SDT 2960 Simultaneous DSC-TGA including DTA capabilities



Similar documents
Weight Loss Determined from Mass Spectrometry Trend Data in a Thermogravimetric/Mass Spectrometer System

DSC Differential Scanning Calorimeter

Characterization of Electronic Materials Using Thermal Analysis

TA INSTRUMENTS DIFFERENTIAL SCANNING CALORIMETER (DSC) Insert Nickname Here. Operating Instructions

Differential Scanning Calorimetry DSC

Characterization of Polymers Using TGA

STANDARD CLEANING AND CALIBRATION PROCEDURE FOR TGA-50(H) AND TGA-51(H)

Table of content. L81/RITA high speed Thermo Balance. Quattro Dilatometer. L75/1250/B/S Macro Dilatometer. New air cooled furnace program

TGA/SDTA851 e Module. Thermal Analysis. Technical data Quality Service

Bridging the analytical gap

XFA 600 Thermal Diffusivity Thermal Conductivity

Thermal Analysis. Application Handbook. Thermal Analysis of Polymers Selected Applications

Fundamentals of Mass Flow Control

Better DSC Isothermal Cure Kinetics Studies Using Power Compensation DSC

Lecture 35: Atmosphere in Furnaces

Measurement of Specific Heat Capacity Using Differential Scanning Calorimeter

G8 GALILEO. Innovation with Integrity. High-End Melt-extraction Analyzer. Inert Gas Method

FP628. Nitrogen / Protein Determination by Combustion. Rev 1-6/8/11

CHARACTERIZATION OF POLYMERS BY TMA. W.J. Sichina, National Marketing Manager

Phase Transitions and Differential Scanning Calorimetry

RESULTS OF ICARUS 9 EXPERIMENTS RUN AT IMRA EUROPE

TA Instruments User Training

Pore size and BET surface area. analysis at your fingertips. SA Gas Adsorption Analyzer

DETERMINATION OF THE HEAT STORAGE CAPACITY OF PCM AND PCM-OBJECTS AS A FUNCTION OF TEMPERATURE. E. Günther, S. Hiebler, H. Mehling

Thermochemistry I: Endothermic & Exothermic Reactions

Thermochemistry: Calorimetry and Hess s Law

Determination of the heat storage capacity of PCM and PCM objects as a function of temperature

4 Thermomechanical Analysis (TMA)

Thermal diffusivity and conductivity - an introduction to theory and practice

Part B 2. Allow a total of 15 credits for this part. The student must answer all questions in this part.

Elemental analyzer multi EA 5000

DETERMINING THE ENTHALPY OF FORMATION OF CaCO 3

MILESTONE H E L P I N G C H E M I S T S

Effects of Tg and CTE on Semiconductor Encapsulants

Expansion and shrinkage of fibers

HFM Heat Flow Meter Thermal Conductivity Analyzer

FT-NIR for Online Analysis in Polyol Production

DMA-1 Direct Mercury Analyzer

Chemical Formulas, Equations, and Reactions Test Pre-AP Write all answers on your answer document.

Analytical Testing Services Commercial Price List ManTech International Corporation January 2016

G4 ICARUS HF. Innovation with Integrity. Simultaneous Determination of Carbon and Sulfur in Solids. Combustion Method

Graphite Furnace AA, Page 1 DETERMINATION OF METALS IN FOOD SAMPLES BY GRAPHITE FURNACE ATOMIC ABSORPTION SPECTROSCOPY (VERSION 1.

Thermal Analysis 60 Series Application Data Book Foods and Pharmaceuticals

Measuring Temperature withthermistors a Tutorial David Potter

EXAMPLE EXERCISE 4.1 Change of Physical State

Review - After School Matter Name: Review - After School Matter Tuesday, April 29, 2008

atm = 760 torr = 760 mm Hg = kpa = psi. = atm. = atm. = 107 kpa 760 torr 1 atm 760 mm Hg = 790.

Thermal Analysis Technology

5. Which temperature is equal to +20 K? 1) 253ºC 2) 293ºC 3) 253 C 4) 293 C

Bomb Calorimetry. Example 4. Energy and Enthalpy

DETERMINATION OF TOTAL CARBON, TOTAL ORGANIC CARBON AND INORGANIC CARBON IN SEDIMENTS

IUCLID 5 COMPOSITION AND ANALYSIS GUIDANCE DOCUMENT: IRON ORES, AGGLOMERATES [EINECS NUMBER , CAS NUMBER ] IRON ORE PELLETS

VALIDATION OF ANALYTICAL PROCEDURES: TEXT AND METHODOLOGY Q2(R1)

Lasline, Nitrocut, Oxycut gases for laser cutting, Expertise that gets right to the point

Balancing chemical reaction equations (stoichiometry)

The first law: transformation of energy into heat and work. Chemical reactions can be used to provide heat and for doing work.

API 3200 LC/MS/MS SYSTEM. Performance, productivity and value combined

IB Chemistry. DP Chemistry Review

Thermal cover:layout 1 1/18/11 3:56 PM Page 2 TA Instruments

Calculate Available Heat for Natural Gas Fuel For Industrial Heating Equipment and Boilers

Universal Analysis 2000

Prentice Hall. Chemistry (Wilbraham) 2008, National Student Edition - South Carolina Teacher s Edition. High School. High School

Calculation of Liquefied Natural Gas (LNG) Burning Rates

Typical Aluminum GFM Mass Flow Meter

Advances in Thermal Dispersion Mass Flow Meter Accuracy

Adiabatic Bomb Calorimetry

Effect of Magnesium Oxide Content on Final Slag Fluidity of Blast Furnace

Chrysotile Asbestos in Pure Talc

Amount of Substance.

Chemistry 11 Some Study Materials for the Final Exam

CHEMISTRY STANDARDS BASED RUBRIC ATOMIC STRUCTURE AND BONDING

Determination of the enthalpy of combustion using a bomb calorimeter TEC

The photoionization detector (PID) utilizes ultraviolet

Transfer of heat energy often occurs during chemical reactions. A reaction

Continuous flow direct water heating for potable hot water

BB-18 Black Body High Vacuum System Technical Description

10. CNC Hardware Basics

Chemical reactions allow living things to grow, develop, reproduce, and adapt.

FULL PAPER Standardization of PCM Characterization via DSC

EVERYDAY ENGINEERING EXAMPLES FOR SIMPLE CONCEPTS

EXPERIMENT 12: Empirical Formula of a Compound

1. Thermite reaction 2. Enthalpy of reaction, H 3. Heating/cooling curves and changes in state 4. More thermite thermodynamics

LASER CUTTING OF STAINLESS STEEL

Paper No APPLICATION OF EQCM TO THE STUDY OF CO2 CORROSION

Chapter 2 Chemical and Physical Properties of Sulphur Dioxide and Sulphur Trioxide

In this experiment, we will use three properties to identify a liquid substance: solubility, density and boiling point..

Determination of the enthalpy of combustion using a bomb calorimeter TEC. Safety precautions

A PRIMARY CALIBRATION SYSTEM FOR THE SUPPORT OF HIGH PERFORMANCE GAS FLOW TRANSFER STANDARDS

EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL

T5 Watt-Miser Linear Fluorescent lamps

Thermal processing for drying, heating and cooling

Quality Assurance for the Analysis of Steel by Gas Component Analysis

A n = 2 to n = 1. B n = 3 to n = 1. C n = 4 to n = 2. D n = 5 to n = 2

Chemistry 151 Final Exam

Trace Gas Exchange Measurements with Standard Infrared Analyzers

Influence of Belt Furnace on Glass-to-Metal Seal Process

International Year of Light 2015 Tech-Talks BREGENZ: Mehmet Arik Well-Being in Office Applications Light Measurement & Quality Parameters

Integration Services

Transcription:

SDT 96 including DTA capabilities

: The Technique measures both the heat flows (DSC) and weight changes (TGA) associated with transitions in a material as a function of temperature and time in a controlled atmosphere. Simultaneous measurement of these key material properties not only improves productivity but also simplifies interpretation of results. The complimentary information obtained allows differentiation between endothermic and exothermic events which have no associated weight loss (e.g. melting and crystallization) and those which involve a weight loss (e.g. degradation). The combined evaluation also assures identical experimental and sampling conditions for both measurements, thereby eliminating those sources of uncertainty. covers a wide temperature range from ambient to 15 C making it a powerful tool for studying a wide variety of materials including polymers, ceramics, metals, and other inorganics.

TA Instruments SDT 96 The SDT 96 combines two thermal analysis measurements in a single instrument, thus providing easier interpretation of results and improved productivity at an attractive cost. The SDT 96 s exceptional TGA sensitivity, DSC sensitivity, and stable baseline over a wide temperature range result in unmatched versatility for the selection of materials and the prediction of product performance and in-use lifetime. A unique feature of the TA Instruments SDT 96 is the ability to calculate normalized DSC data based on the actual weight of the sample. DSC data is normalized by dividing the heat flow signal by the sample weight. Most instruments simply use the initial sample weight for this calculation. This practice can yield misleading results since the weight of the sample can (and often does) change during the experiment. The SDT 96 provides the user with the ability to specify how the DSC signals are to be normalized providing more accurate, meaningful, and repeatable results. Further improvements over competitive instruments include mechanical and electronic automation features that will appeal to novices as well as experienced thermal analysts. Convenient and easy sample handling minimizes the possibility of damaging the balance mechanism or thermocouples. The furnace assembly operates via a motor-driven screw for precise alignment and automatic opening and closing. The balance is based on a proven horizontal design which assures excellent sample/atmosphere interaction while minimizing chimney and sample weight effects. In addition, low volume inside the balance and sample areas permits rapid atmosphere changeover. Furthermore, the overall atmospheric flow dynamics make the SDT 96 ideal for coupling to a mass spectrometer or FTIR for evolved gas analysis. TA Instruments proprietary electronics and furnace design assure precise temperature control for stable baselines and optimum DSC performance. Proprietary software corrects for beam growth effects at elevated temperatures even under changing weight conditions. Five-point temperature calibration capability optimizes the accuracy of temperature measurements. Figure Loading Sample Cups on the Balance Arm The SDT 96 is one of many TA Instruments thermal analysis and rheology techniques that complement each other. These modules, along with TA Instruments controllers and software, constitute the most complete, versatile and cost effective systems available for characterizing materials. What Can Tell You DSC-TGA experiments provide important information that can be used to select materials, predict product performance, and improve quality. The technique is particularly useful for determining: Transition temperatures Melting points Composition of multicomponent systems Estimated lifetime of a product Heats of fusion and reactions Decomposition kinetics of materials Oxidative stability of materials Atmosphere effects on materials Reaction kinetics Moisture and volatile content of materials Thermal stability of materials Boiling points Uses of DSC-TGA Research and Development Theoretical research of new materials and processes New materials development Materials selection Formula optimization Applications development End-use performance prediction Competitive product evaluation Quality Control/Assurance Fingerprinting Vendor certification Incoming/outgoing material consistency Process optimization Finished product performance Troubleshooting

Principles of Operation The schematic of the SDT 96 Simultaneous DSC-TGA is shown in Figure 3. The system is based on a dual beam horizontal design that supports both DSC and TGA measurements. A bifilar-wound furnace provides uniform controlled heating up to 15 C. The furnace and furnace tube are a single assembly assuring that the upper temperature limit can be achieved consistently without compromising furnace life. A cooling ring facilitates direct introduction of an air purge into the furnace assembly for rapid automatic cool down between experiments. The entire furnace assembly operates on a motor driven screw to allow automatic opening and closing. the amount of current flowing through the transducer coil. An infrared LED light source and a pair of photo-sensitive diodes detect movement of the arm. A flag at the end of the balance arm controls the amount of light reaching each photo sensor. As weight is lost or gained, the beam becomes unbalanced, causing unequal light to strike the photo-diodes. A restoring current is generated to eliminate this imbalance and return to FURNACE FURNACE TUBE METER MOVEMENT COUNTER BALANCE WEIGHT Figure 3 SDT 96 Schematic PHOTODIODES & SENSORS Purge gas enters the unit through the balance assembly and flows horizontally over the sample and reference. A purge gas flow rate of 1 ml/min is typically used, but it can be increased to 1 ml/min to rapidly purge the balance and sample areas before starting atmosphere sensitive determinations. The backpressure generated PURGE GAS OUTLET by the flowing gas during the experiment prevents the diffusion of gaseous decomposition products into the balance area. DSC measurements are based on a heat flux design. The sample, contained in a pan, and the reference (typically an empty pan) sit on platinum sensors at the end of each balance arm. Differential heat flow to the sample and reference is measured using thermocouples in the balance arms (see Figure 4). Heat flow calibration is based on sapphire heat capacity measurements from to 15 C. Continuous direct measurement of sample temperature accounts for high transition temperature repeatability and accuracy. The TGA weight is measured by a tautband meter movement located at the rear of each balance arm. An optically activated servo loop maintains the balance arm in the horizontal (null) position by regulating REFERENCE CUP SAMPLE CUP PLATINUM SENSOR THERMOCOUPLE the null position. The amount of restoring current is a direct measure of the weight change. The sample balance monitors actual sample weight, while the reference balance is used to correct the TGA measurement for temperature effects like beam growth via a proprietary algorithm. Dynamic Normalization is a unique feature of the TA Instruments SDT 96 which provides the ability to calculate normalized DSC data based on the actual weight of the sample. DSC data is normalized by dividing the heat flow signal by the sample weight. Most instruments simply use the initial sample weight for this calculation. BALANCE ARMS METER MOVEMENT Figure 4 Sample Cup / Sample Thermocouple Configuration SAMPLE CUP SAMPLE HOLDER BALANCE ARM This practice can yield misleading results since the weight of the sample can (and often does) change during the experiment. The SDT 96 takes advantage of its continuous weight measurement providing the user with the ability to specify how the DSC signals are to be normalized providing more accurate, meaningful, and repeatable results.

Features and Benefits The SDT 96 is designed with the operator in mind. It offers levels of performance and convenience which are not present in other commercial DSC-TGA instruments. Many of the SDT 96 s benefits are inherent in its operation as a component of a Thermal Analyst System. Key features and benefits include: Wide Temperature Range, permitting evaluation of transition temperatures and weight changes for polymers and organic chemicals, as well as inorganic materials including ceramics, metals, and glasses. Exceptional Sensitivity, facilitating detection and measurement of very small weight gains or losses (.1µg), and the use of small quantities of material. Dual beam design and proprietary software correct for beam growth effects at elevated temperatures even under changing weight conditions, assuring high accuracy and precision. High DSC sensitivity with Dynamic Normalization, provides the ability to detect weaker transitions, and to normalize heat flow calculations using the actual (instantaneous) sample weight providing more accurate, meaningful and repeatable results. Dynamic Heat Flow Calibration, provides accurate and precise evaluation of heats of reaction over a wide temperature range. Five-Point Temperature Calibration, for maximum temperature accuracy. The operator can choose from one to five calibration standards. High-purity metals with well-documented melting points are typically used. Controlled Atmosphere, with horizontal flow of gas across the sample. This flow pattern helps assure good sample/atmosphere interaction while minimizing chimney and sample weight effects, and is ideal for directing the evolved decomposition gases to an FTIR or mass spectrometer for analysis. Ease of Use Operator-oriented features including: Automated temperature calibration Automated heat flow calibration Automated weight calibration Automated taring and recording of sample weight Automated collection, storage, and display of data Automated furnace opening and closing Automated cool-down between experiments Data Analysis Software Universal Analysis A versatile general purpose data analysis program is an integral part of the Thermal Advantage software. This program analyzes files from all the core modules (DSC, DTA, TGA, SDT, TMA, DEA, and DMA) as well as Micro-Thermal Analysis (µta ) and provides many analysis capabilities including: DSC/TGA Standard Analysis Temperatures of transitions Heats of fusion/reaction Dynamic Normalization loss or gain % at temperature loss at temperature Moisture-free/ash-free calculation Residue analysis Generic Functionality Peak integration Partial areas Onset temperature Step transition Running area integral plots Data point value Tabular data report Results report File export in a variety of formats Curve rotation File addition and subtraction Generic equation calculations X and Y linear transformation Curve overlay Saved analysis Saved session Experimental Flexibility, with the ability to store virtually an unlimited number of methods containing up to 6 segments; each selected from 13 available functions, including control of heating (.1 to 1 C/min), purge gas, and data handling. Both ceramic and platinum sample cups are available in several sizes to facilitate evaluation of a wide variety of samples. Rapid Turnaround, with programmable end-of-run conditions including accelerated furnace cooling using a forced air purge. Compatibility with other thermal/rheology techniques, broadening the range of materials and the types of measurements which can be performed. These other techniques include differential scanning calorimetry (DSC), thermogravimetric analysis (TGA), thermomechanical analysis (TMA), dynamic mechanical analysis (DMA), dielectric analysis (DEA) as well as rheology. These techniques can be run individually, or in multimodule configurations, by the Thermal Analyst controller to provide complete materials characterization.

Heat Flow (W/g) Wt Corrected Heat Flow (W/g) Wt Corrected Heat Flow (W/g) Heat Flow (W/g) 4-4 -4-6 -8 Figure 6 Calcium Oxalate Monohydrate in Air and in Nitrogen -6 4 4 6 8 1-4 -6-8 -1 Figure 7 Sodium Chloride - without Dynamic Normalization Figure 8 Sodium Chloride - with Dynamic Normalization 48.1 J/g 485.7 J/g Air Purge Without Dynamic Normalization Measured Heat of Fusion declines with each subsequent heat Heat #1 393.8J/g Heat # 36.8J/g Heat #3 334.9J/g 797.8 C Calcium Oxalate in Nitrogen Calcium Oxalate in Air Air Purge -1 83 C 7 74 78 8 86-1 7 485.8 J/g -1 83 C -14 65 7 74 78 8 86-4 89.6 C 69.91J/g 111.8 C 35.9 C 9.4J/g 5.% Water (1.891mg) Figure 9 Soda Ash Polymorphic Phase Transitions Melting 473.63 C 15.5 J/g 851.35 C 18.1 J/g 187.18 C -6 9 857.18 C Volatilazation -8 8 4 6 8 1 1 1 8 6 85 8 75 1 11 1 Applications The versatility of the TA Instruments SDT 96 as a valuable tool for materials characterization and quality control is illustrated by these representative applications. These examples also illustrate many of the benefits inherent in the SDT 96 system. Improved Interpretation of Thermal Events results are often used to improve the interpretation of thermal events by providing both DSC and TGA data simultaneously on the same sample. The DSC analysis identifies exothermic/endothermic transitions while the TGA analysis evaluates weight changes which may be associated with those transitions. Calcium Oxalate Monohydrate is a standard material often used to verify TGA performance. Like many materials, it behaves very differently when heated in oxidizing versus inert environments. The addition of DSC data illustrates this effect, and proves very helpful in interpreting data for a wide range of materials. Figure 6 shows Calcium Oxalate Monohydrate data from two SDT experiments, one run in a nitrogen environment, and one run in air. In an inert atmosphere, the sample first loses H O, then CO and finally CO. (TGA- Mass Spec data indicates that some of the CO evolved in step two reacts to form CO, specifically, CO CO + C). All three of these weight losses are endothermic reactions as is evidenced in the DSC data. The TGA data from the experiment in air looks very similar to the data from the test in nitrogen. The DSC data, however, is substantially changed. The second weight loss is now accompanied by an exotherm, rather than the endotherm seen in the nitrogen atmosphere. In the oxidizing atmosphere, the CO evolved from the sample, immediately reacts with oxygen in the atmosphere to form CO. This exotherm seen in the DSC data is evidence of this reaction. Dynamic Normalization Provides Accurate Transition Heat Flows DSC data is routinely normalized by dividing the heat flow signal by the sample weight. This normalization provides the ability to quantify heats of fusion, reaction, etc in units of energy per unit mass so that samples of different sizes can be easily compared. The sample weight used in this calculation is typically the initial weight of the sample. However, many samples exhibit weight loss prior to the transition of interest, so use of the initial weight could induce substantial error. Using its unique Dynamic Normalization algorithm, the SDT enables the user to specify how the DSC signals are to be normalized. Figure 7 shows DSC data from 3 sequential heats of Sodium Chloride using standard normalization. It would seem that the magnitude of the melting endotherm decreases with each heat. However, the TGA data shown in figure 8 shows that there is a weight loss associated with the volatilization of NaCl that occurs upon melting. The result is that in each sequential heat, there is less sample weight. The DSC data shown in figure 8 illustrates the benefit of Dynamic Normalization. Here the sample weight for transition normalization was taken as the weight at the beginning of each transition, and indeed all three heats show reproducible heats of fusion.

Evaluation of Transitions Over a Wide Temperature Range provides evaluation of materials up to 15 C. This ability to obtain measurements at higher temperatures is most useful for inorganic materials such as cements, clays, ceramics, superconductors, and metals. Figures 9-1 show typical examples. Figure 9 shows DSC-TGA results for soda ash. TGA data shows the loss of water, as well as the onset of the vaporization process at higher temperatures. The excellent DSC sensitivity of the SDT 96 enables us to see not only the endotherms associated with the water loss, and the large melting transition, but also the subtle endotherms associated with the two polymorphic transitions. Kaolin, or china clay as it is often called, is an industrial mineral widely used in the paper, ceramics, catalyst, paint, and polymer industries. It is an aluminosilicate material that is used as a filler or coating material to provide enhanced performance including improved brightness and opacity. Figure 1 shows kaolin data from an SDT experiment. The TGA curve shows both the loss of free water just above room temperature, as well as the expulsion of water from the crystal lattice. The TGA derivative curve facilitates selection of analysis limits for these two weight losses, both of which correspond with endotherms in the DSC data. Also seen in the DSC data is a sharp endothermic peak associated with recrystallization. Temperature and Enthalpy Accuracy and Reproducibility Key to any DSC measurement is the ability to accurately and reproducibly measure temperatures and enthalpies of transitions. Figure 11 and Table 1 demonstrate the superior DSC performance of the SDT 96. Figure 11 shows SDT data for multiple runs of zinc, aluminum, sodium chloride, and gold. These four materials cover a wide temperature range and hence are an excellent test of accuracy and reproducibility. Table 1 shows the results from eight runs in tabular format. Enthalpy accuracy and precision (reproducibility) for these four materials are better than %. Excellent Performance Over a Wide Temperature Range While the SDT 96 design has been optimized to provide the best possible DSC performance at temperatures above C, good DSC performance can be achieved at lower temperatures. An example of this lower temperature performance (of both DSC & TGA signals) is the analysis of gypsum. One of the uses of gypsum (CaSO 4 H O) is in the manufacture of portland cement, where 5% gypsum is used to reduce the rate of setting. The gypsum is added to the fused clinker during processing, and the two are milled to obtain uniform mixing and the required particle size. During this milling process, the thermal energy generated may cause partial dehydration of the gypsum to hemihydrate (CaSO 4.5H O). This adversely affects the rate of setting as well as the long term properties of the cement. The ability to study this two step dehydration is critical to insure optimum end use properties. Figure 13 shows SDT data for gypsum. Both the DSC and TGA curves clearly show both steps in the dehydration process. Heat Flow (W/g) Heat Flow (W/g) 1-1 Figure 1 Kaolin -.6347% Free Water (.1366mg) 5.5 C 9.198J/g 115.76 C -3 85 4 6 8 1 1 Figure 11 Temperature & Enthalpy Accuracy and Reproducibility - 5-5 -1-15 Zinc Aluminum Figure 1 Temperature & Enthalpy Accuracy and Reproducibility - Figure 13 Gypsum - 11.4 C 13.33% Water (.869mg) Sodium Chloride 999.11 C 111.5J/g Deriv. (%/ C).13.11.9.7.5.3.1 Gold 4 6 8 1 1 Run # Zinc Aluminum NaCl Gold 1 18.9 J/g 4. J/g 474. J/g 63.8 J/g 11.7 395.1 475.4 61.9 3 11. 393.7 471.5 64.7 4 19. 394.6 47.1 63.6 5 11.6 395. 47.3 64.7 6 19.7 386.8 47.9 63. 7 18.5 396. 478. 64.6 8 17.3 389.7 475.7 64.1 Average 19.4 J/g 393.9 J/g 473.8 J/g 63.8 J/g Std Dev 1. 4..6 1. Known Value 18.7 J/g 4.1J/g 48. J/g 63.7 J/g Accuracy.6% 1.6% 1.3%.% Precision 1.1% 1.%.5% 1.5% Heat Flow (W/g).5 -.5-1 -1.5 15.31% (1.646mg) 13.69 C 151.(88.1)J/g 139.65 C 146.3 C 136.8J/g Deriv. (%/ C).8.6.4. 4.744% (.511mg) 15 1 95 9 15 95 85 75 5 1 15 5

Specifications Temperature Range: Sample Capacity (max): Balance Sensitivity: Calorimetric Accuracy: Calorimetric Precision: Heating Rate: Purge Gas Rate: Purge Gases: Sample Pans: Temperature Calibration: Furnace Cooling: Ambient to 15 C** mg (35 mg including sample holder system).1µg ± % (based on metal standards) ± % (based on metal standards).1 to 1 C/min in.1 C/min increments (ambient to 1 C).1 to 5 C/min in.1 C/min increments (ambient to 15 C) up to 1 liter/minute Nitrogen, air, oxygen, argon, helium. 5 millitorr vacuum. Platinum: 4µl, 11µl; Alumina: 4µl, 9µl* 1 to 5 points, based on metal standards Forced air; 15 to 5 C in less than 3 minutes Thermocouples: Platinum/Platinum-Rhodium (Type R) Data Collection Rate: * **.5 to 1 sec/point 9µl alumina pans recommended for DSC studies DSC performance optimized for -15 C DTA-TGA Capabilities The SDT 96 can easily be configured to provide DTA data for comparison with historical records. The high T sensitivity (.1 C) allows detection of small endothermic and exothermic transitions. Results are expressed either in C or in µv. TA Instruments Commitment The SDT 96 is designed and engineered to assure easy, reliable, trouble-free operation. It is supported by a full range of services, including an applications laboratory, publications, training courses, seminars, applications CD s, internet website, and a telephone Hotline for customer consultation. Highly qualified service personnel specializing in thermal analyzer/rheometer maintenance and service are available throughout the world. All of these items reflect TA Instruments commitment to providing innovative thermal analysis & rheology products and related services that deliver the maximum value for your investment. For Information or to place an order, contact the office near you: New Castle, DE USA Telephone: 3-47-4 Gent, Belgium Telephone 3-9-79-89 Leatherhead, England Telephone: 44-137-36363 Paris, France Telephone: 33-1-348946 Alzenau, Germany Telephone: 49-63-344 Tokyo, Japan Telephone: 81-3-345-981 Madrid, Spain Telephone: 34-91-661-84-48 Rydalmere, Australia Telephone: 61-9933-175 Milano, Italy Telephone: 39741-1 For a complete list of international distributors visit our website at http://www.tainst.com Thermal Advantage Software, Dynamic Normalization, TA Instruments and the PET curve logo are trademarks of TA Instruments, Inc. Specifications are subject to change. TA-69B PRINTED IN U.S.A.