www.kem-kueppers.com info@kem-kueppers.com



Similar documents
Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter

Regulations for custody transfer measurements: meeting the needs? Focus on liquid flow measurement systems/applications

191: Calibration and Standards in Flow Measurement. Richard Paton National Engineering Laboratory, Scotland, UK 1 GENERAL PRINCIPLES

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

Hydraulic control unit series

Calibration Certificate

HIGH PRESSURE TECHNOLOGY HYDRAULICS PNEUMATICS TESTING EQUIPMENT

Calibration of flow meters for liquids and gases

GOOD PRACTICE GUIDE THE CALIBRATION OF FLOW METERS

RITTER Multiple Sonic Nozzle Calibration System

CONTOIL DFM 8EDM. Table of contents. Mounting and operating instructions

Michael Montgomery Marketing Product Manager Rosemount Inc. Russ Evans Manager of Engineering and Design Rosemount Inc.

COUNTERBALANCE VALVES

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Leak detection of systems

KEM - Your Partner for Flow Measurement Technologies

Turbine Flow Sensor Series VTR

2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version

Drain Back systems Made in Germany

The Unique Accelabar Flow Meter

D634-P Series Direct Drive Proportional Valve with Integrated 24 V Electronics ISO 4401 Size 05

Operating Instructions Hand pallet trucks HU Profi. Issue

Open center control block in monoblock design MO-40

TEMPERATURE MEASURING GALVANIC SEPARATORS CONVERTORS, PRESSURE MEASURING

In addition, a number of auxiliary options are available (para 2.7) as well as optional slices for special requirements (para 2.8).

Digital inductive conductivity transmitter

Radial piston pumps type R and RG

PUMP AND MOTOR DIVISION

How To Test A Titrette And Digital Burette

High Precision Measurement of the Target Mass of the Daya Bay Neutrino Detectors

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

Inventory Control. Inventory Control Tank & Silo Weighing

THE USE OF A CORIOLIS FLOW METER FOR MEASURING MOLASSES PRODUCTION IN A SUGAR MILL. ABSTRACT

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Steering unit. Table of contents. Features RE 11872/ Type LAGL. Frame sizes 500 to 1000 Component series 1X Maximum flow 80 l/min

Fundamentals of Mass Flow Control

Unit 24: Applications of Pneumatics and Hydraulics

Subminiature Load Cell Model 8417

AVL FUEL MASS FLOW METER & FUEL TEMPERATURE CONTROL

OPTIMASS 6000 Technical Datasheet

Additional Requirements

Hilger u. Kern / Dopag Group

CERTIFICATE of Product Conformity (QAL1 )

PVS 185, 600, 1200, 1800, 2700 Series Portable Purification Systems

HOW THE CONTAMINATION IS MEASURED CONTAMINATION CLASSES ACCORDING TO ISO 4406:1999

Fault codes DM1. Industrial engines DC09, DC13, DC16. Marine engines DI09, DI13, DI16 INSTALLATION MANUAL. 03:10 Issue 5.0 en-gb 1

Operating Instructions

Fiscal Measurement Natural Gas

How To Use A Flowmeter

Unit 24: Applications of Pneumatics and Hydraulics

Assisted lift operated 2/2-way solenoid valves Type EV250B

Gravimetric determination of pipette errors

Hydraulic Control Solutions

Duplex Filters 40/160 LD /160 LDN Industrial Filters Accumulators. Filters for inline installation for continuous operation

OPTIMASS 1400 Technical Datasheet

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

Automatic Back-Flushing Filter AutoFilt RF9.

Overflow valve with thread connection

MAGTROL. ZS Series Load Cell. ZS Data Sheet. Features. Description

HERZ-Thermal Actuators

Bulk Flow Meter LB 442 P R O C E S S C O N T R O L

Precision Mass Flow Metering For CVD Applications.

Specials. designed. 3rd edition 2015 English. for scientists 1

Accreditation according to ISO/IEC in Europe. Historic EA Europeing Accreditation Assessment Experience from Technical assessment

Ergo-Pro Single Line Solar Station Installation and Operating Instructions

Procon Engineering. Technical Document PELR TERMS and DEFINITIONS

Entrained Gas Diagnostic with Intelligent Differential Pressure Transmitter


MANTA Piston Distributor for Oil and Fluid Grease

Dynamic Process Modeling. Process Dynamics and Control

Standard Hydraulic Piping Flushing Procedure

German engineering under high pressure

Flow controller with integrated control valve (PN 16, 25, 40*) AFQM, AFQM 6 - return and flow mounting

Terminology and Symbols in Control Engineering

Signature and ISX CM870 Fuel System

IN LINE FLOW-METER CALIBRATION ADVANCE METHODS AND SOLUTIONS

AN INSTRUMENT FOR GRAVIMETRIC CALIBRATION OF FLOW DEVICES WITH CORROSIVE GASES. J. O. Hylton C. J. Remenyik Oak Ridge National Laboratory *

Certificate: / 29 April 2014

Certificate: / 20 August 2013

Hydraulic Troubleshooting PRESENTED BY

Correcting a Coriolis Meter for Two Phase Oil & Gas Flow

ZHM Series Installation and Operating Instructions

Emergency safety showers Part 3: Body showers for production and logistic sites

METHOD OF TEST FOR DETERMINATION OF PERMEABILITY OF GRANULAR SOILS

PBX Series Quick Fit Connector Bimetallic Steam Traps

A MTR FUEL ELEMENT FLOW DISTRIBUTION MEASUREMENT PRELIMINARY RESULTS

Pumps: Convert mechanical energy (often developed from electrical source) into hydraulic energy (position, pressure and kinetic energy).

Oil / Air Cooling Units for mechanical engineering and mobile hydraulics

Initial Experiments of a Novel Liquid Desiccant Dehumidifier for Industrial and Comfort Air Conditioning Systems

Re-engineering and function testing at Handtmann Zittau WELCOME

A basic introduction to steam

EQUIPMENT CALIBRATION/MAINTENANCE

Operating instructions Platform/floor scales

Advanced Differential Pressure Flowmeter Technology V-CONE FLOW METER TECHNICAL BRIEF

Turbine Flowmeter Vision 1000 Flowrates 0,1-2,5L/min. Turbine Flowmeter Vision 2000 Flowrates 0,5-35L/min

Transcription:

www.kem-kueppers.com info@kem-kueppers.com Calibration of flow meters according to DIN EN ISO/IEC 17025:2005

Introduction... 2 Calibration laboratory... 3 Description of the calibration process... 3 Calibration according to the weighing-time procedure... 4 Hydraulic circuit... 8 Performance data for the permanent laboratory...8 DAkkS Accreditation...9 Table of contents

2 Calibration is the professional method for obtaining precise and accurate information about the accuracy of measuring equipment. As a manufacturer of flow meters, we prepare individual calibration records for all sensors; by request also for two flow directions and different viscosities. Our calibration records contain: K-factor and linearity error for the entire measuring range K-factor and linearity error at various measuring points You have the choice of our gravimetric or volumetric test stands for the calibration. The gravimetric calibration stand is the heart of our DAkkS- DKD-AHT311 (EA-4/02) calibration laboratory. The laboratory is accredited according to ISO 4185 by the accreditation authority of the German Calibration Service

3 Calibration laboratory Calibration procedure According to ISO 4185: Measurement of liquids in closed pipelines weighing procedure Description of the calibration process This dynamic calibration procedure uses the weighing-time system (self-indicating), i.e. the corresponding required volume of liquid with a specified weight is measured in the time unit under consideration of the specific weight and viscosity, while the specified temperature of the test medium is kept constant with high accuracy. For the exact determination of the volume flow, an online density measuring device from the company Anton Paar, model L-Dens 417, is used in parallel to record the density for each measuring point. The sensor itself is equipped with internal temperature measurement (± 0.1 C), so that the density can be determined exactly (± 0.0001 kg/m^3). Therefore the same also applies to the resulting calculated volume. 1 2 3 4 5 6 7 8 9 10 11 12 A A B B C C D D E E F F G G H 1 2 3 4 5 6 7 8 Fig. 8-1: Schematic drawing of the weighing system s: deflection of the lever arm; 1: storage tank; 2: centrifugal pump; 3: filtering unit; 4: tube-bundle-heat exchanger; 5: control valves; 6: specimen; 7: balancing valves; 8: pneumatikator for closing and opening the valve at the weighing tank bottom (11); 9: baffle plate for returning the kinetic/potential energy of the medium of the housing of the weighing tank (10); 10: weighing tank; 11: valve for opening/closing the weighing tank; 12: rigid, mechanical linkage; 13: test stand frame; 14: weighing cell; 15: A/D transformer; 16: timer/counter; 17: DOP software; 18: stellite cutting edge; 19: steel cable connection to the weighing cell; 20: weighing arm; detail A, B, C: storage of cutting and saddle

4 Gravimetrischer Kalibrierstand AHT311 (EA-4/02) Measuring range: 0,016 to 2,000 l/min Calibration viscosities: up to 100 mm/s Measuring uncertainty: 0,05%-0,1% of the measurement Calibration according to the weighing time procedure During calibration, the time is measured in which a previously determined precision weight (established mass) is compensated by the calibration medium after it flows through the specimen. An electronic msec timer precisely captures the duration of each weighing process. The timer oscillation is 1 MHZ. In order to guarantee the high accuracy and reproducibility of the measurements, all components of the calibration stand are harmonised for the application. The self-indicating weighing system described above is used to measure the time in which a previously established calibration fluid is collected in the weighing tank after it flows through the specimen. The weighing tank is suspended from a weighing arm, at the end of which is a load cell with accuracy C3 according to OIML R60. An electronic deflection system is used, which drastically reduces the lever stroke (see Fig. 8-1). The connection between the weighing arm and load cell is rigid, so that the risk of a time offset at this point is eliminated as well. The measuring signal from the load cell is evaluated by a high-quality digital measuring amplifier for dynamic weighing processes and displayed on the computer with DOP software which is used for further processing. To counteract undesirable friction forces, the scale is stabilised by self-aligning Stellite blades and Wallex saddles. This guarantees a constant, unchanging lever arm. The sensitivity of the entire system in response to weight changes is unusually high. An electronic millisecond counter is used to measure the precise duration of each weighing process. The counter oscillation is 1 MHZ. The display is in thousandths of a second. For the calibration of pulse-generating flow meters, such as turbine flow meters, a pulse counter captures the current and overall pulse rate. The pulse counter is linked to the millisecond counter. All components are designed especially for this measuring application and guarantee optimum flow conditions with the highest reliability.

5 Flow rate The liquid in the reservoir is continuously pumped through a closed hydraulic circuit (see Fig. 8-2). It first flows through the filter (1) and heat exchanger (2), which keeps the temperature and therefore the viscosity of the calibration medium constant. Then the test liquid flows through the control valves (3), density measuring device (4), specimen (5), balancing valve (6), weighing tank (7) and finally back into the reservoir (8). A deflection cone at the intake of the weighing tank ensures even distribution of the calibration liquid in the tank. actuator of drain valve timer balancing valve (6) weighing arm A/D transformer specimen (5) load cell density measuring device (4) 7 control valves (3) DOP software heat exchanger (2) filter (1) pump 8 Fig. 8-2: Weighing system flow rate Preparing for the weighing process The control valves (1) are set to the desired flow rate. The duration of calibrating the measuring point is determined by entering weight values in the DOP software (2) (setpoint 0 = tare weight; setpoint 1 = calibration weight) (Fig. 8-3).. actuator of drain valve timer balancing valve weighing arm A/D transformer specimen density measuring device load cell DOP software (2) control valves (1) heat exchanger filter pump Fig. 8-3: Weighing system preparing for the weighing process

6 Forerun/taring phase Pressing the start button sets the timer (1) to zero and closes the drain valve (2) on the weighing tank, launching the forerun/taring phase of the calibration process (Fig. 8-4). actuator of drain valve timer (1) balancing valve weighing arm A/D transformer specimen density measuring device load cell DOP software control valves heat exchanger drain valve (2) filter pump Fig. 8-4: Weighing system taring phase End of the forerun/taring phase - start of the weighing process The load cell (1) measures the weight increase caused by the calibration liquid flowing into the weighing container (2) and sends its signal to the A/D transformer (3). When the weight value stored under setpoint 0 is reached, the A/D transformer (3) activates the timer (4) in the test stand. This is the beginning of the actual weighing process. The taring phase zeroes the scale, compensating for dynamic effects. (Fig. 8-5) actuator of drain valve timer (4) balancing valve weighing arm A/D transformer (3) specimen density measuring device (2) load cell (1) DOP software control valves heat exchanger filter pump Fig. 8-5: Weighing system start of the weighing process

7 End of the weighing process The weighing process ends and time measurement stops as soon as the specified weight value (setpoint 1) is reached. The measured time is displayed to one thousandth of a second. Now the mass flow rate per unit of time is determined from the measured time and calibration weight (setpoint 1 setpoint 0) (Fig. 8-6). actuator of drain valve timer balancing valve weighing arm A/D transformer specimen density measuring device load cell DOP software control valves heat exchanger filter pump Fig. 8-6: Weighing system end of the weighing process Emptying the weighing tank for a new weighing process When a weighing process has been completed, the weighing tank (1) is emptied automatically (Fig. 8-7). This is done in less than 25 seconds even with the maximum flow rate. A new weighing process can follow immediately after emptying. actuator of drain valve timer balancing valve weighing arm A/D transformer density measuring device specimen (1) load cell DOP software control valves heat exchanger filter pump Fig. 8-7: Weighing system emptying the weighing tank for a new weighing cycle

8 Hydraulic circuitf 1. Drain valve for leakage-free operation and high flow rates. With the maximum flow rate, the weighing tank can be emptied in 25 seconds or less without reducing the flow rate. 2. The vapour seals at the top and bottom of the weighing chamber prevent vapour losses. The seals are fluid and free of wear. 3. The stainless steel weighing tank has an overflow for the maximum flow rate. 4. Backpressure regulation prevents cavitation, which can occur in case of liquids with a low viscosity. 5. The flow regulator works with valves developed by COX Instrument for precise flow rate values, ensuring high calibration accuracy. 6. The heat exchanger ensures for a constant temperature of the calibration medium 7. The filter prevents dirt from impairing the performance of the specimen or accumulating in the collection container. Flow turbulences are also prevented by the filter. 8. Corrosion-resistant precision centrifugal pump. The pump guarantees a constant flow rate with minimal pulsation. 9. Filler neck. The tank can be filled manually or by external pressure fuelling. 10. The viewing window allows the user to inspect the collection container and drain valve at any time. A leak in the drain valve can be identified immediately. 11. The reservoir is made of stainless steel and is self-draining. This is important when changing liquids. Permanent Laboratory Measurement or calibration object Measuring range/ measuring span Measuring conditions/ processes Smallest assignable measuring uncertainty Notes Flow rate measurements Mass m of flowing liquids Measured flow rate dm/dt of flowing liquids Volume V of flowing liquids Flow rate dv/dt of flowing liquids 0,9 kg to 8 kg 90 kg to 600 kg Weighing process Dynamic 0,015 kg/min to 1500 kg/min 1 l to 10 l 100 l to 800 l Weighing process Dynamic 0,016 l/min to 2000l/min Conversion via the density 0,05 % 0,1 % Medium being measured; liquids with a density of p = 650 kg/m² to p = 1000 kg/m² and a viscosity of v = 1 mm²/s v = 100 mm²/s 1) The smallest assignable measuring uncertainties are established according to DAkkS-DKD-3 (EA-4/02). These are extended measuring uncertainties with a 95% coverage probability and, unless anything different is specified, have the coverage factor k=2. Measuring uncertainties without specified units are relative values referring to the measurement, unless otherwise noted.

Contact KEM Headquarter Liebigstraße 5 85757 Karlsfeld Deutschland T. +49 8131 59391-0 F. +49 8131 92604 info@kem-kueppers.com KEM Service & Repairs Wettzeller Straße 22 93444 Bad Kötzting Deutschland T. +49 9941 9423-0 F. +49 9941 9423-23 info@kem-kueppers.com For more distributors & partners, please visit: www.kem-kueppers.com KEM Küppers Elektromechanik GmbH Liebigstraße 5 D-85757 Karlsfeld Tel +49 8131 59391-0 Fax +49 8131 92604 Copyright KEM, Änderungen und Irrtümer vorbehalten, DAkkS_D_E_150914_E001