SOP085 - HELLER OVEN SOFTWARE INSTALLATION PROCEDURE. For version 6.2.x.x



Similar documents
64-Bit Compatibility with Micromeritics Applications

Preparing the Windows version of the software for use

Ultra Thin Client TC-401 TC-402. Users s Guide

Internet for Everyone In-Room Instructions January 2011 Version 1.3

Configuring Windows 7 64 bit for AutoVISION

Installation and Connection Guide to the simulation environment GLOBAL VISION

SmartSync Monitor Help

Additional Requirements for ARES-G2 / RSA-G2. One Ethernet 10 Base T/100 Base TX network card required for communication with the instrument.

Guide to Installing BBL Crystal MIND on Windows 7

Ethernet Interface Manual Thermal / Label Printer. Rev Metapace T-1. Metapace T-2 Metapace L-1 Metapace L-2

CMP-102U. Quick Installation Guide

Topaz Installation Sheet

Installation Instruction STATISTICA Enterprise Small Business

Motorola Phone Tools. Quick Start

Magaya Software Installation Guide

Keri USB-A Connection and Configuration

This document details the following four steps in setting up a Web Server (aka Internet Information Services -IIS) on Windows XP:

STATISTICA VERSION 9 STATISTICA ENTERPRISE INSTALLATION INSTRUCTIONS FOR USE WITH TERMINAL SERVER

Configuring the WT-4 for ftp (Ad-hoc Mode)

BASLER ACE QUICK INSTALLATION GUIDE

Enabling Internet Connection Sharing on Windows Enabling ICS On Windows XP As The Host 4 Enabling ICS On Windows XP As The Client 11

Configuring the WT-4 for ftp (Infrastructure Mode)

INFUSION BUSINESS SOFTWARE Installation and Upgrade Guide

Option nv, Gaston Geenslaan 14, B-3001 Leuven Tel Fax Page 1 of 14

3.5 EXTERNAL NETWORK HDD. User s Manual

STATISTICA VERSION 12 STATISTICA ENTERPRISE SMALL BUSINESS INSTALLATION INSTRUCTIONS

Configuring the WT-4 for Upload to a Computer (Infrastructure Mode)

Immotec Systems, Inc. SQL Server 2005 Installation Document

Table of Contents. FleetSoft Installation Guide

Using a simple crossover RJ45 cable, you can directly connect your Dexter to any computer.

Chapter7 Setting the Receiving PC for Direct Upload. Setting the Receiving PC for Direct Upload For Windows For Macintosh...

Before You Begin, Your Computer Must Meet the System Requirements

@ptitude Observer. Installation Manual. Part No Revision G

Internet Guide. Prepared for 55 John Street

Iridium Extreme TM Satellite Phone. Data Services Manual

EXPRESSCLUSTER X for Windows Quick Start Guide for Microsoft SQL Server Version 1

Installation Instruction STATISTICA Enterprise Server

Configuring the WT-4 for Upload to a Computer (Ad-hoc Mode)

Configuring the WT-4 for Upload to a Computer (Ad-hoc Mode)

1-Port Wireless USB 2.0 Print Server Model # APSUSB201W. Quick Installation Guide. Ver. 2A

LPR for Windows 95/98/Me/2000/XP TCP/IP Printing User s Guide. Rev. 03 (November, 2001)

Schneider OS-Loader usage via Ethernet or USB.

1. Installing The Monitoring Software

ENPS-MF1. 1 USB Port. Multifunctional Print Server. Quick Installation Guide V1.0

SEE Electrical Installation Manual

User Manual Network Interface

AcqKnowledge or better for Windows OS (version compatibility varies each release)

Dream Report Version 4.5

HYPERLINK Internet PC setup guide. HYPERLINK Internet support helpdesk at

Installing the KX-P8420 or KX-PS8100 on Windows NT 4.0.

FAQ. How does the new Big Bend Backup (powered by Keepit) work?

3M Occupational Health and Environmental Safety 3M E-A-Rfit Validation System. Version 4.2 Software Installation Guide (Upgrade) 1 P age

Configuring the WT-4 for Upload to a Computer (Infrastructure Mode)

How To Install Database Oasis On A Computer Or Computer (For Free)

new Business Online Technical Troubleshooting Guide

Point of Sale 2015 Enterprise. Installation Guide

Contents. Hardware Configuration Uninstalling Shortcuts Black...29

Configuring the WT-4 for ftp (Ad-hoc Mode)

AXIS Camera Station Quick Installation Guide

Printing Options. Netgear FR114P Print Server Installation for Windows XP

NCD ThinPATH Load Balancing Startup Guide versions and 2.8.1

Moxa Device Manager 2.0 User s Guide

1. TIB388 about the Windows compatibility of all Mutoh devices subdivided in

Release Notes - Installing the Wireless Receiver on a PC.

TL-PS310U Single USB 2.0 Port MFP and Storage Server

Pearl Echo Installation Checklist

Installing and Trouble-Shooting SmartSystems

OPERATION MANUAL. MV-410RGB Layout Editor. Version 2.1- higher

SOFTWARE INSTALLATION INSTRUCTIONS

Multi-Share User Instructions

V.I.P. Kit. Video Insight Pilot Kit. (Video Insight Pilot Kit).

ilaw Installation Procedure

Keystone 600N5 SERVER and STAND-ALONE INSTALLATION INSTRUCTIONS

User s Manual CONTENT. Nano NAS Server for USB storages. 1. Product Information Product Specifications System requirements..

Enterprise Surveillance Manager. Version 5.3 System Administrator s Manual

Thuraya XT-DUAL. Software Upgrade Manual

Application Note phindows Installation

Centurion PLUS CPC4 Download Guide

Metasys System Direct Connection and Dial-Up Connection Application Note

Installation Notes for Outpost Network Security (ONS) version 3.2

Installation Guide for Windows May 2016

F-Secure Online Backup Quick Installation Guide

Network & Internet Installation & Information Guide Fall 2004 Edition. Campus Ethernet For PCs using Windows 2000 & XP

XConsole GUI setup communication manual September 2010.

Monitor Wall 4.0. Installation and Operating Manual

Fiery E100 Color Server. Welcome

TRENDnet. <a trendnet.com"> Quick Installation Guide. Product Warranty Registration

DSL Installation Guide

BASIC INSTRUCTIONS TO CONFIGURE ZYXEL P8701T CPE USING THE WEB INTERFACE

Setting Up Internet Connection Sharing (ICS) on a Server

SATO Network Interface Card Configuration Instructions

Changing Your Cameleon Server IP

User Manual Version p BETA III December 23rd, 2015

Setting Up Your FTP Server

Network Server for Windows. Overview of the Sequencher Network Page 2. Installing Sequencher Server for the First Time Page 3

INSTALLING AND USING ENTEL PROGRAMMER IN WINDOWS 7 Technical Support Bulletin

VirtualXP Users Guide

AcqKnowledge for Windows: Upgrade for 1+MP150s and Domain Network Access or Direct Communication Setup (Domain/Non-domain)

Upgrading from MSDE to SQL Server 2005 Express Edition with Advanced Services SP2

Printer Driver Installation Guide

Transcription:

SOP085 - HELLER OVEN SOFTWARE INSTALLATION PROCEDURE For version 6.2.x.x DATE REV ECN - DESCRIPTION OF CHANGE Initials 02/20/2014 INT ECN 140003-001 TP For version 6.2.x.x Rev. INT Page 1 of 16

Basic PC System requirement: OS: Windows XP/Vista/7 (32bit, Home basic, premium or Professional) Processor speed: preferred 2GHz or more RAM: preferred 4 GB (minimum 1GB for XP) Ethernet (TCP/IP) port: for HC2 controller communication Notes: Make sure to uninstall any existing oven software version before installing new software version. Follow section-iv at the end of this document for uninstalling oven software. On Windows-XP,.Net framework version 3 installation is required prior to oven program installation. I. Oven program installation: 1. Run the setup file from the software installation CD or a drive folder. Installation screens will appear as For version 6.2.x.x Rev. INT Page 2 of 16

2. Click Next > to continue installation 3. Type user name, organization name and click Next > For version 6.2.x.x Rev. INT Page 3 of 16

4. Keep Setup Type as Typical 5. Review the installation settings and click Install. For version 6.2.x.x Rev. INT Page 4 of 16

6. Installation status screen and completion screen will appear. Heller Industries, Inc. 7. Click on Finish to complete installation. For version 6.2.x.x Rev. INT Page 5 of 16

8. Setup program will register heller comm.ocx file to windows registry server. Click OK on the display message. 9. Restart the computer after installation is complete. 10. Before running the Oven Operating Program, Oven Setup Wizard needs to run to configure the oven options. Start > All Programs > Oven Workstation > Oven Setup Wizard, Default user=oven, password=oven. 11. After Setup Wizard is complete, update the HC2 driver version by running C:\Oven\Drivers\Hc2DriverUpdate.exe. Refer HC2 controller driver version check section-iii for more information. For version 6.2.x.x Rev. INT Page 6 of 16

II. Setting up computer IP address: (192.168.10.1) ---------------------------------------------------------------------------------------------------- Notes: Use RJ-45 network patch cable for communication with HC2 controller. Default IP address of main HC2 controller is: 192.168.10.250. This cannot be changed. Set Computer IP address as: 192.168.10.1. Refer Setting up computer IP address section below. To Run the Oven Operating Program in DEMO mode - Change the target in Oven Operating Program desktop shortcut properties to add DEMO as "C:\Oven\Oven Operating Program.exe" DEMO ----------------------------------------------------------------------------------------------------- Note: Following message will be displayed when oven program starts and if computer IP address is not set properly or network cable is not connected or power to HC2 controller is off or HC2 controller is with driver version older than 6.0.0.30. To change computer IP address, refer steps below, 1. Select Network and Sharing Center as Start -> Control Panel -> Network and Sharing Center, double click on the icon. For version 6.2.x.x Rev. INT Page 7 of 16

2. Click on View status for Local Area Connection that is used for connecting to HC2 controller. 3. Click on Properties button to access LAN properties window For version 6.2.x.x Rev. INT Page 8 of 16

4. Highlight/Select Internet Protocol Version 4 (TCP/IPv4) and then click on Properties. For version 6.2.x.x Rev. INT Page 9 of 16

5. By default Obtain an IP address automatically is checked on; change selection to Use the following IP address: and set as: IP address: 192.168.10.1 Subnet mask: 255.255.255.0 Click OK to save changes and close the window. Click OK to close Local Area Connection Properties window. Click Close on Local Area Connection Status window. Exit/Close control panel. For version 6.2.x.x Rev. INT Page 10 of 16

III. HC2 controller driver version check and upgrade: A. HC2 controller driver version check: Note: For example if oven program version 6.2.0.5 is started with older HC2 controller driver/firmware version 6.0.0.36, following message will appear during oven program version 6.2.0.5 startup; Click OK to update the HC2 controller drivers. Driver update program will start automatically. Note that for HC2 controllers with installed driver versions 6.0.0.30 or earlier (4.x.x.x, 5.x.x.x), when oven program version 6.2.0.5 starts, following message will display. In this case click OK and update HC2 drivers manually. For version 6.2.x.x Rev. INT Page 11 of 16

B. Update HC2 drivers manually: Close all programs and make sure oven is not running before performing driver update. Run C:\Oven\Drivers\Hc2DriverUpdate.exe program. Confirm HC2 device IP address is set as 192.168.10.250 for single HC2 configuration or primary HC2 for dual HC2 oven configuration. Click on Query button which will start connection to HC2 controller and list current installed driver versions from the connected HC2 controller. Notes: If windows firewall warning shows up, make sure to allow HC2DriverUpdater.exe for network connection. For ovens with dual HC2, upload secondary HC2 drivers by running C:\Oven\Drivers\Secondary Hc2 Drivers\Hc2DriverUpdate.exe. Confirm secondary HC2 device IP address is set as 192.168.10.251. Make sure no ftp services are running on PC, this will cause network connection error for HC2DriverUpdater program For version 6.2.x.x Rev. INT Page 12 of 16

Once installed drivers are listed, click Upload to start uploading new drivers. Upload process status for each file will be displayed. Upon completion, message will display to reboot the HC2. Click Close to exit driver update program and reboot the HC2. For version 6.2.x.x Rev. INT Page 13 of 16

After finishing update, power cycle HC2 controller by turning off and on main oven power. Check program version and HC2 version when oven program is running. Both versions should match. Oven program version and HC2 version can be checked under Help menu on Oven Operating Program. For example: Single HC2 ovens: Dual HC2 ovens: For version 6.2.x.x Rev. INT Page 14 of 16

IV. Uninstalling older version software: Before uninstalling oven software for an upgrade, oven setup parameters and recipe files need to copy. Setup parameters will be used after installing new software to setup the oven. Make sure oven program is not running during backup or uninstall. Backup Setup Parameters: Run Oven Setup Wizard (Start -> All Programs -> Oven Workstation -> System Setup Wizard) and write down all the setup parameters from all pages of the setup wizard. One easy way is to take a screen shot of all setup pages and popup windows for some options. Press ALT + Print Screen to capture active window or Print Screen to capture complete screen display and then using windows paint program paste the captured image and save as an image. Backup Recipe files: Using Windows Explorer, copy all (or required) recipes from C:\Oven\Recipe Files folder to a storage media or temporary backup folder on the computer. These recipe files need to copy back after new software is installed. Note: recipe files from some of previous version software may not be compatible with newer version software. If old recipes are not compatible, then needs to create these recipes manually. Uninstall existing oven software: 1. Access Control Panel, Start > Control Panel 2. Double click on Programs and Features 3. From the list of installed programs, select Oven Workstation Version 4.x.x.x/5.x.x.x/6.x.x.x. Click on Uninstall button to uninstall program completely. For version 6.2.x.x Rev. INT Page 15 of 16

4. After program is uninstalled, delete C:\Oven folder or rename to some different name. 5. Using windows explorer, search for following files C:\Windows\System32\WIN_HDAC.DLL C:\Windows\System32\Heller comm.ocx And delete if exist. Also make sure that there are no other copies of these (WIN_HDAC.DLL, Heller comm.ocx ) files on C:\ drive. 6. Restart the computer. For version 6.2.x.x Rev. INT Page 16 of 16