Information security guidelines



Similar documents
Preparing BD Systems for Data Migration. Summary of the Upgrade Process on page 6. Copying User Data Files onto an Upgraded System on page 7

Windows OS Security/Critical Patch List for BD Workstations

White Paper. BD Assurity Linc Software Security. Overview

Windows OS Security/Critical Patch List for BD Workstations

Symantec AntiVirus Corporate Edition Patch Update

Security Guide for the BD Remote Instrument Support Solution BD Biosciences workstations

ReadySHARE Printer. Easy to Set Up: Instructions. 350 East Plumeria Drive San Jose, CA USA

Dell Statistica Statistica Enterprise Installation Instructions

Sophos Anti-Virus for NetApp Storage Systems startup guide. Runs on Windows 2000 and later

Desktop Release Notes. Desktop Release Notes 5.2.1

Sophos Computer Security Scan startup guide

Sophos for Microsoft SharePoint startup guide

Getting started. Symantec AntiVirus Corporate Edition 8.1 for Workstations and Network Servers

McAfee Optimized Virtual Environments - Antivirus for VDI. Installation Guide

Sophos Anti-Virus standalone startup guide. For Windows and Mac OS X

Installation Guide for Workstations

Juris Installation / Upgrade Guide

Symantec Backup Exec TM 11d for Windows Servers. Quick Installation Guide

System Planning, Deployment, and Best Practices Guide

SOS Suite Installation Guide

Sophos Anti-Virus for NetApp Storage Systems startup guide

Upgrade to Webtrends Analytics 8.7: Best Practices

Upgrade: SAP Mobile Platform Server for Windows SAP Mobile Platform 3.0 SP02

WhatsUp Gold v16.2 Installation and Configuration Guide

Windows Small Business Server 2003 Upgrade Best Practices

SQL 2014 Configuration Guide

Reporting for Contact Center Setup and Operations Guide. BCM Contact Center

Sophos Endpoint Security and Control standalone startup guide

Upgrade Guide. CA Application Delivery Analysis 10.1

Dell Recovery Manager for Active Directory 8.6. Quick Start Guide

Sophos Enterprise Console server to server migration guide. Product version: 5.1 Document date: June 2012

TANDBERG MANAGEMENT SUITE 10.0

System Requirements for LAW PreDiscovery Software ( LAW ) LAW PreDiscovery Software Installation Guide

Sophos Enterprise Console server to server migration guide. Product version: 5.2

Security Industry Market Share Analysis

PrintFleet Local Beacon

UFR II Driver Guide. UFR II Driver Ver ENG

Getting started. Symantec AntiVirus Corporate Edition. About Symantec AntiVirus. How to get started

Dell One Identity Cloud Access Manager Installation Guide

Copyrights, Legal Notices, Trademarks and Servicemarks

SMART Vantage. Installation guide

Abila MIP. Installation User's Guide

Selected Windows XP Troubleshooting Guide

Upgrade Guide BES12. Version 12.1

Symantec Backup Exec 2010 R2. Quick Installation Guide

Diamond II v2.3 Service Pack 4 Installation Manual

Ajera 7 Installation Guide

Quick Install Guide. Lumension Endpoint Management and Security Suite 7.1

System Management. What are my options for deploying System Management on remote computers?

Sophos Anti-Virus for NetApp Storage Systems user guide. Product version: 3.0

FileMaker 8. Installing FileMaker 8 ODBC and JDBC Client Drivers

ilaw Installation Procedure

LVS Troubleshooting Common issues and solutions

FreeFlow Accxes Print Server V15.0 August P Xerox FreeFlow Accxes Print Server Drivers and Client Tools Software Installation Guide

Symantec Mail Security for Domino

Configuring Symantec AntiVirus for Hitachi High-performance NAS Platform, powered by BlueArc

Reconfiguring VMware vsphere Update Manager

Networking Best Practices Guide. Version 6.5

Oracle WebCenter Content Service for Microsoft Exchange

Symantec Event Collector 4.3 for Microsoft Windows Quick Reference

Reconfiguring VMware vsphere Update Manager

KofaxExpress. Installation Guide

VERITAS Backup Exec TM 10.0 for Windows Servers

Installation Instruction STATISTICA Enterprise Small Business

If you are not using a network environment (i.e. USB connection only) If you are using the printer in a network environment

Attix5 Pro Storage Platform

Pre-Installation Instructions

ESET REMOTE ADMINISTRATOR. Migration guide

Any system currently running the Schneider Electric MBX Driver Suite or any activated Cyberlogic software suite.

Dialogic System Release 6.0 PCI for Windows

GFI Product Manual. Version 6.0. Getting Started Guide

Contents. 1 Introduction Purpose Target audience Overview... 3

Important. Please read this User s Manual carefully to familiarize yourself with safe and effective usage.

Sentinel Installation Guide

Landscape Design and Integration. SAP Mobile Platform 3.0 SP02

Remote Console Installation & Setup Guide. November 2009

FAS Asset Accounting FAS CIP Accounting FAS Asset Inventory SQL Server Installation & Administration Guide Version

Dell Statistica. Statistica Document Management System (SDMS) Requirements

STATISTICA VERSION 12 STATISTICA ENTERPRISE SMALL BUSINESS INSTALLATION INSTRUCTIONS

Getting started. Symantec AntiVirus Business Pack. About Symantec AntiVirus. Where to find information

Windows SharePoint Services Installation Guide

Sophos for Microsoft SharePoint Help. Product version: 2.0

Upgrading a computer to Windows 10 with PetLinx

Feith Rules Engine Version 8.1 Install Guide

Ascent Capture Internet Server

Getting started. Symantec AntiVirus Corporate Edition. About Symantec AntiVirus. How to get started

Core Protection for Virtual Machines 1

Symantec Mail Security for Microsoft Exchange Management Pack Integration Guide

Getting Started. Symantec Client Security. About Symantec Client Security. How to get started

Table of Contents. FleetSoft Installation Guide

CS WinOMS Practice Management Software Server Migration Help Guide

SMALL BUSINESS EDITION. Sophos Control Center startup guide

Spector 360 Deployment Guide. Version 7.3 January 3, 2012

Sophos Anti-Virus for Mac OS X network startup guide. For networked Macs running Mac OS X

Technical Brief for Windows Home Server Remote Access

Contents Notice to Users

Altiris Patch Management Solution for Windows 7.1 from Symantec Release Notes

DeviceAnywhere Enterprise. ios Device Onboarding Guide

Transcription:

Information security guidelines BD Biosciences workstations 8/2014 This document includes the following topics: About this guide (page 2) Software policies (page 3) Virus protection setup and operation (page 4) Microsoft Windows update guidelines (page 9) Microsoft Windows limited user account settings (page 11) Software firewall and proxy settings (page 14) Removable media guidelines (page 17)

2 Information security guidelines About this guide Overview This guide is intended to provide recommendations to customers regarding security on BD Biosciences workstations. This includes installation and setup of antivirus and management of Microsoft Windows security updates, hotfixes, limited user account settings, firewall settings, and removable media guidelines. Who should read this guide All IT system administrators of BD instrument workstations should read this guide. Guide contents This guide describes: Our recommendations, responsibilities, warranty, and liability regarding the installation and maintenance of virus protection and Windows security updates and hotfixes. Our policy on the setup and use of virus protection on BD workstations that have BD FACSDiva, BD FACSCanto clinical, BD FACS SPA, BD FACSArray, or BD FACSuite installed. Our policy on how often BD Biosciences reviews and releases a list of Windows security updates and hotfixes that have minimal impact on BD workstations with BD FACSDiva, BD FACSCanto clinical, BD FACS SPA, BD FACSArray, or BD FACSuite installed. Our policy on the management of Windows limited user account settings on BD workstations that have BD FACSDiva, BD FACSCanto clinical, BD FACS SPA, BD FACSArray, or BD FACSuite installed.

Information security guidelines 3 Our policy on the management of firewall settings on BD workstations that have BD FACSDiva, BD FACSCanto clinical, BD FACS SPA, BD FACSArray, or BD FACSuite installed. Our policy on the use and management of removable media on BD workstations that have BD FACSDiva, BD FACSCanto clinical, BD FACS SPA, BD FACSArray, or BD FACSuite installed. Where to store this guide Store this guide near your BD workstation for reference. Software policies Introduction This topic describes BD Biosciences policies concerning responsibility, warranty, and liability. It also explains the testing of the information security guidelines using virus protection. Responsibility, warranty, and liability BD Biosciences delivers and workstations that are intended for running the instruments supplied by BD Biosciences. It is your responsibility to ensure that all workstations are updated with the latest Windows security updates and hotfixes. It is your responsibility to install and maintain Windows security updates and hotfixes. BD Biosciences does not provide any warranty with respect to Windows security updates and hotfixes or their compatibility with BD Biosciences products, nor does BD Biosciences make any representation with respect to the workstation remaining virus-free after installation. BD Biosciences is not liable for any claims related to or resulting from failure to install and maintain Windows security updates and hotfixes.

4 Information security guidelines BD Biosciences does not provide any warranty with respect to virus protection or its compatibility with BD Biosciences products, nor does BD Biosciences make any representation with respect to the workstation remaining virus-free after installation. BD Biosciences is not liable for any claims related to or resulting from failure to install and maintain virus protection. It is your responsibility to ensure that all electronic files (including and transport media) are virus-free. It is your responsibility to install and maintain up-to-date virus protection. We do not make recommendations for a specific brand of virus protection. Testing The guidelines in this document are based on tests performed using Norton Internet Security 2010-2011 virus protection. BD Biosciences cannot claim that future versions of Norton virus protection or virus protection from other vendors will be compatible with these guidelines. Virus protection setup and operation Introduction This topic provides general guidelines for installing and configuring third-party virus protection on BD Biosciences workstations that already have BD FACSDiva, BD FACSCanto clinical, BD FACS SPA, BD FACSArray, or BD FACSuite installed and are running on a supported Microsoft Windows OS. Follow these guidelines to reduce the risk of impacting the performance and functionality of the BD listed in About this guide.

Information security guidelines 5 Installation See the information provided by the third-party virus protection manufacturer for specific installation and user instructions. When installing virus protection, select the Typical or Default installation method. Setup After installing virus protection, set it up as follows: Enable on-access scanning of new files,, and all removable media. Enable on-access scans for unwanted scripts, including Java scripts. Disable any heuristics options, such as finding unknown programs or unknown macro viruses. Exclude the following BD folders from on-access scanning for systems running on Windows XP. Software BD FACS SPA v4.x and earlier running on Windows XP BD FACSArray Files and folders C:\Program Files\BD FACS SPA Software C:\Program Files\BD FACSArray Software C:\Program Files\Common Files\BD C:\Program Files\Java C:\Program Files\Sybase C: or D: \BDDatabase

6 Information security guidelines Software BD FACSDiva v7.0 and earlier running on Windows XP BD FACSCanto clinical v2.4 and earlier running on Windows XP BD FACSMicroCount BD FACSuite Files and folders C:\BDCytometerSetupAndTracking C:\Program Files\BD FACSDiva Software C:\Program Files\Common Files\BD C:\Program Files\Java C:\Program Files\Sybase C: or D: \BDDatabase C:\BDCytometerSetupAndTracking C:\Program Files\BD FACSCanto Software C:\Program Files\Common Files\BD C:\Program Files\Java C:\Program Files\Sybase C: or D: \BDFACSCantoFCSFiles C: or D: \BDDatabase C:\BD FACSMicroCount Or the location where BD FACSMicroCount is installed N/A

Information security guidelines 7 Exclude the following BD folders from on-access scanning for systems running on Windows 7. Software BD FACS SPA v5.0 and later running on Windows 7 BD FACSDiva v8.0 and later running on Windows 7 BD FACSCanto clinical v3.0 and later running on Windows 7 BD FACSuite Files and folders C:\Program Files\BD FACS SPA Software C:\ProgramData\BD\FACS SPA C:\BD\FACS SPA C:\Program Files\BD FACSDiva Software C:\Program Files\Java C:\Program Files\ SQL Anywhere 12 C: or D: \BDDatabase C:\ProgramData\BD\FACSDiva\ C:\ProgramData\BD\Shared\ C: or D: \BD\FACSDiva\CST\ C:\Program Files\BD FACSCanto Software C:\ProgramData\BD\FACSCanto C: or D: \BD\FACSCanto C: or D: \BDFACSCantoFCSFiles C:\Program Files\Java C:\Program Files\SQL Anywhere 12 C:\Program Files\BD FACSDiva Software\CST C:\ProgramData\BD\FACSDiva\CST C:\ProgramData\BD\Shared C: or D: \BD\FACSDiva\CST\ C\:ProgramData\BD\FACSuite

8 Information security guidelines Schedule full-system scanning to include all files and folders (including BD files and folders). Schedule scanning to occur when the system is not in use. The virus protection s directory scan is processorintensive and could adversely affect the performance of BD if run simultaneously. Caution! BD Biosciences is not responsible for data corruption or loss if full-system scanning occurs while BD is running. Schedule automatic updates of the virus definition files during times when the instrument is not in use. To prevent unnecessary scanning by the on-access scanner, do not insert removable storage media or try to access information on such media while BD is running. Virus detection Installing BD Upgrading virus protection If the detects a virus: Move all infected files to a quarantine folder. If BD becomes infected, reinstall it. Consult your IT department about whether to delete the infected files. Before installing BD, temporarily disable virus protection. Enable virus protection after you have finished installing BD. Upgrading virus protection might cause several changes in the configuration of the and the exclusion list for the on-access scanner. We suggest that you verify that the recommended configuration settings and exclusion list have not been altered by the upgrade.

Information security guidelines 9 Troubleshooting If you follow these guidelines, but the performance and functionality of BD is still affected, contact your virus protection vendor for additional -specific guidelines. Microsoft Windows update guidelines Introduction This topic describes how to manage Windows security updates and hotfixes on BD Biosciences workstations without affecting the performance or functionality of BD Biosciences. Applicable BD Windows security updates and hotfixes reviewed by BD are compatible with the following BD Biosciences : BD FACSDiva (v5.0 or later) BD FACSCanto clinical (v2.2 or later) BD FACS SPA (v3.0 or later) BD FACSArray (v1.0.4) BD FACSuite (v1.0 or later) Before you begin Contact your company s IT system administrator for the download and installation of Windows security updates and hotfixes on workstations.

10 Information security guidelines Installing updates and hotfixes When installing Windows security updates or hotfixes: We recommend that you turn off the automatic update feature of Windows Update on the workstation. BD Biosciences reviews and updates a list of the newly released Windows security updates and hotfixes from Microsoft. Only those patches that have minimal impact on BD Biosciences are contained in this list. Patches that have a more significant impact on performance will be excluded until we can properly support them. We recommend downloading this document on a monthly basis to ensure that you have the most current list of Windows security updates and hotfixes reviewed by BD. We recommend that you work with your IT system administrator to manually update your workstations based on the current BD Biosciences list of reviewed Windows security updates and hotfixes. Only update from an official vendor site. See microsoft.com for the latest Windows security updates and hotfixes. See bdbiosciences.com for the latest list of Windows security updates and hotfixes reviewed for installation on BD Biosciences workstations. Your IT system administrator should test and approve the Windows security updates and hotfixes and reject undesired updates as appropriate for your company.

Information security guidelines 11 Auto-Update for Java Do not enable Auto-Update in Java v6. When Auto-Update in Java v6 is enabled, it automatically updates Java by installing Java v7 and uninstalling Java v6, causing issues with BD FACSDiva. Microsoft Windows limited user account settings Introduction This topic describes how to manage the security permission settings for Windows limited user accounts. Your company s IT system administrator is responsible for ensuring that the Windows limited user accounts have full access permissions to the settings listed in these guidelines. Also, we state our recommendations for tasks that should not be delegated to limited user accounts. Security permission settings for registry keys Registry key settings are applicable to Windows XP only. Windows limited user accounts must have full access to the following registry keys: HKEY_LOCAL_MACHINE\Software\BD HKEY_LOCAL_MACHINE\Software\BDExport Security permission settings for driver files If the workstation is connected to a BD FACSAria flow cytometer, the Windows limited user accounts must have full access to the following driver files: C:\Windows\System32\ipl.dll C:\Windows\System 32\iplw7.dll C:\Windows\System 32\Cpuinf32.dll Security permission setting for user groups Windows limited user accounts must be members of the BUILTIN\Users Windows Group to run BD FACSuite.

12 Information security guidelines Security permission settings for folders Windows limited user accounts must have full access to the following folders. See the following table for systems running on Windows XP. Software BD FACS SPA v4.x and earlier running on Windows XP BD FACSArray BD FACSDiva v7.0 and earlier running on Windows XP BD FACSCanto clinical v2.4 and earlier running on Windows XP BD FACSuite Folders C:\Program Files\BD FACS SPA Software C:\Program Files\BD FACSArray System Software C:\Program Files\Sybase C: or D: \BDDatabase C:\BDCytometerSetupAndTracking C:\Program Files\BD FACSDiva Software C:\Program Files\Common Files\BD C:\Program Files\Sybase C: or D: \BDDatabase C:\BDCytometerSetupAndTracking C:\Program Files\BD FACSCanto Software C:\Program Files\Common Files\BD C:\Program Files\Sybase C: or D: \BDFACSCantoFCSFiles C: or D: \BDDatabase N/A

Information security guidelines 13 See the following table for systems running on Windows 7. Software BD FACS SPA v5.0 and later running on Windows 7 BD FACSDiva v8.0 and later running on Windows 7 BD FACSCanto clinical v3.0 and later running on Windows 7 Folders C:\Program Files\BD FACS SPA Software C:\ProgramData\BD\FACS SPA C:\BD\FACS SPA C:\Program Files\BD FACSDiva Software C:\Program Files\Java C:\Program Files\ SQL Anywhere 12 C: or D: \BDDatabase C:\ProgramData\BD\FACSDiva\ C:\ProgramData\BD\Shared\ C: or D: \BD\FACSDiva\CST\ C:\Program Files\BD FACSCanto Software C:\ProgramData\BD\FACSCanto C: or D: \BD\FACSCanto C: or D: \BDFACSCantoFCSFiles C:\Program Files\Java C:\Program Files\SQL Anywhere 12 C:\Program Files\BD FACSDiva Software\CST C:\ProgramData\BD\FACSDiva\CST C:\ProgramData\BD\Shared C: or D: \BD\FACSDiva\CST\

14 Information security guidelines Software BD FACSMicroCount BD FACSuite Folders All folders and subfolders in the following location: C:\BD FACSMicroCount Or the location where BD FACSMicroCount is installed. All folders and subfolders in the following: C:\ProgramData\BD\FACSuite Delegation of database restore task Limited user accounts do not have sufficient administrative rights to restore the database in BD FACSDiva, BD FACSArray, and BD FACSuite. We recommend that the lab administrator or IT group perform database restore on BD Biosciences. Note that the initial release of BD FACSuite has a limitation that will only allow members in the BUILTIN\Administrator Windows Group to perform a database backup with the backup utility. Software firewall and proxy settings Introduction This topic describes how to set the firewall exclusions and proxy settings for the workstation. Software firewall settings Do not enable the firewall on the network card that connects the workstation to the instrument.

Information security guidelines 15 Network card settings for Windows XP On the network card that connects the workstation to your network, allow access to the following applications on Windows XP. Application Adaptive Server Anywhere ISQL Sybase Central ISQ Java BD FACSLink File path C:\Program Files\Sybase\SQL Anywhere 9\win32\dbisqlg.exe C:\Program Files\Sybase\Shared\Sybase Central 4.3\win32\scjview.exe C:\Program Files\BD FACSDiva Software\CST\ISQ.exe C:\WINDOWS\system32\java.exe File and printer sharing Network card settings for Windows 7 On the network card that connects the workstation to your network, allow access to the following applications on Windows 7. Application Sybase Central ISQ Java BD FACSLink File path C:\Program Files\SQL Anywhere 12\BIN32\scjview.exe C:\Program Files\BD FACSDiva Software\CST\ISQ.exe C:\WINDOWS\system32\java.exe File and printer sharing TCP sockets settings TCP sockets settings are applicable to Windows XP and Windows 7.

16 Information security guidelines There should be no rules blocking local access to the following TCP sockets. Application TCP sockets Sybase 1498, 2638 Proxy settings If the BD workstation is connected to an internal network, and you are using a proxy server, instrument IP requests might get directed to the proxy server. To avoid this, configure exceptions for internal instrument IP addresses. If you do not have your proxy server or the appropriate exception configured correctly, you might not be able to access the instrument from the application. Make sure to configure the proxy server and the exceptions in Internet Explorer. 1. Enable Bypass server proxy for local addresses. 2. In the Exceptions field, enter the IP address of the internal instrument network, for example 192.168.*.*.

Information security guidelines 17 Removable media guidelines Introduction This topic describes BD Biosciences guidelines for the use of removable media. Virus protection Set up your virus protection to enable on-access scanning and scheduled full-system scanning of all removable media. To prevent adverse performance of BD, perform both the onaccess scanning and scheduled full-system scanning when you are not running any BD. See Virus protection setup and operation for detailed information. Restricting user access BD Biosciences workstations require the use of one or more USB security keys to function properly. You should not disable the USB ports on your BD Biosciences workstations. If you want to restrict users from accessing removable media on BD Biosciences workstations, follow Microsoft s recommendations to prevent users from connecting to USB storage devices. Go to support.microsoft.com. For example, you can search for Microsoft knowledge base 823732 to find the procedure to prevent users from connecting to USB storage devices for Windows XP.

Copyrights 2014, Becton, Dickinson and Company. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, stored in retrieval systems, or translated into any language or computer language, in any form or by any means: electronic, mechanical, magnetic, optical, chemical, manual, or otherwise, without prior written permission from BD Biosciences. The information in this document is subject to change without notice. BD Biosciences reserves the right to change its products and services at any time to incorporate the latest technological developments. Although this guide has been prepared with every precaution to ensure accuracy, BD Biosciences assumes no liability for any errors or omissions, nor for any damages resulting from the application or use of this information. BD Biosciences welcomes customer input on corrections and suggestions for improvement. Trademarks Java is a trademark of Oracle and/or its affiliates. Microsoft and Windows are registered trademarks of Microsoft Corporation in the Unites States and/or other countries. Norton is a trademark of Symantec Corporation or its affiliates in the US and other countries. BD, BD Logo and all other trademarks are property of Becton, Dickinson and Company. 2014 BD Regulatory information BD cytometers are Class 1 Laser Products. bdbiosciences.com 23-14533-01 8/2014 Becton, Dickinson and Company BD Biosciences 2350 Qume Drive San Jose, CA 95131 USA Tel 877.232.8995 Fax 408.954.2347 ResearchApplications@bd.com BD Biosciences European Customer Support Tel +32.2.400.98.95 Fax +32.2.401.70.94 help.biosciences@europe.bd.com