MicW i436 on iphone 6 / iphone 6 Plus basedreal Time



Similar documents
SMARTPHONE AS NOISE LEVEL METER? Jacopo Fogola, Stefano Masera, Vincenzo Bevacqua Environmental Protection Agency - Piedmont Region, Turin, Italy

Evaluation of Smartphone Sound Measurement Apps

Outer Diameter 23 φ mm Face side Dimension 20.1 φ mm. Baffle Opening. Normal 0.5 Watts Maximum 1.0 Watts Sine Wave.

MICROPHONE SPECIFICATIONS EXPLAINED

10EaZy SW White Paper Choosing the right hardware

Condenser Microphone Cartridges Types 4133 to you to build up the measurement systems of your choice without compromising quality or standards.

The completely Ethernet-based. protocol enables several imode devices to be linked, using easily-sourced. cables and components.

E R0 ACOUSTICAL PERFORMANCE TEST REPORT ASTM E90. Rendered to: TREX COMPANY, LLC. Series/Model: Trex Seclusion

Cheap acoustics as a learning methodology

Step-by-Step RECD Guide

Airborne Sound Insulation

Testing Panasonic s WM-61A Mike Cartridge

AM-1. AM-1 Setup Guide for the Polycom Video Conferencing Systems QUICK SETUP GUIDE

Sound Pressure Measurement

Quick Guide for Using Beltone MFi Hearing Aids with your iphone

M3 Instruction Manual

AN-007 APPLICATION NOTE MEASURING MAXIMUM SUBWOOFER OUTPUT ACCORDING ANSI/CEA-2010 STANDARD INTRODUCTION CEA-2010 (ANSI) TEST PROCEDURE

PRODUCT CATALOG BSWA

High Pressure Measurements with the High Pressure Microphone Calibrator Type Introduction. The High Pressure Microphone Calibrator Type 4221

CLIO 8 CLIO 8 CLIO 8 CLIO 8

Relationship between Sound Pressure and Sound Power Levels

SOUND LEVEL METER 94405

PRODUCT SHEET OUT1 SPECIFICATIONS

HyperX Cloud Headset

Stunning sound and revolutionary intelligence to analyze and correct the problems in any room.

CASE STUDY. History. National Renewable Energy Laboratory Testing Wind Turbine Power Generators using PULSE. United States of America

Generic - Hearing Loop - (AFILS) U.S. System Specification

Acoustic Measurement Sensors & Instrumentation

Sound Power Measurement

SC-30 INTEGRATING SOUND LEVEL METER REAL TIME FREQUENCY ANALYZER

Data sheet LX-11. Linea-Series Directional Speakers.


Acoustical Surfaces, Inc.

SOUND MEASURING INSTRUMENTS

Absorption mufflers in exhaust systems. Rolf Jebasinski. J. Eberspächer GmbH & Co. Abstract

Outperform. Bryston is pleased to announce the HT Series Loudspeaker System

Engineering Research Report

PCB Radiation Mechanisms: Using Component-Level Measurements to

SPEECH INTELLIGIBILITY and Fire Alarm Voice Communication Systems

Desktop and Integrated Desktop Computer Product Environmental Information Declaration Form for COMMISSION REGULATION (EC) No 617/2013

APPLICATION NOTE. Ear Simulator for Telephonometry. Use of Wideband Ear Simulator Type 4195

Development and optimization of a hybrid passive/active liner for flow duct applications

Tutorial

RECOMMENDATION ITU-R BR *, ** Parameters for international exchange of multi-channel sound recordings with or without accompanying picture ***

Tuning Subwoofers - Calibrating Subwoofers

Testing FM Systems on the FP35 Hearing Aid Analyzer -1-

User's Guide. Integrating Sound Level Datalogger. Model Introduction

INTER-NOISE DECEMBER 2006 HONOLULU, HAWAII, USA

Application note for Peerless XLS 10" subwoofer drive units

USER GUIDE PREFIX PREMIUM BLEND

Data Sheet, V1.1, May 2008 SMM310. Silicon MEMS Microphone. Small Signal Discretes

Noise. CIH Review PDC March 2012

Castle Mirus Sound Meter

A Microphone Array for Hearing Aids

ASTM E 90 SOUND TRANSMISSION LOSS TEST REPORT. Rendered to: MGM INDUSTRIES SERIES/MODEL: TYPE: Single Hung Window

Sound Level Meters Nor131 & Nor132

Application Note. Introduction to. Page 1 / 10

GUIDELINES ON THE ACOUSTICS OF SOUND FIELD AUDIOMETRY IN CLINICAL AUDIOLOGICAL APPLICATIONS

D A. TASCAM PCM Recorder. iphone/ipad/ipod touch Application USER'S GUIDE

BASIC SOUND LEVEL METERS

TI 313 (1.0 EN) d&b Remote network - Integration

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

Press Release Sony s New Portable Headphone Amplifier PHA-1 Delivers Powerful Sound Quality Hong Kong, December 6, 2012

Congratulations! Thank you!

VAT CALCULATED AT 23% (AS FROM 1/1/12)

ASTM E 90 SOUND TRANSMISSION LOSS TEST REPORT. Rendered to: TUBELITE, INC. SERIES/MODEL: T TYPE: Two-Lite Storefront

Product specifications

LMS Test.Xpress Powering personal productivity

Manual Analysis Software AFD 1201

How To Reduce Noise From A Test Screen

Voice Communication Package v7.0 of front-end voice processing software technologies General description and technical specification

Portable DIY Headphone Amplifiers. By: Alex Gurga

NOISE EVALUATION IN A RACE-TRACK: MEASUREMENTS, SOFTWARE ANALYSES AND NEED OF CONTINUOUS MONITORING. COMPARISON AMONG THE RESULTS.

Linear Parameter Measurement (LPM)

Phonak Naída Q. Product information

INTERNATIONAL ANNEX III. Technical Details of Sound Signal Appliances

Data sheet LX-10. Linea-Series Directional Speakers.

ACOUSTIC PERFORMANCES OF AN HEMIANECHOIC ROOM FOR ELECTROMAGNETIC COMPATIBILITY TESTS

The world s first Acoustic Power Equalization Technology Perfect Acoustic Power Equalization. Perfect Time/Phase Alignment.

Rated Power(W) 8W 2. EG-LED W 3. EG-LED W

RoomMatch Utility RMU105 TECHNICAL DATA SHEET. ultra-compact foreground/fill loudspeaker. Key Features. Technical Specifications

Tuning a Monopole Antenna Using a Network Analyzer

The Effects of Ultrasonic Sound Generated by Ultrasonic Cleaning Systems on Human Hearing and Physiology

SiSonic Design Guide

Instructions for the use of E-A-RTONE 3A. Insert Earphones. Revised 1997 per ANSI S and ISO 389-2: /99

Integrating Sound Level Meter and Datalogger

FAQ OLYMPUS DICTATION SMARTPHONE APPLICATION

Evaluating Real-World Hearing Aid Performance in a Laboratory

Blue Sky International 70 Sea Lane Farmingdale, NY MediaDesk 2.1 Monitoring System. Owner s Manual

Quick Guide. Using ReSound Smart hearing aids with your iphone, ipad and ipod touch

USER GUIDE ELLIPSE AURA RETAIL

How To Design A Microphone For A Cell Phone Or Other Device

APP CLOCK INTRODUCTION

Testing laboratory HVAC. Test report No.: HP e

User's Guide Integrating Sound Level Datalogger Model

Transcription:

Technical Note 1501 MicW i436 on iphone 6 / iphone 6 Plus basedreal Time Analyzers (RTA) 1. Introduction With new iphone 6 and iphone 6 Plus being released in October 2014, the iphone based real time analyzer is becoming industrial standard measurement devices. MicW i436 microphone for iphonesthus becomes popular in the sound measurement community due to itsspecialty and compatibility. In thistechnical Notes, we will evaluate the performance of i436 on iphone 6 and iphone 6 Plus from following aspects: 1) Measurement Range 2) Calibration 3) Frequency Responses 4) Frequency Response Data Compensation 5) Applications and comparisons Fig. 1 iphone RTA system consists of iphone 6 (or 6+), i436 and APP software 2. Hardwareand Software The following hardwares and softwareswere used in the measurement: 1) MicW i436 microphones 2) iphone 6 (model A1549) 3) iphone 6 Plus (model A1524) 4) SigScopePro 4.4 (r1044) 3. Measurement Range The measurement range is the range of sound pressure levels that the iphonerta system can measure. 1 / 8

3.1 The minimum sound pressure level of the iphone 6 RTA system The iphone6 RTA system s minimum SPL was measured in BSWA anechoic chamber. The background noise level of the chamber is 16 dba. The measurements were taken at three Gain settings in the software Fig.2 Gain settings in the software Fig. 3 Measurements in anechoic chamber 3.2 The maximum sound pressure levels The maximum SPL of the iphone system was measuredby using BSWA high pressure calibrator CA905 which can generate 170 db sound sources in a small cavity. 2 / 8

Fig. 4 Setup for Maximum SPL testing. Thesignal starts to distort when the SPL reaches 130 db. 3.3 The results of measurement ranges at different Gain Settings The results are shown in Table 1. Software Gain Setting Minimum SPL (dba) Maximum SPL (db) Low 43 128 Middle 33 110 High 30 90 Table 1 Measurement Ranges for Phone 6 based RTA with i436 4. Frequency Responses of iphone 6 based RTA with i436 The frequency responseswere tested in the BSWA anechoic chamber. The testing methodfollows standard IEC 61094-8. The final result is the average of 5 trials of tests using i436. The differences between iphone 6 and iphone 6 plus are smaller than 0.2dB. 3 / 8

Fig. 5 Measurement setup for testing the frequency response Frequency Response of iphone 6 and ipone 6 Plus with i436 microphone (Averaged Results) Sound Pressure Level (db) 5.00 0.00-5.00-10.00-15.00-20.00-25.00-30.00 20.00 200.00 Frequency(Hz) 2000.00 20000.00 Fig. 6 Frequency Responses for iphone 6 and iphone 6 + with i436 4 / 8

Upload the frequency response data to SigScopePro APP, and the APP has the function to compensate the measurement data. Fig. 5 Compensate Frequency Response Data to the APP Frequency (Hz) Corrections (db) 20-5.77 25-4.07 31.5-2.57 40-1.30 50-0.47 63-0.17 80-0.03 100 0.00 125 0.00 160 0.00 200 0.00 250 0.00 315 0.00 400 0.00 500 0.00 630 0.00 800 0.00 1000 0.00 1250 0.00 1600 0.00 2000 0.00 2500 0.00 3150 0.00 4000 0.00 5000 0.80 6300 1.15 8000 1.01 10000-0.78 12500-1.29 16000-3.51 20000-7.91 Table 2 Frequency Response data for iphone 6 and iphone 6 + with i436 5. Calibration 5 / 8

To calibrate MicW i436, the app requires the sensitivity of i436microphonethat is already given in User s Manual. The unit of the sensitivity is mv/pa. The iphone 6 and iphone 6 Plus have internal amplification circuits, the amplification factor of iphones was measured by using BSWA CA114 Sound Level Calibrator (94.0 db at 1000 Hz) and resultis1.28. Fig 7. Sensitivity of the each i436 in User s Manual Steps to calibrate the iphone 6 based RTA: (1) Read the sensitivity value in User s Manual. Forexample, the sensitivity is 7.4 mv/pa in Fig. 7,. (2) Calculate the input sensitivity by multiplyingthe amplification factor 1.28 and sensitivity. Forexample, The Input Sensitivity = 7.4 x 1.28 = 9.47 mv/pa (3) Input 0.00947 (V/Pa) into APP as shown in Fig.8. (4) Press < on the upper right. Fig. 8 Input Sensitivity inapp 6 / 8

6. Applications [6] An independent study was conducted in University of Kentucky to compareipadmini based RTAwith i436andlms SCADAS system. The results are shown in Fig9 and Fig10. 70 Sound Pressure Level (db) 60 50 40 30 20 10 0-10 -20 MicW + ipad mini PCB + SCADAS -30 50 500 5000 Frequency (Hz) Fig. 9 Comparison of ipad mini using i436 with LMS SCADAS using PCB microphone for white noise in the anechoic chamber. Sound Pressure Level (db) 100 90 80 70 60 50 40 30 20 10 0 MicW + ipad mini PCB + SCADAS 0 5000 10000 Frequency (Hz) 15000 20000 Fig. 10 Comparison of ipad mini using i436 with LMS SCADAS using PCB microphone at 0.5 m from the exhaust of Hardy- Davis motorbike. References 7 / 8

[1] IEC 61094-1: 1991, Measurement microphones - Part 1: Specifications for laboratory standard microphones [2] IEC 61094-4: 1995, Measurement microphones - Part 4: Specifications for working standard microphones [3] IEC 61094-6: 2004, Measurement microphones - Part 6: Electrostatic actuators for determination of frequency response [4] IEC 61672-1 2002, Electroacoustics- Sound Level Meters [5] IEC 61094-1: 1991, Measurement microphones - Part 8:Methods for determining the free- field sensitivity of working standard microphones by comparison. [6] Gong Cheng and Ruimeng Wu, 2014, Data Acquisition for the ipad. Vibro- Acoustics Consortium Meeting, the University of Kentucky. 8 / 8