Air Conditioning & Heat Pump Products



Similar documents
SANYO Air Conditioners & Heat Pumps

Air C r Conditioning & H g & Heat Pu at Pump Pro Produc u ts Revised Aug. 08

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

AIR CONDITIONING and HEAT PUMP PRODUCTS

DUCTLESS MINI-SPLITS SINGLE & MULTI-ZONE HORIZONTAL AIR CONDITIONERS PORTABLE UNITS FREE MATCH COMPONENTS

york air-conditioning products Residential & VRF News 2015

ECO-AIR AIR CONDITIONING

AIR CONDITIONING & HEAT PUMP PRODUCTS

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI

FTXS. Wall Mount Heat Pump or Cooling Only

2010 Duct-Free Splits Line Card

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. ELECTRICAL SCHEMATIC DIAGRAM EXPLOSION VIEW 16 6

AIR CONDITIONING and HEAT PUMP PRODUCTS

Ductless Systemss A COMFORTABLE, CONVENIENT SOLUTION BUILT TO A HIGHER STANDARD. READ ONLY

Ductless Mini-Split Systems. Comfort... where you need it, when you need it

innovative comfort solutions

Air Conditioning & Heat Pump Products Technical Training

FTQ. Daikin Inverter Ducted Heat Pump

Heat Pump Product Brochure 2015/2016. Premier Series Hi-Wall Split Systems. Everyday Comfort

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit

Gree Solar Hybrid Hi Wall Inverter Air Conditioner

HIGH-EFFICIENCY DUCTLESS INDOOR COMFORT

USER S MANUAL HSC-24A

Inverter Air Conditioning for Light Commercial Use

Residential and Light Commercial Air Conditioning Systems

Duct Free Split Air ConditionerS

LG Duct-Free Split Systems Product Overview. LG comfort solutions that you never thought possible

-~ available. Power consumption during operation is substantially less than that of lower rated

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

PRODUCT CATALOG. Indoor Units

REMOTE CONTROL MANUAL

SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS

FHQ. Ceiling Suspended Heat Pump or Cooling Only

OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump

Ductless Heat Pumps. Gary Nordeen January

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

1116, Suenaga, Takatsu-ku, Kawasaki , Japan

emura Form. redefined.

Unico Inverter. Unique and efficient.

Technology that works fast. Hi-Wall Split Systems

USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

PORTABLE AIR CONDITIONER

More than Air Conditioning. Catalogue 2004/2005. Air Conditioning Program R 407C R 410A

DAIKIN DUCTLESS HEATING AND COOLING SYSTEMS ABSOLUTE COMFORT BEGINS AT HOME.

DUCTED AIR CONDITIONING SOLUTIONS

To suit Daikin FDY "F" Series and FD "F" Series. (and other models incorporating BRC1B62/52 Remote Controller)

Mini-Split Air Conditioners and Heat Pumps for Residential and Light Commercial Applications

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

m-series Ultimate comfort where it matters most Mseries.MrSlim.ca PRODUCT CATALOGUE

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM EXPLOSION VIEW 12 6.

OWNER S MANUAL VMH 09/12/18/27/36 InverterFlex

LG Air conditioning Company Multi V Water Ⅱ. Air Conditioning Academy

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Glossary of Heating, Ventilation and Air Conditioning Terms

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW AOU12RLFW AOU15RLS

Comfort... where you need it, when you need it. Ductless Mini-Split Systems

FBQ. DC Duct Heat Pump or Cooling Only

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

DESIGN & TECHNICAL MANUAL

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

For Residential & Light Commercial Applications. 4 Ton 8 Zone Multi Split Heat Pump System

SERVICE MANUAL. Room Air Conditioner Multi Split Wall-Mounted Type Indoor. FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2

air conditioners how to choose a cooling system

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

Residential and Light Commercial Air Conditioning Systems

Air Movement. Heaters Desk Fans Wall Fans Pedestal Fans Ceiling Fans Extractor Fans Hand Dryers Air Conditioners. Pg

Monozone/Multizone (QH8,NH7A,NH6A,NH5,QH5) Summit (WX8)(FX8)(DH7A)(FH6)(YH6)(YH5A) Bigflow (G4,GH4) Technical Catalogue

Si10-417_C. Pocket Manual. Service Diagnosis SPLIT & MULTI

SINGLE PACKAGE VERTICAL AIR CONDITIONERS

FCQ. Roundflow Cassette Heat Pump or Cooling Only

Ducted and Duct-Free Cooling and Heating Solutions for all your Construction Needs R-410A INVERTER

Pioneer in sustainability

IR410AI. The flexible solution. Simple, one touch control

FOXAIR 60/50 ALL MODELS

FULL DC INVERTER SYSTEMS

DUCT TYPE AIR CONDITIONER

Ductless Heat Pumps for Passive Houses

WALL MOUNTED SPLIT TYPE AIR CONDITIONER

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL AW64AL /05

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

SiBE D-Series / E-Series. [Applied Models] Inverter Multi : Cooling Only Inverter Multi : Heat Pump

Operating Instructions Split System Air Conditioner

Model: AC-S13CG x 2. Model No: AC-S13CGx2.doc Version 1.0

LG AIR CONDITIONING SYSTEMS

Single Package Vertical Air Conditioners. Vert-I-Pak

DERON Air/Water Swimming pool Heat Pump. CY/DY series for Heating/Cooling. Description

Contents. Part 1 General Information Part 2 Outdoor Units Part 3 Installation Part 4 Troubleshooting 73

Hot Water. Heat pump water heaters. Residential and Commercial R410a

System. SERVICE MANUAL R410A MODEL : ARNU Series URNU Series

Trane Ductless Systems. Get comfortable with a smart solution. READ ONLY

Portable Air Conditioner

Instruction manual for Firstline FCS12000CH

YOUR CONDITIONS! units carry a 5-year Warranty for the compressor and for all parts of the unit. ) New Technologies

floater imports DF169 ECO AIR COOLER EVAPORATIVE AIR COOLER WITH IONIZER USER S MANUAL

ADVANCED ZONING CAPABILITIES

CLOSE CONTROL SYSTEM. PFD series provide you with highly reliable computer room cooling system. High Reliability

Hitachi Air Conditioning. Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE

Celxia. a s. Artcool uses state-of-the art technology to assure customer satisfaction.

Transcription:

Air Conditioning & Heat Pump Products Preliminary Revised April 06

SANYO Air Conditioners & Heat Pumps Btu/h 9,000 12,000 18,000 24,000 26,000 30,000 36,000 42,000 Type Standard Low Ambient Standard Low Ambient Standard Low Ambient Standard Low Ambient Standard Low Ambient Standard Low Ambient Standard Low Ambient Standard Low Ambient MODEL (System) 09KS71 09KLS71 12KS71 12KLS71 18KS72 18KLS72 24KS72 24KLS72 24KS62R 24KLS62R 26K72R 26T72R 26X72R 26U72R 30K72R 36K72R 36T72R 36X72R 36U72R 42T72R 42X72R Wall Mounted KS0971 KS1271 KS1872 KS2472 KS2462R KH2672R KH3072R KH3672R Suspended TH2672R TH3672R TH4272R AIR CONDITIONER Recessed Concealed Duct XH2672R UH2672R XH3672R UH3672R XH4272R Outdoor MODEL (System) 09KHS71 12KHS71 18KHS72 24KHS72 for KS2462R C2462R CL2462R for KH2672R,TH2672R, XH2672R,UH2672R C0971 CL0971 C1271 CL1271 C1872 CL1872 C2472 CL2472 C2672R C3072R C3672R C4272R 26KH72R 26TH72R 26XH72R 26UH72R 30KH72R 36KH72R 36TH72R 36XH72R 36UH72R 42TH72R 42XH72R Wall Mounted KHS0971 KHS1271 KHS1872 KHS2472 KH2672R KH3072R KH3672R HEAT PUMP WITHOUT HEATER Suspended Recessed Concealed Duct TH2672R XH2672R UH2672R TH3672R XH3672R UH3672R TH4272R XH4272R Outdoor CH0971 CH1271 CH1872 CH2472 CH2672R CH3072R for KH3672R, TH3672R, XH3672R, UH3672R CH3672R CH4272R MODEL (System) 26KHH72R 26THH72R 36THH72R HEAT PUMP WITH HEATER 2 Wall Mounted Suspended Outdoor KHH2672R THH2672R THH3672R CH2672R CH3672R Single split over 26000Btu (except 24KS62R) that operates in the A/C mode down to 0 F ambient temperature.

CONTENTS SANYO LineUp p2 3 Model Identification System Capacity in BTU/h Indoor Unit Type K: Wall Mounted T: Suspended X: 4way Recessed U: Conceiled Duct M: MulitiZone 18 K H S 7 2 Voltage: 1:115V 2: 208/230V Component Indoor Unit Type K: Wall Mounted T: Suspended X: 4way Recessed U: Conceiled Duct C: Outdoor unit Model Series No. Wireless remote Control Function H: Heat Pump M: MulitiZone L: Low Ambient K H S18 7 2 Voltage: 1: 115V 2: 208/230V Model Series No. Capacity in BTU/h S: Wireless remote Control H: Heater Function H: Heat Pump KHS1872 Indoor unit 18KHS72 Master model No. (System) + CH1872 Outdoor unit NOTE: All 7 series are R410A models Flexi Multi Inverter Btu/h 7,000 9,000 12,000 18,000 24,000 Type Standard Low Ambient Standard Low Ambient Standard Low Ambient Standard Low Ambient Standard Low Ambient Feature Chart p4 5 Features Features p5 7 Wall A/C 09KS71/09KLS71 12KS71/12KLS71/ 18KS72/18KLS72 24KS72/24KLS72 24KS62R/24KLS62R 26KS72R 30KS72R 36KS72R/36KLS72 p8 9 AIR CONDITIONER HEAT PUMP Wall Mounted KMS0772 KMS0972 KMS1272 KMS1872 KMS2472 Btu/h 19,000 24,000 31,000 Type Standard Low Ambient Standard Low Ambient Standard Low Ambient Outdoor CM1972 CLM1972 CM2472 CLM2472 CM3172 CLM3172 Btu/h 7,000 9,000 12,000 18,000 24,000 Wall Mounted Up to 3 Up to 4 Up to4 KMHS0772 KMHS0972 KMHS1272 KMHS1872 KMHS2472 Btu/h 19,000 24,000 31,000 Wall H/P 09KHS71 12KHS71 18KHS72 24KHS72 26KHH72R/ 26KH72R 30KH72R 36KH72R p10 11 Flexi Multi 19000 Btu 24000 Btu 31000 Btu p12 ~ 15 Suspended 26TS72R 26TH72R 36TS72R 42TS72R 36TH72R 42TH72R 26THH72R 36THH72R p16 17 Recessed 26XS72R 36XS72R 42XS72R 26XH72R 36XH72R 42XH72R Outdoor Up to 3 Up to 4 Up to4 CMH1972 CMH2472 CMH3172 p18 19 Concealed Duct UH2672R UH3672R p20 21 HEAT PUMP W/ HEATER COOL W/ HEATER V Heater 7000 9000 12000 15000 2.55kW STW0622C2P STW0922C2P STW1222C2P 3.45kW STW0623C2P STW0923C2P STW1223C2P STW1523C2P 5.00kW STW0925C2P STW1225C2P STW1525C2P 3.00kW STW0633C2 STW0933C2 STW1233C2 4.00kW STW0634C2 STW0934C2 STW1234C2 STW1534C2 5.00kW STW0935C2 STW1235C2 STW1535C2 2.55kW STW0622H2P STW0922H2P STW1222H2P 3.45kW STW0623H2P STW0923H2P STW1223H2P STW1523H2P 5.00kW STW0925H2P STW1225H2P STW1525H2P 3.00kW STW0633H2 STW0933H2 STW1233H2 4.00kW STW0634H2 STW0934H2 STW1234H2 STW1534H2 5.00kW STW0935H2 STW1235H2 STW1535H2 230/208V 265V 230/208V 265V STW2 Series STB1 Series V 8000 10000 12000 COOLING ONLY 115V STB0810C1P STB1010C1P 230/208 STB1020C1P STB1220C1P COOLING W/HEATER 115V STB0811C1P 230/208 STB1023C1P STB1123C1P HEAT PUMP W/HEATER 230/208 STB0823H1P Packaged Terminal STW2 Series p22 26" Thru The Wall STB1 Series p23 Portable P0811 p24 Eco Multi CHY7243 p24 Accessory p24 25 Tube Length & Size, Operating Range p26 27 3

MODEL FEATURE CHART : Option Wall Mounted AIR CONDITIONERS 09KS71 12KS71 18KS72 24KS72 24KS62R 09KLS71 12KLS71 18KLS72 24KLS72 LOWAMBIENT AIR CONDITIONERS 24KLS62R 26K72R 30K72R 36K72R HEAT PUMPS W/O HEATER 09KHS71 26KH72R 12KHS71 30KH72R 18KHS72 36KH72R 24KHS72 HEAT PUMPS W/ HEATER 26KHH72R Suspended 26T72R 36T72R 42T72R 26TH72R 36TH72R 42TH42R 26THH72R 36THH72R Recessed 26X72R 36X72R 42X72R 26XH72R 36XH72R 42XH72R Concealed Duct 26U72R 36U72R 26UH72R 36UH72R Apatite Filter Negative Ion Generator Microprocessor Controlled Operation Wireless Remote Control Wired Remote Control SelfDiagnosing Function Dry Mode 3 Fan Speeds and Automatic Fan Operation Air Sweep Control Louver Control Automatic and Changeover Night Setback Mode for and Hot Start System 24Hour Clock with ON/OFF Program Timer 72Hour ON/OFF Timer 1Hour OFF Timer Weekly Timer System Controller AntiMold Filter Filter Sign Automatic Restart Function after Power Failure Fresh Air Intake Duct Extension BuiltIn Drain Pump Low Ambient Operation Electric Expansion Valve ODP=0 Refrigerant 4

Features SANYO: Your Best Choice in Ductless Split Air Conditioning Systems Sanyo s Ductless Split Air Conditioner & Heat Pump products offer wide versatility in solving your cooling and heating requirements. The Indoor unit (evaporator) is mounted inside the room, enclosed in a handsome space saving cabinet. It is connected to the outdoor unit (condenser) via refrigerant lines & interunit wiring through a 31/2" opening in the wall. Since no ductwork is required, installation is simple, fast & efficient. There is no need to use up window space or cut large openings in existing walls, which could undermine the integrity of your structure, and even pose security risks. Since the Rotary compressor is located in the outdoor unit, compressor operating noise is virtually eliminated from the indoor. The indoor unit has been uniquely designed to provide Whisper Quiet operation while delivering comfort throughout the room (s). In addition, rotary compressors provide efficient, powerful cooling at the lowest noise levels in the industry. DC INVERTER is outstanding for it s RAPID COOLING & HEATING POWER. As soon as the temperature is reached, it automatically adjusts current frequency temperature fluctuation. It also provides ENERGYSAVING (which saves your electricity charges) as well as QUIETER ERATION. High Power Mode The unit operates at maximum capacity by pressing a High Power Mode button. Compressor Driving Hz Maximum Hz High Power Rapid and Since the DC Inverter Air Conditioner has efficient rapid heating and cooling capacity produced by variable compressor rotation speed, it ensures quicker control of room temperatures than conventional air conditioners. 30 minutes Time Room Temp. Mode DC Inverter air conditioner Conventional air conditioner EnergySaving Operation The DC Inverter Air Conditioner affords continuous operation, while it adjusts capacity according to the room temperature. The accurate sensing of cooling or heating loads prevents frequent changes in capacity and ensures efficient, economical operation. Quiet Operation The DC Inverter Air Conditioner uses a twin rotary compressor. Compared to the conventional single cylinder type, the twin rotary compressor dramatically reduces vibration and noise during operation, thus ensuring quiet operation. High SEER With the integration of inverter technology and R410A refrigerant, our products meet the DOE of a minimum requirement of SEER. Desired temperature 0 C Desired temperature Room Temp. 0 C Time until desired temperature is reached Mode DC Inverter air conditioner Conventional air conditioner Time until desired temperature is reached Time Time ODP (Ozone Depletion Potential) = 0 of HFC refrigerant is used. All Sanyo units are conduit connectable for more safety. 5

Features MicroprocessorControlled Operation Microprocessor control ensures that the temperature and humidity levels in the room are always comfortable. Wireless Remote Control Sanyo s infrared Remote Control with and easy to read LCD Display, gives the user the capability to adjust & set: temperature, sweep (louver control), fan speeds, timer, night setback and more, for complete automatic operation. Dry Mode By coupling compressor and fan operation, intermittent operation can be precisely controlled according to room temperature, so that air is efficiently dehumidified. 3 Fan Speeds and Automatic Fan Operation Convenient microprocessor control automatically adjusts fan speed to High, Medium or Low. According to room temperature to maintain a comfortable airflow throughout the room. Air Sweep Control The air sweep function moves the louver up and down in the air outlet, directing air in a sweeping motion around the room and providing comfort in every corner. Cool/Dry Mode Heat Mode Flap Louver Control Louver can be manually set to the desired angle by remote control. Negative Ions Generator The abundance of negative ions is found near waterfalls and forests. The negative ions generator fills your room with negative ions throughout the year. *Ion generating power over 100,000 parts/cc Automatic and Changeover After setting the temperature and functions you desire, just relax. If the room temperature is higher than the set temperature, cooling operation begins. If the room temperature is lower than the set temperature, heating operation begins. During normal thermostat cycle operation, cooling and heating operations automatically change in accordance with set temperature, time and room temperature. (Heat Pump unit only) 1hour OFF Timer When this button is pushed either while the unit is operating or while it is stopped, the unit will operate for one hour and then switch off automatically. 12hour ON/OFF Timer This timer can be set to automatically turn the unit on or off at any time within a 12hour period. 24hour Clock with ON/OFF Program Timer The remote control unit allows you to set a wide variety of timerbased operations. Such functions include automatic ON/OFF with a timer setting, same time ON/OFF every day, ON timer, OFF timer and Combination timer. ON/OFF Timer Remote controller ON/OFF timer can be set to 0.5 hour gradations (max. 72 hours). Setting temperature Setting temperature In and DRY Mode 2 F 30 min. 30 min. Press the NIGHT SETBACK button Time In Mode Press the 30 min. 30 min. NIGHT SETBACK button Time Night Setback Mode for and and DRY Mode: With the Night Setback Mode, the air conditioner automatically raises the setting temperature 2 F after 30 minutes, and then another 2 F after the next 30 minutes. Mode: With the Night Setback Mode, the setting temperature is automatically lowered 4 F after 30 minutes, and then another 4 F after the next 30 minutes. This saves energy without sacrificing comfort and is ideal for gentle cooling and heating. Automatic Restart Function after Power Failure This feature allows the system to automatically resume operation at its preset program, after power is restored from a power failure. Hot Start System Right from the start, air is warm and comfortable. The Hot Start System prevents any cold blasts at the beginning while the heat pump is warming up. (Heat pump unit only) Air Clean Apatite Filter Apatite or calcium phosphate is highly effective in trapping germs, mites and mite excrement, pollen, dirt and dust, and cigarette odor. The triple layered air clean apatite filter consists of antibacterial, deodorizing, and dustcollecting sections that maintain healthy, clean air in your room. 4 F 2 F 4 F AntiMold Filter Filter is treated with antimold chemicals to prevent mold or bacteria from occurring. BuiltIn Drain Pump Max. head 30 inches from the bottom of the unit. (condensate pump is only for allowing drain line to meet minimum gravity flow requirements.) Electric Refrigerant Control Valve The circulation volume of the refrigerant is controlled by a pulse type electric control valve. In order to attain optimum efficiency, when the power is switched ON, the opening degree of the electric control valve is controlled between 90 and 480 steps. ( Recessed Models only.) Additional Features Filter Sign Filter sign informs you when filter maintenance is necessary. 2,500 hrs: X, Ttypes 150 hrs: Ktype (RCSTM80BG) SelfDiagnosing Function Details of previous warnings are stored and can be verified on the liquid crystal display. This makes it easier to diagnose malfunctions, greatly reducing service labor. (Wired remote controller) (RCSTM80BG) 6

Additional Features Wired Remote Controllers (Optional) over 26000 Btu, Except 24KS62R / 24KLS62R Timer Remote Controller (RCSTM80BG) System Controller (SHAKC64UG) Basic remote controller ON/OFF Operation mode changeover (,, Dry, Auto, Fan.) Temperature setting (/Dry: 64 F86 F : 61 F86 F.) Air volume adjustment (HH, H, LL, Auto.) Air flow direction adjustment. Time Function 24 hours real time clock. Day of the week indicator. Weekly Program Function A maximum of 6 actions can be programmed for each day. Unoccupied Function Allows the temperature of the conditioned space to be preset to a desired temperature, which will be maintained until manually changed. This feature is initiated by pressing the symbol then setting the temperature by using the up or down arrows on the control. This provides a method of maintaining room temperature while at work or away on vacation, etc. Sleeping Function This function controls the room temperature for comfortable sleeping. Max. 8 indoor units can be controlled from one remote controller. Remote control by main remote controller and sub controller is possible. Max. 2 remote controller (main remote controller and sub controller) can be installed for one indoor unit. Used in combination with remote controllers, the system controller can control up to 64 groups of indoor units (max. 64 indoor units). Separating the 64 indoor units into 4 zones, each zone can be controlled individually. Up to 16 groups (indoor units) can be registered to each zone. Collective control and individual group (unit) control can also be performed. System without remote controller is also available. Up to 2 system controllers (1 main, 1 sub) can be installed in a system. Alarm and operation outputs for an external collected signal are available (potential free contact). Wireless Remote Controllers (Optional) over 26000 Btu, Except 24KS62R / 24KLS62R Applicable Unit Wireless Remote Controller Kseries Xseries ( Recessed Type) BUILTIN TYPE Signal receiving unit can be installed in the outer panel of indoor unit. Control panel can be installed in the inside indoor unit. For All Indoor Units Tseries ( Suspended Type) Useries Xseries Tseries EXTERNAL TYPE Separate type signal receiving unit. RCSSH1UA RCSSH80UA.WL RCSBH80UA.WL Remote Controllers Functions Function System Setting Range ON/OFF Operation mode switch Dry Fan Temp setting Fan speed setting (Hi/Mid./Lo/Auto) Auto airflow direction setting Auto flap Arbitrary airflow direction setting Sweep (Flap swing) Sensor temp. display Selfdiagnostic function Central control (at hand inhibited) Group control Concurrent use with weekly timer, dry ( F) ( F) Timer Remote Controller System Controller (RCSTM80BG) (SHAKC64UG) (Collective/Individual) (Individual) (Individual) (Individual) (Individual) (Individual) (Individual) * * (Up to 8 units) (Up to 16 groups) 65 86 61 79 : Controllable : Uncontrollable NOTE: If you use both remote controller and system controller concurrently, both controllers can be used on a lastsignal priority basis. 7

INVERTER MultiSystem FlexiMulti Fits with Various Sizes of Room and Life Style The multisystem type allows a single outdoor unit to be connected to 2 to 4 indoor units. It also solves the problem of limited installation space and does not clutter the exterior of your home. KMS0772 / KMS0972 / KMS1272 KMHS0772 / KMHS0972 / KMHS1272 KMS1872 / KMS2472 KMHS1872 / KMHS2472 Indoor Unit: Wall Mounted Type Model No. Power Source Capacity Btu/h Unit Dimensions (HxWxD) inch Net Weight Lbs Air Circulation (H/L) m 3 /h m 3 /h Operating Sound (H/L) dba dba Refrigerant Narrow Tube inch Tube Diameter Wide Tube inch KMS0772 7,500 19.8 33 / 23 3/8" Only KMS0972 KMS1272 230V60Hz KMS1872 KMS2472 9,000 11,900 17,500 24,200 11"7/32" x 32"15/32" x 7"7/16" 11"23/32" x 41"15/16" x 8"19/32" 19.8 34 / 23 19.8 36 / 25 26.5 41 / 28 26.5 44 / 30 3/8" 3/8" 1/2" Only for CLM1972, CLM2472, CLM3172 5/8" Model No. Power Source Capacity Btu/h Btu/h Unit Dimensions (HxWxD) inch Net Weight Lbs Air Circulation (H/L) m 3 /h Operating Sound (H/L) dba dba Refrigerant Narrow Tube inch Tube Diameter Wide Tube inch KMHS0772 7,500 8,500 19.8 33 / 23 33 / 23 3/8" Heat Pump KMHS0972 KMHS1272 230V60Hz KMHS1872 KMHS2472 9,000 12,200 11,900 14,300 17,500 20,400 24,200 29,000 11"7/32" x 32"15/32" x 7"7/16" 11"23/32" x 41"15/16" x 8"19/32" 19.8 34 / 23 34 / 23 3/8" 19.8 36 / 25 34 / 25 3/8" 26.5 41 / 28 40 / 28 1/2" 26.5 44 / 30 43 / 30 5/8" 12

DC Inverter MultiSystem Outdoor Unit Connectable from 2 to 3 Indoor Units Up to 3 CM1972 / CLM1972 CMH1972 Model No. Oudoor Unit CM1972 / CLM1972 CMH1972 Performance Capacity Btu/h Air Flow High CFM Number of Connectable Indoor Units SEER HSPF Electrical Rating Power Supply V, Phase, Hz Running Ampere A Power Input W Features Controls Fan Speeds Compressor Refrigerant / Amount Charged at Shipment g Refrigerant Control Operation Sound Hi dba Refrigerant Tubing Connections Max. Allowable Tubing Length per Unit Ft Refrigerant Narrow Tube inch Tube Diameter Wide Tube inch Dimensions & Weight Unit Dimensions H x W x D inch Net Weight Lbs IMPORTANT It is not possible to connect an outdoor unit to only a single indoor unit. If operated with only ONE indoor unit installed, the returning refrigerant to the compressor may cause a malfunction. 19,700 1,700 2 ~ 3 230V / 208V, 1Ph, 60Hz 6.52 / 7.19 1,465 / 1,465 Microprocessor Auto (Hi, Me, Lo) DC Inverter R410A / Electric Expansion Valve 50 Flare Type 150 x 3" 3/8" x 2" / 1/2" x 1" 29"1/8" x 35"1/2" x 12"5/8" 8 19,100 24,800 1,700 2 ~ 3 7.7 230V / 208V, 1Ph, 60Hz 6.20 / 6.86 7.25 / 8.00.95 /.95 16.30 / 16.30 Microprocessor Auto (Hi, Me, Lo) DC Inverter R410A / Electric Expansion Valve 50 52 Flare Type 150 x 3" 3/8" x 2" / 1/2" x 1" 29"1/8" x 35"1/2" x 12"5/8" 143

DC Inverter MultiSystem Outdoor Unit Connectable from 2 to 4 Indoor Units Up to 4 CM2472 / CLM2472 CMH2472 Model No. Oudoor Unit CM2472 / CLM2472 CMH2472 Performance Capacity Btu/h Air Flow High CFM Number of Connectable Indoor Units SEER HSPF Electrical Rating Power Supply V, Phase, Hz Running Ampere A Power Input W Features Controls Fan Speeds Compressor Refrigerant/Amount Charged at Shipment g Refrigerant Control Operation Sound Hi dba Refrigerant Tubing Connections Max. Allowable Tubing Length per Unit Ft Refrigerant Narrow Tube inch Tube Diameter Wide Tube inch Dimensions & Weight Unit Dimensions H x W x D inch Net Weight Lbs IMPORTANT 25,400 1,700 2 ~ 4 230V / 208V, 1Ph, 60Hz 10.91 / 12.05 2,455 / 2,455 Microprocessor Auto (Hi, Me, Lo) DC Inverter R410A/ Electric Expansion Valve 50 Flare Type 200 x 4" 3/8" x 2" / 1/2" x 1" / 5/8" x 1" 29"1/8" x 35"1/2" x 12"5/8" 23,200 29,200 1,700 2 ~ 4 7.7 230V / 208V, 1Ph, 60Hz 8.60 / 9.50 9.62 / 10.63 1,935 / 1,935 2,165 / 2,165 Microprocessor Auto (Hi, Me, Lo) DC Inverter R410A / Electric Expansion Valve 50 52 Flare Type 200 x 3" 3/8" x 2" / 1/2" x 1" / 5/8" x 1" 29"1/8" x 35"1/2" x 12"5/8" It is not possible to connect an outdoor unit to only a single indoor unit. If operated with only ONE indoor unit installed, the returning refrigerant to the compressor may cause a malfunction. 14

Connectable from 2 to 4 Indoor Units Up to 4 CM3172 / CLM3172 CMH3172 Model No. Oudoor Unit CM3172 / CLM3172 CMH3172 Performance Capacity Btu/h Air Circulation (High) High m 3 /h Number of Connectable Indoor Units SEER HSPF Electrical Rating Power Supply V, Phase, Hz Running Ampere A Power Input W Features Controls Fan Speeds Compressor Refrigerant/Amount Charged at Shipment g Refrigerant Control Operation Sound Hi dba Refrigerant Tubing Connections Max. Allowable Tubing Length per Unit Ft Refrigerant Narrow Tube inch Tube Diameter Wide Tube inch Dimensions & Weight Unit Dimensions H x W x D inch Net Weight Lbs 30,600 1,940 2 ~ 4 230V / 208V, 1Ph, 60Hz 11.70 / 12.90 2,660 / 2,660 Microprocessor Auto (Hi, Me, Lo) DC Inverter R410A / Electric Expansion Valve 53 Flare Type 230 x 4" 3/8" x 2" / 1/2" x 1" / 5/8" x 1" 35"1/32" x 35"1/2" x 12"5/8" 30,600 32,000 2 ~ 4 7.7 230V / 208V, 1Ph, 60Hz 11.70 / 12.90 9.70 / 10.70 2,660 / 2,660 2,210 / 2,210 Microprocessor Auto (Hi, Me, Lo) DC Inverter R410A / Electric Expansion Valve 53 52 Flare Type 230 x 3" 3/8" x 2" / 1/2" x 1" / 5/8" x 1" 35"1/32" x 35"1/2" x 12"5/8" IMPORTANT It is not possible to connect an outdoor unit to only a single indoor unit. If operated with only ONE indoor unit installed, the returning refrigerant to the compressor may cause a malfunction. 15

Because its products are subject to continuous improvements, Sanyo reserves the right to modify product design and specifications without notice and without incurring any obligations. Copyright 2006, SANYO Air Conditioning Products. SANYO Fisher Company A Division of SANYO North America Corporation 21605 Plummer Street, Chatsworth, CA 911, USA Phone: 8189987322 Fax: 8187014170 website: http://www.sanyohvac.com