FIRE RISK ASSESSMENT SW13 0HA



Similar documents
The terms hazard and risk are often used, which we define as the following:

UCL FIRE RISK ASSESSMENT POLICY& ARRANGEMENTS

FIRE SAFETY RISK ASSESSMENT

REGULATORY REFORM (FIRE SAFETY) ORDER Fire Risk Assessment. 145 Drury Lane Covent Garden London WC2B 5TA

How To Write A Fire Risk Assessment

For use by landlords of small premises Premises Address

Lee Baron FIRE RISK ASSESSMENT

Fire Safety Challenges and Solutions. Claire Guise Health and Safety Manager

For use by landlords of small premises Premises Address

1.1.4 The findings from Fire Risk Assessment must be incorporated into the FRAMS Action Plan to manage fire safety at each premise.

Fire Risk Assessment For Simple Premises

Fire Safety Risk Assessment Checklist for Residential Care Premises

UPP Residential Services Fire Risk Assessment

Action required (Please tick) If you answered YES, record Action Points at STEP 4

Fire Safety Risk Assessment

NEW FIRE SAFETY LEGISLATION

FIRE RISK ASSESSMENT WORKED EXAMPLE

Bastille Court 2 Paris Garden London SE1 8ND Telephone: Fax: training@thefpa.co.uk Web:

Fire Safety Log Book

Fire Risk Assessment Safety Checklist

1.0 APPOINTMENTS 2.0 FIRE RISK ASSESSMENTS

Grasshoppers Rugby Football Sports and Social Club. The Fire Risk Assessment

Fire precautions in dwellings. Private sector housing Providing homes building communities

Fire Evacuation Procedures Network Building, 97 Tottenham Court Road, London, W1

Fire Risk Assessment. John Revington

To promote and protect the private residential landlord. Fire Safety Logbook. Information. Advice. Support. Services START DATE:

Guidance on the use of Marquees, Tents and other Temporary Structures

St. Werburgh s. Fire,Smoke & Water Damage. Threats to Faith,Fabric &Future. Joseph A Gannon. FRIAI, MUBC(UCD).I.Eng.MIFire E

FIRE RISK ASSESSMENT

The Management of Asbestos containing Materials

Preventing arson in buildings

CITY OF LONDON SCHOOL FOR GIRLS FIRE SAFETY, PROCEDURE AND RISK ASSESSMENT POLICY

Fire Risk Assessment Report

Fire risk assessment a guide for businesses

Regulatory Reform (Fire Safety) Order A short guide to making your premises safe from fire

Guidance When Sub-Letting a Flat

1.1. EMERGENCY PROCEDURE On discovering a fire or being informed of an emergency;

FLA S FIRE SAFETY INITIATIVE

AFTRS Health and Safety Risk Management Policy

OAKPARK SECURITY SYSTEMS LIMITED. Health & Safety Policy. Requests or suggestions for amendment to this procedure

FIRE RISK ASSESSMENT PRINCIPLES A GUIDE FOR LICENSED PREMISES

Fire Alarms- Use of buildings when they are out of service

1. Fire Safety Policy and Responsibilities. Consult the Employer s Fire Safety Policy and establish responsibilities of staff for fire safety.

Fire Policy and Procedures. Cañada Blanch Spanish School

FIRE RISK ASSESSMENT

c. As mandated by law, facilities must obtain and maintain valid zoning permits as well as permits for intended use.

IFE Level 4 Certificate in Fire Science and Fire Safety (HL)

Proposed Residential Complex At Holding No. - 98, B.T. Road, Kolkata Developer Premier Mica Mining And Manufacturing Company

GUIDE TO CARRYING OUT A SUPERVISED FIRE EVACUATION DRILL

Fire safety advice for landlords

Guidance Document on SELECTION AND SPECIFICATION OF FIRE ALARM CATEGORY IN ACCORDANCE WITH BS

HAVEBURY HOUSING PARTNERSHIP

HEALTH & SAFETY BICS ULTIMATE GUIDE HEALTH SAFETY

Corporate Health and Safety Policy

Safety Systems Review Facilities Management Guidance and specification Version

Berkeley Castle. Occupant Fire Safety

St. John s University

Your responsibilities if you have an automatic fire alarm. A handy guide for owners and responsible persons

Fire Safety Requirements for Child Care Centre

RC44. for fire risk assessment of catering extract ventilation

Fire. The Fire Installers Mate. A guide to fire alarm systems design

Guidance for Electrical Contractors on Emergency Lighting Legislation

LINCOLNSHIRE FIRE AND RESCUE

PRACTICAL FIRE SAFETY GUIDANCE FOR EDUCATIONAL AND DAY CARE FOR CHILDREN PREMISES

FIRE RISK ASSESSMENT. The Workplace Fire Precautions Legislation

Fire Safety Policy. Fire Safety Policy: May 2011 Page 1 of 6. Version 1. Scope:

ESTABLISHMENT OF A NEW BUSINESS

ISLE OF MAN FIRE & RESCUE SERVICE FIRE PRECAUTIONS LOGBOOK. Website

Hotel Fire Safety for staff

Fire Risk Assessment for Simple Premises Guidance Notes

Corporate Health and Safety Policy

Contractor Safety Management

Five Star Occupational Health and Safety Audit Specification document 2013

Caravan Sites and Control of Development Act Permanent Residential Mobile Home Sites Licence Conditions

Walk around and identify the area to be assessed and look at what could reasonably be expected to cause harm.

Policy on the Management of Asbestos

NORTH BIRMINGHAM ACADEMY

EMERGENCY EVACUATION PLAN FOR LIFE AND FIRE SAFETY

Course of Construction Questionnaire

Abu Dhabi EHSMS Regulatory Framework (AD EHSMS RF)

Additional Guidance. for application to. HM Government Guide to Fire Safety Risk Assessment Residential Care Premises

Vendor Management Program

RESIDENTS FIRE SAFETY INFORMATION PACK

Emergency Procedures IF YOU DISCOVER A FIRE. Upon discovering a fire: the following steps are to be taken:

Recommendations to improve the safety of existing lifts

EVACUATION OF DISABLED PEOPLE (Document under constant review)

Fire Safety in High Rise Residential Blocks

NHSScotland Firecode Scottish Health Technical Memorandum 86 Fire Risk Assessment

Guidance on Provision of Fire Wardens

FIRE DETECTION AND ALARM SYSTEMS

FIRE SAFETY RECORD OF TESTS LOGBOOK

ASA HEALTH AND SAFETY POLICY

RESIDENTS FIRE SAFETY INFORMATION PACK

Workplace Fire Safety

ASBESTOS MANAGEMENT PLAN

Contents. 1. Introduction 1.1 Reason for this Guide Interpretation 1.3 Principles of Fire Safety 1.4 Legal Provisions 4

Transcription:

FIRE RISK ASSESSMENT at Carmichael Court Grove Road London SW13 0HA ON BEHALF OF Farrar Property Management Date of assessment: 14/01/2013 Recommended review date: January 2015

CONTENTS 1.0 INTRODUCTION 3 1.1 SCOPE OF ASSESSMENT 3 1.2 BENCHMARKING 3 1.3 LIMITATIONS 3 1.4 OVERALL RISK RATING 4 1.5 RECOMMENDED REVIEW 4 2.0 PROPERTY DETAILS 5 2.1 SUMMARY 5 2.2 PLANT / EQUIPMENT 6 2.3 SOURCES OF FUEL / IGNITION 6 2.4 OCCUPANTS AT RISK 6 3.0 FIRE SAFETY ARRANGEMENTS 7 4.0 ASSESSMENT OBSERVATIONS 9 4.1 SUMMARY 9 4.2 MANAGEMENT COMPLIANCES AND CONTROLS 11 4.3 FIRE HAZARDS / RISKS 13 5.0 OTHER RELEVANT INFORMATION 15 6.0 ACTION PLAN 16 6.1 MANAGEMENT COMPLIANCES AND CONTROLS 17 6.2 PRIORITY 1 FIRE HAZARDS / RISKS 18 6.3 PRIORITY 2 FIRE HAZARDS / RISKS 18 6.4 PRIORITY 3 FIRE HAZARDS / RISKS 18 Page 2 of 18

1.0 INTRODUCTION 1.1 SCOPE OF ASSESSMENT In accordance with the Regulatory Reform (Fire Safety) Order 2005, Tetra Consulting Limited was instructed to carry out a fire risk assessment of at on behalf of Farrar Property Management. The assessment was carried out by Richard Flatman who has been deemed competent to carry out fire risk assessments based on their skills, knowledge and experience. Key details about the assessment are as follows: Landlord1: Responsible person: Carmichael Court Freehold Limited Joe Starkey Assessment date: 14/01/2013 Person(s) consulted during inspection: Nobody Areas inspected: Areas excluded: All external common areas including stairwells. Areas demised to tenants. Roof (no access possible access ladder locked). 1.2 BENCHMARKING This assessment follows guidance provided in: HM Government guidance document(s) supporting the Regulatory Reform (Fire Safety) Order 2005 PAS 79: 2012 Fire Risk Assessment Guidance and Recommended Methodology Building Regulations (part B) BS9999 : 2008 Code of Practice for fire safety in the design, management and use of buildings Other relevant technical British and European standards. 1.3 LIMITATIONS The observations and recommendations made in this report relate to conditions and documentation seen during the inspection, and only in areas that were safely accessible as listed in 1.1 above. The risk assessor used professional expertise and judgement in making their recommendations. Assessments are open to individual interpretation however and an enforcement officer may hold a different view. Page 3 of 18

1.4 OVERALL RISK RATING Based on the conditions observed during the site visit, the overall risk of harm is deemed to be: LOW 1.5 RECOMMENDED REVIEW The Regulatory Reform (Fire Safety) Order 2005 requires that fire risk assessments are reviewed. Based on the conditions observed, it is recommended that this risk assessment be reviewed within: 2 years An earlier review should be carried out if: there is a significant change in layout or use significant changes are made to the installed fire safety equipment a fire occurs Page 4 of 18

2.0 PROPERTY DETAILS 2.1 SUMMARY Property usage: Property size: Residential - purpose built block 50 flats Date of construction: Pre 1991 Details of construction: Brick elevations with wooden floors and flat roof. Number of floors: Number of exits: Number of stairwells: Number of lifts: Ground and three upper floors. 1 main exit and one exit to rear. 4 external concrete staircases. None Car park details: Security measures: None Coded access panel. Electronic fob entry. Local Fire Authority: Fire loss experience: Means of escape: Other relevant information: London Fire and Emergency Planning Authority. None reported. The means of escape are provided by a number of external routes, each residential unit has access to an external walkway. All tenant entrance doors open on to external walkways. Page 5 of 18

2.2 PLANT / EQUIPMENT Plant/Equipment Type (s) Location Date of Last Service / Frequency Access gates Motorised Main entrance No records Electrical intake Mains Not seen No records External lighting Wall mounted Courtyard area No records Work equipment Vertical ladder 3rd floor to roof No records Specific Fire Equipment Provided Type (s) Location Date of Last Service / Frequency Fire doors Nominal Tenant entrances No records 2.3 SOURCES OF FUEL / IGNITION Sources of fuel identified: Sources of ignition identified: Furniture and fittings; Carpet; Building structure and fabric; Clothing; Food; Cardboard; Plastic; Refuse. Electrical power supply; cooking; Accidental; Arson. 2.4 OCCUPANTS AT RISK Total building occupancy: 1-150 Total number of employees / tenants: 1-130 Total number of visitors / members of public: Occupants identified at special risk: Note: all figures are approximate. 1-20 Sleeping residents. Possible children and/or elderly and infirm. Page 6 of 18

3.0 FIRE SAFETY ARRANGEMENTS Management of Fire Safety Overall, fire safety management at this property appears to be excellent. This judgement is based on the number of management controls that are in place (see section 4.2) and number of hazards / deficiencies observed (see section 4.3). A separate report (ref: L- 14352) detailing management compliance present within the managing agent organisation has also been completed and should be read in conjunction with this site specific risk assessment report. The report covers elements which apply across the property portfolio including: - fire policy and strategy; - arrangements for co-operation between parties and co-ordination of fire safety measures; - selection and control of contractors; - permit to work systems. Housekeeping and Fire Hazards (Sources of Fuel and Ignition) Overall, housekeeping standards at this property are considered to be excellent. The following areas were observed to be clear of obstruction and storage of combustible materials: stairwells; escape routes. Housekeeping standards are monitored monthly by the property manager. Refuse and waste is stored in the tenant demised areas. This is collected on a regular basis. Arson Threat and Security Measures The following security measures are in place to deter would-be arsonists: external lighting; door entry phone. Housekeeping and waste control in external areas is adequately controlled. Based on this, the risk of deliberate fire setting at this property appears to be no higher than usual, given the property s usage and location. Fire Detection and Warning Systems As this property is a purpose built residential block, with no internal common areas there is no requirement for an interconnected fire detection and warning system to be installed in this property. Emergency Lighting There is no emergency lighting installed in the common parts of this property. Article 14 of the Regulatory Reform (Fire Safety) Order 2005 requires that it be installed on all escape routes in all properties, except very simple ones with good natural / borrowed light available. See risk assessment section for details of locations to be covered. Fire Extinguishers As this is a residential property with no internal common areas, there is no requirement for extinguishers at this site. Fire Compartmentation Based on the areas that it was possible to access, the fire separation in this building appears to be adequate for its present use, with no issues Page 7 of 18

identified. The status of the doors to the residential flats could not be ascertained however. Means of Escape The means of escape at the property are described in section 2.1 of this report. Given the current usage and occupancy of the building, the means of escape including travel distances and corridor/staircase widths are considered adequate. The stairwells and escape routes are free from obstructions and stored items. The final exit doors can be opened easily without the use of a key and lead directly to areas away from the building. Emergency Plan An emergency action plan needs to be formulated for this property, based on a stay put policy. The person responsible for notifying the fire brigade of any fire is: the person discovering it. The plan needs to be communicated to all occupants and visitors Facilities for Fire and Rescue Service The fire and rescue service can access the property directly from the street. Page 8 of 18

4.0 ASSESSMENT OBSERVATIONS 4.1 SUMMARY The total number of non compliances and hazards contribute to a management rating for each property. Each action identified in the risk assessment is weighted as detailed in the table below to provide a total score. The total score provides a rating for the property and overall Fire Risk Management Rating: Risk Assessment Score Property Rating < 25 points Outstanding 26 50 points Excellent 51-75 points Good 76 100 points Satisfactory 101 150 points Poor > 150 points Unsatisfactory Non Compliances & Hazards Number Identified Weighting Total Non Compliances 3 10 30 Priority 1 0 25 0 Priority 2 0 5 0 Priority 3 1 1 1 Total Score 31 Based on the observations made on site, and the information provided to the consultant, the overall fire risk management at this property is Excellent Page 9 of 18

The following timeframes are suggested for resolving actions raised in this report. Report section Action required Action completed Management compliances Immediately Within 3 months Priority 1 hazards Immediately Within 1 month Priority 2 hazards Within 1 month Within 3 months Priority 3 hazards Within 3 months Within 6 months Page 10 of 18

4.2 MANAGEMENT COMPLIANCES AND CONTROLS All relevant fire safety management compliances and controls have been briefly assessed to determine whether they are compliant (C) or non-compliant (NC). Items that are outstanding from the previous assessment are with marked with an *. Requirement Relevant Legislation / Standard Observation Rating Action Required F01 Fire Risk Assessment Audit Regulatory Reform (Fire Safety) Order 2005. Fire (Scotland) Act 2005. Fire Safety Regulations (Northern Ireland) 2010. This audit meets the requirements of Article 9 of the Regulatory Reform (Fire Safety) Order 2005. C F03 Emergency Evacuation Plan Regulatory Reform (Fire Safety) Order 2005. Fire (Scotland) Act 2005. Fire Safety Regulations (Northern Ireland) 2010. No emergency evacuation plan in place. N Formulate a simple emergency evacuation plan and communicate to all tenants / relevant parties in writing. As a minimum, plan should include: whether there is a stay at home or evacuate policy; responsibility for contacting fire brigade; and the location of assembly point or place of ultimate safety. F09 Means of Escape Regulatory Reform (Fire Safety) Order 2005. Fire (Scotland) Act 2005. Fire Safety Regulations (Northern Ireland) 2010. The means of escape, including fire doors, are checked as part of a monthly property inspection regime. C Page 11 of 18

Requirement Relevant Legislation / Standard Observation Rating Action Required F17 Emergency Lighting Regulatory Reform (Fire Safety) Order 2005. Fire (Scotland) Act 2005. Fire Safety Regulations (Northern Ireland) 2010. Workplace (Health, Safety & Welfare) Regulations 1992. No emergency lighting installed at the property. N Emergency lighting is a legal requirement. Please refer to hazards section for recommended actions required to achieve compliance. E1 Inspection of Electrical Installations Electricity at Work Regulations 1989. IEE Regulations 17th Edition No record of electrical installations having been inspected in last five years (minimal power within common parts). N Verify that record exists and is up to date. If not, contact NICEIC registered contractor to undertake 5 year inspection of the common parts electrical installations and/or provide a copy of the completion certificate. Ensure certificate is kept up to date and is available for inspection. Page 12 of 18

4.3 FIRE HAZARDS / RISKS The objective of risk assessment is to systematically and numerically evaluate the likelihood/frequency of a potential hazard to cause harm, and the severity of that harm. The following definitions apply: Hazard: something with potential to cause harm Likelihood: the chance of a hazard being realised Frequency: how often people are exposed to a hazard Severity: the most likely consequence of a hazard being realised Risk: the combination of likelihood/frequency and severity Risk rating: a numerical and qualitative assessment of risk based on the multiplication of rankings of likelihood/frequency and severity Each assessment produces a numerical overall risk rating which can then be applied to categorising risks into order of priority for required action. SEVERITY 4 Single or multiple death 3 Major injury (as defined by RIDDOR) 2 Minor injury (more than 3 days off work) 1 Trivial injury (less than 3 days off work) LIKELIHOOD / FREQUENCY 3 Certain harm will occur / high or frequent exposure 2 Near certain harm will occur / medium or regular exposure 1 Harm seldom will occur / low or irregular exposure RISK RATING PRIORITY RISK RATING (severity x likelihood) 9-12 1 Substantial 4-8 2 Moderate 1-3 3 Trivial LIKELIHOOD 1 Low 2 Medium 3 High 1 Trivial injury 1 Trivial 2 Trivial 3 Trivial 2 Minor injury 2 Trivial 4 Moderate 6 Moderate SEVERITY 3 Major injury 3 Trivial 6 Moderate 9 Substantial 4 Single or multiple death 4 Moderate 8 Moderate 12 Substantial Page 13 of 18

Hazard reference: 2.L Hazard location(s): Hazard description: Sources of fuel: Sources of ignition: External walkways. No emergency lighting installed. This may cause serious injury and/or confusion in the event of an evacuation and the failure of the mains electrical power. N/A N/A People at risk: Contractors Employees Public Others Tenants Visitors 1-6 1-6 1-6 Existing controls: None. Risk Evaluation: Severity Likelihood Risk Rating Priority 3 1 3 3 Action required: Result of action: Monitoring and ongoing requirements: Emergency lighting to be installed as per the requirements of the Workplace (Health, Safety & Welfare) Regulations 1992 / Article 14 of the Regulatory Reform (Fire Safety) Order 2005. Emergency lighting units should be provided so that the following are illuminated: - stairways so that each flight has adequate lighting; - changes of floor level; - common external escape routes; - hazardous plant and equipment needing isolation in event of an emergency. When the above action has been implemented, the risk rating will be: Reduced Monthly tests to be carried out and records kept. Emergency lights to be maintained. Page 14 of 18

5.0 OTHER RELEVANT INFORMATION The client should record the location of any available relevant documents below, or append them to the back of this fire risk assessment. DOCUMENT LOCATION Site plans and drawings: Previous fire risk assessments: Tenants' fire risk assessments: Correspondence with local fire authority (including any enforcement notices): Other (please state): Page 15 of 18

6.0 ACTION PLAN The action plan which follows is a summary of all the actions generated in section 4. This should enable you to prioritise the allocation of time and resources when scheduling the remedial actions identified. To assist you, the following timetables are suggested: Report section Action required Action completed Management compliances Immediately Within 3 months Priority 1 hazards Immediately Within 1 month Priority 2 hazards Within 1 month Within 3 months Priority 3 hazards Within 3 months Within 6 months You should include a comment on every action generated. Remember: No action is still a viable action provided you can demonstrate that the action identified is not reasonably practicable to implement. This means that the cost of implementing the proposed action in terms of time, money and trouble far outweighs the benefit that will be achieved from it. Page 16 of 18

6.1 MANAGEMENT COMPLIANCES AND CONTROLS Ref No. Description Action Required/Recommendations REQUIRES IMMEDIATE ACTION E1 Inspection of Electrical Installations Verify that record exists and is up to date. If not, contact NICEIC registered contractor to undertake 5 year inspection of the common parts electrical installations and/or provide a copy of the completion certificate. Ensure certificate is kept up to date and is available for inspection. Action taken by: Comments: Date: F03 Emergency Evacuation Plan Formulate a simple emergency evacuation plan and communicate to all tenants / relevant parties in writing. As a minimum, plan should include: whether there is a stay at home or evacuate policy; responsibility for contacting fire brigade; and the location of assembly point or place of ultimate safety. Action taken by: Comments: Date: F17 Emergency Lighting Emergency lighting is a legal requirement. Please refer to hazards section for recommended actions required to achieve compliance. Action taken by: Comments: Date: Page 17 of 18

6.2 PRIORITY 1 FIRE HAZARDS / RISKS Ref No. Description Action Required/Recommendations None Identified 6.3 PRIORITY 2 FIRE HAZARDS / RISKS Ref No. Description Action Required/Recommendations None Identified 6.4 PRIORITY 3 FIRE HAZARDS / RISKS Ref No. Description Action Required/Recommendations 2.L External walkways. No emergency lighting installed. This may cause serious injury and/or confusion in the event of an evacuation and the failure of the mains electrical power. Emergency lighting to be installed as per the requirements of the Workplace (Health, Safety & Welfare) Regulations 1992 / Article 14 of the Regulatory Reform (Fire Safety) Order 2005. Emergency lighting units should be provided so that the following are illuminated: - stairways so that each flight has adequate lighting; - changes of floor level; - common external escape routes; - hazardous plant and equipment needing isolation in event of an emergency. Action taken by: Comments: Date: Page 18 of 18