AMP 200N1 LOW FREQUENCY SIGNAL SOURCE DC (0HZ) TO 250KHZ, 800W



Similar documents
TRANSIENT EMISSION SET AUTOMOTIVE TRANSIENT EMISSION MEASUREMENTS AS PER ISO

NETWAVE SERIES (3-PHASE) THREE-PHASE MULTIFUNCTIONAL AC/DC POWER SOURCES

VDS 200Q SERIES 4-QUADRANT VOLTAGE DROP SIMULATOR - BATTERY SIMULATOR AND DC VOLTAGE SOURCE

VDS 200N SERIES VOLTAGE DROP SIMULATOR - BATTERY SUPPLY SIMULATION AND DC VOLTAGE SOURCE

UCS 500N7.2 MULTIFUNCTIONAL TRANSIENT SIMULATOR FOR RENEWABLE ENERGY

UCS 500N7 MULTIFUNCTIONAL TESTGENERATOR FOR TRANSIENTS (EFT/BURST, SURGE & POWER FAIL) UP TO 7KV

Load Dump Pulses According to Various Test Requirements: One Phenomenon Two Methods of Generation A Comparison

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 1

FREJA 300 Relay Testing System

Multi-Range Programmable DC Power Supplies 9115 Series

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

NIKY and NIKY S. UPS SINGLE-PHASE from 600 to 3000 VA GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

SINEAX U553 Transducer for AC Voltage

帝 聞 企 業 股 份 有 限 公 司 DEE VAN ENTERPRISE CO., LTD. SP DSL-20WA Revision: A Date: FOR AC-DC LED DRIVER MODEL NO.

Multi-Range Programmable DC Power Supplies 9115 Series

Analog signal converters CC-E I/I Current / current isolators

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

Quick Connect. quick - simple - efficient.

LogicLab s.r.l Via della valle Carate Brianza (MI) Tel Fax

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

KONSTANTER SPL / SPL Programmable Electronic Load

DCS Series 1 kw, 1.2 kw, & 3 kw

7.5 Watt AC-DC Switch Power Supply

Photovoltaic Solar Energy Unit EESFB

DS 600. A contact free flux gate based current measurement sensor 600A rms

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Power Meter Series 700

UMEC International Corporation

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date Rev.

Single Output Switching Power Supply

AC/DC Power Modules C B. TML Series, 20 & 40 Watt. Features. 20 Watt Models

EMC TEST SYSTEMS FOR AUTOMOTIVE

DATA SHEET. TDA8560Q 2 40 W/2 Ω stereo BTL car radio power amplifier with diagnostic facility INTEGRATED CIRCUITS Jan 08

User manual Rev. 1.2 (17/04/2015)

INTEGRATED CIRCUITS DATA SHEET. TDA W BTL mono audio amplifier. Product specification File under Integrated Circuits, IC01

Three-phase monitoring relay CM-PFE

Equivalent Circuit. Operating Characteristics at Ta = 25 C, V CC = ±34V, R L = 8Ω, VG = 40dB, Rg = 600Ω, R L : non-inductive load STK4181V

Energy Management Energy Meter Type EM23 DIN

Actuator-Sensor-Interface

Power Supplies 3. SDN-P DIN Rail Series

Power Electronics Testings

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

LM833 LOW NOISE DUAL OPERATIONAL AMPLIFIER

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

LM381 LM381A Low Noise Dual Preamplifier

5320A Multifunction Electrical Tester Calibrator. Verify and calibrate electrical test tools with a single instrument

Rated Power(W) 8W 2. EG-LED W 3. EG-LED W

LM1036 Dual DC Operated Tone/Volume/Balance Circuit

High Power Programmable DC Power Supplies PVS Series

Current Probes. User Manual

CPCI-3U-AC-300W-R. Rugged 300W AC Input 3U CompactPCI Power Supply. Electrical Specification for: Telkoor Part Number:

J TB/TW Temperature limiter, temperature monitor

TDA2004R W stereo amplifier for car radio. Features. Description

HFE1600 Series 1600W 1U Hot Swap Front End Power Supplies

Kit 27. 1W TDA7052 POWER AMPLIFIER

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

SELECTION GUIDE INPUT CHARACTERISTICS. Voltage set point accuracy. Overall voltage error. Temperature coefficient of output voltage (slope)

APPENDIX A PIN-OUT OF RJ12 / RJ45 CONNECTORS. RJ12 connectors

STRATO LED Drivers 70W, Single output

Power Electronics Testings

BRAZILIAN AUTOMOTIVE INDUSTRY AT A GLANCE

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

PIN CONFIGURATION FEATURES ORDERING INFORMATION ABSOLUTE MAXIMUM RATINGS. D, F, N Packages

3466 Building Energy Management Training Systems

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

EFC Frequency converters

Programmable Power Supply HM7044

D1U54P-W HxxC Series 54mm 1U Front End AC-DC Power Supply Converter PRODUCT OVERVIEW FEATURES

Linear Parameter Measurement (LPM)

Obsolete Product(s) - Obsolete Product(s)

Selection Guide to Clamp-On Current Probes

Digital Clamp-on DMMs with uncompromising performance

Safety technique. Emergency stop module BO 5988 safemaster

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

MPC 4. Machinery Protection Card Type MPC 4 FEATURES. Continuous on-line Machinery Protection Card

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Current and Energy. Measurement Technology

TDA W CAR RADIO AUDIO AMPLIFIER

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Cond-IS RF Conducted Immunity System

Model UT713 OPERATING MANUAL

Broadband Telecommunications Drop Amplifier

R&S SMZ Frequency Multiplier Specifications

Panel Meters and Controllers Modular Panel Meter Type EDM 35

DATA SHEET. TDA1518BQ 24 W BTL or 2 x 12 watt stereo car radio power amplifier INTEGRATED CIRCUITS

650W Single Output Power Supply

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

DVT913 TV CHANNEL CONVERTER

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

VIBROCONTROL Sensitive Machine Monitoring

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

Programmable Single-/Dual-/Triple- Tone Gong SAE 800

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Transcription:

AMP 200N1 LOW FREQUENCY SIGNAL SOURCE DC (0HZ) TO 250KHZ, 800W SELON LES NORMES SUIVANTES... > Chrysler CS-11809 (2009) > Chrysler CS-11979 > Chrysler DC-11224 Rev.A > DaimlerChrysler DC-10614 > DaimlerChrysler DC-10615 > DaimlerChrysler DC-11224 > Fiat 9.90110 > Ford EMC-CS-2009.1 > Ford ES-XW7T-1A278-AC > GLloyd VI-7-2 > GMW 3097 (2006) > GMW 3172 > ISO 11452-10 > ISO 11452-8 > EMC-CS-2010JLR V1.1 (2011-01) > MAN 3285 > MBN 10284-2 > Nissan 28400 NDS 02 > PSA B21 7110 Rev.C, Ad. 2010-05 > Renault 36.00.808/--G > Renault 36.00.808/--H >... AMP 200N1 - LOW-FREQUENCY SIGNAL SOURCE FOR SUPPLY SIMULATION AND MAGNETIC FIELD TESTING The AMP 200N1 has been designed as a low-frequency signal source to generate sinusoidal signals used to simulate ripple noise and ground shift noise as required by a variety of standards in the avionics, military and automotive industry. The AMP 200N1 is controlled by either the NetWave (for testing avionics, military and nautic standard requirements, e.g German Lloyd VI-7-2) the AutoWave for automotive testing such as e.g. Ford EMC-CS-2009.1. Additionally, the AMP 200N1 can be used to generate magnetic fields by means of a radiation loop or small Helmholtz coils as per various standards. HIGHLIGHTS > Built-in DDS to generate sinusoidal signals up to 250kHz > Built-in LF amplifier, 800W > Output voltage max. 140V p-p, 50V rms > Output current max. 16A rms > Supports German Lloyd VI-7-2 > Supports magnetic field tests > Short-circuit protected DOMAINES D'APPLICATION AUTOMOBILE MILITAIRE AÉRONAUTIQUE www.emtest.com EM TEST > PAGE 1/5

TECHNICAL DATA AMPLIFIER OUTPUT CHARACTERISTICS Signal power Output voltage Output current DC current (H-field) Total Harmonic Distortion (THD) Protection DC - 250kHz 800W (nominal) 50Vrms, 140V(p-p), max. 200kHz 45Vrms, 200kHz - 250kHz Max. 16Arms (voltage low-range 25V) Max. 8Arms (voltage high-range 50V) 27ADC < 0.1% - Short circuit - Overtemperature STANDARD TESTS SUPPORTED WITH THE NETWAVE-SERIES STANDARD TESTS AS PER RCTA DO-160 E/F/G (SECT. 18) Cat. R/K Cat. R/B/Z AC (5V - 170V), 700Hz - 32kHz DC (14V/28V/270V), STANDARD TESTS AS PER ABD0100.1.2 G, CONDUCTED IMMUNITY Cat. R/K Cat. R/B/Z AC (5V - 110V), 700Hz - 32kHz DC (14V/28V/270V), SIGNAL GENERATOR OUTPUT CHARACTERISTIC (BUILT-IN) Output voltage DC offset DC, 10Hz - 250kHz (sinusoidal) +/-10V 0-10V, programmable, to control external DC amplifier STANDARD TESTS AS PER ABD0100.1.8 E, CHAPT. 16, RIPPLE VOLTAGE 0.004Vpp - 4.0Vpp STANDARD TESTS AS PER ABD0100.1.8.1, RIPPLE VOLTAGE 0.6Vpp - 4.0Vpp STANDARD TESTS AS PER ABD0100.1.8.1, VOLTAGE DISTORTION Tests AC SVF 107/303, SCF 107, SVFH 107 Tests DC LDC 103 Closed loop www.emtest.com EM TEST > PAGE 2/5

STANDARD TESTS SUPPORTED WITH THE NETWAVE-SERIES STANDARD TESTS AS PER MIL STD 461 E/F/G CS 101 CS 109 RS 101 Voltage ripple AC/DC, 30Hz - 150kHz Structure current, 60Hz - 100kHz H-Field (Army, Navy), 30Hz - 100kHz / Calculation method STANDARD TESTS AS PER MIL-STD-704 A/B/C/D/E/F Tests AC SAC 106, SVF 106, SXF 106 Tests DC LDC 103/104, HDC 103/104 Substitution method STANDARD TESTS AS PER GERMAN LLOYD VI-7-2, CONDUCTED IMMUNITY Test AC Test DC Table 3.30 (up to 230V), 100Hz - 10kHz Table 3.29, 50Hz - 10kHz / Calculation method STANDARD TESTS WITH AUTOWAVE SAE J1113-2 - CONDUCTED IMMUNITY Injected current / Substitution method 15Hz - 80kHz (250kHz) 0.15Vpp / 0.5Vpp / 1.0Vpp / 3.0Vpp Limited to max. 1A during test STANDARD TESTS WITH AUTOWAVE SAE J1113-22 - RADIATED MAGNETIC FIELD Substituition method 15Hz - 30kHz 10uT - 100uT ISO 11452-8 - MAGNETIC FIELD Calculation method; verified by Loop sensor 15 Hz - 150 khz 0.3A/m - 1,000A/m ISO 11452-10 - CONDUCTED IMMUNITY Source impedance / Substitution method 15Hz - 250kHz 0.15Vpp / 0.5Vpp / 1.0Vpp / 3.0Vpp less than 0.5ohm STANDARD TESTS AS PER FORD EMC-CS-2009.1 RI 140 RI 150 CI 210 CI 250 Magnetic field Immunity, 50Hz - 100kHz Coupled Immunity, 1kHz - 100kHz Immunity to Continuous Power Line Disturbances, 50Hz - 100kHz Immunity to Ground Voltage Offset Continuous, 2kHz - 100kHz Immunity to Ground Voltage Offset Transient, Sequence 1-4 / Calculation method www.emtest.com EM TEST > PAGE 3/5

MORE STANDARD TESTS... GENERAL DATA ADDITIONAL AUTOMOTIVE STANDARDS Chysler LLC DC-10615 (Rev. E, 2007-12) DC-11224 (Rev. A, Add., 2008-04) CS-11809 (2009-05) CS-11979 (Change A, 2010-04) DaimlerChrysler DC-10614 (Rev. A, 2004-01) DC-10615 (Rev. B, 2004-08) DC-10615 (Rev. C, 2006-04) DC-10615 (Rev. D, 2007-05) DC-11224 (Rev. A, 2007-05) FIAT 9.90110 (Rev. 11, 2003-07) 9.90110 (Rev. 12, 2006-02) 9.90110 (Rev. 13, 2007-03) 9.90111 (Rev. 1, 2010-05) Ford ES-XW7T-1A278-AC (2003-10) General Motors GMW 3097 (Rev. 4, 2004-02) GMW 3097 (Rev. 5, 2006-07) IVECO 16-2119 (2008-11) 16-2119 (2010-05) Jaguar/LandRover EMC-CS-2010JLR (2010-06) EMC-CS-2010JLR V.1.1 (2011-01) Mitsubishi ES-X82114 (Rev. C, 2007-04) ES-X82114 (Rev. D, 2009-03) ES-X82115 (Rev. C, 2007-04) ES-X82115 (Rev. D, 2009-03) Mercedes-Benz MBN 10 284-2 (2008-03) Nissan 28 401 NDS02 [2] (2003-10) 28 401 NDS02 [3] (2006-03) 28 401 NDS02 [4] (2008-08) PSA B21 7110 (Rev. A, 2004-07) B21 7110 (Rev. B, 2005-05) B21 7110 (Rev. C, 2008-03) B21 7110 (Add. Rev. C, 2010-05) Renault 36.00.808/--G (2004-02) 36.00.808/--H (2007-06) 36.00.808/--J (2008-04) 36.00.808/--K (2009-03) 36.00.808/--L (2010-12) Tata Motors TST/TS/WI/257 (2008-07) Volkswagen VW TL 825 66 (2006-02) VW TL 825 66 (2011-05) Volvo STD 515-0003 (Rev. 3, 2008-03) STD 515-0003 (Rev. 4, 2009-10) INTERFACE Serial interface GENERAL DATA Dimensions Weight Supply voltage Framebus to AutoWave or NetWave 19", 6HU (500mm x 449mm x 286mm) Approx. 36kg Input power Max. 1,000W Fuses Cooling Temperature 10 C - 40 C Rel. humidity MEASUREMENTS (OPTIONAL) MU-AMP 200N 115V or 230V +10/-15%, 50/60Hz 2 x 6.3AT (115V) or 2 x 3.15AT (230V) Active cooling, air ventilation Max. 85%, non-condensing Optional built-in measuring unit; Frequency-selective instrument for voltage, current and magnetic field 10Hz - 250kHz Accuracy Better than 5% Current measurement Voltage measurement ACCESSORIES Radiating Loop Loop Sensor CN 200N1 External with current clamp: Range 100mV/A: 1mA - 30A rms Range 10mV/A: 10mA - 300A rms 17mV - 70V rms 120mm radiation loop for magnetic field testing as per Ford EMC-CS-2009.1, RI 140 To measure the magnetic field strength Transformer assembly with built-in 0.5ohm/250W resistive load as per Ford EMC-CS-2009.1, German Lloyd VI-7-2 and other standards www.emtest.com EM TEST > PAGE 4/5

COMPÉTENCE DANS TOUS LES DOMAINES CONTACTEZ DIRECTEMENT EM TEST Suisse EM TEST (Switzerland) GmbH > Sternenhofstraße 15 > 4153 Reinach > Switzerland Téléphone +41 (0)61/7179191 > Fax +41 (0)61/7179199 Internet: www.emtest.ch > E-mail: sales.emtest@ametek.com Allemagne EM TEST GmbH > Lünener Straße 211 > 59174 Kamen > Deutschland Téléphone +49 (0)2307/26070-0 > Fax +49 (0)2307/17050 Internet: www.emtest.com > E-mail: info.emtest@ametek.de France EM TEST FRANCE > Le Trident - Parc des Collines > Immeuble B1 - Etage 3 > 36, rue Paul Cézanne > 68200 Mulhouse > France Téléphone +33 (0)389 31 23 50 > Fax +33 (0)389 31 23 55 Internet: www.emtest.fr > E-mail: info@emtest.fr USA / Canada AMETEK Compliance Test Solutions > 52 Mayfield Ave. > Edison > NJ 08837 Téléphone +1 (732) 417-0501 Internet: www.emtest.com > E-mail: sales.emtest@ametek.com Chine E & S Test Technology Limited > Rm 913, Leftbank > No. 68 Bei Si Huan Xi Lu > Haidian District > Beijing 100080 > P.R. China Téléphone +86 (0)10 82 67 60 27 > Fax +86 (0)10 82 67 62 38 Internet: www.emtest.com > E-mail: info@emtest.com.cn République de Corée EM TEST Korea Limited > #405 > WooYeon Plaza > #986-8 > YoungDeok-dong > Giheung-gu > Yongin-si > Gyeonggi-do > Korea Téléphone +82 (31) 216 8616 > Fax +82 (31) 216 8616 Internet: www.emtest.co.kr > E-mail: sales@emtest.co.kr Pologne EM TEST Polska > ul. Ogrodowa 31/35, 00-893 Warszawa > Polska Téléphone +48 (0)518 64 35 12 Internet: www.emtest.com/pl > E-mail: info_polska.emtest@ametek.de Les informations sur l\'étendue de la livraison, la présentation visuelle et les données techniques correspondent à l\'état de développement du produit au moment de la mise en circulation de la fiche technique. Les données techniques sont susceptibles de changement sans préavis. www.emtest.com EM TEST > PAGE 5/5