FITMASTER Software for data review, analysis and fitting



Similar documents
Manual FITMASTER Analysis software

PATCHMASTER Multi-channel data acquisition software

Quick Reference Manual

10 Thomas, Irvine, CA USA Tel: (949) Fax: (949) Toll Free: (800) 23 FUTEK

ChromQuest 5.0 Chromatography Data System

KaleidaGraph Quick Start Guide

Generating ABI PRISM 7700 Standard Curve Plots in a Spreadsheet Program

ADINSTRUMENTS. making science easier. LabChart 7. Student Quick Reference Guide

0 Introduction to Data Analysis Using an Excel Spreadsheet

ValveLink Mobile Software

Building a Simulink model for real-time analysis V Copyright g.tec medical engineering GmbH

Petrel TIPS&TRICKS from SCM

Lab 1: Introduction to PSpice

Multi Channel software

SW43W. Users Manual. FlukeView Power Quality Analyzer Software Version 3.20 onwards

Dash 18X / Dash 18 Data Acquisition Recorder

GeoGebra Statistics and Probability

VIRTUAL DESKTOP COMPANION SOFTWARE FOR MAC

Corrosion Data Management Software Version 3.1.3

Scatter Plots with Error Bars

SpecLine Offline Spectroscopy Analysis Software SPECLINE-P/SPECLINE-U. Installation and Operation Manual Document Number

Drawing a histogram using Excel

Scientific Graphing in Excel 2010

Configuring a Macintosh Laptop to Use Multiple Displays

Topography of an Origin Project and Workspace

Exploring Relationships between Highest Level of Education and Income using Corel Quattro Pro

Gerrit Stols

Using Excel for Handling, Graphing, and Analyzing Scientific Data:

EXO4 Web Server User Guide

INTRODUCTION TO EXCEL

CNCTRAIN OVERVIEW CNC Simulation Systems

The software beyond the climatic. Environment simulation

EXPERIMENT NUMBER 5 BASIC OSCILLOSCOPE OPERATIONS

Period04 User Guide. Abstract. 1 Introduction. P. Lenz, M. Breger

InfoPrint 4247 Serial Matrix Printers. Remote Printer Management Utility For InfoPrint Serial Matrix Printers

How To Use A High Definition Oscilloscope

EPSON Stylus. Start Here

Experiment P-17 Magnetic Field Strength

Navios Quick Reference

Dash 8Xe / Dash 8X Data Acquisition Recorder

MI Software. Innovation with Integrity. High Performance Image Analysis and Publication Tools. Preclinical Imaging

Universal Simple Control, USC-1

STATGRAPHICS Online. Statistical Analysis and Data Visualization System. Revised 6/21/2012. Copyright 2012 by StatPoint Technologies, Inc.

PRODUCT DATA. PULSE Data Manager Types 7767-A, -B and -C. Uses and Features

(MODULES PowerSINE, PowerCV, PowerSTEP, PowerPULSE, PowerCORR)

CATC Multi-Protocol Analyzer (MPA) Reference Manual

Plots, Curve-Fitting, and Data Modeling in Microsoft Excel

EE 242 EXPERIMENT 5: COMPUTER SIMULATION OF THREE-PHASE CIRCUITS USING PSPICE SCHEMATICS 1

User Manual CROMLAWATCH. Data Logging Software. Version 1.6. For use with Color Sensors CROMLAVIEW CR100 CROMLAVIEW CR200 CROMLAVIEW CR210

CAN & LIN Development Tool CLDT1004 HS CAN

EDM SOFTWARE ENGINEERING DATA MANAGEMENT SOFTWARE

Controllable Space Phaser. User Manual

Manual for simulation of EB processing. Software ModeRTL

THE CERN/SL XDATAVIEWER: AN INTERACTIVE GRAPHICAL TOOL FOR DATA VISUALIZATION AND EDITING

WEB TRADER USER MANUAL

Lab 3: Introduction to Data Acquisition Cards

Welcome to Vernier LabQuest Viewer Software v1.0 Note: LabQuest Viewer Features Set up LabQuest 2 to work with LabQuest Viewer software via Wi-Fi

TWIN-TURBINE CENTRIFUGAL COMPRESSOR

Signature Viewer 4.1 Operator s Manual

Classroom Tips and Techniques: The Student Precalculus Package - Commands and Tutors. Content of the Precalculus Subpackage

LEGENDplex Data Analysis Software

Quickstart for Desktop Version

XCal-View user manual

PRODUCT DATA. PULSE WorkFlow Manager Type 7756

Keysight 14585A Control and Analysis Software

VIRTUAL DESKTOP COMPANION SOFTWARE FOR WINDOWS

SoundLAB Software Download Software from the Bogen website:

Gestation Period as a function of Lifespan

13-1. This chapter explains how to use different objects.

Microsoft Excel. Qi Wei

The software solution to complete your flow monitoring program

Postscript Printer Descriptions Installation and Release Notes

Software Manual - Part IIIa: MARS Data Analysis. Version 2.10

Ovation Operator Workstation for Microsoft Windows Operating System Data Sheet

Using a USB Flash Drive to Back Up Your Data Files on a Mac Computer

Instructions for Use. CyAn ADP. High-speed Analyzer. Summit G June Beckman Coulter, Inc N. Harbor Blvd. Fullerton, CA 92835

Using Microsoft Excel to Plot and Analyze Kinetic Data

BD CellQuest Pro Software Analysis Tutorial

STEELSERIES FREE MOBILE WIRELESS CONTROLLER USER GUIDE

Experiment #1, Analyze Data using Excel, Calculator and Graphs.

Creating Forms with Acrobat 10

Power Log PC Application Software

Xerox 700 Digital Color Press with Integrated Fiery Color Server. Utilities

Legal Notes. Regarding Trademarks KYOCERA Document Solutions Inc.

Transmitter Interface Program

GeoGebra. 10 lessons. Gerrit Stols

Using Network Manager to Collect and Graph Data from Network Devices

NorthClark Computing, Inc. Bill of Material and Parts Master Maintenance. Administrator s Guide

Chapter 4 Creating Charts and Graphs

Using Excel (Microsoft Office 2007 Version) for Graphical Analysis of Data

TeamSpot 3. Introducing TeamSpot. TeamSpot 3.1 (rev. 12 December 2006)

Technical Information

Numerical Parameters Analysis of Boonton 4540 Peak Power Meter

Datalogger Graph Software Help

Star t Here. Epson Stylus Photo RX620. Unpack and Assemble. 1 Make sure you have all the parts shown here. If any parts are missing,

MestRe-C User Guide Megan Bragg 04/14/05

VisiSens AnalytiCal 2 Software

Select Correct USB Driver

Hosted Call Recorder Guide. Rev A (21/11/14)

Chapter 32 Histograms and Bar Charts. Chapter Table of Contents VARIABLES METHOD OUTPUT REFERENCES...474

Transcription:

Electrophysiology Electrochemistry FITMASTER Software for data review, analysis and fitting FITMASTER is the ideal software for analysis of electrophysiological data. If you believe your job is to make new discoveries... discover FITMASTER: The software FITMASTER is a tremendous step forward in the development of HEKA s analysis software. FITMASTER contains all advantages of its predecessor PULSEFIT... data review analysis and fitting of data traces fit of analysis results export of data and fit results... but is even further advanced by virtue of... more fit functions merging results from different experiments analysis of train-type data support of PATCHMASTER s data structure clipboard support convenient graph scaling HEKA provides the finest instruments today to achieve the needed progress of tomorrow

Powerful data analysis Key Features (Part I) FITMASTER features analysis and fitting routines for electrophysiological data. Analysis can be performed on the levels of sweeps/traces and series. Besides standard fit functions such as Polynomials, Exponentials, Gaussians, and Boltzmanns, tailored functions to fit e.g. whole-cell current traces according to Hodgkin&Huxley gating formalism, current-voltage relationships and dose-response curves allow publication-proof analysis of your data. Don t forget: FITMASTER is the only electrophysiological data analysis program featuring the Simplex fitting algorithm to guarantee the highest speed and performance. FITMASTER, the second member of the PATCHMASTER software family, was designed to fully support the extended PATCHMASTER data structure. It directly makes available the analysis functions you already know from HEKA s PULSEFIT software. Fitting Available fit functions Functions TraceFit SeriesFit OnlineAnalysis Polynomial Exponential 1-Exponential Hodgkin-Huxley Gaussian RiseTime Measure Boltzmann Exp(x-x0)^n Dose-Response Current-Voltage Furthermore, FITMASTER includes many new features allowing analysis of the more complex data recorded or pre-analyzed by PATCHMASTER. New features, such as the work buffer concept, make analysis with FITMASTER even more powerful. The functions can be displayed, providing information about the underlying math and the status of the fit parameters, i.e. whether a parameter is constant or variable. The variable parameters are identified according to whether they are linear or non-linear. Simplex fit TraceFit and SeriesFit use Simplex fitting algorithm to guarantee high speed and performance. The settings for the simplex fit routine can be set separately for TraceFit and SeriesFit. Fit status The status of the fitting procedure is displayed: fitting, converged, max. iterations, break. Start values The start values for the fit functions can be specified, stored and loaded later on to guarantee identical initial conditions for different data traces. Manual fitting A fit function can be calculated and drawn to the data trace corresponding to parameters manually entered by the user. Picture front page: Cut through the retina. Courtesy of Max Planck Institute for Brain Research, Frankfurt, Germany

Key Features (Part II) TraceFit Complex analysis functions Even complex mathematical expressions can be analyzed with the Online Analyis and then processed with SeriesFit in FITMASTER. Online methods created with PATCHMASTER can be used in FITMASTER. Multiple analyses TraceFit supports the analysis and the storage of results from multiple functions for a given series. A set of results for a given series, for example, can consist of parameters from different analysis and fit functions or form results retrieved from different segments of a trace. Graphing in SeriesFit The SeriesFit graph can be scaled and modified in many ways such as changing the colors, tics, scaling of the axes etc. In addition, the axis range can now be defined as fixed or auto for minimum and maximum as well as X- and Y-axis separately. The scale range in the auto mode can be based either on all data points or on the active, i.e. non-skipped, data points only. The data in the graph can be offset or normalized easily. Mouse actions on the SeriesFit graph By clicking of individual data points in the SeriesFit graph, the number and value is shown in the notebook. Also toggling of the skip status can be performed by a mouse click. Zoom for fit When executing data fits in TraceFit, data sections of interest can be zoomed automatically to provide an optimal view necessary to decide upon the quality of the fit. Cyclic analysis Performs multiple analyses on a single data trace. Useful to analyze responses to tetanus stimulation or other cyclic high speed stimulation. SeriesFit Mathematical preprocessing Results from single or multiple analyses can be compiled in a work buffer before being processed by SeriesFit. This way, data originating from different series can be merged (appended) for later analysis. Work buffer math functions In addition to appending SweepFit results to the analysis work buffer, FITMASTER also allows data with identical X-references to be processed. One can form e.g. the average of multiple results. Such averaged data are then shown with or without error bars and a fit function can be fit to the mean data. Math functions allows some basic mathematical functions average, +,, *, / to be performed between data sets. In addition, the content of the work buffer can be processed with the functions invers, square, sqrt, ln, exp, + const, - const, * const, / const. Work buffer statistics The mean and standard deviation of the entire work buffer content are shown at the bottom of the columns at any time. Data sorting Data in the work buffer can be sorted according to their X- or Y- values. Skipped data points Data points from the work buffer can be omitted from analysis. Results from non-converged fits in TraceFit are automatically marked as skipped. Background trace Multiple background traces can be stored and overlaid to the SeriesFit graph. Compatibility Runs on Windows 98 / NT4.0 / 2000 / XP (requires a parallel printer port on Windows computers) and on Mac OS 9 and Mac OS X (requires a USB port on Macintosh computers). FITMASTER can read sweep data recorded with PATCHMASTER and PULSE or generated with PULSETOOLS or PULSESIM. Export Data export Data and fits of the TraceFit and SeriesFit can be exported into ASCII and IgorPro format. The export mode can be configured to customize output. Clipboard support Fit parameters in TraceFit as well as in SeriesFit can be sent to the clipboard with a single mouse click and transferred to other programs easily. Related Products PATCHMASTER Multi-channel stimulation/acquisition and analysis software package for Windows and Mac OS. PATCHMASTER PRO Multi-channel stimulation/acquisition and analysis software package for Windows and Mac OS with support of a set of Good Lab Practice (GLP) standards for data acquisition and handling, as established by the Food and Drug Administration (FDA) (21CFR Part 11). PULSETOOLS Software for data reorganization, editing and averaging. Amplitude histograms and noise analysis. PULSESIM Modeling and simulation of data based on kinetic schemes or discrete Markov models.

TraceFit: Versatile tools for analysis of electrophysiological data Analysis Control: Shows the analysis under study and indicates the number of parameters analyzed. Trace Controls: Trace and segment number can be specified for the analysis. Cyclic Analysis allows to be performed multiple analyses in a trace, e.g. to analyze responses to tetanus stimulation. Cursors can be defined here or retrieved from an Online Analysis function. TraceFit Controls: Buttons for the control of fits to raw data traces. Auto Fit performs a fit on all sweeps of a series. TraceFit Function: A fit function can be selected and the parameters to be stored can be marked. All fit functions can be displayed and constant, linear and non-linear parameters can easily be distinguished by color. The use-dependent inactivation of sodium channels is analyzed. The Cyclic Analysis feature allows multiple responses in a data trace to be automatically analyzed. The decay of an individual sodium current is analyzed. For fitting of the double-exponential decay of the ionic current, the display is automatically zoomed to the region of interest. The theoretical curve is superimposed upon the raw data.

SeriesFit: Data merging and publication-proof analysis Data and Parameter Selection: The series and the analyses for processing in SeriesFit can be selected. A pair of X and Y parameters determined by TraceFit can then be specified for the analysis. SeriesFit Function: A fit function can be selected and the parameters to be exported can be marked. By pressing Fit Type the fit function is displayed. Initial starting parameters can be stored, loaded or set to default values. Waves Control: Results of the TraceFit can be added to the work buffer. The content of the work buffer can be displayed in the SeriesFit graph. A spread sheet shows the individual data entries as well as the mean value and the standard deviation. Single data points can be edited. The sort function allows sorting the buffer content with respect to the X or Y wave. Multiple waves, for example, can be averaged in the work buffer and the mean values with error bars can be displayed in the SeriesFit graph. Graph Control: Data presentation in the SeriesFit graph can be adjusted. Auto and fixed scaling can be specified for X and Y axis separately. Data display can be offset and normalized easily. Multiple background traces can be stored and superimposed upon the data. Data and fits including errors and fit parameters can be exported. SeriesFit Control: Control buttons for SeriesFit. Here a Boltzmann function fitted to the average of three analyses and superimposed upon the data. A fit previously stored to the analysis file can be retrieved and displayed.

HEKA Elektronik Dr. Schulze GmbH Wiesenstraße 71 D-67466 Lambrecht/Pfalz Germany Phone Fax Web Site Email +49 (0) 63 25 / 95 53-0 +49 (0) 63 25 / 95 53-50 http://www.heka.com sales@heka.com support@heka.com HEKA Electronics Incorporated 47 Keddy Bridge Road R.R. #2 Mahone Bay, NS B0J 2E0 Canada Phone Fax Web Site Email +1 902 624 0606 +1 902 624 0310 http://www.heka.com nasales@heka.com support@heka.com HEKA Instruments Inc. 33 Valley Road Southboro, MA 01772 USA Phone Fax Web Site Email +1 866 742 0606 (Toll Free) +1 508 481 8945 http://www.heka.com nasales@heka.com support@heka.com General notice: Product names used herein are for identification purposes only and may be trademarks of their respective owners. HEKA disclaims any and all rights in those marks. We reserve the right to effect technical changes as development progresses. Special versions are available on request. Further technical data are provided by a detailed description, which is available on request. A guarantee of one year applies on all instruments. VKRFM1/2