a steady green. If there is current activity on this link, the LED flashes.

www.netoptics.com A B 1 2 /0 Port Aggregator Tap Application Diagrams: Memory Operation All traffic that passes through the Tap is sent to the monitoring device NIC on a first-in, first-out basis, including traffic that is temporarily stored in memory. (If two packets enter at the same time then one packet is processed while the other is stored briefly in memory, preventing collisions.) When there is a burst of data, traffic in excess of the NIC's capacity is sent to the Tap's memory. Up to one megabyte of data per side of the full-duplex stream can be stored in memory. Memory continues to fill until its capacity is reached, or the burst ends whichever comes first. In both cases, the Tap applies a first-in, first out procedure, processing stored data before new data from the link. If memory fills before the burst ends, the memory stays filled as the stored data is processed data that leaves the buffer is immediately replaced. If the burst ends before the memory fills, memory clears until the full megabyte of capacity is available, or until another burst in excess of the NIC's capacity requires additional memory. The following three diagrams illustrate a simple example of a 0 Mbps NIC moving from 80 percent utilization, to 140 percent utilization, then back to 80 percent utilization. If you have PA-CU-AR model, there is only one monitor port. State 1: Side A + Side B is less than or equal to 0% of the NIC's receive capacity. Example: On a 0 Mbps link, Side A is at 30 Mbps and Side B is at 50 Mbps. The NIC receives 80 Mbps of traffic (80% utilization), so no memory is required for the monitoring device NIC to process all full-duplex traffic. Side A Active Response Dual Port Aggregator Tap Router Side B Firewall Side A + Side B 1 Each using a single NIC, the monitoring devices both receive all combined traffic from Side A and Side B, including physical layer errors. Monitoring Device 1 Monitoring Device 2 Figure 4: 80% Utilization 6

www.netoptics.com A www.netoptics.com B 1 2 A B 1 2 /0 Port Aggregator Tap State 2: Side A + Side B becomes greater than 0% of the NIC's receive capacity. Example: There is a burst of traffic, so Side A is now at 90 Mbps while Side B remains at 50 Mbps. The NIC's utilization is at 140%, requiring the use of memory to help prevent data loss. Side A Active Response Dual Port Aggregator Tap Router Firewall The extra 40 Mbps of traffic is 2 stored in the 1 megabyte buffer for Port A. Memory continues to fill until the 1 megabyte capacity is reached, or the burst ends. (A separate 1 megabyte buffer is also available to handle a burst on Port B.) Memory Side B Side A + Side B Monitoring Device 1 Monitoring Device 2 1 Each using a single NIC, the monitoring devices both receive all combined traffic from Side A and Side B, including physical layer errors. Figure 5: 140% Utilization State 3: Side A + Side B is once again less than 0% of the NIC's receive capacity. Example: On a 0 Mbps link, Side A is again at 30 Mbps and Side B remains at 50 Mbps. The NIC's utilization is again at 80%. Side A Active Response Dual Port Aggregator Tap Router Firewall The Tap applies a first-in, first-out 1 process to all packets. Once the burst has ended and the NIC's utilization is again below 0 percent, the Tap first processes the packets that were stored in memory. As long as the NICʼs utilization remains below 0 percent, this process continues uninterrupted until the memory clears. Memory Side B Side A + Side B Monitoring Device 1 Monitoring Device 2 2 Once the memory has cleared, each monitoring device begins receiving new data directly from the link. Each using a single NIC, both monitoring devices receive all traffic from Side A and Side B, including physical layer errors. Figure 6: Return to 80% Utilization

/0 Port Aggregator Tap Cabling Guidelines Use straight-through cable to connect the Tap Ports to a Router or NIC. Use cross-over cable to connect the Tap Ports to Switches and Hubs. The Tap Ports Transmit on Pins 3 & 6 and Receive on Pins 1 & 2. Note: You must ensure that both Network Ports A and B match speed and duplex settings on your network devices. Connecting to the Network 1. Connect Network Port A to the appropriate network device following the cabling guidelines above. 2. Connect Network Port B to the appropriate network device following the cabling guidelines above. 3. Verify that the Tap Network Ports are cabled in-line between two devices. A B 1 2 Passive Dual Port Aggregator with Active Response www.netoptics.com 2 1 LINK 0 ACT LINK 0 ACT LINK 0 ACT LINK 0 ACT To network switch or router To network switch or router Figure 7: Connecting to the Network

/0 Port Aggregator Tap Connecting to the Monitoring Device(s) 1. Supply power to the Tap using the power supplies included with the unit. Two power supplies are included. The use of the second redundant power supply is optional. Note: The second power supply is available to support the flow of traffic to the monitoring device, in the event that the first power supply becomes unavailable. If the first power supply is unavailable, the second power supply will supply all power for the Tap. Even if no power is available to the passive Tap, network traffic flows uninterrupted. 2. Verify that the Power LEDs illuminate. PWR 1 illuminates when the first power supply is in use, and PWR 2 illuminates when the second power supply is in use. Both power supplies can be plugged into the Tap at the same time. 3. Connect Monitoring Port 1 to the appropriate port on the monitoring. device using a CAT5 RJ45 straight-through cable to monitor the full-. duplex link. 4. If you are installing model PAD-CU-AR, connect Monitoring Port 2 to the appropriate port on the monitoring device using a CAT5 RJ45 straightthrough cable to monitor the full-duplex link. A B 1 2 Passive Dual Port Aggregator with Active Response www.netoptics.com 2 1 0 LINK ACT 0 LINK ACT 0 LINK ACT 0 LINK ACT To monitoring device 1 To monitoring device 2 (96448) Figure 8: Connecting to Monitoring Device(s)

/0 Port Aggregator Tap DIP Switch Settings Switch Function Description 1 Turns Auto-negotiation ON or OFF. Factory default setting is Auto-negotiation. If turned ON, ports A, B, and C/D automatically negotiate the links. Positions 2 thru 8 are inactive. To manually configure ports A, B, and C/D, turn switch to the OFF position. Positions 2 thru 8 are active. 2 Set Port A Duplex ON for Half-Duplex; turn OFF for Full-Duplex 3 Set Port A Speed ON for Mbps; turn OFF for 0 Mbps 4 Set Port B Duplex ON for Half-Duplex; turn OFF for Full-Duplex 5 Set Port B Speed ON for Mbps; turn OFF for 0 Mbps 6 Set Port 1 (and 2) Duplex ON for Half-Duplex; turn OFF for Full-Duplex 7 Set Port 1 (and 2) Speed ON for Mbps; turn OFF for 0 Mbps 8 Active Response Turns Active Response ON or OFF AUTO NEGOTIATE A B Active Response C ON OFF HD FD 0 HD FD 0 HD FD ON 0 OFF 1 2 3 4 5 6 7 8 NOTE: To activate, push buttons UP. (This diagram shows all segments in the OFF position) Figure 9: DIP Switch Settings

/0 Port Aggregator Tap Active Response Tap FAQs Q: What types of active responses are supported? A: With an Active Response Dual Port Aggregator Tap, an administrator can transmit any type of Ethernet packet back into the original link, supporting all common types of active responses generated by intrusion detection systems, and by intrusion prevention systems deployed in passive mode. The most common response types are TCP resets, and firewall rule changes. While the Tap can support both types of responses, we advocate extreme caution in dynamically updating firewall rules due to the risk of disabling network services. Because most firewalls are managed out-of-band, however, it is unlikely that the Regeneration Tap will be part of a rule change scenario. Q: How are collisions avoided when active responses are transmitted back into the original link? A: On each side of the full-duplex link, there is a small buffer for traffic arriving from the network, and another small buffer for active response traffic arriving from the monitoring device. Traffic is released from this buffer pair on a first-in, first-out basis. If both sides of the buffer are empty and a packet originating from the monitoring device and a packet originating from the network arrive at the same time, priority is given to the network packet. 11

/0 Port Aggregator Tap Active Response Tap FAQs (Continued) Q: How much bandwidth is available on the Active Response Port? A: The average amount of bandwidth for active responses is determined by the average available capacity on the link. For example, on a 0 Mbps fullduplex link, if transmission from device A to device B averages 30 Mbps, and transmission from device B to device A averages at 50 Mbps, then there is an average capacity on the first side for 70 Mbps, and on the second side for up to 50 Mbps of active response traffic. At any particular point in time, actual capacity is determined by the size of the packets being transmitted and the gap between these packets. On a standard link with 64-byte network and active response traffic, the capacity at any point in time will be very close to the average capacity. (We do not recommend using the Tap on links with jumbo packets as these large up to 9K packets can fill the buffer and impact performance.) As the most common use for the Tap will be to inject TCP resets, which are standard 64-byte packets, it is unlikely that the transmissions from either side of the Active Response Port will exceed Mbps, even if many sessions are terminated in a short time frame. In our internal testing, we have therefore focused on Active Response Port performance at up to Mbps. Q: Does Active Response Port require the connected monitoring device to have an IP address? A: Yes, the connected monitoring device is required to have a MAC and IP address when the Active Response Port is operating in active mode. These are not required when this Port is set to passive mode. The Tap itself never has a MAC or IP address, regardless of how the Active Response Port is set. 12

/0 Port Aggregator Tap Specifications Environment Operating Temperature: 0 C to 55 C Storage Temperature: - C to 70 C Relative Humidity: % min, 95% max, non-condensing Power Power Supply Input: 0-240VAC, 0.5A, 47-63Hz Output: 12V, 1.5A Mechanical Dimensions: 1.125 high x 9.125 deep x 4.5 wide Cable Interface Copper Cable Type: 22-24 AWG unshielded twisted pair cable,...cat5/cat5e Link Distance Supported: 0 meters Connectors (2) RJ45, 8-pin connectors (network ports) (1) RJ45, 8-pin connector (PA-CU-AR monitor port) (2) RJ45, 8-pin connectors (PAD-CU-AR monitor ports) Certifications Fully RoHS compliant 13

/0 Port Aggregator Tap Limitations on Warranty and Liability Net Optics offers a limited warranty for all its products. IN NO EVENT SHALL NET OPTICS, INC. BE LIABLE FOR ANY DAMAGES INCURRED BY THE USE OF THE PRODUCTS (INCLUD- ING BOTH HARDWARE AND SOFTWARE) DESCRIBED IN THIS MANUAL, OR BY ANY DEFECT OR INACCURACY IN THIS MANUAL ITSELF. THIS INCLUDES BUT IS NOT LIM- ITED TO LOST PROFITS, LOST SAVINGS, AND ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OR INABILITY TO USE THIS PRODUCT, even if Net Optics has been advised of the possibility of such damages. Some states do not allow the exclusion or limitation of implied warranties or liability for incidental or consequential damages, so the above limitation or exclusion may not apply to you. Net Optics, Inc. warrants this Tap to be in good working order for a period of ONE YEAR from the date of purchase from Net Optics or an authorized Net Optics reseller. Should the unit fail anytime during the said ONE YEAR period, Net Optics will, at its discretion, repair or replace the product. This warranty is limited to defects in workmanship and materials and does not cover damage from accident, disaster, misuse, abuse or unauthorized modifications. If you have a problem and require service, please call the number listed at the end of this section and speak with our technical service personnel. They may provide you with an RMA number, which must accompany any returned product. Return the product in its original shipping container (or equivalent) insured and with proof of purchase. Additional Information Net Optics, Inc. reserves the right to make changes in specifications and other information contained in this document without prior notice. Every effort has been made to ensure that the information in this document is accurate. Net Optics is not responsible for typographical errors. THE WARRANTY AND REMEDIES SET FORTH ABOVE ARE EXCLUSIVE AND IN LIEU OF ALL OTHERS, EXPRESS OR IMPLIED. No Net Optics reseller, agent, or employee is authorized to make any modification, extension, or addition to this warranty. Net Optics is always open to any comments or suggestions you may have about its products and/or this manual. Send correspondence to. Net Optics, Inc.. 5303 Betsy Ross Drive. Santa Clara, CA 95054 USA. Telephone: +1 (408) 737-7777. Fax: +1 (408) 745-7719. Email: info@netoptics.com/internet: www.netoptics.com All Rights Reserved. Printed in the U.S.A. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language or computer language, in any form, by any means, without prior written consent of Net Optics, Inc., with the following exceptions: Any person is authorized to store documentation on a single computer for personal use only and that the documentation contains Net Optics' copyright notice. 14