2G-1.1.0, 200M-2.0.3, 200M-1.0.1



Similar documents
HARTING econ 3000 Introduction and features

Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)

IES-3080/3062 Series. Industrial 8-port managed Ethernet switch. Features. Introduction

User Guide. MC100CM MC110CS Fast Ethernet Media Converter. MC111CS MC112CS WDM Fast Ethernet Media Converter

EDR-G903 Series. Industrial Gigabit Firewall/VPN secure router. Introduction. Specifications. Industrial Ethernet Solutions

XPress-Pro SW Series Hardened Ethernet Switches Enabling Communication for the Demanding Industrial Environment

HARTING mcon 1000 Introduction and features

USER GUIDE. 2 Channel POTS Mux DIN Fiber Link System. Introduction SYSTEM INSTALLATION INFORMATION. The leader in rugged fiber optic technology.

Megapixall Security Tools & Accessories

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

4-Port 10/100Mbps with PoE + 1-Port 100FX Industrial Ethernet Switch Wide Temperature

USER S MANUAL. Ethernet 10/100 Transceiver Series DL221/DL221A

Copper to Fiber Stand-Alone Media Converter. Quick Installation Guide

Media Converters & Chassis

NS-205-IP67 5-Port Industrial 10/100 Mbps Ethernet Switch with IP67 Casing

Fiber s Role in the Video Security & Surveillance Network. Curt Carlson Product Manager Transition Networks

Fiber Optic Connectivity SECURITY SURVEILLANCE SOLUTIONS. ComNet Managed Ethernet Switches

HARTING econ 4000 Introduction and features

MICROSENS Media Converter 10/100/1000T to Gigabit Fiber

Media Converters & Chassis

Industrial 10/100/1000BASE-T to 100/1000BASE-X SFP Media Converter

Perle 10/100 Ethernet Media Converters

10/100/1000 Base-T to Gigabit Fiber Media Converter

4-Port 10/100Mbps with PoE + 1-Port 100FX Industrial Web Smart Switch

Your single source for network transmission solutions.

TrueAlarm Fire Alarm Systems

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

8-port 10/100Base-TX +2-port 100Base-FX Switch. User s Guide

8-Port PoE Network Switch

USER MANUAL MODEL 2300M SERIES. OpticLink Ethernet Media Converters (2300M, 2310M, 2311M, & 2312M)

The Most Complete Line of Media Converters in the Industry

M7250P. PoE Powered. Gigabit Ethernet Media Converter 1000BASE-TX TO 1000BASE-SX/LX. Installation Guide

PoE+ Extender Switch User's Manual. Rev W

4-Port 10/100Base-TX with PoE + 1-Port BNC / RJ-11 Industrial Ethernet Extender

Gigabit Switching Ethernet Media Converters - Product User Guide

MOXA EtherDevice Switch

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

FlexPoint T1/E1 Copper to Fiber Line Driver

G-TAP A Series // Data Sheet

IMC-101 Series Hardware Installation Guide

ConneXium Ethernet Switches TCSESU0 F N0 Quick Reference Guide

F2400 FOM II Series Fiber Optic Modem Technical Manual

DES-1005P 5-Port 10/100Mbps with 1-Port PoE Unmanaged Switch

Gigabit Ethernet: Architectural Design and Issues

Cisco MFE and MGE SFP Transceivers Cisco Small Business Network Accessories

Prisma Optical Media Converters Industrial Ethernet 10/100 Switching Mini Media Converters

ISIO 200. Binary Input/Output (I/O) Terminal with IEC Interface

c o m m u n i c a t i o n n e t w o r k s

DeltaV Control Network Hardware

alpha DSL WTM HS Instructions for use ADSL modem alpha DSL WTM HS

Moxa PoE Media Converter

Fiber Optics and Liquid Level Sensors Line Guide

Provides one channel for Ethernet over existing

Manageable 10/100/1000 Mbs Ethernet Modular Multi-Media Switch

FlexDSL MiniFlex. SHDSL.bis Up to 30Mbps Ddd. Ethernet. Features. Possible Applications

FCC COMPLIANCE STATEMENT

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Impact of Power-over-Ethernet (PoE) on Industrial-based Networking

- Monitoring Array: a seismic or infrasound array, including from 1(4) to 20 Remote Elements (RE) and one Central Recording Facility (CRF).

Gigabit Ethernet Copper-to-Fiber Converters

MICROSENS. Installation Switch with PoE (5x10/100Base-TX) and fiber uplink (1x100Base-FX) General. Features

Technology Solution Guide. Deploying Omnitron PoE Media Converters with Aruba Access Points and AirMesh Routers

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Power over Ethernet (PoE)

SHEET. Skorpion Managed Ethernet Switch Series. EISK8M Series

Perle Fast Fiber to Fiber. Media Converters

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

Rack mounted telephone- and leased line modem for industrial applications

4 Ports + 3 SFP Gigabit Smart Switch Use Manual. Ver.A0

1Industrial Ethernet Switch

Optimux-134, Optimux-125

IKS PoE Series. 24+4G-port Gigabit modular managed PoE+ Ethernet switches. Introduction. Industrial Ethernet Solutions. Features and Benefits

Application. Benefits. Contact us. Solution for Indoor TETRA coverage. TETRA/TETRAPOL Repeater RF/OF High Power. To ensure TETRA coverage everywhere

PROFINET Diagnostics Software and Tools

Supports O-Ring (recovery time < 30ms over 250 units of connection) and MSTP(RSTP/STP compatible) for Ethernet

USER MANUAL. PingBrother EPIW104 managed passive poe switch & IP watchdog

HES-3106-RF Series Managed CPE Switch

2-Pair. Managed SHDSL Ethernet Extender. User s Manual

INTRODUCTION TO MEDIA CONVERSION

My first Hirschmann: The SPIDER family of switches.

Perle 10/100/1000 Ethernet Media Converter Module

Optimux-134, Optimux-125

Ethernet over Copper Transmission Extenders

GEU Port Gigabit Switch

Ethernet/IEEE evolution

Terminal and Dimension

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no

3Com Transceivers OVERVIEW. Standards-based flexible Ethernet connections KEY BENEFITS

Expert Line Managed Industrial Switch with M-Ring Function 16x 10/100 Base-TX, 2x 10/100/1000Base-T (100/1000 Base-X SFP Ports)

EDS-G512E-8PoE-4GSFP Series 12G-port full gigabit PoE+ managed Ethernet switches

IEEE 802.3af 4-Port Power over Ethernet Injector Hub POE-400. User s Manual

FOMi-E3, FOMi-T3 E3, T3, and HSSI Manageable Fiber Optic Modems

5-port 10/100Base-TX Industrial Switch (314500) User s Guide

Power over Ethernet technology for industrial Ethernet networks

16x10/100/1000Base-T(X) ports and 8x100/1000Base-X, SFP socket

Perle Gigabit Fiber to Fiber Media Converters

Network Design. Yiannos Mylonas

High Speed Ethernet. Dr. Sanjay P. Ahuja, Ph.D. Professor School of Computing, UNF

Transcription:

Unmanaged PoE Switches and Media Converters of LAN-BUS System, 200M-2.0.3, SWITCH* MEDIA CONVERTER* RACK IP65 I Bus/ star topology I MM/SM universal I Overvoltage protections I Working temperature 40 +70 C I PoE***/PoE+**support Switches LAN-BUS ORDERING NAME CODE SUPPLY 200M-1.0.3-BOX--PoE 1-753-225 48VDC/24VAC*** 200M-1.0.3-IP65--PoE 1-753-825 48VDC/24VAC*** 200M-1.0.3-RACK--PoE 1-753-565 RACK/3U-SU(PoE) 200M-1.0.3-BOX--PoE 1-753-224 48VDC/24VAC*** 200M-1.0.3-IP65--PoE 1-753-824 48VDC/24VAC*** 200M-1.0.3-RACK--PoE 1-753-564 RACK/3U-SU(PoE) 200M-2.0.3-BOX-W6-PoE 1-752-226 48VDC/24VAC*** 200M-2.0.3-IP65-W6-PoE 1-752-826 48VDC/24VAC*** 200M-2.0.3-RACK-W6-PoE 1-752-566 RACK/3U-SU(PoE) Media converters LAN-BUS ORDERING NAME CODE SUPPLY -BOX--PoE 1-750-225 48-56VDC/24VAC** -IP65--PoE 1-750-825 48-56VDC/24VAC** -RACK--PoE 1-750-565 RACK/3U-SU(PoE) -BOX--PoE 1-750-224 48-56VDC/24VAC** -IP65--PoE 1-750-824 48-56VDC/24VAC** -RACK--PoE 1-750-564 RACK/3U-SU(PoE) -BOX--PoE 1-851-225 48-56VDC/24VAC** -IP65--PoE 1-851-825 48-56VDC/24VAC** -RACK--PoE 1-851-565 RACK/3U-SU(PoE) -BOX--PoE 1-851-224 48-56VDC/24VAC** -IP65--PoE 1-851-824 48-56VDC/24VAC** -RACK--PoE 1-851-564 RACK/3U-SU(PoE) **holder DIN35-LOCK for mounting to DIN35included with BOX modification **PoE+ standard IEEE 802.3at-2009 max. 25,5W ***PoE standard IEEE 802.3af max. 15,4W LAN-BUS 200Mbps - bus topology 200M-1.0.3 200M-2.0.3 200M-2.0.3 200M-2.0.3 200M-2.0.3 LAN-BUS 200Mbps point-to-point LAN-BUS 2Gbps point-to-point LEND 1x MM or SM fiber UTP Cat5e or higher twist Cat3 or higher www.metel.eu 10/10 1/11

LAN-BUS -use of system Industrial unmanaged switches and converters LAN-BUS represent an integrated system of devices suitable especially for extensive CCTV and security systems. Overvoltage protections of inputs and outputs enable use of LAN-BUS in both industrial and outdoor environment. When using METEL supply units of SU, ML or TRF series or supplying the switches from 19" racks RACK/3U there is a 5-year guarantee on switch damage up to the level of printed circuit interruption (see terms and conditions All Inclusive Warranty). MM / SM universalopticalports withwdm All optical ports on 2G series devices can be universally used for both MM and SM fibers in the range of 9/125µm to 62.5/125µm. Optical ports are equipped with integrated wavelength division multiplexer technology (WDM). The optical ring/connection is then made up of only one SM or MM fiber. Parameter Value Unit Note Optical power (2G) 9... 3 dbm Sensitivity (2G) 22 dbm Optical power (200M) 14 to 8 / 10 to 0 dbm SM / MM Sensitivity (200M) 31 / 28 dbm SM / MM Optical fibers 1x SM 9/125 - SC connectors µm max. 20 km between components 1x MM 50(62.5)/125 - SC con. µm max. 2 km between components Wavelengths 200M-2.0.3-...W6 PORT 4: Tx: 1310 / Rx: 1550 nm 200M-2.0.3-...W6 PORT 5: Tx: 1550 / Rx: 1310 nm 200M-1.0.3-... Tx: 1310 / Rx: 1550 nm 200M-1.0.3-... Tx: 1550 / Rx: 1310 nm -... Tx: 1310 / Rx: 1550 nm -... Tx: 1550 / Rx: 1310 nm -... Tx: 1310 / Rx: 1550 nm -... Tx: 1550 / Rx: 1310 nm Safety WARNING: converters contain laser sources of class 1 according to EN 60825-1-1 PoE support All the FE ports of LAN-BUS switches support standard IEEE 802.3af for supplying of end devices up to 15.4W of power. PoE+ support FE/ ports of media converters LAN-BUS support standard IEEE 802.3at-2009 for supplying of end devices up to 25.5W of power. Overvoltage protections Every ethernet port and supply input is equipped with overvoltage protection. See the table left below. Check the table right below whether it is necessary to use additional overvoltage protection of class D according to the IEC 61643-1 standard for all inputs in outdoor environments. 230VAC OVP 230/48VDC Fast ethernet Optoports OVP Type FE-UTP ports -UTP ports Supply input 200M-2.0.3 1000A 8/20µs - 2x1500 W (10/1000µs) 200M-1.0.3 1000A 8/20µs - 2x1500 W (10/1000µs) 30A 8/20µs - 2x1500 W (10/1000µs) - 30A 8/20µs 2x1500 W (10/1000µs) Type FE-UTP ports -UTP ports Supply input 200M-2.0.3 no - yes 200M-1.0.3 no - yes yes - yes - yes yes Working temperature 40 +70 C Every LAN-RING switch is made up of parts with min. temperature range of 40 to +85 C and passive cooling (without ventilators). 40 C +70 C www.metel.eu 2/11

Warranty ALL INCLUSIVE The warranty applies to all defects and faults of the Device(s) caused by excessive voltage except for destructive damages. The damages are not considered destructive if the Device is in such state that it can be repaired by replacement of one or more parts of the Device. The destructive damages are deemed to be damage to printed circuits (interruption of circuit, burnt soldering pads) disallowing repair of the Device unless replacing the printed circuit or using wire crossovers. In order to obtain this warranty, the following conditions should be met: 1. The Supplier's employees carry out installation inspection with reference to meeting recommended procedures of mounting and setting of converters. After the inspection and removal of eventual defects the Supplier issues a certificate confirming 60 months ALL INCLUSIVE guarantee. In case of impossibility of direct inspection for security reasons (hidden obejcts) or for object's inaccessibility it is possible to issue the certificate confirming 60 months ALL INCLUSIVE guarantee based on project documentation. The Supplier retains the right not to issue the certificate in case of impossibility of inspection in the location of installation. 2. When installing the Device(s) in lightning protections zones ZBO 0A, ZBO 0B according to EN 62305, the Device(s) shall be fed from the Supplier's power sources with class D overvoltage protections according to IEC61643-1, i.e. TRF-24...H or SU-230/ 4870H. When installing the Device(s) in lightning protections zones ZBO 1, ZBO 2 according to EN 62305, the Device(s) shall be fed from the Supplier's power sources or 19" racks BREAK. 3. When installing the Device(s), the minimum distances between the power and data cables shall be maintained, according to the applicable standards valid at the time of installation. 4. When installing the Device(s) in the outdoor environment IP56 modifications in original Al covers or BOX modifications placed in steel switchboards shall be used. Therefore, the warranty does not apply to Device(s) installed in outdoor environment in plastic cases. Plastic cases may be used only for indoor installations without direct sun rays at the Device(s) and in underground premises, such as mines, hydroelectric 40...to +50 C. 5. The Device(s) shall be earthed according to the applicable standards. In case of any complaint about damaging the Device(s) by overvoltage, the Supplier has the right to require the Device(s) to be provided with additional overvoltage protections. If the Buyer fails to provide the Device(s) with such protections, only the standard 60-month warranty applies (i.e. the warranty not including the damage to the Device(s) by overvoltage). Electric Parameters MTBF > 1.200.000 Hours MTBF was calculated on 1 st June 2009 according to the formula: MTBF=H/F H=total number of running hours of all switches sold F=number of failures Warranty 5 years incl. excessive voltage Parameter Value Unit Note LAN (UTP) Supported formats FE UTP ports: 10BaseT, 100BaseTx UTP ports: 10BaseT, 100BaseTx, 1000BaseTx Overvoltage protection see previous page Relay output Max. load 1x change-over contact (media converters) Max. 60VAC 1A max. 62.5VA Max. 60VDC 0.4A max. 30W Activation Loss of optical signal Loss of communication on UTP port Loss of supply Loss of redundant supply Power consumption Max. 4 VA without PoE Protections overvoltage/ current 2x 1.5 kw (10/1000µs) Environment Operational range 40...+70 ºC temp. of environment Certification TÜV The producer retains the right to change any technical parameters without previous announcement. www.metel.eu 3/11

Topology LAN-BUS Topology LAN-BUS 200Mbps enables, using one MM or SM fiber, interconnection of tens or hundreds of devices (cameras, sensors, s,...). When designing a network we recommend: 1. allowing for 20% system reserve, i.e. max. 80Mbps for each direction. The processors used in the devices enable use of LAN-BUS switches and media converters in systems with video and audio signal transmission (CCTV, VoIP,..). Max. data flow on200m LAN-BUS max. 100* Mbps max. 100* Mbps 1x SM (MM) fiber *Max. recommended load is 80% 2. attending to correct interconnection of optical ports. See the pictures below and the table on the following page. Model connection of one LAN-BUS bus 200M-2.0.3 200M-2.0.3 200M-2.0.3 200M-2.0.3 200M-1.0.3 Model connection of two LAN-BUS buses 200M-2.0.3 200M-2.0.3 200M-2.0.3 200M-2.0.3 200M-1.0.3 200M-2.0.3 200M-2.0.3 200M-2.0.3 200M-2.0.3 200M-2.0.3 200M-1.0.3 Model connection of LAN-BUS media converters in star topology switch www.metel.eu 4/11

Unmanaged PoE switches 200M-2.0.3 2x FO 200Mbps 3x FE ORDERING NAME SUPPLY with SUPPLY without PoE 200M-2.0.3-BOX-PoE 48-53 VDC 10-53 VDC / 10-30VAC 200M-2.0.3-RACK-PoE* 48-53 VDC 10-53 VDC / 10-30VAC 200M-2.0.3-IP65-PoE 48-53 VDC 10-53 VDC / 10-30VAC * supply of RACK cards with PoE only in 19" racks BREAK-RACK/PoE-100, BREAK-RACK/PoE-300, BREAK-RACK/PoE-500 PWR power supply indication LINK - connected fiber detection ACT - activity detection P5 - optical port 200M LAN-BUS Tx - 1550nm / Rx - 1310nm P4 - optical port 200M LAN-BUS Tx - 1310nm / Rx - 1550nm P1...P3 Ethernet 10/100 BASE-T POE ports - DUPLEX/COLLISION ACT - ACTIVITY 123456 ON --- spare P1...P3 - PoE OK DIP switch 6 - reserved 5 - reserved 4 - reserved 3 - PoE activation on P3 2 - PoE activation on P2 1 - PoE activation on P1 200M-2.0.3 200M-2.0.3 200M-2.0.3 200M-2.0.3 200M-1.0.3 www.metel.eu 5/11

Unmanaged PoE switches 200M-1.0.3 1x FO 200Mbps 3x FE ORDERING NAME SUPPLY with PoE SUPPLY without PoE 200M-1.0.3-BOX-PoE 48-53 VDC 10-53 VDC / 10-30VAC 200M-1.0.3-RACK-PoE* 48-53 VDC 10-53 VDC / 10-30VAC 200M-1.0.3-IP65-PoE 48-53 VDC 10-53 VDC / 10-30VAC * supply of RACK cards with PoE only in 19" racks BREAK-RACK/PoE-100, BREAK-RACK/PoE-300, BREAK-RACK/PoE-500 PWR power supply indication LINK - connected fiber detection ACT - activity detection P4 - optical port 200M LAN-BUS : Tx - 1310nm / Rx - 1550nm : Tx - 1550nm / Rx - 1310nm P1...P3 Ethernet 10/100 BASE-T POE ports - DUPLEX/COLLISION ACT - ACTIVITY 123456 ON --- spare P1...P3 - PoE OK DIP switch 6 - reserved 5 - reserved 4 - reserved 3 - PoE activation on P3 2 - PoE activation on P2 1 - PoE activation on P1 200M-2.0.3 200M-2.0.3 200M-2.0.3 200M-2.0.3 200M-1.0.3 www.metel.eu 6/11

Unmanaged PoE+ media converters 1x FO 200Mbps 1x FE ORDERING NAME SUPPLY with PoE(+) SUPPLY without PoE -BOX-PoE 48(56) VDC 10-60 VDC/ 10-30VAC -RACK-PoE* 48(56) VDC 10-60 VDC/ 10-30VAC -IP65-PoE 48(56) VDC 10-60 VDC/ 10-30VAC * supply of RACK cards with PoE only in 19" racks BREAK-RACK/PoE-100, BREAK-RACK/PoE-300, BREAK-RACK/PoE-500 Optical port 200M LAN-BUS : Tx - 1310nm / Rx - 1550nm : Tx - 1550nm / Rx - 1310nm SPEED indicates transmission speed of optical port On - 1000Base-X Off- 100Base-FX LINK/ACT indicates the state of fiber connection, event. by blinking activity of data transmission 10/100 BASE-T POE+ port - DUPLEX/COLLISION ACT - ACTIVITY PoE Indication ON - DIP5 OFF POE is off - DIP5 ON PoE is on OFF - insufficient supply for PoE Blinking - 1s interval searching for PoE device - fast failure on PoE device COM N.C. N.O. 123456 ON PWR ON - supply Blinking - relay activation indication, see DIP ALARM RELAY COMMON common contact N.C. - NC contact of output relay N.O. - NO contact of output relay The method of relay activation is set by closing one or more switches DIP1 to 5. When potential free only COM and NO are connected (closed). When connected to power COM and NC are connected (closed).(inactive state) When the alarm is activated COM and NO are connected (closed), seed DIP setting. DIP switch (restart needed after any changes) 6 - reserved 5 - switches on/off PoE on UTP port 4 - switches on/off main supply status check. Relay is activated by drop of the main supply below 10/44V (without/ with PoE). 3 - switches on/off redundant supply status check. Relay is activated by drop of the redundant supply below 10/44V (without/with PoE). 2 - switches on/off optical port connection status check. Relay is activated by loss of connection on optical port. 1 - switches on/off UTP port connection status check. Relay is activated by loss of connection on UTP port. switch www.metel.eu 7/11

Gigabit unmanaged PoE+ media converters 1x FO 200Mbps 1x ORDERING NAME SUPPLY with PoE(+) SUPPLY without PoE -BOX-PoE 48(56) VDC 10-60 VDC/ 10-30VAC -RACK-PoE* 48(56) VDC 10-60 VDC/ 10-30VAC -IP65-PoE 48(56) VDC 10-60 VDC/ 10-30VAC * supply of RACK cards with PoE only in 19" racks BREAK-RACK/PoE-100, BREAK-RACK/PoE-300, BREAK-RACK/PoE-500 Optical port 2G LAN-BUS : Tx - 1310nm / Rx - 1550nm : Tx - 1550nm / Rx - 1310nm SPEED - indicates transmission speed of optical port On - 1000Base-X Off- 100Base-FX LINK/ACT indicates the state of fiber connection, event. by blinking activity of data transmission 10/100/1000 BASE-T POE+ port - DUPLEX/COLLISION ACT - ACTIVITY PoE Indication ON - DIP5 OFF POE is off - DIP5 ON PoE is on OFF - insufficient supply for PoE Blinking - 1s interval searching for PoE device - fast failure on PoE device COM N.C. N.O. 123456 ON PWR ON - supply Blinking - relay activation indication, see DIP ALARM RELAY COMMON common contact N.C. - NC contact of output relay N.O. - NO contact of output relay The method of relay activation is set by closing one or more switches DIP1 to 5. When potential free only COM and NO are connected (closed). When connected to power COM and NC are connected (closed).(inactive state) When the alarm is activated COM and NO are connected (closed), seed DIP setting. DIP switch (restart needed after any changes) 6 - reserved 5 - switches on/off PoE on UTP port 4 - switches on/off main supply status check. Relay is activated by drop of the main supply below 10/44V (without/ with PoE). 3 - switches on/off redundant supply status check. Relay is activated by drop of the redundant supply below 10/44V (without/with PoE). 2 - switches on/off optical port connection status check. Relay is activated by loss of connection on optical port. 1 - switches on/off UTP port connection status check. Relay is activated by loss of connection on UTP port. switch www.metel.eu 8/11

Dimensions of RACK modifications Dimensions of IP65 modifications 290 3Ud 93 Switches 3 slotsd Media converters 250 84 144 Switches 200M-2.0.3 Media converters 3Ud 2 slotsd 159 Al casting www.metel.eu 9/11

109.00 Catalogue for Designers Installation of BOX modifications to flat surface and basic dimensions Media converters Switches 119.00 119.00 145.00 175.00 30.00 60.00 109.00 www.metel.eu 10/11

116 Catalogue for Designers Installation of BOX modifications to DIN35 rail Media converters Switches 109 145.00 175.00 60.00 109.00 37.00 REVISIONS: 201101 - new AL boxes www.metel.eu 11/11